WorldWideScience

Sample records for systemic gentamicin levels

  1. Gentamicin concentration gradients in scala tympani perilymph following systemic applications.

    Science.gov (United States)

    Hahn, Hartmut; Salt, Alec N; Schumacher, Ulrike; Plontke, Stefan K

    2013-01-01

    It has been shown in prior studies that round window membrane (RWM) application of gentamicin produced a robust basal-apical concentration gradient in the perilymph of scala tympani (ST) with peak concentrations in the basal turn of ST. These gradients potentially contribute to the clinical efficacy and safety of intratympanic gentamicin applications for the treatment of Ménière's disease. The present study aimed to establish the distribution of gentamicin along ST perilymph after systemic applications. Gentamicin sulfate was applied intravenously in the amounts of 100, 300 and 600 mg/kg body weight (BW) over a period of 3 h or as a 300 mg/kg BW subcutaneous bolus injection. At 3 and 5 h after the start of the application perilymph of ST was aspirated from the cochlea apex of the right and left cochlea, respectively, and 10 sequential 1-µl perilymph samples from the apex of each cochlea were quantitatively analyzed using a fluorescence polarization immunoassay. In contrast to local RWM delivery, systemic application of gentamicin resulted in the highest perilymph levels in the apex of the cochlea with decreasing concentrations towards the basal regions of ST. The absolute gentamicin concentrations increased with the amount of drug applied and time before sampling. While it is likely that the basal-apical gradient measured after local drug applications to the round window niche is the result of the direct uptake of drugs into the perilymph of the ST, distribution by diffusion and a very low perilymph flow towards the cochlear apex, computer simulations suggested that the apical-basal gradient observed with these systemic applications can be explained by higher entry rates of gentamicin in the apex compared to the basal turns of the cochlea. It is also possible that gentamicin enters perilymph indirectly from the blood via the endolymph. In this case the faster kinetics in apical turns could be due to the smaller cross-sectional area of ST relative to endolymph in

  2. Incidence of high-level gentamicin resistance in enterococci at ...

    African Journals Online (AJOL)

    gentamicin resistance (HLGR) in enterococcal isolates at. Johannesburg Hospital. Design. Survey of laboratory isolates. Setting. Academic hospitals. Bacterial strains. Consecutive samples of enterococcaf isolates. ... that for severe infections, particularly endocarditis and meningitis, bactericidal antimicrobial therapy is ...

  3. The Role of Monitoring Gentamicin Levels in Patients with Gram-Negative Peritoneal Dialysis-Associated Peritonitis

    Science.gov (United States)

    Tang, Wen; Cho, Yeoungjee; Hawley, Carmel M.; Badve, Sunil V.; Johnson, David W.

    2014-01-01

    ♦ Background: There is limited available evidence regarding the role of monitoring serum gentamicin concentrations in peritoneal dialysis (PD) patients receiving this antimicrobial agent in gram-negative PD-associated peritonitis. ♦ Methods: Using data collected in all patients receiving PD at a single center who experienced a gram-negative peritonitis episode between 1 January 2005 and 31 December 2011, we investigated the relationship between measured serum gentamicin levels on day 2 following initial empiric antibiotic therapy and subsequent clinical outcomes of confirmed gram-negative peritonitis. ♦ Results: Serum gentamicin levels were performed on day 2 in 51 (77%) of 66 first gram-negative peritonitis episodes. Average serum gentamicin levels on day 2 were 1.83 ± 0.84 mg/L with levels exceeding 2 mg/L in 22 (43%) cases. The overall cure rate was 64%. No cases of ototoxicity were observed. Day-2 gentamicin levels were not significantly different between patients who did and did not have a complication or cure. Using multivariable logistic regression analysis, failure to cure peritonitis was not associated with either day-2 gentamicin level (adjusted odds ratio (OR) 0.96, 95% confidence interval (CI) 0.25 - 3.73) or continuation of gentamicin therapy beyond day 2 (OR 0.28, 0.02 - 3.56). The only exception was polymicrobial peritonitis, where day-2 gentamicin levels were significantly higher in episodes that were cured (2.06 ± 0.41 vs 1.29 ± 0.71, p = 0.01). In 17 (26%) patients receiving extended gentamicin therapy, day-5 gentamicin levels were not significantly related to peritonitis cure. ♦ Conclusion: Day-2 gentamicin levels did not predict gentamicin-related harm or efficacy during short-course gentamicin therapy for gram-negative PD-related peritonitis, except in cases of polymicrobial peritonitis, where higher levels were associated with cure. PMID:24385334

  4. Gentamicin pharmacokinetics in the chicken inner ear.

    Science.gov (United States)

    Bunting, Eric C; Park, Debra L; Durham, Dianne; Girod, Douglas A

    2004-06-01

    Avians have the unique ability to regenerate cochlear hair cells that are lost due to ototoxins or excessive noise. Many methodological techniques are available to damage the hair cells for subsequent scientific study. A recent method utilizes topical application of an ototoxic drug to the round window membrane. The current study examines the pharmacokinetics of gentamicin in the inner ear of chickens following topical application to the round window membrane or a single systemic high dose given intraperitoneally. Chickens were given gentamicin topically or systemically and survived for 1, 4, 12, 24, or 120 h (controls at 4 and 120 h). Serum and perilymph samples were obtained prior to sacrifice and measured for gentamicin levels. Results revealed higher levels of gentamicin in the perilymph of topically treated chickens than systemically treated chickens, with significant amounts of gentamicin still present in both at the latest survival time of 5 days. As expected, systemically treated chickens had much higher levels of gentamicin in the serum than topically treated chickens. Advantages and disadvantages to each method of drug administration are discussed.

  5. Effect of gentamicin and levels of ambient sound on hearing screening outcomes in the neonatal intensive care unit: A pilot study.

    Science.gov (United States)

    Garinis, Angela C; Liao, Selena; Cross, Campbell P; Galati, Johnathan; Middaugh, Jessica L; Mace, Jess C; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S

    2017-06-01

    Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2-15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. This was a prospective pilot outcomes study of 82 infants (4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p = 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify infants at-risk for ototoxicity. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Rapid colorimetric assay for gentamicin injection.

    Science.gov (United States)

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  7. Effect of rifampicin and gentamicin on Shiga toxin 2 expression level and the SOS response in Escherichia coli O104:H4.

    Science.gov (United States)

    Fadlallah, Sukayna M; Rahal, Elias A; Sabra, Ahmad; Kissoyan, Kohar A B; Matar, Ghassan M

    2015-01-01

    A novel pathotype, Shiga toxin-producing Escherichia coli O104:H4, was the cause of a severe outbreak that affected European countries, mainly Germany, in 2011. The effect of different regimens of rifampicin and gentamicin were evaluated to determine possible treatment modes for the novel strain, and to evaluate the SOS response and its effect on toxin release. Pulsed-field gel electrophoresis (PFGE) was performed on the novel E. coli O104:H4 pathotype and two pre-outbreak E. coli O104:H4 CDC strains. Transcript levels of the stx2 and recA gene (SOS response inducer) were evaluated using quantitative real-time reverse transcriptase polymerase chain reaction (qRT-PCR) in the novel E. coli O104:H4 samples subjected to different regimens of rifampicin and gentamicin. Consequently, reverse passive latex agglutination (RPLA) was used to determine the Stx2 titers in these samples. Western blot was performed to determine the LexA levels (SOS response repressor) in E. coli O104:H4. The efficacy of treatment with antimicrobial agents was assessed in BALB/c mice. The outbreak and pre-outbreak strains are closely related as shown by PFGE, which demonstrated slight genomic differences between the three strains. The transcription level of the stx2 gene in the new pathotype was 1.41- and 1.75-fold that of the 2009 EL-2050 and 2009 EL-2071 pre-outbreak strains, respectively. Moreover, the transcription level of the stx2 gene in the new pathotype was substantially decreased as a result of treatment with the different concentrations of the antimicrobial agents, but was enhanced when the antibiotics were administered at two subinhibitory levels. RPLA data were in accordance with the qRT-PCR results. E. coli O104:H4 exposed to gentamicin at both sub-minimum inhibitory concentration (MIC) levels led to high transcription levels of the recA gene and lack of expression of the LexA protein, implying that the SOS response was activated. Rifampicin at both sub-MIC levels resulted in low

  8. Gentamicin in Pseudomonas aeruginosa

    African Journals Online (AJOL)

    infections by Ps. aeruginosa is contra-indicated. In our study only 2,3 % of the Ps. aeruginosa strains were resistant to gentamicin (MIC 25 Ilg/ml). In view of the synergy reported for combined gentamicin and carbeni- cillin therapy," a combination of these two drugs may be recommended in the treatment of all Pseudomonas.

  9. Silica-Gentamicin Nanohybrids: Synthesis and Antimicrobial Action

    Directory of Open Access Journals (Sweden)

    Dina Ahmed Mosselhy

    2016-03-01

    Full Text Available Orthopedic applications commonly require the administration of systemic antibiotics. Gentamicin is one of the most commonly used aminoglycosides in the treatment and prophylaxis of infections associated with orthopedic applications, but gentamicin has a short half-life. However, silica nanoparticles (SiO2 NPs can be used as elegant carriers for antibiotics to prolong their release. Our goal is the preparation and characterization of SiO2-gentamicin nanohybrids for their potential antimicrobial administration in orthopedic applications. In vitro gentamicin release profile from the nanohybrids (gentamicin-conjugated SiO2 NPs prepared by the base-catalyzed precipitation exhibited fast release (21.4% during the first 24 h and further extension with 43.9% release during the five-day experiment. Antimicrobial studies of the SiO2-gentamicin nanohybrids versus native SiO2 NPs and free gentamicin were performed against Bacillus subtilis (B. subtilis, Pseudomonas fluorescens (P. fluorescens and Escherichia coli (E. coli. SiO2-gentamicin nanohybrids were most effective against B. subtilis. SiO2 NPs play no antimicrobial role. Parallel antimicrobial studies for the filter-sterilized gentamicin were performed to assess the effect of ultraviolet (UV-irradiation on gentamicin. In summary, the initial fast gentamicin release fits the need for high concentration of antibiotics after orthopedic surgical interventions. Moreover, the extended release justifies the promising antimicrobial administration of the nanohybrids in bone applications.

  10. Comparison of product drying performance in molded and serum tubing vials using gentamicin sulfate as a model system.

    Science.gov (United States)

    Hibler, Susanne; Wagner, Christophe; Gieseler, Henning

    2012-01-01

    In a previous study, heat transfer coefficients of different 10 mL tubing and molded vials were determined gravimetrically via sublimation tests with pure water. Contrary to "conventional wisdom", only small differences in K(v) values between tubing and molded vials were found in the pressure range relevant for pharmaceutical freeze-drying. In order to investigate the impact of these relatively small differences on the primary drying time of an actual product, freeze-drying experiments with 5% gentamicin sulfate solution as a model system were performed at 68, 100 and 200 mTorr. The primary drying times of the API in recently developed molded (EasyLyo™), tubing (TopLyo™) and polymer vials (TopPac™) were compared. At 68 and 100 mTorr the primary drying time of the drug in the glass vials only differed by 3% to 4%, while the polymer vial took around 9% longer. At 200 mTorr, the API in the EasyLyo™ vials dried approximately 15% faster compared to the other vial types. The present study suggest that molded vials that have been modified in design to have better heat transfer properties can achieve drying times comparable to tubing vials.

  11. Effect of nettle (Urtica dioica extract on gentamicin induced nephrotoxicity in male rabbits

    Directory of Open Access Journals (Sweden)

    Nadia Abdulkarim Salih

    2015-09-01

    Conclusions: Therefore, it can be assumed that the nephroprotective effect shown by nettle in gentamicin-induced nephrotoxicity can reserve intracellular levels of biological pathways and supportively enhance excretion of toxic levels of gentamicin.

  12. Perioperative antimicrobial prophylaxis in neurosurgery: clinical trial of systemic flomoxef administration and saline containing gentamicin for irrigation.

    Science.gov (United States)

    Yamamoto, M; Jimbo, M; Ide, M; Tanaka, N; Umebara, Y; Hagiwara, S

    1996-06-01

    The efficacy of a new protocol consisting of a prophylactic antibiotic regimen of peri- and postoperative intravenous administration of flomoxef and irrigation of the operative field with saline containing gentamicin was assessed by comparing infection rates in two consecutive series of patients who underwent neurosurgical procedures. Group A received postoperative flomoxef administration, with saline containing no antibiotics for irrigation, from July 1988 to December 1989. Group B received the new protocol from January 1990 to December 1991. For further evaluation, this protocol was continued in most patients who underwent surgery from January 1992 through December 1993 (Group C). Only adult or adolescent patients who underwent clean neurosurgical procedures were included. The number of patients and procedures in each group were: 76 patients (97 procedures) in Group A, 103 (133) in Group B, and 107 (137) in Group C. There were no significant differences between Groups A and B in age, sex, clinical category, coexistent disease, clinical outcome, surgical procedures, general anesthesia, emergency operation, steroid administration, and the timing (season), duration, and frequency of surgery. Meningitis developed in three patients and subcutaneous infection in one in Group A. None of the patients in Group B experienced postoperative infection. This difference in infection rates (4.1% vs. 0%) was statistically significant (p = 0.0305). Furthermore, no postoperative infections developed in the Group C patients. The most appropriate interval for multiple dose administration was determined by analyzing intraoperative time-related changes in the serum flomoxef concentration during surgery in 21 recent patients. Serum flomoxef concentrations fell below therapeutic levels (3.0 micrograms/ml) by the 6th post-administration hour in 70% of patients. We conclude that this antibiotic regimen significantly reduces the postoperative infection rate following neurosurgical

  13. Comparative study of bacteremias caused by Enterococcus spp. with and without high-level resistance to gentamicin. The Grupo Andaluz para el estudio de las Enfermedades Infecciosas.

    Science.gov (United States)

    Caballero-Granado, F J; Cisneros, J M; Luque, R; Torres-Tortosa, M; Gamboa, F; Díez, F; Villanueva, J L; Pérez-Cano, R; Pasquau, J; Merino, D; Menchero, A; Mora, D; López-Ruz, M A; Vergara, A

    1998-02-01

    A prospective, multicenter study was carried out over a period of 10 months. All patients with clinically significant bacteremia caused by Enterococcus spp. were included. The epidemiological, microbiological, clinical, and prognostic features and the relationship of these features to the presence of high-level resistance to gentamicin (HLRG) were studied. Ninety-three patients with enterococcal bacteremia were included, and 31 of these cases were caused by HLRG (33%). The multivariate analysis selected chronic renal failure, intensive care unit stay, previous use of antimicrobial agents, and Enterococcus faecalis species as the independent risk factors that influenced the development of HLRG. The strains with HLRG showed lower levels of susceptibility to penicillin and ciprofloxacin. Clinical features (except for chronic renal failure) were similar in both groups of patients. HLRG did not influence the prognosis for patients with enterococcal bacteremia in terms of either the crude mortality rate (29% for patients with bacteremia caused by enterococci with HLRG and 28% for patients not infected with strains with HLRG) or the hospital stay after the acquisition of enterococcal bacteremia. Hemodynamic compromise, inappropriate antimicrobial therapy, and mechanical ventilation were revealed in the multivariate analysis to be the independent risk factors for mortality. Prolonged hospitalization was associated with the nosocomial acquisition of bacteremia and polymicrobial infections.

  14. Study of aac(6'Ie-aph(2″Ia Gene in Clinical Strain of Enterococci and Identification of High-Level Gentamicin Resistante Enterococci

    Directory of Open Access Journals (Sweden)

    N. Dadfarma

    2010-10-01

    Full Text Available Introduction & Objective: Enterococci have emerged as the leading nosocomial pathogens. In addition to natural resistance to many agents, enterococci have also developed plasmid- and transposon-mediated resistance to high concentrations of aminoglycosides. High-level gentamicin resistance (HLGR of enterococci results in the failure of drug synergism with an aminoglycoside plus cell-wall-active agents. HLGR (MIC=500μg/ml strains is usually due to the presence of the aac(6'Ie-aph(2″Ia gene . Materials & Methods: In the present experimental study 142 enterococci were isolated from the patients’ species. Identification was done by using standard methods and antimicrobial susceptibility test was performed by disc diffusion technique. MIC of Gentamicin was determined by a broth micro dilution method (NCCLS. PCR was performed to detect the aac(6'Ie-aph(2″Ia gene .Presence of the gene aac(6'-Ie-aph(2″-Ia was confirmed by digest with Sca1 enzyme. A PCR product was sequenced and BLAST analyzed at the NCBI database to be confirmed. Results: 62(43.7% out of the 142 isolates, were found to exhibit HLGR phenotype. MIC ranging from 512 to >1024 μg/ml in 55 HLGR isolates. All resistant isolates except one, were found to harbor the aac(6'Ie-aph(2″Ia gene. In our strain collection, 42% of E. faecalis and 44% of E. faecium were HLGR. In the HLGR isolates the prevalence of resistance to other antibiotics and Multi Drug Resistance (MDR was higher than non–HLGR.This prevalence in E.faecium was higher than E.faecalis. The sequence was compared with a published sequence and confirmed. Conclusion: Our results indicate that high prevalence of MDR and HLGR enterococcal colonization is an important problem in our medical centers.Spread of the aac(6'-Ie-aph(2″-Ia gene was responsible for HLGR among enterococci isolated from the patients in Tehran. (Sci J Hamadan Univ Med Sci 2010;17(3:25-32

  15. Gentamicin Exposure and Sensorineural Hearing Loss in Preterm Infants.

    Directory of Open Access Journals (Sweden)

    Aline Fuchs

    Full Text Available To evaluate the impact of gentamicin exposure on sensorineural hearing loss (SNHL in very low birth weight (VLBW infants.Exposure to gentamicin was determined in infants born between 1993 and 2010 at a gestational age < 32 weeks and/or with a birthweight < 1500 g, who presented with SNHL during the first 5 years of life. For each case, we selected two controls matched for gender, gestational age, birthweight, and year of birth.We identified 25 infants affected by SNHL, leading to an incidence of SNHL of 1.58% in our population of VLBW infants. The proportion of infants treated with gentamicin was 76% in the study group and 70% in controls (p = 0.78. The total cumulated dose of gentamicin administered did not differ between the study group (median 10.2 mg/kg, Q1-Q3 1.6-13.2 and the control group (median 7.9 mg/kg, Q1-Q3 0-12.8, p = 0.47. The median duration of gentamicin treatment was 3 days both in the study group and the control group (p = 0.58. Maximum predicted trough serum levels of gentamicin, cumulative area under the curve and gentamicin clearance were not different between cases and controls.The impact of gentamicin on SNHL can be minimized with treatments of short duration, monitoring of blood levels and dose adjustment.

  16. Safety of gentamicin bladder irrigations in complex urological cases.

    Science.gov (United States)

    Defoor, William; Ferguson, Denise; Mashni, Susan; Creelman, Lisa; Reeves, Deborah; Minevich, Eugene; Reddy, Pramod; Sheldon, Curtis

    2006-05-01

    Recurrent urinary tract infections are common in complex pediatric urological cases, particularly those requiring clean intermittent catheterization. At our institution gentamicin bladder irrigations have been used for antimicrobial prophylaxis and to treat symptomatic bacteriuria, particularly when the infection does not involve the upper urinary tract. The purpose of this study was to assess the safety of this therapy. A retrospective study was performed of all children treated with gentamicin bladder irrigations from 1999 to 2004. The dose was 14 mg gentamicin in 30 ml saline instilled via catheter once or twice daily. Serum creatinine and random gentamicin levels were obtained according to a protocol based on risk of gentamicin toxicity. Patient demographics, laboratory results and outcomes were abstracted from the medical records. A total of 80 patients (38 males and 42 females) were identified. Median patient age was 10 years and median duration of treatment was 90 days. No patient had detectable serum gentamicin levels greater than 0.4 mg/dl. Small increases in serum creatinine were seen in 3 patients, all of whom had chronic renal insufficiency. A total of 21 patients (26%) had breakthrough UTIs, of which 5 (24%) were gentamicin resistant. No adverse events were documented. Gentamicin bladder irrigations are a helpful adjunct in the management of complex pediatric urological cases involving recurrent symptomatic bacteriuria. We no longer require intensive laboratory monitoring of low risk patients at our institution.

  17. Optimising intraperitoneal gentamicin dosing in peritoneal dialysis patients with peritonitis (GIPD study

    Directory of Open Access Journals (Sweden)

    Lipman Jeffrey

    2009-12-01

    Full Text Available Abstract Background Antibiotics are preferentially delivered via the peritoneal route to treat peritonitis, a major complication of peritoneal dialysis (PD, so that maximal concentrations are delivered at the site of infection. However, drugs administered intraperitoneally can be absorbed into the systemic circulation. Drugs excreted by the kidneys accumulate in PD patients, increasing the risk of toxicity. The aim of this study is to examine a model of gentamicin pharmacokinetics and to develop an intraperitoneal drug dosing regime that maximises bacterial killing and minimises toxicity. Methods/Design This is an observational pharmacokinetic study of consecutive PD patients presenting to the Royal Brisbane and Women's Hospital with PD peritonitis and who meet the inclusion criteria. Participants will be allocated to either group 1, if anuric as defined by urine output less than 100 ml/day, or group 2: if non-anuric, as defined by urine output more than 100 ml/day. Recruitment will be limited to 15 participants in each group. Gentamicin dosing will be based on the present Royal Brisbane & Women's Hospital guidelines, which reflect the current International Society for Peritoneal Dialysis Peritonitis Treatment Recommendations. The primary endpoint is to describe the pharmacokinetics of gentamicin administered intraperitoneally in PD patients with peritonitis based on serial blood and dialysate drug levels. Discussion The study will develop improved dosing recommendations for intraperitoneally administered gentamicin in PD patients with peritonitis. This will guide clinicians and pharmacists in selecting the most appropriate dosing regime of intraperitoneal gentamicin to treat peritonitis. Trial Registration ACTRN12609000446268

  18. Hydrogel iontophoresis for gentamicin administration to the rabbit eye

    Science.gov (United States)

    Eljarrat-Binstock, Esther; Raiskup, Frederik; Frucht-Pery, Joseph; Domb, Abraham J.

    2005-04-01

    Iontophoresis (IONT) is a non-invasive technique in which a low electric current is used to enhance the penetration of charged molecules into tissue. This technique has been used in various fields of medicine, mostly in transdermal drug delivery. This study was aimed to evaluate the efficacy and the distribution profile of gentamicin using corneal IONT on infected and healthy rabbit eyes. Corneal iontophoresis of gentamicin sulfate was studied using drug-loaded disposable hydrogel probes mounted on a portable iontophoretic device, applying a low current for 60 seconds. This study confirmed that a triple iontophoretic treatment of gentamicin for only 60 seconds (0.5mA) significantly reduces the count of pseudomonas in the infected cornea to a non-infectious level. Peak gentamicin concentrations at the healthy corneas (363.1 +/- 127.3 μg/g) and at the aqueous humor (29.4 +/- 17.4 μg/ml) were reached immediately and two hours after a single iontophoretic treatment, respectively. The concentration versus time profile of gentamicin following iontophoresis revealed a gentamicin half life of 2.07 h in the anterior chamber, and a clearance of 1.73 μl/min from the anterior chamber to the posterior segments of the eye. This study indicates that a short iontophoretic treatment using gentamicin-loaded hydrogels has a potential clinical value in treating corneal infections, by increasing drug penetration to the eye and maintaining therapeutic levels for more than eight hours.

  19. Fosfomycin Addition to Poly(D,L-Lactide Coating Does Not Affect Prophylaxis Efficacy in Rat Implant-Related Infection Model, But That of Gentamicin Does.

    Directory of Open Access Journals (Sweden)

    Anil Gulcu

    Full Text Available Gentamicin is the preferred antimicrobial agent used in implant coating for the prevention of implant-related infections (IRI. However, the present heavy local and systemic administration of gentamicin can lead to increased resistance, which has made its future use uncertain, together with related preventive technologies. Fosfomycin is an alternative antimicrobial agent that lacks the cross-resistance presented by other classes of antibiotics. We evaluated the efficacy of prophylaxis of 10% fosfomycin-containing poly(D,L-lactide (PDL coated K-wires in a rat IRI model and compared it with uncoated (Control 1, PDL-coated (Control 2, and 10% gentamicin-containing PDL-coated groups with a single layer of coating. Stainless steel K-wires were implanted and methicillin-resistant Staphylococcus aureus (ATCC 43300 suspensions (103 CFU/10 μl were injected into a cavity in the left tibiae. Thereafter, K-wires were removed and cultured in tryptic soy broth and then 5% sheep blood agar mediums. Sliced sections were removed from the tibiae, stained with hematoxylin-eosin, and semi-quantitatively evaluated with X-rays. The addition of fosfomycin into PDL did not affect the X-ray and histopathological evaluation scores; however, the addition of gentamicin lowered them. The addition of gentamicin showed a protective effect after the 28th day of X-ray evaluations. PDL-only coating provided no protection, while adding fosfomycin to PDL offered a 20% level protection and adding gentamicin offered 80%. Furthermore, there were 103 CFU level growths in the gentamicin-added group, while the other groups had 105. Thus, the addition of fosfomycin to PDL does not affect the efficacy of prophylaxis, but the addition of gentamicin does. We therefore do not advise the use of fosfomycin as a single antimicrobial agent in coating for IRI prophylaxis.

  20. Gentamicin nephrotoxicity: Animal experimental correlate with human pharmacovigilance outcome

    Directory of Open Access Journals (Sweden)

    Olufunsho Awodele

    2015-04-01

    Full Text Available Background: National Agency for Food and Drugs Administration and Control (NAFDAC, which is responsible for pharmacovigilance activity in Nigeria, recently withdrew injection gentamicin 280 mg, used in the management of life-threatening and multidrug-resistant infections from circulation, due to reported toxicity. Thus, this study aimed to investigate the toxicity profile of the commonly used strengths (80 mg and 280 mg of gentamicin on kidney using animal models. Methods: Animals were divided into five groups of 16 rats each. For rats of groups 1 and 2, gentamicin (1.14 mg/kg each group was administered intramuscularly twice daily for 7 and 14 days, respectively, after which eight of them were sacrificed by cervical dislocation. Blood was collected via cardiac puncture and the kidneys were carefully removed and weighed immediately. The remaining eight animals were kept for reversibility study for another 7 and 14 days, respectively. For groups 3 and 4, gentamicin (4 mg/kg each group was administered as a single daily dose for 7 and 14 days, respectively, and eight animals from the groups were subjected to reversibility study for 7 and 14 days, respectively. Group 5, the control group animals, were given 10 ml/kg distilled water for 14 days. Histopathology of the kidneys, serum creatinine levels, and antioxidant enzyme activities were investigated. Results: Significant increase (p ≤ 0.001 in the level of creatinine of rats administered 4.0 mg/kg for 14 days was observed compared with all other groups. Significant (p ≤ 0.001 elevations in the lipid peroxidation in all gentamicin-administered animals and acute tubular necrosis in most of the gentamicin-administered animals were observed. Conclusion: Toxicity profile of gentamicin on the kidneys is dependent on both dose and duration of administration. The findings justify the decision made by NAFDAC to ban the use of high-dose inj. gentamicin 280 mg in Nigeria.

  1. Gentamicin release from commercially-available gentamicin-loaded PMMA bone cements in a prosthesis-related interfacial gap model and their antibacterial efficacy

    Directory of Open Access Journals (Sweden)

    van der Mei Henny C

    2010-11-01

    Full Text Available Abstract Background Around about 1970, a gentamicin-loaded poly (methylmethacrylate (PMMA bone cement brand (Refobacin Palacos R was introduced to control infection in joint arthroplasties. In 2005, this brand was replaced by two gentamicin-loaded follow-up brands, Refobacin Bone Cement R and Palacos R + G. In addition, another gentamicin-loaded cement brand, SmartSet GHV, was introduced in Europe in 2003. In the present study, we investigated differences in gentamicin release and the antibacterial efficacy of the eluent between these four cement brands. Methods 200 μm-wide gaps were made in samples of each cement and filled with buffer in order to measure the gentamicin release. Release kinetics were related to bone cement powder particle characteristics and wettabilities of the cement surfaces. Gaps were also inoculated with bacteria isolated from infected prostheses for 24 h and their survival determined. Gentamicin release and bacterial survival were statistically analysed using the Student's t-test. Results All three Palacos variants showed equal burst releases but each of the successor Palacos cements showed significantly higher sustained releases. SmartSet GHV showed a significantly higher burst release, while its sustained release was comparable with original Palacos. A gentamicin-sensitive bacterium did not survive in the high gentamicin concentrations in the interfacial gaps, while a gentamicin-resistant strain did, regardless of the type of cement used. Survival was independent of the level of burst release by the bone cement. Conclusions Although marketed as the original gentamicin-loaded Palacos cement, orthopaedic surgeons should be aware that the successor cements do not appear to have the same release characteristics as the original one. Overall, high gentamicin concentrations were reached inside our prosthesis-related interfacial gap model. These concentrations may be expected to effectively decontaminate the prosthesis

  2. Could edaravone prevent gentamicin ototoxicity? An experimental study.

    Science.gov (United States)

    Turan, M; Ciğer, E; Arslanoğlu, S; Börekci, H; Önal, K

    2017-02-01

    Clinical application of gentamicin may cause nephrotoxicity and ototoxicity. Our study is the first study to investigate the protective effects of edaravone against the gentamicin-induced ototoxicity. We investigated the protective effect of intraperitoneal (i.p.) edaravone application against gentamicin-induced ototoxicity in guinea pigs. Fourteen guinea pigs were divided into two equal groups consisting of a control group and a study group. One-hundred sixty milligrams per kilogram subcutaneous gentamicin and 0.3 mL i.p. saline were applied simultaneously once daily to seven guinea pigs in the control group (group 1). One-hundred sixty milligrams per kilogram gentamicin was applied subcutaneously and 3 mg/kg edaravone was applied intraperitoneally once daily for 7 days simultaneously to seven guinea pigs in the study group (group 2). Following the drug application, auditory brainstem response measurements were performed for the left ear on the 3rd and 7th days. Hearing threshold values of the group 1 and group 2 measured in the 3rd day of the study were detected as 57.14 ± 4.88 and 82.86 ± 7.56, respectively. This difference was statistically significant ( p edaravone-administered group 2 and that of group 1 without edaravone was found. These differences show that systemic edaravone administration could diminish ototoxic effects of gentamicin and the severity of the hearing loss.

  3. A simple high-dose gentamicin regimen showed no side effects among neonates

    DEFF Research Database (Denmark)

    Blaabjerg, Anne Sofie; Kofoed, Poul-Erik; Dalegaard, Mette Correll

    2017-01-01

    INTRODUCTION: Treatment of infections in neonates with gentamicin is a balance between optimising bactericidal effect and minimising adverse effects. Previously, at the Neonatal Intensive Care Unit (NICU) at Kolding Hospital, Denmark, neonates suspected of having infections were treated daily...... and 2012 and treated with gentamicin were included retrospectively in the study. Neonates with trough serum (S)-gentamicin level ≥ 2.0 mg/l before the third dose were reviewed in detail. RESULTS: In total, S-gentamicin level was measured in 253 treated neonates of whom 7% displayed elevated trough values....... Neonates elevated S...

  4. Scoring system to guide decision making for the use of gentamicin-impregnated collagen sponge to prevent deep sternal wound infection.

    Science.gov (United States)

    Benedetto, Umberto; Raja, Shahzad G

    2014-11-01

    The effectiveness of the routine retrosternal placement of a gentamicin-impregnated collagen sponge (GICS) implant before sternotomy closure is currently a matter of some controversy. We aimed to develop a scoring system to guide decision making for the use of GICS to prevent deep sternal wound infection. Fast backward elimination on predictors, including GICS, was performed using the Lawless and Singhal method. The scoring system was reported as a partial nomogram that can be used to manually obtain predicted individual risk of deep sternal wound infection from the regression model. Bootstrapping validation of the regression models was performed. The final populations consisted of 8750 adult patients undergoing cardiac surgery through full sternotomy during the study period. A total of 329 patients (3.8%) received GICS implant. The overall incidence of deep sternal wound infection was lower among patients who received GICS implant (0.6%) than patients who did not (2.01%) (P=.02). A nomogram to predict the individual risk for deep sternal wound infection was developed that included the use of GICS. Bootstrapping validation confirmed a good discriminative power of the models. The scoring system provides an impartial assessment of the decision-making process for clinicians to establish if GICS implant is effective in reducing the risk for deep sternal wound infection in individual patients undergoing cardiac surgery through full sternotomy. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. Comparative evaluation of topical Sodium fusidate cream in common pyodermas with topical gentamicin ointment and systemic antibiotics

    Directory of Open Access Journals (Sweden)

    Roy AK

    1996-01-01

    Full Text Available ABSTRACT: One hundred cases of common pyodermas consisting of four groups, namely impetigo, furunculosis and chronic folliculitis were taken. Each group containing twenty five cases were divided again into three subgroups. From each group, 15 were treated with 2 percent Sodium fusidate cream, 5 were with 0.1 percent Gentamycin sulphate cream and the rest 5 with systemic Erythromycin stearate. In the group of Impetigo, Bockhart′s Impetigo and Furunculosis, topical Sodium fusidate cream showed excellent result, better than Gentamycin topical and equal to that of systemic Erythromycin stearate.

  6. Effects of Gentamicin on Urinary Electrolyte Excretion in Admitted Neonate

    Directory of Open Access Journals (Sweden)

    B. Falakolaflaki

    2008-01-01

    Full Text Available Introduction & Objective: Gentamicin is an aminoglycoside antibiotic widely used during the neonatal period. It is associated with nephrotoxic effects in neonates, including glomerular impairment and renal tubular dysfunction. Electrolyte balance is very important, especially in the sick premature neonate receiving aminoglycosides. The purpose of this study was early diagnosis of gentamicin nephrotoxicity. Materials & Methods: This quasi-experimental study was performed on 23 neonates (11 full – term and 12 preterm with suspected sepsis who were admitted and treated with gentamicin. Blood and urine samples were collected before infusion and on the 3rd day of treatment. Serum and urine concentration of Na, K, creatinine (Cr and urine concentration of Ca were measured. Then fractional excretion of Na and K were estimated. Ca excretion was estimated as the UCa/UCr ratio. Then the collected data were analyzed using SPSS package.Results: In all neonates, increase in fractional excretion of Na and UCa/UCr, in the 3rd day of treatment were observed as compared to those of before infusion (P=0.01 and P=0.02 respectively. Serum creatinine levels decreased in all patients. Serum level of electrolytes during therapy was normal.Conclusion: The results of this study clearly demonstrate an effect of gentamicin infusion on renal sodium and calcium excretion. These results may be of clinical importance especially for sick preterm neonates receiving treatment with gentamicin. These babies are usually salt-losers and are also more susceptible to early onset hypocalcemia. Gentamicin can aggravate these complications.

  7. Correlation between apramycin and gentamicin use in pigs and an increasing reservoir of gentamicin-resistant Escherichia coli

    DEFF Research Database (Denmark)

    Jensen, Vibeke Frøkjær; Jakobsen, Lotte; Emborg, Hanne-Dorthe

    2006-01-01

    Objectives: Resistance towards the veterinary drug apramycin can be caused by the aac(3)-IV gene, which also confers resistance towards the important human antibiotic gentamicin. The objectives of this study were to investigate the temporal occurrence and the genetic background of apramycin...... and gentamicin resistance in Escherichia coli strains from pork, healthy pigs and diagnostic submissions from pigs and to investigate potential relationships to the use of apramycin and gentamicin at farm and national levels. Methods: Data on Danish E. coli isolates from healthy pigs (indicator bacteria......), diagnostic submissions from pigs (clinical isolates) and pork were obtained from the national surveillance of antimicrobial resistance and from routine diagnostic laboratories. Antimicrobial consumption data were obtained from the Danish Medicines Agency (1997-2000) and from the VetStat database (2001...

  8. Tauroursodeoxycholic acid attenuates gentamicin-induced cochlear hair cell death in vitro.

    Science.gov (United States)

    Jia, Zhanwei; He, Qiang; Shan, Chunguang; Li, Fengyi

    2018-09-15

    Gentamycin is one of the most clinically used aminoglycoside antibiotics which induce intrinsic apoptosis of hair cells. Tauroursodeoxycholic acid (TUDCA) is known as safe cell-protective agent in disorders associated with apoptosis. We aimed to investigate the protective effects of TUDCA against gentamicin-induced ototoxicity. House Ear Institute-Organ of Corti 1(HEI-OC1) cells and explanted cochlear tissue were treated with gentamicin and TUDCA, followed by serial analyses including cell viability assay, hair cell staining, qPCR, ELISA and western blotting to determine the cell damage by the parameters relevant to cell apoptosis and endoplasmic reticulum stress. TUDCA significantly attenuated gentamicin-induced cell damage in cultured HEI-OC1 cells and explanted cochlear hair cells. TUDCA alleviated gentamicin-induced cell apoptosis, supported by the decreased Bax/Bcl2 ratio compared with that of gentamicin treated alone. TUDCA decreased gentamicin-induced nitric oxide production and protein nitration in both models. In addition, TUDCA suppressed gentamicin-induced endoplasmic reticulum stress as reflected by inversing the expression levels of Binding immunoglobulin protein (Bip), CCAAT/-enhancer-binding protein homologous protein (CHOP) and Caspase 3. TUDCA attenuated gentamicin-induced hair cell death by inhibiting protein nitration activation and ER stress, providing new insights into the new potential therapies for sensorineural deafness. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Compound list: gentamicin [Open TG-GATEs

    Lifescience Database Archive (English)

    Full Text Available gentamicin GMC 00147 ftp://ftp.biosciencedbc.jp/archive/open-tggates/LATEST/Rat/in_vitro/gentam...icin.Rat.in_vitro.Liver.zip ftp://ftp.biosciencedbc.jp/archive/open-tggates/LATEST/Rat/in_vivo/Liver/Single/gentam...at/in_vivo/Liver/Repeat/gentamicin.Rat.in_vivo.Liver.Repeat.zip ftp://ftp.bioscie...ncedbc.jp/archive/open-tggates/LATEST/Rat/in_vivo/Kidney/Single/gentamicin.Rat.in_vivo.Kidney.Single.zip ftp...://ftp.biosciencedbc.jp/archive/open-tggates/LATEST/Rat/in_vivo/Kidney/Repeat/gentamicin.Rat.in_vivo.Kidney.Repeat.zip ...

  10. Concepts for increasing gentamicin release from handmade bone cement beads

    NARCIS (Netherlands)

    Rasyid, Hermawan N; van der Mei, Henny C; Frijlink, Henderik W; Soegijoko, Soegijardjo; Van Horn, Jim R; Busscher, Hendrik; Neut, Daniëlle

    2009-01-01

    BACKGROUND AND PURPOSE: Commercial gentamicin-loaded bone cement beads (Septopal) constitute an effective delivery system for local antibiotic therapy. These beads are not available in all parts of the world, and are too expensive for frequent use in others. Thus, orthopedic surgeons worldwide make

  11. Immunological methods for gentamicin determination

    International Nuclear Information System (INIS)

    Krugers Dagneauz, P.G.L.C.; Olthuis, F.M.F.G.

    1979-01-01

    For immunoassay, an antibody against the substance to the determined, the pure substance itself, and a labelled form or derivative of the substance are required. The principles and problems of the preparation of antibodies are discussed, some methods for the preparation of derivatives labelled with radioactive tracers or enzymes are reviewed, and homologous enzyme-immunological determination of gentamicin is discussed in detail. A comparison is mae of three radio-immunological determination methods, and the most suitable radio-immunological method is compared with two microbiological techniques. The results are found to be comparable. (Auth.)

  12. A prospective study of gentamicin ototoxicity

    DEFF Research Database (Denmark)

    Winkel, O; Hansen, M M; Kaaber-Bühler, Søren

    2010-01-01

    of gentamicin did not rule out the possiblity of ototoxicity. These results urge the continuing of prospective studies and indicate that gentamicin should be used only as a link in the primary treatment of severe infection or in cases in which other, less toxic agents have failed....

  13. A prospective study of gentamicin ototoxicity

    DEFF Research Database (Denmark)

    Winkel, O; Hansen, M M; Kaaber-Bühler, Søren

    1978-01-01

    of gentamicin did not rule out the possiblity of ototoxicity. These results urge the continuing of prospective studies and indicate that gentamicin should be used only as a link in the primary treatment of severe infection or in cases in which other, less toxic agents have failed....

  14. Residual gentamicin-release from antibiotic-loaded polymethylmethacrylate beads after 5 years of implantation

    NARCIS (Netherlands)

    Neut, D; van de Belt, H; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    In infected joint arthroplasty, high local levels of antibiotics are achieved through temporary implantation of non-biodegradable gentamicin-loaded polymethylmethacrylate beads. Despite their antibiotic release, these beads act as a biomaterial surface to which bacteria preferentially adhere, grow

  15. Pharmacokinetic modeling of gentamicin in treatment of infective endocarditis : Model development and validation of existing models

    NARCIS (Netherlands)

    Gomes, Anna; van der Wijk, Lars; Proost, Johannes H; Sinha, Bhanu; Touw, Daan J

    2017-01-01

    Gentamicin shows large variations in half-life and volume of distribution (Vd) within and between individuals. Thus, monitoring and accurately predicting serum levels are required to optimize effectiveness and minimize toxicity. Currently, two population pharmacokinetic models are applied for

  16. Agmatine improves renal function in gentamicin-induced nephrotoxicity in rats.

    Science.gov (United States)

    El-Kashef, Dalia H; El-Kenawi, Asmaa E; Abdel Rahim, Mona; Suddek, Ghada M; Salem, Hatem A

    2016-03-01

    The present study was designed to explore the possible protective effects of agmatine, a known nitric oxide (NO) synthase inhibitor, against gentamicin-induced nephrotoxicity in rats. For this purpose, we quantitatively evaluated gentamicin-induced renal structural and functional alterations using histopathological and biochemical approaches. Furthermore, the effect of agmatine on gentamicin-induced hypersensitivity of urinary bladder rings to acetylcholine (ACh) was evaluated. Twenty-four male Wistar albino rats were randomly divided into 3 groups, namely control, gentamicin (100 mg/kg, i.p.), and gentamicin plus agmatine (40 mg/kg, orally). At the end of the study, all rats were sacrificed and then blood and urine samples and kidneys were taken. Administration of agmatine significantly decreased kidney/body mass ratio, serum creatinine, lactate dehydrogenase (LDH), renal malondialdehyde (MDA), myeloperoxidase (MPO), NO, and tumor necrosis factor-alpha (TNF-α) while it significantly increased creatinine clearance and renal superoxide dismutase (SOD) activity when compared with the gentamicin-treated group. Additionally, agmatine ameliorated tissue morphology as evidenced by histological evaluation and reduced the responses of isolated bladder rings to ACh. Our study indicates that agmatine administration with gentamicin attenuates oxidative-stress associated renal injury by reducing oxygen free radicals and lipid peroxidation, restoring NO level and inhibiting inflammatory mediators such as TNF-α.

  17. System level ESD protection

    CERN Document Server

    Vashchenko, Vladislav

    2014-01-01

    This book addresses key aspects of analog integrated circuits and systems design related to system level electrostatic discharge (ESD) protection.  It is an invaluable reference for anyone developing systems-on-chip (SoC) and systems-on-package (SoP), integrated with system-level ESD protection. The book focuses on both the design of semiconductor integrated circuit (IC) components with embedded, on-chip system level protection and IC-system co-design. The readers will be enabled to bring the system level ESD protection solutions to the level of integrated circuits, thereby reducing or completely eliminating the need for additional, discrete components on the printed circuit board (PCB) and meeting system-level ESD requirements. The authors take a systematic approach, based on IC-system ESD protection co-design. A detailed description of the available IC-level ESD testing methods is provided, together with a discussion of the correlation between IC-level and system-level ESD testing methods. The IC-level ESD...

  18. Is Penicillin plus Gentamicin Synergistic against Clinical Group B Streptococcus isolates?: A in-vitro Study.

    Directory of Open Access Journals (Sweden)

    Corinne Ruppen

    2016-10-01

    Full Text Available Group B Streptococcus (GBS is increasingly causing invasive infections in nonpregnant adults. Elderly patients and those with comorbidities are at increased risk. On the basis of previous studies focusing on neonatal infections, penicillin plus gentamicin is recommended for infective endocarditis (IE and periprosthetic joint infections (PJI in adults. The purpose of this study was to investigate whether a synergism with penicillin and gentamicin is present in GBS isolates that caused IE and PJI. We used 5 GBS isolates, two clinical strains and three control strains, including one displaying high-level gentamicin resistance (HLGR. The results from the checkerboard and time-kill assays (TKAs were compared. For TKAs, antibiotic concentrations for penicillin were 0.048 and 0.2 mg/L, and for gentamicin 4 mg/L or 12.5 mg/L. In the checkerboard assay, the median fractional inhibitory concentration indices (FICIs of all isolates indicated indifference. TKAs for all isolates failed to demonstrate synergism with penicillin 0.048 or 0.2 mg/L, irrespective of gentamicin concentrations used. Rapid killing was seen with penicillin 0.048 mg/L plus either 4 mg/L or 12.5 mg/L gentamicin, from 2 h up to 8 h hours after antibiotic exposure. TKAs with penicillin 0.2 mg/L decreased the starting inoculum below the limit of quantification within 4 h to 6 h, irrespective of the addition of gentamicin. Fast killing was seen with penicillin 0.2 mg/L plus 12.5 mg/L gentamicin within the first 2 h. Our in vitro results indicate that the addition of gentamicin to penicillin contributes to faster killing at low penicillin concentrations, but only within the first few hours. Twenty-four hours after antibiotic exposure, PEN alone was bactericidal and synergism was not seen.

  19. Acquired Bartter syndrome following gentamicin therapy

    Directory of Open Access Journals (Sweden)

    J Singh

    2016-01-01

    Full Text Available Aminoglycoside nephrotoxicity may manifest as nonoliguric renal failure or tubular dysfunction, such as Fanconi-like syndrome, Bartter-like syndrome (BS, or distal renal tubular acidosis. We report a case who developed severe renal tubular dysfunction on the the 7 th day of gentamicin therapy, resulting in metabolic alkalosis, refractory hypokalemia, hypocalcemia, hypomagnesemia, and polyuria. The patient was diagnosed as a case of transient BS associated with gentamicin exposure. The patient recovered with conservative management.

  20. Acquired Bartter syndrome following gentamicin therapy.

    Science.gov (United States)

    Singh, J; Patel, M L; Gupta, K K; Pandey, S; Dinkar, A

    2016-01-01

    Aminoglycoside nephrotoxicity may manifest as nonoliguric renal failure or tubular dysfunction, such as Fanconi-like syndrome, Bartter-like syndrome (BS), or distal renal tubular acidosis. We report a case who developed severe renal tubular dysfunction on the the 7 th day of gentamicin therapy, resulting in metabolic alkalosis, refractory hypokalemia, hypocalcemia, hypomagnesemia, and polyuria. The patient was diagnosed as a case of transient BS associated with gentamicin exposure. The patient recovered with conservative management.

  1. K88 Fimbrial Adhesin Targeting of Microspheres Containing Gentamicin Made with Albumin Glycated with Lactose

    Directory of Open Access Journals (Sweden)

    Andre-i Sarabia-Sainz

    2015-09-01

    Full Text Available The formulation and characterization of gentamicin-loaded microspheres as a delivery system targeting enterotoxigenic Escherichia coli K88 (E. coli K88 was investigated. Glycated albumin with lactose (BSA-glucose-β (4-1 galactose was used as the microsphere matrix (MS-Lac and gentamicin included as the transported antibiotic. The proposed target strategy was that exposed galactoses of MS-Lac could be specifically recognized by E. coli K88 adhesins, and the delivery of gentamicin would inhibit bacterial growth. Lactosylated microspheres (MS-Lac1, MS-Lac2 and MS-Lac3 were obtained using a water-in-oil emulsion, containing gentamicin, followed by crosslinking with different concentrations of glutaraldehyde. Electron microscopy displayed spherical particles with a mean size of 10–17 µm. In vitro release of gentamicin from MS-Lac was best fitted to a first order model, and the antibacterial activity of encapsulated and free gentamicin was comparable. MS-Lac treatments were recognized by plant galactose-specific lectins from Ricinus communis and Sophora japonica and by E. coli K88 adhesins. Results indicate MS-Lac1, produced with 4.2 mg/mL of crosslinker, as the best treatment and that lactosylated microsphere are promising platforms to obtain an active, targeted system against E. coli K88 infections.

  2. Protective Effect of Bauhinia purpurea on Gentamicin-induced Nephrotoxicity in Rats

    Science.gov (United States)

    Lakshmi, B. V. S.; Neelima, N.; Kasthuri, N.; Umarani, V.; Sudhakar, M.

    2009-01-01

    The present study was undertaken to evaluate the ethanol extract of leaves of Bauhinia purpurea and unripe pods of Bauhinia purpurea for its protective effects on gentamicin-induced nephrotoxicity in rats. Nephrotoxicity was induced in Wistar rats by intraperitoneal administration of gentamicin 100 mg/kg/d for eight days. Effect of concurrent administration of ethanol extract of leaves of Bauhinia purpurea and unripe pods of Bauhinia purpurea at a dose of 300 mg/kg/d given by oral route was determined using serum creatinine, serum uric acid, blood urea nitrogen and serum urea as indicators of kidney damage. The study groups contained six rats in each group. It was observed that the ethanol extract of leaves of Bauhinia purpurea and unripe pods of Bauhinia purpurea significantly protect rat kidneys from gentamicin-induced histopathological changes. Gentamicin-induced glomerular congestion, blood vessel congestion, epithelial desquamation, accumulation of inflammatory cells and necrosis of the kidney cells were found to be reduced in the groups receiving the leaf and unripe pods extract of Bauhinia purpurea along with gentamicin. The extracts also normalized the gentamicin-induced increase in serum creatinine, serum uric acid and blood urea nitrogen levels. This is also evidenced by the histopathological studies. PMID:20502576

  3. PEP liquid level system

    International Nuclear Information System (INIS)

    Lauritzen, T.; Sah, R.C.

    1981-03-01

    A liquid level system has been installed in the accelerator housing of the PEP storage ring. This instrument spans the entire 2.2 km circumference of the PEP project, and over one hundred readouts provide reference elevations which are used for the accurate alignment of accelerator components. The liquid level has proven to be extremely precise (+-0.10 mm) and quick to use, and it has contributed to the accurate alignment of PEP before beam turn-on. Since the liquid level readouts are rigidly attached to the accelerator housing, the liquid level has been a convenient means to monitor the settling of the accelerator housing

  4. Effect of Helichrysum plicatum DC. subsp. plicatum ethanol extract on gentamicin-induced nephrotoxicity in rats.

    Science.gov (United States)

    Apaydin Yildirim, Betul; Kordali, Saban; Terim Kapakin, Kubra Asena; Yildirim, Fatih; Aktas Senocak, Esra; Altun, Serdar

    2017-06-01

    The aim of this study was to evaluate the possible therapeutic or protective effects of Helichrysum plicatum DC. subsp. plicatum ethanol extract (HPE) against gentamicin-induced nephrotoxicity. Thirty-six Sprague Dawley male rats weighing between 200 and 250 g were used as live material. They were formed into six groups containing 6 rats each and were allowed to adapt to laboratory conditions for 7 d. Group I: control, 5% DMSO intraperitoneal (i.p.); Group II: HPE 100 mg/(kg·d) i.p.; Group III: HPE 200 mg/(kg·d) i.p.; Group IV: gentamicin as 80 mg/(kg·d) i.p.; Group V: gentamicin as 80 mg/(kg·d) i.p.+HPE 100 mg/(kg·d) i.p.; and Group VI: gentamicin as 80 mg/(kg·d) i.p.+HPE 200 mg/(kg·d) i.p. for 8 d. Following treatment, serum, liver, and kidney tissues were used to assess blood urea nitrogen (BUN), creatinine, enzymatic and non-enzymatic antioxidants, and lipid peroxidation. Gentamicin significantly increased serum BUN, creatinin, and liver and kidney levels of malondialdehyde (MDA). It also decreased the activity of catalase (CAT), glutathione peroxidase (GPx), and superoxide dismutase (SOD). Treatment with the HPE 100 mg/kg reversed gentamicin-induced alterations as evidenced by decreased serum BUN and creatinin, liver and kidney oxidant marker, and tubular necrosis as well as by an increase in antioxidant enzymes. It was found that HPE 200 mg/kg significantly increased liver and kidney tissue MDA levels in nephrotoxicity in rats. As a result, these findings support the proposition that HPE in 100 mg/kg dose demonstrates in the kidney and liver as free radicals and scavenger to prevent the toxic effects of gentamicin in both the biochemical and histopathology parameters.

  5. Liquid Level Sensing System

    Science.gov (United States)

    Korman, Valentin (Inventor); Wiley, John T. (Inventor); Duffell, Amanda G. (Inventor)

    2014-01-01

    A liquid level sensing system includes waveguides disposed in a liquid and distributed along a path with a gap between adjacent waveguides. A source introduces electromagnetic energy into the waveguides at a first end of the path. A portion of the electromagnetic energy exits the waveguides at a second end of the path. A detector measures the portion of the electromagnetic energy exiting the second end of the path.

  6. Gentamicin-Loaded Thermosetting Hydrogel and Moldable Composite Scaffold: Formulation Study and Biologic Evaluation.

    Science.gov (United States)

    Dorati, Rossella; De Trizio, Antonella; Genta, Ida; Merelli, Alessia; Modena, Tiziana; Conti, Bice

    2017-06-01

    The aim was to design biodegradable drug delivery systems for gentamicin local delivery, meanwhile acting as scaffold for bone regeneration. Gentamicin-loaded thermosetting composite hydrogels were prepared combining chitosan with bovine bone substitutes (Orthoss® granules), beta-glycerophosphate as cross-linker, and lyophilized to obtain moldable composite scaffolds (moldable composite scaffold loaded with gentamicin [mCSG]). Diverse techniques for gentamicin loading into mCS were investigated by drug incorporation during hydrogel preparation or drug absorption on preformed mCS. Rheologic hydrogel characterization was performed. mCSGs were characterized for porosity, stability (water retention, water uptake), gentamicin release, cell seeding and proliferation, and antimicrobial effect on Escherichia coli ATCC 10356. Results show suitable gentamicin loadings were 4 mg in 1 mL thermosetting composite hydrogel starting solution, irreversible hydrogel thermosetting behavior, and cosolute effect of gentamicin on sol-gel transition. Positive results in terms of porosity (80%-86%), scaffold water uptake, and retention capability were obtained. Antibiotic in vitro release was completed in 4 h. Good cell seeding results were observed for mCSG1-5; mCSG3 and mCSG5 resulted the best as cell proliferation results. mCSG exerted bactericidal effect for 24 h, with superimposition of chitosan bacteriostatic effect in the first 4 h. The results lead to consider the drug delivery for reducing infection risk during bone open surgeries. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Gentamicin serum concentrations in patients with gentamicin-PMMA beads for infected hip joints : A prospective observational cohort study

    NARCIS (Netherlands)

    De Klaver, Paul A.G.; Hendriks, Johannes G.E.; Van Onzenoort, Hein A.W.; Schreurs, Berend W.; Touw, Daan J.; Derijks, Luc J.J.

    Background: Gentamicin-polymethylmethacrylate (PMMA) beads release gentamicin gradually, and high concentrations develop only locally. It is unclear how frequent and in which patients gentamicin serum concentrations are measurable and possibly lead to toxicity. The aim of this study was to

  8. Evaluation of nephroprotective activity of Musa paradisiaca L. in gentamicin-induced nephrotoxicity.

    Science.gov (United States)

    Abbas, Khizar; Rizwani, Ghazala H; Zahid, Hina; Qadir, M Imran

    2017-05-01

    The objective of the study was to investigate the nephroprotective activity of methanolic extract of different morphological parts (bract, flower, trachea and tracheal fluid) of Musa paradisiaca L. (Family: Musaceae) against gentamicin-induced nephrotoxicity in mice. Gentamicin produced significant changes in biochemical (increased levels of blood urea nitrogen level, blood urea, and serum creatinine), and histological parameters in mice. Treatment with methanolic extract of bract (100 and 250mg/kg, b.w) and flowering stalk (trachea) (250 and 500mg/kg, b.w) significantly prevented biochemical and histological changes produced by gentamicin toxicity. The extracts of M. paradisiaca (bract and flowering stalk) could contribute a lead to discovery of a new drug for the treatment of drug-induced nephrotoxicity.

  9. Intestinal transport of gentamicin with a novel, glycosteroid drug transport agent

    Science.gov (United States)

    Axelrod, H. R.; Kim, J. S.; Longley, C. B.; Lipka, E.; Amidon, G. L.; Kakarla, R.; Hui, Y. W.; Weber, S. J.; Choe, S.; Sofia, M. J.

    1998-01-01

    PURPOSE: The objective was to investigate the ability of a glycosteroid (TC002) to increase the oral bioavailability of gentamicin. METHODS: Admixtures of gentamicin and TC002 were administered to the rat ileum by injection and to dogs by ileal or jejunal externalized ports, or PO. Bioavailability of gentamicin was determined by HPLC. 3H-TC002 was injected via externalized cannulas into rat ileum or jejunum, or PO and its distribution and elimination was determined. The metabolism of TC002 in rats was evaluated by solid phase extraction and HPLC analysis of plasma, urine and feces following oral or intestinal administration. RESULTS: The bioavailability of gentamicin was substantially increased in the presence of TC002 in both rats and dogs. The level of absorption was dependent on the concentration of TC002 and site of administration. Greatest absorption occurred following ileal orjejunal administration. TC002 was significantly more efficacious than sodium taurocholate, but similar in cytotoxicity. TC002 remained primarily in the GI tract following oral or intestinal administration and cleared rapidly from the body. It was only partly metabolized in the GI tract, but was rapidly and completely converted to its metabolite in plasma and urine. CONCLUSIONS: TC002 shows promise as a new drug transport agent for promoting intestinal absorption of polar molecules such as gentamicin.

  10. Intramammary treatment with gentamicin in lactating cows with clinical and subclinical mastitis

    Directory of Open Access Journals (Sweden)

    Thamires Martins

    2016-04-01

    Full Text Available Abstract The study evaluated the microbiological profile of milk samples collected before and after mastitis treatment with gentamicin and investigated biofilms production and antimicrobial susceptibility of Staphylococcus spp. isolated. The presence of gentamicin residues in milk after the recommended withdrawal period was also evaluated. Antimicrobial residues were analyzed by Delvotest® SP NT over a period of 12 days beginning after 24 hours the last gentamicin application. Some of Staphylococcus spp. isolates were biofilm producers (19.05%. Staphylococcus spp. showed high levels of resistance to neomycin (16.95%, penicillin G (10.17%, and ampicillin (10.17%. Multidrug resistance to all antibiotics tested was observed in 1.69% of the Staphylococcus spp. isolates. Among 1440 mammary quarter milk samples 24.95% presented gentamicin residues after the withdrawal period. Gentamicin residues were also detected in 3.8% of samples from calibrated glass recorder jar (n=383 4.1 days after treatment. The indiscriminate use of antibiotics may lead to the emergence of multidrug-resistant strains as well as increasing the risk of presence of residues of these drugs in milk. These problems affect the milk quality and may become a public health problem.

  11. Radioimmunoassay, acetylating radio-enzymatic assay, and microbioassay of gentamicin: a comparative study

    International Nuclear Information System (INIS)

    Stevens, P.; Young, L.S.; Hewitt, W.L.

    1975-01-01

    Gentamicin is an aminoglycoside antibiotic widely used to treat gram-negative bacillary infections. Because it has a low therapeutic index, monitoring of serum levels may help to insure adequacy of dosage and avoid toxicity. Microbiological assays are relatively slow and can be complicated by the presence of other antimicrobials. Radioimmunoassay (RIA) and acetylating radio-enzymatic assay (ARA) are new methods for gentamicin assay which offer the following advantages: rapidity (less than 3 hours); no interference by other antibiotics; RIA is extremely sensitive and ARA is versatile (being useful in the measurement of other aminoglycosides). Correlation coefficients determined by linear regression analysis of assays on 36 patient samples performed in duplicate on 2 different days demonstrated no significant difference in measurement of gentamicin by each of the methods. Factors such as numbers of specimens, cost, and time involved will affect the decision of the method to be applied in individual laboratories. (U.S.)

  12. Sublethal Triclosan Exposure Decreases Susceptibility to Gentamicin and Other Aminoglycosides in Listeria monocytogenes

    DEFF Research Database (Denmark)

    Christensen, Ellen Gerd; Gram, Lone; Kastbjerg, Vicky Gaedt

    2011-01-01

    (containing quaternary ammonium compound) in four consecutive cultures did not alter the frequency of antibiotic-tolerant isolates, as determined by plating on 2x the MIC for a range of antibiotics. Exposure of eight strains of L. monocytogenes to 1 and 4 µg/ml triclosan did not alter triclosan sensitivity...... resistance remained at a high level also after five subcultures without triclosan or gentamicin. Aminoglycoside resistance can be caused by mutations in the target site, the 16S rRNA gene. However, such mutations were not detected in the N53-1-resistant isolates. A combination of gentamicin and ampicillin...

  13. Round window administration of gentamicin: a new method for the study of ototoxicity of cochlear hair cells.

    Science.gov (United States)

    Husmann, K R; Morgan, A S; Girod, D A; Durham, D

    1998-11-01

    Damage to inner ear sensory hair cells after systemic administration of ototoxic drugs has been documented in humans and animals. Birds have the ability to regenerate new hair cells to replace those damaged by drugs or noise. Unfortunately, the systemic administration of gentamicin damages both ears in a variable fashion with potentially confounding systemic drug effects. We developed a method of direct application of gentamicin to one cochlea of hatchling chickens, allowing the other ear to serve as a within-animal control. We tested variables including the vehicle for application, location of application, dosage, and duration of gentamicin exposure. After 5 or 28 days survival, the percent length damage to the cochlea and regeneration of hair cells was evaluated using scanning electron microscopy. Controls consisted of the opposite unexposed cochlea and additional animals which received saline instead of gentamicin. Excellent damage was achieved using gentamicin-soaked Gelfoam pledgets applied to the round window membrane. The percent length damage could be varied from 15 to 100% by changing the dosage of gentamicin, with exposures as short as 30 min. No damage was observed in control animals. Regeneration of hair cells was observed in both the base and apex by 28 days survival.

  14. Measurement of plasma gentamicin concentrations postchemical ciliary body ablation in dogs with chronic glaucoma.

    Science.gov (United States)

    Rankin, Amy J; Lanuza, Rick; KuKanich, Butch; Crumley, William C; Pucket, Jonathan D; Allbaugh, Rachel A; Meekins, Jessica M

    2016-01-01

    To investigate the absorption of gentamicin into the plasma after an intravitreal injection in dogs and to report the success rate of this procedure in lowering the intraocular pressure. Twenty-four client-owned dogs with chronic, end-stage glaucoma. Dogs received a unilateral (22) or bilateral (2) intravitreal injection of 25-40 mg of gentamicin (mean ± SD dose 2.57 ± 1.65 mg/kg and range 0.61-7.50 mg/kg) and 1 mg of dexamethasone per eye. Blood samples were collected at various time points following the intravitreal injection. Plasma concentrations of gentamicin were determined by liquid chromatography and mass spectrometry. The total plasma concentration of gentamicin ranged from 0.21 to 9.71 μg/mL (mean ± SD 2.15 ± 2.03). The mean gentamicin CMAX was 2.29 μg/mL at 2.54 h with a terminal half-life of 9.8 h. The success rate of the chemical ablation procedure was 86.4% (19/22 eyes) in dogs that had at least 1 month of follow-up. Intravitreal injection of gentamicin in eyes with chronic glaucoma resulted in detectable plasma levels in dogs and was successful in lowering the intraocular pressure in 86.4% of the eyes after the first procedure. © 2015 American College of Veterinary Ophthalmologists.

  15. Gentamicin Nephrotoxicity in Subclinical Renal Disease.

    Science.gov (United States)

    Frazier, Donita L.

    The purpose of the present study was to examine the pharmacokinetic disposition of gentamicin and to define the mechanisms which predispose to nephrotoxicity in subclinical renal disease. Subtotally nephrectomized beagle dogs were used as a model for human beings with compromised renal function secondary to a reduced number of functional nephrons. Using ultrastructural morphometry, light microscopy and clinical chemistry data, the model was defined and the nephrotoxic responses of intact dogs administered recommended doses of drug were compared to the response of subtotally nephrectomized dogs administered reduced doses based on each animal's clearance of drug. Lysosomal and mitochondrial morphometric changes suggested mechanisms for increased sensitivity. To determine if increased sensitivity in this model was dependent on altered serum concentrations, variable rate infusions based on individual pharmacokinetic disposition of drug were administered using computer-driven infusion pumps. Identical serum concentration-time profiles were achieved in normal dogs and subtotally nephrectomized dogs, however, toxicity was significantly greater in nephrectomized dogs. The difference in the nephrotoxic response was characterized by administering supratherapeutic doses of drug to dogs. Nephrectomized dogs given a recommended dose of gentamicin became oliguric during the second week of treatment and increasingly uremic after withdrawal of drug. In contrast, intact dogs administered 2 times the recommended dose of gentamicin become only slightly polyuric during week 4 of treatment. The need to individualize dosage regimens based on drug clearance and not serum creatinine nor creatinine clearance alone was substantiated by describing the pharmacokinetic disposition of gentamicin in spontaneously occurring disease states. Four individualized dosage regimens with differing predicted efficacy were then administered to nephrectomized dogs to determine their relative nephrotoxic

  16. Effect of pulsed ultrasound in combination with gentamicin on bacterial killing of biofilms on bone cements in vivo

    Science.gov (United States)

    Ensing, G.T.; Roeder, B.L.; Nelson, J.L.; van Horn, J.R.; van der Mei, H.C.; Busscher, H.J.; Pitt, W.G.

    2008-01-01

    Aim The aim of this study is to investigate whether pulsed ultrasound in combination with gentamicin yields increased killing of bacterial biofilms on bone cements in vivo. Methods and Results Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with E. coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement disks loaded with gentamicin were used, and in one group unloaded bone cement disks in combination with systemically administered gentamicin were used. Pulsed ultrasound with a mean acoustic intensity of 167 mW cm−2 and a maximum acoustic intensity of 500 mW cm−2 was applied from 24 h till 72 h post surgery on one of the two implanted disks. After euthanization, the bacteria removed from the disk were quantified. Application of ultrasound, combined with gentamicin, reduced the biofilm in all three groups varying between 58 to 69% compared to the negative control. Ultrasound proved to be safe with respect to creating skin lesions. Conclusions Ultrasound resulted in an tendency of improved efficacy of gentamicin, either applied locally or systemically. Significance and impact of Study This study implies that ultrasound could improve the prevention of infection, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice. PMID:16108785

  17. Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo.

    Science.gov (United States)

    Ensing, G T; Roeder, B L; Nelson, J L; van Horn, J R; van der Mei, H C; Busscher, H J; Pitt, W G

    2005-01-01

    The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with an Escherichia coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement discs loaded with gentamicin, freshly prepared and aged were used, and in one group unloaded bone cement discs in combination with systemically administered gentamicin. Pulsed ultrasound with a frequency of 28.48 kHz and a maximum acoustic intensity of 500 mW cm(-2) was applied continuously from 24 h till 72 h postsurgery on one of the two implanted discs. After euthanization and removal of the bacteria from the discs, the number of viable bacteria were quantified and skin samples were analysed for histopathological examination. Application of ultrasound, combined with gentamicin, reduced the viability of the biofilms in all three groups varying between 58 and 69% compared with the negative control. Histopathological examinations showed no skin lesions. Ultrasound resulted in a tendency of improved efficacy of gentamicin, either applied locally or systemically. Usage of ultrasound in this model proved to be safe. This study implies that ultrasound could improve the prevention of infection immediately after surgery, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice.

  18. Protective role of ginseng against gentamicin induced changes in kidney of albino mice

    International Nuclear Information System (INIS)

    Hafeez, M.; Saeed, F.

    2011-01-01

    Background: Use of gentamicin is now limited due to its toxic effects, mainly on kidney and vestibular system. Herbal products including ginseng has been reported to possess protective effects against drugs induced nephrotoxicity in experimental animals. The current investigation was designed to evaluate the effects of ginseng on gentamicin induced nephrotoxicity. Methods: Eighteen male albino mice of 6-8 weeks age, were divided into 3 groups. Group-A served as control and was given normal mouse diet; Group-B was given 80 mg/Kg/day of gentamicin intraperitoneally dissolved in 1 ml of distilled water for fifteen days. Group-C was given 80 mg/Kg/day of gentamicin intraperitoneally dissolved in 1 ml of distilled water along with 100 mg/Kg/day of ginseng orally dissolved in 1 ml of distilled water, also for fifteen days. At the end of the experiment, blood was drawn from each animal by cardiac puncture for renal function tests. Each animal was then sacrificed and kidneys removed for routine histological studies. Results: In group B, weight of the animals and kidneys decreased and there was significant increase in mean serum urea, creatinine and intraluminal diameter (p<0.001) of proximal convoluted tubules as compared to the controls (group-A). Moderate to severe necrotic and degenerative changes in proximal convoluted tubules were seen in this group. When the Ginseng and gentamicin were given together (group-C), a statistically significant improvement in the mean body and kidney weight along with improvement in renal function tests and tubular diameter were seen (p<0.001). Conclusion: It appears that Ginseng has some protective role against gentamicin induced nephrotoxicity. (author)

  19. Punica granatum improves renal function in gentamicin-induced nephropathy in rats via attenuation of oxidative stress.

    Science.gov (United States)

    Mestry, Snehal N; Gawali, Nitin B; Pai, Sarayu A; Gursahani, Malvika S; Dhodi, Jayesh B; Munshi, Renuka; Juvekar, Archana R

    2018-03-16

    Gentamicin is widely used as an antibiotic for the treatment of gram negative infections. Evidences indicates that oxidative stress is involved in gentamicin-induced nephrotoxicity. In Ayurvedic medicine, Punica granatum Linn. is considered as 'a pharmacy unto itself". It has been claimed in traditional literature, to treat various kidney ailments due to its antioxidant potential. To explore the possible mechanism of action of methanolic extract of P.granatum leaves (MPGL) in exerting a protective effect on gentamicin-induced nephropathy. Animals were administered with gentamicin (80 mg/kg/day i.m.) and simultaneously with MPGL (100, 200 and 400 mg/kg p.o.) or metformin (100 mg/kg p.o.) for 8 days. A satellite group was employed in order to check for reversibility of nephrotoxic effects post discontinuation of gentamicin administration. At the end of the study, all the rats were sacrificed and serum-urine parameters were investigated. Antioxidant enzymes and tumor necrosis factor alpha (TNF-α) levels were determined in the kidney tissues along with histopathological examination of kidneys. Increase in serum creatinine, urea, TNF-α, lipid peroxidation along with fall in the antioxidant enzymes activity and degeneration of tubules, arterioles as revealed by histopathological examination confirmed the manifestation of nephrotoxicity caused due to gentamicin. Simultaneous administration of MPGL and gentamicin protected kidneys against nephrotoxic effects of gentamicin as evidenced from normalization of renal function parameters and amelioration of histopathological changes. Data suggests that MPGL attenuated oxidative stress associated renal injury by preserving antioxidant enzymes, reducing lipid peroxidation and inhibiting inflammatory mediators such as TNF-α. Copyright © 2017 Transdisciplinary University, Bangalore and World Ayurveda Foundation. Published by Elsevier B.V. All rights reserved.

  20. Sildenafil Ameliorates Gentamicin-Induced Nephrotoxicity in Rats: Role of iNOS and eNOS

    Directory of Open Access Journals (Sweden)

    Mohamed A. Morsy

    2014-01-01

    Full Text Available Gentamicin, an aminoglycoside antibiotic, is used for the treatment of serious Gram-negative infections. However, its usefulness is limited by its nephrotoxicity. Sildenafil, a selective phosphodiesterase-5 inhibitor, was reported to prevent or decrease tissue injury. The aim of this study is to evaluate the potential protective effects of sildenafil on gentamicin-induced nephrotoxicity in rats. Male Wistar rats were injected with gentamicin (100 mg/kg/day, i.p. for 6 days with and without sildenafil. Sildenafil administration resulted in nephroprotective effect in gentamicin-intoxicated rats as it significantly decreased serum creatinine and urea, urinary albumin, and renal malondialdehyde and nitrite/nitrate levels, with a concomitant increase in renal catalase and superoxide dismutase activities compared to gentamicin-treated rats. Moreover, immunohistochemical examination revealed that sildenafil treatment markedly reduced inducible nitric oxide synthase (iNOS expression, while expression of endothelial nitric oxide synthase (eNOS was markedly enhanced. The protective effects of sildenafil were verified histopathologically. In conclusion, sildenafil protects rats against gentamicin-induced nephrotoxicity possibly, in part, through its antioxidant activity, inhibition of iNOS expression, and induction of eNOS production.

  1. Pentoxifylline Ameliorates Glomerular Basement Membrane Ultrastructural Changes Caused by Gentamicin Administration in Rats

    Directory of Open Access Journals (Sweden)

    Nenad Stojiljković

    2009-08-01

    Full Text Available Gentamicin is commonly used for the treatment of severe gram negative bacterial infections but inevi-tably cause renal failure during prolonged use. The aim of our study was to emphasize protective effects of pentoxifylline on glomerular basement membrane (GBM alterations induced by gentamicin in rats. Experiments were done on 40 male Wistar rats divided in three experimental groups. GM-group was treated daily with gentamicin in dose of 100 mg/kg during 8 days. PTX-group was treated daily with pentoxifylline in dose of 45 mg/kg and the same dose of gentamicin as in GM-group during 8 days. The control group received 1 ml/day saline intraperitoneally. Morphometric parameter measured during the analysis was glomerular basement membrane thickness. In GM-group of animals glomeruli were en-larged and GMB was diffusely and unequally thickened with neutrophil cells infiltration. In proximal tu-bules epithelial cells, vacuolization of cytoplasm with coagulation-type necrosis were observed. In PTX-group of animals glomeruli were somewhat enlarged and GBM was thickened only in some segments. Coagulation-type necrosis was not found. Blood urea and serum creatinine concentration in GM-group were significantly elevated in comparison with PTX-group while potassium level was decreased. Our results suggest that PTX has protective effects on GBM and proximal tubules in GM-treated rats.

  2. Lack of protection against gentamicin ototoxicity by auditory conditioning with noise

    Directory of Open Access Journals (Sweden)

    Alex Strose

    2014-10-01

    Full Text Available INTRODUCTION: Auditory conditioning consists of the pre-exposure to low levels of a potential harmful agent to protect against a subsequent harmful presentation. OBJECTIVE: To confirm if conditioning with an agent different from the used to cause the trauma can also be effective. METHOD: Experimental study with 17 guinea pigs divided as follows: group Som: exposed to 85 dB broadband noise centered at 4 kHz, 30 minutes a day for 10 consecutive days; group Cont: intramuscular administration of gentamicin 160 mg/kg a day for 10 consecutive days; group Expt: conditioned with noise similarly to group Som and, after each noise presentation, received gentamicin similarly to group Cont. The animals were evaluated by distortion product otoacoustic emissions (DPOAEs, brainstem auditory evoked potentials (BAEPs and scanning electron microscopy. RESULTS: The animals that were conditioned with noise did not show any protective effect compared to the ones that received only the ototoxic gentamicin administration. This lack of protection was observed functionally and morphologically. CONCLUSION: Conditioning with 85 dB broadband noise, 30 min a day for 10 consecutive days does not protect against an ototoxic gentamicin administration of 160 mg/kg a day for 10 consecutive days in the guinea pig.

  3. 21 CFR 524.1044a - Gentamicin ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gentamicin ophthalmic solution. 524.1044a Section... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1044a Gentamicin ophthalmic solution. (a) Specifications. Each milliliter of sterile aqueous...

  4. Instrumental characterization of the smectite clay–gentamicin hybrids

    Indian Academy of Sciences (India)

    This paper focusses on the intercalation of clay mineral with gentamicin (an aminoglycoside antibiotic). The smectite clay–gentamicin hybrids were prepared by a solution intercalation at 60°C and the process was carried out on unmodified smectite clay and on smectite after Na+ ionic activation. The resulting ...

  5. Enzymuria in neonates receiving continuous intravenous infusion of gentamicin

    DEFF Research Database (Denmark)

    Colding, H; Brygge, K; Brendstrup, L

    1992-01-01

    with non-treatment periods in the same newborn infant (33 infants). The same tendency applied to AAP. Newborn infants receiving continuous intravenous infusion of gentamicin were not found to be at greater risk of nephrotoxicity than those receiving intermittent gentamicin treatment, using NAG and AAP...

  6. Once versus twice daily gentamicin dosing for infective endocarditis

    DEFF Research Database (Denmark)

    Buchholtz, Kristine; Larsen, Carsten Toftager; Schaadt, Bente

    2011-01-01

    Objectives: The aim of this randomized study was to investigate the effects of once versus twice daily gentamicin dosing on renal function and measures of infectious disease in a population with infective endocarditis (IE). Methods: Seventy-one IE patients needing gentamicin treatment according...

  7. In vitro gentamicin release from commercially available calcium-phosphate bone substitutes influence of carrier type on duration of the release profile

    Directory of Open Access Journals (Sweden)

    Bronckers Antonius LJJ

    2006-02-01

    Full Text Available Abstract Background Polymethyl-methacrylate (PMMA beads releasing antibiotics are used extensively to treat osteomyelitis, but require surgical removal afterwards because they do not degrade. Methods As an alternative option, this report compares the in vitro gentamicin release profile from clinically used, biodegradable carrier-materials: six injectable cements and six granule-types. Cement cylinders and coated granules containing 3% gentamicin were submerged in dH2O and placed in a 48-sample parallel drug-release system. At regular intervals (30, 90, 180 min. and then every 24 h, for 21 days, the release fluid was exchanged and the gentamicin concentration was measured. The activity of released gentamicin was tested on Staphylococcus aureus. Results All combinations showed initial burst-release of active gentamicin, two cements had continuous-release (17 days. The relative release of all cements (36–85% and granules (30–62% was higher than previously reported for injectable PMMA-cements (up to 17% and comparable to other biodegradable carriers. From the cements residual gentamicin could be extracted, whereas the granules released all gentamicin that had adhered to the surface. Conclusion The high release achieved shows great promise for clinical application of these biodegradable drug-carriers. Using the appropriate combination, the required release profile (burst or sustained may be achieved.

  8. Effect of Taurine on the antimicrobial efficiency of Gentamicin

    Directory of Open Access Journals (Sweden)

    Islambulchilar Mina

    2011-12-01

    Full Text Available Context: Gentamicin is mainly used in severe infections caused by gram-negatives. However toxicity including nephrotoxicity and ototoxicity is one of the most important complications of its treatment. The production of free radicals seems to be involved in gentamicin toxicity mechanism. Taurine, a major intracellular free β-amino acid, is known to be an endogenous antioxidant. So potentially the co-therapy of taurine and gentamicin would reduce the adverse effects of the antibiotic. Objectives: In this study, we wished to know the effect of taurine on the antibiotic capacity of gentamicin. methods: strains of P. aeruginosa, E. coli, S. aureus and S. epidermidis were used as test organisms. Minimum inhibitory concentrations of gentamicin in the presence and absence of taurine at quantities from 40 to 2 mg/L were determined using macro-dilution method. Results: MICs were determined in the various concentrations of taurine for bacterial indicators. The MIC values of gentamicin for P. aeruginosa, S. aureus and E. coli remained unchanged in the values of 2.5, 5 and 20 μg/ml respectively in the absence and presences of different concentrations of taurine. The bactericidal activity of gentamicin against S. epidermidis was increased by addition of taurine in the concentrations higher than 6 mg/L. Conclusion: According to our study the antibacterial activity of gentamicin against the indicator microorganisms were not interfere with taurine at selected concentrations. Further in vivo studies are needed to establish if a combination of gentamicin and taurine would have the same effect.

  9. Decreased Expression of Na+/K+-ATPase, NHE3, NBC1, AQP1 and OAT in Gentamicin-induced Nephropathy

    Science.gov (United States)

    Bae, Woo Kyun; Lee, JongUn; Park, Jeong Woo; Bae, Eun Hui; Ma, Seong Kwon; Kim, Suhn Hee

    2008-01-01

    The present study was aimed to determine whether there is an altered regulation of tubular transporters in gentamicin-induced nephropathy. Sprague-Dawley male rats (200~250 g) were subcutaneously injected with gentamicin (100 mg/kg per day) for 7 days, and the expression of tubular transporters was determined by immunoblotting and immunohistochemistry. The mRNA and protein expression of OAT was also determined. Gentamicin-treated rats exhibited significantly decreased creatinine clearance along with increased plasma creatinine levels. Accordingly, the fractional excretion of sodium increased. Urine volume was increased, while urine osmolality and free water reabsorption were decreased. Immunoblotting and immunohistochemistry revealed decreased expression of Na+/K+-ATPase, NHE3, NBC1, and AQP1 in the kidney of gentamicin-treated rats. The expression of OAT1 and OAT3 was also decreased. Gentamicin-induced nephropathy may at least in part be causally related with a decreased expression of Na+/K+-ATPase, NHE3, NBC1, AQP1 and OAT. PMID:19967075

  10. Instrumental characterization of the smectite clay–gentamicin hybrids

    Indian Academy of Sciences (India)

    use of conventional drugs may lead to fluctuations whereby drug concentrations in ... ence of smectite, as well as determination of the capacity of gentamicin to fill ... the pharmaceutical and cosmetic industries manufactured by. R.T. Vanderbilt ...

  11. System-level musings about system-level science (Invited)

    Science.gov (United States)

    Liu, W.

    2009-12-01

    In teleology, a system has a purpose. In physics, a system has a tendency. For example, a mechanical system has a tendency to lower its potential energy. A thermodynamic system has a tendency to increase its entropy. Therefore, if geospace is seen as a system, what is its tendency? Surprisingly or not, there is no simple answer to this question. Or, to flip the statement, the answer is complex, or complexity. We can understand generally why complexity arises, as the geospace boundary is open to influences from the solar wind and Earth’s atmosphere and components of the system couple to each other in a myriad of ways to make the systemic behavior highly nonlinear. But this still begs the question: What is the system-level approach to geospace science? A reductionist view might assert that as our understanding of a component or subsystem progresses to a certain point, we can couple some together to understand the system on a higher level. However, in practice, a subsystem can almost never been observed in isolation with others. Even if such is possible, there is no guarantee that the subsystem behavior will not change when coupled to others. Hence, there is no guarantee that a subsystem, such as the ring current, has an innate and intrinsic behavior like a hydrogen atom. An absolutist conclusion from this logic can be sobering, as one would have to trace a flash of aurora to the nucleosynthesis in the solar core. The practical answer, however, is more promising; it is a mix of the common sense we call reductionism and awareness that, especially when strongly coupled, subsystems can experience behavioral changes, breakdowns, and catastrophes. If the stock answer to the systemic tendency of geospace is complexity, the objective of the system-level approach to geospace science is to define, measure, and understand this complexity. I will use the example of magnetotail dynamics to illuminate some key points in this talk.

  12. Nuclear systems of level measurement

    International Nuclear Information System (INIS)

    Lara, A.J.; Cabrera, M.J.

    1992-01-01

    In the industry there are processes in which is necessary to maintain the products level controlled which are handled for their transformation. The majority of such processes and by the operation conditions, they do not admit measure systems of level of invasive type then the application of nuclear techniques for level measurement results a big aid in these cases, since all the system installation is situated beyond frontiers of vessels that contain the product for measuring. In the Department of Nuclear Technology Applications of Mexican Petroleum Institute was developed a level measurement system by gamma rays transmission which operates in the Low Density Polyethylene plant of Petrochemical Complex Escolin at Poza Rica, Veracruz, Mexico. (Author)

  13. Space elevator systems level analysis

    Energy Technology Data Exchange (ETDEWEB)

    Laubscher, B. E. (Bryan E.)

    2004-01-01

    The Space Elevator (SE) represents a major paradigm shift in space access. It involves new, untried technologies in most of its subsystems. Thus the successful construction of the SE requires a significant amount of development, This in turn implies a high level of risk for the SE. This paper will present a systems level analysis of the SE by subdividing its components into their subsystems to determine their level of technological maturity. such a high-risk endeavor is to follow a disciplined approach to the challenges. A systems level analysis informs this process and is the guide to where resources should be applied in the development processes. It is an efficient path that, if followed, minimizes the overall risk of the system's development. systems level analysis is that the overall system is divided naturally into its subsystems, and those subsystems are further subdivided as appropriate for the analysis. By dealing with the complex system in layers, the parameter space of decisions is kept manageable. Moreover, A rational way to manage One key aspect of a resources are not expended capriciously; rather, resources are put toward the biggest challenges and most promising solutions. This overall graded approach is a proven road to success. The analysis includes topics such as nanotube technology, deployment scenario, power beaming technology, ground-based hardware and operations, ribbon maintenance and repair and climber technology.

  14. Clinicopathological Studies on Gentamicin Toxicity in White Leghorn Commercial Layers

    Directory of Open Access Journals (Sweden)

    Najam Ul Islam, M. Zargham Khan1, M. Kashif Saleemi*1, Ahrar Khan1, Sheraz Ahmed Bhatti1, Muhammad Yousaf2 and Zahoor-ul-Hassan3

    2011-10-01

    Full Text Available Gentamicin is an effective and economical drug used to control infectious diseases in poultry but is highly toxic and had slow clearance from the body. This study aimed to report three cases of gentamicin toxicity in three White Leghorn (WLH layer flocks in different poultry producing areas of Pakistan. In first case, gentamicin was injected in a 9000 WLH layer flock @ 10 mg/kg body weight (BW for seven times during 9-15 weeks for age. In second case, gentamicin was injected in a flock of 7500 WLH layers @ 25 mg/kg BW for four times during 17-18 weeks of age. In third case, gentamicin was injected in flock of 16000 WLH layers @ 22.22 mg/kg BW three times in 20-21 weeks of age. Flock wise mortality was 8.69, 82.63 and 71.86%, respectively. Birds were dehydrated, emaciated and had prominent keel bone. Clinical signs included dehydration, decreased body weight leading to emaciation, decreased feed intake, increased water intake and watery diarrhea. Necropsy revealed prominent keal bone, shrunken muscles swollen kidneys bulging out from bony sockets. Petechial and echymotic hemorrhages were present on heart and skeletal muscles. Liver was enlarged with hemorrhagic streaks on its surface. Microscopically, hemorrhages and acute tubular necrosis was recorded in kidneys. Liver had hemorrhages, cellular infiltration and vacuolar (fatty degeneration of hepatocytes. From the results, it could be concluded that overdosing and repeated administration of gentamicin was highly toxic to birds.

  15. Modeling Multi-Level Systems

    CERN Document Server

    Iordache, Octavian

    2011-01-01

    This book is devoted to modeling of multi-level complex systems, a challenging domain for engineers, researchers and entrepreneurs, confronted with the transition from learning and adaptability to evolvability and autonomy for technologies, devices and problem solving methods. Chapter 1 introduces the multi-scale and multi-level systems and highlights their presence in different domains of science and technology. Methodologies as, random systems, non-Archimedean analysis, category theory and specific techniques as model categorification and integrative closure, are presented in chapter 2. Chapters 3 and 4 describe polystochastic models, PSM, and their developments. Categorical formulation of integrative closure offers the general PSM framework which serves as a flexible guideline for a large variety of multi-level modeling problems. Focusing on chemical engineering, pharmaceutical and environmental case studies, the chapters 5 to 8 analyze mixing, turbulent dispersion and entropy production for multi-scale sy...

  16. Evaluation of three gentamicin serum assay techniques

    International Nuclear Information System (INIS)

    Matzke, G.R.; Gwizdala, C.; Wery, J.; Ferry, D.; Starnes, R.

    1982-01-01

    This investigation was designed to compare the enzyme-modified immunoassay (Syva--EMIT) with a radioimmunoassay (New England Nuclear--RIA) and the radiometric assay (Johnston--BACTEC) to determine the optimal assay for use in our aminoglycoside dosing service. The serum concentration determinations obtained via the three assay methods were analyzed by linear regression analysis. Significant positive correlations were noted between the three assay techniques (p less than 0.005) during both sample collection phases. The coefficients of determination for EMIT vs BACTEC and RIA vs BACTEC were 0.73 and 0.83 during phase 1, respectively, and 0.65 and 0.68 during phase 2, respectively. The slope of the regression lines also varied markedly during the two phases; 0.49 and 0.42 for EMIT and for RIA vs BACTEC, respectively, during phase 1 compound with 1.12 and 0.77, respectively, during phase 2. The differences noted in these relationships during phase 1 and 2 may be related to the alteration of the pH of the control sera utilized in the BACTEC assay. In contrast, RIA vs EMIT regression analysis indicated that existence of a highly significant relationship (p less than 0.0005 and r2 . 0.90). The EMIT technique was the easiest and most accurate for determination of serum gentamicin concentrations, whereas the BACTEC method was judged unacceptable for clinical use

  17. Tritium Labeled Gentamicin C: II.- Bioradiactive Degradation Products of Gentamicin by Catalytic H2O-3H Exchange Reaction

    International Nuclear Information System (INIS)

    Suarez, C.; Diaz, A.; Paz, D.; Jimeno, M. L.

    1992-01-01

    The main bio radioactive degradation products from catalytic hydrogen exchange of gentamicin C, (C1 + C2 + Cla) in basic form, are generated by N-demethylation in 3 - N and 6-N positions. Their structures were confirmed by 1HNMR and 13CNMR. These derivatives were fractionated by chromatography on silica gel. Antibacterial activities were similar to those of the parent antibiotics. Tritium exchange, under vacuum or nitrogen, is highly increased (4:1) when gentamicin are in basic form. In contrast with gentamicin sulfate, hydrolytic sub products as gramine, genta mines, garosamine and purpurosamines are practically absent. To properly optimize the exchange process, the composition of the gentamicin C complex must be taken into account. The exchange decreases in the order C2 > C1> Cla. Because of 6'-N-demethyl gentamicin C1 is C2, the radiochemical yield of C2 appears enhanced in the H2O-3H exchange of a mixture of them. Radioactivity distribution among the components and subunits of these three gentamicin were studied by strong and mild hydrolysis, and by methanolysis. (Author) 18 refs

  18. Tritium labeled Gentamicin C : II.- Bioradioactive products of Gentamicin by Catalytic H2O-3H exchange reaction

    International Nuclear Information System (INIS)

    Suarez, C.; Diaz, A.; Paz, D.; Jimeno, M.L.

    1992-01-01

    The main bioradioactive degradation products from catalytic hydrogen exchange of gentamicin C, (C1 + C2 + C1a) in basic form, are generated by N-dimethylations in 3 - N and 6'-N positions. Their structures were confirmed by HNMR and 13 CNMR. These derivatives were fractionated by chromatography on silica gel. Antibacterial activities were similar to those of the parent antibiotics. Tritium exchange, under vacuum or nitrogen, is highly increased (4:1) when gentamicina are in basic form. In contrast with gentamicin sulfate, hydrolytic subproducts as garamine, gentamicine, garosamine and purpurosamines are practically absent. To properly optimize the exchange process, the composition of the gentamicin C complex must be taken into account. The exchange decreases in the order C2 > C1 > C1a. Because of 6' -N-dimenthyl gentamicin C1 is C2, the radiochemical yield of C2 appears enhanced in the H 2 O- 3 H exchange of a mixture of them. Radioactivity distribution among the components and subunits of these three gentamicins were studied by stron and mild hydrolysis, and by methanolysis. (author)

  19. Treatment of infectious arthritis of the radiocarpal joint of cattle with gentamicin-impregnated collagen sponges

    International Nuclear Information System (INIS)

    Hirsbrunner, G.; Steiner, A.

    1998-01-01

    Gentamicin-impregnated collagen sponges were used successfully in the treatment of chronic septic arthritis of the radiocarpal joint in two cattle. Both animals were moderately to severely lame and refractory to systemic antibiotics, and one of them was refractory to joint lavage and local antibiotics. The clinical diagnosis was confirmed by radiography and arthrocentesis. Arthroscopy was performed under general anaesthesia and, after debridement and lavage of the joint, gentamicin-impregnated collagen sponges were placed intra-articularly. Synovial fluid was sampled at 10 and 20 days after surgery and radiographs were taken three months (case 1) and two months (case 2) after surgery. The infection was eliminated from both animals and they recovered without residual lameness

  20. Intraoperative intra-articular injection of gentamicin: will it decrease the risk of infection in total shoulder arthroplasty?

    Science.gov (United States)

    Lovallo, Jeffrey; Helming, Jarrett; Jafari, S Mehdi; Owusu-Forfie, Afia; Donovan, Skye; Minnock, Christopher; Adib, Farshad

    2014-09-01

    Deep infection is a debilitating complication after shoulder arthroplasty. Intra-articular injection of antibiotic can give a higher concentration compared with intravenous administration. We hypothesized that a group of patients given an intra-articular, intraoperative injection of gentamicin would report a lower infection rate than a group without local antibiotics. Between 2005 and 2011, the senior author performed 507 shoulder arthroplasties. We retrospectively reviewed all of those cases. All patients were administered systemic prophylactic antibiotics. Beginning in June 2007, patients were also injected with 160 mg of gentamicin in the glenohumeral joint at the end of their surgery. Patient records were examined for preexisting medical conditions, type of surgery, and presence of infection. Patients receiving surgery before 2007 were compared with those after to determine the effect of prophylactic gentamicin administration in preventing deep infection associated with surgery. All patients were observed for a minimum of 1 year. Of the 507 surgeries, 164 were performed before 2007 (without intra-articular injection of gentamicin; group A) and 343 were performed with addition of gentamicin (group B). In group A, 5 patients presented with infection (3.0%) compared with 1 in group B (0.29%). The gender, mean age, mean body mass index, and prevalence of comorbidities were similar between the groups. The data from this study support the conclusion that intra-articular intraoperative gentamicin administration may reduce postoperative infection. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  1. Electrolyte composition of renal tubular cells in gentamicin nephrotoxicity

    International Nuclear Information System (INIS)

    Matsuda, O.; Beck, F.X.; Doerge, A.T.; Thurau, K.

    1988-01-01

    The effect of long-term gentamicin administration on sodium, potassium, chloride and phosphorus concentrations was studied in individual rat renal tubular cells using electron microprobe analysis. Histological damage was apparent only in proximal tubular cells. The extent of damage was only mild after 7 days of gentamicin administration (60 mg/kg body wt/day) but much more pronounced after 10 days. GFR showed a progressive decline during gentamicin treatment. In non-necrotic proximal tubular cells, sodium was increased from 14.6 +/- 0.3 (mean +/- SEM) in controls to 20.6 +/- 0.4 after 7 and 22.0 +/- 0.8 mmol/kg wet wt after 10 days of gentamicin administration. Chloride concentration was higher only after 10 days (20.6 +/- 0.6 vs. 17.3 +/- 0.2 mmol/kg wet wt). Both cell potassium and phosphorus concentrations were diminished by 6 and 15, and by 8 and 25 mmol/kg wet wt after 7 and 10 days of treatment, respectively. In contrast, no major alterations in distal tubular cell electrolyte concentrations could be observed after either 7 or 10 days of gentamicin administration. As in proximal tubular cells, distal tubular cell phosphorus concentrations were, however, lowered by gentamicin treatment. These results clearly indicate that gentamicin exerts its main effect on proximal tubular cells. Decreased potassium and increased sodium and chloride concentrations were observed in proximal tubular cells exhibiting only mild histological damage prior to the onset of advanced tissue injury. Necrotic cells, on the other hand, showed widely variable intracellular electrolyte concentration patterns

  2. Evaluation of novel biomarkers of nephrotoxicity in Cynomolgus monkeys treated with gentamicin

    International Nuclear Information System (INIS)

    Gautier, Jean-Charles; Zhou, Xiaobing; Yang, Yi; Gury, Thierry; Qu, Zhe; Palazzi, Xavier; Léonard, Jean-François; Slaoui, Mohamed; Veeranagouda, Yaligara; Guizon, Isabelle; Boitier, Eric; Filali-Ansary, Aziz; Berg, Bart H.J. van den; Poetz, Oliver; Joos, Thomas; Zhang, Tianyi; Wang, Jufeng; Detilleux, Philippe; Li, Bo

    2016-01-01

    Most studies to evaluate kidney safety biomarkers have been performed in rats. This study was conducted in Cynomolgus monkeys in order to evaluate the potential usefulness of novel biomarkers of nephrotoxicity in this species. Groups of 3 males were given daily intramuscular injections of gentamicin, a nephrotoxic agent known to produce lesions in proximal tubules, at dose-levels of 10, 25, or 50 mg/kg/day for 10 days. Blood and 16-h urine samples were collected on Days − 7, − 3, 2, 4, 7, and at the end of the dosing period. Several novel kidney safety biomarkers were evaluated, with single- and multiplex immunoassays and in immunoprecipitation-LC/MS assays, in parallel to histopathology and conventional clinical pathology parameters. Treatment with gentamicin induced a dose-dependent increase in kidney tubular cell degeneration/necrosis, ranging from minimal to mild severity at 10 mg/kg/day, moderate at 25 mg/kg/day, and to severe at 50 mg/kg/day. The results showed that the novel urinary biomarkers, microalbumin, α1-microglobulin, clusterin, and osteopontin, together with the more traditional clinical pathology parameters, urinary total protein and N-acetyl-β-D-glucosaminidase (NAG), were more sensitive than blood urea nitrogen (BUN) and serum creatinine (sCr) to detect kidney injury in the monkeys given 10 mg/kg/day gentamicin for 10 days, a dose leading to an exposure which is slightly higher than the desired therapeutic exposure in clinics. Therefore, these urinary biomarkers represent non-invasive biomarkers of proximal tubule injury in Cynomolgus monkeys which may be potentially useful in humans. - Highlights: • Gentamicin induced kidney tubular cell degeneration/necrosis in Cynomolgus monkey • Urinary clusterin and osteopontin were sensitive biomarkers of kidney injury. • Microalbumin and α1-microglobulin in urine were also more sensitive than serum creatinine.

  3. Evaluation of novel biomarkers of nephrotoxicity in Cynomolgus monkeys treated with gentamicin

    Energy Technology Data Exchange (ETDEWEB)

    Gautier, Jean-Charles, E-mail: jean-charles.gautier@sanofi.com [Sanofi R& D, Vitry-sur-Seine (France); Zhou, Xiaobing [National Center for Safety Evaluation of Drugs (NCSED), National Institutes for Food and Drug Control, Beijing (China); Yang, Yi [Sanofi R& D, Bridgewater (United States); Gury, Thierry [Sanofi R& D, Vitry-sur-Seine (France); Qu, Zhe [National Center for Safety Evaluation of Drugs (NCSED), National Institutes for Food and Drug Control, Beijing (China); Palazzi, Xavier; Léonard, Jean-François; Slaoui, Mohamed; Veeranagouda, Yaligara; Guizon, Isabelle; Boitier, Eric; Filali-Ansary, Aziz [Sanofi R& D, Vitry-sur-Seine (France); Berg, Bart H.J. van den; Poetz, Oliver; Joos, Thomas [Natural and Medical Sciences Institute at the University Tübingen (Germany); Zhang, Tianyi [Frontage Laboratories, Shanghai (China); Wang, Jufeng [National Center for Safety Evaluation of Drugs (NCSED), National Institutes for Food and Drug Control, Beijing (China); Detilleux, Philippe [Sanofi R& D, Vitry-sur-Seine (France); Li, Bo, E-mail: libo@nifdc.org.cn [National Center for Safety Evaluation of Drugs (NCSED), National Institutes for Food and Drug Control, Beijing (China)

    2016-07-15

    Most studies to evaluate kidney safety biomarkers have been performed in rats. This study was conducted in Cynomolgus monkeys in order to evaluate the potential usefulness of novel biomarkers of nephrotoxicity in this species. Groups of 3 males were given daily intramuscular injections of gentamicin, a nephrotoxic agent known to produce lesions in proximal tubules, at dose-levels of 10, 25, or 50 mg/kg/day for 10 days. Blood and 16-h urine samples were collected on Days − 7, − 3, 2, 4, 7, and at the end of the dosing period. Several novel kidney safety biomarkers were evaluated, with single- and multiplex immunoassays and in immunoprecipitation-LC/MS assays, in parallel to histopathology and conventional clinical pathology parameters. Treatment with gentamicin induced a dose-dependent increase in kidney tubular cell degeneration/necrosis, ranging from minimal to mild severity at 10 mg/kg/day, moderate at 25 mg/kg/day, and to severe at 50 mg/kg/day. The results showed that the novel urinary biomarkers, microalbumin, α1-microglobulin, clusterin, and osteopontin, together with the more traditional clinical pathology parameters, urinary total protein and N-acetyl-β-D-glucosaminidase (NAG), were more sensitive than blood urea nitrogen (BUN) and serum creatinine (sCr) to detect kidney injury in the monkeys given 10 mg/kg/day gentamicin for 10 days, a dose leading to an exposure which is slightly higher than the desired therapeutic exposure in clinics. Therefore, these urinary biomarkers represent non-invasive biomarkers of proximal tubule injury in Cynomolgus monkeys which may be potentially useful in humans. - Highlights: • Gentamicin induced kidney tubular cell degeneration/necrosis in Cynomolgus monkey • Urinary clusterin and osteopontin were sensitive biomarkers of kidney injury. • Microalbumin and α1-microglobulin in urine were also more sensitive than serum creatinine.

  4. Effect of nephrotoxic treatment with gentamicin on rats chronically exposed to uranium.

    Science.gov (United States)

    Rouas, Caroline; Stefani, Johanna; Grison, Stéphane; Grandcolas, Line; Baudelin, Cédric; Dublineau, Isabelle; Pallardy, Marc; Gueguen, Yann

    2011-01-11

    Uranium is a radioactive heavy metal with a predominantly chemical toxicity, affecting especially the kidneys and more particularly the proximal tubular structure. Until now, few experimental studies have examined the effect of chronic low-dose exposure to uranium on kidney integrity: these mainly analyse standard markers such as creatinine and urea, and none has studied the effect of additional co-exposure to a nephrotoxic agent on rats chronically exposed to uranium. The aim of the present study is to examine the potential cumulative effect of treating uranium-exposed rats with a nephrotoxic drug. Neither physiological indicators (diuresis and creatinine clearance) nor standard plasma and urine markers (creatinine, urea and total protein) levels were deteriorated when uranium exposure was combined with gentamicin-induced nephrotoxicity. A histological study confirmed the preferential impact of gentamicin on the tubular structure and showed that uranium did not aggravate the histopathological renal lesions. Finally, the use of novel markers of kidney toxicity, such as KIM-1, osteopontin and kallikrein, provides new knowledge about the nephrotoxicity threshold of gentamicin, and allows us to conclude that under our experimental conditions, low dose uranium exposure did not induce signs of nephrotoxicity or enhance renal sensitivity to another nephrotoxicant. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Effect of nephrotoxic treatment with gentamicin on rats chronically exposed to uranium

    International Nuclear Information System (INIS)

    Rouas, Caroline; Stefani, Johanna; Grison, Stephane; Grandcolas, Line; Baudelin, Cedric; Dublineau, Isabelle; Pallardy, Marc; Gueguen, Yann

    2011-01-01

    Uranium is a radioactive heavy metal with a predominantly chemical toxicity, affecting especially the kidneys and more particularly the proximal tubular structure. Until now, few experimental studies have examined the effect of chronic low-dose exposure to uranium on kidney integrity: these mainly analyse standard markers such as creatinine and urea, and none has studied the effect of additional co-exposure to a nephrotoxic agent on rats chronically exposed to uranium. The aim of the present study is to examine the potential cumulative effect of treating uranium-exposed rats with a nephrotoxic drug. Neither physiological indicators (diuresis and creatinine clearance) nor standard plasma and urine markers (creatinine, urea and total protein) levels were deteriorated when uranium exposure was combined with gentamicin-induced nephrotoxicity. A histological study confirmed the preferential impact of gentamicin on the tubular structure and showed that uranium did not aggravate the histopathological renal lesions. Finally, the use of novel markers of kidney toxicity, such as KIM-1, osteopontin and kallikrein, provides new knowledge about the nephrotoxicity threshold of gentamicin, and allows us to conclude that under our experimental conditions, low dose uranium exposure did not induce signs of nephrotoxicity or enhance renal sensitivity to another nephrotoxicant.

  6. Principles for system level electrochemistry

    Science.gov (United States)

    Thaller, L. H.

    1986-01-01

    The higher power and higher voltage levels anticipated for future space missions have required a careful review of the techniques currently in use to preclude battery problems that are related to the dispersion characteristics of the individual cells. Not only are the out-of-balance problems accentuated in these larger systems, but the thermal management considerations also require a greater degree of accurate design. Newer concepts which employ active cooling techniques are being developed which permit higher rates of discharge and tighter packing densities for the electrochemical components. This paper will put forward six semi-independent principles relating to battery systems. These principles will progressively address cell, battery and finally system related aspects of large electrochemical storage systems.

  7. Partridge embryo pathology in relation to gentamicin-induced lesions

    Directory of Open Access Journals (Sweden)

    Hadi Tavakkoli

    2016-10-01

    Full Text Available Objective: To determine the macroscopic and microscopic lesions of various dosages of gentamicin in the partridge embryo. Methods: Fertile chukar partridge eggs were allocated into four groups. Group 1: salineinjected group whose individuals were administered by sterile physiological saline solution of 0.2 mL/egg inserted into yolk sac. Groups 2, 3 and 4 whose individuals were similarly administered by gentamicin sulfate at a dosage of 80 mg/kg egg-weight once, twice and three times, respectively. Results: Results showed that the embryos were congested and stunted in the gentamicininjected groups. Defects in feet, wings and feather development were accompanied by microscopic lesions in brain, meninges, heart, lungs, liver and kidneys. Histopathological lesions were noticed as edema, undeveloped tissues, necrosis and degeneration in the affected organs. Conclusions: Based on acquired results, it is concluded that gentamicin at above-described dosages causes toxicopathological effects to the partridge embryo in a dose dependent manner.

  8. Thymus morphometry of New Zealand White Rabbits treated with gentamicin

    Directory of Open Access Journals (Sweden)

    Matheus Henrique Magalhães Silva

    2010-09-01

    Full Text Available The aim of this study was to evaluate the morphometry of cortical and medullary thymic lobes individualized by determination of area (μm2, perimeter (μm, maximum and minimum diameter (μm and shape factor in New Zealand White rabbits. The spleens of ten rabbits treated with gentamicin and ten control rabbits (males and females were histologically processed. The gentamicin dosage and the time of administration of this aminoglicoside were according to therapeutic recommendation. This antibiotic did not cause any alteration in the morphometry of the spleen, and it seemed not to be an immunosuppressive drug.

  9. Thymus morphometry of New Zealand White Rabbits treated with gentamicin

    Directory of Open Access Journals (Sweden)

    Matheus Henrique Magalhães Silva

    2010-01-01

    Full Text Available The aim of this study was to evaluate the morphometry of cortical and medullary thymic lobes individualized by determination of area (µm2, perimeter (µm, maximum and minimum diameter (µm and shape factor in New Zealand White rabbits. The spleens of ten rabbits treated with gentamicin and ten control rabbits (males and females were histologically processed. The gentamicin dosage and the time of administration of this aminoglicoside were according to therapeutic recommendation. This antibiotic did not cause any alteration in the morphometry of the spleen, and it seemed not to be an immunosuppressive drug.

  10. An experimental design approach to the preparation of pegylated polylactide-co-glicolide gentamicin loaded microparticles for local antibiotic delivery

    Energy Technology Data Exchange (ETDEWEB)

    Dorati, Rossella; DeTrizio, Antonella; Genta, Ida; Grisoli, Pietro; Merelli, Alessia [Department of Drug Sciences, Viale Taramelli 12, University of Pavia, 27100, Pavia (Italy); Tomasi, Corrado [IENI CNR Lecco Unit, Via Promessi Sposi 29, 23900, Lecco (Italy); Conti, Bice, E-mail: bice.conti@unipv.it [Department of Drug Sciences, Viale Taramelli 12, University of Pavia, 27100, Pavia (Italy)

    2016-01-01

    The present paper takes into account the DOE application to the preparation process of biodegradable microspheres for osteomyelitis local therapy. With this goal gentamicin loaded polylactide-co-glycolide-co-polyethyleneglycol (PLGA-PEG) microspheres were prepared and investigated. Two preparation protocols (o/w and w/o/w) with different process conditions, and three PLGA-PEG block copolymers with different compositions of lactic and glycolic acids and PEG, were tested. A Design Of Experiment (DOE) screening design was applied as an approach to scale up manufacturing step. The results of DOE screening design confirmed that w/o/w technique, the presence of salt and the 15%w/v polymer concentration positively affected the EE% (72.1–97.5%), and span values of particle size distribution (1.03–1.23), while salt addition alone negatively affected the yield process. Process scale up resulted in a decrease of gentamicin EE% that can be attributed to the high volume of water used to remove PVA and NaCl residues. The results of in vitro gentamicin release study show prolonged gentamicin release up to three months from the microspheres prepared with salt addition in the dispersing phase; the behavior being consistent with their highly compact structure highlighted by scanning electron microscopy analysis. The prolonged release of gentamicin is maintained even after embedding the biodegradable microspheres into a thermosetting composite gel made of chitosan and acellular bovine bone matrix (Orthoss® granules), and the microbiologic evaluation demonstrated the efficacy of the gentamicin loaded microspheres on Escherichia coli. The collected results confirm the feasibility of the scale up of microsphere manufacturing process and the high potential of the microparticulate drug delivery system to be used for the local antibiotic delivery to bone. - Highlights: • To get a more effective therapy for the prevention and treatment of osteomyelitis. • To exploit the local

  11. Role of somatostatin receptor-2 in gentamicin-induced auditory hair cell loss in the Mammalian inner ear.

    Directory of Open Access Journals (Sweden)

    Yves Brand

    Full Text Available Hair cells and spiral ganglion neurons of the mammalian auditory system do not regenerate, and their loss leads to irreversible hearing loss. Aminoglycosides induce auditory hair cell death in vitro, and evidence suggests that phosphatidylinositol-3-kinase/Akt signaling opposes gentamicin toxicity via its downstream target, the protein kinase Akt. We previously demonstrated that somatostatin-a peptide with hormone/neurotransmitter properties-can protect hair cells from gentamicin-induced hair cell death in vitro, and that somatostatin receptors are expressed in the mammalian inner ear. However, it remains unknown how this protective effect is mediated. In the present study, we show a highly significant protective effect of octreotide (a drug that mimics and is more potent than somatostatin on gentamicin-induced hair cell death, and increased Akt phosphorylation in octreotide-treated organ of Corti explants in vitro. Moreover, we demonstrate that somatostatin receptor-1 knockout mice overexpress somatostatin receptor-2 in the organ of Corti, and are less susceptible to gentamicin-induced hair cell loss than wild-type or somatostatin-1/somatostatin-2 double-knockout mice. Finally, we show that octreotide affects auditory hair cells, enhances spiral ganglion neurite number, and decreases spiral ganglion neurite length.

  12. 77 FR 3598 - Ophthalmic and Topical Dosage Form New Animal Drugs; Gentamicin and Betamethasone Spray

    Science.gov (United States)

    2012-01-25

    ... veterinary prescription use of gentamicin sulfate and betamethasone valerate topical spray in dogs. DATES... Veterinary Medicine (HFV-170), Food and Drug Administration, 7500 Standish Pl., Rockville, MD 20855, (240... prescription use of Gentamicin Topical Spray (gentamicin sulfate and betamethasone valerate) in dogs. Sparhawk...

  13. Gentamicin-attenuated Leishmania infantum: a clinicopathological study in dogs.

    Science.gov (United States)

    Daneshvar, Hamid; Molaei, Mohammad M; Afshar, Reza Malekpour; Kamiabi, Hosein; Burchmore, Richard; Hagan, Paul; Phillips, R Stephen

    2009-05-15

    The clinicopathological changes following infection with an attenuated line of Leishmania infantum (L. infantum H-line) were evaluated in mixed breed dogs. Two groups of dogs were infected intravenously (i.v.) or intradermally (i.d.) with L. infantum H-line and two control groups were infected i.v. or i.d. with L. infantum wild-type (L. infantum WT). None of the dogs, which were infected i.v. or i.d. with L. infantum H-line, showed any abnormalities during the observation period. In contrast, two out of three dogs, which were infected i.v. with L. infantum WT, developed clinical signs of disease. In addition, no histopathological changes were seen in the liver and spleen of the dogs infected with the attenuated line of parasite, whereas the histopathological changes in the two dogs infected i.v. with L. infantum WT were severe in form and manifested by infiltration of high numbers of inflammatory cells. No promastigotes were found in cultures set up from spleens and livers of dogs infected with L. infantum H-line at 12 months post-infection, whereas promastigotes were seen in the spleen and liver cultures from 2 dogs infected i.v. with L. infantum WT. Serum levels of total IgG anti-Leishmania antibody were raised in all dogs. The antibody level in the serum of dogs infected i.v. with L. infantum WT was higher than that in dogs infected with L. infantum H-line. These results show no clinicopathological abnormalities in the dogs infected with gentamicin-attenuated L. infantum H-line. Moreover, L. infantum H-line induced IgG anti-Leishmania antibody in the dogs.

  14. Using Six Sigma to improve once daily gentamicin dosing and therapeutic drug monitoring performance.

    LENUS (Irish Health Repository)

    Egan, Sean

    2012-08-07

    BACKGROUND: Safe, effective therapy with the antimicrobial gentamicin requires good practice in dose selection and monitoring of serum levels. Suboptimal therapy occurs with breakdown in the process of drug dosing, serum blood sampling, laboratory processing and level interpretation. Unintentional underdosing may result. This improvement effort aimed to optimise this process in an academic teaching hospital using Six Sigma process improvement methodology. METHODS: A multidisciplinary project team was formed. Process measures considered critical to quality were defined, and baseline practice was examined through process mapping and audit. Root cause analysis informed improvement measures. These included a new dosing and monitoring schedule, and standardised assay sampling and drug administration timing which maximised local capabilities. Three iterations of the improvement cycle were conducted over a 24-month period. RESULTS: The attainment of serum level sampling in the required time window improved by 85% (p≤0.0001). A 66% improvement in accuracy of dosing was observed (p≤0.0001). Unnecessary dose omission while awaiting level results and inadvertent disruption to therapy due to dosing and monitoring process breakdown were eliminated. Average daily dose administered increased from 3.39 mg\\/kg to 4.78 mg\\/kg\\/day. CONCLUSIONS: Using Six Sigma methodology enhanced gentamicin usage process performance. Local process related factors may adversely affect adherence to practice guidelines for gentamicin, a drug which is complex to use. It is vital to adapt dosing guidance and monitoring requirements so that they are capable of being implemented in the clinical environment as a matter of routine. Improvement may be achieved through a structured localised approach with multidisciplinary stakeholder involvement.

  15. Protective Effect of Cinnamomum tamala Extract on Gentamicin ...

    African Journals Online (AJOL)

    Results: Gentamicin-treated animals showed significant renal damage as indicated by rise in blood ... mg/dl), urinary proteins (3.86 ± 0.32 mg/dl) and decrease in creatinine ... been used in folk medicine as brain tonic and ... also been reported with high phenolic contents ... maintained on the same diet and 12 h light/dark.

  16. Protective effect of hydroalcoholic extract of Pistacia vera against gentamicin-induced nephrotoxicity in rats.

    Science.gov (United States)

    Ehsani, Vahid; Amirteimoury, Morteza; Taghipour, Zahra; Shamsizadeh, Ali; Bazmandegan, Gholamreza; Rahnama, Amir; Khajehasani, Fatemeh; Fatemi, Iman

    2017-11-01

    Pistacia vera is a plant of the family Anacardiaceae found in Central and West Asia. P. vera nut (Pistachio) possess multiple pharmacological effects such as antimicrobial, anti-hyperlipidemia, antioxidant and anti-inflammatory. This study is designed to evaluate the protective effect of the hydroalcoholic extract of pistachio on gentamicin-induced nephrotoxicity in rats. Nephrotoxicity was induced in rats by intraperitoneal injection of gentamicin (100 mg/kg/day for 7 days). Hydroalcoholic extract of pistachio (10, 50 and 100 mg/kg/p.o) was administered for 7 days. The nephroprotective activity was evaluated by determining creatinine clearance, serum creatinine, urine volume, urine glucose and blood urea nitrogen (BUN) levels. The kidneys were processed for histopathological examinations and all specimens were examined for morphologic parameters involving tubular degeneration, tubular necrosis and tubule interstitial nephritis. Results showed a significant increase in the levels of serum creatinine, urine volume, urine glucose and BUN and decrease of creatinine clearance by gentamicin (GA) administration. Co-administration with pistachio extract showed reduction in the levels of serum creatinine, urine volume, urine glucose and BUN and increase of creatinine clearance in all doses but the most significant alteration was observed in doses of 100 mg/kg. Also, the nephroprotective effect of the GA was confirmed by the histological examination of the kidneys. The study revealed the nephroprotective effect of the hydroalcoholic extract of pistachio. These findings suggest that pistachio treatment may attenuate renal dysfunction and structural damage through the reduction of oxidative stress and inflammation in the kidney.

  17. Antibacterial Efficacy of a New Gentamicin-Coating for Cementless Prostheses Compared to Gentamicin-Loaded Bone Cement

    NARCIS (Netherlands)

    Neut, Danielle; Dijkstra, Rene J. B.; Thompson, Jonathan I.; van der Mei, Henny C.; Busscher, Henk J.

    Cementless prostheses are increasingly popular but require alternative prophylactic measures than the use of antibiotic-loaded bone cements. Here, we determine the 24-h growth inhibition of gentamicin-releasing coatings from grit-blasted and porous-coated titanium alloys, and compare their

  18. Pharmacokinetic modeling of gentamicin in treatment of infective endocarditis: Model development and validation of existing models

    Science.gov (United States)

    van der Wijk, Lars; Proost, Johannes H.; Sinha, Bhanu; Touw, Daan J.

    2017-01-01

    Gentamicin shows large variations in half-life and volume of distribution (Vd) within and between individuals. Thus, monitoring and accurately predicting serum levels are required to optimize effectiveness and minimize toxicity. Currently, two population pharmacokinetic models are applied for predicting gentamicin doses in adults. For endocarditis patients the optimal model is unknown. We aimed at: 1) creating an optimal model for endocarditis patients; and 2) assessing whether the endocarditis and existing models can accurately predict serum levels. We performed a retrospective observational two-cohort study: one cohort to parameterize the endocarditis model by iterative two-stage Bayesian analysis, and a second cohort to validate and compare all three models. The Akaike Information Criterion and the weighted sum of squares of the residuals divided by the degrees of freedom were used to select the endocarditis model. Median Prediction Error (MDPE) and Median Absolute Prediction Error (MDAPE) were used to test all models with the validation dataset. We built the endocarditis model based on data from the modeling cohort (65 patients) with a fixed 0.277 L/h/70kg metabolic clearance, 0.698 (±0.358) renal clearance as fraction of creatinine clearance, and Vd 0.312 (±0.076) L/kg corrected lean body mass. External validation with data from 14 validation cohort patients showed a similar predictive power of the endocarditis model (MDPE -1.77%, MDAPE 4.68%) as compared to the intensive-care (MDPE -1.33%, MDAPE 4.37%) and standard (MDPE -0.90%, MDAPE 4.82%) models. All models acceptably predicted pharmacokinetic parameters for gentamicin in endocarditis patients. However, these patients appear to have an increased Vd, similar to intensive care patients. Vd mainly determines the height of peak serum levels, which in turn correlate with bactericidal activity. In order to maintain simplicity, we advise to use the existing intensive-care model in clinical practice to avoid

  19. Pharmacokinetic modeling of gentamicin in treatment of infective endocarditis: Model development and validation of existing models.

    Directory of Open Access Journals (Sweden)

    Anna Gomes

    Full Text Available Gentamicin shows large variations in half-life and volume of distribution (Vd within and between individuals. Thus, monitoring and accurately predicting serum levels are required to optimize effectiveness and minimize toxicity. Currently, two population pharmacokinetic models are applied for predicting gentamicin doses in adults. For endocarditis patients the optimal model is unknown. We aimed at: 1 creating an optimal model for endocarditis patients; and 2 assessing whether the endocarditis and existing models can accurately predict serum levels. We performed a retrospective observational two-cohort study: one cohort to parameterize the endocarditis model by iterative two-stage Bayesian analysis, and a second cohort to validate and compare all three models. The Akaike Information Criterion and the weighted sum of squares of the residuals divided by the degrees of freedom were used to select the endocarditis model. Median Prediction Error (MDPE and Median Absolute Prediction Error (MDAPE were used to test all models with the validation dataset. We built the endocarditis model based on data from the modeling cohort (65 patients with a fixed 0.277 L/h/70kg metabolic clearance, 0.698 (±0.358 renal clearance as fraction of creatinine clearance, and Vd 0.312 (±0.076 L/kg corrected lean body mass. External validation with data from 14 validation cohort patients showed a similar predictive power of the endocarditis model (MDPE -1.77%, MDAPE 4.68% as compared to the intensive-care (MDPE -1.33%, MDAPE 4.37% and standard (MDPE -0.90%, MDAPE 4.82% models. All models acceptably predicted pharmacokinetic parameters for gentamicin in endocarditis patients. However, these patients appear to have an increased Vd, similar to intensive care patients. Vd mainly determines the height of peak serum levels, which in turn correlate with bactericidal activity. In order to maintain simplicity, we advise to use the existing intensive-care model in clinical practice to

  20. Integrated transcriptomic and proteomic evaluation of gentamicin nephrotoxicity in rats

    International Nuclear Information System (INIS)

    Com, Emmanuelle; Boitier, Eric; Marchandeau, Jean-Pierre; Brandenburg, Arnd; Schroeder, Susanne; Hoffmann, Dana; Mally, Angela; Gautier, Jean-Charles

    2012-01-01

    Gentamicin is an aminoglycoside antibiotic, which induces renal tubular necrosis in rats. In the context of the European InnoMed PredTox project, transcriptomic and proteomic studies were performed to provide new insights into the molecular mechanisms of gentamicin-induced nephrotoxicity. Male Wistar rats were treated with 25 and 75 mg/kg/day subcutaneously for 1, 3 and 14 days. Histopathology observations showed mild tubular degeneration/necrosis and regeneration and moderate mononuclear cell infiltrate after long-term treatment. Transcriptomic data indicated a strong treatment-related gene expression modulation in kidney and blood cells at the high dose after 14 days of treatment, with the regulation of 463 and 3241 genes, respectively. Of note, the induction of NF-kappa B pathway via the p38 MAPK cascade in the kidney, together with the activation of T-cell receptor signaling in blood cells were suggestive of inflammatory processes in relation with the recruitment of mononuclear cells in the kidney. Proteomic results showed a regulation of 163 proteins in kidney at the high dose after 14 days of treatment. These protein modulations were suggestive of a mitochondrial dysfunction with impairment of cellular energy production, induction of oxidative stress, an effect on protein biosynthesis and on cellular assembly and organization. Proteomic results also provided clues for potential nephrotoxicity biomarkers such as AGAT and PRBP4 which were strongly modulated in the kidney. Transcriptomic and proteomic data turned out to be complementary and their integration gave a more comprehensive insight into the putative mode of nephrotoxicity of gentamicin which was in accordance with histopathological findings. -- Highlights: ► Gentamicin induces renal tubular necrosis in rats. ► The mechanisms of gentamicin nephrotoxicity remain still elusive. ► Transcriptomic and proteomic analyses were performed to study this toxicity in rats. ► Transcriptomic and proteomic

  1. Effects of benfotiamine and coenzyme Q10 on kidney damage induced gentamicin.

    Science.gov (United States)

    Ustuner, Mehmet Alperen; Kaman, Dilara; Colakoglu, Neriman

    2017-12-01

    Gentamicin (GM) is an effective antibiotic against severe infection but has limitations related to nephrotoxicity. In this study, we investigated whether benfotiamine (BFT) and coenzyme Q10 (CoQ10), could ameliorate the nephrotoxic effect of GM in rats. Rats were divided into five groups. Group 1 and 2 served as control and sham respectively, Group 3 as GM group, Group 4 as GM+CoQ10 and Group 5 as GM+BFT for 8days. At the end of the study, all rats were euthanized by cervical decapitation and then blood samples and kidneys were collected for further analysis. Serum urea, creatinine, cytokine TNF-a, oxidant and antioxidant parameters, as well as histopathological examination of kidney tissues were assessed. Gentamicin administration caused a severe nephrotoxicity which was evidenced by an elevated serum creatinine, urea and KIM-1 level as compared with the controls. Moreover, a significant increase in serum malondialdehyde, reduced glutathione. Histopathological examination of renal tissue in gentamisin administered group, there were extremly pronounced necrotic tubules in the renal cortex and hyalen cast accumulation in the medullar tubuli. BFT given to GM rats reduced these nephrotoxicity parameters. Serum creatinine, urea, and KIM-1 were almost normalized in the GM+BFT group. Benfotiamin treatment was significantly decreased necrotic tubuli and hyalen deposition in gentamisin plus benfotiamin group. CoQ10 given to GM rats did not cause any statistically significant alterations in these nephrotoxicity parameters when compared with GM group but histopathological examination of renal tissue in GM+CoQ10 administered group, CoQ10 treatment was decreased necrotic tubuli rate and hyalen accumulation in tubuli. The results from our study indicate that BFT supplement attenuates gentamicin-induced renal injury via the amelioration of oxidative stress and inflammation of renal tubular cells. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Application of Box-Behnken design to prepare gentamicin-loaded calcium carbonate nanoparticles.

    Science.gov (United States)

    Maleki Dizaj, Solmaz; Lotfipour, Farzaneh; Barzegar-Jalali, Mohammad; Zarrintan, Mohammad-Hossein; Adibkia, Khosro

    2016-09-01

    The aim of this research was to prepare and optimize calcium carbonate (CaCO3) nanoparticles as carriers for gentamicin sulfate. A chemical precipitation method was used to prepare the gentamicin sulfate-loaded CaCO3 nanoparticles. A 3-factor, 3-level Box-Behnken design was used for the optimization procedure, with the molar ratio of CaCl2: Na2CO3 (X1), the concentration of drug (X2), and the speed of homogenization (X3) as the independent variables. The particle size and entrapment efficiency were considered as response variables. Mathematical equations and response surface plots were used, along with the counter plots, to relate the dependent and independent variables. The results indicated that the speed of homogenization was the main variable contributing to particle size and entrapment efficiency. The combined effect of all three independent variables was also evaluated. Using the response optimization design, the optimized Xl-X3 levels were predicted. An optimized formulation was then prepared according to these levels, resulting in a particle size of 80.23 nm and an entrapment efficiency of 30.80%. It was concluded that the chemical precipitation technique, together with the Box-Behnken experimental design methodology, could be successfully used to optimize the formulation of drug-incorporated calcium carbonate nanoparticles.

  3. Gentamicin binds to the megalin receptor as a competitive inhibitor using the common ligand binding motif of complement type repeats

    DEFF Research Database (Denmark)

    Dagil, Robert; O'Shea, Charlotte; Nykjær, Anders

    2013-01-01

    megalin and investigated its interaction with gentamicin. Using NMR titration data in HADDOCK, we have generated a three-dimensional model describing the complex between megalin and gentamicin. Gentamicin binds to megalin with low affinity and exploits the common ligand binding motif previously described...... to megalin is highly similar to gentamicin binding to calreticulin. We discuss the impact of this novel insight for the future structure-based design of gentamicin antagonists....

  4. Co-delivery of ibuprofen and gentamicin from nanoporous anodic titanium dioxide layers.

    Science.gov (United States)

    Pawlik, Anna; Jarosz, Magdalena; Syrek, Karolina; Sulka, Grzegorz D

    2017-04-01

    Although single-drug therapy may prove insufficient in treating bacterial infections or inflammation after orthopaedic surgeries, complex therapy (using both an antibiotic and an anti-inflammatory drug) is thought to address the problem. Among drug delivery systems (DDSs) with prolonged drug release profiles, nanoporous anodic titanium dioxide (ATO) layers on Ti foil are very promising. In the discussed research, ATO samples were synthesized via a three-step anodization process in an ethylene glycol-based electrolyte with fluoride ions. The third step lasted 2, 5 and 10min in order to obtain different thicknesses of nanoporous layers. Annealing the as-prepared amorphous layers at the temperature of 400°C led to obtaining the anatase phase. In this study, water-insoluble ibuprofen and water-soluble gentamicin were used as model drugs. Three different drug loading procedures were applied. The desorption-desorption-diffusion (DDD) model of the drug release was fitted to the experimental data. The effects of crystalline structure, depth of TiO 2 nanopores and loading procedure on the drug release profiles were examined. The duration of the drug release process can be easily altered by changing the drug loading sequence. Water-soluble gentamicin is released for a long period of time if gentamicin is loaded in ATO as the first drug. Additionally, deeper nanopores and anatase phase suppress the initial burst release of drugs. These results confirm that factors such as morphological and crystalline structure of ATO layers, and the procedure of drug loading inside nanopores, allow to alter the drug release performance of nanoporous ATO layers. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Developmental pharmacokinetics of gentamicin in preterm and term neonates

    DEFF Research Database (Denmark)

    Nielsen, Elisabet I; Sandström, Marie; Honoré, Per Hartvig

    2009-01-01

    0-45 days) were enrolled in the study. In total, 894 serum gentamicin samples were included in the analysis. The concentration-time profile was described using a three-compartment model. Gentamicin clearance increased with the GA and PNA (included in a nonlinear fashion). The GA was also identified...... in this patient population. METHODS: Data were collected in a prospective study performed in the Neonatal Intensive Care Unit at the University Children's Hospital, Uppsala, Sweden. Population pharmacokinetic modelling was performed using nonlinear mixed-effects modelling (NONMEM) software. Bodyweight...... was included as the primary covariate according to an allometric power model. Other evaluated covariates were age (postmenstrual age, gestational age [GA], postnatal age [PNA]), markers for renal function (serum creatinine, serum cystatin C) and concomitant medication with cefuroxime, vancomycin or indometacin...

  6. MICROMORPHOLOGICALCHARACTERISTICS OF THE LIVER AND BIOCHEMICAL ANALYSES IN THE BLOOD OF RATS TREATED BY GENTAMICIN AND VERAPAMIL

    Directory of Open Access Journals (Sweden)

    Milan Stoiljkovic

    2006-04-01

    Full Text Available The use of antimicrobial drugs, especially gentamicin and calcium blocker verapamil, may cause transitional functional damage of the liver.The aim of this study is to explore micro-morphological changes in the liver and biochemical changes in the blood of rats treated with gentamicin and verapamil. The research included 20 rats divided in experimental and control group. The experimental group (10 rats was treated with gentamicin (100 mg/kg/BW/24h and verapamil (3 mg/kgBW/24 h for 8 days. The control group (10 rats received physiological solution (1 ml/kgBW/24 h at the same time. We analyzed micro-morphological changes in the liver and biochemical parameters in blood: transaminase, bilirubin and glucose.In the control group, there was a normal lobular liver structure. All hepatocytes had polygonal shape, pink cytoplasm and the location of nucleus was central or paracentral. Biochemical blood analysis showed normal level of transaminase (SGOT 29.5 +/- 7.4 iu/l; SGPT 31.7 +/- 6.9 iu/l, total bilirubin (3.1 +/- 0.9 mmol/l and glucose (4.9 +/- 0.9 mmol/l. In the experimental group of animals, hepatocytes of all three zones were equally damaged. In the cytoplasm, we found vacuolar degeneration, reduced condensation of chromatine in nucleus and light nucleoplasm. Hepatocytes of the periportal zone had acidofillic degeneration, picnotic and hiperchromatic nuclei. Biochemical blood analysis showed high level of transaminase (SGOT 46.4 +/- 4.7 iu/l; SGPT 50.8+/-6.1 iu/l, total bilirubin (12.8+/-1.7 mmol/l and glucose (9.3+/-1.8 mmol/l. There is a statistically significant difference in biochemical parameters between the two groups (p < 0,001. The results of our experimental study suggest that there is an obvious correlation between application of gentamicin and verapamil and these changes.

  7. Camel Milk Beneficial Effects on Treating Gentamicin Induced Alterations in Rats

    Directory of Open Access Journals (Sweden)

    Abdulrahman K. Al-Asmari

    2014-01-01

    Full Text Available The potential effect of camel milk (CM against gentamicin (GM induced biochemical changes in the rat serum was evaluated. Four groups of six albino rats were used for control, CM fed, injected with GM(i.p., and then fed and injected with GM. The results showed that the administration of GM significantly altered the levels of aspartate aminotransferase (AST, alanine aminotransferase (ALT, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH activity in rat serum. CM restored these parameters to almost their normal range in group IV. Additionally, the present study showed that injection of rats with gentamicin caused an increase in malondialdehyde (MDA and myeloperoxidase (MPO activity while the antioxidant enzymes like superoxide dismutase (SOD and glutathione s-transferase (GST activity decreased significantly (P≤0.05. Administration of CM significantly (P≤0.05 inhibited the formation of MDA and activity of MPO and upregulated the antioxidant enzymes (SOD and GST activity. The overall findings of this study demonstrated that pretreatment with CM gave protection against GM induced hepatic damage possibly by inhibiting oxidative stress and inflammation, and hence camel milk can be identified as a new therapeutic agent.

  8. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    Directory of Open Access Journals (Sweden)

    D Neut

    2015-01-01

    Full Text Available A degradable, poly (lactic-co-glycolic acid (PLGA, gentamicin-loaded prophylactic coating for hydroxyapatite (HA-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial properties of this PLGA-gentamicin-HA-coating in different in vitro models to an evaluation of its efficacy in preventing implant-related infection in rabbits. Bone in-growth in the absence and presence of the coating was investigated in a canine model. The PLGA-gentamicin-HA-coating showed high-burst release, with antibacterial efficacy in agar-assays completely disappearing after 4 days, minimising risk of inducing antibiotic resistance. Gentamicin-sensitive and gentamicin-resistant staphylococci were killed by the antibiotic-loaded coating, in a simulated prosthesis-related interfacial gap. PLGA-gentamicin-HA-coatings prevented growth of bioluminescent staphylococci around a miniature-stem mounted in bacterially contaminated agar, as observed using bio-optical imaging. PLGA-gentamicin-HA-coated pins inserted in bacterially contaminated medullary canals in rabbits caused a statistically significant reduction in infection rates compared to HA-coated pins without gentamicin. Bone ingrowth to PLGA-gentamicin-HA-coated pins, in condylar defects of Beagle dogs was not impaired by the presence of the degradable, gentamicin-loaded coating. In conclusion, the PLGA-gentamicin-HA-coating constitutes an effective strategy for infection prophylaxis in cementless prostheses.

  9. Features, Events, and Processes: System Level

    Energy Technology Data Exchange (ETDEWEB)

    D. McGregor

    2004-04-19

    The primary purpose of this analysis is to evaluate System Level features, events, and processes (FEPs). The System Level FEPs typically are overarching in nature, rather than being focused on a particular process or subsystem. As a result, they are best dealt with at the system level rather than addressed within supporting process-level or subsystem level analyses and models reports. The System Level FEPs also tend to be directly addressed by regulations, guidance documents, or assumptions listed in the regulations; or are addressed in background information used in development of the regulations. This evaluation determines which of the System Level FEPs are excluded from modeling used to support the total system performance assessment for license application (TSPA-LA). The evaluation is based on the information presented in analysis reports, model reports, direct input, or corroborative documents that are cited in the individual FEP discussions in Section 6.2 of this analysis report.

  10. The information protection level assessment system implementation

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    Currently, the threat of various attacks increases significantly as automated systems become more widespread. On the basis of the conducted analysis the information protection level assessment system establishing objective was identified. The paper presents the information protection level assessment software implementation in the information system by applying the programming language C #. In conclusions the software features are identified and experimental results are represented.

  11. Protective Effect of Carvacrol on Renal Functional and Histopathological Changes in Gentamicin-Induced-Nephrotoxicity in Rats

    Directory of Open Access Journals (Sweden)

    Hassan Ahmadvand

    2016-04-01

    Full Text Available Background Nephrotoxicity is one of the most important side effects of the use of gentamicin sulphate (GS resulted in reactive oxygen species generation. Antioxidant compounds played effective roles in reduction of renal injuries caused by using of gentamicin. Carvacrol is a strong antioxidant compound. Objectives The aim of this study is to explore the effect of carvacrol inhibition in lesions of gentamicin-induced nephrotoxicity. Materials and Methods In this experimental study, 32 male mature Sprague-Dawley rats were divided into 4 groups of 8; group1: control, group 2 sham received daily carvacrol injection (74 mg/kg for 12 days, group 3 received daily GS injection (100 mg/kg for 12 days, group 4 received daily GS (100 mg/kg and carvacrol (74 mg/kg for 12 days. After 12 days, rats were anaesthetized, blood sample were obtained and kidneys were removed then stained with hematoxylin and eosin method and then were studied histophatologically. Serum creatinine and urea were measured. Results Flow treatment of nephrotoxic animals with carvacrol could significantly inhibit leukocyte infiltration (9.42% and tubular necrosis (38.18% in comparison with the nephrotoxic untreated group. Carvacrol significantly decreased the levels of urea and creatinine in treated group compared with the nephrotoxic untreated group. Conclusions The findings showed that carvacrol alleviates loss of leukocyte infiltration (9.42% and tubular necrosis and exerts beneficial effects on kidney function test in nephrotoxic group.

  12. Promoting system-level learning from project-level lessons

    International Nuclear Information System (INIS)

    Jong, Amos A. de; Runhaar, Hens A.C.; Runhaar, Piety R.; Kolhoff, Arend J.; Driessen, Peter P.J.

    2012-01-01

    A growing number of low and middle income nations (LMCs) have adopted some sort of system for environmental impact assessment (EIA). However, generally many of these EIA systems are characterised by a low performance in terms of timely information dissemination, monitoring and enforcement after licencing. Donor actors (such as the World Bank) have attempted to contribute to a higher performance of EIA systems in LMCs by intervening at two levels: the project level (e.g. by providing scoping advice or EIS quality review) and the system level (e.g. by advising on EIA legislation or by capacity building). The aims of these interventions are environmental protection in concrete cases and enforcing the institutionalisation of environmental protection, respectively. Learning by actors involved is an important condition for realising these aims. A relatively underexplored form of learning concerns learning at EIA system-level via project level donor interventions. This ‘indirect’ learning potentially results in system changes that better fit the specific context(s) and hence contribute to higher performances. Our exploratory research in Ghana and the Maldives shows that thus far, ‘indirect’ learning only occurs incidentally and that donors play a modest role in promoting it. Barriers to indirect learning are related to the institutional context rather than to individual characteristics. Moreover, ‘indirect’ learning seems to flourish best in large projects where donors achieved a position of influence that they can use to evoke reflection upon system malfunctions. In order to enhance learning at all levels donors should thereby present the outcomes of the intervention elaborately (i.e. discuss the outcomes with a large audience), include practical suggestions about post-EIS activities such as monitoring procedures and enforcement options and stimulate the use of their advisory reports to generate organisational memory and ensure a better information

  13. Promoting system-level learning from project-level lessons

    Energy Technology Data Exchange (ETDEWEB)

    Jong, Amos A. de, E-mail: amosdejong@gmail.com [Innovation Management, Utrecht (Netherlands); Runhaar, Hens A.C., E-mail: h.a.c.runhaar@uu.nl [Section of Environmental Governance, Utrecht University, Utrecht (Netherlands); Runhaar, Piety R., E-mail: piety.runhaar@wur.nl [Organisational Psychology and Human Resource Development, University of Twente, Enschede (Netherlands); Kolhoff, Arend J., E-mail: Akolhoff@eia.nl [The Netherlands Commission for Environmental Assessment, Utrecht (Netherlands); Driessen, Peter P.J., E-mail: p.driessen@geo.uu.nl [Department of Innovation and Environment Sciences, Utrecht University, Utrecht (Netherlands)

    2012-02-15

    A growing number of low and middle income nations (LMCs) have adopted some sort of system for environmental impact assessment (EIA). However, generally many of these EIA systems are characterised by a low performance in terms of timely information dissemination, monitoring and enforcement after licencing. Donor actors (such as the World Bank) have attempted to contribute to a higher performance of EIA systems in LMCs by intervening at two levels: the project level (e.g. by providing scoping advice or EIS quality review) and the system level (e.g. by advising on EIA legislation or by capacity building). The aims of these interventions are environmental protection in concrete cases and enforcing the institutionalisation of environmental protection, respectively. Learning by actors involved is an important condition for realising these aims. A relatively underexplored form of learning concerns learning at EIA system-level via project level donor interventions. This 'indirect' learning potentially results in system changes that better fit the specific context(s) and hence contribute to higher performances. Our exploratory research in Ghana and the Maldives shows that thus far, 'indirect' learning only occurs incidentally and that donors play a modest role in promoting it. Barriers to indirect learning are related to the institutional context rather than to individual characteristics. Moreover, 'indirect' learning seems to flourish best in large projects where donors achieved a position of influence that they can use to evoke reflection upon system malfunctions. In order to enhance learning at all levels donors should thereby present the outcomes of the intervention elaborately (i.e. discuss the outcomes with a large audience), include practical suggestions about post-EIS activities such as monitoring procedures and enforcement options and stimulate the use of their advisory reports to generate organisational memory and ensure a better

  14. System level ESD co-design

    CERN Document Server

    Gossner, Harald

    2015-01-01

    An effective and cost efficient protection of electronic system against ESD stress pulses specified by IEC 61000-4-2 is paramount for any system design. This pioneering book presents the collective knowledge of system designers and system testing experts and state-of-the-art techniques for achieving efficient system-level ESD protection, with minimum impact on the system performance. All categories of system failures ranging from ‘hard’ to ‘soft’ types are considered to review simulation and tool applications that can be used. The principal focus of System Level ESD Co-Design is defining and establishing the importance of co-design efforts from both IC supplier and system builder perspectives. ESD designers often face challenges in meeting customers' system-level ESD requirements and, therefore, a clear understanding of the techniques presented here will facilitate effective simulation approaches leading to better solutions without compromising system performance. With contributions from Robert Asht...

  15. Darboux transformation for two-level system

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.; Baldiotti, M.; Gitman, D.; Shamshutdinova, V. [Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318-CEP, 05315-970 Sao Paulo, S.P. (Brazil)

    2005-06-01

    We develop the Darboux procedure for the case of the two-level system. In particular, it is demonstrated that one can construct the Darboux intertwining operator that does not violate the specific structure of the equations of the two-level system, transforming only one real potential into another real potential. We apply the obtained Darboux transformation to known exact solutions of the two-level system. Thus, we find three classes of new solutions for the two-level system and the corresponding new potentials that allow such solutions. (Abstract Copyright [2005], Wiley Periodicals, Inc.)

  16. Microsomal protein synthesis inhibition: an early manifestation of gentamicin nephrotoxicity

    International Nuclear Information System (INIS)

    Bennett, W.M.; Mela-Riker, L.M.; Houghton, D.C.; Gilbert, D.N.; Buss, W.C.

    1988-01-01

    Aminoglycoside antibiotics achieve bacterial killing by binding to bacterial ribosomes and inhibiting protein synthesis. To examine whether similar mechanisms could be present in renal tubular cells prior to the onset of overt proximal tubular necrosis due to these drugs, we isolated microsomes from Fischer rats given 20 mg/kg gentamicin every 12 h subcutaneously for 2 days and from vehicle-injected controls. Concomitant studies of renal structure, function, and mitochondrial respiration were carried out. [3H]leucine incorporation into renal microsomes of treated animals was reduced by 21.9% (P less than 0.01), whereas brain and liver microsomes from the same animals were unaffected. Gentamicin concentration in the renal microsomal preparation was 56 micrograms/ml, a value 7- to 10-fold above concentrations necessary to inhibit bacterial growth. Conventional renal function studies were normal (blood urea, serum creatinine, creatinine clearance). Treated animals showed only a mild reduction of inulin clearance, 0.71 compared with 0.93 ml.min-1.100 g-1 in controls (P less than 0.05), and an increase in urinary excretion of N-acetylglucosaminidase of 20 compared with 14.8 units/l (P less than 0.05). Renal slice transport of p-aminohippuric acid, tetraethylammonium, and the fractional excretion of sodium were well preserved. There was no evidence, as seen by light microscopy, of proximal tubular necrosis. Mitochondrial cytochrome concentrations were normal and respiratory activities only slightly reduced. Processes similar to those responsible for bacterial killing could be involved in experimental gentamicin nephrotoxicity before overt cellular necrosis

  17. Packaged low-level waste verification system

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, K.; Winberg, M.R.; McIsaac, C.V. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1995-12-31

    The Department of Energy through the National Low-Level Waste Management Program and WMG Inc. have entered into a joint development effort to design, build, and demonstrate the Packaged Low-Level Waste Verification System. Currently, states and low-level radioactive waste disposal site operators have no method to independently verify the radionuclide content of packaged low-level waste that arrives at disposal sites for disposition. At this time, the disposal site relies on the low-level waste generator shipping manifests and accompanying records to ensure that low-level waste received meets the site`s waste acceptance criteria. The subject invention provides the equipment, software, and methods to enable the independent verification of low-level waste shipping records to ensure that the site`s waste acceptance criteria are being met. The objective of the prototype system is to demonstrate a mobile system capable of independently verifying the content of packaged low-level waste.

  18. State level operations and interaction with facility level systems

    International Nuclear Information System (INIS)

    Bellinger, J.

    1989-01-01

    The role of the State System of Accounting for and Control of Nuclear Materials at the State level, particularly the role of the National Authority, in ensuring that both national and international safeguards objectives are met is discussed. The legislative basis for the National Authority is examined. The activities of Australia's National Authority - the Australian Safeguards Office - are described

  19. System level modeling and component level control of fuel cells

    Science.gov (United States)

    Xue, Xingjian

    This dissertation investigates the fuel cell systems and the related technologies in three aspects: (1) system-level dynamic modeling of both PEM fuel cell (PEMFC) and solid oxide fuel cell (SOFC); (2) condition monitoring scheme development of PEM fuel cell system using model-based statistical method; and (3) strategy and algorithm development of precision control with potential application in energy systems. The dissertation first presents a system level dynamic modeling strategy for PEM fuel cells. It is well known that water plays a critical role in PEM fuel cell operations. It makes the membrane function appropriately and improves the durability. The low temperature operating conditions, however, impose modeling difficulties in characterizing the liquid-vapor two phase change phenomenon, which becomes even more complex under dynamic operating conditions. This dissertation proposes an innovative method to characterize this phenomenon, and builds a comprehensive model for PEM fuel cell at the system level. The model features the complete characterization of multi-physics dynamic coupling effects with the inclusion of dynamic phase change. The model is validated using Ballard stack experimental result from open literature. The system behavior and the internal coupling effects are also investigated using this model under various operating conditions. Anode-supported tubular SOFC is also investigated in the dissertation. While the Nernst potential plays a central role in characterizing the electrochemical performance, the traditional Nernst equation may lead to incorrect analysis results under dynamic operating conditions due to the current reverse flow phenomenon. This dissertation presents a systematic study in this regard to incorporate a modified Nernst potential expression and the heat/mass transfer into the analysis. The model is used to investigate the limitations and optimal results of various operating conditions; it can also be utilized to perform the

  20. Determination of the effects of levofloxacin on gentamicin induced nephrotoxicity in rabbits: a comparative study

    International Nuclear Information System (INIS)

    Naeem, U.; Jamal, S.; Waheed, A.

    2015-01-01

    Objective: To determine the effects of levofloxacin on gentamicin induced nephrotoxicity in rabbits. Study Design: Comparative experimental study. Place and Duration of Study: The animal house of Army Medical College, Rawalpindi, and the pathology department of Army Medical College, Rawalpindi, from July 2009 to January 2010. Material and Methods: The effects of levofloxacin on gentamicin-induced nephrotoxicity were evaluated in rabbits. Twenty four rabbits were used in this study which were randomly divided into four groups (n= 6 in each group). Six animals were injected for 15 days with saline (NaCl; 0.9%), six with gentamicin alone at doses of 20 mg/kg of body weight/12 h (intramuscularly), six with combination of gentamicin (20 mg/kg/12 h) with low therapeutic doses of levofloxacin (30 mg/kg/24 h) and the last six were treated with gentamicin and high therapeutic doses of levofloxacin (50 mg/kg/24 h). Levofloxacin was given by intraperitoneal route. Results: Gentamicin induced nephrotoxicity was evaluated by histopathological and serum analysis. The extent of nephrotoxicity was significantly increased when gentamicin was given in combination with levofloxacin both in low and high doses. Conclusion: Levofloxacin enhances gentamicin induced nephrotoxicity and extent of this nephrotoxicity increased with increasing dose of levofloxacin. (author)

  1. Surface roughness, porosity and wettability of gentamicin-loaded bone cements and their antibiotic release

    NARCIS (Netherlands)

    van de Belt, H; Neut, D; Uges, DRA; Schenk, W; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    2000-01-01

    In this study, the release of gentamicin as a function of time was measured for six different gentamicin-loaded bone cements and related with the surface roughness, porosity and wettability of the cements. Initial release rates varied little between the six bone cements (CMW1, CMW3, CMW Endurance,

  2. The Effects of Zataria Multiflora Hydroalcoholic Extract on Gentamicin Induced Nephrotoxicity in Rats

    Directory of Open Access Journals (Sweden)

    Saeed Hajihashemi

    2015-07-01

    Full Text Available Abstract Background: Gentamicin is an aminoglycoside antibiotic that broadly is used to treat gram negative bacteria infections, although it has side effects such as nephrotoxicity. According to antioxidant, anti-inflammatory and vasodilatory properties of Zataria Multiflora, the effects of co-treatment with zataria Multiflora and hydroalcholic extract on gentamicin induced nephrotoxicitj were investigated. Materials and Methods: In this study, male rats of Vistar race were divided into 4 groups: 1.control group, 2. co-treatment with gentamicin and vehicle group, 3. co-treatment with gentamicin and zataria Multifiora extract group, 4. co-treatment with zataria Multiflora extract and normal saline solution group. Zataria Multiflora hydroalcoholic extract was added to drinking water as 800 PPm concentration. They, systolic blood pressure and renal blood flow (RBF were measured. Also, the amounts of urea, creatinine, sodium, potassium and osmolarity were measured in plasma and urine samples Results: In co-treatment group with zataria Multiflora extract, the amounts of urea, creatinine, absolute sodium excretion and relative sodium and potassium excretion and malondialdehyde (MDA that have been inceased in treatment with gentamicin, significantly were reduced. Creatinine clearance, urine osmolarity, RBF and FRAP that was decreased in gentamicin group in compare to control group, significantly increased. Conclusion: Co-treatment prevents nephrotoxicity induced by gentamicin and attenuates oxidative-stress associated renal injury by reducing oxygen free radicals and lipid peroxidation, So it can be effective to cure rats receiving gentamicin.

  3. Concentration gradient along the scala tympani after local application of gentamicin to the round window membrane.

    Science.gov (United States)

    Plontke, Stefan K; Mynatt, Robert; Gill, Ruth M; Borgmann, Stefan; Salt, Alec N

    2007-07-01

    The distribution of gentamicin along the fluid spaces of the cochlea after local applications has never previously been demonstrated. Computer simulations have predicted that significant basal-apical concentration gradients might be expected, and histologic studies indicate that hair cell damage is greater at the base than at the apex after local gentamicin application. In the present study, gradients of gentamicin along the cochlea were measured. A recently developed method of sampling perilymph from the cochlear apex of guinea pigs was used in which the samples represent fluid originating from different regions along the scala tympani. Gentamicin concentration was determined in sequential apical samples that were taken after up to 3 hours of local application to the round window niche. Substantial gradients of gentamicin along the length of the scala tympani were demonstrated and quantified, averaging more than 4,000 times greater concentration at the base compared with the apex at the time of sampling. Peak concentrations and gradients for gentamicin varied considerably between animals, likely resulting from variations in round window membrane permeability and rates of perilymph flow. The large gradients for gentamicin demonstrated here in guinea pigs account for how it is possible to suppress vestibular function in some patients with a local application of gentamicin without damaging auditory function. Variations in round window membrane permeability and in perilymph flow could account for why hearing losses are observed in some patients.

  4. Concentration gradient along scala tympani following the local application of gentamicin to the round window membrane

    Science.gov (United States)

    Plontke, Stefan K.; Mynatt, Robert; Gill, Ruth M.; Borgmann, Stefan; Salt, Alec N.

    2008-01-01

    Objectives The distribution of gentamicin along the fluid spaces of the cochlea following local applications has never previously been demonstrated. Computer simulations have predicted that significant basal-apical concentration gradients might be expected and histological studies indicate that hair cell damage is greater at the base than at the apex following local gentamicin application. In the present study, gradients of gentamicin along the cochlea were measured. Methods A recently-developed method of sampling perilymph from the cochlear apex of guinea pigs was used, in which the samples represent fluid originating from different regions along scala tympani. Gentamicin concentration was determined in sequential apical samples which were taken following up to three hours of local application to the round window niche. Results Substantial gradients of gentamicin along the length of scala tympani were demonstrated and quantified, averaging more than 4000 times greater concentration at the base compared to the apex at the time of sampling. Peak concentrations and gradients for gentamicin varied considerably between animals, likely resulting from variations in round window membrane permeability and rates of perilymph flow. Conclusions The large gradients for gentamicin demonstrated here in guinea pigs account for how it is possible to suppress vestibular function in some patients with a local application of gentamicin without damaging auditory function. Variations in round window membrane permeability and in perilymph flow could account for why hearing losses are observed in some patients. PMID:17603318

  5. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    NARCIS (Netherlands)

    Neut, D.; Dijkstra, R. J. B.; Thompson, J. I.; Kavanagh, C.; van der Mei, H. C.; Busscher, H. J.

    2015-01-01

    A degradable, poly (lactic-co-glycolic acid) (PLGA), gentamicin-loaded prophylactic coating for hydroxyapatite (HA)-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We

  6. Transdermal delivery of gentamicin using dissolving microneedle arrays for potential treatment of neonatal sepsis.

    Science.gov (United States)

    González-Vázquez, Patricia; Larrañeta, Eneko; McCrudden, Maelíosa T C; Jarrahian, Courtney; Rein-Weston, Annie; Quintanar-Solares, Manjari; Zehrung, Darin; McCarthy, Helen; Courtenay, Aaron J; Donnelly, Ryan F

    2017-11-10

    Neonatal infections are a leading cause of childhood mortality in low-resource settings. World Health Organization guidelines for outpatient treatment of possible serious bacterial infection (PSBI) in neonates and young infants when referral for hospital treatment is not feasible include intramuscular gentamicin (GEN) and oral amoxicillin. GEN is supplied as an aqueous solution of gentamicin sulphate in vials or ampoules and requires health care workers to be trained in dose calculation or selection of an appropriate dose based on the patient's weight band and to have access to safe injection supplies and appropriate sharps disposal. A simplified formulation, packaging, and delivery method to treat PSBI in low-resource settings could decrease user error and expand access to lifesaving outpatient antibiotic treatment for infants with severe infection during the neonatal period. We developed dissolving polymeric microneedles (MN) arrays to deliver GEN transdermally. MN arrays were produced from aqueous blends containing 30% (w/w) of GEN and two polymers approved by the US Food and Drug Administration: sodium hyaluronate and poly(vinylpyrrolidone). The arrays (19×19 needles and 500μm height) were mechanically strong and were able to penetrate a skin simulant to a depth of 378μm. The MN arrays were tested in vitro using a Franz Cell setup delivering approximately 4.45mg of GEN over 6h. Finally, three different doses (low, medium, and high) of GEN delivered by MN arrays were tested in an animal model. Maximum plasma levels of GEN were dose-dependent and ranged between 2 and 5μg/mL. The time required to reach these levels post-MN array application ranged between 1 and 6h. This work demonstrated the potential of dissolving MN arrays to deliver GEN transdermally at therapeutic levels in vivo. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Analyzing the Biology on the System Level

    OpenAIRE

    Tong, Wei

    2016-01-01

    Although various genome projects have provided us enormous static sequence information, understanding of the sophisticated biology continues to require integrating the computational modeling, system analysis, technology development for experiments, and quantitative experiments all together to analyze the biology architecture on various levels, which is just the origin of systems biology subject. This review discusses the object, its characteristics, and research attentions in systems biology,...

  8. Gentamicin-loaded poly(lactic-co-glycolic acid) microparticles for the prevention of maxillofacial and orthopedic implant infections

    International Nuclear Information System (INIS)

    Flores, Claudia; Degoutin, Stephanie; Chai, Feng; Raoul, Gwenael; Hornez, Jean-Chritophe; Martel, Bernard; Siepmann, Juergen; Ferri, Joel; Blanchemain, Nicolas

    2016-01-01

    Trauma and orthopedic surgery can cause infections as any open surgical procedures. Such complications occur in only1 to 5% of the cases, but the treatment is rather complicated due to bacterial biofilm formation and limited drug access to the site of infection upon systemic administration. An interesting strategy to overcome this type of complications is to prevent bacterial proliferation and biofilm formation via the local and controlled release of antibiotic drugs from the implant itself. Obviously, the incorporation of the drug into the implant should not affect the latter's biological and mechanical properties. In this context, we optimized the preparation process for gentamicin-loaded poly(lactic-co-glycolic acid) (PLGA) microparticles, which can be incorporated in the macropores of calcium phosphate-based bone substitutes. Microparticles were prepared using a double emulsion solvent extraction/evaporation technique. The processing parameters were optimized in order to provide an average microparticle size of about 60 μm, allowing for incorporation inside the macropores (100 μm) of the hydroxyapatite scaffold. Gentamicin-loaded PLGA microparticles showed a sustained release for 25–30 days and a rapid antibacterial activity due to a burst effect, the extent of which was controlled by the initial loading of the microparticles. SEM pictures revealed a highly porous microparticle structure, which can help to reduce the micro environmental pH drop and autocatalytic effects. The biological evaluation showed the cytocompatibility and non-hemolytic property of the microparticles, and the antibacterial activity against Staphylococcus aureus under the given conditions. - Highlights: • The optimization of microparticle preparation parameters allows to obtain a size compatible with the bone substitute porosity • PDL% has a direct impact on the burst effect, a control release of gentamicin was obtained • The incorporation of microparticles into the macroporosity

  9. Gentamicin-loaded poly(lactic-co-glycolic acid) microparticles for the prevention of maxillofacial and orthopedic implant infections

    Energy Technology Data Exchange (ETDEWEB)

    Flores, Claudia [Univ. Lille, 59000 Lille (France); INSERM U1008, Controlled Drug Delivery Systems and Biomaterials, 59000 Lille (France); Degoutin, Stephanie [Univ. Lille, 59000 Lille (France); UMET, Ingénierie des Systèmes Polymères, Université de Lille 1, 59655 Villeneuve d' Ascq (France); Chai, Feng [Univ. Lille, 59000 Lille (France); INSERM U1008, Controlled Drug Delivery Systems and Biomaterials, 59000 Lille (France); Raoul, Gwenael [Univ. Lille, 59000 Lille (France); INSERM U1008, Controlled Drug Delivery Systems and Biomaterials, 59000 Lille (France); Service Chirurgie Maxillo-Faciale, CHRU de Lille, 59000 Lille (France); Hornez, Jean-Chritophe [Laboratoire des Matériaux Céramiques et Procédés Associés (LMCPA), Université de Valenciennes, 59300 Valenciennes (France); Martel, Bernard [Univ. Lille, 59000 Lille (France); UMET, Ingénierie des Systèmes Polymères, Université de Lille 1, 59655 Villeneuve d' Ascq (France); Siepmann, Juergen [Univ. Lille, 59000 Lille (France); INSERM U1008, Controlled Drug Delivery Systems and Biomaterials, 59000 Lille (France); Ferri, Joel [Univ. Lille, 59000 Lille (France); INSERM U1008, Controlled Drug Delivery Systems and Biomaterials, 59000 Lille (France); Service Chirurgie Maxillo-Faciale, CHRU de Lille, 59000 Lille (France); Blanchemain, Nicolas, E-mail: nicolas.blanchemain@univ-lille2.fr [Univ. Lille, 59000 Lille (France); INSERM U1008, Controlled Drug Delivery Systems and Biomaterials, 59000 Lille (France)

    2016-07-01

    Trauma and orthopedic surgery can cause infections as any open surgical procedures. Such complications occur in only1 to 5% of the cases, but the treatment is rather complicated due to bacterial biofilm formation and limited drug access to the site of infection upon systemic administration. An interesting strategy to overcome this type of complications is to prevent bacterial proliferation and biofilm formation via the local and controlled release of antibiotic drugs from the implant itself. Obviously, the incorporation of the drug into the implant should not affect the latter's biological and mechanical properties. In this context, we optimized the preparation process for gentamicin-loaded poly(lactic-co-glycolic acid) (PLGA) microparticles, which can be incorporated in the macropores of calcium phosphate-based bone substitutes. Microparticles were prepared using a double emulsion solvent extraction/evaporation technique. The processing parameters were optimized in order to provide an average microparticle size of about 60 μm, allowing for incorporation inside the macropores (100 μm) of the hydroxyapatite scaffold. Gentamicin-loaded PLGA microparticles showed a sustained release for 25–30 days and a rapid antibacterial activity due to a burst effect, the extent of which was controlled by the initial loading of the microparticles. SEM pictures revealed a highly porous microparticle structure, which can help to reduce the micro environmental pH drop and autocatalytic effects. The biological evaluation showed the cytocompatibility and non-hemolytic property of the microparticles, and the antibacterial activity against Staphylococcus aureus under the given conditions. - Highlights: • The optimization of microparticle preparation parameters allows to obtain a size compatible with the bone substitute porosity • PDL% has a direct impact on the burst effect, a control release of gentamicin was obtained • The incorporation of microparticles into the

  10. Effects of gentamicin on the recovery of renal function after unilateral hydronephrosis

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Nobumitsu [Ehime Univ., Shigenobu (Japan). School of Medicine

    2002-06-01

    Urinary tract infection is one of complications in hydronephrosis, and antibiotics such as gentamicin are indicated for the treatment. However, gentamicin is known to cause drug-induced nephropathy. Using a rat kidney model, we investigated the effects of gentamicin treatment on the functional recovery from unilateral hydronephrosis. Quantitative separate renal function study by means of Technetium-99m DMSA renoscintigraphy revealed that contralateral kidney was affected by the treatment right after the release of complete ureteral obstruction. Moreover, in the case of incomplete ureteral obstruction, bilateral kidneys were affected by the treatment. Morphological studies using in situ DNA3' -end labeling and immunohistochemical methods showed that regeneration in the bilateral kidney followed gentamicin treatment right after the release. These results suggest that we should take account of separate renal function failure after gentamicin administration in the perihydronephrotic periods. (author)

  11. Cost evaluation of therapeutic drug monitoring of gentamicin at a teaching hospital in Malaysia

    Directory of Open Access Journals (Sweden)

    Ibrahim MI

    2014-03-01

    Full Text Available Background: Therapeutic drug monitoring (TDM makes use of serum drug concentrations as an adjunct to decision-making. Preliminary data in our hospital showed that approximately one-fifth of all drugs monitored by TDM service were gentamicin. Objective: In this study, we evaluated the costs associated with providing the service in patients with bronchopneumonia and treated with gentamicin. Methods: We retrospectively collected data from medical records of patients admitted to the Hospital Universiti Sains Malaysia over a 5-year period. These patients were diagnosed with bronchopneumonia and were on gentamicin as part of their treatment. Five hospitalisation costs were calculated; (i cost of laboratory and clinical investigations, (ii cost associated with each gentamicin dose, (iii fixed and operating costs of TDM service, (iv cost of providing medical care, and (v cost of hospital stay during gentamicin treatment. Results: There were 1920 patients admitted with bronchopneumonia of which 67 (3.5% had TDM service for gentamicin. Seventy-three percent (49/67 patients were eligible for final analysis. The duration of gentamicin therapy ranged from 3 to 15 days. The cost of providing one gentamicin assay was MYR25, and the average cost of TDM service for each patient was MYR104. The average total hospitalisation cost during gentamicin treatment for each patient was MYR442 (1EUR approx. MYR4.02. Conclusion: Based on the hospital perspective, in patients with bronchopneumonia and treated with gentamicin, the provision of TDM service contributes to less than 25% of the total cost of hospitalization.

  12. Severity of gentamicin's nephrotoxic effect on patients with infective endocarditis: a prospective observational cohort study of 373 patients

    DEFF Research Database (Denmark)

    Buchholtz, Kristine; Larsen, Carsten T; Hassager, Christian

    2009-01-01

    BACKGROUND: Gentamicin is often used to treat infective endocarditis (IE). Gentamicin is highly effective, but its applicability is reduced by its nephrotoxic effect. The aim of this study was to quantify the nephrotoxic effect of gentamicin and the association between the nephrotoxic effect...

  13. Effect of normobaric hyperoxia on gentamicin-induced nephrotoxicity in rats

    Directory of Open Access Journals (Sweden)

    Majid Tavafi

    2014-04-01

    Full Text Available Objective(s:Gentamicin sulphate (GS nephrotoxicity seems to be related to the generation of reactive oxygen species. There is evidence that oxygen preconditioning increases the activity of antioxidant enzymes. Materials and Methods: Forty eight female rats were divided into 6 groups (n=8 as follows: group 1 was the control, group 2 received daily GS, groups 3,4 and 5 received oxygen 2 hr/day for 2 days, 4 hr/day for 2 days, 4 hr/day for 4 days, recpectively and then received daily GS, group 6 received oxygen 2 hr/day for 2 days and then received 2 hr oxygen before daily GS injection. Oxygen (with 90% purity used at the flow rate of 4 l/min. GS administred for 8 days (100 mg/kg, IP. Tissue sections prepared from the left kidney, stained with PAS method and then studied hisopathologically and stereologically. The right kidneys were homogenized and the supernatants were prepared. Serum MDA, creatinine and urea, renal  MDA, gluthatione and catalase activity were measured. The data were analyzed by Mann-Whitney U test at the significant level of PResults: Oxygen therapy significantly improves serum creatinine and urea, preserve tubular volume density, reduce tubular necrosis in groups 4 and 6 compared to group 2. Oxygen therapy significantly increases renal catalase in groups 4 and 6 compared to group 2.   Conclusion: Pretreatment with normobaric hyperoxia and daily oxygen therapy improved gentamicin nephrotoxicity possibly via inhibition of lipid peroxidation and increasing the renal catalase activity but could not restore any parameter at the same levels as control group.

  14. Polymers as Carriers of Gentamicin in Traumatology and Orthopedic Surgery - Current State Of Knowledge.

    Science.gov (United States)

    Witkowski, Jarosław; Wnukiewicz, Witold; Reichert, Paweł

    2016-01-01

    Osteomyelitis in patients undergoing surgery because of injuries and diseases of the musculoskeletal system is a serious clinical, economic and social problem. It is one of the greatest therapeutic challenges in traumatology and orthopedic surgery. To achieve the best results in the treatment of osteomyelitis, surgical debridement and intravenous antibiotic therapy is supported by local antibiotic delivery. Many different substances can be used as drug carriers. In this study we present and compare some polymers used as carriers of gentamicin. Some of them, such as poly(methyl methacrylate), are well known and have been used for 30 years, and others, such as polycaprolactone, polyacrylic acid, polyanhydrides, poly-trimethylene carbonate, polylactide, polyglycolide and poly(trimethylene carbonate), are perspectives for the future. In this study, we have tried to briefly present all of these polymers and compare some of their features. We have concentrated on the pharmacokinetics and bioactivity of such implants, which are important aspects for their potential practical use.

  15. Liquid low level waste management expert system

    International Nuclear Information System (INIS)

    Ferrada, J.J.; Abraham, T.J.; Jackson, J.R.

    1991-01-01

    An expert system has been developed as part of a new initiative for the Oak Ridge National Laboratory (ORNL) systems analysis program. This expert system will aid in prioritizing radioactive waste streams for treatment and disposal by evaluating the severity and treatability of the problem, as well as the final waste form. The objectives of the expert system development included: (1) collecting information on process treatment technologies for liquid low-level waste (LLLW) that can be incorporated in the knowledge base of the expert system, and (2) producing a prototype that suggests processes and disposal technologies for the ORNL LLLW system. 4 refs., 9 figs

  16. Features, Events, and Processes: system Level

    Energy Technology Data Exchange (ETDEWEB)

    D. McGregor

    2004-10-15

    The purpose of this analysis report is to evaluate and document the inclusion or exclusion of the system-level features, events, and processes (FEPs) with respect to modeling used to support the total system performance assessment for the license application (TSPA-LA). A screening decision, either Included or Excluded, is given for each FEP along with the technical basis for screening decisions. This information is required by the U.S. Nuclear Regulatory Commission (NRC) at 10 CFR 63.113 (d, e, and f) (DIRS 156605). The system-level FEPs addressed in this report typically are overarching in nature, rather than being focused on a particular process or subsystem. As a result, they are best dealt with at the system level rather than addressed within supporting process-level or subsystem-level analyses and models reports. The system-level FEPs also tend to be directly addressed by regulations, guidance documents, or assumptions listed in the regulations; or are addressed in background information used in development of the regulations. For included FEPs, this analysis summarizes the implementation of the FEP in the TSPA-LA (i.e., how the FEP is included). For excluded FEPs, this analysis provides the technical basis for exclusion from the TSPA-LA (i.e., why the FEP is excluded). The initial version of this report (Revision 00) was developed to support the total system performance assessment for site recommendation (TSPA-SR). This revision addresses the license application (LA) FEP List (DIRS 170760).

  17. Features, Events, and Processes: system Level

    International Nuclear Information System (INIS)

    D. McGregor

    2004-01-01

    The purpose of this analysis report is to evaluate and document the inclusion or exclusion of the system-level features, events, and processes (FEPs) with respect to modeling used to support the total system performance assessment for the license application (TSPA-LA). A screening decision, either Included or Excluded, is given for each FEP along with the technical basis for screening decisions. This information is required by the U.S. Nuclear Regulatory Commission (NRC) at 10 CFR 63.113 (d, e, and f) (DIRS 156605). The system-level FEPs addressed in this report typically are overarching in nature, rather than being focused on a particular process or subsystem. As a result, they are best dealt with at the system level rather than addressed within supporting process-level or subsystem-level analyses and models reports. The system-level FEPs also tend to be directly addressed by regulations, guidance documents, or assumptions listed in the regulations; or are addressed in background information used in development of the regulations. For included FEPs, this analysis summarizes the implementation of the FEP in the TSPA-LA (i.e., how the FEP is included). For excluded FEPs, this analysis provides the technical basis for exclusion from the TSPA-LA (i.e., why the FEP is excluded). The initial version of this report (Revision 00) was developed to support the total system performance assessment for site recommendation (TSPA-SR). This revision addresses the license application (LA) FEP List (DIRS 170760)

  18. Liquid level control system for vapour generator

    International Nuclear Information System (INIS)

    Singh, G.

    1984-01-01

    A system for regulating the liquid level in a vapor generator, in which the incoming flow of feed liquid is regulated in response to the difference between the measured liquid level and a reference level, the difference between the exiting vapor mass flow rate and the incoming liquid mass flow rate, and a function of the measured incoming liquid temperature. The temperature function produces a gain value, which increases in response to decreasing incoming liquid temperature. The purpose of the temperature function is to stabilize the level control under transient conditions (e.g. sudden lose of load). (author)

  19. Effects of neuroactive steroids on cochlear hair cell death induced by gentamicin.

    Science.gov (United States)

    Nakamagoe, Mariko; Tabuchi, Keiji; Nishimura, Bungo; Hara, Akira

    2011-12-11

    As neuroactive steroids, sex steroid hormones have non-reproductive effects. We previously reported that 17β-estradiol (βE2) had protective effects against gentamicin (GM) ototoxicity in the cochlea. In the present study, we examined whether the protective action of βE2 on GM ototoxicity is mediated by the estrogen receptor (ER) and whether other estrogens (17α-estradiol (αE2), estrone (E1), and estriol (E3)) and other neuroactive steroids, dehydroepiandrosterone (DHEA) and progesterone (P), have similar protective effects. The basal turn of the organ of Corti was dissected from Sprague-Dawley rats and cultured in a medium containing 100 μM GM for 48h. The effects of βE2 and ICI 182,780, a selective ER antagonist, were examined. In addition, the effects of other estrogens, DHEA and P were tested using this culture system. Loss of outer hair cells induced by GM exposure was compared among groups. βE2 exhibited a protective effect against GM ototoxicity, but its protective effect was antagonized by ICI 182,780. αE2, E1, and E3 also protected hair cells against gentamicin ototoxicity. DHEA showed a protective effect; however, the addition of ICI 182,780 did not affect hair cell loss. P did not have any effect on GM-induced outer hair cell death. The present findings suggest that estrogens and DHEA are protective agents against GM ototoxicity. The results of the ER antagonist study also suggest that the protective action of βE2 is mediated via ER but that of DHEA is not related to its conversion to estrogen and binding to ER. Further studies on neuroactive steroids may lead to new insights regarding cochlear protection. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Control of System with Defined Risk Level

    Directory of Open Access Journals (Sweden)

    Pavol Tomasov

    2002-01-01

    Full Text Available In the following paper the basic requirements for system control with defined risk level is presented. The paper should be an introduction to describe of theoretical apparatus, which was created during some years of research work in the Department of information and safety systems in this area. It a modification or creation of new parts of Information theory, System theory, and Control theory means. This parts are necessary for the analysis and synthesis tasks in the systems where dominant attribute of control is defined risk level. The basic problem is the creation of protect mechanism again the threats from inside and from controlled system environs. For each risk reduction mechanism is needed some redundancy which should be into control algorithm to put by exactly determined way.

  1. Development of digital low level rf system

    International Nuclear Information System (INIS)

    Michizono, Shinichiro; Anami, Shozo; Katagiri, Hiroaki; Fang, Zhigao; Matsumoto, Toshihiro; Miura, Takako; Yano, Yoshiharu; Yamaguchi, Seiya; Kobayashi, Tetsuya

    2008-01-01

    One of the biggest advantages of the digital low level rf (LLRF) system is its flexibility. Owing to the recent rapid progress in digital devices (such as ADCs and DACs) and telecommunication devices (mixers and IQ modulators), digital LLRF system becomes popular in these 10 years. The J-PARC linac LLRF system adopted cPCI crates and FPGA based digital feedback system. Since the LLRF control of the normal conducting cavities are more difficult than super conducting cavities due to its lower Q values, fast processing using the FPGA was the essential to the feedback control. After the successful operation of J-PARC linac LLRF system, we developed the STF (ILC test facility in KEK) LLRF system. Since the klystron drives eight cavities in STF phase 1, we modified the FPGA board. Basic configuration and the performances of these systems are summarized. The future R and D projects (ILC and ERL) is also described from the viewpoints of LLRF. (author)

  2. Packaged low-level waste verification system

    International Nuclear Information System (INIS)

    Tuite, K.T.; Winberg, M.; Flores, A.Y.; Killian, E.W.; McIsaac, C.V.

    1996-01-01

    Currently, states and low-level radioactive waste (LLW) disposal site operators have no method of independently verifying the radionuclide content of packaged LLW that arrive at disposal sites for disposal. At this time, disposal sites rely on LLW generator shipping manifests and accompanying records to insure that LLW received meets the waste acceptance criteria. An independent verification system would provide a method of checking generator LLW characterization methods and help ensure that LLW disposed of at disposal facilities meets requirements. The Mobile Low-Level Waste Verification System (MLLWVS) provides the equipment, software, and methods to enable the independent verification of LLW shipping records to insure that disposal site waste acceptance criteria are being met. The MLLWVS system was developed under a cost share subcontract between WMG, Inc., and Lockheed Martin Idaho Technologies through the Department of Energy's National Low-Level Waste Management Program at the Idaho National Engineering Laboratory (INEL)

  3. Load leveling on industrial refrigeration systems

    Science.gov (United States)

    Bierenbaum, H. S.; Kraus, A. D.

    1982-01-01

    A computer model was constructed of a brewery with a 2000 horsepower compressor/refrigeration system. The various conservation and load management options were simulated using the validated model. The savings available for implementing the most promising options were verified by trials in the brewery. Result show that an optimized methodology for implementing load leveling and energy conservation consisted of: (1) adjusting (or tuning) refrigeration systems controller variables to minimize unnecessary compressor starts, (2) The primary refrigeration system operating parameters, compressor suction pressure, and discharge pressure are carefully controlled (modulated) to satisfy product quality constraints (as well as in-process material cooling rates and temperature levels) and energy evaluating the energy cost savings associated with reject heat recovery, and (4) a decision is made to implement the reject heat recovery system based on a cost/benefits analysis.

  4. Modelling of Signal - Level Crossing System

    Directory of Open Access Journals (Sweden)

    Daniel Novak

    2006-01-01

    Full Text Available The author presents an object-oriented model of a railway level-crossing system created for the purpose of functional requirements specification. Unified Modelling Language (UML, version 1.4, which enables specification, visualisation, construction and documentation of software system artefacts, was used. The main attention was paid to analysis and design phases. The former phase resulted in creation of use case diagrams and sequential diagrams, the latter in creation of class/object diagrams and statechart diagrams.

  5. Actively shielded low level gamma - spectrometric system

    International Nuclear Information System (INIS)

    Mrdja, D.; Bikit, I.; Forkapic, S.; Slivka, J.; Veskovic, M.

    2005-01-01

    The results of the adjusting and testing of the actively shielded low level gamma-spectrometry system are presented. The veto action of the shield reduces the background in the energy region of 50 keV to the 2800 keV for about 3 times. (author) [sr

  6. System level modelling with open source tools

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Koefoed; Madsen, Jan; Niaki, Seyed Hosein Attarzadeh

    , called ForSyDe. ForSyDe is available under the open Source approach, which allows small and medium enterprises (SME) to get easy access to advanced modeling capabilities and tools. We give an introduction to the design methodology through the system level modeling of a simple industrial use case, and we...

  7. Gentamicin modified chitosan film with improved antibacterial property and cell biocompatibility.

    Science.gov (United States)

    Liu, Yang; Ji, Peihong; Lv, Huilin; Qin, Yong; Deng, Linhong

    2017-05-01

    Gentamicin modified chitosan film (CS-GT) was produced using a three-step procedure comprising: (i) the chitosan solution was air-dried to form a chitosan (CS) film, (ii) using citric acid to generate the amide and carboxyl groups on the surface of CS, (iii) the CS with surface carboxyl groups was modified by grafting of gentamicin. After modification, this CS-GT film has excellent hydrophilicity and biocompatibility. It is very evident that the gentamicin grafting treatment significantly improves the antibacterial properties of the CS film. Our preliminary results suggest that this novel gentamicin modified chitosan film, which can be prepared in large quantities and at low cost, should have potential application in biomedical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. TAXATION SYSTEM AT INTRA PRODUCTION LEVEL

    Directory of Open Access Journals (Sweden)

    L. I. Podderegina

    2006-01-01

    Full Text Available The paper presents results of the analysis concerning taxation in the country at the level of an enteфrise and its structural sub-divisions in the period of transforming economy.Recommendations are given on the following aspects: modernization of income taxation system for natural persons; tax payment in case of wage computation; exclusion of tax payments and assignments fi-om production cost value which are not connected with the production process; tax computation for real property; evaluation of enterprise taxation level.The paper shows the possible cases concerning formation of tax payments and assignments of an enterprise and its structural sub-divisions.Taxation system is shown at the level of enterprise structural sub-divisions (shop, department, at the level of shop structural sub-divisions (section, team, for works to be executed by an individual person of the production process (operation, product, works, services. This system promotes to efficient functioning of intra-production economical relations.The paper provides possible variants of formation of taxation payments and assignments for an enterprise and its structural sub-divisions.

  9. Characterisation, in vitro release study, and antibacterial activity of montmorillonite-gentamicin complex material

    International Nuclear Information System (INIS)

    Rapacz-Kmita, A.; Bućko, M.M.; Stodolak-Zych, E.; Mikołajczyk, M.; Dudek, P.; nd Department of Surgery, Kopernika 21, 31-501 Krakow (Poland))" data-affiliation=" (Jagiellonian University, Medical College, 2nd Department of Surgery, Kopernika 21, 31-501 Krakow (Poland))" >Trybus, M.

    2017-01-01

    The present paper concerns the potential use of montmorillonite as a drug carrier and focusses on the intercalation of the studied clay with gentamicin (an aminoglycoside antibiotic) at various temperatures (20, 50 and 80 °C). The experiments were performed to identify the temperature required for the optimum intercalation of gentamicin into the interlayer of montmorillonite. The structural and microstructural properties of gentamicin and the potential for introducing it between smectite clay layers were investigated by means of X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopic techniques, and SEM with EDS analysis. Additionally, the in vitro drug release behaviour of the montmorillonite-gentamicin complex and its antibacterial activity against Escherichia coli (E. coli) bacteria was investigated. Based on these studies, the impact of temperature on the intercalation of the drug between layers of smectite was evaluated. It was found that an intercalation temperature of 50 °C resulted in the highest shift in the position of principle peak d (001) as measured by XRD, suggesting, that the greatest amount of gentamicin had been introduced into the interlayer space of montmorillonite at this temperature. Subsequently, the montmorillonite-gentamicin complex material obtained at 50 °C revealed the greatest capacity for killing E. coli bacteria during an in vitro test. - Highlights: • A novel montmorillonite-gentamicin hybrid materials was prepared as potential drug carrier. • Optimal conditions for the intercalation of gentamicin into the interlayer space of montmorillonite were tested. • The MMT-G complex material obtained at 50 °C revealed the greatest capacity for killing E. coli during the inhibitory zone test. • Modulating drug delivery was monitored and confirmed in in vitro drug release study.

  10. Effect of cyclooxygenase inhibitors on gentamicin-induced nephrotoxicity in rats

    Directory of Open Access Journals (Sweden)

    Hosaka E.M.

    2004-01-01

    Full Text Available The frequent use of nonsteroidal anti-inflammatory drugs (NSAID in combination with gentamicin poses the additional risk of nephrotoxic renal failure. Cyclooxygenase-1 (COX-1 is the main enzyme responsible for the synthesis of renal vasodilator prostaglandins, while COX-2 participates predominantly in the inflammatory process. Both are inhibited by non-selective NSAID such as indomethacin. Selective COX-2 inhibitors such as rofecoxib seem to have fewer renal side effects than non-selective inhibitors. The objective of the present study was to determine whether the combined use of rofecoxib and gentamicin can prevent the increased renal injury caused by gentamicin and indomethacin. Male Wistar rats (250-300 g were treated with gentamicin (100 mg/kg body weight, ip, N = 7, indomethacin (5 mg/kg, orally, N = 7, rofecoxib (1.4 mg/kg, orally, N = 7, gentamicin + rofecoxib (100 and 1.4 mg/kg, respectively or gentamicin + indomethacin (100 and 5 mg/kg, respectively, N = 8 for 5 days. Creatinine clearance and alpha-glutathione-S-transferase concentrations were used as markers of renal injury. Animals were anesthetized with ether and sacrificed for blood collection. The use of gentamicin plus indomethacin led to worsened renal function (0.199 ± 0.019 ml/min, as opposed to the absence of a nephrotoxic effect of rofecoxib when gentamicin plus rofexicob was used (0.242 ± 0.011 ml/min. These results indicate that COX-2-selective inhibitors can be used as an alternative treatment to conventional NSAID, especially in situations in which risk factors for nephrotoxicity are present.

  11. Characterisation, in vitro release study, and antibacterial activity of montmorillonite-gentamicin complex material

    Energy Technology Data Exchange (ETDEWEB)

    Rapacz-Kmita, A., E-mail: kmita@agh.edu.pl [AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Mickiewicza 30, 30-059 Krakow (Poland); Bućko, M.M.; Stodolak-Zych, E. [AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Mickiewicza 30, 30-059 Krakow (Poland); Mikołajczyk, M. [The University Hospital in Krakow, Division of Microbiology, Kopernika 19, 31-501 Krakow (Poland); Dudek, P. [AGH University of Science and Technology, Faculty of Mechanical Engineering and Robotics, Mickiewicza 30, 30-059 Krakow (Poland); Trybus, M. [Jagiellonian University, Medical College, 2" n" d Department of Surgery, Kopernika 21, 31-501 Krakow (Poland)

    2017-01-01

    The present paper concerns the potential use of montmorillonite as a drug carrier and focusses on the intercalation of the studied clay with gentamicin (an aminoglycoside antibiotic) at various temperatures (20, 50 and 80 °C). The experiments were performed to identify the temperature required for the optimum intercalation of gentamicin into the interlayer of montmorillonite. The structural and microstructural properties of gentamicin and the potential for introducing it between smectite clay layers were investigated by means of X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopic techniques, and SEM with EDS analysis. Additionally, the in vitro drug release behaviour of the montmorillonite-gentamicin complex and its antibacterial activity against Escherichia coli (E. coli) bacteria was investigated. Based on these studies, the impact of temperature on the intercalation of the drug between layers of smectite was evaluated. It was found that an intercalation temperature of 50 °C resulted in the highest shift in the position of principle peak d{sub (001)} as measured by XRD, suggesting, that the greatest amount of gentamicin had been introduced into the interlayer space of montmorillonite at this temperature. Subsequently, the montmorillonite-gentamicin complex material obtained at 50 °C revealed the greatest capacity for killing E. coli bacteria during an in vitro test. - Highlights: • A novel montmorillonite-gentamicin hybrid materials was prepared as potential drug carrier. • Optimal conditions for the intercalation of gentamicin into the interlayer space of montmorillonite were tested. • The MMT-G complex material obtained at 50 °C revealed the greatest capacity for killing E. coli during the inhibitory zone test. • Modulating drug delivery was monitored and confirmed in in vitro drug release study.

  12. Effect of cyclooxygenase inhibitors on gentamicin-induced nephrotoxicity in rats.

    Science.gov (United States)

    Hosaka, E M; Santos, O F P; Seguro, A C; Vattimo, M F F

    2004-07-01

    The frequent use of nonsteroidal anti-inflammatory drugs (NSAID) in combination with gentamicin poses the additional risk of nephrotoxic renal failure. Cyclooxygenase-1 (COX-1) is the main enzyme responsible for the synthesis of renal vasodilator prostaglandins, while COX-2 participates predominantly in the inflammatory process. Both are inhibited by non-selective NSAID such as indomethacin. Selective COX-2 inhibitors such as rofecoxib seem to have fewer renal side effects than non-selective inhibitors. The objective of the present study was to determine whether the combined use of rofecoxib and gentamicin can prevent the increased renal injury caused by gentamicin and indomethacin. Male Wistar rats (250-300 g) were treated with gentamicin (100 mg/kg body weight, ip, N = 7), indomethacin (5 mg/kg, orally, N = 7), rofecoxib (1.4 mg/kg, orally, N = 7), gentamicin + rofecoxib (100 and 1.4 mg/kg, respectively) or gentamicin + indomethacin (100 and 5 mg/kg, respectively, N = 8) for 5 days. Creatinine clearance and alpha-glutathione-S-transferase concentrations were used as markers of renal injury. Animals were anesthetized with ether and sacrificed for blood collection. The use of gentamicin plus indomethacin led to worsened renal function (0.199 +/- 0.019 ml/min), as opposed to the absence of a nephrotoxic effect of rofecoxib when gentamicin plus rofexicob was used (0.242 +/- 0.011 ml/min). These results indicate that COX-2-selective inhibitors can be used as an alternative treatment to conventional NSAID, especially in situations in which risk factors for nephrotoxicity are present.

  13. EFFICACY OF GENTAMICIN AFTER INTRAYOLK ADMINISTRATION IN EXPERIMENT ALLY INDUCED OMPHALITIS IN BROILER CHICKS

    Directory of Open Access Journals (Sweden)

    Muhammad Ashraf, Qamar Arif and Kashif Aziz Khan1

    2002-04-01

    Full Text Available A study was conducted to observe the effect of intrayolk injection of gentamicin on experimentally induced omphalitis in broiler chicks. Escherichia coli was injected into yolk sac to induce omphalitis and treatment was done by intrayolk injection of gentamicin. Results showed that mortality decreased and feed intake increased after treatment, Intrayolk injection of antibiotics is suggested as an alternative to oral administration for the treatment of omphalitis in chicks.

  14. Alternating Mupirocin/Gentamicin is Associated with Increased Risk of Fungal Peritonitis as Compared with Gentamicin Alone - Results of a Randomized Open-Label Controlled Trial.

    Science.gov (United States)

    Wong, Ping-Nam; Tong, Gensy M W; Wong, Yuk-Yi; Lo, Kin-Yee; Chan, Shuk-Fan; Lo, Man-Wai; Lo, Kwok-Chi; Ho, Lo-Yi; Tse, Cindy W S; Mak, Siu-Ka; Wong, Andrew K M

    2016-01-01

    ♦ Catheter-related infection, namely exit-site infection (ESI) and peritonitis, is a major infectious complication and remains a main cause of technique failure for patients receiving peritoneal dialysis (PD). Topical application of antibiotic cream might reduce catheter-related infection but emergence of resistant or opportunistic organisms could be a concern. Optimal topical agents and regimens remain to be determined. We did a study to examine the effect of an alternating topical antibiotic regimen in preventing catheter-related infection. ♦ We performed a single-center, randomized, open-label study to compare daily topical application of gentamicin cream with a gentamicin/mupirocin alternate regimen to the exit site. Patients randomized to alternating regimen were asked to have daily application of gentamicin cream in odd months and mupirocin cream in even months. Primary outcomes were ESI and peritonitis. Secondary outcomes were catheter removal or death caused by catheter-related infection. A total of 146 patients (71, gentamicin group; 75, alternating regimen group) were enrolled with a total follow-up duration of 174 and 181 patient-years for gentamicin and alternating groups, respectively. All patients were followed up until catheter removal, death, transfer to another unit, transplantation or the end of the study on March 31, 2014. There were no significant differences in the age, sex, dialysis vintage, and rate of diabetes, helper-assisted dialysis and methicillin-resistant Staphylococcus aureus (MRSA) carriage state. ♦ No difference was seen in the time to first ESI or peritonitis. However, the time to first gram-negative peritonitis seemed longer for the gentamicin group (p = 0.055). The 2 groups showed a similar rate of ESI (0.17/yr vs 0.19/yr, p = 0.93) but P. aeruginosa ESI was less common in the gentamicin group (0.06/yr vs 0.11/yr, p Peritonitis rate was significantly lower in the gentamicin group (0.22/yr vs 0.32/yr, p peritonitis (0.08/yr

  15. National high-level waste systems analysis

    International Nuclear Information System (INIS)

    Kristofferson, K.; O'Holleran, T.P.

    1996-01-01

    Previously, no mechanism existed that provided a systematic, interrelated view or national perspective of all high-level waste treatment and storage systems that the US Department of Energy manages. The impacts of budgetary constraints and repository availability on storage and treatment must be assessed against existing and pending negotiated milestones for their impact on the overall HLW system. This assessment can give DOE a complex-wide view of the availability of waste treatment and help project the time required to prepare HLW for disposal. Facilities, throughputs, schedules, and milestones were modeled to ascertain the treatment and storage systems resource requirements at the Hanford Site, Savannah River Site, Idaho National Engineering Laboratory, and West Valley Demonstration Project. The impacts of various treatment system availabilities on schedule and throughput were compared to repository readiness to determine the prudent application of resources. To assess the various impacts, the model was exercised against a number of plausible scenarios as discussed in this paper

  16. Comparison of E-test with other conventional susceptibility testing methods for ciprofloxacin and gentamicin against gram negative enteric bacilli.

    Science.gov (United States)

    Ogbolu, D O; Terry-Alli, O A; Daini, O A; Olabiyi, F A; Igharo, E A

    2012-06-01

    Increasing antibiotic resistance in Gram negative bacteria has led to the need for a faster and reliable method for determining antimicrobial susceptibility testing. In a resource poor setting like ours, it's also important to look for methods that will be clinically and economically beneficial to the patient. This study was aimed at evaluating the Epsilometer test (E-test) and conventional methods for determining antimicrobial susceptibility of isolates of Gram-negative enteric bacteria to ciprofloxacin and gentamicin. Disc diffusion, E-test, broth dilution and agar dilution methods were performed on 54 bacterial isolates. Using the E-test, 88.9% of bacterial isolates were resistant to ciprofloxacin, 92.6% were resistant using broth microdilution, 96.3% were resistant using agar dilution and 72.2% were resistant using disc diffusion. Minimum inhibitory concentration (MIC50) of isolates for gentamicin showed significant difference for all the techniques (p 0.05). Both E-test and broth dilution methods showed high levels of agreement (p > 0.05), there were low levels of agreement between E-test and agar dilution method (p < 0.05), especially at MIC50. The E-test can therefore be considered a reliable method to determine antimicrobial susceptibility testing and it gives results which are at least as accurate as those obtained by the broth dilution method.

  17. Level controlling system in BWR type reactors

    International Nuclear Information System (INIS)

    Joge, Toshio; Higashigawa, Yuichi; Oomori, Takashi.

    1981-01-01

    Purpose: To reasonably attain fully automatic water level control in the core of BWR type nuclear power plants. Constitution: A feedwater flow regulation valve for reactor operation and a feedwater flow regulation valve for starting are provided at the outlet of a motor-driven feedwater pump in a feedwater system, and these valves are controlled by a feedwater flow rate controller. While on the other hand, a damp valve for reactor clean up system is controlled either in ''computer'' mode or in ''manual'' mode selected by a master switch, that is, controlled from a computer or the ON-OFF switch of the master switch by way of a valve control analog memory and a turn-over switch. In this way, the water level in the nuclear reactor can be controlled in a fully automatic manner reasonably at the starting up and shutdown of the plant to thereby provide man power saving. (Seki, T.)

  18. The CMS High Level Trigger System

    CERN Document Server

    Afaq, A; Bauer, G; Biery, K; Boyer, V; Branson, J; Brett, A; Cano, E; Carboni, A; Cheung, H; Ciganek, M; Cittolin, S; Dagenhart, W; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutiérrez-Mlot, E; Gutleber, J; Jacobs, C; Kim, J C; Klute, M; Kowalkowski, J; Lipeles, E; Lopez-Perez, Juan Antonio; Maron, G; Meijers, F; Meschi, E; Moser, R; Murray, S; Oh, A; Orsini, L; Paus, C; Petrucci, A; Pieri, M; Pollet, L; Rácz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Sexton-Kennedy, E; Sumorok, K; Suzuki, I; Tsirigkas, D; Varela, J

    2007-01-01

    The CMS Data Acquisition (DAQ) System relies on a purely software driven High Level Trigger (HLT) to reduce the full Level-1 accept rate of 100 kHz to approximately 100 Hz for archiving and later offline analysis. The HLT operates on the full information of events assembled by an event builder collecting detector data from the CMS front-end systems. The HLT software consists of a sequence of reconstruction and filtering modules executed on a farm of O(1000) CPUs built from commodity hardware. This paper presents the architecture of the CMS HLT, which integrates the CMS reconstruction framework in the online environment. The mechanisms to configure, control, and monitor the Filter Farm and the procedures to validate the filtering code within the DAQ environment are described.

  19. Gentamicin coated iron oxide nanoparticles as novel antibacterial agents

    Science.gov (United States)

    Bhattacharya, Proma; Neogi, Sudarsan

    2017-09-01

    Applications of different types of magnetic nanoparticles for biomedical purposes started a long time back. The concept of surface functionalization of the iron oxide nanoparticles with antibiotics is a novel technique which paves the path for further application of these nanoparticles by virtue of their property of superparamagnetism. In this paper, we have synthesized novel iron oxide nanoparticles surface functionalized with Gentamicin. The average size of the particles, concluded from the HR-TEM images, came to be around 14 nm and 10 nm for unmodified and modified nanoparticles, respectively. The magnetization curve M(H) obtained for these nanoparticles are typical of superparamagnetic nature and having almost zero values of coercivity and remanance. The release properties of the drug coated nanoparticles were studied; obtaining an S shaped profile, indicating the initial burst effect followed by gradual sustained release. In vitro investigations against various gram positive and gram negative strains viz Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa and Bacillus subtilis indicated significant antibacterial efficiency of the drug-nanoparticle conjugate. The MIC values indicated that a small amount like 0.2 mg ml-1 of drug capped particles induce about 98% bacterial death. The novelty of the work lies in the drug capping of the nanoparticles, which retains the superparamagnetic nature of the iron oxide nanoparticles and the medical properties of the drug simultaneously, which is found to extremely blood compatible.

  20. Gentamicin-Containing Peptone-Yeast Extract Medium for Cocultivation of Hartmannella vermiformis ATCC 50256 and Virulent Strains of Legionella pneumophila.

    Science.gov (United States)

    Wadowsky, R M; Wang, L; Laus, S; Dowling, J N; Kuchta, J M; States, S J; Yee, R B

    1995-12-01

    We evaluated the use of peptone-yeast extract (PY) medium, different strains of Hartmannella vermiformis, and gentamicin in a coculture system to improve the discrimination of virulent and avirulent strains of Legionella pneumophila. H. vermiformis ATCC 50256 was unique among four strains of H. vermiformis, in that it multiplied equally well in Medium 1034 and PY medium (Medium 1034 without fetal calf serum, folic acid, hemin, and yeast nucleic acid and with a 50% reduction of peptone). However, both a virulent strain of L. pneumophila and its avirulent derivative strain multiplied in cocultures when PY medium was used. The multiplication of this avirulent strain was greatly reduced by incorporating gentamicin (1 (mu)g/ml) into the cocultivation system. Five virulent-avirulent sets of L. pneumophila strains were then tested for multiplication in cocultures with H. vermiformis ATCC 50256 and the gentamicin-containing PY medium. Only the virulent strains multiplied. The modified cocultivation system can discriminate between virulent and avirulent strains of L. pneumophila.

  1. JBP485 improves gentamicin-induced acute renal failure by regulating the expression and function of Oat1 and Oat3 in rats

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xinjin [Department of Clinical Pharmacology, College of Pharmacy, Dalian Medical University, Dalian (China); Meng, Qiang; Liu, Qi; Wang, Changyuan; Sun, Huijun; Peng, Jinyong; Ma, Xiaochi [Department of Clinical Pharmacology, College of Pharmacy, Dalian Medical University, Dalian (China); Provincial Key Laboratory for Pharmacokinetics and Transport, Dalian Medical University, Liaoning (China); Kaku, Taiichi [Japan Bioproducts Industry Co. Ltd., Tomigaya, Shibuya-ku, Tokyo (Japan); Liu, Kexin, E-mail: kexinliu@dlmedu.edu.cn [Department of Clinical Pharmacology, College of Pharmacy, Dalian Medical University, Dalian (China); Provincial Key Laboratory for Pharmacokinetics and Transport, Dalian Medical University, Liaoning (China)

    2013-09-01

    We investigated the effects of JBP485 (an anti-inflammatory dipeptide and a substrate of OAT) on regulation of the expression and function of renal Oat1 and Oat3, which can accelerate the excretion of accumulated uremic toxins (e.g. indoxyl sulfate) in the kidney to improve gentamicin-induced ARF in rats. JBP485 caused a significant decrease in the accumulation of endogenous substances (creatinine, blood urea nitrogen and indoxyl sulfate) in vivo, an increase in the excretion of exogenous compounds (lisinopril and inulin) into urine, and up-regulation of the expressions of renal Oat1 and Oat3 in the kidney tissues and slices via substrate induction. To determine the effect of JBP485 on the accelerated excretion of uremic toxins mediated by Oat1 and Oat3, the mRNA and protein expression levels of renal basolateral Oats were assessed by quantitative real-time PCR, western blot, immunohistochemical analysis and an immunofluorescence method. Gentamicin down-regulated the expression of Oats mRNA and protein in rat kidney, and these effects were reversed after administration of JBP485. In addition, JBP485 caused a significant decrease in MPO and MDA levels in the kidney, and improved the pathological condition of rat kidney. These results indicated that JBP485 improved acute renal failure by increasing the expression and function of Oat1 and Oat3, and by decreasing overoxidation of the kidney in gentamicin-induced ARF rats. - Highlights: • JBP485 could up-regulate function and expression of Oat1 and Oat3 in kidney. • Effects of JBP485 on ARF are mediated by stimulating excretion of uremic toxins. • JBP485 protected against gentamicin-induced ARF by decreasing MPO and MDA.

  2. Optimal maintenance policy incorporating system level and unit level for mechanical systems

    Science.gov (United States)

    Duan, Chaoqun; Deng, Chao; Wang, Bingran

    2018-04-01

    The study works on a multi-level maintenance policy combining system level and unit level under soft and hard failure modes. The system experiences system-level preventive maintenance (SLPM) when the conditional reliability of entire system exceeds SLPM threshold, and also undergoes a two-level maintenance for each single unit, which is initiated when a single unit exceeds its preventive maintenance (PM) threshold, and the other is performed simultaneously the moment when any unit is going for maintenance. The units experience both periodic inspections and aperiodic inspections provided by failures of hard-type units. To model the practical situations, two types of economic dependence have been taken into account, which are set-up cost dependence and maintenance expertise dependence due to the same technology and tool/equipment can be utilised. The optimisation problem is formulated and solved in a semi-Markov decision process framework. The objective is to find the optimal system-level threshold and unit-level thresholds by minimising the long-run expected average cost per unit time. A formula for the mean residual life is derived for the proposed multi-level maintenance policy. The method is illustrated by a real case study of feed subsystem from a boring machine, and a comparison with other policies demonstrates the effectiveness of our approach.

  3. Therapeutic efficacy of liposome-encapsulated gentamicin in rat Klebsiella pneumoniae pneumonia in relation to impaired host defense and low bacterial susceptibility to gentamicin.

    NARCIS (Netherlands)

    R.M. Schiffelers (Raymond); G. Storm (Gert); M.T. ten Kate (Marian); I.A.J.M. Bakker-Woudenberg (Irma)

    2001-01-01

    textabstractLong-circulating liposomes (LCL) may be used as targeted antimicrobial drug carriers as they localize at sites of infection. As a result, LCL-encapsulated gentamicin (LE-GEN) has demonstrated superior antibacterial activity over the free drug in a

  4. Activity of daptomycin alone and in combination with rifampin and gentamicin against Staphylococcus aureus assessed by time-kill methodology.

    Science.gov (United States)

    Credito, Kim; Lin, Gengrong; Appelbaum, Peter C

    2007-04-01

    The synergistic effects of daptomycin plus gentamicin or rifampin were tested against 50 Staphylococcus aureus strains, with daptomycin MICs ranging between 0.25 and 8 microg/ml. Daptomycin sub-MICs combined with gentamicin concentrations lower than the MIC yielded synergy in 34 (68%) of the 50 strains. Daptomycin combined with rifampin yielded synergy in one vancomycin-intermediate S. aureus strain only, and virtually all synergy occurred between daptomycin and gentamicin.

  5. Nephroprotective potential of artichoke leaves extract against gentamicin in rats: Antioxidant mechanisms.

    Science.gov (United States)

    Khattab, Hala Ah; Wazzan, Maha Am; Al-Ahdab, Maha A

    2016-09-01

    Nephrotoxicity represents a major health problem. This study aims to determine nephroprotective of artichoke leaves extract (ALE) against gentamicin (GM) injection in male rats. Rats (n=30) were divided into; negative control, nephrotoxic (GM) injected intraperitoneally (i.p.) with GM (100 mg/kg b.wt/d for 10 days), and groups administered orally with ALE (200, 400 or 600 mg/kg b.wt/d) and injected with GM. The results revealed that, GM injection induced marked nephrotoxicity as evidenced by significant increase in kidney functions, albumin and potassium (K+), with significant decrease in serum levels of total protein and sodium (Na + ) as compared with negative control group. There was significant increase in malondialdehyde (MDA) level in GM group compared with negative control group. Renal examined tissues showed severe changes manifested by atrophy of glomerular tuft, necrosis of epithelial lining renal tubules with apoptosis of tubular epithelium and renal hemorrhage. Simultaneous administration of ALE during GM therapy protected kidney tissues as evidenced by normalization of kidney biochemical parameters and minimized the histopathological changes. Therefore, ALE has nephroprotective and antioxidant effects, thus could be beneficial for kidney patients.

  6. In vitro synergy of baicalein and gentamicin against vancomycin-resistant Enterococcus.

    Science.gov (United States)

    Chang, Ping Chin; Li, Hua Yu; Tang, Hung Jen; Liu, Jien Wei; Wang, Jhi Joung; Chuang, Yin Ching

    2007-02-01

    Little is known about the possible synergism of baicalein, a bioactive flavone of Scutellariae radix (a Chinese herb), when used in conjunction with other antimicrobial agents against vancomycin-resistant Enterococcus (VRE). This in vitro study examined the possible synergism of the combination of baicalein and gentamicin against VRE. Minimal inhibitory concentrations (MICs) of baicalein as well as gentamicin were determined against 39 clinical isolates of VRE by the agar dilution method. Synergistic activities were determined using the checkerboard method based on the fractional inhibitory concentration indices and also the time-kill method. Further time-kill studies were conducted with these two agents against one randomly chosen clinical isolate, VRE-096. Minimal concentrations inhibiting 50% (MIC(50)) and 90% (MIC(90)) of isolates for baicalein and gentamicin were all >256 microg/mL. Synergism between baicalein and gentamicin was demonstrated against four clinical isolates of VRE (VRE-70, VRE-940, VRE-096 and VRE-721). When approximately 5 x 10(5) colony-forming units/mL of VRE-096 was incubated with both baicalein at a concentration of 32 microg/mL (1/8 x MIC) and gentamicin at a concentration of 128 microg/mL (1/2 x MIC), there was an inhibitory effect against VRE that persisted for 48 h. At 48 h, the combination of baicalein and gentamicin at these respective concentrations resulted in a reduction of growth by approximately 2 orders of magnitude compared to that for the starting inoculum and by 3 orders of magnitude compared to that for baicalein alone, the more active single agent. This study demonstrated that baicalein and gentamicin can act synergistically in inhibiting VRE in vitro.

  7. The second level trigger system of FAST

    CERN Document Server

    Martínez,G; Berdugo, J; Casaus, J; Casella, V; De Laere, D; Deiters, K; Dick, P; Kirkby, J; Malgeri, L; Mañá, C; Marín, J; Pohl, M; Petitjean, C; Sánchez, E; Willmott, C

    2009-01-01

    The Fibre Active Scintillator Target (FAST) experiment is a novel imaging particle detector currently operating in a high-intensity π+ beam at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The detector is designed to perform a high precision measurement of the μ+ lifetime, in order to determine the Fermi constant, Gf, to 1 ppm precision. A dedicated second level (LV2) hardware trigger system has been developed for the experiment. It performs an online analysis of the π/μ decay chain by identifying the stopping position of each beam particle and detecting the subsequent appearance of the muon. The LV2 trigger then records the muon stop pixel and selectively triggers the Time-to-Digital Converters (TDCs) in the vicinity. A detailed description of the trigger system is presented in this paper.

  8. The second level trigger system of FAST

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, G. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)], E-mail: gustavo.martinez@ciemat.es; Barcyzk, A. [CERN, CH-1211 Geneva 23 (Switzerland); Berdugo, J.; Casaus, J. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Casella, C.; De Laere, S. [Universite de Geneve, 30 quai Ernest-Anserment, CH-1211 Geneva 4 (Switzerland); Deiters, K.; Dick, P. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Kirkby, J.; Malgeri, L. [CERN, CH-1211 Geneva 23 (Switzerland); Mana, C.; Marin, J. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Pohl, M. [Universite de Geneve, 30 quai Ernest-Anserment, CH-1211 Geneva 4 (Switzerland); Petitjean, C. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Sanchez, E.; Willmott, C. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)

    2009-10-11

    The Fibre Active Scintillator Target (FAST) experiment is a novel imaging particle detector currently operating in a high-intensity {pi}{sup +} beam at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The detector is designed to perform a high precision measurement of the {mu}{sup +} lifetime, in order to determine the Fermi constant, G{sub f}, to 1 ppm precision. A dedicated second level (LV2) hardware trigger system has been developed for the experiment. It performs an online analysis of the {pi}/{mu} decay chain by identifying the stopping position of each beam particle and detecting the subsequent appearance of the muon. The LV2 trigger then records the muon stop pixel and selectively triggers the Time-to-Digital Converters (TDCs) in the vicinity. A detailed description of the trigger system is presented in this paper.

  9. System Level Analysis of LTE-Advanced

    DEFF Research Database (Denmark)

    Wang, Yuanye

    This PhD thesis focuses on system level analysis of Multi-Component Carrier (CC) management for Long Term Evolution (LTE)-Advanced. Cases where multiple CCs are aggregated to form a larger bandwidth are studied. The analysis is performed for both local area and wide area networks. In local area...... reduction. Compared to the case of reuse-1, they achieve a gain of 50∼500% in cell edge user throughput, with small or no loss in average cell throughput. For the wide area network, effort is devoted to the downlink of LTE-Advanced. Such a system is assumed to be backwards compatible to LTE release 8, i...... scheme is recommended. It reduces the CQI by 94% at low load, and 79∼93% at medium to high load, with reasonable loss in downlink performance. To reduce the ACK/NACK feedback, multiple ACK/NACKs can be bundled, with slightly degraded downlink throughput....

  10. [C1q/tumor necrosis factor related protein 6 (CTRP6) is involved in gentamicin-induced acute kidney injury in rats].

    Science.gov (United States)

    Li, Rong; Yang, Xiaoxia; Yu, Yan; Zhou, Meilan; Tian, Xiujuan; Feng, Shidong; Wang, Hanmin

    2016-11-01

    Objective To explore the role of the anti-inflammatory cytokine C1q/tumor necrosis factor related protein 6 (CTRP6) in gentamicin-induced acute kidney injury in rats. Methods SD rats were divided into 5 groups including control group, model group and the other 3 experimental groups. The rats in model group and experimental groups were subcutaneously injected with gentamicin at the dose of 400 mg/(kg.d) for consecutive 2 days to induce acute renal injury. Two days before gentamicin injection, the rats in the 3 experimental groups were given pAd-CTRP6 at the doses of 0.5, 5 and 50 mg/kg, respectively. The serum levels of blood urea nitrogen (BUN) and creatinine (Cr) were respectively assayed with picric acid colorimetry and ultraviolet spectrophotometry; ELISA was used to detect serum CTRP6 content and the production of interleukin 1β (IL-1β) and tumor necrosis factor α (TNF-α) in the kidney homogenate; Western blotting was performed to detect the expressions of CTRP6, caspase-1 and pyrin domain containing 3 (NLRP3) proteins in the renal tissues of rats. Results Compared with control group, serum BUN and Cr contents increased in the model rats; the secretion of inflammatory factors IL-1β and TNF-α, as well as the expressions of caspase-1 and NLRP3 were also enhanced in the model group. Compared with the model group, serum BUN and Cr contents decreased in the experimental groups; the secretion of IL-1β and TNF-α, as well as the expressions of caspase-1 and NLRP3 were also attenuated in the experimental groups. Moreover, with the increase of the injection dosage of pAd-CTRP6, the suppressive effect was gradually strengthened. Conclusion CTRP6 can attenuate gentamicin-induced acute renal injury in rats in a dose-dependent manner.

  11. Geldanamycin induces production of heat shock protein 70 and partially attenuates ototoxicity caused by gentamicin in the organ of Corti explants

    Directory of Open Access Journals (Sweden)

    Haupt Heidemarie

    2009-09-01

    Full Text Available Abstract Background Heat shock protein 70 (HSP70 protects inner ear cells from damage and death induced by e.g. heat or toxins. Benzoquinone ansamycin antibiotic geldanamycin (GA was demonstrated to induce the expression of HSP70 in various animal cell types. The aim of our study was to investigate whether GA induces HSP70 in the organ of Corti (OC, which contains the auditory sensory cells, and whether GA can protect these cells from toxicity caused by a common aminoglycoside antibiotic gentamicin. Methods To address these questions, we used the OC explants isolated from p3-p5 rats. As a read-out, we used RT-PCR, ELISA and immunofluorescence. Results We found that GA at the concentration of 2 μM efficiently induced HSP70 expression on mRNA and protein level in the OC explants. Confocal microscopy revealed that HSP70 induced by GA is expressed by hair cells and interdental cells of spiral limbus. Preincubation of explants with 2 μM GA prior to adding gentamicin (500 μM significantly reduced the loss of outer but not inner hair cells, suggesting different mechanisms of otoprotection needed for these two cell types. Conclusion GA induced HSP70 in the auditory sensory cells and partially protected them from toxicity of gentamicin. Understanding the molecular mechanisms of GA otoprotection may provide insights for preventative therapy of the hearing loss caused by aminoglycoside antibiotics.

  12. One dose per day compared to multiple doses per day of gentamicin for treatment of suspected or proven sepsis in neonates.

    Science.gov (United States)

    Rao, Shripada C; Srinivasjois, Ravisha; Moon, Kwi

    2016-12-06

    Animal studies and trials in older children and adults suggest that a 'one dose per day' regimen of gentamicin is superior to a 'multiple doses per day' regimen. To compare the efficacy and safety of one dose per day compared to multiple doses per day of gentamicin in suspected or proven sepsis in neonates. Eligible studies were identified by searching the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 3) in the Cochrane Library (searched 8 April 2016), MEDLINE (1966 to 8 April 2016), Embase (1980 to 8 April 2016), and CINAHL (December 1982 to 8 April 2016). All randomised or quasi-randomised controlled trials comparing one dose per day ('once a day') compared to multiple doses per day ('multiple doses a day') of gentamicin to newborn infants. Data collection and analysis was performed according to the standards of the Cochrane Neonatal Review Group. Eleven RCTs were included (N = 574) and 28 excluded. All except one study enrolled infants of more than 32 weeks' gestation. Limited information suggested that infants in both 'once a day' as well as 'multiple doses a day' regimens showed adequate clearance of sepsis (typical RR 1.00, 95% CI 0.84 to 1.19; typical RD 0.00, 95% CI -0.19 to 0.19; 3 trials; N = 37). 'Once a day' gentamicin regimen was associated with fewer failures to attain peak level of at least 5 µg/ml (typical RR 0.22, 95% CI 0.11 to 0.47; typical RD -0.13, 95% CI -0.19 to -0.08; number needed to treat for an additional beneficial outcome (NNTB) = 8; 9 trials; N = 422); and fewer failures to achieve trough levels of 2 µg/ml or less (typical RR 0.38, 95% CI 0.27 to 0.55; typical RD -0.22, 95% CI -0.29 to -0.15; NNTB = 4; 11 trials; N = 503). 'Once a day' gentamicin achieved higher peak levels (MD 2.58, 95% CI 2.26 to 2.89; 10 trials; N = 440) and lower trough levels (MD -0.57, 95% CI -0.69 to -0.44; 10 trials; N = 440) than 'multiple doses a day' regimen. There was no significant difference in ototoxicity between two groups

  13. Use of Gentamicine sulfate for the control of Pantoea agglomerans, contaminant of the Solanum tuberosum L cv. Desirée in vitro multiplication

    Directory of Open Access Journals (Sweden)

    Yelenys Alvarado-Capó

    2006-10-01

    Full Text Available Bacterial contamination is one of the principal problems of plant tissue culture. The use of natural or synthetic antimicrobial substances represent an alternative for it solution. In potato micropropagation bacterial contamination produce serious damages. In this paper the effect of Gentamicine sulfate on control of high frequently contaminant was evaluated. The microorganism was isolated from media culture of potato cv. Desirée in vitro plants in multiplication stage. Traditional tintorial, bioquemical and physiological test were performed for bacteria identification together with BIOLOG bacteria identification system. Besides, the minimal inhibitory concentration (MIC and minimal bactericidal concentration (MBC of Gentamicine sulfate were determined and it antimicrobial and phytotoxic effect in multiplication stage were evaluated too. Pantoea agglomerans was identificated as potato contaminant and show sensibility to Gentamicine sulfate. The MIC was 0.625 mg.l-1 and the MBC was 1.25 mg.l-1. The antibiotics controlled the contamination in the 80% of contaminated explants without phytotoxicity at 2.5 mg.l-1. Key words: bacteria, in vitro culture, microbial contamination, potato

  14. The development of polymeric pellicles with gentamicine sulfate for therapeutic correction of cervical erosion (pseudoerosion

    Directory of Open Access Journals (Sweden)

    T. M. Litvinenko

    2014-08-01

    Full Text Available Introduction.Cervical erosionsoccur in 12-15%gynaecological diseases. Erosion is a damage of epithelialmucous membrane or skin. Therapy of patients with cervical erosionsis based on selection of pathogeneticsubstantiative method of treatment. Bathes and irrigations with 20% protargol, alum, carbolic acid, potassium permanganate are used. But some authors admit the destructive influence of these procedures. Using of tampons with 10% sintomycine emulsion, cod liver oil, sea-buckthorn oil,kalanchoe sap, propolis, vagotil, cigerol, galantamine also doesn’t give desirable result. Recently polymeric pellicleswith antibacterial substances are widely used. The most perspective in this route are aminoglycoside antibiotics. That is why we chose gentamicine sulfate (broad-spectrum aminoglycoside antibiotic. The aim of study is the development of the optimal composition of vaginal pellicleswith gentamicine sulfate for gynaecological practice, scientifically substantiation of excipients: polymeric base and plasticizer. Results and discussion.Polymeric bases and plasticizers influence on gentamicine sulfate releasing from polimericpellicleshas been studied. Research on choice of optimal composition has been carried out by two-factor experiment plan. The next bases and plasticizers have been used: methylcellulose, sodium carboxymethylcellulose, soluble biopolymer, gelatin; glycerine, propylenglycol, polyethylene glycol, twin 80. Gentamicine sulfate content was 80 mg in one pellicle. Gentamicine sulfate releasing from polimericpellicleshas been investigated by the Kruvchinsky method, concentration of active substance has been detected after 45 min. As a result it has been established that base makes essential influence on the gentamicine sulfate releasing (Fexp.52,88>Ftabl. 3,9. The best plasticizer is glycerin and the most optimal base is gelatin. So the optimal composition for vaginal films has been chosen: Gentamicine sulfate0,08 g Glycerin0,7 g Gelatin0

  15. Bactericidal Effect of Pterostilbene Alone and in Combination with Gentamicin against Human Pathogenic Bacteria

    Directory of Open Access Journals (Sweden)

    Wee Xian Lee

    2017-03-01

    Full Text Available The antibacterial activity of pterostilbene in combination with gentamicin against six strains of Gram-positive and Gram-negative bacteria were investigated. The minimum inhibitory concentration and minimum bactericidal concentration of pterostilbene were determined using microdilution technique whereas the synergistic antibacterial activities of pterostilbene in combination with gentamicin were assessed using checkerboard assay and time-kill kinetic study. Results of the present study showed that the combination effects of pterostilbene with gentamicin were synergistic (FIC index < 0.5 against three susceptible bacteria strains: Staphylococcus aureus ATCC 25923, Escherichia coli O157 and Pseudomonas aeruginosa 15442. However, the time-kill study showed that the interaction was indifference which did not significantly differ from the gentamicin treatment. Furthermore, time-kill study showed that the growth of the tested bacteria was completely attenuated with 2 to 8 h treatment with 0.5 × MIC of pterostilbene and gentamicin. The identified combinations could be of effective therapeutic value against bacterial infections. These findings have potential implications in delaying the development of bacterial resistance as the antibacterial effect was achieved with the lower concentrations of antibacterial agents.

  16. Bactericidal Effect of Pterostilbene Alone and in Combination with Gentamicin against Human Pathogenic Bacteria.

    Science.gov (United States)

    Lee, Wee Xian; Basri, Dayang Fredalina; Ghazali, Ahmad Rohi

    2017-03-17

    The antibacterial activity of pterostilbene in combination with gentamicin against six strains of Gram-positive and Gram-negative bacteria were investigated. The minimum inhibitory concentration and minimum bactericidal concentration of pterostilbene were determined using microdilution technique whereas the synergistic antibacterial activities of pterostilbene in combination with gentamicin were assessed using checkerboard assay and time-kill kinetic study. Results of the present study showed that the combination effects of pterostilbene with gentamicin were synergistic (FIC index bacteria strains: Staphylococcus aureus ATCC 25923 , Escherichia coli O157 and Pseudomonas aeruginosa 15442 . However, the time-kill study showed that the interaction was indifference which did not significantly differ from the gentamicin treatment. Furthermore, time-kill study showed that the growth of the tested bacteria was completely attenuated with 2 to 8 h treatment with 0.5 × MIC of pterostilbene and gentamicin. The identified combinations could be of effective therapeutic value against bacterial infections. These findings have potential implications in delaying the development of bacterial resistance as the antibacterial effect was achieved with the lower concentrations of antibacterial agents.

  17. Administration of BMSCs with muscone in rats with gentamicin-induced AKI improves their therapeutic efficacy.

    Directory of Open Access Journals (Sweden)

    Pengfei Liu

    Full Text Available The therapeutic action of bone marrow-derived mesenchymal stem cells (BMSCs in acute kidney injury (AKI has been reported by several groups. However, recent studies indicated that BMSCs homed to kidney tissues at very low levels after transplantation. The lack of specific homing of exogenously infused cells limited the effective implementation of BMSC-based therapies. In this study, we provided evidence that the administration of BMSCs combined with muscone in rats with gentamicin-induced AKI intravenously, was a feasible strategy to drive BMSCs to damaged tissues and improve the BMSC-based therapeutic effect. The effect of muscone on BMSC bioactivity was analyzed in vitro and in vivo. The results indicated that muscone could promote BMSC migration and proliferation. Some secretory capacity of BMSC still could be improved in some degree. The BMSC-based therapeutic action was ameliorated by promoting the recovery of biochemical variables in urine or blood, as well as the inhibition of cell apoptosis and inflammation. In addition, the up-regulation of CXCR4 and CXCR7 expression in BMSCs could be the possible mechanism of muscone amelioration. Thus, our study indicated that enhancement of BMSCs bioactivities with muscone could increase the BMSC therapeutic potential and further developed a new therapeutic strategy for the treatment of AKI.

  18. Process for Selecting System Level Assessments for Human System Technologies

    Science.gov (United States)

    Watts, James; Park, John

    2006-01-01

    The integration of many life support systems necessary to construct a stable habitat is difficult. The correct identification of the appropriate technologies and corresponding interfaces is an exhaustive process. Once technologies are selected secondary issues such as mechanical and electrical interfaces must be addressed. The required analytical and testing work must be approached in a piecewise fashion to achieve timely results. A repeatable process has been developed to identify and prioritize system level assessments and testing needs. This Assessment Selection Process has been defined to assess cross cutting integration issues on topics at the system or component levels. Assessments are used to identify risks, encourage future actions to mitigate risks, or spur further studies.

  19. Hologenomics: Systems-Level Host Biology.

    Science.gov (United States)

    Theis, Kevin R

    2018-01-01

    The hologenome concept of evolution is a hypothesis explaining host evolution in the context of the host microbiomes. As a hypothesis, it needs to be evaluated, especially with respect to the extent of fidelity of transgenerational coassociation of host and microbial lineages and the relative fitness consequences of repeated associations within natural holobiont populations. Behavioral ecologists are in a prime position to test these predictions because they typically focus on animal phenotypes that are quantifiable, conduct studies over multiple generations within natural animal populations, and collect metadata on genetic relatedness and relative reproductive success within these populations. Regardless of the conclusion on the hologenome concept as an evolutionary hypothesis, a hologenomic perspective has applied value as a systems-level framework for host biology, including in medicine. Specifically, it emphasizes investigating the multivarious and dynamic interactions between patient genomes and the genomes of their diverse microbiota when attempting to elucidate etiologies of complex, noninfectious diseases.

  20. Repetitive Interrogation of 2-Level Quantum Systems

    Science.gov (United States)

    Prestage, John D.; Chung, Sang K.

    2010-01-01

    Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

  1. Atomic four-level N systems

    International Nuclear Information System (INIS)

    Goren, C.; Rosenbluh, M.; Wilson-Gordon, A.D.; Friedmann, H.

    2004-01-01

    We investigate the atomic four-level N configuration both analytically and numerically, for various pump and probe intensities, with and without transfer of coherence (TOC) and Doppler broadening, and compare the results obtained to those of realistic atomic systems. We find that TOC affects the whole spectrum, in addition to producing an electromagnetically induced absorption (EIA) peak at line center. We show that the EIA peak splits as the pump intensity increases. These results are compared with those of realistic systems. When the pump is σ + polarized and the probe is π polarized, the results are similar to those of the N configuration. When the pump and probe polarizations are both linear with perpendicular polarizations, various N-like subsystems contribute to the spectrum. Consequently, the splitting of the EIA peak only occurs at very high pump intensities. We also discuss the influence of the probe on the pump absorption and refraction and find that both the pump and probe show EIA peaks when the pump intensity is low, and complementary behavior when the pump is intense. At both low and high pump intensity, the pump and probe dispersions are of opposite sign

  2. General Tritium Labelling of Gentamicin C by catalytic hydrogen exchange Reaction with Tritiated Water

    International Nuclear Information System (INIS)

    Suarez, C.; Diaz, D.; Paz, D.

    1991-01-01

    Gentamicin C was labelled with tritium by means of a PtO2 catalyzed hydrogen exchange reaction. Under the conditions of the exchange (100 mg of gentamicin, basic form, 0,3 ml H2O-3H, and 50 mg of prereduced PtO2) the radiochemical yield was 0,24, 0,38 and 0,48 % at 120 degree celsius, for 8, 16 and 24 hours respectively. Chemical yield for purified gentamicin was about 60 %. Purification was accomplished with a cellulose column eluted with the lower phase of chloroform-methanol 17 % ammonium hydroxide (2:1:1, v/v) . Chemical purity, determined by HPLC, was 96,5 % and radiochemical one was 95. Main exchange degradation products show biological activity. (Author) 12 refs

  3. General Tritium labelling of gentamicin C by catalytic hydrogen exchange reaction with tritiated water

    International Nuclear Information System (INIS)

    Suarez, C.; Diaz, D.

    1991-01-01

    Gentamicin C was labelled with tritium by means of a PtO 2 catalized hydrogen exchange reaction. Under the conditions of the exchange (100 mg of gentamicin, basic form, 0,3 ml H 2 O- 3 H, and 50 mg of prereduced PtO 2 ) the radiochemical yield was 0,24, 0,38 and 0,48 % at 120 o C, for 8, 16 and 24 hours respectively. Chemical yield for purified gentamicin was about 60 %. Purification was accoumplished with a cellulose column eluted with the lower phase of chloroform-methanol 17 % ammonium hydroxide (2:1:1, v/v). Chemical purity, determined by HPLC, was 96,5 % and radiochemical one was 95 % . Main exchange degradation products show biological activity. (Author). 12 refs

  4. Novel pathways for ameliorating the fitness cost of gentamicin resistant small colony variants

    DEFF Research Database (Denmark)

    Vestergaard, Martin; Paulander, Wilhelm Erik Axel; Leng, Bingfeng

    2016-01-01

    Small colony variants (SCVs) of the human pathogen Staphylococcus aureus are associated with persistent infections. Phenotypically, SCVs are characterized by slow growth and they can arise upon interruption of the electron transport chain that consequently reduce membrane potential and thereby...... limit uptake of aminoglycosides (e.g., gentamicin). In this study, we have examined the pathways by which the fitness cost of SCVs can be ameliorated. Five gentamicin resistant SCVs derived from S. aureus JE2 were independently selected on agar plates supplemented with gentamicin. The SCVs carried...... mutations in the menaquinone and hemin biosynthesis pathways, which caused a significant reduction in exponential growth rates relative to wild type (WT; 0.59-0.72) and reduced membrane potentials. Fifty independent lineages of the low-fitness, resistant mutants were serially passaged for up to 500...

  5. Discontinuation of peri-operative gentamicin use for indwelling urinary catheter manipulation in orthopaedic surgery.

    Science.gov (United States)

    Bond, Stuart E; Boutlis, Craig S; Jansen, Stuart G; Miyakis, Spiros

    2017-11-01

    Gentamicin has historically been used prior to insertion and removal of indwelling urinary catheters (IDCs) around elective joint replacement surgery to prevent infection; however, this indication is not recognized in the Australian Therapeutic Guidelines: Antibiotic and the paradigm for safe use of gentamicin has shifted. The antimicrobial stewardship team of a 500 bed tertiary regional hospital performed a retrospective clinical study of gentamicin IDC prophylaxis around total hip and knee arthroplasties. Results were presented to the orthopaedic surgeons. A literature review identified no guidelines to support gentamicin prophylaxis and only a very low risk of bacteraemia associated with IDC insertion/removal in patients with established bacteriuria. Consensus was reached with the surgeons to discontinue this practice. Subsequent prospective data collection was commenced to determine effectiveness, with weekly feedback to the Department Head of Orthopaedics. Data from 137 operations pre-intervention (6 months) were compared with 205 operations post-intervention (12 months). The median patient age was 72 years in both groups. Following the intervention, reductions in gentamicin use were demonstrated for IDC insertion (59/137 (42%) to 4/205 (2%), P < 0.01) and removal (39/137 (28%) to 6/205 (3%), P < 0.01). No gentamicin use was observed during the final 40 weeks of the post-intervention period. There were no significant differences between the groups for pre-operative bacteriuria, surgical site infections or acute kidney injury. A collaborative approach using quality improvement methodology can lead to an evidence-based reappraisal of established practice. Regular rolling audits and timely feedback were useful in sustaining change. © 2016 Royal Australasian College of Surgeons.

  6. Efficacies of gentamicin-loaded magnetite block ionomer complexes against chronic Brucella melitensis infection

    International Nuclear Information System (INIS)

    Jain-Gupta, Neeta; Pothayee, Nipon; Pothayee, Nikorn; Tyler, Ronald; Caudell, David L.; Balasubramaniam, Sharavanan; Hu, Nan; Davis, Richey M.; Riffle, Judy S.; Sriranganathan, Nammalwar

    2013-01-01

    Anionic copolymers can enable intracellular delivery of cationic drugs which otherwise cannot cross cell membrane barriers. We tested the efficacy of gentamicin-loaded magnetite block ionomer complexes (MBICs) against intracellular Brucella melitensis. Anionic block copolymers were used to coat nanomagnetite through adsorption of a portion of anions on the particle surfaces, then the remaining anions were complexed with 30–32 weight percentage of gentamicin. The zeta potential changed from −39 to −13 mV after encapsulation of the drug with complementary charge. The gentamicin-loaded MBICs had intensity average hydrodynamic diameters of 62 nm, while the polymer-coated nanomagnetite particles without drug were 34 nm in size. No toxicity as measured by a MTS assay was observed upon incubation of the MBICs with J774A.1 murine macrophage-like cells. Confocal microscopic images showed that the MBICs were taken up by the macrophages and distributed in the cell cytoplasm and endosomal/lysosomal compartments. Upon treatment with gentamicin-loaded MBICs (3.5 Log 10 ), B. melitensis-infected macrophages showed significantly higher clearance of Brucella compared to the treatment with free g (0.9 Log 10 ). Compared to doxycycline alone, a combination of doxycycline and gentamicin (either free or encapsulated in MBICs) showed significantly higher clearance of B.melitensis from chronically infected mice. Histopathological examination of kidneys from the MBICs-treated mice revealed multifocal infiltration of macrophages containing intracytoplasmic iron (MBICs) in peri-renal adipose. Although MBICs showed similar efficacy as free gentamicin against Brucella in mice, our strategy presents an effective way to deliver higher loads of drugs intracellularly and ability to study the bio-distribution of drug carriers

  7. Efficacies of gentamicin-loaded magnetite block ionomer complexes against chronic Brucella melitensis infection

    Energy Technology Data Exchange (ETDEWEB)

    Jain-Gupta, Neeta [Virginia-Maryland Regional College of Veterinary Medicine, Virginia Polytechnic Institute and State University, Department of Biomedical Sciences and Pathobiology (United States); Pothayee, Nipon; Pothayee, Nikorn [Virginia Polytechnic Institute and State University, Macromolecules and Interfaces Institute (United States); Tyler, Ronald; Caudell, David L. [Virginia-Maryland Regional College of Veterinary Medicine, Virginia Polytechnic Institute and State University, Department of Biomedical Sciences and Pathobiology (United States); Balasubramaniam, Sharavanan; Hu, Nan; Davis, Richey M.; Riffle, Judy S. [Virginia Polytechnic Institute and State University, Macromolecules and Interfaces Institute (United States); Sriranganathan, Nammalwar, E-mail: nathans@vt.edu [Virginia-Maryland Regional College of Veterinary Medicine, Virginia Polytechnic Institute and State University, Department of Biomedical Sciences and Pathobiology (United States)

    2013-11-15

    Anionic copolymers can enable intracellular delivery of cationic drugs which otherwise cannot cross cell membrane barriers. We tested the efficacy of gentamicin-loaded magnetite block ionomer complexes (MBICs) against intracellular Brucella melitensis. Anionic block copolymers were used to coat nanomagnetite through adsorption of a portion of anions on the particle surfaces, then the remaining anions were complexed with 30–32 weight percentage of gentamicin. The zeta potential changed from −39 to −13 mV after encapsulation of the drug with complementary charge. The gentamicin-loaded MBICs had intensity average hydrodynamic diameters of 62 nm, while the polymer-coated nanomagnetite particles without drug were 34 nm in size. No toxicity as measured by a MTS assay was observed upon incubation of the MBICs with J774A.1 murine macrophage-like cells. Confocal microscopic images showed that the MBICs were taken up by the macrophages and distributed in the cell cytoplasm and endosomal/lysosomal compartments. Upon treatment with gentamicin-loaded MBICs (3.5 Log{sub 10}), B. melitensis-infected macrophages showed significantly higher clearance of Brucella compared to the treatment with free g (0.9 Log{sub 10}). Compared to doxycycline alone, a combination of doxycycline and gentamicin (either free or encapsulated in MBICs) showed significantly higher clearance of B.melitensis from chronically infected mice. Histopathological examination of kidneys from the MBICs-treated mice revealed multifocal infiltration of macrophages containing intracytoplasmic iron (MBICs) in peri-renal adipose. Although MBICs showed similar efficacy as free gentamicin against Brucella in mice, our strategy presents an effective way to deliver higher loads of drugs intracellularly and ability to study the bio-distribution of drug carriers.

  8. Efficacies of gentamicin-loaded magnetite block ionomer complexes against chronic Brucella melitensis infection

    Science.gov (United States)

    Jain-Gupta, Neeta; Pothayee, Nipon; Pothayee, Nikorn; Tyler, Ronald; Caudell, David L.; Balasubramaniam, Sharavanan; Hu, Nan; Davis, Richey M.; Riffle, Judy S.; Sriranganathan, Nammalwar

    2013-11-01

    Anionic copolymers can enable intracellular delivery of cationic drugs which otherwise cannot cross cell membrane barriers. We tested the efficacy of gentamicin-loaded magnetite block ionomer complexes (MBICs) against intracellular Brucella melitensis. Anionic block copolymers were used to coat nanomagnetite through adsorption of a portion of anions on the particle surfaces, then the remaining anions were complexed with 30-32 weight percentage of gentamicin. The zeta potential changed from -39 to -13 mV after encapsulation of the drug with complementary charge. The gentamicin-loaded MBICs had intensity average hydrodynamic diameters of 62 nm, while the polymer-coated nanomagnetite particles without drug were 34 nm in size. No toxicity as measured by a MTS assay was observed upon incubation of the MBICs with J774A.1 murine macrophage-like cells. Confocal microscopic images showed that the MBICs were taken up by the macrophages and distributed in the cell cytoplasm and endosomal/lysosomal compartments. Upon treatment with gentamicin-loaded MBICs (3.5 Log10), B. melitensis-infected macrophages showed significantly higher clearance of Brucella compared to the treatment with free g (0.9 Log10). Compared to doxycycline alone, a combination of doxycycline and gentamicin (either free or encapsulated in MBICs) showed significantly higher clearance of B. melitensis from chronically infected mice. Histopathological examination of kidneys from the MBICs-treated mice revealed multifocal infiltration of macrophages containing intracytoplasmic iron (MBICs) in peri-renal adipose. Although MBICs showed similar efficacy as free gentamicin against Brucella in mice, our strategy presents an effective way to deliver higher loads of drugs intracellularly and ability to study the bio-distribution of drug carriers.

  9. Kinetics and dose calculations of ampicillin and gentamicin given as continuous intravenous infusion during parenteral nutrition in 88 newborn infants

    DEFF Research Database (Denmark)

    Colding, H; Møller, S; Bentzon, M W

    1983-01-01

    Ampicillin and gentamicin were administered continuously intravenously to 88 newborn infants using individually calculated dosages. For infants with a mean value of plasma clearance of the antibiotics, it was calculated that the serum ampicillin and gentamicin concentrations would be between 35-5...

  10. Gentamicin coating of plasma chemical oxidized titanium alloy prevents implant-related osteomyelitis in rats.

    Science.gov (United States)

    Diefenbeck, M; Schrader, C; Gras, F; Mückley, T; Schmidt, J; Zankovych, S; Bossert, J; Jandt, K D; Völpel, A; Sigusch, B W; Schubert, H; Bischoff, S; Pfister, W; Edel, B; Faucon, M; Finger, U

    2016-09-01

    Implant related infection is one of the most feared and devastating complication associated with the use of orthopaedic implant devices. Development of anti-infective surfaces is the main strategy to prevent implant contamination, biofilm formation and implant related osteomyelitis. A second concern in orthopaedics is insufficient osseointegration of uncemented implant devices. Recently, we reported on a macroporous titanium-oxide surface (bioactive TiOB) which increases osseointegration and implant fixation. To combine enhanced osseointegration and antibacterial function, the TiOB surfaces were, in addition, modified with a gentamicin coating. A rat osteomyelitis model with bilateral placement of titanium alloy implants was employed to analyse the prophylactic effect of gentamicin-sodiumdodecylsulfate (SDS) and gentamicin-tannic acid coatings in vivo. 20 rats were randomly assigned to four groups: (A) titanium alloy; PBS inoculum (negative control), (B) titanium alloy, Staphylococcus aureus inoculum (positive control), (C) bioactive TiOB with gentamicin-SDS and (D) bioactive TiOB plus gentamicin-tannic acid coating. Contamination of implants, bacterial load of bone powder and radiographic as well as histological signs of implant-related osteomyelitis were evaluated after four weeks. Gentamicin-SDS coating prevented implant contamination in 10 of 10 tibiae and gentamicin-tannic acid coating in 9 of 10 tibiae (infection prophylaxis rate 100% and 90% of cases, respectively). In Group (D) one implant showed colonisation of bacteria (swab of entry point and roll-out test positive for S. aureus). The interobserver reliability showed no difference in the histologic and radiographic osteomyelitis scores. In both gentamicin coated groups, a significant reduction of the histological osteomyelitis score (geometric mean values: C = 0.111 ± 0.023; D = 0.056 ± 0.006) compared to the positive control group (B: 0.244 ± 0.015; p < 0.05) was observed. The

  11. Auditory function after continuous infusion of gentamicin to high-risk newborns

    DEFF Research Database (Denmark)

    Colding, H; Andersen, E A; Prytz, S

    1989-01-01

    Audiometry was performed at four years of age in 69 of 105 surviving children who had received continuous intravenous infusion of gentamicin during neonatal intensive care. A hearing loss of 20 dB was found in 2 of them (3%), corresponding to that shown in other studies of survivors following...... neonatal intensive care. Free field audiometry performed in another 7 children and questionnaires returned from 13 of the remaining 29 gave no suspicion of hearing loss. Thus there is no indication that continuous 24 hours intravenous infusion of gentamicin causes more hearing impairment than intermittent...

  12. System Level Modelling and Performance Estimation of Embedded Systems

    DEFF Research Database (Denmark)

    Tranberg-Hansen, Anders Sejer

    The advances seen in the semiconductor industry within the last decade have brought the possibility of integrating evermore functionality onto a single chip forming functionally highly advanced embedded systems. These integration possibilities also imply that as the design complexity increases, so...... does the design time and eort. This challenge is widely recognized throughout academia and the industry and in order to address this, novel frameworks and methods, which will automate design steps as well as raise the level of abstraction used to design systems, are being called upon. To support...... is carried out in collaboration with the Danish company and DaNES partner, Bang & Olufsen ICEpower. Bang & Olufsen ICEpower provides industrial case studies which will allow the proposed modelling framework to be exercised and assessed in terms of ease of use, production speed, accuracy and efficiency...

  13. Gentamicin-intercalated smectite as a new therapeutic option for Helicobacter pylori eradication.

    Science.gov (United States)

    Jeong, Su Jin; Kim, Jie-Hyun; Jung, Da Hyun; Lee, Kyoung Hwa; Park, Soon Young; Song, Yungoo; Kang, Il-Mo; Song, Young Goo

    2018-02-12

    Novel antibacterial strategies against Helicobacter pylori are needed because H. pylori strains are acquiring resistance to antibiotics. We evaluated the efficacy of gentamicin-intercalated smectite hybrid (S-GEN)-based treatment regimens in a murine model of H. pylori infection. Two groups of 10 rats were administered either smectite or S-GEN to measure coverage of the gastric mucosa. To evaluate anti-H. pylori efficacy, mice were divided into eight groups of 10 mice each given different treatments, and H. pylori eradication was assessed by a Campylobacter-like organism (CLO) test and H. pylori PCR of the gastric mucosa, and H. pylori antigen and H. pylori PCR analysis of mouse faeces. The levels of proinflammatory cytokines were examined. S-GEN was retained in the gastric mucosal layer with a >60% distribution ratio for up to 1 h, and the S-GEN-based triple regimen decreased bacterial burden in vivo compared with that of untreated mice or mice treated with other regimens. The cure rates in the CLO test and H. pylori PCR from gastric mucosa were 70%, 60%, 80%, 50%, 60% and 60% in Groups III-VIII, respectively. Those for H. pylori PCR in the faeces of mice were 90% and 100% in Group III with standard therapy and Group V with triple therapy including S-GEN, respectively. S-GEN triple therapy also reduced the levels of proinflammatory cytokines. These results suggest that S-GEN is a promising and effective therapeutic agent for the treatment of H. pylori infection. © The Author(s) 2018. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Chitosan Prevents Gentamicin-Induced Nephrotoxicity via a Carbonyl Stress-Dependent Pathway

    Directory of Open Access Journals (Sweden)

    Chu-Kung Chou

    2015-01-01

    Full Text Available Aminoglycosides are widely used to treat infections; however, their applications are limited by nephrotoxicity. With the increase of antibiotic resistance, the use of aminoglycosides is inevitable. Low-molecular-weight chitosan (LMWC has shown renal protective effects in dialysis patients. However, no study has evaluated LMWC for preventing aminoglycoside-induced nephrotoxicity or determined the mechanisms underlying the renal protective effects. In this study, LMWC (165 or 825 mg/kg/day or metformin (100 mg/kg/day was orally administered for 13 days to rats with nephropathy induced by gentamicin (GM, a kind of aminoglycoside (150 mg/kg/day i.p. for 6 days. Both LMCW doses improved renal function. Serum creatinine levels improved in rats treated with 165 and 825 mg/kg/day LMWC (from 2.14 ± 0.74 mg/dL to 1.26 ± 0.46 mg/dL and 0.69 ± 0.12 mg/dL, resp., P < 0.05. Blood urea nitrogen levels were also improved in these rats (from 73.73 ± 21.13 mg/dL to 58.70 ± 22.71 mg/dL and 28.82 ± 3.84 mg/dL, resp., P < 0.05. Additionally, renal tissue morphology improved after LMWC treatment, and accumulation of renal methylglyoxal, a damage factor associated with carbonyl stress, was reversed. These results show that LMWC prevents GM-induced renal toxicity via a carbonyl stress-dependent pathway.

  15. Occurrence of airborne vancomycin- and gentamicin-resistant bacteria in various hospital wards in Isfahan, Iran.

    Science.gov (United States)

    Mirhoseini, Seyed Hamed; Nikaeen, Mahnaz; Khanahmad, Hossein; Hassanzadeh, Akbar

    2016-01-01

    Airborne transmission of pathogenic resistant bacteria is well recognized as an important route for the acquisition of a wide range of nosocomial infections in hospitals. The aim of this study was to determine the prevalence of airborne vancomycin and gentamicin (VM and GM) resistant bacteria in different wards of four educational hospitals. A total of 64 air samples were collected from operating theater (OT), Intensive Care Unit (ICU), surgery ward, and internal medicine ward of four educational hospitals in Isfahan, Iran. Airborne culturable bacteria were collected using all glass impingers. Samples were analyzed for the detection of VM- and GM-resistant bacteria. The average level of bacteria ranged from 99 to 1079 CFU/m(3). The highest level of airborne bacteria was observed in hospital 4 (628 CFU/m(3)) and the highest average concentration of GM- and VM-resistant airborne bacteria were found in hospital 3 (22 CFU/m(3)). The mean concentration of airborne bacteria was the lowest in OT wards and GM- and VM-resistant airborne bacteria were not detected in this ward of hospitals. The highest prevalence of antibiotic-resistant airborne bacteria was observed in ICU ward. There was a statistically significant difference for the prevalence of VM-resistant bacteria between hospital wards (P = 0.012). Our finding showed that the relatively high prevalence of VM- and GM-resistant airborne bacteria in ICUs could be a great concern from the point of view of patients' health. These results confirm the necessity of application of effective control measures which significantly decrease the exposure of high-risk patients to potentially airborne nosocomial infections.

  16. Alteration of renal excretion pathways in gentamicin-induced renal injury in rats.

    Science.gov (United States)

    Ma, Yan-Rong; Luo, Xuan; Wu, Yan-Fang; Zhang, Tiffany; Zhang, Fan; Zhang, Guo-Qiang; Wu, Xin-An

    2018-02-20

    The kidney plays a major part in the elimination of many drugs and their metabolites, and drug-induced kidney injury commonly alters either glomerular filtration or tubular transport, or both. However, the renal excretion pathway of drugs has not been fully elucidated at different stages of renal injury. This study aimed to evaluate the alteration of renal excretion pathways in gentamicin (GEN)-induced renal injury in rats. Results showed that serum cystatin C, creatinine and urea nitrogen levels were greatly increased by the exposure of GEN (100 mg kg -1 ), and creatinine concentration was increased by 39.7% by GEN (50 mg kg -1 ). GEN dose-dependently upregulated the protein expression of rOCT1, downregulated rOCT2 and rOAT1, but not affected rOAT2. Efflux transporters, rMRP2, rMRP4 and rBCRP expressions were significantly increased by GEN(100), and the rMATE1 level was markedly increased by GEN(50) but decreased by GEN(100). GEN(50) did not alter the urinary excretion of inulin, but increased metformin and furosemide excretion. However, GEN(100) resulted in a significant decrease of the urinary excretion of inulin, metformin and p-aminohippurate. In addition, urinary metformin excretions in vivo were significantly decreased by GEN(100), but slightly increased by GEN(50). These results suggested that GEN(50) resulted in the induction of rOCTs-rMATE1 and rOAT3-rMRPs pathway, but not changed the glomerular filtration rate, and GEN(100)-induced acute kidney injury caused the downregulated function of glomerular filtration -rOCTs-rMATE1 and -rOAT1-rMRPs pathway. Copyright © 2018 John Wiley & Sons, Ltd.

  17. 75 FR 54492 - Ophthalmic and Topical Dosage Form New Animal Drugs; Gentamicin and Betamethasone Ophthalmic...

    Science.gov (United States)

    2010-09-08

    ... Ophthalmic Solution AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; technical amendment... acetate ophthalmic solution. This action is being taken to comply with the Federal Food, Drug, and... GENTOCIN DURAFILM (gentamicin sulfate and betamethasone acetate) Ophthalmic Solution, sponsored by Intervet...

  18. Staphylococcus aureus biofilm formation on different gentamicin-loaded polymethylmethacrylate bone cements

    NARCIS (Netherlands)

    van de Belt, H; Neut, D; Schenk, W; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    In this in vitro study, the formation of a Staphylococcus aureus biofilm on six gentamicin-loaded bone cements (CMW1, CMW3, CMW Endurance, CMW2000, Palacos. and Palamed) was determined in a modified Robbins device over a 3 days time span and related with previously (Van de Belt et al., Biomaterials

  19. Refractory episodic vertigo: role of intratympanic gentamicin and vestibular evoked myogenic potentials,

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    Full Text Available Abstract Introduction: Even today, the treatment of intractable vertigo remains a challenge. Vestibular ablation with intratympanic gentamicin stands as a good alternative in the management of refractory vertigo patients. Objective: To control intractable vertigo through complete saccular and horizontal canal vestibular ablation with intratympanic gentamicin treatment. Methods: Patients with refractory episodic vertigo were included. The inclusion criteria were: unilateral ear disease, moderate to profound sensorineural hearing loss, and failure to other treatments. Included patients underwent 0.5-0.8 mL of gentamicin intratympanic application at a 30 mg/mL concentration. Vestibular ablation was confirmed by the absence of response on cervical vestibular evoked myogenic potentials and no response on caloric tests. Audiometry, electronystagmography with iced water, and vestibular evoked myogenic potentials were performed in all patients. Results: Ten patients were included; nine patients with Meniere's disease and one patient with (late onset delayed hydrops. Nine patients showed an absent response on vestibular evoked myogenic potentials and no response on caloric tests. The only patient with low amplitude on cervical vestibular evoked myogenic potentials had vertigo recurrence. Vertigo control was achieved in 90% of the patients. One patient developed hearing loss >30 dB. Conclusions: Cervical vestibular evoked myogenic potentials confirmed vestibular ablation in patients treated with intratympanic gentamicin. High-grade vertigo control was due to complete saccular and horizontal canal ablation (no response to iced water in electronystagmography and no response on cervical vestibular evoked myogenic potentials.

  20. Continuous intravenous infusion of ampicillin and gentamicin during parenteral nutrition in 88 newborn infants

    DEFF Research Database (Denmark)

    Colding, H; Møller, S; Andersen, G E

    1982-01-01

    Ampicillin and gentamicin were dissolved once a day in an L-amino acid solution especially prepared for parenteral nutrition of newborn infants and infused continuously to 88 infants in whom septicaemia was suspected or had been proved. The mean dosages were 162 and 5.3 mg/kg per 24 hours...

  1. Population pharmacokinetics and relationship between demographic and clinical variables and pharmacokinetics of gentamicin in neonates

    NARCIS (Netherlands)

    Stolk, L M L; Degraeuwe, P L J; Nieman, F H M; de Wolf, M C; de Boer, A|info:eu-repo/dai/nl/075097346

    Population pharmacokinetic parameter estimates were calculated from 725 routine plasma gentamicin concentrations obtained in 177 neonates of 24 to 42 weeks' gestational age in their first week of life. Kel increases and V/W decreases with increasing gestational age. Almost identical results were

  2. Studies of labelling conditions for gentamicin with99mTc Biological uptake

    International Nuclear Information System (INIS)

    Carvalho, O.G. de; Almeida, M.A.T.M. de; Muramoto, E.

    1989-10-01

    Gentamicin sulphate is an aminoglycoside antibiotic type specifically used for treatment of infections produced by Gram-negative bacterias but on the hand it presents ototoxic reactions as a serious side effect. The optimal labelling conditions of gentamicin sulphate with 99m Tc, using sodium pertechnetate solutions eluted from a 99 Mo - 99m Tc generator, were stablished by testing differents masses of antibiotic and reducing agent (SnCl 2 .2H 2 O), and also different reaction times and final labelling pH. The labelling yields were determined through ascendent type crimatographic analysis using metylacetone and 0,9% NaCl solution as solvents. From the studies of the biological uptake of 99m Tc gentamicin sulphate per gram of eight different organs and tissues from Wistar rats, it was shown that for a dose of 0,3 mg of 99m Tc-gentamicin intravenously administered. The kidneys, presented the greatest affinity for the drug, being thus the main excretory organs of the product. (author) [pt

  3. Administration of gentamicin and ampicillin by continuous intravenous infusion to newborn infants during parenteral nutrition

    DEFF Research Database (Denmark)

    Colding, H; Andersen, G E

    1982-01-01

    Gentamicin and ampicillin were dissolved in an L-amino acid solution especially prepared for newborn infants and infused intravenously over 24 h in 7 babies with serious neonatal surgical problems. Serum concentrations of the antibiotics were maintained rather constant and well above the minimal ...

  4. Microbubble-Mediated Ultrasound Enhances the Lethal Effect of Gentamicin on Planktonic Escherichia coli

    Directory of Open Access Journals (Sweden)

    Han-Xiao Zhu

    2014-01-01

    Full Text Available Previous research has found that low-intensity ultrasound enhanced the lethal effect of gentamicin on planktonic E. coli. We aimed to further investigate whether microbubble-mediated low-intensity ultrasound could further enhance the antimicrobial efficacy of gentamicin. The planktonic E. coli (ATCC 25922 was distributed to four different interventions: control (GCON, microbubble only (GMB, ultrasound only (GUS, and microbubble-mediated ultrasound (GMUS. Ultrasound was applied with 100 mW/cm2 (average intensity and 46.5 KHz, which presented no bactericidal activity. After 12 h, plate counting was used to estimate the number of bacteria, and bacterial micromorphology was observed with transmission electron microscope. The results showed that the viable counts of E. coli in GMUS were decreased by 1.01 to 1.42 log10 CFU/mL compared with GUS (P<0.01. The minimal inhibitory concentration (MIC of gentamicin against E. coli was 1 μg/mL in the GMUS and GUS groups, lower than that in the GCON and GMB groups (2 μg/mL. Transmission electron microscopy (TEM images exhibited more destruction and higher thickness of bacterial cell membranes in the GMUS than those in other groups. The reason might be the increased permeability of cell membranes for gentamicin caused by acoustic cavitation.

  5. Inhalational Gentamicin Treatment Is Effective Against Pneumonic Plague in a Mouse Model

    Directory of Open Access Journals (Sweden)

    David Gur

    2018-04-01

    Full Text Available Pneumonic plague is an infectious disease characterized by rapid and fulminant development of acute pneumonia and septicemia that results in death within days of exposure. The causative agent of pneumonic plague, Yersinia pestis (Y. pestis, is a Tier-1 bio-threat agent. Parenteral antibiotic treatment is effective when given within a narrow therapeutic window after symptom onset. However, the non-specific “flu-like” symptoms often lead to delayed diagnosis and therapy. In this study, we evaluated inhalational gentamicin therapy in an infected mouse model as a means to improve antibiotic treatment efficacy. Inhalation is an attractive route for treating lung infections. The advantages include directly dosing the main infection site, the relative accessibility for administration and the lack of extensive enzymatic drug degradation machinery. In this study, we show that inhalational gentamicin treatment administered 24 h post-infection, prior to the appearance of symptoms, protected against lethal intranasal challenge with the fully virulent Y. pestis Kimberley53 strain (Kim53. Similarly, a high survival rate was demonstrated in mice treated by inhalation with another aminoglycoside, tobramycin, for which an FDA-approved inhaled formulation is clinically available for cystic fibrosis patients. Inhalational treatment with gentamicin 48 h post-infection (to symptomatic mice was also successful against a Y. pestis challenge dose of 10 i.n.LD50. Whole-body imaging using IVIS technology demonstrated that adding inhalational gentamicin to parenteral therapy accelerated the clearance of Y. pestis from the lungs of infected animals. This may reduce disease severity and the risk of secondary infections. In conclusion, our data suggest that inhalational therapy with aerosolized gentamicin may be an effective prophylactic treatment against pneumonic plague. We also demonstrate the benefit of combining this treatment with a conventional parenteral

  6. Comparative activities of telavancin combined with nafcillin, imipenem, and gentamicin against Staphylococcus aureus.

    Science.gov (United States)

    Leonard, Steven N; Supple, Megan E; Gandhi, Ronak G; Patel, Meghna D

    2013-06-01

    Beta-lactams enhance the killing activity of vancomycin. Due to structural and mechanistic similarities between vancomycin and telavancin, we investigated the activity of telavancin combined with nafcillin and imipenem compared to the known synergistic combination of telavancin and gentamicin. Thirty strains of Staphylococcus aureus, 10 methicillin-susceptible S. aureus (MSSA), 10 methicillin-resistant S. aureus (MRSA), and 10 heterogeneously vancomycin-intermediate S. aureus (hVISA), were tested for synergy by time-kill methodology. Six strains (2 each of MSSA, MRSA, and hVISA) were further evaluated in an in vitro pharmacokinetic/pharmacodynamic (PK/PD) model with simulated regimens of 10 mg/kg of body weight of telavancin once daily alone and combined with 2 g nafcillin every 4 h, 500 mg imipenem every 6 h, or 5 mg/kg gentamicin once daily over 72 h. In the synergy test, 67% of strains displayed synergy with the combination of telavancin and gentamicin, 70% with telavancin and nafcillin, and 63% with telavancin and imipenem. In the PK/PD model, the activities of all three combinations against MRSA and hVISA were superior to all individual drugs alone (P ≤ 0.002) and were similar to each other (P ≥ 0.187). The activities of all three combinations against MSSA were generally similar to each other except for one strain where the combination of telavancin and imipenem was superior to all other regimens (P ≤ 0.011). The activity of the combination of telavancin and beta-lactam agents was similar to that of telavancin and gentamicin against S. aureus, including resistant strains. Because beta-lactam combinations are less likely to be nephrotoxic than telavancin plus gentamicin, these beta-lactam combinations may have clinical utility.

  7. Gentamicin-induced apoptosis in LLC-PK1 cells: Involvement of lysosomes and mitochondria

    International Nuclear Information System (INIS)

    Servais, Helene; Van Der Smissen, Patrick; Thirion, Gaetan; Van der Essen, Gauthier; Van Bambeke, Francoise; Tulkens, Paul M.; Mingeot-Leclercq, Marie-Paule

    2005-01-01

    Gentamicin accumulates in lysosomes and induces apoptosis in kidney proximal tubules and renal cell lines. Using LLC-PK1 cells, we have examined the concentration- and time-dependency of the effects exerted by gentamicin (1-3 mM; 0-3 days) on (i) lysosomal stability; (ii) activation of mitochondrial pathway; (iii) occurrence of apoptosis (concentrations larger than 3 mM caused extensive necrosis as assessed by the measurement of lactate dehydrogenase release). Within 2 h, gentamicin induced a partial relocalization [from lysosomes to cytosol] of the weak organic base acridine orange. We thereafter observed (a) a loss of mitochondrial membrane potential (as from 10 h, based on spectrophotometric and confocal microscopy using JC1 probe) and (b) the release of cytochrome c from granules to cytosol, and the activation of caspase-9 (as from 12 h; evidenced by Western blot analysis). Increase in caspase-3 activity (assayed with Ac-DEVD-AFC in the presence of z-VAD-fmk]) and appearance of fragmented nuclei (DAPI staining) was then detected as from 16 to 24 h together with nuclear fragmentation. Gentamicin produces a fast (within 4 h) release of calcein from negatively-charged liposomes at pH 5.4, which was slowed down by raising the pH to 7.4, or when phosphatidylinositol was replaced by cardiolipin (to mimic the inner mitochondrial membrane). The present data provide temporal evidence that gentamicin causes apoptosis in LLC-PK1 with successive alteration of the permeability of lysosomes, triggering of the mitochondrial pathway, and activation of caspase-3

  8. Radiation sensitivity of Salmonella isolates relative to resistance to ampicillin, chloramphenicol or gentamicin

    Science.gov (United States)

    Niemira, Brendan A.; Lonczynski, Kelly A.; Sommers, Christopher H.

    2006-09-01

    Antibiotic resistance of inoculated bacteria is a commonly used selective marker. Bacteria resistant to the antibiotic nalidixic acid have been shown to have an increased sensitivity to irradiation. The purpose of this research was to screen a collection of Salmonella isolates for antibiotic resistance and determine the association, if any, of antibiotic resistance with radiation sensitivity. Twenty-four clinical isolates of Salmonella were screened for native resistance to multiple concentrations of ampicillin (Amp), chloramphenicol (Chl), or gentamicin (Gm). Test concentrations were chosen based on established clinical minimum inhibitory concentration (MIC) levels, and isolates were classified as either sensitive or resistant based on their ability to grow at or above the MIC. Salmonella cultures were grown overnight at (37 °C) in antibiotic-amended tryptic soy broth (TSB). Native resistance to Gm was observed with each of the 24 isolates (100%). Eight isolates (33%) were shown to be resistant to Amp, while seven isolates (29%) were shown to be resistant to Chl. In separate experiments, Salmonella cultures were grown overnight (37 °C) in TSB, centrifuged, and the cell pellets were re-suspended in phosphate buffer. The samples were then gamma irradiated at doses up to 1.0 kGy. The D10 values (the ionizing radiation dose required to reduce the viable number of microorganisms by 90%) were determined for the 24 isolates and they ranged from 0.181 to 0.359 kGy. No correlation was found between the D10 value of the isolate and its sensitivity or resistance to each of the three antibiotics. Resistance to Amp or Chl is suggested as appropriate resistance marker for Salmonella test strains to be used in studies of irradiation.

  9. Radiation sensitivity of Salmonella isolates relative to resistance to ampicillin, chloramphenicol or gentamicin

    International Nuclear Information System (INIS)

    Niemira, Brendan A.; Lonczynski, Kelly A.; Sommers, Christopher H.

    2006-01-01

    Antibiotic resistance of inoculated bacteria is a commonly used selective marker. Bacteria resistant to the antibiotic nalidixic acid have been shown to have an increased sensitivity to irradiation. The purpose of this research was to screen a collection of Salmonella isolates for antibiotic resistance and determine the association, if any, of antibiotic resistance with radiation sensitivity. Twenty-four clinical isolates of Salmonella were screened for native resistance to multiple concentrations of ampicillin (Amp), chloramphenicol (Chl), or gentamicin (Gm). Test concentrations were chosen based on established clinical minimum inhibitory concentration (MIC) levels, and isolates were classified as either sensitive or resistant based on their ability to grow at or above the MIC. Salmonella cultures were grown overnight at (37 o C) in antibiotic-amended tryptic soy broth (TSB). Native resistance to Gm was observed with each of the 24 isolates (100%). Eight isolates (33%) were shown to be resistant to Amp, while seven isolates (29%) were shown to be resistant to Chl. In separate experiments, Salmonella cultures were grown overnight (37 o C) in TSB, centrifuged, and the cell pellets were re-suspended in phosphate buffer. The samples were then gamma irradiated at doses up to 1.0 kGy. The D 10 values (the ionizing radiation dose required to reduce the viable number of microorganisms by 90%) were determined for the 24 isolates and they ranged from 0.181 to 0.359 kGy. No correlation was found between the D 10 value of the isolate and its sensitivity or resistance to each of the three antibiotics. Resistance to Amp or Chl is suggested as appropriate resistance marker for Salmonella test strains to be used in studies of irradiation

  10. Naringin ameliorates gentamicin-induced nephrotoxicity and associated mitochondrial dysfunction, apoptosis and inflammation in rats: Possible mechanism of nephroprotection

    Energy Technology Data Exchange (ETDEWEB)

    Sahu, Bidya Dhar [Medicinal Chemistry and Pharmacology Division, Indian Institute of Chemical Technology (IICT), Hyderabad 500 007 (India); Tatireddy, Srujana [National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad 500 037 (India); Koneru, Meghana [Medicinal Chemistry and Pharmacology Division, Indian Institute of Chemical Technology (IICT), Hyderabad 500 007 (India); Borkar, Roshan M. [National Centre for Mass Spectrometry, Indian Institute of Chemical Technology (IICT), Hyderabad 500 007 (India); Kumar, Jerald Mahesh [CSIR-Centre for Cellular and Molecular Biology (CCMB), Hyderabad 500 007 (India); Kuncha, Madhusudana [Medicinal Chemistry and Pharmacology Division, Indian Institute of Chemical Technology (IICT), Hyderabad 500 007 (India); Srinivas, R. [National Centre for Mass Spectrometry, Indian Institute of Chemical Technology (IICT), Hyderabad 500 007 (India); Shyam Sunder, R. [Faculty of Pharmacy, Osmania University, Hyderabad 500 007 (India); Sistla, Ramakrishna, E-mail: sistla@iict.res.in [Medicinal Chemistry and Pharmacology Division, Indian Institute of Chemical Technology (IICT), Hyderabad 500 007 (India)

    2014-05-15

    Gentamicin-induced nephrotoxicity has been well documented, although its underlying mechanisms and preventive strategies remain to be investigated. The present study was designed to investigate the protective effect of naringin, a bioflavonoid, on gentamicin-induced nephrotoxicity and to elucidate the potential mechanism. Serum specific renal function parameters (blood urea nitrogen and creatinine) and histopathology of kidney tissues were evaluated to assess the gentamicin-induced nephrotoxicity. Renal oxidative stress (lipid peroxidation, protein carbonylation, enzymatic and non-enzymatic antioxidants), inflammatory (NF-kB [p65], TNF-α, IL-6 and MPO) and apoptotic (caspase 3, caspase 9, Bax, Bcl-2, p53 and DNA fragmentation) markers were also evaluated. Significant decrease in mitochondrial NADH dehydrogenase, succinate dehydrogenase, cytochrome c oxidase and mitochondrial redox activity indicated the gentamicin-induced mitochondrial dysfunction. Naringin (100 mg/kg) treatment along with gentamicin restored the mitochondrial function and increased the renal endogenous antioxidant status. Gentamicin induced increased renal inflammatory cytokines (TNF-α and IL-6), nuclear protein expression of NF-κB (p65) and NF-κB-DNA binding activity and myeloperoxidase (MPO) activity were significantly decreased upon naringin treatment. In addition, naringin treatment significantly decreased the amount of cleaved caspase 3, Bax, and p53 protein expression and increased the Bcl-2 protein expression. Naringin treatment also ameliorated the extent of histologic injury and reduced inflammatory infiltration in renal tubules. U-HPLS-MS data revealed that naringin co-administration along with gentamicin did not alter the renal uptake and/or accumulation of gentamicin in kidney tissues. These findings suggest that naringin treatment attenuates renal dysfunction and structural damage through the reduction of oxidative stress, mitochondrial dysfunction, inflammation and apoptosis in

  11. Low-level radiation waste management system

    International Nuclear Information System (INIS)

    Kubofcik, K.W.

    1990-01-01

    This patent describes a low-level radiation waste container set for use in conjunction with an open-topped receptacle. It comprises: a receptacle liner having a closed end and an open end, the receptacle liner sized for deployment as an inserted liner in an open-topped receptacle for collecting low-level radiation waste material within the receptacle liner within the open-topped receptacle; a cover sized and shaped to fit over the open top of the open-topped receptacle and the receptacle liner therein with the cover is in a closed position. The cover having a depending skirt which, when the cover is in the closed position, extends downwardly to overlap the open-topped receptacle adjacent the open top thereof and a portion of the receptacle liner received therein; and the receptacle liner and cover being fabricated of flexible radiation shielding material

  12. The STAR Level-3 trigger system

    International Nuclear Information System (INIS)

    Adler, C.; Berger, J.; Demello, M.; Dietel, T.; Flierl, D.; Landgraf, J.; Lange, J.S.; LeVine, M.J.; Ljubicic, A.; Nelson, J.; Roehrich, D.; Stock, R.; Struck, C.; Yepes, P.

    2003-01-01

    The STAR Level-3 trigger issues a trigger decision upon a complete online reconstruction of Au+Au collisions at relativistic heavy ion collider energies. Central interactions are processed up to a rate of 50 s -1 including a simple analysis of physics observables. The setup of the processor farm and the event reconstruction as well as experiences and the proposed trigger algorithms are described

  13. Effect of local hemostatics on bone induction in rats: a comparative study of bone wax, fibrin-collagen paste, and bioerodible polyorthoester with and without gentamicin

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Bang, G

    1992-01-01

    Local hemostatics for osseous tissue should preferably be absorbable and biocompatible and should not inhibit osteogenesis. The tissue response and effect on demineralized bone-induced heterotopic osteogenesis in the abdominal muscle of 120 male Wistar rats by different local hemostatics were...... evaluated by light microscopy and 85Sr uptake analyses. Non-absorbable bone wax of 88% beeswax and absorbable bovine fibrin-collagen paste both significantly inhibited osteoinduction, whereas a bioerodible polyorthoester drug delivery system with or without 4% gentamicin did not. Bone wax was not absorbed...

  14. Hydrostatic Water Level Systems At Homestake DUSEL

    Science.gov (United States)

    Stetler, L. D.; Volk, J. T.

    2009-12-01

    Two arrays of Fermilab-style hydrostatic water level sensors have been installed in the former Homestake gold mine in Lead, SD, the site of the new Deep Underground Science and Engineering Laboratory (DUSEL). Sensors were constructed at Fermilab from 8.5 cm diameter PVC pipe (housing) that was sealed on the ends and fit with a proximity sensor. The instrument have a height of 10 cm. Two ports in each sensor housing provide for connectivity, the upper port for air and the bottom port for water. Multiple instruments connected in series provide a precise water level and differences in readings between successive sensors provide for ground tilt to be resolved. Sensor resolution is 5 μm per count and has a range of approximately 1.25 cm. Data output from each sensor is relayed to a Fermilab-constructed readout card that also has temperature/relative humidity and barometric pressure sensors connected. All data are relayed out of the mine by fiber optic cable and can be recorded by Ethernet at remote locations. The current arrays have been installed on the 2000-ft level (610 m) and consist of six instruments in each array. Three sensors were placed in a N-S oriented drift and three in an E-W oriented drift. Using this orientation, it is anticipated that tilt direction may be resolved in addition to overall tilt magnitude. To date the data show passage of earth tides and frequency analysis has revealed five components to this signal, three associated with the semi-diurnal (~12.4 hr) and two with the diurnal (~24.9 hr) tides. Currently, installation methods are being analyzed between concrete pillar and rib-mounting using the existing setup on the 2000-ft level. Using these results, two additional arrays of Fermilab instruments will be installed on the 4550-ft and 4850-ft levels (1387 and 1478 m, respectively). In addition to Fermilab instruments, several high resolution Budker tiltmeters (1 μm resolution) will be installed in the mine workings in the near future, some

  15. Pavement Management Systems on a Local Level

    OpenAIRE

    Vasquez, Cristian A.

    2011-01-01

    Roads are one of the most valuable infrastructure assets within a community. Proper maintenance of the roadway network can promote the prosperity of a community. In recent times maintenance has become much more difficult with the price of asphalt increasing drastically and city budgets contracting due to the economic downturn. With these conditions, the proper management of an agency’s street network is necessary. The use of pavement management systems provides the help needed in the preserva...

  16. Multi-level RF identification system

    Science.gov (United States)

    Steele, Kerry D.; Anderson, Gordon A.; Gilbert, Ronald W.

    2004-07-20

    A radio frequency identification system having a radio frequency transceiver for generating a continuous wave RF interrogation signal that impinges upon an RF identification tag. An oscillation circuit in the RF identification tag modulates the interrogation signal with a subcarrier of a predetermined frequency and modulates the frequency-modulated signal back to the transmitting interrogator. The interrogator recovers and analyzes the subcarrier signal and determines its frequency. The interrogator generates an output indicative of the frequency of the subcarrier frequency, thereby identifying the responding RFID tag as one of a "class" of RFID tags configured to respond with a subcarrier signal of a predetermined frequency.

  17. Portable Water Level Monitoring System via SMS

    Directory of Open Access Journals (Sweden)

    Jomar S. Vitales

    2015-11-01

    Full Text Available Damages and lives taken by the typhoon Ondoy and other super typhoons brought the researchers to think and develop a device that warns people an hour or more than an hour before the devastating phenomena. In this project the researchers have thought of using text messaging in which the country’s leading means of communication. The development of the project was guided by the Engineering Design Cycle of Dr. Allan Cheville in his book entitled “Rocket Engineering”. The researchers have identified and used the needed materials which are suited in the intended function of the project. The project was already evaluated and had gathered a favorable response from the knowledgeable respondents in the field where the design project is intended to use. The project has a high acceptability level in the respondents’ point of view. The researchers are highly recommending the implementation of the project for a better testing in the incoming rainy season and also recommending to be placed in the Pantalan Bridge in Pantalan, Nasugbu, Batangas, Philippines. The researchers are also suggesting another study for a better water proof casing of the project.

  18. Tritium Labeled Gentamicin C: II.- Bioradiactive Degradation Products of Gentamicin by Catalytic H2O-3H Exchange Reaction; Getamicina C Tritiada: II.- Productos de Degradacion Radiactivos y Bioactivos en el Intercambio Catalitico con H2O-3H

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, C.; Diaz, A.; Paz, D.; Jimeno, M. L.

    1992-07-01

    The main bio radioactive degradation products from catalytic hydrogen exchange of gentamicin C, (C1 + C2 + Cla) in basic form, are generated by N-demethylation in 3{sup -}N and 6-N positions. Their structures were confirmed by 1HNMR and 13CNMR. These derivatives were fractionated by chromatography on silica gel. Antibacterial activities were similar to those of the parent antibiotics. Tritium exchange, under vacuum or nitrogen, is highly increased (4:1) when gentamicin are in basic form. In contrast with gentamicin sulfate, hydrolytic sub products as gramine, genta mines, garosamine and purpurosamines are practically absent. To properly optimize the exchange process, the composition of the gentamicin C complex must be taken into account. The exchange decreases in the order C2 > C1> Cla. Because of 6'-N-demethyl gentamicin C1 is C2, the radiochemical yield of C2 appears enhanced in the H2O-3H exchange of a mixture of them. Radioactivity distribution among the components and subunits of these three gentamicin were studied by strong and mild hydrolysis, and by methanolysis. (Author) 18 refs.

  19. Tritium Labeled Gentamicin C: II.- Bioradiactive Degradation Products of Gentamicin by Catalytic H2O-3H Exchange Reaction; Getamicina C Tritiada: II.- Productos de Degradacion Radiactivos y Bioactivos en el Intercambio Catalitico con H2O-3H

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, C; Diaz, A; Paz, D; Jimeno, M L

    1992-07-01

    The main bio radioactive degradation products from catalytic hydrogen exchange of gentamicin C, (C1 + C2 + Cla) in basic form, are generated by N-demethylation in 3{sup -}N and 6-N positions. Their structures were confirmed by 1HNMR and 13CNMR. These derivatives were fractionated by chromatography on silica gel. Antibacterial activities were similar to those of the parent antibiotics. Tritium exchange, under vacuum or nitrogen, is highly increased (4:1) when gentamicin are in basic form. In contrast with gentamicin sulfate, hydrolytic sub products as gramine, genta mines, garosamine and purpurosamines are practically absent. To properly optimize the exchange process, the composition of the gentamicin C complex must be taken into account. The exchange decreases in the order C2 > C1> Cla. Because of 6'-N-demethyl gentamicin C1 is C2, the radiochemical yield of C2 appears enhanced in the H2O-3H exchange of a mixture of them. Radioactivity distribution among the components and subunits of these three gentamicin were studied by strong and mild hydrolysis, and by methanolysis. (Author) 18 refs.

  20. Histological Evidence of Nephroprotective Effect of Ashwagandha (Withania somnifera Root Extract against Gentamicin Induced Nephrotoxicity in Rats

    Directory of Open Access Journals (Sweden)

    Sadia Choudhury Shimmi

    2014-01-01

    Full Text Available Background: Kidney damage can occur due to exposure to nephrotoxic drugs, chemicals, toxins and infectious agents, ultimately leading to renal failure, management of which is a great challenge. So, efforts have been focused on traditional and herbal medicines for the treatment of renal failure. Ashwagandha (Withania somnifera may have free radical scavenging activity and can be used for the prevention and treatment of kidney damage. Objective: To observe the histological evidence of nephroprotective effect of Ashwagandha root against gentamicin induced nephrotoxicity in rats. Materials and Methods: This study was done in the department of Physiology, Sir Salimullah Medical College, Dhaka. A total number of 31 male Wistar albino rats were acclimatized for 14 days. Then, these were divided into two groups, control group consisted of 18 rats (Group A and Ashwagandha pretreated and gentamicin-treated group consisted of 13 rats (Group B. Control group was again subdivided into baseline control and gentamicin-treated control groups (A1 and A2 ─ each group contained 9 rats. All the animals received basal diet for 22 consecutive days. In addition to this, animals of Group A2 received gentamicin subcutaneously (100 mg/kg body weight/day from 15th to 22nd day and animals of Group B received Ashwagandha root extract (500 mg/kg body weight/day orally for 22 consecutive days and gentamicin subcutaneously (100 mg/kg body weight/day from 15th to 22nd day. All the animals were sacrificed on 23rd day. Then kidney samples were collected and histology was done by using standard laboratory procedure. Results: Histological examination of kidney revealed abnormal histological findings in 100% of gentamicin-treated rats. But 92.31% of rats in Ashwagandha pretreated and gentamicin-treated group showed almost normal structure and 7.69% showed mild histological changes. Conclusion: Ashwagandha root may have some nephroprotective effect against gentamicin induced

  1. Gentamicin treatment in exercised mdx mice: Identification of dystrophin-sensitive pathways and evaluation of efficacy in work-loaded dystrophic muscle.

    Science.gov (United States)

    De Luca, Annamaria; Nico, Beatrice; Rolland, Jean-François; Cozzoli, Anna; Burdi, Rosa; Mangieri, Domenica; Giannuzzi, Viviana; Liantonio, Antonella; Cippone, Valentina; De Bellis, Michela; Nicchia, Grazia Paola; Camerino, Giulia Maria; Frigeri, Antonio; Svelto, Maria; Camerino, Diana Conte

    2008-11-01

    Aminoglycosides force read through of premature stop codon mutations and introduce new mutation-specific gene-corrective strategies in Duchenne muscular dystrophy. A chronic treatment with gentamicin (32 mg/kg/daily i.p., 8-12 weeks) was performed in exercised mdx mice with the dual aim to clarify the dependence on dystrophin of the functional, biochemical and histological alterations present in dystrophic muscle and to verify the long term efficiency of small molecule gene-corrective strategies in work-loaded dystrophic muscle. The treatment counteracted the exercise-induced impairment of in vivo forelimb strength after 6-8 weeks. We observed an increase in dystrophin expression level in all the fibers, although lower than that observed in normal fibers, and found a concomitant recovery of aquaporin-4 at sarcolemma. A significant reduction in centronucleated fibers, in the area of necrosis and in the percentage of nuclear factor-kB-positive nuclei was observed in gastrocnemious muscle of treated animals. Plasma creatine kinase was reduced by 70%. Ex vivo, gentamicin restored membrane ionic conductance in mdx diaphragm and limb muscle fibers. No effects were observed on the altered calcium homeostasis and sarcolemmal calcium permeability, detected by electrophysiological and microspectrofluorimetric approaches. Thus, the maintenance of a partial level of dystrophin is sufficient to reinforce sarcolemmal stability, reducing leakiness, inflammation and fiber damage, while correction of altered calcium homeostasis needs greater expression of dystrophin or direct interventions on the channels involved.

  2. Refractory episodic vertigo: role of intratympanic gentamicin and vestibular evoked myogenic potentials.

    Science.gov (United States)

    Celis-Aguilar, Erika; Hinojosa-González, Ramon; Vales-Hidalgo, Olivia; Coutinho-Toledo, Heloisa

    Even today, the treatment of intractable vertigo remains a challenge. Vestibular ablation with intratympanic gentamicin stands as a good alternative in the management of refractory vertigo patients. To control intractable vertigo through complete saccular and horizontal canal vestibular ablation with intratympanic gentamicin treatment. Patients with refractory episodic vertigo were included. The inclusion criteria were: unilateral ear disease, moderate to profound sensorineural hearing loss, and failure to other treatments. Included patients underwent 0.5-0.8mL of gentamicin intratympanic application at a 30mg/mL concentration. Vestibular ablation was confirmed by the absence of response on cervical vestibular evoked myogenic potentials and no response on caloric tests. Audiometry, electronystagmography with iced water, and vestibular evoked myogenic potentials were performed in all patients. Ten patients were included; nine patients with Meniere's disease and one patient with (late onset) delayed hydrops. Nine patients showed an absent response on vestibular evoked myogenic potentials and no response on caloric tests. The only patient with low amplitude on cervical vestibular evoked myogenic potentials had vertigo recurrence. Vertigo control was achieved in 90% of the patients. One patient developed hearing loss >30dB. Cervical vestibular evoked myogenic potentials confirmed vestibular ablation in patients treated with intratympanic gentamicin. High-grade vertigo control was due to complete saccular and horizontal canal ablation (no response to iced water in electronystagmography and no response on cervical vestibular evoked myogenic potentials). Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  3. Management of intractable Ménière's disease after intratympanic injection of gentamicin.

    Science.gov (United States)

    Rah, Yoon C; Han, Jae J; Park, Jaehong; Choi, Byung Y; Koo, Ja-Won

    2015-04-01

    1) To evaluate the efficacy of, and problems with, intratympanic gentamicin injection (ITG) in medically intractable definite Ménière's disease (MD) and secondary endolymphatic hydrops (EH); and 2) to review the vestibular status and treatment options of intractable vertigo even after ITG. Retrospective case review and survey. 780 patients with definite MD and secondary EH were enrolled. Long-term outcomes and problems of applied treatment options including ITG and exploratory tympanotomy and gentamicin application (ETG) were analyzed. Of the 780 patients, 95 patients received ITG. Class A and B control of vertigo was achieved in 85 (89.5%) patients; two patients were class C and eight patients were class F (ETG: 6; labyrinthectomy: 1; vestibular neurectomy: 1). Among seven patients who received ETG including 1 patient who skipped ITG due to chronic otitis media, five patients improved to class A, showing a 71.4% success rate; and labyrinthectomies were performed subsequently in the two remaining patients. Vertigo was controlled (class A) in all the patients who received labyrinthectomies (n = 4) or vestibular neurectomy (n = 1). Eight patients (8.4%) experienced more than 10 dB worsening, and two patients (2.1%) progressed to bilateral Ménière's disease. ITG failed to control vertigo in 10.5% of cases. ETG may be a reasonable option to facilitate the delivery of gentamicin into the inner ear by direct application of gentamicin over the round window and the oval window. Labyrinthectomy and vestibular neurectomy still have roles in the era of ITG. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Liquid hydrogen transfer pipes and level regulation systems

    International Nuclear Information System (INIS)

    Marquet, M.; Prugne, P.; Roubeau, P.

    1961-01-01

    Describes: 1) Transfer pipes - Plunging rods in liquid hydrogen Dewars; transfer pipes: knee-joint system for quick and accurate positioning of plunging Dewar rods; system's rods: combined valve and rod; valves are activated either by a bulb pressure or by a solenoid automatically or hand controlled. The latter allows intermittent filling. 2) Level regulating systems: Level bulbs: accurate to 1 or 4 m; maximum and minimum level bulbs: automatic control of the liquid hydrogen valve. (author) [fr

  5. A New Type of Biphasic Calcium Phosphate Cement as a Gentamicin Carrier for Osteomyelitis

    Directory of Open Access Journals (Sweden)

    Wen-Yu Su

    2013-01-01

    Full Text Available Osteomyelitis therapy is a long-term and inconvenient procedure for a patient. Antibiotic-loaded bone cements are both a complementary and alternative treatment option to intravenous antibiotic therapy for the treatment of osteomyelitis. In the current study, the biphasic calcium phosphate cement (CPC, called α-TCP/HAP (α-tricalcium phosphate/hydroxyapatite biphasic cement, was prepared as an antibiotics carrier for osteomyelitis. The developed biphasic cement with a microstructure of α-TCP surrounding the HAP has a fast setting time which will fulfill the clinical demand. The X-ray diffraction and Fourier transform infrared spectrometry analyses showed the final phase to be HAP, the basic bone mineral, after setting for a period of time. Scanning electron microscopy revealed a porous structure with particle sizes of a few micrometers. The addition of gentamicin in α-TCP/HAP would delay the transition of α-TCP but would not change the final-phase HAP. The gentamicin-loaded α-TCP/HAP supplies high doses of the antibiotic during the initial 24 hours when they are soaked in phosphate buffer solution (PBS. Thereafter, a slower drug release is produced, supplying minimum inhibitory concentration until the end of the experiment (30 days. Studies of growth inhibition of Staphylococcus aureus and Pseudomonas aeruginosa in culture indicated that gentamicin released after 30 days from α-TCP/HAP biphasic cement retained antibacterial activity.

  6. Effects of the antibiotics Gentamicin on the postembryonic development of Chrysomya putoria (Diptera: Calliphoridae).

    Science.gov (United States)

    Ferraz, Adriana C P; Dallavecchia, Daniele L; Silva, Débora C; Figueiredo, Adriana L; Proença, Barbara; Silva-Filho, Renato G; Aguiar, Valéria M

    2014-01-01

    We evaluate the effects the antibiotic Gentamicin on the development of Chrysomya putoria (Wiedemann, 1818). Third-generation, first-instar larvae were reared in a climatic chamber on 60 g of homogenate + agar 65% and were treated with three concentrations of Gentamicin: 4.44 mg/ml, 13.33 mg/ml, and 66.66 mg/ml. The control consisted of distilled water. The relationships between mean body mass of mature larvae (measured after diet abandonment, in batches of five individuals), duration of larval and pupal stages, and overall duration of development were analyzed. The actual sex ratio was compared against the expected using the chi square. None of the parameters measured differed significantly among the four treatments, with one exception: when Gentamicin concentration was 13.33 mg/ml, larval viability differed significantly from the control. All larvae from all treatments were considered normal. We conclude that the antibiotic did not significantly alter the development of C. putoria (Wiedemann) (Diptera: Calliphoridae). © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.

  7. Method of calibrating a fluid-level measurement system

    Science.gov (United States)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2010-01-01

    A method of calibrating a fluid-level measurement system is provided. A first response of the system is recorded when the system's sensor(s) is (are) not in contact with a fluid of interest. A second response of the system is recorded when the system's sensor(s) is (are) fully immersed in the fluid of interest. Using the first and second responses, a plurality of expected responses of the system's sensor(s) is (are) generated for a corresponding plurality of levels of immersion of the sensor(s) in the fluid of interest.

  8. Uncertainties in different level assessments of domestic ventilation systems

    NARCIS (Netherlands)

    Bokel, R.M.J.; Yang, Z.; Cauberg, J.J.M.

    2013-01-01

    In order to improve the quality of ventilation systems, assessments are widely used. In this paper, 3 main assessment levels are distinguished based on the number of ventilation systems to be assessed and the assessment objective. The main assessment levels distinguished in this paper are global

  9. Radar Based Flow and Water Level Forecasting in Sewer Systems

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Rasmussen, Michael R.; Grum, M.

    2009-01-01

    This paper describes the first radar based forecast of flow and/or water level in sewer systems in Denmark. The rainfall is successfully forecasted with a lead time of 1-2 hours, and flow/levels are forecasted an additional ½-1½ hours using models describing the behaviour of the sewer system. Bot...

  10. Release of Gentamicin and Vancomycin from Preformed Spacers in Infected Total Hip Arthroplasties: Measurement of Concentrations and Inhibitory Activity in Patients’ Drainage Fluids and Serum

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2013-01-01

    Full Text Available Gentamicin (G and vancomycin (V concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips were treated by implantation of industrial G-loaded spacers. Vancomycin was added by manually mixing with PMMA bone cement. Serum and drainage fluid samples were collected 1, 4, and 24 hours after spacer implantation. Antibiotics concentrations and drains bactericidal titer of combination were determined against multiresistant staphylococcal strains. The release of G and V from PMMA cement at the site of infection was prompt and effective. Serum levels were below the limit of detection. The local release kinetics of G and V from PMMA cement was similar, exerting a pronounced, combined inhibitory effect in the implant site. The inhibitory activity of drainage fluids showed substantial intersubject variability related to antibiotic concentrations and differed according to the pathogens tested. Gentamicin and vancomycin were released from temporary hip spacers at bactericidal concentrations, and their use in combination exerted strong inhibition against methicillin-resistant S. aureus and Coagulase Negative Staphylococci strains.

  11. System-Level Monitoring and Diagnosis of Building HVAC System

    OpenAIRE

    Wu, Siyu

    2013-01-01

    Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC system dominates the energy consumption and accounts for 57% of the energy used in U.S. commercial and residential buildings. Unfortunately, the HVAC system may fail to meet the performance expectations due to various faults, including not only complete hardware failures, but also non-optimal operations....

  12. Constraints on relaxation rates for N-level quantum systems

    International Nuclear Information System (INIS)

    Schirmer, S.G.; Solomon, A.I.

    2004-01-01

    We study the constraints imposed on the population and phase relaxation rates by the physical requirement of completely positive evolution for open N-level systems. The Lindblad operators that govern the evolution of the system are expressed in terms of observable relaxation rates, explicit formulas for the decoherence rates due to population relaxation are derived, and it is shown that there are additional, nontrivial constraints on the pure dephasing rates for N>2. Explicit, experimentally testable inequality constraints for the decoherence rates are derived for three- and four-level systems, and the implications of the results are discussed for generic ladder, Λ, and V systems and transitions between degenerate energy levels

  13. N-Level Quantum Systems and Legendre Functions

    OpenAIRE

    Mazurenko, A. S.; Savva, V. A.

    2001-01-01

    An excitation dynamics of new quantum systems of N equidistant energy levels in a monochromatic field has been investigated. To obtain exact analytical solutions of dynamic equations an analytical method based on orthogonal functions of a real argument has been proposed. Using the orthogonal Legendre functions we have found an exact analytical expression for a population probability amplitude of the level n. Various initial conditions for the excitation of N-level quantum systems have been co...

  14. Evaluation of Gentamicin-Entrapped Solid Lipid Microparticles ...

    African Journals Online (AJOL)

    microbial infections, is limited by poor absorption, low bioavailability ... engineering of lipid drug delivery systems. (LBDDS) ... based SLMs), these problems could be surmounted. ..... addition to the burst effect, may also be related to high rate ...

  15. Activity of Daptomycin Alone and in Combination with Rifampin and Gentamicin against Staphylococcus aureus Assessed by Time-Kill Methodology▿ †

    Science.gov (United States)

    Credito, Kim; Lin, Gengrong; Appelbaum, Peter C.

    2007-01-01

    The synergistic effects of daptomycin plus gentamicin or rifampin were tested against 50 Staphylococcus aureus strains, with daptomycin MICs ranging between 0.25 and 8 μg/ml. Daptomycin sub-MICs combined with gentamicin concentrations lower than the MIC yielded synergy in 34 (68%) of the 50 strains. Daptomycin combined with rifampin yielded synergy in one vancomycin-intermediate S. aureus strain only, and virtually all synergy occurred between daptomycin and gentamicin. PMID:17220402

  16. Effects of Kangshen Oral Liquid on Gentamicin-induced Acute ...

    African Journals Online (AJOL)

    1Department of Heart-Kidney Internal Medicine, 2Department of Vasculocardiology, 3Department of ... Results: After treatment with KSOL (20, 10, or 5 mL/kg), the RI, activity of NAG and levels of UP, SCr, .... Acetic acid was obtained .... had extreme edema, which resulted in stenosis .... Protective role of amino guanidine on.

  17. Optimal Multi-Level Lot Sizing for Requirements Planning Systems

    OpenAIRE

    Earle Steinberg; H. Albert Napier

    1980-01-01

    The wide spread use of advanced information systems such as Material Requirements Planning (MRP) has significantly altered the practice of dependent demand inventory management. Recent research has focused on development of multi-level lot sizing heuristics for such systems. In this paper, we develop an optimal procedure for the multi-period, multi-product, multi-level lot sizing problem by modeling the system as a constrained generalized network with fixed charge arcs and side constraints. T...

  18. Extracellular gentamicin reduces the activity of connexin hemichannels and interferes with purinergic Ca2+ signaling in HeLa cells

    Science.gov (United States)

    Figueroa, Vania A.; Retamal, Mauricio A.; Cea, Luis A.; Salas, José D.; Vargas, Aníbal A.; Verdugo, Christian A.; Jara, Oscar; Martínez, Agustín D.; Sáez, Juan C.

    2014-01-01

    Gap junction channels (GJCs) and hemichannels (HCs) are composed of protein subunits termed connexins (Cxs) and are permeable to ions and small molecules. In most organs, GJCs communicate the cytoplasm of adjacent cells, while HCs communicate the intra and extracellular compartments. In this way, both channel types coordinate physiological responses of cell communities. Cx mutations explain several genetic diseases, including about 50% of autosomal recessive non-syndromic hearing loss. However, the possible involvement of Cxs in the etiology of acquired hearing loss remains virtually unknown. Factors that induce post-lingual hearing loss are diverse, exposure to gentamicin an aminoglycoside antibiotic, being the most common. Gentamicin has been proposed to block GJCs, but its effect on HCs remains unknown. In this work, the effect of gentamicin on the functional state of HCs was studied and its effect on GJCs was reevaluated in HeLa cells stably transfected with Cxs. We focused on Cx26 because it is the main Cx expressed in the cochlea of mammals where it participates in purinergic signaling pathways. We found that gentamicin applied extracellularly reduces the activity of HCs, while dye transfer across GJCs was not affected. HCs were also blocked by streptomycin, another aminoglycoside antibiotic. Gentamicin also reduced the adenosine triphosphate release and the HC-dependent oscillations of cytosolic free-Ca2+ signal. Moreover, gentamicin drastically reduced the Cx26 HC-mediated membrane currents in Xenopus laevis oocytes. Therefore, the extracellular gentamicin-induced inhibition of Cx HCs may adversely affect autocrine and paracrine signaling, including the purinergic one, which might partially explain its ototoxic effects. PMID:25237294

  19. Design for testability and diagnosis at the system-level

    Science.gov (United States)

    Simpson, William R.; Sheppard, John W.

    1993-01-01

    The growing complexity of full-scale systems has surpassed the capabilities of most simulation software to provide detailed models or gate-level failure analyses. The process of system-level diagnosis approaches the fault-isolation problem in a manner that differs significantly from the traditional and exhaustive failure mode search. System-level diagnosis is based on a functional representation of the system. For example, one can exercise one portion of a radar algorithm (the Fast Fourier Transform (FFT) function) by injecting several standard input patterns and comparing the results to standardized output results. An anomalous output would point to one of several items (including the FFT circuit) without specifying the gate or failure mode. For system-level repair, identifying an anomalous chip is sufficient. We describe here an information theoretic and dependency modeling approach that discards much of the detailed physical knowledge about the system and analyzes its information flow and functional interrelationships. The approach relies on group and flow associations and, as such, is hierarchical. Its hierarchical nature allows the approach to be applicable to any level of complexity and to any repair level. This approach has been incorporated in a product called STAMP (System Testability and Maintenance Program) which was developed and refined through more than 10 years of field-level applications to complex system diagnosis. The results have been outstanding, even spectacular in some cases. In this paper we describe system-level testability, system-level diagnoses, and the STAMP analysis approach, as well as a few STAMP applications.

  20. Stationary states of two-level open quantum systems

    International Nuclear Information System (INIS)

    Gardas, Bartlomiej; Puchala, Zbigniew

    2011-01-01

    A problem of finding stationary states of open quantum systems is addressed. We focus our attention on a generic type of open system: a qubit coupled to its environment. We apply the theory of block operator matrices and find stationary states of two-level open quantum systems under certain conditions applied on both the qubit and the surrounding.

  1. System Thinking Skills at the Elementary School Level

    Science.gov (United States)

    Assaraf, Orit Ben-Zvi; Orion, Nir

    2010-01-01

    This study deals with the development of system thinking skills at the elementary school level. It addresses the question of whether elementary school students can deal with complex systems. The sample included 40 4th grade students from one school in a small town in Israel. The students studied an inquiry-based earth systems curriculum that…

  2. Multi-Level Formation of Complex Software Systems

    Directory of Open Access Journals (Sweden)

    Hui Li

    2016-05-01

    Full Text Available We present a multi-level formation model for complex software systems. The previous works extract the software systems to software networks for further studies, but usually investigate the software networks at the class level. In contrast to these works, our treatment of software systems as multi-level networks is more realistic. In particular, the software networks are organized by three levels of granularity, which represents the modularity and hierarchy in the formation process of real-world software systems. More importantly, simulations based on this model have generated more realistic structural properties of software networks, such as power-law, clustering and modularization. On the basis of this model, how the structure of software systems effects software design principles is then explored, and it could be helpful for understanding software evolution and software engineering practices.

  3. System-level Modeling of Wireless Integrated Sensor Networks

    DEFF Research Database (Denmark)

    Virk, Kashif M.; Hansen, Knud; Madsen, Jan

    2005-01-01

    Wireless integrated sensor networks have emerged as a promising infrastructure for a new generation of monitoring and tracking applications. In order to efficiently utilize the extremely limited resources of wireless sensor nodes, accurate modeling of the key aspects of wireless sensor networks...... is necessary so that system-level design decisions can be made about the hardware and the software (applications and real-time operating system) architecture of sensor nodes. In this paper, we present a SystemC-based abstract modeling framework that enables system-level modeling of sensor network behavior...... by modeling the applications, real-time operating system, sensors, processor, and radio transceiver at the sensor node level and environmental phenomena, including radio signal propagation, at the sensor network level. We demonstrate the potential of our modeling framework by simulating and analyzing a small...

  4. A nationwide low-level waste management system

    International Nuclear Information System (INIS)

    1985-01-01

    The National Governors' Association, in conjunction with the Department of Energy's National Low-Level Waste Management Program, invited various representatives of states, regions, and federal agencies to comment on their perceptions of what major features would constitute a nationwide low-level waste management system. Three meetings were conducted and this report summarizes results of those meetings. The Low-Level Radioactive Waste Policy Act of 1980 placed primary responsibility on the states for disposal of low-level waste. Although initial efforts of states have been directed toward establishing compacts, it is evident that a successful long term system requires significant cooperation and communication among states, regions, federal agencies, and Congress

  5. Macrophage-stimulating protein attenuates gentamicin-induced inflammation and apoptosis in human renal proximal tubular epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ko Eun [Department of Internal Medicine, Chonnam National University Medical School, Gwangju 501-757 (Korea, Republic of); Kim, Eun Young [Department of Physiology, Chonnam National University Medical School, Gwangju 501-757 (Korea, Republic of); Kim, Chang Seong; Choi, Joon Seok; Bae, Eun Hui; Ma, Seong Kwon [Department of Internal Medicine, Chonnam National University Medical School, Gwangju 501-757 (Korea, Republic of); Kim, Kyung Keun [Department of Pharmacology, Chonnam National University Medical School, Gwangju 501-757 (Korea, Republic of); Lee, Jong Un [Department of Physiology, Chonnam National University Medical School, Gwangju 501-757 (Korea, Republic of); Kim, Soo Wan, E-mail: skimw@chonnam.ac.kr [Department of Internal Medicine, Chonnam National University Medical School, Gwangju 501-757 (Korea, Republic of)

    2013-05-10

    Highlights: •MSP/RON system is activated in rat kidney damaged by gentamicin. •MSP inhibits GM-induced cellular apoptosis and inflammation in HK-2 cells. •MSP attenuates GM-induced activation of MAPKs and NF-κB pathways in HK-2 cells. -- Abstract: The present study aimed to investigate whether macrophage-stimulating protein (MSP) treatment attenuates renal apoptosis and inflammation in gentamicin (GM)-induced tubule injury and its underlying molecular mechanisms. To examine changes in MSP and its receptor, recepteur d’origine nantais (RON) in GM-induced nephropathy, rats were injected with GM for 7 days. Human renal proximal tubular epithelial (HK-2) cells were incubated with GM for 24 h in the presence of different concentrations of MSP and cell viability was measured by MTT assay. Apoptosis was determined by flow cytometry of cells stained with fluorescein isothiocyanate-conjugated annexin V protein and propidium iodide. Expression of Bcl-2, Bax, caspase-3, cyclooxygenase (COX)-2, inducible nitric oxide synthase (iNOS), nuclear factor-kappa B (NF-κB), IκB-α, and mitogen-activated protein kinases (MAPKs) was analyzed by semiquantitative immunoblotting. MSP and RON expression was significantly greater in GM-treated rats, than in untreated controls. GM-treatment reduced HK-2 cell viability, an effect that was counteracted by MSP. Flow cytometry and DAPI staining revealed GM-induced apoptosis was prevented by MSP. GM reduced expression of anti-apoptotic protein Bcl-2 and induced expression of Bax and cleaved caspase 3; these effects and GM-induced expression of COX-2 and iNOS were also attenuated by MSP. GM caused MSP-reversible induction of phospho-ERK, phospho-JNK, and phospho-p38. GM induced NF-κB activation and degradation of IκB-α; the increase in nuclear NF-κB was blocked by inhibitors of ERK, JNK, p-38, or MSP pretreatment. These findings suggest that MSP attenuates GM-induced inflammation and apoptosis by inhibition of the MAPKs

  6. Proposal for a level 0 calorimeter trigger system for LHCb

    CERN Document Server

    Bertin, A; Capponi, M; D'Antone, I; De Castro, S; Donà, R; Galli, D; Giacobbe, B; Marconi, U; Massa, I; Piccinini, M; Poli, M; Semprini-Cesari, N; Spighi, R; Vecchi, S; Villa, M; Vitale, A; Zoccoli, A; Zoccoli, Antonio

    1999-01-01

    In this note we present a complete system for the Level-0 LHCb calorimeter triggers. The system is derived from the electromagnetic calorimeter pre-trigger developed for the HERA-B experiment. The proposed system follows closely the Level-0 trigger algorithms presented in the LHCb Technical Proposal based on an electromagnetic and hadronic showers analysis performed on 3x3 calorimeter matrix. The general architecture presented is completely synchronous and quite flexible to allow adaptation to further improvements on the Level-0 trigger algorithms.

  7. DAEDALUS: System-Level Design Methodology for Streaming Multiprocessor Embedded Systems on Chips

    NARCIS (Netherlands)

    Stefanov, T.; Pimentel, A.; Nikolov, H.; Ha, S.; Teich, J.

    2017-01-01

    The complexity of modern embedded systems, which are increasingly based on heterogeneous multiprocessor system-on-chip (MPSoC) architectures, has led to the emergence of system-level design. To cope with this design complexity, system-level design aims at raising the abstraction level of the design

  8. A Distributed Approach to System-Level Prognostics

    Science.gov (United States)

    Daigle, Matthew J.; Bregon, Anibal; Roychoudhury, Indranil

    2012-01-01

    Prognostics, which deals with predicting remaining useful life of components, subsystems, and systems, is a key technology for systems health management that leads to improved safety and reliability with reduced costs. The prognostics problem is often approached from a component-centric view. However, in most cases, it is not specifically component lifetimes that are important, but, rather, the lifetimes of the systems in which these components reside. The system-level prognostics problem can be quite difficult due to the increased scale and scope of the prognostics problem and the relative Jack of scalability and efficiency of typical prognostics approaches. In order to address these is ues, we develop a distributed solution to the system-level prognostics problem, based on the concept of structural model decomposition. The system model is decomposed into independent submodels. Independent local prognostics subproblems are then formed based on these local submodels, resul ting in a scalable, efficient, and flexible distributed approach to the system-level prognostics problem. We provide a formulation of the system-level prognostics problem and demonstrate the approach on a four-wheeled rover simulation testbed. The results show that the system-level prognostics problem can be accurately and efficiently solved in a distributed fashion.

  9. The tracking of high level waste shipments-TRANSCOM system

    International Nuclear Information System (INIS)

    Johnson, P.E.; Joy, D.S.; Pope, R.B.

    1995-01-01

    The TRANSCOM (transportation tracking and communication) system is the U.S. Department of Energy's (DOE's) real-time system for tracking shipments of spent fuel, high-level wastes, and other high-visibility shipments of radioactive material. The TRANSCOM system has been operational since 1988. The system was used during FY1993 to track almost 100 shipments within the US.DOE complex, and it is accessed weekly by 10 to 20 users

  10. The tracking of high level waste shipments - TRANSCOM system

    International Nuclear Information System (INIS)

    Johnson, P.E.; Joy, D.S.; Pope, R.B.; Thomas, T.M.; Lester, P.B.

    1994-01-01

    The TRANSCOM (transportation tracking and communication) system is the US Department of Energy's (DOE's) real-time system for tracking shipments of spent fuel, high-level wastes, and other high-visibility shipments of radioactive material. The TRANSCOM system has been operational since 1988. The system was used during FY 1993 to track almost 100 shipments within the US DOE complex, and it is accessed weekly by 10 to 20 users

  11. Wireless Fluid-Level Measurement System Equips Boat Owners

    Science.gov (United States)

    2008-01-01

    While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.

  12. Mathematical model comparing of the multi-level economics systems

    Science.gov (United States)

    Brykalov, S. M.; Kryanev, A. V.

    2017-12-01

    The mathematical model (scheme) of a multi-level comparison of the economic system, characterized by the system of indices, is worked out. In the mathematical model of the multi-level comparison of the economic systems, the indicators of peer review and forecasting of the economic system under consideration can be used. The model can take into account the uncertainty in the estimated values of the parameters or expert estimations. The model uses the multi-criteria approach based on the Pareto solutions.

  13. Modeling and simulation of the agricultural sprayer boom leveling system

    KAUST Repository

    Sun, Jian

    2011-01-01

    According to the agricultural precision requirements, the distance from sprayer nozzles to the corps should be kept between 50 cm to 70 cm. The sprayer boom also needs to be kept parallel to the field during the application process. Thus we can guarantee the quality of the chemical droplets distribution on the crops. In this paper we design a sprayer boom leveling system for agricultural sprayer vehicles combined with a four-rod linkage self-leveling suspension and electro-hydraulic auto-leveling system. The dynamic analysis shows that the suspension can realize an excellent self-leveling in a comparative small inclination range. In addition we build compensation controller for the electro-hydraulic system based on the mathematical model. With simulations we can optimize the performance of this controller to make sure a fast leveling response to the inclined sprayer boom. © 2011 IEEE.

  14. Experimental Hamiltonian identification for controlled two-level systems

    International Nuclear Information System (INIS)

    Schirmer, S.G.; Kolli, A.; Oi, D.K.L.

    2004-01-01

    We present a strategy to empirically determine the internal and control Hamiltonians for an unknown two-level system (black box) subject to various (piecewise constant) control fields when direct readout by measurement is limited to a single, fixed observable

  15. Modifying scoring system at South African University rugby level ...

    African Journals Online (AJOL)

    Success in rugby is measured by winning the game and in order to do so, teams need to score more points ... if modifying the scoring system at South African University rugby level changes the game dynamics. ... AJOL African Journals Online.

  16. Gentamicin-Eluting Titanium Dioxide Nanotubes Grown on the Ultrafine-Grained Titanium.

    Science.gov (United States)

    Nemati, Sima Hashemi; Hadjizadeh, Afra

    2017-08-01

    Titanium (Ti)-based materials is the most appropriate choices for the applications as orthopedic and dental implants. In this regard, ultrafine-grained (UFG) titanium with an enhanced mechanical properties and surface energy has attracted more attention. Titanium dioxide (TiO 2 ) nanotubes grown on the titanium could enhance bone bonding, cellular response and are good reservoirs for loading drugs and antibacterial agents. This article investigates gentamicin loading into and release from the TiO 2 nanotubes, grown on the UFG compared to coarse-grained (CG) titanium substrate surfaces. Equal Channel Angular Pressing (ECAP) was employed to produce the UFG structure titanium. TiO 2 nanotubes were grown by the anodizing technique on both UFG and CG titanium substrate surfaces. Scanning electron microscopy (SEM) imaging confirmed TiO 2 nanotube growth on the surface. The UV-vis spectroscopy analysis results show that the amount of gentamicin load-release in the anodized UFG titanium sample is higher than that of CG one which can be explained in terms of thicker TiO 2 nanotube arrays layer formed on UFG sample. Moreover, the anodized UFG titanium samples released the drug in a longer time than CG (1 day for the UFG titanium vs. 3 h for the CG one). Regarding wettability analysis, anodized UFG titanium sample showed more enhanced hydrophilicity than CG counterpart. Therefore, the significantly smaller grain size of pure titanium provided by the ECAP technique coupled with appropriate subsequent anodization treatment not only offers a good combination of biocompatibility and adequate mechanical properties but also it provides a delayed release condition for gentamicin.

  17. The upper level of control system of electron accelerators

    International Nuclear Information System (INIS)

    Gribov, I.V.; Nedeoglo, F.N.; Shvedunov, I.V.

    2005-01-01

    The upper level software of a three-level control system that supports several electron accelerators is described. This software operates in the Linux and RTLinux (Real Time Linux) environment. The object information model functions on the basis of a parametric description supported by the SQLite Data Base Management System. The Javascript sublanguage is used for script forming, and the Qt Designer application is used to construct the user interface [ru

  18. Multi-level predictive maintenance for multi-component systems

    International Nuclear Information System (INIS)

    Nguyen, Kim-Anh; Do, Phuc; Grall, Antoine

    2015-01-01

    In this paper, a novel predictive maintenance policy with multi-level decision-making is proposed for multi-component system with complex structure. The main idea is to propose a decision-making process considered on two levels: system level and component one. The goal of the decision rules at the system level is to address if preventive maintenance actions are needed regarding the predictive reliability of the system. At component level the decision rules aim at identifying optimally a group of several components to be preventively maintained when preventive maintenance is trigged due to the system level decision. Selecting optimal components is based on a cost-based group improvement factor taking into account the predictive reliability of the components, the economic dependencies as well as the location of the components in the system. Moreover, a cost model is developed to find the optimal maintenance decision variables. A 14-component system is finally introduced to illustrate the use and the performance of the proposed predictive maintenance policy. Different sensitivity analysis are also investigated and discussed. Indeed, the proposed policy provides more flexibility in maintenance decision-making for complex structure systems, hence leading to significant profits in terms of maintenance cost when compared with existing policies. - Highlights: • A predictive maintenance policy for complex structure systems is proposed. • Multi-level decision process based on prognostic results is proposed. • A cost-based group importance measure is introduced for decision-making. • Both positive and negative dependencies between components are investigated. • A cost model and Monte Carlo simulation are developed for optimization process.

  19. LevelScheme: A level scheme drawing and scientific figure preparation system for Mathematica

    Science.gov (United States)

    Caprio, M. A.

    2005-09-01

    LevelScheme is a scientific figure preparation system for Mathematica. The main emphasis is upon the construction of level schemes, or level energy diagrams, as used in nuclear, atomic, molecular, and hadronic physics. LevelScheme also provides a general infrastructure for the preparation of publication-quality figures, including support for multipanel and inset plotting, customizable tick mark generation, and various drawing and labeling tasks. Coupled with Mathematica's plotting functions and powerful programming language, LevelScheme provides a flexible system for the creation of figures combining diagrams, mathematical plots, and data plots. Program summaryTitle of program:LevelScheme Catalogue identifier:ADVZ Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADVZ Operating systems:Any which supports Mathematica; tested under Microsoft Windows XP, Macintosh OS X, and Linux Programming language used:Mathematica 4 Number of bytes in distributed program, including test and documentation:3 051 807 Distribution format:tar.gz Nature of problem:Creation of level scheme diagrams. Creation of publication-quality multipart figures incorporating diagrams and plots. Method of solution:A set of Mathematica packages has been developed, providing a library of level scheme drawing objects, tools for figure construction and labeling, and control code for producing the graphics.

  20. Microcontroller based multi-channel ultrasonic level monitoring system

    International Nuclear Information System (INIS)

    Ambastha, K.P.; Chaudhari, Y.V.; Singh, Inder Jeet; Chadda, V.K.

    2004-01-01

    Microcontroller based Multi-channel Ultrasonic Level Monitoring System developed by Computer Division is based on echo ranging techniques to monitor level. The transmitter directs an ultrasonic burst towards the liquid, which gets reflected from the top of the liquid surface. The time taken for ultrasound to travel from the transmitter to the top of liquid surface is measured and used to calculate the liquid level. The system provides for temperature compensation for accurate measurement as the ultrasound velocity depends on the ambient temperature. It can measure liquid level up to 5 meters. A single monitor can be used to measure level in 6 tanks. PC connectivity has been provided via RS 232 and RS 485 for remote operation and data logging of level. A GUI program developed using LABVIEW package displays level on PC monitor. The program provides for pictorial as well as numerical display for level and temperature in the front panel on the PC monitor. A user can monitor level for any or all tanks from the PC. One unit is installed at CIRUS for measuring level in Acid/ Alkali tanks and one is installed at APSARA for measuring water level in the reactor pool. (author)

  1. National high-level waste systems analysis report

    Energy Technology Data Exchange (ETDEWEB)

    Kristofferson, K.; Oholleran, T.P.; Powell, R.H.

    1995-09-01

    This report documents the assessment of budgetary impacts, constraints, and repository availability on the storage and treatment of high-level waste and on both existing and pending negotiated milestones. The impacts of the availabilities of various treatment systems on schedule and throughput at four Department of Energy sites are compared to repository readiness in order to determine the prudent application of resources. The information modeled for each of these sites is integrated with a single national model. The report suggests a high-level-waste model that offers a national perspective on all high-level waste treatment and storage systems managed by the Department of Energy.

  2. National high-level waste systems analysis report

    International Nuclear Information System (INIS)

    Kristofferson, K.; Oholleran, T.P.; Powell, R.H.

    1995-09-01

    This report documents the assessment of budgetary impacts, constraints, and repository availability on the storage and treatment of high-level waste and on both existing and pending negotiated milestones. The impacts of the availabilities of various treatment systems on schedule and throughput at four Department of Energy sites are compared to repository readiness in order to determine the prudent application of resources. The information modeled for each of these sites is integrated with a single national model. The report suggests a high-level-waste model that offers a national perspective on all high-level waste treatment and storage systems managed by the Department of Energy

  3. The ATLAS Data Acquisition and High Level Trigger system

    International Nuclear Information System (INIS)

    2016-01-01

    This paper describes the data acquisition and high level trigger system of the ATLAS experiment at the Large Hadron Collider at CERN, as deployed during Run 1. Data flow as well as control, configuration and monitoring aspects are addressed. An overview of the functionality of the system and of its performance is presented and design choices are discussed.

  4. Establishing a national safeguards system at the State level

    International Nuclear Information System (INIS)

    Lopez Lizana, Fernando

    2001-01-01

    This paper is the guide to a workshop designed to enable the participants to gain a better understanding of National Safeguards Systems and their functions. The workshop provides an opportunity to address the requirements for the organization that has to carry out the system functions at the State level in a country having a research reactor and ancillary laboratories

  5. System Specification for Immobilized High-Level Waste Interim Storage

    International Nuclear Information System (INIS)

    CALMUS, R.B.

    2000-01-01

    This specification establishes the system-level functional, performance, design, interface, and test requirements for Phase 1 of the IHLW Interim Storage System, located at the Hanford Site in Washington State. The IHLW canisters will be produced at the Hanford Site by a Selected DOE contractor. Subsequent to storage the canisters will be shipped to a federal geologic repository

  6. Entry Level Systems Analysts: What Does the Industry Want?

    Directory of Open Access Journals (Sweden)

    Donna M. Grant

    2016-06-01

    Full Text Available This study investigates the skill sets necessary for entry level systems analysts. Towards this end, the study combines two sources of data, namely, a content analysis of 200 systems analysts’ online job advertisements and a survey of 20 senior Information Systems (IS professionals. Based on Chi-square tests, the results reveal that most employers prefer entry level systems analysts with an undergraduate Computer Science degree. Furthermore, most of the employers prefer entry level systems analysts to have some years of experience as well as industry certifications. The results also reveal that there is a higher preference for entry level systems analysts who have non-technical and people skills (e.g., problem solving and oral communication. The empirical results from this study will inform IS educators as they develop future systems analysts. Additionally, the results will be useful to the aspiring systems analysts who need to make sure that they have the necessary job skills before graduating and entering the labor market.

  7. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  8. Measuring healthcare productivity - from unit to system level.

    Science.gov (United States)

    Kämäräinen, Vesa Johannes; Peltokorpi, Antti; Torkki, Paulus; Tallbacka, Kaj

    2016-04-18

    Purpose - Healthcare productivity is a growing issue in most Western countries where healthcare expenditure is rapidly increasing. Therefore, accurate productivity metrics are essential to avoid sub-optimization within a healthcare system. The purpose of this paper is to focus on healthcare production system productivity measurement. Design/methodology/approach - Traditionally, healthcare productivity has been studied and measured independently at the unit, organization and system level. Suggesting that productivity measurement should be done in different levels, while simultaneously linking productivity measurement to incentives, this study presents the challenges of productivity measurement at the different levels. The study introduces different methods to measure productivity in healthcare. In addition, it provides background information on the methods used to measure productivity and the parameters used in these methods. A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical information for managers. Findings - The study introduces different approaches and methods to measure productivity in healthcare. Practical implications - A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical benefits for managers. Originality/value - The authors focus on the measurement of the whole healthcare production system and try to avoid sub-optimization. Additionally considering an individual patient approach, productivity measurement is examined at the unit level, the organizational level and the system level.

  9. Elevated systemic galectin-1 levels characterize HELLP syndrome.

    Science.gov (United States)

    Schnabel, Annegret; Blois, Sandra M; Meint, Peter; Freitag, Nancy; Ernst, Wolfgang; Barrientos, Gabriela; Conrad, Melanie L; Rose, Matthias; Seelbach-Göbel, Birgit

    2016-04-01

    Galectin-1 (gal-1), a member of a family of conserved β-galactoside-binding proteins, has been shown to exert a key role during gestation. Though gal-1 is expressed at higher levels in the placenta from HELLP patients, it is still poorly understood whether systemic gal-1 levels also differ in HELLP patients. In the present study, we evaluated the systemic expression of gal-1, together with the angiogenic factors, placental growth factor (PlGF) and soluble fms-like tyrosine kinase 1 (sFlt-1) in conjunction with HELLP syndrome severity. Systemic levels of gal-1 and sFlt-1 were elevated in patients with both early- and late-onset HELLP syndrome as compared to healthy controls. In contrast, peripheral PlGF levels were decreased in early- and late-onset HELLP. A positive correlation between systemic gal-1 levels and sFlt-1/PlGF ratios was found in early onset HELLP patients. Our results show that HELLP syndrome is associated with increased circulating levels of gal-1; integrating systemic gal-1 measurements into the diagnostic analyses of pregnant women may provide more effective prediction of HELLP syndrome development. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Beyond different levels: embodiment and the developmental system.

    Science.gov (United States)

    Marshall, Peter J

    2014-01-01

    The value of studying a phenomenon at multiple levels of analysis is often emphasized in psychology, but a lack of clarity about the nature of levels and the relations among them remains an impediment to progress. The suggestion here is that an approach combining the tenets of embodiment with the construct of the developmental system provides a way forward. Embodiment opposes the splitting off and elevation of a level of mechanisms that has characterized much of cognitive science. In contrast, a constructivist embodied approach places a level of mechanisms in the context of a formal or systems level of analysis, with developmental process framing the interpenetrating relations between levels. Such an approach stems from a relational worldview that opposes conceptual splits and posits that levels of structure and process comprise an indissociable complementarity. The combination of embodiment and developmental systems within a relational worldview is discussed and elaborated through outlining the integrative approach of relational developmental systems, which has been proposed as a scientific paradigm within which formulations of the interrelations among brain, body, and mind can be advanced.

  11. Reliability review of the LHC collimators low level control system

    International Nuclear Information System (INIS)

    Masi, A.; Donze, M.; Losito, R.

    2011-01-01

    The LHC collimators' low level control system is responsible for the positioning, with an accuracy of a few um, of more than 500 motor axes located around the entire LHC tunnel and synchronized at us level,The collimators' axes position is verified in Real Time, monitoring at 100 Hz more than 700 LVDT positioning sensors. Apart from the challenging requirements of timing and positioning accuracy, the system is characterized by a high level of reliability since the collimators have the crucial function of machine protection. In this paper we focus on the architectural and technical choices adopted to guarantee the level of reliability required by the application. We also present the tools and solutions developed to manage this huge control system making the support easier and faster for its operation. (authors)

  12. High-level trigger system for the LHC ALICE experiment

    CERN Document Server

    Bramm, R; Lien, J A; Lindenstruth, V; Loizides, C; Röhrich, D; Skaali, B; Steinbeck, T M; Stock, Reinhard; Ullaland, K; Vestbø, A S; Wiebalck, A

    2003-01-01

    The central detectors of the ALICE experiment at LHC will produce a data size of up to 75 MB/event at an event rate less than approximately equals 200 Hz resulting in a data rate of similar to 15 GB/s. Online processing of the data is necessary in order to select interesting (sub)events ("High Level Trigger"), or to compress data efficiently by modeling techniques. Processing this data requires a massive parallel computing system (High Level Trigger System). The system will consist of a farm of clustered SMP-nodes based on off- the-shelf PCs connected with a high bandwidth low latency network.

  13. Mirror distortion of the levels of a compound system

    International Nuclear Information System (INIS)

    Khvalchenko, I.I.

    1995-01-01

    The problem of the action of an arbitrary perturbation on a system of two identical atoms in the radiation field is analyzed. For simplicity, only two-level atoms are considered, the field is assumed to be classical, and the spontaneous transitions are ignored. The polarizations are calculated for the open-quotes two atoms + fieldclose quotes and open-quotes two atoms + field + particleclose quotes systems. A comparison of the obtained relationships allows us to clarify the character of the level distortions caused by the external perturbation in the compound system. 10 refs

  14. System-Level Design Methodologies for Networked Multiprocessor Systems-on-Chip

    DEFF Research Database (Denmark)

    Virk, Kashif Munir

    2008-01-01

    is the first such attempt in the published literature. The second part of the thesis deals with the issues related to the development of system-level design methodologies for networked multiprocessor systems-on-chip at various levels of design abstraction with special focus on the modeling and design...... at the system-level. The multiprocessor modeling framework is then extended to include models of networked multiprocessor systems-on-chip which is then employed to model wireless sensor networks both at the sensor node level as well as the wireless network level. In the third and the final part, the thesis...... to the transaction-level model. The thesis, as a whole makes contributions by describing a design methodology for networked multiprocessor embedded systems at three layers of abstraction from system-level through transaction-level to the cycle accurate level as well as demonstrating it practically by implementing...

  15. Antibacterial efficacy of core-shell nanostructures encapsulating gentamicin against an in vivo intracellular  Salmonella model

    Directory of Open Access Journals (Sweden)

    Ashish Ranjan

    2009-12-01

    Full Text Available Ashish Ranjan1, Nikorn Pothayee2,3, Mohammed N Seleem2, Ronald D Tyler Jr4, Bonnie Brenseke4, Nammalwar Sriranganathan2,4, Judy S Riffle2,3, Ramanathan Kasimanickam11Department of Large Animal Clinical Sciences, 2Institute for Critical Technology and Applied Science, 3Macromolecules and Interfaces Institute, 4Department of Biomedical Sciences and Pathobiology, Virginia Polytechnic Institute and State University, Blacksburg, VAAbstract: Pluronic based core-shell nanostructures encapsulating gentamicin were designed in this study. Block copolymers of (PAA–+Na-b-(PEO-b-PPO-b-PEO-b-PAA– +Na were blended with PAA– Na+ and complexed with the polycationic antibiotic gentamicin to form nanostructures. Synthesized nanostructures had a hydrodynamic diameter of 210 nm, zeta potentials of –0.7 (±0.2, and incorporated ~20% by weight of gentamicin. Nanostructures upon co-incubation with J774A.1 macrophage cells showed no adverse toxicity in vitro. Nanostructures administered in vivo either at multiple dosage of 5 µg g–1 or single dosage of 15 µg g–1 in AJ-646 mice infected with Salmonella resulted in significant reduction of viable bacteria in the liver and spleen. Histopathological evaluation for concentration-dependent toxicity at a dosage of 15 µg g–1 revealed mineralized deposits in 50% kidney tissues of free gentamicin-treated mice which in contrast was absent in nanostructure-treated mice. Thus, encapsulation of gentamicin in nanostructures may reduce toxicity and improve in vivo bacterial clearance.Keywords: gentamicin, core-shell nanostructures, Salmonella

  16. Tissue reactions to bacteria-inoculated rat lead samples .2. Effect of local gentamicin release through surface-modified polyurethane tubing

    NARCIS (Netherlands)

    vanWachem, PB; vanLuyn, MJA; deWit, AW; Raatjes, D; Hendriks, M; Verhoeven, MLPM; Cahalan, PT

    A surface modification technique was developed to achieve controlled release of gentamicin from implanted polyurethane (PU) rat lead samples. PU tubing first was provided with an acrylic acid/acrylamide copolymer surface graft and then loaded with gentamicin. This surface modification technique

  17. Measurement of total phospholipids in urine of patients treated with gentamicin.

    Science.gov (United States)

    Saunders, D A; Begg, E J; Kirkpatrick, C M; Yeo, J; Graham, G G; Bailey, R R

    1997-04-01

    The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P < 0.0001). There was a negative linear relationship between phospholipid excretion and creatinine clearance (r2 = 0.71). In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P < 0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P < 0.03). These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.

  18. Formulation optimization of gentamicin loaded Eudragit RS100 microspheres using factorial design study.

    Science.gov (United States)

    Singh, Deependra; Saraf, Swarnlata; Dixit, Vinod Kumar; Saraf, Shailendra

    2008-04-01

    Gentamicin-Eudragit RS100 microspheres were prepared by modified double emulsion method. A 3(2) full factorial experiment was designed to study the effects of the composition of outer aqueous phase in terms of amount of glycerol (viscosity effect) and sodium chloride (osmotic pressure gradient effect) on the entrapment efficiency and % yield and microsphere size. The results of analysis of variance test for responses measured indicated that the test is significant (p>0.05). The contribution of sodium chloride concentration was found to be higher on entrapment efficiency and % yield, whereas glycerol produced significant effect on the mean diameter of microspheres. Microspheres demonstrated spherical particles in the size range of 33.24-60.43 microm. In vitro release profile of optimized formulation demonstrated sustained release for 24 h following Higuchi kinetics. Finally, drug bioactivity was found to remain intact after microencapsulation. Response surface graphs are presented to examine the effects of independent variables on the responses studied. Thus, by formulation design important parameters affecting formulation characteristics of gentamicin loaded Eudragit RS100 microspheres can be identified for controlled delivery with desirable characters in terms of maximum entrapment and yield.

  19. Multi-level and hybrid modelling approaches for systems biology.

    Science.gov (United States)

    Bardini, R; Politano, G; Benso, A; Di Carlo, S

    2017-01-01

    During the last decades, high-throughput techniques allowed for the extraction of a huge amount of data from biological systems, unveiling more of their underling complexity. Biological systems encompass a wide range of space and time scales, functioning according to flexible hierarchies of mechanisms making an intertwined and dynamic interplay of regulations. This becomes particularly evident in processes such as ontogenesis, where regulative assets change according to process context and timing, making structural phenotype and architectural complexities emerge from a single cell, through local interactions. The information collected from biological systems are naturally organized according to the functional levels composing the system itself. In systems biology, biological information often comes from overlapping but different scientific domains, each one having its own way of representing phenomena under study. That is, the different parts of the system to be modelled may be described with different formalisms. For a model to have improved accuracy and capability for making a good knowledge base, it is good to comprise different system levels, suitably handling the relative formalisms. Models which are both multi-level and hybrid satisfy both these requirements, making a very useful tool in computational systems biology. This paper reviews some of the main contributions in this field.

  20. Sea Level Forecasts Aggregated from Established Operational Systems

    Directory of Open Access Journals (Sweden)

    Andy Taylor

    2017-08-01

    Full Text Available A system for providing routine seven-day forecasts of sea level observable at tide gauge locations is described and evaluated. Forecast time series are aggregated from well-established operational systems of the Australian Bureau of Meteorology; although following some adjustments these systems are only quasi-complimentary. Target applications are routine coastal decision processes under non-extreme conditions. The configuration aims to be relatively robust to operational realities such as version upgrades, data gaps and metadata ambiguities. Forecast skill is evaluated against hourly tide gauge observations. Characteristics of the bias correction term are demonstrated to be primarily static in time, with time varying signals showing regional coherence. This simple approach to exploiting existing complex systems can offer valuable levels of skill at a range of Australian locations. The prospect of interpolation between observation sites and exploitation of lagged-ensemble uncertainty estimates could be meaningfully pursued. Skill characteristics define a benchmark against which new operational sea level forecasting systems can be measured. More generally, an aggregation approach may prove to be optimal for routine sea level forecast services given the physically inhomogeneous processes involved and ability to incorporate ongoing improvements and extensions of source systems.

  1. Gentamicin Injection

    Science.gov (United States)

    ... WARNING section and any of the following: other antibiotics such as amoxicillin (Amoxil, Larotid, Moxatag, in Augmentin, in Prevpac), ampicillin, or penicillin; dimenhydrate (Dramamine); meclizine (Bonine); or nonsteroidal anti-inflammatory drugs such as indomethacin (Indocin, Tivorbex). Your doctor ...

  2. Low Level RF Control System of J-PARC Synchrotrons

    CERN Document Server

    Tamura, Fumihiko; Ezura, Eizi; Hara, Keigo; Nomura, Masahiro; Ohmori, Chihiro; Schnase, Alexander; Takagi, Akira; Yamamoto, Masanobu; Yoshii, Masahito

    2005-01-01

    We present the concept and the design of the low level RF (LLRF) control system of the J-PARC synchrotrons. The J-PARC synchrotrons are the rapid cycling 3-GeV synchrotron (RCS) and the 50-GeV main ring (MR) which require very precise and stable LLRF control systems to accelerate the ultra-high proton beam current. The LLRF system of the synchrotron is a full-digital system based on the direct digital synthesis (DDS). The functions of the system are (1) the multi-harmonic RF generation for the acceleration and the longitudinal bunch shaping, (2) the feedbacks for stabilizing the beam, (3) the feedforward for compensating the heavy beam loading, and (4) other miscellaneous functions such as the synchronization and chopper timing. The LLRF system of the RCS is now under construction. We present the details of the system. Also, we show preliminary results of performance tests of the control modules.

  3. Alpha low-level stored waste systems design study

    Energy Technology Data Exchange (ETDEWEB)

    Feizollahi, F.; Teheranian, B. (Morrison Knudson Corp., San Francisco, CA (United States). Environmental Services Div.); Quapp, W.J. (EG and G Idaho, Inc., Idaho Falls, ID (United States))

    1992-08-01

    The Stored Waste System Design Study (SWSDS), commissioned by the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examines relative life-cycle costs associated with three system concepts for processing the alpha low-level waste (alpha-LLW) stored at the Radioactive Waste Management Complex's Transuranic Storage Area at the INEL. The three system concepts are incineration/melting; thermal treatment/solidification; and sort, treat, and repackage. The SWSDS identifies system functional and operational requirements and assesses implementability; effectiveness; cost; and demonstration, testing, and evaluation (DT E) requirements for each of the three concepts.

  4. Alpha low-level stored waste systems design study

    Energy Technology Data Exchange (ETDEWEB)

    Feizollahi, F.; Teheranian, B. [Morrison Knudson Corp., San Francisco, CA (United States). Environmental Services Div.; Quapp, W.J. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1992-08-01

    The Stored Waste System Design Study (SWSDS), commissioned by the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examines relative life-cycle costs associated with three system concepts for processing the alpha low-level waste (alpha-LLW) stored at the Radioactive Waste Management Complex`s Transuranic Storage Area at the INEL. The three system concepts are incineration/melting; thermal treatment/solidification; and sort, treat, and repackage. The SWSDS identifies system functional and operational requirements and assesses implementability; effectiveness; cost; and demonstration, testing, and evaluation (DT&E) requirements for each of the three concepts.

  5. Alpha low-level stored waste systems design study

    International Nuclear Information System (INIS)

    Feizollahi, F.; Teheranian, B.

    1992-08-01

    The Stored Waste System Design Study (SWSDS), commissioned by the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examines relative life-cycle costs associated with three system concepts for processing the alpha low-level waste (alpha-LLW) stored at the Radioactive Waste Management Complex's Transuranic Storage Area at the INEL. The three system concepts are incineration/melting; thermal treatment/solidification; and sort, treat, and repackage. The SWSDS identifies system functional and operational requirements and assesses implementability; effectiveness; cost; and demonstration, testing, and evaluation (DT ampersand E) requirements for each of the three concepts

  6. The geometric phase in two-level atomic systems

    International Nuclear Information System (INIS)

    Tian Mingzhen; Barber, Zeb W.; Fischer, Joe A.; Randall Babbitt, Wm.

    2004-01-01

    We report the observation of the geometric phase in a closed two-level atomic system using stimulated photon echoes. The two-level system studied consists of the two-electronic energy levels ( 3 H 4 and 3 H 6 ) of Tm 3+ doped in YAG crystal. When a two-level atom at an arbitrary superposition state is excited by a pair of specially designed laser pulses, the excited state component gains a relative phase with respect to the ground state component. We identified the phase shift to be of pure geometric nature. The dynamic phase associated to the driving Hamiltonian is unchanged. The experiment results of the phase change agree with the theory to the extent of the measurement limit

  7. Commissioning the ATLAS Level-1 Central Trigger System

    CERN Document Server

    Sherman, Daniel

    2010-01-01

    The ATLAS Level-1 central trigger is a critical part of ATLAS operation. It receives the 40 MHz bunch clock from the LHC and distributes it to all sub-detectors. It initiates their read-out by forming the Level-1 Accept decision, which is based on information from the calorimeter and muon trigger processors and a variety of additional trigger inputs from detectors in the forward region. It also provides trigger summary information to the data acquisition system and the Level-2 trigger system. In this paper, we present the completion of the installed central trigger system, its performance during cosmic-ray data taking and the experience gained with triggering on the first LHC beams.

  8. Interconnection test framework for the CMS level-1 trigger system

    International Nuclear Information System (INIS)

    Hammer, J.; Magrans de Abril, M.; Wulz, C.E.

    2012-01-01

    The Level-1 Trigger Control and Monitoring System is a software package designed to configure, monitor and test the Level-1 Trigger System of the Compact Muon Solenoid (CMS) experiment at CERN's Large Hadron Collider. It is a large and distributed system that runs over 50 PCs and controls about 200 hardware units. The objective of this paper is to describe and evaluate the architecture of a distributed testing framework - the Interconnection Test Framework (ITF). This generic and highly flexible framework for creating and executing hardware tests within the Level-1 Trigger environment is meant to automate testing of the 13 major subsystems interconnected with more than 1000 links. Features include a web interface to create and execute tests, modeling using finite state machines, dependency management, automatic configuration, and loops. Furthermore, the ITF will replace the existing heterogeneous testing procedures and help reducing both maintenance and complexity of operation tasks. (authors)

  9. Nonadiabatic population transfer in a driven four-level system

    International Nuclear Information System (INIS)

    Prants, S.V.

    1994-01-01

    The coherent dynamics of a four-level quantum system with an arbitrary level configuration is described analytically in the modulated polychromatic laser field. The method of dynamical symmetries is invoked to develop the formalism for explicit calculation of the evolution matrix of the system in the resonance fields. The method is free of the usual adiabatic-passage, weak-field approximations, and approximation of the slowly varying amplitudes. The conditions for occurrence of the coherent effects of the total inversion and the total depletion of the initial level of a system driven simultaneously driven simultaneously at several transitions by the laser pulses of arbitrary shape are derived analytically. The obtained results can be applied to problems of the control of quantum processes in multilevel atoms and molecules. 14 refs

  10. High-Level Waste System Process Interface Description

    International Nuclear Information System (INIS)

    D'Entremont, P.D.

    1999-01-01

    The High-Level Waste System is a set of six different processes interconnected by pipelines. These processes function as one large treatment plant that receives, stores, and treats high-level wastes from various generators at SRS and converts them into forms suitable for final disposal. The three major forms are borosilicate glass, which will be eventually disposed of in a Federal Repository, Saltstone to be buried on site, and treated water effluent that is released to the environment

  11. From street level to system level bureaucracies. How ICT is transforming administrative discretion and constitutional control

    NARCIS (Netherlands)

    Bovens, M.A.P.; Zouridis, S.

    2002-01-01

    The use of ICT is rapidly changing the structure of a number of large executive public agencies. They used to be machine bureaucracies in which street level officials exercised ample administrative discretion in dealing with individual clients. This was kept in check by elaborate systems of external

  12. Breakdown of the few-level approximation in collective systems

    International Nuclear Information System (INIS)

    Kiffner, M.; Evers, J.; Keitel, C. H.

    2007-01-01

    The validity of the few-level approximation in dipole-dipole interacting collective systems is discussed. As an example system, we study the archetype case of two dipole-dipole interacting atoms, each modeled by two complete sets of angular momentum multiplets. We establish the breakdown of the few-level approximation by first proving the intuitive result that the dipole-dipole induced energy shifts between collective two-atom states depend on the length of the vector connecting the atoms, but not on its orientation, if complete and degenerate multiplets are considered. A careful analysis of our findings reveals that the simplification of the atomic level scheme by artificially omitting Zeeman sublevels in a few-level approximation generally leads to incorrect predictions. We find that this breakdown can be traced back to the dipole-dipole coupling of transitions with orthogonal dipole moments. Our interpretation enables us to identify special geometries in which partial few-level approximations to two- or three-level systems are valid

  13. Low-level radioactive waste treatment systems in northern Europe

    International Nuclear Information System (INIS)

    Sjoeblom, R.

    1987-08-01

    In the United States, the use of low-level waste (LLW) treatment systems by low level waste generators can be expected to expand with increasing costs for disposal and continuing uncertainty over the availability of disposal space. This development increases the need for performance information and operational data and has prompted the US Department of Energy to commission several compilations of LLW systems experience. The present paper summarizes some of the know-how from Northern Europe where the incentive for LLW treatment and volume reduction is very high since deposition space has not been available for many years. 65 refs., 10 figs., 4 tabs

  14. Continuous liquid level monitoring sensor system using fiber Bragg grating

    Science.gov (United States)

    Sengupta, Dipankar; Kishore, Putha

    2014-01-01

    The design and packaging of simple, small, and low cost sensor heads, used for continuous liquid level measurement using uniformly thinned (etched) optical fiber Bragg grating (FBG) are proposed. The sensor system consists of only an FBG and a simple detection system. The sensitivity of sensor is found to be 23 pm/cm of water column pressure. A linear optical fiber edge filter is designed and developed for the conversion of Bragg wavelength shift to its equivalent intensity. The result shows that relative power measured by a photo detector is linearly proportional to the liquid level. The obtained sensitivity of the sensor is nearly -15 mV/cm.

  15. Serum osteopontin and vitronectin levels in systemic sclerosis.

    Science.gov (United States)

    Gundogdu, Baris; Yolbas, Servet; Yilmaz, Musa; Aydin, Suleyman; Koca, Sulayman Serdar

    2017-11-01

    Osteopontin a matricellular protein has pro-fibrotic effects and binds integrin such as αvβ1 and αvβ3. Vitronectin is one of the integrin αvβ3 ligands and is a multifunctional glycoprotein. The aim of the present study was to evaluate serum osteopontin and vitronectin levels in a cohort of patients with systemic sclerosis (SSc). Eighty-six patients with SSc, 46 patients with systemic lupus erythematosus (SLE), and 38 healthy controls (HC) were enrolled in the study. Serum osteopontin, vitronectin, IL-6, and TGF-β levels were analyzed. Serum osteopontin levels were higher in the SSc and SLE groups compared to the HC group (p < 0.01 and p < 0.001, respectively). However, it was not correlated with disease activity and severity scores in the SSc group. On the other hand, serum vitronectin levels were lower in the SSc group than in the SLE and HC groups (p < 0.001 for both). These results may suggest that osteopontin levels may be increased due to the inflammatory process and osteopontin has not a specific role on fibrosis in SSc. On the other hand, serum vitronectin levels decrease in SSc in contrast to SLE. It may be concluded that the one cause of decreased serum vitronectin levels in SSc may be its accumulation in fibrotic area.

  16. Mixing phases of unstable two-level systems

    International Nuclear Information System (INIS)

    Sokolov, V.V.; Brentano, P. von.

    1993-01-01

    An unstable two-level system decaying into an arbitrary number of channels is considered. It is shown that the mixing phases of the two overlapping resonances can be expressed in the terms of their partial widths and one additional universal mixing parameter. Some applications to a doublet of 2 + resonances in 8 Be and to the ρ-ω systems are considered. 18 refs

  17. Simulating the DIRCM engagement: component and system level performance

    CSIR Research Space (South Africa)

    Willers, CJ

    2012-11-01

    Full Text Available , spectrally matched, pyrophoric. Jammers with arc lamps and steered (directional) beams. Early directional laser beams: soft- kill - jamming & dazzling. Single head, complex gimbals. Advanced direction- al laser beams: hard kill - power levels cause damage... countermeasures (DIRCM), employing high power lamps or lasers as sources of infrared energy. The larger aircraft self-protection scenario, comprising the missile, aircraft and DIRCM hardware is a complex system. In this system, each component presents major...

  18. Classical Information Storage in an n-Level Quantum System

    Science.gov (United States)

    Frenkel, Péter E.; Weiner, Mihály

    2015-12-01

    A game is played by a team of two—say Alice and Bob—in which the value of a random variable x is revealed to Alice only, who cannot freely communicate with Bob. Instead, she is given a quantum n-level system, respectively a classical n-state system, which she can put in possession of Bob in any state she wishes. We evaluate how successfully they managed to store and recover the value of x by requiring Bob to specify a value z and giving a reward of value f ( x, z) to the team. We show that whatever the probability distribution of x and the reward function f are, when using a quantum n-level system, the maximum expected reward obtainable with the best possible team strategy is equal to that obtainable with the use of a classical n-state system. The proof relies on mixed discriminants of positive matrices and—perhaps surprisingly—an application of the Supply-Demand Theorem for bipartite graphs. As a corollary, we get an infinite set of new, dimension dependent inequalities regarding positive operator valued measures and density operators on complex n-space. As a further corollary, we see that the greatest value, with respect to a given distribution of x, of the mutual information I ( x; z) that is obtainable using an n-level quantum system equals the analogous maximum for a classical n-state system.

  19. Design of safeguards information treatment system at the facility level

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dae Yong; Lee, Byung Doo; Kwack, Eun Ho; Choi, Young Myong

    2001-05-01

    We are developing Safeguards Information Treatment System at the facility level(SITS) to manage synthetically safeguards information and to implement efficiently the obligations under the Korea-IAEA Safeguards Agreement, bilateral agreements with other countries and domestic law. In this report, we described the contents of the detailed design of SITS such as database, I/O layout and program. In the present, we are implementing the SITS based on the contents of the design of SITS, and then we plan to provide the system for the facilities after we finish implementing and testing the system.

  20. Design of safeguards information treatment system at the facility level

    International Nuclear Information System (INIS)

    Song, Dae Yong; Lee, Byung Doo; Kwack, Eun Ho; Choi, Young Myong

    2001-05-01

    We are developing Safeguards Information Treatment System at the facility level(SITS) to manage synthetically safeguards information and to implement efficiently the obligations under the Korea-IAEA Safeguards Agreement, bilateral agreements with other countries and domestic law. In this report, we described the contents of the detailed design of SITS such as database, I/O layout and program. In the present, we are implementing the SITS based on the contents of the design of SITS, and then we plan to provide the system for the facilities after we finish implementing and testing the system

  1. An intermediate level of abstraction for computational systems chemistry

    DEFF Research Database (Denmark)

    Andersen, Jakob L.; Flamm, Christoph; Merkle, Daniel

    2017-01-01

    system, well grounded in category theory, at the right level of abstraction for the analysis of large and complex reaction networks. An extension of the basic formalism into the realm of integer hyperflows allows for the identification of complex reaction patterns, such as autocatalysis, in large...

  2. Greenhouse effect, sea level rise, and coastal drainage systems

    Energy Technology Data Exchange (ETDEWEB)

    Titus, J G; Kuo, C Y; Gibbs, M J; LaRoche, T B; Webb, M K; Waddell, J O

    1987-01-01

    Increasing concentrations of carbon dioxide and other gases are expected to warm the earth several degrees in the next century, which would raise sea level a few feet and alter precipitation patterns. Both of these changes would have major impacts on the operation of coastal drainage systems. However, because sea level rise and climate change resulting from the greenhouse effect are still uncertain, most planners and engineers are ignoring the potential implications. Case studies of the potential impact on watersheds in Charleston, South Carolina, and Fort Walton Beach, Florida, suggest that the cost of designing a new system to accommodate a rise in sea level will sometimes be small compared with the retrofit cost that may ultimately be necessary if new systems are not designed for a rise. Rather than ignore the greenhouse effect until its consequences are firmly established, engineers and planners should evaluate whether it would be worthwhile to insure that new systems are not vulnerable to the risks of climate change and sea level rise.

  3. Authentication Assurance Level Application to the Inventory Sampling Measurement System

    International Nuclear Information System (INIS)

    Devaney, Mike M.; Kouzes, Richard T.; Hansen, Randy R.; Geelhood, Bruce D.

    2001-01-01

    This document concentrates on the identification of a standardized assessment approach for the verification of security functionality in specific equipment, the Inspection Sampling Measurement System (ISMS) being developed for MAYAK. Specifically, an Authentication Assurance Level 3 is proposed to be reached in authenticating the ISMS

  4. High-Level System Change: Protecting Business and Society

    Directory of Open Access Journals (Sweden)

    Frank Dixon

    2017-10-01

    Full Text Available Over the past 15 years, sustainability has become mainstream in the corporate and financial sectors. But environmental and social conditions are declining rapidly in many regions. Nearly all corporate and financial sector sustainability strategies are focused on company-level activities, such as unilaterally mitigating negative environmental and social impacts. But flawed economic and political systems make it impossible for businesses to mitigate about 80 percent of negative impacts. These impacts often return to harm companies, for example, in the form of market rejection, lawsuits and reputation damage. System change is the most important sustainability issue. Protecting business and society requires substantially shifting the focus of corporate sustainability strategies from company change to system change. A growing number of collaborative system change efforts are being implemented. Most focus on specific issues, sectors or system flaws. They frequently are ineffective because they do not use a whole system approach. All major aspects of human society are connected. Root causes, key leverage points and most effective solutions often lie outside of issue-specific areas. Climate change, economic reform and other complex issues can only be effectively addressed through a whole system approach. This paper summarizes important economic and political system flaws and describes a collaborative, whole system approach for engaging the corporate and financial sectors in system change.

  5. Prospects for regional safeguards systems - State-level Approach

    International Nuclear Information System (INIS)

    Peixoto, O.J.M.

    2013-01-01

    The increased co-operation with Regional Safeguard's System (RSAC) is a relevant tool for strengthening effectiveness and improving the efficiency of the international safeguard. The new safeguards system that emerges from the application of the Additional Protocol (INFCIRC/540) and the full use of State-level Concept is a challenge and an opportunity for effectively incorporate RSAC into the international safeguards scheme. The challenge is to determine how the co-operation and coordination will be implemented on this new safeguards scheme. This paper presents some discussions and prospects on the issues to be faced by RSAC and IAEA during the implementation of State-level Approach (SLA) using all information available. It is also discussed how different levels of co-operation could be achieved when SLA is applied by IAEA safeguards. The paper is followed by the slides of the presentation. (authors)

  6. Geometric phase for N-level systems through unitary integration

    International Nuclear Information System (INIS)

    Uskov, D. B.; Rau, A. R. P.

    2006-01-01

    Geometric phases are important in quantum physics and are now central to fault-tolerant quantum computation. For spin 1/2, the Bloch sphere S 2 , together with a U(1) phase, provides a complete SU(2) description. We generalize to N-level systems and SU(N) in terms of a 2(N-1)-dimensional base space and reduction to a (N-1)-level problem, paralleling closely the two-dimensional case. This iteratively solves the time evolution of an N-level system and gives (N-1) geometric phases explicitly. A complete analytical construction of an S 4 Bloch-like sphere for two qubits is given for the Spin(5) or SO(5) subgroup of SU(4)

  7. Beam Test of the ATLAS Level-1 Calorimeter Trigger System

    CERN Document Server

    Garvey, J; Mahout, G; Moye, T H; Staley, R J; Thomas, J P; Typaldos, D; Watkins, P M; Watson, A; Achenbach, R; Föhlisch, F; Geweniger, C; Hanke, P; Kluge, E E; Mahboubi, K; Meier, K; Meshkov, P; Rühr, F; Schmitt, K; Schultz-Coulon, H C; Ay, C; Bauss, B; Belkin, A; Rieke, S; Schäfer, U; Tapprogge, T; Trefzger, T; Weber, GA; Eisenhandler, E F; Landon, M; Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J; Gee, C N P; Gillman, A R; Mirea, A; Perera, V J O; Qian, W; Sankey, D P C; Bohm, C; Hellman, S; Hidvegi, A; Silverstein, S

    2005-01-01

    The Level-1 Calorimter Trigger consists of a Preprocessor (PP), a Cluster Processor (CP), and a Jet/Energy-sum Processor (JEP). The CP and JEP receive digitised trigger-tower data from the Preprocessor and produce Region-of-Interest (RoIs) and trigger multiplicities. The latter are sent in real time to the Central Trigger Processor (CTP) where the Level-1 decision is made. On receipt of a Level-1 Accept, Readout Driver Modules (RODs), provide intermediate results to the data acquisition (DAQ) system for monitoring and diagnostic purpose. RoI information is sent to the RoI builder (RoIB) to help reduce the amount of data required for the Level-2 Trigger The Level-1 Calorimeter Trigger System at the test beam consisted of 1 Preprocessor module, 1 Cluster Processor Module, 1 Jet/Energy Module and 2 Common Merger Modules. Calorimeter energies were sucessfully handled thourghout the chain and trigger object sent to the CTP. Level-1 Accepts were sucessfully produced and used to drive the readout path. Online diagno...

  8. Optimal coherent control of dissipative N-level systems

    International Nuclear Information System (INIS)

    Jirari, H.; Poetz, W.

    2005-01-01

    General optimal coherent control of dissipative N-level systems in the Markovian time regime is formulated within Pointryagin's principle and the Lindblad equation. In the present paper, we study feasibility and limitations of steering of dissipative two-, three-, and four-level systems from a given initial pure or mixed state into a desired final state under the influence of an external electric field. The time evolution of the system is computed within the Lindblad equation and a conjugate gradient method is used to identify optimal control fields. The influence of both field-independent population and polarization decay on achieving the objective is investigated in systematic fashion. It is shown that, for realistic dephasing times, optimum control fields can be identified which drive the system into the target state with very high success rate and in economical fashion, even when starting from a poor initial guess. Furthermore, the optimal fields obtained give insight into the system dynamics. However, if decay rates of the system cannot be subjected to electromagnetic control, the dissipative system cannot be maintained in a specific pure or mixed state, in general

  9. Estimating yield gaps at the cropping system level.

    Science.gov (United States)

    Guilpart, Nicolas; Grassini, Patricio; Sadras, Victor O; Timsina, Jagadish; Cassman, Kenneth G

    2017-05-01

    Yield gap analyses of individual crops have been used to estimate opportunities for increasing crop production at local to global scales, thus providing information crucial to food security. However, increases in crop production can also be achieved by improving cropping system yield through modification of spatial and temporal arrangement of individual crops. In this paper we define the cropping system yield potential as the output from the combination of crops that gives the highest energy yield per unit of land and time, and the cropping system yield gap as the difference between actual energy yield of an existing cropping system and the cropping system yield potential. Then, we provide a framework to identify alternative cropping systems which can be evaluated against the current ones. A proof-of-concept is provided with irrigated rice-maize systems at four locations in Bangladesh that represent a range of climatic conditions in that country. The proposed framework identified (i) realistic alternative cropping systems at each location, and (ii) two locations where expected improvements in crop production from changes in cropping intensity (number of crops per year) were 43% to 64% higher than from improving the management of individual crops within the current cropping systems. The proposed framework provides a tool to help assess food production capacity of new systems ( e.g. with increased cropping intensity) arising from climate change, and assess resource requirements (water and N) and associated environmental footprint per unit of land and production of these new systems. By expanding yield gap analysis from individual crops to the cropping system level and applying it to new systems, this framework could also be helpful to bridge the gap between yield gap analysis and cropping/farming system design.

  10. Development of a standardized susceptibility test for Campylobacter with quality control ranges for ciprofloxacin, doxycycline, erythromycin, gentamicin, and meropenem

    DEFF Research Database (Denmark)

    McDermott, P. F.; Bodeis, S. M.; Aarestrup, Frank Møller

    2004-01-01

    -control (QC) strain. Minimal inhibitory concentration (MIC) QC ranges were determined for two incubation time/temperature combinations: 36degreesC for 48 hr and 42degreesC for 24 hr. Quality-control ranges were determined for ciprofloxacin, doxycycline, erythromycin, gentamicin, and meropenem. For all...

  11. Gentamicin-collagen sponge reduces sternal wound complications after heart surgery : A controlled, prospectively randomized, double-blind study

    NARCIS (Netherlands)

    Schimmer, Christoph; Oezkur, Mehmet; Sinha, Bhanu; Hain, Johannes; Gorski, Armin; Hager, Benjamin; Leyh, Rainer

    Objective: Prophylactic retrosternal placement of a gentamicin-collagen sponge has been the subject of several recent clinical studies and is a matter of controversy. The present study is the first controlled, prospective, randomized, double-blind, single-center study to investigate the efficacy of

  12. Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo

    NARCIS (Netherlands)

    Ensing, GT; Roeder, BL; Nelson, JL; van Horn, [No Value; van der Mei, HC; Busscher, HJ; Pitt, WG

    2005-01-01

    Aims: The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. Methods and Results: Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a

  13. Structural Analysis of the Tobramycin and Gentamicin Clinical Resistome Reveals Limitations for Next-generation Aminoglycoside Design.

    Science.gov (United States)

    Bassenden, Angelia V; Rodionov, Dmitry; Shi, Kun; Berghuis, Albert M

    2016-05-20

    Widespread use and misuse of antibiotics has allowed for the selection of resistant bacteria capable of avoiding the effects of antibiotics. The primary mechanism for resistance to aminoglycosides, a broad-spectrum class of antibiotics, is through covalent enzymatic modification of the drug, waning their bactericidal effect. Tobramycin and gentamicin are two medically important aminoglycosides targeted by several different resistance factors, including aminoglycoside 2″-nucleotidyltransferase [ANT(2″)], the primary cause of aminoglycoside resistance in North America. We describe here two crystal structures of ANT(2″), each in complex with AMPCPP, Mn(2+), and either tobramycin or gentamicin. Together these structures outline ANT(2″)'s specificity for clinically used substrates. Importantly, these structures complete our structural knowledge for the set of enzymes that most frequently confer clinically observed resistance to tobramycin and gentamicin. Comparison of tobramycin and gentamicin binding to enzymes in this resistome, as well as to the intended target, the bacterial ribosome, reveals surprising diversity in observed drug-target interactions. Analysis of the diverse binding modes informs that there are limited opportunities for developing aminoglycoside analogs capable of evading resistance.

  14. Delivery of gentamicin from resorbable polymeric carriers as anti-infective strategy for implant-associated osteomyelitis

    NARCIS (Netherlands)

    ter Boo, G.A.

    2016-01-01

    This thesis describes the development of gentamicin loaded resorbable polymeric carriers as anti-infective strategy for implant-associated osteomyelitis and their in vitro and in vivo evaluation. Local delivery of antibiotics has several advantages in the case of trauma to the bone and surrounding

  15. Erosion of the Silicone Peritoneal Dialysis Catheter with the Use of Gentamicin Cream at the Exit Site.

    Science.gov (United States)

    Gardezi, Ali I; Schlageter, Karen W; Foster, Dawn M; Astor, Brad C; Chan, Micah R; Waheed, Sana

    Infection remains the leading complication of peritoneal dialysis (PD). Topical mupirocin and gentamicin are frequently used to prevent infections. Mupirocin ointment has been reported to cause damage to both polyurethane and silicone PD catheters. Gentamicin cream has not been associated with physical damage to catheters.A 64-year-old woman on PD developed relapsing peritonitis with Staphylococcus epidermidis. Because of a drainage problem and white discoloration at the exit site, which is known as " frosting," she underwent catheter exchange. The catheter was found to be fractured within the area of frosting. Four more patients with frosting of the catheter were identified. On further questioning, it was recognized that they were applying excessive amounts of gentamicin cream directly on the catheter surface rather than at the exit site. All patients in the program were educated about the correct method of topical antibiotic application. After the change in practice, no further cases of catheter frosting were identified.Polyurethane catheters can undergo oxidation, mineralization, and environmental stress cracking, leading to physical damage such frosting, ballooning, and fracture. Polyethylene glycol, a component of the mupirocin ointment base, is thought to cause plasticization of polyurethane, reducing its tensile strength. Similar damage has been observed in silicone catheters. Previous reports have not found gentamicin cream to cause that type of damage. We observed that excessive amounts of cream applied directly to the catheter surface can damage it. Damage did not recur once patients had been educated about the proper method of application.

  16. Early postnatal gentamicin and ceftazidime treatment in normal and food restricted neonatal wistar rats: Implications for kidney development.

    Science.gov (United States)

    Bueters, Ruud R G; Jeronimus-Klaasen, Annelies; Brüggemann, Roger J M; van den Heuvel, Lambertus P; Schreuder, Michiel F

    2017-09-01

    Up to two-thirds of premature born neonates are treated for infections with aminoglycosides such as gentamicin. Although acute toxicities are well described, there is uncertainty on developmental changes after treatment of premature born neonates. We studied the effect of gentamicin and ceftazidime on kidney development in the rat. Additionally, we evaluated the modulating effect of extrauterine growth restriction. On postnatal day (PND) 2, Wistar rats were cross-fostered into normal sized litters (12 pups) or large litters (20 pups) to create normal food (NF) or food restricted (FR) litters to simulate growth restriction and dosed daily intraperitoneally with placebo, 4 mg/kg of gentamicin or 50 mg/kg ceftazidime until PND 8. Gentamicin pharmacokinetics were studied in a separate group of animals. Kidneys were weighed. Renal expression of 18 developmental genes was evaluated by quantitative PCR on PND 8. On PND 35, glomerular number was assessed by stereology and glomerular generations were counted. Food restricted litters showed 22% less body weight compared with controls by day 35 (p kidney development, ceftazidime can affect Renin expression, and extrauterine growth restriction impairs kidney development, but did not modulate potential drug toxicity. Birth Defects Research 109:1228-1235, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. Continuous intravenous infusion of ampicillin and gentamicin during parenteral nutrition to 36 newborn infants using a dosage schedule

    DEFF Research Database (Denmark)

    Colding, H; Møller, S; Andersen, G E

    1984-01-01

    Ampicillin and gentamicin were given continuously i.v. to 36 newborn infants using a dosage schedule and the results were compared with those obtained in an earlier study including 88 infants who received individually calculated dosages. With the dosage schedule the variation in the serum concent...

  18. Ferulic acid promotes survival and differentiation of neural stem cells to prevent gentamicin-induced neuronal hearing loss.

    Science.gov (United States)

    Gu, Lintao; Cui, Xinhua; Wei, Wei; Yang, Jia; Li, Xuezhong

    2017-11-15

    Neural stem cells (NSCs) have exhibited promising potential in therapies against neuronal hearing loss. Ferulic acid (FA) has been widely reported to enhance neurogenic differentiation of different stem cells. We investigated the role of FA in promoting NSC transplant therapy to prevent gentamicin-induced neuronal hearing loss. NSCs were isolated from mouse cochlear tissues to establish in vitro culture, which were then treated with FA. The survival and differentiation of NSCs were evaluated. Subsequently, neurite outgrowth and excitability of the in vitro neuronal network were assessed. Gentamicin was used to induce neuronal hearing loss in mice, in the presence and absence of FA, followed by assessments of auditory brainstem response (ABR) and distortion product optoacoustic emissions (DPOAE) amplitude. FA promoted survival, neurosphere formation and differentiation of NSCs, as well as neurite outgrowth and excitability of in vitro neuronal network. Furthermore, FA restored ABR threshold shifts and DPOAE in gentamicin-induced neuronal hearing loss mouse model in vivo. Our data, for the first time, support potential therapeutic efficacy of FA in promoting survival and differentiation of NSCs to prevent gentamicin-induced neuronal hearing loss. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Study of Gentamicin Effect on Staphylococcus Aureus in the Presence of Electromagnetic Field

    Directory of Open Access Journals (Sweden)

    Asghar Tanomand

    2008-06-01

    Full Text Available Introduction:  Nowadays  the  medical,  therapeutic  and  pharmacological  application  of  magnetic  fields  (MF  and  its  biological  effect  has  raised  question  about  the  safety  of  MF.  This  study  aimed  at  scrutinizing the effect of static MF on the resistance of S. aureus to antibiotic.  Materials and Methods: This prospective, case–control study was conducted to evaluate the effect of  low intensity (0.5 mT static MF on the growth rate and the antibiotic resistance of S. aureus sensitive to  gentamicin. The studied bacterium is a nosocomial type and the growth rate was calculated by colony  counting to understand the effect of MF on it. In the next stage, the rate of bacterial growth along with  the different concentration of antibiotic was studied and the Minimum Inhibitory Concentration (MIC  and Minimum Bactericidal Concentration (MBC were determined.  Results: It is concluded that the 0.5 mT MF didn't affect the growth rate of S. aureus after 24 and 48 hours.  The 0.5 mT MF induced a 50 percent decline of MIC and MBC of gentamicin after a 48 hour incubation (MIC  = 4 6g /cc, MBC = 8 6g /cc in the case group vs. MIC = 8 6g /cc, MBC = 16 6g /cc in the control group.  Conclusion: Low–intensity MF didn't affect the bacterial growth rate. However, the bactericidal effects  of gentamicin were greater in the presence of MF. It is possible to apply the static MF for enhancing the  effect of antibiotic on S. aureus.

  20. Multimodal biometric system using rank-level fusion approach.

    Science.gov (United States)

    Monwar, Md Maruf; Gavrilova, Marina L

    2009-08-01

    In many real-world applications, unimodal biometric systems often face significant limitations due to sensitivity to noise, intraclass variability, data quality, nonuniversality, and other factors. Attempting to improve the performance of individual matchers in such situations may not prove to be highly effective. Multibiometric systems seek to alleviate some of these problems by providing multiple pieces of evidence of the same identity. These systems help achieve an increase in performance that may not be possible using a single-biometric indicator. This paper presents an effective fusion scheme that combines information presented by multiple domain experts based on the rank-level fusion integration method. The developed multimodal biometric system possesses a number of unique qualities, starting from utilizing principal component analysis and Fisher's linear discriminant methods for individual matchers (face, ear, and signature) identity authentication and utilizing the novel rank-level fusion method in order to consolidate the results obtained from different biometric matchers. The ranks of individual matchers are combined using the highest rank, Borda count, and logistic regression approaches. The results indicate that fusion of individual modalities can improve the overall performance of the biometric system, even in the presence of low quality data. Insights on multibiometric design using rank-level fusion and its performance on a variety of biometric databases are discussed in the concluding section.

  1. The future for the Global Sea Level Observing System (GLOSS) Sea Level Data Rescue

    Science.gov (United States)

    Bradshaw, Elizabeth; Matthews, Andrew; Rickards, Lesley; Aarup, Thorkild

    2016-04-01

    Historical sea level data are rare and unrepeatable measurements with a number of applications in climate studies (sea level rise), oceanography (ocean currents, tides, surges), geodesy (national datum), geophysics and geology (coastal land movements) and other disciplines. However, long-term time series are concentrated in the northern hemisphere and there are no records at the Permanent Service for Mean Sea Level (PSMSL) global data bank longer than 100 years in the Arctic, Africa, South America or Antarctica. Data archaeology activities will help fill in the gaps in the global dataset and improve global sea level reconstruction. The Global Sea Level Observing System (GLOSS) is an international programme conducted under the auspices of the WMO-IOC Joint Technical Commission for Oceanography and Marine Meteorology. It was set up in 1985 to collect long-term tide gauge observations and to develop systems and standards "for ocean monitoring and flood warning purposes". At the GLOSS-GE-XIV Meeting in 2015, GLOSS agreed on a number of action items to be developed in the next two years. These were: 1. To explore mareogram digitisation applications, including NUNIEAU (more information available at: http://www.mediterranee.cerema.fr/logiciel-de-numerisation-des-enregistrements-r57.html) and other recent developments in scanning/digitisation software, such as IEDRO's Weather Wizards program, to see if they could be used via a browser. 2. To publicise sea level data archaeology and rescue by: • maintaining and regularly updating the Sea Level Data Archaeology page on the GLOSS website • strengthening links to the GLOSS data centres and data rescue organisations e.g. linking to IEDRO, ACRE, RDA • restarting the sea level data rescue blog with monthly posts. 3. Investigate sources of funding for data archaeology and rescue projects. 4. Propose "Guidelines" for rescuing sea level data. These action items will aid the discovery, scanning, digitising and quality control

  2. Incineration systems for low level and mixed wastes

    International Nuclear Information System (INIS)

    Vavruska, J.

    1986-01-01

    A variety of technologies has emerged for incineration of combustible radioactive, hazardous, and mixed wastes. Evaluation and selection of an incineration system for a particular application from such a large field of options are often confusing. This paper presents several current incineration technologies applicable to Low Level Waste (LLW), hazardous waste, and mixed waste combustion treatment. The major technologies reviewed include controlled-air, rotary kiln, fluidized bed, and liquid injection. Coupled with any incineration technique is the need to select a compatible offgas effluent cleaning system. This paper also reviews the various methods of treating offgas emissions for acid vapor, particulates, organics, and radioactivity. Such effluent control systems include the two general types - wet and dry scrubbing with a closer look at quenching, inertial systems, fabric filtration, gas absorption, adsorption, and various other filtration techniques. Selection criteria for overall waste incineration systems are discussed as they relate to waste characterization

  3. Supervision of the ATLAS High Level Trigger System

    CERN Document Server

    Wheeler, S.; Meessen, C.; Qian, Z.; Touchard, F.; Negri, France A.; Zobernig, H.; CHEP 2003 Computing in High Energy Physics; Negri, France A.

    2003-01-01

    The ATLAS High Level Trigger (HLT) system provides software-based event selection after the initial LVL1 hardware trigger. It is composed of two stages, the LVL2 trigger and the Event Filter. The HLT is implemented as software tasks running on large processor farms. An essential part of the HLT is the supervision system, which is responsible for configuring, coordinating, controlling and monitoring the many hundreds of processes running in the HLT. A prototype implementation of the supervision system, using tools from the ATLAS Online Software system is presented. Results from scalability tests are also presented where the supervision system was shown to be capable of controlling over 1000 HLT processes running on 230 nodes.

  4. National high-level waste systems analysis plan

    International Nuclear Information System (INIS)

    Kristofferson, K.; Oholleran, T.P.; Powell, R.H.; Thiel, E.C.

    1995-05-01

    This document details the development of modeling capabilities that can provide a system-wide view of all US Department of Energy (DOE) high-level waste (HLW) treatment and storage systems. This model can assess the impact of budget constraints on storage and treatment system schedules and throughput. These impacts can then be assessed against existing and pending milestones to determine the impact to the overall HLW system. A nation-wide view of waste treatment availability will help project the time required to prepare HLW for disposal. The impacts of the availability of various treatment systems and throughput can be compared to repository readiness to determine the prudent application of resources or the need to renegotiate milestones

  5. An N+3 Technology Level Reference Propulsion System

    Science.gov (United States)

    Jones, Scott M.; Haller, William J.; Tong, Michael To-Hing

    2017-01-01

    An N+3 technology level engine, suitable as a propulsion system for an advanced single-aisle transport, was developed as a reference cycle for use in technology assessment and decision-making efforts. This reference engine serves three main purposes: it provides thermodynamic quantities at each major engine station, it provides overall propulsion system performance data for vehicle designers to use in their analyses, and it can be used for comparison against other proposed N+3 technology-level propulsion systems on an equal basis. This reference cycle is meant to represent the expected capability of gas turbine engines in the N+3 timeframe given reasonable extrapolations of technology improvements and the ability to take full advantage of those improvements.

  6. Expert system for liquid low-level waste management

    International Nuclear Information System (INIS)

    Ferrada, J.J.

    1992-01-01

    An expert system prototype has been developed to support system analysis activities at the Oak Ridge National Laboratory (ORNL) for waste management tasks. This expert system will aid in prioritizing radioactive waste streams for treatment and disposal by evaluating the severity and treatability of the problem as well as the final waste form. The objectives of the expert system development included: (1) collecting information on process treatment technologies for liquid low-level waste (LLLW) that can be incorporated in the knowledge base of the expert system, and (2) producing a prototype that suggests processes and disposal technologies for the ORNL LLLW system. The concept under which the expert system has been designed is integration of knowledge. There are many sources of knowledge (data bases, text files, simulation programs, etc.) that an expert would regularly consult in order to solve a problem of liquid waste management. The expert would normally know how to extract the information from these different sources of knowledge. The general scope of this project would be to include as much pertinent information as possible within the boundaries of the expert system. As a result, the user, who may not be an expert in every aspect of liquid waste management, may be able to apply the content of the information to a specific waste problem. This paper gives the methodological steps to develop the expert system under this general framework

  7. Circulating angiostatin serum level in patients with systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Zofia Gerlicz-Kowalczuk

    2017-12-01

    Full Text Available Introduction : Systemic sclerosis (SSc is achronic connective tissue disease characterized by microangiopathy with inadequate angiogenesis. Angiostatin (AS is a potent antiangiogenic factor specifically inhibiting proliferation and inducing apoptosis of vascular endothelial cells. Aim : To evaluate the level of angiostatin in the serum of patients with SSc. Material and methods : Serum levels of AS were measured in 20 SSc patients and 12 healthy controls. Results : A statistically significant difference in the serum levels of AS in SSc patients was observed compared to the control group (636.51 vs. 869.20 ng/ml; p = 0.012. Significant correlations between limited and disseminated SSc (lSSc/dSSc were not found, however, a difference between lSSc and the control group was demonstrated (620.00 vs. 869.20 ng/ml; p = 0.011. The serum level of AS was not associated positively with organ changes caused by SSc. However, a statistically significant lower serum level of AS was observed in patients with SSc and no esophageal (p = 0.008 or pulmonary changes (p = 0.007 compared to the control group. Conclusions : Our results reveal significant differences in AS level in SSc patients compared to the healthy controls, and suggest that a low level of AS may occur as a result of impaired angiogenesis.

  8. ATW system impact on high-level waste

    International Nuclear Information System (INIS)

    Arthur, E.D.

    1992-01-01

    This report discusses the Accelerator Transmutation of Waste (ATW) concept which aims at destruction of key long-lived radionuclides in high-level nuclear waste (HLW), both fission products and actinides. This focus makes it different from most other transmutation concepts which concentrate primarily on actinide burning. The ATW system uses an accelerator-driven, sub-critical assembly to create an intense thermal neutron environment for radionuclide transmutation. This feature allows rapid transmutation under low-inventory system conditions, which in turn, has a direct impact on the size of chemical separations and materials handling components of the system. Inventories in ATW are factors of eight to thirty times smaller than reactor systems of equivalent thermal power. Chemical separations systems are relatively small in scale and can be optimized to achieve high decontamination factors and minimized waste streams. The low-inventory feature also directly impacts material amounts remaining in the system at its end of life. In addition to its low-inventory operation, the accelerator-driven neutron source features of ATW are key to providing a sufficient level of neutrons to allow transmutation of long-lived fission products

  9. Two-level systems driven by large-amplitude fields

    Science.gov (United States)

    Nori, F.; Ashhab, S.; Johansson, J. R.; Zagoskin, A. M.

    2009-03-01

    We analyze the dynamics of a two-level system subject to driving by large-amplitude external fields, focusing on the resonance properties in the case of driving around the region of avoided level crossing. In particular, we consider three main questions that characterize resonance dynamics: (1) the resonance condition, (2) the frequency of the resulting oscillations on resonance, and (3) the width of the resonance. We identify the regions of validity of different approximations. In a large region of the parameter space, we use a geometric picture in order to obtain both a simple understanding of the dynamics and quantitative results. The geometric approach is obtained by dividing the evolution into discrete time steps, with each time step described by either a phase shift on the basis states or a coherent mixing process corresponding to a Landau-Zener crossing. We compare the results of the geometric picture with those of a rotating wave approximation. We also comment briefly on the prospects of employing strong driving as a useful tool to manipulate two-level systems. S. Ashhab, J.R. Johansson, A.M. Zagoskin, F. Nori, Two-level systems driven by large-amplitude fields, Phys. Rev. A 75, 063414 (2007). S. Ashhab et al, unpublished.

  10. MEDICARE PAYMENTS AND SYSTEM-LEVEL HEALTH-CARE USE

    Science.gov (United States)

    ROBBINS, JACOB A.

    2015-01-01

    The rapid growth of Medicare managed care over the past decade has the potential to increase the efficiency of health-care delivery. Improvements in care management for some may improve efficiency system-wide, with implications for optimal payment policy in public insurance programs. These system-level effects may depend on local health-care market structure and vary based on patient characteristics. We use exogenous variation in the Medicare payment schedule to isolate the effects of market-level managed care enrollment on the quantity and quality of care delivered. We find that in areas with greater enrollment of Medicare beneficiaries in managed care, the non–managed care beneficiaries have fewer days in the hospital but more outpatient visits, consistent with a substitution of less expensive outpatient care for more expensive inpatient care, particularly at high levels of managed care. We find no evidence that care is of lower quality. Optimal payment policies for Medicare managed care enrollees that account for system-level spillovers may thus be higher than those that do not. PMID:27042687

  11. Performance Evaluation at the Hardware Architecture Level and the Operating System Kernel Design Level.

    Science.gov (United States)

    1977-12-01

    program utilizing kernel semaphores for synchronization . The Hydra kernel instructions were sampled at random using the hardware monitor. The changes in...thatf r~i~h olvrAt- 1,o;lil armcrl han itf,. own sell of primitive func ions; and c onparinoms acrosns dif fc’rnt opt ratieg ; .emsf is riot possiblc...kcrnel dcsign level is complicated by the fact that each operating system kernel ha. its own set of primitive functions and compari!ons across

  12. [Multicenter study comparing the efficacy and tolerance of topical ciprofloxacin (0.3%) versus topical gentamicin (0.3%) in the treatment of simple, non-cholesteatomaous chronic otitis media in the suppurative phase].

    Science.gov (United States)

    Lorente, J; Sabater, F; Maristany, M; Jiménez, R; Menem, J; Viñas, J; Quesada, P; Traserra, J; Dicenta, M; Abelló, P

    1995-01-01

    A multicentre double-blind randomized study was carried out to compare topical ciprofloxacin and topical gentamicin in the treatment of simple non-cholesteatomatous purulent chronic otitis media. Three hundred and eight patients were included in the study, 159 treated with ciprofloxacin and 149 treated with gentamicin. The percentage of clinical success (elimination of otorrhoea) was 95% with ciprofloxacin and 94% with gentamicin (ns). Likewise, the percentage of bacteriological erradication was 96% with ciprofloxacin and 93% with gentamicin. Both drugs were well tolerated, without changes in the audiometric values. In these patients, topical ciprofloxacin shows the same efficacy as topical gentamicin without any potential ototoxic effect.

  13. Risk of hearing loss in children exposed to gentamicin for the treatment of sepsis in young infancy: A community based cohort study in pakistan

    International Nuclear Information System (INIS)

    Iftikhar, U.; Ali, S.A.; Tikmani, S.S.; Zaidi, A.K.; Azam, S.I.; Saleem, S.

    2013-01-01

    Objective: To determine the safety of gentamicin when used in a community setting to treat neonatal sepsis. Methods: The study was conducted in peri-urban areas of Karachi from September 2009 to April 2010. The exposed group consisted of children 6 months to 3 years of age who were treated for sepsis during 0-2 months of age in the community, with a regimen that included gentamicin for at least five days. The control group included children from the same area who never received gentamicin. The outcome measure was hearing loss, which was assessed by Brainstem Evoked Response Audiometry. Results: Of the 255 children enrolled, 125 (49%) received gentamicin, while 130 (51%) were not exposed to gentamicin. Children in the gentamicin exposed group were not at increased risk for hearing loss compared to controls (n=30; 30.9% vs. n=33; 31.4%, RR 0.98; 95% CI: 0.60-1.61). Children with history of ear discharge (RR 1.7) and children with family history of deafness (RR 2.0) were more at risk for having hearing loss. Conclusion: No association was found between hearing loss and gentamicin exposure in a community setting for the management of sepsis in the first two months of life. (author)

  14. Land Sea Level Difference Impacts on Socio-Hydrological System.

    Science.gov (United States)

    Sung, K.; Yu, D. J.; Oh, W. S.; Sangwan, N.

    2016-12-01

    Allowing moderate shocks can be a new solution that helps to build adaptive capacity in society is a rising issue. In Social-Ecological field, Carpenter et al. (2015) suggested that exposure to short-term variability leads to long term resilience by enlarging safe operating space (SOS). The SOS refers to the boundary of favorable state that ecosystem can maintain resilience without imposing certain conditions (Carpenter et al. 2015). Our work is motivated by defining SOS in socio-hydrological system(SHS) because it can be an alternative way for flood management beyond optimized or robust flood control. In this context, large flood events that make system to cross the SOS should be fully managed, but frequent small floods need to be allowed if the system is located in SOS. Especially, land sea level change is critical factor to change flood resilience since it is one of the most substantial disturbance that changes the entire boundary of SOS. In order to have broader perspective of vulnerability and resilience of the coastal region, it is crucial to understand the land sea level dynamics changed with human activities and natural variances.The risk of land sea level change has been researched , but most of these researches have focused on explain cause and effect of land sea level change, paying little attention to its dynamics interacts with human activities. Thus, an objective of this research is to study dynamics of human work, land sea level change and resilience to flood with SOS approach. Especially, we focus on the case in Ganges-Brahmaputra, Bangladesh where has high vulnerability to flood, and is faced with relatively rapid land sea level change problem. To acheive the goal, this study will develop a stylized model by extending the human - flood interaction model combined with relative sea level difference equation. The model describes the dynamics of flood protection system which is changed by SHS and land sea level chage. we will focus on the aggradation

  15. Level and width statistics for a decaying chaotic system

    International Nuclear Information System (INIS)

    Mizutori, S.; Zelevinsky, V.G.

    1993-01-01

    The random matrix ensemble of discretized effective non-hermitian hamiltonians is used for studying local correlations and fluctuations of energies and widths in a quantum system where intrinsic levels are coupled to the continuum via a common decay channel. With the use of analytical estimates and numerical simulations, generic properties of statistical observables are obtained for the regimes of weak and strong continuum coupling as well as for the transitional region. Typical signals of the transition (width collectivization, disappearance of level repulsion at small spacings and violation of uniformity along the energy axis) are discussed quantitatively. (orig.)

  16. The n-level spectral correlations for chaotic systems

    International Nuclear Information System (INIS)

    Nagao, Taro; Mueller, Sebastian

    2009-01-01

    We study the n-level spectral correlation functions of classically chaotic quantum systems without time-reversal symmetry. According to Bohigas, Giannoni and Schmit's universality conjecture, it is expected that the correlation functions are in agreement with the prediction of the circular unitary ensemble (CUE) of random matrices. A semiclassical resummation formalism allows us to express the correlation functions as sums over pseudo-orbits. Using an extended version of the diagonal approximation on the pseudo-orbit sums, we derive the n-level correlation functions identical to the n x n determinantal correlation functions of the CUE.

  17. Very-high-level neutral-beam control system

    International Nuclear Information System (INIS)

    Elischer, V.; Jacobson, V.; Theil, E.

    1981-10-01

    As increasing numbers of neutral beams are added to fusion machines, their operation can consume a significant fraction of a facility's total resources. LBL has developed a very high level control system that allows a neutral beam injector to be treated as a black box with just 2 controls: one to set the beam power and one to set the pulse duration. This 2 knob view allows simple operation and provides a natural base for implementing even higher level controls such as automatic source conditioning

  18. The D0 level three data acquisition system

    International Nuclear Information System (INIS)

    Chapin, D.

    2004-01-01

    The DZERO experiment located at Fermilab has recently started RunII with an upgraded detector. The RunII physics program requires the Data Acquisition to readout the detector at a rate of 1 KHz. Events fragments, totaling 250 KB, are readout from approximately 60 front end crates and sent to a particular farm node for Level 3 Trigger processing. A scalable system, capable of complex event routing, has been designed and implemented based on commodity components: VMIC 7750 Single Board Computers for readout, a Cisco 6509 switch for data flow, and close to 100 Linux-based PCs for high-level event filtering

  19. The Level 0 Pixel Trigger system for the ALICE experiment

    International Nuclear Information System (INIS)

    Rinella, G Aglieri; Kluge, A; Krivda, M

    2007-01-01

    The ALICE Silicon Pixel Detector contains 1200 readout chips. Fast-OR signals indicate the presence of at least one hit in the 8192 pixel matrix of each chip. The 1200 bits are transmitted every 100 ns on 120 data readout optical links using the G-Link protocol. The Pixel Trigger System extracts and processes them to deliver an input signal to the Level 0 trigger processor targeting a latency of 800 ns. The system is compact, modular and based on FPGA devices. The architecture allows the user to define and implement various trigger algorithms. The system uses advanced 12-channel parallel optical fiber modules operating at 1310 nm as optical receivers and 12 deserializer chips closely packed in small area receiver boards. Alternative solutions with multi-channel G-Link deserializers implemented directly in programmable hardware devices were investigated. The design of the system and the progress of the ALICE Pixel Trigger project are described in this paper

  20. Subjective visual horizontal during follow-up after unilateral vestibular deafferentation with gentamicin.

    Science.gov (United States)

    Tribukait, A; Bergenius, J; Brantberg, K

    1998-07-01

    The subjective visual horizontal (SVH) was measured by means of a small, rotatable, luminous line in darkness in the upright head and body position and at 10, 20 and 30 degrees of tilt to the right and left before, and repeatedly during a follow-up period of 1 year after intratympanic gentamicin instillations in 12 patients with recurrent vertigo attacks. This treatment caused a loss of the bithermal caloric responses on the diseased side. Shortly after treatment there was a significant tilt of SVH towards the treated side (group mean = 10.6 degrees). Repeated testing made it possible to characterize mathematically the changes with time for SVH. For the group of patients as a whole this otolithic component of vestibular compensation was best described by a power function, SVH = 8.65t(-0.16) degrees, where t is time in days after maximum tilt of SVH. After 1 year, SVH was still significantly tilted towards the treated side (group mean = 3.16 degrees). Gentamicin treatment also caused a significant reduction in the perception of head and body tilt towards the deafferented side, while the perception of tilt towards the healthy side did not show any significant changes. During follow-up there was a gradual improvement in the perception of tilt towards the treated side. However, a significant asymmetry in roll-tilt perception was still present 1 year after deafferentation. There was no correlation between SVH in the upright position and roll-tilt perception, suggesting that these parameters are to some extent dependent on different afferent input from the vestibular organ. They were also found to be complementary for the detection of vestibular disturbance.

  1. Precise mean sea level measurements using the Global Positioning System

    Science.gov (United States)

    Kelecy, Thomas M.; Born, George H.; Parke, Michael E.; Rocken, Christian

    1994-01-01

    This paper describes the results of a sea level measurement test conducted off La Jolla, California, in November of 1991. The purpose of this test was to determine accurate sea level measurements using a Global Positioning System (GPS) equipped buoy. These measurements were intended to be used as the sea level component for calibration of the ERS 1 satellite altimeter. Measurements were collected on November 25 and 28 when the ERS 1 satellite overflew the calibration area. Two different types of buoys were used. A waverider design was used on November 25 and a spar design on November 28. This provided the opportunity to examine how dynamic effects of the measurement platform might affect the sea level accuracy. The two buoys were deployed at locations approximately 1.2 km apart and about 15 km west of a reference GPS receiver located on the rooftop of the Institute of Geophysics and Planetary Physics at the Scripps Institute of Oceanography. GPS solutions were computed for 45 minutes on each day and used to produce two sea level time series. An estimate of the mean sea level at both locations was computed by subtracting tide gage data collected at the Scripps Pier from the GPS-determined sea level measurements and then filtering out the high-frequency components due to waves and buoy dynamics. In both cases the GPS estimate differed from Rapp's mean altimetric surface by 0.06 m. Thus, the gradient in the GPS measurements matched the gradient in Rapp's surface. These results suggest that accurate sea level can be determined using GPS on widely differing platforms as long as care is taken to determine the height of the GPS antenna phase center above water level. Application areas include measurement of absolute sea level, of temporal variations in sea level, and of sea level gradients (dominantly the geoid). Specific applications would include ocean altimeter calibration, monitoring of sea level in remote regions, and regional experiments requiring spatial and

  2. Public health preparedness in Alberta: a systems-level study.

    Science.gov (United States)

    Moore, Douglas; Shiell, Alan; Noseworthy, Tom; Russell, Margaret; Predy, Gerald

    2006-12-28

    Recent international and national events have brought critical attention to the Canadian public health system and how prepared the system is to respond to various types of contemporary public health threats. This article describes the study design and methods being used to conduct a systems-level analysis of public health preparedness in the province of Alberta, Canada. The project is being funded under the Health Research Fund, Alberta Heritage Foundation for Medical Research. We use an embedded, multiple-case study design, integrating qualitative and quantitative methods to measure empirically the degree of inter-organizational coordination existing among public health agencies in Alberta, Canada. We situate our measures of inter-organizational network ties within a systems-level framework to assess the relative influence of inter-organizational ties, individual organizational attributes, and institutional environmental features on public health preparedness. The relative contribution of each component is examined for two potential public health threats: pandemic influenza and West Nile virus. The organizational dimensions of public health preparedness depend on a complex mix of individual organizational characteristics, inter-agency relationships, and institutional environmental factors. Our study is designed to discriminate among these different system components and assess the independent influence of each on the other, as well as the overall level of public health preparedness in Alberta. While all agree that competent organizations and functioning networks are important components of public health preparedness, this study is one of the first to use formal network analysis to study the role of inter-agency networks in the development of prepared public health systems.

  3. Public health preparedness in Alberta: a systems-level study

    Directory of Open Access Journals (Sweden)

    Noseworthy Tom

    2006-12-01

    Full Text Available Abstract Background Recent international and national events have brought critical attention to the Canadian public health system and how prepared the system is to respond to various types of contemporary public health threats. This article describes the study design and methods being used to conduct a systems-level analysis of public health preparedness in the province of Alberta, Canada. The project is being funded under the Health Research Fund, Alberta Heritage Foundation for Medical Research. Methods/Design We use an embedded, multiple-case study design, integrating qualitative and quantitative methods to measure empirically the degree of inter-organizational coordination existing among public health agencies in Alberta, Canada. We situate our measures of inter-organizational network ties within a systems-level framework to assess the relative influence of inter-organizational ties, individual organizational attributes, and institutional environmental features on public health preparedness. The relative contribution of each component is examined for two potential public health threats: pandemic influenza and West Nile virus. Discussion The organizational dimensions of public health preparedness depend on a complex mix of individual organizational characteristics, inter-agency relationships, and institutional environmental factors. Our study is designed to discriminate among these different system components and assess the independent influence of each on the other, as well as the overall level of public health preparedness in Alberta. While all agree that competent organizations and functioning networks are important components of public health preparedness, this study is one of the first to use formal network analysis to study the role of inter-agency networks in the development of prepared public health systems.

  4. Architecture Level Safety Analyses for Safety-Critical Systems

    Directory of Open Access Journals (Sweden)

    K. S. Kushal

    2017-01-01

    Full Text Available The dependency of complex embedded Safety-Critical Systems across Avionics and Aerospace domains on their underlying software and hardware components has gradually increased with progression in time. Such application domain systems are developed based on a complex integrated architecture, which is modular in nature. Engineering practices assured with system safety standards to manage the failure, faulty, and unsafe operational conditions are very much necessary. System safety analyses involve the analysis of complex software architecture of the system, a major aspect in leading to fatal consequences in the behaviour of Safety-Critical Systems, and provide high reliability and dependability factors during their development. In this paper, we propose an architecture fault modeling and the safety analyses approach that will aid in identifying and eliminating the design flaws. The formal foundations of SAE Architecture Analysis & Design Language (AADL augmented with the Error Model Annex (EMV are discussed. The fault propagation, failure behaviour, and the composite behaviour of the design flaws/failures are considered for architecture safety analysis. The illustration of the proposed approach is validated by implementing the Speed Control Unit of Power-Boat Autopilot (PBA system. The Error Model Annex (EMV is guided with the pattern of consideration and inclusion of probable failure scenarios and propagation of fault conditions in the Speed Control Unit of Power-Boat Autopilot (PBA. This helps in validating the system architecture with the detection of the error event in the model and its impact in the operational environment. This also provides an insight of the certification impact that these exceptional conditions pose at various criticality levels and design assurance levels and its implications in verifying and validating the designs.

  5. Protocol of source shielding maintenance in a level measurement systems

    International Nuclear Information System (INIS)

    Gonzales, E.; Figueroa, J.

    1996-01-01

    Maintenance labor of the source shielding and locking system is not performed in many Venezuelan enterprises that employ radioactive level gauge in large container. The lack of maintenance and the ambient long lasting action have produced impairment of many devices and their given parts rise to economical and radiological protection problems. In order to help to solve the mentioned problems, principally to reduce the unjustified dose to workers, the IVIC Health Physics Service worked out a protocol to perform, in a safety way, the maintenance of source shielding and its locking system. This protocol is presented in this paper. (authors)

  6. Perturbation Theory for Open Two-Level Nonlinear Quantum Systems

    International Nuclear Information System (INIS)

    Zhang Zhijie; Jiang Dongguang; Wang Wei

    2011-01-01

    Perturbation theory is an important tool in quantum mechanics. In this paper, we extend the traditional perturbation theory to open nonlinear two-level systems, treating decoherence parameter γ as a perturbation. By this virtue, we give a perturbative solution to the master equation, which describes a nonlinear open quantum system. The results show that for small decoherence rate γ, the ratio of the nonlinear rate C to the tunneling coefficient V (i.e., r = C/V) determines the validity of the perturbation theory. For small ratio r, the perturbation theory is valid, otherwise it yields wrong results. (general)

  7. Computerized low-level waste assay system operation manual

    International Nuclear Information System (INIS)

    Jones, D.F.; Cowder, L.R.; Martin, E.R.

    1976-01-01

    An operation and maintenance manual for the computerized low-level waste box counter is presented, which describes routine assay techniques as well as theory of operation treated in sufficient depth so that an experienced assayist can make nonroutine assays. In addition, complete system schematics are included, along with a complete circuit description to facilitate not only maintenance and troubleshooting, but also reproduction of the instrument if desired. Complete software system descriptions are included so far as calculational algorithms are concerned, although detailed instruction listings would have to be obtained from Group R-1 at LASL in order to make machine-language code changes

  8. Nitrated nucleosome levels and neuropsychiatric events in systemic lupus erythematosus;

    DEFF Research Database (Denmark)

    Ferreira, Isabel; Croca, Sara; Raimondo, Maria Gabriella

    2017-01-01

    BACKGROUND: In patients with systemic lupus erythematosus (SLE) there is no serological test that will reliably distinguish neuropsychiatric (NP) events due to active SLE from those due to other causes. Previously we showed that serum levels of nitrated nucleosomes (NN) were elevated in a small...... number of patients with NPSLE. Here we measured serum NN in samples from a larger population of patients with SLE and NP events to see whether elevated serum NN could be a marker for NPSLE. METHODS: We obtained serum samples from patients in the Systemic Lupus International Collaborative Clinics (SLICC...

  9. System-level modeling of acetone-butanol-ethanol fermentation.

    Science.gov (United States)

    Liao, Chen; Seo, Seung-Oh; Lu, Ting

    2016-05-01

    Acetone-butanol-ethanol (ABE) fermentation is a metabolic process of clostridia that produces bio-based solvents including butanol. It is enabled by an underlying metabolic reaction network and modulated by cellular gene regulation and environmental cues. Mathematical modeling has served as a valuable strategy to facilitate the understanding, characterization and optimization of this process. In this review, we highlight recent advances in system-level, quantitative modeling of ABE fermentation. We begin with an overview of integrative processes underlying the fermentation. Next we survey modeling efforts including early simple models, models with a systematic metabolic description, and those incorporating metabolism through simple gene regulation. Particular focus is given to a recent system-level model that integrates the metabolic reactions, gene regulation and environmental cues. We conclude by discussing the remaining challenges and future directions towards predictive understanding of ABE fermentation. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. B Plant low level waste system integrity assessment report

    International Nuclear Information System (INIS)

    Walter, E.J.

    1995-09-01

    This document provides the report of the integrity assessment activities for the B Plant low level waste system. The assessment activities were in response to requirements of the Washington State Dangerous Waste Regulations, Washington Administrative Code (WAC), 173-303-640. This integrity assessment report supports compliance with Hanford Federal Facility Agreement and Consent Order interim milestone target action M-32-07-T03

  11. Companion Cognitive Systems: A Step toward Human-Level AI

    OpenAIRE

    Forbus, Kenneth D.; Hinrichs, Thomas R.

    2006-01-01

    We are developing Companion Cognitive Systems, a new kind of software that can be effectively treated as a collaborator. Aside from their potential utility, we believe this effort is important because it focuses on three key problems that must be solved to achieve human-level AI: Robust reasoning and learning, interactivity, and longevity. We describe the ideas we are using to develop the first architecture for Companions: analogical processing, grounded in cognitive science for reasoning and...

  12. The CMS High Level Trigger System: Experience and Future Development

    CERN Document Server

    Bauer, Gerry; Bowen, Matthew; Branson, James G; Bukowiec, Sebastian; Cittolin, Sergio; Coarasa, J A; Deldicque, Christian; Dobson, Marc; Dupont, Aymeric; Erhan, Samim; Flossdorf, Alexander; Gigi, Dominique; Glege, Frank; Gomez-Reino, R; Hartl, Christian; Hegeman, Jeroen; Holzner, André; Y L Hwong; Masetti, Lorenzo; Meijers, Frans; Meschi, Emilio; Mommsen, R K; O'Dell, Vivian; Orsini, Luciano; Paus, Christoph; Petrucci, Andrea; Pieri, Marco; Polese, Giovanni; Racz, Attila; Raginel, Olivier; Sakulin, Hannes; Sani, Matteo; Schwick, Christoph; Shpakov, Dennis; Simon, M; Spataru, A C; Sumorok, Konstanty

    2012-01-01

    The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.

  13. A systems-level approach for investigating organophosphorus pesticide toxicity.

    Science.gov (United States)

    Zhu, Jingbo; Wang, Jing; Ding, Yan; Liu, Baoyue; Xiao, Wei

    2018-03-01

    The full understanding of the single and joint toxicity of a variety of organophosphorus (OP) pesticides is still unavailable, because of the extreme complex mechanism of action. This study established a systems-level approach based on systems toxicology to investigate OP pesticide toxicity by incorporating ADME/T properties, protein prediction, and network and pathway analysis. The results showed that most OP pesticides are highly toxic according to the ADME/T parameters, and can interact with significant receptor proteins to cooperatively lead to various diseases by the established OP pesticide -protein and protein-disease networks. Furthermore, the studies that multiple OP pesticides potentially act on the same receptor proteins and/or the functionally diverse proteins explained that multiple OP pesticides could mutually enhance toxicological synergy or additive on a molecular/systematic level. To the end, the integrated pathways revealed the mechanism of toxicity of the interaction of OP pesticides and elucidated the pathogenesis induced by OP pesticides. This study demonstrates a systems-level approach for investigating OP pesticide toxicity that can be further applied to risk assessments of various toxins, which is of significant interest to food security and environmental protection. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Quantum jumps in a three-level system

    International Nuclear Information System (INIS)

    Javanainen, J.

    1986-01-01

    The authors study fluorescence in a scheme which is easy to treat theoretically: a two-level system driven by a laser and a third metastable state such that slow spontaneous transitions take place both from the excited state of a two-level system to the metastable state and from the metastable state to the ground state of the two-level system. With the aid of the quantum regression theorem the authors calculate the whole photon counting statistics at a detector which records scattering of the laser photons. In the limit of high intensity of the laser, the statistics of photon counts is found to be the same as the statistics of a two-state Markov jumps process. Thus, if the sequence of photon counts can be interpreted as a realization of a stochastic process, in a single experimental run the fluorescence should abruptly turn on and off for random intervals of time. The result is the same as given by the quantum-jump argument

  15. Elevated Adiponectin Serum Levels in Women with Systemic Autoimmune Diseases

    Directory of Open Access Journals (Sweden)

    Éric Toussirot

    2010-01-01

    Full Text Available Adipose tissue produces a wide range of proteins that may influence the immune system. In this study, we assessed the serum levels of leptin, adiponectin, and ghrelin, in association with the measurements of body composition, in 15 female patients with various autoimmune diseases (systemic lupus erythematosus, primary Sjögren's syndrome, sarcoidosis, mixed connective tissue disease, vasculitis, CREST syndrome, and polymyositis and in 15 healthy female controls. There were no statistically significant differences between the patients and controls with regard to serum leptin, serum ghrelin, global fat mass, adiposity, and fat mass in the android or gynoid regions, whereas serum adiponectin levels were higher in patients than controls (16.3±1.6 μg/mL versus 9.7±0.6 μg/mL; =.01. As adiponectin is known to exhibit potent anti-inflammatory properties, a high adiponectinemia in patients with systemic autoimmune disease may mitigate the inflammatory response. However, the precise consequences of these elevated serum adiponectin levels on the metabolic syndrome development and atherosclerotic cardiovascular risk in this patient population still needs to be determined.

  16. System-level integration of active silicon photonic biosensors

    Science.gov (United States)

    Laplatine, L.; Al'Mrayat, O.; Luan, E.; Fang, C.; Rezaiezadeh, S.; Ratner, D. M.; Cheung, K.; Dattner, Y.; Chrostowski, L.

    2017-02-01

    Biosensors based on silicon photonic integrated circuits have attracted a growing interest in recent years. The use of sub-micron silicon waveguides to propagate near-infrared light allows for the drastic reduction of the optical system size, while increasing its complexity and sensitivity. Using silicon as the propagating medium also leverages the fabrication capabilities of CMOS foundries, which offer low-cost mass production. Researchers have deeply investigated photonic sensor devices, such as ring resonators, interferometers and photonic crystals, but the practical integration of silicon photonic biochips as part of a complete system has received less attention. Herein, we present a practical system-level architecture which can be employed to integrate the aforementioned photonic biosensors. We describe a system based on 1 mm2 dies that integrate germanium photodetectors and a single light coupling device. The die are embedded into a 16x16 mm2 epoxy package to enable microfluidic and electrical integration. First, we demonstrate a simple process to mimic Fan-Out Wafer-level-Packaging, which enables low-cost mass production. We then characterize the photodetectors in the photovoltaic mode, which exhibit high sensitivity at low optical power. Finally, we present a new grating coupler concept to relax the lateral alignment tolerance down to +/- 50 μm at 1-dB (80%) power penalty, which should permit non-experts to use the biochips in a"plug-and-play" style. The system-level integration demonstrated in this study paves the way towards the mass production of low-cost and highly sensitive biosensors, and can facilitate their wide adoption for biomedical and agro-environmental applications.

  17. System for indicating the level of material in a container

    International Nuclear Information System (INIS)

    Erb, T.L.

    1980-01-01

    In a radiation detecting system for controlling the level of material in a container, the first counter accumulates pulses generated by a geiger tube at a rate related to the level of material and a second counter accumulates clock pulses. A race condition is established between a NAND circuit indicating that the first counter has reached a predetermined total, and a NAND circuit indicating that the second counter has reached a second predetermined total representing a fixed counting interval. The first NAND circuit to respond to its predetermined total actuates a circuit to reset both counters and, if indicative of the material level being below a predetermined minimum, actuates an alarm or operates a control circuit to add material to the container. In the example shown, an additional NAND circuit responds to a different count in the first counter which count in the same time interval corresponds to a higher level, and when material is being added to the container, the race condition is between two NAND circuits. The effect of this is to provide a hysteresis effect preventing the circuit from 'hunting' around one level of material. (author)

  18. Systemic lupus erythematosus activity and beta two microglobulin levels

    Directory of Open Access Journals (Sweden)

    Thelma Larocca Skare

    Full Text Available CONTEXT AND OBJECTIVE: Systemic lupus erythematosus (SLE is an autoimmune disease with a cyclical clinical course. Evaluation of the clinical activity of this disease is important for choosing the correct treatment. The objective of this study was to analyze the value of beta-2 microglobulin (β2M serum levels in determining SLE clinical activity.DESIGN AND SETTING: Cross-sectional analytical study conducted at the rheumatology outpatient clinic of a private university hospital.METHODS: 129 SLE patients were studied regarding disease activity using SLEDAI (SLE Disease Activity Index and cumulative damage using SLICC ACR (SLE International Collaborating Clinics/American College of Rheumatology Damage Index for SLE. At the same time, the β2M serum level, ESR (erythrocyte sedimentation rate, anti-dsDNA (anti-double-stranded DNA and C3 and C4 complement fractions were determined.RESULTS: β2M levels correlated positively with SLEDAI (P = 0.02 and ESR (P = 0.0009 and negatively with C3 (P = 0.007. Patients who were positive for anti-dsDNA had higher β2M serum levels (P = 0.009.CONCLUSION: β2M levels are elevated in SLE patients with active disease.

  19. Plant Systems Biology at the Single-Cell Level.

    Science.gov (United States)

    Libault, Marc; Pingault, Lise; Zogli, Prince; Schiefelbein, John

    2017-11-01

    Our understanding of plant biology is increasingly being built upon studies using 'omics and system biology approaches performed at the level of the entire plant, organ, or tissue. Although these approaches open new avenues to better understand plant biology, they suffer from the cellular complexity of the analyzed sample. Recent methodological advances now allow plant scientists to overcome this limitation and enable biological analyses of single-cells or single-cell-types. Coupled with the development of bioinformatics and functional genomics resources, these studies provide opportunities for high-resolution systems analyses of plant phenomena. In this review, we describe the recent advances, current challenges, and future directions in exploring the biology of single-cells and single-cell-types to enhance our understanding of plant biology as a system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. High-level PC-based laser system modeling

    Science.gov (United States)

    Taylor, Michael S.

    1991-05-01

    Since the inception of the Strategic Defense Initiative (SDI) there have been a multitude of comparison studies done in an attempt to evaluate the effectiveness and relative sizes of complementary, and sometimes competitive, laser weapon systems. It became more and more apparent that what the systems analyst needed was not only a fast, but a cost effective way to perform high-level trade studies. In the present investigation, a general procedure is presented for the development of PC-based algorithmic systems models for laser systems. This procedure points out all of the major issues that should be addressed in the design and development of such a model. Issues addressed include defining the problem to be modeled, defining a strategy for development, and finally, effective use of the model once developed. Being a general procedure, it will allow a systems analyst to develop a model to meet specific needs. To illustrate this method of model development, a description of the Strategic Defense Simulation - Design To (SDS-DT) model developed and used by Science Applications International Corporation (SAIC) is presented. SDS-DT is a menu-driven, fast executing, PC-based program that can be used to either calculate performance, weight, volume, and cost values for a particular design or, alternatively, to run parametrics on particular system parameters to perhaps optimize a design.

  1. Disentangling multi-level systems: averaging, correlations and memory

    International Nuclear Information System (INIS)

    Wouters, Jeroen; Lucarini, Valerio

    2012-01-01

    We consider two weakly coupled systems and adopt a perturbative approach based on the Ruelle response theory to study their interaction. We propose a systematic way of parameterizing the effect of the coupling as a function of only the variables of a system of interest. Our focus is on describing the impacts of the coupling on the long term statistics rather than on the finite-time behavior. By direct calculation, we find that, at first order, the coupling can be surrogated by adding a deterministic perturbation to the autonomous dynamics of the system of interest. At second order, there are additionally two separate and very different contributions. One is a term taking into account the second-order contributions of the fluctuations in the coupling, which can be parameterized as a stochastic forcing with given spectral properties. The other one is a memory term, coupling the system of interest to its previous history, through the correlations of the second system. If these correlations are known, this effect can be implemented as a perturbation with memory on the single system. In order to treat this case, we present an extension to Ruelle's response theory able to deal with integral operators. We discuss our results in the context of other methods previously proposed for disentangling the dynamics of two coupled systems. We emphasize that our results do not rely on assuming a time scale separation, and, if such a separation exists, can be used equally well to study the statistics of the slow variables and that of the fast variables. By recursively applying the technique proposed here, we can treat the general case of multi-level systems

  2. Design and development of Low Level RF (LLRF) control system

    International Nuclear Information System (INIS)

    Mandi, T.K.; Suman, S.; Pandey, H.K.; Bandyopadhyay, A.

    2015-01-01

    All the linear accelerator cavities of Radioactive Ion Beam have separate RF power amplifiers. In these accelerators, high stabilities of the order of ± 0.5% in amplitude and ± 0.5° in phase of RF signal inside the cavities are required for proper and efficient acceleration of RIB. For this purpose, a low level RF (LLRF) control system is being designed which includes amplitude and phase controllers to ensure efficient and stable operation of the RF accelerators. The RF output of the LLRF system is finally amplified and fed to the accelerator cavities. The LLRF system is based on IQ (In-phase and Quadrature) modulation-demodulation technique in which an IQ modulator and a demodulator has been used to control the amplitude and phase of the RF carrier signal. The HigH-speed DAC and ADC have been used for processing the in-phase (I) and quadrature-phase (Q) components of the RF signal. This system is a closed-loop feedback control system. The feedback signal is obtained from the pick-up of accelerator cavity. PID control method is used to regulate the amplitude and phase of the RF signal to the desired/set value. The control system is optimized for minimum response time with satisfactory performance. The transfer function of the PID controller and the RF cavity is compared with the transfer function of a first order system and the values of proportional gain (Kp), integral gain (Ti) and derivative gain (Td) are obtained from Matlab- Simulink Simulation. The PID controller has been implemented into a high speed microcontroller (LPC2478) for fast operation. A GUI has been developed in NI LabView software to monitor the Amplitude and Phase of the RF signal and control manually if required. The detailed design and development of the control system will be discussed in this paper. (author)

  3. Two-level systems driven by large-amplitude fields

    International Nuclear Information System (INIS)

    Ashhab, S.; Johansson, J. R.; Zagoskin, A. M.; Nori, Franco

    2007-01-01

    We analyze the dynamics of a two-level system subject to driving by large-amplitude external fields, focusing on the resonance properties in the case of driving around the region of avoided level crossing. In particular, we consider three main questions that characterize resonance dynamics: (1) the resonance condition (2) the frequency of the resulting oscillations on resonance, and (3) the width of the resonance. We identify the regions of validity of different approximations. In a large region of the parameter space, we use a geometric picture in order to obtain both a simple understanding of the dynamics and quantitative results. The geometric approach is obtained by dividing the evolution into discrete time steps, with each time step described by either a phase shift on the basis states or a coherent mixing process corresponding to a Landau-Zener crossing. We compare the results of the geometric picture with those of a rotating wave approximation. We also comment briefly on the prospects of employing strong driving as a useful tool to manipulate two-level systems

  4. Community-Level Impacts Projection System (CLIPS). Final report

    Energy Technology Data Exchange (ETDEWEB)

    Monts, J.K.; Bareiss, E.R.

    1979-02-01

    The Community-Level Impacts Projection System includes a set of techniques for providing detailed advance information required for rational planning. The computerized system generates reports which enable the user: to describe the energy development activity in terms of its employment demands and spatial location; to estimate how many in-migrating workers will be required; to estimate the demographic characteristics of the in-migrating workers (e.g., how many elementary school children they will bring); to estimate how many additional secondary employment opportunities (e.g., employment in eating and drinking establishments and grocery stores) will be generated; to estimate what the local area's population levels in various age groups would be both with the project and without it; to estimate community population levels for both the impact case and the baseline case; and to estimate the approximate resource requirements and costs for providing additional municipal facilities and services (e.g., water treatment and distribution, wastewater treatment and collection, gas and electric distribution, police and fire protection, etc.)

  5. The effect of gentamicin-induced readthrough on a novel premature termination codon of CD18 leukocyte adhesion deficiency patients.

    Directory of Open Access Journals (Sweden)

    Amos J Simon

    2010-11-01

    Full Text Available Leukocyte adhesion deficiency 1 (LAD1 is an inherited disorder of neutrophil function. Nonsense mutations in the affected CD18 (ITB2 gene have rarely been described. In other genes containing such mutations, treatments with aminoglycoside types of antibiotics (e.g., gentamicin were reported to partially correct the premature protein termination, by induction of readthrough mechanism.Genetic analysis was performed on 2 LAD1 patients. Expression, functional and immunofluorescence assays of CD18 in the patients were used to determine the in-vivo and in-vitro effects of gentamicin-induced readthrough. A theoretical modeling of the corrected CD18 protein was developed to predict the protein function.We found a novel premature termination codon, C562T (R188X, in exon 6 of the CD18 gene that caused a severe LAD1 phenotype in two unrelated Palestinian children. In-vivo studies on these patients' cells after gentamicin treatment showed abnormal adhesion and chemotactic functions, while in-vitro studies showed mislocalization of the corrected protein to the cytoplasm and not to the cell surface. A theoretical modeling of the corrected CD18 protein suggested that the replacement of the wild type arginine by gentamicin induced tryptophan at the position of the nonsense mutation, although enabled the expression of the entire CD18 protein, this was not sufficient to stabilize the CD18/11 heterodimer at the cell surface.A novel nonsense mutation in the CD18 gene causing a complete absence of CD18 protein and severe LAD1 clinical phenotype is reported. Both in vivo and in vitro treatments with gentamicin resulted in the expression of a corrected full-length dysfunctional or mislocalized CD18 protein. However, while the use of gentamicin increased the expression of CD18, it did not improve leukocyte adhesion and chemotaxis. Moreover, the integrity of the CD18/CD11 complex at the cell surface was impaired, due to abnormal CD18 protein and possibly lack of CD11a

  6. System level traffic shaping in disk servers with heterogeneous protocols

    International Nuclear Information System (INIS)

    Cano, Eric; Kruse, Daniele Francesco

    2014-01-01

    Disk access and tape migrations compete for network bandwidth in CASTORs disk servers, over various protocols: RFIO, Xroot, root and GridFTP. As there are a limited number of tape drives, it is important to keep them busy all the time, at their nominal speed. With potentially 100s of user read streams per server, the bandwidth for the tape migrations has to be guaranteed to a controlled level, and not the fair share the system gives by default. Xroot provides a prioritization mechanism, but using it implies moving exclusively to the Xroot protocol, which is not possible in short to mid-term time frame, as users are equally using all protocols. The greatest commonality of all those protocols is not more than the usage of TCP/IP. We investigated the Linux kernel traffic shaper to control TCP/ IP bandwidth. The performance and limitations of the traffic shaper have been understood in test environment, and satisfactory working point has been found for production. Notably, TCP offload engines' negative impact on traffic shaping, and the limitations of the length of the traffic shaping rules were discovered and measured. A suitable working point has been found and the traffic shaping is now successfully deployed in the CASTOR production systems at CERN. This system level approach could be transposed easily to other environments.

  7. Probabilistic safety criteria at the safety function/system level

    International Nuclear Information System (INIS)

    1989-09-01

    A Technical Committee Meeting was held in Vienna, Austria, from 26-30 January 1987. The objectives of the meeting were: to review the national developments of PSC at the level of safety functions/systems including future trends; to analyse basic principles, assumptions, and objectives; to compare numerical values and the rationale for choosing them; to compile the experience with use of such PSC; to analyse the role of uncertainties in particular regarding procedures for showing compliance. The general objective of establishing PSC at the level of safety functions/systems is to provide a pragmatic tool to evaluate plant safety which is placing emphasis on the prevention principle. Such criteria could thus lead to a better understanding of the importance to safety of the various functions which have to be performed to ensure the safety of the plant, and the engineering means of performing these functions. They would reflect the state-of-the-art in modern PSAs and could contribute to a balance in system design. This report, prepared by the participants of the meeting, reviews the current status and future trends in the field and should assist Member States in developing their national approaches. The draft of this document was also submitted to INSAG to be considered in its work to prepare a document on safety principles for nuclear power plants. Five papers presented at the meeting are also included in this publication. A separate abstract was prepared for each of these papers. Refs, figs and tabs

  8. GPS water level measurements for Indonesia's Tsunami Early Warning System

    Directory of Open Access Journals (Sweden)

    T. Schöne

    2011-03-01

    Full Text Available On Boxing Day 2004, a severe tsunami was generated by a strong earthquake in Northern Sumatra causing a large number of casualties. At this time, neither an offshore buoy network was in place to measure tsunami waves, nor a system to disseminate tsunami warnings to local governmental entities. Since then, buoys have been developed by Indonesia and Germany, complemented by NOAA's Deep-ocean Assessment and Reporting of Tsunamis (DART buoys, and have been moored offshore Sumatra and Java. The suite of sensors for offshore tsunami detection in Indonesia has been advanced by adding GPS technology for water level measurements.

    The usage of GPS buoys in tsunami warning systems is a relatively new approach. The concept of the German Indonesian Tsunami Early Warning System (GITEWS (Rudloff et al., 2009 combines GPS technology and ocean bottom pressure (OBP measurements. Especially for near-field installations where the seismic noise may deteriorate the OBP data, GPS-derived sea level heights provide additional information.

    The GPS buoy technology is precise enough to detect medium to large tsunamis of amplitudes larger than 10 cm. The analysis presented here suggests that for about 68% of the time, tsunamis larger than 5 cm may be detectable.

  9. Document Level Assessment of Document Retrieval Systems in a Pairwise System Evaluation

    Science.gov (United States)

    Rajagopal, Prabha; Ravana, Sri Devi

    2017-01-01

    Introduction: The use of averaged topic-level scores can result in the loss of valuable data and can cause misinterpretation of the effectiveness of system performance. This study aims to use the scores of each document to evaluate document retrieval systems in a pairwise system evaluation. Method: The chosen evaluation metrics are document-level…

  10. Gemfibrozil not fenofibrate decreases systemic glucose level via PPARα.

    Science.gov (United States)

    Song, Danjun; Chu, Zanbo; Min, Luo; Zhen, Tan; Li, Pengxu; Han, Liyuan; Bu, Shizhong; yang, Julin; Gonzale, F J; Liu, Aiming

    2016-04-01

    Concurrence of high glucose or diabetes in patients with dyslipidemia is presenting major challenges for clinicians. Although sporadically reported, a rational basis for the use of fibrates for the treatment of dyslipidemia with concurrent metabolic syndrome has not been established. In this study, wild-type (WT) and Ppara-null (KO) mice were fed a serial gemfibrozil- and fenofibrate-containing diet under the same experimental conditions for 14 days. Glucose level in the blood, glycogen storage in the liver tissues, and the potential toxic responses were assayed. Genes involved in glucose metabolism were determined by quantitative polymerase chain reaction analysis. Both the blood glucose level and the glycogen content in the liver were down-regulated by gemfibrozil but not by fenofibrate in WT mice, in a dose-dependent manner. This decrement did not occur in KO mice for either fibrate agent. Secondary regulation on the transcription of pyruvate kinase, and gluconolactonase were observed following gemfibrozil treatment, which was differential between WT mice and KO mice. Gemfibrozil, not fenofibrate, down-regulates systemic glucose level and glycogen storage in the liver dependent on PPARα, suggesting its potential value for treatment of dyslipidemia with concurrent diabetes or high glucose levels.

  11. Measuring progress of the global sea level observing system

    Science.gov (United States)

    Woodworth, Philip L.; Aarup, Thorkild; Merrifield, Mark; Mitchum, Gary T.; Le Provost, Christian

    Sea level is such a fundamental parameter in the sciences of oceanography geophysics, and climate change, that in the mid-1980s, the Intergovernmental Oceanographic Commission (IOC) established the Global Sea Level Observing System (GLOSS). GLOSS was to improve the quantity and quality of data provided to the Permanent Service for Mean Sea Level (PSMSL), and thereby, data for input to studies of long-term sea level change by the Intergovernmental Panel on Climate Change (IPCC). It would also provide the key data needed for international programs, such as the World Ocean Circulation Experiment (WOCE) and later, the Climate Variability and Predictability Programme (CLIVAR).GLOSS is now one of the main observation components of the Joint Technical Commission for Oceanography and Marine Meteorology (JCOMM) of IOC and the World Meteorological Organization (WMO). Progress and deficiencies in GLOSS were presented in July to the 22nd IOC Assembly at UNESCO in Paris and are contained in the GLOSS Assessment Report (GAR) [IOC, 2003a].

  12. Moisture separator for steam generator level measurement system

    International Nuclear Information System (INIS)

    Cantineau, B.J.

    1987-01-01

    A steam generator level measurement system having a reference leg which is kept full of water by a condensation pot, has a liquid/steam separator in the connecting line between the condensation pot and the steam phase in the steam generator to remove excess liquid from the steam externally of the steam generator. This ensures that the connecting line does not become blocked. The separator pot has an expansion chamber which slows down the velocity of the steam/liquid mixture to aid in separation, and a baffle, to avoid liquid flow into the line connected to the condensate pot. Liquid separated is returned to the steam generator below the water level through a drain line. (author)

  13. Defense High Level Waste Disposal Container System Description Document

    International Nuclear Information System (INIS)

    Pettit, N. E.

    2001-01-01

    The Defense High Level Waste Disposal Container System supports the confinement and isolation of waste within the Engineered Barrier System of the Monitored Geologic Repository (MGR). Disposal containers are loaded and sealed in the surface waste handling facilities, transferred to the underground through the accesses using a rail mounted transporter, and emplaced in emplacement drifts. The defense high level waste (HLW) disposal container provides long-term confinement of the commercial HLW and defense HLW (including immobilized plutonium waste forms [IPWF]) placed within disposable canisters, and withstands the loading, transfer, emplacement, and retrieval loads and environments. US Department of Energy (DOE)-owned spent nuclear fuel (SNF) in disposable canisters may also be placed in a defense HLW disposal container along with commercial HLW waste forms, which is known as co-disposal. The Defense High Level Waste Disposal Container System provides containment of waste for a designated period of time, and limits radionuclide release. The disposal container/waste package maintains the waste in a designated configuration, withstands maximum handling and rockfall loads, limits the individual canister temperatures after emplacement, resists corrosion in the expected handling and repository environments, and provides containment of waste in the event of an accident. Defense HLW disposal containers for HLW disposal will hold up to five HLW canisters. Defense HLW disposal containers for co-disposal will hold up to five HLW canisters arranged in a ring and one DOE SNF canister inserted in the center and/or one or more DOE SNF canisters displacing a HLW canister in the ring. Defense HLW disposal containers also will hold two Multi-Canister Overpacks (MCOs) and two HLW canisters in one disposal container. The disposal container will include outer and inner cylinders, outer and inner cylinder lids, and may include a canister guide. An exterior label will provide a means by

  14. DEVELOPMENT OF THE LEVEL INDICES SYSTEM OF UNIVERSITY INTERNATIONALIZATION

    Directory of Open Access Journals (Sweden)

    Artem R. Denisov

    2015-01-01

    Full Text Available The aim of the investigation is to show possible variants of audit in the higher educational institution while processes of internationalisation (procedures of definition of its level; to find out an estimation method of the received results in the given sphere.Methods. The methods involve comparative analysis, synthesis, range and systematization of information concerning the discussed problem.Results and scientific novelty. The necessity of universities participating in internationalization processes is proved. Existing approaches to internationalization evaluation levels are reviewed, as well as best practices for each criterion. Level indicators of considered process are proposed due to summarising the results of the given review, and also as a result of the coordination of criteria NAFSA and authors’ system of indicators: international programs supporting by a university administration, curricular changes, faculty involving into international research, faculty involving into teaching process, students participation, abroad study support, international students and teachers support. The research demonstrates that to improve the adequacy the system of indicators has to be supplemented with some indicators to evaluate the conformity of a university’s internationalization to its mission; the conformity of a university’s internationalization to the government geopolitics; extracurricular activities of students; cultural aspects of internationalization including communication with local ethnical groups; attractiongetting mechanisms for international students.Practical significance. The proposed system of indicators can be used for an estimation of high school development in internationalisation sphere, and under certain correction and improvement for efficiency definition of development of its academic divisions in the given field.

  15. Operating safety requirements for the intermediate level liquid waste system

    International Nuclear Information System (INIS)

    1980-07-01

    The operation of the Intermediate Level Liquid Waste (ILW) System, which is described in the Final Safety Analysis, consists of two types of operations, namely: (1) the operation of a tank farm which involves the storage and transportation through pipelines of various radioactive liquids; and (2) concentration of the radioactive liquids by evaporation including rejection of the decontaminated condensate to the Waste Treatment Plant and retention of the concentrate. The following safety requirements in regard to these operations are presented: safety limits and limiting control settings; limiting conditions for operation; and surveillance requirements. Staffing requirements, reporting requirements, and steps to be taken in the event of an abnormal occurrence are also described

  16. Development of safeguards information treatment system at the facility level

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Doo; Song, Dae Yong; So, Dong Sup; Kwack, Eun Ho [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-04-01

    Safeguards Information Treatment System(SITS) at the facility level is required to implement efficiently the obligations under the Korea-IAEA Safeguards Agreement, bilateral agreements with other countries and domestic law. In this report, the requirements and major functions of SITS were considered, and the error checking methods and the relationships of safeguards information were reviewed. SITS will be developed to cover the different accounting procedures and methods applied at the various facilities under IAEA safeguards. Also, the resolved result of the Y2K problem in the existing nuclear material accounting program was described. 3 tabs. (Author)

  17. Formal specification and animation of a water level monitoring system

    International Nuclear Information System (INIS)

    Jackson, P.S.; Stokes, P.A.

    1993-03-01

    This report describes the Vienna Development Method (VDM), which is a formal method for software specification and development. VDM evolved out of attempts to use mathematics in programming language specifications in order to avoid ambiguities in specifications written in natural language. This report also describes the use of VDM for a real-time application, where it is used to formally specify the requirements of a water level monitoring system. The procedures and techniques used to produce an executable form (animation) of the specification are covered. (Author)

  18. High level trigger system for the ALICE experiment

    International Nuclear Information System (INIS)

    Frankenfeld, U.; Roehrich, D.; Ullaland, K.; Vestabo, A.; Helstrup, H.; Lien, J.; Lindenstruth, V.; Schulz, M.; Steinbeck, T.; Wiebalck, A.; Skaali, B.

    2001-01-01

    The ALICE experiment at the Large Hadron Collider (LHC) at CERN will detect up to 20,000 particles in a single Pb-Pb event resulting in a data rate of ∼75 MByte/event. The event rate is limited by the bandwidth of the data storage system. Higher rates are possible by selecting interesting events and subevents (High Level trigger) or compressing the data efficiently with modeling techniques. Both require a fast parallel pattern recognition. One possible solution to process the detector data at such rates is a farm of clustered SMP nodes, based on off-the-shelf PCs, and connected by a high bandwidth, low latency network

  19. Systems and methods for displaying data in split dimension levels

    Science.gov (United States)

    Stolte, Chris; Hanrahan, Patrick

    2015-07-28

    Systems and methods for displaying data in split dimension levels are disclosed. In some implementations, a method includes: at a computer, obtaining a dimensional hierarchy associated with a dataset, wherein the dimensional hierarchy includes at least one dimension and a sub-dimension of the at least one dimension; and populating information representing data included in the dataset into a visual table having a first axis and a second axis, wherein the first axis corresponds to the at least one dimension and the second axis corresponds to the sub-dimension of the at least one dimension.

  20. Spanish high level radioactive waste management system issues

    International Nuclear Information System (INIS)

    Espejo, J.M.; Beceiro, A.R.

    1992-01-01

    The Empresa Nacional de Residuos Radiactivos, S.A. (ENRESA) has been limited liability company to be responsible for the management of all kind of radioactive wastes in Spain. This paper provides an overview of the strategy and main lines of action stated in the third General Radioactive Waste Plan, currently in force, for the management of spent nuclear fuel and high - level wastes, as well as an outline of the main related projects, either being developed or foreseen. Aspects concerning the organizational structure, the economic and financing system and the international cooperation are also included

  1. Spanish high level radioactive waste management system issues

    International Nuclear Information System (INIS)

    Ulibarri, A.; Veganzones, A.

    1993-01-01

    The Empresa Nacional de Residuous Radiactivos, S.A. (ENRESA) was set up in 1984 as a state-owned limited liability company to be responsible for the management of all kinds of radioactive wastes in Spain. This paper provides an overview of the strategy and main lines of action stated in the third General Radioactive Waste Plan, currently in force, for the management of spent nuclear fuel and high-level wastes, as well as an outline of the main related projects, either being developed or foreseen. Aspects concerning the organizational structure, the economic and financing system and the international co-operational are also included

  2. Intratympanic gentamicin therapy for control of vertigo in unilateral Meniere's disease : a prospective, double-blind, randomized, placebo-controlled trial

    NARCIS (Netherlands)

    Postema, Rolf J.; Kingma, Charlotte M.; Wit, Hero P.; Albers, Frans W. J.; Van Der Laan, Bernard F. A. M.

    2008-01-01

    Conclusions. Intratympanic application of gentamicin is a relatively safe and efficient treatment for the reduction of complaints of vertigo attacks associated with Meniere's disease. The treatment also reduces the severity of the perceived aural fullness. Objective. To investigate the effectiveness

  3. FEATURES, EVENTS, AND PROCESSES: SYSTEM-LEVEL AND CRITICALITY

    International Nuclear Information System (INIS)

    D.L. McGregor

    2000-01-01

    The primary purpose of this Analysis/Model Report (AMR) is to identify and document the screening analyses for the features, events, and processes (FEPs) that do not easily fit into the existing Process Model Report (PMR) structure. These FEPs include the 3 1 FEPs designated as System-Level Primary FEPs and the 22 FEPs designated as Criticality Primary FEPs. A list of these FEPs is provided in Section 1.1. This AMR (AN-WIS-MD-000019) documents the Screening Decision and Regulatory Basis, Screening Argument, and Total System Performance Assessment (TSPA) Disposition for each of the subject Primary FEPs. This AMR provides screening information and decisions for the TSPA-SR report and provides the same information for incorporation into a project-specific FEPs database. This AMR may also assist reviewers during the licensing-review process

  4. System-level techniques for analog performance enhancement

    CERN Document Server

    Song, Bang-Sup

    2016-01-01

    This book shows readers to avoid common mistakes in circuit design, and presents classic circuit concepts and design approaches from the transistor to the system levels. The discussion is geared to be accessible and optimized for practical designers who want to learn to create circuits without simulations. Topic by topic, the author guides designers to learn the classic analog design skills by understanding the basic electronics principles correctly, and further prepares them to feel confident in designing high-performance, state-of-the art CMOS analog systems. This book combines and presents all in-depth necessary information to perform various design tasks so that readers can grasp essential material, without reading through the entire book. This top-down approach helps readers to build practical design expertise quickly, starting from their understanding of electronics fundamentals. .

  5. Electropolishing decontamination system for high-level waste canisters

    International Nuclear Information System (INIS)

    Larson, D.E.; Berger, D.N.; Allen, R.P.; Bryan, G.H.; Place, B.G.

    1988-10-01

    As part of a US Department of Energy (DOE) project agreement with the Federal Ministry for Research and Technology (BMFT) in the Federal Republic of Germany (FRG). The Nuclear Waste Treatment Program at the Pacific Northwest Laboratory (PNL) is preparing 30 radioactive canisters containing borosilicate glass for use in high-level waste repository related tests at the Asse Salt Mine. After filling, the canisters will be welded closed and decontaminated in preparation for shipping to the FRG. Electropolishing was selected as the primary decontamination approach, and an electropolishing system with associated canister inspection equipment has been designed and fabricated for installation in a large hot cell. This remote electropolishing system, which is currently undergoing preliminary testing, is described in this report. 3 refs., 3 figs., 1 tab

  6. Modularized system for disposal of low-level radioactive waste

    International Nuclear Information System (INIS)

    Mallory, C.W.; DiSibio, R.

    1985-01-01

    A modularized system for the disposal of low-level radioactive waste is presented that attempts to overcome the past problems with shallow land burial and gain public acceptance. All waste received at the disposal site is packaged into reinforced concrete modules which are filled with grout, covered and sealed. The hexagonal shape modules are placed in a closely packed array in a disposal unit. The structural stability provided by the modules allow a protective cover constructed of natural materials to be installed, and the disposal units are decommissioned as they are filled. The modules are designed to be recoverable in the event remedial action is necessary. The cost of disposal with a facility of this type is comparable to current prices of shallow land burial facilities. The system is intended to address the needs of generators, regulators, communities, elected officials, licensees and future generations

  7. FEATURES, EVENTS, AND PROCESSES: SYSTEM-LEVEL AND CRITICALITY

    Energy Technology Data Exchange (ETDEWEB)

    D.L. McGregor

    2000-12-20

    The primary purpose of this Analysis/Model Report (AMR) is to identify and document the screening analyses for the features, events, and processes (FEPs) that do not easily fit into the existing Process Model Report (PMR) structure. These FEPs include the 3 1 FEPs designated as System-Level Primary FEPs and the 22 FEPs designated as Criticality Primary FEPs. A list of these FEPs is provided in Section 1.1. This AMR (AN-WIS-MD-000019) documents the Screening Decision and Regulatory Basis, Screening Argument, and Total System Performance Assessment (TSPA) Disposition for each of the subject Primary FEPs. This AMR provides screening information and decisions for the TSPA-SR report and provides the same information for incorporation into a project-specific FEPs database. This AMR may also assist reviewers during the licensing-review process.

  8. Distributed applications monitoring at system and network level

    CERN Document Server

    Aderholz, Michael; Augé, E; Bagliesi, G; Banistoni, G; Barone, L; Boschini, M; Brunengo, A; Bunn, J J; Butler, J; Campanella, M; Capiluppi, P; D'Amato, M; Darneri, M; Di Mattia, A; Dorokhov, A E; Gagliardi, F; Gaines, I; Gasparini, U; Ghiselli, A; Gordon, J; Grandi, C; Gálvez, P; Harris, F; Holtman, K; Karimäki, V; Karita, Y; Klem, J T; Legrand, I; Leltchouk, M; Linglin, D; Lubrano, P; Luminari, L; McArthur, I C; Michelotto, M; Morita, Y; Nazarenko, A; Newman, H; O'Dell, Vivian; O'Neale, S W; Osculati, B; Pepé, M; Perini, L; Pinfold, James L; Pordes, R; Prelz, F; Putzer, A; Resconi, S; Robertson, L; Rolli, S; Sasaki, T; Sato, H; Schaffer, R D; Schalk, T L; Servoli, L; Sgaravatto, M; Shiers, J; Silvestris, L; Siroli, G P; Sliwa, K; Smith, T; Somigliana, R; Stanescu, C; Stockinger, H E; Ugolotti, D; Valente, E; Vistoli, C; Wilkinson, R P; Willers, Ian Malcolm; Williams, D O

    2001-01-01

    Most distributed applications are based on architectural models that do not involve real-time knowledge of network status and of their network usage. Moreover the new "network aware" architectures are still under development and their design is not yet complete. We considered, as a use case, an application using ODBMS (Objectivity /DB) for the distributed analysis of experimental data. The dynamic usage of system and network resources at host and application levels has been measured in different client/server configurations, and on several LAN and WAN layouts. The aim was to study the application efficiency and behavior versus the network characteristics and conditions. The most interesting results of the LAN and WAN tests are described. System bottlenecks and limitations have been identified, and efficient working conditions in the different scenarios have been defined. The behavior observed when moving away from the optimal working conditions is also described.

  9. Mapping how local perturbations influence systems-level brain dynamics.

    Science.gov (United States)

    Gollo, Leonardo L; Roberts, James A; Cocchi, Luca

    2017-10-15

    The human brain exhibits a distinct spatiotemporal organization that supports brain function and can be manipulated via local brain stimulation. Such perturbations to local cortical dynamics are globally integrated by distinct neural systems. However, it remains unclear how local changes in neural activity affect large-scale system dynamics. Here, we briefly review empirical and computational studies addressing how localized perturbations affect brain activity. We then systematically analyze a model of large-scale brain dynamics, assessing how localized changes in brain activity at the different sites affect whole-brain dynamics. We find that local stimulation induces changes in brain activity that can be summarized by relatively smooth tuning curves, which relate a region's effectiveness as a stimulation site to its position within the cortical hierarchy. Our results also support the notion that brain hubs, operating in a slower regime, are more resilient to focal perturbations and critically contribute to maintain stability in global brain dynamics. In contrast, perturbations of peripheral regions, characterized by faster activity, have greater impact on functional connectivity. As a parallel with this region-level result, we also find that peripheral systems such as the visual and sensorimotor networks were more affected by local perturbations than high-level systems such as the cingulo-opercular network. Our findings highlight the importance of a periphery-to-core hierarchy to determine the effect of local stimulation on the brain network. This study also provides novel resources to orient empirical work aiming at manipulating functional connectivity using non-invasive brain stimulation. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. The first-level muon trigger system advances

    CERN Multimedia

    Ellis, N.

    2006-01-01

    Important advances have been made in the last few months in the first-level muon trigger, both for the barrel system and for the endcap system, in a close collaboration between the detector and trigger-electronics groups for the RPCs (Resistive-Plate Chambers) and TGCs (Thin-Gap Chambers). These trigger systems are crucial for the success of the muon-related physics programme of the experiment; events that are not triggered will be lost forever, and the trigger chambers also provide the second coordinate for the reconstruction of muons that are only measured in the bending plane by the MDT detectors. Integration and installation of the barrel muon trigger electronics on the RPC detectors is in full swing. The on-detector electronics consists of more than 800 units each of "Splitter" and "Pad" boxes which have been tested and integrated by a team of physicists, engineers and technicians from Italy and Romania. This work will continue for a further few months until the complete system has been installed and so...

  11. Component-Level Electronic-Assembly Repair (CLEAR) System Architecture

    Science.gov (United States)

    Oeftering, Richard C.; Bradish, Martin A.; Juergens, Jeffrey R.; Lewis, Michael J.; Vrnak, Daniel R.

    2011-01-01

    This document captures the system architecture for a Component-Level Electronic-Assembly Repair (CLEAR) capability needed for electronics maintenance and repair of the Constellation Program (CxP). CLEAR is intended to improve flight system supportability and reduce the mass of spares required to maintain the electronics of human rated spacecraft on long duration missions. By necessity it allows the crew to make repairs that would otherwise be performed by Earth based repair depots. Because of practical knowledge and skill limitations of small spaceflight crews they must be augmented by Earth based support crews and automated repair equipment. This system architecture covers the complete system from ground-user to flight hardware and flight crew and defines an Earth segment and a Space segment. The Earth Segment involves database management, operational planning, and remote equipment programming and validation processes. The Space Segment involves the automated diagnostic, test and repair equipment required for a complete repair process. This document defines three major subsystems including, tele-operations that links the flight hardware to ground support, highly reconfigurable diagnostics and test instruments, and a CLEAR Repair Apparatus that automates the physical repair process.

  12. High-Level Performance Modeling of SAR Systems

    Science.gov (United States)

    Chen, Curtis

    2006-01-01

    SAUSAGE (Still Another Utility for SAR Analysis that s General and Extensible) is a computer program for modeling (see figure) the performance of synthetic- aperture radar (SAR) or interferometric synthetic-aperture radar (InSAR or IFSAR) systems. The user is assumed to be familiar with the basic principles of SAR imaging and interferometry. Given design parameters (e.g., altitude, power, and bandwidth) that characterize a radar system, the software predicts various performance metrics (e.g., signal-to-noise ratio and resolution). SAUSAGE is intended to be a general software tool for quick, high-level evaluation of radar designs; it is not meant to capture all the subtleties, nuances, and particulars of specific systems. SAUSAGE was written to facilitate the exploration of engineering tradeoffs within the multidimensional space of design parameters. Typically, this space is examined through an iterative process of adjusting the values of the design parameters and examining the effects of the adjustments on the overall performance of the system at each iteration. The software is designed to be modular and extensible to enable consideration of a variety of operating modes and antenna beam patterns, including, for example, strip-map and spotlight SAR acquisitions, polarimetry, burst modes, and squinted geometries.

  13. A high rate clarifier for load levelling in sewerage systems.

    Science.gov (United States)

    Jago, R A; Davey, A; Li, H

    2003-01-01

    The combining of chemically assisted clarification with a proprietary physical separation technology has led to a high rate process for clarifying flocculated sewage and other waste streams. This hybrid physico-chemical system, known as the CDS Fine Solids Separation (FSS) System, was developed over a two year period within a sewage treatment plant environment. This paper summarises the results of a recent field trial of the system with a Victorian water authority which experiences heavy loading of sewers in a coastal town during holiday periods. The trial sought to evaluate the FSS as a tool for smoothing the load on the 11 km long sewer to the sewage treatment plant (STP). The FSS system could possibly enable the costly augmentation of the sewer to be deferred, particularly as the capacity of the existing sewer pipe is satisfactory for most of the year. Water quality parameters were determined for a range of flowrates and operational conditions over a two month period. Large reductions were achieved in TSS, TP, FC, turbidity and BOD5, with only minimal reductions in NH3 and TON. These results showed that the FSS could meet the authority's objectives for load levelling and would provide a 20-25% increase in effective sewer capacity. The data are also discussed in terms of possible use of the effluent from the FSS for water reuse applications.

  14. Defense High Level Waste Disposal Container System Description Document

    International Nuclear Information System (INIS)

    2000-01-01

    The Defense High Level Waste Disposal Container System supports the confinement and isolation of waste within the Engineered Barrier System of the Monitored Geologic Repository (MGR). Disposal containers are loaded and sealed in the surface waste handling facilities, transferred to the underground through the accesses using a rail mounted transporter, and emplaced in emplacement drifts. The defense high level waste (HLW) disposal container provides long-term confinement of the commercial HLW and defense HLW (including immobilized plutonium waste forms (IPWF)) placed within disposable canisters, and withstands the loading, transfer, emplacement, and retrieval loads and environments. U.S. Department of Energy (DOE)-owned spent nuclear fuel (SNF) in disposable canisters may also be placed in a defense HLW disposal container along with commercial HLW waste forms, which is known as 'co-disposal'. The Defense High Level Waste Disposal Container System provides containment of waste for a designated period of time, and limits radionuclide release. The disposal container/waste package maintains the waste in a designated configuration, withstands maximum handling and rockfall loads, limits the individual canister temperatures after emplacement, resists corrosion in the expected handling and repository environments, and provides containment of waste in the event of an accident. Defense HLW disposal containers for HLW disposal will hold up to five HLW canisters. Defense HLW disposal containers for co-disposal will hold up to five HLW canisters arranged in a ring and one DOE SNF canister in the ring. Defense HLW disposal containers also will hold two Multi-Canister Overpacks (MCOs) and two HLW canisters in one disposal container. The disposal container will include outer and inner cylinders, outer and inner cylinder lids, and may include a canister guide. An exterior label will provide a means by which to identify the disposal container and its contents. Different materials

  15. Optimal control of multi-level quantum systems

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Robert M.

    2010-12-02

    This thesis is concerned with the control of quantum systems. Given a Hamiltonian model of a quantum system, we are interested in finding controls - typically shaped electromagnetic pulses - that steer the evolution of the system toward a desired target operation. For this we employ a numerical optimisation method known as the GRAPE algorithm. For particular experimental systems, we design control schemes that respect constraints of robustness and addressability, and are within the reach of the experimental hardware. A general procedure is given for specifying a Hamiltonian model of a driven N-level system and converting it to an appropriate rotating frame. This is then applied together with the numerical algorithm to design improved schemes for two different systems, where laser fields manipulate orbital and hyperfine states of Pr{sup 3+} and Rb. The generation of cluster states in Ising-coupled systems is also studied. We find that, in the ideal case, the solution of evolving only under the coupling Hamiltonian is not time-optimal. This surprising result is in contrast to the known cases for unitary gates. For a symmetrised three-qubit example, we provide a geometrical interpretation of this. Numerically optimised control schemes are then developed for a nonideal coupling topology, modelling an experimental configuration of trapped ions. Controls for the implementation of the two-qubit Deutsch and Grover algorithms are designed for a pair of {sup 13}C nuclear spins at a nitrogen vacancy center in diamond. These implementations are robust to experimental errors, and found to be reproduced with high accuracy on a VFG-150 pulse generator. We also consider two-qubit gate synthesis in a system of superconducting qubits coupled by microwave resonators known as the cavity grid. We find that the optimised schemes allow two-qubit operations to be performed between an arbitrary qubit pair on the grid with only a small time overhead, with speedups of 2-4 over the existing

  16. Optimal control of multi-level quantum systems

    International Nuclear Information System (INIS)

    Fisher, Robert M.

    2010-01-01

    This thesis is concerned with the control of quantum systems. Given a Hamiltonian model of a quantum system, we are interested in finding controls - typically shaped electromagnetic pulses - that steer the evolution of the system toward a desired target operation. For this we employ a numerical optimisation method known as the GRAPE algorithm. For particular experimental systems, we design control schemes that respect constraints of robustness and addressability, and are within the reach of the experimental hardware. A general procedure is given for specifying a Hamiltonian model of a driven N-level system and converting it to an appropriate rotating frame. This is then applied together with the numerical algorithm to design improved schemes for two different systems, where laser fields manipulate orbital and hyperfine states of Pr 3+ and Rb. The generation of cluster states in Ising-coupled systems is also studied. We find that, in the ideal case, the solution of evolving only under the coupling Hamiltonian is not time-optimal. This surprising result is in contrast to the known cases for unitary gates. For a symmetrised three-qubit example, we provide a geometrical interpretation of this. Numerically optimised control schemes are then developed for a nonideal coupling topology, modelling an experimental configuration of trapped ions. Controls for the implementation of the two-qubit Deutsch and Grover algorithms are designed for a pair of 13 C nuclear spins at a nitrogen vacancy center in diamond. These implementations are robust to experimental errors, and found to be reproduced with high accuracy on a VFG-150 pulse generator. We also consider two-qubit gate synthesis in a system of superconducting qubits coupled by microwave resonators known as the cavity grid. We find that the optimised schemes allow two-qubit operations to be performed between an arbitrary qubit pair on the grid with only a small time overhead, with speedups of 2-4 over the existing schemes

  17. Integrated software system for low level waste management

    International Nuclear Information System (INIS)

    Worku, G.

    1995-01-01

    In the continually changing and uncertain world of low level waste management, many generators in the US are faced with the prospect of having to store their waste on site for the indefinite future. This consequently increases the set of tasks performed by the generators in the areas of packaging, characterizing, classifying, screening (if a set of acceptance criteria applies), and managing the inventory for the duration of onsite storage. When disposal sites become available, it is expected that the work will require re-evaluating the waste packages, including possible re-processing, re-packaging, or re-classifying in preparation for shipment for disposal under the regulatory requirements of the time. In this day and age, when there is wide use of computers and computer literacy is at high levels, an important waste management tool would be an integrated software system that aids waste management personnel in conducting these tasks quickly and accurately. It has become evident that such an integrated radwaste management software system offers great benefits to radwaste generators both in the US and other countries. This paper discusses one such approach to integrated radwaste management utilizing some globally accepted radiological assessment software applications

  18. Accelerating next generation sequencing data analysis with system level optimizations.

    Science.gov (United States)

    Kathiresan, Nagarajan; Temanni, Ramzi; Almabrazi, Hakeem; Syed, Najeeb; Jithesh, Puthen V; Al-Ali, Rashid

    2017-08-22

    Next generation sequencing (NGS) data analysis is highly compute intensive. In-memory computing, vectorization, bulk data transfer, CPU frequency scaling are some of the hardware features in the modern computing architectures. To get the best execution time and utilize these hardware features, it is necessary to tune the system level parameters before running the application. We studied the GATK-HaplotypeCaller which is part of common NGS workflows, that consume more than 43% of the total execution time. Multiple GATK 3.x versions were benchmarked and the execution time of HaplotypeCaller was optimized by various system level parameters which included: (i) tuning the parallel garbage collection and kernel shared memory to simulate in-memory computing, (ii) architecture-specific tuning in the PairHMM library for vectorization, (iii) including Java 1.8 features through GATK source code compilation and building a runtime environment for parallel sorting and bulk data transfer (iv) the default 'on-demand' mode of CPU frequency is over-clocked by using 'performance-mode' to accelerate the Java multi-threads. As a result, the HaplotypeCaller execution time was reduced by 82.66% in GATK 3.3 and 42.61% in GATK 3.7. Overall, the execution time of NGS pipeline was reduced to 70.60% and 34.14% for GATK 3.3 and GATK 3.7 respectively.

  19. Risk communication system for high level radioactive waste disposal

    International Nuclear Information System (INIS)

    Kugo, Akihide; Uda, Akinobu; Shimoda, Hirosi; Yoshikawa, Hidekazu; Ito, Kyoko; Wakabayashi, Yasunaga

    2005-01-01

    In order to gain a better understanding and acceptance of the task of implementing high level radioactive waste disposal, a study on new communication system about social risk information has been initiated by noticing the rapid expansion of Internet in the society. First, text mining method was introduced to identify the core public interest, examining public comments on the technical report of high level radioactive waste disposal. Then we designed the dialog-mode contents based on the theory of norm activation by Schwartz. Finally, the discussion board was mounted on the web site. By constructing such web communication system which includes knowledge base contents, introspective contents, and interactive discussion board, we conducted the experiment for verifying the principles such as that the basic technical knowledge and trust, and social ethics are indispensable in this process to close the perception gap between nuclear specialists and the general public. The participants of the experiment increased their interest in the topics with which they were not familiar and actively posted their opinions on the BBS. The dialog-mode contents were significantly more effective than the knowledge-based contents in promoting introspection that brought people into a greater awareness of problems such as social dilemma. (author)

  20. Contaminated fistula following J-pouch ileoanal reservoir. Treatment with a collagen sponge containing gentamicin and metronidazole. Case report

    DEFF Research Database (Denmark)

    Nielsen, R; Bülow, Steffen; Moesgaard, F

    1991-01-01

    In a 55-year-old woman, a 1 x 5 cm fistula developed in the ileoanal anastomosis after restorative proctocolectomy with J-pouch ileoanal reservoir and temporary ileostomy for intractable ulcerative colitis. The fistula extended between the pouch and the sacral bone. Lasting closure was achieved b...... by intrafistular placement of a collagen sponge containing gentamicin and soaked in metronidazole solution and pouch drainage through a transanal Foley catheter....

  1. Electrochemical oxidation of drug residues in water by the example of tetracycline, gentamicin and Aspirin {sup trademark}

    Energy Technology Data Exchange (ETDEWEB)

    Weichgrebe, D.; Danilova, E.; Rosenwinkel, K.H. [Inst. of Water Quality and Waste Management, Univ. of Hannover, Hannover (Germany); Vedenjapin, A.; Baturova, M. [Inst. of Organic Chemistry, Russian Academy of Science, Moscow (Russian Federation)

    2003-07-01

    The electrochemical oxidation as a method to destroy drug residues like Aspirin {sup trademark}, tetracycline or gentamicin in water was investigated with C-Anode (modified by manganese oxides) and Pt Anode. The mechanism of Aspirin {sup trademark} and tetracycline oxidation and the influence of the biocide effect was observed using GC-MS and three different microbiological tests. In general the biological availability increases with progressive oxidation of the antibiotics. (orig.)

  2. Hanford high-level waste melter system evaluation data packages

    International Nuclear Information System (INIS)

    Elliott, M.L.; Shafer, P.J.; Lamar, D.A.; Merrill, R.A.; Grunewald, W.; Roth, G.; Tobie, W.

    1996-03-01

    The Tank Waste Remediation System is selecting a reference melter system for the Hanford High-Level Waste vitrification plant. A melter evaluation was conducted in FY 1994 to narrow down the long list of potential melter technologies to a few for testing. A formal evaluation was performed by a Melter Selection Working Group (MSWG), which met in June and August 1994. At the June meeting, MSWG evaluated 15 technologies and selected six for more thorough evaluation at the Aug. meeting. All 6 were variations of joule-heated or induction-heated melters. Between the June and August meetings, Hanford site staff and consultants compiled data packages for each of the six melter technologies as well as variants of the baseline technologies. Information was solicited from melter candidate vendors to supplement existing information. This document contains the data packages compiled to provide background information to MSWG in support of the evaluation of the six technologies. (A separate evaluation was performed by Fluor Daniel, Inc. to identify balance of plant impacts if a given melter system was selected.)

  3. Operation of the Upgraded ATLAS Level-1 Central Trigger System

    CERN Document Server

    Glatzer, Julian Maximilian Volker; The ATLAS collaboration

    2015-01-01

    The ATLAS Level-1 Central Trigger (L1CT) system is a central part of ATLAS data-taking and has undergone a major upgrade for Run 2 of the LHC, in order to cope with the expected increase of instantaneous luminosity of a factor of 2 with respect to Run 1. The upgraded hardware offers more flexibility in the trigger decisions due to the double amount of trigger inputs and usable trigger channels. It also provides an interface to the new topological trigger system. Operationally - particularly useful for commissioning, calibration and test runs - it allows concurrent running of up to 3 different sub-detector combinations. In this contribution, we give an overview of the operational software framework of the L1CT system with particular emphasis of the configuration, controls and monitoring aspects. The software framework allows a consistent configuration with respect to the ATLAS experiment and the LHC machine, upstream and downstream trigger processors, and the data acquisition. Trigger and dead-time rates are m...

  4. Preventive and curative effects of ginger extract against histopathologic changes of gentamicin-induced tubular toxicity in rats

    Directory of Open Access Journals (Sweden)

    Hamid Nasri

    2013-01-01

    Full Text Available Background: Gentamicin (GM is a commonly used aminoglycoside, however, renal toxicity has limited its usage. This study was designed to evaluate the curative and protective effects of Zingiber officinale (ginger against gentamicin tubular toxicity in rats. The phenolic and flavonoid components and antioxidant activity of ginger were also evaluated. Methods: In a preclinical study, 50 male Wistar rats were designated into 5 groups of 10 and treated as follows: Group I: vehicle. Group II: 200 mg/kg/d of ginger for 3 days then, GM (80 mg/kg for 7 days. Group III: 200 mg/kg ginger orally for 3 days, then ginger plus GM for 7 days. Group IV: GM for 7 days. Group V: GM for 10 days. Group VI: GM for 7 days, then 200 mg/kg ginger orally for 10 days. At the end of the study, the animals were sacrificed and their kidneys were histologically evaluated. Results: Ginger could prevent degeneration of the renal cells and reduce the severity of tubular damage caused by gentamicin. However, it could not regenerate the GM degeneration. Conclusions: The results indicate that ginger is effective as a prophylaxis agent, but has not curative effect.

  5. Ethanol extract of Piper longum L. attenuates gentamicin-induced hair cell loss in neonatal cochlea cultures.

    Science.gov (United States)

    Du, Xiao Fei; Song, Jae-Jun; Hong, Seungug; Kim, Jihye

    2012-06-01

    Piper longum L. (PL), also as known as long pepper, a well-known spice and traditional medicine in Asia and Pacific islands, has been reported to exhibit wide spectrum activity including antioxidant activity. However, little information is available on its protective effect on gentamicin (GM) induced ototoxicity which is commonly regarded as being mediated by reactive oxygen species and reactive nitrogen species. This study was undertaken to investigate the protective effect of PL ethanol extract on gentamicin-induced hair cell loss in neonatal cochlea cultures. Cochlea cultures from postnatal day 2-3 mice were used for analysis of the protective effects of PL against gentamicin-induced hair cell loss by phalloidin staining. E. coil cultures were used to determine whether PL interferes with the antibiotic activity of GM. Nitric oxide (NO)-scavenging activity of PL was also measured in vitro. GM induced significant dose-dependent hair cell loss in cochlea cultures. However, without interfering with the antibiotic activity of GM, PL showed a significant and concentration-dependent protective effect against GM-induced hair cell loss, and hair cells retained their stereocilia well. In addition, PL expressed direct scavenging activity toward NO radical liberated within solution of sodium nitroprusside. These findings demonstrate the protective effect of PL on GM-induced hair cell loss in neonatal cochlea cultures, and suggest that it might be of therapeutic benefit for treatment of GM-induced ototoxicity.

  6. Gentamicin Sulfate PEG-PLGA/PLGA-H Nanoparticles: Screening Design and Antimicrobial Effect Evaluation toward Clinic Bacterial Isolates

    Science.gov (United States)

    Dorati, Rossella; DeTrizio, Antonella; Spalla, Melissa; Migliavacca, Roberta; Pagani, Laura; Pisani, Silvia; Chiesa, Enrica; Modena, Tiziana; Genta, Ida

    2018-01-01

    Nanotechnology is a promising approach both for restoring or enhancing activity of old and conventional antimicrobial agents and for treating intracellular infections by providing intracellular targeting and sustained release of drug inside infected cells. The present paper introduces a formulation study of gentamicin loaded biodegradable nanoparticles (Nps). Solid-oil-in water technique was studied for gentamicin sulfate nanoencapsulation using uncapped Polylactide-co-glycolide (PLGA-H) and Polylactide-co-glycolide-co-Polyethylenglycol (PLGA-PEG) blends. Screening design was applied to optimize: drug payload, Nps size and size distribution, stability and resuspendability after freeze-drying. PLGA-PEG concentration resulted most significant factor influencing particles size and drug content (DC): 8 w/w% DC and 200 nm Nps were obtained. Stirring rate resulted most influencing factor for size distribution (PDI): 700 rpm permitted to obtain homogeneous Nps dispersion (PDI = 1). Further experimental parameters investigated, by 23 screening design, were: polymer blend composition (PLGA-PEG and PLGA-H), Polyvinylalcohol (PVA) and methanol concentrations into aqueous phase. Drug content was increased to 10.5 w/w%. Nanoparticle lyophilization was studied adding cryoprotectants, polyvinypirrolidone K17 and K32, and sodiumcarboxymetylcellulose. Freeze-drying protocol was optimized by a mixture design. A freeze-dried Nps powder free resuspendable with stable Nps size and payload, was developed. The powder was tested on clinic bacterial isolates demonstrating that after encapsulation, gentamicin sulfate kept its activity. PMID:29329209

  7. The Artemis workbench for system-level performance evaluation of embedded systems

    NARCIS (Netherlands)

    Pimentel, A.D.

    2008-01-01

    In this paper, we present an overview of the Artemis workbench, which provides modelling and simulation methods and tools for efficient performance evaluation and exploration of heterogeneous embedded multimedia systems. More specifically, we describe the Artemis system-level modelling methodology,

  8. Atomistic study of two-level systems in amorphous silica

    Science.gov (United States)

    Damart, T.; Rodney, D.

    2018-01-01

    Internal friction is analyzed in an atomic-scale model of amorphous silica. The potential energy landscape of more than 100 glasses is explored to identify a sample of about 700 two-level systems (TLSs). We discuss the properties of TLSs, particularly their energy asymmetry and barrier as well as their deformation potential, computed as longitudinal and transverse averages of the full deformation potential tensors. The discrete sampling is used to predict dissipation in the classical regime. Comparison with experimental data shows a better agreement with poorly relaxed thin films than well relaxed vitreous silica, as expected from the large quench rates used to produce numerical glasses. The TLSs are categorized in three types that are shown to affect dissipation in different temperature ranges. The sampling is also used to discuss critically the usual approximations employed in the literature to represent the statistical properties of TLSs.

  9. Low-level wind response to mesoscale pressure systems

    Science.gov (United States)

    Garratt, J. R.; Physick, W. L.

    1983-09-01

    Observations are presented which show a strong correlation between low-level wind behaviour (e.g., rotation near the surface) and the passage of mesoscale pressure systems. The latter are associated with frontal transition zones, are dominated by a pressure-jump line and a mesoscale high pressure area, and produce locally large horizontal pressure gradients. The wind observations are simulated by specifying a time sequence of perturbation pressure gradient and subsequently solving the vertically-integrated momentum equations with appropriate initial conditions. Very good agreement is found between observed and calculated winds; in particular, (i) a 360 ° rotation in wind on passage of the mesoscale high; (ii) wind-shift lines produced dynamically by the pressure-jump line; (iii) rapid linear increase in wind speed on passage of the pressure jump.

  10. Disruptive Logic Architectures and Technologies From Device to System Level

    CERN Document Server

    Gaillardon, Pierre-Emmanuel; Clermidy, Fabien

    2012-01-01

    This book discusses the opportunities offered by disruptive technologies to overcome the economical and physical limits currently faced by the electronics industry. It provides a new methodology for the fast evaluation of an emerging technology from an architectural perspective and discusses the implications from simple circuits to complex architectures. Several technologies are discussed, ranging from 3-D integration of devices (Phase Change Memories, Monolithic 3-D, Vertical NanoWires-based transistors) to dense 2-D arrangements (Double-Gate Carbon Nanotubes, Sublithographic Nanowires, Lithographic Crossbar arrangements). Novel architectural organizations, as well as the associated tools, are presented in order to explore this freshly opened design space. Describes a novel architectural organization for future reconfigurable systems; Includes a complete benchmarking toolflow for emerging technologies; Generalizes the description of reconfigurable circuits in terms of hierarchical levels; Assesses disruptive...

  11. Systems-Level Synthetic Biology for Advanced Biofuel Production

    Energy Technology Data Exchange (ETDEWEB)

    Ruffing, Anne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Travis J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Strickland, Lucas Marshall [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Meserole, Stephen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tallant, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    Cyanobacteria have been shown to be capable of producing a variety of advanced biofuels; however, product yields remain well below those necessary for large scale production. New genetic tools and high throughput metabolic engineering techniques are needed to optimize cyanobacterial metabolisms for enhanced biofuel production. Towards this goal, this project advances the development of a multiple promoter replacement technique for systems-level optimization of gene expression in a model cyanobacterial host: Synechococcus sp. PCC 7002. To realize this multiple-target approach, key capabilities were developed, including a high throughput detection method for advanced biofuels, enhanced transformation efficiency, and genetic tools for Synechococcus sp. PCC 7002. Moreover, several additional obstacles were identified for realization of this multiple promoter replacement technique. The techniques and tools developed in this project will help to enable future efforts in the advancement of cyanobacterial biofuels.

  12. Sida rhomboidea.Roxb leaf extract ameliorates gentamicin induced nephrotoxicity and renal dysfunction in rats.

    Science.gov (United States)

    Thounaojam, Menaka C; Jadeja, Ravirajsinh N; Devkar, Ranjitsinh V; Ramachandran, A V

    2010-10-28

    Sida rhomboidea.Roxb (SR) known as "Mahabala" in Ayurveda and marketed as "Shahadeyi" is used in ethnomedicine to treat ailments such as dysuria and urinary disorders. To evaluate nephroprotective potential of SR against gentamicin (GM) induced nephrotoxicity and renal dysfunction. Nephrotoxicity was induced in rats with GM (100 mg/kg bodyweight (i.p.) for 8 days) and were treated with SR extract (200 and 400 mg/kg bodyweight (p.o.) for 8 days) or 0.5% carboxymethyl cellulose (vehicle). Plasma and urine urea and creatinine, renal enzymatic and non-enzymatic antioxidants along with lipid peroxidation were evaluated in various experimental groups. GM treatment induced significant elevation (p<0.05) in plasma and urine urea, creatinine, renal lipid peroxidation along with significant decrement (p<0.05) in renal enzymatic and non-enzymatic antioxidants. SR treatment to GM treated rats (GM+SR) recorded significant decrement (p<0.05) in plasma and urine urea and creatinine, renal lipid peroxidation along with significant increment (p<0.05) in renal enzymatic and non-enzymatic antioxidants. SR leaf extract ameliorates GM induced nephrotoxicity and renal dysfunction and thus validates its ethnomedicinal use. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Albumin/gentamicin microspheres produced by supercritical assisted atomization: optimization of size, drug loading and release.

    Science.gov (United States)

    Della Porta, G; Adami, R; Del Gaudio, P; Prota, L; Aquino, R; Reverchon, E

    2010-11-01

    In this work, the supercritical assisted atomization (SAA) is proposed, for the first time, not only as a micronization technology but also as a thermal coagulation process for the production of bovine serum albumin (BSA) microspheres charged with Gentamicin sulfate (GS). Particularly, different water solutions of BSA/GS were processed by SAA to produce protein microspheres with different size and antibiotic content. SAA precipitation temperature was selected in the range 100-130 °C to generate protein coagulation and to recover micronized BSA in form of hydrophobic aggregates; GS loading was varied between 10% and 50% (w/w) with an encapsulation efficiency which often reached 100%. In all cases, spherical and noncoalescing particles were successfully produced with a mean particle size of 2 µm and with a standard deviation of about ±1 µm. The microspheres also showed a good stability and constant water content after 60 days of storage. The release profiles of the entrapped drug were monitored using Franz cells to evaluate the possible application of the produced microspheres in wound dressing formulations. Particularly, the microspheres with a BSA/GS ratio of 4:1 after the first burst effect (of 40% of GS loaded) were able to release the GS continuously over 10 days. © 2010 Wiley-Liss, Inc. and the American Pharmacists Association

  14. Synergistic effects of the combination of galangin with gentamicin against methicillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Lee, Young-Seob; Kang, Ok-Hwa; Choi, Jang-Gi; Oh, You-Chang; Chae, Hee-Sung; Kim, Jong Hak; Park, Hyun; Sohn, Dong Hwan; Wang, Zheng-Tao; Kwon, Dong-Yeul

    2008-06-01

    The antimicrobial killing activity toward methicillin-resistant Staphylococcus aureus (MRSA) has been a serious emerging global issue. New effective antimicrobials and/or new approaches to settle this issue are urgently needed. The oriental herb, Alpinia officinarum, has been used in Korea for several hundreds of years to treat various infectious diseases. As it is well known, one of the active constituents of Alpinia officinarum is galangin. Against the 17 strains, the minimum inhibitory concentrations (MICs) of galangin (GAL) were in the range of 62.5 ~ 125 microg/ml, and the MICs of gentamicin (GEN) ranged from 1.9 microg/ml to 2,000 microg/ml. The fractional inhibitory concentrations (FICs) of GAL, in combination with GEN, against 3 test strains were 0.4, 3.9, and 250 microg/ml, and were all 15.62 microg/ml in GEN. The FIC index showed marked synergism in the value range of 0.19 to 0.25. By determining time-kill curves, also confirmed the low synergism of the GAL and GEN combination against 4 h, 8 h, 12 h, and 24 h cultured MRSA. The time-kill study results indicated a low synergistic effect against 3 test strains. Thus, the mixture of GAL and GEN could lead to the development of new combination antibiotics against MRSA infection.

  15. Vehicle-Level Reasoning Systems: Integrating System-Wide Data to Estimate the Instantaneous Health State

    Science.gov (United States)

    Srivastava, Ashok N.; Mylaraswmay, Dinkar; Mah, Robert W.; Cooper, Eric G.

    2011-01-01

    At the aircraft level, a Vehicle-Level Reasoning System (VLRS) can be developed to provide aircraft with at least two significant capabilities: improvement of aircraft safety due to enhanced monitoring and reasoning about the aircrafts health state, and also potential cost savings by enabling Condition Based Maintenance (CBM). Along with the benefits of CBM, an important challenge facing aviation safety today is safeguarding against system and component failures and malfunctions. Faults can arise in one or more aircraft subsystem their effects in one system may propagate to other subsystems, and faults may interact.

  16. Multiwall carbon nanotubes chemically modified carbon paste electrodes for determination of gentamicin sulfate in pharmaceutical preparations and biological fluids.

    Science.gov (United States)

    Khalil, M M; Abed El-Aziz, G M

    2016-02-01

    This article focused on the construction and characteristics of novel and sensitive gentamicin carbon paste electrodes which are based on the incorporation of multiwall carbon nanotubes (MWCNTs) which improve the characteristics of the electrodes. The electrodes were constructed based on gentamicin-phosphotungstate (GNS-PTA) called CPE1, gentamicin-phosphomolybdate (GNS-PMA) called CPE2, GNS-PTA+ MWMCNTs called MWCPE1, and GNS-PMA+ MWMCNTs called MWCPE2. The constructed electrodes, at optimum paste composition, exhibited good Nernstian response for determination of gentamicin sulfate (GNS) over a linear concentration range from 2.5×10(-6) to 1×10(-2), 3.0×10(-6) to 1×10(-2), 4.9×10(-7) to 1×10(-2) and 5.0×10(-7) to 1×10(-2)molL(-1), with lower detection limit 1×10(-6), 1×10(-6), 1.9×10(-7) and 2.2×10(-7)molL(-1), and with slope values of 29.0±0.4, 29.2±0.7, 31.2±0.5 and 31.0±0.6mV/decade for CPE1, CPE2, MWCPE1 and MWCPE2, respectively. The response of electrodes is not affected by pH in the range 3-8 for CPE1 and CPE2 and in the range 2.5-8.5 for MWCPE1 and MWCPE2. The results showed fast dynamic response time (about 8-5s) and long lifetime (more than 2months) for all electrodes. The sensors showed high selectivity for gentamicin sulfate (GNS) with respect to a large number of interfering species. The constructed electrodes were successfully applied for determination of GNS in pure form, its pharmaceutical preparations and biological fluids using standard addition and potentiometric titration methods with high accuracy and precision. Published by Elsevier B.V.

  17. Gentamicin coating of nanotubular anodized titanium implant reduces implant-related osteomyelitis and enhances bone biocompatibility in rabbits

    Directory of Open Access Journals (Sweden)

    Liu D

    2017-07-01

    Full Text Available Denghui Liu,1,* Chongru He,2,* Zhongtang Liu,2 Weidong Xu2 1Department of Orthopedics, the 113 Military Hospital, Ningbo, 2Department of Orthopedics, Changhai Hospital Affiliated to the Second Military Medical University, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: Titanium and titanium alloy are widely used as orthopedic implants for their favorable mechanical properties and satisfactory biocompatibility. The aim of the present study was to investigate the antibacterial effect and bone cell biocompatibility of a novel implant made with nanotubular anodized titanium coated with gentamicin (NTATi-G through in vivo study in ­rabbits. The animals were divided into four groups, each receiving different kinds of implants, that is, NTATi-G, titanium coated with gentamicin (Ti-G, nanotubular anodized titanium uncoated with gentamicin (NTATi and titanium uncoated with gentamicin (Ti. The results showed that NTATi-G implant prevented implant-related osteomyelitis and enhanced bone biocompatibility in vivo. Moreover, the body temperature of rabbits in NTATi-G and Ti-G groups was lower than those in Ti groups, while the weight of rabbits in NTATi-G and Ti-G groups was heavier than those in NTATi and Ti groups, respectively. White blood cell counts in NTATi-G group were lower than NTATi and Ti groups. Features of myelitis were observed by X-ray films in the NTATi and Ti groups, but not in the NTATi-G and Ti-G groups. The radiographic scores, which assessed pathology and histopathology in bone tissues, were significantly lower in the NTATi-G and Ti-G groups than those in the NTATi and Ti groups, respectively (P<0.05. Meanwhile, explants and bone tissue culture demonstrated significantly less bacterial growth in the NTATi-G and Ti-G groups than in the NTATi and Ti groups, respectively (P<0.01. The bone volume in NTATi-G group was greater than Ti-G group, and little bone formation was seen in NTATi and Ti

  18. Graphics Processors in HEP Low-Level Trigger Systems

    International Nuclear Information System (INIS)

    Ammendola, Roberto; Biagioni, Andrea; Chiozzi, Stefano; Ramusino, Angelo Cotta; Cretaro, Paolo; Lorenzo, Stefano Di; Fantechi, Riccardo; Fiorini, Massimiliano; Frezza, Ottorino; Lamanna, Gianluca; Cicero, Francesca Lo; Lonardo, Alessandro; Martinelli, Michele; Neri, Ilaria; Paolucci, Pier Stanislao; Pastorelli, Elena; Piandani, Roberto; Pontisso, Luca; Rossetti, Davide; Simula, Francesco; Sozzi, Marco; Vicini, Piero

    2016-01-01

    Usage of Graphics Processing Units (GPUs) in the so called general-purpose computing is emerging as an effective approach in several fields of science, although so far applications have been employing GPUs typically for offline computations. Taking into account the steady performance increase of GPU architectures in terms of computing power and I/O capacity, the real-time applications of these devices can thrive in high-energy physics data acquisition and trigger systems. We will examine the use of online parallel computing on GPUs for the synchronous low-level trigger, focusing on tests performed on the trigger system of the CERN NA62 experiment. To successfully integrate GPUs in such an online environment, latencies of all components need analysing, networking being the most critical. To keep it under control, we envisioned NaNet, an FPGA-based PCIe Network Interface Card (NIC) enabling GPUDirect connection. Furthermore, it is assessed how specific trigger algorithms can be parallelized and thus benefit from a GPU implementation, in terms of increased execution speed. Such improvements are particularly relevant for the foreseen Large Hadron Collider (LHC) luminosity upgrade where highly selective algorithms will be essential to maintain sustainable trigger rates with very high pileup

  19. Two interacting spins in external fields. Four-level systems

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G.; Baldiotti, M.C.; Gitman, D.M. [Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318-CEP, 05315-970 Sao Paulo, S.P. (Brazil); Levin, A.D. [Dexter Research Center (United States)

    2007-04-15

    In the present article, we consider the so-called two-spin equation that describes four-level quantum systems. Recently, these systems attract attention due to their relation to the problem of quantum computation. We study general properties of the two-spin equation and show that the problem for certain external backgrounds can be identified with the problem of one spin in an appropriate background. This allows one to generate a number of exact solutions for two-spin equations on the basis of already known exact solutions of the one-spin equation. Besides, we present some exact solutions for the two-spin equation with an external background different for each spin but having the same direction. We study the eigenvalue problem for a time-independent spin interaction and a time-independent external background. A possible analogue of the Rabi problem for the two-spin equation is defined. We present its exact solution and demonstrate the existence of magnetic resonances in two specific frequencies, one of them coinciding with the Rabi frequency, and the other depending on the rotating field magnitude. The resonance that corresponds to the second frequency is suppressed with respect to the first one. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  20. PHYSICS OF POLARIZED SCATTERING AT MULTI-LEVEL ATOMIC SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Stenflo, J. O., E-mail: stenflo@astro.phys.ethz.ch [Institute of Astronomy, ETH Zurich, CH-8093 Zurich, SwitzerlandAND (Switzerland); Istituto Ricerche Solari Locarno, Via Patocchi, CH-6605 Locarno-Monti (Switzerland)

    2015-03-01

    The symmetric peak observed in linear polarization in the core of the solar sodium D{sub 1} line at 5896 Å has remained enigmatic since its discovery nearly two decades ago. One reason is that the theory of polarized scattering has not been experimentally tested for multi-level atomic systems in the relevant parameter domains, although the theory is continually being used for the interpretation of astrophysical observations. A laboratory experiment that was set up a decade ago to find out whether the D{sub 1} enigma is a problem of solar physics or quantum physics revealed that the D{sub 1} system has a rich polarization structure in situations where standard scattering theory predicts zero polarization, even when optical pumping of the m state populations of the hyperfine-split ground state is accounted for. Here we show that the laboratory results can be modeled in great quantitative detail if the theory is extended to include the coherences in both the initial and final states of the scattering process. Radiative couplings between the allowed dipole transitions generate coherences in the initial state. Corresponding coherences in the final state are then demanded by a phase closure selection rule. The experimental results for the well understood D{sub 2} line are used to constrain the two free parameters of the experiment, collision rate and optical depth, to suppress the need for free parameters when fitting the D{sub 1} results.

  1. Efficient operating system level virtualization techniques for cloud resources

    Science.gov (United States)

    Ansu, R.; Samiksha; Anju, S.; Singh, K. John

    2017-11-01

    Cloud computing is an advancing technology which provides the servcies of Infrastructure, Platform and Software. Virtualization and Computer utility are the keys of Cloud computing. The numbers of cloud users are increasing day by day. So it is the need of the hour to make resources available on demand to satisfy user requirements. The technique in which resources namely storage, processing power, memory and network or I/O are abstracted is known as Virtualization. For executing the operating systems various virtualization techniques are available. They are: Full System Virtualization and Para Virtualization. In Full Virtualization, the whole architecture of hardware is duplicated virtually. No modifications are required in Guest OS as the OS deals with the VM hypervisor directly. In Para Virtualization, modifications of OS is required to run in parallel with other OS. For the Guest OS to access the hardware, the host OS must provide a Virtual Machine Interface. OS virtualization has many advantages such as migrating applications transparently, consolidation of server, online maintenance of OS and providing security. This paper briefs both the virtualization techniques and discusses the issues in OS level virtualization.

  2. Energy-level statistics and time relaxation in quantum systems

    International Nuclear Information System (INIS)

    Gruver, J.L.; Cerdeira, H.A.; Aliaga, J.; Mello, P.A.; Proto, A.N.

    1997-05-01

    We study a quantum-mechanical system, prepared, at t = 0, in a model state, that subsequently decays into a sea of other states whose energy levels form a discrete spectrum with given statistical properties. An important quantity is the survival probability P(t), defined as the probability, at time t, to find the system in the original model state. Our main purpose is to analyze the influence of the discreteness and statistical properties of the spectrum on the behavior of P(t). Since P(t) itself is a statistical quantity, we restrict our attention to its ensemble average , which is calculated analytically using random-matrix techniques, within certain approximations discussed in the text. We find, for , an exponential decay, followed by a revival, governed by the two-point structure of the statistical spectrum, thus giving a nonzero asymptotic value for large t's. The analytic result compares well with a number of computer simulations, over a time range discussed in the text. (author). 17 refs, 1 fig

  3. Conceptual modular description of the high-level waste management system for system studies model development

    International Nuclear Information System (INIS)

    McKee, R.W.; Young, J.R.; Konzek, G.J.

    1992-08-01

    This document presents modular descriptions of possible alternative components of the federal high-level radioactive waste management system and the procedures for combining these modules to obtain descriptions for alternative configurations of that system. The 20 separate system component modules presented here can be combined to obtain a description of any of the 17 alternative system configurations (i.e., scenarios) that were evaluated in the MRS Systems Studies program (DOE 1989a). First-approximation descriptions of other yet-undefined system configurations could also be developed for system study purposes from this database. The descriptions include, in a modular format, both functional descriptions of the processes in the waste management system, plus physical descriptions of the equipment and facilities necessary for performance of those functions

  4. Sea Level Data Archaeology for the Global Sea Level Observing System (GLOSS)

    Science.gov (United States)

    Bradshaw, Elizabeth; Matthews, Andy; Rickards, Lesley; Jevrejeva, Svetlana

    2015-04-01

    The Global Sea Level Observing System (GLOSS) was set up in 1985 to collect long term tide gauge observations and has carried out a number of data archaeology activities over the past decade, including sending member organisations questionnaires to report on their repositories. The GLOSS Group of Experts (GLOSS GE) is looking to future developments in sea level data archaeology and will provide its user community with guidance on finding, digitising, quality controlling and distributing historic records. Many records may not be held in organisational archives and may instead by in national libraries, archives and other collections. GLOSS will promote a Citizen Science approach to discovering long term records by providing tools for volunteers to report data. Tide gauge data come in two different formats, charts and hand-written ledgers. Charts are paper analogue records generated by the mechanical instrument driving a pen trace. Several GLOSS members have developed software to automatically digitise these charts and the various methods were reported in a paper on automated techniques for the digitization of archived mareograms, delivered to the GLOSS GE 13th meeting. GLOSS is creating a repository of software for scanning analogue charts. NUNIEAU is the only publically available software for digitising tide gauge charts but other organisations have developed their own tide gauge digitising software that is available internally. There are several other freely available software packages that convert image data to numerical values. GLOSS could coordinate a comparison study of the various different digitising software programs by: Sending the same charts to each organisation and asking everyone to digitise them using their own procedures Comparing the digitised data Providing recommendations to the GLOSS community The other major form of analogue sea level data is handwritten ledgers, which are usually observations of high and low waters, but sometimes contain higher

  5. High-Level Waste Systems Plan. Revision 7 (U)

    International Nuclear Information System (INIS)

    Brooke, J.N.; Gregory, M.V.; Paul, P.; Taylor, G.; Wise, F.E.; Davis, N.R.; Wells, M.N.

    1996-10-01

    This revision of the High-Level Waste (HLW) System Plan aligns SRS HLW program planning with the DOE Savannah River (DOE-SR) Ten Year Plan (QC-96-0005, Draft 8/6), which was issued in July 1996. The objective of the Ten Year Plan is to complete cleanup at most nuclear sites within the next ten years. The two key principles of the Ten Year Plan are to accelerate the reduction of the most urgent risks to human health and the environment and to reduce mortgage costs. Accordingly, this System Plan describes the HLW program that will remove HLW from all 24 old-style tanks, and close 20 of those tanks, by 2006 with vitrification of all HLW by 2018. To achieve these goals, the DWPF canister production rate is projected to climb to 300 canisters per year starting in FY06, and remain at that rate through the end of the program in FY18, (Compare that to past System Plans, in which DWPF production peaked at 200 canisters per year, and the program did not complete until 2026.) An additional $247M (FY98 dollars) must be made available as requested over the ten year planning period, including a one-time $10M to enhance Late Wash attainment. If appropriate resources are made available, facility attainment issues are resolved and regulatory support is sufficient, then completion of the HLW program in 2018 would achieve a $3.3 billion cost savings to DOE, versus the cost of completing the program in 2026. Facility status information is current as of October 31, 1996

  6. Models of governance in multihospital systems. Implications for hospital and system-level decision-making.

    Science.gov (United States)

    Morlock, L L; Alexander, J A

    1986-12-01

    This study utilizes data from a national survey of 159 multihospital systems in order to describe the types of governance structures currently being utilized, and to compare the policy making process for various types of decisions in systems with different approaches to governance. Survey results indicate that multihospital systems most often use one of three governance models. Forty-one percent of the systems (including 33% of system hospitals) use a parent holding company model in which there is a system-wide corporate governing board and separate governing boards for each member hospital. Twenty-two percent of systems in the sample (but 47% of all system hospitals) utilize what we have termed a modified parent holding company model in which there is one system-wide governing board, but advisory boards are substituted for governing boards at the local hospital level. Twenty-three percent of the sampled systems (including 11% of system hospitals) use a corporate model in which there is one system-wide governing board but no other governing or advisory boards at either the divisional, regional or local hospital levels. A comparison of systems using these three governance approaches found significant variation in terms of system size, ownership and the geographic proximity of member hospitals. In order to examine the relationship between alternative approaches to governance and patterns of decision-making, the three model types were compared with respect to the percentages of systems reporting that local boards, corporate management and/or system-wide corporate boards have responsibility for decision-making in a number of specific issue areas. Study results indicate that, regardless of model type, corporate boards are most likely to have responsibility for decisions regarding the transfer, pledging and sale of assets; the formation of new companies; purchase of assets greater than $100,000; changes in hospital bylaws; and the appointment of local board members. In

  7. Evaluation of protective effect of hydroalcoholic extract of Crocus sativus petals on preventing of gentamicin induced peliosis hepatis and hepatic telangiectasis in rats: short communication

    Directory of Open Access Journals (Sweden)

    Arash Omidi

    2013-02-01

    Full Text Available Peliosis hepatis is a rare liver disease characterized by blood-filled cavities scattered irregularly throughout the liver. Risk factors for peliosis include chronic illness such as AIDS, tuberculosis, cancer also use of some drugs such as anabolic steroids and azathioprine. The aim of the present study was to evaluate the curative properties of crocus sativus petals on induced peliosis hepatis in rats. Thirty two male Wistar rats (weight: 180-220 g were randomly divided into four equal groups: group 1 (healthy group received only IP normal saline, group2 received IP 80mg/kg.bw gentamicin, group3 IP 80mg/kg.bw gentamicin+ 40mg/kg crocus sativus petal extract, and group 4 was given IP 80mg/kg.bw gentamicin+ 40mg/kg crocus sativus petal extract. At the end of the experiment, the rats were anesthetized and their blood samples were collected through cardiac puncture for AST and ALT measurement.Then, the livers of the subjects were excised and fixed in formalin. It was found that AST significantly increased in gentamicin group (P<0.05 compared to the healthy group and groups treated by means of crocus sativus petal extract .Moreover, there was no significant differences between the groups administered the extract and those given gentamicin. Histologically,heterogeneous multiple blood-filled cavities were observed in gentamicin group (2 and the treatment groups (3 and 4. The results of the present study show that doses of hydroalcoholic extract of crocus sativus do not effect on peliosis hepatic and telangiectasis due to gentamicin sulfate in rats

  8. Studies of labelling conditions for gentamicin with sup(99m)Tc. Complexation with ruthexium. Establishment of pharmacokinetics parameters through compartmental analysis

    International Nuclear Information System (INIS)

    Carvalho, O.G. de.

    1988-01-01

    Gentamicin sulphate is an aminoglycoside antibiotic type specifically used for treatment of infections produced by Gram-negative bacterias but at the other hand it presents ototoxic reactions as a serious side effect. The main purpose of labelling gentamicin with sup(99m)Tc was to obtain a radioactive tracer to carry out biological studies and compartmental analysis of this antibiotic. The optimal labelling conditions of gentamicin sulphate with sup(99m)Tc, using sodium pertechnetate solution eluted from a sup(99)Mo- sup(99m)Tc generator, were stablished by testing different masses of antibiotic, and reduction agent (SnCl sub(2).2H sub(2)O), and also different reaction time and final labelling PH. The same labelling procedure was used with Re (amonium perrenate) in order to obtain some semi-quantitative approximations of the chemical structure of the complex formed, since Re and Tc present similar chemical characteristics. In this way it is possible to suggest the role that the groups NH2 and C-O bonding of the gentamicin play in the complexation process. From the studies of the biological uptake of sup(99m)Tc-gentamicin sulphate in rats, the kidneys showed the highest affinity for the antibiotic. The maximum uptake was observed in 180 to 240 minutes followed by a decrease of it afterwards. For the dose and time used, no significative uptake by the auricular region was detected. Curve of plasma decay of sup(99m)Tc-gentamicin was obtained, and from the exponentials of each beanch of this curve respective half-lives were calculated. Furthermore the apparent volume of distribution was determined, and with the residual radioactivity in the body, the biological half-life and total clearance were obtained. The distribution of sup(99m)Tc-gentamicin in rats was set in a bi-compartments in addition to a retention one for the 24 hours time interval studied. (author)

  9. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  10. DOE systems approach to a low-level waste management information system: summary paper

    International Nuclear Information System (INIS)

    Esparza, V.

    1987-01-01

    The LLWMP is performing an assessment of waste information systems currently in use at each DOE site for recording LLW data. The assessment is being conducted to determine what changes to the waste information systems, if any, are desirable to support implementation of this systems approach to LLW management. Recommendations will be made to DOE from this assessment and what would be involved to modify current DOE waste generator information practices to support an appropriately structured overall DOE LLW data systems. In support of reducing the uncertainty of decision-making, DOE has selected a systems approach to keep pace with an evolving regulatory climate to low-level waste. This approach considers the effects of each stage of the entire low-level waste management process. The proposed systems approach starts with the disposal side of the waste management system and progresses towards the waste generation side of the waste management system. Using this approach provides quantitative performance to be achieved. In addition, a systems approach also provides a method for selecting appropriate technology based on engineering models

  11. Quantification of the level descriptors for the standard EQ-5D three-level system and a five-level version according to two methods

    NARCIS (Netherlands)

    Janssen, M. F.; Birnie, E.; Bonsel, G. J.

    2008-01-01

    OBJECTIVES: Our aim was to compare the quantitative position of the level descriptors of the standard EQ-5D three-level system (3L) and a newly developed, experimental five-level version (5L) using a direct and a vignette-based indirect method. METHODS: Eighty-two respondents took part in the study.

  12. Quantification of the level descriptors for the standard EQ-5D three-level system and a five-level version according to two methods

    NARCIS (Netherlands)

    M.F. Janssen (Bas); E. Birnie (Erwin); G.J. Bonsel (Gouke)

    2008-01-01

    textabstractObjectives: Our aim was to compare the quantitative position of the level descriptors of the standard EQ-5D three-level system (3L) and a newly developed, experimental five-level version (5L) using a direct and a vignette-based indirect method. Methods: Eighty-two respondents took part

  13. Two-level tunneling systems in amorphous alumina

    Science.gov (United States)

    Lebedeva, Irina V.; Paz, Alejandro P.; Tokatly, Ilya V.; Rubio, Angel

    2014-03-01

    The decades of research on thermal properties of amorphous solids at temperatures below 1 K suggest that their anomalous behaviour can be related to quantum mechanical tunneling of atoms between two nearly equivalent states that can be described as a two-level system (TLS). This theory is also supported by recent studies on microwave spectroscopy of superconducting qubits. However, the microscopic nature of the TLS remains unknown. To identify structural motifs for TLSs in amorphous alumina we have performed extensive classical molecular dynamics simulations. Several bistable motifs with only one or two atoms jumping by considerable distance ~ 0.5 Å were found at T=25 K. Accounting for the surrounding environment relaxation was shown to be important up to distances ~ 7 Å. The energy asymmetry and barrier for the detected motifs lied in the ranges 0.5 - 2 meV and 4 - 15 meV, respectively, while their density was about 1 motif per 10 000 atoms. Tuning of motif asymmetry by strain was demonstrated with the coupling coefficient below 1 eV. The tunnel splitting for the symmetrized motifs was estimated on the order of 0.1 meV. The discovered motifs are in good agreement with the available experimental data. The financial support from the Marie Curie Fellowship PIIF-GA-2012-326435 (RespSpatDisp) is gratefully acknowledged.

  14. A Systems-Level Approach to Characterizing Effects of ENMs ...

    Science.gov (United States)

    Engineered nanomaterials (ENMs) represent a new regulatory challenge because of their unique properties and their potential to interact with ecological organisms at various developmental stages, in numerous environmental compartments. Traditional toxicity tests have proven to be unreliable due to their short-term nature and the subtle responses often observed following ENM exposure. In order to fully assess the potential for various ENMs to affect responses in organisms and ecosystems, we are using a systems-level framework to link molecular initiating events with changes in whole-organism responses, and to identify how these changes may translate across scales to disrupt important ecosystem processes. This framework utilizes information from nanoparticle characteristics and exposures to help make linkages across scales. We have used Arabidopsis thaliana as a model organism to identify potential transcriptome changes in response to specific ENMs. In addition, we have focused on plant species of agronomic importance to follow multi-generational changes in physiology and phenology, as well as epigenetic markers to identify possible mechanisms of inheritance. We are employing and developing complementary analytical tools (plasma-based and synchrotron spectroscopies, microscopy, and molecular and stable-isotopic techniques) to follow movement of ENMs and ENM products in plants as they develop. These studies have revealed that changes in gene expression do not a

  15. A system-level model for the microbial regulatory genome.

    Science.gov (United States)

    Brooks, Aaron N; Reiss, David J; Allard, Antoine; Wu, Wei-Ju; Salvanha, Diego M; Plaisier, Christopher L; Chandrasekaran, Sriram; Pan, Min; Kaur, Amardeep; Baliga, Nitin S

    2014-07-15

    Microbes can tailor transcriptional responses to diverse environmental challenges despite having streamlined genomes and a limited number of regulators. Here, we present data-driven models that capture the dynamic interplay of the environment and genome-encoded regulatory programs of two types of prokaryotes: Escherichia coli (a bacterium) and Halobacterium salinarum (an archaeon). The models reveal how the genome-wide distributions of cis-acting gene regulatory elements and the conditional influences of transcription factors at each of those elements encode programs for eliciting a wide array of environment-specific responses. We demonstrate how these programs partition transcriptional regulation of genes within regulons and operons to re-organize gene-gene functional associations in each environment. The models capture fitness-relevant co-regulation by different transcriptional control mechanisms acting across the entire genome, to define a generalized, system-level organizing principle for prokaryotic gene regulatory networks that goes well beyond existing paradigms of gene regulation. An online resource (http://egrin2.systemsbiology.net) has been developed to facilitate multiscale exploration of conditional gene regulation in the two prokaryotes. © 2014 The Authors. Published under the terms of the CC BY 4.0 license.

  16. Low level exposure to chemicals and immune system

    International Nuclear Information System (INIS)

    Colosio, C.; Birindelli, S.; Corsini, E.; Galli, C.L.; Maroni, M.

    2005-01-01

    Industrialized countries are facing an increase of diseases attributable to an alteration of the immune system function, and concern is growing that this trend could be at least partially attributable to new and modified patterns of exposure to chemicals. Among chemicals matter of concern, pesticides can be included. The Authors have reviewed the existing evidence of pesticide immunotoxicity in humans, showing that existing data are inadequate to raise conclusions on the immunotoxic risk related to these compounds. The limits of existing studies are: poor knowledge on exposure levels, heterogeneity of the approach, and difficulty in giving a prognostic significance to the slight changes often observed. To overcome these limits, the Authors have proposed a tier approach, based on three steps: the first, addressed at pointing out a possible immunomodulation; the second, at refining the results and the third one, when needed, to finalize the study and to point out concordance with previous results. Studies should preferably be carried out through comparison of pre- and post-exposure findings in the same groups of subjects to be examined immediately after the end of the exposure. A simplification of the first step approach can be used by the occupational health physician and the occupational toxicologist. Conclusions on the prognostic significance of the slight changes often observed will be reached only by validating the hypothesis generated by field studies with an epidemiological approach. In this field, the most useful option is represented by longitudinal perspective studies

  17. Evidence for systems-level molecular mechanisms of tumorigenesis

    Directory of Open Access Journals (Sweden)

    Capellá Gabriel

    2007-06-01

    Full Text Available Abstract Background Cancer arises from the consecutive acquisition of genetic alterations. Increasing evidence suggests that as a consequence of these alterations, molecular interactions are reprogrammed in the context of highly connected and regulated cellular networks. Coordinated reprogramming would allow the cell to acquire the capabilities for malignant growth. Results Here, we determine the coordinated function of cancer gene products (i.e., proteins encoded by differentially expressed genes in tumors relative to healthy tissue counterparts, hereafter referred to as "CGPs" defined as their topological properties and organization in the interactome network. We show that CGPs are central to information exchange and propagation and that they are specifically organized to promote tumorigenesis. Centrality is identified by both local (degree and global (betweenness and closeness measures, and systematically appears in down-regulated CGPs. Up-regulated CGPs do not consistently exhibit centrality, but both types of cancer products determine the overall integrity of the network structure. In addition to centrality, down-regulated CGPs show topological association that correlates with common biological processes and pathways involved in tumorigenesis. Conclusion Given the current limited coverage of the human interactome, this study proposes that tumorigenesis takes place in a specific and organized way at the molecular systems-level and suggests a model that comprises the precise down-regulation of groups of topologically-associated proteins involved in particular functions, orchestrated with the up-regulation of specific proteins.

  18. Low-level microwave irradiation and central cholinergic systems

    International Nuclear Information System (INIS)

    Lai, H.; Carino, M.A.; Horita, A.; Guy, A.W.

    1989-01-01

    Our previous research showed that 45 min of exposure to low-level, pulsed microwaves (2450-MHz, 2-microseconds pulses, 500 pps, whole-body average specific absorption rate 0.6 W/kg) decreased sodium-dependent high-affinity choline uptake in the frontal cortex and hippocampus of the rat. The effects of microwaves on central cholinergic systems were further investigated in this study. Increases in choline uptake activity in the frontal cortex, hippocampus, and hypothalamus were observed after 20 min of acute microwave exposure, and tolerance to the effect of microwaves developed in the hypothalamus, but not in the frontal cortex and hippocampus, of rats subjected to ten daily 20-min exposure sessions. Furthermore, the effects of acute microwave irradiation on central choline uptake could be blocked by pretreating the animals before exposure with the narcotic antagonist naltrexone. In another series of experiments, rats were exposed to microwaves in ten daily sessions of either 20 or 45 min, and muscarinic cholinergic receptors in different regions of the brain were studied by 3H-QNB binding assay. Decreases in concentration of receptors occurred in the frontal cortex and hippocampus of rats subjected to ten 20-min microwave exposure sessions, whereas increase in receptor concentration occurred in the hippocampus of animals exposed to ten 45-min sessions. This study also investigated the effects of microwave exposure on learning in the radial-arm maze. Rats were trained in the maze to obtain food reinforcements immediately after 20 or 45 min of microwave exposure

  19. A dedicated database system for handling multi-level data in systems biology

    OpenAIRE

    Pornputtapong, Natapol; Wanichthanarak, Kwanjeera; Nilsson, Avlant; Nookaew, Intawat; Nielsen, Jens

    2014-01-01

    Background Advances in high-throughput technologies have enabled extensive generation of multi-level omics data. These data are crucial for systems biology research, though they are complex, heterogeneous, highly dynamic, incomplete and distributed among public databases. This leads to difficulties in data accessibility and often results in errors when data are merged and integrated from varied resources. Therefore, integration and management of systems biological data remain very challenging...

  20. Calculation correlations for radioisotope level gages with relay tracing systems

    International Nuclear Information System (INIS)

    Krejndlin, I.I.; Pakhunkov, Yu.I.

    1978-01-01

    The interrelationship was examined between the operational and instrumental parameters of radioisotope tracking level indicators. The relationships were obtained permitting to check the reliability of the tracking regime, and also of the equilibrium state of the radioisotope tracking level indicator

  1. Efficacy of ciprofloxacin-gentamicin combination therapy in murine bubonic plague.

    Directory of Open Access Journals (Sweden)

    Nadine Lemaître

    Full Text Available Potential benefits of combination antibiotic therapy for the treatment of plague have never been evaluated. We compared the efficacy of a ciprofloxacin (CIN and gentamicin (GEN combination therapy with that of each antibiotic administered alone (i against Yersinia pestis in vitro and (ii in a mouse model of bubonic plague in which animals were intravenously injected with antibiotics for five days, starting at two different times after infection (44 h and 56 h. In vitro, the CIN+GEN combination was synergistic at 0.5x the individual drugs' MICs and indifferent at 1x- or 2x MIC. In vivo, the survival rate for mice treated with CIN+GEN was similar to that observed with CIN alone and slightly higher than that observed for GEN alone 100, 100 and 85%, respectively when treatment was started 44 h post challenge. 100% of survivors were recorded in the CIN+GEN group vs 86 and 83% in the CIN and GEN groups, respectively when treatment was delayed to 56 h post-challenge. However, these differences were not statistically significant. Five days after the end of treatment, Y. pestis were observed in lymph nodes draining the inoculation site (but not in the spleen in surviving mice in each of the three groups. The median lymph node log(10 CFU recovered from persistently infected lymph nodes was significantly higher with GEN than with CIN (5.8 vs. 3.2, p = 0.04 or CIN+GEN (5.8 vs. 2.8, p = 0.01. Taken as the whole, our data show that CIN+GEN combination is as effective as CIN alone but, regimens containing CIN are more effective to eradicate Y. pestis from the draining lymph node than the recommended GEN monotherapy. Moreover, draining lymph nodes may serve as a reservoir for the continued release of Y. pestis into the blood - even after five days of intravenous antibiotic treatment.

  2. Intraoperative utilization of dexamethasone/bupivacaine/gentamicin solution in laparoscopic assisted vaginal hysterectomy and pain management.

    Science.gov (United States)

    Fulcher, Paul H; Granese, Marsha; Chun, Yoon; Welch, Christine A; Seybold, Dara J; Randall, Gary; DePond, R Todd

    2014-01-01

    Adequately controlling pain is a key component of postoperative care after a hysterectomy. The purpose of this study was to evaluate the effects of two intraperitoneal (IP) administered solutions during Laparoscopic Assisted Vaginal Hysterectomy (LAVH), on the amount of postoperative self-administered morphine. In this prospective, randomized, double blinded study, twenty women undergoing LAVH randomly distributed to two treatment groups: (1) 100 ml dexamethasone/ bupivacaine/ gentamicin (DMG) solution: 60 cc injected vaginally at cuff and 40 cc placed topically via laparoscopy over intra-peritoneal postoperative surfaces (IP) and 5 ml bupivacaine or 5 ml saline injected at the laparoscopic incision sites, (2) 100 ml saline solution: 60 cc injected vaginally at cuff and 40 cc placed topically via laparoscopy over intra-peritoneal postoperative surfaces (IP) and 5 ml bupivacaine or 5 ml saline injected at the laparoscopic incision sites. The amount of morphine utilized by the patients was documented from their patient controlled anesthesia (PCA) pump. Patient parameters recorded included perceived pain score, height, weight, age, race, reason for surgery, pre-surgery medications, American Society of Anesthesiologist (ASA) classification, length of the surgery and estimated blood loss (EBL). Age, EBL, length of surgery, and ASA classification were not significantly different between the groups. The postoperative amount of morphine utilized was higher at 4 (p=.02) and 16 hours (p = .04) and tended to be higher at 8, 12 hours (p=.06), and 24 hours (p=.09) in the saline IP group. Overall the saline IP group (n=10) used (median; range) 21.5; 8-82 mg of morphine while the DMG IP group (n=10) used 10.5; 1-23 mg. No participants reported a postoperative infection. This study demonstrates that intraoperative utilization of DMG solution during LAVH enables patients clinically to have less perceived pain and subsequently tend to utilize about half the amount of morphine

  3. International Emission Trading Systems: Trade Level and Political Acceptability

    DEFF Research Database (Denmark)

    Boom, J-T.; Svendsen, Gert Tinggaard

    1999-01-01

    , at the international level, industrial lobbyism was non-significant. Only the 'fossil fuel lobby' played a role. Third, at the national level, one could expect strong political opposition from industry lobbies in case quotas are actually to be distributed at firm level. But trade among countries may benefit industry...

  4. Dynamic systems approaches and levels of analysis in the nervous system

    Science.gov (United States)

    Parker, David; Srivastava, Vipin

    2013-01-01

    Various analyses are applied to physiological signals. While epistemological diversity is necessary to address effects at different levels, there is often a sense of competition between analyses rather than integration. This is evidenced by the differences in the criteria needed to claim understanding in different approaches. In the nervous system, neuronal analyses that attempt to explain network outputs in cellular and synaptic terms are rightly criticized as being insufficient to explain global effects, emergent or otherwise, while higher-level statistical and mathematical analyses can provide quantitative descriptions of outputs but can only hypothesize on their underlying mechanisms. The major gap in neuroscience is arguably our inability to translate what should be seen as complementary effects between levels. We thus ultimately need approaches that allow us to bridge between different spatial and temporal levels. Analytical approaches derived from critical phenomena in the physical sciences are increasingly being applied to physiological systems, including the nervous system, and claim to provide novel insight into physiological mechanisms and opportunities for their control. Analyses of criticality have suggested several important insights that should be considered in cellular analyses. However, there is a mismatch between lower-level neurophysiological approaches and statistical phenomenological analyses that assume that lower-level effects can be abstracted away, which means that these effects are unknown or inaccessible to experimentalists. As a result experimental designs often generate data that is insufficient for analyses of criticality. This review considers the relevance of insights from analyses of criticality to neuronal network analyses, and highlights that to move the analyses forward and close the gap between the theoretical and neurobiological levels, it is necessary to consider that effects at each level are complementary rather than in

  5. Utilization of Health Information System at District Level in Jimma ...

    African Journals Online (AJOL)

    Therefore, in-service training and updating of staff involved in health information system (HIS) at district, strengthening health information system inputs, timely and concrete feedbacks with establishment of functional health management information system (HMIS). KEY WORDS: Health Management Information System, ...

  6. Comparing the standard EQ-5D three-level system with a five-level version

    NARCIS (Netherlands)

    Janssen, Mathieu F.; Birnie, Erwin; Haagsma, Juanita A.; Bonsel, Gouke J.

    2008-01-01

    OBJECTIVES: The aim of this study is a head-to-head comparison of the performance of the three-level EQ-5D (3L) and a newly developed five-level version (5L). METHODS: Eighty-two respondents valued 15 standardized disease descriptions and their own health on three response scales (3L, 5L, and visual

  7. Ideality and Tunneling Level Systems (TLS) in amorphous silicon films.

    Science.gov (United States)

    Hellman, Frances

    Heat capacity, sound velocity, and internal friction of covalently bonded amorphous silicon (a-Si) films with and without hydrogen show that low energy excitations commonly called tunneling or two level systems (TLS) can be tuned over nearly 3 decades, from below detectable limits to the range commonly seen in glassy systems. This tuning is accomplished by growth temperature, thickness, growth rate, light soaking or annealing. We see a strong correlation with atomic density in a-Si and in literature analysis of other glasses, as well as with dangling bond density, sound velocity, and bond angle distribution as measured by Raman spectroscopy, but TLS density varies by orders of magnitude while these other measures of disorder vary by less than a factor of two. The lowest TLS films are grown at temperatures near 0.8 of the theoretical glass transition temperature of Si, similar to work on polymer films and suggestive that the high surface mobility at relatively low temperature of vapor deposition can produce materials close to an ideal glass, with higher density, lower energy, and low TLS due to fewer nearby configurations with similarly low energy. The TLS measured by heat capacity and internal friction are strongly correlated for pure a-Si, but not for hydrogenated a-Si, suggesting that the standard TLS model works for a-Si, but that a-Si:H possess TLS that are decoupled from the acoustic waves measured by internal friction. Internal friction measures those TLS that introduce mechanical damping; we are in the process of measuring low T dielectric loss which yield TLS with dipole moments in order to explore the correlation between different types of TLS. Additionally, a strong correlation is found between an excess T3 term (well above the sound velocity-derived Debye contribution) and the linear term in heat capacity, suggesting a common origin. I thank members of my research group and my collaborators for contributions to this work and NSF-DMR-1508828 for support.

  8. Cefazolin-Gentamicin versus Vancomycin-Ceftazidime Eye Drops for Bacterial Corneal Ulcers; a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Ali-Reza Dehghani

    2009-01-01

    Full Text Available

    PURPOSE: To compare the efficacy of topical cefazolin-gentamicin versus vancomycin-ceftazidime for treatment of bacterial corneal ulcers. METHODS: This randomized double-masked clinical trial was performed on consecutive patients with bacterial corneal ulcers referred to Feiz Hospital, Isfahan, Iran from 2004 to 2005. Patients were randomly assigned to cefazolin-gentamicin or vancomycin-ceftazidime eye drops in a masked fashion. Outcome measures included time for resolution of stromal infiltration, re-epithelization of the epithelial defect, and clearance of anterior chamber inflammation as well as culture results and complications. RESULTS: The study included 89 eyes of 89 patients with bacterial corneal ulcers consisting of 57 (64% male and 32 (36% female subjects. Specimens were culture-negative in 46% of cases. Forty-one eyes received cefazolin-gentamicin and 48 eyes were treated with vancomycin-ceftazidime. Time for resolution of stromal infiltration was 17.7±4.3 days versus 13.8±3.6 days (P=0.04, time to complete re-epithelization was 13.2±3.1 days versus 9.6±2.7 days (P=0.01 and time for clearing of the anterior chamber was 11.6±2.9 days versus 8.1±2.3 days (P

  9. New Train Run Monitoring system: Getting the most out of an ERTMS level 2 Signalling system

    DEFF Research Database (Denmark)

    Richter, Troels; Landex, Alex; Andersen, Jonas Lohmann Elkjær

    . Rail Net Denmark is currently implementing ERTMS Level 2 signalling systems on the entire long distance network and a CBTC signalling system on the Copenhagen Suburban network. It is unlikely, that the current RDS will be able to function in this environment and especially be capable of taking...... advantage of the additional data delivered by the new systems. The conceptual design of a new RDS has consequently been underway since the start of the signalling program. The vision is to create an automatic system that delivers “perfect train run histories” with a cause for every time loss. The future...... ERTMS Traffic Management System will include a rescheduler: Every time a train leaves its path, a rescheduling is triggered and the train receives a new timetable. As a part of this process, other trains may also be rescheduled. A concept for converting this information into the “perfect train run...

  10. A Distributed Approach to System-Level Prognostics

    Data.gov (United States)

    National Aeronautics and Space Administration — Prognostics, which deals with predicting remaining useful life of components, subsystems, and systems, is a key tech- nology for systems health management that leads...

  11. Modeling systems-level dynamics: Understanding without mechanistic explanation in integrative systems biology.

    Science.gov (United States)

    MacLeod, Miles; Nersessian, Nancy J

    2015-02-01

    In this paper we draw upon rich ethnographic data of two systems biology labs to explore the roles of explanation and understanding in large-scale systems modeling. We illustrate practices that depart from the goal of dynamic mechanistic explanation for the sake of more limited modeling goals. These processes use abstract mathematical formulations of bio-molecular interactions and data fitting techniques which we call top-down abstraction to trade away accurate mechanistic accounts of large-scale systems for specific information about aspects of those systems. We characterize these practices as pragmatic responses to the constraints many modelers of large-scale systems face, which in turn generate more limited pragmatic non-mechanistic forms of understanding of systems. These forms aim at knowledge of how to predict system responses in order to manipulate and control some aspects of them. We propose that this analysis of understanding provides a way to interpret what many systems biologists are aiming for in practice when they talk about the objective of a "systems-level understanding." Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. A dedicated database system for handling multi-level data in systems biology.

    Science.gov (United States)

    Pornputtapong, Natapol; Wanichthanarak, Kwanjeera; Nilsson, Avlant; Nookaew, Intawat; Nielsen, Jens

    2014-01-01

    Advances in high-throughput technologies have enabled extensive generation of multi-level omics data. These data are crucial for systems biology research, though they are complex, heterogeneous, highly dynamic, incomplete and distributed among public databases. This leads to difficulties in data accessibility and often results in errors when data are merged and integrated from varied resources. Therefore, integration and management of systems biological data remain very challenging. To overcome this, we designed and developed a dedicated database system that can serve and solve the vital issues in data management and hereby facilitate data integration, modeling and analysis in systems biology within a sole database. In addition, a yeast data repository was implemented as an integrated database environment which is operated by the database system. Two applications were implemented to demonstrate extensibility and utilization of the system. Both illustrate how the user can access the database via the web query function and implemented scripts. These scripts are specific for two sample cases: 1) Detecting the pheromone pathway in protein interaction networks; and 2) Finding metabolic reactions regulated by Snf1 kinase. In this study we present the design of database system which offers an extensible environment to efficiently capture the majority of biological entities and relations encountered in systems biology. Critical functions and control processes were designed and implemented to ensure consistent, efficient, secure and reliable transactions. The two sample cases on the yeast integrated data clearly demonstrate the value of a sole database environment for systems biology research.

  13. Topological structures of adiabatic phase for multi-level quantum systems

    International Nuclear Information System (INIS)

    Liu Zhengxin; Zhou Xiaoting; Liu Xin; Liu Xiongjun; Chen Jingling

    2007-01-01

    The topological properties of adiabatic gauge fields for multi-level (three-level in particular) quantum systems are studied in detail. Similar to the result that the adiabatic gauge field for SU(2) systems (e.g. two-level quantum system or angular momentum systems, etc) has a monopole structure, the curvature 2-forms of the adiabatic holonomies for SU(3) three-level and SU(3) eight-level quantum systems are shown to have monopole-like (for all levels) or instanton-like (for the degenerate levels) structures

  14. Experimental infection with Klebsiella pneumoniae and its gentamicin therapy in guinea pigs 60Co irradiated with 4 Gy

    International Nuclear Information System (INIS)

    Kallay, Z.; Trnovec, T.; Durisova, M.; Mazurova, E.; Navarova, J.; Plskova, M.; Kettner, M.

    1982-01-01

    Sublethal irradiation was used to suppress the immunity response of the organism. Following the development of infection with Klebsiella pneumoniae the therapeutical effect was compared of intramuscular administration and of inhalation of gentamicin. Intramuscular administration was statistically significant for reducing the mortality of infected guinea pigs as against non-treated animals at days 7 to 10 after irradiation. Administration by inhalation had the same effect between days 12 and 25 after irradiation. The weight and blood counts of the animals were observed during the experiment. (M.D.)

  15. LADOTD pavement management system (PMS) for project level applications.

    Science.gov (United States)

    2011-06-01

    To fully address the research needs described in the problem statement, the primary objective of this project is to develop guidelines that provide information on how network level PMS data can be used at a project level in activities of pavement eng...

  16. A System of Systems Approach to Integrating Global Sea Level Change Application Programs

    Science.gov (United States)

    Bambachus, M. J.; Foster, R. S.; Powell, C.; Cole, M.

    2005-12-01

    The global sea level change application community has numerous disparate models used to make predications over various regional and temporal scales. These models have typically been focused on limited sets of data and optimized for specific areas or questions of interest. Increasingly, decision makers at the national, international, and local/regional levels require access to these application data models and want to be able to integrate large disparate data sets, with new ubiquitous sensor data, and use these data across models from multiple sources. These requirements will force the Global Sea Level Change application community to take a new system-of-systems approach to their programs. We present a new technical architecture approach to the global sea level change program that provides external access to the vast stores of global sea level change data, provides a collaboration forum for the discussion and visualization of data, and provides a simulation environment to evaluate decisions. This architectural approach will provide the tools to support multi-disciplinary decision making. A conceptual system of systems approach is needed to address questions around the multiple approaches to tracking and predicting Sea Level Change. A systems of systems approach would include (1) a forum of data providers, modelers, and users, (2) a service oriented architecture including interoperable web services with a backbone of Grid computing capability, and (3) discovery and access functionality to the information developed through this structure. Each of these three areas would be clearly designed to maximize communication, data use for decision making and flexibility and extensibility for evolution of technology and requirements. In contemplating a system-of-systems approach, it is important to highlight common understanding and coordination as foundational to success across the multiple systems. The workflow of science in different applications is often conceptually similar

  17. A High-Throughput, High-Accuracy System-Level Simulation Framework for System on Chips

    Directory of Open Access Journals (Sweden)

    Guanyi Sun

    2011-01-01

    Full Text Available Today's System-on-Chips (SoCs design is extremely challenging because it involves complicated design tradeoffs and heterogeneous design expertise. To explore the large solution space, system architects have to rely on system-level simulators to identify an optimized SoC architecture. In this paper, we propose a system-level simulation framework, System Performance Simulation Implementation Mechanism, or SPSIM. Based on SystemC TLM2.0, the framework consists of an executable SoC model, a simulation tool chain, and a modeling methodology. Compared with the large body of existing research in this area, this work is aimed at delivering a high simulation throughput and, at the same time, guaranteeing a high accuracy on real industrial applications. Integrating the leading TLM techniques, our simulator can attain a simulation speed that is not slower than that of the hardware execution by a factor of 35 on a set of real-world applications. SPSIM incorporates effective timing models, which can achieve a high accuracy after hardware-based calibration. Experimental results on a set of mobile applications proved that the difference between the simulated and measured results of timing performance is within 10%, which in the past can only be attained by cycle-accurate models.

  18. General Tritium Labelling of Gentamicin C by catalytic hydrogen exchange Reaction with Tritiated Water; Marcado general con tritio de la Gentamicina C por intercambio catalitico con agua triatiada

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, C; Diaz, D; Paz, D

    1991-07-01

    Gentamicin C was labelled with tritium by means of a PtO2 catalyzed hydrogen exchange reaction. Under the conditions of the exchange (100 mg of gentamicin, basic form, 0,3 ml H2O-3H, and 50 mg of prereduced PtO2) the radiochemical yield was 0,24, 0,38 and 0,48 % at 120 degree celsius, for 8, 16 and 24 hours respectively. Chemical yield for purified gentamicin was about 60 %. Purification was accomplished with a cellulose column eluted with the lower phase of chloroform-methanol 17 % ammonium hydroxide (2:1:1, v/v) . Chemical purity, determined by HPLC, was 96,5 % and radiochemical one was 95. Main exchange degradation products show biological activity. (Author) 12 refs.

  19. Effect of basic amino acids and aminoglycosides on 3H-gentamicin uptake in cortical slices of rat and human kindney

    International Nuclear Information System (INIS)

    Bennett, W.M.; Plamp, C.E.; Elliott, W.C.; Parker, R.A.; Porter, G.A.

    1982-01-01

    The uptake of 3 H-gentamicin was assessed in renal cortical slices of Fischer 344 male rats and four human cadaver kidneys not utilized for renal transplantation. In both species the uptake was maximal at 90 min and maintained a steady state therafter. The characteristics of the energy-dependent component of 3 H-gentamicin uptake were not altered by various basic amino acids, but competitive inhibition was induced by other aminoglycosides in a dose-dependent fashion. Thus aminoglycosides appear to share a transport process that is distinct from those of organic bases or other cationic substances. In addition, under the experimental conditions employed, the basolateral membranes of the tubular cell is capable of energy-dependent uptake of gentamicin. The role of this route of cellular uptake of aminoglycoside in clinical nephrotoxicity is speculative

  20. original article an innovation systems perspectives on tertiary-level

    African Journals Online (AJOL)

    agricultural education from an innovation systems perspective, an approach ... 5 Sustainable Agriculture, Land and Water, Lancaster Environment Centre ( ... Ethiopia's capacity to leverage science ..... mobilization, project management; and.

  1. Planning Workshop on Local Level Poverty Monitoring System

    International Development Research Centre (IDRC) Digital Library (Canada)

    Md. Abdul Quader - Ranjan Kumar Guha

    decision making and incorporate these in preparing the development plans and programmes of the ... and highlight the usefulness of the information in local level planning. The aim ..... proper accounts of the cooperatives for its sustainability.

  2. Commissioning of the XENON1T liquid level measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Geis, Christopher [Institut fuer Physik, Johannes Gutenberg-Universitaet, Mainz (Germany)

    2016-07-01

    Two-phase xenon time projection chambers (TPCs) have been operated very successfully in direct detection experiments for dark matter. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled with sub-millimeter precision. We present the installation, commissioning and first measurement data of two kinds of level meters operated in the XENON1T TPC: short level meters are three-plated capacitors measuring the level of the liquid-gas interface with a measurement range h∼5 mm and a resolution of ΔC/h∼1 pF/mm. The long level meters are cylindrical double-walled capacitors, measuring the overall filling level of the XENON1T TPC at a measurement range of h=1.4 m and a resolution of ΔC/h∼0.1 pF/mm. Further, we present the design and programming of the readout electronic based on the UTI chip by Smartec, which allows to read all six levelmeters simultaneously.

  3. Abstract Radio Resource Management Framework for System Level Simulations in LTE-A Systems

    DEFF Research Database (Denmark)

    Fotiadis, Panagiotis; Viering, Ingo; Zanier, Paolo

    2014-01-01

    This paper provides a simple mathematical model of different packet scheduling policies in Long Term Evolution- Advanced (LTE-A) systems, by investigating the performance of Proportional Fair (PF) and the generalized cross-Component Carrier scheduler from a theoretical perspective. For that purpose......, an abstract Radio Resource Management (RRM) framework has been developed and tested for different ratios of users with Carrier Aggregation (CA) capabilities. The conducted system level simulations confirm that the proposed model can satisfactorily capture the main properties of the aforementioned scheduling...

  4. A system-level multiprocessor system-on-chip modeling framework

    DEFF Research Database (Denmark)

    Virk, Kashif Munir; Madsen, Jan

    2004-01-01

    We present a system-level modeling framework to model system-on-chips (SoC) consisting of heterogeneous multiprocessors and network-on-chip communication structures in order to enable the developers of today's SoC designs to take advantage of the flexibility and scalability of network-on-chip and...... SoC design. We show how a hand-held multimedia terminal, consisting of JPEG, MP3 and GSM applications, can be modeled as a multiprocessor SoC in our framework....

  5. Update on new medicinal applications of gentamicin: Evidence-based review

    Directory of Open Access Journals (Sweden)

    Changhua Chen

    2014-02-01

    Full Text Available Gentamicin (GM was discovered in 1963 and was introduced into parenteral usage in 1971. Since then, GM has been widely used in medicinal applications. The Food and Drug Administration of the United States approved the routine prescription of GM to treat the following infectious disorders: infection due to Klebsiella pneumoniae, Escherichia coli, Serratia marcescens, Citrobacter spp., Enterobacteriaceae spp., Pseudomonas spp.; Staphylococcus infectious disease; bacterial meningitis; bacterial sepsis of newborns; bacterial septicemia; infection of the eye, bone, skin and/or subcutaneous tissue; infective endocarditis; peritoneal dialysis–associated peritonitis due to Pseudomonas and other gram-negative organisms; peritonitis due to gastrointestinal tract infections; respiratory tract infections; and urinary tract infectious disease. GM is an old antibiotic and is used widely beyond its FDA-labeled indications as follows: actinomycotic infection; Staphylococcus saprophyticus bacteremia with pyelonephritis; appendicitis; cystic fibrosis; diverticulitis; adjunct regimen for febrile neutropenia; female genital infection; uterine infection; postnatal infection; necrotizing enterocolitis in fetus or newborn; osteomyelitis; pelvic inflammatory disease; plague; gonorrhea; tularemia; prophylaxis of post-cholecystectomy infection, transrectal prostate biopsy, and post–tympanostomy-related infection; malignant otitis externa; and intratympanically or transtympanically for Ménière's disease. GM is also used in combination regimens, such as with beta-lactam antibiotics to treat mixed infection and with bacteriophage to treat Staphylococcus aureus infections. It is also added to medical materials, such as GM-loaded cement spacers for osteomyelitis and prosthetic joint–associated infections. Overall, there are many medicinal applications for GM. To reduce the development of GM-resistant bacteria and to maintain its effectiveness, GM should be used

  6. Module-level DC/DC conversion for photovoltaic systems

    NARCIS (Netherlands)

    Bergveld, H.J.; Büthker, D.; Castello, C.; Doorn, T.S.; Jong, de A.; van Otten, R.; Waal, de K.

    2011-01-01

    Photovoltaic (PV) systems are increasingly used to generate electrical energy from solar irradiance incident on PV modules. Each PV module is formed by placing a large amount of PV cells, typically 60, in series. The PV system is then formed by placing a number, typically 10–12, of PV modules in

  7. Determinants of virulence and of resistance to ceftiofur, gentamicin, and spectinomycin in clinical Escherichia coli from broiler chickens in Québec, Canada.

    Science.gov (United States)

    Chalmers, Gabhan; Cormier, Ashley C; Nadeau, Marie; Côté, Geneviève; Reid-Smith, Richard J; Boerlin, Patrick

    2017-05-01

    Antimicrobials are frequently used for the prevention of avian colibacillosis, with gentamicin used for this purpose in Québec until 2003. Ceftiofur was also used similarly, but voluntarily withdrawn in 2005 due to increasing resistance. Spectinomycin-lincomycin was employed as a replacement, but ceftiofur use was partially reinstated in 2007 until its definitive ban by the poultry industry in 2014. Gentamicin resistance frequency increased during the past decade in clinical Escherichia coli isolates from broiler chickens in Québec, despite this antimicrobial no longer being used. Since this increase coincided with the use of spectinomycin-lincomycin, co-selection of gentamicin resistance through spectinomycin was suspected. Therefore, relationships between spectinomycin, gentamicin, and ceftiofur resistance determinants were investigated here. The distribution of 13 avian pathogenic E. coli virulence-associated genes and their association with spectinomycin resistance were also assessed. A sample of 586 E. coli isolates from chickens with colibacillosis in Québec between 2009 and 2013 was used. The major genes identified for resistance to ceftiofur, gentamicin, and spectinomycin were bla CMY , aac(3)-VI, and aadA, respectively. The aadA and aac(3)-VI genes were strongly associated and shown to be located on a modified class 1 integron. The aadA and bla CMY genes were negatively associated, but when present together, were generally located on the same plasmids. No statistical positive association was observed between aadA and virulence genes, and virulence genes were only rarely detected on plasmids encoding spectinomycin resistance. Thus, the use of spectinomycin-lincomycin may likely select for gentamicin but not ceftiofur resistance, nor for any of the virulence-associated genes investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A system-level approach to automation research

    Science.gov (United States)

    Harrison, F. W.; Orlando, N. E.

    1984-01-01

    Automation is the application of self-regulating mechanical and electronic devices to processes that can be accomplished with the human organs of perception, decision, and actuation. The successful application of automation to a system process should reduce man/system interaction and the perceived complexity of the system, or should increase affordability, productivity, quality control, and safety. The expense, time constraints, and risk factors associated with extravehicular activities have led the Automation Technology Branch (ATB), as part of the NASA Automation Research and Technology Program, to investigate the use of robots and teleoperators as automation aids in the context of space operations. The ATB program addresses three major areas: (1) basic research in autonomous operations, (2) human factors research on man-machine interfaces with remote systems, and (3) the integration and analysis of automated systems. This paper reviews the current ATB research in the area of robotics and teleoperators.

  9. System-level tools and reconfigurable computing for next-generation HWIL systems

    Science.gov (United States)

    Stark, Derek; McAulay, Derek; Cantle, Allan J.; Devlin, Malachy

    2001-08-01

    Previous work has been presented on the creation of computing architectures called DIME, which addressed the particular computing demands of hardware in the loop systems. These demands include low latency, high data rates and interfacing. While it is essential to have a capable platform for handling and processing of the data streams, the tools must also complement this so that a system's engineer is able to construct their final system. The paper will present the work in the area of integration of system level design tools, such as MATLAB and SIMULINK, with a reconfigurable computing platform. This will demonstrate how algorithms can be implemented and simulated in a familiar rapid application development environment before they are automatically transposed for downloading directly to the computing platform. This complements the established control tools, which handle the configuration and control of the processing systems leading to a tool suite for system development and implementation. As the development tools have evolved the core-processing platform has also been enhanced. These improved platforms are based on dynamically reconfigurable computing, utilizing FPGA technologies, and parallel processing methods that more than double the performance and data bandwidth capabilities. This offers support for the processing of images in Infrared Scene Projectors with 1024 X 1024 resolutions at 400 Hz frame rates. The processing elements will be using the latest generation of FPGAs, which implies that the presented systems will be rated in terms of Tera (1012) operations per second.

  10. [Endogenous nociceptin level in ischemic stroke: connection to serotonin system].

    Science.gov (United States)

    Tekes, Kornélia; Hantos, Mónika; Bátor, György; Gyenge, Melinda; Laufer, Rudolf; Folyovich, András

    2006-06-01

    Particular role of the heptadecapeptide nociceptin (orphanin FQ), the endogenous agonist of the NOP receptor, has been widely demonstrated in the regulation of pain sensation and anxiety-related behavior. In our best knowledge this is the first study reporting plasma nociceptin levels in 26 acute stroke and 6 transiens ischemic attack (TIA) patients. We have found significantly elevated plasma nociceptin levels in all the three groups of patients studied (stroke influencing the carotis or the lacunar region and TIA). We suggest that elevated plasma nociceptin level is the consequence of stroke as in the group of patients recovered from previous stroke was found similar the control value. Plasma serotonin level was found non-significantly decreased in patients with stroke influencing the lacunar region and TIA patients. However the plasma 5-hydroxy-indoleacetic acid (5HIAA) levels were found significantly elevated in patient groups with stroke influencing both the carotis and the lacunar regions. Data may serve as further evidence for the serotonergic dysregulation in stroke.

  11. Level density of random matrices for decaying systems

    International Nuclear Information System (INIS)

    Haake, F.; Izrailev, F.; Saher, D.; Sommers, H.-J.

    1991-01-01

    Analytical and numerical results for the level density of a certain class of random non-Hermitian matrices H=H+iΓ are presented. The conservative part H belongs to the Gaussian orthogonal ensemble while the damping piece Γ is quadratic in Gaussian random numbers and may describe the decay of resonances through various channels. In the limit of a large matrix dimension the level density assumes a surprisingly simple dependence on the relative strength of the damping and the number of channels. 18 refs.; 4 figs

  12. A Distributed Approach to System-Level Prognostics

    Science.gov (United States)

    2012-09-01

    the end of (useful) life ( EOL ) and/or the remaining useful life (RUL) of components, subsystems, or systems. The prognostics problem itself can be...system state estimate, computes EOL and/or RUL. In this paper, we focus on a model-based prognostics approach (Orchard & Vachtse- vanos, 2009; Daigle...been focused on individual components, and determining their EOL and RUL, e.g., (Orchard & Vachtsevanos, 2009; Saha & Goebel, 2009; Daigle & Goebel

  13. Tank waste remediation system high-level waste vitrification system development and testing requirements

    International Nuclear Information System (INIS)

    Calmus, R.B.

    1995-01-01

    This document provides the fiscal year (FY) 1995 recommended high-level waste melter system development and testing (D and T) requirements. The first phase of melter system testing (FY 1995) will focus on the feasibility of high-temperature operation of recommended high-level waste melter systems. These test requirements will be used to establish the basis for defining detailed testing work scope, cost, and schedules. This document includes a brief summary of the recommended technologies and technical issues associated with each technology. In addition, this document presents the key D and T activities and engineering evaluations to be performed for a particular technology or general melter system support feature. The strategy for testing in Phase 1 (FY 1995) is to pursue testing of the recommended high-temperature technologies, namely the high-temperature, ceramic-lined, joule-heated melter, referred to as the HTCM, and the high-frequency, cold-wall, induction-heated melter, referred to as the cold-crucible melter (CCM). This document provides a detailed description of the FY 1995 D and T needs and requirements relative to each of the high-temperature technologies

  14. Multi-level, automatic file management system using magnetic disk, mass storage system and magnetic tape

    International Nuclear Information System (INIS)

    Fujii, Minoru; Asai, Kiyoshi

    1979-12-01

    A simple, effective file management system using magnetic disk, mass storage system (MSS) and magnetic tape is described. Following are the concepts and techniques introduced in this file management system. (1) File distribution and continuity character of file references are closely approximated by memory retention function. A density function using the memory retention function is thus defined. (2) A method of computing the cost/benefit lines for magnetic disk, MSS and magnetic tape is presented. (3) A decision process of an optimal organization of file facilities incorporating file demands distribution to respective file devices, is presented. (4) A method of simple, practical, effective, automatic file management, incorporating multi-level file management, space management and file migration control, is proposed. (author)

  15. An Innovation Systems Perspectives on Tertiary-Level Agricultural ...

    African Journals Online (AJOL)

    This paper examines how tertiary-level agricultural education in sub-Saharan Africa can contribute to agricultural development beyond its current role as a source of technical training. The paper draws on data and information gathered from semistructured key informant interviews conducted in late 2006 in and around Addis ...

  16. Coding of level of ambiguity within neural systems mediating choice.

    Science.gov (United States)

    Lopez-Paniagua, Dan; Seger, Carol A

    2013-01-01

    Data from previous neuroimaging studies exploring neural activity associated with uncertainty suggest varying levels of activation associated with changing degrees of uncertainty in neural regions that mediate choice behavior. The present study used a novel task that parametrically controlled the amount of information hidden from the subject; levels of uncertainty ranged from full ambiguity (no information about probability of winning) through multiple levels of partial ambiguity, to a condition of risk only (zero ambiguity with full knowledge of the probability of winning). A parametric analysis compared a linear model in which weighting increased as a function of level of ambiguity, and an inverted-U quadratic models in which partial ambiguity conditions were weighted most heavily. Overall we found that risk and all levels of ambiguity recruited a common "fronto-parietal-striatal" network including regions within the dorsolateral prefrontal cortex, intraparietal sulcus, and dorsal striatum. Activation was greatest across these regions and additional anterior and superior prefrontal regions for the quadratic function which most heavily weighs trials with partial ambiguity. These results suggest that the neural regions involved in decision processes do not merely track the absolute degree ambiguity or type of uncertainty (risk vs. ambiguity). Instead, recruitment of prefrontal regions may result from greater degree of difficulty in conditions of partial ambiguity: when information regarding reward probabilities important for decision making is hidden or not easily obtained the subject must engage in a search for tractable information. Additionally, this study identified regions of activity related to the valuation of potential gains associated with stimuli or options (including the orbitofrontal and medial prefrontal cortices and dorsal striatum) and related to winning (including orbitofrontal cortex and ventral striatum).

  17. Multiwall carbon nanotubes chemically modified carbon paste electrodes for determination of gentamicin sulfate in pharmaceutical preparations and biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, M.M., E-mail: magdy_mmagdy@yahoo.com; Abed El-aziz, G.M., E-mail: Gamal_abedelaziz@yahoo.com

    2016-02-01

    This article focused on the construction and characteristics of novel and sensitive gentamicin carbon paste electrodes which are based on the incorporation of multiwall carbon nanotubes (MWCNTs) which improve the characteristics of the electrodes. The electrodes were constructed based on gentamicin-phosphotungstate (GNS-PTA) called CPE{sub 1}, gentamicin-phosphomolybdate (GNS-PMA) called CPE{sub 2}, GNS-PTA + MWMCNTs called MWCPE{sub 1}, and GNS-PMA + MWMCNTs called MWCPE{sub 2}. The constructed electrodes, at optimum paste composition, exhibited good Nernstian response for determination of gentamicin sulfate (GNS) over a linear concentration range from 2.5 × 10{sup −6} to 1 × 10{sup −2}, 3.0 × 10{sup −6} to 1 × 10{sup −2}, 4.9 × 10{sup −7} to 1 × 10{sup −2} and 5.0 × 10{sup −7} to 1 × 10{sup −2} mol L{sup −1}, with lower detection limit 1 × 10{sup −6}, 1 × 10{sup −6}, 1.9 × 10{sup −7} and 2.2 × 10{sup −7} mol L{sup −1}, and with slope values of 29.0 ± 0.4, 29.2 ± 0.7, 31.2 ± 0.5 and 31.0 ± 0.6 mV/decade for CPE{sub 1}, CPE{sub 2}, MWCPE{sub 1} and MWCPE{sub 2}, respectively. The response of electrodes is not affected by pH in the range 3–8 for CPE{sub 1} and CPE{sub 2} and in the range 2.5–8.5 for MWCPE{sub 1} and MWCPE{sub 2}. The results showed fast dynamic response time (about 8–5 s) and long lifetime (more than 2 months) for all electrodes. The sensors showed high selectivity for gentamicin sulfate (GNS) with respect to a large number of interfering species. The constructed electrodes were successfully applied for determination of GNS in pure form, its pharmaceutical preparations and biological fluids using standard addition and potentiometric titration methods with high accuracy and precision. - Graphical abstract: The incorporation of MWCNTs in paste composition improves the characteristics of the MWCPE electrodes which show better responses in terms of sensitivity, Nernstian slope, linear range, faster

  18. Is the Level of Student Academic Performance in Tennessee Public School Systems Related to Level of Expenditures for School Systems?

    Science.gov (United States)

    Leuthold, Frank O.

    The 1992 Tennessee Education Improvement Act resulted from a successful law suit by smaller and poorer school systems in Tennessee concerning equity of funding. The Act established the Basic Education Program (BEP), which increased the state sales tax rate, shifted state funds from better funded to poorer school systems, and required systematic…

  19. Study on a quantitative evaluation method of equipment maintenance level and plant safety level for giant complex plant system

    International Nuclear Information System (INIS)

    Aoki, Takayuki

    2010-01-01

    In this study, a quantitative method on maintenance level which is determined by the two factors, maintenance plan and field work implementation ability by maintenance crew is discussed. And also a quantitative evaluation method on safety level for giant complex plant system is discussed. As a result of consideration, the following results were obtained. (1) It was considered that equipment condition after maintenance work was determined by the two factors, maintenance plan and field work implementation ability possessed by maintenance crew. The equipment condition determined by the two factors was named as 'equipment maintenance level' and its quantitative evaluation method was clarified. (2) It was considered that CDF in a nuclear power plant, evaluated by using a failure rate counting the above maintenance level was quite different from CDF evaluated by using existing failure rates including a safety margin. Then, the former CDF was named as 'plant safety level' of plant system and its quantitative evaluation method was clarified. (3) Enhancing equipment maintenance level means an improvement of maintenance quality. That results in the enhancement of plant safety level. Therefore, plant safety level should be always watched as a plant performance indicator. (author)

  20. Franson Interference Generated by a Two-Level System

    Science.gov (United States)

    Peiris, M.; Konthasinghe, K.; Muller, A.

    2017-01-01

    We report a Franson interferometry experiment based on correlated photon pairs generated via frequency-filtered scattered light from a near-resonantly driven two-level semiconductor quantum dot. In contrast to spontaneous parametric down-conversion and four-wave mixing, this approach can produce single pairs of correlated photons. We have measured a Franson visibility as high as 66%, which goes beyond the classical limit of 50% and approaches the limit of violation of Bell's inequalities (70.7%).

  1. Regulatory networks, legal federalism, and multi-level regulatory systems

    OpenAIRE

    Kerber, Wolfgang; Wendel, Julia

    2016-01-01

    Transnational regulatory networks play important roles in multi-level regulatory regimes, as e.g, the European Union. In this paper we analyze the role of regulatory networks from the perspective of the economic theory of legal federalism. Often sophisticated intermediate institutional solutions between pure centralisation and pure decentralisation can help to solve complex tradeoff problems between the benefits and problems of centralised and decentralised solutions. Drawing upon the insight...

  2. Mechanical guided waves for fuel level monitoring system

    Directory of Open Access Journals (Sweden)

    Tiberiu Adrian SALAORU

    2017-09-01

    Full Text Available The mechanical guided waves have a wide range of applications in many types of equipment and devices. The fuel level is an important parameter which needs to be monitored for a vehicle which can be a space vehicle, an aircraft or any other. For this purpose mechanical guided waves can be used as they have several major advantages over any other methods. There are a wide ultrasonic sensors used for this purpose but in the most cases the mechanical waves are traveling through air or fuel for measuring their level. In general the wave propagation through a single media at a time is utilized. The method described in this work uses the propagation of the mechanical guided waves through two different media in the same time. The propagating media is the container wall and the other is the fuel. One of the advantages of this method is the reduction of the measurement errors when the incident angle to the fuel level surface is different from 90 degree. These situations could occur when the fuel tank is tilted or when the fuel surface is not flat. This measurement method will not be affected by these conditions.

  3. NASA: A generic infrastructure for system-level MP-SoC design space exploration

    NARCIS (Netherlands)

    Jia, Z.J.; Pimentel, A.D.; Thompson, M.; Bautista, T.; Núñez, A.

    2010-01-01

    System-level simulation and design space exploration (DSE) are key ingredients for the design of multiprocessor system-on-chip (MP-SoC) based embedded systems. The efforts in this area, however, typically use ad-hoc software infrastructures to facilitate and support the system-level DSE experiments.

  4. Exploiting Domain Knowledge in System-level MPSoC Design Space Exploration

    NARCIS (Netherlands)

    Thompson, M.; Pimentel, A.D.

    2013-01-01

    System-level design space exploration (DSE), which is performed early in the design process, is of eminent importance to the design of complex multi-processor embedded multimedia systems. During system-level DSE, system parameters like, e.g., the number and type of processors, and the mapping of

  5. Design space pruning through hybrid analysis in system-level design space exploration

    NARCIS (Netherlands)

    Piscitelli, R.; Pimentel, A.D.

    2012-01-01

    System-level design space exploration (DSE), which is performed early in the design process, is of eminent importance to the design of complex multi-processor embedded system archi- tectures. During system-level DSE, system parameters like, e.g., the number and type of processors, the type and size

  6. Interleaving methods for hybrid system-level MPSoC design space exploration

    NARCIS (Netherlands)

    Piscitelli, R.; Pimentel, A.D.; McAllister, J.; Bhattacharyya, S.

    2012-01-01

    System-level design space exploration (DSE), which is performed early in the design process, is of eminent importance to the design of complex multi-processor embedded system architectures. During system-level DSE, system parameters like, e.g., the number and type of processors, the type and size of

  7. Pruning techniques for multi-objective system-level design space exploration

    NARCIS (Netherlands)

    Piscitelli, R.

    2014-01-01

    System-level design space exploration (DSE), which is performed early in the design process, is of eminent importance to the design of complex multi-processor embedded system architectures. During system-level DSE, system parameters like, e.g., the number and type of processors, the type and size of

  8. Electronic system level design an open-source approach

    CERN Document Server

    Rigo, Sandro; Santos, Luiz

    2014-01-01

    This book devises ESL design from the pragmatic perspective of a SystemC-based representation by showing how to build and how to use ESL languages, models and tools. It includes TLM 2.0 and step-by-step examples; it also addresses power modeling.

  9. Integrating Space Systems Operations at the Marine Expeditionary Force Level

    Science.gov (United States)

    2015-06-01

    Operation ARSST Army Space Support Team BCT Brigade Combat Team BDA Battle Damage Assessment BLOS Beyond Line of Site C2 Command and Control CMCC-CP...accurate imagery of known target locations. Additionally, ISR systems provide a convenient battle damage assessment ( BDA ) option necessary to determine

  10. Bacterial levels in the Nyl River system, Limpopo province, South ...

    African Journals Online (AJOL)

    Heterotrophic plate counts, faecal coliform counts and total coliform counts indicated that the system was stressed. The Modimolle sewage treatment works and local agricultural activities were found to be the point and diffuse sources of bacterial contamination, respectively. African Journal of Aquatic Science 2010, 35(1): ...

  11. Automated Design of Board and MCM Level Digital Systems.

    Science.gov (United States)

    1997-10-01

    Object- Oriented Programming, 7(6):39-49, October 1994. 46 December 14, 1994 33 [3] Stephen J. Garland, John V. Guttag, and James J. Horning...of Digital Circuits. Mc Graw Hill, 1994. 15 APPENDIX G: ... 93 Multicomponent Partitioning for VLSI System Synthesis Nand Kumar and Ranga Vemuri

  12. PRAXIS, High Level Computer Language for System Applications

    International Nuclear Information System (INIS)

    Holloway, F.W.

    1998-01-01

    1 - Description of program or function: PRAXIS is a systems implementation programming language designed especially for control and communications programming. It is a modern, strongly-typed, block-structured language similar to PASCAL but with extensions and features particular to control systems applications. The software consists of three PRAXIS compilers and three associated support utilities - the PRAXIS RMS-11 Interface, a set of procedures, functions, and type declarations which allow PRAXIS programs to interface to the RMS-11 Input/Output system under VAX/VMS and the RSX-11M systems; TEXTIO, character I/O software for terminal and line-printer text operations; and UNPASCAL, a program which translates simple PASCAL programs into PRAXIS. The compilers included are: a VAX/VMS version which generates VAX code, a VAX/VMS version which generates PDP11 codes, and a PDP11/RSX-11M version which generates PDP11 code. NESC Edition B of PRAXIS is designated as Version 7.3 by the contributors. The PDP11 compiler is not supported and has not been changed since February 1982. 2 - Method of solution: The PRAXIS compilers use LALR parsing technique to generate an intermediate machine-independent code. This is then processed using templates for the target computer to generate actual machine instructions

  13. System-Level Design Considerations for Carbon Nanotube Electromechanical Resonators

    Directory of Open Access Journals (Sweden)

    Christian Kauth

    2013-01-01

    Full Text Available Despite an evermore complete plethora of complex domain-specific semiempirical models, no succinct recipe for large-scale carbon nanotube electromechanical systems design has been formulated. To combine the benefits of these highly sensitive miniaturized mechanical sensors with the vast functionalities available in electronics, we identify a reduced key parameter set of carbon nanotube properties, nanoelectromechanical system design, and operation that steers the sensor’s performance towards system applications, based on open- and closed-loop topologies. Suspended single-walled carbon nanotubes are reviewed in terms of their electromechanical properties with the objective of evaluating orders of magnitude of the electrical actuation and detection mechanisms. Open-loop time-averaging and 1ω or 2ω mixing methods are completed by a new 4ω actuation and detection technique. A discussion on their extension to closed-loop topologies and system applications concludes the analysis, covering signal-to-noise ratio, and the capability to spectrally isolate the motional information from parasitical feedthrough by contemporary electronic read-out techniques.

  14. Systems of transversal sections near critical energy levels of hamiltonian systems in $Mathbb{R}^{4}$

    CERN Document Server

    de, Naiara V

    2018-01-01

    In this article the authors study Hamiltonian flows associated to smooth functions H:\\mathbb R^4 \\to \\mathbb R restricted to energy levels close to critical levels. They assume the existence of a saddle-center equilibrium point p_c in the zero energy level H^{-1}(0). The Hamiltonian function near p_c is assumed to satisfy Moser's normal form and p_c is assumed to lie in a strictly convex singular subset S_0 of H^{-1}(0). Then for all E \\gt 0 small, the energy level H^{-1}(E) contains a subset S_E near S_0, diffeomorphic to the closed 3-ball, which admits a system of transversal sections \\mathcal F_E, called a 2-3 foliation. \\mathcal F_E is a singular foliation of S_E and contains two periodic orbits P_2,E\\subset \\partial S_E and P_3,E\\subset S_E\\setminus \\partial S_E as binding orbits. P_2,E is the Lyapunoff orbit lying in the center manifold of p_c, has Conley-Zehnder index 2 and spans two rigid planes in \\partial S_E. P_3,E has Conley-Zehnder index 3 and spans a one parameter family of planes in S_E \\setmin...

  15. Study on application of adaptive fuzzy control and neural network in the automatic leveling system

    Science.gov (United States)

    Xu, Xiping; Zhao, Zizhao; Lan, Weiyong; Sha, Lei; Qian, Cheng

    2015-04-01

    This paper discusses the adaptive fuzzy control and neural network BP algorithm in large flat automatic leveling control system application. The purpose is to develop a measurement system with a flat quick leveling, Make the installation on the leveling system of measurement with tablet, to be able to achieve a level in precision measurement work quickly, improve the efficiency of the precision measurement. This paper focuses on the automatic leveling system analysis based on fuzzy controller, Use of the method of combining fuzzy controller and BP neural network, using BP algorithm improve the experience rules .Construct an adaptive fuzzy control system. Meanwhile the learning rate of the BP algorithm has also been run-rate adjusted to accelerate convergence. The simulation results show that the proposed control method can effectively improve the leveling precision of automatic leveling system and shorten the time of leveling.

  16. Development of low level alpha particle counting system

    International Nuclear Information System (INIS)

    Minobe, Masao; Kondo, Hiraku; Chinuki, Takashi; Hirano, Hiromichi

    1987-01-01

    Much attention has been paid to the trace analysis of uranium and thorium contained in the base material of LSI or VLSI, since the so-called ''soft-error'' of the memory device was known to be due to alpha particles emitted from these radioactive elements. We have developed an apparatus to meet the needs of estimating such a very small quantity of U and Th of the level of ppb, by directly counting alpha particles using a gas-flow type proportional counter. This method requires no sophisticated analytical skill, and the accuracy of the result is satisfactory. The instrumentation and some application of this apparatus are described. (author)

  17. Four-level systems and a universal quantum gate

    Energy Technology Data Exchange (ETDEWEB)

    Baldiotti, M.C.; Gitman, D.M. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, S.P. (Brazil)

    2008-07-15

    We discuss the possibility of implementing a universal quantum XOR gate by using two coupled quantum dots subject to external magnetic fields that are parallel and slightly different. We consider this system in two different field configurations. In the first case, parallel external fields with the intensity difference at each spin being proportional to the time-dependent interaction between the spins. A general exact solution describing this system is presented and analyzed to adjust field parameters. Then we consider parallel fields with intensity difference at each spin being constant and the interaction between the spins switching on and off adiabatically. In both cases we adjust characteristics of the external fields (their intensities and duration) in order to have the parallel pulse adequate for constructing the XOR gate. In order to provide a complete theoretical description of all the cases, we derive relations between the spin interaction, the inter-dot distance, and the external field. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  18. System level permeability modeling of porous hydrogen storage materials.

    Energy Technology Data Exchange (ETDEWEB)

    Kanouff, Michael P.; Dedrick, Daniel E.; Voskuilen, Tyler (Purdue University, West Lafayette, IN)

    2010-01-01

    A permeability model for hydrogen transport in a porous material is successfully applied to both laboratory-scale and vehicle-scale sodium alanate hydrogen storage systems. The use of a Knudsen number dependent relationship for permeability of the material in conjunction with a constant area fraction channeling model is shown to accurately predict hydrogen flow through the reactors. Generally applicable model parameters were obtained by numerically fitting experimental measurements from reactors of different sizes and aspect ratios. The degree of channeling was experimentally determined from the measurements and found to be 2.08% of total cross-sectional area. Use of this constant area channeling model and the Knudsen dependent Young & Todd permeability model allows for accurate prediction of the hydrogen uptake performance of full-scale sodium alanate and similar metal hydride systems.

  19. A real-time high level trigger system for CALIFA

    Energy Technology Data Exchange (ETDEWEB)

    Gernhaeuser, Roman; Heiss, Benjamin; Klenze, Philipp; Remmels, Patrick; Winkel, Max [Physik Department, Technische Universitaet Muenchen (Germany)

    2016-07-01

    The CALIFA calorimeter with its about 2600 scintillator crystals is a key component of the R{sup 3}B setup. For many experiments CALIFA will have to perform complex trigger decisions depending on the total energy deposition, γ multiplicities or geometrical patterns with a minimal latency. This selection is an essential tool for the accurate preselection of relevant events and provides a significant data reduction. The challenge is to aggregate local trigger information from up to 200 readout modules. The trigger tree transport protocol (T{sup 3}P) will use dedicated FPGA boards and bus systems to collect trigger information and perform hierarchical summations to ensure a trigger decision within 1 μs. The basic concept and implementation of T{sup 3}P are presented together with first tests on a prototype system.

  20. Managerial competence at senior levels of integrated delivery systems.

    Science.gov (United States)

    Longest, B B

    1998-01-01

    The advent of integrated delivery systems (IDSs) in the healthcare industry has changed much about the work involved in running many healthcare organizations. As a result of these changes, senior healthcare managers in IDSs need different skills and knowledge (competencies) than managers of other healthcare systems. The work of managers is changed by the shift to more organizational integration in the healthcare industry because they become responsible for coordinated continuation of services, accountable for the overall health status of the populations they serve, and involved in more complex organizational structures. The article identifies six distinct managerial competencies--conceptual, technical managerial/clinical, interpersonal/collaborative, political, commercial, and governance--and describes how they relate to an IDS senior manager's successful work performance. The implications of these competencies are considered for practicing senior managers in IDSs, as well as those who aspire to such positions, and those who help educate them.