WorldWideScience

Sample records for systemic venous return

  1. Models of venous return and their application to estimate the mean systemic filling pressure

    NARCIS (Netherlands)

    Hartog, E.A. den

    2007-01-01

    Mean systemic filling pressure is the equilibrium pressure in the systemic circulation when the heart is arrested and there is no flow. This pressure is a measure of the stressed volume of the systemic circulation and regarded as the driving pressure for the venous return during steady states [1-3].

  2. Total anomalous pulmonary venous return

    Science.gov (United States)

    ... pulmonary venous return, x-ray References Fraser CD, Kane LC. Congenital heart disease. In: Townsend CM Jr, ... 62. Review Date 10/17/2017 Updated by: Michael A. Chen, MD, PhD, Associate Professor of Medicine, ...

  3. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    Science.gov (United States)

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  4. The dynamics of venous return and response to hypervolemia in the toad, Bufo marinus (L.)

    OpenAIRE

    Killorn, Erin E; Toews, Daniel P

    2001-01-01

    Background Venous return from the posterior region of amphibians travels by either two renal portal veins to the kidney or a central abdominal vein that drains into the hepatic portal system. The relative proportions of blood flow in these vessels has never been measured nor has a modification of flow been determined when venous return increases by changes in blood volume during hypervolemia or during increased volume input from the posterior lymph hearts. Results Venous return from the poste...

  5. Venous return curve and its application to assessment of the effect of cardiovascular drugs

    Energy Technology Data Exchange (ETDEWEB)

    Nagashima, Kenshi; Gotoh, Kohshi; Yagi, Yasuo (Gifu Univ. (Japan). Faculty of Medicine) (and others)

    1990-01-01

    In an effort to obtain a venous return curve, occlusion plethysmography with radionuclide was performed in the forearm of 24 patients with various heart diseases. Radionuclide angiocardiography was performed and during the equilibrium phase the region of interest was created over the forearm for repeated venous occlusions. Specific compliance in the vein of the forearm was obtained by drawing the radionuclide count-venous pressure curve from changes in venous pressure and radioactivity of the forearm. Compliance of human systemic veins was then obtained based on some hypotheses. Mean systemic pressure (Pms) was estimated. In addition, right auricular pressure and cardiac output were obtained for drawing part of the venous return curve. In a study of the effect of cardiovascular drugs on the venous return curve, Pms was found to be significantly decreased by the administration of nitroglycerin. Furthermore, systemic venous return curve moved to the leftward. In contrast, nifedipine did not have any influence on Pms in Class I of cardiovascular function; and systemic venous return curve moved clockwise by the administration of the drug. In the case of Class II or III, nifedipine caused the systemic venous return curve to move clockwise with decreasing Pms. (N.K.).

  6. Anomlus pulmonary venous return aaccompanied by normal superior pulmonary veins in the left upper lobe: A case report

    International Nuclear Information System (INIS)

    Kim, Dong Eon; Kang, Min Jin; Lee, Ji Hae; Bae, Kyung Eun; Kim, Jae Hyung; Kang, Tae Kyung; Kim, Soung Hee; Kim, Ji Young; Jeong, Myeong Ja; Kim, Soo Hyun

    2017-01-01

    Partial anomalous pulmonary venous return is a rare congenital pulmonary venous anomaly, in which some of the pulmonary veins drain into the systemic circulation rather than the left atrium. Many variants of partial anomalous pulmonary venous return have been reported. We present a rare type of partial anomalous pulmonary venous return in which the anomalous left upper lobe pulmonary vein drained into the left innominate vein via the vertical vein, accompanying the left upper lobe pulmonary vein in the normal location

  7. Anomlus pulmonary venous return aaccompanied by normal superior pulmonary veins in the left upper lobe: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Eon; Kang, Min Jin; Lee, Ji Hae; Bae, Kyung Eun; Kim, Jae Hyung; Kang, Tae Kyung; Kim, Soung Hee; Kim, Ji Young; Jeong, Myeong Ja; Kim, Soo Hyun [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2017-08-15

    Partial anomalous pulmonary venous return is a rare congenital pulmonary venous anomaly, in which some of the pulmonary veins drain into the systemic circulation rather than the left atrium. Many variants of partial anomalous pulmonary venous return have been reported. We present a rare type of partial anomalous pulmonary venous return in which the anomalous left upper lobe pulmonary vein drained into the left innominate vein via the vertical vein, accompanying the left upper lobe pulmonary vein in the normal location.

  8. Estimated venous return surface and cardiac output curve precisely predicts new hemodynamics after volume change.

    Science.gov (United States)

    Sugimachi, Masaru; Sunagawa, Kenji; Uemura, Kazunori; Kamiya, Atsunori; Shimizu, Shuji; Inagaki, Masashi; Shishido, Toshiaki

    2010-01-01

    In our extended Guyton's model, the ability of heart to pump blood is characterized by a cardiac output curve and the ability of vasculature to pool blood by a venous return surface. These intersect in a three-dimensional coordinate system at the operating right atrial pressure, left atrial pressure, and cardiac output. The baseline cardiac output curve and venous return surface and their changes after volume change would predict new hemodynamics. The invasive methods needed to precisely characterize cardiac output curve and venous return surface led us to aim at estimating cardiac output curve and venous return surface from a single hemodynamic measurement. Using the average values for two logarithmic function parameters, and for two slopes of a surface, we were able to estimate cardiac output curve and venous return surface. The estimated curve and surface predicted new hemodynamics after volume change precisely.

  9. Partial anomalous pulmonary venous return in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Sung, Won-kyung; Au, Virginia; Rose, Anand

    2012-01-01

    Anomalous pulmonary venous return is an uncommon congenital malformation, and may be partial or total. Partial anomalous pulmonary venous return (PAPVR) is more common than total anomalous pulmonary venous return, and is often associated with other congenital cardiac anomalies. Whilst many patients with PAPVR remain asymptomatic, some may present in later age with symptoms related to left-to-right shunt, right heart failure and pulmonary hypertension. We report two cases of PAPVR detected on Computed Tomography Pulmonary Angiogram (CTPA) for the work up of pulmonary hypertension. The cases demonstrate that, although uncommon, partial anomalous pulmonary venous return can be a contributing factor to pulmonary hypertension and pulmonary veins should be carefully examined when reading a CTPA study.

  10. The dynamics of venous return and response to hypervolemia in the toad, Bufo marinus (L.)

    OpenAIRE

    Toews Daniel P; Killorn Erin E

    2001-01-01

    Abstract Background Venous return from the posterior region of amphibians travels by either two renal portal veins to the kidney or a central abdominal vein that drains into the hepatic portal system. The relative proportions of blood flow in these vessels has never been measured nor has a modification of flow been determined when venous return increases by changes in blood volume during hypervolemia or during increased volume input from the posterior lymph hearts. Results Venous return from ...

  11. Partial anomalous pulmonary venous return in Turner syndrome.

    Science.gov (United States)

    van den Hoven, Allard T; Chelu, Raluca G; Duijnhouwer, Anthonie L; Demulier, Laurent; Devos, Daniel; Nieman, Koen; Witsenburg, Maarten; van den Bosch, Annemien E; Loeys, Bart L; van Hagen, Iris M; Roos-Hesselink, Jolien W

    2017-10-01

    The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. All Turner patients who presented at our Turner clinic, between January 2007 and October 2015 were included in this study and underwent ECG, echocardiography and advanced imaging such as cardiac magnetic resonance or computed tomography as part of their regular clinical workup. All imaging was re-evaluated and detailed anatomy was described. Partial anomalous pulmonary venous return was diagnosed in 24 (25%) out of 96 Turner patients included and 14 (58%) of these 24 partial anomalous pulmonary venous return had not been reported previously. Right atrial or ventricular dilatation was present in 11 (46%) of 24 partial anomalous pulmonary venous return patients. When studied with advanced imaging modalities and looked for with specific attention, PAPVR is found in 1 out of 4 Turner patients. Half of these patients had right atrial and/or ventricular dilatation. Evaluation of pulmonary venous return should be included in the standard protocol in all Turner patients. Copyright © 2017. Published by Elsevier B.V.

  12. Partial anomalous pulmonary venous return in Turner syndrome

    NARCIS (Netherlands)

    Hoven, A.T. van den; Chelu, R.G.; Duijnhouwer, A.L.; Demulier, L.; Devos, D.; Nieman, K.; Witsenburg, M.; Bosch, A.E. van den; Loeys, B.L.; Hagen, I.M. van; Roos-Hesselink, J.W.

    2017-01-01

    PURPOSE: The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. METHODS AND RESULTS: All Turner patients who presented at our Turner clinic, between January 2007 and October 2015

  13. Partial abnormal pulmonary venous return in Turner syndrome

    NARCIS (Netherlands)

    van Wassenaer, A. G.; Lubbers, L. J.; Losekoot, G.

    1988-01-01

    Three cases of partial anomalous pulmonary venous return, in one case combined with coarctation of the aorta and in another with discrete subaortic stenosis, are described in patients with Turner syndrome. In two of them the right and left superior pulmonary veins drained into the right superior

  14. Models of the venous system

    DEFF Research Database (Denmark)

    Mehlsen, J

    2000-01-01

    of the venous system require at least three elements: a resistor, a capacitor and an inductor, with the latter being of more importance in the venous than in the arterial system. Non-linearities must be considered in pressure/flow relations in the small venules, during venous collapse, or low flow conditions...

  15. A classic learning opportunity from Arthur Guyton and colleagues (1955): circuit analysis of venous return.

    Science.gov (United States)

    Curran-Everett, Douglas

    2007-06-01

    The circuit analysis of an electric analog of the systemic circulation, the focus of a classic paper by Guyton, Lindsey, and Kaufmann, provides a framework for understanding the factors that impact venous return and for appreciating the value of modeling physiological systems. The classic 1955 paper by Guyton, Lindsey, and Kaufmann gives your students an opportunity to learn about modeling from the physiologist who pioneered it (Guyton) and demonstrates that mathematics and data graphics are fundamental tools with which to learn about the regulation of the cardiovascular system. In this essay, I outline avenues of discovery by which your students can explore the factors that impact venous return.

  16. [Anomalous pulmonary venous return in a pregnant woman identified by cardiac magnetic resonance].

    Science.gov (United States)

    Souto, Fernanda Maria; Andrade, Stephanie Macedo; Barreto, Ana Terra Fonseca; Souto, Maria Júlia Silveira; Russo, Maria Amélia; de Mendonça, José Teles; Oliveira, Joselina Luzia Menezes; Gonçalves, Luiz Flávio Galvão

    2014-06-01

    Anomalous pulmonary venous return (APVR) is a rare cardiac anomaly defined as one or more pulmonary veins draining into a structure other than the left atrium, with venous return directly or indirectly to the right atrium. The most common form is partial APVR, in which one to three pulmonary veins drain into systemic veins or into the right atrium. We report the case of a woman diagnosed with partial APVR by magnetic resonance imaging during pregnancy. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  17. The dynamics of venous return and response to hypervolemia in the toad, Bufo marinus (L.).

    Science.gov (United States)

    Killorn, E E; Toews, D P

    2001-01-01

    Venous return from the posterior region of amphibians travels by either two renal portal veins to the kidney or a central abdominal vein that drains into the hepatic portal system. The relative proportions of blood flow in these vessels has never been measured nor has a modification of flow been determined when venous return increases by changes in blood volume during hypervolemia or during increased volume input from the posterior lymph hearts. Venous return from the posterior region of Bufo marinus was measured under resting conditions and in response to a systemic hypervolemia. Doppler flow probes were positioned on the renal portal and ventral abdominal veins, and flow was recorded as injections of artificial plasma equaling 100% of the animal's plasma volume were administered through the sciatic artery. Resting flow was found to be 5.54 +/- 2.03 ml min(-1) kg(-1) in the paired renal portal veins, and 7.31 +/- 0.89 ml min(-1) kg(-1) in the ventral abdominal vein. While renal portal flow was found to increase by a factor of 2.4 times during the first 10 min of hypervolemia, ventral abdominal flow only increased by a factor of 1.3. Our results quantify the contribution to circulation from posterior venous return in the toad Bufo marinus. A preferential movement of excess fluid through the renal portal pathway was also demonstrated, supporting the possibility of water elimination via the renal portal circulation, especially during periods of high water influx into the animals.

  18. The dynamics of venous return and response to hypervolemia in the toad, Bufo marinus (L.

    Directory of Open Access Journals (Sweden)

    Toews Daniel P

    2001-10-01

    Full Text Available Abstract Background Venous return from the posterior region of amphibians travels by either two renal portal veins to the kidney or a central abdominal vein that drains into the hepatic portal system. The relative proportions of blood flow in these vessels has never been measured nor has a modification of flow been determined when venous return increases by changes in blood volume during hypervolemia or during increased volume input from the posterior lymph hearts. Results Venous return from the posterior region of Bufo marinus was measured under resting conditions and in response to a systemic hypervolemia. Doppler flow probes were positioned on the renal portal and ventral abdominal veins, and flow was recorded as injections of artificial plasma equaling 100% of the animal's plasma volume were administered through the sciatic artery. Resting flow was found to be 5.54 ± 2.03 ml min-1 kg-1 in the paired renal portal veins, and 7.31 ± 0.89 ml min-1 kg-1 in the ventral abdominal vein. While renal portal flow was found to increase by a factor of 2.4 times during the first 10 min of hypervolemia, ventral abdominal flow only increased by a factor of 1.3. Conclusions Our results quantify the contribution to circulation from posterior venous return in the toad Bufo marinus. A preferential movement of excess fluid through the renal portal pathway was also demonstrated, supporting the possibility of water elimination via the renal portal circulation, especially during periods of high water influx into the animals.

  19. Transcatheter therapy in partially abnormal pulmonary venous return with additional drainage to the left atrium.

    Science.gov (United States)

    Luciano, Debora; Laux, Daniela; Boudjemline, Younes; Hascoët, Sébastien; Lusson, Jean-René; Sorensen, Clio; Ovaert, Caroline; Kreitmann, Bernard; Van Praagh, Richard; Fraisse, Alain

    2013-12-10

    A persistent anastomosis between the pulmonary veins that connect with the left atrium and the systemic vein that drains into the right atrium has occasionally been reported. We report characteristics and transcatheter therapy in partially abnormal pulmonary venous return with additional drainage to the left atrium. We retrospectively studied such patients in 5 institutions. Ten patients (6 girls) presented at a median age of 8 (0.1 to 54) years with 2 anatomic types: 8 vertical vein types with drainage of the left upper lobe to the innominate vein via a large vertical vein (left superior cardinal vein) and to the left atrium via the left upper pulmonary vein; and 2 scimitar vein (SV) types with drainage of the right middle and lower pulmonary veins into the inferior vena cava and to the left atrium via an anomalous connecting vein. Associated malformations were aortic coarctation (n=2) and secundum atrial septal defects (n=3). Two patients of the vertical vein type were operated. Transcatheter occlusion of the abnormal pulmonary venous return was performed in 7 cases, associated with occlusion of systemic arterial supply (n=2), secundum atrial septal closure (n=2), left upper pulmonary vein stenosis stenting (n=1), and coarctation stenting (n=1). Including previously published cases, 18 patients (13 vertical veins and 5 scimitar veins) underwent transcatheter repair. Patients over 40 years of age tend to be symptomatic at presentation (p=0.056). In partially abnormal pulmonary venous return with dual drainage, transcatheter therapy can be offered in the majority of patients. © 2013.

  20. Systemic Risk and Returns

    OpenAIRE

    Boman, Arthur Lee

    2013-01-01

    I solve a consumption based model, with interfirm systemic risk, for a portfolio optimization with arbitrary return distributions and endogenous stochastic discount factor (sdf). The model highlights a new systemic risk: systemic allocation risk. In contrast to the case without systemic risk, the market and planner allocate capital differently. The externality causes the planner to reduce investment in the risky firm. The market, modeled as a representative agent, does not just ignore the ext...

  1. [Subtotal cor triatriatum sinister associated with bilateral partial anomalous pulmonary venous return].

    Science.gov (United States)

    Işık, Onur; Akyüz, Muhammet; Ayık, Mehmet Fatih; Atay, Yüksel

    2016-03-01

    Cor triatriatum sinister is a rare congenital cardiac pathology, representing only 0.1% of congenital cardiac anomalies, and often associated with other cardiac defects. In classic cor triatriatum sinister, the pulmonary venous chamber receives all pulmonary veins and drains into the left atrium through a variable-sized orifice. The case of a 4-month-old male patient who had subtotal cor triatriatum sinister associated with right and left upper anomalous pulmonary venous return is presented.

  2. A computational model-based validation of Guyton's analysis of cardiac output and venous return curves

    Science.gov (United States)

    Mukkamala, R.; Cohen, R. J.; Mark, R. G.

    2002-01-01

    Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.

  3. Comparison of Venous Return Characteristics with Right Ventricular Mechanics During Cephalic Fluid Shift

    Science.gov (United States)

    Elliott, Morgan; Martin, David

    2015-01-01

    For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail

  4. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  5. Stroke Volume During Concomitant Apnea and Exercise: Influence of Gravity and Venous Return

    Science.gov (United States)

    Hoffmann, Uwe; Drager, Tobias; Steegmanns, Ansgar; Koesterer, Thomas; Linnarsson, Dag

    2008-06-01

    The responses of the cardiovascular system to intensive exercise (hiP) and combined stimuli by hiP and breath-hold (hiP-BH) for 20 s were examined during changing gravity (parabolic flight) and constant gravity (1g). The basic response to microgravity (μg) during low-intensity exercise was an increase in cardiac output (CO) and stroke volume (SV) as a result of augmented venous return. When onset of hiP was superimposed, the initial augmentation of CO and SV were increased further. In contrast, when BH was added, the increases of CO and SV were slowed. We propose that this was due to a transient increase of the pulmonary blood volume with the combination of μg and BH at large lung volume, creating a temporary imbalance between right ventricular input and left ventricular output. In addition, the BH- induced relative bradycardia may have contributed to a prolongation of the right-to- left indirect ventricular interdependence.

  6. Primary correction of total anomalous pulmonary venous return with a modified sutureless technique.

    Science.gov (United States)

    Mueller, Christoph; Dave, Hitendu; Prêtre, René

    2013-03-01

    The objective was to evaluate primary sutureless repair of total anomalous pulmonary venous return (TAPVR) in neonates using a modified technique that minimizes hypothermia and circulatory arrest times. From 2009 to 2011, seven consecutive patients underwent primary sutureless repair for the treatment of TAPVR, by which the prepared posterior pericardium was sutured to an opening in the left atrium. Three patients had the obstructed infracardiac type, and four patients had the unobstructed supracardiac type of TAPVR. Moderate hypothermia was used in all patients with a median temperature of 28°C (26-32). Circulatory arrest was not used except for the opening of the collector, which lasted between 3 and 5 min. The connecting vein was ligated in all seven patients (five during repair and two early postoperatively). The follow-up was 100% complete, with a median duration of 652 (range 370-1023) days. There was no operative mortality and no late death. No patient required reoperation. Postoperative echocardiography showed unobstructed pulmonary venous flow in all patients. Recurrent pulmonary venous stenosis was not seen during the follow-up in any patient. The sutureless technique is an effective technique with potential advantages even for the primary correction of TAPVR. With the described technique, the need for circulatory arrest is substantially reduced. Not handling the pulmonary venous collector by avoiding a direct anastomosis may contribute to better compliance, better growth and the absence of subsequent stenosis.

  7. Pulmonary Hypertension Secondary to Partial Anomalous Pulmonary Venous Return in an Elderly

    Directory of Open Access Journals (Sweden)

    Stefan Koester

    2016-01-01

    Full Text Available Background. Partial anomalous pulmonary venous return (PAPVR is an uncommon congenital abnormality, which may present in the adult population. It is often associated with sinus venosus defect (SVD. The diagnosis and therapy for this condition may be challenging. Case Presentation. We describe a case of an elderly woman who presented with NYHA Class IV dyspnea and was suspected to have symptomatic pulmonary hypertension. She was later found to have anomalous right upper pulmonary vein return to the superior vena cava and associated SVD with bidirectional shunting. Therapeutic options were discussed and medical management alone with aggressive diuresis and sildenafil was adopted. Follow-up visits revealed success in the planned medical therapy. Conclusions. PAPVR is a rare congenital condition that may present during late adulthood. The initial predominant left-to-right shunting associated with this anomaly may go undetected for years with the gradual development of pulmonary hypertension and right heart failure due to right heart volume overload. Awareness of the condition is important, as therapy is time-sensitive with early detection potentially leading to surgical therapy as a viable option.

  8. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  9. Congenital absence of infrarenal IVC and iliac venous system : Unusual collateral Pathways

    International Nuclear Information System (INIS)

    Lee, Jin Joo; Lee, Byung Hee; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil

    1994-01-01

    We present a case with congenital absence of the infrarenal portion of inferior vena cava and iliac venous system, showing unusual venous collaterals including the left ovarian venous collateral via parametrial venous complex, and a mesenteric-periureteric venous connection. The venous collateral pathways were demonstrated by computed tomography and venography

  10. Anomalía del retorno venoso sistémico Drenaje anómalo de la vena cava superior derecha a la aurícula izquierda: Revisión de la literatura y reporte de caso Anomalous systemic venous return. Anomalous drainage of the right superior vena cava into the left atrium: Review of literature and case report

    Directory of Open Access Journals (Sweden)

    Ríos Giovanny

    2012-06-01

    Full Text Available La anomalía total del retorno venoso sistémico tiene gran variedad de presentaciones; sin embargo, la patología de más baja frecuencia es el drenaje de vena cava superior derecha a la aurícula izquierda, hecho de peso para que en el mundo se reporten pocos casos. En la Fundación Clínica Abood Shaio se trató el caso de una paciente de seis años de edad con drenaje venoso total de cava superior derecha a la aurícula izquierda, mediante la técnica de movilización de cava superior y anastomosis cavo-atrial, y se obtuvieron buenos resultados. El caso es mención corresponde al número 21 en la literatura mundial.Total anomalous systemic venous return has a variety of presentations, being the drainage of right superior vena cava into the left atrium a low frequency condition. There are few reported cases in the world. In Shaio Clinic Foundation we have handled a case of total venous drainage of the right superior vena cava into the left atrium in a 6-year old girl, using the superior vena cava mobilization technique and cavo-atrial anastomosis, with good results. This case is reported as case number 21 in the world.

  11. Anatomic resection to manage donor partial anomalous pulmonary venous return during lung transplantation: a case report and review.

    Science.gov (United States)

    Melvan, J N; Force, S D; Sancheti, M S

    2015-04-01

    Rare vascular malformations are discovered infrequently in donor lungs before implantation into recipients. However, the proper handling of such malformations can influence ischemic time, implantation strategies, and subsequent patient outcomes. We report a simplified method for addressing the technical challenges of anomalous pulmonary venous return in a donor lung before implantation. We demonstrate that anatomic resection is a safe and efficient method for managing this rare congenital vascular malformation. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. THE AZYGOS VENOUS SYSTEM AND ITS ANATOMICAL VARIATIONS

    Directory of Open Access Journals (Sweden)

    Madiki Sudhakara Rao

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES Azygos veins are important cavocaval and portacaval junctions, which form a collateral circulation in caval vein occlusion and in portal hypertension, cirrhosis of liver. The unpaired azygos venous system consists of azygos vein, hemiazygos vein and accessory azygos vein. This system of veins, along with its mediastinal, bronchial and oesophageal tributaries drains most of the body wall of trunk, namely posterior abdominal and thoracic wall. Anatomical variations of this unpaired azygos venous system are clinically important. AIMS To study and report the occurrence of anatomical variations of the unpaired azygos venous system in the region of East Godavari District, Andhra Pradesh (India. METHODS The present study was carried out in the Department of Anatomy, KIMS & RF, Amalapuram and G.S.L. Medical College, Rajahmundry over a period of 2 years. The present study was conducted on 60 cadavers (irrespective of age and sex. The entire course of the azygos venous system in these 60 cadavers was carefully observed and documented. RESULTS Anatomical variations were present in 16.66% of cases, out of which three distinct types were identified. 6.6% exhibited two separate azygos venous systems with no communications, 5% with communication between the left brachiocephalic vein and the azygos vein and 5% presence of post-aortic venous channels. CONCLUSION Variations of azygos venous system may be wrongly dubbed as aneurysm, lymphadenopathy or other abnormalities while reporting a CT scan of mediastinum. Venous anomalies are also detected only during surgery. The most troublesome intraoperative hazard is haemorrhage, which is mainly of venous origin. To avoid such situations is to have an awareness and knowledge of the expected venous anomalies.

  13. Effect of Multi-layer Compression Bandage Systems on Leg Ulcers Associated with Chronic Venous Insufficiency

    Directory of Open Access Journals (Sweden)

    Hüseyin Kuplay

    2013-03-01

    Full Text Available Introduction: Venous leg ulcer is a major health problem in terms of high prevalence and high cost for treatment. Multi-layer compression bandage systems for venous leg ulcers are supposed to be the gold standard for the treatment of venous ulcers. The aim of the current study is to investigate the effectiveness of multi-layer compression bandage systems for the treatment of venous leg ulcers.Patients and Methods: Nineteen consecutive patients diagnosed to have leg ulcers were evaluated and four patients were excluded from the study due to the peripheral arterial disease. Fifteen patients, enrolled in the study, were classified according to CEAP classification and belonged to the same class. Betaven® multi-layer compression bandage was applied to patients. Patients were followed-up in terms of wound healing and reduction in wound diameter.Results: Twelve male and three female patients underwent multi-layer bandage system. Mean age of patients was 38.2 ± 4.2 years. Ulcer size was measured planimetrically and baseline ulcer size was 4-10 cm². The location of ulcer was on medial malloelus in seven patients, lateral malleolus in three patients, anterior surface of the leg in four patients and lateral side of the leg in one patient. Patients had chronic venous insuuficiency for a mean of 5.1 ± 2.1 years. CEAP classifications were C6, Ep, As2,3-p18, Pr2,3, 18. Each bandage was changed five days after application along with wound care. Mean duration of treatment was 6 ± 2 weeks. Complete healing of the venous ulcers occurred in all patients except for one. This patient was referred to plastic surgery clinic for reconstruction.Conclusion: Multi-layer compression bandage system is an effective method of treatment for venous leg ulcers associated with chronic venous insufficiency by reducing venous return and increasing intertitial tissue pressure. This effect occurred in the shortrun as well as with a low cost and prevented loss of labor.

  14. Aneurysms of the superficial venous system: classification and treatment

    Directory of Open Access Journals (Sweden)

    Ronald G. Bush

    2014-11-01

    Full Text Available Superficial venous aneurysms are rarely described and they may remain indolent or become the source for pulmonary emboli. A system of classification and treatment protocol according to size and location is proposed. Three hundred thirty patients were evaluated for symptomatic venous disease (C2-C6 over a 2-year period. A proposed designation for venous aneurysm is described. Patients fulfilling this criterion are described in reference to site of involvement, histologic findings, and method of treatment. Five percent of patients met the criteria for venous aneurysm. Nine aneurysms of the greater saphenous vein were identified. Three aneurysms were proximal to the subterminal valve and the rest were distal. Six aneurysms of the anterior accessory greater saphenous vein (AAGSV were identified. Three aneurysms of the AAGSV spontaneously thrombosed. Two patients presented with aneurysms of the small saphenous vein. Histology revealed thickened intima, smooth muscle and adventitia. Aneurysm designation relates to diameter of normal and contiguous vein. All superficial venous aneurysms in close proximity to the junction of the femoral or popliteal vein should be ligated. Classification of venous aneurysms should include the AAGSV, which may present with spontaneous thrombosis.

  15. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  16. Total Anomalous Pulmonary Venous Connection: Preoperative Anatomy, Physiology, Imaging, and Interventional Management of Postoperative Pulmonary Venous Obstruction.

    Science.gov (United States)

    Files, Matthew D; Morray, Brian

    2017-06-01

    Total anomalous pulmonary venous connection refers to a spectrum of cardiac anomalies where the pulmonary veins fail to return to the left atrium and the pulmonary venous blood returns through a systemic vein or directly to the right atrium. There is a wide anatomical variety of venous connections and degrees of pulmonary venous obstruction that affect the presentation, surgical repair, and outcomes. In this review, we explore the preoperative physiology, echocardiographic diagnosis, and approach to postoperative complications.

  17. 'Chronic cerebrospinal venous insufficiency' in multiple sclerosis. Is multiple sclerosis a disease of the cerebrospinal venous outflow system?

    International Nuclear Information System (INIS)

    Wattjes, M.P.; Doepp, F.; Bendszus, M.; Fiehler, J.

    2011-01-01

    Chronic impaired venous outflow from the central nervous system has recently been claimed to be associated with multiple sclerosis (MS) pathology. This resulted in the term chronic cerebrospinal venous insufficiency (CCSVI) in MS. The concept of CCSVI is based on sonography studies showing that impaired venous outflow leading to pathological reflux is almost exclusively present in MS patients but not in healthy controls. Based on these findings, a new pathophysiological concept has been introduced suggesting that chronic venous outflow obstruction and venous reflux in the CNS result in pathological iron depositions leading to inflammation and neurodegeneration. The theory of CCSVI in MS has rapidly generated tremendous interest in the media and among patients and the scientific community. In particular, the potential shift in treatment concepts possibly leading to an interventional treatment approach including balloon angioplasty and venous stent placement is currently being debated. However, results from recent studies involving several imaging modalities have raised substantial concerns regarding the CCSVI concept in MS. In this review article, we explain the concept of CCSVI in MS and discuss this hypothesis in the context of MS pathophysiology and imaging studies which have tried to reproduce or refute this theory. In addition, we draw some major conclusions focusing in particular on the crucial question as to whether interventional treatment options are expedient. In conclusion, the present conclusive data confuting the theory of CCSVI in MS should lead to reluctance with respect to the interventional treatment of possible venous anomalies in MS patients. (orig.)

  18. ANALYSING TURKISH INDIVIDUAL PENSION SYSTEM FEES AND RETURNS

    OpenAIRE

    Peker, Ibrahim

    2018-01-01

    This study aims at categorizing, computing and analyzing fees and costs in Turkish Individual Pension System. To this end, net real returns after all costs were computed and these returns were compared with the disclosed fees and returns. Generally in practice, only fund management fees are taken into consideration for calculating net returns and with this method net annual average (geometric) return of the system is calculated as 2.01% for the 2008-2014 period. However, the results of this s...

  19. Anatomical evaluation of penile venous system by CT cavernosography in patients with erectile dysfunction and venous leakage

    Directory of Open Access Journals (Sweden)

    Ghafoori M

    2012-11-01

    Full Text Available Background: Erectile dysfunction is an important problem in men and an organic cause is found in about 50% of cases. When a vasculogenic etiology is suspected, imaging assessments are of great help. Cavernosography is traditionally recognized as an imaging modality for evaluation of venous leakage in men with impotency. We employed CT cavernosography as a novel technique for demonstrating penile venous anatomy and leaking veins.Methods: In the present case series study, we recruited 45 patients with erectile dysfunction by convenient sampling at Hazrat Rasoul Akram Hospital in Tehran, Iran, during one year (1390. The patients had previously been diagnosed with venous incompetency by Doppler study. After intracavernosal injection of prostaglandin E1, we injected sterile normal saline into the corpora cavernosa to achieve penile erection. Later, we injected contrast media into the corpus cavernosum, which was followed by CT scan of the penis and pelvic area to show the venous anatomy and leakage sites.Results: The mean age of the patients was 35.8±8.9 years. 36 (80% patients had venous leakage in crural veins, 27 (60% in cavernosal veins, 27 (60% in circumflex veins, 24 (52.3% in urethral veins, 21 (46.7% in deep dorsal vein, 3 (6.7% in para-arterial veins and 3 (6.7% in corpus spongiosum. Conclusion: The results of this study show the high prevalence of venous leakage in patients referring for erectile dysfunction. Moreover, CT cavernosography was shown to be a useful method for evaluating penile venous system and its related leakage sites which are important for surgical planning.

  20. The Anatomical Correlation between the Internal Venous Vertebral System and the Cranial Venae Cavae in Rabbit

    OpenAIRE

    Mazensky, David; Petrovova, Eva; Danko, Jan

    2013-01-01

    The aim of this study was to describe the possible variations in the connection between the internal venous vertebral system and the cranial vena cava in rabbit using corrosion technique. The study was carried out on 40 adult New Zealand white rabbits. The venous system was injected by using Batson's corrosion casting kit number 17. We found the connection between the internal venous vertebral system and the cranial vena cava by means of the vertebral veins and the right azygos vein. The vert...

  1. A Mars Sample Return Sample Handling System

    Science.gov (United States)

    Wilson, David; Stroker, Carol

    2013-01-01

    We present a sample handling system, a subsystem of the proposed Dragon landed Mars Sample Return (MSR) mission [1], that can return to Earth orbit a significant mass of frozen Mars samples potentially consisting of: rock cores, subsurface drilled rock and ice cuttings, pebble sized rocks, and soil scoops. The sample collection, storage, retrieval and packaging assumptions and concepts in this study are applicable for the NASA's MPPG MSR mission architecture options [2]. Our study assumes a predecessor rover mission collects samples for return to Earth to address questions on: past life, climate change, water history, age dating, understanding Mars interior evolution [3], and, human safety and in-situ resource utilization. Hence the rover will have "integrated priorities for rock sampling" [3] that cover collection of subaqueous or hydrothermal sediments, low-temperature fluidaltered rocks, unaltered igneous rocks, regolith and atmosphere samples. Samples could include: drilled rock cores, alluvial and fluvial deposits, subsurface ice and soils, clays, sulfates, salts including perchlorates, aeolian deposits, and concretions. Thus samples will have a broad range of bulk densities, and require for Earth based analysis where practical: in-situ characterization, management of degradation such as perchlorate deliquescence and volatile release, and contamination management. We propose to adopt a sample container with a set of cups each with a sample from a specific location. We considered two sample cups sizes: (1) a small cup sized for samples matching those submitted to in-situ characterization instruments, and, (2) a larger cup for 100 mm rock cores [4] and pebble sized rocks, thus providing diverse samples and optimizing the MSR sample mass payload fraction for a given payload volume. We minimize sample degradation by keeping them frozen in the MSR payload sample canister using Peltier chip cooling. The cups are sealed by interference fitted heat activated memory

  2. Port Placement via the Anterior Jugular Venous System: Case Report, Anatomic Considerations, and Literature Review

    Directory of Open Access Journals (Sweden)

    Gernot Rott

    2017-01-01

    Full Text Available We report on a patient who was referred for port implantation with a two-chamber pacemaker aggregate on the right and total occlusion of the central veins on the left side. Venous access for port implantation was performed via left side puncture of the horizontal segment of the anterior jugular vein system (AJVS and insertion of the port catheter using a crossover technique from the left to the right venous system via the jugular venous arch (JVA. The clinical significance of the AJVS and the JVA for central venous access and port implantation is emphasised and the corresponding literature is reviewed.

  3. Case report: portal and systemic venous gas in a patient with perforated duodenal ulcer: CT findings.

    Science.gov (United States)

    Fam, Maged Nassef Abdalla; Attia, Khaled Mostafa Elgharib; Khalil, Safaa Maged Fathelbab

    2014-07-01

    Gas within the portal circulation has been known to be associated with a number of conditions most commonly mesenteric ischemia and necrosis. Systemic venous gas is described with few conditions and is mostly iatrogenic in nature. We describe a case of combined portal and systemic venous gas detected by computed tomography in a patient with perforated duodenal ulcer.

  4. [Physiotherapy potentials improve the calf muscle pump function in chronic venous insufficiency].

    Science.gov (United States)

    Dymarek, Robert; Ptaszkowski, Kuba; Słupska, Lucyna; Rajfur, Joanna; Pasternok, Małgorzata; Taradaj, Jakub; Halski, Tomasz

    2014-01-01

    Mechanism of the calf muscle pump plays a major role in venous blood return from peripheral parts of blood vessels of lower extremities. It enables a smooth venous blood movement from the deep venous system segment located below in a direction to the segment lying above which effectively prevents a distal blood stasis and veno-lymphatic edema of lower limbs. Calf muscle pump dysfunction together with disorders in the construction of blood vessels walls and with endurance weakness of valves, leads to venous hypertension and contributes to the development of venous insufficiency. The aim of this paper is to demonstrate the theoretical basis including venous return physiology and the mechanism of lower limbs venous--muscle pump as well as provide practical application of physiotherapy methods to support the properfunction of presented calf muscle pump. Examples in the field of physical medicine, compression therapy and kinesiotherapy for improving the efficiency of lower extremity muscles, providing a physiological venous return.

  5. Sample Return Systems for Extreme Environments

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase I we were able to demonstrate that sample return missions utilizing high velocity penetrators (0.1- 1 km/s) could provide substantial new capabilities for...

  6. Sample Return Systems for Extreme Environments

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work seeks to design, develop and test a hard impact penetrator/sampler that can withstand the hard impact and enable the sample to be returned to...

  7. The deep venous system of the lower extremity: new nomenclature.

    Science.gov (United States)

    Kachlik, D; Pechacek, V; Musil, V; Baca, V

    2012-03-01

    The correct and precise nomenclature of the veins of the lower extremity is a necessary tool for communication. Three important changes have been done over the last 13 years. Terminologia Anatomica, the latest version of the Latin anatomical nomenclature, was published in 1998, extended in the area of the lower extremity veins with two consensus documents, in 2001, during the 14th World Congress of the International Union of Phlebology and in 2004 during the 21st World Congress of the International Union of Angiology. This article is a free continuation of two previous articles, reviewing the detailed anatomy and correct nomenclature of the superficial veins of the lower extremities and veins of pelvis. Now, it is concentrated on the deep venous system, in which 15 new terms have been added in both Latin and English languages.

  8. MR angiography and flow quantitation in the portal venous system

    International Nuclear Information System (INIS)

    Edelman, R.R.; Finn, J.P.; Wentz, K.U.; Zhao, B.; Liu, C.; Mattle, H.; Longmaid, H.E.; McArdle, C.

    1989-01-01

    MR angiography was used to image the portal venous system. Projection venograms were produced from a series of two-dimensional flow-compensated gradient-echo images obtained during breath holding. The authors determined flow direction and velocity by means of dynamic bolus tracking. Six healthy subjects and four patients with portal hypertension were studied. This technique was able to demonstrate consistently the main portal vein and intrahepatic branches, the splenic vein, and the superior and inferior mesenteric veins. Peak flow velocities as determined with MR imaging (17.9 cm/sec ± 2.8) correlated closely with those measured with duplex US (17.5 cm/sec ± 2.2) (r = .846, P<.04). Reversal of portal flow, portal vein thrombosis, and portosystemic collaterals were well shown

  9. Presence of air in the hepatic portal system in association with umbilical venous catheter malposition

    Directory of Open Access Journals (Sweden)

    Beatriz Regina Alvares

    2014-01-01

    Full Text Available The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.

  10. Superficial venous disease.

    Science.gov (United States)

    Brown, Kellie R; Rossi, Peter J

    2013-08-01

    Superficial venous disease is a common clinical problem. The concerning disease states of the superficial venous system are venous reflux, varicose veins, and superficial venous thrombosis. Superficial venous reflux can be a significant contributor to chronic venous stasis wounds of the lower extremity, the treatment of which can be costly both in terms of overall health care expenditure and lost working days for affected patients. Although commonly thought of as a benign process, superficial venous thrombosis is associated with several underlying pathologic processes, including malignancy and deep venous thrombosis. Published by Elsevier Inc.

  11. The superficial venous system of the lower extremity: new nomenclature.

    Science.gov (United States)

    Kachlik, D; Pechacek, V; Baca, V; Musil, V

    2010-06-01

    The phlebology in the area of lower limbs is the only medical field in which the terminological needs of clinicians were met. Ten years ago, the latest revision of the Latin anatomical nomenclature, Terminologia Anatomica (TA), was issued. But almost none of the chapters reflected the clinicians' need to be a relevant theoretical base for correct diagnostics and appropriate treatment. In 2001, during the 14th World Congress of the International Union of Phlebology, a consensus document (under the auspices of Federative International Committee on Anatomical Terminology and International Federation of Associations of Anatomists) was laid to expand the nomenclature of the lower extremity venous system. Some terms have been changed and several new have been added, corresponding to their clinical significance and anatomical positions. Sixteen new terms have been added in both Latin and English languages in the chapter concerning the superficial veins of the lower limb. This consensus document will be incorporated into the next version of the TA. The international anatomical nomenclature serves as a communication base for research, diagnostic, therapy and information exchange in phlebological sciences.

  12. The ovine cerebral venous system: comparative anatomy, visualization, and implications for translational research.

    Science.gov (United States)

    Hoffmann, Anke; Stoffel, Michael H; Nitzsche, Björn; Lobsien, Donald; Seeger, Johannes; Schneider, Holm; Boltze, Johannes

    2014-01-01

    Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an 'anterior condylar confluent' as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research.

  13. The Ovine Cerebral Venous System: Comparative Anatomy, Visualization, and Implications for Translational Research

    Science.gov (United States)

    Nitzsche, Björn; Lobsien, Donald; Seeger, Johannes; Schneider, Holm; Boltze, Johannes

    2014-01-01

    Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an ‘anterior condylar confluent’ as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research. PMID:24736654

  14. Risk-return relationship in a complex adaptive system.

    Directory of Open Access Journals (Sweden)

    Kunyu Song

    Full Text Available For survival and development, autonomous agents in complex adaptive systems involving the human society must compete against or collaborate with others for sharing limited resources or wealth, by using different methods. One method is to invest, in order to obtain payoffs with risk. It is a common belief that investments with a positive risk-return relationship (namely, high risk high return and vice versa are dominant over those with a negative risk-return relationship (i.e., high risk low return and vice versa in the human society; the belief has a notable impact on daily investing activities of investors. Here we investigate the risk-return relationship in a model complex adaptive system, in order to study the effect of both market efficiency and closeness that exist in the human society and play an important role in helping to establish traditional finance/economics theories. We conduct a series of computer-aided human experiments, and also perform agent-based simulations and theoretical analysis to confirm the experimental observations and reveal the underlying mechanism. We report that investments with a negative risk-return relationship have dominance over those with a positive risk-return relationship instead in such a complex adaptive systems. We formulate the dynamical process for the system's evolution, which helps to discover the different role of identical and heterogeneous preferences. This work might be valuable not only to complexity science, but also to finance and economics, to management and social science, and to physics.

  15. Risk-return relationship in a complex adaptive system.

    Science.gov (United States)

    Song, Kunyu; An, Kenan; Yang, Guang; Huang, Jiping

    2012-01-01

    For survival and development, autonomous agents in complex adaptive systems involving the human society must compete against or collaborate with others for sharing limited resources or wealth, by using different methods. One method is to invest, in order to obtain payoffs with risk. It is a common belief that investments with a positive risk-return relationship (namely, high risk high return and vice versa) are dominant over those with a negative risk-return relationship (i.e., high risk low return and vice versa) in the human society; the belief has a notable impact on daily investing activities of investors. Here we investigate the risk-return relationship in a model complex adaptive system, in order to study the effect of both market efficiency and closeness that exist in the human society and play an important role in helping to establish traditional finance/economics theories. We conduct a series of computer-aided human experiments, and also perform agent-based simulations and theoretical analysis to confirm the experimental observations and reveal the underlying mechanism. We report that investments with a negative risk-return relationship have dominance over those with a positive risk-return relationship instead in such a complex adaptive systems. We formulate the dynamical process for the system's evolution, which helps to discover the different role of identical and heterogeneous preferences. This work might be valuable not only to complexity science, but also to finance and economics, to management and social science, and to physics.

  16. Vertebral venous system abnormalities identified with magnetic resonance imaging in sighthounds.

    Science.gov (United States)

    Vernon, John C; Durand, Alexane; Guevar, Julien; José-López, Roberto; Hammond, Gawain; Stalin, Catherine; Gutierrez-Quintana, Rodrigo

    2017-07-01

    In humans, abnormalities of the vertebral venous system are considered rare but significant causes of radiculopathy and myelopathy. Published information on abnormalities of the canine vertebral venous system is currently lacking. Aims of this retrospective descriptive study were to characterize magnetic resonance imaging (MRI) abnormalities of the vertebral venous system in a population of sighthounds, report prevalence of vertebral venous system abnormalities within that population and explore possible clinical significance. Our hospital database was searched over the period of 2002-2013 for sighthounds with MRI studies of the vertebral column. Medical records and MRI studies for included dogs were retrieved and findings were recorded by a single observer. A total of 92 sighthounds were sampled. Eleven cases (prevalence 12%) showed abnormal enlargement of the internal vertebral venous plexus (10/11 unilaterally, 1/11 bilaterally), external vertebral venous plexus (7/11 cases unilaterally), and/or intervertebral veins (8/11 unilaterally, 2/11 bilaterally, and 1/11 unilaterally and bilaterally at different sites). The majority of the abnormalities were right sided and the most common location for abnormalities was C6/7. Of the 11 cases, nine did not have a definitive diagnosis. Seven of those nine cases had an abnormality in a neuroanatomical localization that could wholly or partly explain the clinical signs. Findings indicated that, while the prevalence of vertebral venous system abnormalities was low in this sample of sighthounds, the majority of dogs with these abnormalities had clinical signs that matched the location of the abnormalities. Further prospective research is needed to investigate potential underlying aetiologies for vertebral venous system abnormalities in dogs and clarify their clinical significance. © 2017 American College of Veterinary Radiology.

  17. The present status of surgery of the superficial venous system in the management of venous ulcer and the evidence for the role of perforator interruption.

    Science.gov (United States)

    O'Donnell, Thomas F

    2008-10-01

    Superficial venous hypertension has been cited as the putative etiologic factor in advanced chronic venous insufficiency with venous ulcer (CEAP C 5/6). For over a century, influenced by this belief, surgeons have ablated the superficial venous system as a treatment for venous ulcer. Incompetent perforating veins (ICPVs) have become a particular focus of this therapeutic strategy. This review examines the evidence for the surgical approach. A MEDLINE search of the literature identified only four randomized controlled trials (RCTs) directed at the surgical reduction of superficial venous hypertension. Risk ratios for ulcer healing and prevention of recurrence were calculated to determine benefits for these four RCTs, while mortality and morbidity, where available, was used to determine risk from the procedure. In addition, the quality of the trials (design and outcomes) was assessed. While two trials compared ICPV ligation to compression, the great saphenous vein (GSV) was also treated in many of these limbs, which confounds the results. By contrast, two RCTs, which compared treatment of the GSV alone to compression, demonstrated a significant reduction in the incidence of ulcer recurrence. Case series that employed hemodynamic or surrogate outcomes showed little effect on the addition of ICPV treatment to GSV stripping, while GSV ablation alone was associated with a reduction in the number of ICPVs in several studies. This review suggests a grade 1A recommendation for the treatment of venous ulcer by GSV ablation to reduce ulcer recurrence. The role of ICPV ablation alone or concomitant with GSV treatment awaits results of properly conducted RCTs.

  18. Venous Sampling

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Venous sampling Venous sampling is a diagnostic procedure that uses ... the limitations of venous sampling? What is venous sampling? Venous sampling is a diagnostic procedure that involves ...

  19. Anatomy of the mastoid emissary vein and venous system of the posterior neck region: neurosurgical implications.

    Science.gov (United States)

    Reis, Cassius V C; Deshmukh, Vivek; Zabramski, Joseph M; Crusius, Marcelo; Desmukh, Pushpa; Spetzler, Robert F; Preul, Mark C

    2007-11-01

    The superficial venous system of the posterior neck (suboccipital venous plexus) is a potential source of complications from bleeding and air embolism. Because there is little information available about this in the literature, an anatomic study of the superficial posterior neck venous system and a morphometric analysis of the mastoid emissary vein (MEV) complex were undertaken. Both surgical and endovascular implications were considered. The posterior craniocervical regions of 15 silicon-injected human cadaveric specimens were dissected. The patterns and variances of venous anatomy were observed. Distances between fixed bony landmarks were measured with a caliper. The suboccipital venous plexus, which forms a complex venous network located between the posterior muscular layers of the neck, drains to the anterior vertebral vein and deep cervical vein. The MEV connects this plexus to the sigmoid sinus. Its average diameter was 2.15 mm, and it was located a mean of 21.14 mm from the asterion and a mean of 33.65 mm from the mastoid tip. However, the size of the MEV complex varied considerably. The suboccipital venous plexus in the posterior neck region may be very large. The size of the veins in the plexus varies, but the drainage pattern remains consistent. The plexus is a potential source of intense bleeding and air embolism during posterior fossa approaches. The risks are greatest for lateral surgical approaches, as a result of the anatomic position of the venous system. The described measurements can be used to approach the MEV in endovascular procedures that involve the sigmoid sinus.

  20. Abnormal systemic venous connection possibly associated with a persistent right umbilical vein; a case report

    Directory of Open Access Journals (Sweden)

    Smevik Bjarne

    2004-04-01

    Full Text Available Abstract Background Abnormal venous connections involving a persistent right umbilical vein are rare. In a minority of cases the liver is entirely bypassed and the condition is associated with multiple congenital malformations. Case presentation The described case illustrates a systemic venous drainage that was severely abnormal in a newborn girl with a truncus arteriosus type II congenital heart defect. Injection of contrast medium through the umbilical vein catheter revealed a very peculiar venous connection that passed anterio-laterally through the right hemithorax before crossing in an oblique fashion towards the superior vena cava. Conclusions This venous drainage may be the result of a persistent right umbilical vein connecting with the superior vena cava.

  1. A Comet Surface Sample Return System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase I investigation will focus on the development of spacecraft systems required to obtain a sample from the nucleus of a comet, hermetically seal the...

  2. The collateral venous system in late pregnancy: A systematic review of the literature.

    Science.gov (United States)

    Humphries, Aimee; Stone, Peter; Mirjalili, S Ali

    2017-11-01

    Recent literature has reported an association between maternal supine sleep position and stillbirth during late pregnancy. In this position the gravid uterus almost completely obstructs the inferior vena cava. A small number of women experience supine hypotension, thought to be due in part to inadequate collateral venous circulation. The aim of this paper is to review the literature describing the anatomy of the collateral venous system and in particular the azygos system, the abdominal portion of which has not been well studied. A systematic review was conducted using the electronic databases: Medline, Embase, Scopus, and Google Scholar. Relevant anatomical and radiological literature concerning the azygos system in particular was reviewed. The search was limited to adult human studies only. The collateral venous system can be divided into superficial, intermediate and deep systems. The azygos system in particular provides immediate collateral venous circulation in the event of acute inferior vena caval obstruction. The abdominal portion of this pathway, including the ascending lumbar vein, has not been well studied and there are certain variations that can render it ineffective. In conclusion, the collateral venous system provides an alternative route for blood to flow back to the systemic circulation when acute occlusion of the inferior vena cava occurs in the supine position during late pregnancy. However, certain anatomical variations can render this pathway ineffective, and this could have implications for the development of supine hypotension and stillbirth in late pregnancy. Clin. Anat. 30:1087-1095, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. [Expert system to support the decision in topical therapy for venous ulcers].

    Science.gov (United States)

    Sellmer, Danielle; Carvalho, Carina Maris Gaspar; Carvalho, Deborah Ribeiro; Malucelli, Andreia

    2013-06-01

    Although the treatment of venous ulcers requires a set of specific knowledge, non-specialist nurses are unaware of the appropriate therapy, which is a concern in the topical therapy for these skin lesions. This paper aims to present an expert system to support the nursing decision making process in the topical therapy of venous ulcers. It is a development research implemented in five stages: system modeling, knowledge acquisition, knowledge representation from production rules, and system implementation and evaluation. The production rules are presented as well as some cases to simulate the expert system behavior, demonstrating the viability of its usage in nurse's practice. The system may support the decision making about the topical therapy of venous ulcers. However, ulcer evaluation should be correctly made, so that the system provides appropriate suggestions, allowing better organization and planning assistance.

  4. The study of human venous system dynamics using hybrid computer modeling

    Science.gov (United States)

    Snyder, M. F.; Rideout, V. C.

    1972-01-01

    A computer-based model of the cardiovascular system was created emphasizing effects on the systemic venous system. Certain physiological aspects were emphasized: effects of heart rate, tilting, changes in respiration, and leg muscular contractions. The results from the model showed close correlation with findings previously reported in the literature.

  5. Use of ultraportable vacuum therapy systems in the treatment of venous leg ulcer.

    Science.gov (United States)

    Cuomo, Roberto; Nisi, Giuseppe; Grimaldi, Luca; Brandi, Cesare; D'Aniello, Carlo

    2017-10-23

    The high incidence of venous leg ulcers and the difficult to give a complete healing involves in an increase of costs for National Health System. Main therapies to obtain a fast healing are compressive bandages, treatment of abnormal venous flow and in-situ-strategies of wound care. Negative pressure therapy does not conventionally used, because these systems not allow the use of compression bandages. Recently the development of ultraportable devices has improved the compliance and the results. Ten patients with venous chronic ulcer on the lower extremities were recruited for this study: all patients had venous leg ulcers from at least one year. We treated the patients with autologous partial thickness skin graft and subsequently we applied NANOVA device included in compressive bandage. We used NANOVA for fourteen days and after we made traditional medications. We submitted a questionnaire to evaluate the impact of dressing and NANOVA device in the quality of life of patients. The device contributed to the formation of granulation tissue and increased the success rate of autologous skin graft without limiting mobility of patient. In addition to this, we have been able to perform compression bandages thanks to small size of this device. Eight ulcers healed within 90 days of medication. We believe that ultraportable negative pressure systems are useful devices for treatment of venous leg ulcers because them allows to realize a compressive bandage without mobility limitations.

  6. Contribution of systemic venous hypertension to the development of pulmonary edema in dogs.

    Science.gov (United States)

    Miller, W C; Simi, W W; Rice, D L

    1978-10-01

    Systemic venous hypertension (SVH) is a frequent finding in pulmonary edema. To study the possible contributory or even causal role of SVH in pulmonary edema, a dog model was developed in which balloon catheters were placed in the left and right atria. Inflation of the left atrial balloon produced a tendency to pulmonary edema by causing pulmonary venous hypertension (PVH) (pulmonary artery wedge pressure of 20 mmHg). Inflation of the right atrial balloon produced SVH (central venous pressure of 15 mm Hg). After 2 hours, dogs with SVH with or without PVH demonstrated a greater amount of lung fluid accumulation (P less than 0.01) compared to controls or PVH alone. There was no significant difference in lung water in SVH dogs with or without PVH. Pulmonary blood flow was not significantly different between the experimental groups, each of which was less than control. Impairment of pulmonary lymphatic flow is one possible mechanism producing the worsening edema; however, bronchial venous hypertension or neurogenic reflexes cannot be excluded. We conclude that the contribution of systemic venous hypertension to the development of pulmonary edema may have therapeutic implications.

  7. Anesthetic implications of total anomalous systemic venous connection to left atrium with left isomerism

    Directory of Open Access Journals (Sweden)

    Parimala Prasanna Simha

    2012-01-01

    Full Text Available Total anomalous systemic venous connection (TASVC to the left atrium (LA is a rare congenital anomaly. An 11-year-old girl presented with complaints of palpitations and cyanosis. TASVC with left isomerism and noncompaction of LV was diagnosed after contrast echocardiogram and computed tomography angiogram. The knowledge of anatomy and pathophysiology is essential for the successful management of these cases. Anesthetic concerns in this case were polycythemia, paradoxical embolism and rhythm abnormalities. The patient was successfully operated by rerouting the systemic venous connection to the right atrium.

  8. Shared Segment Analysis and Next-Generation Sequencing Implicates the Retinoic Acid Signaling Pathway in Total Anomalous Pulmonary Venous Return (TAPVR.

    Directory of Open Access Journals (Sweden)

    Dustin Nash

    Full Text Available Most isolated congenital heart defects are thought to be sporadic and are often ascribed to multifactorial mechanisms with poorly understood genetics. Total Anomalous Pulmonary Venous Return (TAPVR occurs in 1 in 15,000 live-born infants and occurs either in isolation or as part of a syndrome involving aberrant left-right development. Previously, we reported causative links between TAVPR and the PDGFRA gene. TAPVR has also been linked to the ANKRD1/CARP genes. However, these genes only explain a small fraction of the heritability of the condition. By examination of phased single nucleotide polymorphism genotype data from 5 distantly related TAPVR patients we identified a single 25 cM shared, Identical by Descent genomic segment on the short arm of chromosome 12 shared by 3 of the patients and their obligate-carrier parents. Whole genome sequence (WGS analysis identified a non-synonymous variant within the shared segment in the retinol binding protein 5 (RBP5 gene. The RBP5 variant is predicted to be deleterious and is overrepresented in the TAPVR population. Gene expression and functional analysis of the zebrafish orthologue, rbp7, supports the notion that RBP5 is a TAPVR susceptibility gene. Additional sequence analysis also uncovered deleterious variants in genes associated with retinoic acid signaling, including NODAL and retinol dehydrogenase 10. These data indicate that genetic variation in the retinoic acid signaling pathway confers, in part, susceptibility to TAPVR.

  9. Lunar lander and return propulsion system trade study

    Science.gov (United States)

    Hurlbert, Eric A.; Moreland, Robert; Sanders, Gerald B.; Robertson, Edward A.; Amidei, David; Mulholland, John

    1993-01-01

    This trade study was initiated at NASA/JSC in May 1992 to develop and evaluate main propulsion system alternatives to the reference First Lunar Outpost (FLO) lander and return-stage transportation system concept. Thirteen alternative configurations were developed to explore the impacts of various combinations of return stage propellants, using either pressure or pump-fed propulsion systems and various staging options. Besides two-stage vehicle concepts, the merits of single-stage and stage-and-a-half options were also assessed in combination with high-performance liquid oxygen and liquid hydrogen propellants. Configurations using an integrated modular cryogenic engine were developed to assess potential improvements in packaging efficiency, mass performance, and system reliability compared to non-modular cryogenic designs. The selection process to evaluate the various designs was the analytic hierarchy process. The trade study showed that a pressure-fed MMH/N2O4 return stage and RL10-based lander stage is the best option for a 1999 launch. While results of this study are tailored to FLO needs, the design date, criteria, and selection methodology are applicable to the design of other crewed lunar landing and return vehicles.

  10. Contrast-enhanced ultrasound in portal venous system aneurysms: A multi-center study

    Science.gov (United States)

    Tana, Claudio; Dietrich, Christoph F; Badea, Radu; Chiorean, Liliana; Carrieri, Vincenzo; Schiavone, Cosima

    2014-01-01

    AIM: To investigate contrast-enhanced ultrasound (CEUS) findings in portal venous system aneurysms (PVSAs). METHODS: In this multi-center, retrospective, case series study, we evaluated CEUS features of seven cases of PVSAs that were found incidentally on conventional ultrasound in the period 2007-2013. Three Ultrasound Centers were involved (Chieti, Italy, Bad Mergentheim, Germany, and Cluj-Napoca, Romania). All patients underwent CEUS with Sonovue® (Bracco, Milan, Italy) at a standard dose of 2.4 mL, followed by 10 mL of 0.9% saline solution. The examinations were performed using multifrequency transducers and low mechanical index. We considered aneurysmal a focal dilatation of the portal venous system with a size that was significantly greater than the remaining segments of the same vein, and that was equal or larger than 21 mm for the extrahepatic segments of portal venous system, main portal vein and bifurcation, and 9 mm for the intrahepatic branches. RESULTS: After contrast agent injection, all PVSAs were not enhanced in the arterial phase (starting 8-22 s). All PVSAs were then rapidly enhanced in the early portal venous phase (starting three to five seconds after the arterial phase, 11-30 s), with persistence and slow washout of the contrast agent in the late phase (starting 120 s). In all patients, CEUS confirmed the presence of a “to-and-fro” flow by showing a swirling pattern within the dilatation in the early portal venous phase. CEUS also improved the delineation of the lumen, and was reliable in showing its patency degree and integrity of walls. In one patient, CEUS showed a partial enhancement of the lumen with a uniformly nonenhancing area in the portal venous and late phases, suggesting thrombosis. CONCLUSION: In our case series, we found that CEUS could be useful in the assessment and follow-up of a PVSA. Further studies are needed to validate its diagnostic accuracy. PMID:25561805

  11. Morpho-functional characterization of the systemic venous pole of the reptile heart

    NARCIS (Netherlands)

    Jensen, Bjarke; Vesterskov, Signe; Boukens, Bastiaan J.; Nielsen, Jan M.; Moorman, Antoon F. M.; Christoffels, Vincent M.; Wang, Tobias

    2017-01-01

    Mammals evolved from reptile-like ancestors, and while the mammalian heart is driven by a distinct sinus node, a sinus node is not apparent in reptiles. We characterized the myocardial systemic venous pole, the sinus venosus, in reptiles to identify the dominant pacemaker and to assess whether the

  12. The venous system of the pelvis: new nomenclature.

    Science.gov (United States)

    Kachlik, D; Pechacek, V; Musil, V; Baca, V

    2010-08-01

    The clinical venous anatomy of the pelvis and its veins featured a break-through during the past few years. Not only the diagnostic and therapeutical methods but also the knowledge of the functional anatomy and nomenclatures of the veins underwent substantial changes. Eleven years ago, the most recent revision of the Latin anatomical nomenclature, Terminologia Anatomica (TA, 1998) was issued. In 2004, during the 21st World Congress of the International Union of Angiology, a consensus document (under the auspices of Federative International Committee on Anatomical Terminology and International Federation of Associations of Anatomists), reflecting phlebologists' requests for new terms and replacing several insufficient ones, was accepted. Six new terms were added in both Latin and English languages in the chapter concerning the veins of the pelvis. Eponyms are not considered equal synonyms and moreover only one of them was recommended for general use. Detailed anatomy of the veins of the pelvis is discussed. This consensus document will be incorporated in the next version of the Teminologia Anatomica.

  13. Venous plethysmography

    International Nuclear Information System (INIS)

    Barnes, R.W.; Middleton, J.; Turley, D.G.

    1984-01-01

    Venous plethysmography provides an objective, versatile, and accurate method of defining those alterations that may result from acute or chronic venous disease, namely venous outflow obstruction and venous reflux through incompetent venous valves. Impedance or strain-gauge plethysmography provides the most accurate means of quantifying abnormal venous outflow in acute deep venous thrombosis. Venous volume plethysmography, using the phleborheograph, provides very sensitive determination of altered venous hemodynamics in acute deep venous thrombosis; it also serves to assess some patients with chronic venous insufficiency. Combinations of strain-gauge and photoplethysmography lead to useful measures of venous reflux in deep, perforating, and superficial veins. This information, along with measurements of maximum venous outflow, may provide the most versatile means of establishing altered hemodynamics in patients with chronic venous insufficiency

  14. The galenic venous system: Surgical anatomy and its angiographic and magnetic resonance venographic correlations

    International Nuclear Information System (INIS)

    Kilic, Tuerker; Ozduman, Koray; Cavdar, Safiye; Oezek, M. Memet; Pamir, M. Necmettin

    2005-01-01

    Objective: This study aims at evaluating the adequacy of digital subtraction angiography and magnetic resonance venography in imaging of the galenic venous system for surgical planning of approaches to the pineal region. Anatomical dissections were carried out in 10 cadavers of several age groups and these were compared to imaging findings in 10 living subjects. Methods: The presence or absence of 10 predetermined veins or vein groupings belonging to the galenic venous system were prospectively analyzed in 10 cadaver dissections and imaging findings of 10 age matched human subjects. The studied vessels were the vein of galen, the internal cerebral veins, both basal vein of Rosenthals, internal occipital vein, occipitotemporal veins, precentral cerebellar veins, tectal veins, pineal veins, superior vermian veins (including superior cerebellar veins (SCVs)) and posterior pericallosal veins. Each of the subjects had both digital subtraction angiography and magnetic resonance venography studies performed. Diagnostic digital subtraction angiography was performed using the transfemoral route and the venous phase was used for the study. Magnetic resonance venography was performed in 1.5 T MRI equipment using the 2D-TOF sequence. All studies were reported to be normal. Results: There was wide variation in the anatomy of the galenic venous system. There were interpersonal, intrapersonal and age related variations. Both the digital subtraction angiography and the magnetic resonance venography were efficient at demonstrating large veins. However, smaller veins were less readily demonstrated in either study. The general sensitivities of the digital subtraction angiography and the magnetic resonance venography for the galenic venous system were 45.5% and 32.5%, respectively. Surgically important veins were missed in most studies. Conclusions: Anatomically, the galenic venous system is highly variable. This variability is caused by interpersonal, intrapersonal and age related

  15. Visualization of the renal venous system by renal arteriography with digital subtraction angiography

    International Nuclear Information System (INIS)

    Nagai, Jun

    1989-01-01

    The purpose of this study was to obtain vivid and precise images of intrarenal venous branching using DSA for renal arteriography. The type of system used was an ADAC DPS-4100C with 70-80 kVp, and 320 mA, 25-50 msec at 6 frames/sec. The duration was 10 sec and the matrix size was 512x512. In order to retain clear subtracted images of intrarenal venous branching with minimal noise the three frames were selected on the time-density curve of DSA: (Fig.3). 1) a frame on which renal arteries disappear (frame X), 2) the frame with highest renal venous density value as (frame Y), 3) the difference of the nephrogram density between X and Y frames in which only the density of the nephrogram decreases (frame Z). The mask image is the image subtracted by the equation of the weighted averaging method on X and Z frame and is subtracted from the image of Y frame in the final step. By this method, 40 kidneys in 36 patients were studied, and the intrarenal venous branches up to the interlobar vein was clearly demonstrated in 28 of these cases (70%). This method is useful to estimate the extent of intrarenal lesions and detect abnormal renal blood flow compared with conventional temporal subtraction method. (author)

  16. Passive vs. Parachute System Architecture for Robotic Sample Return Vehicles

    Science.gov (United States)

    Maddock, Robert W.; Henning, Allen B.; Samareh, Jamshid A.

    2016-01-01

    The Multi-Mission Earth Entry Vehicle (MMEEV) is a flexible vehicle concept based on the Mars Sample Return (MSR) EEV design which can be used in the preliminary sample return mission study phase to parametrically investigate any trade space of interest to determine the best entry vehicle design approach for that particular mission concept. In addition to the trade space dimensions often considered (e.g. entry conditions, payload size and mass, vehicle size, etc.), the MMEEV trade space considers whether it might be more beneficial for the vehicle to utilize a parachute system during descent/landing or to be fully passive (i.e. not use a parachute). In order to evaluate this trade space dimension, a simplified parachute system model has been developed based on inputs such as vehicle size/mass, payload size/mass and landing requirements. This model works in conjunction with analytical approximations of a mission trade space dataset provided by the MMEEV System Analysis for Planetary EDL (M-SAPE) tool to help quantify the differences between an active (with parachute) and a passive (no parachute) vehicle concept.

  17. The Anatomical Correlation between the Internal Venous Vertebral System and the Cranial Venae Cavae in Rabbit.

    Science.gov (United States)

    Mazensky, David; Petrovova, Eva; Danko, Jan

    2013-01-01

    The aim of this study was to describe the possible variations in the connection between the internal venous vertebral system and the cranial vena cava in rabbit using corrosion technique. The study was carried out on 40 adult New Zealand white rabbits. The venous system was injected by using Batson's corrosion casting kit number 17. We found the connection between the internal venous vertebral system and the cranial vena cava by means of the vertebral veins and the right azygos vein. The vertebral vein was present as independent tributary in 36 cases (90%). In the rest of the cases, it was found as being double, being triple, or forming a common trunk with other veins. The azygos vein was present as independent tributary of the cranial vena cava in 39 cases (97.5%). We found also a common trunk formed by the junction of the deep cervical vein, the right vertebral vein, and the azygos vein in one case (2.5%). The azygos vein received 6, 7, 8, or 9 pairs of dorsal intercostal veins. Documenting the anatomical variations in the rabbit will aid in the planning of future experimental studies and determining the clinical relevance on such studies.

  18. The Anatomical Correlation between the Internal Venous Vertebral System and the Cranial Venae Cavae in Rabbit

    Directory of Open Access Journals (Sweden)

    David Mazensky

    2013-01-01

    Full Text Available The aim of this study was to describe the possible variations in the connection between the internal venous vertebral system and the cranial vena cava in rabbit using corrosion technique. The study was carried out on 40 adult New Zealand white rabbits. The venous system was injected by using Batson's corrosion casting kit number 17. We found the connection between the internal venous vertebral system and the cranial vena cava by means of the vertebral veins and the right azygos vein. The vertebral vein was present as independent tributary in 36 cases (90%. In the rest of the cases, it was found as being double, being triple, or forming a common trunk with other veins. The azygos vein was present as independent tributary of the cranial vena cava in 39 cases (97.5%. We found also a common trunk formed by the junction of the deep cervical vein, the right vertebral vein, and the azygos vein in one case (2.5%. The azygos vein received 6, 7, 8, or 9 pairs of dorsal intercostal veins. Documenting the anatomical variations in the rabbit will aid in the planning of future experimental studies and determining the clinical relevance on such studies.

  19. Two-dimensional phase contrast MR angiography of the venous system of lower extremities

    International Nuclear Information System (INIS)

    Hashimoto, Hiromi; Nakatsuka, Haruki; Tsubakimoto, Mitsuo

    1994-01-01

    Two-dimensional phase contrast MR angiography (MRA) was performed in 10 healthy volunteers and 14 patients in whom deep venous occlusion was clinically suspected. In all volunteers, MRA demonstrated bilateral great saphenous veins, superficial femoral veins and popliteal veins. Deep veins in the calves were visualized in only 3 of 20 legs (15%) examined, but after applying tourniquets above the knee, they were visualized in 6 of 8 legs (75%). In 5 of 8 patients whose lower extremities were swollen, deep vein occlusions were diagnosed by MRA and in 4 patients deep vein thrombosis was confirmed by computed tomography or conventional venography. In the other 3 patients whose lower extremities were swollen and in 6 patients whose lower extremities were not swollen but who had varicose veins, MRA demonstrated patency of the deep veins. It is concluded that MRA is a non-invasive useful diagnostic technique for evaluating patency of the deep venous system of the lower extremities. (author)

  20. Two-dimensional phase contrast MR angiography of the venous system of lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Hiromi; Nakatsuka, Haruki; Tsubakimoto, Mitsuo (Itami City Hospital, Hyogo (Japan)) (and others)

    1994-01-01

    Two-dimensional phase contrast MR angiography (MRA) was performed in 10 healthy volunteers and 14 patients in whom deep venous occlusion was clinically suspected. In all volunteers, MRA demonstrated bilateral great saphenous veins, superficial femoral veins and popliteal veins. Deep veins in the calves were visualized in only 3 of 20 legs (15%) examined, but after applying tourniquets above the knee, they were visualized in 6 of 8 legs (75%). In 5 of 8 patients whose lower extremities were swollen, deep vein occlusions were diagnosed by MRA and in 4 patients deep vein thrombosis was confirmed by computed tomography or conventional venography. In the other 3 patients whose lower extremities were swollen and in 6 patients whose lower extremities were not swollen but who had varicose veins, MRA demonstrated patency of the deep veins. It is concluded that MRA is a non-invasive useful diagnostic technique for evaluating patency of the deep venous system of the lower extremities. (author).

  1. Engineered Geothermal Systems Energy Return On Energy Investment

    Energy Technology Data Exchange (ETDEWEB)

    Mansure, A J

    2012-12-10

    Energy Return On Investment (EROI) is an important figure of merit for assessing the viability of energy alternatives. Too often comparisons of energy systems use efficiency when EROI would be more appropriate. For geothermal electric power generation, EROI is determined by the electricity delivered to the consumer compared to the energy consumed to construct, operate, and decommission the facility. Critical factors in determining the EROI of Engineered Geothermal Systems (EGS) are examined in this work. These include the input energy embodied into the system. Embodied energy includes the energy contained in the materials, as well as, that consumed in each stage of manufacturing from mining the raw materials to assembling the finished system. Also critical are the system boundaries and value of the energy heat is not as valuable as electrical energy. The EROI of an EGS depends upon a number of factors that are currently unknown, for example what will be typical EGS well productivity, as well as, reservoir depth, temperature, and temperature decline rate. Thus the approach developed is to consider these factors as parameters determining EROI as a function of number of wells needed. Since the energy needed to construct a geothermal well is a function of depth, results are provided as a function of well depth. Parametric determination of EGS EROI is calculated using existing information on EGS and US Department of Energy (DOE) targets and is compared to the minimum EROI an energy production system should have to be an asset rather than a liability.

  2. Diagnosis of venous disorders

    International Nuclear Information System (INIS)

    Minar, E.

    1993-01-01

    Limited accuracy in the clinic diagnosis of deep vein thrombosis (VT) makes such diagnostic tests such as duplex sonography or venography necessary. Exact information on the age and extent of the thrombus are necessary for the clinician to optimize the therapeutric management. The correct diagnosis of calf vein thrombosis and of recurrent VT in patients with postphlebitis changes also has implications for treatment. After exclusion of thrombosis, the radiologist should evaluate the leg for other possible causes of symptoms besides VT. Investigation of the venous sytem also has a role in the diagnosis in patients with suspected pulmonary embolism. In patients with chronic venous insuffficiency the deep venous system should assessed for patency and venous valve function. The superficial veins should be differentiated in segments with sufficient or insufficient venous valves, and it is also necessary to look for insufficiency of the perforrating veins. In patients with superficial phlebitis there is risk of propagation into the deep venous system. (orig.) [de

  3. OPTIMAL PREVENTION OF HOSPITAL VENOUS THROMBOEMBOLISM WITH THE HELP OF MEDICAL INFORMATION SYSTEM

    Directory of Open Access Journals (Sweden)

    G. I. Nazarenko

    2014-01-01

    Full Text Available Deep vein thrombosis and pulmonary embolism are an important medical and social problem, contributing to the structure of morbidity and mortality in the developed countries. Despite the availability of clinical guidelines for the prevention of venous thromboembolic complications there is a gap between scientific knowledge and clinical practice. Clinical decision support systems (CDSS are confirmed to be effective tool for the implementation of clinical guidelines in daily practice. CDSS should be based on national and international clinical guidelines; their effectiveness depends upon successful integration with other health information systems and care flow processes.

  4. Clarifying the anatomy and physiology of totally anomalous systemic venous connection.

    Science.gov (United States)

    Gupta, Saurabh Kumar; Juneja, Rajnish; Anderson, Robert H; Gulati, Gurpreet S; Devagorou, Velayoudam

    2017-01-01

    The description of totally anomalous systemic venous connection is limited to case reports. In this review, we seek to clarify anatomic, physiologic, and hemodynamic aspects of this extremely rare anomaly. We also present findings of two patients in whom connection of all the systemic veins was anomalous. In the first patient, with usual atrial arrangement, all systemic veins, including the coronary sinus, were connected anomalously to the morphologically left atrium. Limited left-to-right shunt across an atrial septal defect provided the only source of blood flow to the lungs. The diagnosis was established by saline contrast echocardiography and cardiac catheterization. Extreme hypoplasia of the right ventricle precluded corrective surgery, so we performed a bidirectional Glenn operation, along with atrial septectomy. The second patient had isomerism of the left atrial appendages, which creates problems in the definition in anatomic terms since the connection of the systemic veins can never be normal anatomically when both atriums possess a morphologically left appendage. Our patient, nonetheless, had all the systemic and pulmonary veins, connected to the left-sided atrial chamber which then connected to the left ventricle, thus producing hemodynamics of totally anomalous systemic venous connection. We propose an algorithm for evaluation of this hemodynamic combination and discuss management options. We also intend to clarify the potential differences between connection and drainage, with particular attention to the arrangement of atrial appendages. Even though the hemodynamics may be comparable, in anatomic terms, both systemic and pulmonary venoatrial connection will always be anomalous with isomeric atrial appendages.

  5. Thermalization and Return to Equilibrium on Finite Quantum Lattice Systems.

    Science.gov (United States)

    Farrelly, Terry; Brandão, Fernando G S L; Cramer, Marcus

    2017-04-07

    Thermal states are the bedrock of statistical physics. Nevertheless, when and how they actually arise in closed quantum systems is not fully understood. We consider this question for systems with local Hamiltonians on finite quantum lattices. In a first step, we show that states with exponentially decaying correlations equilibrate after a quantum quench. Then, we show that the equilibrium state is locally equivalent to a thermal state, provided that the free energy of the equilibrium state is sufficiently small and the thermal state has exponentially decaying correlations. As an application, we look at a related important question: When are thermal states stable against noise? In other words, if we locally disturb a closed quantum system in a thermal state, will it return to thermal equilibrium? We rigorously show that this occurs when the correlations in the thermal state are exponentially decaying. All our results come with finite-size bounds, which are crucial for the growing field of quantum thermodynamics and other physical applications.

  6. Return to play in elite rugby union: application of global positioning system technology in return-to-running programs.

    Science.gov (United States)

    Reid, Laura C; Cowman, Jason R; Green, Brian S; Coughlan, Garrett F

    2013-05-01

    Global positioning systems (GPS) are widely used in sport settings to evaluate the physical demands on players in training and competition. The use of these systems in the design and implementation of rehabilitation and return-to-running programs has not yet been elucidated. To demonstrate the application of GPS technology in the management of return to play in elite-club Rugby Union. Case series. Professional Rugby Union club team. 8 elite Rugby Union players (age 27.86 ± 4.78 y, height 1.85 ± 0.08 m, weight 99.14 ± 9.96 kg). Players wore GPS devices for the entire duration of a club game. Variables of locomotion speed and distance were measured. Differences in physical demands between playing positions were observed for all variables. An analysis of the position-specific physical demands measured by GPS provides key information regarding the level and volume of loads sustained by a player in a game environment. Using this information, sports-medicine practitioners can develop rehabilitation and return-to-running protocols specific to the player position to optimize safe return to play.

  7. A optimization model for product returns using genetic algorithms and artificial immune system

    DEFF Research Database (Denmark)

    Diabat, Ali; Kannan, Devika; Kaliyan, Mathiyazhagan

    2013-01-01

    is developed to find out the number and location of initial collection points and centralized return centers required for an effective return and collection system, and also the maximum holding time (collection frequency) for aggregation of small volumes of returned products into large shipments. Two solution...

  8. Partial Anomalous Pulmonary Venous Return via a Levoatriocardinal Vein in Association with Rheumatic Mitral Stenosis: MR Demonstration and Successful Surgical Repair

    International Nuclear Information System (INIS)

    Hyun, Dong Ho; Chae, Eun Jin; Seo, Joon Beom; Kang, Joon Won; Do, Kyung Hyun; Lee, Choong Wook; Lee, Hyun Joo; Hwang, Hye Jeon; Lim, Tae Hwan

    2010-01-01

    The preoperative evaluation of the hemodynamics associated with PAPVR and rheumatic mitral valve stenosis is necessary for successful surgical treatment, even though the incidence rate is rare. The purpose of this case report is to present the usefulness of CT and MRI for diagnosing rheumatic mitral stenosis and partial anomalous pulmonary venous connection to the left innominate vein accompanied by the presence of the levoatriocardinal vein and evaluating its flow dynamics

  9. [The development of the cerebral venous system--from the embryo to the adult definitive structure].

    Science.gov (United States)

    Lopes, Leonor; Palma, Teresa; Cravo, Isabel; Gonçalves, Cristina; Bousende, Marco; Martins Pisco, João

    2012-01-01

    The human development consists of a continuous process where an uninterrupted pattern of extremely complex repetitive cycles of growth, modulation and modification take place. Despite this extreme complexity, the normal development is ordered by an impressive regularity, namely, in chronological, anatomical, topographic and physiological trends. In some organic systems, this development will not be totally ended by the time of birth. In this situation, further changes will have to take place until the adult definitive pattern is achieved. The cerebral venous system (CVS) is such a paradigm. The authors pretend to present a synopsis of the specific organogenesis of the cerebral venous system in order to allow a correct interpretation of the vascular structures, recognise the anatomical variations and better comprehend the topographic correlations between neighbouring structures. Following a structured and synthetic order, the main guiding lines of the principal evolutional steps will be presented from the first embryological stages until the final and definitive adult pattern. The detailed study of the continuous development stages of the CVS constitutes a fundamental tool for the whole recognition of the anatomical structures, their correct interpretation and detection of possible variants as well as a better comprehension of topographic relationship between neighbouring structures. In other words and following KL Moore, Embryology illuminates anatomy.

  10. [Return migrations in the Italian migration system: a reexamination].

    Science.gov (United States)

    Bonifazi, C; Heins, F

    1996-06-01

    The authors discuss trends in return migration in Italy, with a focus on regional differences. "On a regional level, the effects of return migration are very much connected with socio-economic structure. Only highly developed and autonomous regions can absorb productive investments and changes brought about by return migration. Several southern regions--especially those with greater migration experience--have shown in the last decades a very poor socio-economic development." The study is concerned with both internal and international migration. (SUMMARY IN ENG AND FRE) excerpt

  11. System for Packaging Planetary Samples for Return to Earth

    Science.gov (United States)

    Badescu, Mircea; Bar-Cohen, Yoseph; Backes, paul G.; Sherrit, Stewart; Bao, Xiaoqi; Scott, James S.

    2010-01-01

    A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

  12. On-Board Pressurization Systems for Sample Return Missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To-date, the realization of high-performance liquid bipropellant rocket engines for ascent vehicle and sample return applications has largely been hindered by the...

  13. Venous System in Acute Brain Injury: Mechanisms of Pathophysiological Change and Function

    Science.gov (United States)

    Xu, Liang; Matei, Nathanael; Tang, Jiping; Feng, Hua; Zhang, JohnH

    2015-01-01

    Cerebral vascular injury is a major component of acute brain injury. Currently, neuroprotective strategies primarily focus on the recanalization of cerebral arteries and capillaries, and the protection of insulted neurons. Hitherto, the role of vein drainage in the pathophysiology of acute brain injury has been overlooked, due to an under appreciation of the magnitude of the impact of veins in circulation. In this review, we summarize the changes in the vein morphology and functions that are known, or likely to occur related to acute brain injury, and aim to advance the therapeutic management of acute brain injury by shifting the focus from reperfusion to another term: recirculation. Recent progress in the neurobiological understanding of the vascular neural network has demonstrated that cerebral venous systems are able to respond to acute brain injury by regulating the blood flow disharmony following brain edema, blood brain barrier disruption, ischemia, and hemorrhage. With the evidence presented in this review, future clinical management of acutely brain injured patients will expand to include the recirculation concept, establishing a harmony between arterial and venous systems, in addition to the established recanalization and reperfusion strategies. PMID:25783658

  14. Venous responses during exercise in rainbow trout, Oncorhynchus mykiss : [alpha]-adrenergic control and the antihypotensive function of the renin-angiotensin system

    DEFF Research Database (Denmark)

    Sandblom, E.; Axelsson, M.; McKenzie, David

    2006-01-01

    The role of the [alpha]-adrenergic system in the control of cardiac preload (central venous blood pressure; Pven) and venous capacitance during exercise was investigated in rainbow trout (Oncorhynchus mykiss). In addition, the antihypotensive effect of the renin-angiotesin system (RAS...... trout. It is also the first study to suggest that the RAS may be an important modulator of venous pressure and capacitance in fish....

  15. Clarifying the anatomy and physiology of totally anomalous systemic venous connection

    Directory of Open Access Journals (Sweden)

    Saurabh Kumar Gupta

    2017-01-01

    Full Text Available The description of totally anomalous systemic venous connection is limited to case reports. In this review, we seek to clarify anatomic, physiologic, and hemodynamic aspects of this extremely rare anomaly. We also present findings of two patients in whom connection of all the systemic veins was anomalous. In the first patient, with usual atrial arrangement, all systemic veins, including the coronary sinus, were connected anomalously to the morphologically left atrium. Limited left-to-right shunt across an atrial septal defect provided the only source of blood flow to the lungs. The diagnosis was established by saline contrast echocardiography and cardiac catheterization. Extreme hypoplasia of the right ventricle precluded corrective surgery, so we performed a bidirectional Glenn operation, along with atrial septectomy. The second patient had isomerism of the left atrial appendages, which creates problems in the definition in anatomic terms since the connection of the systemic veins can never be normal anatomically when both atriums possess a morphologically left appendage. Our patient, nonetheless, had all the systemic and pulmonary veins, connected to the left-sided atrial chamber which then connected to the left ventricle, thus producing hemodynamics of totally anomalous systemic venous connection. We propose an algorithm for evaluation of this hemodynamic combination and discuss management options. We also intend to clarify the potential differences between connection and drainage, with particular attention to the arrangement of atrial appendages. Even though the hemodynamics may be comparable, in anatomic terms, both systemic and pulmonary venoatrial connection will always be anomalous with isomeric atrial appendages.

  16. DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects

    Directory of Open Access Journals (Sweden)

    Fischer Roland

    2017-09-01

    Full Text Available Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.

  17. Hepatic venous outflow block in a young patient with Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Ali Ghavidel

    2015-08-01

    Full Text Available Introduction: Hepatic venous outflow block or Budd-Chiari syndrome is a severe liver disease with a 3 years survival rate of 50%. Several conditions have been implicated as a cause of Budd-Chiari syndrome, including myeloproliferative disorders, paroxysmal nocturnal hemoglobinuria, the presence of lupus anti-coagulant, oral contraceptives, pregnancy, and others. In a small number of cases, Budd-Chiari syndrome is associated with the presence of lupus anticoagulant. Anticardiolipin antibodies (ACA are similar to lupus anti-coagulant antiphospholipid antibodies (APLAs, which have been described in patients with recurrent arterial and venous thrombosis, thrombocytopenia, fetal loss, or miscarriage. Case Report: A 23-year-old woman is reported with Budd-Chiari syndrome in whom lupus anticoagulant and anticardiolipin antibodies were shown; 9 months after diagnosis of systemic lupus erythematosus (SLE treatment with steroids admitted with gastrointestinal problems, abdominal pain and ascites and treated oral anticoagulants induced a considerable improvement. This treatment was continued after 1 year, but interruption was followed by redevelopment of ascites. Further treatment with anticoagulants was continued for 5 years with noticeable improvement. Conclusion: Patients with Budd-Chiari syndrome should be tested for lupus anticoagulants and anticardiolipin antibodies, Budd-Chiari syndrome resulting from this cause may have a good response to treatment with oral anticoagulants; this treatment should be maintained permanently, and pregnancy in such patients may initiate serious difficulties. The condition of the patient at follow-up was good.

  18. THE RETURN ON EQUITY INDICATORS SYSTEM – METHODOLOGICAL PROPOSAL

    Directory of Open Access Journals (Sweden)

    Zbigniew Gołaś

    2015-06-01

    Full Text Available The aim of the study was to present a suggestion for the methodical decomposition rate of return on equity (ROE. The developed ROE decomposition model includes nine factors: the rate of value added, the rate of depreciation costs, salaries expense ratio, the ratio of other operating income and expenses, the rate of fi nancial income and expenses, the rate of extraordinary events, the rate of tax, the assets rotation and capital gearing. In addition, based on deterministic methods, the study presents the analysis of changes in the level of return on equity on the example of the domestic furniture manufacturing sector in the period 2009–2013.

  19. Evaluation of the portal venous system using MR angiography in patients with severe liver dysfunction

    International Nuclear Information System (INIS)

    Fukatsu, Hiroshi; Ando, Yoko; Yamakawa, Koji; Ishigaki, Takeo

    1994-01-01

    Fifteen patients of chronic liver dysfunction were examined with 2D TOF MR angiography to assess the portal venous system condition. All of the collateral pathways except esophageal varices were clearly demonstrated in all cases, portal vein thromboses were accurately diagnosed in two cases. Portal vein visualization index were determined as follows: good delineation of the main portal vein only; good delineation of the first tributaries of the intrahepatic portal vein; good delineation of the second or further tributaries. This index showed good correlation with the clinical stage proposed by Japan liver cancer study group. These results suggested that MR angiography has a potential for the evaluation of the portal system in patients with severe liver dysfunction. (author)

  20. Congenital anomalous/aberrant systemic artery to pulmonary venous fistula: Closure with vascular plugs & coil embolization

    Directory of Open Access Journals (Sweden)

    Pankaj Jariwala

    2014-01-01

    Full Text Available A 7-month-old girl with failure to thrive, who, on clinical and diagnostic evaluation [echocardiography & CT angiography] to rule out congenital heart disease, revealed a rare vascular anomaly called systemic artery to pulmonary venous fistula. In our case, there was dual abnormal supply to the entire left lung as1 anomalous supply by normal systemic artery [internal mammary artery]2 and an aberrant feeder vessel from the abdominal aorta. Left Lung had normal bronchial connections and normal pulmonary vasculature. The fistula drained through the pulmonary veins to the left atrium leading to ‘left–left shunt’. Percutaneous intervention in two stages was performed using Amplatzer vascular plugs and coil embolization to close them successfully. The patient gained significant weight in follow up with other normal developmental and mental milestones.

  1. Impact of systemic risk in the real estate sector on banking return.

    Science.gov (United States)

    Li, Shouwei; Pan, Qing; He, Jianmin

    2016-01-01

    In this paper, we measure systemic risk in the real estate sector based on contingent claims analysis, and then investigate its impact on banking return. Based on the data in China, we find that systemic risk in the real estate sector has a negative effect on banking return, but this effect is temporary; banking risk aversion and implicit interest expense have considerable impact on banking return.

  2. Venous responses during exercise in rainbow trout, Oncorhynchus mykiss : [alpha]-adrenergic control and the antihypotensive function of the renin-angiotensin system

    DEFF Research Database (Denmark)

    Sandblom, E.; Axelsson, M.; McKenzie, David

    2006-01-01

    The role of the [alpha]-adrenergic system in the control of cardiac preload (central venous blood pressure; Pven) and venous capacitance during exercise was investigated in rainbow trout (Oncorhynchus mykiss). In addition, the antihypotensive effect of the renin-angiotesin system (RAS) was invest...

  3. [Venous ulcer].

    Science.gov (United States)

    Böhler, Kornelia

    2016-06-01

    Venous disorders causing a permanent increase in venous pressure are by far the most frequent reason for ulcers of the lower extremity. With a prevalence of 1 % in the general population rising to 4 % in the elderly over 80 and its chronic character, 1 % of healthcare budgets of the western world are spent on treatment of venous ulcers. A thorough investigation of the underlying venous disorder is the prerequisite for a differenciated therapy. This should comprise elimination of venous reflux as well as local wound management. Chronic ulcers can successfully be treated by shave therapy and split skin grafting. Compression therapy is a basic measure not only in venous ulcer treatment but also in prevention of ulcer recurrence. Differential diagnosis which have to be considered are arterial ulcers, vasculitis and neoplasms.

  4. Varicocele, hypoxia and male infertility. Fluid Mechanics analysis of the impaired testicular venous drainage system.

    Science.gov (United States)

    Gat, Yigal; Zukerman, Zvi; Chakraborty, Joana; Gornish, Michael

    2005-09-01

    Varicocele is a bilateral vascular disease, involving a network of collaterals and small, retroperitoneal bypasses. The right and the left testicular venous drainage systems are complex and not identical to each other. It was considered a predominantly unilateral (left-sided) disease. Its pathophysiology has not been clearly delineated and the treatments offered do not seem to be effective. The medical literature is replete with articles demonstrating inconsistent and even contradictory results which have led clinicians to dissociate varicocele from male infertility. Since male fertility is preserved with only one healthy testis, male infertility perforce represents bilateral testicular dysfunction. This poses an enigma to clinicians: How can left-sided varicocele causes bilateral testicular dysfunction? We investigated the internal spermatic veins by venography to understand testicular damage due to varicocele. A total of 740 venographies of the internal spermatic veins (ISVs) were performed, with sclerotherapy of the ISV as treatment for varicocele. Epon-embedded testicular tissue sections were used to identify blood stagnation in the testis. Varicocele is predominantly a bilateral disease in 84% of cases, associated with collaterals and retroperitoneal venous bypasses in 70% in the left side and 75% in the right side. Histopathology demonstrate stagnation in the testicular microcirculation and hypoxic-ischaemic degenerative changes in all cells' types in the sperms' production site. Based on our findings (i) varicocele is a bilateral disease; (ii) the disease is expressed earlier in the left side and is more intense because the blood column is longer in the left side than the right; (iii) partial treatment to the left side only and ignoring bypasses is not adequate to correct the problem; (iv) hypoxia leading to ischaemic damage to both testes is the effect of varicocele due to hydrostatic pressures in the impaired venous drainage system, which exceeds the

  5. Research progress of cerebral venous system diseases and cerebral small vessel disease: Chinese scholars' reports published abroad

    Directory of Open Access Journals (Sweden)

    Tian CAO

    2016-11-01

    Full Text Available In recent years, Chinese scholars have published several high-quality articles on cerebral venous system diseases and cerebral small vessel disease (cSVD in foreign professional journals, covering new imaging techniques for diagnosis and differential diagnosis of cerebral venous thrombosis (CVT, combination therapy in severe CVT, influencing factors of cSVD, detection methods and treatment exploration, etc. In this review, we briefly outline the data on their studies. DOI: 10.3969/j.issn.1672-6731.2016.11.005

  6. Superior vena cava syndrome associated with right-to left shunt through systemic-to-pulmonary venous collaterals

    International Nuclear Information System (INIS)

    Juan, Yu Hsiang; Saboo, Sachin S.; Anand, Vishal; Chatzizisis, Yiannis S.; Steigner, Michael L.; Lin, Yu Ching

    2014-01-01

    Superior vena cava (SVC) obstruction is associated with the gradual development of venous collaterals. We present a rare form of systemic-to-pulmonary subpleural collateral pathway that developed in the bridging subpleural pulmonary veins in a 54-year-old woman with complete SVC obstruction. This uncommon collateral pathway represents a rare form of acquired right-to-left shunt due to previous pleural adhesions with an increased risk of stroke due to right-to-left venous shunting, which requires lifelong anticoagulation.

  7. An Integrated Tool for System Analysis of Sample Return Vehicles

    Science.gov (United States)

    Samareh, Jamshid A.; Maddock, Robert W.; Winski, Richard G.

    2012-01-01

    The next important step in space exploration is the return of sample materials from extraterrestrial locations to Earth for analysis. Most mission concepts that return sample material to Earth share one common element: an Earth entry vehicle. The analysis and design of entry vehicles is multidisciplinary in nature, requiring the application of mass sizing, flight mechanics, aerodynamics, aerothermodynamics, thermal analysis, structural analysis, and impact analysis tools. Integration of a multidisciplinary problem is a challenging task; the execution process and data transfer among disciplines should be automated and consistent. This paper describes an integrated analysis tool for the design and sizing of an Earth entry vehicle. The current tool includes the following disciplines: mass sizing, flight mechanics, aerodynamics, aerothermodynamics, and impact analysis tools. Python and Java languages are used for integration. Results are presented and compared with the results from previous studies.

  8. 4D flow MR imaging of the portal venous system: a feasibility study in children

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, Keyur; Rose, Michael; Popescu, Andrada; Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); McCormick School of Engineering, Northwestern University, Department of Biomedical Engineering, Chicago, IL (United States); Schnell, Susanne [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States)

    2017-02-15

    To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. (orig.)

  9. 4D flow MR imaging of the portal venous system: a feasibility study in children

    International Nuclear Information System (INIS)

    Parekh, Keyur; Rose, Michael; Popescu, Andrada; Rigsby, Cynthia K.; Markl, Michael; Schnell, Susanne

    2017-01-01

    To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. (orig.)

  10. Advanced Ignition System for Hybrid Rockets for Sample Return Missions, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To return a sample from the surface of Mars or any of the larger moons in the solar system will require a propulsion system with a comparatively large delta-V...

  11. Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

    Science.gov (United States)

    Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther

    2006-12-01

    The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

  12. Anatomical reconstructions of the human cardiac venous system using contrast-computed tomography of perfusion-fixed specimens.

    Science.gov (United States)

    Spencer, Julianne; Fitch, Emily; Iaizzo, Paul A

    2013-04-18

    A detailed understanding of the complexity and relative variability within the human cardiac venous system is crucial for the development of cardiac devices that require access to these vessels. For example, cardiac venous anatomy is known to be one of the key limitations for the proper delivery of cardiac resynchronization therapy (CRT)(1) Therefore, the development of a database of anatomical parameters for human cardiac venous systems can aid in the design of CRT delivery devices to overcome such a limitation. In this research project, the anatomical parameters were obtained from 3D reconstructions of the venous system using contrast-computed tomography (CT) imaging and modeling software (Materialise, Leuven, Belgium). The following parameters were assessed for each vein: arc length, tortuousity, branching angle, distance to the coronary sinus ostium, and vessel diameter. CRT is a potential treatment for patients with electromechanical dyssynchrony. Approximately 10-20% of heart failure patients may benefit from CRT(2). Electromechanical dyssynchrony implies that parts of the myocardium activate and contract earlier or later than the normal conduction pathway of the heart. In CRT, dyssynchronous areas of the myocardium are treated with electrical stimulation. CRT pacing typically involves pacing leads that stimulate the right atrium (RA), right ventricle (RV), and left ventricle (LV) to produce more resynchronized rhythms. The LV lead is typically implanted within a cardiac vein, with the aim to overlay it within the site of latest myocardial activation. We believe that the models obtained and the analyses thereof will promote the anatomical education for patients, students, clinicians, and medical device designers. The methodologies employed here can also be utilized to study other anatomical features of our human heart specimens, such as the coronary arteries. To further encourage the educational value of this research, we have shared the venous models on our

  13. Ectatic and Occlusive Diseases of the Venous Drainage System of Cerebral Arteriovenous Malformations (AVMs) - with Emphasis on Spectacular Shrinking Neurological Deficits after Embolization.

    Science.gov (United States)

    Goto, K

    2005-10-05

    During reviewing cases with AVM, the author noticed that stenotic and occlusive changes of the draining veins are commonly seen in high flow cerebral AVMs. However, little attention has been paid to these venous diseases until ectatic veins, generated in the upstream of the venous system, cause mass effect to the surrounding structures, or redistribution and shunting toward regional veins became insufficient after they are markedly overloaded or occluded. Cases with such venous abnormality are clinically important because of the possibility of dramatic improvement of neurological deficits after embolization of AVMs. Following presenting treatment results of 177 AVM case, the author is going to present five cases with abnormality in the Galenic venous system and two cases with abnormality in cortical veins associating with high flow cerebral AVMs. Consideration will be made on symptomatology and pathophysiologic mechanism of venous abnormalities associating with high flow cerebral AVMs.

  14. [Developmental venous anomaly (DVA)].

    Science.gov (United States)

    Zimmer, A; Hagen, T; Ahlhelm, F; Viera, J; Reith, W; Schulte-Altedorneburg, G

    2007-10-01

    As congenital anatomic variants of venous drainage, developmental venous anomalies (DVA) represent up to 60% of all cerebral vascular malformations. The prior term "venous angioma" is a misnomer implicating an abnormal vascular structure with an increased bleeding risk. They are often found incidentally and are hardly ever symptomatic. Their morphologic characteristics are dilated vessels in the white matter, which converge on a greater collector vein, forming the typical caput medusae. They drain into the superficial or deep venous system. The frequent association with other, potentially bleeding-prone vascular malformations is clinically relevant, in particular cavernous angioma, which might require therapeutic action. Therefore, coincident vascular lesions need to be actively sought by appropriate additional imaging techniques.

  15. Venous insufficiency

    Science.gov (United States)

    ... a large vein in the leg called the superficial saphenous vein. Outlook (Prognosis) Chronic venous insufficiency tends ... the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein should ...

  16. Venous Ulcers

    Science.gov (United States)

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  17. Return Migrants’ Experience of Access to Care in Corrupt Healthcare Systems

    DEFF Research Database (Denmark)

    Handlos, Line Neerup; Olwig, Karen Fog; Bygbjerg, Ib Christian

    2016-01-01

    Equal and universal access to healthcare services is a core priority for a just health system. A key societal determinant seen to create inequality in access to healthcare is corruption in the healthcare system. How return migrants’ access to healthcare is affected by corruption is largely unstud...... them sidestep the corruption. Returned refugees are thus particularly vulnerable to the effects of corruption.......Equal and universal access to healthcare services is a core priority for a just health system. A key societal determinant seen to create inequality in access to healthcare is corruption in the healthcare system. How return migrants’ access to healthcare is affected by corruption is largely...... unstudied, even though return migrants may be particularly vulnerable to problems related to corruption due to their period of absence from their country of origin. This article investigates how corruption in the healthcare sector affects access to healthcare for refugees who repatriated to Bosnia...

  18. O2/CO Ignition System for Mars Sample Return Missions, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Returning a geological sample from the surface of Mars will require an ascent propulsion system with a comparatively large velocity change (delta-V) capability due...

  19. O2/CO Ignition System for Mars Sample Return Missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Returning a geological sample from the surface of Mars will require an ascent propulsion system with a comparatively large velocity change (delta-V) capability due...

  20. Venous thromboses

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, A.; Tosch, U.; Rath, M.

    1985-02-01

    The suspicion of the presence of venous thrombosis is supported by Doppler-sonography. The crucial diagnostic procedure, however, is the conventional x-ray-phlebography. The digital subtraction phlebography adds to the conventional technique in the pelvic and thoracic area if parts of the skeleton or soft tissue are overlapping. The radionuclid-phlebography will be applied in contrast medium incompatibility or in suspicion of pulmonary embolism. Factors of increased prevalence of venous thrombosis can be confirmed by CT or sonography.

  1. Return Migrants? Experience of Access to Care in Corrupt Healthcare Systems: The Bosnian Example

    OpenAIRE

    Neerup Handlos, Line; Fog Olwig, Karen; Bygbjerg, Ib Christian; Norredam, Marie

    2016-01-01

    Equal and universal access to healthcare services is a core priority for a just health system. A key societal determinant seen to create inequality in access to healthcare is corruption in the healthcare system. How return migrants’ access to healthcare is affected by corruption is largely unstudied, even though return migrants may be particularly vulnerable to problems related to corruption due to their period of absence from their country of origin. This article investigates how corruption ...

  2. Pharmacologic Prophylaxis of Portal Venous System Thrombosis after Splenectomy: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xingshun Qi

    2014-01-01

    Full Text Available Portal venous system thrombosis (PVST is a life-threatening complication of splenectomy. A meta-analysis was conducted to explore the role of pharmacologic prophylaxis of PVST after splenectomy. Overall, 359 papers were initially identified via the PubMed, EMBASE, and Cochrane Library databases. Eight of them were eligible. The incidence of PVST after splenectomy was significantly lower in patients who received the preventive measures than in those who did not (odds ratio [OR]: 0.33, 95% confidence interval [CI]: 0.22–0.47, P<0.00001. Subgroup analyses demonstrated that the significant difference remained in studies including patients with portal hypertension (n=6, but not in those including patients with hematological diseases (n=2; the significant difference remained in studies using any type of prophylactic drugs (anticoagulants [n=6], thrombolytics [n=1], and prostaglandin E1 [n=1]; the significant difference remained in nonrandomized studies (n=5, but not in randomized studies (n=3. The risk of bleeding was similar between the two groups (OR: 0.65, 95% CI: 0.10–4.04, P=0.64. In conclusion, pharmacologic prophylaxis might decrease the incidence of PVST after splenectomy in patients with portal hypertension and did not increase the risk of bleeding. However, the effect of pharmacologic prophylaxis of PVST in patients with hematological diseases remained questioned.

  3. Effective Prevention for Portal Venous System Thrombosis After Splenectomy: A Meta-Analysis.

    Science.gov (United States)

    Zhang, Xiao; Wang, Yadong; Yu, Miao; Huang, Jinzhao; Deng, Dongfeng; Xue, Huanzhou

    2017-03-01

    Portal venous system thrombosis (PVST) is a common and potentially life-threatening complication of splenectomy for portal hypertension due to cirrhosis. A meta-analysis was conducted to study the necessity of pharmacologic prophylaxis of PVST after splenectomy and how to select the feasible treatment method. Articles were searched through the PubMed, EMBASE, Cochrane Library databases, and CNKI. Overall, 404 articles were initially identified, and 11 of them were eligible. Among these selected articles, 7 articles were associated with the necessity of anticoagulation for prevention of PVST, while 5 were about the drug selection. We first demonstrated that the incidence of PVST after splenectomy was significantly lower in patients who received the preventive measures than in those who did not (odds ratio [OR]: 0.22, 95% confidence interval [CI]: 0.13-0.39, P splenectomy and devascularization. Preventative use of anticoagulant drugs might decrease the incidence of PVST after splenectomy in patients with portal hypertension, new anticoagulant drugs such as low-molecular-weight heparin should be used, and early or combination use of anticoagulation drugs might lead to lower PVST incidence for patients.

  4. Cement embolism into the venous system after pedicle screw fixation: case report, literature review, and prevention tips

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2013-09-01

    Full Text Available The strength of pedicle screws attachment to the vertebrae is an important factor affecting their motion resistance and long term performance. Low bone quality, e.g. in osteopenic patients, keeps the screw bone interface at risk for subsidence and dislocation. In such cases, bone cement could be used to augment pedicle screw fixation. But its use is not free of risk. Therefore, clinicians, especially spine surgeons, radiologists, and internists should become increasingly aware of cement migration and embolism as possible complications. Here, we present an instructive case of cement embolism into the venous system after augmented screw fixation with fortunately asymptomatic clinical course. In addition we discuss pathophysiology and prevention methods as well as therapeutic management of this potentially life-threatening complication in a comprehensive review of the literature. However, only a few case reports of cement embolism into the venous system were published after augmented screw fixation.

  5. Return on Investment Analysis of Information Warfare Systems

    National Research Council Canada - National Science Library

    Rios, Cesar G., Jr

    2005-01-01

    .... This research and case study demonstrate how the Knowledge Value Added (KVA) Methodology can be used to formulate a framework for extracting and analyzing performance parameters and measures of effectiveness for each system...

  6. A Comet Surface Sample Return System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase II investigation will focus on the development of spacecraft systems required to obtain a sample from the nucleus of a comet, hermetically seal...

  7. Gestational related changes in the deep venous system of the lower limb on light reflection rheography in pregnancy and the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Calderwood, C.J. [St John' s Hospital, Livingston and Simpson Centre for Reproductive Health, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom)], E-mail: catherine.calderwood@luht.scot.nhs.uk; Jamieson, R. [Princess Royal Maternity Unit, Glasgow Royal Infirmary, Glasgow (United Kingdom); Greer, I.A. [Hull York Medical School, University of York, York (United Kingdom)

    2007-12-15

    Objective: To assess whether light reflection rheography testing is affected by the changes that occur in the deep venous system of the lower limb in pregnancy and the puerperium. Methods: Twenty five women with a singleton pregnancy were recruited to undergo duplex Doppler ultrasound examinations of the common femoral vein to measure the vessel diameter and the blood flow velocity. Light reflection rheography testing was subsequently performed and the rate of venous emptying in the lower limb calculated. Serial measurements using both techniques were made at 15, 28, 36 weeks, and term gestation and at 2 days and 6 weeks postpartum. Results: Duplex Doppler ultrasound confirmed that there is progressive dilatation of the deep venous system in pregnancy, which reaches a maximum at term and reverses after delivery. There is an accompanying reduction in blood flow velocity, which reaches a nadir at term and increases after delivery. The rate of venous emptying as measured by light reflection rheography decreases with increasing gestation, but did not fall to a level consistent with venous occlusion by a deep venous thrombosis. Conclusions: Light reflection rheography has been shown to provide reliable results in pregnancy and the puerperium. Therefore, it is a potential tool for screening for deep venous thrombosis in this population.

  8. Medical management of venous ulcers.

    Science.gov (United States)

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Splenectomy Causes 10-Fold Increased Risk of Portal Venous System Thrombosis in Liver Cirrhosis Patients.

    Science.gov (United States)

    Qi, Xingshun; Han, Guohong; Ye, Chun; Zhang, Yongguo; Dai, Junna; Peng, Ying; Deng, Han; Li, Jing; Hou, Feifei; Ning, Zheng; Zhao, Jiancheng; Zhang, Xintong; Wang, Ran; Guo, Xiaozhong

    2016-07-19

    BACKGROUND Portal venous system thrombosis (PVST) is a life-threatening complication of liver cirrhosis. We conducted a retrospective study to comprehensively analyze the prevalence and risk factors of PVST in liver cirrhosis. MATERIAL AND METHODS All cirrhotic patients without malignancy admitted between June 2012 and December 2013 were eligible if they underwent contrast-enhanced CT or MRI scans. Independent predictors of PVST in liver cirrhosis were calculated in multivariate analyses. Subgroup analyses were performed according to the severity of PVST (any PVST, main portal vein [MPV] thrombosis >50%, and clinically significant PVST) and splenectomy. Odds ratios (ORs) and 95% confidence intervals (CIs) were reported. RESULTS Overall, 113 cirrhotic patients were enrolled. The prevalence of PVST was 16.8% (19/113). Splenectomy (any PVST: OR=11.494, 95%CI=2.152-61.395; MPV thrombosis >50%: OR=29.987, 95%CI=3.247-276.949; clinically significant PVST: OR=40.415, 95%CI=3.895-419.295) and higher hemoglobin (any PVST: OR=0.974, 95%CI=0.953-0.996; MPV thrombosis >50%: OR=0.936, 95%CI=0.895-0.980; clinically significant PVST: OR=0.935, 95%CI=0.891-0.982) were the independent predictors of PVST. The prevalence of PVST was 13.3% (14/105) after excluding splenectomy. Higher hemoglobin was the only independent predictor of MPV thrombosis >50% (OR=0.952, 95%CI=0.909-0.997). No independent predictors of any PVST or clinically significant PVST were identified in multivariate analyses. Additionally, PVST patients who underwent splenectomy had a significantly higher proportion of clinically significant PVST but lower MELD score than those who did not undergo splenectomy. In all analyses, the in-hospital mortality was not significantly different between cirrhotic patient with and without PVST. CONCLUSIONS Splenectomy may increase by at least 10-fold the risk of PVST in liver cirrhosis independent of severity of liver dysfunction.

  10. [Influence of the arterio-venous fistula on cardiovascular system in patients with particular cardiovascular risk].

    Science.gov (United States)

    Krajewska, Magdalena; Weyde, Wacław; Kosmala, Wojciech; Klinger, Marian

    2006-08-01

    In the population of hemodialysis patients the risk of ischemic heart disease and morbidity related to it, is considerably higher than in general population. In the group of elderly hemodialysed patients and in patients with diabetes this risk is even higher Additional risk factors of cardiovascular disease are those specific for renal insufficiency, including the presence of arterio-venous fistula, which is believed to be an independent risk factor for cardiovascular disease through the promotion of hyperkinetic circulation. In the study the impact of the arterio-venous fistula on heart function in Doppler USG in the group of 16 elderly hemodialysis patients (aged 79, 4 +/- 5,4), 10 diabetics with type 2 diabetes (aged 63,2 +/- 10,4) and 7 hemodialysis patients younger and without diabetes was examined. In all patients arterio-venous fistula was created on the forearm from native vessels. The following hemodynamic USG parameters of heart function were assessed: ejection fraction (EF), shortening fraction (FS), stroke volume (SV) and cardiac output (CO). We conclude that impact of native arterio-venous fistula created on forearm on circulation in the group of elderly and diabetic patients is of the same magnitude as in the group of younger, non diabetic patients.

  11. Postoperative Catheter-Directed Thrombolysis Versus Systemic Anticoagulation for Acute Superior Mesenteric Venous Thrombosis.

    Science.gov (United States)

    Yang, Shuofei; Zhang, Lan; Liu, Kai; Fan, Xinxin; Ding, Weiwei; He, Changsheng; Wu, Xingjiang; Li, Jieshou

    2016-08-01

    Little data evaluate catheter-directed thrombolysis (CDT) therapy as a sequential treatment of emergent surgery for patients with acute superior mesenteric venous thrombosis (ASMVT). We compared the outcomes of ASMVT patients receiving CDT via superior mesenteric artery (SMA) with those who had systemic anticoagulation after emergent laparotomy. A single-center retrospective study of ASMVT patients receiving emergent laparotomy from May 2012 to April 2014 was performed. Patients in group I had postoperative systemic anticoagulation and patients in group II underwent postoperative CDT. The demography, etiology, imaging features, clinical outcomes, and complications were compared. Moreover, univariate analysis was performed to identify confounding variables of 30-day mortality. Thirty-two patients (20 males, mean age of 44.9 ± 10.6 years) were included, 17 in group I and 15 in group II. No significant differences of demographic data, etiology, baseline value, and perioperative comorbidity were found. The rate of complete thrombus removal was significantly higher in group II than group I (29.4% vs. 80.0%, P = 0.001). The second-look laparotomy and repeat bowel resection (58.8% vs. 13.3%, P = 0.002) were required in fewer patients in group II (20.0% vs. 70.6%, P = 0.001). The incidence of short-bowel syndrome (SBS; 41.2% vs. 6.7%, P = 0.001) and 30-day mortality (41.2% vs. 6.7%, P = 0.001) were lower in group II. The 1-year survival was also better in group II (52.9% vs. 93.3%, P = 0.014). The incidence of massive abdominal hemorrhage requiring blood transfusion and surgical intervention was 11.8% in group I and 20.0% in group II (P = 0.645). The age, serum D-dimer level, SBS, and postoperative CDT were significant risk factors of 30-day mortality in this study. For ASMVT patients receiving emergent surgery and intraoperative thrombectomy, the algorithm with postoperative CDT via SMA is associated with more favorable clinical outcome compared with

  12. Return to work after renal transplantation: a study of the Brazilian Public Social Security System.

    Science.gov (United States)

    Messias, Alexandre Augusto; Reichelt, Angela J; Dos Santos, Edson F; Albuquerque, Galton C; Kramer, José S P; Hirakata, Vania N; Garcia, Valter D

    2014-12-15

    Return to work is an objective parameter used worldwide to evaluate the success of organ transplantation and is especially feasible after renal transplantation. This study sought to describe the frequency of return to work after renal transplantation and related characteristics. Retrospective cohort of 511 isolated kidney transplant recipients was recruited from a Brazilian referral center from January 2005 to December 2009; all were matched to the public social security database to determine inclusion and benefit awards, as well as the rate of resumption of contributions to the public social security system, a surrogate marker of work rehabilitation. Characteristics associated with work return were analyzed. No social security records were found for 28 subjects. The remaining 483 subjects had a mean age of 45±13 years; 62% were male; 401 (83%) received some public social security benefit; 298 were paying dues and could, therefore, receive temporary or permanent disability benefits. Of these, 78 subjects made social security payments after transplantation, resulting in a work return rate of 26% (95% confidence interval, 21-32). Younger age, living donor graft, and chronic glomerulonephritis were significantly associated with return to work. In Brazil, most renal transplant recipients are on social security benefits, but only a small proportion return to work after surgery. Clinical characteristics may help define work resumption trends.

  13. Imaging of cerebral venous complications in patients with infections

    Directory of Open Access Journals (Sweden)

    Xudong Shen

    2017-09-01

    Full Text Available Systemic and local infections can cause cerebrovascular complications in the central nervous system. The involvement of cerebral venous system would result in venous or dural venous sinus thrombophlebitis. Images can help evaluate the venous complications in patients with central nervous system infection and provide information in guiding treatment and prognosis. The main focus of this review is to emphasize the proper utilization of imaging modalities in assessment the complications of cerebral venous system in patients with infection.

  14. Neglected chaos in international stock markets: Bayesian analysis of the joint return-volatility dynamical system

    Science.gov (United States)

    Tsionas, Mike G.; Michaelides, Panayotis G.

    2017-09-01

    We use a novel Bayesian inference procedure for the Lyapunov exponent in the dynamical system of returns and their unobserved volatility. In the dynamical system, computation of largest Lyapunov exponent by traditional methods is impossible as the stochastic nature has to be taken explicitly into account due to unobserved volatility. We apply the new techniques to daily stock return data for a group of six countries, namely USA, UK, Switzerland, Netherlands, Germany and France, from 2003 to 2014, by means of Sequential Monte Carlo for Bayesian inference. The evidence points to the direction that there is indeed noisy chaos both before and after the recent financial crisis. However, when a much simpler model is examined where the interaction between returns and volatility is not taken into consideration jointly, the hypothesis of chaotic dynamics does not receive much support by the data ("neglected chaos").

  15. PredyCLU: a prediction system for chronic leg ulcers based on fuzzy logic; part I - exploring the venous side.

    Science.gov (United States)

    de Franciscis, Stefano; Fregola, Salvatore; Gallo, Alessandro; Argirò, Giuseppe; Barbetta, Andrea; Buffone, Gianluca; Caliò, Francesco G; De Caridi, Giovanni; Amato, Bruno; Serra, Raffaele

    2016-12-01

    Chronic leg ulcers (CLUs) are a common occurrence in the western population and are associated with a negative impact on the quality of life of patients. They also cause a substantial burden on the health budget. The pathogenesis of leg ulceration is quite heterogeneous, and chronic venous ulceration (CVU) is the most common manifestation representing the main complication of chronic venous disease (CVD). Prevention strategies and early identification of the risk represent the best form of management. Fuzzy logic is a flexible mathematical system that has proved to be a powerful tool for decision-making systems and pattern classification systems in medicine. In this study, we have elaborated a computerised prediction system for chronic leg ulcers (PredyCLU) based on fuzzy logic, which was retrospectively applied on a multicentre population of 77 patients with CVD. This evaluation system produced reliable risk score patterns and served effectively as a stratification risk tool in patients with CVD who were at the risk of developing CVUs. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  16. Return Migrants’ Experience of Access to Care in Corrupt Healthcare Systems: The Bosnian Example

    Science.gov (United States)

    Neerup Handlos, Line; Fog Olwig, Karen; Bygbjerg, Ib Christian; Norredam, Marie

    2016-01-01

    Equal and universal access to healthcare services is a core priority for a just health system. A key societal determinant seen to create inequality in access to healthcare is corruption in the healthcare system. How return migrants’ access to healthcare is affected by corruption is largely unstudied, even though return migrants may be particularly vulnerable to problems related to corruption due to their period of absence from their country of origin. This article investigates how corruption in the healthcare sector affects access to healthcare for refugees who repatriated to Bosnia, a country with a high level of corruption, from Denmark, a country with a low level of corruption. The study is based on 18 semi-structured interviews with 33 refugees who returned after long-term residence in Denmark. We found that the returned refugees faced greater problems with corruption than was the case for those who had not left the country, as doctors considered them to be better endowed financially and therefore demanded larger bribes from them than they did from those who had remained in Bosnia. Moreover, during their stay abroad the returnees had lost the connections that could have helped them sidestep the corruption. Returned refugees are thus particularly vulnerable to the effects of corruption. PMID:27657096

  17. Return Migrants' Experience of Access to Care in Corrupt Healthcare Systems: The Bosnian Example.

    Science.gov (United States)

    Neerup Handlos, Line; Fog Olwig, Karen; Bygbjerg, Ib Christian; Norredam, Marie

    2016-09-19

    Equal and universal access to healthcare services is a core priority for a just health system. A key societal determinant seen to create inequality in access to healthcare is corruption in the healthcare system. How return migrants' access to healthcare is affected by corruption is largely unstudied, even though return migrants may be particularly vulnerable to problems related to corruption due to their period of absence from their country of origin. This article investigates how corruption in the healthcare sector affects access to healthcare for refugees who repatriated to Bosnia, a country with a high level of corruption, from Denmark, a country with a low level of corruption. The study is based on 18 semi-structured interviews with 33 refugees who returned after long-term residence in Denmark. We found that the returned refugees faced greater problems with corruption than was the case for those who had not left the country, as doctors considered them to be better endowed financially and therefore demanded larger bribes from them than they did from those who had remained in Bosnia. Moreover, during their stay abroad the returnees had lost the connections that could have helped them sidestep the corruption. Returned refugees are thus particularly vulnerable to the effects of corruption.

  18. Return Migrants’ Experience of Access to Care in Corrupt Healthcare Systems: The Bosnian Example

    Directory of Open Access Journals (Sweden)

    Line Neerup Handlos

    2016-09-01

    Full Text Available Equal and universal access to healthcare services is a core priority for a just health system. A key societal determinant seen to create inequality in access to healthcare is corruption in the healthcare system. How return migrants’ access to healthcare is affected by corruption is largely unstudied, even though return migrants may be particularly vulnerable to problems related to corruption due to their period of absence from their country of origin. This article investigates how corruption in the healthcare sector affects access to healthcare for refugees who repatriated to Bosnia, a country with a high level of corruption, from Denmark, a country with a low level of corruption. The study is based on 18 semi-structured interviews with 33 refugees who returned after long-term residence in Denmark. We found that the returned refugees faced greater problems with corruption than was the case for those who had not left the country, as doctors considered them to be better endowed financially and therefore demanded larger bribes from them than they did from those who had remained in Bosnia. Moreover, during their stay abroad the returnees had lost the connections that could have helped them sidestep the corruption. Returned refugees are thus particularly vulnerable to the effects of corruption.

  19. A prospective case series evaluating the safety and efficacy of the Klox BioPhotonic System in venous leg ulcers

    Directory of Open Access Journals (Sweden)

    Nikolis A

    2016-09-01

    Full Text Available Andreas Nikolis,1 Doria Grimard,2 Yves Pesant,3 Giovanni Scapagnini,4 Denis Vézina5 1Division of Plastic Surgery, Victoria Park Research Centre, Montreal, 2Q&T Research Chicoutimi, Chicoutimi, 3St-Jerome Medical Research Inc., St-Jerome, Quebec, Canada; 4Department of Medicine and Health Sciences, School of Medicine, University of Molise, Campobasso, Italy; 5Klox Technologies, Laval, Quebec, Canada Purpose: To investigate the safety and efficacy of the BioPhotonic System developed by Klox Technologies in a case series of ten patients with venous leg ulcers.Patients and methods: Ten patients with chronic venous leg ulcers, having failed on at least one previous therapy, were enrolled into this case series.Results: Nine patients were evaluable for efficacy. A response (defined as decrease in wound surface area was observed in seven patients (77.8%. Of these, four patients (44.4% achieved wound closure on average 4 months (127.5 days following the beginning of the treatment. Two patients did not respond to the investigational treatment. Quality of life improved over time throughout the study. Compliance was excellent, with 93.2% of visits completed as per protocol. Safety was unremarkable, with only four treatment-emergent-related adverse events, for which no specific intervention was required.Conclusion: The BioPhotonic System was shown to be safe and extremely well tolerated. It also demonstrated potential in terms of wound closure, wound surface area decrease, and wound bed preparation. Keywords: biophotonics, light, photobiomodulation, venous leg ulcers

  20. School Personnel Perceptions of Youth with Disabilities Returning to High School from the Juvenile Justice System

    Science.gov (United States)

    Sinclair, James S.; Unruh, Deanne K.; Griller Clark, Heather; Waintrup, Miriam G.

    2017-01-01

    Little is known about the perceptions of teachers of their students returning from the juvenile justice system, which can influence student relationships and student engagement, both of which are critical to reduce recidivism rates. This study utilized an online survey to examine the perceptions of a convenience sample of 283 school personnel…

  1. The extracranial venous system in the heads of beaked whales, with implications on diving physiology and pathogenesis.

    Science.gov (United States)

    Costidis, Alexander M; Rommel, Sentiel A

    2016-01-01

    Beaked whales are a poorly known but diverse group of whales that have received considerable attention due to strandings that have been temporally and spatially associated with naval sonar deployment. Postmortem studies on stranded carcasses have revealed lesions consistent with decompression sickness, including intravascular gas and fat emboli. These findings have been supported by analyses of intravascular gas emboli showing composition dominated by nitrogen gas. To increase our understanding of the pathophysiology of nitrogen bubble formation and intravascular embolization, we examined the gross and microscopic anatomy of the venous system in the head of beaked whales. Since the potential sources of intravascular fat and gas emboli were of greatest interest, focus was placed on the acoustic fat bodies and pneumatic accessory sinus system. Herein, we describe intimate arteriovenous associations with specialized adipose depots and air sinuses in beaked whales. These vascular structures comprise an extensive network of thin-walled vessels with a large surface area, which is likely to facilitate exchange of nitrogen gas and may, therefore, form anatomic regions that may be important in physiological management of diving gases. These structures may also be vulnerable to pathologic introduction of emboli into the vascular system. Expansive, thin-walled venous lakes are found within the pterygoid region, which suggest the potential for nitrogen exchange as well as for compensation of middle-ear pressures during descent on a dive. These findings warrant further research into the structure and function of this morphology as it relates to normal and pathologic physiology. © 2015 Wiley Periodicals, Inc.

  2. Indivíduo do sexo masculino XYY com retorno venoso pulmonar anômalo total e baixa estatura XYY male with total anomalous pulmonary venous return and short stature

    Directory of Open Access Journals (Sweden)

    Hiroyuki Nagasawa

    2003-02-01

    Full Text Available Objetivo: relatar o caso de um neonato masculino 47 XYY com doença cardíaca congênita e baixa estatura. Resultados: este é o primeiro relato de caso de um neonato masculino 47 XYY, pequeno para a idade, com doença cardíaca congênita (retorno venoso pulmonar anômalo total. O neonato nasceu com 32 semanas de gestação e peso de 1.134 g. Uma hemorragia intracraniana e um alto fluxo pulmonar foram descobertos no período neonatal inicial. Havia grande retardo de desenvolvimento neuromotor. A criança recebeu uma ligadura paliativa do ductus arteriosus e a colocação de um shunt ventriculoperitoneal, mas morreu com 19 meses de vida de insuficiência cardíaca. Comentários: esta combinação de menino XYY e doença cardíaca congênita pode ser fortuita. Entretanto, pensamos que é importante relatar que houve este caso de prognóstico pobre de um indivíduo XYY do sexo masculino com doença cardíaca congênita e baixa estatura.Objective: to report a case of a 47 XYY male neonate with congenital heart disease and short stature. Description: this is the first case report of a 47 XYY male neonate associated with congenital heart disease (total anomalous pulmonary venous return and small for gestational age. The infant was born at around 32 weeks of gestation with 1,134g. Intracranial hemorrhage and pulmonary high flow were discovered in the early neonatal period. Retarded physical and mental development was observed. The infant underwent a palliative ligation of the ductus arteriosus and a ventriculoperitoneal shunt operation, but died due to consequent heart failure at 19 months of age. Comments: this combination of XYY male and congenital heart disease may be fortuitous. However, we think it is important to report that there was a poor prognosis case of XYY male with congenital heart disease and short stature.

  3. Research on operating characteristics of direct-return chilled water system controlled by variable temperature difference

    International Nuclear Information System (INIS)

    Liu, Xue-feng; Liu, Jin-ping; Lu, Ji-dong; Liu, Lei; Zou, Wei

    2012-01-01

    Terminal load distribution and pipe network structure are the key factors that affect the energy-saving potential of central air-conditioning chilled water systems, nonlinear thermodynamic performance of an air-conditioning system with large inertia will mainly exert influence on the stability and reliability of energy-saving operation control. Unreasonable variable flow control strategy can neither achieve an ideal energy-saving effect nor meet the air-conditioning comfortableness requirements. With a direct-return chilled water system as study object, this paper built a hydraulic calculation model of pipe network topology, bypass loop hydraulic calculation model, AHU thermodynamic model, and water pump variable frequency operation model. Operating frequency of a water pump for different flow ratio, pump power, temperature difference of pipe network supply and return water, pressure difference of pipe network supply and return water, bypass control valve characteristics, system adjustability coefficient, and pipe network resistance characteristics of a chilled water system are studied under the condition of given supply water temperature, and pipe network’s AHU node thermal and humid load. And energy consumption characteristics of constant temperature difference control and variable temperature difference control are also analyzed with comparison. The results can provide theoretical guidance for the stable and reliable energy-saving operation of a chilled water system. -- Highlights: ► AHU thermodynamic model has been built to solve the heat/humidity balance problem. ► Hydraulic calculation models of direct-return pipe network topology has been built. ► Bypass loop has been considered to the analysis for variable flow operation. ► The universal problems for variable flow operation have been analyzed theoretically. ► Energy-saving operation strategies have been researched.

  4. Energy analysis of batteries in photovoltaic systems. Part II: Energy return factors and overall battery efficiencies

    International Nuclear Information System (INIS)

    Rydh, Carl Johan; Sanden, Bjoern A.

    2005-01-01

    Energy return factors and overall energy efficiencies are calculated for a stand-alone photovoltaic (PV)-battery system. Eight battery technologies are evaluated: lithium-ion (nickel), sodium-sulphur, nickel-cadmium, nickel-metal hydride, lead-acid, vanadium-redox, zinc-bromine and polysulphide-bromide. With a battery energy storage capacity three times higher than the daily energy output, the energy return factor for the PV-battery system ranges from 2.2 to 10 in our reference case. For a PV-battery system with a service life of 30 yr, this corresponds to energy payback times between 2.5 and 13 yr. The energy payback time is 1.8-3.3 yr for the PV array and 0.72-10 yr for the battery, showing the energy related significance of batteries and the large variation between different technologies. In extreme cases, energy return factors below one occur, implying no net energy output. The overall battery efficiency, including not only direct energy losses during operation but also energy requirements for production and transport of the charger, the battery and the inverter, is 0.41-0.80. For some batteries, the overall battery efficiency is significantly lower than the direct efficiency of the charger, the battery and the inverter (0.50-0.85). The ranking order of batteries in terms of energy efficiency, the relative importance of different battery parameters and the optimal system design and operation (e.g. the use of air conditioning) are, in many cases, dependent on the characterisation of the energy background system and on which type of energy efficiency measure is used (energy return factor or overall battery efficiency)

  5. Provisional Matrix Deposition in Hemostasis and Venous Insufficiency: Tissue Preconditioning for Nonhealing Venous Ulcers

    Science.gov (United States)

    Parker, Tony J.; Broadbent, James A.; McGovern, Jacqui A.; Broszczak, Daniel A.; Parker, Christina N.; Upton, Zee

    2015-01-01

    Significance: Chronic wounds represent a major burden on global healthcare systems and reduce the quality of life of those affected. Significant advances have been made in our understanding of the biochemistry of wound healing progression. However, knowledge regarding the specific molecular processes influencing chronic wound formation and persistence remains limited. Recent Advances: Generally, healing of acute wounds begins with hemostasis and the deposition of a plasma-derived provisional matrix into the wound. The deposition of plasma matrix proteins is known to occur around the microvasculature of the lower limb as a result of venous insufficiency. This appears to alter limb cutaneous tissue physiology and consequently drives the tissue into a ‘preconditioned’ state that negatively influences the response to wounding. Critical Issues: Processes, such as oxygen and nutrient suppression, edema, inflammatory cell trapping/extravasation, diffuse inflammation, and tissue necrosis are thought to contribute to the advent of a chronic wound. Healing of the wound then becomes difficult in the context of an internally injured limb. Thus, interventions and therapies for promoting healing of the limb is a growing area of interest. For venous ulcers, treatment using compression bandaging encourages venous return and improves healing processes within the limb, critically however, once treatment concludes ulcers often reoccur. Future Directions: Improved understanding of the composition and role of pericapillary matrix deposits in facilitating internal limb injury and subsequent development of chronic wounds will be critical for informing and enhancing current best practice therapies and preventative action in the wound care field. PMID:25785239

  6. Calculating systems-scale energy efficiency and net energy returns: A bottom-up matrix-based approach

    International Nuclear Information System (INIS)

    Brandt, Adam R.; Dale, Michael; Barnhart, Charles J.

    2013-01-01

    In this paper we expand the work of Brandt and Dale (2011) on ERRs (energy return ratios) such as EROI (energy return on investment). This paper describes a “bottom-up” mathematical formulation which uses matrix-based computations adapted from the LCA (life cycle assessment) literature. The framework allows multiple energy pathways and flexible inclusion of non-energy sectors. This framework is then used to define a variety of ERRs that measure the amount of energy supplied by an energy extraction and processing pathway compared to the amount of energy consumed in producing the energy. ERRs that were previously defined in the literature are cast in our framework for calculation and comparison. For illustration, our framework is applied to include oil production and processing and generation of electricity from PV (photovoltaic) systems. Results show that ERR values will decline as system boundaries expand to include more processes. NERs (net energy return ratios) tend to be lower than GERs (gross energy return ratios). External energy return ratios (such as net external energy return, or NEER (net external energy ratio)) tend to be higher than their equivalent total energy return ratios. - Highlights: • An improved bottom-up mathematical method for computing net energy return metrics is developed. • Our methodology allows arbitrary numbers of interacting processes acting as an energy system. • Our methodology allows much more specific and rigorous definition of energy return ratios such as EROI or NER

  7. Modeling the return and volatility of the Greek electricity marginal system price

    International Nuclear Information System (INIS)

    Traditional cost based optimization models (WASP) for expansion planning do not allow for mark-to-market valuation and cannot satisfy arbitrage free requirements. This work will fill this gap by developing and estimating models for mark-to-market valuation. Furthermore the present paper examines the return and volatility of the newly born Greek's electricity market's marginal system price. A detailed description of the market mechanism and regulation is used to describe how prices are determined in order to proceed with return and volatility modeling. Continuous time mean reverting and time varying mean reverting stochastic processes have been solved in discrete time processes and estimated econometrically along with ARMAX and GARCH models. It was found that GARCH model gave much better estimation and forecasting ability. Strong persistence in mean has been found giving suspicions of market inefficiency and strong incentives for arbitrage opportunities. Finally, the change in the regulatory framework has been controlled and found to have significant impact

  8. Electronic trading system and returns volatility in the oil futures market

    International Nuclear Information System (INIS)

    Liao, Huei-Chu; Lee, Yi-Huey; Suen, Yu-Bo

    2008-01-01

    This paper uses daily Brent crude prices to investigate the employment of electronic trading on the returns conditional volatility in the oil futures market. After a suitable GARCH model is established, the conditional volatility series are found. The Bai and Perron model is then used to find two significant structural breaks for these conditional volatility series around two implementation dates of electronic trading. This result indicates that the change in the trading system has significant impacts on the returns volatility since our estimated second break date is very close to the all-electronic trade implementation date. Moreover, the conditional volatility in the all-electronic trading period is found to be more dominated by the temporal persistence rather than the volatility clustering effect. All these evidence can shed some light for explaining the high relationship between more volatile world oil price and the more popular electronic trade. (author)

  9. Are hepatic portal venous system components distributed equally to the liver? A MDCT study

    International Nuclear Information System (INIS)

    Incedayi, M.; Aribal, S.; Sivrioglu, A.; Sonmez, G.; Ozturk, E.; Yalcin, B.; Basekim, C.

    2012-01-01

    Full text: Objective: We aimed to evaluate the relationships between the splenic index, right and left hepatic lobe volumes, diameters of splenic vein (SV), superior mesenteric vein (SMV) and the portal vein (PV) by Multidetector Computerized Tomography (MDCT). We also investigated indirect signs of portal venous flow pattern using these parameters. Material and method: Following their contrast thoracoabdominal and abdominal 64-MDCT examinations, the images of 100 cases (61 males and 39 females) were evaluated retrospectively. The patients who were included in the study ranged from age 20 to 88 (mean age: 41,78). For each case, the splenic index, total hepatic volume, left and right hepatic volumes were calculated on the post-contrast portal venous phase (50th sec) images. Cases without any known liver and spleen diseases were included in the study. Spearman and Pearson's correlation tests were carried out with the purpose of determining the relationships between the variables. Results: A statistically significant relationship between the splenic index and left hepatic lobe volume and total volume was demonstrated (p=0.001). Positive correlations between the left hepatic lobe volume and splenic index (r=0.55) and between the right hepatic lobe volume and splenic index (r=0.32) were also exhibited. However, the correlation between the left hepatic lobe volume and the splenic index was relatively stronger compared to the correlation between the right hepatic lobe volume and the splenic index (r=0.55 versus r= 0.32). Between the diameter of the SMV and right hepatic lobe volume a statistically significant relation was demonstrated (p<0.0001), and according to Pearson's correlation analysis, a positive correlation of medium strength (r=0.36) was observed. Conclusion: In our study, the MDCT findings revealed statistically significant relations between the splenic index and the left lobe volume and between the diameter of the SMV and the right lobe volume. Information

  10. Venous chest anatomy: clinical implications

    International Nuclear Information System (INIS)

    Chasen, M.H.; Charnsangavej, C.

    1998-01-01

    This article provides a practical approach to the clinical implications and importance of understanding the collateral venous anatomy of the thorax. Routine radiography, conventional venography, computed tomography (CT), and magnetic resonance (MR) imaging studies provide correlative anatomic models for the demonstration of how interconnecting collateral vascular networks within the thorax maintain venous stability at all times. Five major systems comprise the collateral venous network of the thorax ( Fig. 1 ). These include the paravertebral, azygos-hemiazygos, internal mammary, lateral thoracic, and anterior jugular venous systems (AJVS). The five systems are presented in the following sequence: (a) a brief introduction to the importance of catheter position and malposition in understanding access to the thoracic venous system, (b) the anatomy of the azygos-hemiazygos systems and their relationship with the paravertebral plexus, (c) the importance of the AJVS, (d) 'loop' concepts interconnecting the internal mammary and azygos-hemiazygos systems by means of the lateral thoracic and intercostal veins, and (e) the interconnecting venous networks on the thoracic side of the thoracoabdominal junction. Certain aspects of the venous anatomy of the thorax will not be discussed in this chapter and include (a) the intra-abdominal anastomoses between the superior and inferior vena cavae (IVC) via the internal mammary, lateral thoracic, and azygos-hemiazygos systems (beyond the scope of this article), (b) potential collateral vessels involving vertebral, parascapular, thyroidal, thymic, and other smaller veins that might anastomose with the major systems, and (c) anatomic variants and pitfalls that may mimic pathologic conditions (space limitations). (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  11. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    Energy Technology Data Exchange (ETDEWEB)

    Sofue, Keitaro, E-mail: ksofue@ncc.go.jp [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Department of Radiology, Kobe University, Graduate School of Medicine (Japan); Arai, Yasuaki; Takeuchi, Yoshito [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University, Graduate School of Medicine (Japan)

    2013-11-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required.

  12. Systematic review of topic treatment for venous ulcers

    OpenAIRE

    Borges, Eline Lima; Caliri, Maria Helena Larcher; Haas, Vanderlei José

    2007-01-01

    Venous ulcer patients can experience this situation for several years without achieving healing if treatment is inadequate. Evidence-based professional practice generates effective results for patients and services. This research aimed to carry out a systematic review to assess the most effective method to improve venous return and the best topic treatment for these ulcers. Studies were collected in eight databases, using the following descriptors: leg ulcer, venous ulcer and similar terms. T...

  13. The risk of pulmonary embolism and deep venous thrombosis in systemic lupus erythematosus: A general population-based study.

    Science.gov (United States)

    Aviña-Zubieta, J Antonio; Vostretsova, Kateryna; De Vera, Mary A; Sayre, Eric C; Choi, Hyon K

    2015-10-01

    To estimate the future risk and time trends of newly diagnosed venous thromboembolism (VTE) in individuals with incident systemic lupus erythematosus (SLE) in the general population. Using a population-based database that includes all residents of British Columbia, Canada we conducted a study cohort of all patients with incident SLE and up to 10 age-, sex-, and entry-time-matched individuals from the general population. We compared incidence rates of pulmonary embolism (PE), deep venous thrombosis (DVT), and VTE between the two groups according to SLE disease duration. We calculated hazards ratios (HR), adjusting for confounders. Among 4863 individuals with SLE (86% female; mean age, 48.9 years), the incidence rates (IRs) of PE, DVT, and VTE were 2.58, 3.33, and 5.32 per 1000 person-years, respectively, whereas the corresponding rates in the comparison cohort were 0.67, 0.57, and 1.11 per 1000 person-years. Compared with non-SLE individuals, the multivariable HRs among SLE patients were 3.04 (95% CI: 2.08-4.45), 4.46 (95% CI: 3.11-6.41), and 3.55 (95% CI: 2.69-4.69), respectively. The age-, sex-, and entry-time-matched HRs for PE, DVT, and VTE were highest during the first year after SLE diagnosis [13.57 (95% CI: 7.66-24.02), 11.13 (95% CI: 6.55-18.90), and 12.89 (95% CI: 8.56-19.41), respectively]. These findings provide population-based evidence that patients with SLE have a substantially increased risk of VTE, especially in the first year after SLE diagnosis. Awareness and increased vigilance of this potentially fatal, but preventable, complication is recommended. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. A Stakeholder-Based System Dynamics Model of Return-to-Work: A Research Protocol.

    Science.gov (United States)

    Jetha, Arif; Pransky, Glenn; Fish, Jon; Jeffries, Susan; Hettinger, Lawrence J

    2015-07-16

    Returning to work following a job-related injury or illness can be a complex process, influenced by a range of interrelated personal, psychosocial, and organizational components. System dynamics modelling (SDM) takes a sociotechnical systems perspective to view return-to-work (RTW) as a system made up of multiple feedback relationships between influential components. To build the RTW SDM, a mixed-method approach will be used. The first stage, that has already been completed, involved creating a baseline model using key informant interviews. Second, in two manufacturing companies, stakeholder-based models will be developed through interviews and focus groups with senior management, frontline workers, and frontline supervisors. Participants will be asked about the RTW process in general and more targeted questions regarding influential components. Participants will also be led through a reference mode exercise where they will be asked to estimate the direction, shape and magnitude of relationships between influential components. Data will be entered into the software program Vensim that provides a platform for visualizing system-structure and simulating the effects of adapting components. Finally, preliminary model validity testing will be conducted to provide insights on model generalizability and sensitivity. The proposed methodology will create a SDM of the RTW process using feedback relationships of influential components. It will also provide an important simulation tool to understand system behaviour that underlies complex RTW cases, and examine anticipated and unanticipated consequences of disability management policies. Significance for public healthWhile the incidence of occupational injuries and illnesses has declined over the past two decades, the proportion resulting in sickness absence has actually increased. Implementing strategies to address sickness absences and promote return-to-work (RTW) can significantly benefit physical and mental health, and

  15. A Sample Handling System for Mars Sample Return - Design and Status

    Science.gov (United States)

    Allouis, E.; Renouf, I.; Deridder, M.; Vrancken, D.; Gelmi, R.; Re, E.

    2009-04-01

    A mission to return atmosphere and soil samples form the Mars is highly desired by planetary scientists from around the world and space agencies are starting preparation for the launch of a sample return mission in the 2020 timeframe. Such a mission would return approximately 500 grams of atmosphere, rock and soil samples to Earth by 2025. Development of a wide range of new technology will be critical to the successful implementation of such a challenging mission. Technical developments required to realise the mission include guided atmospheric entry, soft landing, sample handling robotics, biological sealing, Mars atmospheric ascent sample rendezvous & capture and Earth return. The European Space Agency has been performing system definition studies along with numerous technology development studies under the framework of the Aurora programme. Within the scope of these activities Astrium has been responsible for defining an overall sample handling architecture in collaboration with European partners (sample acquisition and sample capture, Galileo Avionica; sample containment and automated bio-sealing, Verhaert). Our work has focused on the definition and development of the robotic systems required to move the sample through the transfer chain. This paper presents the Astrium team's high level design for the surface transfer system and the orbiter transfer system. The surface transfer system is envisaged to use two robotic arms of different sizes to allow flexible operations and to enable sample transfer over relatively large distances (~2 to 3 metres): The first to deploy/retract the Drill Assembly used for sample collection, the second for the transfer of the Sample Container (the vessel containing all the collected samples) from the Drill Assembly to the Mars Ascent Vehicle (MAV). The sample transfer actuator also features a complex end-effector for handling the Sample Container. The orbiter transfer system will transfer the Sample Container from the capture

  16. Non-invasive evaluation of the coronary venous system in patients with chronic systolic heart failure by 64-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cubuk, Rahmi; Tasali, Nuri; Celik, Levent; Guney, Sefik (Dept. of Radiology, Maltepe Univ. School of Medicine, Istanbul (Turkey)), email: rahmicubuk@yahoo.com; Aydin, Alper; Yilmazer, Serdar; Dagdeviren, Bahadir (Dept. of Cardiology, Maltepe Univ. School of Medicine, Istanbul (Turkey))

    2011-05-15

    Background: Imaging coronary venous systems to guide transcatheter cardiac interventions are becoming increasingly important, particularly in heart failure patients who are selected for cardiac resynchronization therapy (CRT). Failure of left ventricular (LV) lead placement during the procedure has been attributed to the inability to insert catheters into the coronary sinus and the lack of suitable side branches. Purpose To comparatively assess the value of a 64-detector MDCT examination in visualizing the cardiac veins and evaluating the morphological characteristics of the coronary venous system in patients with and without chronic systolic heart failure (SHF). Material and Methods A 64-detector MDCT examination of the heart was performed in 26 consecutive patients (five women, 21 men; mean age 57.80 +- 12.05 years; range 27-81 years) with chronic SHF. The morphological characteristics of the coronary venous system, such as the diameter, the distances between the venous tributaries, the angle and the tortuosity, were evaluated. The group was compared with a subgroup of 52 subjects without SHF (LV ejection fraction >40%) matched for age, sex, and the risk factors for coronary artery disease. Results: The coronary sinus (CS), great cardiac vein (GCV), anterior interventricular vein (AIV), and posterior interventricular vein (PIV) were visualized in all 78 individuals. The posterior vein of the left ventricle (PVLV) (63/78), left marginal vein (LMV) (72/78), and the small cardiac vein (SCV) (50/78) were visualized in SHF and control patients (p = NS). The lengths between venous tributaries were higher (p > 0.05) and more dilated (P < 0.001 for CS, GCV, AIV, PVLV, LMV; p = 0.001 for PIV) in the cases with SHF compared with the control population. The angle between the CS-GCV axis and the venous branches was wider (p = 0.02 for LMV and PIV, p = 0.001 for PVLV) and did not have any correlation with the LV diameter in cases with SHF. There was no difference between the

  17. Trade Study of Five In-Situ Propellant Production System for a Mars Sample Return Mission

    Science.gov (United States)

    Green, S. T.; Deffenbaugh, D. M.; Miller, M. A.

    1999-01-01

    One of the goals of NASA''s HEDS enterprise is to establish a long-term human presence on Mars at a fraction of the cost of employing today''s technology. The most direct method of reducing mission cost is to reduce the launch mass of the spacecraft. If the propellants for the return phase of the mission are produced on Mars, the total spacecraft mass could be reduced significantly. An interim goal is a Mars Sample Return (MSR) mission, which is proposed to demonstrate the feasibility of in-situ propellant production (ISPP). Five candidate ISPP systems for producing two fuels and oxygen from the Martian atmosphere are considered in this design trade-off study:(1) Zirconia cell with methanol synthesis, (2) Reverse water gas shift (RWGS) with water electrolysis and methanol synthesis, (3) Sabatier process for methane production with water electrolysis, (4) Sabatier process with water electrolysis and partial methane pyrolysis, and (5) Sabatier/RWGS combination with water electrolysis. These systems have been the subject of numerous previous analytical studies and laboratory demonstrations. In this investigation, the systems are objectively compared on the basis of thermochemical performance models using a commonly used chemical plant analysis software package. The realistic effects of incomplete chemical conversion and gas phase separator performance are included in these models. This study focuses on the chemical processing and product separation subsystems. The CO2 compression upstream of the chemical plane and the liquefaction/storage components are not included here.

  18. Venous leg ulcers.

    Science.gov (United States)

    Nelson, E Andrea

    2011-12-21

    Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2011 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). We found 101 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide

  19. Economic analysis of solar industrial process heat systems: A methodology to determine annual required revenue and internal rate of return

    Science.gov (United States)

    Dickinson, W. C.; Brown, K. C.

    1981-08-01

    An economic evaluation of solar industrial process heat systems, is developed to determine the annual required revenue and the internal rate of return. First, a format is provided to estimate the solar system's installed cost, annual operating and maintenance expenses, and net annual solar energy delivered to the industrial process. The annual required revenue and the price of solar is calculated. The economic attractiveness of the potential solar investment can be determined by comparing the price of solar energy with the price of fossilfuel, both expressed in levelized terms. This requires calcuation of the internal rate of return on the solar investment or, in certain cases, the growth rate of return.

  20. Energy Returned On Investment of Engineered Geothermal Systems Annual Report FY2011

    Energy Technology Data Exchange (ETDEWEB)

    Mansure, A.J.

    2011-12-31

    Energy Return On Investment (EROI) is an important figure of merit for assessing the viability of energy alternatives. For geothermal electric power generation, EROI is determined by the electricity delivered to the consumer compared to the energy consumed to construct, operate, and decommission the facility. Critical factors in determining the EROI of Engineered Geothermal Systems (EGS) are examined in this work. These include the input energy embodied into the system. The embodied energy includes the energy contained in the materials, as well as, that consumed in each stage of manufacturing from mining the raw materials to assembling the finished plant. Also critical are the system boundaries and value of the energy - heat is not as valuable as electrical energy.

  1. Representing distributed cognition in complex systems: how a submarine returns to periscope depth.

    Science.gov (United States)

    Stanton, Neville A

    2014-01-01

    This paper presents the Event Analysis of Systemic Teamwork (EAST) method as a means of modelling distributed cognition in systems. The method comprises three network models (i.e. task, social and information) and their combination. This method was applied to the interactions between the sound room and control room in a submarine, following the activities of returning the submarine to periscope depth. This paper demonstrates three main developments in EAST. First, building the network models directly, without reference to the intervening methods. Second, the application of analysis metrics to all three networks. Third, the combination of the aforementioned networks in different ways to gain a broader understanding of the distributed cognition. Analyses have shown that EAST can be used to gain both qualitative and quantitative insights into distributed cognition. Future research should focus on the analyses of network resilience and modelling alternative versions of a system.

  2. Prevalence and correlates of central venous catheter use among haemodialysis patients in the Irish health system - a national study.

    Science.gov (United States)

    Hussein, Wael F; Mohammed, Husham; Browne, Leonard; Plant, Liam; Stack, Austin G

    2018-04-02

    Central venous catheters (CVC) are associated with substantial morbidity and mortality among patients undergoing haemodialysis (HD), yet they are frequently used as the primary vascular access for many patients on HD. The goal of this study was to determine the prevalence and variation in CVC use across centres in the Irish health system. Data from the National Kidney Disease Clinical Patient Management System (KDCPMS) was used to determine CVC use and patterns across centres. Data on demographic characteristics, primary cause of end-stage kidney disease (ESKD), comorbid conditions, laboratory values and centre affiliation were extracted for adult HD patients (n = 1, 196) who were on dialysis for at least three months up to end of December 2016. Correlates of CVC use were explored using multivariable logistic regression. Overall prevalence of CVC use was 54% and varied significantly across clinical sites from 43% to 73%, P catheter use was greater for women than men, OR 1.77 (1.34-2.34) and for 2 out of 10 regional dialysis centres, OR 1.98 (1.02-3.84) and OR 2.86 (1.67-4.90) respectively compared to referent group). Catheters are the predominant type of vascular access in patients undergoing HD in the Irish health system. Substantial centre variation exists which is not explained by patient-level characteristics.

  3. Development and investigation of the accepting system for solidified bodies returned from foreign countries after reprocessing

    International Nuclear Information System (INIS)

    Sato, Hiroshi

    1981-01-01

    The Ministry of International Trade and Industry is to carry out from 1981 the development and investigation of the accepting system for high level radioactive wastes returned from foreign countries accompanying the execution of reprocessing contract. In Japan, all spent fuel from nuclear power stations is to be reprocessed to recover uranium and plutonium and to control radioactive wastes safely and in compact form. Until a new commercial reprocessing plant will be in operation around 1990, reprocessing is made by the commission contract with Great Britain and France. The presentation of the specifications of glass solidification of wastes will be made by the reprocessing contractors by January, 1982, and the power companies in Japan must reply on the possibility of acceptance within two years. The high level radioactive wastes arising from reprocessing are stored in tanks for several years to decay and cool, and thereafter, solidified with glass in canisters. The Power Reactor and Nuclear Fuel Development Corp. is forwarding the design and construction of a pilot plant for solidifying and storing high level radioactive wastes, the operation of which is scheduled in 1987. The development and investigation of the accepting system for returned solidified bodies are outlined. (Kako, I.)

  4. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  5. Editorial Comment on the articles of W. Mądry and M.A. Karolczak Totally anomalous pulmonary venous drainage – supracardiac type: ultrasound assessment of anatomically determined stenosis of the vertical vein collecting pulmonary venous return and Ultrasound diagnosis of pulmonary sling with proximal stenosis of left pulmonary artery and patent arterial duct

    Directory of Open Access Journals (Sweden)

    Maria Respondek‑Liberska

    2013-06-01

    Full Text Available Totally anomalous pulmonary venous drainage was for the first time described on the basis of a post-mortem examination in 1798(1. In the 21st century such pathologies are diagnosed in a living patient.

  6. Contemporary diagnosis of venous malformation

    Directory of Open Access Journals (Sweden)

    Lee BB

    2013-11-01

    Full Text Available BB Lee,1 I Baumgartner21Department of Surgery, George Washington University, Washington, DC, USA; 2Swiss Cardiovascular Center, University Hospital Bern, Bern, SwitzerlandAbstract: Venous malformation is a congenital vascular malformation resulting from defective development during various stages of embryogenesis and selectively affecting the venous system. Depending on the embryologic stage when the developmental arrest occurred, the clinical presentation of venous malformation is extremely variable in location, extent, severity, natural progression, and hemodynamic impact. Extratruncular lesions occur in the earlier stages of embryonic life, and retain characteristics unique to mesenchymal cells (angioblasts, growing and proliferating when stimulated internally (eg, by menarche, pregnancy, and hormones or externally (eg, by trauma or surgery. These lesions also have a significant hemodynamic impact on the venous system involved, in addition to the risk of localized intravascular coagulopathy. However, truncal lesions, as defective developments along the late stage, no longer carry the risk of proliferation and recurrence due to lack of mesenchymal characteristics. Although, they often have serious hemodynamic consequences due to direct involvement of the main vein trunk. Therefore, a thorough clinical history and careful physical examination should be followed by an appropriate combination of noninvasive and less invasive tests (eg, Doppler ultrasonography, magnetic resonance imaging, computed tomography to confirm the clinical impression as well as to define the extent and severity of the venous malformation. Invasive tests, eg, phlebography or angiography, are seldom needed for the diagnosis per se. Additional evaluation for coagulation abnormalities, eg, D-dimer and fibrinogen levels, is generally recommended, especially for the treatment of surgery and endovascular candidates with extensive lesions to assess the localized intravascular

  7. A Case of Systemic Lupus Erythematosus Presenting with the Clinical Picture of Recurrent Cerebral Venous Thrombosis and Devic-Like Syndrome

    Directory of Open Access Journals (Sweden)

    Şule Bilen

    2011-12-01

    Full Text Available Systemic lupus erythematosus(SLE which is generally related to central or peripheral nervous system abnormality is a complex and multisystem involving disease. Neurological involvement in SLE is known as bad prognostic criteria and considered as the major cause of mortality. 27 year old female patient was admitted to our clinic with the clinical pictures of recurrent cerebral venous thrombosis and myelitis accompanying to optic nerve involvement. While she has been evaluated for the etiology she was diagnosed as systemic lupus erythematosus because of establishment of the antibodies ANA ve Anti SS-A. Her response to endoxan and steroid treatment was good.In this paper we aimed to emphasize the significances of consideration of the diagnosis of SLE and immediate and appropriate immunosupressive treatment in patients applying in the clinical pictures of cerebral venous thrombosis and myelitis with optic nerve involvement eventhough they do not have the cardinal symptoms of the disease

  8. A country of emigration, immigration, transit and return? The formation of a Colombian migration system

    Directory of Open Access Journals (Sweden)

    Mauricio Palma

    2015-06-01

    Full Text Available Starting from the theory on Migration Systems advanced by Oliver Bakewell (2010, 2013, this article argues for the existence of a Colombian Migration System. It is the result of the historical existence of three elements: (a flows - of people, ideas and goods; (b institutions - in the sense of discourses and associated practices; and (c strategies, which respond to normative dynamics, as well as those derived from the environment in which the current migration wave has emerged. Its formation is the result of the interaction between economic and political determinants as well as cultural practices, in the transition of Colombia from a net emigration society into an immigration, transit, and return country.

  9. Mesenteric venous thrombosis

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001157.htm Mesenteric venous thrombosis To use the sharing features on this page, please enable JavaScript. Mesenteric venous thrombosis (MVT) is a blood clot in one or ...

  10. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  11. Fluidics comparison between dual pneumatic and spring return high-speed vitrectomy systems.

    Science.gov (United States)

    Brant Fernandes, Rodrigo A; Diniz, Bruno; Falabella, Paulo; Ribeiro, Ramiro; Teixeira, Anderson G; Magalhães, Octaviano; Moraes, Nilva; Maia, Andre; Farah, Michel E; Maia, Mauricio; Humayun, Mark S

    2015-01-01

    To compare the water and vitreous flow rates and duty cycle (DC) between two ultrahigh-speed vitrectomy systems: pneumatic with spring return (SR) and dual pneumatic (DP) probes. The flow rate was calculated using a high-sampling precision balance that measured the mass of water and vitreous removed from a vial by a vitreous cutter. Frame-by-frame analysis of a high-speed video of the cutter was used to determine the DC. Three cutters of each gauge (20, 23, and 25 G) were tested with an SR and a DP system using the standard DC setting (biased open) at 0 (water only), 1,000, 2,000, 3,000, 4,000, and 5,000 cuts per minute (CPM) with aspiration levels of 100, 200, 300, 400, 500, and 600 mm Hg. The DC was slightly higher with the SR system using most parameters and gauges although without statistical significance. The water flow rate was somewhat higher with the SR system, except for 25 G with 4,000 and 5,000 CPM. The vitreous flow rate was similar using most parameters, with the SR system showing higher flows at lower cut rates (1,000-3,000 CPM). SR and DP systems produced similar water and vitreous flow rates. Additional studies in human eyes are necessary to confirm these findings. Copyright 2015, SLACK Incorporated.

  12. Clinical application of three-dimensional printing to the management of complex univentricular hearts with abnormal systemic or pulmonary venous drainage.

    Science.gov (United States)

    McGovern, Eimear; Kelleher, Eoin; Snow, Aisling; Walsh, Kevin; Gadallah, Bassem; Kutty, Shelby; Redmond, John M; McMahon, Colin J

    2017-09-01

    In recent years, three-dimensional printing has demonstrated reliable reproducibility of several organs including hearts with complex congenital cardiac anomalies. This represents the next step in advanced image processing and can be used to plan surgical repair. In this study, we describe three children with complex univentricular hearts and abnormal systemic or pulmonary venous drainage, in whom three-dimensional printed models based on CT data assisted with preoperative planning. For two children, after group discussion and examination of the models, a decision was made not to proceed with surgery. We extend the current clinical experience with three-dimensional printed modelling and discuss the benefits of such models in the setting of managing complex surgical problems in children with univentricular circulation and abnormal systemic or pulmonary venous drainage.

  13. Venous Thromboembolic Events After Cerebral Vein Thrombosis

    NARCIS (Netherlands)

    Miranda, Bruno; Ferro, José M.; Canhão, Patrícia; Stam, Jan; Bousser, Marie-Germaine; Barinagarrementeria, Fernando; Scoditti, Umberto

    2010-01-01

    Background and Purpose-After cerebral vein and dural sinus thrombosis (CVT), there is an increased risk of further venous thromboembolic events (VTEs). Time to a second cerebral or systemic venous thrombotic event and risk factors for recurrence have not been investigated in large prospective

  14. A BMPy Road for Venous Development.

    Science.gov (United States)

    Goddard, Lauren M; Kahn, Mark L

    2017-09-11

    Detailed molecular pathways for the specific growth of arteries and lymphatic vessels have been identified, but the mechanisms controlling venous vessel growth have been obscure. Tischfield and colleagues (2017) shed new light on this problem by identifying a role for BMP signaling in development of the cerebral venous system. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Lithium Hideout and Return in the CANDU Heat Transport System during Shutdown and Start-up

    International Nuclear Information System (INIS)

    Qiu, L.; Snaglewski, A.P.

    2012-09-01

    Lithium hydroxide is used to control the pH a (pH apparent) of the Heat Transport System (HTS) coolant in CANDU R reactors. The recommended range of the lithium concentration in the coolant is between 0.38 ppm (5.5x10 -5 m) and 0.60 ppm (8.7x10 -5 m) to minimize carbon steel corrosion in the HTS and magnetite deposition in the core during normal operation; this corresponds to pH a values between 10.2 and 10.4. Similar pH a and lithium concentrations should be maintained during shutdown and start-up. However, maintaining the pH a of the HTS coolant within specification during shutdown and start-up has been difficult for some CANDU stations, especially when the HTS is taken to a Low Level Drain State (LLDS), because of lithium hideout and return. This paper presents the results from lithium adsorption and desorption studies on iron oxides under relevant shutdown and start-up chemistry conditions performed to elucidate the mechanisms of the observed lithium hideout and return. The results show that lithium hideout and return are driven largely by changes in the solubility of magnetite as the HTS coolant chemistry changes during shutdown; changes in lithium concentration were inversely correlated with the solubility of magnetite. When the HTS system is de-pressurized and drained to a low coolant level, the ingress of air rapidly oxidizes the dissolved Fe (II) in the coolant, 2Fe +2 + 1 / 2 O 2 + 3 H 2 = 2FEOOH + 4 H + , resulting in the formation of lepidocrocite or maghemite, which have much lower solubilities but larger surface areas than does magnetite. The large surface area of the Fe (III) oxides can adsorb significant quantities of lithium from the coolant, leading to lithium hideout and a pH a decrease. During start-up, the chemistry of the coolant changes from oxidizing to reducing, and lepidocrocite and other Fe (III) oxides are reduced to Fe (II), gradually dissolving as their solubility increases with increasing temperature. The adsorbed lithium is released

  16. Touch And Go Camera System (TAGCAMS) for the OSIRIS-REx Asteroid Sample Return Mission

    Science.gov (United States)

    Bos, B. J.; Ravine, M. A.; Caplinger, M.; Schaffner, J. A.; Ladewig, J. V.; Olds, R. D.; Norman, C. D.; Huish, D.; Hughes, M.; Anderson, S. K.; Lorenz, D. A.; May, A.; Jackman, C. D.; Nelson, D.; Moreau, M.; Kubitschek, D.; Getzandanner, K.; Gordon, K. E.; Eberhardt, A.; Lauretta, D. S.

    2018-02-01

    NASA's OSIRIS-REx asteroid sample return mission spacecraft includes the Touch And Go Camera System (TAGCAMS) three camera-head instrument. The purpose of TAGCAMS is to provide imagery during the mission to facilitate navigation to the target asteroid, confirm acquisition of the asteroid sample, and document asteroid sample stowage. The cameras were designed and constructed by Malin Space Science Systems (MSSS) based on requirements developed by Lockheed Martin and NASA. All three of the cameras are mounted to the spacecraft nadir deck and provide images in the visible part of the spectrum, 400-700 nm. Two of the TAGCAMS cameras, NavCam 1 and NavCam 2, serve as fully redundant navigation cameras to support optical navigation and natural feature tracking. Their boresights are aligned in the nadir direction with small angular offsets for operational convenience. The third TAGCAMS camera, StowCam, provides imagery to assist with and confirm proper stowage of the asteroid sample. Its boresight is pointed at the OSIRIS-REx sample return capsule located on the spacecraft deck. All three cameras have at their heart a 2592 × 1944 pixel complementary metal oxide semiconductor (CMOS) detector array that provides up to 12-bit pixel depth. All cameras also share the same lens design and a camera field of view of roughly 44° × 32° with a pixel scale of 0.28 mrad/pixel. The StowCam lens is focused to image features on the spacecraft deck, while both NavCam lens focus positions are optimized for imaging at infinity. A brief description of the TAGCAMS instrument and how it is used to support critical OSIRIS-REx operations is provided.

  17. An ultrasound study of gestational and postural changes in the deep venous system of the leg in pregnancy.

    Science.gov (United States)

    Macklon, N S; Greer, I A; Bowman, A W

    1997-02-01

    To investigate gestational and postural changes in diameter and blood flow in the proximal deep leg veins during pregnancy. A longitudinal, prospective observational study. The ultrasound department of a teaching maternity hospital. Twenty-four healthy women with uncomplicated singleton pregnancies. Real-time and duplex Doppler ultrasound assessments of the vessel diameter, flow velocity and respiratory flow fluctuation in the proximal deep leg veins of women serially measured from the first trimester of pregnancy to six weeks postnatally. The effects of increasing gestation and the adoption of the left lateral position on the above parameters. An increase in vessel diameter and a fall in flow velocity with increasing gestation was observed. However, no change in venous flow variation was observed. Delivery had reverse effects. Flow velocity was slower in the left than right legs, but on adoption of the left lateral position an increase in flow velocity and venous flow variation was observed in both legs during pregnancy. These data are consistent with the observed increase in incidence and pattern of deep venous thrombosis in pregnancy and may aid interpretation of duplex Doppler ultrasound examinations for deep venous thrombosis in pregnancy. Postural changes should be part of this evaluation. The gravid uterus may not be the sole cause for postural changes in deep venous flow velocity.

  18. Distribution of return point memory states for systems with stochastic inputs

    International Nuclear Information System (INIS)

    Amann, A; Brokate, M; Rachinskii, D; Temnov, G

    2011-01-01

    We consider the long term effect of stochastic inputs on the state of an open loop system which exhibits the so-called return point memory. An example of such a system is the Preisach model; more generally, systems with the Preisach type input-state relationship, such as in spin-interaction models, are considered. We focus on the characterisation of the expected memory configuration after the system has been effected by the input for sufficiently long period of time. In the case where the input is given by a discrete time random walk process, or the Wiener process, simple closed form expressions for the probability density of the vector of the main input extrema recorded by the memory state, and scaling laws for the dimension of this vector, are derived. If the input is given by a general continuous Markov process, we show that the distribution of previous memory elements can be obtained from a Markov chain scheme which is derived from the solution of an associated one-dimensional escape type problem. Formulas for transition probabilities defining this Markov chain scheme are presented. Moreover, explicit formulas for the conditional probability densities of previous main extrema are obtained for the Ornstein-Uhlenbeck input process. The analytical results are confirmed by numerical experiments.

  19. Early Warning System in ASEAN Countries Using Capital Market Index Return: Modiied Markov Regime Switching Model

    Directory of Open Access Journals (Sweden)

    Imam Wahyudi

    2014-08-01

    Full Text Available Asia's  inancial  crisis  in  July  1997  affects  currency,  capital  market,  and  real  market throughout  Asian  countries.  Countries  in  southeast  region  (ASEAN,  including  Indonesia, Malaysia, Philippines, Singapore, and Thailand, are some of the countries where the crisis hit  the  most.  In  these  countries,  where  inancial  sectors  are  far  more  developed  than  real sectors  and  the  money  market  sectors,  most  of  the  economic  activities  are  conducted  in capital  market.  Movement  in  the  capital  market  could  be  a  proxy  to  describe  the  overall economic  situation  and  therefore  the  prediction  of  it  could  be  an  early  warning  system  of economic crises. This paper tries to investigate movement in ASEAN (Indonesia, Malaysia, Philippines,  Singapore,  and  Thailand  capital  market  to  build  an  early  warning  system from inancial sectors perspective. This paper will be very beneicial for the government to anticipate the forthcoming crisis. The insight of this paper is from Hamilton (1990 model of regime switching process in which he divide the movement of currency into two regimes, describe the switching transition based on Markov process and creates different model for each regimes. Differ from Hamilton, our research focuses on index return instead of currency to  model  the  regime  switching.  This  research  aimed  to  ind  the  probability  of  crisis  in  the future by combining the probability of switching and the probability distribution function of each  regime.  Probability  of  switching  is  estimated  by  categorizing  the  movement  in  index return  into  two  regimes  (negative  return  in  regime  1  and  positive  return  in  regime  2  then measuring  the  proportion  of  switching  to  regime  1  in  t  given  regime

  20. Return-to-Work Within a Complex and Dynamic Organizational Work Disability System.

    Science.gov (United States)

    Jetha, Arif; Pransky, Glenn; Fish, Jon; Hettinger, Lawrence J

    2016-09-01

    Background Return-to-work (RTW) within a complex organizational system can be associated with suboptimal outcomes. Purpose To apply a sociotechnical systems perspective to investigate complexity in RTW; to utilize system dynamics modeling (SDM) to examine how feedback relationships between individual, psychosocial, and organizational factors make up the work disability system and influence RTW. Methods SDMs were developed within two companies. Thirty stakeholders including senior managers, and frontline supervisors and workers participated in model building sessions. Participants were asked questions that elicited information about the structure of the work disability system and were translated into feedback loops. To parameterize the model, participants were asked to estimate the shape and magnitude of the relationship between key model components. Data from published literature were also accessed to supplement participant estimates. Data were entered into a model created in the software program Vensim. Simulations were conducted to examine how financial incentives and light duty work disability-related policies, utilized by the participating companies, influenced RTW likelihood and preparedness. Results The SDMs were multidimensional, including individual attitudinal characteristics, health factors, and organizational components. Among the causal pathways uncovered, psychosocial components including workplace social support, supervisor and co-worker pressure, and supervisor-frontline worker communication impacted RTW likelihood and preparedness. Interestingly, SDM simulations showed that work disability-related policies in both companies resulted in a diminishing or opposing impact on RTW preparedness and likelihood. Conclusion SDM provides a novel systems view of RTW. Policy and psychosocial component relationships within the system have important implications for RTW, and may contribute to unanticipated outcomes.

  1. Municipal solid waste system analysis through energy consumption and return approach.

    Science.gov (United States)

    Tomić, Tihomir; Schneider, Daniel Rolph

    2017-12-01

    Inappropriate waste management and poor resource efficiency are two of the biggest problems which European Union is trying to solve through Landfill Directive, Waste Framework Directive and Circular Economy Package by increasing recycling and reuse and reducing waste disposal. In order to meet set goals, new European Union member states must quickly change national legislature and implement appropriate solutions. In the circumstances of strong EU resource and energy dependence, decision makers need to analyse which of the considered waste management systems leads to higher overall benefits ie. which is more sustainable. The main problem in this kind of analysis is a wide range of possible technologies and the difference in inputs and outputs. Sustainability of these systems is analysed through single-score LCA based assessment, using primary energy used to produce materials and energy vectors as a common measure. To ensure reliable results, interoperability between different data sources and material flows of waste and its components are monitored. Tracking external and internal material, and energy flows enable modelling of mutual interactions between different facilities. Resulting PERI, primary energy return based index, is used for comparison of different waste management scenarios. Results show that time and legislation dependent changes have great influence on decision making related to waste management and interconnected systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Infections Increase Risk of Arterial and Venous Thromboses in Danish Patients with Systemic Lupus Erythematosus

    DEFF Research Database (Denmark)

    Baronaite Hansen, Renata; Jacobsen, Søren

    2014-01-01

    OBJECTIVE: Infections and thromboses are known complications of systemic lupus erythematosus (SLE). We investigated if infectious episodes in patients with SLE were followed by an increased risk of thrombotic events. METHODS: A cohort of 571 patients with prevalent or incident SLE was followed...

  3. Preliminary assessment of rover power systems for the Mars Rover Sample Return Mission

    Science.gov (United States)

    Bents, D. J.

    1989-01-01

    Four isotope power system concepts were presented and compared on a common basis for application to on-board electrical prime power for an autonomous planetary rover vehicle. A representative design point corresponding to the Mars Rover Sample Return (MRSR) preliminary mission requirements (500 W) was selected for comparison purposes. All systems concepts utilize the General Purpose Heat Source (GPHS) isotope heat source developed by DOE. Two of the concepts employ thermoelectric (TE) conversion: one using the GPHS Radioisotope Thermoelectric Generator (RTG) used as a reference case, the other using an advanced RTG with improved thermoelectric materials. The other two concepts employed are dynamic isotope power systems (DIPS): one using a closed Brayton cycle (CBC) turboalternator, and the other using a free piston Stirling cycle engine/linear alternator (FPSE) with integrated heat source/heater head. Near-term technology levels have been assumed for concept characterization using component technology figure-of-merit values taken from the published literature. For example, the CBC characterization draws from the historical test database accumulated from space Brayton cycle subsystems and components from the NASA B engine through the mini-Brayton rotating unit. TE system performance is estimated from Voyager/multihundred Watt (MHW)-RTG flight experience through Mod-RTG performance estimates considering recent advances in TE materials under the DOD/DOE/NASA SP-100 and NASA Committee on Scientific and Technological Information programs. The Stirling DIPS system is characterized from scaled-down Space Power Demonstrator Engine (SPDE) data using the GPHS directly incorporated into the heater head. The characterization/comparison results presented here differ from previous comparison of isotope power (made for LEO applications) because of the elevated background temperature on the Martian surface compared to LEO, and the higher sensitivity of dynamic systems to elevated

  4. Evaluating the biological potential in samples returned from planetary satellites and small solar system bodies: framework for decision making

    National Research Council Canada - National Science Library

    National Research Council Staff; Space Studies Board; Division on Engineering and Physical Sciences; National Research Council; National Academy of Sciences

    ... from Planetary Satellites and Small Solar System Bodies Framework for Decision Making Task Group on Sample Return from Small Solar System Bodies Space Studies Board Commission on Physical Sciences, Mathematics, and Applications National Research Council NATIONAL ACADEMY PRESS Washington, D.C. 1998 i Copyrightthe true use are Please breaks...

  5. Evaluating the biological potential in samples returned from planetary satellites and small solar system bodies: framework for decision making

    National Research Council Canada - National Science Library

    National Research Council Staff

    1998-01-01

    ... from Planetary Satellites and Small Solar System Bodies Framework for Decision Making Task Group on Sample Return from Small Solar System Bodies Space Studies Board Commission on Physical Sciences, Mathematics, and Applications National Research Council NATIONAL ACADEMY PRESS Washington, D.C. 1998 i Copyrightthe true use are Please breaks...

  6. Prostacyclin Increases Portal Venous Flow.

    Science.gov (United States)

    1984-07-01

    decline in CO. If PCI 2 were administered for an unrelated disease when cirrhosis, portal hypertension, and esophageal varices were present, flow into...the portal system would increase and possibly initiate variceal hemorrhage. The portal venous effects of PGI should be 2realized when considering this

  7. Studies on venous chronic obstructions with perfused krypton-81m

    Energy Technology Data Exchange (ETDEWEB)

    Zicot, M.; Guillaume, M. (Universite de Liege, Centre de Recherches du Cyclotron (Belgium))

    1982-01-01

    A perfusion system is used to study the venous return of the lower limbs through an injection of a superficial vein of the foot. Multiple sequential perfusions are possible because there is no building up of the radioactivity (short-life of the Kr-81m and lung elimination). We are therefore able to study the system under different mechanical conditions (tourniquet at different sites and pressures, hyperaemia). The main veins (from popliteal vein to vena cava) are therefore normally vizualised by a peripheral injection. The region below the knee is difficult to study by venoscintigraphy. The transit times from the foot to the groin, and between regions of interest are also studied. We analyse the results obtained with a consecutive series of 31 patients suffering from possible chronic venous problems and sequelae of deep venous thrombosis (lasting for 2 weeks to more than 20 years): 58 limbs are actually examined. Most of these limbs are also assessed by non invasive heamodynamic techniques: Doppler ultrasound and calf plethysmography: 35 limbs are normal, 23 show obliterative sequelae of deep vein thrombosis. The venoscintigraphy displays the level and the degree of obstructions and the pattern of collateral pathways with an accuracy comparable to RX-phlebography. We demonstrate that the Doppler is able to recognize most of the residual obstructions. The resistances to venous outflow measured by plethysmography are also generally increased. We are not able to demonstrate systematic and significant variations of the transit times in the different haemodynamic conditions. These parameters do not seem therefore adequate for functional assessment.

  8. Studies on venous chronic obstructions with perfused krypton-81m

    International Nuclear Information System (INIS)

    Zicot, M.; Guillaume, M.

    1982-01-01

    A perfusion system is used to study the venous return of the lower limbs through an injection of a superficial vein of the foot. Multiple sequential perfusions are possible because there is no building up of the radioactivity (short-life of the Kr-81m and lung elimination). We are therefore able to study the system under different mechanical conditions (tourniquet at different sites and pressures, hyperaemia). The main veins (from popliteal vein to vena cava) are therefore normally vizualised by a peripheral injection. The region below the knee is difficult to study by venoscintigraphy. The transit times from the foot to the groin, and between regions of interest are also studied. We analyse the results obtained with a consecutive serie of 31 patients suffering from possible chronic venous problems and sequelae of deep venous thrombosis (lasting for 2 weeks to more than 20 years): 58 limbs are actually examined. Most of these limbs are also assessed by non invasive heamodynamic techniques: Doppler ultrasound and calf plethysmography: 35 limbs are normal, 23 show obliterative sequelae of deep vein thrombosis. The venoscintigraphy displays the level and the degree of obstructions and the pattern of collateral pathways with an accuracy comparable to RX-phlebography. We demonstrate that the Doppler is able to recognize most of the residual obstructions. The resistances to venous outflow measured by plethysmography are also generally increased. We are not able to demonstrate systematic and significant variations of the transit times in the different haemodynamic conditions. These parameters do not seem therefore adequate for functional assessment [fr

  9. The internal rate of return of photovoltaic grid-connected systems. A comprehensive sensitivity analysis

    International Nuclear Information System (INIS)

    Talavera, D.L.; Nofuentes, G.; Aguilera, J.

    2010-01-01

    At present, photovoltaic grid-connected systems (PVGCS) are experiencing a formidable market growth. This is mainly due to a continuous downward trend in PV cost together with some government support programmes launched by many developed countries. However, government bodies and prospective owners/investors are concerned with how changes in existing economic factors - financial incentives and main economic parameters of the PVGCS - that configure a given scenario may affect the profitability of the investment in these systems. Consequently, not only is a mere estimate of the economic profitability in a specific moment required, but also how this profitability may vary according to changes in the existing scenario. In order to enlighten decision-makers and prospective owners/investors of PVGCS, a sensitivity analysis of the internal rate of return (IRR) to some economic factors has been carried out. Three different scenarios have been assumed to represent the three top geographical markets for PV: the Euro area, the USA and Japan. The results obtained in this analysis provide clear evidence that annual loan interest, normalised initial investment subsidy, normalised annual PV electricity yield, PV electricity unitary price and normalised initial investment are ordered from the lowest to the highest impact on the IRR. A short and broad analysis concerning the taxation impact is also provided. (author)

  10. The function regulation of protein C system and novel high risk of venous thrombosis

    International Nuclear Information System (INIS)

    Jin Jian; Tao Yonghui; Zhang Lianfen; Zhang Rongjun; Zhang Manda; Wang Bocheng; He Yang; Bai Xia; Ruan Changgeng

    1999-12-01

    The procedures for isolation and purification of PC, PS, PCI and antithrombin III(ATIII) from human plasma and TM from human urine were developed. Five RIAs were also developed, on the equilibrium method, by raising the antisera in rabbits. 125 I-PC, 125 I-PS and 125 I-ATIII were prepared using the chloramine-T method, 125 I-PCI by Iodogen method and 125 I-TM by Bolton-Hunter method. All of their sensitivities were below 10 μg/L, and the ranges of recovery rates were 94.30% to 105.22%. The cross reactivities of these methods with factor II and thrombin (Th) were negligible. The functional regulation of protein C system with flow cytometry and the five RIAs was investigated. On the basis of the five RIAs. The technique of APC-APTT was developed, which is a simple and reliable method to detect APC-resistance. A PCR was also developed for identification and verification of G1691A transition or point mutation of factor V on homozygotes and heterozygotes. Even though the diagnostic level of APC-APTT were the same as. It is observed that factor V G1691A mutation incidence on Chinese is much lower than on North European. There may be other factors about APC-resistance, such as factor VIII mutation or factor V mutation but not on G1691 A in Chinese

  11. Chronic venous leg ulcers – role of topical zinc

    Directory of Open Access Journals (Sweden)

    Maher SF

    2015-06-01

    Full Text Available Sara F Maher Physical Therapy Program, Department of Healthcare Sciences, Wayne State University, Detroit, MI, USA Abstract: Topical zinc has been used in the treatment of wounds for over 3,000 years, and is reported to have antiseptic, astringent, anti-inflammatory, antimicrobial, and wound healing properties. Fourteen studies were identified and reviewed, to assess the efficacy of this treatment modality as either a bandage or skin protectant in the treatment of venous ulcers. The authors of three studies reported improved healing time or success rate in wounds treated with zinc-based products. However, the authors of one study attributed the faster healing rate mainly to the extra compression (that improved venous blood return, delivered by the non-elastic paste bandage, and not by the zinc oxide alone. The quality of evidence is fair, as 50% of the studies were conducted prior to 2000 and 50% of the studies utilized fewer than 45 patients randomized to two or more groups. Other treatments have been reported to be more cost-effective than zinc, including hydrocolloids, four-layer compression systems, and CircAid Thera-boots. Finally, zinc was reported to be less comfortable, less easy to use, and caused increased pain, in comparison to other products on the market. This literature review, therefore, demonstrated that current evidence is insufficient to determine the effectiveness of zinc-based products in the treatment of venous wounds. Future research is needed focusing on larger, high-quality trials with an emphasis on quality of life issues and cost-effectiveness of treatment. Keywords: chronic wounds, leg ulcers, venous insufficiency, topical zinc

  12. A Novel Stretch Sensor to Measure Venous Hemodynamics

    Directory of Open Access Journals (Sweden)

    Syrpailyne Wankhar

    2018-07-01

    Full Text Available Chronic venous insufficiency is a debilitating condition causing varicose veins and venous ulcers. The pathophysiology includes reflux and venous obstruction. The diagnosis is often made by clinical examination and confirmed by Venous Doppler studies. Plethysmography helps to quantitatively examine the reflux and diagnose the burden of deep venous pathology to better understand venous hemodynamics, which is not elicited by venous duplex examination alone. However, most of these tests are qualitative, expensive, and not easily available. In this paper, we demonstrate the potential use of a novel stretch sensor in the assessment of venous hemodynamics during different maneuvers by measuring the change in calf circumference. We designed the stretch sensor by using semiconductor strain gauges pasted onto a small metal bar to form a load cell. The elastic and Velcro material attached to the load cell form a belt. It converts the change in limb circumference to a proportional tension (force of distension when placed around the calf muscle. We recorded the change in limb circumference from arrays of stretch sensors by using an in-house data acquisition system. We calculated the venous volume (VV, venous filling index (VFI, ejection fraction (EF and residual venous volume (RVV on two normal subjects and on two patients to assess venous hemodynamics. The values (VV > 60 ml, VFI 60%, RVV 2ml/s, EF 35% in patients were comparable to those reported in the literature.

  13. Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system

    Science.gov (United States)

    Goo, Eun-Hoe; Kim, Sun-Ju; Dong, Kyung-Rae; Kim, Kwang-Choul; Chung, Woon-Kwan

    2016-09-01

    The purpose of this study is to evaluate the image quality in delineation of the portal venous systems with two different methods, breath-hold and non-breath-hold by using the 3D FLASH sequence. We used a 1.5 T system to obtain magnetic resonance(MR)images. Arterial and portal phase 3D FLASH images were obtained with breath-hold after a bolus injection of GD-DOTA. The detection of PVS on the MR angiograms was classified into three grades. First, the angiograms of the breath-hold method showed well the portal vein, the splenic vein and the superior mesenteric vein systems in 13 of 15 patients (86%) and the inferior mesenteric vein system in 6 of 15 patients (40%), Second, MR angiograms of the non-breath-hold method demonstrated the PVS and the SMV in 12 of 15 patients (80%) and the IMV in 5 of 15 patients (33%). Our study showed contrast-enhanced 3D FLASH MR angiography, together with the breath-hold technique, may provide reliable and accurate information on the portal venous system.

  14. History of venous leg ulcers.

    Science.gov (United States)

    Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G

    To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).

  15. Venous thromboembolism in women

    DEFF Research Database (Denmark)

    Group, ESHRE Capri Workshop; Skouby, Sven Olaf

    2013-01-01

    BACKGROUND Venous thromboembolism (VTE) is a specific reproductive health risk for women. METHODS Searches were performed in Medline and other databases. The selection criteria were high-quality studies and studies relevant to clinical reproductive medicine. Summaries were presented and discussed...... is associated with an inherited thrombophilia in men and women. Changes in the coagulation system and in the risk of clinical VTE in women also occur during pregnancy, with the use of reproductive hormones and as a consequence of ovarian stimulation when hyperstimulation syndrome and conception occur together...... therapy (HRT) increases the VTE risk 2- to 4-fold. There is a synergistic effect between thrombophilia and the various reproductive risks. Prevention of VTE during pregnancy should be offered to women with specific risk factors. In women who are at high risk, CHC and HRT should be avoided. CONCLUSIONS...

  16. Chronic venous disorders

    African Journals Online (AJOL)

    engage in social and occupational activities, reduce QoL, and impose financial constraints. CVD has a significant financial ... 'heaviness or aching' aggravated by prolonged standing and relieved by elevation. Additionally, chronic .... of image acquisition based on venous filling. Abnormalities in venous flow are depicted.

  17. Total Anomalous Pulmonary Venous Connection to the Portal Vein

    International Nuclear Information System (INIS)

    Wyttenbach, Marina; Carrel, Thierry; Schuepbach, Peter; Tschaeppeler, Heinz; Triller, Juergen

    1996-01-01

    Anomalous pulmonary venous return represents a rare congenital anomaly with wide anatomic and physiologic variability. We report a case of a newborn with a rare form of total infracardiac anomalous pulmonary venous connection (TAPVC). The pulmonary veins draining both lungs formed two vertical veins, which joined to a common pulmonary trunk below the diaphragm. This venous channel connected to the portal vein through the esophageal hiatus. The diagnosis was suggested by color Doppler sonography and confirmed by intravenous digital subtraction angiography, which allowed definition of the anatomy

  18. Safety and Efficacy of a Needle-free Powder Lidocaine Delivery System in Pediatric Patients Undergoing Venipuncture or Peripheral Venous Cannulation: Randomized Double-blind COMFORT-004 Trial.

    Science.gov (United States)

    Schmitz, Michael L; Zempsky, William T; Meyer, James M

    2015-08-01

    The goal of this study was to determine if a lidocaine hydrochloride monohydrate powder intradermal system designed to provide cutaneous analgesia is efficacious, safe, and tolerable for pediatric subjects compared with a sham placebo system. COMFORT-004, A Phase III, Randomized, Double-Blind, Placebo-Controlled Study to Confirm the Effectiveness and Safety of ALGRX 3268 in Pediatric Subjects, was a single-dose, parallel group study of children undergoing venipuncture or peripheral venous cannulation at the antecubital fossa or back of the hand. Included were subjects (3-18 years) in 3 age groups: 3-7, 8-12, and 13-18 years. Excluded were those with recent similar procedures or with implantable devices or skin pathologies at the anatomical site, insufficient cognitive skills, or allergies to local anesthetics or adhesives. Subjects were randomized to receive the needle-free powder lidocaine delivery system (active system, 0.5 mg of lidocaine/21 ± 1 bar of pressure [n = 269]) or sham placebo (n = 266) 1-3 minutes before venipuncture or peripheral venous cannulation. Analgesic efficacy was assessed patient self-report of venous access pain (Wong-Baker FACES Pain Rating Scale [3-18 years] and visual analog scale [VAS; 8-18 years]) and parental observational VAS. Safety assessments included adverse events (AEs) and relationship to study treatment. Skin signs and symptoms were graded numerically. Wong-Baker FACES scores, VAS, and parental VAS were analyzed by using an ANOVA model. Responder ratings and success rates were compared by using a Cochran-Mantel-Haenszel test stratified according to center, age group, and body site. The active system group had significantly (P = 0.0022) less pain compared with the sham placebo in all age groups combined according to the modified Wong-Baker FACES scale. Secondary efficacy analyses found that the active system resulted in less pain as assessed by subjects' VAS pain assessments aged 8-18 years (P = 0.1856), responder analysis (P

  19. Normal venous anatomy and physiology of the lower extremity.

    Science.gov (United States)

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  20. Quantitative ColourDopplerSonography evaluation of cerebral venous outflow: a comparative study between patients with multiple sclerosis and controls.

    Science.gov (United States)

    Monti, Lucia; Menci, Elisabetta; Ulivelli, Monica; Cerase, Alfonso; Bartalini, Sabina; Piu, Pietro; Marotti, Nicola; Leonini, Sara; Galluzzi, Paolo; Romano, Daniele G; Casasco, Alfredo E; Venturi, Carlo

    2011-01-01

    Internal Jugular Veins (IJVs) are the principle outflow pathway for intracranial blood in clinostatism condition. In the seated position, IJVs collapse, while Vertebral Veins (VVs) increase the venous outflow and partially compensate the venous drainage. Spinal Epidural Veins are an additional drainage pathway in the seated position. Colour- Doppler-Sonography (CDS) examination is able to demonstrate IJVs and VVs outflow in different postural and respiratory conditions. The purpose of this study was to evaluate CDS quantification of the cerebral venous outflow (CVF) in healthy subjects and patients with multiple sclerosis (MS). In a group of 27 healthy adults (13 females and 14 males; mean age 37.8 ± 11.2 years), and 52 patients with MS (32 females and 20 males; mean age 42.6 ± 12.1 years), CVF has been measured in clinostatism and in the seated position as the sum of the flow in IJVs and VVs. The difference between CVF in clinostatism and CVF in the seated position (ΔCVF) has been correlated with patients' status (healthy or MS), and a number of clinical variables in MS patients. Statistical analysis was performed by Fisher's exact test, non-parametric Mann-Whitney U test, ANOVA Kruskal-Wallis test, and correntropy coefficient. The value of ΔCVF was negative in 59.6% of patients with MS and positive in 96.3% of healthy subjects. Negative ΔCVF values were significantly associated with MS (p<0.0001). There was no significant correlation with clinical variables. Negative ΔCVF has a hemodynamic significance, since it reflects an increased venous return in the seated position. This seems to be a pathologic condition. In MS patients, a vascular dysregulation resulting from involvement of the autonomous nervous system may be supposed. ΔCVF value should be included in the quantitative CDS evaluation of the cerebral venous drainage, in order to identify cerebral venous return abnormalities.

  1. Quantitative ColourDopplerSonography evaluation of cerebral venous outflow: a comparative study between patients with multiple sclerosis and controls.

    Directory of Open Access Journals (Sweden)

    Lucia Monti

    Full Text Available Internal Jugular Veins (IJVs are the principle outflow pathway for intracranial blood in clinostatism condition. In the seated position, IJVs collapse, while Vertebral Veins (VVs increase the venous outflow and partially compensate the venous drainage. Spinal Epidural Veins are an additional drainage pathway in the seated position. Colour- Doppler-Sonography (CDS examination is able to demonstrate IJVs and VVs outflow in different postural and respiratory conditions. The purpose of this study was to evaluate CDS quantification of the cerebral venous outflow (CVF in healthy subjects and patients with multiple sclerosis (MS.In a group of 27 healthy adults (13 females and 14 males; mean age 37.8 ± 11.2 years, and 52 patients with MS (32 females and 20 males; mean age 42.6 ± 12.1 years, CVF has been measured in clinostatism and in the seated position as the sum of the flow in IJVs and VVs. The difference between CVF in clinostatism and CVF in the seated position (ΔCVF has been correlated with patients' status (healthy or MS, and a number of clinical variables in MS patients. Statistical analysis was performed by Fisher's exact test, non-parametric Mann-Whitney U test, ANOVA Kruskal-Wallis test, and correntropy coefficient. The value of ΔCVF was negative in 59.6% of patients with MS and positive in 96.3% of healthy subjects. Negative ΔCVF values were significantly associated with MS (p<0.0001. There was no significant correlation with clinical variables.Negative ΔCVF has a hemodynamic significance, since it reflects an increased venous return in the seated position. This seems to be a pathologic condition. In MS patients, a vascular dysregulation resulting from involvement of the autonomous nervous system may be supposed. ΔCVF value should be included in the quantitative CDS evaluation of the cerebral venous drainage, in order to identify cerebral venous return abnormalities.

  2. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    Science.gov (United States)

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2017-01-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  3. Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

    International Nuclear Information System (INIS)

    Goltz, Jan P.; Scholl, Anne; Ritter, Christian O.; Wittenberg, Guenther; Hahn, Dietbert; Kickuth, Ralph

    2010-01-01

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

  4. Radio-nuclide angiocardiography combined with Swan-Ganz catheter for the estimation of volume-pressure curves of the pulmonary ''venous'' system in man

    International Nuclear Information System (INIS)

    Gotoh, K.; Hirakawa, S.; Suzuki, T.; Fujiwara, H.; Ohsumi, Y.; Yagi, Y.

    1983-01-01

    Short segments of volume-pressure (V-P) curves of the pulmonary ''venous'' (P''V'') system, consisting of the pulmonary veins and left atrium, were estimated in 31 patients. Pulmonary blood volume (PBV) was estimated by our new method, using RN-angiocardiography. Increments in PBV and mean pulmonary artery wedge (PAW) pressure, that occur during passive-elevation of both legs, were clues to the estimation of the compliance (ΔV/ΔP) of this system. Sublingual administration of nitroglycerin (NTG) caused the short segments of V-P curves to shift to the left almost horizontally but slightly downwards, associated with a considerable increase in ΔV/ΔP. It is suggested that NTG causes, among other things, relaxation of the walls of P''V'' system

  5. Evaluation and comparison of return of investment for proposed use of solar systems in the Czech and Slovak Republic

    Directory of Open Access Journals (Sweden)

    E. Weiss

    2012-07-01

    Full Text Available The aim of the paper is to evaluate return of investment (ROI and cost savings from proposed use of solar systems for residents funded by government grants. The paper deals with proposals for solar energy systems for various use, simple calculations of payback periods of solar systems financed with subsidy and without subsidy. Apart from climatic conditions, chemical composition the of the absorber and structural elements that are made of copper, respectively aluminum and Al-Mg alloy play an important role in assessing the payback period of the investment in solar panels.

  6. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  7. The "toxic dose" of system problems: why some injured workers don't return to work as expected.

    Science.gov (United States)

    MacEachen, Ellen; Kosny, Agnieszka; Ferrier, Sue; Chambers, Lori

    2010-09-01

    Introduction Most workers who incur an injury on the job follow a relatively straightforward path through a workers' compensation claim, recovery and return to work. However, a minority of compensation claims is prolonged and can be disproportionately costly. We conducted this qualitative study in order to gain an understanding of systemic, process-related problems affecting injured workers who had failed to return to work as expected. Method A total of 69 in-depth interviews were conducted with injured workers with complex and extended workers' compensation claims and with return-to-work (RTW) providers such as health care providers, insurers, legal advisors, and workplaces. The study was based in Ontario, Canada. A modified grounded theory analysis led to the identification of common mechanisms in RTW problems. Results We identify problems with return to work and extended workers' compensation claims in dysfunctions in organizational dynamics across RTW systems including the workplace, healthcare, vocational rehabilitation and workers' compensation. These system problems are difficult to identify because they appear as relatively mundane and bureaucratic. These appeared to have damaging effects on workers in the form of a 'toxic dose' affecting the worker beyond the initial injury. Conclusions Worker's problems with extended claims were linked to RTW policies that did not easily accommodate conflict or power imbalances among RTW parties and by social relations and processes that impeded communication about RTW situations and problems. Avenues for intervention are located in a shift to a critical lens to RTW process that addresses differences of knowledge, resources, and interests among different parties.

  8. Venous thrombosis: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, C.W.

    1986-07-01

    Venous thromboembolic disease contributes to morbidity and mortality in certain groups of hospitalized patients, particularly those who have undergone surgery. Although principles of treatment have changed relatively little during the past 20 years, significant advances have been made in the diagnosis of deep vein thrombosis (DVT). Venography, once the only reliable diagnostic technique, has been largely replaced by noninvasive tests: impedance plethysmography, venous Doppler, /sup 125/I-radiofibrinogen-uptake test, and phleborheography. Virchow's triad of stasis, vessel injury, and hypercoagulability remains a valid explanation of the pathogenesis of thrombus formation, but laboratory and clinical data have refined our knowledge of how these factors interact to result in clinically significant disease. Knowledge of the natural history of venous thrombosis, plus heightened awareness of the long-term morbidity and expense associated with the postphlebitic syndrome, have led to increased interest in preventing DVT. Clinically and economically, venous thrombosis is best managed by prevention. 61 references.

  9. Venous thrombosis - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100168.htm Venous thrombosis - series—Normal anatomy To use the sharing features ... Editorial team. Related MedlinePlus Health Topics Deep Vein Thrombosis A.D.A.M., Inc. is accredited by ...

  10. Venous leg ulcers.

    Science.gov (United States)

    Nelson, E Andrea; Adderley, Una

    2016-01-15

    Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0 in 1000 people have active leg ulcers. Prevalence increases with age to about 20 in 1000 people aged over 80 years. We conducted a systematic overview, aiming to answer the following clinical questions: What are the effects of treatments for venous leg ulcers? What are the effects of organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to March 2014 (Clinical Evidence overviews are updated periodically; please check our website for the most up-to-date version of this overview). At this update, searching of electronic databases retrieved 116 studies. After deduplication and removal of conference abstracts, 63 records were screened for inclusion in the overview. Appraisal of titles and abstracts led to the exclusion of 43 studies and the further review of 20 full publications. Of the 20 full articles evaluated, four systematic reviews were updated and four RCTs were added at this update. We performed a GRADE evaluation for 23 PICO combinations. In this systematic overview, we categorised the efficacy for 13 interventions based on information about the effectiveness and safety of advice to elevate leg, advice to keep leg active, compression stockings for prevention of recurrence, compression bandages and stockings to treat venous leg ulcers, laser treatment (low level), leg ulcer clinics, pentoxifylline, skin grafting, superficial vein surgery for prevention of recurrence, superficial vein surgery to treat venous leg ulcers, therapeutic ultrasound, and topical negative pressure.

  11. Venous ulcer review

    Science.gov (United States)

    Bevis, Paul; Earnshaw, Jonothan

    2011-01-01

    Clinical question: What is the best treatment for venous ulcers? Results: Compression aids ulcer healing. Pentoxifylline can aid ulcer healing. Artificial skin grafts are more effective than other skin grafts in helping ulcer healing. Correction of underlying venous incompetence reduces ulcer recurrence. Implementation: Potential pitfalls to avoid are: Failure to exclude underlying arterial disease before application of compression.Unusual-looking ulcers or those slow to heal should be biopsied to exclude malignant transformation. PMID:21673869

  12. Venous ulcer review

    OpenAIRE

    Bevis, Paul; Earnshaw, Jonothan

    2011-01-01

    Paul Bevis, Jonothan Earnshaw Department of Vascular Surgery, Gloucestershire Royal Hospital, Great Western Road, Gloucester, UKDate of preparation: 3 February 2011Conflict of interest: None declared.Clinical question: What is the best treatment for venous ulcers?Results: Compression aids ulcer healing. Pentoxifylline can aid ulcer healing. Artificial skin grafts are more effective than other skin grafts in helping ulcer healing. Correction of underlying venous incompetence reduces ulcer recu...

  13. Prophylaxis of Venous Thrombosis.

    Science.gov (United States)

    Goldhaber, Samuel Z.

    2001-06-01

    Mechanical measures such as graduated compression stockings and intermittent compression boots are available for venous thrombosis prophylaxis, but compliance may be limited. Plantar venous pneumatic compression devices have attained widespread acceptance by both patients and nurses because of their comfort and compact size, but their track record for efficacy is poor. Inferior vena cava filters prevent pulmonary embolism, but do not halt the thrombotic process or prevent venous thrombosis. Pharmacologic prophylaxis traditionally has relied upon minidose unfractionated heparin; however, re-examination is warranted in the face of increasingly ill and complex patients. My opinion is that small, fixed doses of once-daily low molecular weight heparin will eventually replace minidose unfractionated heparin as the standard pharmacologic prophylaxis regimen for most surgical and medical patients. Prolongation of prophylaxis after hospital discharge should receive increased emphasis. Most patients being transferred to a skilled nursing facility should receive venous thromboembolism prophylaxis. Similarly, most patients undergoing total hip or knee replacement should receive prolonged preventive regimens, with at least 1 month of anticoagulation. Despite advances, certain aspects of venous thrombosis prophylaxis remain problematic. First, a surprisingly high number of hospitalized patients develop venous thrombosis because of failed (rather than omitted) prophylaxis. Second, many patients in intensive care have a combination of peripheral vascular disease and active bleeding (usually gastrointestinal) that precludes mechanical or pharmacologic prophylaxis. Third, neurosurgical patients undergoing craniotomy for brain tumors suffer a high rate of venous thrombosis and major pulmonary embolism despite the routine use of combined mechanical and pharmacologic prophylaxis. My opinion is that these three areas, in addition to the hospital culture of prophylaxis, should receive

  14. A newborn liver mass that never existed: a somber reminder of embryonic ties between umbilical vein and portal venous system

    Directory of Open Access Journals (Sweden)

    Haafiz A

    2011-12-01

    Full Text Available Allah Haafiz1, Jonathan L Williams2, Joel M Andres1, Don A Novak11Pediatric Gastroenterology, Hepatology; 2Department of Pediatric Radiology, University of Florida College of Medicine, Gainesville, FL, USAAbstract: A 6-day-old, known to have transposition of the great vessels, received care in the neonatal intensive care unit at a tertiary care center. A computed tomography scan was performed for abdominal distention and upper gastrointestinal bleeding, which revealed a “mass lesion” in the left liver lobe. Analysis of antecedent events and the clinical and laboratory course uncovered an iatrogenic etiology and pathogenesis of the lesion. As the nature of the lesion was clarified, no specific therapy was required. This case is presented to show a serious yet preventable complication of a commonly performed procedure.Keywords: portal vein thrombosis, liver mass, umbilical venous catheter

  15. An unusual cause of hydrocephalus: aqueductal developmental venous anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Yagmurlu, Banu; Fitoz, Suat; Atasoy, Cetin; Erden, ilhan [Ankara University School of Medicine, Department of Radiology, Ankara (Turkey); Deda, Gulhis; Unal, Ozlem [Ankara University School of Medicine, Division of Pediatric Neurology, Ankara (Turkey)

    2005-06-01

    Vascular malformations are infrequent causes of aqueductal stenoses, developmental venous anomaly (DVA) being the rarest among them. DVAs, also known as venous angiomas, are congenital in origin and characterized by dilatation of vessels in the superficial and deep venous system. Although they are usually clinically silent, they can be complicated by hemorrhage, seizures and neurologic deficits. Herein, we report MR imaging findings of a 7-year-old girl whose hydrocephalus was due to an abnormal vein coursing through the aqueduct. (orig.)

  16. Early aggressive intra-venous pulse cyclophosphamide therapy for interstitial lung disease in a patient with systemic sclerosis. A case report.

    LENUS (Irish Health Repository)

    Peshin, R

    2009-06-01

    Interstitial lung disease is an important cause of mortality and morbidity in patients with systemic sclerosis (SSc). There are currently no recommended guidelines for management of these patients. This is probably due to the rarity of this condition, as well as clinical trials with only a small number of cases. There are published case report and case series along with the two main trials, viz. Scleroderma Lung Study and the Fibrosing Alveolitis Study, but again, there is no consensus on treatment protocols. In this report, we present a case of aggressive interstitial lung disease in a patient with SSc, which improved dramatically on treatment with intra-venous cyclophosphamide and high dose prednisolone therapy.

  17. Brain venous pathologies: MRI findings

    International Nuclear Information System (INIS)

    Salvatico, Rosana; Gonzalez, Alejandro; Yanez, Paulina; Romero, Carlos; Trejo, Mariano; Lambre, Hector

    2006-01-01

    Purpose: To describe MRI findings of the different brain venous pathologies. Material and Methods: Between January 2002 and March 2004, 18 patients were studied 10 males and 8 females between 6 and 63 years old; with different brain venous pathologies. In all cases brain MRI were performed including morphological sequences with and without gadolinium injection and angiographic venous sequences. Results: 10 venous occlusions were found, 6 venous angiomas, and 2 presented varices secondary to arteriovenous dural fistula. Conclusion: Brain venous pathologies can appear in many different clinical contexts, with different prognosis and treatment. In all the cases brain MRI was the best imaging study to disclose typical morphologic abnormalities. (author) [es

  18. Development of a New Transportation/Storage Cask System for Use by the DOE Russian Research Reactor Fuel Return Program

    Energy Technology Data Exchange (ETDEWEB)

    Michael J. Tyacke; Frantisek Svitak; Jiri Rychecky; Miroslav Picek; Alexey Smirnov; Sergey Komarov; Edward Bradley; Alexander Dudchenko; Konstantin Golubkin

    2007-10-01

    The United States, the Russian Federation, and the International Atomic Energy Agency (IAEA) have been working together on a program called the Russian Research Reactor Fuel Return (RRRFR) Program. The purpose of this program is to return Soviet or Russian-supplied high-enriched uranium (HEU) fuel, currently stored at Russian-designed research reactors throughout the world, to Russia. To accommodate transport of the HEU spent nuclear fuel (SNF), a new large-capacity transport/storage cask system was specially designed for handling and operations under the unique conditions at these research reactor facilities. This new cask system is named the ŠKODA VPVR/M cask. The design, licensing, testing, and delivery of this new cask system result from a significant international cooperative effort by several countries and involved numerous private and governmental organizations. This paper contains the following sections: 1) Introduction; 2) VPVR/M Cask Description; 3) Ancillary Equipment, 4) Cask Licensing; 5) Cask Demonstration and Operations; 6) IAEA Procurement, Quality Assurance Inspections, Fabrication, and Delivery; and, 7) Conclusions.

  19. Venous hemodynamic changes in lower limb venous disease

    DEFF Research Database (Denmark)

    Lee, Byung Boong; Nicolaides, Andrew N; Myers, Kenneth

    2016-01-01

    aspects of management for venous disease by evidence-based principles. These included experts from various member societies including the European Venous Forum (EVF), American Venous Forum (AVF), American College of Phlebology (ACP) and Cardiovascular Disease Educational and Research Trust (CDERT...

  20. Direct venous thrombolysis and venous angioplasty in the upper extremity

    International Nuclear Information System (INIS)

    Hollmann, J.P.; Guenther, R.W.

    1987-01-01

    Venous thromboses of stenoses in the upper extremity are often the result of a compression syndrome of the shoulder girdle, the Paget-von Schroetter syndrome, vascular surgery, space-occupying lesions in the mediastinum or the result of catheterisation. Direct venous thrombolysis and venous angioplasty were performed successfully in six patients. (orig.) [de

  1. Chronic venous disease.

    Science.gov (United States)

    Wolinsky, Claire D; Waldorf, Heidi

    2009-11-01

    Identifying characteristic cutaneous findings is important in determining the appropriate management of certain venous diseases. The health care provider should be familiar with the classic description of patterns and distributions of skin manifestations, such as varicose veins, stasis dermatitis, palpable cord, petechiae, and telangiectasias. In addition to the gross appearance of the skin, a skin biopsy may help elucidate a diagnosis. General treatment and prevention of the underlying venous pathology is essential. Furthermore, specific management of skin findings should include therapy to ameliorate progression of disease and symptomatology when warranted.

  2. Three-dimensional reconstruction of the lower limb's venous system in human fetuses using the computer-assisted anatomical dissection (CAAD) technique.

    Science.gov (United States)

    Kurobe, N; Hakkakian, L; Chahim, M; Delmas, V; Vekemans, M; Uhl, J F

    2015-04-01

    The aim of the present study was to show the feasibility and describe the first results of a 3D reconstruction of the venous network of the lower limbs in human fetus using the computer-assisted anatomical dissection (CAAD) technique. We used limbs from two human fetuses, respectively, 14 and 15 weeks gestation old. Specimens were fixed in 10% formalin, embedded in paraffin wax and serially sectioned at 10 m. The histological slices were stained using HES and Masson Trichrome for soft tissues identification. Immunolabeling techniques using the Protein S-100 marker and the D2-40 marker were used to identify nerves and vessels, respectively. Stained slices were aligned manually, labeled and digitalized. The segmentation of all anatomical structures was achieved using the WinSurf(®) software after manual drawing. A 3D interactive vectorial model of the whole leg, including skin, bone, muscles, arteries, veins, and nerves was obtained. In all limbs, we observed the presence of a big axial vein traveling along the sciatic nerve. In addition, the femoral vein appeared as a small plexus. Although this is a common anatomical feature at the end of organogenesis, this feature is observed in only 9% of adults. Usually interpreted as an "anatomical variation of the femoral vein" it should be considered as a light truncular malformation. These observations bring further support to our proposed "angio-guiding nerves" hypothesis. This preliminary study shows that the CAAD technique provided an accurate 3D reconstruction of the fetal leg veins anatomy. It should bring a new insight for the understanding of the different steps of development of the human venous system.

  3. Hormonal contraception and venous thromboembolism

    DEFF Research Database (Denmark)

    Lidegaard, Øjvind; Milsom, Ian; Geirsson, Reynir Tomas

    2012-01-01

    New studies about the influence of hormonal contraception on the risk of venous thromboembolism (VTE) have been published.......New studies about the influence of hormonal contraception on the risk of venous thromboembolism (VTE) have been published....

  4. Adaptive Changes in the Vestibular System of Land Snail to a 30-Day Spaceflight and Readaptation on Return to Earth

    Directory of Open Access Journals (Sweden)

    Nikolay Aseyev

    2017-11-01

    Full Text Available The vestibular system receives a permanent influence from gravity and reflexively controls equilibrium. If we assume gravity has remained constant during the species' evolution, will its sensory system adapt to abrupt loss of that force? We address this question in the land snail Helix lucorum exposed to 30 days of near weightlessness aboard the Bion-M1 satellite, and studied geotactic behavior of postflight snails, differential gene expressions in statocyst transcriptome, and electrophysiological responses of mechanoreceptors to applied tilts. Each approach revealed plastic changes in the snail's vestibular system assumed in response to spaceflight. Absence of light during the mission also affected statocyst physiology, as revealed by comparison to dark-conditioned control groups. Readaptation to normal tilt responses occurred at ~20 h following return to Earth. Despite the permanence of gravity, the snail responded in a compensatory manner to its loss and readapted once gravity was restored.

  5. The Moon: A 100% Isolation Barrier for Earth During Exobiological Examination of Solar System Sample Return Missions

    Science.gov (United States)

    DiGregorio, B. E.

    2018-02-01

    The only 100% guarantee of protecting our planet's biosphere from a back contamination event is to use the Moon as a sample return examination facility to qualify samples for eventual return to Earth.

  6. Mechanical thrombectomy: an alternative for treating cerebral venous sinus thrombosis.

    Science.gov (United States)

    Izura Gómez, Marta; Misis Del Campo, Maite; Puyalto de Pablo, Paloma; Castaño Duque, Carlos

    2018-01-01

    We report the use of mechanical venous thrombectomy in 2 cases of cerebral venous sinus thrombosis in which the usual first-choice treatment with systemic anticoagulants was contraindicated. Our aim is to present this treatment as an alternative to consider when anticoagulants therapy is too risky or is contraindicated in critically ill patients.

  7. Cerebral venous thrombosis

    NARCIS (Netherlands)

    Silvis, Suzanne M.; de Sousa, Diana Aguiar; Ferro, José M.; Coutinho, Jonathan M.

    2017-01-01

    Cerebral venous thrombosis (CVT) is an important cause of stroke in young adults. Data from large international registries published in the past two decades have greatly improved our knowledge about the epidemiology, clinical manifestations and prognosis of CVT. The presentation of symptoms is

  8. Venous thromboembolism: The intricacies

    Directory of Open Access Journals (Sweden)

    Dutta T

    2009-01-01

    Full Text Available Venous thromboembolism (VTE has been a subject of great interest of late. Since Rudolph Virchow described the famous Virchow′s triad in 1856, there have been rapid strides in the understanding of the pathogenesis and factors responsible for it. Discovery of various thrombophilic factors, both primary and acquired, in the last 40 years has revolutionized prognostication and management of this potentially life-threatening condition due to its associated complication of pulmonary thromboembolism. Detailed genetic mapping and linkage analyses have been underlining the fact that VTE is a multifactorial disorder and a complex one. There are many gene-gene and gene-environment interactions that alter and magnify the clinical picture in this disorder. Point in case is pregnancy, where the risk of VTE is 100-150 times increased in the presence of Factor V Leiden, prothrombin mutation (Prothrombin 20210A and antithrombin deficiency. Risk of VTE associated with long-haul air flight has now been well recognized. Thrombotic events associated with antiphospholipid syndrome (APS are 70% venous and 30% arterial. Deep venous thrombosis and pulmonary embolism are the most common venous events, though unusual cases of catastrophes due to central vein thrombosis like renal vein thrombosis and Budd-Chiari syndrome (catastrophic APS may occur.

  9. Extended daily veno-venous high-flux haemodialysis in patients with acute renal failure and multiple organ dysfunction syndrome using a single path batch dialysis system.

    Science.gov (United States)

    Lonnemann, G; Floege, J; Kliem, V; Brunkhorst, R; Koch, K M

    2000-08-01

    In the treatment of acute renal failure in patients with multiple organ dysfunction syndrome (MODS), continuous renal replacement therapies (CRRT) are increasingly used because of excellent volume control in the presence of improved cardiovascular stability. Patients with MODS, however, are frequently catabolic and have a high urea generation rate requiring either cost-intensive high-volume CRRT or additional intermittent haemodialysis to provide adequate clearance of small-molecular waste products. We tested the closed-loop batch haemodialysis system (called Genius((R))) for the treatment of acute renal failure in patients with MODS in the intensive care unit. Blood flow and countercurrent dialysate flow were reduced to 70 ml/min. Thus the 75 l dialysate tank of the Genius((R)) system lasts for 18 h of extended single-path high-flux haemodialysis (18 h-HFD) using polysulphous F60 S((R)) dialysers. Blood pressure, body temperature, and venous blood temperature in the extracorporeal circuit (no heating of the dialysate), ultrafiltration rate, serum urea levels, dialyser urea clearance, and total urea removal were monitored. In addition we tested the bacteriological quality of the spent dialysate at the end of 18-h treatments. Twenty patients with acute renal failure and MODS were investigated. Averaged dialyser urea clearance was 59.8 ml/min (equal to 3.6 l/h or 64.8 l/day). Total removal of urea was 14.1+/-6.5 g/day keeping serum levels of urea below 13 mmol/l. Mean arterial pressure remained stable during the 18-h treatments with a mean ultrafiltration rate of 120 ml/h. The temperature in the venous blood tubing dropped by 5+/-0.5 degrees C during the 18-h treatment (0.28 degrees C/h) in the presence of unchanged core temperature in the patients. There was no bacterial growth in 2.5 l of spent dialysate (dialysis using the Genius((R)) system combines the benefits of CRRT (good cardiovascular stability, sterile dialysate) with the advantages of intermittent

  10. Returning home

    DEFF Research Database (Denmark)

    Agergaard, Jytte; Brøgger, Ditte

    2016-01-01

    flows. By focusing on these educational migrants, this paper explores how they connect to their rural homes. Guided by a critical reading of the migration-development scholarship, the paper examines how migrants and their relatives make sense of educational migrants’ remitting and returning practices......, and by comparing three groups of educational migrants, the migrants’ reasons for staying connected and sending remittances are scrutinized. The paper finds that although educational migrants do not generate extensive economic remittances for local development in Nepal, they stay connected to their rural homes...

  11. Gold Returns

    OpenAIRE

    Robert J. Barro; Sanjay P. Misra

    2013-01-01

    From 1836 to 2011, the average real rate of price change for gold in the United States is 1.1% per year and the standard deviation is 13.1%, implying a one-standard-deviation confidence band for the mean of (0.1%, 2.1%). The covariances of gold's real rate of price change with consumption and GDP growth rates are small and statistically insignificantly different from zero. These negligible covariances suggest that gold's expected real rate of return--which includes an unobserved dividend yiel...

  12. Development of a Wearable Sensor System for Dynamically Mapping the Behavior of an Energy Storing and Returning Prosthetic Foot

    Directory of Open Access Journals (Sweden)

    Hawkins James

    2016-06-01

    Full Text Available It has been recognized that that the design and prescription of Energy Storing and Returning prosthetic running feet are not well understood and that further information on their performance would be beneficial to increase this understanding. Dynamic analysis of an amputee wearing a prosthetic foot is typically performed using reflective markers and motion-capture systems. High-speed cameras and force plates are used to collect data of a few strides. This requires specialized and expensive equipment in an unrepresentative environment within a large area. Inertial Measurement Units are also capable of being used as wearable sensors but suffer from drift issues. This paper presents the development of a wearable sensing system that records the action of an Energy Storing and Returning prosthetic running foot (sagittal plane displacement and ground contact position which could have research and/or clinical applications. This is achieved using five standalone pieces of apparatus including foot-mounted pressure sensors and a rotary vario-resistive displacement transducer. It is demonstrated, through the collection of profiles for both foot deflection and ground contact point over the duration of a stride, that the system can be attached to an amputee’s prosthesis and used in a non-laboratory environment. It was found from the system that the prosthetic ground contact point, for the amputee tested, progresses along the effective metatarsal portion of the prosthetic foot towards the distal end of the prosthesis over the duration of the stride. Further investigation of the effective stiffness changes of the foot due to the progression of the contact point is warranted.

  13. Development of a Wearable Sensor System for Dynamically Mapping the Behavior of an Energy Storing and Returning Prosthetic Foot

    Science.gov (United States)

    Hawkins, James; Noroozi, Siamak; Dupac, Mihai; Sewell, Philip

    2016-06-01

    It has been recognized that that the design and prescription of Energy Storing and Returning prosthetic running feet are not well understood and that further information on their performance would be beneficial to increase this understanding. Dynamic analysis of an amputee wearing a prosthetic foot is typically performed using reflective markers and motion-capture systems. High-speed cameras and force plates are used to collect data of a few strides. This requires specialized and expensive equipment in an unrepresentative environment within a large area. Inertial Measurement Units are also capable of being used as wearable sensors but suffer from drift issues. This paper presents the development of a wearable sensing system that records the action of an Energy Storing and Returning prosthetic running foot (sagittal plane displacement and ground contact position) which could have research and/or clinical applications. This is achieved using five standalone pieces of apparatus including foot-mounted pressure sensors and a rotary vario-resistive displacement transducer. It is demonstrated, through the collection of profiles for both foot deflection and ground contact point over the duration of a stride, that the system can be attached to an amputee's prosthesis and used in a non-laboratory environment. It was found from the system that the prosthetic ground contact point, for the amputee tested, progresses along the effective metatarsal portion of the prosthetic foot towards the distal end of the prosthesis over the duration of the stride. Further investigation of the effective stiffness changes of the foot due to the progression of the contact point is warranted.

  14. Farm-scale costs and returns for second generation bioenergy cropping systems in the US Corn Belt

    International Nuclear Information System (INIS)

    Manatt, Robert K; Schulte, Lisa A; Hall, Richard B; Hallam, Arne; Heaton, Emily A; Gunther, Theo; Moore, Ken J

    2013-01-01

    While grain crops are meeting much of the initial need for biofuels in the US, cellulosic or second generation (2G) materials are mandated to provide a growing portion of biofuel feedstocks. We sought to inform development of a 2G crop portfolio by assessing the profitability of novel cropping systems that potentially mitigate the negative effects of grain-based biofuel crops on food supply and environmental quality. We analyzed farm-gate costs and returns of five systems from an ongoing experiment in central Iowa, USA. The continuous corn cropping system was most profitable under current market conditions, followed by a corn–soybean rotation that incorporated triticale as a 2G cover crop every third year, and a corn–switchgrass system. A novel triticale–hybrid aspen intercropping system had the highest yields over the long term, but could only surpass the profitability of the continuous corn system when biomass prices exceeded foreseeable market values. A triticale/sorghum double cropping system was deemed unviable. We perceive three ways 2G crops could become more cost competitive with grain crops: by (1) boosting yields through substantially greater investment in research and development, (2) increasing demand through substantially greater and sustained investment in new markets, and (3) developing new schemes to compensate farmers for environmental benefits associated with 2G crops. (letter)

  15. Farm-scale costs and returns for second generation bioenergy cropping systems in the US Corn Belt

    Science.gov (United States)

    Manatt, Robert K.; Hallam, Arne; Schulte, Lisa A.; Heaton, Emily A.; Gunther, Theo; Hall, Richard B.; Moore, Ken J.

    2013-09-01

    While grain crops are meeting much of the initial need for biofuels in the US, cellulosic or second generation (2G) materials are mandated to provide a growing portion of biofuel feedstocks. We sought to inform development of a 2G crop portfolio by assessing the profitability of novel cropping systems that potentially mitigate the negative effects of grain-based biofuel crops on food supply and environmental quality. We analyzed farm-gate costs and returns of five systems from an ongoing experiment in central Iowa, USA. The continuous corn cropping system was most profitable under current market conditions, followed by a corn-soybean rotation that incorporated triticale as a 2G cover crop every third year, and a corn-switchgrass system. A novel triticale-hybrid aspen intercropping system had the highest yields over the long term, but could only surpass the profitability of the continuous corn system when biomass prices exceeded foreseeable market values. A triticale/sorghum double cropping system was deemed unviable. We perceive three ways 2G crops could become more cost competitive with grain crops: by (1) boosting yields through substantially greater investment in research and development, (2) increasing demand through substantially greater and sustained investment in new markets, and (3) developing new schemes to compensate farmers for environmental benefits associated with 2G crops.

  16. Venous ulcer: what is new?

    Science.gov (United States)

    Raffetto, Joseph D; Marston, William A

    2011-01-01

    The pathophysiology of venous dermal abnormality in chronic venous ulcers is reflective of a complex interplay that involves sustained venous hypertension, inflammation, changes in the microcirculation, cytokine and matrix metalloproteinase activation, and altered cellular function. Red blood cells and macromolecules extravasate into the interstitium and activate endothelial cells. Endothelial expression of specific adhesion molecules recruits leukocytes and causes diapedesis of these cells into the dermal microvasculature, promoting an inflammatory response with activation of cytokines and proteinases. Altered cell function enhances a state of vulnerability in the surrounding tissues, initiating specific changes associated with venous disease. Ultimately, the persistent inflammatory-proteinase activity leads to advanced chronic venous insufficiency and ulcer formation. The mainstay of therapy in venous ulcer abnormality is correction of the underlying venous hypertension through compression therapy and/or surgery. Understanding the science involved in the pathophysiology of venous ulcer formation has led to the development of adjunctive treatment directed at the dysregulated molecular pathways. Randomized clinical trials are critical for determining the most effective evidence-based treatments for venous ulcer, and this review discusses important trials that have had a significant impact on venous ulcer healing. In addition, the authors have included subsections referred to as "Translational Implications for Therapy" in the basic science sections of the review to help bridge the basic science knowledge with clinical applications that may help to modulate the molecular abnormalities in the pathophysiologic cascade leading to venous ulcers.

  17. Fingertip replantation (zone I) without venous anastomosis: clinical experience and outcome analysis.

    Science.gov (United States)

    Huan, An-Shi; Regmi, Subhash; Gu, Jia-Xiang; Liu, Hong-Jun; Zhang, Wen-Zhong

    2016-01-01

    The purpose of this study was to report our experience of fingertip replantation without venous anastomosis using alternate method to counter post-operative venous congestion. 30 Patients (18 men and 12 women) with 30 fingertip amputations (Tamai zone I) were treated with artery-only anastomosis fingertip replantation between March 2010 and July 2014. Postoperative venous outflow was maintained by allowing bleeding through wound gaps combined with topical (12500 u :250mlNS) and systemic (4000 IU SC once daily) heparin. The outcomes of replantation were evaluated using standard evaluating systems. The average duration of hospital stay was 10 days (range 7-14 days). Twenty-eight (93 %) replanted fingertips survived. Five replanted fingertip experienced postoperative vascular crisis. The estimated post-operative blood loss was about 200-450 ml (mean, 292 ml). Follow-up period ranged from 12 to 24 months (average, 18 months). At final follow-up examinations, the average value of static two point discrimination test was 5.6 mm (range 3-9 mm) and Semmes-Weinstein monofilament test was 3.35 g (range 2.83-4.56 g). The mean range of motion of distal interphalangeal joint was 65.2° (range 0-90°) and all patients returned to their work within 7-18 weeks (average, 11 weeks). Artery-only fingertip replantation can provide satisfactory cosmetic and functional results. Adequate venous outflow can be obtained by allowing minimal external bleeding through wound gaps combined with topical and systemic heparin.

  18. Modeling return on investment for an electronic medical record system in Lilongwe, Malawi.

    Science.gov (United States)

    Driessen, Julia; Cioffi, Marco; Alide, Noor; Landis-Lewis, Zach; Gamadzi, Gervase; Gadabu, Oliver Jintha; Douglas, Gerald

    2013-01-01

    To model the financial effects of implementing a hospital-wide electronic medical record (EMR) system in a tertiary facility in Malawi. We evaluated three areas of impact: length of stay, transcription time, and laboratory use. We collected data on expenditures in these categories under the paper-based (pre-EMR) system, and then estimated reductions in each category based on findings from EMR systems in the USA and backed by ambulatory data from low-income settings. We compared these potential savings accrued over a period of 5 years with the costs of implementing the touchscreen point-of-care EMR system at that site. Estimated cost savings in length of stay, transcription time, and laboratory use totaled US$284 395 annually. When compared with the costs of installing and sustaining the EMR system, there is a net financial gain by the third year of operation. Over 5 years the estimated net benefit was US$613 681. Despite considering only three categories of savings, this analysis demonstrates the potential financial benefits of EMR systems in low-income settings. The results are robust to higher discount rates, and a net benefit is realized even under more conservative assumptions. This model demonstrates that financial benefits could be realized with an EMR system in a low-income setting. Further studies will examine these and other categories in greater detail, study the financial effects at different levels of organization, and benefit from post-implementation data. This model will be further improved by substituting its assumptions for evidence as we conduct more detailed studies.

  19. Performance of single wire earth return transformers with amorphous alloy core in a rural electric energy distribution system

    Directory of Open Access Journals (Sweden)

    Benedito Antonio Luciano

    2012-10-01

    Full Text Available In this paper are presented some considerations about the performance of single wire earth return amorphous alloy core transformers in comparison with conventional silicon steel sheets cores transformers used in rural electric energy distribution network. It has been recognized that amorphous metal core transformers improve electrical power distribution efficiency by reducing transformer core losses. This reduction is due to some electromagnetic properties of the amorphous alloys such as: high magnetic permeability, high resistivity, and low coercivity. Experimental results obtained with some single-phase, 60 Hz, 5 kVA amorphous core transformers installed in a rural area electric distribution system in Northern Brazil have been confirming their superior performance in comparison to identical nominal rated transformers built with conventional silicon steel cores, particularly with regard to the excitation power and to the no-load losses.

  20. Does the Institution of a Statewide Trauma System Reduce Preventable Mortality and Yield a Positive Return on Investment for Taxpayers?

    Science.gov (United States)

    Maxson, Todd; Mabry, Charles D; Sutherland, Michael J; Robertson, Ronald D; Booker, James O; Collins, Terry; Spencer, Horace J; Rinker, Charles F; Sanddal, Teri L; Sanddal, Nels D

    2017-04-01

    In July 2009, Arkansas began to annually fund $20 million for a statewide trauma system (TS). We studied injury deaths both pre-TS (2009) and post-TS (2013 to 2014), with attention to causes of preventive mortality, societal cost of those preventable mortality deaths, and benefit to tax payers of the lives saved. A multi-specialty trauma-expert panel met and reviewed records of 672 decedents (290 pre-TS and 382 post-TS) who met standardized inclusion criteria, were judged potentially salvageable, and were selected by a proportional sampling of the roughly 2,500 annual trauma deaths. Deaths were adjudicated into sub-categories of nonpreventable and preventable causes. The value of lives lost was calculated for those lives potentially saved in the post-TS period. Total preventable mortality was reduced from 30% of cases pre-TS to 16% of cases studied post-TS, a reduction of 14%. Extrapolating a 14% reduction of preventable mortality to the post-TS study period, using the same inclusion criteria of the post-TS, we calculate that 79 lives were saved in 2013 to 2014 due to the institution of a TS. Using a minimal standard estimate of $100,000 value for a life-year, a lifetime value of $2,365,000 per person was saved. This equates to an economic impact of the lives saved of almost $186 million annually, representing a 9-fold return on investment from the $20 million of annual state funding invested in the TS. The implementation of a TS in Arkansas during a 5-year period resulted in a reduction of the preventable death rate to 16% post-TS, and a 9-fold return on investment by the tax payer. Additional life-saving gains can be expected with ongoing financial support and additional system performance-improvement efforts. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Earth Entry Requirements for Mars, Europa and Enceladus Sample Return Missions: A Thermal Protection System Perspective

    Science.gov (United States)

    Venkatapathy, Ethiraj; Gage, Peter; Ellerby, Don; Mahzari, Milad; Peterson, Keith; Stackpoole, Mairead; Young, Zion

    2016-01-01

    This oral presentation will be given at the 13th International Planetary Probe Workshop on June 14th, 2016 and will cover the drivers for reliability and the challenges faced in selecting and designing the thermal protection system (TPS). In addition, an assessment is made on new emerging TPS related technologies that could help with designs to meet the planetary protection requirements to prevent backward (Earth) contamination by biohazardous samples.

  2. Venous thromboembolism and pregnancy

    Directory of Open Access Journals (Sweden)

    Maristella D’Uva

    2010-03-01

    Full Text Available Maristella D’Uva1, Pierpaolo Di Micco2, Ida Strina1, Giuseppe De Placido1Department of Obstetrics and Gynecology and Human Reproduction, “Federico II” University of Naples, Naples, Italy; 2Internal Medicine Division, Buonconsiglio Fatebenefratelli Hospital of Naples, Naples, ItalyAbstract: In recent decades, the association between a hypercoagulable state and its causes and adverse pregnancy outcome, in particular recurrent pregnancy loss (RPL has been studied extensively. Although the first studies were focused only on the association between thrombophilia and RPL, subsequent studies underlined also a potential role of antithrombotic treatment to prevent vascular complication such as venous thromboembolism (VTE during pregnancy. Thromboprophylaxis should be considered also for pregnant subjects carriers of molecular thrombophilia or that previously experienced VTE, in order to prevent VTE during pregnancy, while antithrombotic treatment for VTE should be performed during all pregnant periods.Keywords: thrombophilia, venous thromboembolism, recurrent pregnancy loss, factor V Leiden

  3. How a submarine returns to periscope depth: analysing complex socio-technical systems using Cognitive Work Analysis.

    Science.gov (United States)

    Stanton, Neville A; Bessell, Kevin

    2014-01-01

    This paper presents the application of Cognitive Work Analysis to the description of the functions, situations, activities, decisions, strategies, and competencies of a Trafalgar class submarine when performing the function of returning to periscope depth. All five phases of Cognitive Work Analysis are presented, namely: Work Domain Analysis, Control Task Analysis, Strategies Analysis, Social Organisation and Cooperation Analysis, and Worker Competencies Analysis. Complex socio-technical systems are difficult to analyse but Cognitive Work Analysis offers an integrated way of analysing complex systems with the core of functional means-ends analysis underlying all of the other representations. The joined-up analysis offers a coherent framework for understanding how socio-technical systems work. Data were collected through observation and interviews at different sites across the UK. The resultant representations present a statement of how the work domain and current activities are configured in this complex socio-technical system. This is intended to provide a baseline, from which all future conceptions of the domain may be compared. The strength of the analysis is in the multiple representations from which the constraints acting on the work may be analysed. Future research needs to challenge the assumptions behind these constraints in order to develop new ways of working. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. A Follow-up Study on Return to Work in the Year After Reporting an Occupational Injury Stratified by Outcome of the Workers' Compensation System

    DEFF Research Database (Denmark)

    Rudbeck, Marianne; Johansen, Jens Peter; Omland, Øyvind

    2018-01-01

    ) or slower (industrial accident) compared to claimants with recognized claim without compensation the subsequent year and at a faster rate after decision. CONCLUSIONS: Compensation claims and proceedings of the workers' compensation system probably increase time to return to work, other factors as health......OBJECTIVE: To compare return rates to work between different groups according to decision from the workers' compensation. METHOD: Register data on disability benefits were used to describe return rates to work in Kaplan-Meier curves and association with decision on compensation claims. Disability...... benefits were granted by the municipalities independently of any compensation claim if sick-listed. RESULTS: Claimants with ongoing claims were the group with the largest proportion remaining on disability benefits. Claimants with rejected claims returned to work at the same rate (occupational disease...

  5. Development of the RANCOR Rotary-Percussive Coring System for Mars Sample Return

    Science.gov (United States)

    Paulsen, Gale; Indyk, Stephen; Zacny, Kris

    2014-01-01

    A RANCOR drill was designed to fit a Mars Exploration Rover (MER) class vehicle. The low mass of 3 kg was achieved by using the same actuator for three functions: rotation, percussions, and core break-off. Initial testing of the drill exposed an unexpected behavior of an off-the-shelf sprag clutch used to couple and decouple rotary-percussive function from the core break off function. Failure of the sprag was due to the vibration induced during percussive drilling. The sprag clutch would back drive in conditions where it was expected to hold position. Although this did not affect the performance of the drill, it nevertheless reduced the quality of the cores produced. Ultimately, the sprag clutch was replaced with a custom ratchet system that allowed for some angular displacement without advancing in either direction. Replacing the sprag with the ratchet improved the collected core quality. Also, premature failure of a 300-series stainless steel percussion spring was observed. The 300-series percussion spring was ultimately replaced with a music wire spring based on performances of previously designed rotary-percussive drill systems.

  6. Sustainable Mars Sample Return

    Science.gov (United States)

    Alston, Christie; Hancock, Sean; Laub, Joshua; Perry, Christopher; Ash, Robert

    2011-01-01

    The proposed Mars sample return mission will be completed using natural Martian resources for the majority of its operations. The system uses the following technologies: In-Situ Propellant Production (ISPP), a methane-oxygen propelled Mars Ascent Vehicle (MAV), a carbon dioxide powered hopper, and a hydrogen fueled balloon system (large balloons and small weather balloons). The ISPP system will produce the hydrogen, methane, and oxygen using a Sabatier reactor. a water electrolysis cell, water extracted from the Martian surface, and carbon dioxide extracted from the Martian atmosphere. Indigenous hydrogen will fuel the balloon systems and locally-derived methane and oxygen will fuel the MAV for the return of a 50 kg sample to Earth. The ISPP system will have a production cycle of 800 days and the estimated overall mission length is 1355 days from Earth departure to return to low Earth orbit. Combining these advanced technologies will enable the proposed sample return mission to be executed with reduced initial launch mass and thus be more cost efficient. The successful completion of this mission will serve as the next step in the advancement of Mars exploration technology.

  7. The Importance of Sample Return in Establishing Chemical Evidence for Life on Mars or Other Solar System Bodies

    Science.gov (United States)

    Glavin, D. P.; Conrad, P.; Dworkin, J. P.; Eigenbrode, J.; Mahaffy, P. R.

    2011-01-01

    The search for evidence of life on Mars and elsewhere will continue to be one of the primary goals of NASA s robotic exploration program over the next decade. NASA and ESA are currently planning a series of robotic missions to Mars with the goal of understanding its climate, resources, and potential for harboring past or present life. One key goal will be the search for chemical biomarkers including complex organic compounds important in life on Earth. These include amino acids, the monomer building blocks of proteins and enzymes, nucleobases and sugars which form the backbone of DNA and RNA, and lipids, the structural components of cell membranes. Many of these organic compounds can also be formed abiotically as demonstrated by their prevalence in carbonaceous meteorites [1], though, their molecular characteristics may distinguish a biological source [2]. It is possible that in situ instruments may reveal such characteristics, however, return of the right sample (i.e. one with biosignatures or having a high probability of biosignatures) to Earth would allow for more intensive laboratory studies using a broad array of powerful instrumentation for bulk characterization, molecular detection, isotopic and enantiomeric compositions, and spatially resolved chemistry that may be required for confirmation of extant or extinct Martian life. Here we will discuss the current analytical capabilities and strategies for the detection of organics on the Mars Science Laboratory (MSL) using the Sample Analysis at Mars (SAM) instrument suite and how sample return missions from Mars and other targets of astrobiological interest will help advance our understanding of chemical biosignatures in the solar system.

  8. Bedside ROP screening and telemedicine interpretation integrated to a neonatal transport system: Economic aspects and return on investment analysis.

    Science.gov (United States)

    Kovács, Gábor; Somogyvári, Zsolt; Maka, Erika; Nagyjánosi, László

    Peter Cerny Ambulance Service - Premature Eye Rescue Program (PCA-PERP) uses digital retinal imaging (DRI) with remote interpretation in bedside ROP screening, which has advantages over binocular indirect ophthalmoscopy (BIO) in screening of premature newborns. We aimed to demonstrate that PCA-PERP provides good value for the money and to model the cost ramifications of a similar newly launched system. As DRI was demonstrated to have high diagnostic performance, only the costs of bedside DRI-based screening were compared to those of traditional transport and BIO-based screening (cost-minimization analysis). The total costs of investment and maintenance were analyzed with micro-costing method. A ten-year analysis time-horizon and service provider's perspective were applied. From the launch of PCA-PERP up to the end of 2014, 3722 bedside examinations were performed in the PCA covered central region of Hungary. From 2009 to 2014, PCA-PERP saved 92,248km and 3633 staff working hours, with an annual nominal cost-savings ranging from 17,435 to 35,140 Euro. The net present value was 127,847 Euro at the end of 2014, with a payback period of 4.1years and an internal rate of return of 20.8%. Our model presented the NPVs of different scenarios with different initial investments, annual number of transports and average transport distances. PCA-PERP as bedside screening with remote interpretation, when compared to a transport-based screening with BIO, produced better cost-savings from the perspective of the service provider and provided a return on initial investment within five years after the project initiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A Return to Innovative Engineering Design, Critical Thinking and Systems Engineering

    Science.gov (United States)

    Camarda, Charles J.

    2007-01-01

    I believe we are facing a critical time where innovative engineering design is of paramount importance to the success of our aerospace industry. However, the very qualities and attributes necessary for enhancing, educating, and mentoring a creative spirit are in decline in important areas. The importance of creativity and innovation in this country was emphasized by a special edition of the Harvard Business Review OnPoint entitled: "The Creative Company" which compiled a series of past and present articles on the subject of creativity and innovation and stressed its importance to our national economy. There is also a recognition of a lack of engineering, critical thinking and problem-solving skills in our education systems and a trend toward trying to enhance those skills by developing K-12 educational programs such as Project Lead the Way, "Science for All Americans", Benchmarks 2061 , etc. In addition, with respect to spacecraft development, we have a growing need for young to mid-level engineers with appropriate experience and skills in spacecraft design, development, analysis, testing, and systems engineering. As the Director of Engineering at NASA's Johnson Space Center, I realized that sustaining engineering support of an operational human spacecraft such as the Space Shuttle is decidedly different than engineering design and development skills necessary for designing a new spacecraft such as the Crew Exploration Vehicle of the Constellation Program. We learned a very important lesson post Columbia in that the Space Shuttle is truly an experimental and not an operational vehicle and the strict adherence to developed rules and processes and chains of command of an inherently bureaucratic organizational structure will not protect us from a host of known unknowns let alone unknown unknowns. There are no strict rules, processes, or procedures for understanding anomalous results of an experiment, anomalies with an experimental spacecraft like Shuttle, or in the

  10. Complete resolution of systemic venous baffle obstruction and baffle leak using the Gore Excluder covered stent in two patients with transposition of the great arteries and prior Mustard procedure.

    Science.gov (United States)

    Hill, Kevin D; Fudge, J Curt; Rhodes, John F

    2010-11-15

    We present two patients with a history of Mustard repair of transposition of the great arteries. Both patients presented with exertional limitation and demonstrated superior systemic venous baffle obstruction as well as multiple baffle leaks. In both patients stent relief of obstruction and baffle leak exclusion was accomplished using a combination of bare metal stents and the aortic extension portion of the Gore Excluder covered stent (W.L. Gore and Associates, Flagstaff, Arizona). Copyright © 2010 Wiley-Liss, Inc.

  11. Assistance protocol for venous ulcers patients: validation of contents

    Directory of Open Access Journals (Sweden)

    Daniele Vieira Dantas

    2013-07-01

    Full Text Available Venous ulcers require complex treatment and are responsible for significant morbidity and mortality rates. This study aims at identifying aspects validated by the jury for the preparation of an assistance protocol for venous ulcer sufferers. It is a descriptive and quantitative research, with 39 professionals (30 nurses, 7 doctors and two physiotherapists, held at the Onofre Lopes University Hospital, between April and July/2010. Data collection began through a questionnaire checklist. Analysis was performed through Statistical Package for Social Science 15.0, assessing compliance with guidelines. Results were the compositional aspects of the protocol: assessment of patient and lesion history/documentation, wound care/perilesional skin, dressing suggestion, use of antibiotics and pain treatment, surgical treatment/medication, improving venous return and relapse prevention, patient referral, professional training and referral/counter-referral. It was concluded that to compose the protocol, aspects related to diagnosis, treatment and injury prevention must be considered.

  12. Energy Return on Energy Invested (ERoEI) for photovoltaic solar systems in regions of moderate insolation

    International Nuclear Information System (INIS)

    Ferroni, Ferruccio; Hopkirk, Robert J.

    2016-01-01

    Many people believe renewable energy sources to be capable of substituting fossil or nuclear energy. However there exist very few scientifically sound studies, which apply due diligence to substantiating this impression. In the present paper, the case of photovoltaic power sources in regions of moderate insolation is analysed critically by using the concept of Energy Return on Energy Invested (ERoEI, also called EROI). But the methodology for calculating the ERoEI differs greatly from author-to-author. The main differences between solar PV Systems are between the current ERoEI and what is called the extended ERoEI (ERoEI EXT ). The current methodology recommended by the International Energy Agency is not strictly applicable for comparing photovoltaic (PV) power generation with other systems. The main reasons are due to the fact that on one hand, solar electricity is very material-intensive, labour-intensive and capital-intensive and on the other hand the solar radiation exhibits a rather low power density. - Highlights: •Data are available from several years of photovoltaic energy experience in northern Europe. •These are used to show the way to calculate a full, extended ERoEI. •The viability and sustainability in these latitudes of photovoltaic energy is questioned. •Use of photovoltaic technology is shown to result in creation of an energy sink.

  13. Absenteeism due to mental health problems and systems for return to work: an internet-based unmatched case-control study.

    Science.gov (United States)

    Doki, Shotaro; Sasahara, Shinichiro; Hirai, Yasuhito; Oi, Yuichi; Matsuzaki, Ichiyo

    2016-11-01

    The aim of this study was to investigate the risk factors for absenteeism due to mental health problems with regard to company characteristics and systems for return to work in Japan. This was an Internet-based unmatched case-control study. Two hundred and fifty-eight workers who experienced over 28 days of sick leave due to mental health problems (cases) and 258 workers who have not taken sick leave (controls) were recruited. Company characteristics and the awareness and presence of systems for return to work were analysed as indicators of absenteeism. A total of 501 workers were included in the analysis. Females were less likely to experience absenteeism when adjustments were made for both the awareness and presence of systems [odds ratio (OR) = 0.51 and 0.41, respectively]. Large companies showed an increased risk of having absentee workers than small companies. The awareness of a gradual resumption system and the presence of a sick pay system were related to absenteeism (OR = 2.75 and 2.40, respectively). The awareness and presence of systems for return to work are related to the long-term absenteeism. The predictors of sex and company size are also related to the experience of the long-term absenteeism. To understand the effect of systems for return to work on absenteeism due to mental problems, further studies are needed.

  14. Pattern of pressure gradient alterations after venous sinus stenting for idiopathic intracranial hypertension predicts stent-adjacent stenosis: a proposed classification system.

    Science.gov (United States)

    Raper, Daniel; Buell, Thomas J; Ding, Dale; Chen, Ching-Jen; Starke, Robert M; Liu, Kenneth C

    2018-04-01

    Venous sinus stenting (VSS) is a safe and effective treatment for idiopathic intracranial hypertension (IIH) with angiographic venous sinus stenosis. However, predictors of stent-adjacent stenosis (SAS) remain poorly defined. We performed a retrospective review of 47 patients with IIH and intracranial venous stenosis who underwent VSS with pre- and post-stent venography. Patient characteristics, treatments and outcomes were reviewed. Changes in pressure gradient after VSS were classified according to pattern of gradient resolution into types I-III. Type I gradient resolution, in which mean venous pressure (MVP) in the transverse sinus (TS) decreases towards MVP in the sigmoid sinus (SS), occurred in 18 patients (38.3%). Type II gradient resolution pattern, in which SS MVP increases towards that in the TS, occurred in 7patients (14.9%). Type III pattern, in which MVP equilibrates to a middle value, occurred in 22patients (46.8%). SAS occurred in 0%, 28.6%, and 22.7% of patients in types I, II and III, respectively. Compared with patients with type I gradient resolution, SAS was more common in those with type II (p=0.0181) and type III (p=0.0306) patterns. The pattern of change in the trans-stenosis venous pressure gradient may be predictive of SAS and is a useful tool for classifying the response of the venous obstruction to stenting. A type I pattern appears to represent the ideal response to VSS. Some patients with type II and III changes, particularly if they have other predictors of recurrent stenosis, may benefit from longer initial stent constructs. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Magnetic resonance imaging of the cardiac venous system and magnetic resonance-guided intubation of the coronary sinus in swine: a feasibility study.

    Science.gov (United States)

    Neizel, Mirja; Krämer, Nils; Schütte, Adrian; Schnackenburg, Bernhard; Krüger, Sascha; Kelm, Malte; Günther, Rolf W; Kühl, Harald P; Krombach, Gabriele A

    2010-08-01

    To visualize the coronary sinus using magnetic resonance (MR), and to demonstrate the feasibility of MR-guided intubation of the cardiac venous system (CVS) in swine. A total of 6 pigs were investigated. All experiments were performed using an interventional 1.5-Tesla MRI system. The CVS was visualized using an inversion-recovery navigator-gated whole-heart steady-state free-precession sequence after administration of gadobenate dimeglumine contrast agent. The coronary sinus was then intubated under MR-guidance with a passive MR-compatible guidewire modified by incorporation of iron oxide markers for improved visualization and a nonbraided Cobra-catheter. MR-guided interventions were monitored using a steady-state free-precession real-time imaging sequence. Time needed was measured for MR-guided intubation of the CVS and compared with the time needed for fluoroscopy guided intubation of the CVS. Visualization and intubation of the coronary sinus and its site branches was feasible in all cases. Time spent for MR-guided intubation of the CVS was comparable to time spent for fluoroscopy-guided intubation (8.2 +/- 2 minutes vs. 8.3 +/- 1.3 minutes; P = 0.85). MR-visualization and MR-guided intubation of the coronary sinus and its side branches is feasible. The feasibility of MR-guided intubation of the CVS might have relevance for procedures like cardiac resynchronization therapy and percutaneous transcatheter mitral annuloplasty, requiring improved 3-dimensional knowledge about cardiac vein anatomy in the near future.

  16. Cerebral venous thrombosis.

    Science.gov (United States)

    Ameri, A; Bousser, M G

    1992-02-01

    Neuroimagining facilities allow early recognition of cerebral venous thrombosis (CVT), which now appears far more common than previously assumed. The diagnosis remains difficult because of a wide spectrum of clinical presentation and a highly variable mode of onset. Numerous conditions (presently mostly noninfectious) can cause or predispose to CVT, which therefore requires an extensive etiologic work-up. The functional and vital prognosis is much better than classically thought with, in noninfectious CVT, a fatality rate of less than 10% and a complete recovery in over 70%. Although spontaneous recovery is possible, the efficacy of heparin is now well established.

  17. Technical complications during veno-venous extracorporeal membrane oxygenation and their relevance predicting a system-exchange--retrospective analysis of 265 cases.

    Directory of Open Access Journals (Sweden)

    Matthias Lubnow

    Full Text Available OBJECTIVES: Technical complications are a known hazard in veno-venous extracorporeal membrane oxygenation (vvECMO. Identifying these complications and predictive factors indicating a developing system-exchange was the goal of the study. METHODS: Retrospective study on prospectively collected data of technical complications including 265 adult patients (Regensburg ECMO Registry, 2009-2013 with acute respiratory failure treated with vvECMO. Alterations in blood flow resistance, gas transfer capability, hemolysis, coagulation and hemostasis parameters were evaluated in conjunction with a system-exchange in all patients with at least one exchange (n = 83. RESULTS: Values presented as median (interquartile range. Patient age was 50(36-60 years, the SOFA score 11(8-14.3 and the Murray lung injury Score 3.33(3.3-3.7. Cumulative ECMO support time 3411 days, 9(6-15 days per patient. Mechanical failure of the blood pump (n = 5, MO (n = 2 or cannula (n = 1 accounted for 10% of the exchanges. Acute clot formation within the pump head (visible clots, increase in plasma free hemoglobin (frHb, serum lactate dehydrogenase (LDH, n = 13 and MO (increase in pressure drop across the MO, n = 16 required an urgent system-exchange, of which nearly 50% could be foreseen by measuring the parameters mentioned below. Reasons for an elective system-exchange were worsening of gas transfer capability (n = 10 and device-related coagulation disorders (n = 32, either local fibrinolysis in the MO due to clot formation (increased D-dimers [DD], decreased platelet count; n = 24, or device-induced hyperfibrinolysis (increased DD, decreased fibrinogen [FG], decreased platelet count, diffuse bleeding tendency; n = 8, which could be reversed after system-exchange. Four MOs were exchanged due to suspicion of infection. CONCLUSIONS: The majority of ECMO system-exchanges could be predicted by regular inspection of the complete ECMO circuit, evaluation of gas exchange, pressure drop

  18. Percutaneous transcatheter closure of a large systemic to pulmonary venous fistulae in an adult patient after extracardiac fontan.

    Science.gov (United States)

    Healan, Steven; Varga, Peter; Shah, Atman P

    2015-09-01

    Vascular fistulae are frequent complications in patients who have undergone a Fontan operation for palliation of single ventricle physiology. Fistulae involving the pulmonary vasculature may result in progressive hypoxemia, pulmonary hemorrhage, and clinical symptoms. These are commonly managed by percutaneous transcatheter embolization utilizing coils, and more recently, vascular plugs and septal occluders. We present a clinical case of an adult patient who underwent an extracardiac Fontan procedure in childhood for univentricular physiology and presented with symptoms of systemic desaturation 10 years after his surgery. The patient was found to have a large fistula from the inferior vena cava to the right inferior pulmonary vein. The fistula was attempted to be closed with a 12 mm Amplatzer Septal Occluder (St. Jude Medical, St. Paul, MN). Angiography showed continued flow across the fistula, which was then successfully occluded with an 18 mm Amplatzer "Cribriform" Septal Occluder (St. Jude Medical, St. Paul, MN). The patient experienced immediate improvement in his systemic saturation, and demonstrates continued resolution of his symptomatic hypoxia on follow-up. This case illustrates an uncommon systemic to pulmonary vein fistula after Fontan, and a unique, successful embolization with two septal occluders, resulting in sustained symptomatic improvement. © 2015 Wiley Periodicals, Inc.

  19. A system for generating long streamflow records for study of floods of long return period: Phase 2

    International Nuclear Information System (INIS)

    Franz, D.D.; Kraeger, B.A.; Linsley, R.K.

    1989-02-01

    Knowledge of the return periods of large floods is required to make risk analyses for nuclear power plants subject to flooding from rivers. The system reported here combined the stochastic simulation of hourly rainfall data and daily pan evaporation data with the deterministic simulation of streamflow by using the synthetic rainfall and evaporation data as input to a calibrated rainfall runoff model. The sequence of annual maximum flood peaks from a synthetic record of 10,000 years or more was then analyzed to obtain estimates of flood frequency. The reasonableness of the flood frequency results must be evaluated on the degree of mimicry of the key characteristics of the observed rainfall data and the ability of the rainfall-runoff model to mimic the observed flood frequency during the calibration period. On this basis, the flood frequency results appeared to be a reasonable extrapolation of the data used in defining the model parameters. There is a need to develop regional parameters for the stochastic models and to conduct research on the relationship between the stochastic structure of rainfall and stochastic structure of flood frequency. The methodology is applicable, assuming a highly skilled analyst, to watersheds similar to those already tested

  20. Detecting binary non-return-to-zero data in free-space optical communication systems using FPGAs

    Science.gov (United States)

    Bui, Vy; Tran, Lan; El-Araby, Esam; Namazi, Nader M.

    2014-06-01

    High bandwidth, fast deployment with relatively low cost implementation are some of the important advantages of free space optical (FSO) communications. However, the atmospheric turbulence has a substantial impact on the quality of a laser beam propagating through the atmosphere. A new method was presented in [1] and [2] to perform bit synchronization and detection of binary Non-Return-to-Zero (NRZ) data from a free-space optical (FSO) communication link. It was shown that, when the data is binary NRZ with no modulation, the Haar wavelet transformation can effectively reduce the scintillation noise. In this paper, we leverage and modify the work presented in [1] in order to provide a real-time streaming hardware prototype. The applicability of these concepts will be demonstrated through providing the hardware prototype using one of the state-of-the-art reconfigurable hardware, namely Field Programmable Gate Arrays, and highly productive high-level design tools such as System Generator for DSP from Xilinx.

  1. Maximizing Science Return on Astrobiology and Planetary Missions Using Integrated Liquid-Handling Chemical Analysis Systems - A Status Report

    Science.gov (United States)

    Willis, P. A.; Mora, M. F.; Creamer, J. S.; Kehl, F.

    2016-10-01

    Our team has been developing all components required for liquid-based analysis on planetary missions. Here we summarize our progress in this area, and highlight enhancements to science return on NASA missions that these technologies could provide.

  2. Cerebral sinus venous thrombosis

    Directory of Open Access Journals (Sweden)

    Hernando Raphael Alvis-Miranda

    2013-01-01

    Full Text Available Cerebral sinus venous thrombosis (CSVT is a rare phenomenon that can be seen with some frequency in young patients. CSVT is a multifactorial condition with gender-related specific causes, with a wide clinical presentation, the leading causes differ between developed and developing countries, converting CSVT in a condition characterized by a highly variable clinical spectra, difficult diagnosis, variable etiologies and prognosis that requires fine medical skills and a high suspicious index. Patients who presents with CSVT should underwent to CT-scan venography (CVT and to the proper inquiry of the generating cause. This disease can affect the cerebral venous drainage and related anatomical structure. The symptoms may appear in relation to increased intracranial pressure imitating a pseudotumorcerebri. Prognosis depends on the early detection. Correcting the cause, generally the complications can be prevented. Mortality trends have diminished, and with the new technologies, surely it will continue. This work aims to review current knowledge about CSVT including its pathogenesis, etiology, clinical manifestations, diagnosis, and treatment.

  3. Venous Thromboembolism in Adolescents

    Directory of Open Access Journals (Sweden)

    Aneta Samková

    2012-01-01

    Full Text Available The incidence of venous thromboembolism (VTE during childhood is low with two peaks – neonatal and adolescent age. This retrospective study is focused on clinical characteristics of VTE during adolescence. The main goals are to assess the most frequent inherited and acquired risk factors and to evaluate the benefit of D-dimers in diagnostics of venous thromboemblism. The data of 18 adolescents were analysed – 16 girls (88.9%, 2 boys (11.1%. In 9 patients (50% thrombosis of the lower limb deep veins was diagnosed, six patients (33.3% suffered from symptomatic pulmonary embolism (PE and 3 patients (16.7% from thrombosis at unusual sites. One patient had an idiopathic VTE, the mean number of the inherited and acquired risk factors was 2.6. The most frequent inherited risk factor was Leiden mutation of factor V (27.8%. The most frequent acquired risk factor was oral contraception (OC in 12 out of 16 girls (75%. All of our patients on oral contraception had one or more additional risk factors. 10 out of 18 (55.6% patients with VTE had elevated activity of factor VIII. The sensitivity of D-dimers was low (50% in patients with distal lower limb thrombosis, but very high (100% in patients with PE.

  4. Chronic Venous Disease under pressure

    NARCIS (Netherlands)

    S.W.I. Reeder (Suzan)

    2013-01-01

    textabstractIn chapter 1 we provide a general introduction of this thesis. Chronic venous disease (CVD) is a common medical condition that affects 2-64% of the worldwide population and leads to leg ulcers in 1% of the Western population. Venous leg ulceration (VLU) has an unfavorable prognosis with

  5. Clinical overview of venous thromboembolism

    African Journals Online (AJOL)

    Venous thromboembolism (VTE) is the result of a venous blood clot formation which may manifest itself as deep vein thrombosis. (DVT) or pulmonary embolism (PE).1,2 DVT and PE are part of the same syndrome. However, important distinguishing factors in terms of epidemiology, diagnosis and treatment exist between.

  6. Impact of health care system delay in patients with ST-elevation myocardial infarction on return to labor market and work retirement

    DEFF Research Database (Denmark)

    Laut, Kristina Grønborg; Hjort, Jacob; Engstrøm, Thomas

    2014-01-01

    system delay and time to return to the labor market was analyzed using a competing-risk regression analysis. Association between system delay and time to retirement from work was analyzed using a Cox regression model. A total of 4,061 patients were included. Ninety-three percent returned to the labor......System delay (delay from emergency medical service call to reperfusion with primary percutaneous coronary intervention [PPCI]) is acknowledged as a performance measure in ST-elevation myocardial infarction (STEMI), as shorter system delay is associated with lower mortality. It is unknown whether...... system delay also impacts ability to stay in the labor market. Therefore, the aim of the study was to evaluate whether system delay is associated with duration of absence from work or time to retirement from work among patients with STEMI treated with PPCI. We conducted a population-based cohort study...

  7. VENOUS INSUFFICIENCY AND THROMBOEMBOLIC DISEASE IN BARIATRIC SURGERY PATIENTS

    Directory of Open Access Journals (Sweden)

    Bonno van BELLEN

    2013-09-01

    Full Text Available Context Morbid obesity is associated with various co-morbidities, including chronic venous insufficiency. Bariatric surgery is the only effective treatment for morbid obesity, but with potential risks and possible complications, including venous thromboembolism. Objective To determine the prevalence of clinical and ultrasonographic signs of chronic venous insufficiency in morbid obese patients in preparation for bariatric surgery and the incidence of post-operative venous thromboembolic disease. Methods Patients on work-up for bariatric surgery of Centro Terapêutico Especializado em Fígado (CETEFI and Pro-Gastro surgical teams of the Hospital Beneficência Portuguesa de São Paulo were included. The analysed data were pre-operative findings for venous insufficiency (CEAP - clinical, etiological, anatomical, physiopathologic - classification and venous ultrassonographic findings, type of surgery (open or laparoscopic, abdominal circumference, body mass index (BMI and post-operative ultrassonography search for venous insufficiency and deep venous thrombosis. Results Between March 2007 and December 2009, 95 patients candidates for bariatric surgery had clinical and duplex scan evaluation of the lower limbs venous system. Of the 95 patients, 53 were submitted to the surgical procedure. There was a predominance of women (77.9%, the average age was 38.5 years, average preoperative weight 124.6 kg and average BMI of 45.5 kg/m2. Regarding obesity, 16.8% were obese, and 83.1% were morbidly obese. In relation to the venous findings, 86.3% of the patients did fit CEAP classification less than 3 and 13.7% greater than or equal to 3. Among the post-operative complications, there were four cases of wound infection. Three patients developed post-operative distal venous thrombosis (7.5%, but no one had clinically manifested pulmonary embolism. Conclusion No relation between BMI, CEAP classification and venous ultrassonographic findings were found. Although

  8. INVESTMENT IN COCOA PRODUCTION IN NIGERIA: A COST AND RETURN ANALYSIS OF THREE COCOA PRODUCTION MANAGEMENT SYSTEMS IN THE CROSS RIVER STATE COCOA BELT

    OpenAIRE

    Moses NKANG, Nkang; Agom AJAH, Eucharia; Obi ABANG, Sylvanus; Orok EDET, Eyo

    2007-01-01

    The study examined costs and returns in cocoa production in Cross River State in the context of three identified management systems of cocoa production in the area, namely owner-managed, lease-managed and sharecrop managed systems, using a hundred and fifty randomly selected cocoa farmers. Results show that cocoa production is a profitable business irrespective of management system, since all of them had positive net present values (NPV) at 10% discount rate. The NPV for lease-managed farms i...

  9. Active Return-to-Center Control Based on Torque and Angle Sensors for Electric Power Steering Systems.

    Science.gov (United States)

    Du, Pan-Pan; Su, Hao; Tang, Gong-You

    2018-03-14

    This paper presents a complete control strategy of the active return-to-center (RTC) control for electric power steering (EPS) systems. We first establish the mathematical model of the EPS system and analyze the source and influence of the self-aligning torque (SAT). Second, based on the feedback signals of steering column torque and steering wheel angle, we give the trigger conditions of a state switch between the steering assist state and the RTC state. In order to avoid the sudden change of the output torque for the driving motor when the state switches frequently between the steering assist state and the RTC state, we design an undisturbed state switching logic algorithm. This state switching logic algorithm ensures that the output value of the RTC controller is set to an initial value and increases in given steps up to a maximum value after entering the RTC state, and the output value of the RTC controller will reduce in given steps down to zero when exiting the RTC state. This therefore ensures smooth switch control between the two states and improves the driver's steering feeling. Third, we design the RTC controller, which depends upon the feedback signals of the steering wheel angle and the angular velocity. In addition, the controller increases the auxiliary control function of the RTC torque based on vehicle speed. The experimental results show that the active RTC control method does not affect the basic assist characteristics, which effectively reduces the residual angle of the steering wheel at low vehicle speed and improves the RTC performance of the vehicle.

  10. Active Return-to-Center Control Based on Torque and Angle Sensors for Electric Power Steering Systems

    Directory of Open Access Journals (Sweden)

    Pan-Pan Du

    2018-03-01

    Full Text Available This paper presents a complete control strategy of the active return-to-center (RTC control for electric power steering (EPS systems. We first establish the mathematical model of the EPS system and analyze the source and influence of the self-aligning torque (SAT. Second, based on the feedback signals of steering column torque and steering wheel angle, we give the trigger conditions of a state switch between the steering assist state and the RTC state. In order to avoid the sudden change of the output torque for the driving motor when the state switches frequently between the steering assist state and the RTC state, we design an undisturbed state switching logic algorithm. This state switching logic algorithm ensures that the output value of the RTC controller is set to an initial value and increases in given steps up to a maximum value after entering the RTC state, and the output value of the RTC controller will reduce in given steps down to zero when exiting the RTC state. This therefore ensures smooth switch control between the two states and improves the driver’s steering feeling. Third, we design the RTC controller, which depends upon the feedback signals of the steering wheel angle and the angular velocity. In addition, the controller increases the auxiliary control function of the RTC torque based on vehicle speed. The experimental results show that the active RTC control method does not affect the basic assist characteristics, which effectively reduces the residual angle of the steering wheel at low vehicle speed and improves the RTC performance of the vehicle.

  11. New MRI muscle classification systems and associations with return to sport after acute hamstring injuries: a prospective study.

    Science.gov (United States)

    Wangensteen, Arnlaug; Guermazi, Ali; Tol, Johannes L; Roemer, Frank W; Hamilton, Bruce; Alonso, Juan-Manuel; Whiteley, Rodney; Bahr, Roald

    2018-02-19

    To determine agreement between modified Peetrons, Chan acute muscle strain injury classification and British Athletics Muscle Injury Classification (BAMIC) and to investigate their associations and ability to predict time to return to sport (RTS). Male athletes (n=176) with acute hamstring injury and MRI (1.5T) ≤5 days were followed until RTS. MRIs were scored using standardised forms. For MRI-positive injuries there was moderate agreement in severity grading (κ = 0.50-0.56). Substantial variance in RTS was demonstrated within and between MRI categories. Mean differences showed an overall main effect for severity grading (p < 0.001), but post hoc pairwise comparisons for BAMIC (grade 0a/b vs. 1, p = 0.312; 1 vs 2, p = 0.054; 0a/b vs 2, p < 0.001; 1 vs 3, p < 0.001) and mean differences for anatomical sites (BAMIC a-c, p < 0.001 [a vs b, p = 0.974; a vs c, p = 0.065; b vs c, p = 0.007]; Chan anatomical sites 1-5, p < 0.077; 2A-C, p = 0.373; 2a-e, p = 0.008; combined BAMIC, p < 0.001) varied. For MRI-positive injuries, total explained RTS variance was 7.6-11.9% for severity grading and BAMIC anatomical sites. There was wide overlap between/variation within the grading/classification categories. Therefore, none of the classification systems could be used to predict RTS in our sample of MRI-positive hamstring injuries. • Days to RTS varied greatly within the grading and classification categories. • Days to RTS varied greatly between the grading and classification categories. • Using MRI classification systems alone to predict RTS cannot be recommended. • The specific MRI classification used should be reported to avoid miscommunication.

  12. Usefulness of the Guglielmi detachable coil for embolization of a systemic venous collateral after Fontan operation: A case report.

    Science.gov (United States)

    Sonomura, Tetsuo; Ikoma, Akira; Kawai, Nobuyuki; Suenaga, Tomohiro; Takeuchi, Takashi; Suzuki, Hiroyuki; Uchita, Shunji; Nakai, Motoki; Minamiguchi, Hiroki; Kishi, Kazushi; Sato, Morio

    2012-09-28

    Embolization of collateral veins is often treated with rigid coils (Gianturco and interlocking detachable coils type). However, when dealing with tortuous and dilated collateral veins, there is a high risk for technical failure and coil migration due to inflexibility of the coils. To safely and successfully solve this problem, Guglielmi detachable coils (GDC) can be used for embolization. Their flexibility allows for easy navigation in tortuous veins, low risk of unintended coil release or coil migration, and safe deployment. A 12-year-old girl with a single ventricle had severe cyanosis and a low exercise tolerance 5 years after Fontan procedure. The symptoms were caused by a tortuous and dilated collateral from the left phrenic vein into the left pulmonary vein, forming a right-to-left shunt. The collateral, which had a large diameter and high flow, and therefore a high risk of coil migration, was successfully embolized with 8 GDC. There were no complications such as coil migration or cerebral infarction. Transcatheter embolization increased her systemic oxygen saturation from 81%-84% to 94%-95%, and increased her ability to exercise. The embolization procedure using flexible GDC was low risk compared with other rigid coil embolization techniques when performing embolization of tortuous and dilated collateral veins.

  13. A failure of preoperative duplex imaging to diagnose a lower extremity venous aneurysm in a patient with severe chronic venous insufficiency

    Directory of Open Access Journals (Sweden)

    Roy Wesley Jones

    2017-02-01

    Full Text Available Objective: We present a case of recurrent bilateral lower extremity venous stasis ulcers in association with a superficial venous aneurysm at the right saphenofemoral junction that was misdiagnosed on preoperative duplex scanning. Methods: A 53-year-old female presented to our clinic with 6-year history of bilateral lower extremity venous stasis ulcers. Her past medical history was significant for refractory venous stasis ulcers of the bilateral lower extremities present for 6 years and morbid obesity. Results: Preoperative venous duplex demonstrated severe venous insufficiency of the superficial and deep systems, but a venous aneurysm was not appreciated. During the high ligation of the right saphenofemoral junction, a 3 × 4 × 5 cm aneurysm was encountered. Repair consisted of aneurysm resection, high ligation of the greater saphenous vein, dissociation of the great saphenous and anterior saphenous veins, and stab phlebectomy of large varicose veins of the thigh and lower leg. The patient recovered uneventfully and experienced complete healing of the venous stasis ulcer in several weeks. Conclusion: Superficial venous aneurysms of the lower extremity are rare and can be often missed on preoperative duplex ultrasound imaging. Large diameter measurements of the proximal greater saphenous vein and obesity increase the risk of misdiagnosing venous aneurysms with duplex imaging; therefore, clinical suspicion must remain high. These aneurysms can be associated with significant symptoms for which repair is indicated.

  14. Fluid flow along venous adventitia in rabbits: is it a potential drainage system complementary to vascular circulations?

    Directory of Open Access Journals (Sweden)

    Hong-yi Li

    Full Text Available BACKGROUND: Our previous research and other studies with radiotracers showed evidence of a centripetal drainage pathway, separate from blood or lymphatic vessels, that can be visualized when a small amount of low molecular weight tracer is injected subcutaneously into a given region on skin of humans. In order to further characterize this interesting biological phenomenon, animal experiments are designed to elucidate histological and physiologic characteristics of these visualized pathways. METHODS: Multiple tracers are injected subcutaneously into an acupuncture point of KI3 to visualize centripetal pathways by magnetic resonance imaging or fluorescein photography in 85 healthy rabbits. The pathways are compared with venography and indirect lymphangiography. Fluid flow through the pathways is observed by methods of altering their hydrated state, hydrolyzing by different collagenases, and histology is elucidated by optical, fluorescein and electron microscopy. RESULTS: Histological and magnetic imaging examinations of these visualized pathways show they consist of perivenous loose connective tissues. As evidenced by examinations of tracers' uptake, they appear to function as a draining pathway for free interstitial fluid. Fluorescein sodium from KI3 is found in the pathways of hind limbs and segments of the small intestines, partial pulmonary veins and results in pericardial effusion, suggesting systematical involvement of this perivenous pathway. The hydraulic conductivity of these pathways can be compromised by the collapse of their fiber-rich beds hydrolyzed by either of collagenase type I, III, IV or V. CONCLUSIONS: The identification of pathways comprising perivenous loose connective tissues with a high hydraulic conductivity draining interstitial fluid in hind limbs of a mammal suggests a potential drainage system complementary to vascular circulations. These findings may provide new insights into a systematically distributed collagenous

  15. Anatomic variation of the deep venous system and its relationship with deep vein thrombosis found on the lower extremity venograms that were obtained after artificial joint replacements

    International Nuclear Information System (INIS)

    Lee, Min Sun; Lee, Jee Eun; Hwang, Ji Young; Shim, Sung Shine; Yoo, Jeong Hyun; Suh, Jeong Soo; Park, Jae Young

    2006-01-01

    artificial joint replacements. The total number of asymptomatic DVT cases was 43 (23.1%) and DVT was found in the calf in 39 of these cases. Post-operative venograms of the lower extremity showed 7 types of anatomic variation in the deep venous system. The incidence of silent post-operative DVT was not influenced by anatomic variations of the deep vein system, whether there were a small or large number of valves and the operation sites for artificial joint replacement. The most frequent site of DVT after artificial joint replacement was the calf

  16. Anatomic variation of the deep venous system and its relationship with deep vein thrombosis found on the lower extremity venograms that were obtained after artificial joint replacements

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Sun; Lee, Jee Eun; Hwang, Ji Young; Shim, Sung Shine; Yoo, Jeong Hyun; Suh, Jeong Soo; Park, Jae Young [College of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2006-11-15

    artificial joint replacements. The total number of asymptomatic DVT cases was 43 (23.1%) and DVT was found in the calf in 39 of these cases. Post-operative venograms of the lower extremity showed 7 types of anatomic variation in the deep venous system. The incidence of silent post-operative DVT was not influenced by anatomic variations of the deep vein system, whether there were a small or large number of valves and the operation sites for artificial joint replacement. The most frequent site of DVT after artificial joint replacement was the calf.

  17. Nontraumatic vascular emergencies: imaging and intervention in acute venous occlusion

    International Nuclear Information System (INIS)

    Haage, Patrick; Schmitz-Rode, Thomas; Krings, Timo

    2002-01-01

    Risk factors for acute venous occlusion range from prolonged immobilization to hypercoagulability syndromes, trauma, and malignancy. The aim of this review article is to illustrate the different imaging options for the diagnosis of acute venous occlusion and to assess the value of interventional strategies for venous thrombosis treatment in an emergency setting. First, diagnosis and treatment of the most common form of venous occlusion, at the level of the lower extremities, is presented, followed by pelvic vein and inferior vena cava occlusion, mesenteric venous thrombosis, upper extremity occlusion, acute cerebral vein thrombosis, and finally acute venous occlusion of hemodialysis access. In acute venous occlusion of the lower extremity phlebography is still the reference gold standard. Presently, duplex ultrasound with manual compression is the most sensitive and specific noninvasive test. Limitations of ultrasonography include isolated distal calf vein occlusion, obesity, and patients with lower extremity edema. If sonography is nondiagnostic, venography should be considered. Magnetic resonance venography can differentiate an acute occlusion from chronic thrombus, but because of its high cost and limited availability, it is not yet used for the routine diagnosis of lower extremity venous occlusion only. Regarding interventional treatment, catheter-directed thrombolysis can be applied to dissolve thrombus in charily selected patients with symptomatic occlusion and no contraindications to therapy. Acute occlusion of the pelvic veins and the inferior vena cava, often due to extension from the femoropopliteal system, represents a major risk for pulmonary embolism. Color flow Doppler imaging is often limited owing to obesity and bowel gas. Venography has long been considered the gold standard for identifying proximal venous occlusion. Both CT scanning and MR imaging, however, can even more accurately diagnose acute pelvis vein or inferior vena cava occlusion. MRI is

  18. Nontraumatic vascular emergencies: imaging and intervention in acute venous occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Haage, Patrick; Schmitz-Rode, Thomas [Department of Diagnostic Radiology, University of Technology Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krings, Timo [Department of Neuroradiology, University of Technology Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2002-11-01

    Risk factors for acute venous occlusion range from prolonged immobilization to hypercoagulability syndromes, trauma, and malignancy. The aim of this review article is to illustrate the different imaging options for the diagnosis of acute venous occlusion and to assess the value of interventional strategies for venous thrombosis treatment in an emergency setting. First, diagnosis and treatment of the most common form of venous occlusion, at the level of the lower extremities, is presented, followed by pelvic vein and inferior vena cava occlusion, mesenteric venous thrombosis, upper extremity occlusion, acute cerebral vein thrombosis, and finally acute venous occlusion of hemodialysis access. In acute venous occlusion of the lower extremity phlebography is still the reference gold standard. Presently, duplex ultrasound with manual compression is the most sensitive and specific noninvasive test. Limitations of ultrasonography include isolated distal calf vein occlusion, obesity, and patients with lower extremity edema. If sonography is nondiagnostic, venography should be considered. Magnetic resonance venography can differentiate an acute occlusion from chronic thrombus, but because of its high cost and limited availability, it is not yet used for the routine diagnosis of lower extremity venous occlusion only. Regarding interventional treatment, catheter-directed thrombolysis can be applied to dissolve thrombus in charily selected patients with symptomatic occlusion and no contraindications to therapy. Acute occlusion of the pelvic veins and the inferior vena cava, often due to extension from the femoropopliteal system, represents a major risk for pulmonary embolism. Color flow Doppler imaging is often limited owing to obesity and bowel gas. Venography has long been considered the gold standard for identifying proximal venous occlusion. Both CT scanning and MR imaging, however, can even more accurately diagnose acute pelvis vein or inferior vena cava occlusion. MRI is

  19. Venous and Arterial Thromboses: Two Sides of the Same Coin?

    Science.gov (United States)

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-04-01

    Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical

  20. Influence of sulfur dioxide on the respiratory system of Miyakejima adult residents 6 years after returning to the island.

    Science.gov (United States)

    Kochi, Takeshi; Iwasawa, Satoko; Nakano, Makiko; Tsuboi, Tazuru; Tanaka, Shigeru; Kitamura, Hiroko; Wilson, Donald John; Takebayashi, Toru; Omae, Kazuyuki

    2017-07-27

    Mount Oyama, on the Japanese island of Miyakejima, began erupting in June 2000, necessitating the evacuation of 3,000 island residents. Volcanic gas emissions, primarily consisting of sulfur dioxide (SO 2 ), gradually decreased and residents returned to the island after the evacuation order was lifted in February 2005. To assess the exposure-effect and exposure-response relationships between SO 2 exposure and effects on respiratory system in adult Miyakejima residents. Health checkups focusing on pulmonary function and respiratory/irritative symptoms were conducted six times every November from 2006 to 2011. The study population comprised 168 subjects who underwent all health checkups. SO 2 concentrations were measured at six fixed monitoring stations in inhabitable areas. Based on the annual mean SO 2 concentration, inhabitable areas were classified into three categories; namely, lower (L), higher (H-1), and highest (H-2) areas. Average SO 2 concentrations (ppb) during 3 months prior to each health checkup dropped from 11.3 to 3.29, 32.2 to 13.4 and 75.1 to 12.6 from 2006 to 2010/2011 in L, H-1, and H-2. No significant declines in pulmonary function were observed in all areas. However, prevalence of subjective symptoms such as "Cough," "Irritation and/or pain in throat," "Irritation, runny nose, and/or nasal sniffles," and "Irritation and/or pain in the eyes," dependently increased on SO 2 concentration. Odds ratios were statistically significant at approximately 70 ppb of SO 2 or above. Adult residents of Miyakejima island showed no deterioration in pulmonary function at SO 2 levels, but complained of respiratory/irritative symptoms in an SO 2 concentration-dependent manner.

  1. The return, devolution and deposit systems (RDDS), what do they involve?; Los sistemas de deposito devolucion y retorno (SDDR), Que implican?

    Energy Technology Data Exchange (ETDEWEB)

    Sanz de Siria Alvarez, L.

    2003-07-01

    The return, devolution and deposit systems (RDDS), what do they involve?. In this article, we try to clarify these doubts about SDDR (Return, Devolution and Deposit Systems) and show the differences between obligations regarding domestic packages and industrial ones. In addition to this, it is important to know if we are treating pure waste or a re-usable product. One of the most unknown features in the 11/97 Law of Packages and Remainders of Packages are the RDDS. This is because of the large number of obligations and the small area of action that they have. Because of that, application of this system is practically null as an alternative to the integrated management systems (IMS). (Author)

  2. Epidemiology of recurrent venous thrombosis

    Science.gov (United States)

    Ribeiro, D.D.; Lijfering, W.M.; Barreto, S.M.; Rosendaal, F.R.; Rezende, S.M.

    2011-01-01

    Venous thrombosis, including deep vein thrombosis and pulmonary embolism, is a common disease that frequently recurs. Recurrence can be prevented by anticoagulants, but this comes at the risk of bleeding. Therefore, assessment of the risk of recurrence is important to balance the risks and benefits of anticoagulant treatment. This review briefly outlines what is currently known about the epidemiology of recurrent venous thrombosis, and focuses in more detail on potential new risk factors for venous recurrence. The general implications of these findings in patient management are discussed. PMID:22183247

  3. Product Return Handling

    OpenAIRE

    de Brito, M.P.; de Koster, M.B.M.

    2003-01-01

    textabstractIn this article we focus on product return handling and warehousing issues. In some businesses return rates can be well over 20% and returns can be especially costly when not handled properly. In spite of this, many managers have handled returns extemporarily. The fact that quantitative methods barely exist to support return handling decisions adds to this. In this article we bridge those issues by 1) going over the key decisions related with return handling; 2) identifying quanti...

  4. Massive superior mesenteric venous aneurysm with portal venous thrombosis.

    Science.gov (United States)

    Starikov, Anna; Bartolotta, Roger J

    2015-01-01

    Portal venous aneurysm is a rare and sometimes dangerous vascular pathology, which can result in thrombosis or rupture. We present the computed tomography, magnetic resonance, and sonographic imaging of a 27-year-old man with superior mesenteric venous aneurysm and subsequent thrombosis following acute pancreatitis. This multimodality imaging approach can prove useful in the evaluation of these rare aneurysms. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Projeto de aterramento para sistema monofilar com retorno pelo terra Grounding project for single wire earth return system

    Directory of Open Access Journals (Sweden)

    Humberto C Bertolo

    2011-02-01

    Full Text Available Este trabalho apresenta o projeto de aterramento elétrico para Sistema Monofilar com Retorno pela Terra (MRT, em solicitações de baixas frequências, utilizando-se o método das imagens e considerando a simplificação do método dos potenciais constantes. Simulou-se o comportamento de três diferentes configurações de aterramento: hastes em triângulo, em quadrado vazio e para nove hastes, formando uma malha com quatro quadrados. A partir da simulação obtiveram-se o valor da resistência de aterramento para cada configuração e os potenciais gerados na superfície do solo. Com base nesses resultados foi possível comparar os valores tabelados para resistências mínimas, em função da potência do transformador, aplicados para diferentes concessionárias de energia que utilizam o Sistema MRT, com os valores calculados que mantêm os potenciais no solo em níveis seguros para seres humanos e animais. Os resultados mostraram que é possível utilizar aterramentos mais simples e mais baratos, pois os gradientes de tensões no solo se mantiveram em níveis seguros.This work presents a grounding project for a Single Wire Earth Return (SWER system in low frequency applications, through the use of the image method, a simplification of the constant potential method. The responses of three different grounding configurations were simulated: electrodes in triangular format, electrodes placed in the corners of a square and nine electrodes placed in the corners of a grid with four squares. With the mentioned simulation it was possible to calculate the ground resistance and the surface voltage of each configuration. Based on these results, it was possible to compare the values for minimal resistance, depending on the power of the transformer, applied to various power utilities that use the SWER system with the values that hold the potential in the soil at safe levels for human beings and animals. Results showed that it is possible to use simpler and

  6. Color-flow Doppler imaging in suspected extremity venous thrombosis

    International Nuclear Information System (INIS)

    Foley, W.D.; Middleton, W.D.; Lawson, T.L.; Hinson, G.W.; Puller, D.R.

    1987-01-01

    Color-flow Doppler imaging (CFDI) (Quanatum, 5 and 7.5 MHz, linear array) has been performed on 23 extremities (nine positive for venous thrombosis, 14 negative) with venographic correlation. CFDI criteria evaluated were venous color-flow respiratory variation, augmentation, compressibility, valve competence, and intraluminal echogenic filling defects. Both CFDI and venography were evaluated independently and prospectively. CFDI and venography agreed in all six cases of femoral vein thrombosis and eight of nine cases of popliteal vein thrombosis. CFDI was negative in one instance of recanalized popliteal vein thrombosis. Recanalized femoral vein thrombosis was documented in three patients by CFDI when the vein was nonopacified on conventional venography. CFDI provides a rapid and accurate assessment of the femoral popliteal venous system and can distinguish an occluded from a recanalized thrombus. Initial experience with auxiliary subclavian venous thrombus has produced equally accurate results

  7. Avaliação da pressão venosa periférica na esclerose sistêmica Peripheral venous pressure in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    João Potério-Filho

    2004-02-01

    Full Text Available OBJETIVO: Estabelecer a utilidade da medida indireta da pressão venosa periférica (PVP na avaliação de pacientes com esclerose sistêmica (ES, comparando com uma população controle normal. MÉTODOS: Estudo prospectivo avaliando 18 pacientes esclerodérmicas do sexo feminino (sendo oito delas com úlcera cutânea isquêmica submetidas à medida indireta da PVP (por pletismografia. Os dados foram comparados a um grupo controle normal de 18 mulheres hígidas, pareadas para idade. RESULTADOS: Os níveis de pressão arterial foram semelhantes nos dois grupos. Os valores de PVP estavam significativamente diminuídos nos pacientes com ES (58.9 ± 11.6 mmHg no grupo ES e 96.9 ± 7.1 mmHg no grupo controle; p OBJECTIVE: The aim of this prospective study was to establish the usefulness of indirect measurement of peripheral venous pressure (PVP in the evaluation of patients with systemic sclerosis (SSc, comparing them with a normal control population. METHODS: Eighteen female SSc patients (eight patients presenting cutaneous ischemic ulcers were submitted to indirect measurement of the PVP (by plethysmography, and data were compared with a control group of 18 healthy women, paired by age. RESULTS: Arterial pressure levels were similar in both groups. PVP levels were significantly decreased in the SSc patients (58.9 ± 11.6 mmHg in the SSc group and 96.9 ± 7.1 mmHg in the control group; p < 0.0001; in the SSc group, patients with ischemic ulcers presented PVP levels significantly decreased compared with those patients without ulcers (50.6 ± 10.8 mmHg in the ulcer group and 65.5 ± 7.2 mmHg in the group without ulcers; p = 0.006. CONCLUSIONS: It can be concluded that decreased PVP in SSc is associated with a decrease in the blood flow of these patients, predisposing them to cutaneous ischemic ulcers.

  8. Product return management

    DEFF Research Database (Denmark)

    Shaharudin, Mohd Rizaimy; Govindan, Kannan; Zailani, Suhaiza

    2017-01-01

    The aim of this study is to examine the extent to which product returns motivate manufacturing firms to adopt closed-loop supply chain activities that influence the effectiveness of reverse supply chains. The hypotheses have been tested using data from a sample of 150 environmental management...... system ISO 14001 certified manufacturing firms in Malaysia through the census sampling approach. The results of the empirical test using LISREL Version 8.70 for the structural equation modeling support the fundamental explanation of the influence of the institutional forces towards the adoption of closed......-loop supply chain activities and the effectiveness that can be reaped by the manufacturing firms from their adoption. These findings extend the prior research through the verification from the empirical survey on the importance of product returns in the adoption of closed-loop supply chain activities, which...

  9. Lower extremity arterial and venous ulcers.

    Science.gov (United States)

    Sieggreen, Mary

    2005-06-01

    The prevalence of peripheral arterial disease in the general population is high, but the awareness of primary care providers of the disease process is low. The disease is not recognized by primary care providers. Early recognition and treatment of venous diseases that progress to postphlebotic syndrome, such as after a deep vein thrombosis, will prevent venous ulcers that add considerable expense to the health care system. Vascular assessment, including routine ABI measurement of patients who are in risk categories for vascular disease will identify those patients so that prevention programs can be put into place early. Major contributions to the understanding and management of leg ulcers and wound healing have been made in the last decade. However, there is still confusion as to the exact mechanism behind ulcer development and the best method to manage, cure,and prevent these ulcers has yet to be found.

  10. Mean systemic filling pressure : from Guyton to the ICU

    NARCIS (Netherlands)

    Maas, Jacomina Johanna (Jacinta)

    2013-01-01

    Mean systemic filling pressure (Pmsf)is defined as the pressure in the blood vessels during cardiac arrest. Pmsf is an important determinant for venous return to the heart and thus for cardiac output. This thesis describes a method to measure Pmsf at the bedside in intensive care patients and

  11. Hydrocephalus in cerebral venous thrombosis

    NARCIS (Netherlands)

    Zuurbier, Susanna M.; van den Berg, René; Troost, Dirk; Majoie, Charles B.; Stam, Jan; Coutinho, Jonathan M.

    2015-01-01

    Increased intracranial pressure is common in cerebral venous thrombosis (CVT), but hydrocephalus is rarely reported in these patients. We examined the frequency, pathophysiology and associated clinical manifestations of hydrocephalus in patients with CVT admitted to our hospital between 2000 and

  12. Another return to "Return to Equilibrium"

    CERN Document Server

    Fröhlich, J

    2003-01-01

    The property of ``return to equilibrium'' is established for a class of quantum-mechanical models describing interactions of a (toy) atom with black-body radiation, or of a spin with a heat bath of scalar bosons, under the assumption that the interaction strength is sufficiently weak, but independent of temperature $T$, (with $0system valid for all temperatures $T\\geq 0$, assuming only that the interaction strength is sufficiently weak.

  13. Congenital Retinal Macrovessel and the Association of Retinal Venous Malformations With Venous Malformations of the Brain.

    Science.gov (United States)

    Pichi, Francesco; Freund, K Bailey; Ciardella, Antonio; Morara, Mariachiara; Abboud, Emad B; Ghazi, Nicola; Dackiw, Christine; Choudhry, Netan; Souza, Eduardo Cunha; Cunha, Leonardo Provetti; Arevalo, J Fernando; Liu, T Y Alvin; Wenick, Adam; He, Lingmin; Villarreal, Guadalupe; Neri, Piergiorgio; Sarraf, David

    2018-04-01

    Congenital retinal macrovessel (CRM) is a rarely reported venous malformation of the retina that is associated with venous anomalies of the brain. To study the multimodal imaging findings of a series of eyes with congenital retinal macrovessel and describe the systemic associations. In this cross-sectional multicenter study, medical records were retrospectively reviewed from 7 different retina clinics worldwide over a 10-year period (2007-2017). Patients with CRM, defined as an abnormal, large, macular vessel with a vascular distribution above and below the horizontal raphe, were identified. Data were analyzed from December 2016 to August 2017. Clinical information and multimodal retinal imaging findings were collected and studied. Pertinent systemic information, including brain magnetic resonance imaging findings, was also noted if available. Of the 49 included patients, 32 (65%) were female, and the mean (SD) age at onset was 44.0 (20.9) years. A total of 49 eyes from 49 patients were studied. Macrovessel was unilateral in all patients. Color fundus photography illustrated a large aberrant dilated and tortuous retinal vein in all patients. Early-phase frames of fluorescein angiography further confirmed the venous nature of the macrovessel in 40 of 40 eyes. Optical coherence tomography angiography, available in 17 eyes (35%), displayed microvascular capillary abnormalities around the CRM, which were more evident in the deep capillary plexus. Of the 49 patients with CRM, 39 (80%) did not illustrate any evidence of ophthalmic complications. Ten patients (20%) presented with retinal complications, typically an incidental association with CRM. Twelve patients (24%) were noted to have venous malformations of the brain with associated magnetic resonance imaging. Of these, location of the venous anomaly in the brain was ipsilateral to the CRM in 10 patients (83%) and contralateral in 2 patients (17%), mainly located in the frontal lobe in 9 patients (75%). Our study has

  14. Diagnosis of venous disorders; A challenge for the radiologist. Die radiologische Diagnostik von Venenerkrankungen; Eine Herausforderung

    Energy Technology Data Exchange (ETDEWEB)

    Minar, E. (Abt. Angiologie, Universitaetsklinik fuer Innere Medizin 2, Vienna (Austria))

    1993-09-01

    Limited accuracy in the clinic diagnosis of deep vein thrombosis (VT) makes such diagnostic tests such as duplex sonography or venography necessary. Exact information on the age and extent of the thrombus are necessary for the clinician to optimize the therapeutric management. The correct diagnosis of calf vein thrombosis and of recurrent VT in patients with postphlebitis changes also has implications for treatment. After exclusion of thrombosis, the radiologist should evaluate the leg for other possible causes of symptoms besides VT. Investigation of the venous sytem also has a role in the diagnosis in patients with suspected pulmonary embolism. In patients with chronic venous insuffficiency the deep venous system should assessed for patency and venous valve function. The superficial veins should be differentiated in segments with sufficient or insufficient venous valves, and it is also necessary to look for insufficiency of the perforrating veins. In patients with superficial phlebitis there is risk of propagation into the deep venous system. (orig.)

  15. Product Return Handling

    NARCIS (Netherlands)

    M.P. de Brito (Marisa); M.B.M. de Koster (René)

    2003-01-01

    textabstractIn this article we focus on product return handling and warehousing issues. In some businesses return rates can be well over 20% and returns can be especially costly when not handled properly. In spite of this, many managers have handled returns extemporarily. The fact that quantitative

  16. Survey of European and Major ISC Facilities for Supporting Mars and Sample Return Mission Aerothermodynamics and Tests Required for Thermal Protection System and Dynamic Stability

    Directory of Open Access Journals (Sweden)

    Mathilde Bugel

    2011-01-01

    Full Text Available In the frame of future sample return missions to Mars, asteroids, and comets, investigated by the European Space Agency, a review of the actual aerodynamics and aerothermodynamics capabilities in Europe for Mars entry of large vehicles and high-speed Earth reentry of sample return capsule has been undertaken. Additionally, capabilities in Canada and Australia for the assessment of dynamic stability, as well as major facilities for hypersonic flows available in ISC, have been included. This paper provides an overview of European current capabilities for aerothermodynamics and testing of thermal protection systems. This assessment has allowed the identification of the needs in new facilities or upgrade of existing ground tests for covering experimentally Mars entries and Earth high-speed reentries as far as aerodynamics, aerothermodynamics, and thermal protection system testing are concerned.

  17. Energy return on investment (EROI) of mini-hydro and solar PV systems designed for a mini-grid

    OpenAIRE

    Kittner, N; Gheewala, SH; Kammen, DM

    2016-01-01

    © 2016 Elsevier Ltd With dramatic cost declines and performance improvements, both mini-hydropower and solar photovoltaics (PV) now serve as core options to meet the growing demand for electricity in underserved regions worldwide. We compare the net energy return on energy invested (EROI) of mini-hydropower and solar electricity using five existing mini-hydropower installations in northern Thailand with grid-connected solar PV simulations. Both assessments use a life cycle perspective to esti...

  18. Venous and autonomic function in formerly pre-eclamptic women and BMI-matched controls.

    Science.gov (United States)

    Heidema, Wieteke M; van Drongelen, Joris; Spaanderman, Marc E A; Scholten, Ralph R

    2018-03-25

    Pre-pregnancy reduced plasma volume increases the risk on subsequent pre-eclamptic pregnancy. Reduced plasma volume is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables and also relates to pre-eclampsia, increased body weight may underlie these observations. We hypothesized that the relationship between reduced venous reserve and preeclampsia is independent of body mass index (BMI). We compared the non-pregnant venous reserve capacity in 30 formerly pre-eclamptic women, equally divided in 3 BMI-classes (BMI 19.5-24.9, BMI 25-29.9, BMI ≥30) to 30 controls. Cases and controls were matched for BMI, age and parity. The venous reserve capacity was quantified by assessing plasma volume and venous compliance. The autonomic nervous system regulating the venous capacitance was evaluated with heart rate variability analysis in resting supine position and during positive head-up tilt (HUT). Formerly pre-eclamptic women had in supine position lower plasma volume than controls (1339 ± 79 vs 1547 ± 139 ml/m 2 (pBMI-matched controls, reduced venous reserve capacity. This is reflected by lower plasma volume and venous compliance, the autonomic balance is shifted towards sympathetic dominance and lower baroreceptor sensitivity. This suggests that not BMI, but underlying reduced venous reserve relates to pre-eclampsia. This article is protected by copyright. All rights reserved.

  19. Ethanol-Gel Sclerotherapy of Venous Malformations: Effectiveness and Safety.

    Science.gov (United States)

    Teusch, Veronika I; Wohlgemuth, Walter A; Hammer, Simone; Piehler, Armin P; Müller-Wille, René; Goessmann, Holger; Uller, Wibke

    2017-12-01

    In the treatment of venous malformations, ethanol may be administered in a gelified form to increase local effects and reduce systemic ones. The purpose of this prospective study was to evaluate the efficacy and safety of a commercially available viscous ethanol gel in the treatment of venous malformations. Thirty-one patients (mean age, 23.4 years; age range, 6.6-46.5 years) with venous malformations were prospectively scheduled for two ethanol-gel sclerotherapy sessions. Venous malformations were located at the lower extremity (n = 18), the upper extremity (n = 9), and the face (n = 4). Questionnaires to assess pain, clinical examinations, professional photographs, and contrast-enhanced MRI of the venous malformations were performed before and after therapy to measure therapy-induced changes. Two experienced radiologists blinded to the examination date and clinical status compared photographs and MR images before and after treatment. A mean of 4.2 mL of ethanol gel were administered per session. The technical success rate was 100%. Clinical success, defined as improvement or resolution of symptoms, was noted in 81% of patients. Mean pain score decreased, and the difference was statistically significant (3.9 vs 3.1, p = 0.005). In 54 treatment sessions where follow-up was available, four minor complications occurred. Comparison of photographs and MR images before and after treatment showed improvement in 35% and 93% of patients, respectively. Ethanol gel is an effective and safe sclerosing agent in the treatment of venous malformations.

  20. Combined oral contraceptives: venous thrombosis.

    Science.gov (United States)

    de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M

    2014-03-03

    Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene

  1. [Duplexsonography investigation in patients with venous ulcer].

    Science.gov (United States)

    Jeanneret-Gris, Christina

    2011-03-01

    Venous hypertension due to venous insufficiency causes venous ulcers. Duplexsonography is a widely accepted non invasive method to assess venous insufficiency with venous reflux measurements. Retrograde venous flow is defined as venous reflux. The testing of venous reflux is reliable if transvalvular pressure is sufficiently high and transvalvular flow velocity exceeds 30 cm/s. Reflux testing in the proximal leg veins (V. femoralis communis, V. femoralis, V. saphena magna) is done using a standardised Valsalva Manoeuvre (exspiration into a tube up to a pressure of 30 mmHg, pressure established within 0.5 seconds, pressure hold for 3 seconds). Distal leg vein testing (V. poplitea, V. tibialis posterior, V. saphena parva) is recommended with a two handed - compression distally to the tested veins. The most important parameter is venous reflux time, a cut off of > 2 seconds is recommended.

  2. LYMPHOVENOUS COMMUNICATIONS BETWEEN THE THORACIC DUCT AND THE AZYGOS VENOUS SYSTEM. Comunicaciones linfovenosas entre el conducto torácico y el sistema de la vena ácigos

    Directory of Open Access Journals (Sweden)

    Naief Dahran

    2016-03-01

    Full Text Available Las venas del tronco venoso de ácigos son altamente variables en lo que se refiere a orígenes, trayecto, afluentes y terminaciones. Las comunicaciones linfovenosas entre el conducto torácico y el sistema venoso de ácigos, fueron halladas en una disección de un cadáver embalsamado de 92 años de edad. El conducto linfático estaba dividido en dos pequeños vasos linfáticos los cuales, drenaban la vena hemiciácigos accesoria en los niveles de T9 y T8. Estas comunicaciones son clínicamente importantes debido a que pueden actuar como vías metastásicas desde la parte más inferior del cuerpo hasta los pulmones.  Veins of the azygos venous system are highly variable in terms of their origins, course, communications, tributaries and termination. Lymphovenous communic-ations between the thoracic duct and the azygos venous system were revealed during dissection of a 92-year-old female Thiel-embalmed cadaver. The thoracic duct branched into two small lymph vessels which drained into the accessory hemiazygos vein at the levels of T9 and T8. These communications are clinically important as they might act as metastatic pathways from the lower part of the body to the lungs

  3. Transjugular Intrahepatic Portosystemic Shunt for Maintenance of Portal Venous Patency in Liver Transplant Candidates

    Directory of Open Access Journals (Sweden)

    Ron Charles Gaba

    2013-01-01

    Full Text Available Maintenance of portal venous patency is vital to liver transplant candidates, as the presence of portal vein thrombosis (PVT adversely impacts clinical outcomes by increasing surgical complexity and decreasing postoperative survival. By enhancing portal venous blood flow, transjugular intrahepatic portosystemic shunt (TIPS creation may enable clearance of PVT and preservation of portal venous patency in cirrhotic patients. Herein, we describe four cases in which TIPS produced and sustained an open portal venous system in liver transplant candidates with partial PVT. All patients demonstrated rapid and effective flow-enabled clearance of clot and intermediate to long-term preservation of portal venous flow. On this basis, we propose that maintenance of portal venous patency in liver transplant candidates with partial PVT represents a developing indication for TIPS.

  4. The effect of ankle joint immobilization on lower limb venous flow.

    Science.gov (United States)

    Craik, Johnathan D; Clark, Amanda; Hendry, James; Sott, Andrea H; Hamilton, Paul D

    2015-01-01

    Below-knee cast immobilization is associated with an increased risk of developing deep vein thrombosis secondary to venous stasis. We investigated the effect of weight-bearing in a below-knee cast or pneumatic walking boot on lower limb venous blood flow. Duplex ultrasonography was used to measure venous blood flow in the popliteal vein of 10 healthy volunteers. Venous blood flow was measured while at rest, ambulating non-weight-bearing, partial weight-bearing, and full weight-bearing. Measurements were performed without ankle joint immobilization, with the ankle immobilized in a neutral cast, and with the ankle immobilized in a pneumatic walking boot in both neutral and equinus. There was no significant reduction in venous blood flow measurements between full weight-bearing without ankle joint immobilization and full weight-bearing in a neutral cast or neutral pneumatic walking boot. However, venous blood flow was reduced when partial weight-bearing (50%) and when full weight-bearing in a pneumatic walking boot in equinus. These results demonstrate that venous blood flow returned to normal levels when the subjects were permitted to fully bear weight in below-knee casts or walking boots, provided that the ankle joint was not in equinus. Weight-bearing status and ankle joint position should be appreciated during decisions for the provision of chemical thromboprophylaxis. © The Author(s) 2014.

  5. Superior mesenteric venous thrombosis treated by direct aspiration thrombectomy.

    Science.gov (United States)

    Nakayama, Satoshi; Murashima, Naoya; Isobe, Yoshinori

    2008-01-01

    A 69-year-old man, with hepatits C virus-related liver cirrhosis and hemophilia B, developed massive ascites and watery diarrhea after endoscopic injection sclerotherapy for esophageal varices. A multi detector row computed tomography revealed a superior mesenteric venous thrombus without bowel infarction. It was assumed that the thrombus was caused by transient congestion of the portal system after retrograde propagation of the sclerosant agent, in a condition where anticoagulation proteins, such as proteins C and S, had decreased. Because long systemic thrombolytic therapy was hazardous for the patient with hemorrhagic diathesis due to impaired coagulation, a direct thrombolysis was performed with urokinase followed by aspiration thrombectomy, with cannulation of the portal venous system using a transjugular intrahepatic approach. The patient had no complications in this procedure and subsequently diarrhea and refractory ascites were resolved. Direct thrombectomy via the transjugular intrahepatic route may be a useful therapy for mesenteric venous thrombus in the cirrhotic patient.

  6. Dutch Venous Ulcer guideline update.

    Science.gov (United States)

    Maessen-Visch, M Birgitte; de Roos, Kees-Peter

    2014-05-01

    The revised guideline of 2013 is an update of the 2005 guideline "venous leg ulcer". In this special project four separate guidelines (venous leg ulcer, varicose veins, compression therapy and deep venous disorders) were revised and developed simultaneously. A meeting was held including representatives of any organisation involved in venous disease management including patient organizations and health insurance companies. Eighteen clinical questions where defined, and a new strategy was used to accelerate the process. This resulted in two new and two revised guidelines within one year. The guideline committee advises use of the C of the CEAP classification as well as the Venous Clinical Severity Score (VCSS) and a Quality of life (QoL) score in the assessment of clinical signs. These can provide insight into the burden of disease and the effects of treatment as experienced by the patient. A duplex ultrasound should be performed in every patient to establish the underlying aetiology and to evaluate the need for treatment (which is discussed in a separate guideline). The use of the TIME model for describing venous ulcers is recommended. There is no evidence for antiseptic or antibiotic wound care products except for a Cochrane review in which some evidence is presented for cadexomer iodine. Signs of infection are the main reason for the use of oral antibiotics. When the ulcer fails to heal the use of oral aspirin and pentoxifylline can be considered as an adjunct. For the individual patient, the following aspects should be considered: the appearance of the ulcer (amount of exudate) according to the TIME model, the influence of wound care products on moisturising the wound, frequency of changing compression bandages, pain and allergies. The cost of the dressings should also be considered. Education and training of patients t improves compliance with compression therapy but does not influence wound healing rates. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Venous leg ulcer in the context of chronic venous disease.

    Science.gov (United States)

    Lozano Sánchez, F S; Marinel lo Roura, J; Carrasco Carrasco, E; González-Porras, J R; Escudero Rodríguez, J R; Sánchez Nevarez, I; Díaz Sánchez, S

    2014-05-01

    Chronic venous disease (CVD) is a frequent disorder with a high socioeconomic impact. Little is known about the possible differences between healed ulcer (C5 group) and active ulcer (C6 group) in terms of disease severity and quality of life (QoL). Our aim was to determine the possible differences in severity disease and QoL between the C5-C6 and C1 (control) group. Data from a national, multicentre, observational and cross-sectional study (n = 1598) were used to compare three groups of CVD: C1 (n = 243), C5 (n = 136) and C6 (n = 70). CVD severity was assessed with the Venous Clinical Severity Score (VCSS) and QoL with the Short Form 12 Health Survey (SF-12) and Chronic Lower Limb Venous Insufficiency Questionnaire (CIVIQ-20). Patients with active ulcers had a higher mean total VCSS than patients with healed ulcers (P ulcers than in those with C1 (P ulcers (C6) had lower QoL scores, but the differences were not statistically significant. Patients with venous leg ulcers (C5-C6) are associated with high severity and poor QoL. However, the healing of a leg ulcer did not contribute to improvement of QoL.

  8. Predictability of Stock Returns

    Directory of Open Access Journals (Sweden)

    Ahmet Sekreter

    2017-06-01

    Full Text Available Predictability of stock returns has been shown by empirical studies over time. This article collects the most important theories on forecasting stock returns and investigates the factors that affecting behavior of the stocks’ prices and the market as a whole. Estimation of the factors and the way of estimation are the key issues of predictability of stock returns.

  9. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    Science.gov (United States)

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  10. Step potential in single wire earth return system; Potencial de passo em sistema monofilar com retorno por terra

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Amancio R.; Caminha Junior, Isidoro C.; Watabe, Celso F.; Romero, Andrea G. [Mato Grosso do Sul Univ., Campo Grande, MS (Brazil). Dept. de Engenharia Eletrica

    1997-12-31

    It was built on the dependence of the campus of Mato Grosso do Sul University, an experimental line single wire earth return (SWER). It was realized, weekly, during the years of 1996, measurement of step potential, with a unique landing (primary only) and, primary and secondary connected. It was verified that: the most critical measurement happened when the earth presented superficial resistivity of 455,31 {Omega} x m, the highest step potential for not causing ventricular fibrillation was 249,93 V, needing a short circuit currents of 11,07 kA, the primary and secondary resistance earth presented values 42 {Omega} and 77 {Omega} respectively. There was no significant alteration when was used only the primary landing. (author) 11 refs., 2 figs.

  11. Laboratory evaluation of the limitations of positive pressure safety valves on hard-shell venous reservoirs.

    Science.gov (United States)

    Almany, Daniel K; Sistino, Joseph J

    2002-06-01

    Vacuum-assisted venous drainage (VAVD) is a technique used to increase venous return during cardiopulmonary bypass (CPB). However, VAVD has created some new safety concerns. One potential problem is the pressurization of the venous reservoir in the event of vacuum failure. To prevent this overpressurization, a positive pressure release valve (PPRV) is placed on the venous reservoir. The purpose of this study was to determine if there is a difference in the pressurization of venous reservoirs using various PPRVs. The method of this study included evaluation of four different venous reservoirs and their associated PPRVs. Each reservoir was completely sealed, and two roller pumps with 1/4-in tubing were connected to the reservoir suction inlet. The roller pumps were calibrated, and a disposable pressure transducer was used to measure pressure at the venous inlet. Each reservoir was first sealed and then pressurized to test the occlusion of the roller heads. The PPRVs were tested by measuring the venous inlet pressure at a range of suction flow rates from 0-5 L/min. Linear regression analysis was performed to predict the venous inlet pressure from the rate of suction flow for each PPRV. The PPRV in the Baxter, Gish, and Gambro reservoirs maintained a low reservoir pressure (40 mmHg) even at low flow rates (1-2 L/min). It is recommended that any reservoir used for VAVD be evaluated in a similar manner to determine whether it is safe under the maximal suction and vent flow conditions possible during clinical practice.

  12. Deep venous thrombosis and agenesis of the intrahepatic segment of inferior vena cava

    International Nuclear Information System (INIS)

    Velasco, J.; Fernandez, M.M.; Manzanares, R.; Hernando, A.

    1997-01-01

    We present a case of agenesis of the intrahepatic segment of inferior vena cava (IVC) with drainage through the azygos and hemiazygos systems. The presenting sign was deep venous thrombosis (DVT) in both lower extremities. The different imaging studies led to the diagnosis of both the congenital and acquired venous abnormalities, which are discussed. (Author) 14 refs

  13. Central venous catheter associated thrombosis of major veins: thrombolytic treatment with recombinant tissue plasminogen activator

    NARCIS (Netherlands)

    Rodenhuis, S.; van't Hek, L. G.; Vlasveld, L. T.; Kröger, R.; Dubbelman, R.; van Tol, R. G.

    1993-01-01

    Major thromboses can occur in the venous system in association with central venous catheters. This usually necessitates removal of the catheter. The effectiveness of low dose recombinant tissue type plasminogen activator (rt-PA) in combination with heparin was assessed in patients with central

  14. Why Returning to VET?

    Directory of Open Access Journals (Sweden)

    Erika Edith Gericke

    2017-11-01

    Full Text Available Educational choices, especially the influence of class on these choices have been a subject of lively international debate. However, thus far, there has been little international and comparative research with respect to vocational and education training (VET decision making from a subject-oriented perspective. This paper considers occupational-biographical orientations of English and German car mechatronics and focuses on the roles of learning and gaining vocational qualifications. Drawing on the concept of occupational-biographical orientations, the paper describes three types of orientations based on analyses of findings from 11 autobiographical-narrative interviews with English and German car mechatronics. The interviews clearly showed that occupational-biographical orientations explained different views on the necessity of returning to (continuous vocational education and training. They also demonstrated that subjective perceptions of the national VET system fostered particular occupational-biographical challenges, which supported or hindered existing learning attitudes. Overall, the findings suggested that occupational-biographical orientations exerted the most important influence on learning biographies and decisions to return to (continuous VET.

  15. Familial Clustering of Venous Thromboembolism

    DEFF Research Database (Denmark)

    Sindet-Pedersen, Caroline; Oestergaard, Louise Bruun; Gundlund, Anna

    2016-01-01

    BACKGROUND: Identification of risk factors for venous thromboembolism (VTE) is of utmost importance to improve current prophylactic regimes and treatment guidelines. The extent to which a family history contributes to the risk of VTE needs further exploration. OBJECTIVES: To examine the relative ...

  16. Lower-limb venous thrombosis

    African Journals Online (AJOL)

    muscle strains, tears, or twisting injuries to the leg. • other causes of lower-limb swelling such as cardiac, hepatic and renal pathologies. • lymphoedema. • chronic venous hypertension and its complications. • popliteal (Baker's) cysts. • cellulitis. • other knee pathologies. The objective methods of making a diagnosis of DVT ...

  17. Thromboembolic disorders: guidance for return-to-play.

    Science.gov (United States)

    Depenbrock, Patrick J

    2011-01-01

    Venous thromboembolism (VTE) is a major cause of morbidity and mortality. Treatment for VTE in athletes is similar to nonathletes. Early treatment of deep venous thrombosis (DVT) with bed rest and anticoagulation has given way to anticoagulation with early mobilization. Thrombolysis, preferably catheter-directed thrombolysis (CDT), may be used in select patients with upper extremity DVT (UEDVT). Surgical procedures should be reserved for those athletes with UEDVT who fail initial therapy. Compression devices are advocated for the treatment of postthrombotic symptoms (PTS) in lower extremity DVT (LEDVT) and UEDVT. Athletes with DVT should be encouraged to start a gradual return to activities of daily living (ADL) the day they begin anticoagulation therapy. A structured return-to-training program with progressive increase in intensity can begin shortly after ADL mastery, provided the athlete is monitored carefully for recurrence of VTE. Athletes should not engage in contact or collision sports until anticoagulation therapy is complete.

  18. Squamous cell carcinoma developed on chronic venous leg ulcer.

    Science.gov (United States)

    Sîrbi, Adelina Gabriela; Florea, Marius; Pătraşcu, Virgil; Rotaru, Maria; Mogoş, Dan Gabriel; Georgescu, Claudia Valentina; Mărgăritescu, Nicolae Dragoş

    2015-01-01

    Chronic venous leg ulcers (VLU), especially long-lasting non-healing ulcers, are among the risk factors for squamous cell carcinoma (SCC). Malignant transformation of a VLU is a rare finding and the relative risk of carcinomatous transformation is quite low (about 5.8). SCC arising in the context of a VLU has a particularly aggressive behavior. A 76-year-old male patient with no relevant medical familial history, with chronic venous insufficiency CEAP C6 for 10 years [recurrent leg ulcers with favorable outcome (healing) after specific local and systemic treatment], showing for about three years one ulcerated lesion located on the anterior upper third of the right calf non-responsive to specific treatment, which subsequently increased their size and merged. Biopsy sample was taken. Histopathology showed epidermal acanthosis, papillomatosis, intense parakeratosis, pseudoepitheliomatous hyperplasia, dysplasia and moderately differentiated squamous cell carcinoma with areas of acantholysis. Immunohistochemistry (Ki67, EMA, cytokeratin 34βE12 and p63) was performed and all types of immunostaining were moderately to intense positive. Above-knee leg amputation and specific oncologic treatment were proposed as possible curative solutions but the patient refused. Ten months after diagnosis and discharge form the Department of Dermatology, the patient died. Patients with chronic venous leg ulcers and clinically suspicious lesions should be evaluated for malignant transformation of the venous lesion. When diagnosed, malignancy complicating a chronic venous leg ulcer requires a resolute treatment as it may be fatal.

  19. Venous and arterial thrombosis: Two aspects of the same disease?

    Directory of Open Access Journals (Sweden)

    Paolo Prandoni

    2009-01-01

    Full Text Available Paolo PrandoniDepartment of Cardiothoracic and Vascular Sciences, Thromboembolism Unit, University Hospital of Padua Padua, ItalyAbstract: An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice.Keywords: venous thromboembolism, deep vein thrombosis, pulmonary embolism, myocardial infarction, ischemic stroke, atherosclerosis

  20. Proposal for the award of a contract for the supply of electronics for the temperature control of cavity windows and helium gas return lines for the superconducting cavities of the LEP200 radio frequency system

    CERN Document Server

    1991-01-01

    Proposal for the award of a contract for the supply of electronics for the temperature control of cavity windows and helium gas return lines for the superconducting cavities of the LEP200 radio frequency system

  1. An enlarged endocranial venous system in Steneosaurus pictaviensis (Crocodylia: Thalattosuchia) from the Upper Jurassic of LesLourdines, FranceUn système veineux endocrânien volumineux chez Steneosaurus pictaviensis (Crocodylia: Thalattosuchia) du Jurassique supérieur des Lourdines, France.

    Science.gov (United States)

    Wharton, Deborah Susan

    2000-08-01

    Large endocranial features are revealed in a three-dimensionally preserved specimen of the thalattosuchian crocodile Steneosaurus pictaviensis. Structures found on an endocast indicate the presence of the same venous blood system, although much enlarged, as found within the cranial cavity of modern crocodilians. An exceptionally large longitudinal dorsal blood sinus forms an expanded torcular herophili above the junction of the midbrain and hindbrain. The venous canals entering the posterodorsal part of the torcular herophili are the capiti dorsalis, which drain blood from the temporal and occipital musculature, entering the braincase in this region as in many extant and extinct Archosauria.

  2. Priority Science Targets for Future Sample Return Missions within the Solar System Out to the Year 2050

    Science.gov (United States)

    McCubbin, F. M.; Allton, J. H.; Barnes, J. J.; Boyce, J. W.; Burton, A. S.; Draper, D. S.; Evans, C. A.; Fries, M. D.; Jones, J. H.; Keller, L. P.; hide

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections: (1) Apollo samples, (2) LUNA samples, (3) Antarctic meteorites, (4) Cosmic dust particles, (5) Microparticle Impact Collection [formerly called Space Exposed Hardware], (6) Genesis solar wind, (7) Star-dust comet Wild-2 particles, (8) Stardust interstellar particles, and (9) Hayabusa asteroid Itokawa particles. In addition, the next missions bringing carbonaceous asteroid samples to JSC are Hayabusa 2/ asteroid Ryugu and OSIRIS-Rex/ asteroid Bennu, in 2021 and 2023, respectively. The Hayabusa 2 samples are provided as part of an international agreement with JAXA. The NASA Curation Office plans for the requirements of future collections in an "Advanced Curation" program. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. Here we review the science value and sample curation needs of some potential targets for sample return missions over the next 35 years.

  3. Universal modeling of weak antilocalization corrections in quasi-two-dimensional electron systems using predetermined return orbitals

    Science.gov (United States)

    Sawada, A.; Koga, T.

    2017-02-01

    We have developed a method to calculate the weak localization and antilocalization corrections based on the real-space simulation, where we provide 147 885 predetermined return orbitals of quasi-two-dimensional electrons with up to 5000 scattering events that are repeatedly used. Our model subsumes that of Golub [L. E. Golub, Phys. Rev. B 71, 235310 (2005), 10.1103/PhysRevB.71.235310] when the Rashba spin-orbit interaction (SOI) is assumed. Our computation is very simple, fast, and versatile, where the numerical results, obtained all at once, cover wide ranges of the magnetic field under various one-electron interactions H' exactly. Thus, it has straightforward extensibility to incorporate interactions other than the Rashba SOI, such as the linear and cubic Dresselhaus SOIs, Zeeman effect, and even interactions relevant to the valley and pseudo spin degrees of freedom, which should provide a unique tool to study new classes of materials like emerging 2D materials. Using our computation, we also demonstrate the robustness of a persistent spin helix state against the cubic Dresselhaus SOI.

  4. High capacity cask (TN28V) and International Transport System for the return shipment of vitrified high activity wastes

    International Nuclear Information System (INIS)

    Sert, G.; Savornin, B.; Rouquette, Y.

    1989-01-01

    The reprocessing of spent fuel generates different kinds of wastes. Among them fission products and non fissile actinides represent 98% of the radioactivity; these wastes are separated, concentrated, mixed with molten glass and poured into stainless steel containers. For political reasons, it is necessary to return these vitrified high activity wastes to the foreign countries which have decided to have their spent fuel reprocessed in France. So the transport of vitrified waste is vital for both the reprocessor and the utilities that have trusted the reprocessor and this operation has to be securely performed to give satisfaction to all concerned particles. For that reason Cogema will control the whole transport activity from La Hague plants to the receiving facilities of the customers. Therefore cogema will be responsible of the transport whatever the cask type (transport or storage) and will subcontract the transport operation to experienced companies such as Transnucleaire, PNTL or NTL, who will act on behalf of Cogema. Cogema will be the owner of the transport casks while the storage casks will normally be owned by the customers. Both cask types will of course have to comply with the requirements of La Hague, as published by Cogema

  5. The dynamics of health and return migration.

    Directory of Open Access Journals (Sweden)

    Anita A Davies

    2011-06-01

    Full Text Available The increasing importance and complexity of migration globally also implies a global increase in return migration, and thus an increased interest in the health of returning migrants. The health of returning migrants is impacted by the cumulative exposure to social determinants and risk factors of health during the migration process, during the return movement, and following return. Circular migration often occurs among the diaspora, which can result in the transfer of knowledge and skills that contribute to development, including health system strengthening. Migrants with dual nationality often return to countries with better health services than their country of origin when they are sick and can not get care at home. To maintain and improve the health of returning migrants, multi-sectoral policies at global and national levels should facilitate access to appropriate and equitable health services, social services, and continuity of care across and within borders.

  6. [An update on the treatment of venous insufficiency in pregnancy].

    Science.gov (United States)

    Rodríguez-Nora, B; Álvarez-Silvares, E

    2017-12-14

    Chronic venous insufficiency is a long-term pathological condition resulting from anatomical or functional alterations of the venous system. This leads to the appearance of symptoms and physical signs that affect a large part of the population and particularly pregnant women, due to the physiology of pregnancy. The few published studies on the use of pharmacological treatments of venous insufficiency in this group of the population, often makes the management of this condition difficult in routine clinical practice. A review is presented in this article, with all the latest updates in the treatment of this condition during pregnancy. There are numerous general, and some pharmacological, recommendations, that we can safely offer the pregnant patient. Copyright © 2017 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Venous Thoracic Outlet Syndrome: The Role of Early Rib Resection.

    Science.gov (United States)

    Katana, Vienna G; Weiss, Jeffrey S

    2016-11-01

    The upper extremity is an uncommon site for deep vein thrombosis and, although most of these thrombotic events are secondary to catheters or indwelling devices, venous thoracic outlet syndrome is an important cause of primary thrombosis. Young, active, otherwise healthy individuals that engage in repetitive upper extremity exercises, such as those required by a military vocation, may be at an increased risk. We present the case of a Naval Officer diagnosed with venous thoracic outlet syndrome whereby a multimodal approach with early surgical decompression was used. Although thoracic outlet decompression by means of first rib resection is the standard of care, timing of first rib resection after thrombolysis is debated. With respect to the active duty service member, the optimal timing of additional postoperative interventions for residual venous defects and duration of anticoagulation remain in question. A more streamlined perioperative treatment regimen may benefit the military patient without jeopardizing the quality of care and allow more expeditious return to full duty. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  8. Predictable return distributions

    DEFF Research Database (Denmark)

    Pedersen, Thomas Quistgaard

    This paper provides detailed insights into predictability of the entire stock and bond return distribution through the use of quantile regression. This allows us to examine speci…c parts of the return distribution such as the tails or the center, and for a suf…ciently …ne grid of quantiles we can...... trace out the entire distribution. A univariate quantile regression model is used to examine stock and bond return distributions individually, while a multivariate model is used to capture their joint distribution. An empirical analysis on US data shows that certain parts of the return distributions...... are predictable as a function of economic state variables. The results are, however, very different for stocks and bonds. The state variables primarily predict only location shifts in the stock return distribution, while they also predict changes in higher-order moments in the bond return distribution. Out...

  9. Cerebral Blood and CSF Flow Patterns in Patients Diagnosed for Cerebral Venous Thrombosis - An Observational Study

    Directory of Open Access Journals (Sweden)

    Souraya ElSankari

    2012-01-01

    Full Text Available Background and Purpose: Recent studies of the organization of the cerebral venous system in healthy subjects using phase contrast magnetic resonance imaging (PC-MRI show its structural complexity and inter-individual variations. Our objective was to study the venous blood and CSF flows in cerebral venous thrombosis (CVT. Materials and Methods: PC-MRI sequences were added to brain MRI conventional protocol in 19 patients suspected of CVT, among whom 6 patients had CVT diagnosis confirmed by MR venography. Results were compared with 18 healthy age-matched volunteers (HV. Results: In patients without CVT (NoCVT confirmed by venography, we found heterogeneous individual venous flows, and variable side dominance in paired veins and sinuses, comparable to those in healthy volunteers. In CVT patients, PC-MRI detected no venous flow in the veins and/or sinuses with thrombosis. Arterial flows were preserved. CSF aqueductal and cervical stroke volumes were increased in a patient with secondary cerebral infarction, and decreased in 4 patients with extended thrombosis in the superior sagittal and transverse sinuses. These results suggest the main role of the venous system in the regulation of the dynamic intracranial equilibrium. Conclusions: CVT produces highly individualized pattern of disturbance in venous blood drainage. Complementary to MRI venography, PC-MRI provides non-invasive data about venous blockage consequences on CSF flow disturbances.

  10. Drenagem venosa assistida através da utilização controlada de vácuo no reservatório venoso do oxigenador Assisted venous drainage using an adjustable vacuum system: a clinical study

    Directory of Open Access Journals (Sweden)

    Luiz Fernando CANÊO

    1999-04-01

    Full Text Available Nas operações minimamente invasivas o uso de cânula de menor calibre facilita a realização dos procedimentos cirúrgicos, mas, por outro lado, a drenagem venosa pode ser prejudicada. O emprego de vácuo no reservatório venoso do oxigenador é uma maneira simples e de baixo custo na correção do problema. O objetivo deste trabalho é apresentar nossa experiência com um dispositivo que permite além da utilização do vácuo, a sua regulagem conforme a necessidade específica do paciente e cânula empregada. Esse dispositivo consiste de uma válvula reguladora de vácuo, um filtro para a retenção de líquidos do ar aspirado e um manômetro eletrônico de pressão negativa. Os testes de bancada evidenciaram eficiência e segurança na aplicação da pressão negativa no oxigenador até 250 mmHg em temperaturas de até 40oC. O estudo clínico consistiu, inicialmente, na aplicação em 11 pacientes com esternotomia total. Posteriormente, foi utilizado em esternotomias parciais para tratamento da doença isolada da valva aórtica em 5 casos (L invertido e 4 casos de atriosseptoplastia. Esse dispositivo permitiu a utilização de cânulas de diâmetros menores que as cânulas únicas convencionais, variando de 32 a 26 Fr, com a utilização de pressões negativas de 62,40 ± 11,69 mmHg com drenagem venosa satisfatória, sem evidências indiretas de hemólise. O dispositivo por nós idealizado permitiu a drenagem venosa assistida com a utilização de vácuo de forma controlada, segura e eficiente.The use of small cannulae improves surgical field visualization in minimally invasive cardiac surgery, but may compromise the venous drainage. Vacuum assisted venous drainage is a simple and nonexpensive solution to this problem. We report our clinical experience using a device consisting of a negative pressure regulator, a vacuum line filter and an electronic manometer. The safety and efficacy of this CPB system was first tested in vitro, applying a

  11. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  12. Venous sinus stenting for pseudotumour cerebri with venous sinus stenosis

    International Nuclear Information System (INIS)

    Chen Huairui; Bai Rulin; Wu Xiaojun; Qi Xiangqian; Mei Qiyong; Lu Yicheng

    2011-01-01

    Objective: To explore the relation between venous sinus stenosis and pseduotumour cerebri and to discuss the efficacy and strategy of venous sinus stenting for its treatment. Methods: Venous sinus stenting was performed in a total of 9 patients with pseudotumour cerebri accompanied by dural sinus stenosis. The clinical data, including the clinical presentations, intracranial pressure, angiographic findings, pressure of dural sinus,methods of treatment and the therapeutic results, were retrospectively analyzed. Results: Bilateral disc edema was seen in all patients. The pressure gradient in the lateral sinuses was obviously high before stenting (22.67±7.25)mmHg in all patients and a reduction in intra-sinus pressure and pressure gradient was also found (5.78±3.77)mmHg. The symptoms associated with intracranial hypertension were gradually improved or disappeared in two weeks after the placement of the stent in all cases, and the intracranial pressure dropped evidently (12.78±5.97)cm H 2 O. Vision was improved in 7 cases at three months, whereas it remained poor in 2 cases despite normalized intracranial pressure. There was no other permanent procedure-related morbidity. The patients were followed up for 3 months to 5 years, and no recurrence developed. Conclusion: Lateral sinus stenting is an effective method for the treatment of pseudotumour cerebri with dural sinus stenosis. (authors)

  13. Classifying Returns as Extreme

    DEFF Research Database (Denmark)

    Christiansen, Charlotte

    2014-01-01

    I consider extreme returns for the stock and bond markets of 14 EU countries using two classification schemes: One, the univariate classification scheme from the previous literature that classifies extreme returns for each market separately, and two, a novel multivariate classification scheme...... that classifies extreme returns for several markets jointly. The new classification scheme holds about the same information as the old one, while demanding a shorter sample period. The new classification scheme is useful....

  14. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Science.gov (United States)

    2010-04-01

    ... activated one-way valve. The catheter is implanted with one end in the peritoneal cavity and the other in a large vein. This device enables ascitic fluid in the peritoneal cavity to flow into the venous system for the treatment of intractable ascites. (b) Classification. Class II. The special controls for this...

  15. Fibrinolysis and the risk of venous and arterial thrombosis

    NARCIS (Netherlands)

    Meltzer, Mirjam E.; Doggen, Catharina Jacoba Maria; de Groot, Philip G.; Rosendaal, Frits R.; Lisman, Ton

    2007-01-01

    Purpose of review: The fibrinolytic system is often regarded as just an innocent bystander in the pathogenesis of venous and arterial thrombosis, while (hyper)coagulation as a risk factor has been studied extensively. In this review, we evaluated studies that investigated the association between

  16. Validating the utilisation of venous bicarbonate as a predictor of ...

    African Journals Online (AJOL)

    Background. Crush injury secondary to sjambok beatings is a well-described phenomenon in southern Africa. Owing to a number of factors, it can result in acute kidney injury (AKI). In 1992, Muckart et al. described a risk stratification system using venous bicarbonate (VB) that can be used in the management of these ...

  17. [The contribution of Doppler echography in the diagnostic and therapeutic plan in chronic venous insufficiency surgery].

    Science.gov (United States)

    Perrin, M

    1993-01-01

    Indications for duplex scan in venous surgery. Vascular surgeons are led to request Duplex Scan examination of patients with chronic venous insufficiency in a number of circumstances: A) To obtain information supporting the diagnosis and treatment plan: Chronic venous insufficiency may be due to isolated superficial venous insufficiency or (and) deep venous insufficiency (post-thrombotic syndrome, primary deep valvular insufficiency, congenital malformation). In practice, Duplex Scan examination of the deep venous system is indicated whenever the patient's history is suggestive of deep venous thrombosis or the clinical status is stage 2 or 3 (Ad Hoc Committee classification). In patients with reflux in the popliteal fossa, Duplex Scan is helpful because physical examination and Doppler cannot correctly differentiate short saphenous insufficiency, gastrocnemius insufficiency and reflux in the popliteal-tibial axis, especially as these physiopathologic mechanisms may be associated. In patients with atypical varices, Duplex Scan can demonstrate: Absence of reflux in the greater saphenous vein-femoral vein termination or the short saphenous vein-popliteal vein termination. Varices in the lateral or posterior thigh. In patients with varicose vein thrombosis, Duplex Scan can reveal: The extent of any association with deep venous system. The extent of superficial venous thrombosis. When the results of varicose vein surgery are unsatisfactory, Duplex Scan can determine whether a redo surgery is justified: Persistence of a major leak between the deep and superficial venous system usually prompts redo surgery. Less often, recurrence is due to primary deep valvular insufficiency, in which case valvuloplasty may be indicated.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. MRI in venous thromboembolic disease

    International Nuclear Information System (INIS)

    Sostman, H.D.; Debatin, J.F.; Spritzer, C.E.; Coleman, R.E.; Grist, T.M.; MacFall, J.R.

    1993-01-01

    We evaluated the ability of magnetic resonance (MR) imaging to detect deep venous thrombosis (DVT) and pulmonary embolism (PE). MR venography was performed on 217 patients suspected of having DVT. Cine-MR imaging of the pulmonary arteries was performed in 14 other patients who were thought to have PE based on other imaging studies. In a third group of 5 patients, MR pulmonary angiograms were performed in the sagittal and coronal planes with a multislice fast gradient recalled echo technique. All but one of the 217 MR venograms were technically adequate. In 72 patients with correlative imaging studies (venography and ultrasound) MR venography was 99% sensitive and 95% specific. On the basis of follow-up (mean 8.3 months), no false-negative MR venograms were detected in an additional 64 patients. In 11 other patients MR revealed a diagnosis other than DVT. Cine-MR showed PE in all 14 patients evaluated. MR pulmonary arteriography demonstrated filling defects consistent with acute PE in 2 of 3 patients with acute PE; in the third patient only a questionable filling defect was seen. Coarctations or webs were found in the pulmonary arteries of both patients with chronic PE. These preliminary data suggest that MR imaging may be able to evaluate both the peripheral venous and the pulmonary arterial component of venous thromboembolic disease. Further technical refinement and more extensive clinical experience will be required to establish the role of this method in diagnosing pulmonary embolism, but MR venography is now used routinely in our hospital for the diagnosis of deep venous thrombosis. (orig.)

  19. Comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system in image-guided central venous catheter placement in children weighing less than 10 kg

    Energy Technology Data Exchange (ETDEWEB)

    Miraglia, Roberto; Maruzzelli, Luigi; Cortis, Kelvin; Gerasia, Roberta; Maggio, Simona; Luca, Angelo [Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Piazza, Marcello [Department of Anesthesia, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Tuzzolino, Fabio [Department of Information Technology, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy)

    2014-09-10

    Ultrasound-guided central venous puncture and fluoroscopic guidance during central venous catheter (CVC) positioning optimizes technical success and lowers the complication rates in children, and is therefore considered standard practice. The purpose of this study was to compare the radiation exposure levels recorded during CVC placement in children weighing less than 10 kg in procedures performed using an image intensifier-based angiographic system (IIDS) to those performed in a flat-panel detector-based interventional suite (FPDS). A retrospective review of 96 image-guided CVC placements, between January 2008 and October 2013, in 49 children weighing less than 10 kg was performed. Mean age was 8.2 ± 4.4 months (range: 1-22 months). Mean weight was 7.1 ± 2.7 kg (range: 2.5-9.8 kg). The procedures were classified into two categories: non-tunneled and tunneled CVC placement. Thirty-five procedures were performed with the IIDS (21 non-tunneled CVC, 14 tunneled CVC); 61 procedures were performed with the FPDS (47 non-tunneled CVC, 14 tunneled CVC). For non-tunneled CVC, mean DAP was 113.5 ± 126.7 cGy cm{sup 2} with the IIDS and 15.9 ± 44.6 cGy . cm{sup 2} with the FPDS (P < 0.001). For tunneled CVC, mean DAP was 84.6 ± 81.2 cGy . cm{sup 2} with the IIDS and 37.1 ± 33.5 cGy cm{sup 2} with the FPDS (P = 0.02). The use of flat-panel angiographic equipment reduces radiation exposure in small children undergoing image-guided CVC placement. (orig.)

  20. A closed-loop supply chain inventory model for manufacturer - Collector system with inspection, waste disposal and price-quality dependent return rate

    Science.gov (United States)

    Putri, Anissa Rianda; Jauhari, Wakhid Ahmad; Rosyidi, Cucuk Nur

    2017-11-01

    This paper studies a closed-loop supply chain inventory model, where the primary market demand is fulfilled by newly produced products and remanufactured products. We intend to integrate a manufacturer and a collector as a supply chain system. Used items are collected and will be inspected and sorted by the collector, and the return rate of used items is depended upon price and quality factor. Used items that aren't pass this process, will be considered as waste and undergone waste disposal process. Recoverable used items will be sent to the manufacturer for recovery process. This paper applies two types of the recovery process for used products, i.e. remanufacture and refurbish. The refurbished items are sold to a secondary market with lower price than primary market price. Further, the amount of recoverable items depend upon the acceptance level of the returned items. This proposed model gives an optimal solution by maximizing the joint total profit. Moreover, a numerical example is presented to describe the application of the model.

  1. Tillage practices and straw-returning methods affect topsoil bacterial community and organic C under a rice-wheat cropping system in central China

    Science.gov (United States)

    Guo, Lijin; Zheng, Shixue; Cao, Cougui; Li, Chengfang

    2016-09-01

    The objective of this study was to investigate how the relationships between bacterial communities and organic C (SOC) in topsoil (0-5 cm) are affected by tillage practices [conventional intensive tillage (CT) or no-tillage (NT)] and straw-returning methods [crop straw returning (S) or removal (NS)] under a rice-wheat rotation in central China. Soil bacterial communities were determined by high-throughput sequencing technology. After two cycles of annual rice-wheat rotation, compared with CT treatments, NT treatments generally had significantly more bacterial genera and monounsaturated fatty acids/saturated fatty acids (MUFA/STFA), but a decreased gram-positive bacteria/gram-negative bacteria ratio (G+/G-). S treatments had significantly more bacterial genera and MUFA/STFA, but had decreased G+/G- compared with NS treatments. Multivariate analysis revealed that Gemmatimonas, Rudaea, Spingomonas, Pseudomonas, Dyella, Burkholderia, Clostridium, Pseudolabrys, Arcicella and Bacillus were correlated with SOC, and cellulolytic bacteria (Burkholderia, Pseudomonas, Clostridium, Rudaea and Bacillus) and Gemmationas explained 55.3% and 12.4% of the variance in SOC, respectively. Structural equation modeling further indicated that tillage and residue managements affected SOC directly and indirectly through these cellulolytic bacteria and Gemmationas. Our results suggest that Burkholderia, Pseudomonas, Clostridium, Rudaea, Bacillus and Gemmationas help to regulate SOC sequestration in topsoil under tillage and residue systems.

  2. Significance of venous anastomosis in fingertip replantation.

    Science.gov (United States)

    Hattori, Yasunori; Doi, Kazuteru; Ikeda, Keisuke; Abe, Yukio; Dhawan, Vikas

    2003-03-01

    Adequate venous outflow is the most important factor for successful fingertip replantation. The authors have attempted venous anastomosis in all cases of fingertip replantation to overcome postoperative congestion. In this article, the significance of venous repair for fingertip replantation is described from the authors' results of 64 complete fingertip amputations in 55 consecutive patients, which were replanted from January of 1996 to June of 2001. The overall survival rate was 86 percent. Of the 44 replantations in zone I, 37 survived, and the success rate was 84 percent. Of the 20 replantations in zone II, 18 survived, and the success rate was 90 percent. Venous anastomosis was attempted in all cases, but it was possible in 39 zone I and in all zone II replantations. For arterial repair, vein grafts were necessary in 17 of the 44 zone I and in one of the 20 zone II replantations; for venous repair, they were necessary in six zone I replantations and one zone II replantation. Postoperative vascular complications occurred in 15 replantations. There were five cases of arterial thrombosis and 10 cases of venous congestion. Venous congestion occurred in nine zone I and one zone II replantations. In five of these 10 replantations, venous anastomosis was not possible. In another five replantations, venous outflow was established at the time of surgery, but occlusion occurred subsequently. Except for the five failures resulting from arterial thrombosis, successful venous repair was possible in 49 of 59 replantations (83 percent). Despite the demand for skillful microsurgical technique and longer operation time, the authors' results using venous anastomosis in successful fingertip replantations are encouraging. By performing venous anastomosis, external bleeding can be avoided and a higher survival rate can be achieved. Venous anastomosis for fingertip replantation is a reliable and worthwhile procedure.

  3. Cerebral sino-venous thrombosis

    International Nuclear Information System (INIS)

    Sayama, Ichiro; Kobayashi, Tsunesaburo; Nakajima, Kenji

    1982-01-01

    Three cases of cerebral sino-venous thrombosis were reported. Repeated CT findings were studied and discussed on account of the treatments for those pathologic conditions. Those of studied cases are; a 22-year-old postpartum woman, a 42-year-old woman with irregular vaginal bleeding, and a 26-year-old man with severe reactive emesis after drinking alcohol. They were treated conservatively. Case 1 died in its acute stage. In the remaining ones, each had an uneventful recovery. CT scan findings of them manifested their exact clinical conditions. These findings were devided into two categories, one was direct signs expressed sino-venous occlusion, the other was indirect signs which appeared as a result of these occlusion. Direct signs cannot always get in every cases with sino-venous occlusion, but as for indirect signs, we can get various changes corresponding to the time taken CT photoes, and they are useful to decide appropriate treatments at that time. Considering suitable treatments for this disease, it is necessary to select most suitable ones according to their pathologic conditions, which may be precisely drawn with CT scans. (J.P.N.)

  4. The place of subfascial endoscopic perforator vein surgery (SEPS in advanced chronic venous insufficiency treatment

    Directory of Open Access Journals (Sweden)

    Wiesław Pesta

    2011-12-01

    Full Text Available In spite of medical science development and initiation of new technologies in minimally invasive surgery, treatmentof advanced chronic venous insufficiency at the 5th and 6th degree of CEAP classification is still a great clinical challenge.In case of no satisfactory results of non-surgical treatment of recurrent venous ulcers, scientists search for alternativetherapeutic methods which could be more effective and lasting. Subfascial endoscopic perforator vein surgery(SEPS as a method of reducing venous pressure in the superficial venous system could provide healing of the recurrentvenous ulcer. In this study we present a review of contemporary opinions about the place and significance of subfascialendoscopic perforator vein surgery as a treatment of advanced chronic venous insufficiency.

  5. The Reference Return Ratio

    DEFF Research Database (Denmark)

    Nicolaisen, Jeppe; Faber Frandsen, Tove

    2008-01-01

    The paper introduces a new journal impact measure called The Reference Return Ratio (3R). Unlike the traditional Journal Impact Factor (JIF), which is based on calculations of publications and citations, the new measure is based on calculations of bibliographic investments (references) and returns...

  6. Characterization of Space Shuttle Thermal Protection System (TPS) Materials for Return-to-Flight following the Shuttle Columbia Accident Investigation

    Science.gov (United States)

    Wingard, Doug

    2006-01-01

    During the Space Shuttle Columbia Accident Investigation, it was determined that a large chunk of polyurethane insulating foam (= 1.67 lbs) on the External Tank (ET) came loose during Columbia's ascent on 2-1-03. The foam piece struck some of the protective Reinforced Carbon-Carbon (RCC) panels on the leading edge of Columbia's left wing in the mid-wing area. This impact damaged Columbia to the extent that upon re-entry to Earth, superheGed air approaching 3,000 F caused the vehicle to break up, killing all seven astronauts on board. A paper after the Columbia Accident Investigation highlighted thermal analysis testing performed on External Tank TPS materials (1). These materials included BX-250 (now BX-265) rigid polyurethane foam and SLA-561 Super Lightweight Ablator (highly-filled silicone rubber). The large chunk of foam from Columbia originated fiom the left bipod ramp of the ET. The foam in this ramp area was hand-sprayed over the SLA material and various fittings, allowed to dry, and manually shaved into a ramp shape. In Return-to-Flight (RTF) efforts following Columbia, the decision was made to remove the foam in the bipod ramp areas. During RTF efforts, further thermal analysis testing was performed on BX-265 foam by DSC and DMA. Flat panels of foam about 2-in. thick were sprayed on ET tank material (aluminum alloys). The DSC testing showed that foam material very close to the metal substrate cured more slowly than bulk foam material. All of the foam used on the ET is considered fully cured about 21 days after it is sprayed. The RTF culminated in the successful launch of Space Shuttle Discovery on 7-26-05. Although the flight was a success, there was another serious incident of foam loss fiom the ET during Shuttle ascent. This time, a rather large chunk of BX-265 foam (= 0.9 lbs) came loose from the liquid hydrogen (LH2) PAL ramp, although the foam did not strike the Shuttle Orbiter containing the crew. DMA testing was performed on foam samples taken fiom

  7. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriëtte; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michaël A.; Spronk, Peter E.

    2012-01-01

    Objective: The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design: Prospective observational controlled study. Setting: Nonacademic university-affiliated

  8. Clinicoroentgenological diagnosis of chronic venous ovarian insufficiency

    International Nuclear Information System (INIS)

    Grakova, L.S.; Galkin, E.V.; Naumova, E.B.

    1989-01-01

    The paper is devoted to clinicoroentgenological correlations of venous renogonadal hemodynamics in 168 women of reproductive age (151 women with infertility, habitual abortion, disordered menstrual function and 17 patients without disorders of the reproductive tract). Clinicolaboratory investigation was followed by visceral and parietal flebography for the detection of a pathological venous reflux into the ovarian pampiniform plexus. Clinicoroentgenological semiotics of chronic venous ovarian insufficiency was analyzed. Infertility was shown to be the main clinical manifestation of ovarian varicocele

  9. Capturing asteroids into bound orbits around the earth: Massive early return on an asteroid terminal defense system

    International Nuclear Information System (INIS)

    Hills, J.G.

    1992-01-01

    Nuclear explosives may be used to capture small asteroids (e.g., 20--50 meters in diameter) into bound orbits around the earth. The captured objects could be used for construction material for manned and unmanned activity in Earth orbit. Asteroids with small approach velocities, which are the ones most likely to have close approaches to the Earth, require the least energy for capture. They are particularly easy to capture if they pass within one Earth radius of the surface of the Earth. They could be intercepted with intercontinental missiles if the latter were retrofit with a more flexible guiding and homing capability. This asteroid capture-defense system could be implemented in a few years at low cost by using decommissioned ICMs. The economic value of even one captured asteroid is many times the initial investment. The asteroid capture system would be an essential part of the learning curve for dealing with larger asteroids that can hit the earth

  10. Returnable containers: an example of reverse logistics

    NARCIS (Netherlands)

    L.G. Kroon (Leo); G.M.C. Vrijens

    1996-01-01

    textabstractConsiders the application of returnable containers as an example of reverse logistics. A returnable container is a type of secondary packaging that can be used several times in the same form, in contrast with traditional cardboard boxes. For this equipment to be used, a system for the

  11. The Return-risk Performance of Selected Pension Fund in OECD with Focus on the Czech Pension System

    Directory of Open Access Journals (Sweden)

    Petr Kupčík

    2016-01-01

    Full Text Available This paper focuses on the measuring and comparing investment performance of pension funds in selected European countries. Comparison of the investment performance of pension funds is determined by means of the Sharpe ratio and the Sortino ratio. We used data of nominal appreciation of pension funds from the Czech Republic, Slovakia, Poland, Sweden, Switzerland and the Netherlands in the period 2005−2013. These countries were selected because they have many common features but Sweden, Switzerland and the Netherlands were added to the analysis because we wanted to show the differences between a developed and less developed fully funded system. The last part of this article presents the main causes of the differences in investment performance of pension funds. Conclusions of the paper are focused on a comparison of the results of the Sharpe ratio and the Sortino ratio of pension funds from selected countries and recommendations for the Czech pension system. The article proposes a mechanism for determining the order of the negative Sharpe ratio and the Sortino ratio.

  12. Lidar 2009 - All Returns

    Data.gov (United States)

    Kansas Data Access and Support Center — LIDAR-derived binary (.las) files containing classified points of all returns. We have 3 classifications Unclassified, Ground, Low points. The average Ground Sample...

  13. Comet coma sample return instrument

    Science.gov (United States)

    Albee, A. L.; Brownlee, Don E.; Burnett, Donald S.; Tsou, Peter; Uesugi, K. T.

    1994-01-01

    The sample collection technology and instrument concept for the Sample of Comet Coma Earth Return Mission (SOCCER) are described. The scientific goals of this Flyby Sample Return are to return to coma dust and volatile samples from a known comet source, which will permit accurate elemental and isotopic measurements for thousands of individual solid particles and volatiles, detailed analysis of the dust structure, morphology, and mineralogy of the intact samples, and identification of the biogenic elements or compounds in the solid and volatile samples. Having these intact samples, morphologic, petrographic, and phase structural features can be determined. Information on dust particle size, shape, and density can be ascertained by analyzing penetration holes and tracks in the capture medium. Time and spatial data of dust capture will provide understanding of the flux dynamics of the coma and the jets. Additional information will include the identification of cosmic ray tracks in the cometary grains, which can provide a particle's process history and perhaps even the age of the comet. The measurements will be made with the same equipment used for studying micrometeorites for decades past; hence, the results can be directly compared without extrapolation or modification. The data will provide a powerful and direct technique for comparing the cometary samples with all known types of meteorites and interplanetary dust. This sample collection system will provide the first sample return from a specifically identified primitive body and will allow, for the first time, a direct method of matching meteoritic materials captured on Earth with known parent bodies.

  14. Return to Bangka Island.

    Science.gov (United States)

    Spence, J

    2001-07-01

    This article is a return in a couple of ways to one of the most tragic events in the history of Australian military nursing. Firstly, it describes how the evacuation of nurses from Singapore in 1941 led to circumstances that resulted in the massacre or internment of many of those women. Then in 1993, a group of surviving World War II nurses and current serving Australian Army nurses returned to the site of their sorrow.

  15. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  16. VENOUS ULCER--A NEW THERAPEUTIC APPROACH.

    Science.gov (United States)

    Popa, R F; Cazan, I; Baroi, Genoveva; Cazan, Simona; Lefter, G; Strobescu, Cristina

    2016-01-01

    Trophic leg ulcer is a major health problem affecting approximately 1-2% of the population, the incidence being higher in the elderly (70-80 years). It is a multifactorial condition, but the most common cause is chronic venous insufficiency. This can be attributed to reflux in the saphenous system and calf perforator vein incompetence. These were first described by Linton, the first intervention designed to correct perforator vein incompetence bearing his name. Today Linton's operation has been abandoned due to the large unaesthetic incision and great postoperative pain. Also, ulcer healing time is long (2 months) and recurrence rate is high. Currently a series of minimally invasive procedures are used to close these perforator veins, such as ultrasound-guided sclerotherapy. The advantages of these techniques are less discomfort to the patients, low rate of complications, short hospital stay.

  17. Non-return valves do not prevent backflow and bacterial contamination of intravenous infusions

    NARCIS (Netherlands)

    Ellger, B.; Kiski, D.; Diem, E.; van den Heuvel, I.; Freise, H.; Van Aken, H.; Hinder, F.; Friedrich, A. W.

    Non-return valves (NRVs) are designed to avoid backflow of infusion fluid against the designated direction of flow (DDF) when more than one infusion is delivered via one venous access. We tested in vitro whether NRVs reliably prevent flow against the DDF at clinically relevant low flow rates. Since

  18. Phobos Sample Return: Next Approach

    Science.gov (United States)

    Zelenyi, Lev; Martynov, Maxim; Zakharov, Alexander; Korablev, Oleg; Ivanov, Alexey; Karabadzak, George

    The Martian moons still remain a mystery after numerous studies by Mars orbiting spacecraft. Their study cover three major topics related to (1) Solar system in general (formation and evolution, origin of planetary satellites, origin and evolution of life); (2) small bodies (captured asteroid, or remnants of Mars formation, or reaccreted Mars ejecta); (3) Mars (formation and evolution of Mars; Mars ejecta at the satellites). As reviewed by Galimov [2010] most of the above questions require the sample return from the Martian moon, while some (e.g. the characterization of the organic matter) could be also answered by in situ experiments. There is the possibility to obtain the sample of Mars material by sampling Phobos: following to Chappaz et al. [2012] a 200-g sample could contain 10-7 g of Mars surface material launched during the past 1 mln years, or 5*10-5 g of Mars material launched during the past 10 mln years, or 5*1010 individual particles from Mars, quantities suitable for accurate laboratory analyses. The studies of Phobos have been of high priority in the Russian program on planetary research for many years. Phobos-88 mission consisted of two spacecraft (Phobos-1, Phobos-2) and aimed the approach to Phobos at 50 m and remote studies, and also the release of small landers (long-living stations DAS). This mission implemented the program incompletely. It was returned information about the Martian environment and atmosphere. The next profect Phobos Sample Return (Phobos-Grunt) initially planned in early 2000 has been delayed several times owing to budget difficulties; the spacecraft failed to leave NEO in 2011. The recovery of the science goals of this mission and the delivery of the samples of Phobos to Earth remain of highest priority for Russian scientific community. The next Phobos SR mission named Boomerang was postponed following the ExoMars cooperation, but is considered the next in the line of planetary exploration, suitable for launch around 2022. A

  19. Returns to Education across Europe

    OpenAIRE

    Glocker, Daniela; Steiner, Viktor

    2011-01-01

    Incentives to invest in higher education are affected by both the direct wage effect of human capital investments and the indirect wage effect resulting from lower unemployment risks and shorter spells in unemployment associated with higher educated. We analyse the returns to education in Austria, Germany, Italy, Sweden and the United Kingdom, countries which differ significantly regarding both their education systems and labour market structure. We estimate augmented Mincerian wage equations...

  20. Risk Factors for Cerebral Venous Thrombosis

    NARCIS (Netherlands)

    Silvis, Suzanne M.; Middeldorp, Saskia; Zuurbier, Susanna M.; Cannegieter, Suzanne C.; Coutinho, Jonathan M.

    2016-01-01

    Cerebral venous thrombosis (CVT) is a rare thrombotic disorder involving the cerebral veins and dural sinuses. In contrast to more common sites of venous thromboembolism (VTE), such as the legs and lungs, CVT mainly affects young adults and children, and women are affected three times more often

  1. Venous Thromboembolism in Patients With Thrombocytopenia

    DEFF Research Database (Denmark)

    Bælum, Jens Kristian; Ellingsen Moe, Espen; Nybo, Mads

    2017-01-01

    BACKGROUND: Venous thromboembolism (VTE) is a frequent and potentially lethal condition. Venous thrombi are mainly constituted of fibrin and red blood cells, but platelets also play an important role in VTE formation. Information about VTE in patients with thrombocytopenia is, however, missing. O...

  2. Pulmonary venous abnormalities encountered on pre ...

    African Journals Online (AJOL)

    Multidetector computed tomography (MDCT) elegantly renders pulmonary venous anatomy. With increasing numbers of radiofrequency ablation procedures being performed, there is now a greater emphasis on pre-procedure imaging to delineate this anatomy. Pulmonary venous mapping studies can be performed with or ...

  3. An unusual Complication of Central Venous Cannulation

    Directory of Open Access Journals (Sweden)

    Ashvini Kumar

    2013-04-01

    Full Text Available Central venous catheter (CVC hub fracture is a rare complication of central venous cannulation. We report a case where catheter hub fracture was detected immediately after CVC insertion. Causes of catheter hub fracture and its complications are discussed.

  4. Urethro-venous intravasation during urethrography

    African Journals Online (AJOL)

    J.M. Ratkal

    urethrography. Two weeks prior to retrograde urethrography, he had presented with urinary retention. At that time, a suprapubic catheter had been placed after a failed attempt at catheterization. Apart from a proximal urethral stricture, the urethrogram also showed the penile venous anatomy, indicating urethro-venous.

  5. Genetic risk factors of venous thrombosis

    NARCIS (Netherlands)

    Franco, R. F.; Reitsma, P. H.

    2001-01-01

    Venous thrombosis, whose main clinical presentations include deep vein thrombosis and pulmonary embolism, represents a major health problem worldwide. Numerous conditions are known to predispose to venous thrombosis and these conditions are commonly referred to as risk indicators or risk factors.

  6. Venous and arterial thrombosis in dialysis patients

    NARCIS (Netherlands)

    Ocak, Gurbey; Vossen, Carla Y.; Rotmans, Joris I.; Lijfering, Willem M.; Rosendaal, Frits R.; Parlevliet, Karien J.; Krediet, Ray T.; Boeschoten, Els W.; Dekker, Friedo W.; Verduijn, Marion

    2011-01-01

    Whether the risk of both venous and arterial thrombosis is increased in dialysis patients as compared to the general population is unknown. In addition, it is unknown which subgroups are at highest risk. Furthermore, it is unknown whether having a history of venous thrombosis or arterial thrombosis

  7. Sex-specific aspects of venous thrombosis

    NARCIS (Netherlands)

    Roach, Rachel Elizabeth Jo

    2014-01-01

    Venous thrombosis is a disease that occurs in 1-2 per 1000 people per year. At the time of their first venous thrombosis, approximately 50% of women are exposed to reproductive risk factors (oral contraception, postmenopausal hormone therapy, pregnancy and the puerperium). In this thesis, we showed

  8. Anticoagulation and delayed bowel resection in the management of mesenteric venous thrombosis.

    Science.gov (United States)

    Kim, Hyung-Kee; Chun, Jae Min; Huh, Seung

    2013-08-14

    Acute mesenteric venous thrombosis is potentially lethal because it can result in mesenteric ischemia and, ultimately, bowel infarction requiring surgical intervention. Systemic anticoagulation for the prevention of thrombus propagation is a well-recognized treatment modality and the current mainstay therapy for patients with acute mesenteric venous thrombosis. However, the decision between prompt surgical exploration vs conservative treatment with anticoagulation is somewhat difficult in patients with suspected bowel ischemia. Here we describe a patient with acute mesenteric venous thrombosis who presented with bowel ischemia and was treated with anticoagulation and delayed short-segment bowel resection.

  9. Central Venous Catheter-directed Tissue Plasminogen Activator in Massive Pulmonary Embolism

    OpenAIRE

    Vishal Gulati

    2018-01-01

    We present the case of an 88-year-old female who presented to the emergency department (ED) with suspected massive pulmonary embolism (PE) causing respiratory failure, right heart strain, and shock, who despite early and aggressive resuscitation with vasopressors and continuous peripheral infusion of tissue plasminogen activator (tPA), suffered a cardiac arrest in the ED. We describe the approach of a tPA bolus directed through a central venous catheter, resulting in return of spontaneous cir...

  10. Increased rheumatoid factor and deep venous thrombosis

    DEFF Research Database (Denmark)

    Meyer-Olesen, Christine L; Nielsen, Sune F; Nordestgaard, Børge G

    2015-01-01

    was incident deep venous thrombosis. There were no losses to follow-up. RESULTS: During 368381 person-years, 670 individuals developed deep venous thrombosis. A rheumatoid factor concentration ≥ vs ...BACKGROUND: The risk of deep venous thrombosis is increased in patients with rheumatoid arthritis. We tested the hypothesis that increased concentrations of rheumatoid factor are associated with increased risk of deep venous thrombosis in individuals without autoimmune rheumatic disease...... in the general population. METHODS: We included 54628 participants from the Copenhagen City Heart Study (1981-83) and the Copenhagen General Population Study (2004-12), all with a measured concentration of IgM rheumatoid factor and without autoimmune rheumatic disease or venous thromboembolism. The main outcome...

  11. Practical use of a uterine score system for predicting effects on interval from calving to first insemination and non-return rate 56 in Danish dairy herds.

    Science.gov (United States)

    Elkjær, Karina; Labouriau, Rodrigo; Ancker, Marie-Louise; Gustafsson, Hans; Callesen, Henrik

    2013-12-01

    A detailed study of 398,237 lactations of Danish Holstein dairy cows was undertaken. The objective was to investigate the information gained by evaluating vaginal discharge in cows from 5 to 19 days post-partum (p.p.) using an ordinal scale from 0 to 9. The study focused on the interval from calving to first insemination (CFI) and the non-return rate 56 days after first insemination (NR56), adjusted for the confounders milk production and body condition score (BCS). For the analyses, BCS was evaluated on the same day that the uterine score was made. Milk production was defined as test-day milk yield in the first month p.p. The study showed that the evaluation of vaginal discharge according to this score system permitted ranking of cows according to CFI and NR56, i.e. an increasing uterine score was associated with a significantly longer time from calving to first insemination and significantly reduced the probability of success of the first insemination. Reproductive success was already affected if the uterine score had reached 4 (i.e. before the discharge smelled abnormally). The negative effect on CFI and NR56 increased as the uterine score increased, which suggested that the uterine scoring system was a useful guide to dairy producers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Gene expression profiles are different in venous and capillary blood: Implications for vaccine studies.

    Science.gov (United States)

    Stein, D F; O'Connor, D; Blohmke, C J; Sadarangani, M; Pollard, A J

    2016-10-17

    Detailed analysis of the immunological pathways leading to robust vaccine responses has become possible with the application of systems biology, including transcriptomic analysis. Venous blood is usually obtained for such studies but others have obtained capillary blood (e.g. finger-prick). Capillary samples are practically advantageous, especially in children. The aim of this study was to compare gene expression profiles in venous and capillary blood before, 12h and 24h after vaccination with 23-valent pneumococcal polysaccharide or trivalent inactivated seasonal influenza vaccines. Gene expression at baseline was markedly different between venous and capillary samples, with 4940 genes differentially expressed, and followed a different pattern of changes after vaccination. At baseline, multiple pathways were upregulated in venous compared to capillary blood, including transforming growth factor-beta receptor signalling and toll-like receptor cascades. After vaccination with the influenza vaccine, there was enrichment for T and NK cell related signatures in capillary blood, and monocyte signatures in venous blood. By contrast, after vaccination with the pneumococcal vaccination, there was enrichment of dendritic cells, monocytes and interferon related signatures in capillary blood, whilst at 24h there was enrichment for T and NK cell related signatures in venous blood. These data show differences between venous and capillary gene expression both at baseline, and post vaccination, which may impact on the conclusions regarding immunological mechanisms drawn from studies using these different sampling methodologies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Morphological dilemma: Anomalous pulmonary venous confluence or cor triatriatum-does it matter?

    Science.gov (United States)

    Muthialu, Nagarajan

    2018-01-01

    Cardiac variant of total anomalous pulmonary venous return is a rare entity, whereby all the pulmonary veins drain directly to the right atrium or coronary sinus. The effective left heart blood flow channels through a small stretched patent foramen ovale and can often be confused with a variant of cor triatriatum. Cor triatriatum is a rare congenital cardiac anomaly where pulmonary veins drain to a persistent chamber above the left atrium with a membrane separating these two. There persists either a small aperture directly from the true to the accessory left atrium or none at all. Where there is no such aperture, it is often physiologically akin to the cardiac variant of total anomalous pulmonary venous return described above. Such morphological differentiation is often challenging in a clinical situation, but the effective treatment remains the same. It involves removal of the common wall between the two chambers and baffling the pulmonary veins effectively to the left atrium. We describe such a case where the pulmonary venous return is to the right atrium, managed recently in our centre, and discuss the morphological differences between these two.

  14. No association of abnormal cranial venous drainage with multiple sclerosis: a magnetic resonance venography and flow-quantification study

    NARCIS (Netherlands)

    Wattjes, M.P.; van Oosten, B.W.; de Graaf, W.L.; Seewann, A.M.; Bot, J.C.J.; van den Berg, R.; Uitdehaag, B.M.J.; Polman, C.H.; Barkhof, F.

    2011-01-01

    Background: Recent studies using colour-coded Doppler sonography showed that chronic impaired venous drainage from the central nervous system is almost exclusively found in multiple sclerosis (MS) patients. This study aimed to investigate the intracranial and extracranial venous anatomy and the

  15. No association of abnormal cranial venous drainage with multiple sclerosis: a magnetic resonance venography and flow-quantification study

    NARCIS (Netherlands)

    Wattjes, Mike P.; van Oosten, Bob W.; de Graaf, Wolter L.; Seewann, Alexandra; Bot, Joseph C. J.; van den Berg, René; Uitdehaag, Bernard M. J.; Polman, Chris H.; Barkhof, Frederik

    2011-01-01

    Recent studies using colour-coded Doppler sonography showed that chronic impaired venous drainage from the central nervous system is almost exclusively found in multiple sclerosis (MS) patients. This study aimed to investigate the intracranial and extracranial venous anatomy and the intracerebral

  16. Lymphatic System Flows

    Science.gov (United States)

    Moore, James E., Jr.; Bertram, Christopher D.

    2018-01-01

    The supply of oxygen and nutrients to tissues is performed by the blood system and involves a net leakage of fluid outward at the capillary level. One of the principal functions of the lymphatic system is to gather this fluid and return it to the blood system to maintain overall fluid balance. Fluid in the interstitial spaces is often at subatmospheric pressure, and the return points into the venous system are at pressures of approximately 20 cmH2O. This adverse pressure difference is overcome by the active pumping of collecting lymphatic vessels, which feature closely spaced one-way valves and contractile muscle cells in their walls. Passive vessel squeezing causes further pumping. The dynamics of lymphatic pumping have been investigated experimentally and mathematically, revealing complex behaviors that indicate that the system performance is robust against minor perturbations in pressure and flow. More serious disruptions can lead to incurable swelling of tissues called lymphedema.

  17. The Returns to Entrepreneurship

    DEFF Research Database (Denmark)

    Van Praag, Mirjam; Raknerud, Arvid

    Empirical studies show low pecuniary returns of switching from wage employment to entrepreneurship. We reconsider the pecuniary gains of this switching by employing a two-stage procedure, where the randomness in the timing of inheritance transfers is used as an exclusion restriction to identify...... causal effects. The model is estimated on data covering the whole Norwegian population of individuals matched to the entire population of firms established in the period 2002-2011. The results indicate that the average returns to entrepreneurship are significantly negative for individuals entering...... entrepreneurship through self-employment and modest, but significantly positive, for incorporated startups....

  18. Return to nucleate boiling

    International Nuclear Information System (INIS)

    Shumway, R.W.

    1985-01-01

    This paper presents a collection of TMIN (temperature of return to nucleate boiling) correlations, evaluates them under several conditions, and compares them with a wide range of data. Purpose is to obtain the best one for use in a water reactor safety computer simulator known as TRAC-B. Return to nucleate boiling can occur in a reactor accident at either high or low pressure and flow rates. Most of the correlations yield unrealistic results under some conditions. A new correlation is proposed which overcomes many of the deficiencies

  19. Plasma return current discharge

    International Nuclear Information System (INIS)

    Mangano, J.A.; Hsia, J.; Jacob, J.H.; Srivastava, B.N.

    1978-01-01

    A discharge technique based on the use of an electron-beam-induced plasma return current to produce and heat large-volume plasmas is described. The results of discharge studies using this technique in attachment-dominated mixtures are presented. The results are found to be adequately described by a simple theory. The electron attachment rate by F 2 inferred from these measurements agrees well with those of other workers. KrF laser action at 248 nm is reported in return-current discharge-excited mixtures of F 2 /Kr/He

  20. To return permanently or to return temporarily?: Explaining migrants' intentions

    NARCIS (Netherlands)

    Bilgili, Ö.; Siegel, M.

    2014-01-01

    This paper studies migrants' intentions to return to their origin country by making the distinction between permanent return, temporary return and participation in temporary return programmes. Using survey data from first generation migrants in the Netherlands, we explore how migrants' experiences

  1. Clinical patterns of venous diseases and diagnostic demands on radiology

    International Nuclear Information System (INIS)

    Wienert, V.

    1988-01-01

    The author deals with the clinical signs and treatment of the valvular incompetence of the venae saphenae in varicosis of the lower extremities, varicosis or insufficiency of the venae perforantes (an insufficiency of the deep venous system, manifested by an insufficiency of the valvular system of the vena femoralis and venae saphenae but not representing a post-thrombotic syndrome), phlebothrombosis and postthrombosis. Routine phlebography for diagnosing a number of venous diseases has become redundant especially by the use of noninvasive methods such as Doppler ultrasound and light reflection rheography. However, if there is a suspicion of a deep thrombosis in the leg, phlebography is imperative. Dermatological phlebography specialists would like the radiologists to supply them with phlebographic criteria for the disease pattern of the insufficiency of the venae perforantes, vena femoralis and venae saphenae as mentioned above. Whether Duplex scanning can replace phlebography in the long run remains to be seen. (orig.) [de

  2. A Regular Production-Remanufacturing Inventory Model for a Two-Echelon System with Price-dependent Return Rate and Environmental Effects Investigation

    Science.gov (United States)

    Dwicahyani, A. R.; Jauhari, W. A.; Jonrinaldi

    2017-06-01

    Product take-back recovery has currently became a promising effort for companies in order to create a sustainable supply chain. In addition, some restrictions including government regulations, social-ethical responsibilities, and up to economic factors have contributed to the reasons for the importance of product take-back recovery. This study aims to develop an inventory model in a system of reverse logistic management consisting of a manufacturer and a collector. Recycle dealer collects used products from the market and ships it to manufacturer. Manufacturer then recovers the used products and sell it eventually to the market. Some recovered products that can not be recovered as good as new one will be sold to the secondary market. In this study, we investigate the effects of environmental factors including GHG emissions and energy usage from transportation, regular production, and remanufacturing operations conducted by manufacturer and solve the model to get the maximum annual joint total profit for both parties. The model also considers price-dependent return rate and determine it as a decision variable as well as number of shipments from collector to manufacturer and optimal cycle period. An iterative procedure is proposed to determine the optimal solutions. We present a numerical example to illustrate the application of the model and perform a sensitivity analysis to study the effects of the changes in environmental related costs on the model’s decision.

  3. Temporally stable population-specific differences in run timing of one-sea-winter Atlantic salmon returning to a large river system.

    Science.gov (United States)

    Vähä, Juha-Pekka; Erkinaro, Jaakko; Niemelä, Eero; Primmer, Craig R; Saloniemi, Irma; Johansen, Morten; Svenning, Martin; Brørs, Sturla

    2011-01-01

    The understanding of migration patterns can significantly contribute to conservation and management. The spawning migrations of Atlantic salmon (Salmo salar) cover thousands of kilometers from the feeding areas at sea to their natal rivers to reproduce. Migrating salmon are exposed to intensive harvest, but little is known of the population-specific differences in migration behavior. In this study, timing of return migration was investigated among one-sea-winter Atlantic salmon within a river system. By utilizing knowledge of the genetic population structure, population of origin was reliably identified for c. 1500 fish caught in mixed stock fisheries after adopting an approach to minimize the complications arising from potential nonsampled populations. Results demonstrated significant and temporally stable differences among populations as well as between sexes. Generally, female salmon from tributary populations entered fresh water first. Run timing was not however related to in-river migration distance. Rather, one-sea-winter salmon from larger populations and with a higher proportion of multi-sea-winter females arrived later in the season. These findings are a significant step toward a more thorough understanding of the salmon migration behavior and behavioral ecology, providing concrete tools for the management and conservation of the remaining indigenous Atlantic salmon stocks.

  4. [Evaluation of the Charing Cross Venous Ulcer Questionnaire in patients with chronic venous ulcers in Uruguay].

    Science.gov (United States)

    Tafernaberry, Gabriela; Otero, Gabriela; Agorio, Caroline; Dapueto, Juan J

    2016-01-01

    Chronic venous ulcers (CVU) represent a frequent condition, with difficult therapeutic approaches, that impact on patients’ quality of life, and generate an economic burden to patients and health systems. To perform the cultural adaptation and initial evaluation of the Charing Cross Venous Ulcer Questionnaire (CCVUQ) for Uruguay, and to study the health-related quality of life (HRQL) of patients with CVU. The translated and culturally adapted version of the CCVUQ was applied to a convenience sample of 50 patients. In addition, the PROMIS Global Health Survey was included in the assessment. Both questionnaires showed good internal consistency (Cronbach alfa > 0.70). A statistically significant association was observed between the CCVUQ total scores, its subscales and both dimensions of the PROMIS: Global Physical (GPH) and Global Mental Health (GMH) (rho ≥ 0.40). The CCVUQ mean score was 54.9 ± 42 points while GPH and GMH mean scores were 37.9 ± 29 points, and 43.1 ± 35.1 points respectively. Simple linear regression showed that patients with higher income reported better emotional well-being, while in younger patients, ulcers had a higher impact on Emotional Status and Cosmetics. The translated and adapted version of the CCVUQ was easy to comprehend and apply, showing good psychometric properties. When used in association with the PROMIS Global Health Measure it provides complementary information. HRQL was severely affected in the study sample.

  5. Central Venous Catheter-Associated Deep Venous Thrombosis in Critically Ill Children.

    Science.gov (United States)

    Faustino, Edward Vincent S

    2018-02-01

    The presence of a central venous catheter and admission to the intensive care unit are the most important risk factors for deep venous thrombosis (DVT) in children. At least 18% of critically ill children with a catheter develop radiologically confirmed catheter-associated thrombosis. Clinically apparent thrombosis occurs in 3% of critically ill children with a catheter and is associated with 8 additional days of mechanical ventilation. Even when the thrombus is initially asymptomatic, 8 to 18% of critically ill children with catheter-associated thrombosis develop postthrombotic syndrome. Thrombosis is uncommon within 24 hours after insertion of a nontunneled catheter in critically ill children, but nearly all thrombi have developed by 4 days after insertion. Hypercoagulability during or immediately after insertion of the catheter plays an essential role in the development of thrombosis. Pharmacologic prophylaxis, including local anticoagulation with heparin-bonded catheter, has not been shown to reduce the risk of catheter-related thrombosis in children. Systemic anticoagulation in critically ill children started soon after the insertion of the catheter, however, may be beneficial. A multicenter clinical trial that is testing this hypothesis is currently underway. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. DISTAL SPLENORENAL VENOUS ANASTOMOSIS IN TREATMENT OF DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    T. I. Shraer

    2010-01-01

    Full Text Available We studied the outcomes of the operations for distal splenorenal venous anastomosis of 134 patients with type 1 diabetes mellitus. We have noticed the significant improvement of patient’s general condition due to spasmolytic effect of glucagon, bypassed to blood circulation without coming through liver and also a stabilization of glyce- mia because of a restoration of insulin-glucagon ratio in systemic circulation. The effect of a surgery depends on a stage of microangiopathy and nephrosclerosis. 

  7. The role of magnetic resonance imaging in assessing venous vascular abnormalities in the head and neck: a demonstration of cerebrospinal venous insufficiency in a subset of multiple sclerosis patients

    Directory of Open Access Journals (Sweden)

    E. Mark Haacke

    2015-06-01

    Full Text Available The study of chronic cerebrospinal venous insufficiency (CCSVI and its impact on the development and progression of multiple sclerosis (MS remains controversial. Although the initial thrust in evaluating CCSVI was with ultrasound, other modalities including magnetic resonance imaging (MRI have been used to study venous vascular abnormalities. This review focuses on the findings of a number of past MRI studies including a look at a combined study of four previous works with a cohort of 559 MS patients regarding structure and function of the extra-cranial vasculature. Strengths and limitations of each paper are discussed which give insight into conflicting reports of venous abnormalities in MS patients and healthy controls. Guidelines for data acquisition and analysis for future studies related to extra-cranial structure and flow, both arterial and venous, are discussed. This includes the grading of stenosis of the internal jugular veins (IJVs as well as normalized flows through major veins of the neck. The lack of agreement between most studies is likely due to inconsistent data acquisition and incomplete data analysis. Our own work over four independent sites shows good agreement, indicating that there is a high incidence of stenosis and structural venous abnormalities in the MS population and that this change results in reduced outflow of the IJVs and increased collateralization of venous return to the heart compared to healthy controls.

  8. Return to Play

    Science.gov (United States)

    Mangan, Marianne

    2013-01-01

    Call it physical activity, call it games, or call it play. Whatever its name, it's a place we all need to return to. In the physical education, recreation, and dance professions, we need to redesign programs to address the need for and want of play that is inherent in all of us.

  9. Higher Education Endowments Return

    Science.gov (United States)

    Bahlmann, David; Walda, John D.; Sedlacek, Verne O.

    2012-01-01

    A new study of endowments by the National Association of College and University Business Officers (NACUBO) and the Commonfund Institute has brought good news to college and universities: While endowment returns dropped precipitously in fiscal year 2009 as a result of the financial crisis and accompanying slide in equity markets, they climbed to an…

  10. Return telephone and telegraph

    International Nuclear Information System (INIS)

    1976-12-01

    This consists of eleven chapters, which are introduction on return of telephone, modulator and demodulator, transport mode like PCM, wave power for transportation, amplifier for transportation such as transistor, impedance, input-output circuit and voice telephone amplifier, circuit for transportation of telephone, line terminal equipment, standard for transportation, various telephone transport, basic telegraph transport and problems on circuit of transport of telephone.

  11. Return of qualified Sudanese

    Directory of Open Access Journals (Sweden)

    Lindsay T McMahon

    2007-07-01

    Full Text Available With the signing of the Comprehensive Peace Agreement in January 2005, the new Government of South Sudan began to call for the return of the millions of South Sudanese IDP s and refugees. The International Organization for Migration (IOM has developed a programme to help them do so.

  12. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  13. Interventional therapy of mesenteric venous thrombosis

    International Nuclear Information System (INIS)

    Li Xuan; Ouyang Qiang; Xiao Xiangsheng

    2006-01-01

    Objective: To evaluate the clinical effect of interventional therapy in treating intestinal ischemia of mesenteric venous thrombosis. Methods: Twelve cases (male 7 cases, female 5 cases; ranging from 33 to 86 years of age) of mesenteric venous thrombosis (MVT) were treated with percutaneous transhepatic mesenteric venous thrombectomy and thrombolysis associated with papaverin perfusion via superior mesenteric artery. Results: Seven of the 12 cases recovered; 3 cases were undertaken laparotomy; 2 died within 30 days respectively. No severe complications occurred in all of the 12 cases. Conclusions: Interventional therapy of MVT is a safe and effective method with reduction of the mortality. (authors)

  14. Doppler diagnosis of deep venous thrombosis

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The venous Doppler examination has been shown to be a sensitive test for the diagnosis of deep venous thrombosis. An experienced technologist can perform the examination in about ten minutes at the bedside or in the laboratory. Because the venous Doppler examination is subjective, it requires considerable experience of the examiner to achieve maximal accuracy. Nevertheless, with sufficient practice the technologist may employ this instrument with skill and versatility to detect both obstruction and valvular incompetence in the superficial, communicating, and deep veins of the lower and upper extremities

  15. Integrating Public Perspectives in Sample Return Planning

    Science.gov (United States)

    Race, Margaret S.; MacGregor, G.

    2001-01-01

    Planning for extraterrestrial sample returns, whether from Mars or other solar system bodies, must be done in a way that integrates planetary protection concerns with the usual mission technical and scientific considerations. Understanding and addressing legitimate societal concerns about the possible risks of sample return will be a critical part of the public decision making process ahead. This paper presents the results of two studies, one with lay audiences, the other with expert microbiologists, designed to gather information, on attitudes and concerns about sample return risks and planetary protection. Focus group interviews with lay subjects, using generic information about Mars sample return and a preliminary environmental impact assessment, were designed to obtain an indication of how the factual content is perceived and understood by the public. A research survey of microbiologists gathered information on experts' views and attitudes about sample return, risk management approaches and space exploration risks. These findings, combined with earlier research results on risk perception, will be useful in identifying levels of concern and potential conflicts in understanding between experts and the public about sample return risks. The information will be helpful in guiding development of the environmental impact statement and also has applicability to proposals for sample return from other solar system bodies where scientific uncertainty about extraterrestrial life may persist at the time of mission planning.

  16. The possibility for use of venous flaps in plastic surgery

    International Nuclear Information System (INIS)

    Baytinger, V. F.; Kurochkina, O. S.; Selianinov, K. V.; Baytinger, A. V.; Dzyuman, A. N.

    2015-01-01

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were no differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required

  17. The possibility for use of venous flaps in plastic surgery

    Science.gov (United States)

    Baytinger, V. F.; Kurochkina, O. S.; Selianinov, K. V.; Baytinger, A. V.; Dzyuman, A. N.

    2015-11-01

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were no differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.

  18. The possibility for use of venous flaps in plastic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.; Baytinger, A. V. [Research Institute of Microsurgery, Tomsk (Russian Federation); Dzyuman, A. N. [Siberian State Medical University, Tomsk (Russian Federation)

    2015-11-17

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were no differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.

  19. Yield, irrigation production efficiency and economic returns of ...

    African Journals Online (AJOL)

    ... gross return, net return and benefit-cost ratio exhibited quadratic relationship which can be used for optimising economic return of broccoli under variable irrigation and lateral spacing. The results revealed that drip irrigation system is profitable for broccoli production inspite of high initial investment. Journal of Science and ...

  20. Systematic review of topic treatment for venous ulcers Revisión sistemática del tratamiento tópico de la úlcera venosa Revisão sistemática do tratamento tópico da úlcera venosa

    OpenAIRE

    Eline Lima Borges; Maria Helena Larcher Caliri; Vanderlei José Haas

    2007-01-01

    Venous ulcer patients can experience this situation for several years without achieving healing if treatment is inadequate. Evidence-based professional practice generates effective results for patients and services. This research aimed to carry out a systematic review to assess the most effective method to improve venous return and the best topic treatment for these ulcers. Studies were collected in eight databases, using the following descriptors: leg ulcer, venous ulcer and similar terms. T...

  1. Spontaneous thrombosis of developmental venous anomaly (DVA) with venous infarct and acute cerebellar ataxia.

    Science.gov (United States)

    Agarwal, Amit; Kanekar, Sangam; Kalapos, Paul; Vijay, Kanupriya

    2014-08-01

    Developmental venous anomaly (DVA), formally known as venous angioma, is a congenital anatomic variant of the venous drainage of the brain. Although they typically have a benign clinical course and a low symptomatic rate, thrombosis of a drainage vein may occur, leading to potentially debilitating complications. We report a unique case of spontaneous thrombosis of a posterior fossa developmental venous anomaly with cerebellar infarct in a 61-year-old man who presented with acute onset cerebellar ataxia. DVA thrombosis was well-depicted on CT and MR studies. Patient was put on anticoagulant therapy and complete recanalization was seen on follow-up imaging.

  2. Venous sacrifice in neurosurgery: new insights from venous indocyanine green videoangiography.

    Science.gov (United States)

    Ferroli, Paolo; Acerbi, Francesco; Tringali, Giovanni; Albanese, Erminia; Broggi, Morgan; Franzini, Angelo; Broggi, Giovanni

    2011-07-01

    The purpose of this paper is to evaluate whether venous indocyanine green (ICG) videoangiography has any potential for predicting the presence of a safe collateral circulation for veins that are at risk for intentional or unintentional damage during surgery. The authors performed venous ICG videoangiography during 153 consecutive neurosurgical procedures. On those occasions in which a venous sacrifice occurred during surgery, whether that sacrifice was preplanned (intended) or unintended, venous ICG videoangiography was repeated so as to allow us to study the effect of venous sacrifice. A specific test to predict the presence of venous collateral circulation was also applied in 8 of these cases. Venous ICG videoangiography allowed for an intraoperative real-time flow assessment of the exposed veins with excellent image quality and resolution in all cases. The veins observed in this study were found to be extremely different with respect to flow dynamics and could be divided in 3 groups: 1) arterialized veins; 2) fast-draining veins with uniform filling and clear flow direction; and 3) slow-draining veins with nonuniform filling. Temporary clipping was found to be a simple and reversible way to test for the presence of potential anastomotic circulation. Venous ICG videoangiography is able to reveal substantial variability in the venous flow dynamics. "Slow veins," when they are tributaries of bridging veins, might hide a potential for anastomotic circulation that deserve further investigation.

  3. Low flow veno-venous ECMO: an experimental study.

    Science.gov (United States)

    Calderón, M; Verdín, R; Galván, J; Gonzalez, M; Cárdenas, H; Campos, R; Vidrio, H; Amezcua, J

    1994-01-01

    Clinical use of extracorporeal membrane oxygenation (ECMO) and carbon dioxide removal (ECCO 2R) have become well established techniques for the treatment of severe respiratory failure; however they require full cardiopulmonary bypass, representing major procedures with high morbidity. We theorized the possibility of an efficient low flow veno-venous extracorporeal membrane gas exchange method. Four mongrel 12 kg dogs were submitted to veno-venous extracorporeal membrane gas exchange via a jugular dialysis catheter using a low flow (10 ml/min) roller pump and a membrane oxygenator for a period of four hours. Respiratory rate was set at 4 breaths/min with a FiO 2 of 21% and ventilatory dead space was increased. Adequate gas exchange was obtained (pO 2139, pCO 224, Sat 99.4%), without major hemodynamic changes or hematuria. Our results demonstrate the feasibility of a low flow, less aggressive system. Further research should be considered.

  4. Arterio-venous malformations - classification, imaging and endovascular treatment

    International Nuclear Information System (INIS)

    Sirakov, S.

    2015-01-01

    Arterio-venous malformations of the brain (brain AVMs) correspond to congenital cerebrovascular anomalies. They are cause of death and long-term morbidity mostly due to intracranial hemorrhage and epilepsy; however, they may remain silent over a long period of time, even over an entire life. The most frequent clinical presentations of brain AVMs are hemorrhage, seizure, chronic headache, and focal deficits not related to hemorrhage. Several systems have been designed to classify patients with brain AVMs regarding surgical risk (Spetzler et al., 1992) and individual hemorrhagic risk (Nataf et al., 1998). Embolization of arterio-venous malformations of the brain is a promising method for treatment. Variety of techniques, embolic agents, and even basic treatment concepts from one team to another and then from one publication to another. (author)

  5. Tuberculosis and Venous Thromboembolism: a case series.

    Science.gov (United States)

    Goncalves, Ivone M; Alves, Daniela Costa; Carvalho, Aurora; do Ceu Brito, Maria; Calvario, Fernando; Duarte, Raquel

    2009-12-16

    Tuberculosis remains an infectious disease with a high prevalence worldwide and represents a major public health issue. Although venous thromboembolism is a rare complication of this disease, it may be a potentially life-threatening event. We report two cases of severe pulmonary tuberculosis associated with venous thromboembolism. A 38 year-old caucasian male that had a thromboembolic event as an unsual presentation form of tuberculosis and a 51 year-old caucasian male that developed deep venous thrombosis later in the course of the disease. An association between inflamation induced by tuberculosis and a hypercoagulable state has been described. Therefore, the occurence of deep venous thrombosis or pulmonary embolic episods, should be considered in patients with tuberculosis particulary during the first weeks of treatment. The physician's awarness of these phenomena is important to an early diagnostic suspicion and prompt treatment in order to prevent fatal outcomes.

  6. Intracranial developmental venous anomaly: is it asymptomatic?

    Science.gov (United States)

    Puente, A Bolívar; de Asís Bravo Rodríguez, F; Bravo Rey, I; Romero, E Roldán

    2018-03-16

    Intracranial developmental venous anomalies are the most common vascular malformation. In the immense majority of cases, these anomalies are asymptomatic and discovered incidentally, and they are considered benign. Very exceptionally, however, they can cause neurological symptoms. In this article, we present three cases of patients with developmental venous anomalies that presented with different symptoms owing to complications derived from altered venous drainage. These anomalies were located in the left insula, right temporal lobe, and cerebellum. The exceptionality of the cases presented as well as of the images associated, which show the mechanism through which the symptoms developed, lies in the low incidence of symptomatic developmental venous anomalies reported in the literature. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    and reliable evidence-based quality indicators of venous leg ulcer care. A Scandinavian multidisciplinary, cross-sectional panel of wound healing experts developed clinical quality indicators on the basis of scientific evidence from the literature and subsequent group nominal consensus of the panel......; an independent medical doctor tested the feasibility and reliability of these clinical indicators, assessing the quality of medical technical care on 100 consecutive venous leg ulcer patients. Main outcome measures were healing, recurrence, pain, venous disease diagnosis, differential diagnosis and treatment......%) were assessed for venous surgery. Distal arterial pressure was measured following initial examination in 33 of the patients (34%). All patients (100%) were prescribed compression therapy. Of the 98 patients, 11 (11%) had ulcers recur in 3 months and 72 (73%) healed in 12 months, which is in line...

  8. [Emphysematous gastritis with concomitant portal venous air].

    Science.gov (United States)

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.

  9. [Venous thromboembolic disease: presentation of a case].

    Science.gov (United States)

    Mirpuri-Mirpuri, P G; Álvarez-Cordovés, M M; Pérez-Monje, A

    2013-01-01

    Venous thromboembolic disease in its clinical spectrum includes both deep vein thrombosis and pulmonary thromboembolism, which is usually a complication of deep vein thrombosis. It is a relatively common disease with significant morbidity and requires an accurate diagnosis. They are numerous risk factors for venous thromboembolism, and there is evidence that the risk of thromboembolic disease increases proportionally to the number of predisposing risk factors present. The primary care physician should know the risk factors and suspect the presence of venous thromboembolic disease when there is a compatible clnical picture. The treatment for this pathology is anticoagulation. We report a patient with cardiovascular risk factors who was seen with pain in the right leg and shortness of breath and referred to the hospital with suspected venous thromboembolism, atrial fibrillation and pleural effusion. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  10. Fingertip replantation without venous anastomosis.

    Science.gov (United States)

    Chen, Yi-Chieh; Chan, Fuan Chiang; Hsu, Chung-Chen; Lin, Yu-Te; Chen, Chien-Tzung; Lin, Chih-Hung

    2013-03-01

    Replantation of amputated fingertips is a technical challenge, as many salvage procedures fail because no suitable vein in the fingertip is available for anastomosis. In this study, we examined our experience in fingertip replantation in cases without venous anastomosis with our established fingertip replantation treatment protocol. Between August 2002 and August 2010, a retrospective study examined all patients who had undergone fingertip replantation at Chang-Gung Memorial Hospital. All the patients (n = 24) suffered from complete digital amputations at or distal to the interphalangeal joint of the thumb, or distal to distal interphalangeal joint of the fingers. A total of 30 fingertips that were salvaged by microsurgical anastomosis of the digital arteries but not of digital veins were included in this study. On satisfactory arterial anastomosis, a 2-mm incision was made over the fingertip with a number 11 Scalpel blade, and 0.1 to 0.2 mL heparin (5000 IU/mL) was injected subcutaneously around the incision immediately and once per day thereafter to ensure continuous blood drainage from the replanted fingertip. None of the replanted nail plate was removed, and no medical leeches were used. The perfusion of the replanted digits and patient's hemoglobin level were closely monitored. The wound bleeding was maintained until physiologic venous outflow was restored. Of 30 fingertips, 27 (90%) replanted fingertips survived. The average length needed for maintaining external bleeding by chemical leech was 6.8 days (range, 5-10 days). Twelve patients (including a 2-year-old child) received blood transfusions. The average amount of blood transfusion in the 23 adults was 4.0 units (range, 0-16 units) for each patient or 3.29 units (range, 0-14 units) for each digit. A 2-year-old child received 100 mL blood transfusion or 50 mL for each digit. This study showed that a protocol that promotes controlled bleeding from the fingertip is essential to achieve consistent high

  11. Mesenteric angina through superior mesenteric venous thrombosis

    OpenAIRE

    Mohan, Divya; Aijaz, Faisal; Krijgsman, Brandon

    2010-01-01

    We present the case of a 67-year-old male with mesenteric venous thrombosis resulting in mesenteric angina, where early diagnosis made a favourable outcome possible through prompt anticoagulation and bowel rest. Mesenteric venous thrombosis is a relatively rare but important cause of bowel ischaemia, as a delay in diagnosis is associated with high morbidity and mortality. Early diagnosis through computed tomography scanning and subsequent treatment resulted in resolution of the thrombus with ...

  12. Prospects of Jugular Venous Pulse Assessment

    Directory of Open Access Journals (Sweden)

    M D Bhattarai

    2010-09-01

    Full Text Available There is no controversy regarding the current clinical method of examination of waveform of jugular vein pulse. However there are limitations of clinical assessment of central venous pressure by jugular vein pressure measurement from the level of sternal angle. There are variations in the reported distances from sternal angle to right atrium as well as to upper limit of JVP. In erect position, anterior end of fourth intercostal space is at about the level of mid-right atrium. In patients with visible JVP at neck in erect position, measurement of CVP can be done more accurately directly from the anterior end of fourth intercostal space. For others, the position of mid-right atrium can be marked in lateral chest wall first in erect position at the mid-point of an anteroposterior line from anterior end of fourth intercostal space to back. Subsequently in reclining position, the vertical height of venous pressure can be measured from the horizontal plane of the midpoint marked at lateral chest wall to visible upper limit of JVP. Such measurement can be done in a more reliable way with venous pressure (VP manometer with its indicator rod at the horizontal plane of mid-right atrium and with its horizontal surface at upper limit of JVP. The venous pressure manometer can also be used to measure relatively less reliable upper limb venous pressure (ULVP, as indicated by the vertical distance at which veins of upper limb collapse, especially when JVP is not visualized due to subnormal CVP as in hypovolemia. Keywords: CVP, JVP, right atrium, sternal angle, upper limp venous pressure, venous pressure, venous pressure manometer

  13. Workplace Social System and Sustained Return-to-Work: A Study of Supervisor and Co-worker Supportiveness and Injury Reaction.

    Science.gov (United States)

    Jetha, Arif; LaMontagne, Anthony D; Lilley, Rebbecca; Hogg-Johnson, Sheilah; Sim, Malcolm; Smith, Peter

    2017-08-31

    Objective To examine the impact of the social workplace system on sustained return-to-work (SRTW). Methods A random sample of workers' compensation claimants was recruited to complete a survey following claim acceptance (baseline), and 6 months later (time 2). SRTW, at baseline and time 2, was classified as those reporting being back at work for >28 days. Co-worker and supervisor support were assessed using five and seven items, respectively, and total scores were produced. A list of potential supervisory and co-worker reactions were presented to participants who were asked whether the reaction applied to them; response were coded as positive or non-positive. Demographic and injury characteristics, and work context factors were collected. Baseline and at time 2 multivariable models were conducted to examine the impact of supervisory and coworker support and injury reaction on SRTW. Results 551 (baseline) and 403 (time 2) participants from the overall cohort met study eligibility criteria. At baseline, 59% of all participants indicated SRTW; 70% reported SRTW at time 2. Participants reported moderate support from their supervisor (mean = 8.5 ± 3.9; median = 8.2; range = 5-15) and co-workers (mean = 10.2 ± 4.5; median = 10.3; range = 5-25). Over half reported a positive supervisor (59%) or co-worker injury reaction (71%). Multivariable models found that a positive supervisor injury reaction was significantly associated with SRTW at baseline (OR 2.3; 95% CI 1.4-3.9) and time 2 (OR 1.6; 95% CI 1.1-2.3). Conclusions Promoting supervisor positivity towards an injured worker is an important organizational work disability management strategy.

  14. MR findings of cerebral venous sinus thrombosis

    International Nuclear Information System (INIS)

    Lim, Myung Kwan; Chang, Kee Hyun; Han, Moon Hee; Choi, Choong Gom

    1994-01-01

    To describe MR findings of cerebral venous sinus thrombosis. We reviewed 11 MR images of six patients with cerebral venous sinus thrombosis. The MR images were retrospectively analyzed in terms of location and signal intensity of the thrombi, parenchymal lesions such as hemorrhage and edema, and changes in follow up study obtained in 4 patients. The thrombus in venous sinus was visualized on MRI in all six patients. The most frequently involved sites were superior sagittal sinus(n=4) and left transverse sinus(n=4). Signal intensity of the thrombus was isointense or hyperintense on both T1- and T2-weighted images with loss of normal signal void of the sinus on all sequences in all patients. Parenchymal lesion was patients in five of six cases, manifested as local hemorrhage in three and edema in three cases(one case overlapped). Local edema seen in three patients was completely resolved on follow up study of seven to 29 days intervals. It is concluded that iso- or high signal intensity with loss of signal void in venous sinus is virtually diagnostic of venous sinus thrombosis. If there are local parenchymal lesions such as hemorrhage and/or edema of unknown causes, cerebral venous sinus thrombosis should be included in differential diagnosis

  15. Needle-free powder lidocaine delivery system provides rapid effective analgesia for venipuncture or cannulation pain in children: randomized, double-blind Comparison of Venipuncture and Venous Cannulation Pain After Fast-Onset Needle-Free Powder Lidocaine or Placebo Treatment trial.

    Science.gov (United States)

    Zempsky, William T; Bean-Lijewski, Jolene; Kauffman, Ralph E; Koh, Jeffrey L; Malviya, Shobha V; Rose, John B; Richards, Patricia T; Gennevois, Daniel J

    2008-05-01

    The Comparison of Venipuncture and Venous Cannulation Pain After Fast-Onset Needle-Free Powder Lidocaine or Placebo Treatment trial was a randomized, single-dose, double-blind, phase 3 study investigating whether a needle-free powder lidocaine delivery system (a sterile, prefilled, disposable system that delivers lidocaine powder into the epidermis) produces effective local analgesia within 1 to 3 minutes for venipuncture and peripheral venous cannulation procedures in children. Pediatric patients (3-18 years of age) were randomly assigned to treatment with the needle-free powder lidocaine delivery system (0.5 mg of lidocaine and 21 +/- 1 bar of pressure; n = 292) or a sham placebo system (n = 287) at the antecubital fossa or the back of the hand 1 to 3 minutes before venipuncture or cannulation. All patients rated the administration comfort of the needle-free systems and the pain of the subsequent venous access procedures with the Wong-Baker Faces Pain Rating Scale (from 0 to 5). Patients 8 to 18 years of age also provided self-reports with a visual analog scale, and parents provided observational visual analog scale scores for their child's venous access pain. Safety also was assessed. Immediately after administration, mean Wong-Baker Faces scale scores were 0.54 and 0.24 in the active system and sham placebo system groups, respectively. After venipuncture or cannulation, mean Wong-Baker Faces scale scores were 1.77 +/- 0.09 and 2.10 +/- 0.09 and mean visual analog scale scores were 22.62 +/- 1.80 mm and 31.97 +/- 1.82 mm in the active system and sham placebo system groups, respectively. Parents' assessments of their child's procedural pain were also lower in the active system group (21.35 +/- 1.43 vs 28.67 +/- 1.66). Treatment-related adverse events were generally mild and resolved without sequelae. Erythema and petechiae were more frequent in the active system group. The needle-free powder lidocaine delivery system was well tolerated and produced significant

  16. Return on Investment Analysis of Health Experts onLine at Portsmouth: A 2-Year Review of the Navy's Newest Teleconsultation System.

    Science.gov (United States)

    Lin, Andrew H; Welstead, Bethany L; Morey, Brittany L; Mahnke, C Becket; Cole, Jacob H; Johnston, Michael G

    2017-05-01

    Health Experts onLine at Portsmouth (HELP) is a web-based teleconsultation system launched in June 2014 to facilitate communication between specialists at Naval Medical Center Portsmouth and providers assigned to both the fleet forces and primary care clinics across the eastern United States, Europe, and the Middle East. Specialist consultations through the HELP system purport to improve access to care for patients who otherwise might be referred to the civilian network or medically evacuated (MEDEVACed) to Naval Medical Center Portsmouth for specialized care. If HELP-facilitated communications help avoid civilian referrals or MEDEVACs, the associated costs of that care should be reduced. We evaluated cost savings associated with prevented MEDEVACs by analyzing both tangible savings (prevented costs of flights, per diems, and consults) and intangible savings (reduced lost productivity time). We compared these savings to the costs of maintaining and utilizing the HELP system: startup costs, administrative costs, and provider time costs. We used patient and provider data from the HELP database to evaluate clinical consult cases. Before this analysis, a panel of 3 physicians associated with HELP reviewed each consult to determine whether a case qualified as a prevented MEDEVAC. Data from the Military Health System (MHS) Management and Analysis Reporting Tool and the MHS Data Repository were used to estimate costs associated with provider time, patient time, and direct care medical encounters. The HELP program delivered measurable, positive returns on investment (ROIs) between June 2014 and December 2015. In that time frame, 559 consult cases occurred in the HELP system. Of the 559 total consult cases, 50 consults prevented MEDEVACs. Incorporating only tangible savings, HELP produced an 80% ROI on the basis of prevented medical evacuations; the addition of intangible savings such as reduced lost productivity increased the ROI to 250%. The dollar values of these savings

  17. Incidence of deep venous thrombosis and stratification of risk groups in a university hospital vascular surgery unit

    Directory of Open Access Journals (Sweden)

    Alberto Okuhara

    2015-06-01

    Full Text Available BACKGROUND: There is a knowledge gap with relation to the true incidence of deep vein thrombosis among patients undergoing vascular surgery procedures in Brazil. This study is designed to support the implementation of a surveillance system to control the quality of venous thromboembolism prophylaxis in our country. Investigations in specific institutions have determined the true incidence of deep vein thrombosis and identified risk groups, to enable measures to be taken to ensure adequate prophylaxis and treatment to prevent the condition.OBJECTIVE: To study the incidence of deep venous thrombosis in patients admitted to hospital for non-venous vascular surgery procedures and stratify them into risk groups.METHOD: This was a cross-sectional observational study that evaluated 202 patients from a university hospital vascular surgery clinic between March 2011 and July 2012. The incidence of deep venous thrombosis was determined using vascular ultrasound examinations and the Caprini scale.RESULTS: The mean incidence of deep venous thrombosis in vascular surgery patients was 8.5%. The frequency distribution of patients by venous thromboembolism risk groups was as follows: 8.4% were considered low risk, 17.3% moderate risk, 29.7% high risk and 44.6% were classified as very high risk.CONCLUSION: The incidence of deep venous thrombosis in vascular surgery patients was 8.5%, which is similar to figures reported in the international literature. Most vascular surgery patients were stratified into the high and very high risk for deep venous thrombosis groups.

  18. Life-threatening Vesicular Bronchial Injury Requiring Veno-venous Extracorporeal Membrane Oxygenation Rescue in an Electronic Nicotine Delivery System User

    Directory of Open Access Journals (Sweden)

    Thomas Carter

    2017-07-01

    Full Text Available The use of electronic nicotine delivery systems (ENDS is increasing across the United States as tobacco bans increase and more people use these devices in an attempt to quit smoking. They are unregulated by the Food and Drug Administration, and there is significant concern that ENDS could produce several toxic byproducts. In this case a 35-year-old female presented to the emergency department with sudden-onset dyspnea. She denied current tobacco smoking, but she was a user of ENDS. When bronchoscopy was performed, an extensive pattern of suspected chemical injury was noted in her airways. She required transfer to a tertiary center where she required extracorporeal membranous oxygenation. Despite public opinion that ENDS are generally safe, or at least safer than tobacco smoking, contrary evidence is mounting. We postulate that her injuries were likely suffered secondary to use of an ENDS.

  19. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study

    International Nuclear Information System (INIS)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F.

    2000-01-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  20. Serum homocysteine is associated with the severity of primary chronic venous disease.

    Science.gov (United States)

    Smith, Ross K; Quigley, Frank; Tosenovsky, Patrik; Velu, Ramesh; Bradshaw, Barbara; Buettner, Petra; Golledge, Jonathan

    2016-07-01

    This study was conducted to assess whether serum homocysteine concentration was associated with the severity of primary chronic venous disease. Cross-sectional study. A total of 282 primary chronic venous disease patients were enrolled from outpatient vascular services. The severity of venous disease was graded using the Clinical Etiology Anatomy Pathophysiology classification system. The association of serum homocysteine concentration with advanced primary chronic venous disease (C4-6) was assessed using the Mann Whitney U test and logistic regression analysis. Median (interquartile range) serum homocysteine concentrations were 9.10 µM (7.55-10.75) and 10.40 µM (8.85-13.10) in patients with primary chronic venous disease classified by C1-3 (n = 209) and C4-6 (n = 73) grades, respectively, p homocysteine concentration was positively associated with clinical grade 4-6 after adjusting for other risk factors including age, diabetes, male sex, hypertension, recurrent varicose veins and stroke. Patients with serum homocysteine in the third (odds ratio, 2.76, 95% confidence interval, 1.01-7.54) and fourth (odds ratio 3.29, 95% confidence interval 1.15-9.43) quartiles were more likely to have grade C4-6 chronic venous disease than subjects with serum homocysteine in the first quartile. Serum homocysteine is positively associated with the severity of primary chronic venous disease and therefore could play a role in promoting chronic venous disease complications. © The Author(s) 2015.

  1. Prevalence of chronic cerebrospinal venous insufficiency in multiple sclerosis: a blinded sonographic evaluation.

    Science.gov (United States)

    Tromba, L; Blasi, S; Vestri, A; Kiltzanidi, D; Tartaglia, F; Redler, A

    2015-02-01

    To verify the prevalence of chronic cerebrospinal venous insufficiency in patients affected by different clinical forms of multiple sclerosis and in healthy subjects using the Zamboni ultrasound protocol combined with M-mode ultrasound examination. We enrolled 112 patients with multiple sclerosis and 67 healthy subjects from 20 to 67 years of age. All the patients underwent Duplex and color-Doppler sonography of the neck vessels, transcranial colour duplex sonography, M-mode study of the valve system and of venous abnormalities. Subjects were positive for chronic cerebrospinal venous insufficiency when at least two of five hemodynamic criteria of the Zamboni protocol were fulfilled. Chronic cerebrospinal venous insufficiency condition was further analyzed by a multivariate analysis including age, sex, disease duration, subtypes of multiple sclerosis and expanded disability status scale score as independent variables. No healthy subjects was positive for chronic cerebrospinal venous insufficiency, while in the sample of patients affected by multiple sclerosis the diagnosis was made in 59.8% of cases (p multiple sclerosis and chronic cerebrospinal venous insufficiency (respectively 54.4% and 76.1%, p present in healthy subjects but were detected in patients with multiple sclerosis. The positivity of the second criterion was associated with diagnosis of chronic cerebrospinal venous insufficiency in 100% of cases. The third criterion had a prevalence of 52.2% in the subgroup of chronic cerebrospinal venous insufficiency patients. It was positive in 36 multiple sclerosis patients and was associated with chronic cerebrospinal venous insufficiency diagnosis in all cases except one. The multivariate analysis showed that age, disease duration, sex, subtypes of multiple sclerosis and expanded disability status scale score were not considered predictors of this haemodynamic condition. Chronic cerebrospinal venous insufficiency is a haemodynamic condition strongly

  2. Fingertip Replantation With Palmar Venous Anastomoses in Children.

    Science.gov (United States)

    Wen, Gen; Xu, Jia; Chai, Yi-Min

    2017-06-01

    Fingertip amputation in children is difficult to manage using microsurgical replantation techniques and many salvage procedures have failed owing to the nonavailability of suitable veins for anastomosis in the fingertip. This study reviewed our experience of pediatric fingertip replantation involving palmar venous anastomoses and evaluated the clinical outcomes. From October 2008 to May 2013, 21 pediatric fingertips that had been completely amputated at or distal to the distal interphalangeal joint of the finger, or at or distal to the interphalangeal joint of the thumb were managed using complete replantation. One artery was anastomosed for revascularization with or without nerve repair, and a palmar venous anastomosis was performed to reestablish the outflow system. Twenty (95.2%) of the 21 fingertips survived. One replant involving an avulsion amputation of the left little finger failed, and the patient underwent stump cap-plasty. Excellent restoration of finger motion, pinch strength, and appearance was observed during the mean 39.9-month (range, 18-65 months) follow-up. The mean regained static 2-point discrimination sensation was 3.8 mm (range, 3.2-4.2 mm). All of the children and their families were satisfied with the surgical outcomes. Successful palmar venous anastomosis appears to promote the survival of replanted fingertips in children. Given that the procedure may simplify postoperative care, minimize complications, and achieve a high survival rate, it should be attempted if the technical expertise is available.

  3. Healing of chronic venous ulcer with topical sevoflurane.

    Science.gov (United States)

    Imbernon-Moya, Adrian; Ortiz-de Frutos, Francisco Javier; Sanjuan-Alvarez, Mónica; Portero-Sanchez, Isabel; Merinero-Palomares, Raúl; Alcazar, Victoria

    2017-12-01

    The present study assesses the efficacy and safety of topical sevoflurane in chronic venous ulcers and its impact on analgesia and healing. This retrospective study included 30 patients older than 65 years with painful refractory chronic venous ulcers. Patients were treated with topical sevoflurane prior to the usual ulcer cleaning every 2 days for a period of 1 month. Treatment was initiated with a saline solution, followed by direct irrigation of 1 ml of liquid sevoflurane over the wound size, which was measured as cm 2 . Sevoflurane had a fast, intense and long-lasting analgesic effect. Latency time ranged from 2 to 7 minutes (3·9 ± 1·5 minutes), and duration varied from 8 to 18 hours (12 ± 2·9). The mean ulcer size was 8·4 ± 9·7 cm 2 . There was a progressive decrease in size in all patients, with a mean size of 4·2 ± 5·4 cm 2 at the end of the study. There were no adverse systemic effects. Local adverse effects were mild and transient, including pruritus, erythema and heat. Topical sevoflurane is a new, efficient and safe therapeutic alternative in painful chronic venous ulcers, refractory to usual analgesic treatment. It can improve the ulcer-healing process that shortens the cicatrisation period. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  4. Secondary venous aneurysm following intravenous drug abuse: A case report

    Directory of Open Access Journals (Sweden)

    Marković Miroslav

    2016-01-01

    Full Text Available Introduction. Venous aneurysm (VA is a rare condition that can be presented in both superficial and deep venous system. Secondary VAs as well as pseudoaneurysms are usually caused by external spontaneous or iatrogenic trauma. They are often misdiagnosed and inadequately treated. Complications include thrombosis, phlebitis, eventual pulmonary embolism and rupture. Case report. We presented a case of secondary VA of the great saphenous vein developed in a young addict following chronic intravenous drug application in the groin region. Aneurysm required urgent surgical treatment due to bleeding complication as it was previously misdiagnosed for hematoma (or abscess and punctuated by a general surgeon. Complete resection of VA with successful preservation of continuity of the great saphenous vein was performed. Postoperative course was uneventful. Regular venous flow through the great saphenous vein was confirmed on control ultrasound examination. Conclusion. VAs are uncommon, among them secondary VA being extremely rare. In cases with a significant diameter or threatening complications surgical treatment is recommended. [Projekat Ministarstva nauke Republike Srbije, br. ON175008 i br. III41007

  5. No agreement of mixed venous and central venous saturation in sepsis, independent of sepsis origin

    NARCIS (Netherlands)

    van Beest, Paul A.; van Ingen, Jan; Boerma, E. Christiaan; Holman, Nicole D.; Groen, Henk; Koopmans, Matty; Spronk, Peter E.; Kuiper, Michael A.

    2010-01-01

    Controversy remains regarding the relationship between central venous saturation (ScvO(2)) and mixed venous saturation (SvO(2)) and their use and interchangeability in patients with sepsis or septic shock. We tested the hypothesis that ScvO(2) does not reliably predict SvO(2) in sepsis. Additionally

  6. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated

  7. Imaging Diagnosis of Splanchnic Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    S. Rajesh

    2015-01-01

    Full Text Available Splanchnic vein thrombosis (SVT is a broad term that includes Budd-Chiari syndrome and occlusion of veins that constitute the portal venous system. Due to the common risk factors involved in the pathogenesis of these clinically distinct disorders, concurrent involvement of two different regions is quite common. In acute and subacute SVT, the symptoms may overlap with a variety of other abdominal emergencies while in chronic SVT, the extent of portal hypertension and its attendant complications determine the clinical course. As a result, clinical diagnosis is often difficult and is frequently reliant on imaging. Tremendous improvements in vascular imaging in recent years have ensured that this once rare entity is being increasingly detected. Treatment of acute SVT requires immediate anticoagulation. Transcatheter thrombolysis or transjugular intrahepatic portosystemic shunt is used in the event of clinical deterioration. In cases with peritonitis, immediate laparotomy and bowel resection may be required for irreversible bowel ischemia. In chronic SVT, the underlying cause should be identified and treated. The imaging manifestations of the clinical syndromes resulting from SVT are comprehensively discussed here along with a brief review of the relevant clinical features and therapeutic approach.

  8. The 'successful' return

    DEFF Research Database (Denmark)

    Olwig, Karen Fog

    2012-01-01

    Research on female migrant caregivers has tended to focus upon the emotional and social problems they encounter working abroad, given women’s traditional role as caregivers for their own families. This article analyses how Caribbean women who have returned after a period abroad as domestic workers...... inscribe their migration experiences within the gendered narrative of the good relative who migrates to help the family left behind and therefore deserves social recognition in the community of origin. It argues that this narrative allows the women to both affirm and reinterpret local family and gender...

  9. Venous injury in abusive head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Arabinda K. [Nemours A. I. duPont Hospital for Children, Department of Radiology, Wilmington, DE (United States); Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B. [Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Dias, Mark S. [Hershey Medical Center, Department of Neurosurgery, Hershey, PA (United States)

    2015-11-15

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  10. Venous injury in abusive head trauma

    International Nuclear Information System (INIS)

    Choudhary, Arabinda K.; Bradford, Ray; Thamburaj, K.; Boal, Danielle K.B.; Dias, Mark S.

    2015-01-01

    Abusive head trauma (AHT) is an important cause of serious brain injury in infants and young children who have characteristic clinical and imaging findings that are discordant with the clinical history provided. Recent attention has focused on abnormalities of the cranial venous sinuses and cortical veins, both on MRI and at autopsy. Although many have interpreted these to be secondary to the AHT, some have recently argued that these venous abnormalities represent primary cortical sinus and venous thrombosis that leads secondarily to subdural hemorrhage and secondary brain injury. Direct trauma to the veins and sinuses has been reported at autopsy in AHT, but there has been no systematic study of venous abnormalities in cases of AHT. The purpose of this study was to define the incidence and characteristics of venous and sinus abnormalities in AHT. We included all children <36 months of age who were diagnosed with abusive head trauma between 2001 and 2012 and who had MRI and magnetic resonance (MR) venography as part of their diagnostic workup. We analyzed age, gender and clinical findings. MRI and MR venography were analyzed independently by two neuroradiologists with a focus on abnormalities involving the intracranial veins and venous sinuses. A total of 45 children were included. The median age was 3 months (range 15 days to 31 months) and 28 were boys (62%). Clinical findings included retinal hemorrhage in 71% and extracranial fractures in 55%. CT or MRI demonstrated subdural hemorrhage in 41 (91%); none had subdural effusions. In 31 cases (69%) MR venography demonstrated mass effect on the venous sinuses or cortical draining veins, with either displacement or partial or complete effacement of the venous structures from an adjacent subdural hematoma or brain swelling. We also describe the lollipop sign, which represents direct trauma to the cortical bridging veins and was present in 20/45 (44%) children. Evidence of displacement or compression of cortical veins

  11. Bilateral catheter-directed thrombolysis in a patient with deep venous thrombosis caused by a hypoplastic inferior vena cava

    NARCIS (Netherlands)

    Sloot, S.; Van Nierop, J.; Kootstra, J. J.; Wittens, C.; Fritschy, W. M.

    Introduction Deep venous thrombosis treatment using catheter-directed thrombolysis is advocated over systemic thrombolysis because it reduces bleeding complications. With the development of a catheter that combines ultrasound vibrations and the local delivering of thrombolytics, new and safer

  12. Use of the Diffusion of Innovation Model in venous ulcers by specialized professionals

    Directory of Open Access Journals (Sweden)

    Eline Lima Borges

    Full Text Available ABSTRACT Objective: To analyze the influence of the evidence and of the opinion of peers on the decisions of specialists regarding the agreement with recommendations for prevention and treatment of venous ulcer. Methods: This is a quasi-experimental study with two interventions: provision of studies with the evidence of the recommendations and provision of the opinion of peers, with sample of 73 specialized doctors and nurses. Delphi technique was used in the search for agreement, with three rounds. Results: The participants evaluated 82 recommendations organized into eight domains: evaluation of patient and wound; documentation of clinical findings; care with the wound and surrounding skin; indication of dressing; use of antibiotics; improvement of venous return and prevention of recurrence; referrals of patients; and professional training. The interventions resulted in statistically significant changes in four domains. Conclusion: The interventions were able to change the opinion of participants, leading them to agreement regarding the recommendations, regardless of the level of evidence.

  13. Analysis of Social Return on Investment in two systems of support for people with severe disabilities: personal assistance and residential service. A case study

    Directory of Open Access Journals (Sweden)

    Agustín Huete García

    2014-06-01

    Full Text Available At present, there are several alternatives to support daily life of people with disabilities, which require different resources: human, institutional, technical, material, financial, etc. In addition, these alternatives involve different impacts on both the life of people with disabilites and their immediate environment. This paper presents a case study that compares an user of personal assistance services of the Program for Independent Living (PAVI with an user of a residential service. The study method used is based on the approach of Social Return on Investment (SROI. It also specifies the selection of cases, the partners consulted to gather concepts and values, data collection, variables and formulas for calculating and monetization. Despite its limited scope, it is possible to draw conclusions about the social return on investment in a “standard profile” receiving personal assistance services compared with a “standard profile” in a residential service.

  14. The Return to Foreign Aid

    DEFF Research Database (Denmark)

    Dalgaard, Carl-Johan Lars; Hansen, Henrik

    2017-01-01

    We estimate the average rate of return on investments financed by aid and by domestic resource mobilisation, using aggregate data. Both returns are expected to vary across countries and time. Consequently we develop a correlated random coefficients model to estimate the average returns. Across...... different estimators and two different data sources for GDP and investment our findings are remarkably robust; the average gross return on ‘aid investments’ is about 20 per cent. This is in accord with micro estimates of the economic rate of return on aid projects and with aggregate estimates of the rate...

  15. Cerebral venous sinus thrombosis on MRI: A case series analysis

    Directory of Open Access Journals (Sweden)

    Sanjay M Khaladkar

    2014-01-01

    Full Text Available Background: Cerebral venous sinus thrombosis (CVST is a rare form of stroke seen in young and middle aged group, especially in women due to thrombus of dural venous sinuses and can cause acute neurological deterioration with increased morbidity and mortality if not diagnosed in early stage. Neurological deficit occurs due to focal or diffuse cerebral edema and venous non-hemorrhagic or hemorrhagic infarct. Aim and Objectives: To assess/evaluate the role of Magnetic Resonance Imaging (MRI and Magnetic Resonance Venography (MRV as an imaging modality for early diagnosis of CVST and to study patterns of venous thrombosis, in detecting changes in brain parenchyma and residual effects of CVST using MRI. Materials and Methods: Retrospective descriptive analysis of 40 patients of CVST diagnosed on MRI brain and MRV was done. Results: 29/40 (72.5% were males and 11/40 (27.5% were females. Most of the patients were in the age group of 21-40 years (23/40-57.5%. Most of the patients 16/40 (40% presented within 7 days. No definite cause of CVST was found in 24 (60% patients in spite of detailed history. In 36/40 (90% of cases major sinuses were involved, deep venous system were involved in 7/40 (17.5% cases, superficial cortical vein was involved in 1/40 (2.5% cases. Analysis of stage of thrombus (acute, subacute, chronic was done based on its appearance on T1 and T2WI. 31/40 (77.5% patients showed complete absence of flow on MRV, while 9/40 (22.5% cases showed partial flow on MR venogram. Brain parenchyma was normal in 20/40 (50% patients while 6/40 (15% cases had non-hemorrhagic infarct and 14/40 (35% patients presented with hemorrhagic infarct. Conclusion: Our study concluded that MRI brain with MRV is sensitive in diagnosing both direct signs (evidence of thrombus inside the affected veins and indirect signs (parenchymal changes of CVST and their follow up.

  16. Accelerated myelination associated with venous congestion

    Energy Technology Data Exchange (ETDEWEB)

    Porto, L.; Yan, B.; Zanella, F.E.; Lanfermann, H. [Klinikum der Johann Wolfgang Goethe-Universitaet, Neuroradiology Department, Institut fuer Neuroradiologie, Frankfurt am Main (Germany); Kieslich, M. [Klinikum der Johann Wolfgang Goethe-Universitaet, Neuroradiology Department, Institut fuer Neuroradiologie, Frankfurt am Main (Germany); Neuropediatric Department, Frankfurt am Main (Germany)

    2006-04-15

    Magnetic resonance imaging is currently the gold standard in the assessment of brain myelination. The normal pattern of brain myelination conforms to a fixed chronological sequence. Focal accelerated myelination is a usual pathological state and previously has only been associated with Sturge-Weber syndrome. The purpose of our study is to describe alternate causes for accelerated myelination. We retrospectively reviewed serial MR scans, MR angiography, conventional angiography and the clinical progress of three children with accelerated myelination. Two patients with accelerated myelination had an underlying cerebral sinovenous thrombosis. The third patient had Sturge-Weber syndrome. Our study strongly suggests that cerebral venous thrombosis with the consequent restriction of venous outflow could be a key factor in the induction of accelerated myelination. We recommend that in patients with accelerated myelination, the search for an underlying etiology should include careful evaluation of the intracranial vascular pathology, especially cerebral venous thrombosis. (orig.)

  17. The Essentials of Parathyroid Hormone Venous Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [NYU Langone Medical Center, Department of Radiology, NYU School of Medicine (United States); Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology (United States); Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu [Beth Israel Deaconess Medical Center, Department of Interventional Radiology (United States); Oklu, Rahmi, E-mail: oklu.rahmi@mayo.edu [Mayo Clinic, Department of Interventional Radiology (United States); Deipolyi, Amy, E-mail: deipolya@mskcc.org [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States)

    2017-01-15

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

  18. Central venous obstruction in the thorax

    International Nuclear Information System (INIS)

    Collin, G.; Jones, R.G.; Willis, A.P.

    2015-01-01

    Central venous stenosis and occlusion can occur secondary to a spectrum of conditions ranging from aggressive malignancy to benign extrinsic anatomical compression in otherwise healthy individuals. Irrespective of aetiology, significant morbidity in the acute setting and long term can occur unless prompt accurate diagnosis and appropriate management is initiated, the radiologist being central to both. The present review will provide radiologists with a thorough illustration and explanation of the range of central venous conditions in the thorax (including deep vein thrombosis, thoracic outlet syndrome, haemodialysis, and malignancy related causes), the salient imaging findings and interventional management using case examples from the authors' practice. - Highlights: • We show a range of causes of central venous disease in the thorax. • We provide information about different imaging and management strategies. • We show several cases with successes and complications of endovascular management

  19. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  20. Return to space

    Science.gov (United States)

    1989-08-01

    This video documents the preparations for Shuttle Flight STS-26 with Shuttle Discovery, NASA's return to manned space flight after the Challenger disaster. Footage and descriptions document such changes to the new Shuttle as new joints, improved insulation, and added O-rings to the solid rocket boosters; new safety hardware and procedures such as parachute and sidewire evacuations during liftoff, and new pressure suits; modified landing gear, brakes, and nose wheel steering, as well as a modified landing runway. Also profiled are the 5 member crew of all veteran Shuttle astronauts, the TDRS 3 Satellite to be released from the cargo bay in orbit, and 11 commercial and student experiments to be performed during the mission.

  1. Clinical features and diagnosis of venous thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Hirsh, J.; Hull, R.D.; Raskob, G.E.

    1986-12-01

    The clinical diagnosis of venous thrombosis is inaccurate because the clinical findings are both insensitive and nonspecific. The sensitivity of clinical diagnosis is low because many potentially dangerous venous thrombi are clinically silent. The specificity of clinical diagnosis is low because the symptoms or signs of venous thrombosis all can be caused by nonthrombotic disorders. A current approach to the diagnosis of clinically suspected venous thrombosis favors the use of impedance plethysmography over Doppler ultrasonography as the main test for this disorder. This is because impedance plethysmography is precise and objective, whereas the interpretation of Doppler ultrasonography is subjective and requires considerable skill and experience to form reliable diagnoses. The use of serial impedance plethysmography has been evaluated recently in a prospective study. The rationale of repeated impedance plethysmography evaluation is based on the premise that calf vein thrombi are only clinically important when they extend into the proximal veins, at which point detection with impedance plethysmography is possible. Therefore, by performing repeated examinations with impedance plethysmography in patients with clinically suspected venous thrombosis, it is possible to identify patients with extending calf vein thrombosis who can be treated appropriately. Impedance plethysmography is performed immediately on referral; if it is positive in the absence of clinical conditions that are known to produce falsely positive results, the diagnosis of venous thrombosis is established, and the patient is treated accordingly. If the result of the initial impedance plethysmography evaluation is negative, anticoagulant therapy is withheld, and impedance plethysmography is repeated the following day, again on day 5 to 7 and on day 10 to 14. 87 references.

  2. [Superficial venous thrombosis. A state of art].

    Science.gov (United States)

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception

  3. The perspectives of adults with venous leg ulcers on exercise: an exploratory study.

    Science.gov (United States)

    O'Brien, J; Finlayson, K; Kerr, G; Edwards, H

    2014-10-01

    Exercise has the potential to offer a range of health benefits in addition to improving healing outcomes for people with venous leg ulcers (VLUs). However, despite evidence-based recommendations, most of these individuals do not engage in regular exercise. The aim of this study was to gain an understanding of the perspectives of adults with VLUs, in relation to exercise. This was a qualitative design using semi-structured interviews and discussions. Ten participants with venous leg ulceration volunteered to participate. Recruitment was through a specialist wound clinic. Verbatim data were collected by an experienced moderator using a semi-structured guide. Data saturation was reached after three group discussions and two interviews. A random selection of transcripts was sent back to the participants for verification. Thematic content analysis was used to determine major themes and categories. Two transcripts were independently analysed, categories and themes independently developed, cross checked and found comparable. Remaining transcripts were analysed using the developed categories and codes. Regardless of their current exercise routine, participants reported exercising before venous leg ulceration and expressed an interest in either becoming active or maintaining an active lifestyle. Overall, four themes emerged from the findings: i) participant understanding of the relationship between chronic venous insufficiency and exercise patterns; ii) fear of harm impacts upon positive beliefs and attitudes to exercise; iii) perceived factors limit exercise; and iv) structured management facilitates exercise. The value of exercise in improving outcomes in VLUs lies in its capacity to promote venous return and reduce the risk of secondary conditions in this population. Despite motivation and interest in being exercise active, people with VLUs report many obstacles. Further exploration of mechanisms that assist this patient population and promote understanding about

  4. Management of Peripheral and Truncal Venous Injuries

    Directory of Open Access Journals (Sweden)

    Triantafillos G. Giannakopoulos

    2017-08-01

    Full Text Available Civilian injuries are increasing according to the World Health Organization, and this is attributed mainly to road traffic accidents and urban interpersonal violence. Vascular injuries are common in these scenarios and are associated with high morbidity and mortality rates. Associated peripheral venous trauma is less likely to lead to death and controversy remains whether ligation or repair should be the primary approach. Conversely, non-compressible truncal venous insult can be lethal due to exsanguination, thus a high index of suspicion is crucial. Operative management is demanding with fair results but recent endovascular adjuncts demonstrate promising results and seem to be the way forward for these serious conditions.

  5. [Lethal portal venous gas after cardiopulmonary arrest].

    Science.gov (United States)

    Thomachot, L; Arnal, J M; Vialet, R; Albanèse, J; Martin, C

    1998-01-01

    We report the case of a 51-year-old patient admitted after a transient cardiorespiratory arrest. The abdominal CT scan revealed the presence of hepatic portal venous gas. At laparotomy, a diffuse mesenteric ischaemia was diagnosed. The patient died from multiple organ failure in the subsequent hours. Necrotic bowel is associated with hepatic portal venous gas in 50% of the cases and the current mortality rate is 85%. Gas originates either through intestinal transmucosal passage, either by intraportal bacterial gas production, or through both mechanisms.

  6. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  7. Differences in peripheral arterial and venous hemorheologic parameters

    NARCIS (Netherlands)

    Mokken, F. C.; van der Waart, F. J.; Henny, C. P.; Goedhart, P. T.; Gelb, A. W.

    1996-01-01

    To evaluate the comparability of hemorheologic parameters in arterial and venous blood, we measured hematocrit, whole blood viscosity, plasma viscosity, erythrocyte deformability, erythrocyte aggregation, and erythrocyte indices in both arterial and venous blood from 20 consecutive patients

  8. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R(2) = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway...

  9. Pregnancy-related venous thromboembolism and risk of occult cancer

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Veres, Katalin; Horváth-Puhó, Erzsébet

    2017-01-01

    The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk.......The cancer risk during the first year after a pregnancy-related venous thromboembolism episode is higher than expected. An aggressive search for cancer in women with pregnancy-related venous thromboembolism is probably not warranted, due to low absolute risk....

  10. Three-dimensional colour Doppler of ductus venous agenesis in the first trimester

    OpenAIRE

    Divya Singh; Ladbans Kaur

    2016-01-01

    Ductus venosus (DV) has a pivotal role in the fetal circulation. It serves as a conduit connecting the fetal umbilical and portal venous system with the inferior vena cava (IVC). The absence of DV is an uncommon anomaly. In case of agenesis of DV, the umbilical vein joins the fetal systemic venous circulation via the intra-hepatic or extra-hepatic route. We report a case of absent DV with associated anomaly diagnosed in the first trimester using three-dimensional (3D) colour Doppler.

  11. Three-dimensional colour Doppler of ductus venous agenesis in the first trimester

    Directory of Open Access Journals (Sweden)

    Divya Singh

    2016-11-01

    Full Text Available Ductus venosus (DV has a pivotal role in the fetal circulation. It serves as a conduit connecting the fetal umbilical and portal venous system with the inferior vena cava (IVC. The absence of DV is an uncommon anomaly. In case of agenesis of DV, the umbilical vein joins the fetal systemic venous circulation via the intra-hepatic or extra-hepatic route. We report a case of absent DV with associated anomaly diagnosed in the first trimester using three-dimensional (3D colour Doppler.

  12. Relationship between neighborhood socioeconomic status and venous thromboembolism: results from a population-based study.

    Science.gov (United States)

    Kort, D; van Rein, N; van der Meer, F J M; Vermaas, H W; Wiersma, N; Cannegieter, S C; Lijfering, W M

    2017-12-01

    Essentials Literature on socioeconomic status (SES) and incidence of venous thromboembolism (VTE) is scarce. We assessed neighborhood SES with VTE risk in a population of over 1.4 million inhabitants. Higher neighborhood SES was associated with lower incidence of VTE. These findings are helpful to inform policy and resource allocation in health systems. Background The association between socioeconomic status and arterial cardiovascular disease is well established. However, despite its high burden of disability-adjusted life years, little research has been carried out to determine whether socioeconomic status is associated with venous thromboembolism. Objective To determine if neighborhood socioeconomic status is associated with venous thromboembolism in a population-based study from the Netherlands. Methods We identified all patients aged 15 years and older with a first event of venous thromboembolism from inhabitants who lived in the urban districts of The Hague, Leiden and Utrecht in the Netherlands in 2008-2012. Neighborhood socioeconomic status was based on the status score, which combines educational level, income and unemployment on a four-digit postal code level. Incidence rate ratios of venous thromboembolism were calculated for different levels of neighborhood socioeconomic status, with adjustments for age and sex. Results A total of 7373 patients with a first venous thromboembolism (median age 61 years; 50% deep vein thrombosis) were identified among more than 1.4 million inhabitants. Higher neighborhood SES was associated with lower incidence of VTE. In the two highest status score groups (i.e. the 95-99th and > 99th percentile), the adjusted incidence rate ratios were 0.91 (95% confidence interval [CI], 0.84-1.00) and 0.80 (95% CI, 0.69-0.93), respectively, compared with the reference status score group (i.e. 30-70th percentile). Conclusions High neighborhood socioeconomic status is associated with a lower risk of first venous thromboembolism. © 2017

  13. Endovenous ablation of incompetent perforating veins is effective treatment for recalcitrant venous ulcers.

    Science.gov (United States)

    Lawrence, Peter F; Alktaifi, Ali; Rigberg, David; DeRubertis, Brian; Gelabert, Hugh; Jimenez, Juan Carlos

    2011-09-01

    Endovenous closure of incompetent saphenous veins has been reported to facilitate venous ulcer healing; however, there is little information about the effectiveness of perforator ablation (PA) in healing recalcitrant venous ulcers. We report our experience with PA with venous ulcers unresponsive to prolonged compression therapy. Patients with nonhealing venous ulcers of >3 months' duration underwent duplex ultrasound to assess their lower extremity venous system for incompetence of superficial, perforating, and deep veins. Patients who had either no saphenous incompetence or persistent ulcers after saphenous ablation underwent PA of incompetent perforating veins >3 mm that demonstrated reflux; initial treatment was performed on the perforator vein adjacent to the ulcer with additional incompetent veins treated if ulcer healing failed. Seventy-five ulcers with 86 associated incompetent perforating veins were treated with PA in 45 patients with CEAP 6 recalcitrant venous ulcers. Treated incompetent perforator veins were located in the medial ankle (61%), calf (37%), and lateral ankle (2%). Initial success of PA, assessed by postprocedure duplex ultrasound, was 58%; repeat ablation was 90% successful and 71% had eventual successful perforator closure. No complications (skin necrosis, infection, or nerve injury) occurred. Failure of ulcer healing with successful perforator closure occurred in 10% and was due to intercurrent illness, patient noncompliance, and patient death due to unrelated causes. Of patients who healed their ulcers, the healing occurred at a mean of 138 days; an average PA of 1.5 incompetent veins per ulcer was required for healing. Ninety percent of ulcers healed when at least one perforator was closed; no ulcer healed without at least one perforator being closed. This experience demonstrates both the feasibility and effectiveness of PA for a selected group of patients with venous ulcers who fail conventional therapy with compression. Copyright

  14. ANTIMICROBIOLOGICAL EFFECTS OF NEW NATURAL ANTISEPTIC FORMULATION ON NON-INFECTED VENOUS LEG ULCER: PILOT STUDY

    Directory of Open Access Journals (Sweden)

    Ivana Binić

    2011-09-01

    Full Text Available Venous leg ulcers represent a significant public health problem that will increase as the population ages. Numerous herbs and their extracts are potentially conducive to wound healing, including the ability to serve as antimicrobial, antifungal, astringent etc. The aim of the study was to establish the in-vivo antimicrobial effects of herbal hydrogel formulation DermaplantG. The major components of the DermaplantG were the extracts of Allii bulbus, Hyperici herba and extract of Calendulae flos. A total of 12 patients with non-infected venous leg ulcers were treated twice daily, for 5 weeks, with new hydrogel formulation. All ulcers showed clinical signs of contamination or colonization without signs of systemic infection. Premoistening the swab with sterile saline was considered when the surface of the wound was dry. The tip of the swab was rolled on its side in a zigzag pattern for at least one full rotation. Standard methods for isolation and identification of aerobic and anaerobic bacteria were used. On baseline assessment, a large number of different types of bacteria were detected in all venous leg ulcers. S. aureus and P. aeruginosa were isolated from almost all controls.On baseline, mixed bacterial flora (50% was isolated in six venous leg ulcers (five ulcers with S. aureus-P. aeruginosa and one ulcer with E.coli-Enterobacter spp-P.aeruginosa. At the end of the treatment in DermaplantG group in 8 venous ulcers were detected S. aureus (66.66% and P. aeruginosa (16.66%, and one venous leg ulcers was detected as sterile (8.33%. The number of different types of isolated bacterial species decreased significantly (P<0.05 after the use of DermaplantG herbal preparations. Therapy in DermaplantG group was administered without any side effects.The preliminary results of this pilot study demonstrate potential antimicrobial effects of herbal therapy on non-infected venous leg ulcers.

  15. Safety and effectiveness of central venous catheters usage in newborns intensive care unit

    Directory of Open Access Journals (Sweden)

    І. А. Anikin

    2016-10-01

    Full Text Available To date, ensuring long-term venous access in newborns is an actual problem of intensive therapy. Central venous catheters, which implantable peripherally (PICC-line, are widely used as a medium-term vascular access in newborns in the department of intensive care. Objective - To study the incidence of complications associated with the use of central venous access in newborns intensive care department. Materials and methods. Characteristics and safety of various central venous access in newborns were studied. The study is retrospective, with a quantitative analysis of the results. The safe practice PICC-line and CVCSI accesses groups were compared, revealed complications in 361 newborns, who received complex intensive therapy in connection with diseases of the perinatal period, were analyzed. Results. Due to the fact that some babies accessed re-established catheters, the total number of observations was 395. We took the complications of catheter-related infection, taking into account the instructions of the Center for Disease Control and Prevention (theUSA. We searched the number of mechanical and infectious complications, which were associated with venous catheters. The number of catheter occlusion, against the background of infusion therapy was not significantly different in the groups, and the obstruction of the catheter by thrombus was the most frequent complication in the PICC-line group. CVCSIs revealed fairly large number of system thrombosis of the superior vena cava, and a great number of infectious complications. KAI Number of cases in the group of newborns with PICC-line was almost 4 times less than in infants with CVCSI venous access. Cases of death in patients did not associate with venous access, despite the fact that the total amount of complications in CVCSI group were significantly higher. Conclusion. The received results have showen that peripherally implanted catheters have a higher level of security and ease of installation

  16. Cerebral venous sinus thrombosis presenting as subdural haematoma

    International Nuclear Information System (INIS)

    Singh, S.; Kumar, S.; Joseph, M.; Gnanamuthu, C.; Alexander, M.

    2005-01-01

    The authors report a 39-year-old woman who presented with intermittent, excruciating nuchal and occipital headache. Magnetic resonance imaging and magnetic resonance angiography scans showed bilateral subdural haematomas with veno-occlusive disease of the superficial and deep venous systems. There were bridging collaterals with scalp veins, bleeds from which could explain the subdural haematoma. There was acute on chronic veno-occlusive disease with an acute rise in intracranial pressure and a bleed from the vein of Galen Copyright (2005) Blackwell Publishing Asia Pty Ltd

  17. Incidence of venous leg ulcer healing and recurrence after treatment with endovenous laser ablation.

    Science.gov (United States)

    Marston, William A; Crowner, Jason; Kouri, Ana; Kalbaugh, Corey A

    2017-07-01

    The Effect of Surgery and Compression on Healing and Recurrence (ESCHAR) trial previously reported that patients with venous leg ulcers treated with saphenous stripping experienced a significantly reduced incidence of ulcer recurrence compared with patients treated with compression therapy. Most patients with leg ulcers and saphenous insufficiency are currently treated with endovenous thermal ablation (EVTA), but little information is available on the long-term results after EVTA in Clinical, Etiology, Anatomy, and Pathophysiology (CEAP) clinical class 5 (C5) and class 6 (C6) patients. We retrospectively reviewed all CEAP C5 or C6 patients treated with EVTA to define the incidence of ulcer healing and recurrence. Patients with active ulcers were managed weekly in a comprehensive wound center until healed. After healing, patients were treated with compression stockings and returned at 6-month intervals for follow-up. Time to healing and time to ulcer recurrence were determined by Kaplan-Meier survival analysis. Risk factors were assessed to determine their association with ulcer recurrence. EVTA of the great saphenous vein (n = 146), small saphenous vein (n = 20), or both (n = 7) was performed on 173 limbs with active (n = 72) or healed (n = 101) ulcers. Deep venous insufficiency was present in 54 cases (31.2%). Concomitant phlebectomy was performed in 59 limbs (34%). Median follow-up time was 25.2 months after EVTA. Venous ulcers healed after EVTA in 57% of cases at 3 months, 74% at 6 months, and 78% at 12 months. Ulcers recurred in 9% of patients at 1 year after EVTA, 20% at 2 years, and 29% at 3 years of follow-up. Ulcers recurred significantly more often in patients with deep venous insufficiency and in patients who did not undergo phlebectomy of associated varicose veins at the time of EVTA. Ulcers recurred in a minority of CEAP clinical C5 and C6 patients after EVTA of the saphenous veins. Ulcer recurrence was less frequent in patients without

  18. Misplaced left internal jugular venous catheter with an exceptional ...

    African Journals Online (AJOL)

    Large numbers of central venous catheters (CVCs) are placed each year in the intensive care units and misplacement occurs frequently. Many critically ill patients require central venous catheterization for multiple and varied reasons. Internal jugular vein (IJV) catheter is one of the most frequent central venous catheters in ...

  19. The recalcitrant venous leg ulcer - A never ending story?

    NARCIS (Netherlands)

    S.W.I. Reeder (Suzan); M.B. Maessen-Visch (Birgitte); S.I. Langendoen; K.P. de Roos; H.A.M. Neumann (Martino)

    2013-01-01

    textabstractIntroduction: In general, four particular causes of recalcitrant venous leg ulcers may be distinguished. These are foot pump insufficiency, chronic venous compartment syndrome and non-re-canalized popliteal vein thrombosis. The fourth cause of recalcitrant venous leg ulcers is

  20. Venous thrombosis during pregnancy: leg and trimester of presentation

    NARCIS (Netherlands)

    Ginsberg, J. S.; Brill-Edwards, P.; Burrows, R. F.; Bona, R.; Prandoni, P.; Büller, H. R.; Lensing, A.

    1992-01-01

    In order to determine the relative frequencies of left and right leg venous thrombosis during pregnancy and the frequencies of venous thrombosis during the three trimesters, a cohort study of 60 consecutive patients with a first episode of venous thrombosis during pregnancy was performed.

  1. Mechanochemical endovenous ablation and new frontiers in venous intervention

    NARCIS (Netherlands)

    Boersma, D

    2017-01-01

    Venous insufficiency of the lower extremities is a common condition and related to various symptoms, including venous ulcers. The effect of venous insufficiency on patients’ health-related quality of life is substantial and comparable with other chronic diseases such as arthritis, diabetes, and

  2. 21 CFR 870.1140 - Venous blood pressure manometer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Venous blood pressure manometer. 870.1140 Section 870.1140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  3. Metastatic Carcinoma of Unknown Primary Presenting as Jugular Venous Thrombosis

    Directory of Open Access Journals (Sweden)

    Prince Cheriyan Modayil

    2009-01-01

    Full Text Available Jugular venous thrombosis is unusual and is associated with central venous catheterisation, intravenous drug abuse and head and neck sepsis. It is rarely associated with malignancy. We report a case of metastatic carcinoma of unknown primary in a forty year old female which presented with jugular venous thrombosis. The discussion includes investigation and treatment options for this condition.

  4. Diagnostics of defeats of venous collectors of brain

    International Nuclear Information System (INIS)

    Timofeeva, T.V.; Polunina, I.S.; Shcherbakova, E.Ya.; Kuldakova, S.V.

    1997-01-01

    Comparative data of transcranial ultrasonic dopplerography (170 patients) and radionuclidous antroscintigraphy (124), received during diagnostics of defects of venous collectors of brain are analyzed. Five variants of defeats of venous collectors (cross, sigmoid, internal of jugular of jugular vein), but also unpaired sine (direct, confluent) are described. Received results permit to reveal interrelation of infringements of venous outflow and increase of intracranial pressure

  5. The return of religion

    Directory of Open Access Journals (Sweden)

    S. Griffioen

    2011-06-01

    Full Text Available Religion is back in Philosophy as a respectable subject. Part 1 first charts what MacIntyre, Taylor and Derrida have meant in this regard. Subsequently, it turns to the Enlightenment to determine what constituted the breakthrough. It is found that even where the Enlightenment gave maximum room to religion i.e. as a civic religion and as “religion of the heart” it still excluded a constitutive relation to a transcendent revelation. Part 2 centres on the religion-faith distinction in reformational philosophy. Similar to the Enlightenment, religion is understood as part of human nature. However, human nature itself is conceived as intrinsically religious and depending for its light on revelation. Secondly, “religion” in this context also encompasses idols and religious substitutes. Thus, it directs attention to shopping malls, football stadiums, health policy, et cetera, as possible contexts of a return of religion. Examples show that this has become a popular approach. However, most of the publications surveyed fail to distinguish between an “analogical” and a “pistically qualified” use of religion, and are open to exaggerations (the shopping mall and football stadiums as temples, etc.. At this junction, the relevance is shown of the religion-faith distinction as well as of Elaine Botha’s theory of metaphors. The epilogue offers an integration of parts one and two.

  6. Competition, Innovation and Increasing Returns

    OpenAIRE

    George B. Richardson

    1996-01-01

    This paper concerns the operation of competition in the presence of a high rate of innovation and increasing returns. Given free competition there is likely to exist, in this case, a tendency towards what may be called ‘dynamic equilibrium’, a tendency, that is to say, for the rate of investment in product development to rise or fall towards the level at which this investment yields only a normal return. Thus, competition, increasing returns and innovation may co-exist.

  7. Small juxtacortical hemorrhages in cerebral venous thrombosis

    NARCIS (Netherlands)

    Coutinho, Jonathan M.; van den Berg, René; Zuurbier, Susanna M.; VanBavel, Ed; Troost, Dirk; Majoie, Charles B.; Stam, Jan

    2014-01-01

    Intracerebral hemorrhages (ICHs) are common in patients with cerebral venous thrombosis (CVT). We examined whether small juxtacortical hemorrhages (JCHs) are characteristic for CVT and studied their radiological and pathological properties. We identified all patients with CVT and an ICH at baseline

  8. Clinical overview of venous thromboembolism | Schellack | South ...

    African Journals Online (AJOL)

    Venous thromboembolism (VTE) encompasses two vascular conditions that are of significant importance, namely deep vein thrombosis (DVT) and pulmonary embolism (PE). DVT is also the most common cause of PE. Medical and surgical patients, and individuals who are at increased risk of developing VTE through a ...

  9. Venous thromboembolism: awareness and practice of ...

    African Journals Online (AJOL)

    However, the high level of thromboprophylaxis practice appears doubtful because only a few of these physicians carry out VTE risk assessment for their patients as well as follow clinical guidelines on VTE thromboprophylaxis. Key words: Venous thromboembolism, deep vein thrombosis, pulmonary embolism, risk factor, ...

  10. Venous thromboembolism: awareness and practice of ...

    African Journals Online (AJOL)

    MJP

    Report from Centre for Disease Control and. Prevention (CDC) puts VTE related mortality in. ABSTRACT. Background: Venous thromboembolism (VTE) is a major public health challenge globally due to its high morbidity and mortality. The condition is often asymptomatic and under diagnosed due to lack of awareness on ...

  11. Travel and venous thrombosis: a systematic review

    NARCIS (Netherlands)

    Kuipers, S.; Schreijer, A. J. M.; Cannegieter, S. C.; Bueller, H. R.; Rosendaal, F. R.; Middeldorp, S.

    2007-01-01

    In the past decade, numerous publications on the association between venous thrombosis (VT) and travel have been published. Relative and absolute risks of VT after travel, and particularly after travel by air, have been studied in case-control and observational follow-up studies, whereas the effect

  12. Urethro-venous intravasation during urethrography

    African Journals Online (AJOL)

    J.M. Ratkal

    Abstract. Retrograde urethrography is a procedure used to evaluate urethral strictures. Urethro-venous intravasation, rarely seen during retrograde urethrography, can result in bacteremia, adverse reactions to contrast agents, renal failure and even pulmonary embolism. We report one such case of a male patient who ...

  13. Venous function after pharmacomechanical thrombolysis for ...

    African Journals Online (AJOL)

    2017-08-29

    Aug 29, 2017 ... Subsequent chronic venous insufficiency (CVI) because of post-thrombotic syndrome (PTS) is associated with increased morbidity and poses a significant health care burden.1 PTS significantly impacts health-related quality of life (QoL) after DVT. It is characterised by a chronic feeling of limb heaviness ...

  14. Venous thromboembolism: Risk profile and management of ...

    African Journals Online (AJOL)

    Objectives. This study aims to describe the venous thromboembolism (VTE) risk profile of women undergoing elective gynaecological surgery in a tertiary hospital and to audit the VTE prophylaxis prescribed. Methods. One hundred and nine women who underwent elective gynaecological surgery at Kalafong Provincial ...

  15. Scintiangiographic diagnosis of acute mesenteric venous thrombosis

    International Nuclear Information System (INIS)

    Smith, R.W.; Selby, J.B.

    1979-01-01

    Scintiangiographic findings of prolonged mesenteric activity in a case of acute mesenteric thrombosis is described and 105 cases with abdominal scintiangiography are reviewed. Usual peak mesenteric blush occurred 5 to 15 sec after initial visualization of the aorta. Normal clearance of this activity was 15 to 30 sec. Future cases should confirm the importance of this observation in early diagnosis of mesenteric venous thrombosis

  16. VENOUS THROMBOEMBOLISM PROPHYLAXIS – THE OTHER ...

    African Journals Online (AJOL)

    Background: There are no local guidelines for prophylaxis against Venous Thrombo-Embolism (VTE). In the absence of any guidelines, most of the information available has been provided mainly by the pharmaceutical industry which is an interested party. There have been publications in local journals that lean more on ...

  17. Thermodilution-determined Internal Jugular Venous Flow

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Widmer, Mario; Hilty, Matthias P

    2017-01-01

    PURPOSE: Cerebral blood flow (CBF) increases ~20% during whole body exercise although a Kety-Schmidt-determined CBF is reported to remain stable; a discrepancy that could reflect evaluation of arterial vs. internal jugular venous (IJV) flow and/or that CBF is influenced by posture. Here we test...

  18. Knowledge, attitude and practice of venous thromboembolism ...

    African Journals Online (AJOL)

    USER

    We aimed to assess the knowledge, attitude and practice of prophylaxis in venous thromboembolism among medical doctors in Usmanu Danfodiyo University Teaching Hospital,. Sokoto, North-West Nigeria. Methodology: The knowledge, attitude and practice of VTE prophylaxis among medical doctors was assessed using ...

  19. Multiple cerebral venous sinus thrombosis: Case report

    African Journals Online (AJOL)

    (1). Headache was present in our patient. This symptom, in association with vomiting is a feature of intracranial hypertension. Normal cerebro-spinal fluid flow patterns have the final common pathway as the reabsorption by the arachnoid granulations and flow into the venous sinuses (6). Thrombosis within the sinuses block.

  20. Venous infraction of developmental venous anomaly: A case report with perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Youn; Kim, Hye Jeong; Hyun, Su Jeong; Kim, Hee Yeong; Kim, Han Myun; Hwang, Ji Young; Hong, Hye Suk; Woo, Ji Young; Yang, Ik [Dept. of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Kim, Eun Soo [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2017-06-15

    Developmental venous anomaly (DVA) is a common congenital venous malformation characterized by dilated medullary veins in caput medusa configuration and a draining vein. Despite the high incidence of DVAs, they are benign anatomic variations and rarely cause symptoms. Here, we report computed tomography and magnetic resonance imaging findings with perfusion images of acute infarction from underlying DVA in a 63-year-old female patient who presented with acute onset of neurologic symptoms and recovered without any neurologic deficit.

  1. PUC fast track nips returns

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the first of what it says will be annual cost-of-capital proceedings to set returns on equity and rates of return on rate base for electric utilities, the California Public Utilities Commission (PUC) lowered from 1989 levels the 1990 returns on common equity (ROE) and rates of return (ROR) for the state's four major investor-owned electric utilities. Under this fast-track procedure, by May 8 of every year, utilities will have to file an application for rate adjustments that reflect their projected costs of capital for the following year

  2. The return to foreign aid

    DEFF Research Database (Denmark)

    Dalgaard, Carl-Johan Lars; Hansen, Henrik

    We investigate the marginal productivity of investment across countries. The aim is to estimate the return on investments financed by foreign aid and by domestic resource mobilization, using aggregate data. Both returns are expected to vary across countries and time. Consequently we develop...... a correlated random coefficients model, to estimate the average aggregate return on ‘aid investments’ and ‘domestic investments’. Across different estimators and two different sources for GDP and investment data our findings are remarkably robust; the average gross return on ‘aid investments’ is about 20 per...

  3. Decommissioning: returning the Niederaichbach site to nature

    International Nuclear Information System (INIS)

    Krieger, F.; Obst, J.

    1985-01-01

    The German Niederaichbach plant is expected to be the first reactor in Western Europe to be returned to a green-field site. A remote-controlled cutting and handling system, developed to carry out the decommissioning is described. The dismantling procedure and the project status are outlined. (author)

  4. A sonographic quantitative cutoff value of cerebral venous outflow in neurologic diseases: a blinded study of 115 subjects.

    Science.gov (United States)

    Monti, L; Menci, E; Piu, P; Leonini, S; Arrigucci, U; Bellini, M; Zandonella, A; Galluzzi, P; Casasco, A

    2014-07-01

    The autonomic nervous system maintains constant cerebral venous blood outflow in changing positions. Alterations in cerebral autoregulation can be revealed by postural changes at quantitative color Doppler sonography. The aim of this study was to reach an optimal cutoff value of the difference between the cerebral venous blood outflow in the supine and seated positions that can discriminate healthy controls from patients with multiple sclerosis and those with other neurologic diseases and to evaluate its specificity, sensitivity, and diagnostic accuracy. One hundred fifteen subjects (54 with MS, 31 healthy controls, 30 with other neurologic diseases) underwent a blinded quantitative color Doppler sonography evaluation of cerebral venous blood outflow in the supine and sitting positions. An optimal difference value between the supine and sitting positions of the cerebral venous blood outflow cutoff value was sought. The difference value between supine and sitting positions of the cerebral venous blood outflow was ≤ 503.24 in 38/54 (70.37%) patients with MS, 9/31 (29.03%) healthy controls, and 13/30 (43.33%) subjects with other neurological diseases. A difference value between supine and sitting positions of the cerebral venous blood outflow at a 503.24 cutoff reached a sensitivity at 70.37%, a 70.96% specificity, a 80.85% positive predictive value, and a 57.89% negative predictive value; the quantitative color Doppler sonography parameters yielded significant differences. The difference value between supine and sitting positions of cerebral venous blood outflow ≤ 503.24 assessed the significant difference between MS versus other neurological diseases. Alteration of cerebral venous blood outflow discriminated MS versus other neurologic diseases and MS versus healthy controls. The difference value between supine and sitting positions of cerebral venous blood outflow ≤ 503.24 was statistically associated with MS. © 2014 by American Journal of Neuroradiology.

  5. Return probability: Exponential versus Gaussian decay

    Energy Technology Data Exchange (ETDEWEB)

    Izrailev, F.M. [Instituto de Fisica, BUAP, Apdo. Postal J-48, 72570 Puebla (Mexico)]. E-mail: izrailev@sirio.ifuap.buap.mx; Castaneda-Mendoza, A. [Instituto de Fisica, BUAP, Apdo. Postal J-48, 72570 Puebla (Mexico)

    2006-02-13

    We analyze, both analytically and numerically, the time-dependence of the return probability in closed systems of interacting particles. Main attention is paid to the interplay between two regimes, one of which is characterized by the Gaussian decay of the return probability, and another one is the well-known regime of the exponential decay. Our analytical estimates are confirmed by the numerical data obtained for two models with random interaction. In view of these results, we also briefly discuss the dynamical model which was recently proposed for the implementation of a quantum computation.

  6. Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study.

    Science.gov (United States)

    Mitchell, S J; Willcox, T; Gorman, D F

    1997-09-01

    We have previously shown significant bubble formation in Medtronic Maxima hard-shell venous reservoirs (HSVRs). In the present study, we not only investigated the mechanism of this bubble formation, but also the extent of bubble clearance by membrane oxygenators and arterial line filters. In addition, we also compared the performance of five HSVRs with respect to bubble formation and venous air filtration. Salvaged clinical CPB circuits containing different HSVRs were studied by downstream Doppler monitoring under fixed flow-decreasing volume, fixed volume-increasing flow, and entrained venous air conditions. Bubbles formed in the Medtronic Maxima top entry HSVR at volumes below 800 ml and flows above 3.5 l min-1, and were incompletely removed by a membrane oxygenator and arterial line filter. Decreased bubbling was seen when the reservoir atmosphere was flushed with CO2, suggesting that these bubbles formed in a fountain at the venous inflow. The Medtronic Maxima Forte HSVR formed significantly fewer bubbles at low volumes, and filtered venous air effectively. Negligible bubble formation occurred in the Sorin, Terumo, or Baxter reservoirs. The minimum recommended operating volume for the Medtronic Maxima top entry reservoir should be reset at 600 ml and this device should always be used with an arterial filter. Bubble formation is substantially reduced in the new Medtronic Maxima Forte HSVR and this device is a good filter for venous air.

  7. Spectrum of Visual Impairment in Cerebral Venous Thrombosis: Importance of Tailoring Therapies Based on Pathophysiology.

    Science.gov (United States)

    Aaron, Sanjith; Arthur, Anupriya; Prabakhar, A T; Mannam, Pavitra; Shyamkumar, N K; Mani, Sunithi; Mathew, Vivek; Peter, Jeyanthi; Sivadasan, Ajith; Alexander, Anika; Karthik, M; Benjamin, Rohith Ninan; Alexander, Mathew

    2017-01-01

    Visual impairment can complicate cerebral venous thrombosis (CVT). Here, we describe the various pathophysiological mechanisms and treatments available. A retrospective chart review of all patients treated for CVT in a large quaternary teaching hospital was done, and cases with visual impairment due to CVT were identified. The various mechanisms causing visual impairment in CVT were (1) raised intracranial pressure (ICP) caused by venous thrombosis without venous infarcts resulting in a benign intracranial hypertension-like presentation of CVT, (2) venous infarcts involving the occipital cortex, (3) raised ICP following the development of a secondary dural arteriovenous (AV) fistula, and (4) arterial occipital infarcts due to posterior cerebral artery compression secondary to herniation in large venous infarcts. Apart from using systemic anticoagulants to attempt recanalization and drugs with carbonic anhydrase inhibitor activity to reduce the ICPs, treatment modalities employed to save vision were (1) recanalization by local thrombolysis, stenting, or mechanical devices; (2) cerebrospinal fluid diversion procedures such as theco-periotoneal shunting; (3) optic nerve sheath fenestration; and (4) specific treatment for conditions such as dural AV fistula occurring as a late complication. CVT can cause visual impairment through different pathophysiological mechanisms. Depending on the mechanism, treatment strategies need to be tailored. Furthermore, very close monitoring is needed both in the acute and in the follow-up period, as new pathophysiological mechanisms can arise, compromising the vision. This may require a different treatment approach. Literature on this aspect of CVT is lacking.

  8. Venous Adventitial Cystic Disease: A Review of 45 Cases Treated Since 1963

    Directory of Open Access Journals (Sweden)

    Corey Bascone

    2016-01-01

    Full Text Available Purpose. To review and identify the most accurate ways of diagnosing and treating adventitial cystic disease (ACD of the venous system. Methods. Cases of ACD were collected through three popular medical databases, including PubMed, Cochrane, OVID, and MEDLINE. After reviewing the literature, the sites of occurrence of 323 cases of adventitial cystic disease were documented, and all cases of arterial ACD were excluded. The clinical features, treatment, and subsequent course of 45 cases of venous ACD are included in this paper. Results. After reviewing all 45 cases of venous ACD , we have confirmed that the most common vessel affected is the common femoral vein, which reproduces the most common symptom of venous ACD: asymmetric lower extremity swelling worsening over time. Conclusion. Venous ACD most commonly affects the common femoral vein. When unilateral leg swelling occurs with or without a noticeable mass, ACD should be considered. It is best confirmed with CT venography and the treatment of choice is transluminal cyst evacuation and excision.

  9. Venous malformations: MR imaging features that predict skin burns after percutaneous alcohol embolization procedures

    International Nuclear Information System (INIS)

    Fayad, Laura M.; Hazirolan, Tuncay; Carrino, John A.; Bluemke, David A.; Mitchell, Sally

    2008-01-01

    To examine the value of magnetic resonance (MR) imaging for predicting the occurrence of skin burns in patients with venous malformations who undergo percutaneous alcohol embolization was the objective of the study. Pre-procedural MR imaging at 1.5 T from 40 patients with venous malformations who had undergone percutaneous alcohol embolization was retrospectively reviewed by two observers for these features: anatomic location, definition (well-defined or ill-defined), and the presence of skin, subcutaneous tissue, muscle, tendon, bone, joint, and deep venous system involvement. One observer recorded the length of skin involvement and volume of the malformation. Univariate and multivariate analysis tests were used to determine whether an association between the occurrence of skin burns and MR imaging features existed. The anatomic locations of the venous malformations were the lower extremity (20 out of 40), upper extremity (11 out of 40), trunk (four out of 40), head/neck (three out of 40) and pelvis (two out of 40). Of the 40 subjects, 15% (six out of 40) experienced skin burns. There was a significant association between the absence of muscle involvement (p=0.0198) as well as the length of skin involvement (p=0.027), with the occurrence of skin burns. Malformation size and all other features were not significantly associated with skin burns. Skin burns in patients with venous malformations treated with alcohol embolization are associated with the length of skin involvement and with the absence of deeper tissue involvement, as depicted on MR imaging. (orig.)

  10. Morphologic changes of cerebral veins in hypertensive rats: venous collagenosis is associated with hypertension.

    Science.gov (United States)

    Zhou, Min; Mao, Lijuan; Wang, Ying; Wang, Qian; Yang, Zhiyun; Li, Shurong; Li, Ling

    2015-03-01

    The aims of this study were to determine whether arterial hypertension could affect the venous system of brain and to find out the consequent pathologic changes of cerebral veins. Thirty male Sprague-Dawley rats were divided into 2 groups: a sham-clipped group and a stroke-prone renovascular hypertensive rat group. A 2-kidney 2-clip rat model was used to induce renovascular hypertension in the hypertensive group. Systolic blood pressure was measured by tail cuff once each week. Susceptibility-weighted imaging (SWI) was performed at 12, 16, and 20 weeks after surgery. All the rats were sacrificed after the SWI examination at 20 weeks after surgery. The brains were extracted and embedded in paraffin for histologic examination. Masson trichrome staining was performed to identify venous collagenosis. The sham group demonstrated less prominence of cerebral veins compared with hypertensive groups (P veins on SWI as a sign of venous hypertension and the thickened cerebral venous walls (venous collagenosis), which may play a role in cerebral ischemia and/or infarction, are both consequences of long-term hypertension in hypertensive rats. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Measuring return to work.

    Science.gov (United States)

    Wasiak, Radoslaw; Young, Amanda E; Roessler, Richard T; McPherson, Kathryn M; van Poppel, Mireille N M; Anema, Johannes R

    2007-12-01

    It is argued that one of the factors limiting the understanding of return to work (RTW) following work disability is the use of measurement tools that do not capture a complete picture of workers' RTW experiences. To facilitate the investigation of RTW, the current authors proposed a developmental conceptualization of RTW, which argues for an expanded awareness that encompasses four phases: off work, work reintegration, work maintenance and advancement. This paper reports on work undertaken with the aim of operationalizing the conceptualization. A review of the RTW and related literature, with databases searched including PubMed, EconLit, and PsycInfo. We began by extracting details of RTW instruments used by previous researchers. We then interpreted these within the context of the phases of RTW. Using the International Classification of Functioning, Disability, and Health (ICF) to inform our thinking and coding structure, we conceptualized phase-based RTW outcomes and categorized them as 'tasks and actions', 'contextual' or 'process driven'. Iteratively, we reviewed existing instruments for their use as measures of RTW. Where gaps in instrumentation were found, the wider vocational and career assessment literature was searched for instruments that could be adapted for use in RTW research. Results indicate that, although numerous research instruments have been used to assess RTW, within the scientific literature some important dimensions of RTW lack instrumentation. In particular, we found that outcomes such as goal setting, motivation, expectation, job seeking, work maintenance, and career advancement require operationalization. Amongst the outcomes had been operationalized, we found considerable variation in conceptual development and application. The lack of consistency and comprehensiveness of RTW measurement is one of the factors compromising the advancement of the field of RTW research. It is suggested that a more complete and psychometrically sound array of

  12. Pharmacological adjuncts for chronic venous ulcer healing: a systematic review.

    Science.gov (United States)

    Varatharajan, Lavanya; Thapar, Ankur; Lane, Tristan; Munster, Alex B; Davies, Alun Huw

    2016-06-01

    The aim of this study was to systematically review the current evidence and determine whether there is a clinical benefit for using pharmacological agents as adjunctive treatment for chronic venous ulcers. A systematic review of the MEDLINE and EMBASE (from 1 January 1947 through 15 August 2013) and Cochrane databases (from inception through 15 August 2013) was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Inclusion criteria were all randomised controlled trials investigating pharmacological adjuncts for the treatment of venous ulcers with a minimum sample size of 20 patients for each treatment arm. Ten relevant articles were identified; one pilot randomised controlled trial and four Cochrane reviews were included. Pentoxifylline, aspirin, sulodexide, mesoglycan, flavonoids, thromboxane A2 antagonist (ifetroban), zinc, prostaglandin and prostacyclin analogues were the drugs reviewed. Pentoxifylline was found to be more effective than placebo in terms of complete ulcer healing or in causing a significant improvement (greater than 60% reduction in ulcer size) (RR 1.70, 95% CI 1.30 to 2.24). Aspirin and flavonoids show potential to be effective adjuncts but methodological shortcomings and issues with bias limit the validity of results from trials involving each of these drugs, respectively. There was no significant difference between placebo and Ifetroban and likewise pooled results from trials investigating sulodexide and zinc showed no benefit in comparison to placebo. Many systemic pharmacological agents have been investigated as adjuncts to venous ulcer healing; however, pentoxifylline (400 mg, three times a day) is currently the only drug that has promising evidence to support its use. Other compounds are in early stage research. © The Author(s) 2015.

  13. Intrahepatic arterioportal shunting and anomalous venous drainage: understanding the CT features in the liver

    International Nuclear Information System (INIS)

    Breen, David J.; Rutherford, Elizabeth E.; Stedman, Brian; Lee-Elliott, Catherine; Hacking, C. Nigel

    2004-01-01

    The increased use of high-contrast volume, arterial-phase studies of the liver has demonstrated the frequent occurrence of arterioportal shunts within both the cirrhotic and non-cirrhotic liver. This article sets out to explain the underlying microcirculatory mechanisms behind these commonly encountered altered perfusion states. Similarly, well-recognised portal perfusion defects occur around the perifalciform and perihilar liver and are largely caused by anomalous venous drainage via the paraumbilical and parabiliary venous systems. The underlying anatomy will be discussed and illustrated. These vascular anomalies are all caused by or result in diminished portal perfusion and are often manifest in the setting of portal venous thrombosis. The evolving concept of zonal re-perfusion following portal vein thrombosis will be discussed. (orig.)

  14. Impact of seasonal forecast use on agricultural income in a system with varying crop costs and returns: an empirically-grounded simulation

    Science.gov (United States)

    Gunda, T.; Bazuin, J. T.; Nay, J.; Yeung, K. L.

    2017-03-01

    Access to seasonal climate forecasts can benefit farmers by allowing them to make more informed decisions about their farming practices. However, it is unclear whether farmers realize these benefits when crop choices available to farmers have different and variable costs and returns; multiple countries have programs that incentivize production of certain crops while other crops are subject to market fluctuations. We hypothesize that the benefits of forecasts on farmer livelihoods will be moderated by the combined impact of differing crop economics and changing climate. Drawing upon methods and insights from both physical and social sciences, we develop a model of farmer decision-making to evaluate this hypothesis. The model dynamics are explored using empirical data from Sri Lanka; primary sources include survey and interview information as well as game-based experiments conducted with farmers in the field. Our simulations show that a farmer using seasonal forecasts has more diversified crop selections, which drive increases in average agricultural income. Increases in income are particularly notable under a drier climate scenario, when a farmer using seasonal forecasts is more likely to plant onions, a crop with higher possible returns. Our results indicate that, when water resources are scarce (i.e. drier climate scenario), farmer incomes could become stratified, potentially compounding existing disparities in farmers’ financial and technical abilities to use forecasts to inform their crop selections. This analysis highlights that while programs that promote production of certain crops may ensure food security in the short-term, the long-term implications of these dynamics need careful evaluation.

  15. Human radicular veins: regulation of venous reflux in the absence of valves.

    Science.gov (United States)

    van der Kuip, M; Hoogland, P V; Groen, R J

    1999-02-01

    In the literature it is generally assumed that venous reflux within the radicular veins is prevented by the presence of bicuspid valves and narrowing of the transdural part of these vessels. Recently, we performed a human cadaver study of the internal vertebral venous plexus. Surprisingly, a large number of radicular and perimedullary veins appeared to be filled with Araldite CY 221 mixture, after injection of this material into the vertebral venous system, implicating reflux via the radicular veins and suggesting insufficiency of the presumed anti-reflux mechanism. Therefore, it was decided to study the radicular veins in order to determine and to investigate the presence or absence of anti-reflux mechanisms within this system. The vertebral venous systems of ten fresh human cadavers, between 64 and 93 years of age, were injected with Araldite CY 221 mixture. After polymerization, all cadavers were dissected and the spinal nerve sheaths, including nerve roots, radicular veins and epidural veins, were excised as a whole. After macroscopical examination, serial sections (40 microm) were cut on a freezing microtome and stained in Von Gieson medium. Every third section was stained immunohistochemically with smooth muscle antigen (SMA), to visualize smooth muscle cells. In all cadavers, a number of intradural radicular veins was filled with Araldite. Employing microscopical examination, no bicuspid valves were found. However, four structures were encountered that might serve as ananti-reflux-mechanism: 1) intravenous dural folds, 2) meandrous configuration, and 3) narrowing of the radicular veins at the point of penetration of the dura mater, and 4) varying numbers of smooth muscle fibers in the walls of the intradural and extradural parts of the radicular veins. Reflux via the radicular veins seems to be a physiological phenomenon. Structural valves have not been encountered during this study. Intravenous dural folds, meandrous configuration and narrowing of the

  16. Supracardiac type total anomalous pulmonary venous connection (TAPVC) with oesophageal varices

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Ae; Lee, Hyoung Doo; Ban, Ji Eun; Jo, Min Jung [Pusan National University School of Medicine, Department of Paediatrics, Medical Research Institute, Pusan National University Hospital, Busan (Korea); Sung, Si Chan; Chang, Yun Hee [Pusan National University School of Medicine, Department of Thoracic and Cardiovascular Surgery, Medical Research Institute, Pusan National University Hospital, Busan (Korea); Choo, Ki Seok [Pusan National University School of Medicine, Department of Radiology, Medical Research Institute, Pusan National University Hospital, Busan (Korea)

    2008-10-15

    Oesophageal varices due to total anomalous pulmonary venous connection (TAPVC) is very rare. Additionally, the infradiaphragmatic type is the most common type of oesophageal varices due to TAPVC. Paraoesophageal varices due to stenosis of the vertical vein of supracardiac TAPVC has not previously been reported. We describe paraoesophageal varices developed as a result of a connection between the left lower pulmonary vein and the umbilicovitelline venous system because of stenosis of the proximal vertical vein in supracardiac type TAPVC in a 3-day-old female newborn who presented with general cyanosis, tachypnoea and dyspnoea. (orig.)

  17. Cerebral venous thrombosis: Update on clinical manifestations, diagnosis and management

    Directory of Open Access Journals (Sweden)

    Leys Didier

    2008-01-01

    Full Text Available Cerebral venous thrombosis (CVT has a wide spectrum of clinical manifestations that may mimic many other neurological disorders and lead to misdiagnoses. Headache is the most common symptom and may be associated with other symptoms or remain isolated. The other frequent manifestations are focal neurological deficits and diffuse encephalopathies with seizures. The key to the diagnosis is the imaging of the occluded vessel or of the intravascular thrombus, by a combination of magnetic resonance imaging (MRI and magnetic resonance venography (MRV. Causes and risk factors include medical, surgical and obstetrical causes of deep vein thrombosis, genetic and acquired prothrombotic disorders, cancer and hematological disorders, inflammatory systemic disorders, pregnancy and puerperium, infections and local causes such as tumors, arteriovenous malformations, trauma, central nervous system infections and local infections. The breakdown of causes differs in different parts of the world. A meta-analysis of the most recent prospectively collected series showed an overall 15% case-fatality or dependency rate. Heparin therapy is the standard therapy at the acute stage, followed by 3-6 months of oral anticoagulation. Patients with isolated intracranial hypertension may require a lumbar puncture to remove cerebrospinal fluid before starting heparin when they develop a papilloedema that may threaten the visual acuity or decompressive hemicraniectomy. Patients who develop seizures should receive antiepileptic drugs. Cerebral venous thrombosis - even pregnancy-related - should not contraindicate future pregnancies. The efficacy and safety of local thrombolysis and decompressive hemicraniectomy should be tested

  18. Biphasic threat to femoral head perfusion in abduction: arterial hypoperfusion and venous congestion

    Energy Technology Data Exchange (ETDEWEB)

    Yousefzadeh, David K. [Comer Children' s Hospital, Department of Radiology, Chicago, IL (United States); University of Chicago, Department of Radiology, Chicago, IL (United States); Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Johnson, Neil [Cincinnati Children' s Hospital, Department of Radiology, Cincinnati, OH (United States); Doerger, Kirk [Radiology Associates of Northern Kentucky, Crestview Hills, KY (United States); Sullivan, Christopher [University of Chicago, Department of Surgery, Chicago, IL (United States)

    2010-09-15

    Hip abduction can cause avascular necrosis (AVN) of the femoral head in infants. To compare the US perfusion pattern of femoral head cartilage in neutral position with that in different degrees and duration of abduction, testing the venous congestion theory of post-abduction ischemia. In 20 neonates, the Doppler flow characteristics of the posterosuperior (PS) branch of the femoral head cartilage feeding vessels were evaluated in neutral and at 30 , 45 , and 60 abduction. In three neonates the leg was held in 45-degree abduction and flow was assessed at 5, 10, and 15 min. Male/female ratio was 11/9 with a mean age of 1.86 {+-} 0.7 weeks. The peak systolic velocities (PSV) declined in all three degrees of abduction. After 15 min of 45-degree abduction, the mean PSV declined and showed an absent or reversed diastolic component and undetectable venous return. No perfusion was detected at 60-degree abduction. Abduction-induced femoral head ischemia is biphasic and degree- and duration-dependent. In phase I there is arterial hypoperfusion and in phase II there is venous congestion. A new pathogeneses for femoral head ischemia is offered. (orig.)

  19. Computed Tomograpy Venography diagnosis of iliocaval venous obstruction in advanced chronic venous insufficiency

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Rossi

    2014-12-01

    Full Text Available Objective:Iliocaval obstruction is associated with venous hypertension symptoms and may predispose to deep venous thrombosis (DVT. Ultrasonography may fail to achieve noninvasive diagnosis of these obstructions. The possibility of using Computed Tomography Venography (CTV for these diagnoses is under investigation.Methods:Patients with CVI graded at CEAP clinical classes 3 to 6 and previous treatment failure underwent evaluation with CTV. Percentage obstruction was rated by two independent examiners. Obstruction prevalence and its associations with risk factors and CEAP classification were analyzed.Results:A total of 112 limbs were prospectively evaluated. Mean patient age was 55.8 years and 75.4% were women. Obstructions involved the left lower limb in 71.8% of cases and 35.8% of patients reported a medical history of deep venous thrombosis. Overall, 57.1% of imaging studies demonstrated venous obstruction of at least 50% and 10.7% showed obstruction of >80%. The only risk factor that was found to be independently associated with a significantly higher incidence of >50% venous obstruction was a medical history of DVT (p=0.035 (Fisher's exact test. There was a positive relationship between clinical classification (CEAP and degree of venous obstruction in the limbs studied (Chi-square test for linear trend; p=0.011.Conclusion:Patients with advanced CVI are often affected by obstructions in the iliocaval venous territory and CTV is able to diagnose the degree of obstruction. There is a positive association between degree of obstruction and both previous history of DVT and severity of symptoms of CVI.

  20. Risk factors for venous thrombosis associated with peripherally inserted central venous catheters

    Science.gov (United States)

    Pan, Longfang; Zhao, Qianru; Yang, Xiangmei

    2014-01-01

    To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112