WorldWideScience

Sample records for system-1 fds-1 assessment

  1. Probabilistic safety assessment of the dual-cooled waste transmutation blanket for the FDS-I

    International Nuclear Information System (INIS)

    Hu, L.; Wu, Y.

    2006-01-01

    The subcritical dual-cooled waste transmutation (DWT) blanket is one of the key components of fusion-driven subcritical system (FDS-I). The probabilistic safety assessment (PSA) can provide valuable information on safety characteristics of FDS-I to give recommendations for the optimization of the blanket concepts and the improvement of the design. Event tree method has been adopted to probabilistically analyze the safety of the DWT blanket for FDS-I using the home-developed PSA code RiskA. The blanket melting frequency has been calculated and compared with the core melting frequencies of PWRs and a fast reactor. Sensitivity analysis of the safety systems has been performed. The results show that the current preliminary design of the FDS-I is very attractive in safety

  2. Conceptual design of the fusion-driven subcritical system FDS-I

    International Nuclear Information System (INIS)

    Wu, Y.; Zheng, S.; Zhu, X.; Wang, W.; Wang, H.; Liu, S.; Bai, Y.; Chen, H.; Hu, L.; Chen, M.; Huang, Q.; Huang, D.; Zhang, S.; Li, J.; Chu, D.; Jiang, J.; Song, Y.

    2006-01-01

    The fusion-driven subcritical system (named FDS-I) was previously proposed as an intermediate step toward the final application of fusion energy. A conceptual design of the FDS-I is presented, which consists of the fusion neutron driver with relatively easy-achieved plasma parameters, and the He-gas/liquid lithium-lead Dual-cooled subcritical Waste Transmutation (DWT) blanket used to transmute long-lived radioactive wastes and to generate energy on the basis of self-sustainable fission and fusion fuel cycle. An overview of the FDS-I is given and the specifications of the design analysis are summarized

  3. Preliminary analysis of typical transients in fusion driven subcritical system (FDS-I)

    International Nuclear Information System (INIS)

    Bai Yunqing; Ke Yan; Wu Yican

    2007-01-01

    The potential safety characteristic is expected as one of the advantages of fusion-driven subcritical system (FDS-I) for the transmutation and incineration of nuclear waste compared with the critical reactor. Transients of the FDS-I may occur due to the perturbation of external neutron source, the failure of functional device, and the occurrence of the uncontrolled event. As typical transient scenarios, the following cases were analyzed: unprotected plasma overpower (UPOP), unprotected loss of flow (ULOF), unprotected transient overpower (UTOP). The transient analyses for the FDS-I were performed with a coupled two-dimensional thermal-hydraulics and neutronics transient analysis code NTC2D. The negative feedback of reactivity is the interesting safety feature of FDS-I as temperature increase, due to the fuel form of the circulating particle. The present simulation results showed that the current FDS-I design has a resistance against severe transient scenarios. (author)

  4. On fusion driven systems (FDS) for transmutation

    Energy Technology Data Exchange (ETDEWEB)

    Aagren, O (Uppsala Univ., Aangstroem laboratory, div. of electricity, Uppsala (Sweden)); Moiseenko, V.E. (Inst. of Plasma Physics, National Science Center, Kharkov Inst. of Physics and Technology, Kharkov (Ukraine)); Noack, K. (Forschungszentrum Dresden-Rossendorf (Germany))

    2008-10-15

    This report gives a brief description of ongoing activities on fusion driven systems (FDS) for transmutation of the long-lived radioactive isotopes in the spent nuclear waste from fission reactors. Driven subcritical systems appears to be the only option for efficient minor actinide burning. Driven systems offer a possibility to increase reactor safety margins. A comparatively simple fusion device could be sufficient for a fusion-fission machine, and transmutation may become the first industrial application of fusion. Some alternative schemes to create strong fusion neutron fluxes are presented

  5. On fusion driven systems (FDS) for transmutation

    International Nuclear Information System (INIS)

    Aagren, O; Moiseenko, V.E.; Noack, K.

    2008-10-01

    This report gives a brief description of ongoing activities on fusion driven systems (FDS) for transmutation of the long-lived radioactive isotopes in the spent nuclear waste from fission reactors. Driven subcritical systems appears to be the only option for efficient minor actinide burning. Driven systems offer a possibility to increase reactor safety margins. A comparatively simple fusion device could be sufficient for a fusion-fission machine, and transmutation may become the first industrial application of fusion. Some alternative schemes to create strong fusion neutron fluxes are presented

  6. Activation analysis and waste management for blanket materials of multi-functional experimental fusion–fission hybrid reactor (FDS-MFX)

    International Nuclear Information System (INIS)

    Jiang, Jieqiong; Yuan, Baoxin; Zou, Jun; Wu, Yican

    2014-01-01

    The preliminary studies of the activation analysis and waste management for blanket materials of the multi-functional experimental fusion–fission hybrid reactor, i.e. Multi-Functional eXperimental Fusion Driven Subcritical system named FDS-MFX, were performed. The neutron flux of the FDS-MFX blanket was calculated using VisualBUS code and Hybrid Evaluated Nuclear Data Library (HENDL) developed by FDS Team. Based on these calculated neutron fluxes, the activation properties of blanket materials were analyzed by the induced radioactivity, the decay heat and the contact dose rate for different regions of the FDS-MFX blanket. The safety and environment assessment of fusion power (SEAFP) strategy, which was developed in Europe, was applied to FDS-MFX blanket for the management of activated materials. Accordingly, the classification and management strategy of activated materials after different cooling time were proposed for FDS-MFX blanket

  7. Cinema Fire Modelling by FDS

    International Nuclear Information System (INIS)

    Glasa, J; Valasek, L; Weisenpacher, P; Halada, L

    2013-01-01

    Recent advances in computer fluid dynamics (CFD) and rapid increase of computational power of current computers have led to the development of CFD models capable to describe fire in complex geometries incorporating a wide variety of physical phenomena related to fire. In this paper, we demonstrate the use of Fire Dynamics Simulator (FDS) for cinema fire modelling. FDS is an advanced CFD system intended for simulation of the fire and smoke spread and prediction of thermal flows, toxic substances concentrations and other relevant parameters of fire. The course of fire in a cinema hall is described focusing on related safety risks. Fire properties of flammable materials used in the simulation were determined by laboratory measurements and validated by fire tests and computer simulations

  8. Cinema Fire Modelling by FDS

    Science.gov (United States)

    Glasa, J.; Valasek, L.; Weisenpacher, P.; Halada, L.

    2013-02-01

    Recent advances in computer fluid dynamics (CFD) and rapid increase of computational power of current computers have led to the development of CFD models capable to describe fire in complex geometries incorporating a wide variety of physical phenomena related to fire. In this paper, we demonstrate the use of Fire Dynamics Simulator (FDS) for cinema fire modelling. FDS is an advanced CFD system intended for simulation of the fire and smoke spread and prediction of thermal flows, toxic substances concentrations and other relevant parameters of fire. The course of fire in a cinema hall is described focusing on related safety risks. Fire properties of flammable materials used in the simulation were determined by laboratory measurements and validated by fire tests and computer simulations

  9. The Feasibility of Multiscale Modeling of Tunnel Fires Using FDS 6

    DEFF Research Database (Denmark)

    Vermesi, Izabella; Colella, Francesco; Rein, Guillermo

    2014-01-01

    The HVAC component of FDS 6 was used to divide a 1.2km tunnel into a 3D near fire area and a 1D area further away from the fire in order to investigate the feasibility of multiscale modeling of tunnel fires with this new feature in FDS. The two sub-models were coupled directly. The results were...... compared with reference works on multiscale modeling and the outcome is considered positive, with a deviation of less than 5% in magnitude of relevant parameters, yet with a significant reduction of the simulation runtime. As such, the multiscale method is deemed feasible for simulating tunnel fires in FDS......6. However, the simplifications that are made in this work require further investigation in order to take full advantage of the potential of this computational method. INTRODUCTION Multiscale modeling for tunnel flows and fires has previously been studied using RANS general purpose CFD software...

  10. Marine Tactical Command and Control System (MTACCS) Field Development System-1 (FDS-1) assessment: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Avery, L.W.; Hunt, S.T.; Savage, S.F. (Pacific Northwest Lab., Richland, WA (United States)); McLaughlin, P.D.; Shepdard, A.P.; Worl, J.C. (Battelle Seattle Research Center, WA (United States))

    1992-04-01

    The United State Marine Corps (USMC) is continuing the development and fielding of the Marine Corps Tactical Command and Control System (MTACCS), a system which exists in varying states of development, fielding, or modernization. MTACCS is currently composed of the following components: Tactical Combat Operations System (TCO) for ground command and control (C2), Intelligence Analysis System (IAS) with a Genser terminal connected to a TCO workstation for intelligence C2, Marine Integrated Personnel System (MIPS) and a TCO workstation using the Marine Combat Personnel System (MCPERS) software for personnel C2, Marine Integrated Logistics System (MILOGS) which is composed of the Landing Force Asset Distribution System (LFADS), the Marine Air-Ground Task Force (MAGTF) II, and a TCO terminal using the Marine Combat Logistics System (MCLOG) for logistics C2, Marine Corps Fire Support System (MCFSS) for fire support C2, and Advanced Tactical Air Command Central (ATACC) and the Improved Direct Air Support Central for aviation C2.

  11. Conceptual design of China fusion power plant FDS-II

    International Nuclear Information System (INIS)

    Wu, Y.; Liu, S.; Chen, H.

    2007-01-01

    As one of the series of fusion system design concepts developed by the FDS Team of China, FDS-II is designated to exploit and evaluate potential attractiveness of fusion energy application for the generation of electricity on the basis of conservatively advanced plasma parameters, which can be limitedly extrapolated from the successful operation of ITER. The principle of the blanket design is established in both the feasibility and potential attractiveness of technology to meet the requirement for tritium self-sufficiency, safety margin, operation economy and environment protection etc. The plasma physics and engineering parameters of FDS-II are selected on the basis of the progress in recent experiments and associated theoretical studies of magnetic confinement fusion plasma with a fusion power of 2∝3 GW. The neutron wall load of 2∝3 MW/m 2 and the surface heat flux of 0.5∝1 MW/m 2 are considered for high effective power conversion. The ''multi-modules'' scenario is adopted in the FDS-II blanket design to reduce thermal stress and electromagnetic forces under plasma disruption, with liquid metal lithium lead (LiPb) as tritium breeder, the Reduced Activation Ferritic/Martensitic (RAFM) steel as structural material. Two options of specific liquid LiPb blanket concepts have been proposed, named the Dual-cooled Lithium Lead (DLL) breeder blanket and the Quasi-Static Lithium Lead (SLL) breeder blanket. The DLL blanket is a dual-cooled LiPb breeder system with helium gas to cool the first wall and main structure and LiPb eutectic to be self-cooled. The flow channel inserts (FCIs), e.g. SiCf/SiC composites, are designed as the thermal and electrical insulators inside the LiPb flow channels to reduce the magnetohydrodynamic (MHD) pressure drop and to allow the coolant LiPb outlet temperature up to 700 C for high thermal efficiency. The SLL blanket is another option of the FDS-II blanket with the technology developed relatively easily. To avoid or mitigate the

  12. Infection Imaging With 18F-FDS and First-in-Human Evaluation

    International Nuclear Information System (INIS)

    Yao, Shaobo; Xing, Haiqun; Zhu, Wenjia; Wu, Zhanhong; Zhang, Yingqiang; Ma, Yanru; Liu, Yimin; Huo, Li; Zhu, Zhaohui; Li, Zibo; Li, Fang

    2016-01-01

    Purpose: The noninvasive imaging of bacterial infections is critical in order to reduce mortality and morbidity caused by these diseases. The recently reported 18 F-FDS ( 18 F-2-fluorodeoxy sorbitol) as a PET (positron emission tomography) tracer can be used to image Enterobacteriaceae-specific infections and provides a potential alternative to this problem compared with other probes for imaging infections. In this study, automatic synthesis, validation of 18 F-FDS and a first-in-human study were performed and discussed. Methods: A multifunctional synthesis module was employed for the radiosynthesis of 18 F-FDG ( 18 F-2-fluorodeoxy glucose) and 18 F-FDS starting from 18 F ion using two-pot three-step fully automated reactions. The behavior of 18 F-FDS as an in vivo imaging probe for infections was evaluated in an Escherichia coli mouse infection model. The first detailed pharmacokinetic and biodistribution parameters were obtained from healthy human volunteers. Results: The uptake of 18 F-FDS in an E. coli mouse-myositis infection model was easily differentiated from other organs and normal muscle. Intensive lesion uptake declined after antibiotic treatment. In the pilot human study, no adverse effects due to 18 F-FDS were observed up to 24 h post-injection. The radiotracer was rapidly cleared from the circulation and excreted mainly through the urinary system. Conclusion: We conclude that 18 F-FDS PET holds great potential for appropriate and effective for the imaging of bacterial infections in vivo. These preliminary results indicate that further clinical studies are warranted.

  13. The numerical comparison of fire combustion model and water-mist suppression with experiments by FDS code

    International Nuclear Information System (INIS)

    Li Hsuennien; Ferng Yuhming; Shih Chunkuan; Hsu Wensheng

    2007-01-01

    FDS [1] code numerically solves a form of the Navier-Stokes equations appropriate for low-speed, thermally driven flow with an emphasis on smoke and heat transport from fires. FDS uses a mixture fraction combustion model. The mixture fraction is a conserved scalar quantity that is defined as the fraction of fuel gas at a given point in the flow field. The model assumes that combustion is mixing-controlled, and that the reaction of fuel and oxygen is infinitely fast. In FDS, Lagrangian particles are used to simulate smoke movement and sprinkling water-mist discharge. In order to evaluate the combustion model and water-mist suppression function of the code, FDS analyses are conducted to simulate two enclosure fire cases available in the literature. Comparisons with other combustion models are also made. For fires suppression by water-mist in FDS, parametric studies are performed to compare various water-mist injection characteristics for maximum suppression. Numerical results indicate that the flame suppression is closely related to characteristics of the water mist, such as droplet diameter, mist injection velocity, injection density. Our present investigations show that the combustion model and water-mist suppression in FDS can provide simulation results that are comparable with the experiments. (author)

  14. Research and development issues for fast reactor structural design standard (FDS)

    International Nuclear Information System (INIS)

    Kasahara, Naoto; Ando, Masanori; Morishita, Masaki

    2003-01-01

    For realization of safe and economical fast reactor (FR) plants, Japan Nuclear Cycle Development Institute (JNC) and Japan Atomic Power Company (JAPC) are cooperating on 'Feasibility Study on Commercialized FR Cycle Systems'. To certify the design concepts and validate their structural integrity, the research and development of 'Fast Reactor Structural Design Standard (FDS)' is recognized as an essential theme. FDS considers general characteristics of FRs and design needs for their rationalization. Three main subjects were settled in research and development issues of FDS. One is rationalization of failure criteria' taking characteristic design conditions into account. Next is development of 'a guideline on inelastic analysis for design' in order to predict elastic plastic and creep behaviours of high temperature components. Furthermore, efforts are being made toward preparing a guideline on thermal loads modeling' for FR component design where thermal loads are dominant. (author)

  15. FDS5 Simulation of PRISME INTEGRAL Test, PRSINT4

    International Nuclear Information System (INIS)

    Park, Jong Seok

    2012-01-01

    The reliance on fire modeling has playing a key role in the risk-informed and performance-based fire protection field. The ability to accurately predict fire behavior using the fire models is of high utility for hazard assessment, investigations and performance based design. Validation is the process of determining the degree of agreement between fire model outputs and real world events for one or more results of interest. The goal of validation is to quantify confidence in the predictive capability of the model. Validation in NUREG-1824 entails comparing the model prediction with full-scale fire experiments and quantifying the results. The objectives of this study, focused on the fire model validation, are to compare the FDS5 prediction results with the PRISME INTEGRAL test data and to validate FDS5 model

  16. Integral data test of HENDL1.0/MG and visualBUS with neutronics shielding experiments. Pt.1

    International Nuclear Information System (INIS)

    Gao Chunjing; Deng Tieru; Xu Dezheng; Li Jingjing; Wu Yican

    2004-01-01

    HENDL1.0/MG, a multi-group working library of the Hybrid Evaluated Nuclear Data Library, was home-developed by the FDS Team of ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences) on the basis of several national data libraries. To validate and qualify the process of producing HENDL1.0/MG, simulating calculations of a series of existent spherical shell benchmark experiments (Al, Mo, Co, Ti, Mn, W, Be and V) have been performed with HENDL1.0/MG and the multifunctional neutronics code system named VisualBUS home-developed also by FDS Team. (authors)

  17. Neutronics safety analysis in severe transients of the dual-cooled waste transmutation blanket for the FDS-I

    International Nuclear Information System (INIS)

    Zheng, S.; Wu, Y.

    2006-01-01

    The conceptual design of the fusion-driven subcritical system FDS-I with the multifunctional subcritical dual-cooled waste transmutation (DWT) blanket proposed as a middle step toward the final application of fusion energy was presented previously. Safety is a key concern for the innovative conceptual system. The potential safety characteristic is expected as one of the advantages of FDS-I for the transmutation and incineration of nuclear waste compared with the critical reactor. With the intent of evaluating the inherent and passive safety features of FDS-I, the reactivity coefficients (e.g. the coolant density/void effect and the Doppler feedback), which are similar to those in critical reactors, and the kinetics quantities (e.g. neutron generation time and β eff ), which are influenced by the external neutron source of the source-driven system, are calculated and analyzed. In addition, the specific transient scenarios for FDS-I, which show the effects of the source power perturbation on the safety parameters, is presented

  18. International Space Station Environmental Control and Life Support System Acceptance Testing for Node 1 Temperature and Humidity Control Subsystem

    Science.gov (United States)

    Williams, David E.

    2011-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.

  19. Activation analysis and waste management for dual-cooled lithium lead breeder (DLL) blanket of the fusion power reactor FDS-II

    International Nuclear Information System (INIS)

    Chen Mingliang; Huang Qunying; Li Jingjing; Zeng Qin; Wu Yican

    2005-01-01

    The calculation and analysis on the activation levels of the different regions of dual-cooled lithium-lead (DLL) breeder blanket of FDS-II, including afterheat, dose rate, activity and biological hazard potential after shutdown, were carried out with the neutronics code system VisualBUS and multi-group working library HENDL1.0/MG. The safety and environment assessment of fusion power (SEAFP) strategy for the management of activated material is here applied to the DLL blanket, to define the suitable recycling (reuse of activated material) procedure and the possibility of clearance (declassification of the material with low activity level to non-active waste). (authors)

  20. Recent developments for fast reactor structural design standard (FDS)

    International Nuclear Information System (INIS)

    Kasahara, N.; Nakamuria, K.; Morishita, M.; Shibamoto, H.; Nagashima, H.; Inoue, K.

    2005-01-01

    For realization of reliable and economical fast reactor (FR) plants, Japan Nuclear Cycle Development Institute(JNC) and Japan Atomic Power Company(JAPC) are cooperating on 'Feasibility Study on Commercialized FR Cycle Systems'. To certify the design concepts through evaluation of their structural integrity, the research and development of 'Elevated Temperature Structural Design Guide for Commercialized Fast Reactor (FDS)' is recognized as an essential theme. FDS focuses on particular failure modes of FRs such as ratchet deformation and creep fatigue damages due to cyclic thermal loads. To evaluate these modes, three main developments are in progress. One is 'Refinement of Failure Criteria' for particular modes of FRs. Next is development of 'Guidelines for Inelastic Design Analysis' in order to predict elastic plastic and creep behaviors. Furthermore, efforts are being made toward preparing 'Guidelines for Thermal Load Modeling' for FR component design where thermal loads are dominant. These studies were performed under the sponsorship of the Ministry of Economy, Trade and Industry of Japanese government. (authors)

  1. Software design specification and analysis(NuFDS) approach for the safety critical software based on porgrammable logic controller(PLC)

    International Nuclear Information System (INIS)

    Koo, Seo Ryong; Seong, Poong Hyun; Jung, Jin Yong; Choi, Seong Soo

    2004-01-01

    This paper introduces the software design specification and analysis technique for the safety-critical system based on Programmable Logic Controller (PLC). During software development phases, the design phase should perform an important role to connect between requirements phase and implementation phase as a process of translating problem requirements into software structures. In this work, the Nuclear FBD-style Design Specification and analysis (NuFDS) approach was proposed. The NuFDS approach for nuclear Instrumentation and Control (I and C) software are suggested in a straight forward manner. It consists of four major specifications as follows; Database, Software Architecture, System Behavior, and PLC Hardware Configuration. Additionally, correctness, completeness, consistency, and traceability check techniques are also suggested for the formal design analysis in NuFDS approach. In addition, for the tool supporting, we are developing NuSDS tool based on the NuFDS approach which is a tool, especially for the software design specification in nuclear fields

  2. [Screening for major dissociative disorders with the FDS, the German version of the Dissociative Experience Scale].

    Science.gov (United States)

    Rodewald, Frauke; Gast, Ursula; Emrich, Hinderk M

    2006-06-01

    The prevalence of major dissociative disorders (dissociative identity disorder, DID and similar forms of dissociative disorder not otherwise specified, DDNOS) in clinical samples is about 5 %. Despite their frequency, major dissociative disorders are often overseen for a long time. Screening-scales have proved to be effective to support clinical diagnosis. The aim of this study was to test, whether the Fragebogen für dissoziative Symptome (FDS), the German version of the Dissociative Experiences Scale (DES), differentiates between patients with dissociative disorders, non-dissociative disorders and non-clinical controls. Additionally, an optimal FDS-cutoff for a more detailed differential-diagnostic evaluation of the dissociative symptomatology should be identified. 150 participants with DID (group DID: n = 44), DDNOS (DDNOS: n = 22), posttraumatic disorders (TRAUMA: n = 20), other non-dissociative disorders (non-TRAUMA: n = 34) and non-clinical controls (KG: n = 30) completed the FDS. In the five diagnostic groups, mean values were calculated and compared for the FDS, DES and FDS-20. Via receiver-operating-curves the cutoff-scores, which differentiated best between participants with and without major dissociative disorders, were identified. FDS, DES and FDS-20 differentiate significantly between patients with and without major dissociative disorders. For all scales, there were significant differences between the diagnostic groups, with mean-scores decreasing continuously from the groups DID to DDNOS and TRAUMA. Between the groups non-TRAUMA and KG tendencies were found in the predicted direction. The optimal cutoff-scores to differentiate between participants with and without major dissociative disorders were 13 (FDS/FDS-20) and 15 (DES). Using these cutoff-scores, at least 90 % of the patients with major dissociative disorders could be identified correctly (sensitivity). The specifity of the scales was 0.89 to 0.90. Screening for major dissociative disorders

  3. International Space Station Environmental Control and Life Support System Acceptance Testing for Node 1 Atmosphere Control and Supply Subsystem

    Science.gov (United States)

    Williams, David E.

    2009-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the Node 1 ECLS ACS subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for that subsystem.

  4. FDS3 simulations of indoor hydrocarbon fires engulfing radioactive waste packages

    International Nuclear Information System (INIS)

    Bruecher, W.; Roewekamp, M.; Kunze, V.

    2004-01-01

    The thermal environment of a hypothetical large indoor hydrocarbon pool fire is more complex compared to outdoor fires and can be more severe for engulfed objects. In order to analyze potential thermal environments for interim storage of spent fuel casks or low-level radioactive waste packages engulfed in pool fires numerical simulations with the CFD fire code FDS3 were carried out for different storage configurations. In addition, data of indoor pool fire experiments were used to validate the model for this type of application. A series of pool fire experiments under different ventilation conditions and varied pool surface (1 m 2 - 4 m 2 ) inside a compartment of 3.6 m x 3.6 m x 5.7 m was conducted at iBMB (Institut fuer Baustoffe, Massivbau und Brandschutz) of Braunschweig University of Technology, Germany. The instrumentation included thermocouples, heatflux and pressure gauges, bi-directional flow probes and gas concentration measurements. A mock low-level waste drum equipped with outside and inside thermocouples was positioned as an additional heat sink near the fire source. Two of these experiments have recently been used for benchmarking a number of fire simulation codes within the International Collaborative Fire Model Project (ICFMP). FDS3 simulations by GRS of some of the above mentioned experiments will be presented showing the ability of the model to sufficiently well represent the fire environment in most cases. Further simulations were performed for hypothetical pool fire environments in interim storage facilities for German spent fuel transport and storage casks. The resulting temperature curves were then used for the thermomechanical analysis of the cask reaction performed by BAM (Bundesanstalt fuer Materialforschung und -pruefung, see corresponding conference paper by Wieser et al.). The FDS3 pool fire simulations show that the fire environment is strongly influenced by the ventilation conditions and cooling effects depending on the number and

  5. Economic analysis of the fusion-driven subcritical system

    International Nuclear Information System (INIS)

    Huang Desuo; Wu Yican; Chu Delin; Hu Liqin

    2004-01-01

    The economic performance of the Fusion-Driven Subcritical system (FDS) is discussed. At first, as an example, the impacts of parameters, such as plasma aspect-ratio, elongation, normalized beta, on-axis toroidal field and the blanket energy-gain are analyzed on the costs of the typical case (moderate aspect-ratio) of FDS. Then, the economic characteristics of the 3 possible scenarios of FDS are estimated with respect to the neutronics parameters. The results calculated with the SYSCODE developed by the FDS team show that the cost of electricity of Scenario-1 (low aspect-ratio) and Scenario-2 (moderate aspect-ratio) of FDS is cheaper than that of pure fusion power plant at the same plane size (1 GW e ). The cost of electricity of the FDS power plant depends heavily on the functions of blanket and the blanket energy-gain. (authors)

  6. Introduction of fusion driven subcritical system plasma design

    International Nuclear Information System (INIS)

    Bin Wu

    2003-01-01

    Fusion driven subcritical nuclear system (FDS) is a multifunctional hybrid reactor, which could breed nuclear fuel, transmute long-lived wastes, producing tritium and so on. This paper presents an introduction of FDS plasma design. Several different advance equilibrium configurations have been proposed and a 1.5-D discharge simulation of FDS was also present

  7. Investigating the burning characteristics of electric cables used in the nuclear power plant by way of 3-D transient FDS code

    Energy Technology Data Exchange (ETDEWEB)

    Ferng, Y.M., E-mail: ymferng@ess.nthu.edu.t [Department of Engineering and System Science, Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2. Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, C.H. [Department of Engineering and System Science, Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2. Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-01-15

    Burning characteristics of electrical cables are one of the key parameters for the fire hazard assessment of nuclear power plants (NPPs) since the cables are the essential sources of fire in the plants. A three-dimensional (3-D) transient computational fluid dynamics (CFD) code{sub F}DS is adopted in this paper to simulate these characteristics related to the cable burning. Being one of the NRC licensing fire codes, the FDS includes the thermal-hydraulic equations, the turbulence model and the chemical combustion model, etc. In order to assess the CFD fire models used in this code, a burning test using the control cable with the outer jacket of polyvinylchloride (PVC) and the inner insulation of cross-linked polyethylene (XLPE) is conducted. The measured parameters associated with the burning characteristics include the heat release rate (HRR), O{sub 2} depletion, and CO and CO{sub 2} production, etc. Except the amount of O{sub 2} consumption, the predicted transient behaviors of other parameters can reproduce the measured data. Based on the chemical combustion model in the FDS code, this discrepancy may be essentially resulted from the default value of hydrogen fraction (H{sub frac}) contained in the soot since the soot yield for the burning of PVC material is high enough that the uncertainty in the H{sub frac} value has a prominent effect on the amount of O{sub 2} consumption. This explanation can be confirmed by a benchmark calculation for simulating a burning test with the polymethylmethacrylate (PMMA) fuel of low-soot yield. The present simulation works can provide the useful information for the plant staff or the researcher as they would perform the fire hazard analysis in the NPPs using the FDS code.

  8. Prototyping of CBRN threat assessment system. Phase 1

    International Nuclear Information System (INIS)

    Ina, Shinichiro; Suzuki, Tomoyuki; Maeno, Akihiro; Sakaue, Motoki

    2015-01-01

    Recently, chemical, biological, radiological and nuclear threats, that is, CBRN threats have emerged. In order to support the Japan Self Defense Forces unit coping with the CBRN threats, it is important to take measures against these invisible threats. Our CBRN threat assessment system will make invisible CBRN threats visible. This report describes a prototyping of the CBRN threat assessment system (PHASE 1) carried out from fiscal year 2012-2014. (author)

  9. 291-B-1 stack monitoring and sampling system annual system assessment report

    International Nuclear Information System (INIS)

    Ridge, T.M.

    1994-01-01

    The B Plant 291-B-1 main stack exhausts gaseous effluents to the atmosphere from the 221-B Building canyon and cells, the No. 1 Vessel Ventilation System (VVS1), the 212-B Cask Station cell ventilation system, and, to a limited capacity, the 224-B Building. VVS1 collects offgases from various process tanks in 221-B Building, while the 224-B system maintains a negative pressure in out-of-service, sealed process tanks. B Plant Administration Manual, WHC-CM-7-5, Section 5.30 requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with Stack 291-B-1 (System Number B977A) at B Plant. The system is functional and performing satisfactorily

  10. Activation analysis of tritium breeder lithium lead irradiated by fusion neutrons in FDS-II

    International Nuclear Information System (INIS)

    Mingliang Chen

    2006-01-01

    R-and-D of fusion materials, especially their activation characteristics, is one of the key issues for fusion research in the world. Research on activation characteristics for low activation materials, such as reduced activation ferritic/martensitic steels, vanadium alloys and SiCf/SiC composites, is being done throughout the world to ensure the attractiveness of fusion power regarding safety and environmental aspects. However, there is less research on the activation characteristics of the other important fusion materials, such as tritium breeder etc.. Lithium lead (Li 17 Pb 83 ) is presently considered as a primary candidate tritium breeder for fusion power reactors because of its attractive characteristics. It can serve as a tritium breeder, neutron multiplier and coolant in the blanket at the same time. The radioactivity of Li 17 Pb 83 by D-T fusion neutrons in FDS-II has been calculated and analyzed. FDS-II is a concept design of fusion power reactor, which consists of fusion core with advanced plasma parameters extrapolated from the ITER (International Thermonuclear Experimental Reactor) and two candidates of liquid lithium breeder blankets (named SLL and DLL blankets). The neutron transport and activation calculation are carried out based on the one-dimensional model for FDS-II with the home-developed multi-functional code system VisualBUS and the multi-group data library HENDL1.0/MG and European Activation File EAF-99. The effects of irradiation time on the activation characteristics of Li 17 Pb 83 were analyzed and it concludes that the irradiation time has an important effect on the activation level of Li 17 Pb 83 . Furthermore, the results were compared with the activation levels of other tritium breeders, such as Li 4 SiO 4 , Li 2 TiO 3 , Li 2 O and Li etc., under the same irradiation conditions. The dominant nuclides to dose rate and activity of Li 17 Pb 83 were analyzed as well. Tritium generated by Li has a great contribution to the afterheat and

  11. Engineering Assessment and Certification of Integrity of the 490-Q1 tank system

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, W.W. [Lawrence Livermore National Lab., CA (United States); Gee, C.W.; Graser, D.A. [Science Applications International Corp., San Diego, CA (US)

    1993-07-01

    This Engineering Assessment and Certification of Integrity of used freon storage tanks 490-Q1A1 and 490-Q1A2 has been prepared in response to 40 CFR 265.192(a) and 22 CCR 66265.192(a) for new tank systems that store hazardous waste and have secondary containment. The regulations require that this assessment be completed and certified by an independent, qualified, California-registered professional engineer before the tank system is placed in use as a hazardous waste storage tank system. The technical assessments for the 490-Q1A1 and 490-Q1A2 tank systems have been reviewed by an independent, qualified, California-registered professional engineer, who has certified that the tank systems have sufficient structural integrity, are acceptable for transferring and storing hazardous waste, are compatible with the stored waste, and the tanks and containment system are suitably designed to achieve the requirements of the applicable regulations so they will not collapse, rupture, or fail.

  12. International Space Station Temperature and Humidity Control Subsystem Verification for Node 1

    Science.gov (United States)

    Williams, David E.

    2007-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the nominal operation of the Node 1 THC subsystem design. The paper will also provide a discussion of the detailed Element Verification methodologies for nominal operation of the Node 1 THC subsystem operations utilized during the Qualification phase.

  13. Methodology for assessing the safety of Hydrogen Systems: HyRAM 1.1 technical reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Groth, Katrina; Hecht, Ethan; Reynolds, John Thomas; Blaylock, Myra L.; Erin E. Carrier

    2017-03-01

    The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM is envisioned as a unifying platform combining validated, analytical models of hydrogen behavior, a stan- dardized, transparent QRA approach, and engineering models and generic data for hydrogen installations. HyRAM is being developed at Sandia National Laboratories for the U. S. De- partment of Energy to increase access to technical data about hydrogen safety and to enable the use of that data to support development and revision of national and international codes and standards. This document provides a description of the methodology and models contained in the HyRAM version 1.1. HyRAM 1.1 includes generic probabilities for hydrogen equipment fail- ures, probabilistic models for the impact of heat flux on humans and structures, and computa- tionally and experimentally validated analytical and first order models of hydrogen release and flame physics. HyRAM 1.1 integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hydrogen hazards (thermal effects from jet fires, overpressure effects from deflagrations), and assessing impact on people and structures. HyRAM is a prototype software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals.

  14. Sensitivity analysis of FDS 6 results for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Alvear, Daniel; Puente, Eduardo; Abreu, Orlando [Cantabria Univ., Santander (Spain). Group GIDAI - Fire Safety-Research and Technology; Peco, Julian [Consejo de Seguridad Nuclear, Madrid (Spain)

    2015-12-15

    The Spanish standard ''Instruction IS-30, Rev. 1'' (February 21, 2013) allows the new approaches of risk informed performance based design (PBD) The Spanish standard ''Instruction IS-30, rev. 1'' (February 21, 2013) for demonstrating the safe shutdown capability in case of fire in nuclear power plants. In this sense, fire computer models have become an interesting tool to study real fire scenarios. Such models use a set of input parameters that define the features of the physical domain, material, radiation, turbulence, etc. This paper analyses the impact of the grid size and different sub-models of the fire simulation code FDS, version 6 with the objective to evaluate and define their relative weight in the final simulation results. For the grid size analysis, two different scale scenarios were selected, the bench scale test PENLIGHT and a large-scale test similar to Appendix B of NUREG - 1934 (17 m x 10 m x 4.6 m, with an ignition source of 2 MW and 16 cable trays). For the sub-model analysis, the PRS-INT4 real scale configuration of the INTEGRAL experimental campaign of the international OECD PRISME Project has been used. The results offer relevant data for users and show the critical parameters that must be selected properly to guarantee the quality of the simulations.

  15. International Space Station Atmosphere Control and Supply, Atmosphere Revitalization, and Water Recovery and Management Subsystem - Verification for Node 1

    Science.gov (United States)

    Williams, David E.

    2007-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the nominal operation of the Node 1 ACS, AR, and WRM design and detailed Element Verification methodologies utilized during the Qualification phase for Node 1.

  16. Psacoin level 1A intercomparison probabilistic system assessment code (PSAC) user group

    International Nuclear Information System (INIS)

    Nies, A.; Laurens, J.M.; Galson, D.A.; Webster, S.

    1990-01-01

    This report describes an international code intercomparison exercise conducted by the NEA Probabilistic System Assessment Code (PSAC) User Group. The PSACOIN Level 1A exercise is the third of a series designed to contribute to the verification of probabilistic codes that may be used in assessing the safety of radioactive waste disposal systems or concepts. Level 1A is based on a more realistic system model than that used in the two previous exercises, and involves deep geological disposal concepts with a relatively complex structure of the repository vault. The report compares results and draws conclusions with regard to the use of different modelling approaches and the possible importance to safety of various processes within and around a deep geological repository. In particular, the relative significance of model uncertainty and data variability is discussed

  17. TRAC-PF1 code assessment using OECD LOFT LP-FP-1 experiment

    International Nuclear Information System (INIS)

    Barbero, F.J.

    1992-04-01

    This report assesses thermal-hydraulic aspects of LOFT LP-FP-1 experiment making use of TRAC-PF1/MOD1. LP-FP-1 experiment studies the system thermal-hydraulic and core thermal response for initial and boundary conditions similar to a large-break design basis LOCA leading to fission product release from the fuel cladding gap region. It also assesses the fission product retention effectiveness of the PWR-ECCS in best estimate conditions

  18. Evaluation of the influence of a postulated lubrication oil fire on safety related cables in the top shield platform of PFBR RCB by using FDS Code

    International Nuclear Information System (INIS)

    Mangarjuna Rao, P.; Jayasuriya, C.; Nashine, B.K.; Chellapandi, P.; Velusamy, K.

    2010-01-01

    Top deck of Prototype Fast Breeder Reactor (PFBR) primary system houses redundant safety related systems like Control and Safety Rod Drive Mechanisms (CSRDM), Diverse Safety Rod Drive Mechanism (DSRDM), subassembly outlet sodium temperature measurement system and central canal plug. These systems protrude out from the reactor through the Control Plug (CP), which is supported on the Top Shield (TS) of PFBR. Control and instrumentation signal cables and power cables of these safety related systems that are coming out from the CP are routed through Top Shield Platform (TSP, which is concentric with Reactor Vault (RV) at EL 34.1 m above the TS) to the peripheral local instrumentation control centers via the cable junction boxes supported on TS. Influence approach fire hazard analysis (FHA) has been carried out to evaluate the condition of redundant safety related cables under the scenario of a postulated oil fire in the TSP using Fire Dynamics Simulator code (FDS, Version 5). FDS is a computational fluid dynamics (CFD) based fire analysis code and it is developed by National Institute of Standards and Technology (NIST), USA. In this paper the details of the model developed and the results of the analysis carried out are discussed. In TSP, a postulated oil fire scenario with complete inventory of a primary sodium pump (PSP) lubrication oil leak (200 lt) has been considered at 30 m elevation on the TS. Computational model with the geometry of TSP and with other important structural components on TS like PSPs, intermediate heat exchangers (IHXs), large rotating plug (LRP), small rotating plug (SRP), CP and etc. has been developed along with a fire of 1800 kW/m 2 heat release rate in the vicinity of the PSP1. Numerical simulation has been carried out to evaluate this oil fire influence on the typical safety related cables routed at 34 m elevation. It has been found that the surface temperature of the cables that are routed directly above the fire only crosses the ignition

  19. Sleep disorders in Charcot-Marie-Tooth disease type 1.

    Science.gov (United States)

    Boentert, Matthias; Knop, Katharina; Schuhmacher, Christine; Gess, Burkhard; Okegwo, Angelika; Young, Peter

    2014-03-01

    Obstructive sleep apnoea (OSA) and restless legs syndrome (RLS) have been reported in Charcot-Marie-Tooth disease (CMT) type 1A and axonal subtypes of CMT, respectively. The aim of this case-control study was to investigate both prevalence and severity of OSA, RLS and periodic limb movements in sleep (PLMS) in adult patients with genetically proven CMT1. 61 patients with CMT1 and 61 insomnic control subjects were matched for age, sex, and Body Mass Index. Neurological disability in patients with CMT was assessed using the Functional Disability Scale (FDS). RLS diagnosis was based on a screening questionnaire and structured clinical interviews. All participants underwent overnight polysomnography. OSA was present in 37.7% of patients with CMT1 and 4.9% of controls (psleep quality. In addition to known risk factors, CMT may predispose to OSA. RLS is highly prevalent not only in axonal subtypes of CMT but also in primarily demyelinating subforms of CMT. PLMS are common in CMT1, but do not significantly impair sleep quality.

  20. FDS simulation of the fuel fireball from a hypothetical commercial airliner crash on a generic nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Luther, Wolfgang [GRS, Forschungsinstitute, Garching (Germany); Mueller, W. Christoph [GRS, Forschungsinstitute, Garching (Germany)], E-mail: mur@grs.de

    2009-10-15

    In the aftermath of 9/11 events it became clear that the impact of a fast flying commercial airliner hitting the NPP could no longer be excluded as a potential external hazard threatening the nuclear power plant (NPP) safety. One of the potential consequences of the impact is the occurrence of a fireball, large enough to engulf the entire NPP. The knowledge about fireballs from air crashes is rather poor since it is only based on footage shot by chance. From careful physical and chemical examinations using first principles, it can be concluded that the physics and chemistry of the kerosene fireball are similar to BLEVE fireballs in gas tank accidents which have been studied during the last decades. The knowledge from these analyses can be applied to air crash fireball analysis. In order to obtain an adequate understanding of the potential hazards to a NPP engulfed by a fireball a detailed analysis of the fireball is necessary. It is only by a detailed analysis that the effect of the NPP structures on the evolution of the fireball can be derived. Though the safety-relevant parts of the NPP are strong concrete structures, according to IAEA regulations the hypothesized entry of combustion products into ventilation or air supply systems and the entry of fuel into buildings through normal openings have to be analyzed in detail. This requires local transient values of the safety-relevant fireball parameters. With the NPP being a very large structure an adequately detailed simulation requires large computing grids and substantial computing power. With the release of Version 5 of the Fire Dynamic Simulator (FDS) from NIST in 2007 a simulation tool is now available which is capable to perform simulations of large fireballs on sufficiently large computing grids. These fireball simulations can be performed also by any other CFD code in which the relevant models have been implemented. The FDS fireball simulation capabilities were validated with the help of a well

  1. Design and Testing of the Fusion Virtual Assembly System FVAS1.0

    International Nuclear Information System (INIS)

    Pengcheng Long; Songlin Liu; Yican Wu

    2006-01-01

    Virtual assembly (VA), utilizing virtual reality (VR) technologies to plan and evaluate assembly process, retains the benefits (time-saving, inexpensive and no hazardous) of VR technologies and conquers the shortcoming of physical prototypes, such as long circle, high cost, low precision, and so on. Presented in this paper is the Fusion Virtual Assembly System FVAS 1.0 that makes possible engineering application for assemblies of large-scale complex nuclear facilities. FVAS 1.0 is designed to support the planning, evaluation and demonstration of assembly process, and training assemblers, and to work on PC (personal computer) platform. In this paper, architecture and main features of FVAS are introduced firstly. Then, design of the key sections (such as collision detection, virtual roaming) are described in detail. Finally, some successful application cases are presented. To enhance the real-time performance for large-scale nuclear facilities simulation, a policy based on separation of display scene and collision detection scene has been adopted. The display scene can be predigested to reduce the time of scene refreshment, and the collision detection performance is greatly improved by using the mature interference check ability of commercial CAD systems. Convenient observation mechanism brings more practicability. So a multi-viewpoints roaming scheme has been utilized to facilitate users' assembly operation. Users can obtain much optical information from multiple angles by switching between multi-viewpoints. The ESAT superconducting tokamak is characterized by large volume, complicated constitution and high assembly precision, e.g. the strict precision requirement in the assembly for the three tori (the tori of vacuum vessel, thermal shield, and toroidal coil). FVAS 1.0 has succeeded in demonstrating the assembly process of ESAT components. Furthermore, FVAS 1.0 has been applied to evaluate FDS-I (Fusion-Driven Sub-critical system) concept from assembly point of

  2. Nuclear plant service water system aging degradation assessment: Phase 1

    International Nuclear Information System (INIS)

    Jarrell, D.B.; Johnson, A.B. Jr.; Zimmerman, P.W.; Gore, M.L.

    1989-06-01

    The initial phase of an aging assessment of nuclear power plant service water systems (SWSs) was performed by the Pacific Northwest Laboratory to support the Nuclear Regulatory Commission Nuclear Plant Aging Research (NPAR) program. The SWS was selected for study because of its essential role in the mitigation of and recovery from accident scenarios involving the potential for core-melt. The objectives of the SWS task under the NPAR program are to identify and characterize the principal aging degradation mechanisms relevant to this system and assess their impact on operational readiness, and to provide a methodology for the mitigation of aging on the service water aspect of nuclear plant safety. The first two of these objectives have been met and are covered in this Phase 1 report. A review of available literature and data-base information indicated that motor operated valve torque switches (an electro-mechanical device) were the prime suspect in component service water systems failures. More extensive and detailed data obtained from cooperating utility maintenance records and personnel accounts contradicted this conclusion indicating that biologic and inorganic accumulation and corrosive attack of service water on component surfaces were, in fact, the primary degradation mechanisms. A review of the development of time dependent risk assessment (aging) models shows that, as yet, this methodology has not been developed to a degree where implementation is reliable. Improvements in the accuracy of failure data documentation and time dependent risk analysis methodology should yield significant gains in relating aging phenomena to probabilistic risk assessment. 23 refs., 8 figs., 10 tabs

  3. On non-linear dynamics of coupled 1+1DOF versus 1+1/2DOF Electro-Mechanical System

    DEFF Research Database (Denmark)

    Darula, Radoslav; Sorokin, Sergey

    2014-01-01

    The electro-mechanical systems (EMS) are used from nano-/micro-scale (NEMS/MEMS) up to macro-scale applications. From mathematical view point, they are modelled with the second order differential equation (or a set of equations) for mechanical system, which is nonlinearly coupled with the second...... or the first order differential equation (or a set of equations) for electrical system, depending on properties of the electrical circuit. For the sake of brevity, we assume a 1DOF mechanical system, coupled to 1 or 1/2DOF electrical system (depending whether the capacitance is, or is not considered......). In the paper, authors perform a parametric study to identify operation regimes, where the capacitance term contributes to the non-linear behaviour of the coupled system. To accomplish this task, the classical method of multiple scales is used. The parametric study allows us to assess for which applications...

  4. Project SAFE. Update of the SFR-1 safety assessment. Phase 1

    International Nuclear Information System (INIS)

    Andersson, Johan; Riggare, P.; Skagius, K.

    1998-10-01

    SFR-1 is a facility for disposal of low-level radioactive operational waste from the nuclear power plants in Sweden. Low-level radioactive waste from industry, medicine, and research is also disposed in SFR-1. The facility is situated in bedrock beneath the Baltic Sea, 1 km off the coast near the Forsmark nuclear power plant. SFR-1 was built between the years 1983 and 1988. An assessment of the long-term performance of the facility was included in the vast documentation that was a part of the application for an operational license. The assessment was presented in the form of a final safety report. In the operational licence for SFR-1 it is stated that renewed safety assessments should be carried out at least each ten years. In order to meet this demand SKB has launched a special project, SAFE (Safety Assessment of Final Disposal of Operational Radioactive Waste). The aim of the project is to update the safety analysis and to prepare a safety report that will be presented to the Swedish authorities not later than year 2000. Project SAFE is divided into three phases. The first phase is a prestudy, and the results of the prestudy are given in this report. The aim of the prestudy is to identify issues where additional studies would improve the basis for the updated safety analysis as well as to suggest how these studies should be carried out. The work has been divided into six different topics, namely the inventory, the near field, the far field, the biosphere, radionuclide transport calculations and scenarios. For each topic the former safety reports and regulatory reviews are scrutinised and needs for additional work is identified. The evaluations are given in appendices covering the respective topics. The main report is a summary of the appendices with a more stringent description of the repository system and the processes that are of interest and therefore should be addressed in an updated safety assessment. However, it should be pointed out that one of the

  5. FDS Modeling of the Sensitivity of the Smoke Potential Values used in Fire Safety Strategies

    DEFF Research Database (Denmark)

    Corches, Andrei-Mircea; Ulriksen, Lene; Jomaas, Grunde

    2014-01-01

    To investigate the sensitivity of Fire Dynamics Simulator (FDS) with respect to the input parameters that are used to define the optical properties of the smoke, a parametric study was performed for relevant fire scenarios in an open plan office building. The parametric study mainly focuses on th...... to defining the design fires will reduce the sensitivity of the numerical fire simulation and further reduce the risk of overestimating the evacuation safety level (ESL) of the building....

  6. Hepatic Steatosis in Morbidly Obese Patients Undergoing Gastric Bypass Surgery: Assessment With Open-System 1H-MR Spectroscopy

    NARCIS (Netherlands)

    van Werven, Jochem R.; Schreuder, Tim C. M. A.; Aarts, Edo O.; Nederveen, Aart J.; Meijer, Jos W. R.; Berends, Frits J.; Janssen, Ignace M. C.; Mulder, Chris J.; Jansen, Peter L. M.; Stoker, Jaap

    2011-01-01

    The purpose of this study was to assess, with histopathologic control, the use of open-system 1-T (1)H MR spectroscopy for the evaluation of hepatic steatosis in morbidly obese patients undergoing gastric bypass surgery. Patients underwent (1)H MR spectroscopy (MRS) for the assessment of steatosis

  7. Viability Assessment Volume 1

    International Nuclear Information System (INIS)

    1998-01-01

    Since May 1996, under its draft Civilian Radioactive Waste Management Program Plan (DOE 1996), DOE has been carrying out a 5-year program of work to support the decision in 2001 by the Secretary of Energy on whether or not to recommend the site to the President. Part of this program was to address major unresolved technical issues and to complete an assessment of the viability of the Yucca Mountain site by 1998. Affirming the DOE plans, Congress directed DOE in the 1997 Energy and Water Development Appropriations Act to provide a viability assessment of the Yucca Mountain site to Congress and the President. This Viability Assessment (VA) document is the DOE report to Congress and the President. They are expected to use the VA to make an informed decision about program direction and funding. Drawing on 15 years of scientific investigation and design work at Yucca Mountain, the VA summarizes a large technical basis of field investigations, laboratory tests, models, analyses, and engineering, described in cited references. The VA identifies the major uncertainties relevant to the technical defensibility of DOE analyses and designs, the DOE approach to managing these uncertainties, and the status of work toward the site recommendation and LA. The VA also identifies DOE plans for the remaining work, and the estimated costs of completing an LA and constructing and operating a repository. The attention to uncertainties is important because DOE must evaluate how the repository will perform during the next 10,000 years or longer. Uncertainties exist because of variability in the natural (geologic and hydrologic) systems at Yucca Mountain and because of imperfect scientific understanding of the natural processes that might affect the repository system. This is Volume 1 and it covers, Introduction and Site Characteristics, includes a high-level summary of the results of the VA and some additional background information. (The overview is bound separately.) Section 1 of Volume

  8. Preliminary analysis of advanced equilibrium configuration for the fusion-driven subcritical system

    International Nuclear Information System (INIS)

    Chu Delin; Wu Bin; Wu Yican

    2003-01-01

    The Fusion-Driven Subcritical System (FDS) is a subcritical nuclear energy system driven by fusion neutron source. In this paper, an advanced plasma configuration for FDS system has been proposed, which aims at high beta, high bootstrap current and good confinement. A fixed-boundary equilibrium code has been used to obtain ideal equilibrium configuration. In order to determine the feasibility of FDS operation, a two-dimensional time-dependent free boundary simulation code has been adopted to simulate time-scale evolution of plasma current profile and boundary position. By analyses, the Reversed Shear mode as the most attractive one has been recommended for the FDS equilibrium configuration design

  9. HIFSA: Heavy-Ion Fusion Systems Assessment Project: Volume 1, Executive summary

    International Nuclear Information System (INIS)

    Dudziak, D.J.; Herrmannsfeldt, W.B.; Saylor, W.W.

    1987-12-01

    The Heavy-Ion Fusion Systems Assessment (HIFSA) was conducted with the specific objective of evaluating the prospects of using induction-linac heavy-ion accelerators to generate economical electrical power from Inertial Confinement Fusion (ICF). Cost/performance models of the major fusion power plant systems were used to identify promising areas in parameter space. Resulting cost-of-electricity projections for a plant size of 1 GWe are comparable to those from other fusion system studies, some of which were for much larger power plants. These favorable projections maintain over an unusually large domain of parameter space but depend especially on making large cost savings for the accelerator by using higher charge-to-mass ratio ions than assumed previously. The feasibility of realizing such savings has been shown by (1) experiments demonstrating transport stability better than anticipated for space-charge-dominated beams, and (2) theoretical predictions that the final transport and pulse compression in reactor-chamber environments will be sufficiently resistant to streaming instabilities to allow successful propagation of neutralized beams to the target. Results of the HIFSA study already have had a significant impact on the heavy-ion induction accelerator R and D program, especially in selection of the charge-state objectives. Also, the study should enhance the credibility of induction linacs as ICF drivers

  10. FdC1 and Leaf-Type Ferredoxins Channel Electrons From Photosystem I to Different Downstream Electron Acceptors.

    Science.gov (United States)

    Guan, Xiaoqian; Chen, Shuai; Voon, Chia Pao; Wong, Kam-Bo; Tikkanen, Mikko; Lim, Boon L

    2018-01-01

    Plant-type ferredoxins in Arabidopsis transfer electrons from the photosystem I to multiple redox-driven enzymes involved in the assimilation of carbon, nitrogen, and sulfur. Leaf-type ferredoxins also modulate the switch between the linear and cyclic electron routes of the photosystems. Recently, two novel ferredoxin homologs with extra C-termini were identified in the Arabidopsis genome (AtFdC1, AT4G14890; AtFdC2, AT1G32550). FdC1 was considered as an alternative electron acceptor of PSI under extreme ferredoxin-deficient conditions. Here, we showed that FdC1 could interact with some, but not all, electron acceptors of leaf-type Fds, including the ferredoxin-thioredoxin reductase (FTR), sulfite reductase (SiR), and nitrite reductase (NiR). Photoreduction assay on cytochrome c and enzyme assays confirmed its capability to receive electrons from PSI and donate electrons to the Fd-dependent SiR and NiR but not to the ferredoxin-NADP + oxidoreductase (FNR). Hence, FdC1 and leaf-type Fds may play differential roles by channeling electrons from photosystem I to different downstream electron acceptors in photosynthetic tissues. In addition, the median redox potential of FdC1 may allow it to receive electrons from FNR in non-photosynthetic plastids.

  11. Independent Orbiter Assessment (IOA): Assessment of the orbiter main propulsion system FMEA/CIL, volume 1

    Science.gov (United States)

    Slaughter, B. C.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. The Orbiter MPS is composed of the Propellant Management Subsystem (PMS) consisting of the liquid oxygen (LO2) and liquid hydrogen (LH2) subsystems and the helium subsystem. The PMS is a system of manifolds, distribution lines, and valves by which the liquid propellants pass from the External Tank to the Space Shuttle Main Engine (SSME). The helium subsystem consists of a series of helium supply tanks and their associated regulators, control valves, and distribution lines. Volume 1 contains the MPS description, assessment results, ground rules and assumptions, and some of the IOA worksheets.

  12. Robust fault detection of wind energy conversion systems based on dynamic neural networks.

    Science.gov (United States)

    Talebi, Nasser; Sadrnia, Mohammad Ali; Darabi, Ahmad

    2014-01-01

    Occurrence of faults in wind energy conversion systems (WECSs) is inevitable. In order to detect the occurred faults at the appropriate time, avoid heavy economic losses, ensure safe system operation, prevent damage to adjacent relevant systems, and facilitate timely repair of failed components; a fault detection system (FDS) is required. Recurrent neural networks (RNNs) have gained a noticeable position in FDSs and they have been widely used for modeling of complex dynamical systems. One method for designing an FDS is to prepare a dynamic neural model emulating the normal system behavior. By comparing the outputs of the real system and neural model, incidence of the faults can be identified. In this paper, by utilizing a comprehensive dynamic model which contains both mechanical and electrical components of the WECS, an FDS is suggested using dynamic RNNs. The presented FDS detects faults of the generator's angular velocity sensor, pitch angle sensors, and pitch actuators. Robustness of the FDS is achieved by employing an adaptive threshold. Simulation results show that the proposed scheme is capable to detect the faults shortly and it has very low false and missed alarms rate.

  13. Safety assessment for the proposed pilot-scale treatability tests for the 200-UP-1 and 200-ZP-1 groundwater operable units. Revision 1

    International Nuclear Information System (INIS)

    1994-12-01

    This safety assessment provides an analysis of the proposed pilot-scale treatability test activities to be and conducted within the 200 Area groundwater operable units on the Hanford Site. The 200-UP-1 and 200-ZP-1 operable units are located in the 200 West Area of the Hanford Site. These tests will evaluate an ion exchange (IX) water purification treatment system and granular activated carbon (GAC). A detailed engineering analysis of (GAC) adsorption for remediation of groundwater contamination. A detailed engineering analysis of the IX treatment system. The principal source of information for this assessment, states that the performance objective of the treatment systems is to remove 90% of the uranium and technetium-99 ( 99 Tc) from the extracted groundwater at the 200-UP-1 site. The performance objective for 200-ZP-1 is to remove 90% of the carbon tetrachloride (CCl 4 ), chloroform, and trichloroethylene (TCE) from the extracted groundwater

  14. Divertor modelling for conceptual studies of tokamak fusion reactor FDS-III

    International Nuclear Information System (INIS)

    Chen Yiping; Liu Songlin

    2010-01-01

    Divertor modelling for the conceptual studies of tokamak fusion reactor FDS-III was carried out by using the edge plasma code package B2.5-Eirene (SOLPS5.0). The modelling was performed by taking real MHD equilibrium and divertor geometry of the reactor into account. The profiles of plasma temperature, density and heat fluxes in the computational region and at the target plates have been obtained. The modelling results show that, with the fusion power P fu =2.6 GW and the edge density N edge =6.0x10 19 l/m 3 , the peak values of electron and ion heat fluxes at the outer target plate of divertor are respectively 93.92 MW/m 2 and 58.50 MW/m 2 . According to the modelling results it is suggested that some methods for reducing the heat fluxes at the target plates should be used in order to get acceptable level of power flux at the target plates for the divertor design of the reactor.

  15. A methodology for the quantitative evaluation of NPP fault diagnostic systems' dynamic aspects

    International Nuclear Information System (INIS)

    Kim, J.H.; Seong, P.H.

    2000-01-01

    A fault diagnostic system (FDS) is an operator decision support system which is implemented both to increase NPP efficiency as well as to reduce human error and cognitive workload that may cause nuclear power plant (NPP) accidents. Evaluation is an indispensable activity in constructing a reliable FDS. We first define the dynamic aspects of fault diagnostic systems (FDSs) for evaluation in this work. The dynamic aspect is concerned with the way a FDS responds to input. Next, we present a hierarchical structure in the evaluation for the dynamic aspects of FDSs. Dynamic aspects include both what a FDS provides and how a FDS operates. We define the former as content and the latter as behavior. Content and behavior contain two elements and six elements in the lower hierarchies, respectively. Content is a criterion for evaluating the integrity of a FDS, the problem types which a FDS deals with, along with the level of information. Behavior contains robustness, understandability, timeliness, transparency, effectiveness, and communicativeness of FDSs. On the other hand, the static aspects are concerned with the hardware and the software of the system. For quantitative evaluation, the method used to gain and aggregate the priorities of the criteria in this work is the analytic hierarchy process (AHP). The criteria at the lowest level are quantified through simple numerical expressions and questionnaires developed in this work. these well describe the characteristics of the criteria and appropriately use subjective, empirical, and technical methods. Finally, in order to demonstrate the feasibility of our evaluation method, we have performed one case study for the fault diagnosis module of OASYS TM (On-Line Operator Aid SYStem for Nuclear Power Plant), which is an operator support system developed at the Korea Advanced Institute of Science and Technology (KAIST)

  16. IDC System Specification Document Version 1.1.

    Energy Technology Data Exchange (ETDEWEB)

    Harris, James M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lober, Randall R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    This document contains the system specifications derived to satisfy the system requirements found in the IDC System Requirements Document for the IDC Reengineering Phase 2 project. Revisions Version Date Author/Team Revision Description Authorized by V1.0 12/2014 IDC Reengineering Project Team Initial delivery M. Harris V1.1 2/2015 IDC Reengineering Project Team Iteration I2 Review Comments M. Harris

  17. Waste receiving and processing (WRAP) module 1 hazards assessment. Revision 1

    International Nuclear Information System (INIS)

    Sutton, L.N.

    1997-01-01

    This report documents the hazards assessment for the Waste Receiving and Processing Module I (WRAP 1) located on the U.S. Department of Energy (DOE) Hanford Site. Operation of the WRAP 1 is the responsibility of Rust Federal Services Hanford (RFSH). This hazards assessment was conducted to provide the emergency planning technical basis for the WRAP 1. DOE Orders require an emergency planning hazards assessment for each facility that has the potential to reach or exceed the lowest level emergency classification

  18. Development on hybrid evaluated nuclear data library HENDL1.0/MG/MC

    International Nuclear Information System (INIS)

    Xu Dezheng; Gao Chunjing; Zheng Shanliang; Liu Haibo; Zhu Xiaoxiang; Li Jingjing; Wu Yican

    2004-01-01

    A Hybrid Evaluated Nuclear Data Library (HENDL) named as HENDL1.0 has been developed by Fusion Design Study (FDS) team of Institute of Plasma Physics, Academia Sinica (ASIPP) to take into account the requirements in design and research relevant to fusion, fission and fusion-fission sub-critical hybrid reactor. HENDLI1.0 contains one basic evaluated sub-library naming HENDL1.0/E and to processed working sub-libraries naming HENDL1.0/MG and HENDL1.0/MC, respectively. Through carefully comparing, distinguishing and choosing, HENDL1.0/E integrated basic evaluated neutron data files of 213 nuclides from the several main data libraries for evaluated neutron reaction cross sections including ENDF/B-VI (USA), JEF-2.2 (OECD/NEA, Europe), JENDL-3.2 (Japan), CENDL-2 (China), BROND-2 (Russia) and FENDL-2 (IAEA/NDS, ITER program). Based on this, 175-group neutron and 42-group photon neutron-photon coupled multi-group working library HENDL1.0/MG used for discrete ordinate Sn method transport calculation (such as ANISN code) and a compact ENDF form (ACE), continuous energy structure (pointwise) neutron cross section library HENDL1.0/MC for Monte Carlo method transport simulation (as MCMP code) can be attainable with the current group constants processing system NJOY and transport cross section preparation code TRANSX referring to the Vitamin-J energy group structure. In addition, two special bases i.e. transmutation (burnup) library BURNUP. DAT and response function library RESPONSE.DAT, have been also made for fuel cycle calculation and reactivity analyses of nuclear reactor. The relevant sample testing, benchmark checking and primary confirmation are also carried out to assess the validity of multi-purpose data library HENDL1.0. (authors)

  19. Production and testing of HENDL-2.1/CG coarse-group cross-section library based on ENDF/B-VII.0

    International Nuclear Information System (INIS)

    Xu Dezheng; He Zhaozhong; Zou Jun; Zeng Qin

    2010-01-01

    A coarse-group coupled neutron and photon (27n + 21γ) cross-section library HENDL-2.1/CG, based on ENDF/B-VII.0 evaluate data source, has been produced by FDS Team in Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). HENDL-2.1/CG containing 350 nuclide cross-section files (from 1 H to 252 Cf) was generated in MATXS format with the NJOY processing system and then by compiling coarse-group problem-dependent format using the TRANSX code. In order to verify the availability and reliability of the HENDL-2.1/CG data library, requisite benchmark calculations were performed and compared with HENDL-2.0/MG fine-group coupled neutron and photon (175n + 42γ) cross-section library. In general, results using the coarse-group library showed similarly believable as fine-group library.

  20. Automotive Manufacturing Assessment System : Volume 1. Master Product Schedules.

    Science.gov (United States)

    1999-11-01

    Volume I is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of in...

  1. Experimental study and thermodynamic assessment of the ZrO2-DyO1.5 system

    International Nuclear Information System (INIS)

    Wang, Chong; Zinkevich, M.; Aldinger, F.; Stuttgart Univ.

    2007-01-01

    The phase equilibria and thermodynamic properties in the ZrO 2 -DyO 1.5 system have been studied using the experimental methods of X-ray diffraction, scanning electron microscopy, energy dispersive X-ray spectroscopy, differential thermal analysis and high temperature drop calorimetry. The tetragonal + fluorite and fluorite + C-Dy 2 O 3 phase equilibria between 1400 C and 1700 C have been determined, together with the enthalpy increments of the materials with 30 mol.% and 50 mol.% DyO 1.5 in the temperature range 200-1400 C. Furthermore, the martensitic transformation temperatures (A s ,M s ) have been measured for the samples with 1 and 2 mol.% DyO 1.5 . Finally, thermodynamic assessment has been carried out using the experimental results obtained and literature data. (orig.)

  2. Tritium supply assessment for ITER and DEMOnstration power plant

    International Nuclear Information System (INIS)

    Ni, Muyi; Wang, Yongliang; Yuan, Baoxin; Jiang, Jieqiong; Wu, Yican

    2013-01-01

    Highlights: • The tritium production rate in CANDU reactor was simulated and estimated. • Possible routes, including APT, CLWR and tritium production schemes of ADS, were evaluated in feasibility and economy. • The possible tritium consumption of ITER and initial supply for DEMO was assessed. • Result of supply and demand showed that after ITER retired in 2038, the tritium production in CANDU reactor might not be enough for a FDS-II scale DEMO reactor startup if without additional tritium resource. -- Abstract: The International Thermonuclear Experimental Reactor (ITER) and next generation DEMOnstration fusion reactor need amounts of tritium for test/initial startup and will consume kilograms tritium for operation per year. The available supply of tritium for fusion reactor is man-made sources. Now most of commercial tritium resource is extracted from moderator and coolant of CANada Deuterium Uranium (CANDU) type Heavy Water Reactor (HWR), in the Ontario Hydro Darlington facility of Canada and Wolsong facility of Korea. In this study, the tritium production rate in CANDU reactor was simulated and estimated. And other possible routes, including Accelerator Production of Tritium (APT), tritium production in Commercial Light Water Reactor (CLWR) and Accelerator Driven Subcritical system (ADS), were also evaluated in feasibility and economy. Based on the tritium requirement investigated according to ITER test schedule and startup inventory required for a FDS-II-scale DEMO calculated by TAS1.0, the assessment results showed that after ITER retired in 2038, the tritium inventory of CANDU reactor could not afford DEMO reactor startup without extra resource

  3. Tritium supply assessment for ITER and DEMOnstration power plant

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Muyi, E-mail: muyi.ni@fds.org.cn; Wang, Yongliang; Yuan, Baoxin; Jiang, Jieqiong; Wu, Yican

    2013-10-15

    Highlights: • The tritium production rate in CANDU reactor was simulated and estimated. • Possible routes, including APT, CLWR and tritium production schemes of ADS, were evaluated in feasibility and economy. • The possible tritium consumption of ITER and initial supply for DEMO was assessed. • Result of supply and demand showed that after ITER retired in 2038, the tritium production in CANDU reactor might not be enough for a FDS-II scale DEMO reactor startup if without additional tritium resource. -- Abstract: The International Thermonuclear Experimental Reactor (ITER) and next generation DEMOnstration fusion reactor need amounts of tritium for test/initial startup and will consume kilograms tritium for operation per year. The available supply of tritium for fusion reactor is man-made sources. Now most of commercial tritium resource is extracted from moderator and coolant of CANada Deuterium Uranium (CANDU) type Heavy Water Reactor (HWR), in the Ontario Hydro Darlington facility of Canada and Wolsong facility of Korea. In this study, the tritium production rate in CANDU reactor was simulated and estimated. And other possible routes, including Accelerator Production of Tritium (APT), tritium production in Commercial Light Water Reactor (CLWR) and Accelerator Driven Subcritical system (ADS), were also evaluated in feasibility and economy. Based on the tritium requirement investigated according to ITER test schedule and startup inventory required for a FDS-II-scale DEMO calculated by TAS1.0, the assessment results showed that after ITER retired in 2038, the tritium inventory of CANDU reactor could not afford DEMO reactor startup without extra resource.

  4. Computer-aided assessment of pulmonary disease in novel swine-origin H1N1 influenza on CT

    Science.gov (United States)

    Yao, Jianhua; Dwyer, Andrew J.; Summers, Ronald M.; Mollura, Daniel J.

    2011-03-01

    The 2009 pandemic is a global outbreak of novel H1N1 influenza. Radiologic images can be used to assess the presence and severity of pulmonary infection. We develop a computer-aided assessment system to analyze the CT images from Swine-Origin Influenza A virus (S-OIV) novel H1N1 cases. The technique is based on the analysis of lung texture patterns and classification using a support vector machine (SVM). Pixel-wise tissue classification is computed from the SVM value. The method was validated on four H1N1 cases and ten normal cases. We demonstrated that the technique can detect regions of pulmonary abnormality in novel H1N1 patients and differentiate these regions from visually normal lung (area under the ROC curve is 0.993). This technique can also be applied to differentiate regions infected by different pulmonary diseases.

  5. Assessment of ICARE/CATHARE V1 Severe Accident Code

    International Nuclear Information System (INIS)

    Chatelard, Patrick; Fleurot, Joelle; Marchand, Olivier; Drai, Patrick

    2006-01-01

    The ICARE/CATHARE code system has been developed by the French 'Institut de Radioprotection et de Surete Nucleaire' (IRSN) in the last decade for the detailed evaluation of Severe Accident (SA) consequences in a primary system. It is composed of the coupling of the core degradation IRSN code ICARE2 and of the thermal-hydraulics French code CATHARE2. It has been extensively used to support the level 2 Probabilistic Safety Assessment (PSA-2) of the 900 MWe PWR. This paper presents the synthesis of the ICARE/CATHARE V1 assessment which was conducted in the frame of the 'International ICARE/CATHARE Users' Club', under the management of IRSN. The ICARE/CATHARE V1 validation matrix is composed of more than 60 experiments, distributed in few thermal-hydraulics non-regression tests (to handle the front end phase of a severe accident), numerous Separate-Effect Tests, about 30 Integral Tests covering both the early and the late degradation phases, as well as a 'circuit' experiment including hydraulics loops. Finally, the simulation of the TMI-2 accident was also added to assess the code against real conditions. This validation task was aimed at assessing the ICARE/CATHARE V1 capabilities (including the stand-alone ICARE2 V3mod1 version) and also at proposing recommendations for an optimal use of this version ('Users' Guidelines'). Thus, with a correct account for the recommended guidelines, it appeared that the last ICARE/CATHARE V1 version could be reasonably used to perform best-estimate reactor studies up to a large corium slumping into the lower head. (authors)

  6. Assessment of TRAC-BD1/MOD1 using FIST data

    International Nuclear Information System (INIS)

    Jo, J.H.; Connell, H.R.

    1985-01-01

    This report is concerned with the assessment of the TRAC-BD1/MOD1 Code, developed at Idaho National Engineering Laboratory. The assessment was conducted using data from the FIST (Full Integral Simulation Test) facility, which is a BWR safety test facility which was built to investigate small break LOCA and operational transients in BWR's and to complement earlier large break LOCA test results from TLTA (Two-Loop Test Apparatus). 21 figs

  7. Uncertainty and sensitivity analysis using probabilistic system assessment code. 1

    International Nuclear Information System (INIS)

    Honma, Toshimitsu; Sasahara, Takashi.

    1993-10-01

    This report presents the results obtained when applying the probabilistic system assessment code under development to the PSACOIN Level 0 intercomparison exercise organized by the Probabilistic System Assessment Code User Group in the Nuclear Energy Agency (NEA) of OECD. This exercise is one of a series designed to compare and verify probabilistic codes in the performance assessment of geological radioactive waste disposal facilities. The computations were performed using the Monte Carlo sampling code PREP and post-processor code USAMO. The submodels in the waste disposal system were described and coded with the specification of the exercise. Besides the results required for the exercise, further additional uncertainty and sensitivity analyses were performed and the details of these are also included. (author)

  8. Mission hazard assessment for STARS Mission 1 (M1) in the Marshall Islands area

    Energy Technology Data Exchange (ETDEWEB)

    Outka, D.E.; LaFarge, R.A.

    1993-07-01

    A mission hazard assessment has been performed for the Strategic Target System Mission 1 (known as STARS M1) for hazards due to potential debris impact in the Marshall Islands area. The work was performed at Sandia National Laboratories as a result of discussion with Kwajalein Missile Range (KMR) safety officers. The STARS M1 rocket will be launched from the Kauai Test Facility (KTF), Hawaii, and deliver two payloads to within the viewing range of sensors located on the Kwajalein Atoll. The purpose of this work has been to estimate upper bounds for expected casualty rates and impact probability or the Marshall Islands areas which adjoin the STARS M1 instantaneous impact point (IIP) trace. This report documents the methodology and results of the analysis.

  9. SGA Phase 1 Assessed Reaches

    Data.gov (United States)

    Vermont Center for Geographic Information — The stream geomorphic assessment (SGA) is a physical assessment competed by geomorphologists to determine the condition and sensitivity of a stream. The Phase 1 SGA...

  10. DESIGN PACKAGE 1E SYSTEM SAFETY ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    M. Salem

    1995-06-23

    The purpose of this analysis is to systematically identify and evaluate hazards related to the Yucca Mountain Project Exploratory Studies Facility (ESF) Design Package 1E, Surface Facilities, (for a list of design items included in the package 1E system safety analysis see section 3). This process is an integral part of the systems engineering process; whereby safety is considered during planning, design, testing, and construction. A largely qualitative approach was used since a radiological System Safety Analysis is not required. The risk assessment in this analysis characterizes the accident scenarios associated with the Design Package 1E structures/systems/components(S/S/Cs) in terms of relative risk and includes recommendations for mitigating all identified risks. The priority for recommending and implementing mitigation control features is: (1) Incorporate measures to reduce risks and hazards into the structure/system/component design, (2) add safety devices and capabilities to the designs that reduce risk, (3) provide devices that detect and warn personnel of hazardous conditions, and (4) develop procedures and conduct training to increase worker awareness of potential hazards, on methods to reduce exposure to hazards, and on the actions required to avoid accidents or correct hazardous conditions.

  11. (1)H MRS assessment of hepatic steatosis in overweight children and adolescents

    DEFF Research Database (Denmark)

    Chabanova, Elizaveta; Bille, Dorthe S; Thisted, Ebbe

    2012-01-01

    magnetic resonance systems due to limited space. The purpose of this study was to examine the ability of open 1T system to monitor liver fat with proton MRS and to compare hepatic fat fractions (HFFs) obtained using an open 1T system with assessment with 3T proton MRS. METHODS: The study included 23...

  12. National Ignition Facility sub-system design requirements computer system SSDR 1.5.1

    International Nuclear Information System (INIS)

    Spann, J.; VanArsdall, P.; Bliss, E.

    1996-01-01

    This System Design Requirement document establishes the performance, design, development and test requirements for the Computer System, WBS 1.5.1 which is part of the NIF Integrated Computer Control System (ICCS). This document responds directly to the requirements detailed in ICCS (WBS 1.5) which is the document directly above

  13. Assessment of ALWR passive safety system reliability. Phase 1: Methodology development and component failure quantification

    International Nuclear Information System (INIS)

    Hake, T.M.; Heger, A.S.

    1995-04-01

    Many advanced light water reactor (ALWR) concepts proposed for the next generation of nuclear power plants rely on passive systems to perform safety functions, rather than active systems as in current reactor designs. These passive systems depend to a great extent on physical processes such as natural circulation for their driving force, and not on active components, such as pumps. An NRC-sponsored study was begun at Sandia National Laboratories to develop and implement a methodology for evaluating ALWR passive system reliability in the context of probabilistic risk assessment (PRA). This report documents the first of three phases of this study, including methodology development, system-level qualitative analysis, and sequence-level component failure quantification. The methodology developed addresses both the component (e.g. valve) failure aspect of passive system failure, and uncertainties in system success criteria arising from uncertainties in the system's underlying physical processes. Traditional PRA methods, such as fault and event tree modeling, are applied to the component failure aspect. Thermal-hydraulic calculations are incorporated into a formal expert judgment process to address uncertainties in selected natural processes and success criteria. The first phase of the program has emphasized the component failure element of passive system reliability, rather than the natural process uncertainties. Although cursory evaluation of the natural processes has been performed as part of Phase 1, detailed assessment of these processes will take place during Phases 2 and 3 of the program

  14. Assessment of TRAC-PF1/MOD1 code for large break LOCA in PWR

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Ohnuki, Akira; Murao, Yoshio; Abe, Yutaka.

    1993-03-01

    As the first step of the REFLA/TRAC code development, the TRAC/PF1/MOD1 code has been assessed for various experiments that simulate postulated large-break loss-of-coolant accident (LBLOCA) in PWR to understand the predictive capability and to identify the problem areas of the code. The assessment calculations were performed for separate effect tests for critical flow, counter current flow, condensation at cold leg and reflood as well as integral tests to understand predictability for individual phenomena. This report summarizes results from the assessment calculations of the TRAC-PF1/MOD1 code for LBLOCA in PWR. The assessment calculations made clear the predictive capability and problem areas of the TRAC-PF1/MOD1 code for LBLOCA in PWR. The areas, listed below, should be improved for more realistic and effective simulation of LBLOCA in PWR: (1) core heat transfer model during blowdown, (2) ECC bypass model at downcomer during refill, (3) condensation model during accumulator injection, and (4) core thermal hydraulic model during reflood. (author) 57 refs

  15. Life Cycle Assessment (LCA for Wheat (Triticum aestivum L. Production Systems of Iran: 1- Comparison of Inputs Level

    Directory of Open Access Journals (Sweden)

    Mahdi Nassiri Mahallati

    2018-02-01

    Full Text Available Introduction Agricultural intensification has serious environmental consequences such as depletion of non-renewable resources, emission of greenhouse gases, threatening of biodiversity and pollution of both surface and underground water resources. The life cycle assessment (LCA provides a standard method for assessing environmental impacts from various economic activities, including agriculture, and covers a wide range of impact categories across the entire production chain. Over the past few decades, food production in Iran has been increased drastically due to heavier use of chemical inputs. Since the use of LCA method is overlooked for assesseing the effects of agricultural intensification in Iran and few researches are conducted at local level (such as province, cities, the purpose of this research is evaluation of wheat production systems throughout the country based on the level of intensification using LCA method. Materials and Methods Fourteen provinces covering 80 percent of total cultivated area of wheat production in the country were subjected to a cradle to gate LCA study using the standard method. The selected provinces were classified as low, medium and high input based on the level of intensification and all inputs and emissions were estimated within the system boundaries during inventory stage. Required data for yield, and level of applied inputs for 14 provinces were collected from the official databases of the Ministry of Jihad Agriculture. The various environmental impacts including, abiotic resource depletion, land use, global warming potential, acidification and eutrophication potential, human, aquatic and terrestrial ecotoxicity potential of wheat production systems over the country was studied based on emission coefficients and characterization factors provided by standard literatures. The integrated effects of emission of each impact category were calculated per functional units (hectare cultivated area as well as ton

  16. Variation in FCN1 affects biosynthesis of ficolin-1 and is associated with outcome of systemic inflammation

    DEFF Research Database (Denmark)

    Munthe-fog, L; Hummelshoj, T; Honoré, C

    2012-01-01

    ), -271 (rs28909976), -144 (rs10117466) and +7918 (rs1071583) were determined in 100 healthy individuals. FCN1 expression by isolated monocytes and granulocytes and ficolin-1 levels in monocyte culture supernatants were assessed in 21 FCN1-genotyped individuals. FCN1 polymorphisms were determined...... in a cohort of 251 patients with systemic inflammation. High ficolin-1 plasma levels were significantly associated with the minor alleles in position -542 and -144. These alleles were also significantly associated with high FCN1 mRNA expression. The level of ficolin-1 in culture supernatants was significantly...

  17. Toxicity assessment of modified Cry1Ac1 proteins and genetically ...

    African Journals Online (AJOL)

    Owner

    2015-06-10

    Jun 10, 2015 ... Key words: Modified Cry1Ac1, food safety assessment, toxicity, insect- resistant rice Agb0101. INTRODUCTION. Genetically modified (GM) crops are becoming an increasingly important feature of the agricultural land- scapes. In 2013, approximately 175 million hectares of. GM crops were planted by 18 ...

  18. Development of System Model for Level 1 Probabilistic Safety Assessment of TRIGA PUSPATI Reactor

    International Nuclear Information System (INIS)

    Tom, P.P; Mazleha Maskin; Ahmad Hassan Sallehudin Mohd Sarif; Faizal Mohamed; Mohd Fazli Zakaria; Shaharum Ramli; Muhamad Puad Abu

    2014-01-01

    Nuclear safety is a very big issue in the world. As a consequence of the accident at Fukushima, Japan, most of the reactors in the world have been reviewed their safety of the reactors including also research reactors. To develop Level 1 Probabilistic Safety Assessment (PSA) of TRIGA PUSPATI Reactor (RTP), three organizations are involved; Nuclear Malaysia, AELB and UKM. PSA methodology is a logical, deductive technique which specifies an undesired top event and uses fault trees and event trees to model the various parallel and sequential combinations of failures that might lead to an undesired event. Fault Trees (FT) methodology is use in developing of system models. At the lowest level, the Basic Events (BE) of the fault trees (components failure and human errors) are assigned probability distributions. In this study, Risk Spectrum software used to construct the fault trees and analyze the system models. The results of system models analysis such as core damage frequency (CDF), minimum cut set (MCS) and common cause failure (CCF) uses to support decision making for upgrading or modification of the RTP?s safety system. (author)

  19. TRAC-PF1/MOD1 independent assessment: Semiscale Mod-2A intermediate break test S-IB-3

    International Nuclear Information System (INIS)

    Kmetyk, L.N.

    1986-02-01

    The TRAC-PF1/MOD1 independent assessment project at Sandia National Laboratories is part of an overall effort funded by the NRC to determine the ability of various system codes to predict the detailed thermal/hydraulic response of light water reactors during accident and off-normal conditions. The TRAC code is being assessed at SNLA against test data from various integral and separate effects test facilities. As part of this assessment matrix, an intermediate break test (S-IB-3), performed at the Semiscale Mod-2A facility, has been analyzed. Using an input model with a 3-D VESSEL component, the vessel and downcomer inventories during 3-IB-3 were generally well predicted, but the core heatup was underpredicted compared to data. An equivalent calculation with an all 1-D input model ran about twice as fast as our basecase analysis using a 3-D VESSEL in the input model, but the results of the two calculations diverged significantly for many parameters of interest, with the 3-D VESSEL model results in better agreement with data. 22 refs., 100 figs

  20. Neutronic design and analysis on dual-cooled waste transmutation blanket for the fusion driven sub-critical system

    International Nuclear Information System (INIS)

    Zheng Shanliang; Wu Yican; Gao Chunjing; Xu Dezheng; Li Jingjing; Zhu Xiaoxiang

    2004-01-01

    Neutronics design and analysis of dual-cooled multi-functional waste transmutation blanket (DWTB) for the fusion driven sub-critical system (FDS) are performed to ensure the system be able to meet the requirements of fuel-sufficiency and more waste transmutation ratio with low initial loading fuel inventory, which is based on 1-D burn-up calculations with home-developed code Visual BUS and the multi-group (175 neutron groups-42 Gamma groups coupled) data library HENDL1.0/MG (Hybrid Evaluated Nuclear Data Library). (authors)

  1. Practical application of the KMS: 1) total system performance assessment - 16349

    International Nuclear Information System (INIS)

    Makino, Hitoshi; Hioki, Kazumasa; Umeki, Hiroyuki; Yang, Hongzhi; Takase, Hiroyasu; McKinley, Ian

    2009-01-01

    Comprehensive total system performance assessment (PA) is a key component of the safety case. Within this PA there are a number of tasks that reuse specific models and datasets, together with associated knowledge base for the disposal system considered. These are tasks where recent developments in the Knowledge Management System by Japan Atomic Energy Agency (JAEA KMS) can lead to optimisation of procedures. This paper will outline the reformulation of PA as a Knowledge Management (KM) task, discuss application of KM technologies to PA tasks, and illustrate how these can be handled electronically in a 'Performance assessment All-In-one Report System (PAIRS)' utilising hyper-links and embedded tools to minimise duplication of material, ease Quality Assurance (QA) and facilitate the regular updating required in the Japanese programme. (authors)

  2. Reliability assessment of PARR-1 renovated I and C system startup channel-b

    Energy Technology Data Exchange (ETDEWEB)

    Qamar, M.A.; Habib, M.A.; Iqbal, M.

    1991-11-20

    The report covers the reliability assessment of the startup channel-B of the PARR-1 renovated instrumentation and Control. For startup channel-A, a separate report (DNSRP-10(7)/88) was prepared in 1988. As the modules are of different origins in both the channels, a separate calculation was necessary. In the report the overall unreliability of the startup channel has been calculated by considering 1 out of 2 operation mode. In the assessment, the reliability calculations for the channel has been performed using similar assumptions as used in the authors' report on startup channel-A. For the analysis the Component Count Method (CCM) was applied. Comparison of results for channel-A and channel-B were made.

  3. Data processing system for TPE-1 to TPE-1RM15

    International Nuclear Information System (INIS)

    Yahagi, Eiichi

    1991-01-01

    This paper reports the research and development of the data acquisition and processing system for TPE-1 to TPE-1RM15. The program to develop the system was initiated for the TPE-1 project in 1971. The TPE-1 machine was afterward reconstructed into TPE-1R, TPE-1RM and TPE-1RM15 in order. During this course, some modifications and improvements on the system had been made. The system had worked well for fifteen years from the end of 1973 fiscal year to the end of 1988 fiscal year. In 1989 the system was replaced by the present system, which will be described in a separate report. TPE-1 is a high-beta toroidal screw pinch machine for the magnetic confinement nuclear fusion research at the Electrotechnical Laboratory (ETL). TPE-1R, TPE-1RM and TEP-1RM15, are reversed field pinch machines. In the design of the system, the particular attention was paid to several problems inherent to high-beta plasma diagnostics, such as responsibility up to 10MHz, sensitivity at a very low signal level and protection against intense electromagnetic noises. The mean time to perform a floating point instruction was several hundred microseconds. We had made various contrivances and efforts to perform required work within the required time under the situation of the small memory area and the low throughput of the computer system. In this paper, general lines of the system design and development, and the hardware and software of the system including the filing system are described in detail. Some schemes to give high-quality data for analytical processing stage by means of pattern recognition of data signals, smoothing and other techniques, as well as a basic structurization of procedural software to save resources and labors, are also described. (J.P.N.)

  4. Microelectronic systems 1 checkbook

    CERN Document Server

    Vears, R E

    2013-01-01

    Microelectronic Systems 1 Checkbook provides coverage of the Business and Technician Education Council level 1 unit in Microelectronic Systems. However, it can be regarded as a basic textbook in microelectronic systems for a much wider range of studies. Each topic considered in the text is presented in a way that assumes the reader has little prior knowledge of electronics. The aim of the book is to provide an introduction to the concept of systems, to differentiate analogue and digital systems, and to describe the nature of microprocessor-controlled systems. An introduction to programming is

  5. Heart rate variability (HRV) and muscular system activity (EMG) in cases of crash threat during simulated driving of a passenger car.

    Science.gov (United States)

    Zużewicz, Krystyna; Roman-Liu, Danuta; Konarska, Maria; Bartuzi, Paweł; Matusiak, Krzysztof; Korczak, Dariusz; Lozia, Zbigniew; Guzek, Marek

    2013-10-01

    The aim of the study was to verify whether simultaneous responses from the muscular and circulatory system occur in the driver's body under simulated conditions of a crash threat. The study was carried out in a passenger car driving simulator. The crash was included in the driving test scenario developed in an urban setting. In the group of 22 young male subjects, two physiological signals - ECG and EMG were continuously recorded. The length of the RR interval in the ECG signal was assessed. A HRV analysis was performed in the time and frequency domains for 1-minute record segments at rest (seated position), during undisturbed driving as well as during and several minutes after the crash. For the left and right side muscles: m. trapezius (TR) and m. flexor digitorum superficialis (FDS), the EMG signal amplitude was determined. The percentage of maximal voluntary contraction (MVC) was compared during driving and during the crash. As for the ECG signal, it was found that in most of the drivers changes occurred in the parameter values reflecting HRV in the time domain. Significant changes were noted in the mean length of RR intervals (mRR). As for the EMG signal, the changes in the amplitude concerned the signal recorded from the FDS muscle. The changes in ECG and EMG were simultaneous in half of the cases. Such parameters as mRR (ECG signal) and FDS-L amplitude (EMG signal) were the responses to accident risk. Under simulated conditions, responses from the circulatory and musculoskeletal systems are not always simultaneous. The results indicate that a more complete driver's response to a crash in road traffic is obtained based on parallel recording of two physiological signals (ECG and EMG).

  6. Management assessment of tank waste remediation system contractor readiness to proceed with phase 1B privatization

    International Nuclear Information System (INIS)

    Honeyman, J.O.

    1998-01-01

    This Management Assessment of Tank Waste Remediation System (TWRS) Contractor Readiness to Proceed With Phase 1B Privatization documents the processes used to determine readiness to proceed with tank waste treatment technologies from private industry, now known as TWRS privatization. An overall systems approach was applied to develop action plans to support the retrieval and disposal mission of the TWRS Project. The systems and infrastructure required to support the mission are known. Required systems are either in place or plans have been developed to ensure they exist when needed. Since October 1996 a robust system engineering approach to establishing integrated Technical Baselines, work breakdown structures, tank farms organizational structure and configurations, work scope, and costs has become part of the culture within the TWRS Project. An analysis of the programmatic, management, and technical activities necessary to declare readiness to proceed with execution of the mission demonstrates that the system, personnel, and hardware will be on-line and ready to support the private contractors. The systems approach included defining the retrieval and disposal mission requirements and evaluating the readiness of the Project Hanford Management Contract (PHMC) team to support initiation of waste processing by the private contractors in June 2002 and to receive immobilized waste shortly thereafter. The Phase 1 feed delivery requirements from the private contractor Requests for Proposal were reviewed. Transfer piping routes were mapped, existing systems were evaluated, and upgrade requirements were defined

  7. Preliminary conceptual design of target system. Pt. 1. System configuration

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Ryutaro; Haga, Katsuhiro; Kaminaga, Masanori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    1997-07-01

    In the 21st century, neutron is expected to play a very important role in the fields of structural biology, nuclear physics, material science if a very high-intensity neutron source will be built because of its superior nature as an probe to investigate material structure and its function. The Japan Atomic Energy Research Institute has launched the Neutron Science Project for construction and utilization of a high-intensity spallation neutron source coupled with a proton accelerator. In the project, a neutron scattering facility is planned to be constructed in an early stage. Development of a 5MW spallation neutron source is one of the most difficult technical challenges in this project. A two-step development plan of the target was established to construct a 5MW-target station In the 1st step, a 1.5MW target will be constructed to develop 5MW target technology. The preliminary conceptual design was conducted to clarify the specifications of the target system of 1.5MW and 5MW including system layout, scale etc. This report describes (1) a design policy, (2) a layout of system consisting of the target, remote-handling devices, bio-shieldings etc., (3) specifications of components and facilities such as cooling systems for target and moderators, beam-port shutter and air conditioning system, (4) overhaul procedures by remote-handling devices, (5) safety assessment, and (6) necessary R and D items derived from the design activity. (author)

  8. FDS5 Simulation for OECD PRISME Fire Test of DOOR PRSD5

    International Nuclear Information System (INIS)

    Lee, Kyu Bok; Park, Jong Seuk

    2009-01-01

    OECD/NEA PRISME Fire Project is an international co-operation project to investigate fire propagation by means of experiments and analyses for nuclear power plant applications. This project focuses on the generation of experimental data for fire and smoke propagation from the fire room to adjacent rooms under various conditions and room configurations. In addition, analyses using computer codes are performed to understand the phenomena of interest and to produce a consistent interpretation of the experimental results. The PRISME Project is composed of series of tests named as SOURCE, DOOR, LEAK and Global Tests. The SOURCE is composed of tests to characterize the fire source, and the DOOR is to study fire and smoke propagation through an open door, while the LEAK is to investigate hot gas leakages through other modes of openings such as holes, a slot, a duct, and a partially opened door. The Global test will be conducted as integral tests on the basis of the results of the previous separate effects tests. In this paper, simulations are performed with FDS5 computer code for the DOOR Test No.5 (PRS D 5) and the calculation results are compared with the corresponding experimental data to study the code capability to predict the phenomena of the hot gas propagation between two rooms

  9. Unitary relation for the time-dependent SU(1,1) systems

    International Nuclear Information System (INIS)

    Song, Dae-Yup

    2003-01-01

    The system whose Hamiltonian is a linear combination of the generators of SU(1,1) group with time-dependent coefficients is studied. It is shown that there is a unitary relation between the system and a system whose Hamiltonian is simply proportional to the generator of the compact subgroup of SU(1,1). The unitary relation is described by the classical solutions of a time-dependent (harmonic) oscillator. Making use of the relation, the wave functions satisfying the Schroedinger equation are given, for a general unitary representation, in terms of the matrix elements of a finite group transformation (Bargmann function). The wave functions of the harmonic oscillator with an inverse-square potential is studied in detail, and it is shown that through an integral, the model provides a way of deriving the Bargmann function for the representation of positive discrete series of SU(1,1)

  10. Assessing Argentina's response to H1N1 in austral winter 2009: from presidential lethargy to local ingenuity.

    Science.gov (United States)

    Stern, Alexandra Minna; Koreck, Maria Teresa; Markel, Howard

    2011-01-01

    Argentina experienced a heavy burden of novel H1N1 influenza in austral winter 2009. In early July 2009, Argentina reported more than 1,500 cases and was confronting the highest per capita H1N1 mortality rate in the world. By September 2009, more than 500 people had died of H1N1 in Argentina. Unlike sister countries Chile and Mexico, Argentina's national authorities did not respond by implementing mitigation measures such as public gathering bans and school closures or by issuing broad-based messages about personal hygiene and disease prevention. Around the globe, many observers expressed dismay at this inaction. For example, The Economist scolded the country's leadership for its halting response and seeming apathy to an escalating health crisis. Why did Argentina, a middle-income country with a developed and, in many respects, sophisticated system of health and education, fall short in enacting a national pandemic plan during the 2009 H1N1 outbreak? What can we learn from Argentina's experiences about obstacles and opportunities during a pandemic crisis? This article, based on extensive qualitative research, including document capture, media analysis, and oral history interviews, assesses Argentina's mixed response to H1N1 during austral winter 2009, and adds to a growing body of studies focused on how governments and health systems in the Americas performed during the 2009-2010 H1N1 pandemic. When the first cases of novel H1N1 influenza were identified by the U.S. Centers for Disease Control and Prevention (CDC) in mid-April 2009, Argentina's national health ministry appeared to be prepared. Starting in 2002, primarily in response to the prospect of avian influenza, the health ministry had formulated a preparedness plan and, beginning in 2005, had conducted at least five pandemic simulation exercises. In April 2009, Argentina's health ministry activated its pandemic response plan, triggering the establishment of an executive-level situation room equipped with

  11. Preliminary environmental assessment for the Satellite Power System (SPS). Revision 1. Volume 2. Detailed assessment

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    The Department of Energy (DOE) is considering several options for generating electrical power to meet future energy needs. The satellite power system (SPS), one of these options, would collect solar energy through a system of satellites in space and transfer this energy to earth. A reference system has been described that would convert the energy to microwaves and transmit the microwave energy via directive antennas to large receiving/rectifying antennas (rectennas) located on the earth. At the rectennas, the microwave energy would be converted into electricity. The potential environmental impacts of constructing and operating the satellite power system are being assessed as a part of the Department of Energy's SPS Concept Development and Evaluation Program. This report is Revision I of the Preliminary Environmental Assessment for the Satellite Power System published in October 1978. It refines and extends the 1978 assessment and provides a basis for a 1980 revision that will guide and support DOE recommendations regarding future SPS development. This is Volume 2 of two volumes. It contains the technical detail suitable for peer review and integrates information appearing in documents referenced herein. The key environmental issues associated with the SPS concern human health and safety, ecosystems, climate, and electromagnetic systems interactions. In order to address these issues in an organized manner, five tasks are reported: (I) microwave-radiation health and ecological effects; (II) nonmicrowave health and ecological effectss; (III) atmospheric effects; (IV) effects on communication systems due to ionospheric disturbance; and (V) electromagnetic compatibility. (WHK)

  12. Risk assessment of main control board fire using fire dynamics simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il, E-mail: dikang@kaeri.re.kr [KAERI, 1045 Daedeokdaero, Yuseong-Gu, Daejeon 305-353 (Korea, Republic of); Kim, Kilyoo; Jang, Seung-Cheol [KAERI, 1045 Daedeokdaero, Yuseong-Gu, Daejeon 305-353 (Korea, Republic of); Yoo, Seong Yeon [Chungnam National University, 79, Daehagro, Yuseong-Gu, Daejeon (Korea, Republic of)

    2015-08-15

    Highlights: • A decision tree for evaluating the risk of a main control board (MCB) fire was proposed to systematically determine the MCB fire scenarios. • Fire simulations using fire dynamics simulator (FDS) were performed to estimate the time to MCR abandonment. • Non-propagating and propagating fire scenarios were considered for fire simulations. • The current study indicates that the quantification of the MCB fire risk should address the propagating fire and non-propagating fire scenarios if the MCB has no internal barriers between the panels. - Abstract: This paper presents the process and results of a risk assessment for a main control board (MCB) fire using fire dynamics simulator (FDS). A decision tree for evaluating the risk of a MCB fire was proposed to systematically determine the MCB fire scenarios, and fire simulations using FDS were performed to estimate the time to MCR abandonment. As a reference NPP for this study, Hanul unit 3 in Korea was selected and its core damage frequency (CDF) owing to the MCB fire was quantified. Two types of fire scenarios were considered for fire simulations: non-propagating fire scenarios occurring within a single MCB panel and propagating fire scenarios spreading from one control panel to the adjacent panels. Further, the fire scenarios were classified into fires with and without a heating, ventilation, and air conditioning system (HVACS). The fire simulation results showed that the major factor causing the MCR evacuation was the optical density irrelevant to the availability of the HVACS. The risk assessment results showed that the abandonment fire scenario risk was less than the non-abandonment fire scenario risk and the propagating fire scenario risk was greater than the non-propagating fire scenario risk.

  13. Risk assessment of main control board fire using fire dynamics simulator

    International Nuclear Information System (INIS)

    Kang, Dae Il; Kim, Kilyoo; Jang, Seung-Cheol; Yoo, Seong Yeon

    2015-01-01

    Highlights: • A decision tree for evaluating the risk of a main control board (MCB) fire was proposed to systematically determine the MCB fire scenarios. • Fire simulations using fire dynamics simulator (FDS) were performed to estimate the time to MCR abandonment. • Non-propagating and propagating fire scenarios were considered for fire simulations. • The current study indicates that the quantification of the MCB fire risk should address the propagating fire and non-propagating fire scenarios if the MCB has no internal barriers between the panels. - Abstract: This paper presents the process and results of a risk assessment for a main control board (MCB) fire using fire dynamics simulator (FDS). A decision tree for evaluating the risk of a MCB fire was proposed to systematically determine the MCB fire scenarios, and fire simulations using FDS were performed to estimate the time to MCR abandonment. As a reference NPP for this study, Hanul unit 3 in Korea was selected and its core damage frequency (CDF) owing to the MCB fire was quantified. Two types of fire scenarios were considered for fire simulations: non-propagating fire scenarios occurring within a single MCB panel and propagating fire scenarios spreading from one control panel to the adjacent panels. Further, the fire scenarios were classified into fires with and without a heating, ventilation, and air conditioning system (HVACS). The fire simulation results showed that the major factor causing the MCR evacuation was the optical density irrelevant to the availability of the HVACS. The risk assessment results showed that the abandonment fire scenario risk was less than the non-abandonment fire scenario risk and the propagating fire scenario risk was greater than the non-propagating fire scenario risk

  14. Comparison and analysis of 1D/2D/3D neutronics modeling for a fusion reactor

    International Nuclear Information System (INIS)

    Li, J.; Zeng, Q.; Chen, M.; Jiang, J.; Wu, Y.

    2007-01-01

    During the course of analyzing the characteristics for fusion reactors, the refined calculations are needed to confirm that the nuclear design requirements are met. Since the long computational time is consumed, the refined three-dimensional (3D) representation has been used primarily for establishing the baseline reference values, analyzing problems which cannot be reduced by symmetry considerations to lower dimensions, or where a high level of accuracy is desired locally. The two-dimensional (2D) or one-dimensional (1D) description leads itself readily to resolve many problems, such as the studies for the material fraction optimization, or for the blanket size optimization. The purpose of this paper is to find out the differences among different geometric descriptions, which can guide the way to approximate and simplify the computational model. The fusion power reactor named FDS-II was designed as an advanced fusion power reactor to demonstrate and validate the commercialization of fusion power by Institute of Plasma Physics, Chinese Academy of Science. In this contribution, the dual-cooled lithium lead (DLL) blanket of FDS-II was used as a reference for neutronics comparisons and analyses. The geometric descriptions include 1D concentric sphere model, 1D, 2D and 3D cylinder models. The home-developed multi-functional neutronics analysis code system VisualBUS, the Monte Carlo transport code MCNP and nuclear data library HENDL have been used for these analyses. The neutron wall loading distribution, tritium breeding ratio (TBR) and nuclear heat were calculated to evaluate the nuclear performance. The 3D calculation has been used as a comparison reference because it has the least errors in the treatment of geometry. It is suggested that the value of TBR calculated by the 1D approach should be greater than 1.3 to satisfy the practical need of tritium self-sufficiency. The distribution of nuclear heat based on the 2D and 3D models were similar since they all consider

  15. Scientific investigation plan for NNWSI WBS element 1.2.2.5.L: NNWSI waste package performance assessment: Revision 1

    International Nuclear Information System (INIS)

    Eggert, K.G.; O'Connell, W.J.; Lappa, D.A.

    1986-01-01

    Waste package performance assessment contains three broad categories of activities. These activities are: (1) development of a hydrothermal flow and transport model to test concepts to be used in establishing boundary conditions for performance calculations, and to interface EBS release calculations with total system performance calculations; (2) development of a waste package systems model to provide integrated deterministic assessments of performance and analyses of waste package designs; and (3) development of an uncertainty methodology for combination with the system model to perform probabilistic reliability and performance analysis waste package designs. The first category contains activities that aid in determining the scope of a separate, simplified set of hydrologic calculations needed to characterize the waste package environment for performance assessment calculations. The last two activity categories are directly concerned with waste package performance calculations. A rationale for each activity under these groups is presented. All of the activities of performance assessment are either code development or analyses of waste package problems

  16. A Morphometric Study of the Foramen of Diaphragma Sellae and Delineation of Its Relation to Optic Neural Pathways through Computer Aided Superimposition

    Directory of Open Access Journals (Sweden)

    Doris George Yohannan

    2015-01-01

    Full Text Available The diaphragma sellae (DS is a fold of dura that forms a partial roof over the pituitary gland. The foramen of the diaphragma sellae (FDS is thereby a pathway for suprasellar extension of pituitary tumors. The purpose of this study was to describe the anatomical dimensions of the DS and FDS and to understand the relationship of FDS with the overlying optic chiasma. The study was conducted in 100 autopsy cases. Measurements were taken using vernier calipers. Photographs, taken before and after removal of optic pathway, were superimposed using image processing software. The results showed that the mean A-P dimension of DS was 1.17 ± 0.48 cm; the lateral dimension of DS was 1.58 ± 0.60 cm. The mean A-P dimension of FDS was 0.66 ± 0.42 cm; the lateral dimension of FDS was 0.82 cm ± 0.54 cm. The shapes of FDS were irregular (40%, transversely oval (29%, circular (13%, sagittally oval (11%, or trapezoid with posterior dimension more than the anterior one (6% or anterior dimension more than the posterior one (1%. The margins of FDS were either well defined (31% or ill defined (69%. The positional relation of FDS to optic chiasma was also found out.

  17. 26 CFR 1.6851-1 - Termination assessments of income tax.

    Science.gov (United States)

    2010-04-01

    ... TAX (CONTINUED) INCOME TAXES Additions to the Tax, Additional Amounts, and Assessable Penalties § 1... designs to do an act which would tend to prejudice proceedings to collect the income tax for such year or... compliance or to present any other evidence of compliance with income tax obligations. However, for the rules...

  18. Economic and Environmental Assessment of a 1 MW Grid Connected Rooftop Solar PV System for Energy Efficient Building in Bangladesh

    Science.gov (United States)

    Chakraborty, Sanjib; Hosain, Rubayet; Rahman, Toufiqur; Rabbi, Ahmead Fazle

    This paper evaluates the potentiality of a 1 MW grid connected rooftop solar PV system for an Energy Efficient Building in Bangladesh, which was estimated by utilizing NASA SSE solar radiation data, PVsyst simulation software and RETScreen simulation software. Economic and environmental viability for a ten-storied building with roof area of 6,500 m2 in the Capital City of Bangladesh, Dhaka was assessed by using the RETScreen simulation software. The yearly electricity production of the proposed system was 1,581 MWh estimated by PVsyst where the technical prospective of gird-connected solar PV in Bangladesh was calculated as about 50,174 MW. The economic assessments were determined the simple payback in such a way that the generated electricity first fulfills the demand of the building, and then the rest of the energy is supplied to the grid. The result indicates that the roof top solar PV system for an Energy efficient building in Dhaka city has a favorable condition for development both in economic and environmental point of view.

  19. Assessment of a gel-type chelating preparation containing 1-hydroxyethylidene-1, 1-bisphosphonate.

    Science.gov (United States)

    Girard, S; Paqué, F; Badertscher, M; Sener, B; Zehnder, M

    2005-11-01

    To test an aqueous gel containing 1-hydroxyethylidene-1, 1-bisphosphonate (HEBP) regarding its interactions with sodium hypochlorite, its calcium binding capacity, and its potential in preventing the formation of a smear layer when used in conjunction with rotary root canal preparation. The experimental aqueous gel consisted of (w/v) 2% alginate, 3% aerosil, 10% Tween 80 and 18% HEBP. Interactions of gel components with hypochlorite were assessed using iodometric titration and monochromatic ultraviolet spectrometry. Two commercial paste-type chelators containing ethylenediaminetetraacetic acid (EDTA) and peroxide (RC-Prep and Glyde) served as controls. Calcium-binding capacities were measured in mixtures with a Ca2+ standard solution buffered at pH 10 using a calcium-selective measuring chain. Finally, root canals of 16 extracted single-rooted premolars per group were instrumented using ProFile instruments dipped in the experimental gel, RC-Prep, or nothing. Additionally, canals were rinsed with 10 mL of a 1% NaOCl solution during/after preparation. Smear scores in instrumented teeth were monitored using scanning electron microscopy. None of the experimental gel components showed short-term interactions with hypochlorite, whilst EDTA, peroxide, RC-Prep and Glyde immediately reduced the hypochlorite in solution. The experimental gel chelated 30 mg Ca2+ g-1, compared with 16 mg Ca2+ g-1 and 11 mg Ca2+ g-1 chelated by RC-Prep and Glyde respectively. Smear scores obtained with the experimental gel were significantly (P<0.05) lower than with RC-Prep in coronal and middle root thirds, whilst no differences were observed in apical root thirds. Under the conditions of this study, an HEBP gel appeared advantageous over currently available products.

  20. Remedial action and waste disposal project -- 300-FF-1 remedial action readiness assessment report

    International Nuclear Information System (INIS)

    Carson, J.W.; Carlson, R.A.; Greif, A.A.; Johnson, C.R.; Orewiler, R.I.; Perry, D.M.; Remsen, W.E.; Tuttle, B.G.; Wilson, R.C.

    1997-09-01

    This report documents the readiness assessment for initial startup of the 300-FF-1 Remedial Action Task. A readiness assessment verifies and documents that field activities are ready to start (or restart) safely. The 300-FF-1 assessment was initiated in April 1997. Readiness assessment activities included confirming the completion of project-specific procedures and permits, training staff, obtaining support equipment, receipt and approval of subcontractor submittals, and mobilization and construction of site support systems. The scope of the 300-FF-1 Remedial Action Task includes excavation and disposal of contaminated soils at liquid waste disposal facilities and of waste in the 618-4 Burial Ground and the 300-FF-1 landfills. The scope also includes excavation of test pits and test trenches

  1. Hybrid flux splitting schemes for numerical resolution of two-phase flows

    Energy Technology Data Exchange (ETDEWEB)

    Flaatten, Tore

    2003-07-01

    This thesis deals with the construction of numerical schemes for approximating. solutions to a hyperbolic two-phase flow model. Numerical schemes for hyperbolic models are commonly divided in two main classes: Flux Vector Splitting (FVS) schemes which are based on scalar computations and Flux Difference Splitting (FDS) schemes which are based on matrix computations. FVS schemes are more efficient than FDS schemes, but FDS schemes are more accurate. The canonical FDS schemes are the approximate Riemann solvers which are based on a local decomposition of the system into its full wave structure. In this thesis the mathematical structure of the model is exploited to construct a class of hybrid FVS/FDS schemes, denoted as Mixture Flux (MF) schemes. This approach is based on a splitting of the system in two components associated with the pressure and volume fraction variables respectively, and builds upon hybrid FVS/FDS schemes previously developed for one-phase flow models. Through analysis and numerical experiments it is demonstrated that the MF approach provides several desirable features, including (1) Improved efficiency compared to standard approximate Riemann solvers, (2) Robustness under stiff conditions, (3) Accuracy on linear and nonlinear phenomena. In particular it is demonstrated that the framework allows for an efficient weakly implicit implementation, focusing on an accurate resolution of slow transients relevant for the petroleum industry. (author)

  2. Research on the development of advanced system safety assessment procedures (1)

    International Nuclear Information System (INIS)

    Suzuki, Kazuhiko

    2002-02-01

    The past research reports in the area of safety engineering proposed the Computer-aided HAZOP system to be applied to Nuclear Reprocessing Facilities. Automated HAZOP system has great advantage compared with human analysts in terms of accuracy of the results, and time required to conduct HAZOP studies. This report surveys the literature on risk assessment and safety design based on the concept of independent protection layers (IPLs). Furthermore, to improve HAZOP System, counter measures information related to abnormal situation in plants are added to knowledge base in the system. As the result the HAZOP system can give appropriate measures information to protect accidents to uses. Such HAZOP system is applied to analyze the processes, where the ability of the proposed system is verified. (author)

  3. A Demonstration of the System Assessment Capability (SAC) Rev. 1 Software for the Hanford Remediation Assessment Project

    International Nuclear Information System (INIS)

    Eslinger, Paul W.; Kincaid, Charles T.; Nichols, William E.; Wurstner, Signe K.

    2006-01-01

    The System Assessment Capability (SAC) is a suite of interrelated computer codes that provides the capability to conduct large-scale environmental assessments on the Hanford Site. Developed by Pacific Northwest National Laboratory for the Department of Energy, SAC models the fate and transport of radioactive and chemical contaminants, starting with the inventory of those contaminants in waste sites, simulating transport through the environment, and continuing on through impacts to the environment and humans. Separate modules in the SAC address inventory, release from waste forms, water flow and mass transport in the vadose zone, water flow and mass transport in the groundwater, water flow and mass transport in the Columbia River, air transport, and human and ecological impacts. The SAC supports deterministic analyses as well as stochastic analyses using a Monte Carlo approach, enabling SAC users to examine the effect of uncertainties in a number of key parameters. The initial assessment performed with the SAC software identified a number of areas where both the software and the analysis approach could be improved. Since that time the following six major software upgrades have been made: (1) An air pathway model was added to support all-pathway analyses. (2) Models for releases from glass waste forms, buried graphite reactor cores, and buried naval reactor compartments were added. (3) An air-water dual-phase model was added to more accurately track the movement of volatile contaminants in the vadose zone. (4) The ability to run analyses was extended from 1,000 years to 10,000 years or longer after site closure. (5) The vadose zone flow and transport model was upgraded to support two-dimensional or three-dimensional analyses. (6) The ecological model and human risk models were upgraded so the concentrations of contaminants in food products consumed by humans are produced by the ecological model. This report documents the functions in the SAC software and provides a

  4. A Demonstration of the System Assessment Capability (SAC) Rev. 1 Software for the Hanford Remediation Assessment Project

    Energy Technology Data Exchange (ETDEWEB)

    Eslinger, Paul W.; Kincaid, Charles T.; Nichols, William E.; Wurstner, Signe K.

    2006-11-06

    The System Assessment Capability (SAC) is a suite of interrelated computer codes that provides the capability to conduct large-scale environmental assessments on the Hanford Site. Developed by Pacific Northwest National Laboratory for the Department of Energy, SAC models the fate and transport of radioactive and chemical contaminants, starting with the inventory of those contaminants in waste sites, simulating transport through the environment, and continuing on through impacts to the environment and humans. Separate modules in the SAC address inventory, release from waste forms, water flow and mass transport in the vadose zone, water flow and mass transport in the groundwater, water flow and mass transport in the Columbia River, air transport, and human and ecological impacts. The SAC supports deterministic analyses as well as stochastic analyses using a Monte Carlo approach, enabling SAC users to examine the effect of uncertainties in a number of key parameters. The initial assessment performed with the SAC software identified a number of areas where both the software and the analysis approach could be improved. Since that time the following six major software upgrades have been made: (1) An air pathway model was added to support all-pathway analyses. (2) Models for releases from glass waste forms, buried graphite reactor cores, and buried naval reactor compartments were added. (3) An air-water dual-phase model was added to more accurately track the movement of volatile contaminants in the vadose zone. (4) The ability to run analyses was extended from 1,000 years to 10,000 years or longer after site closure. (5) The vadose zone flow and transport model was upgraded to support two-dimensional or three-dimensional analyses. (6) The ecological model and human risk models were upgraded so the concentrations of contaminants in food products consumed by humans are produced by the ecological model. This report documents the functions in the SAC software and provides a

  5. [Assessment of the MF59-adjuvanted pandemic influenza A/H1N1 vaccine. Systematic review of literature].

    Science.gov (United States)

    Ruiz-Aragón, J; Grande Tejada, A M; Márquez-Peláez, S; Molina Linde, J M; Yang, R

    2013-10-01

    To assess the efficacy and safety of MF59-adjuvanted pandemic influenza A/H1N1 vaccine in children. A systematic review of the literature was performed after searching the MedLine and Embase electronic databases, and manual search in specialties journals, with MeSH terms and and free terms. Inclusion criteria were clinical trials with children vaccinated with MF59-adjuvanted influenza A/H1N1 vaccine, compared with other vaccines doses with/without MF59-adjuvanted. The immunogenicity and safety of the vaccine was recorded. The quality of the studies included was assessed by CASPe checklist. Four clinical trials with moderate quality were selected. The local and systemic adverse effects were rare and mild, with no differences between groups. Seroconversion and seroprotection levels were higher with MF59-adjuvanted vaccines. Antibody titres were also higher with the adjuvant vaccines. The adjuvant vaccine has a good efficacy and safety profile. The adverse effects that may occur are common and appear similarly in both vaccination groups. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  6. Human-system interface design review guideline -- Process and guidelines: Final report. Revision 1, Volume 1

    International Nuclear Information System (INIS)

    1996-06-01

    NUREG-0700, Revision 1, provides human factors engineering (HFE) guidance to the US Nuclear Regulatory Commission staff for its: (1) review of the human system interface (HSI) design submittals prepared by licensees or applications for a license or design certification of commercial nuclear power plants, and (2) performance of HSI reviews that could be undertaken as part of an inspection or other type of regulatory review involving HSI design or incidents involving human performance. The guidance consists of a review process and HFE guidelines. The document describes those aspects of the HSI design review process that are important to the identification and resolution of human engineering discrepancies that could adversely affect plant safety. Guidance is provided that could be used by the staff to review an applicant's HSI design review process or to guide the development of an HSI design review plan, e.g., as part of an inspection activity. The document also provides detailed HFE guidelines for the assessment of HSI design implementations. NUREG-0700, Revision 1, consists of three stand-alone volumes. Volume 1 consists of two major parts. Part 1 describes those aspects of the review process of the HSI design that are important to identifying and resolving human engineering discrepancies. Part 2 contains detailed guidelines for a human factors engineering review which identify criteria for assessing the implementation of an applicant's or licensee's HSI design

  7. Tie-down assessment of radioactive material packages on conveyances approach to competent authority approval applications in accordance with TS-R 1 (June 2000) and TS-G-1.1 (June 2002)

    Energy Technology Data Exchange (ETDEWEB)

    Read, J.; Owen, S.; Tso, C.F. [Arup, London (United Kingdom)

    2004-07-01

    This paper summarizes the authors' findings, during carrying out many package tie-down assessments, regarding the approach to the assessment process, and the issues that may arise. The current regulatory framework, as outlined in the abstract, is considered and possible areas for further development or research are discussed. The safe transport of a package containing radioactive material requires a secure system of retention on the conveyance during transport. The requirements for the assessment of this tie-down system are covered by International Atomic Energy Authority (IAEA) Regulations, and by the specific regulatory and guidance materials applying in the country of application. The IAEA regulations have recently been updated in TS-R-1 (June 2000) [1] and TS-G-1.1 (June 2002) [2]. In particular, Appendix V of reference [2] specifically covers 'Package Stowage and Retention during Transport'. In the United Kingdom the Transport Container Standardisation Committee (TCSC) provides guidance on the application of the IAEA regulations in TCSC 1006 ''The securing of Radioactive Materials on Conveyances'' [3], and this document has also been revised in December 2003. The basic requirement of the IAEA regulations is to maintain the integrity of the components of the package and its retention systems during routine operations (TS-R-1 Para 612). In accident conditions the package is permitted and may be required as part of the design (the weak-link approach as discussed later in this paper) to separate from the conveyance, while preserving the package integrity. Any tie-down attachments on the package shall be so designed that, under normal and accident conditions of transport, the forces in those attachments shall not impair the ability of the package to meet the requirements of the Regulations. (TS-R-1 Para 636).

  8. Tie-down assessment of radioactive material packages on conveyances approach to competent authority approval applications in accordance with TS-R 1 (June 2000) and TS-G-1.1 (June 2002)

    International Nuclear Information System (INIS)

    Read, J.; Owen, S.; Tso, C.F.

    2004-01-01

    This paper summarizes the authors' findings, during carrying out many package tie-down assessments, regarding the approach to the assessment process, and the issues that may arise. The current regulatory framework, as outlined in the abstract, is considered and possible areas for further development or research are discussed. The safe transport of a package containing radioactive material requires a secure system of retention on the conveyance during transport. The requirements for the assessment of this tie-down system are covered by International Atomic Energy Authority (IAEA) Regulations, and by the specific regulatory and guidance materials applying in the country of application. The IAEA regulations have recently been updated in TS-R-1 (June 2000) [1] and TS-G-1.1 (June 2002) [2]. In particular, Appendix V of reference [2] specifically covers 'Package Stowage and Retention during Transport'. In the United Kingdom the Transport Container Standardisation Committee (TCSC) provides guidance on the application of the IAEA regulations in TCSC 1006 ''The securing of Radioactive Materials on Conveyances'' [3], and this document has also been revised in December 2003. The basic requirement of the IAEA regulations is to maintain the integrity of the components of the package and its retention systems during routine operations (TS-R-1 Para 612). In accident conditions the package is permitted and may be required as part of the design (the weak-link approach as discussed later in this paper) to separate from the conveyance, while preserving the package integrity. Any tie-down attachments on the package shall be so designed that, under normal and accident conditions of transport, the forces in those attachments shall not impair the ability of the package to meet the requirements of the Regulations. (TS-R-1 Para 636)

  9. DUPIC fuel cycle economics assessment (1)

    International Nuclear Information System (INIS)

    Choi, H. B.; Roh, G. H.; Kim, D. H.

    1999-04-01

    This is a state-of-art report that describes the current status of the DUPIC fuel cycle economics analysis conducted by the DUPIC fuel compatibility assessment group of the DUPIC fuel development project. For the DUPIC fuel cycle economics analysis, the DUPIC fuel compatibility assessment group has organized the 1st technical meeting composed of 8 domestic specialists from government, academy, industry, etc. and a foreign specialist of hot-cell design from TRI on July 16, 1998. This report contains the presentation material of the 1st technical meeting, published date used for the economics analysis and opinions of participants, which could be utilized for further DUPIC fuel cycle and back-end fuel cycle economics analyses. (author). 11 refs., 7 charts

  10. Assessment of TRAC-BF1 1D reflood model with CCTF and SCTF data

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Ohnuki, Akira; Murao, Yoshio; Abe, Yutaka.

    1993-03-01

    Post test calculations for six selected Cylindrical Core Test Facility (CCTF) and Slab Core Test Facility (SCTF) tests were performed to assess the core thermal hydraulic models of the TRAC-BF1 code during the reflood in a PWR LOCA. A special version of the TRAC code was developed at JAERI by implementing the constitutive package of the TRAC-BF1 code into the TRAC-PF1 code for this assessment. The TRAC-BF1 model predicted well the void fraction at either bottom or top part of the core and overpredicted the void fraction at the center part of the core in the CCTF and SCTF tests performed under so-called licensing conditions. The TRAC-BF1 model overpredicted the clad temperatures at the center part of the core. The TRAC-BF1 model predicted a jump of void fraction where the flow pattern transition between the bubbly/slug flow and the annular/dispersed flow regimes occurred. The jump caused the water mass flow rate to be unstable and resulted in the overprediction of the void fraction at the center part of the core. It was also found that the TRAC-BF1 film boiling model underestimated the heat transfer coefficient in the vicinity of the quench front and caused the quench front propagation to be delayed. These assessment results suggest the following areas should be improved in future to apply the TRAC-BF1 code to the reflood in a PWR LOCA: (1) Core hydraulic model where flow pattern transition occurs, (2) Core heat transfer model in the film boiling regime, especially for the dependence on the distance from the quench front. (author)

  11. Assessing health systems for type 1 diabetes in sub-Saharan Africa: developing a 'Rapid Assessment Protocol for Insulin Access'

    Directory of Open Access Journals (Sweden)

    de Courten Maximilian

    2006-02-01

    Full Text Available Abstract Background In order to improve the health of people with Type 1 diabetes in developing countries, a clear analysis of the constraints to insulin access and diabetes care is needed. We developed a Rapid Assessment Protocol for Insulin Access, comprising a series of questionnaires as well as a protocol for the gathering of other data through site visits, discussions, and document reviews. Methods The Rapid Assessment Protocol for Insulin Access draws on the principles of Rapid Assessment Protocols which have been developed and implemented in several different areas. This protocol was adapted through a thorough literature review on diabetes, chronic condition management and medicine supply in developing countries. A visit to three countries in sub-Saharan Africa and meetings with different experts in the field of diabetes helped refine the questionnaires. Following the development of the questionnaires these were tested with various people familiar with diabetes and/or healthcare in developing countries. The Protocol was piloted in Mozambique then refined and had two further iterations in Zambia and Mali. Translations of questionnaires were made into local languages when necessary, with back translation to ensure precision. Results In each country the protocol was implemented in 3 areas – the capital city, a large urban centre and a predominantly rural area and their respective surroundings. Interviews were carried out by local teams trained on how to use the tool. Data was then collected and entered into a database for analysis. Conclusion The Rapid Assessment Protocol for Insulin Access was developed to provide a situational analysis of Type 1 diabetes, in order to make recommendations to the national Ministries of Health and Diabetes Associations. It provided valuable information on patients' access to insulin, syringes, monitoring and care. It was thus able to sketch a picture of the health care system with regards to its ability to

  12. TRAC-PF1/MOD1 assessment at Los Alamos

    International Nuclear Information System (INIS)

    Knight, T.D.

    1984-01-01

    The Los Alamos National Laboratory is developing the Transient Reactor Analysis Code (TRAC) to provide an advanced best-estimate predictive capability for the analysis of postulated accidents in pressurized water reactors (PWRs). Over the past several years, four distinct versions of the code have been released; each new version introduced improvements to the existing models and numerics and added new models to extend the applications of the code. The first goal of the code was to analyze large-break loss-of-coolant accidents (LOCAs), and the TRAC-P1A and TRAC-PD2 codes primarily addressed the large-break LOCA. (The TRAC-PD2/MOD1 code is essentially the same as the TRAC-PD2 code but it also includes a released set of error corrections.) The TRAC-PF1 code contained major changes to the models and trips and to the numerical methods. These modifications enhanced the computational speed of the code and improved the application to small-break LOCAs. The TRAC-PF1/MOD1 code, the latest released version, added improved steam-generator modeling, a turbine component, and a control system together with modified constitutive relations to model the balance of plant on the secondary side and to extend the applications to non-LOCA transients. The TRAC-PF1/MOD1 code also contains reasonably general reactor-kinetics modeling to facilitate the simulation of transients with delayed scram or without scram. 13 references, 24 figures

  13. Technical Assessment: WRAP 1 HVAC Passive Shutdown

    International Nuclear Information System (INIS)

    Ball, D.E.; Nash, C.R.; Stroup, J.L.

    1993-01-01

    As the result of careful interpretation of DOE Order 6430.lA and other DOE Orders, the HVAC system for WRAP 1 has been greatly simplified. The HVAC system is now designed to safely shut down to Passive State if power fails for any reason. The fans cease functioning, allowing the Zone 1 and Zone 2 HVAC Confinement Systems to breathe with respect to atmospheric pressure changes. Simplifying the HVAC system avoided overdesign. Construction costs were reduced by eliminating unnecessary equipment. This report summarizes work that was done to define the criteria, physical concepts, and operational experiences that lead to the passive shutdown design for WRAP 1 confinement HVAC systems

  14. Development of a calibration system for airborne "1"3"1I monitoring devices

    International Nuclear Information System (INIS)

    Zhao, C.; Tang, F.; He, L.; Xu, Y.; Lu, X.

    2016-01-01

    A prototype calibration system for airborne "1"3"1I monitoring devices was developed at the Shanghai Institute of Measurement and Testing Technology (SIMT). This system consists of a gaseous "1"3"1I_2 generator, an airborne storage chamber, an airborne iodine sampler, and an HPGe spectrometer. With this system, "1"3"1I reference samples in the form of charcoal filters and charcoal cartridges, with activities ranging from 100 to 10,000 Bq, were produced with overall relative standard uncertainties of 2.8% (for filter samples) and 3.5% (for cartridge samples); the activities range could be extended according to need. - Highlights: • Original calibration system for airborne "1"3"1I monitoring devices was developed. • Two types of "1"3"1I reference samples was prepared. • The activity of the produced "1"3"1I reference sample could be easily controlled. • The influence of uneven distribution of "1"3"1I in cartridge samples was considered.

  15. Integrity Assessment of Essential Service Water System of Ulchin unit 1 and 2

    International Nuclear Information System (INIS)

    Lee, Sun Ki; Lee, Sang Kook; Jeong, Il Suk; Song, Taek Ho; Kwon, Jong Ju; Hong, Seong Yul; Lee, Jin Hwan

    2005-01-01

    Because of circulating water filtration system(CFI) and essential service water system(SEC) of Ulchin unit 1 and 2 were designed by commonness water intake structure, circulating water filtration system is managed by quality grade Q class. In this study, circulating water filtration system (CFI) examined revision possibility from present quality grade Q class to R class. It is proving that the operation of essential service water system (SEC) is always available regardless CFI conditions

  16. Masses and decay constants of D(s) * and B(s) * mesons with Nf=2 +1 +1 twisted mass fermions

    Science.gov (United States)

    Lubicz, V.; Melis, A.; Simula, S.; ETM Collaboration

    2017-08-01

    We present a lattice calculation of the masses and decay constants of D(s) * and B(s) * mesons using the gauge configurations produced by the European Twisted Mass Collaboration (ETMC) with Nf=2 +1 +1 dynamical quarks at three values of the lattice spacing a ˜(0.06 -0.09 ) fm . Pion masses are simulated in the range Mπ≃(210 - 450 ) MeV , while the strange and charm sea-quark masses are close to their physical values. We compute the ratios of vector to pseudoscalar masses and decay constants for various values of the heavy-quark mass mh in the range 0.7 mcphys≲mh≲3 mcphys . In order to reach the physical b -quark mass, we exploit the heavy quark effective theory prediction that, in the static limit of infinite heavy-quark mass, the considered ratios are equal to one. At the physical point our results are MD*/MD=1.0769 (79 ) , MDs*/MDs=1.0751(56 ), fD*/fD=1.078 (36 ), fDs*/fD s=1.087 (20 ), MB*/MB=1.0078 (15 ), MBs*/MBs=1.0083(10 ), fB*/fB=0.958 (22 ) and fBs*/fB s=0.974 (10 ). Combining them with the experimental values of the pseudoscalar meson masses (used as input to fix the quark masses) and the values of the pseudoscalar decay constants calculated by ETMC, we get MD*=2013 (14 ), MDs*=2116 (11 ), fD*=223.5 (8.4 ), fDs*=268.8 (6.6 ), MB*=5320.5 (7.6 ), MBs*=5411.36 (5.3 ), fB*=185.9 (7.2 ) and fBs*=223.1 (5.4 ) MeV .

  17. Executive Summary -- assessment of undiscovered oil and gas resources of the San Joaquin Basin Province of California, 2003: Chapter 1 in Petroleum systems and geologic assessment of oil and gas in the San Joaquin Basin Province, California

    Science.gov (United States)

    Gautier, Donald L.; Scheirer, Allegra Hosford; Tennyson, Marilyn E.; Peters, Kenneth E.; Magoon, Leslie B.; Lillis, Paul G.; Charpentier, Ronald R.; Cook, Troy A.; French, Christopher D.; Klett, Timothy R.; Pollastro, Richard M.; Schenk, Christopher J.

    2007-01-01

    In 2003, the U.S. Geological Survey (USGS) completed an assessment of the oil and gas resource potential of the San Joaquin Basin Province of California (fig. 1.1). The assessment is based on the geologic elements of each Total Petroleum System defined in the province, including hydrocarbon source rocks (source-rock type and maturation and hydrocarbon generation and migration), reservoir rocks (sequence stratigraphy and petrophysical properties), and hydrocarbon traps (trap formation and timing). Using this geologic framework, the USGS defined five total petroleum systems and ten assessment units within these systems. Undiscovered oil and gas resources were quantitatively estimated for the ten assessment units (table 1.1). In addition, the potential was estimated for further growth of reserves in existing oil fields of the San Joaquin Basin.

  18. Diagnostic value of fibronectin discriminant score for predicting liver fibrosis stages in chronic hepatitis C virus patients.

    Science.gov (United States)

    Attallah, Abdelfattah M; Abdallah, Sanaa O; Attallah, Ahmed A; Omran, Mohamed M; Farid, Khaled; Nasif, Wesam A; Shiha, Gamal E; Abdel-Aziz, Abdel-Aziz F; Rasafy, Nancy; Shaker, Yehia M

    2013-01-01

    Several noninvasive predictive models were developed to substitute liver biopsy for fibrosis assessment. To evaluate the diagnostic value of fibronectin which reflect extracellular matrix metabolism and standard liver functions tests which reflect alterations in hepatic functions. Chronic hepatitis C (CHC) patients (n = 145) were evaluated using ROC curves and stepwise multivariate discriminant analysis (MDA) and was validated in 180 additional patients. Liver biochemical profile including transaminases, bilirubin, alkaline phosphatase, albumin, complete blood count were estimated. Fibronectin concentration was determined using monoclonal antibody and ELISA. A novel index named fibronectin discriminant score (FDS) based on fibronectin, APRI and albumin was developed. FDS produced areas under ROC curves (AUC) of 0.91 for significant fibrosis and 0.81 for advanced fibrosis. The FDS correctly classified 79% of the significant liver fibrosis patients (F2-F4) with 87% sensitivity and 75% specificity. The relative risk [odds ratio (OR)] of having significant liver fibrosis using the cut-off values determined by ROC curve analyses were 6.1 for fibronectin, 4.9 for APRI, and 4.2 for albumin. FDS predicted liver fibrosis with an OR of 16.8 for significant fibrosis and 8.6 for advanced fibrosis. The FDS had similar AUC and OR in the validation group to the estimation group without statistically significant difference. FDS predicted liver fibrosis with high degree of accuracy, potentially decreasing the number of liver biopsy required.

  19. Human-system interface design review guideline -- Process and guidelines: Final report. Revision 1, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-06-01

    NUREG-0700, Revision 1, provides human factors engineering (HFE) guidance to the US Nuclear Regulatory Commission staff for its: (1) review of the human system interface (HSI) design submittals prepared by licensees or applications for a license or design certification of commercial nuclear power plants, and (2) performance of HSI reviews that could be undertaken as part of an inspection or other type of regulatory review involving HSI design or incidents involving human performance. The guidance consists of a review process and HFE guidelines. The document describes those aspects of the HSI design review process that are important to the identification and resolution of human engineering discrepancies that could adversely affect plant safety. Guidance is provided that could be used by the staff to review an applicant`s HSI design review process or to guide the development of an HSI design review plan, e.g., as part of an inspection activity. The document also provides detailed HFE guidelines for the assessment of HSI design implementations. NUREG-0700, Revision 1, consists of three stand-alone volumes. Volume 1 consists of two major parts. Part 1 describes those aspects of the review process of the HSI design that are important to identifying and resolving human engineering discrepancies. Part 2 contains detailed guidelines for a human factors engineering review which identify criteria for assessing the implementation of an applicant`s or licensee`s HSI design.

  20. Life Cycle Assessment of waste management systems in Italian industrial areas: Case study of 1st Macrolotto of Prato

    International Nuclear Information System (INIS)

    Tarantini, Mario; Loprieno, Arianna Dominici; Cucchi, Eleonora; Frenquellucci, Ferdinando

    2009-01-01

    Life Cycle Assessment (LCA) is not widely used as a decision-supporting tool in Italy, despite recent European Commission policies fostering its adoption to achieve an energy- and resource-efficient economy. In this paper, an LCA of waste management system of the 1st Macrolotto industrial area is presented. The aims of the study were to identify the environmental critical points of the system and to evaluate opportunities and problems in applying this methodology at industrial area level. After a description of the waste management system of the 1st Macrolotto industrial area, the main assumptions of the study and some elements of the system modelling are presented. Results confirmed that door-to-door separated collection and packaging recycling are successful strategies for reducing the use of natural resources. The cooperation of the waste management company, which was part of the area management structure, was strategic for the completion of the analysis. Country-specific databases and models should be developed for a widespread application of the LCA methodology to waste management in Italian industrial areas.

  1. Risk Assessment of the Main Control Room Fire Using Fire Simulations

    International Nuclear Information System (INIS)

    Kang, Dae Il; Kim, Kilyoo; Jang, Seung Cheol

    2013-01-01

    KAERI is performing a fire PSA for a reference plant, Ulchin Unit 3, as part of developing the Korean site risk profile (KSRP). Fire simulations of the MCR fire were conducted using the CFAST (Consolidated Fire Growth and Smoke Transport) model and FDS (fire dynamic simulator) to improve the uncertainty in the MCR fire risk analysis. Using the fire simulation results, the MCR abandonment risk was evaluated. Level 1 PSA (probabilistic safety assessment) results of Ulchin Unit 3 using the EPRI PRA (probabilistic risk assessment) implementation guide showed that the MCR (main control room) fire was the main contributor to the core damage frequency. Recently, U. S. NRC and EPRI developed NUREG/CR-6850 to provide state-of-the-art methods, tools, and data for the conduct of a fire PSA for a commercial NPP

  2. An audit of cavity and crown preparations and two direct restorations carried out by foundation dentists in the Oxford and Wessex Deaneries.

    Science.gov (United States)

    Burke, F J T; Mackenzie, L; Falcon, H; Priest, N; Palin, W M

    2014-04-01

    It is likely that many foundation dentists (FDs) will have completed only minimal amounts of restorative dentistry for a number of months immediately prior to commencing work as FDs. Thus this audit aimed to assess the performance of the FDs when they carried out a number of simulated clinical exercises: amalgam cavities and restoration; Class IV resin composite restorations; and full crown preparations for metal-ceramic restorations. A total of 67 FDs completed the assessments and some results did indicate a high level of concern and need for further evaluation of restorative practice.

  3. Fiber optic-based fluorescence detection system for in vivo studies of exogenous chromophore pharmacokinetics

    Science.gov (United States)

    Doiron, Daniel R.; Dunn, J. B.; Mitchell, W. L.; Dalton, Brian K.; Garbo, Greta M.; Warner, Jon A.

    1995-05-01

    The detection and quantification of the concentration of exogenous chromophores in-vivo by their fluorescence is complicated by many physical and geometrical parameters. Measurement of such signals is advantageous in determining the pharmacokinetics of photosensitizers such as those used in photodynamic therapy (PDT) or to assist in the diagnosis of tissue histological state. To overcome these difficulties a ratio based fiber optic contact fluorometer has been developed. This fluorescence detection system (FDS) uses the ratio of the fluorescence emission peak of the exogenous chromophore to that of endogenous chromophores, i.e. autofluorescence, to correct for a variety of parameters affecting the magnitude of the measured signals. By doing so it also minimizes the range of baseline measurements prior to exogenous drug injection, for various tissue types. Design of the FDS and results of its testing in animals and patients using the second generation photosensitizer Tin ethyletiopurpurin (SnET2) are presented. These results support the feasibility and usefulness of the Ratio FDS system.

  4. The MCNP Simulation of a PGNAA System at TRR-1/M1

    Science.gov (United States)

    Sangaroon, S.; Ratanatongchai, W.; Picha, R.; Khaweerat, S.; Channuie, J.

    2017-06-01

    The prompt-gamma neutron activation analysis system (PGNAA) has been installed at Thai Research Reactor-1/Modified 1 (TRR-1/M1) since 1999. The purpose of the system is for elemental and isotopic analyses. The system mainly consists of a series of the moderator and collimator, neutron and gamma-ray shielding and the HPGe detector. In this work, the condition of the system is carried out based on the Monte Carlo method using Monte Carlo N-Particle transport code and the experiment. The flux ratios (Φthermal/Φepithermal and Φthermal/Φfast) and thermal neutron flux have been obtained. The simulated prompt gamma rays of the Portland cement sample have been carried out. The simulation provides significant contribution in upgrading the PGNAA station to be available in various applications.

  5. Dynamic cell culture system (7-IML-1)

    Science.gov (United States)

    Cogoli, Augusto

    1992-01-01

    This experiment is one of the Biorack experiments being flown on the International Microgravity Laboratory 1 (MIL-1) mission as part of an investigation studying cell proliferation and performance in space. One of the objectives of this investigation is to assess the potential benefits of bioprocessing in space with the ultimate goal of developing a bioreactor for continuous cell cultures in space. This experiment will test the operation of an automated culture chamber that was designed for use in a Bioreactor in space. The device to be tested is called the Dynamic Cell Culture System (DCCS). It is a simple device in which media are renewed or chemicals are injected automatically, by means of osmotic pumps. This experiment uses four Type I/O experiment containers. One DCCS unit, which contains a culture chamber with renewal of medium and a second chamber without a medium supply fits in each container. Two DCCS units are maintained under zero gravity conditions during the on-orbit period. The other two units are maintained under 1 gh conditions in a 1 g centrifuge. The schedule for incubator transfer is given.

  6. River Protection Project information systems assessment

    International Nuclear Information System (INIS)

    JOHNSON, A.L.

    1999-01-01

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report

  7. NASA Controller Acceptability Study 1(CAS-1) Experiment Description and Initial Observations

    Science.gov (United States)

    Chamberlain, James P.; Consiglio, Maria C.; Comstock, James R., Jr.; Ghatas, Rania W.; Munoz, Cesar

    2015-01-01

    This paper describes the Controller Acceptability Study 1 (CAS-1) experiment that was conducted by NASA Langley Research Center personnel from January through March 2014 and presents partial CAS-1 results. CAS-1 employed 14 air traffic controller volunteers as research subjects to assess the viability of simulated future unmanned aircraft systems (UAS) operating alongside manned aircraft in moderate-density, moderate-complexity Class E airspace. These simulated UAS were equipped with a prototype pilot-in-the-loop (PITL) Detect and Avoid (DAA) system, specifically the Self-Separation (SS) function of such a system based on Stratway+ software to replace the see-and-avoid capabilities of manned aircraft pilots. A quantitative CAS-1 objective was to determine horizontal miss distance (HMD) values for SS encounters that were most acceptable to air traffic controllers, specifically HMD values that were assessed as neither unsafely small nor disruptively large. HMD values between 0.5 and 3.0 nautical miles (nmi) were assessed for a wide array of encounter geometries between UAS and manned aircraft. The paper includes brief introductory material about DAA systems and their SS functions, followed by descriptions of the CAS-1 simulation environment, prototype PITL SS capability, and experiment design, and concludes with presentation and discussion of partial CAS-1 data and results.

  8. Defense Enterprise Accounting and Management System-Increment 1 (DEAMS Inc 1)

    Science.gov (United States)

    2016-03-01

    information accurately and in conformance with Generally Accepted Accounting Principles , to comply with Congressional requirements of the Chief Financial ...2016 Major Automated Information System Annual Report Defense Enterprise Accounting and Management System-Increment 1 (DEAMS Inc 1) Defense...Phone: 937-257-2714 Fax: DSN Phone: 787-2714 DSN Fax: Date Assigned: August 17, 2015 Program Information Program Name Defense Enterprise Accounting

  9. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.; Rohatgi, U.S.

    1995-01-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations al these conditions were compared with the GIRAFFE data. The effects of PCCS cell nodings on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to ±5% of the data with a three-node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer in the presence of noncondensable gases with only a coarse mesh. The cell length term in the condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes

  10. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.

    1995-01-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to ±5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes

  11. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C. [and others

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {plus_minus}5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  12. Introduction of Sodium Fire Extinguishing System for STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Gam, Dayoung; Kim, Jong-Man; Jung, Min-Hwan; Eoh, Jae-Hyuk; Jeong, Eoh Jiyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This characteristic is a big advantage as a thermal transfer fluid. However, the high reactivity of sodium, especially with water and oxygen, and white aerosol in the event of fire can cause serious accidents. Thus, large sodium facility needs a specific-developed fire extinguishing system for a safe experiment. Korea Atomic Energy Research Institute (KAERI) has conducted sodium heat transfer experiments using the facility named the Sodium Integral Effect Test Loop for Safety Simulation and Assessment (STELLA-1). STELLA-1 fully equipped a sodium fire extinguishing system for the safe experiment and fire spread prevention. In this paper, a preparation of the fire extinguishing system of STELLA-1 facility is introduced. This paper can provide an example of how to design a sodium fire extinguishing system for a large sodium experiment facility. In this paper, a preparation of the fire extinguishment system for STELLA-1 as a large sodium experiment facility was introduced and explained. For safe operation of the liquid sodium utility, it is important to equip specific-developed fire extinguishing system because of the chemical characteristics of sodium. Operators should know the process and operating manual before conducting an experiment to prevent hazardous situation. Though the dry chemical extinguishing agent put out the fire target, removing agent at high temperature state can cause re-combustion. Thus, extinguishment confirmation work should be conducted after sufficient cooling time to stabilize the surface. And in case of fire at a sealed room, a method making the percentage of oxygen low(injecting nitrogen gas or argon gas) is effective.

  13. Introduction of Sodium Fire Extinguishing System for STELLA-1

    International Nuclear Information System (INIS)

    Gam, Dayoung; Kim, Jong-Man; Jung, Min-Hwan; Eoh, Jae-Hyuk; Jeong, Eoh Jiyoung

    2015-01-01

    This characteristic is a big advantage as a thermal transfer fluid. However, the high reactivity of sodium, especially with water and oxygen, and white aerosol in the event of fire can cause serious accidents. Thus, large sodium facility needs a specific-developed fire extinguishing system for a safe experiment. Korea Atomic Energy Research Institute (KAERI) has conducted sodium heat transfer experiments using the facility named the Sodium Integral Effect Test Loop for Safety Simulation and Assessment (STELLA-1). STELLA-1 fully equipped a sodium fire extinguishing system for the safe experiment and fire spread prevention. In this paper, a preparation of the fire extinguishing system of STELLA-1 facility is introduced. This paper can provide an example of how to design a sodium fire extinguishing system for a large sodium experiment facility. In this paper, a preparation of the fire extinguishment system for STELLA-1 as a large sodium experiment facility was introduced and explained. For safe operation of the liquid sodium utility, it is important to equip specific-developed fire extinguishing system because of the chemical characteristics of sodium. Operators should know the process and operating manual before conducting an experiment to prevent hazardous situation. Though the dry chemical extinguishing agent put out the fire target, removing agent at high temperature state can cause re-combustion. Thus, extinguishment confirmation work should be conducted after sufficient cooling time to stabilize the surface. And in case of fire at a sealed room, a method making the percentage of oxygen low(injecting nitrogen gas or argon gas) is effective

  14. Assessment of effectiveness of geologic isolation systems. CIRMIS data system. Volume 1. Initialization, operation, and documentation

    International Nuclear Information System (INIS)

    Friedrichs, D.R.

    1980-01-01

    The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for use by the hydrologic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System, a storage and retrieval system for model input and output data, including graphical interpretation and display is described. This is the first of four volumes of the description of the CIRMIS Data System

  15. Quality improvement competency gaps in primary care in Albanian, polish and slovenian contexts: a study protocol.

    Science.gov (United States)

    Czabanowska, Katarzyna; Burazeri, Genc; Klemenc-Ketis, Zalika; Kijowska, Violetta; Tomasik, Tomasz; Brand, Helmut

    2012-12-01

    Nowadays, general practitioners (GPs) and family doctors (FDs) face increasing demands, as a consequence of complex patients' expectations, developments in science and technology, and limitations within healthcare systems which can result in competency gaps. Therefore, there is a need to identify which competencies in quality improvement (QI) are most important for GPs and FDs to possess in order to meet the demands of contemporary health care practice. To date, however, little information is available on the self-assessment of competencies related to QI among GPs and FDs. To deal with these issues, a project on QI in continuous medical education was launched in 2011. The project aims to broaden the GPs'/ FDs' continuous education offer, its quality and attractiveness, as well as provide them with opportunities for vocational advancement and enable the development of common, European frame of reference for GPs'/FDs' occupational competencies. The third work package of the project consists of the validation research of the questionnaire developed on the basis of the competency framework in QI for GPs/FDs in Europe. A cross-sectional study will be carried out using the self-assessment QI questionnaire which was originally developed in English and subsequently it was cross-culturally adapted in Slovenian, Albanian and Polish settings by use of a pilot study on a conveniently selected group of FDs/GPs (N=10) in each participating country. The final version of the questionnaire will be administered to large samples in each country involved in the survey. Two weeks after the first administration of the questionnaire, a second round, with the same procedure and including the same group of respondents, will follow. Psychometric tests will be conducted including internal consistency (after the initial and subsequent application of the instrument) and stability over time (two-week test-retest reliability). This self-assessment study will demonstrate the complex environment

  16. 46 CFR 111.107-1 - Industrial systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial systems. 111.107-1 Section 111.107-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Industrial Systems § 111.107-1 Industrial systems. (a) For the purpose of this subpart, an...

  17. Space Launch Systems Block 1B Preliminary Navigation System Design

    Science.gov (United States)

    Oliver, T. Emerson; Park, Thomas; Anzalone, Evan; Smith, Austin; Strickland, Dennis; Patrick, Sean

    2018-01-01

    NASA is currently building the Space Launch Systems (SLS) Block 1 launch vehicle for the Exploration Mission 1 (EM-1) test flight. In parallel, NASA is also designing the Block 1B launch vehicle. The Block 1B vehicle is an evolution of the Block 1 vehicle and extends the capability of the NASA launch vehicle. This evolution replaces the Interim Cryogenic Propulsive Stage (ICPS) with the Exploration Upper Stage (EUS). As the vehicle evolves to provide greater lift capability, increased robustness for manned missions, and the capability to execute more demanding missions so must the SLS Integrated Navigation System evolved to support those missions. This paper describes the preliminary navigation systems design for the SLS Block 1B vehicle. The evolution of the navigation hard-ware and algorithms from an inertial-only navigation system for Block 1 ascent flight to a tightly coupled GPS-aided inertial navigation system for Block 1B is described. The Block 1 GN&C system has been designed to meet a LEO insertion target with a specified accuracy. The Block 1B vehicle navigation system is de-signed to support the Block 1 LEO target accuracy as well as trans-lunar or trans-planetary injection accuracy. Additionally, the Block 1B vehicle is designed to support human exploration and thus is designed to minimize the probability of Loss of Crew (LOC) through high-quality inertial instruments and robust algorithm design, including Fault Detection, Isolation, and Recovery (FDIR) logic.

  18. Corrosion critique of the 2 1/4 Cr--1 Mo steel for LMFBR steam generation system applications

    International Nuclear Information System (INIS)

    Zima, G.E.

    1977-07-01

    The unstabilized ferritic steel of nominal composition, 2 1 / 4 Cr-1Mo, has been proposed for critical structural assignments in LMFBR powerplants, specifically: the tubing, tubesheet and shell of the evaporator and superheater components. The interest in this steel has been based on a presumably favorable general corrosion property spectrum, acceptable mechanical properties and fabricability, and certain economies associated with the low alloy content. This report is an attempt at a general corrosion assessment for the 2 1 / 4 Cr-1Mo steel and an identification of corrosion problem areas potential to this steel from the sodium and water/steam systems of the proposed working environment. There is a considerable area of uncertainty in the sodium-side response of 2 1 / 4 Cr-1Mo steel, centered in the loss and redisposition of carbon during long-term exposure to sodium of various impurity backgrounds. It is submitted that present evidence relating to the water/steam-side corrosion behavior of the 2 1 / 4 Cr-1Mo steel, under nominal and conceivable perturbed environmental conditions, constitutes the principal concern for the proposed LMFBR powerplant applications of this steel. It is suggested that this unfavorable corrosion aspect represents an inherent limitation of the low alloy content of this steel, probably largely independent of melting and processing recourses, and it is a sufficient basis to question the incentive for a continuation of the collateral studies of this steel for the proposed LMFBR steam generation system assignments

  19. 30 CFR 75.1404-1 - Braking system.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Braking system. 75.1404-1 Section 75.1404-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips § 75.1404-1 Braking system. A locomotive equipped with a dual braking system will be deemed to satisfy the requirements of § 75.1404 for a...

  20. The nigrostriatal dopamine system of aging GFRα-1 heterozygous mice: neurochemistry, morphology and behavior

    Science.gov (United States)

    Zaman, Vandana; Boger, Heather A.; Granholm, Ann-Charlotte; Rohrer, Baerbel; Moore, Alfred; Buhusi, Mona; Gerhardt, Greg A.; Hoffer, Barry J.; Middaugh, Lawrence D.

    2009-01-01

    Given the established importance of glial cell line-derived neurotrophic factor (GDNF) in maintaining dopaminergic neurotransmitter systems, the nigrostriatal system and associated behaviors of mice with genetic reduction of its high-affinity receptor, GDNF receptor (GFR)α-1 (GFRα-1+/−), were compared with wild-type controls. Motor activity and the stimulatory effects of a dopamine (DA) D1 receptor agonist (SKF 82958) were assessed longitudinally at 8 and 18 months of age. Monoamine concentrations and dopaminergic nerve terminals in the striatum and the number of dopaminergic neurons in the substantia nigra (SN) were assessed. The results support the importance of GFRα-1 in maintaining normal function of the nigrostriatal dopaminergic system, with deficits being observed for GFRα-1+/− mice at both ages. Motor activity was lower and the stimulatory effects of the DA agonist were enhanced for the older GFRα-1+/− mice. DA in the striatum was reduced in the GFRα-1+/− mice at both ages, and tyrosine hydroxylase-positive cell numbers in the SN were reduced most substantially in the older GFRα-1+/− mice. The combined behavioral, pharmacological probe, neurochemical and morphological measures provide evidence of abnormalities in GFRα-1+/− mice that are indicative of an exacerbated aging-related decline in dopaminergic system function. The noted deficiencies, in turn, suggest that GFRα-1 is necessary for GDNF to maintain normal function of the nigrostriatal dopaminergic system. Although the precise mechanism(s) for the aging-related changes in the dopaminergic system remain to be established, the present study clearly establishes that genetic reductions in GFRα-1 can contribute to the degenerative changes observed in this system during the aging process. PMID:18973577

  1. Spatial distribution of cannabinoid receptor type 1 (CB1 in normal canine central and peripheral nervous system.

    Directory of Open Access Journals (Sweden)

    Jessica Freundt-Revilla

    Full Text Available The endocannabinoid system is a regulatory pathway consisting of two main types of cannabinoid receptors (CB1 and CB2 and their endogenous ligands, the endocannabinoids. The CB1 receptor is highly expressed in the central and peripheral nervous systems (PNS in mammalians and is involved in neuromodulatory functions. Since endocannabinoids were shown to be elevated in cerebrospinal fluid of epileptic dogs, knowledge about the species specific CB receptor expression in the nervous system is required. Therefore, we assessed the spatial distribution of CB1 receptors in the normal canine CNS and PNS. Immunohistochemistry of several regions of the brain, spinal cord and peripheral nerves from a healthy four-week-old puppy, three six-month-old dogs, and one ten-year-old dog revealed strong dot-like immunoreactivity in the neuropil of the cerebral cortex, Cornu Ammonis (CA and dentate gyrus of the hippocampus, midbrain, cerebellum, medulla oblongata and grey matter of the spinal cord. Dense CB1 expression was found in fibres of the globus pallidus and substantia nigra surrounding immunonegative neurons. Astrocytes were constantly positive in all examined regions. CB1 labelled neurons and satellite cells of the dorsal root ganglia, and myelinating Schwann cells in the PNS. These results demonstrate for the first time the spatial distribution of CB1 receptors in the healthy canine CNS and PNS. These results can be used as a basis for further studies aiming to elucidate the physiological consequences of this particular anatomical and cellular distribution.

  2. The Endocannabinoid System across Postnatal Development in Transmembrane Domain Neuregulin 1 Mutant Mice

    Directory of Open Access Journals (Sweden)

    Rose Chesworth

    2018-02-01

    Full Text Available The use of cannabis is a well-established component risk factor for schizophrenia, particularly in adolescent individuals with genetic predisposition for the disorder. Alterations to the endocannabinoid system have been found in the prefrontal cortex of patients with schizophrenia. Thus, we assessed whether molecular alterations exist in the endocannabinoid signalling pathway during brain development in a mouse model for the schizophrenia risk gene neuregulin 1 (Nrg1. We analysed transcripts encoding key molecules of the endocannabinoid system in heterozygous transmembrane domain Nrg1 mutant mice (Nrg1 TM HET, which is known to have increased sensitivity to cannabis exposure. Tissue from the prelimbic cortex and hippocampus of male and female Nrg1 TM HET mice and wild type-like littermates was collected at postnatal days (PNDs 7, 10, 14, 21, 28, 35, 49, and 161. Quantitative polymerase chain reaction was conducted to assess mRNA levels of cannabinoid receptor 1 (CB1R and enzymes for the synthesis and breakdown of the endocannabinoid 2-arachidonoylglycerol [i.e., diacylglycerol lipase alpha (DAGLα, monoglyceride lipase (MGLL, and α/β-hydrolase domain-containing 6 (ABHD6]. No sex differences were found for any transcripts in either brain region; thus, male and female data were pooled. Hippocampal and cortical mRNA expression of DAGLα, MGLL, and ABHD6 increased until PND 21–35 and then decreased and stabilised for the rest of postnatal development. Hippocampal CB1R mRNA expression increased until PND 21 and decreased after this age. Expression levels of these endocannabinoid markers did not differ in Nrg1 TM HET compared to control mice at any time point. Here, we demonstrate dynamic changes in the developmental trajectory of several key endocannabinoid system transcripts in the mouse brain, which may correspond with periods of endocannabinoid system maturation. Nrg1 TM HET mutation did not alter the developmental trajectory of the

  3. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

  4. Assessing the Multiple Benefits of Clean Energy Chapter 1: Introduction

    Science.gov (United States)

    Chapter 1 of “Assessing the Multiple Benefits of Clean Energy” provides an introduction to the document. /meta name=DC.title content=Assessing the Multiple Benefits of Clean Energy Chapter 1: Introduction

  5. River Protection Project information systems assessment

    Energy Technology Data Exchange (ETDEWEB)

    JOHNSON, A.L.

    1999-07-28

    The Information Systems Assessment Report documents the results from assessing the Project Hanford Management Contract (PHMC) Hanford Data Integrator 2000 (HANDI 2000) system, Business Management System (BMS) and Work Management System phases (WMS), with respect to the System Engineering Capability Assessment Model (CAM). The assessment was performed in accordance with the expectations stated in the fiscal year (FY) 1999 Performance Agreement 7.1.1, item (2) which reads, ''Provide an assessment report on the selected Integrated Information System by July 31, 1999.'' This report assesses the BMS and WMS as implemented and planned for the River Protection Project (RPP). The systems implementation is being performed under the PHMC HANDI 2000 information system project. The project began in FY 1998 with the BMS, proceeded in FY 1999 with the Master Equipment List portion of the WMS, and will continue the WMS implementation as funding provides. This report constitutes an interim quality assessment providing information necessary for planning RPP's information systems activities. To avoid confusion, HANDI 2000 will be used when referring to the entire system, encompassing both the BMS and WMS. A graphical depiction of the system is shown in Figure 2-1 of this report.

  6. New Exact Solutions for (1 + 1)-Dimensional Dispersion-Less System

    International Nuclear Information System (INIS)

    Naranmandula; Hu Jianguo; Bao Gang; Tubuxin

    2008-01-01

    Using improved homogeneous balance method, we obtain complex function form new exact solutions for the (1+1)-dimensional dispersion-less system, and from the exact solutions we derive real function form solution of the field u. Based on this real function form solution, we find some new interesting coherent structures by selecting arbitrary functions appropriately

  7. Exploitation of secondary standard for calibration in units of Dw,1cm and assessment of several HDR brachytherapy planning systems

    International Nuclear Information System (INIS)

    Gabris, F.; Zeman, J.; Valenta, J.; Gabris, F.; Selbach, H.J.

    2012-01-01

    A secondary standard of the BEV, calibrated at the PTB in terms of D w,1c m, was used for calibration of the well-type chamber-based measuring systems used in clinics. In addition to the calibration, we tried to employ it for assessment of treatment planning systems (TPS) used for each particular after-loader. The dose to water at 1 cm distance from the source position was calculated by the TPS, using reference data from the source producer certificate. The values were compared directly with the dose measured at the same distance from the source. The comparison has been carried out for GammaMed Plus and MicroSelectron HDR sources. Differences of secondary standard measurements and TPS calculations were lower than ±5%, which is below the achievable uncertainty of both dose measurement and dose determination by the TPS. Nevertheless, it is higher than generally accepted in the case of external beam radiotherapy. Additional direct measurements in terms of D w,1c m may improve the safety and reliability of patient treatment. (authors)

  8. The role of heme oxygenase-1 in systemic-onset juvenile idiopathic arthritis.

    Science.gov (United States)

    Takahashi, Akitaka; Mori, Masaaki; Naruto, Takuya; Nakajima, Shoko; Miyamae, Takako; Imagawa, Tomoyuki; Yokota, Shumpei

    2009-01-01

    We have determined the serum levels of heme oxygenase-1 (HO-1) in 56 patients with systemic-onset juvenile idiopathic arthritis (s-JIA) and compared these with serum HO-1 levels in healthy controls and patients with other pediatric rheumatic diseases. Serum HO-1 levels were measured by the sandwich enzyme-linked immunosorbent assay. The mean serum HO-1 level in s-JIA patients during the active phase was 123.6 +/- 13.83 ng/ml, which was significantly higher than that in patients with polyarticular juvenile idiopathic arthritis (p-JIA), Kawasaki disease, systemic lupus erythematosus or mixed connective tissue disease (P < 0.0005). The serum levels of HO-1, cytokines and cytokine receptors in patients with s-JIA were also assessed at both the active and inactive phases. The serum HO-1 level in patients with s-JIA in the active phase was found to be significantly greater than that in patients with the disease in the inactive phase (P < 0.0001). An assessment of the relationships between serum HO-1 levels and other laboratory parameters or cytokines in patients with s-JIA did not reveal any strong correlations. These results suggest that the serum level of HO-1 may be a useful marker for the differential diagnosis of s-JIA. Further study will be necessary to elucidate the mechanism of HO-1 production and to clarify the role of HO-1 in the disease process.

  9. New Explicit Solutions of (1 + 1)-Dimensional Variable-Coefficient Broer-Kaup System

    International Nuclear Information System (INIS)

    Yan Zhilian; Zhou Jianping

    2010-01-01

    By using the compatibility method, many explicit solutions of the (1 + 1)-dimensional variable-coefficient Broer-Kaup system are constructed, which include new solutions expressed by error function, Bessel function, exponential function, and Airy function. Some figures of the solutions are given by the symbolic computation system Maple. (general)

  10. FY 93 thermal loading systems study final report: Volume 1. Revision 1

    International Nuclear Information System (INIS)

    Saterlie, S.F.; Thomson, B.H.

    1994-01-01

    The ability to meet the overall performance requirements for the proposed Mined Geology Disposal System at Yucca Mountain, Nevada requires the two major subsystem (natural barriers and engineered barriers) to positively contribute to containment and radionuclide isolation. In addition to the postclosure performance the proposed repository must meet preclosure requirements of safety, retrievability, and operability. Cost and schedule were also considered. The thermal loading strategy chosen may significantly affect both the postclosure and preclosure performance of the proposed repository. Although the current Site Characterization Plan reference case is 57 kilowatts (kW)/acre, other thermal loading strategies (different areal mass loadings) have been proposed which possess both advantages and disadvantages. The objectives of the FY 1993 Thermal Loading Study were to (1) place bounds on the thermal loading which would establish the loading regime that is ''too hot'' and the loading regime that is ''too cold'', to (2) ''grade'' or evaluate the performance, as a function of thermal loading, of the repository to contain high level wastes against performance criteria and to (3) evaluate the performance of the various options with respect to cost, safety, and operability. Additionally, the effort was to (4) identify important uncertainties that need to be resolved by tests and/or analyses in order to complete a performance assessment on the effects of thermal loading. The FY 1993 Thermal Loading Study was conducted from December 1, 1992 to December 30, 1993 and this final report provides the findings of the study. Volume 1 contains the Introduction; Performance requirements; Input and assumptions; Near-field thermal analysis; Far-field thermal analysis; Cost analysis; Other considerations; System analysis; Additional thermal analysis; and Conclusions and recommendations. 71 refs., 54 figs

  11. Petroleum resources assessment 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    This report consists of two articles. (1) Petroleum resources assessment of the Okinawa Trough: The hydrocarbon potential has been evaluated for the Tertiary strata in the northwestern margin of the Okinawa Trough on the basis of the pale-ontological, petrological, geochemical data from two wells (Nikkan 8-9 and JDZ 7-3), and geophysical data. (2) Petroliferous basin analysis in Jinju area (2): Petroleum geological studies such as stratigraphy, sedimentology, petrology and organic geochemistry were carried out in the Gyeongsang Supergroup, Junju area. Based on lithofacies and rock color, the sequence can be divided into seven formations which can be organized into two groups (Sindong Group: Nagdong, Hasandong and Jinju formations in ascending order; Hayang Group: Chilgog, Silla Conglomerate, Haman and Jindong formations). (author). 57 refs.

  12. PL-1 program system for generalized Patterson superpositions. [PL1GEN, SYMPL1, and ALSPL1, in PL/1 for IBM 360/65 computer

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, C.R.; Babich, M.W.; Jacobson, R.A.

    1977-01-01

    A new system of three programs written in PL/1 can calculate symmetry and Patterson superposition maps for triclinic, monoclinic, and orthorhombic space groups as well as any space group reducible to one of these three. These programs are based on a system of FORTRAN programs developed at Ames Laboratory, but are more general and have expanded utility, especially with regard to large unit cells. The program PLIGEN calculates a direct access data set, SYMPL1 calculates a direct access symmetry map, and ALSPL1 calculates a superposition map using one or multiple superpositions. A detailed description of the use of these programs including symbolic program listings is included. 2 tables.

  13. Remedial action and waste disposal project -- 100-DR-1 remedial action readiness assessment report

    International Nuclear Information System (INIS)

    April, J.G.; Ard, J.A.; Corpuz, F.M.; DeMers, S.K.; Donahoe, R.L.; Frank, J.M.; Hobbs, B.J.; Roeck, F.V.

    1997-02-01

    This readiness assessment report presents the results of the project readiness assessment for the 100-DR-1 source sites remediation. The assessment was conducted at the conclusion of a series of project activities that began in August 1996. These activities included confirming the completion of project-specific procedures, training of staff, obtaining support equipment, receipt of subcontractor submittals, and mobilization and construction of site support systems

  14. Technical assessment of Mir-1 life support hardware for the international space station

    Science.gov (United States)

    Mitchell, K. L.; Bagdigian, R. M.; Carrasquillo, R. L.; Carter, D. L.; Franks, G. D.; Holder, D. W., Jr.; Hutchens, C. F.; Ogle, K. Y.; Perry, J. L.; Ray, C. D.

    1994-01-01

    NASA has been progressively learning the design and performance of the Russian life support systems utilized in their Mir space station. In 1992, a plan was implemented to assess the benefits of the Mir-1 life support systems to the Freedom program. Three primary tasks focused on: evaluating the operational Mir-1 support technologies and understanding if specific Russian systems could be directly utilized on the American space station and if Russian technology design information could prove useful in improving the current design of the planned American life support equipment; evaluating the ongoing Russian life support technology development activities to determine areas of potential long-term application to the U.S. space station; and utilizing the expertise of their space station life support systems to evaluate the benefits to the current U.S. space station program which included the integration of the Russian Mir-1 designs with the U.S. designs to support a crew of six.

  15. Assessment Update: Progress, Trends, and Practices in Higher Education. Volume 30, Issue 1, January-February 2018

    Science.gov (United States)

    Hundley, Stephen P., Ed.

    2018-01-01

    This issue of "Assessment Update" presents the following articles: (1) James Madison University: Reflections on Sustained Excellence in Assessment (Keston H. Fulcher and Elizabeth R. H. Sanchez); (2) Editor's Notes: Assessment Excellence Abounds! (Stephen P. Hundley); (3) The Promise of an All-in-One Assessment System for Student…

  16. 10 CFR 960.5-1 - System guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false System guidelines. 960.5-1 Section 960.5-1 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure...

  17. Prototyping the E-ELT M1 local control system communication infrastructure

    Science.gov (United States)

    Argomedo, J.; Kornweibel, N.; Grudzien, T.; Dimmler, M.; Andolfato, L.; Barriga, P.

    2016-08-01

    The primary mirror of the E-ELT is composed of 798 hexagonal segments of about 1.45 meters across. Each segment can be moved in piston and tip-tilt using three position actuators. Inductive edge sensors are used to provide feedback for global reconstruction of the mirror shape. The E-ELT M1 Local Control System will provide a deterministic infrastructure for collecting edge sensor and actuators readings and distribute the new position actuators references while at the same time providing failure detection, isolation and notification, synchronization, monitoring and configuration management. The present paper describes the prototyping activities carried out to verify the feasibility of the E-ELT M1 local control system communication architecture design and assess its performance and potential limitations.

  18. Neutronic analysis of the 1D and 1E banks reflux detection system

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, A.

    1999-12-21

    Two H Canyon neutron monitoring systems for early detection of postulated abnormal reflux conditions in the Second Uranium Cycle 1E and 1D Mixer-Settle Banks have been designed and built. Monte Carlo neutron transport simulations using the general purpose, general geometry, n-particle MCNP code have been performed to model expected response of the monitoring systems to varying conditions.The confirmatory studies documented herein conclude that the 1E and 1D neutron monitoring systems are able to achieve adequate neutron count rates for various neutron source and detector configurations, thereby eliminating excessive integration count time. Neutron count rate sensitivity studies are also performed. Conversely, the transport studies concluded that the neutron count rates are statistically insensitive to nitric acid content in the aqueous region and to the transition region length. These studies conclude that the 1E and 1D neutron monitoring systems are able to predict the postulated reflux conditions for all examined perturbations in the neutron source and detector configurations. In the cases examined, the relative change in the neutron count rates due to postulated transitions from normal {sup 235}U concentration levels to reflux levels remain satisfactory detectable.

  19. Neutronic analysis of the 1D and 1E banks reflux detection system

    International Nuclear Information System (INIS)

    Blanchard, A.

    1999-01-01

    Two H Canyon neutron monitoring systems for early detection of postulated abnormal reflux conditions in the Second Uranium Cycle 1E and 1D Mixer-Settle Banks have been designed and built. Monte Carlo neutron transport simulations using the general purpose, general geometry, n-particle MCNP code have been performed to model expected response of the monitoring systems to varying conditions.The confirmatory studies documented herein conclude that the 1E and 1D neutron monitoring systems are able to achieve adequate neutron count rates for various neutron source and detector configurations, thereby eliminating excessive integration count time. Neutron count rate sensitivity studies are also performed. Conversely, the transport studies concluded that the neutron count rates are statistically insensitive to nitric acid content in the aqueous region and to the transition region length. These studies conclude that the 1E and 1D neutron monitoring systems are able to predict the postulated reflux conditions for all examined perturbations in the neutron source and detector configurations. In the cases examined, the relative change in the neutron count rates due to postulated transitions from normal 235 U concentration levels to reflux levels remain satisfactory detectable

  20. Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics

    International Nuclear Information System (INIS)

    Srivastava, Amit K; Sharma, Manika; Mansuri, Imran; Sharma, Atish; Raval, Tushar; Pradhan, Subrata

    2012-01-01

    Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data

  1. CCL3L1-CCR5 genotype improves the assessment of AIDS Risk in HIV-1-infected individuals.

    Science.gov (United States)

    Kulkarni, Hemant; Agan, Brian K; Marconi, Vincent C; O'Connell, Robert J; Camargo, Jose F; He, Weijing; Delmar, Judith; Phelps, Kenneth R; Crawford, George; Clark, Robert A; Dolan, Matthew J; Ahuja, Sunil K

    2008-09-08

    Whether vexing clinical decision-making dilemmas can be partly addressed by recent advances in genomics is unclear. For example, when to initiate highly active antiretroviral therapy (HAART) during HIV-1 infection remains a clinical dilemma. This decision relies heavily on assessing AIDS risk based on the CD4+ T cell count and plasma viral load. However, the trajectories of these two laboratory markers are influenced, in part, by polymorphisms in CCR5, the major HIV coreceptor, and the gene copy number of CCL3L1, a potent CCR5 ligand and HIV-suppressive chemokine. Therefore, we determined whether accounting for both genetic and laboratory markers provided an improved means of assessing AIDS risk. In a prospective, single-site, ethnically-mixed cohort of 1,132 HIV-positive subjects, we determined the AIDS risk conveyed by the laboratory and genetic markers separately and in combination. Subjects were assigned to a low, moderate or high genetic risk group (GRG) based on variations in CCL3L1 and CCR5. The predictive value of the CCL3L1-CCR5 GRGs, as estimated by likelihood ratios, was equivalent to that of the laboratory markers. GRG status also predicted AIDS development when the laboratory markers conveyed a contrary risk. Additionally, in two separate and large groups of HIV+ subjects from a natural history cohort, the results from additive risk-scoring systems and classification and regression tree (CART) analysis revealed that the laboratory and CCL3L1-CCR5 genetic markers together provided more prognostic information than either marker alone. Furthermore, GRGs independently predicted the time interval from seroconversion to CD4+ cell count thresholds used to guide HAART initiation. The combination of the laboratory and genetic markers captures a broader spectrum of AIDS risk than either marker alone. By tracking a unique aspect of AIDS risk distinct from that captured by the laboratory parameters, CCL3L1-CCR5 genotypes may have utility in HIV clinical management

  2. Independent assessment of the TRAC-BD1/MOD1 computer code at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Wilson, G.E.; Charboneau, B.L.; Dallman, R.J.; Kullberg, C.M.; Wagner, K.C.; Wheatley, P.D.

    1984-01-01

    Under auspices of the United States Nuclear Regulatory Commission, their primary boiling water reactor safety analysis code (TRAC-BWR) is being assessed with simulations of a wide range of experimental data. The FY-1984 assessment activities were associated with the latest version (TRAC-BD1/MOD1) of this code. Typical results of the assessment studies are given. Conclusions formulated from these results are presented. These calculations relate to the overall applicability of the current code to safety analysis, and to future work which would further enhance the code's quality and ease of use

  3. Gas fueling system for SST-1

    International Nuclear Information System (INIS)

    Dhanani, Kalpeshkumar R.; Khan, Ziauddin; Raval, Dilip; Semwal, Pratibha; George, Siju; Paravastu, Yuvakiran; Thankey, Prashant; Khan, Mohammad Shoaib; Pradhan, Subrata

    2015-01-01

    SST-1 Tokamak, the first Indian Steady-state Superconducting experimental device is at present under operation in Institute for Plasma Research. For plasma break down and initiation, the piezoelectric valve based gas feed system is implemented as primary requirement due to its precise control, easy handling, low costs for both construction and maintenance and its flexibility in working gas selection. The main functions of SST-1 gas feed system are to feed the required amount of ultrahigh purity hydrogen gas for specified period into the vessel during plasma operation and ultrahigh helium gas for glow discharge cleaning. In addition to these facilities, the gas feed system is used to feed a mixture gas of hydrogen and helium as well as other gases like nitrogen and Argon during divertor cooling etc. The piezoelectric valves used in SST-1 are remotely driven by a PXI based platform and are calibrated before the plasma operation during each SST-1 plasma operation with precise control. This paper will present the technical development and the results of gas fueling in SST-1. (author)

  4. Operational readiness review phase-1 final report for WRAP-1

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, W., Westinghouse Hanford

    1996-12-27

    This report documents the Operational Readiness Review for WRAP-1 Phase-1 operations. The report includes all criteria, lines of inquiry with resulting Findings and Observations. The review included assessing operational capability of the organization and the computer controlled process and facility systems.

  5. Neuronal human BACE1 knockin induces systemic diabetes in mice.

    Science.gov (United States)

    Plucińska, Kaja; Dekeryte, Ruta; Koss, David; Shearer, Kirsty; Mody, Nimesh; Whitfield, Phillip D; Doherty, Mary K; Mingarelli, Marco; Welch, Andy; Riedel, Gernot; Delibegovic, Mirela; Platt, Bettina

    2016-07-01

    β-Secretase 1 (BACE1) is a key enzyme in Alzheimer's disease pathogenesis that catalyses the amyloidogenic cleavage of amyloid precursor protein (APP). Recently, global Bace1 deletion was shown to protect against diet-induced obesity and diabetes, suggesting that BACE1 is a potential regulator of glucose homeostasis. Here, we investigated whether increased neuronal BACE1 is sufficient to alter systemic glucose metabolism, using a neuron-specific human BACE1 knockin mouse model (PLB4). Glucose homeostasis and adiposity were determined by glucose tolerance tests and EchoMRI, lipid species were measured by quantitative lipidomics, and biochemical and molecular alterations were assessed by western blotting, quantitative PCR and ELISAs. Glucose uptake in the brain and upper body was measured via (18)FDG-PET imaging. Physiological and molecular analyses demonstrated that centrally expressed human BACE1 induced systemic glucose intolerance in mice from 4 months of age onward, alongside a fatty liver phenotype and impaired hepatic glycogen storage. This diabetic phenotype was associated with hypothalamic pathology, i.e. deregulation of the melanocortin system, and advanced endoplasmic reticulum (ER) stress indicated by elevated central C/EBP homologous protein (CHOP) signalling and hyperphosphorylation of its regulator eukaryotic translation initiation factor 2α (eIF2α). In vivo (18)FDG-PET imaging further confirmed brain glucose hypometabolism in these mice; this corresponded with altered neuronal insulin-related signalling, enhanced protein tyrosine phosphatase 1B (PTP1B) and retinol-binding protein 4 (RBP4) levels, along with upregulation of the ribosomal protein and lipid translation machinery. Increased forebrain and plasma lipid accumulation (i.e. ceramides, triacylglycerols, phospholipids) was identified via lipidomics analysis. Our data reveal that neuronal BACE1 is a key regulator of metabolic homeostasis and provide a potential mechanism for the high

  6. Opening a Window on ICME-driven GCR Modulation in the Inner Solar System

    Science.gov (United States)

    Winslow, Reka M.; Schwadron, Nathan A.; Lugaz, Noé; Guo, Jingnan; Joyce, Colin J.; Jordan, Andrew P.; Wilson, Jody K.; Spence, Harlan E.; Lawrence, David J.; Wimmer-Schweingruber, Robert F.; Mays, M. Leila

    2018-04-01

    Interplanetary coronal mass ejections (ICMEs) often cause Forbush decreases (Fds) in the flux of galactic cosmic rays (GCRs). We investigate how a single ICME, launched from the Sun on 2014 February 12, affected GCR fluxes at Mercury, Earth, and Mars. We use GCR observations from MESSENGER at Mercury, ACE/LRO at the Earth/Moon, and MSL at Mars. We find that Fds are steeper and deeper closer to the Sun, and that the magnitude of the magnetic field in the ICME magnetic ejecta as well as the “strength” of the ICME sheath both play a large role in modulating the depth of the Fd. Based on our results, we hypothesize that (1) the Fd size decreases exponentially with heliocentric distance, and (2) that two-step Fds are more common closer to the Sun. Both hypotheses will be directly verifiable by the upcoming Parker Solar Probe and Solar Orbiter missions. This investigation provides the first systematic study of the changes in GCR modulation as a function of distance from the Sun using nearly contemporaneous observations at Mercury, Earth/Moon, and Mars, which will be critical for validating our physical understanding of the modulation process throughout the heliosphere.

  7. Continuous glucose monitoring systems for type 1 diabetes mellitus.

    Science.gov (United States)

    Langendam, Miranda; Luijf, Yoeri M; Hooft, Lotty; Devries, J Hans; Mudde, Aart H; Scholten, Rob J P M

    2012-01-18

    Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that would not have been identified with conventional self-monitoring. Two types of CGM systems can be defined: retrospective systems and real-time systems. Real-time systems continuously provide the actual glucose concentration on a display. Currently, the use of CGM is not common practice and its reimbursement status is a point of debate in many countries. To assess the effects of CGM systems compared to conventional self-monitoring of blood glucose (SMBG) in patients with diabetes mellitus type 1. We searched The Cochrane Library, MEDLINE, EMBASE and CINAHL for the identification of studies. Last search date was June 8, 2011. Randomised controlled trials (RCTs) comparing retrospective or real-time CGM with conventional self-monitoring of blood glucose levels or with another type of CGM system in patients with type 1 diabetes mellitus. Primary outcomes were glycaemic control, e.g. level of glycosylated haemoglobin A1c (HbA1c) and health-related quality of life. Secondary outcomes were adverse events and complications, CGM derived glycaemic control, death and costs. Two authors independently selected the studies, assessed the risk of bias and performed data-extraction. Although there was clinical and methodological heterogeneity between studies an exploratory meta-analysis was performed on those outcomes the authors felt could be pooled without losing clinical merit. The search identified 1366 references. Twenty-two RCTs meeting the inclusion criteria of this review were identified. The results of the meta-analyses (across all age groups) indicate benefit of CGM for patients starting on CGM sensor augmented insulin pump therapy compared to patients using multiple daily injections of

  8. Elevated systemic galectin-1 levels characterize HELLP syndrome.

    Science.gov (United States)

    Schnabel, Annegret; Blois, Sandra M; Meint, Peter; Freitag, Nancy; Ernst, Wolfgang; Barrientos, Gabriela; Conrad, Melanie L; Rose, Matthias; Seelbach-Göbel, Birgit

    2016-04-01

    Galectin-1 (gal-1), a member of a family of conserved β-galactoside-binding proteins, has been shown to exert a key role during gestation. Though gal-1 is expressed at higher levels in the placenta from HELLP patients, it is still poorly understood whether systemic gal-1 levels also differ in HELLP patients. In the present study, we evaluated the systemic expression of gal-1, together with the angiogenic factors, placental growth factor (PlGF) and soluble fms-like tyrosine kinase 1 (sFlt-1) in conjunction with HELLP syndrome severity. Systemic levels of gal-1 and sFlt-1 were elevated in patients with both early- and late-onset HELLP syndrome as compared to healthy controls. In contrast, peripheral PlGF levels were decreased in early- and late-onset HELLP. A positive correlation between systemic gal-1 levels and sFlt-1/PlGF ratios was found in early onset HELLP patients. Our results show that HELLP syndrome is associated with increased circulating levels of gal-1; integrating systemic gal-1 measurements into the diagnostic analyses of pregnant women may provide more effective prediction of HELLP syndrome development. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Boundary Control Systems, Assessment Remedial Investigation. Version 2. 1. Volume 2

    Science.gov (United States)

    1988-12-01

    T25 T25 T25 T25 27002 1 T25 T25 T25 T25 27003 1 T25 T25 T25 T25 27004 1 T25 * * * 27005 1 T25 * T44 * 27006 1 T25 * * * 27007 1 T25 * * * 27008 1 T25...26078 DRY 26081 11700.000 26083 6600.000 26085 3740.000 26088 0.098 26093 0.060 26127 9000.000 26143 4500.000 26145 DRY 27002 46200.000 27003 42300.000...CL y>T AF *-7- CAIL 4-.- - - -j- -. ....... C 1: , .*..401 -ftL T ~ * . . . . .. .. ... ISO ES.I’i C.. ’.~... L S’, ~W~l~ agI~t

  10. Global Combat Support System-Marine Corps Logistics Chain Management Increment 1 (GCSS-MC LCM Inc 1)

    Science.gov (United States)

    2016-03-01

    Global Combat Support System – Marine Corps (GCSS-MC) is a portfolio of systems that supports logistics elements of command and control, joint...future Marine Corps logistics systems modernization . GCSS-MC/LCM Increment 1 Capability Release 1 (hereinafter Release 1.1) is the baseline

  11. Users guide to REGIONAL-1: a regional assessment model

    International Nuclear Information System (INIS)

    Davis, W.E.; Eadie, W.J.; Powell, D.C.

    1979-09-01

    A guide was prepared to allow a user to run the PNL long-range transport model, REGIONAL 1. REGIONAL 1 is a computer model set up to run atmospheric assessments on a regional basis. The model has the capability of being run in three modes for a single time period. The three modes are: (1) no deposition, (2) dry deposition, (3) wet and dry deposition. The guide provides the physical and mathematical basis used in the model for calculating transport, diffusion, and deposition for all three modes. Also the guide includes a program listing with an explanation of the listings and an example in the form of a short-term assessment for 48 hours. The purpose of the example is to allow a person who has past experience with programming and meteorology to operate the assessment model and compare his results with the guide results. This comparison will assure the user that the program is operating in a proper fashion

  12. A GEM Detector System for an Upgrade of the High-eta Muon Endcap Stations GE1/1 + ME1/1 in CMS

    CERN Document Server

    Abbaneo, D; Aspell, P.; Bianco, S.; Hoepfner, K.; Hohlmann, M.; Maggi, M.; De Lentdecker, G.; Safonov, A.; Sharma, A.; Tytgat, M.

    2012-01-01

    Based on the CMS Upgrade R&D Proposal RD10.02, we describe the motivation and main features of the CMS GEM Project for LS2 and propose the addition of a full GE1/12 detector station comprising Gas Electron Multiplier (GEM) chambers to the forward muon system of CMS. The limitations of the currently existing forward muon detector when operating at increasingly high luminosity expected after LS1 are laid out followed by a brief description of the anticipated performance improvements achievable with a GE1/1 station. The second part describes the detector system followed by an overview of electronics and associated services including a discussion of the schedule and cost of the project. Plans for a precursor demonstrator installation in LS1 are presented. This proposal is intended as a concise follow-up of the detailed document CMS-IN-2012-023. If approved, this is to be followed by a detailed Technical Design Report.

  13. The Geo/Geo/1+1 Queueing System with Negative Customers

    OpenAIRE

    Ma, Zhanyou; Guo, Yalin; Wang, Pengcheng; Hou, Yumei

    2013-01-01

    We study a Geo/Geo/1+1 queueing system with geometrical arrivals of both positive and negative customers in which killing strategies considered are removal of customers at the head (RCH) and removal of customers at the end (RCE). Using quasi-birth-death (QBD) process and matrix-geometric solution method, we obtain the stationary distribution of the queue length, the average waiting time of a new arrival customer, and the probabilities of servers in busy or idle period, respectively. Finally, ...

  14. Assessing the Effectiveness of the Early Aberration Reporting System (EARS) for Early Event Detection of the H1N1 (Swine Flu) Virus

    Science.gov (United States)

    2010-09-01

    From Fricker & Hanni , 2010) ..............8 Figure 6. MCHD implementation of the EARS biosurveillance system (After Fricker & Hanni , 2010...11 Figure 8. Confirmed and probable H1N1 case rate by age group from April 15–July 24, 2009 (From Hanni ...United States by age group from April 15 to July 24, 2009 (From Hanni , 2009).......................13 Figure 10. CDC Testing Recommendations for

  15. 1,3-Butadiene: Biomarkers and application to risk assessment

    Czech Academy of Sciences Publication Activity Database

    Swenberg, J. A.; Bordeerat, N. K.; Boysen, G.; Carro, S.; Georgieva, N. I.; Troutman, J. M.; Upton, P. B.; Albertini, R. J.; Vacek, P. M.; Walker, V. E.; Šrám, Radim; Goggin, M.; Tretyakova, N.

    2011-01-01

    Roč. 192, 1-2 (2011), s. 150-154 ISSN 0009-2797 Institutional research plan: CEZ:AV0Z50390512 Keywords : risk assessment * 1,3-butadiene * occupational exposure Subject RIV: DN - Health Impact of the Environment Quality Impact factor: 2.865, year: 2011

  16. Eielson Air Force Base OU-1 baseline risk assessment

    International Nuclear Information System (INIS)

    Jarvis, M.T.; Jarvis, T.T.; Van Houten, N.C.; Lewis, R.E.

    1993-09-01

    This Baseline Risk Assessment report is the second volume in a set of three volumes for operable Unit 1 (OU-1). The companion documents contain the Remedial Investigation and the Feasibility Study. Operable Unit 1 (OU-1) is one of several groups of hazardous waste sites located at Eielson Air Force Base (AFB) near Fairbanks, Alaska. The operable units at Eielson are typically characterized by petroleum, oil, lubricant/solvent contamination, and by the presence of organics floating at the water table. In 1989 and 1990, firms under contract to the Air Force conducted field studies to gather information about the extent of chemical contamination in soil, groundwater, and soil air pore space (soil gas) at the site. This report documents the results of a baseline risk assessment, which uses the 1989 and 1991 site characterization database to quantify the potential human health risk associated with past Base industrial activities in the vicinity of OU-1. Background data collected in 1992 were also used in the preparation of this report

  17. Thermodynamics of (1-alkanol + linear monoether) systems

    International Nuclear Information System (INIS)

    Gonzalez, Juan Antonio; Mozo, Ismael; Garcia de la Fuente, Isaias; Cobos, Jose Carlos; Riesco, Nicolas

    2008-01-01

    Densities, ρ, and speeds of sound, u, of systems formed by 1-heptanol, or 1-octanol, or 1-decanol and dibutylether have been measured at a temperature of (293.15, 298.15, and 303.15) K and atmospheric pressure using a vibrating tube densimeter and sound analyser Anton Paar model DSA-5000. The ρ and u values were used to calculate excess molar volumes, V E , and deviations from the ideal behaviour of the thermal expansion coefficient, Δα p and of the isentropic compressibilities, Δκ S . The available database on molar excess enthalpies, H E , and V E for (1-alkanol + linear monoether) systems was used to investigate interactional and structural effects in such mixtures. The enthalpy of the OH...O bonds is lower for methanol solutions, and for the remainder systems, it is practically independent of the mixture compounds. The V E variation with the chain length of the 1-alkanol points out the existence of structural effects for systems including longer 1-alkanols. The ERAS model is applied to the studied mixtures. ERAS represents quite accurately H E and V E data using parameters which consistently depend on the molecular structure

  18. Assessment of stress tolerance, productivity, and forage quality in T1 transgenic alfalfa co-overexpressing ZxNHX and ZxVP1-1 from Zygophyllum xanthoxylum

    Directory of Open Access Journals (Sweden)

    Peng Kang

    2016-10-01

    Full Text Available Salinization, desertification, and soil nutrient deprivation are threatening the production of alfalfa (Medicago sativa L. in northern China. We have previously generated T0 transgenic alfalfa co-overexpressing Zygophyllum xanthoxylum ZxNHX and ZxVP1-1 genes with enhanced salt and drought tolerance. To further develop this excellent breeding material into the new forage cultivar, stress tolerance, productivity, and forage quality of T1 transgenic alfalfa (GM were assessed in this study. The GM inherited the traits of salt and drought tolerance from T0 generation. Most importantly, co-overexpression of ZxNHX and ZxVP1-1 enhanced the tolerance to Pi deficiency in GM, which was associated with more Pi accumulation in plants. Meanwhile, T1 transgenic alfalfa developed a larger root system with increased root size, root dry weight and root/shoot ratio, which may be one important reason for the improvement of phosphorus nutrition and high biomass accumulation in GM under various conditions. GM also accumulated more crude protein, crude fibre, crude fat, and crude ash than wild-type (WT plants, especially under stress conditions and in the field. More interestingly, the crude fat contents sharply dropped in WT (by 66%-74%, whereas showed no change or decreased less in GM, when subjected to salinity, drought or low-Pi. Our results indicate that T1 transgenic alfalfa co-overexpressing ZxNHX and ZxVP1-1 shows stronger stress tolerance, higher productivity and better forage quality. This study provides a solid foundation for creating the alfalfa cultivars with high yield, good quality and wide adaptability on saline, dry and nutrient-deprived marginal lands of northern China.

  19. Integrated thermal treatment system study -- Phase 2 results. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Feizollahi, F.; Quapp, W.J.

    1996-02-01

    This report presents the second phase of a study on thermal treatment technologies. The study consists of a systematic assessment of nineteen thermal treatment alternatives for the contact-handled mixed low-level waste (MLLW) currently stored in the US Department of Energy complex. The treatment alternatives consist of widely varying technologies for safely destroying the hazardous organic components, reducing the volume, and preparing for final disposal of the MLLW. The alternatives considered in Phase 2 were innovative thermal treatments with nine types of primary processing units. Other variations in the study examined the effect of combustion gas, air pollution control system design, and stabilization technology for the treatment residues. The Phase 1 study examined ten initial thermal treatment alternatives. The Phase 2 systems were evaluated in essentially the same manner as the Phase 1 systems. The alternatives evaluated were: rotary kiln, slagging kiln, plasma furnace, plasma gasification, molten salt oxidation, molten metal waste destruction, steam gasification, Joule-heated vitrification, thermal desorption and mediated electrochemical oxidation, and thermal desorption and supercritical water oxidation. The quantities, and physical and chemical compositions, of the input waste used in the Phase 2 systems differ from those in the Phase 1 systems, which were based on a preliminary waste input database developed at the onset of the Integrated Thermal Treatment System study. The inventory database used in the Phase 2 study incorporates the latest US Department of Energy information. All systems, both primary treatment systems and subsystem inputs, have now been evaluated using the same waste input (2,927 lb/hr). 28 refs., 88 figs., 41 tabs.

  20. Integrated thermal treatment system study -- Phase 2 results. Revision 1

    International Nuclear Information System (INIS)

    Feizollahi, F.; Quapp, W.J.

    1996-02-01

    This report presents the second phase of a study on thermal treatment technologies. The study consists of a systematic assessment of nineteen thermal treatment alternatives for the contact-handled mixed low-level waste (MLLW) currently stored in the US Department of Energy complex. The treatment alternatives consist of widely varying technologies for safely destroying the hazardous organic components, reducing the volume, and preparing for final disposal of the MLLW. The alternatives considered in Phase 2 were innovative thermal treatments with nine types of primary processing units. Other variations in the study examined the effect of combustion gas, air pollution control system design, and stabilization technology for the treatment residues. The Phase 1 study examined ten initial thermal treatment alternatives. The Phase 2 systems were evaluated in essentially the same manner as the Phase 1 systems. The alternatives evaluated were: rotary kiln, slagging kiln, plasma furnace, plasma gasification, molten salt oxidation, molten metal waste destruction, steam gasification, Joule-heated vitrification, thermal desorption and mediated electrochemical oxidation, and thermal desorption and supercritical water oxidation. The quantities, and physical and chemical compositions, of the input waste used in the Phase 2 systems differ from those in the Phase 1 systems, which were based on a preliminary waste input database developed at the onset of the Integrated Thermal Treatment System study. The inventory database used in the Phase 2 study incorporates the latest US Department of Energy information. All systems, both primary treatment systems and subsystem inputs, have now been evaluated using the same waste input (2,927 lb/hr). 28 refs., 88 figs., 41 tabs

  1. Assessing health systems for type 1 diabetes in sub-Saharan Africa: developing a 'Rapid Assessment Protocol for Insulin Access'

    DEFF Research Database (Denmark)

    Beran, David; Yudkin, John S; de Courten, Maximilian

    2006-01-01

    In order to improve the health of people with Type 1 diabetes in developing countries, a clear analysis of the constraints to insulin access and diabetes care is needed. We developed a Rapid Assessment Protocol for Insulin Access, comprising a series of questionnaires as well as a protocol...... for the gathering of other data through site visits, discussions, and document reviews....

  2. 41 CFR 115-1.109 - Numbering in FPMR system.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Numbering in FPMR system. 115-1.109 Section 115-1.109 Public Contracts and Property Management Federal Property Management Regulations System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1...

  3. Ultra Clean 1.1MW High Efficiency Natural Gas Engine Powered System

    Energy Technology Data Exchange (ETDEWEB)

    Zurlo, James; Lueck, Steve

    2011-08-31

    Dresser, Inc. (GE Energy, Waukesha gas engines) will develop, test, demonstrate, and commercialize a 1.1 Megawatt (MW) natural gas fueled combined heat and power reciprocating engine powered package. This package will feature a total efficiency > 75% and ultra low CARB permitting emissions. Our modular design will cover the 1 – 6 MW size range, and this scalable technology can be used in both smaller and larger engine powered CHP packages. To further advance one of the key advantages of reciprocating engines, the engine, generator and CHP package will be optimized for low initial and operating costs. Dresser, Inc. will leverage the knowledge gained in the DOE - ARES program. Dresser, Inc. will work with commercial, regulatory, and government entities to help break down barriers to wider deployment of CHP. The outcome of this project will be a commercially successful 1.1 MW CHP package with high electrical and total efficiency that will significantly reduce emissions compared to the current central power plant paradigm. Principal objectives by phases for Budget Period 1 include: • Phase 1 – market study to determine optimum system performance, target first cost, lifecycle cost, and creation of a detailed product specification. • Phase 2 – Refinement of the Waukesha CHP system design concepts, identification of critical characteristics, initial evaluation of technical solutions, and risk mitigation plans. Background

  4. CERCLA site assessment workbook, Volume 1

    International Nuclear Information System (INIS)

    1994-08-01

    This workbook provides instructions for planning, implementing, and reporting site assessments under CERCLA, commonly referred to as Superfund. Site assessment consists of two information-gathering steps: the remedial preliminary assessment (PA) and the site inspection (SI). The information obtained is then used to estimate, or score, a site's relative risk to public health and the environment. The score is derived via the hazard ranking system (HRS). Although the workbook and its exercises can be adapted to group study, it is designed primarily for use by an individual

  5. "Assessment of human AT1 Binding Affinity of Some Novel 2-alkylthio-1-[4-(N-α-ethoxycarbonyl-nzylaminobenzyl-5-hydroxymethylimidazoles "

    Directory of Open Access Journals (Sweden)

    Setareh Badakhshannoory

    2004-06-01

    Full Text Available Antagonists of various components of the renin-angiotensin system have been the subject of many studies for the control of blood pressure. Compounds with a phenoxyphenylacetic acid moiety that mimic the structure of losartan which is a powerful competitive antagonist of angiotensin receptor, have shown to be effective. In this study, the affinity of some 2-alkylthio-1-[4-(N-α-ethoxycarbonylbenzylaminobenzyl]-5-hydroxymethyl imidazoles for the human AT1 receptor was assessed in a radioligand binding assay. It was found that an alkyl chain of appropriate length would be most suitable if situated on the imidazole ring. Furthermore, variations of the lower phenyl rings demonstrated that introduction of a methyl group in this position will account for the most desired effect.

  6. Carbon isotope fractionation of 1,1,1-trichloroethane during base-catalyzed persulfate treatment

    International Nuclear Information System (INIS)

    Marchesi, Massimo; Thomson, Neil R.; Aravena, Ramon; Sra, Kanwartej S.; Otero, Neus; Soler, Albert

    2013-01-01

    Highlights: • Treatability and C fractionation of 1,1,1-TCA by base-catalyzed S 2 O 8 2− was studied. • The rate of degradation of 1,1,1-TCA increased with a higher OH − :S 2 O 8 2− ratio. •Base-catalyzed S 2 O 8 2− can potentially treat recalcitrant compound like 1,1,1-TCA. • An enrichment factor of −7.0‰ independent of the OH − :S 2 O 8 2− ratio was obtained. • Carbon isotope can potentially be used to estimate the ISCO treatment efficacy. -- Abstract: The extent of carbon isotope fractionation during degradation of 1,1,1-trichloroethane (1,1,1-TCA) by a base-catalyzed persulfate (S 2 O 8 2− ) treatment system was investigated. Significant destruction of 1,1,1-TCA was observed at a pH of ∼12. An increase in the NaOH:S 2 O 8 2− molar ratio from 0.2:1 to 8:1 enhanced the reaction rate of 1,1,1-TCA by a factor of ∼5 to yield complete (>99.9%) destruction. An average carbon isotope enrichment fractionation factor which was independent of the NaOH:S 2 O 8 2− molar ratio of −7.0 ± 0.2‰ was obtained. This significant carbon isotope fractionation and the lack of dependence on changes in the NaOH:S 2 O 8 2− molar ratio demonstrates that carbon isotope analysis can potentially be used in situ as a performance assessment tool to estimate the degradation effectiveness of 1,1,1-TCA by a base-catalyzed persulfate system

  7. Comparison of RECIST version 1.0 and 1.1 in assessment of tumor response by computed tomography in advanced gastric cancer.

    Science.gov (United States)

    Jang, Gil-Su; Kim, Min-Jeong; Ha, Hong-Il; Kim, Jung Han; Kim, Hyeong Su; Ju, Sung Bae; Zang, Dae Young

    2013-12-01

    Response Evaluation Criteria in Solid Tumors (RECIST) guideline version 1.0 (RECIST 1.0) was proposed as a new guideline for evaluating tumor response and has been widely accepted as a standardized measure. With a number of issues being raised on RECIST 1.0, however, a revised RECIST guideline version 1.1 (RECIST 1.1) was proposed by the RECIST Working Group in 2009. This study was conducted to compare CT tumor response based on RECIST 1.1 vs. RECIST 1.0 in patients with advanced gastric cancer (AGC). We reviewed 61 AGC patients with measurable diseases by RECIST 1.0 who were enrolled in other clinical trials between 2008 and 2010. These patients were retrospectively re-analyzed to determine the concordance between the two response criteria using the κ statistic. The number and sum of tumor diameters of the target lesions by RECIST 1.1 were significantly lower than those by RECIST 1.0 (P<0.0001). However, there was excellent agreement in tumor response between RECIST 1.1 and RECIST 1.0 (κ=0.844). The overall response rates (ORRs) according to RECIST 1.0 and RECIST 1.1 were 32.7% (20/61) and 34.5% (20/58), respectively. One patient with partial response (PR) based on RECIST 1.0 was reclassified as stable disease (SD) by RECIST 1.1. Of two patients with SD by RECIST 1.0, one was downgraded to progressive disease and the other was upgraded to PR by RECIST 1.1. RECIST 1.1 provided almost perfect agreement with RECIST 1.0 in the CT assessment of tumor response of AGC.

  8. A General Method for Assessing the Origin of Interstellar Small Bodies: The Case of 1I/2017 U1 (‘Oumuamua)

    Science.gov (United States)

    Zuluaga, Jorge I.; Sánchez-Hernández, Oscar; Sucerquia, Mario; Ferrín, Ignacio

    2018-06-01

    With the advent of more and deeper sky surveys, the discovery of interstellar small objects entering into the solar system has been finally possible. In 2017 October 19, using observations of the Pan-STARRS survey, a fast moving object, now officially named 1I/2017 U1 (‘Oumuamua), was discovered in a heliocentric unbound trajectory, suggesting an interstellar origin. Assessing the provenance of interstellar small objects is key for understanding their distribution, spatial density, and the processes responsible for their ejection from planetary systems. However, their peculiar trajectories place a limit on the number of observations available to determine a precise orbit. As a result, when its position is propagated ∼105–106 years backward in time, small errors in orbital elements become large uncertainties in position in the interstellar space. In this paper we present a general method for assigning probabilities to nearby stars of being the parent system of an observed interstellar object. We describe the method in detail and apply it for assessing the origin of ‘Oumuamua. A preliminary list of potential progenitors and their corresponding probabilities is provided. In the future, when further information about the object and/or the nearby stars be refined, the probabilities computed with our method can be updated. We provide all the data and codes we developed for this purpose in the form of an open source C/C++/Python package, iWander, which is publicly available at http://github.com/seap-udea/iWander.

  9. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5-Triazine (RDX) (Public Comment Draft)

    Science.gov (United States)

    EPA is developing an Integrated Risk Information System (IRIS) assessment of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and has released the draft assessment for public comment. When final, the assessment will appear on the IRIS database.

  10. Standing, Periodic and Solitary Waves in (1 + 1)-Dimensional Caudry-Dodd-Gibbon-Sawada-Kortera System

    International Nuclear Information System (INIS)

    Zheng Chunlong; Qiang Jiye; Wang Shaohua

    2010-01-01

    In the paper, the variable separation approach, homoclinic test technique and bilinear method are successfully extended to a (1 + 1)-dimensional Caudry-Dodd-Gibbon-Sawada-Kortera (CDGSK) system, respectively. Based on the derived exact solutions, some significant types of localized excitations such as standing waves, periodic waves, solitary waves are simultaneously derived from the (1 + 1)-dimensional Caudry-Dodd-Gibbon-Sawada-Kortera system by entrancing appropriate parameters. (general)

  11. 41 CFR 101-1.109 - Numbering in FPMR System.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Numbering in FPMR System. 101-1.109 Section 101-1.109 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101...

  12. 41 CFR 101-1.105 - Authority for FPMR System.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Authority for FPMR System. 101-1.105 Section 101-1.105 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101...

  13. EFFICACY OF MODIFIED MULTICOMPONENT SYSTEM1C: ENTERPRISE” IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    A. A. Modestov

    2016-01-01

    Full Text Available Background: Automated accounting and controlling system1C: Enterprise” is widely used in Russia for optimizing the system of controlling materials and technical resources. Medical organizations modify them in line with their primary activity objectives. For many years, the Scientific Center of Children’s Health has been successfully using a 1C-based medical information system including electronic patient records. An innovative product — an additional block for accounting equipment and supplies (E&S — was developed in 2014.Objective: Our aim was to conduct a sociological analysis of results of the first stage of modified multicomponent system1C: Enterprise” implementation.Methods: The cross-sectional full-design study was conducted from October 2014 to June 2015. We used the analytical method, the opinion poll method and the expert method. We developed a special questionnaire for the purposes of the poll. We assessed opinions of clinic employees, departments and services indirectly or directly working with the system.Results: The study results demonstrate that multifunctional and adapted towards peculiarities of activities of the Scientific Center of Children’s Health system1C: Enterprise” provides more efficient control over the use of drugs, expendables and other E&S in patient terms. It also allows simplifying and automatizing operation of the E&S accounting system by the employees and generating financial statements for a given period in terms of patient/department/clinic. At the same time, the poll revealed problematic technical, informational and motivational aspects. This is confirmed by the degree of involvement/personal interest of employees in the end result, as well as by the priorities of motivation for quality work.Conclusion: Analysis of attitude of accountable persons to the modification of accounting policy of the Scientific Center of Children’s Health served as the basis for developing measures of

  14. Study of infrared emission spectroscopy for the B1Δg–A1Πu and B′1Σg+–A1Πu systems of C2

    International Nuclear Information System (INIS)

    Chen, Wang; Kawaguchi, Kentarou; Tang, Jian; Bernath, Peter F.

    2016-01-01

    Thirteen bands for the B 1 Δ g –A 1 Π u system and eleven bands for the B ′1 Σ g + –A 1 Π u system of C 2 were identified in the Fourier transform infrared emission spectra of hydrocarbon discharges. The B ′1 Σ g + v = 4 and the B 1 Δ g v = 6, 7, and 8 vibrational levels involved in nine bands were studied for the first time. A direct global analysis with Dunham parameters was carried out satisfactorily for the B 1 Δ g –A 1 Π u system except for a small perturbation in the B 1 Δ g v = 6 level. The calculated rovibrational term energies up to B 1 Δ g v = 12 showed that the level crossing between the B 1 Δ g and d 3 Π g states is responsible for many of the prominent perturbations in the Swan system observed previously. Nineteen forbidden transitions of the B 1 Δ g –a 3 Π u transition were identified and the off-diagonal spin-orbit interaction constant A dB between d 3 Π g and B 1 Δ g was derived as 8.3(1) cm −1 . For the B ′1 Σ g + –A 1 Π u system, only individual band analyses for each vibrational level in the B′ 1 Σ g + state could be done satisfactorily and Dunham parameters obtained from these effective parameters showed that the anharmonic vibrational constant ω e x e is anomalously small (nearly zero). Inspection of the RKR (Rydberg-Klein-Rees) potential curves for the B ′1 Σ g + and X 1 Σ g + states revealed that an avoided crossing or nearly avoided crossing may occur around 30 000 cm −1 , which is responsible for the anomalous molecular constants in these two states

  15. RELAP5-3D Developmental Assessment: Comparison of Versions 4.2.1i and 4.1.3i

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-06-01

    Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.2.1i and 4.1.3i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

  16. Printing system perceptual-based gloss and gloss uniformity standard (INCITS W1.1)

    Science.gov (United States)

    Ng, Yee S.; Cui, Luke C.; Kuo, Chung-Hui; Maggard, Eric; Mashtare, Dale; Morris, Peter; Viola, Michael

    2003-12-01

    To address the standarization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standarization committee for office equipment charactered the W1.1 project with the responsibiltiy of drafting a proposal for an international standard for the evaluation of printed image quality. One of the W1.1 task teams is charactered to address the issue of 'Gloss and Gloss Uniformity". This paper summarizes the current status and technical progress of this ad hoc team in 2003.

  17. Stereospecific transport of Tyr-MIF-1 across the blood-brain barrier by peptide transport system-1

    Energy Technology Data Exchange (ETDEWEB)

    Banks, W.A.; Kastin, A.J.; Michals, E.A.; Barrera, C.M. (Veterans Affairs Medical Center, New Orleans, LA (USA))

    1990-10-01

    Previous studies have suggested that peptide transport system-1 (PTS-1), the saturable system that transports Tyr-MIF-1, the enkephalins, and related peptides out of the central nervous system (CNS), exhibits stereospecificity. In the present studies, we showed that {sup 125}I-L-Tyr-MIF-1, but not {sup 131}I-D-Tyr-MIF-1, was cleared from the CNS more rapidly than could be accounted for by nonspecific mechanisms. Such clearance was inhibited by a 1.0 nmol dose of L-Tyr-MIF-1, but not by D-Tyr-MIF-1. Neither L- nor D-Tyr-MIF-1 altered the much lower clearance of I-D-Tyr-MIF-1 from the brain. Radioactivity recovered from the vascular space after the injection of {sup 125}I-Tyr-MIF-1 into the lateral ventricle of the brain eluted by HPLC primarily as intact peptide, demonstrating that most of the Tyr-MIF-1 was not degraded during transport. By contrast, the nonsaturable unidirectional influx of Tyr-MIF-1 into the CNS did not distinguish between the isomers. These studies confirm and extend the observations that Tyr-MIF-1 is transported out of the CNS by a saturable, stereospecific transport system as an intact peptide while the influx into the CNS is by a nonsaturable mechanism that does not distinguish between the isomers.

  18. Carbon isotope fractionation of 1,1,1-trichloroethane during base-catalyzed persulfate treatment

    Energy Technology Data Exchange (ETDEWEB)

    Marchesi, Massimo, E-mail: m2marche@uwaterloo.ca [Department of Civil and Environmental Engineering, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); Department of Earth and Environmental Sciences, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); Thomson, Neil R. [Department of Civil and Environmental Engineering, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); Aravena, Ramon [Department of Earth and Environmental Sciences, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); Sra, Kanwartej S. [Department of Civil and Environmental Engineering, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1 (Canada); Golder Associates Inc, Toronto, Ontario, Canada L5N 5Z7 (Canada); Otero, Neus; Soler, Albert [Departament de Cristal.lographia, Mineralogia i Diposits Minerals, Facultat de Geologia, Universitat de Barcelona, Barcelona, Spain 08028 (Spain)

    2013-09-15

    Highlights: • Treatability and C fractionation of 1,1,1-TCA by base-catalyzed S{sub 2}O{sub 8}{sup 2−} was studied. • The rate of degradation of 1,1,1-TCA increased with a higher OH{sup −}:S{sub 2}O{sub 8}{sup 2−} ratio. •Base-catalyzed S{sub 2}O{sub 8}{sup 2−} can potentially treat recalcitrant compound like 1,1,1-TCA. • An enrichment factor of −7.0‰ independent of the OH{sup −}:S{sub 2}O{sub 8}{sup 2−} ratio was obtained. • Carbon isotope can potentially be used to estimate the ISCO treatment efficacy. -- Abstract: The extent of carbon isotope fractionation during degradation of 1,1,1-trichloroethane (1,1,1-TCA) by a base-catalyzed persulfate (S{sub 2}O{sub 8}{sup 2−}) treatment system was investigated. Significant destruction of 1,1,1-TCA was observed at a pH of ∼12. An increase in the NaOH:S{sub 2}O{sub 8}{sup 2−} molar ratio from 0.2:1 to 8:1 enhanced the reaction rate of 1,1,1-TCA by a factor of ∼5 to yield complete (>99.9%) destruction. An average carbon isotope enrichment fractionation factor which was independent of the NaOH:S{sub 2}O{sub 8}{sup 2−} molar ratio of −7.0 ± 0.2‰ was obtained. This significant carbon isotope fractionation and the lack of dependence on changes in the NaOH:S{sub 2}O{sub 8}{sup 2−} molar ratio demonstrates that carbon isotope analysis can potentially be used in situ as a performance assessment tool to estimate the degradation effectiveness of 1,1,1-TCA by a base-catalyzed persulfate system.

  19. Experimental applications for the MARK-1 and MARK-1A pulsed ionizing radiation detection systems. Volume 3

    International Nuclear Information System (INIS)

    Harker, Y.D.; Lawrence, R.S.; Yoon, W.Y.; Lones, J.L.

    1993-12-01

    This report is the third volume in a three volume set describing the MARK series of pulsed ionizing radiation detection systems. This volume describes the MARK-1A detection system, compares it with the MARK-1 system, and describes the experimental testing of the detection systems. Volume 1 of this set presents the technical specifications for the MARK-1 detection system. Volume 2 is an operations manual specifically for the MARK-1 system, but it generally applies to the MARK-1A system as well. These detection systems operate remotely and detect photon radiation from a single or a multiple pulsed source. They contain multiple detector (eight in the MARK-1 and ten in the MARK-1A) for determination of does and incident photon effective energy. The multiple detector arrangement, having different detector sizes and shield thicknesses, provides the capability of determining the effective photon energy of the radiation spectrum. Dose measurements using these units are consistent with TLD measurements. The detection range is from 3 nanorads to 90 microrads per source burst; the response is linear over that range. Three units were built and are ready for field deployment

  20. Psacoin level 1B intercomparison: An International code intercomparison exercise on a hypothetical safety assessment case study for radioactive waste disposal systems

    International Nuclear Information System (INIS)

    Klos, R.A.; Sinclair, J.E.; Torres, C.; Bergstroem, U.; Galson, D.A.

    1993-06-01

    This report focuses on the biosphere modelling aspects of the assessment of the radiological impact of the disposal of radioactive waste in greater detail. Seven exposure pathways are modelled: drinking water, freshwater fish, meat, milk and grain consumption as well as external gamma irradiation and contaminated dust inhalation. The accumulation of radionuclides, released in groundwaters, in the upper soil is also modelled. The objectives of this Level 1b exercise can be summarized as follows: 1 to gain experience in the application of probabilistic systems assessment methodology to transport and radiological exposure sub-models for the biosphere and hence to methods of estimating the total risk to individuals or groups of individuals; 2 to contribute to the verification of biosphere transport and exposure sub-models; 3 to investigate the effects of parameter uncertainty in the biosphere transport and exposure sub-models on the estimate of mean dose to individuals exposed via several exposure pathways

  1. Gas Fuelling System for SST-1Tokamak

    Science.gov (United States)

    Dhanani, Kalpesh; Raval, D. C.; Khan, Ziauddin; Semwal, Pratibha; George, Siju; Paravastu, Yuvakiran; Thankey, Prashant; Khan, M. S.; Pradhan, Subrata

    2017-04-01

    SST-1 Tokamak, the first Indian Steady-state Superconducting experimental device is at present under operation in the Institute for Plasma Research. For plasma break down & initiation, piezoelectric valve based gas feed system is implemented as a primary requirement due to its precise control, easy handling, low construction and maintenance cost and its flexibility in the selection of the working gas. Hydrogen gas feeding with piezoelectric valve is used in the SST-1 plasma experiments. The piezoelectric valves used in SST-1 are remotely driven by a PXI based platform and are calibrated before each SST-1 plasma operation with precise control. This paper will present the technical development and the results of the gas fuelling system of SST-1.

  2. User's guide for PRISM (Plant Risk Status Information Management System) Arkansas Nuclear One-Unit 1: Volume 1, Program for inspectors

    International Nuclear Information System (INIS)

    Campbell, D.J.; Guthrie, V.H.; Kirchner, J.R.; Kirkman, J.Q.; Paula, H.M.; Ellison, B.C.; Dycus, F.M.; Farquharson, J.A.; Flanagan, G.F.

    1988-03-01

    This user's guide is a two-volume document designed to teach NRC inspectors and NRC regulators how to access probabilistic risk assessment information from the two Plant Risk Status Information Management System (PRISIM) programs developed for Arkansas Nuclear One -- Unit One (ANO-1). This document, Volume 1, describes how the PRA information available in Version 1.0 of PRISIM is useful for planning inspections. Using PRISIM, inspectors can quickly access PRA information and use that information to update risk analysis results, reflecting a plant's status at any particular time. Both volumes are stand-alone documents, and each volume presents several sample computer sessions designed to lead the user through a variety of PRISIM applications used to obtain PRA-related information for monitoring and controlling plant risk

  3. 2005 Tri-Service Infrastructure Systems Conference and Exhibition. Volume 1, Track 1

    Science.gov (United States)

    2005-08-04

    Alan Tool Sediment Impact Assessment Model (SIAM), by David S. Biedenharn and Meg Jonas Mississippi River Sedimentation Study, by Basil Arthur Sediment...Questionnaire Client Report Reports Criteria/Lesson Learned Project Details PRO JEC TS DAT ABA SE 9 eProjects 1. Business Line CIBL Program ANY MILCON 2

  4. Shift of semimetal-semiconductor bond direction on “0 1 1” to “1 1 1” Bismuth quazi-two-dimension system

    Science.gov (United States)

    Yazdani, Ahmad; Hamreh, Sajad

    2018-03-01

    The electronic structure of the nanocrystallines and quasi-two-dimensional systems strongly impressed by the thermodynamic- behavior mainly due to excess of hidden surface free energy. Therefore, the stability of crystalline structure’s change could be related to band-offset of bond rupturing of atomic displacements. whereas for the electronic-structure of "Bi" it seams the competition of L.S and bond exchange should be effectively dominated. Besides all of the characters behave spatial like strong sensitive oxidation here it is supposed that strong correlated electronic structure in the absence of oxygen is resulted on direction of redistribution of surface chemical bond formation before any reconstructive structure. Where • The metallic direction of electronic structure “0 1 1” is changed to “1 1 1” semiconductor direction. • the effect of L.S is more evident on the local density of state while it is not observable around the fermi level. • Strong effect of spin-orbit interaction on splitting of the valance to nearly conduction band around the fermi level is more evident.

  5. Peer Review Plan for OPPT Work Plan Risk Assessment of 1 - Bromopropane (“1 - BP”)

    Science.gov (United States)

    This document outlines the peer review plan for a risk assessment which addresses occupational uses of 1-BP in dry-cleaning and foam gluing operations, consumer uses in aerosol solvent cleaners and spray adhesives, and its effects on human health.

  6. Endothelin-1 in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    C. Pizzorni

    2011-09-01

    Full Text Available We evaluated endothelin-1 (ET-1 plasma levels in patients affected by primary Raynaud’s phenomenon (PRP, as well as in patients with systemic sclerosis (SSc and secondary Raynaud’s phenomenon (SRP. Furthermore, ET-1 levels were investigated in SSc patients with different patterns of peripheral microvascular damage, as evaluated by nailfold videocapillaroscopy (NVC. Methods: 23 PRP patients, 67 SSc patients according to ACR criteria, and 23 healthy subjects were enrolled. SSc microvascular involvement was classified in three different patterns (Early, Active, and Late by NVC, as previously described. Results: ET-1 was found significantly higher in both PRP and SRP, when compared with controls (median ±IQR: 3.3±2.8, 2.7±2.2, 2.0±2.2, respectively (p=0.05. No statistically significant difference of ET-1 levels was observed between PRP and SRP patients. ET-1 was found higher in patients with Late NVC pattern, when compared with both Active and Early NVC patterns (median±IQR: 3.4±2.5, 2.4±2.2, 2.5±2.1, respectively, but without statistical significance. Patients with Late NVC pattern showed significantly higher ET-1 plasma levels than controls (p=0.03. No correlation was found between ET-1 levels and disease duration in both groups, as well as between ET-1 levels and age of patients. Conclusions: These data support previous studies, reporting increased ET-1 plasma levels in both PRP and SRP patients. Interestingly, patients with the Late NVC pattern of microangiopathy showed higher ET-1 plasma levels than controls. The high levels of ET-1 detected in the Late NVC pattern of microangiopathy might be related to the larger fibrotic involvement typical of the advanced stages of disease.

  7. Study of interfacial phenomena of organo-chlorinated steam adsorption on a microporous adsorbent. Case of tri chloro-1,1,1 ethane on activated charcoal

    International Nuclear Information System (INIS)

    Escallon, S.

    1991-06-01

    This study involves the construction and the perfecting of a test system for evaluating the service life of organic vapor cartridges versus 1,1,1 -trichloroethane. Thermogravimetric measurements were carried on in order to suggest a field method to reactive these cartridges, using hot air flow system. Assessment of adsorption rate during experiment is measured with a new electrical method. (author)

  8. Lake Whitney Comprehensive Water Quality Assessment, Phase 1B- Physical and Biological Assessment (USDOE)

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Robert D; Byars, Bruce W

    2009-11-24

    Baylor University Center for Reservoir and Aquatic Systems Research (CRASR) has conducted a phased, comprehensive evaluation of Lake Whitney to determine its suitability for use as a regional water supply reservoir. The area along the Interstate 35 corridor between Dallas / Fort Worth Metroplex and the Waco / Temple Centroplex represents one of the fastest growth areas in the State of Texas and reliable water supplies are critical to sustainable growth. Lake Whitney is situated midway between these two metropolitan areas. Currently, the City of Whitney as well as all of Bosque and Hill counties obtain their potable water from the Trinity Sands aquifer. Additionally, parts of the adjoining McLennan and Burleson counties utilize the Trinity sands aquifer system as a supplement to their surface water supplies. Population growth coupled with increasing demands on this aquifer system in both the Metroplex and Centroplex have resulted in a rapid depletion of groundwater in these rural areas. The Lake Whitney reservoir represents both a potentially local and regional solution for an area experiencing high levels of growth. Because of the large scope of this project as well as the local, regional and national implications, we have designed a multifaceted approach that will lead to the solution of numerous issues related to the feasibility of using Lake Whitney as a water resource to the region. Phase IA (USEPA, QAPP Study Elements 1-4) of this research focused on the physical limnology of the reservoir (bathymetry and fine scale salinity determination) and develops hydrodynamic watershed and reservoir models to evaluate how salinity would be expected to change with varying hydrologic and climatic factors. To this end, we implemented a basic water quality modeling program in collaboration with the Texas Parks and Wildlife Department and the Texas Commission on Environmental Quality to add to the developing long-term database on Lake Whitney. Finally, we conducted an initial

  9. Data acquisition system in TPE-1RM15

    International Nuclear Information System (INIS)

    Yagi, Yasuyuki; Yahagi, Eiichi; Hirano, Yoichi; Shimada, Toshio; Hirota, Isao; Maejima, Yoshiki

    1991-01-01

    The data acquisition system for TPE-1RM15 reversed field pinch machine had been developed and has recently been completed. Thd data to be acquired consist of many channels of time series data which come from plasma diagnostics. The newly developed data acquisition system uses CAMAC (Computer Automated Measurement And Control) system as a front end data acquisition system and micro-VAX II for control, file management and analyses. Special computer programs, DAQR/D, have been developed for data acquisition routine. Experimental setting and process controlling items are managed by a parameter database in a shared common region and every task can easily refer to it. The acquired data are stored into a mass storage system (total of 1.3GBytes plus a magnetic tape system) including an optical disk system, which can save storage space and allow quick reference. At present, the CAMAC system has 88 (1MHz sampling) and 64(5kHz sampling) channels corresponding to 1.6 MBytes per shot. The data acquisition system can finish one routine within 5 minutes with 1.6MBytes data depending on the amount of graphic outputs. Hardwares and softwares of the system are specified so that the system can be easily expanded. The computer is connected to the AIST Ethernet and the system can be remotely accessed and the acquired data can be transferred to the mainframes on the network. Details about specifications and performance of the system are given in this report. (author)

  10. Expression of PD-1 and PD-L1 in poorly differentiated neuroendocrine carcinomas of the digestive system: a potential target for anti-PD-1/PD-L1 therapy.

    Science.gov (United States)

    Roberts, Jordan A; Gonzalez, Raul S; Das, Satya; Berlin, Jordan; Shi, Chanjuan

    2017-12-01

    Poorly differentiated neuroendocrine carcinoma of the digestive system has a dismal prognosis with limited treatment options. This study aimed to investigate expression of the PD-1/PD-L1 pathway in these tumors. Thirty-seven patients with a poorly differentiated neuroendocrine carcinoma of the digestive system were identified. Their electronic medical records, pathology reports, and pathology slides were reviewed for demographics, clinical history, and pathologic features. Tumor sections were immunohistochemically labeled for PD-1 and PD-L1, and expression of PD-1 and PD-L1 on tumor and tumor-associated immune cells was analyzed and compared between small cell and large cell neuroendocrine carcinomas. The mean age of patients was 61 years old with 18 men and 19 women. The colorectum (n=20) was the most common primary site; other primary sites included the pancreaticobiliary system, esophagus, stomach, duodenum, and ampulla. Expression of PD-1 was detected on tumor cells (n=6, 16%) as well as on tumor-associated immune cells (n=23, 63%). The 6 cases with PD-1 expression on tumor cells also had the expression on immune cells. Expression of PD-L1 was visualized on tumor cells in 5 cases (14%) and on tumor-associated immune cells in 10 cases (27%). There was no difference in PD-1 and PD-L1 expression between small cell and large cell neuroendocrine carcinomas. In conclusion, PD-1/PD-L1 expression is a frequent occurrence in poorly differentiated neuroendocrine carcinomas of the digestive system. Checkpoint blockade targeting the PD-1/PD-L1 pathway may have a potential role in treating patients with this disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Development methodology of the novel Endoscopic stone treatment step 1 (EST s1) training/assessment curriculum.

    Science.gov (United States)

    Veneziano, Domenico; Ahmed, Kamran; Van Cleynenbreugel, Ben S E P; Gözen, Ali Serdar; Palou, Joan; Sarica, Kemal; Liatsikos, Evangelos N; Sanguedolce, Francesco; Honeck, Patrick; Alvarez-Maestro, Mario; Papatsoris, Athanasios; Kallidonis, Panagiotis; Greco, Francesco; Breda, Alberto; Somani, Bhaskar

    2017-07-10

    Background Simulation based technical-skill assessment is a core topic of debate, especially in high-risk environments. After the introduction of the E-BLUS exam for basic laparoscopy, no more technical training/assessment urological protocols have been developed in Europe. Objective We describe the methodology used in the development of the novel Endoscopic Stone Treatment step 1 (EST s1) assessment curriculum. Materials and Methods The "full life cycle curriculum development" template was followed for curriculum development. A CTA was run to define the most important steps and details of RIRS, in accordance with EAU Urolithiasis guidelines. Training tasks were created between April 2015 and September 2015. Tasks and metrics were further analyzed by a consensus meeting with the EULIS board in February 2016. A review, aimed to study available simulators and their accordance with task requirements, was subsequently run in London on March 2016. After initial feedback and further tests, content validity of this protocol was achieved during EUREP 2016. Results The EST s1 curriculum development, took 23 months. 72 participants tested the 5 preliminary tasks during EUREP 2015, with sessions of 45 minutes each. Likert-scale questionnaires were filled-out to score the quality of training. The protocol was modified accordingly and 25 participants tested the 4 tasks during the hands-on training sessions of the ESUT 2016 congress. 134 participants finally participated in the validation study in EUREP 2016. During the same event 10 experts confirmed content validity by filling-out a Likert-scale questionnaire. Conclusion We described a reliable and replicable methodology that can be followed to develop training/assessment protocols for surgical procedures. The expert consensus meetings, strict adherence to guidelines and updated literature search towards an Endourology curriculum allowed correct training and assessment protocol development. It is the first step towards

  12. Risk assessment of fumonisin B1 in the Netherlands

    OpenAIRE

    Bakker MI; Speijers GJA; Paulsch WE; van Egmond HP; SIR; ARO

    2004-01-01

    Fumonisin B1 is a mycotoxin that can be produced by certain Fusarium species. The toxin is found, in particular, in maize and maize products, but occurrence in boeth wheat and wheat products, and rice and rice products, has also been reported. The intake of fumonisin B1 by the population in the Netherlands was estimated in an exposure assessment using data on concentrations of fumonisin B1 in different food products combined with the consumption rate of these products. From the (limited) resu...

  13. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  14. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  15. Development and testing of multigroup library with correction of self-shielding effects in fusion-fission hybrid reactor

    International Nuclear Information System (INIS)

    Zou Jun; He Zhaozhong; Zeng Qin; Qiu Yuefeng; Wang Minghuang

    2010-01-01

    A multigroup library HENDL2.1/SS (Hybrid Evaluated Nuclear Data Library/Self-Shielding) based on ENDF/B-VII.0 evaluate data has been generated using Bondarenko and flux calculator method for the correction of self-shielding effect of neutronics analyses. To validate the reliability of the multigroup library HENDL2.1/SS, transport calculations for fusion-fission hybrid system FDS-I were performed in this paper. It was verified that the calculations with the HENDL2.1/SS gave almost the same results with MCNP calculations and were better than calculations with the HENDL2.0/MG which is another multigroup library without self-shielding correction. The test results also showed that neglecting resonance self-shielding caused underestimation of the K eff , neutron fluxes and waste transmutation ratios in the multigroup calculations of FDS-I.

  16. Interpretation of vadose zone monitoring system data near Engineered Trench 1

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Whiteside, T. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-12

    The E-Area Vadose Zone Monitoring System (VZMS) includes lysimeter sampling points at many locations alongside and angling beneath the Engineered Trench #1 (ET1) disposal unit footprint. The sampling points for ET1 were selected for this study because collectively they showed consistently higher tritium (H-3) concentrations than lysimeters associated with other trench units. The VZMS tritium dataset for ET1 from 2001 through 2015 comprises concentrations at or near background levels at approximately half of locations through time, concentrations up to about 600 pCi/mL at a few locations, and concentrations at two locations that have exceeded 1000 pCi/mL. The highest three values through 2015 were 6472 pCi/mL in 2014 and 4533 pCi/mL in 2013 at location VL-17, and 3152 pCi/mL in 2007 at location VL-15. As a point of reference, the drinking water standard for tritium and a DOE Order 435.1 performance objective in the saturated zone at the distant 100-meter facility perimeter is 20 pCi/mL. The purpose of this study is to assess whether these elevated concentrations are indicative of a general trend that could challenge 2008 E-Area Performance Assessment (PA) conclusions, or are isolated perturbations that when considered in the context of an entire disposal unit would support PA conclusions.

  17. Enhanced interplanetary panspermia in the TRAPPIST-1 system.

    Science.gov (United States)

    Lingam, Manasvi; Loeb, Abraham

    2017-06-27

    We present a simple model for estimating the probability of interplanetary panspermia in the recently discovered system of seven planets orbiting the ultracool dwarf star TRAPPIST-1 and find that panspermia is potentially orders of magnitude more likely to occur in the TRAPPIST-1 system compared with the Earth-to-Mars case. As a consequence, we argue that the probability of abiogenesis is enhanced on the TRAPPIST-1 planets compared with the solar system. By adopting models from theoretical ecology, we show that the number of species transferred and the number of life-bearing planets are also likely to be higher because of the increased rates of immigration. We propose observational metrics for evaluating whether life was initiated by panspermia on multiple planets in the TRAPPIST-1 system. These results are also applicable to habitable exoplanets and exomoons in other planetary systems.

  18. Exotic states in the S=1 N-pi-K system and low-lying 1/2+ S=-1 resonances

    Directory of Open Access Journals (Sweden)

    Oset E.

    2010-04-01

    Full Text Available In this manuscript we discuss about our study of the $N pi ar{K}$ and the NπK systems made by solving the Faddeev equations with the two-body t-matrices obtained by solving the Bethe-Salpeter equations with the potentials obtained from chiral dynamics. In the strangeness = -1 case, we found that all the Λ and Σ resonances listed by the particle data group, with spin-parity 1/2+ , in the 1550-1800 MeV region get generated due to the involved three-body dynamics. This motivated us to study the strangeness =1 three-body system, i.e., NπK , where we did not find any evidence for the Θ+ (1542 but found a broad bump around 1700 MeV which has a κ(800N structure.

  19. The new school absentees reporting system for pandemic influenza A/H1N1 2009 infection in Japan.

    Directory of Open Access Journals (Sweden)

    Takeshi Suzue

    Full Text Available To evaluate the new Japanese School Absentees Reporting System for Infectious Disease (SARSID for pandemic influenza A/H1N1 2009 infection in comparison with the National epidemiological Surveillance of Infectious Disease (NESID.We used data of 53,223 students (97.7% in Takamatsu city Japan. Data regarding school absentees in SARSID was compared with that in NESID from Oct 13, 2009 to Jan 12, 2010.Similar trends were observed both in SARSID and NESID. However, the epidemic trend for influenza in SARSID was thought to be more sensitive than that in NESID.The epidemic trend for influenza among school-aged children could be easily and rapidly assessed by SARSID compared to NESID. SARSID might be useful for detecting the epidemic trend of influenza.

  20. Assessment of core thermo-hydrodynamic models of REFLA-1D with CCTF data

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Murao, Yoshio

    1983-07-01

    In order to assess the core thermo-hydrodynamic models of REFLA-1D/MODE3, which is the latest version of REFLA-1D, several calculations of the core thermo-hydrodynamics have been performed for the CCTF Core-I series tests. The measured initial and boundary conditions were used for these calculations. The calculational results showed that the water accumulation model of Case 2 could predict the CCTF results fairly well as it could for the JAERI small scale facility. The calculated results for the base case and the EM tests were in good agreement with the CCTF data. The parameter effects, such as system pressure, initial clad temperature, Acc injection rate, LPCI injection rate and initial down-comer wall temperature, were predicted correctly, except for the high system pressure and the high LPCI injection rate tests. (author)

  1. Meis1: effects on motor phenotypes and the sensorimotor system in mice

    Directory of Open Access Journals (Sweden)

    Aaro V. Salminen

    2017-08-01

    Full Text Available MEIS1 encodes a developmental transcription factor and has been linked to restless legs syndrome (RLS in genome-wide association studies. RLS is a movement disorder leading to severe sleep reduction and has a substantial impact on the quality of life of patients. In genome-wide association studies, MEIS1 has consistently been the gene with the highest effect size and functional studies suggest a disease-relevant downregulation. Therefore, haploinsufficiency of Meis1 could be the system with the most potential for modeling RLS in animals. We used heterozygous Meis1-knockout mice to study the effects of Meis1 haploinsufficiency on mouse behavioral and neurological phenotypes, and to relate the findings to human RLS. We exposed the Meis1-deficient mice to assays of motor, sensorimotor and cognitive ability, and assessed the effect of a dopaminergic receptor 2/3 agonist commonly used in the treatment of RLS. The mutant mice showed a pattern of circadian hyperactivity, which is compatible with human RLS. Moreover, we discovered a replicable prepulse inhibition (PPI deficit in the Meis1-deficient animals. In addition, these mice were hyposensitive to the PPI-reducing effect of the dopaminergic receptor agonist, highlighting a role of Meis1 in the dopaminergic system. Other reported phenotypes include enhanced social recognition at an older age that was not related to alterations in adult olfactory bulb neurogenesis previously shown to be implicated in this behavior. In conclusion, the Meis1-deficient mice fulfill some of the hallmarks of an RLS animal model, and revealed the role of Meis1 in sensorimotor gating and in the dopaminergic systems modulating it.

  2. MISTRAL V1.1.1: assessing doses from atmospheric releases in normal and off-normal conditions

    International Nuclear Information System (INIS)

    David Kerouanton; Patrick Devin; Malvina Rennesson

    2006-01-01

    Protecting the environment and the public from radioactive and chemical hazards has always been a top priority for all companies operating in the nuclear domain. In this scope, SGN provides all the services the nuclear industry needs in environmental studies especially in relation to the impact assessment in normal operating conditions and risk assessment in off-normal conditions. In order to quantify dose impact on members of the public due to atmospheric releases, COGEMA and SGN developed MISTRAL V1.1.1 code. Dose impact depends strongly on dispersion of radionuclides in atmosphere. The main parameters involved in dispersion characterization are wind velocity and direction, rain, diffusion conditions, coordinates of the point of observation and stack elevation. MISTRAL code implements DOURY and PASQUILL Gaussian plume models which are widely used in the scientific community. These models, applicable for distances of transfer ranging from 100 m up to 30 km, are used to calculate atmospheric concentration and deposit at different distances from the point of release. MISTRAL allows the use of different dose regulations or dose coefficient databases such as: - ICRP30 and ICPR71 for internal doses (inhalation, ingestion) - Despres/Kocher database or US-EPA Federal Guidance no.12 (ICPR72 for noble gases) for external exposure (from plume or ground). The initial instant of the release can be considered as the origin of time or a date format can be specified (could be useful in a crisis context). While the context is specified, the user define the meteorological conditions of the release. In normal operating mode (routine releases), the user gives the annual meteorological scheme. The data can be recorded in the MISTRAL meteorological database. In off-normal conditions mode, MISTRAL V1.1 allows the use of successive release stages for which the user gives the duration, the meteorological conditions, that is to say stability class, wind speed and direction and rainfall

  3. LRSYS, PASCAL LR(1) Parser Generator System

    International Nuclear Information System (INIS)

    O'Hair, K.

    1991-01-01

    Description of program or function: LRSYS is a complete LR(1) parser generator system written entirely in a portable subset of Pascal. The system, LRSYS, includes a grammar analyzer program (LR) which reads a context-free (BNF) grammar as input and produces LR(1) parsing tables as output, a lexical analyzer generator (LEX) which reads regular expressions created by the REG process as input and produces lexical tables as output, and various parser skeletons that get merged with the tables to produce complete parsers (SMAKE). Current parser skeletons include Pascal, FORTRAN 77, and C. In addition, the CRAY1, DEC VAX11 version contains LRLTRAN and CFT- FORTRAN 77 skeletons. Other language skeletons can easily be added to the system. LRSYS is based on the LR program (NESC Abstract 822)

  4. PATRAM '80. Proceedings. Volume 1

    International Nuclear Information System (INIS)

    Huebner, H.W.

    1980-01-01

    Volume 1 contains papers from the following sessions: Plenary Session; Regulations, Licensing and Standards; LMFBR Systems Concepts; Risk/Safety Assessment I; Systems and Package Design; US Institutional Issues; Risk/Safety Assessment II; Leakage, Leak Rate and Seals; Poster Session A; Operations and Systems Experience I; Manufacturing Processes and Materials; and Quality Assurance and Maintenance. Individual papers were processed. (LM)

  5. 12 CFR 1400.1 - Farm Credit System Insurance Corporation.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Farm Credit System Insurance Corporation. 1400.1 Section 1400.1 Banks and Banking FARM CREDIT SYSTEM INSURANCE CORPORATION ORGANIZATION AND FUNCTIONS Organization and Functions § 1400.1 Farm Credit System Insurance Corporation. The Farm Credit...

  6. Doxorubicin impairs the insulin-like growth factor-1 system and causes insulin-like growth factor-1 resistance in cardiomyocytes.

    Directory of Open Access Journals (Sweden)

    Patrizia Fabbi

    Full Text Available Insulin-like growth factor-1 (IGF-1 promotes the survival of cardiomyocytes by activating type 1 IGF receptor (IGF-1R. Within the myocardium, IGF-1 action is modulated by IGF binding protein-3 (IGFBP-3, which sequesters IGF-1 away from IGF-1R. Since cardiomyocyte apoptosis is implicated in anthracycline cardiotoxicity, we investigated the effects of the anthracycline, doxorubicin, on the IGF-1 system in H9c2 cardiomyocytes.Besides inducing apoptosis, concentrations of doxorubicin comparable to those observed in patients after bolus infusion (0.1-1 µM caused a progressive decrease in IGF-1R and increase in IGFBP-3 expression. Exogenous IGF-1 was capable to rescue cardiomyocytes from apoptosis triggered by 0.1 and 0.5 µM, but not 1 µM doxorubicin. The loss of response to IGF-1 was paralleled by a significant reduction in IGF-1 availability and signaling, as assessed by free hormone levels in conditioned media and Akt phosphorylation in cell lysates, respectively. Doxorubicin also dose-dependently induced p53, which is known to repress the transcription of IGF1R and induce that of IGFBP3. Pre-treatment with the p53 inhibitor, pifithrin-α, prevented apoptosis and the changes in IGF-1R and IGFBP-3 elicited by doxorubicin. The decrease in IGF-1R and increase in IGFBP-3, as well as apoptosis, were also antagonized by pre-treatment with the antioxidant agents, N-acetylcysteine, dexrazoxane, and carvedilol.Doxorubicin down-regulates IGF-1R and up-regulates IGFBP-3 via p53 and oxidative stress in H9c2 cells. This leads to resistance to IGF-1 that may contribute to doxorubicin-initiated apoptosis. Further studies are needed to confirm these findings in human cardiomyocytes and explore the possibility of manipulating the IGF-1 axis to protect against anthracycline cardiotoxicity.

  7. MINPACK-1, Subroutine Library for Nonlinear Equation System

    International Nuclear Information System (INIS)

    Garbow, Burton S.

    1984-01-01

    1 - Description of problem or function: MINPACK1 is a package of FORTRAN subprograms for the numerical solution of systems of non- linear equations and nonlinear least-squares problems. The individual programs are: Identification/Description: - CHKDER: Check gradients for consistency with functions, - DOGLEG: Determine combination of Gauss-Newton and gradient directions, - DPMPAR: Provide double precision machine parameters, - ENORM: Calculate Euclidean norm of vector, - FDJAC1: Calculate difference approximation to Jacobian (nonlinear equations), - FDJAC2: Calculate difference approximation to Jacobian (least squares), - HYBRD: Solve system of nonlinear equations (approximate Jacobian), - HYBRD1: Easy-to-use driver for HYBRD, - HYBRJ: Solve system of nonlinear equations (analytic Jacobian), - HYBRJ1: Easy-to-use driver for HYBRJ, - LMDER: Solve nonlinear least squares problem (analytic Jacobian), - LMDER1: Easy-to-use driver for LMDER, - LMDIF: Solve nonlinear least squares problem (approximate Jacobian), - LMDIF1: Easy-to-use driver for LMDIF, - LMPAR: Determine Levenberg-Marquardt parameter - LMSTR: Solve nonlinear least squares problem (analytic Jacobian, storage conserving), - LMSTR1: Easy-to-use driver for LMSTR, - QFORM: Accumulate orthogonal matrix from QR factorization QRFAC Compute QR factorization of rectangular matrix, - QRSOLV: Complete solution of least squares problem, - RWUPDT: Update QR factorization after row addition, - R1MPYQ: Apply orthogonal transformations from QR factorization, - R1UPDT: Update QR factorization after rank-1 addition, - SPMPAR: Provide single precision machine parameters. 4. Method of solution - MINPACK1 uses the modified Powell hybrid method and the Levenberg-Marquardt algorithm

  8. Constructing conditionally integrable evolution systems in (1+1) dimensions: a generalization of invariant modules approach

    International Nuclear Information System (INIS)

    Sergyeyev, A.

    2002-01-01

    Given a generalized (Lie-Baecklund) vector field satisfying certain nondegeneracy assumptions, we explicitly describe all (1+1)-dimensional evolution systems that admit this vector field as a generalized conditional symmetry. The connection with the theory of symmetries of systems of ODEs and with the theory of invariant modules is discussed. (author)

  9. A Security Level Classification Method for Power Systems under N-1 Contingency

    Directory of Open Access Journals (Sweden)

    Zhigang Lu

    2017-12-01

    Full Text Available Security assessment is crucial for the reliable and secure operation of power systems. This paper proposes a security level classification (SLC method to analyze the security level of power systems both qualitatively and quantitatively. In this SLC method, security levels are graded according to a comprehensive safety index (CSI, which is defined by integrating the system margin index (SMI and load entropy. The SMI depends on the operating load and the total supply capacity (TSC under N-1 contingency, and the load entropy reflects the heterogeneity of load distribution calculated from entropy theory. In order to calculate the TSC under N-1 contingency considering both of the computational accuracy and speed, the TSC is converted into an extended conic quadratic programming (ECQP model. In addition, the load boundary vector (LBV model is established to obtain the capacity limit of each load bus, and thus detect potential risks of power systems. Finally, two modified practical power systems and the IEEE 118-bus test system are studied to validate the feasibility of the proposed SLC method.

  10. Data acquisition system for TBR-1

    International Nuclear Information System (INIS)

    Fagundes, A.N.

    1989-07-01

    The data acquisition system of Tokamak TBR-1 has as goal to obtain retrieval signal from diagnostic systems. The final process of storage, register and transfer of the signals is described. The hardware used to convert the signals and its storage and the software developed for the operation are discussed [pt

  11. The H1 SPACAL time-to-digital converter system

    International Nuclear Information System (INIS)

    Eisenhandler, E.; Landon, M.; Thompson, G.

    1995-01-01

    This paper describes a pipelined 1,400-channel Time-to-Digital Converter (TDC) system for the H1 Scintillating Fiber Calorimeter, which will soon be installed in the H1 experiment at DESY. The main task of the TDC system is to determine the time of arrival of energy depositions, and send this information from bunch crossings that satisfy the event trigger into the H1 data acquisition system. In addition, the TDC system must monitor the timing trigger, which vetoes bunch crossings that contain too much background energy. Products of the interaction are separated from background on the basis of their different times of arrival with respect to the bunch crossing clock. For this monitoring the TDC system uses automatic on-board histogramming hardware that produces a family of histograms for each of 1,400 channels. The TDC function is performed by the TMC1004 ASIC. The system digitizes over a range of 32ns per bunch crossing with 1ns bins and a precision of 1ns. Because of the way the TMC1004 is designed, it is possible to vary the size of the bins between 0.6ns and 3ns by trading off measurement range for bin size. The system occupies two 9U VME crates

  12. Machine Control System of Steady State Superconducting Tokamak-1

    Energy Technology Data Exchange (ETDEWEB)

    Masand, Harish, E-mail: harish@ipr.res.in; Kumar, Aveg; Bhandarkar, M.; Mahajan, K.; Gulati, H.; Dhongde, J.; Patel, K.; Chudasma, H.; Pradhan, S.

    2016-11-15

    Highlights: • Central Control System. • SST-1. • Machine Control System. - Abstract: Central Control System (CCS) of the Steady State Superconducting Tokamak-1 (SST-1) controls and monitors around 25 plant and experiment subsystems of SST-1 located remotely from the Central-Control room. Machine Control System (MCS) is a supervisory system that sits on the top of the CCS hierarchy and implements the CCS state diagram. MCS ensures the software interlock between the SST-1 subsystems with the CCS, any subsystem communication failure or its local error does not prohibit the execution of the MCS and in-turn the CCS operation. MCS also periodically monitors the subsystem’s status and their vital process parameters throughout the campaign. It also provides the platform for the Central Control operator to visualize and exchange remotely the operational and experimental configuration parameters with the sub-systems. MCS remains operational 24 × 7 from the commencement to the termination of the SST-1 campaign. The developed MCS has performed robustly and flawlessly during all the last campaigns of SST-1 carried out so far. This paper will describe various aspects of the development of MCS.

  13. Environmental assessment for Breeder Reprocessing Engineering Test (BRET): Revision 1

    International Nuclear Information System (INIS)

    Lerch, R.E.

    1989-03-01

    This Environmental Assessment (EA) is for the proposed installation and operation of an integrated breeder fuel reprocessing test system in the shielded cells of the Fuels and Materials Examination Facility (FMEF) at Hanford and the associated modifications to the FMEF to accommodate BRET. These modifications would begin in FY-1986 subject to Congressional authorization. Hot operations would be scheduled to start in the early 1990's. The system, called the Breeder Reprocessing Engineering Test (BRET), is being designed to provide a test capability for developing the demonstrating fuel reprocessing, remote maintenance, and safeguards technologies for breeder reactor fuels. This EA describes (1) the action being proposed, (2) the existing environment which would be affected, (3) the potential environmental impacts from normal operations and severe accidents from the proposed action, (4) potential conflicts with federal, state, regional, and/or local plans for the area, and (5) environmental implications of alternatives considered to the proposed action. 41 refs., 10 figs., 31 tabs

  14. Global sensitivity analysis using emulators, with an example analysis of large fire plumes based on FDS simulations

    Energy Technology Data Exchange (ETDEWEB)

    Kelsey, Adrian [Health and Safety Laboratory, Harpur Hill, Buxton (United Kingdom)

    2015-12-15

    Uncertainty in model predictions of the behaviour of fires is an important issue in fire safety analysis in nuclear power plants. A global sensitivity analysis can help identify the input parameters or sub-models that have the most significant effect on model predictions. However, to perform a global sensitivity analysis using Monte Carlo sampling might require thousands of simulations to be performed and therefore would not be practical for an analysis based on a complex fire code using computational fluid dynamics (CFD). An alternative approach is to perform a global sensitivity analysis using an emulator. Gaussian process emulators can be built using a limited number of simulations and once built a global sensitivity analysis can be performed on an emulator, rather than using simulations directly. Typically reliable emulators can be built using ten simulations for each parameter under consideration, therefore allowing a global sensitivity analysis to be performed, even for a complex computer code. In this paper we use an example of a large scale pool fire to demonstrate an emulator based approach to global sensitivity analysis. In that work an emulator based global sensitivity analysis was used to identify the key uncertain model inputs affecting the entrainment rates and flame heights in large Liquefied Natural Gas (LNG) fire plumes. The pool fire simulations were performed using the Fire Dynamics Simulator (FDS) software. Five model inputs were varied: the fire diameter, burn rate, radiative fraction, computational grid cell size and choice of turbulence model. The ranges used for these parameters in the analysis were determined from experiment and literature. The Gaussian process emulators used in the analysis were created using 127 FDS simulations. The emulators were checked for reliability, and then used to perform a global sensitivity analysis and uncertainty analysis. Large-scale ignited releases of LNG on water were performed by Sandia National

  15. Management assessment of tank waste remediation system contractor readiness to proceed with phase 1B privatization

    International Nuclear Information System (INIS)

    Certa, P.J.

    1998-01-01

    Readiness to Proceed With Phase 1B Privatization documents the processes used to determine readiness to proceed with tank waste treatment technologies from private industry, now known as TWRS privatization. An overall systems approach was applied to develop action plans to support the retrieval and disposal mission of the TWRS Project. The systems and infrastructure required to support the mission are known. Required systems are either in place or plans have been developed to ensure they exist when needed. Since October 1996 a robust system engineering approach to establishing integrated Technical Baselines, work breakdown structures, tank farms organizational structure and configurations, work scope, and costs has become part of the culture within the TWRS Project. An analysis of the programmatic, management, and technical activities necessary to declare readiness to proceed with execution of the mission demonstrates that the system, personnel, and hardware will be on line and ready to support the private contractors. The systems approach included defining the retrieval and disposal mission requirements and evaluating the readiness of the Project Hanford Management Contract (PHMC) team to support initiation of waste processing by the private contractors in June 2002 and to receive immobilized waste shortly thereafter. The Phase 1 feed delivery requirements from the private contractor Requests for Proposal were reviewed. Transfer piping routes were mapped, existing systems were evaluated, and upgrade requirements were defined

  16. SIMS prototype system 1 test results: Engineering analysis

    Science.gov (United States)

    1978-01-01

    The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

  17. Assessment of myocardial fibrosis with T1 mapping MRI

    International Nuclear Information System (INIS)

    Everett, R.J.; Stirrat, C.G.; Semple, S.I.R.; Newby, D.E.; Dweck, M.R.; Mirsadraee, S.

    2016-01-01

    Myocardial fibrosis can arise from a range of pathological processes and its presence correlates with adverse clinical outcomes. Cardiac magnetic resonance (CMR) can provide a non-invasive assessment of cardiac structure, function, and tissue characteristics, which includes late gadolinium enhancement (LGE) techniques to identify focal irreversible replacement fibrosis with a high degree of accuracy and reproducibility. Importantly the presence of LGE is consistently associated with adverse outcomes in a range of common cardiac conditions; however, LGE techniques are qualitative and unable to detect diffuse myocardial fibrosis, which is an earlier form of fibrosis preceding replacement fibrosis that may be reversible. Novel T1 mapping techniques allow quantitative CMR assessment of diffuse myocardial fibrosis with the two most common measures being native T1 and extracellular volume (ECV) fraction. Native T1 differentiates normal from infarcted myocardium, is abnormal in hypertrophic cardiomyopathy, and may be particularly useful in the diagnosis of Anderson–Fabry disease and amyloidosis. ECV is a surrogate measure of the extracellular space and is equivalent to the myocardial volume of distribution of the gadolinium-based contrast medium. It is reproducible and correlates well with fibrosis on histology. ECV is abnormal in patients with cardiac failure and aortic stenosis, and is associated with functional impairment in these groups. T1 mapping techniques promise to allow earlier detection of disease, monitor disease progression, and inform prognosis; however, limitations remain. In particular, reference ranges are lacking for T1 mapping values as these are influenced by specific CMR techniques and magnetic field strength. In addition, there is significant overlap between T1 mapping values in healthy controls and most disease states, particularly using native T1, limiting the clinical application of these techniques at present.

  18. Assessment of myocardial fibrosis with T1 mapping MRI.

    Science.gov (United States)

    Everett, R J; Stirrat, C G; Semple, S I R; Newby, D E; Dweck, M R; Mirsadraee, S

    2016-08-01

    Myocardial fibrosis can arise from a range of pathological processes and its presence correlates with adverse clinical outcomes. Cardiac magnetic resonance (CMR) can provide a non-invasive assessment of cardiac structure, function, and tissue characteristics, which includes late gadolinium enhancement (LGE) techniques to identify focal irreversible replacement fibrosis with a high degree of accuracy and reproducibility. Importantly the presence of LGE is consistently associated with adverse outcomes in a range of common cardiac conditions; however, LGE techniques are qualitative and unable to detect diffuse myocardial fibrosis, which is an earlier form of fibrosis preceding replacement fibrosis that may be reversible. Novel T1 mapping techniques allow quantitative CMR assessment of diffuse myocardial fibrosis with the two most common measures being native T1 and extracellular volume (ECV) fraction. Native T1 differentiates normal from infarcted myocardium, is abnormal in hypertrophic cardiomyopathy, and may be particularly useful in the diagnosis of Anderson-Fabry disease and amyloidosis. ECV is a surrogate measure of the extracellular space and is equivalent to the myocardial volume of distribution of the gadolinium-based contrast medium. It is reproducible and correlates well with fibrosis on histology. ECV is abnormal in patients with cardiac failure and aortic stenosis, and is associated with functional impairment in these groups. T1 mapping techniques promise to allow earlier detection of disease, monitor disease progression, and inform prognosis; however, limitations remain. In particular, reference ranges are lacking for T1 mapping values as these are influenced by specific CMR techniques and magnetic field strength. In addition, there is significant overlap between T1 mapping values in healthy controls and most disease states, particularly using native T1, limiting the clinical application of these techniques at present. Copyright © 2016 The Royal College

  19. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    Science.gov (United States)

    The IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was released for external peer review in September 2016. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the RDX assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  20. Neutronics optimization of LiPb-He dual-cooled fuel breeding blanket for the fusion-driven sub-critical system

    International Nuclear Information System (INIS)

    Zheng Shanliang; Wu Yican

    2002-01-01

    The concept of the liquid Li 17 Pb 83 and Helium gas dual-cooled Fuel Breeding Blanket (FBB) for the Fusion-Driven sub-critical System (FDS) is presented and analyzed. Taking self-sustaining tritium (TBR > 1.05) and annual output of 100 kg or more fissile 239 Pu (FBR > 0.238) as objective parameters, and based on the three-dimensional Monte Carlo neutron-photon transport code MCNP/4A, a neutronics-optimized calculation of different cases was carried out and the concept is proved feasible. In addition, the total breeding ratio (Br = Tbr + Fbr) is listed corresponding to different cases

  1. Assessment of a RELAP5 model for the IPR-R1 TRIGA research reactor

    International Nuclear Information System (INIS)

    Reis, Patricia A.L.; Costa, Antonella L.; Pereira, Claubia; Veloso, Maria A.F.; Mesquita, Amir Z.; Soares, Humberto V.

    2010-01-01

    RELAP5 code was developed at the Idaho National Environmental and Engineering Laboratory and it is widely used for thermal hydraulic studies of commercial nuclear power plants and, currently, it has been also applied for thermal hydraulic analysis of nuclear research systems with good predictions. This work is a contribution to the assessment of RELAP5/3.3 code for research reactors analysis. It presents steady-state and transient calculation results performed using a RELAP5 model to simulate the IPR-R1 TRIGA research reactor conditions operating at 50 and 100 kW. The reactor is located at the Nuclear Technology Development Centre (CDTN), Brazil. The development and the assessment of a RELAP5 model for the IPR-R1 TRIGA are presented. Experimental data were considered in the process of code-to-data validation. The RELAP5 results were also compared with calculation performed using the STHIRP-1 (Research Reactors Thermal Hydraulic Simulation) code. The use of a cross flow model has been essential to improve results in the transient condition respect to preceding investigations.

  2. Tuning metal–graphene interaction by non-metal intercalation: a case study of the graphene/oxygen/Ni (111) system

    International Nuclear Information System (INIS)

    Zhang, Wei-Bing; Chen, Chuan

    2015-01-01

    Epitaxial growth of graphene on transition metal surfaces has been proposed as one of the most promising methods for large-scale preparation of high-quality graphene. However, the presence of the substrate could significantly affect the intrinsic electronic structure of graphene and intercalation of metals is an established route for decoupling the graphene from the substrate. Taking a graphene/Ni(111) surface as an example, we suggest reactive oxygen as an effective intercalation element to recover the linear dispersion of graphene based on density functional theory calculation, in which vdW interactions are treated using the optB88-vdW functional. The possible intercalation configurations at different coverage are considered and the geometry and electronic structure are analyzed in detail. Our results indicate that the energy favorable structures change from top-fcc to bridge-top configuration after oxygen intercalation and the binding between the graphene and the O/Ni(111) substrate becomes stronger at high oxygen coverage even than pure Ni(111) substrate. Most interestingly, the electronic structure of pristine graphene is found to be almost restored, especially for the bridge-top configuration after oxygen intercalation, and the Dirac points move towards the high energy region relative to the Fermi level. A graphene/oxygen/Ni (111) system is thus suggested as a p-type doped strongly bound Dirac system. Detailed analysis using projected energy band and differential charge density indicates that the intercalated oxygen atoms react with the Ni (111) surface strongly, which not only blocks the strong interaction between Ni and graphene but also passivates oxygen 2p states. The intercalation mechanisms distinguished from the conventional metal intercalation will be useful to understand other complex intercalation systems. (paper)

  3. Project SAFE. Update of the SFR-1 safety assessment. Phase 1. Appendix A1: Inventory

    International Nuclear Information System (INIS)

    Riggare, P.

    1998-01-01

    One of the aims in the safety assessment of SFR-1 is to estimate the release to the environment. In order to make these calculations there is a need to describe the inventory in greater detail. The new computerised database of waste in SFR-1 gives a good possibility to achieve this. The aim for project SAFE is to make both conservative and realistic radionuclide transport calculations. To achieve this goal there must be two inventories. The conservative inventory is the inventory used in the design of the repository, which in most parts is identical with the limits in the licence for SFR-1. There is a great interest to have good estimates of the volumes of the different waste types. A thorough prognosis should be made in 1999, but until then the latest one from 1995 could be used in the calculations. The total (actual) inventory of nuclides is calculated from the measurements of the easy-to-measure nuclides since, in principle, all hard-to-measure nuclides are calculated by correlation factors to 60 Co and 137 Cs . These factors should be reviewed since there are quite large uncertainties involved. 14 C dominates the individual doses after a few hundred years and the collective dose in the inland-scenario. The amount of the nuclide is uncertain since the correlation factor is very uncertain. The chemical speciation of 14 C is also of interest due to different properties of organic and inorganic carbon. 36 Cl is very hard to measure. Although the authorities in their reviews of the safety reports say that there probably are small doses from chlorine, the inventory should be improved. 59 Ni is a long-lived nuclide that sets a limit to the close-to-the-core metal scrap that can be taken to SFR- 1. There is an ongoing research project to provide a better measuring method for 59 Ni. This should make it possible to improve the knowledge about 59 Ni inventory. The assumption that 90 % of the inventory is collected in the ion-exchange resins should be checked. Actinides

  4. X1X1X2X2/X1X2Y sex chromosome systems in the Neotropical Gymnotiformes electric fish of the genus Brachyhypopomus

    Directory of Open Access Journals (Sweden)

    Adauto Lima Cardoso

    2015-06-01

    Full Text Available Several types of sex chromosome systems have been recorded among Gymnotiformes, including male and female heterogamety, simple and multiple sex chromosomes, and different mechanisms of origin and evolution. The X1X1X2X2/X1X2Y systems identified in three species of this order are considered homoplasic for the group. In the genus Brachyhypopomus, only B. gauderio presented this type of system. Herein we describe the karyotypes of Brachyhypopomus pinnicaudatus and B. n. sp. FLAV, which have an X1X1X2X2/X1X2Y sex chromosome system that evolved via fusion between an autosome and the Y chromosome. The morphology of the chromosomes and the meiotic pairing suggest that the sex chromosomes of B. gauderio and B. pinnicaudatus have a common origin, whereas in B . n. sp. FLAV the sex chromosome system evolved independently. However, we cannot discard the possibility of common origin followed by distinct processes of differentiation. The identification of two new karyotypes with an X1X1X2X2/X1X2Y sex chromosome system in Gymnotiformes makes it the most common among the karyotyped species of the group. Comparisons of these karyotypes and the evolutionary history of the taxa indicate independent origins for their sex chromosomes systems. The recurrent emergence of the X1X1X2X2/X1X2Y system may represent sex chromosomes turnover events in Gymnotiformes.

  5. Sphingosine-1-phosphate signaling in the cardiovascular system

    NARCIS (Netherlands)

    Peters, Stephan L. M.; Alewijnse, Astrid E.

    2007-01-01

    Increasing evidence suggests a key role for the bioactive lipid sphingosine-1-phosphate (S1P) and its G-protein-coupled receptors (S1P(1-5)) in the cardiovascular system. Recent advances in sphingolipid research indicates that cardiomyocyte, vascular smooth muscle and endothelial cell function is

  6. System analytical assessment of the carbon balance in Austria. Final report part 1: carbon balance for 1990

    International Nuclear Information System (INIS)

    Orthofer, R.

    1997-09-01

    The report contains an analysis and quantification of the fluxes in the Austrian carbon system in 1990. Following subsystems were considered: agriculture, forestry, energy transformation and use, production and consumption of goods, and waste treatment. Austrian carbon imports and exports in products and goods were also quantified. The calculations for the forestry and agriculture sectors are based on the results of a dynamic model (cf. final report part 2) and for others on existing data or experts opinions. In total, Austria releases a net of 11,2 Mio t carbon (MTC) - which equals about 41,1 Mio t of CO 2 - into the atmosphere. This is about 1/3 less than the numbers for the 1990 carbon emission inventories which for 1990 were estimated with 17,0 MTC. Reasons for the differences between emission estimates and carbon balancing are the carbon storage in Austria's forests (5,3 MTC) and the mineralization of organic wastes (1,0 MTC) as well as other minor interactions. While the main pathway of carbon fluxes to the atmosphere goes from fossil fuel extraction and imports via the energy system, a considerable portion of carbon is transferred through other systems. This means in order to be able to plan effective greenhouse gas reduction strategies, the overall system must be considered. (author)

  7. IEA-R1 primary and secondary coolant piping systems coupled stress analysis

    International Nuclear Information System (INIS)

    Fainer, Gerson; Faloppa, Altair A.; Oliveira, Carlos A.; Mattar Neto, Miguel

    2013-01-01

    The aim of this work is to perform the stress analysis of a coupled primary and secondary piping system of the IEA-R1 based on tridimensional model, taking into account the as built conditions. The nuclear research reactor IEA-R1 is a pool type reactor projected by Babcox-Willcox, which is operated by IPEN since 1957. The operation to 5 MW power limit was only possible after the conduction of life management and modernization programs in the last two decades. In these programs the components of the coolant systems, which are responsible for the water circulation into the reactor core to remove the heat generated inside it, were almost totally refurbished. The changes in the primary and secondary systems, mainly the replacement of pump and heat-exchanger, implied in piping layout modifications, and, therefore, the stress condition of the piping systems had to be reanalyzed. In this paper the structural stress assessment of the coupled primary and secondary piping systems is presented and the final results are discussed. (author)

  8. Eletronic system for search of particles with 1-0.1 ps lifetime

    International Nuclear Information System (INIS)

    Bobkov, S.G.; Kantserov, V.A.; Pershin, A.S.

    1986-01-01

    The algorithms for search of short-lived particleswith 1-0.1 ps lifetime in a vertex detector based on drift chambers are considered. Electronics supply of such selecting by means ofthe suggested algorithms is described. The algorithms for useful event selecting in electron detectors are developed by pp-interaction simulation using the Monte-Carlo method. Events of two types are simulated: charm particle generation with theirfurther decay and interactions without charm particle generation. Two-dimensional interaction pattern is cnsidered. Some algorithms for data processing by the selecting systems (trigger systems) are developed. For all algorithms the event is considered to be useful, if more than one vertex is determined. The algorithms are based on geometrical relations for one-vertex events. Systematic deviation from these relations means that the event is multivertex

  9. Assessment of MSIV full closure for Santa Maria de Garona Nuclear Power Plant using TRAC-BF1 (G1J1)

    International Nuclear Information System (INIS)

    Crespo, J.L.

    1993-06-01

    This document presents a spurious Main Steam Isolation Value (MSIV) closure analysis for Santa Maria de Garorta Nuclear Power Plan describing the problems found when comparing calculated and real data. The plant is a General Electric Boiling Water Reactor 3, containment type Mark 1. It is operated by NUCLENOR, S.A. and was connected to the grid in 1971. The analysis has been performed by the Apphed Physics Department from the University of Cantabria and the Analysis and Operation Section from NUCLENOR, S.A. as a part of an agreement for developing an engineering simulator of operational transients and accidents for Santa Maria de Gamma Power Plant. The analysis was performed using the frozen version of TRAC-BFI (GlJl) code and is the second of two NUCLENOR contributions to the International Code Applications and Assessment Program (ICAP). The code was run in a Cyber 932 with operating system NOS/VE, property of NUCLENOR, S.A.. A programming effort was carried out in order to provide suitable graphics from the output file

  10. Air quality management and planning system for Guangzhou. Report from workshop 1, 1998

    International Nuclear Information System (INIS)

    Larssen, Steinar

    1999-02-01

    The report is proceedings from Workshop no. 1, 1998 of the Sino-Norwegian co-operation project ''Guangzhou Air Quality Management and Planning System''. The project studies pollution emissions generally and from coal, vehicle and energy activities, dispersion modelling, monitoring, exposure, health damage assessment, material damage assessment, vegetation, control options, baseline scenario development, cost benefit analysis, pollution control management and policy instruments and air pollution forecasting. A forth workshop is planned. There are several reports from the various project activities

  11. The IPIRG-1 pipe system fracture tests: Experimental results

    International Nuclear Information System (INIS)

    Scott, P.; Olson, R.J.; Wilkowski, G.M.

    1994-01-01

    As part of the First International Piping Integrity Research Group (IPIRG-1) program, six dynamic pipe system experiments were conducted. The objective of these experiments was to generate experimental data to assess analysis methodologies for characterizing the fracture behavior of circumferentially cracked pipe in a representative piping system subjected to combined inertial and displacement-controlled stresses. A unique experimental facility was designed and constructed. The pipe system evaluated was an expansion loop with over 30 m (100 feet) of 16-inch nominal diameter Schedule 100 pipe. The experimental facility was equipped with special hardware to ensure that system boundary conditions could be appropriately modeled. The test matrix involved one uncracked and five cracked dynamic pipe system experiments. The uncracked-pipe experiment was conducted to evaluate the piping system damping and natural frequency characteristics. The cracked-pipe experiments were conducted to evaluate the fracture behavior, piping system response, and fracture stability characteristics of five different materials. All cracked-pipe experiments were conducted at PWR conditions. Material characterization efforts provided the tensile and fracture toughness properties of the different pipe materials at various strain rates and temperatures. Key results from the six pipe system experiments and material characterization efforts are presented. Detailed analyses will be published in a companion paper

  12. Nuclear energy system department annual report. April 1, 2001 - March 31, 2002

    International Nuclear Information System (INIS)

    Nakajima, Hajime; Ohnuki, Akira; Kunii, Katsuhiko

    2003-03-01

    This report summarizes the research and development activities in the Department of Nuclear Energy System during the fiscal year of 2001 (April 1, 2001 - March 31, 2002). The Department has been organized from April 1998. The main research activity is aimed to build the basis of the development of future nuclear energy systems. The research activities of the Department cover basic nuclear data evaluation, conceptual design of a reduced-moderation water reactor, reactor physics experiments and development of the reactor analysis codes, experiment and analysis of thermal-hydrodynamics, energy system analysis and assessment, development of advanced materials for a reactor, lifetime reliability assessment on structural material, development of advanced nuclear fuel, design of a marine reactor and the research for a nuclear ship system. The maintenance and operation of reactor engineering facilities belonging to the Department are undertaken. The activities of the research committees to which the Department takes a role of secretariat are also summarized in this report. (author)

  13. (Vapour + liquid) equilibrium data for the {1,1-difluoroethane (R152a) + 1,1,1,3,3-pentafluoropropane (R245fa)} system at temperatures from (323.150 to 353.150) K

    International Nuclear Information System (INIS)

    Yang, Lixiang; Gong, Maoqiong; Guo, Hao; Dong, Xueqiang; Wu, Jianfeng

    2015-01-01

    Highlights: • VLE data for (R152a + R245fa) system were measured at temperatures. • The experiments were based on the static-analytic method. • VLE data were correlated using PR–vdWs and PR–HV–NRTL models. - Abstract: In this paper, (vapour + liquid) equilibrium (VLE) for the {1,1-difluoroethane (R152a) + 1,1,1,3,3-pentafluoropropane (R245fa)} system was determined by a static-analytical method at T = (323.150 to 353.150) K. Values of the VLE were correlated by the Peng–Robison equation of state (PR EoS) using two different models, the van der Waals (vdWs) mixing rule and the Huron–Vidal (HV) mixing rule involving the non-random two-liquid (NRTL) activity coefficient model. The correlated results show good agreement with the experimental values. For the two models, the maximum average absolute deviations of the vapour phase mole fraction are 0.0034 and 0.0035, respectively.

  14. Assessment of workers’ exposure to Aflatoxin B1 in a Portuguese waste industry

    OpenAIRE

    Viegas, Susana; Veiga, Luísa; Figueredo, Paula; Almeida, Ana; Carolino, Elisabete; Viegas, Carla

    2015-01-01

    Aflatoxin B1 (AFB1) is considered by different International Agencies as a genotoxic and potent hepatocarcinogen. However, despite the fact that the fungi producing this compound are detected in some work environments, AFB1 is rarely monitored in occupational settings. The aim of the present investigation was to assess exposure to AFB1 of workers from one Portuguese waste company located in the outskirt of Lisbon. Occupational exposure assessment to AFB1 was done with a biomarker of internal ...

  15. Function of the EGR-1/TIS8 radiation inducible promoter in a minimal HSV-1 amplicon system

    International Nuclear Information System (INIS)

    Spear, M.A.; Sakamoto, K.M.; Herrlinger, U.; Pechan, P.; Breakefield, X.O.

    1997-01-01

    Purpose: To evaluate function of the EGR-1/TIS8 promoter region in minimal HSV-1 amplicon system in order to determine the feasibility of using the system to regulate vector replication with radiation. Materials and Methods: A 600-base pair 5' upstream region of the EGR-1 promoter linked to chloramphenicol acetyltransferase (CAT) was recombined into a minimal HSV-1 amplicon vector system (pONEC). pONEC or a control plasmid was transfected into U87 glioma cells using the Lipofectamine method. Thirty-six hours later one aliquot of cells from each transfection was irradiated to a dose of 20 Gy and another identical aliquot served as a control. CAT activity was assayed 8 hours after irradiation. Results: pONEC transfected cells irradiated with 20 Gy demonstrated 2.0 fold increase in CAT activity compared to non-irradiated cells. Cells transfected with control plasmid showed no change in CAT activity. Unirradiated pONEC cells had CAT activity 1.3 times those transfected with control plasmid. Conclusion: We have previously created HSV-1 gene therapy amplicon vector systems which allow virus-amplicon interdependent replication, with the intent of regulating replication. The above data demonstrates that a minimal amplicon system will allow radiation dependent regulation by the EGR-1 promoter, thus indicating the possibility of using this system to regulate onsite, spatially and temporally regulated vector production. Baseline CAT activity was higher and relative induction lower than other reported expression constructs, which raises concern for the ability of the system to produce a differential in transcription levels sufficient for this purpose. This is possibly the result of residual promoter/enhancer elements remaining in the HSV-1 sequences. We are attempting to create constructs lacking these elements. Addition of secondary promoter sequences may also be of use. We are also currently evaluating the efficacy of the putative IEX-1 radiation inducible promoter region in

  16. Study on interaction between palladium(ІІ)-Linezolid chelate with eosin by resonance Rayleigh scattering, second order of scattering and frequency doubling scattering methods using Taguchi orthogonal array design

    Science.gov (United States)

    Thakkar, Disha; Gevriya, Bhavesh; Mashru, R. C.

    2014-03-01

    Linezolid reacted with palladium to form 1:1 binary cationic chelate which further reacted with eosin dye to form 1:1 ternary ion association complex at pH 4 of Walpole's acetate buffer in the presence of methyl cellulose. As a result not only absorption spectra were changed but Resonance Rayleigh Scattering (RRS), Second-order Scattering (SOS) and Frequency Doubling Scattering (FDS) intensities were greatly enhanced. The analytical wavelengths of RRS, SOS and FDS (λex/λem) of ternary complex were located at 538 nm/538 nm, 240 nm/480 nm and 660 nm/330 nm, respectively. The linearity range for RRS, SOS and FDS methods were 0.01-0.5 μg mL-1, 0.1-2 μg mL-1 and 0.2-1.8 μg mL-1, respectively. The sensitivity order of three methods was as RRS > SOS > FDS. Accuracy of all methods were determined by recovery studies and showed recovery between 98% and 102%. Intraday and inter day precision were checked for all methods and %RSD was found to be less than 2 for all methods. The effects of foreign substances were tested on RRS method and it showed the method had good selectivity. For optimization of process parameter, Taguchi orthogonal array design L8(24) was used and ANOVA was adopted to determine the statistically significant control factors that affect the scattering intensities of methods. The reaction mechanism, composition of ternary ion association complex and reasons for scattering intensity enhancement was discussed in this work.

  17. Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR

    International Nuclear Information System (INIS)

    Nagashima, Chieko; Uchiyama, Nachiko; Moriyama, Noriyuki; Nagata, Mio; Kobayashi, Hiroyuki; Sankoda, Katsuhiro; Saotome, Shigeru; Tagi, Masahiro; Kusunoki, Tetsurou

    2009-01-01

    Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the digital phantom. The values utilizing the 1Shot Phantom and those from the European guidelines and IEC standards were consistent, but the QC tests for the European guidelines and IEC standards methods took about six hours while the same QC tests using the 1Shot Phantom took 10 minutes or less including exposure of the phantom image, measurement, and analysis. In conclusion, the digital phantom and dedicated software proved very useful and produced improved analysis for mammography systems using FCR in clinical daily QC testing because of their objectivity and substantial time-saving convenience. (author)

  18. Vacuum system of SST-1 Tokamak

    International Nuclear Information System (INIS)

    Khan, Ziauddin; Pathan, Firozkhan; George, Siju; Semwal, Pratibha; Dhanani, Kalpesh; Paravastu, Yuvakiran; Thankey, Prashant; Ramesh, Gattu; Himabindu, Manthena; Pradhan, Subrata

    2013-01-01

    Highlights: ► Air leaks developed during ongoing SST-1 cooldown campaign were detected online using RGA. ► The presence of N 2 and O 2 gases with the ratio of their partial pressures with ∼3.81:1 confirmed the air leaks. ► Baking of SST-1 was done efficiently by flowing hot N 2 gas in C-channels welded on inner surfaces without any problem. ► In-house fabricated demountable bull nose couplers were demonstrated for high temperature and pressure applications. ► Cryopumping effect was observed when liquid helium cooled superconducting magnets reached below 63 K. -- Abstract: Vacuum chambers of Steady State Superconducting (SST-1) Tokamak comprises of the vacuum vessel and the cryostat. The plasma will be confined inside the vacuum vessel while the cryostat houses the superconducting magnet systems (TF and PF coils), LN 2 cooled thermal shields and hydraulics for these circuits. The vacuum vessel is an ultra-high (UHV) vacuum chamber while the cryostat is a high-vacuum (HV) chamber. In order to achieve UHV inside the vacuum vessel, it would be baked at 150 °C for longer duration. For this purpose, U-shaped baking channels are welded inside the vacuum vessel. The baking will be carried out by flowing hot nitrogen gas through these channels at 250 °C at 4.5 bar gauge pressure. During plasma operation, the pressure inside the vacuum vessel will be raised between 1.0 × 10 −4 mbar and 1.0 × 10 −5 mbar using piezoelectric valves and control system. An ultimate pressure of 4.78 × 10 −6 mbar is achieved inside the vacuum vessel after 100 h of pumping. The limitation is due to the development of few leaks of the order of 10 −5 mbar l/s at the critical locations of the vacuum vessel during baking which was confirmed with the presence of nitrogen gas and oxygen gas with the ratio of ∼3.81:1 indicating air leak. Similarly an ultimate vacuum of 2.24 × 10 −5 mbar is achieved inside the cryostat. Baking of the vacuum vessel up to 110 °C with ±10

  19. Assessment of Silent T1-weighted head imaging at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Costagli, Mauro; Tiberi, Gianluigi; Tosetti, Michela [Imago7 Foundation, Pisa (Italy); IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Symms, Mark R. [GE Applied Science Laboratory, Pisa (Italy); Angeli, Lorenzo [University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Kelley, Douglas A.C. [GE Healthcare Technologies, San Francisco, CA (United States); Biagi, Laura [IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Farnetani, Andrea [University of Ferrara, Engineering Department, Ferrara (Italy); Materiacustica s.r.l., Ferrara (Italy); Rua, Catarina [University of Pisa, Department of Physics, Pisa (Italy); Donatelli, Graziella [Azienda Ospedaliero-Universitaria Pisana (AOUP), Neuroradiology Unit, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Cosottini, Mirco [Imago7 Foundation, Pisa (Italy); University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy)

    2016-06-15

    This study aimed to assess the performance of a ''Silent'' zero time of echo (ZTE) sequence for T1-weighted brain imaging using a 7 T MRI system. The Silent sequence was evaluated qualitatively by two neuroradiologists, as well as quantitatively in terms of tissue contrast, homogeneity, signal-to-noise ratio (SNR) and acoustic noise. It was compared to conventional T1-weighted imaging (FSPGR). Adequacy for automated segmentation was evaluated in comparison with FSPGR acquired at 7 T and 1.5 T. Specific absorption rate (SAR) was also measured. Tissue contrast and homogeneity in Silent were remarkable in deep brain structures and in the occipital and temporal lobes. Mean tissue contrast was significantly (p < 0.002) higher in Silent (0.25) than in FSPGR (0.11), which favoured automated tissue segmentation. On the other hand, Silent images had lower SNR with respect to conventional imaging: average SNR of FSPGR was 2.66 times that of Silent. Silent images were affected by artefacts related to projection reconstruction, which nevertheless did not compromise the depiction of brain tissues. Silent acquisition was 35 dB(A) quieter than FSPGR and less than 2.5 dB(A) louder than ambient noise. Six-minute average SAR was <2 W/kg. The ZTE Silent sequence provides high-contrast T1-weighted imaging with low acoustic noise at 7 T. (orig.)

  20. Assessing Progress in Retinopathy Outcomes in Type 1 Diabetes

    Science.gov (United States)

    LeCaire, Tamara J.; Palta, Mari; Klein, Ronald; Klein, Barbara E.K.; Cruickshanks, Karen J.

    2013-01-01

    OBJECTIVE The Wisconsin Diabetes Registry Study (WDRS) cohort consisted of patients diagnosed with type 1 diabetes in the same geographic region as, but 8–34 years later than the Wisconsin Epidemiologic Study of Diabetic Retinopathy (WESDR) cohort, providing a unique opportunity to assess changes in complications. We estimated the current prevalence and severity of diabetic retinopathy at 20 years of diabetes duration, compared these between eras, and evaluated the influence of diabetes management. RESEARCH DESIGN AND METHODS Twenty-year examinations, including fundus photographs, were completed on 305 WDRS subjects during 2007–2011. A subgroup of the WESDR cohort participated in one of four study visits during 1980–1996, at similar diabetes duration (n = 583). Adjusted ordinal logistic regression with three retinopathy severity categories was used to estimate odds ratios (ORs) of more severe retinopathy with diagnosis during an earlier era. RESULTS Mean hemoglobin A1c (HbA1c) was lower in WDRS than in WESDR (8.0% vs. 9.3% [P < 0.001], and 93.4% vs. 21.3% [P < 0.001]) used ≥3 daily insulin injections or an insulin pump. In WDRS, 18% had vision-threatening levels of retinopathy vs. 43% in WESDR. The adjusted OR of more severe retinopathy in the earlier era (OR 3.0 [95% CI 2.2–4.0]) was reduced by including 20-year HbA1c in the model (OR 2.2 [1.6–3.0]). CONCLUSIONS Retinopathy severity at a diabetes duration of 20 years is lower in the more recent era of type 1 diabetes. Updated projections should be used when informing newly diagnosed individuals of prognosis and for health care cost assessments. Current glycemic control explained a limited amount of the difference. PMID:23193204

  1. CL-L1 and CL-K1 and other complement associated pattern recognition molecules in systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Troldborg, Anne; Thiel, Steffen; Jensen, Lisbeth

    2015-01-01

    The objective of this study was to explore the involvement of collectin liver 1 (CL-L1) and collectin kidney 1 (CL-K1) and other pattern recognition molecules (PRMs) of the lectin pathway of the complement system in a cross-sectional cohort of systemic lupus erythematosus (SLE) patients...

  2. Second interim assessment of the Canadian concept for nuclear fuel waste disposal. Volume 1

    International Nuclear Information System (INIS)

    Wuschke, D.M.; Gillespie, P.A.; Main, D.E.

    1985-07-01

    The nuclear fuel waste disposal concept chosen for development and assessment in Canada involves the isolation of corrosion-resistant containers of waste in a vault located deep in plutonic rock. As the concept and the assessment tools are developed, periodic assessments are performed to permit evaluation of the methodology and provide feedback to those developing the concept. The ultimate goal of these assessments is to predict what impact the disposal system would have on man and the environment if the concept were implemented. The second assessment was performed in 1984 and is documented in the Second Interim assessment of the Canadian Concept for Nuclear Fuel Waste Disposal Volumes 1 to 4. This volume, entitled Summary, is a condensation of Volumes 2, 3 and 4. It briefly describes the Canadian nuclear fuel waste disposal concept, and the methods and results of the second interim pre-closure and post-closure assessments of that concept. 46 refs

  3. Results of the Level 1 probabilistic risk assessment (PRA) of internal events for heavy water production reactors (U)

    International Nuclear Information System (INIS)

    Tinnes, S.P.; Cramer, D.S.; Logan, V.E.; Topp, S.V.; Smith, J.A.; Brandyberry, M.D.

    1990-01-01

    This paper reports on a full-scope probabilistic risk assessment (PRA) performed for the Savannah River Site (SRS) production reactors. The Level 1 PRA for the K Reactor has been completed and includes the assessment of reactor systems response to accidents and estimates of the severe core melt frequency (SCMF). The internal events spectrum includes those events related directly to plant systems and safety functions for which transients or failures may initiate an accident

  4. Design of mass flow rate measurement system for SST-1 superconducting magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Varmora, P., E-mail: pvamora@ipr.res.in; Sharma, A.N.; Khristi, Y.; Prasad, U.; Patel, D.; Doshi, K.; Pradhan, S.

    2016-11-15

    Highlights: • Design of Venturi meter for SST-1 magnet system. • Details of Helium mass flow measurement system used in SST-1. • Instruments and measurement techniques for flow measurement. • VME based data acquisition system details and flow calculation and results from SST-1 campaigns. - Abstract: Superconducting Magnet System (SCMS) of Steady State Superconducting Tokamak – 1 (SST-1) is forced-flow cooled by a closed cycle 1.3 kW (at 4.5 K) class Helium Refrigerator cum Liquefier (HRL) system. An accurate measurement of helium mass flow rate in different coils is required to ensure the uniform cooling of the cold mass in the entire range of operating temperature (300 K to 4.5 K) and pressure (0.9–0.4 MPa). To meet this requirement, indigenously designed and fabricated venturi meters are installed on 27 different coils of SST-1 SCMS. A VME based Data Acquisition System (DAS) has been developed and used to acquire the flow measurement data from different flowmeters. The details of the design of venturi meter, its different measurement and signal conditioning components, the data acquisition system and the mass flow rate calculation method are described in this paper. The mass flow rate measurement data from cryogenic acceptance and SST-1 magnet commissioning experiments are also presented and discussed in this paper.

  5. Design of mass flow rate measurement system for SST-1 superconducting magnet system

    International Nuclear Information System (INIS)

    Varmora, P.; Sharma, A.N.; Khristi, Y.; Prasad, U.; Patel, D.; Doshi, K.; Pradhan, S.

    2016-01-01

    Highlights: • Design of Venturi meter for SST-1 magnet system. • Details of Helium mass flow measurement system used in SST-1. • Instruments and measurement techniques for flow measurement. • VME based data acquisition system details and flow calculation and results from SST-1 campaigns. - Abstract: Superconducting Magnet System (SCMS) of Steady State Superconducting Tokamak – 1 (SST-1) is forced-flow cooled by a closed cycle 1.3 kW (at 4.5 K) class Helium Refrigerator cum Liquefier (HRL) system. An accurate measurement of helium mass flow rate in different coils is required to ensure the uniform cooling of the cold mass in the entire range of operating temperature (300 K to 4.5 K) and pressure (0.9–0.4 MPa). To meet this requirement, indigenously designed and fabricated venturi meters are installed on 27 different coils of SST-1 SCMS. A VME based Data Acquisition System (DAS) has been developed and used to acquire the flow measurement data from different flowmeters. The details of the design of venturi meter, its different measurement and signal conditioning components, the data acquisition system and the mass flow rate calculation method are described in this paper. The mass flow rate measurement data from cryogenic acceptance and SST-1 magnet commissioning experiments are also presented and discussed in this paper.

  6. Progress in passive solar energy systems. Volume 8. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, J.; Andrejko, D.A.

    1983-01-01

    This book presents the papers given at a conference sponsored by the US DOE, the Solar Energy Research Institute, SolarVision, Inc., and the Southern California Solar Energy Society. The topics considered at the conference included sizing solar energy systems for agricultural applications, a farm scale ethanol production plant, the EEC wind energy RandD program, the passive solar performance assessment of an earth-sheltered house, the ARCO 1 MW photovoltaic power plant, the performance of a dendritic web photovoltaic module, second generation point focused concentrators, linear fresnel lens concentrating photovoltaic collectors, photovoltaic conversion efficiency, amorphous silicon thin film solar cells, a photovoltaic system for a shopping center, photovoltaic power generation for the utility industry, spectral solar radiation, and the analysis of insolation data.

  7. Waste Isolation Pilot Plant supplementary roof support system underground storage area, Panel 1, Room 1

    International Nuclear Information System (INIS)

    1991-10-01

    WIPP is designed to provide a full-scale facility to demonstrate the technical and operational principles for permanent isolation of defense-generated transuranic waste. It is also designed to provide a facility in which studies and experiments can be conducted. Bin Scale Tests are being planned as part of the WIPP Test Phase Performance Assessment Program described in the WIPP Test Phase Plan: Performance Assessment (DOE 1990 b). These Tests are anticipated to be conducted over a period of up to seven years. Room 1 of Panel 1 of the Underground Storage Area is to be used as the location of the Bin-Scale Tests to investigate the generation of gas from the waste that is proposed to be stored at the WIPP in the near future. The original design for the waste storage rooms in Panel 1 provided for a limited period of time during which to mine the openings and to emplace waste. Room 1 was initially mined to rough dimensions in 1986. Information obtained from the Site and Preliminary Design Validation (SPDV) program showed that the rooms would remain stable without ground support and that creep closure would not adversely affect equipment clearances during at least five years following excavation

  8. Exploration of Important Issues for the Safety of SFR 1 using Performance Assessment Calculations

    International Nuclear Information System (INIS)

    Maul, P.R.; Robinson, P.C.

    2002-06-01

    SKB has produced a revised safety case for the SFR 1 disposal facility for low and intermediate level radioactive wastes at Forsmark: project SAFE. This assessment includes a Performance Assessment (PA) for the long term post-closure safety of the facility. SKI has a responsibility to scrutinise SKB's safety case that is shared with SSI. Quintessa has undertaken a review of SKB's case for the long term safety of SFR 1 to assist SKI's evaluation of SAFE, and this is given in SKI-R--02-61, henceforth referred to as the Quintessa Review. The current report describes the independent PA calculations that provided an input to that review. Since 1999 SKI has been developing a PA capability for SFR 1 using the AMBER software. Two key features of the approach taken have been: To represent the whole system in a single model; and To allow the time-dependency of all key features, events and processes to be represented. These capabilities allow a better understanding of the key features of the system to be obtained for different future evolutions (scenarios). This report presents a summary of the work undertaken to provide SKI with a PA capability for SFR 1 and the calculations undertaken with it. Calculations have been undertaken for radionuclides transported in groundwater and gas, but not for direct intrusion by humans into the wastes. It should be emphasised that the purpose of the Performance Assessment calculations described in this report is not to provide an alternative assessment of potential radiological impacts to that produced by SKB. The aim is to use the models that have been developed to investigate the important features of the system and to help SKI scrutinise the case put to them by SKB. The PA calculations that have been undertaken are by no means comprehensive, and various issues could be investigated further if required. The key issues that have been identified can be summarised as follows: 1. The SFR 1 system has a number of different timescales that can

  9. Air quality management and planning system for Guangzhou. Report from workshop 1, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Larssen, Steinar

    1999-02-01

    The report is proceedings from Workshop no. 1, 1998 of the Sino-Norwegian co-operation project ''Guangzhou Air Quality Management and Planning System''. The project studies pollution emissions generally and from coal, vehicle and energy activities, dispersion modelling, monitoring, exposure, health damage assessment, material damage assessment, vegetation, control options, baseline scenario development, cost benefit analysis, pollution control management and policy instruments and air pollution forecasting. A forth workshop is planned. There are several reports from the various project activities.

  10. Nuclear energy system department annual report. April 1, 2000 - March 31, 2001

    International Nuclear Information System (INIS)

    Osugi, Toshitaka; Takase, Kazuyuki; Kunii, Katsuhiko

    2002-03-01

    This report summarizes the research and development activities in the Department of Nuclear Energy System during the fiscal year of 2000 (April 1, 2000 - March 31, 2001). The Department has been organized from April 1998. The main research activity is aimed to build the basis of the development of future nuclear energy systems. The research activities of the Department cover basic nuclear and atomic and molecular data evaluation, conceptual design of a reduced-moderation water reactor, reactor physics experiments and development of the reactor analysis codes, experiment and analysis of thermal-hydrodynamics, energy system analysis and assessment, development of advanced materials for a reactor, lifetime reliability assessment on structural material, development of advanced nuclear fuel, study of nuclear transmutation systems, design of a marine reactor and the research for a nuclear ship system. The maintenance and operation of reactor engineering facilities belonging to the Department are undertaken. The activities of the research committees to which the Department takes a role of secretariat are also summarized in this report. (author)

  11. 41 CFR 101-1.101 - Federal Property Management Regulations System.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Federal Property Management Regulations System. 101-1.101 Section 101-1.101 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1...

  12. Orion Exploration Flight Test-1 Post-Flight Navigation Performance Assessment Relative to the Best Estimated Trajectory

    Science.gov (United States)

    Gay, Robert S.; Holt, Greg N.; Zanetti, Renato

    2016-01-01

    This paper details the post-flight navigation performance assessment of the Orion Exploration Flight Test-1 (EFT-1). Results of each flight phase are presented: Ground Align, Ascent, Orbit, and Entry Descent and Landing. This study examines the on-board Kalman Filter uncertainty along with state deviations relative to the Best Estimated Trajectory (BET). Overall the results show that the Orion Navigation System performed as well or better than expected. Specifically, the Global Positioning System (GPS) measurement availability was significantly better than anticipated at high altitudes. In addition, attitude estimation via processing GPS measurements along with Inertial Measurement Unit (IMU) data performed very well and maintained good attitude throughout the mission.

  13. Occupational Analysis Products: Space Systems Operations - AFSC 1C6X1 (CD-ROM)

    National Research Council Canada - National Science Library

    Boerstler, Robert E

    2004-01-01

    ...: 1 CD-ROM; 4 3/4 in.; 30.4 MB. SYSTEMS DETAIL NOTE: ABSTRACT: The Space Systems Operations career ladder was surveyed to obtain current task and equipment data for use in evaluating current training programs...

  14. Real-world clinical applicability of pathogenicity predictors assessed on SERPINA1 mutations in alpha-1-antitrypsin deficiency.

    Science.gov (United States)

    Giacopuzzi, Edoardo; Laffranchi, Mattia; Berardelli, Romina; Ravasio, Viola; Ferrarotti, Ilaria; Gooptu, Bibek; Borsani, Giuseppe; Fra, Annamaria

    2018-06-07

    The growth of publicly available data informing upon genetic variations, mechanisms of disease and disease sub-phenotypes offers great potential for personalised medicine. Computational approaches are likely required to assess large numbers of novel genetic variants. However, the integration of genetic, structural and pathophysiological data still represents a challenge for computational predictions and their clinical use. We addressed these issues for alpha-1-antitrypsin deficiency, a disease mediated by mutations in the SERPINA1 gene encoding alpha-1-antitrypsin. We compiled a comprehensive database of SERPINA1 coding mutations and assigned them apparent pathological relevance based upon available data. 'Benign' and 'Pathogenic' mutations were used to assess performance of 31 pathogenicity predictors. Well-performing algorithms clustered the subset of variants known to be severely pathogenic with high scores. Eight new mutations identified in the ExAC database and achieving high scores were selected for characterisation in cell models and showed secretory deficiency and polymer formation, supporting the predictive power of our computational approach. The behaviour of the pathogenic new variants and consistent outliers were rationalised by considering the protein structural context and residue conservation. These findings highlight the potential of computational methods to provide meaningful predictions of the pathogenic significance of novel mutations and identify areas for further investigation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. 46 CFR 111.103-1 - Power ventilation systems except machinery space ventilation systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power ventilation systems except machinery space ventilation systems. 111.103-1 Section 111.103-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Power ventilation systems except machinery space ventilation systems. Each power ventilation system must...

  16. Central nervous system manifestations in pediatric patients with influenza A H1N1 infection during the 2009 pandemic.

    Science.gov (United States)

    Wilking, Ashley N; Elliott, Elizabeth; Garcia, Melissa N; Murray, Kristy O; Munoz, Flor M

    2014-09-01

    A novel H1N1 influenza A virus (A(H1N1)pdm09) particularly affected individuals central nervous system complications associated with pandemic influenza in the pediatric population. Retrospective review of patients with laboratory-confirmed influenza A(H1N1)pdm09 infection and central nervous system manifestations at Texas Children's Hospital between April 2009 and June 2010. Among 365 patients with influenza A(H1N1)pdm09, 32 (8.8%) had central nervous system manifestations at a median age of 4 years. Eight (25.0%) were previously healthy, and 12 (37.5%) had neurological pre-existing conditions. Of the 32 cases of influenza with neurological complications, seizure (n = 17; 53.1%) was the most common central nervous system manifestation, followed by encephalitis (n = 4; 12.5%), meningitis (n = 4; 12.5%), encephalopathy (n = 3; 9.4%), meningismus (n = 3; 9.4%), focal hemorrhagic brain lesions (n = 2; 6.3%), brain infarction (n = 1; 3.1%), and sensorineural hearing loss (n = 1; 3.1%). Two patients demonstrated two or more types of central nervous system complications. One patient had abnormal cerebrospinal fluid with pleocytosis. Almost two thirds of the children with central nervous system manifestations required intensive care unit admission and nearly half required mechanical ventilation. There were no deaths. Patients with pre-existing neurological conditions were at greater risk for central nervous system manifestations during pandemic influenza infection. Patients with central nervous system manifestations were more likely to experience severe illness, characterized by intensive care unit admission and mechanical ventilation, although overall outcomes were good. Influenza prevention in patients with underlying medical conditions, particularly those with neurological conditions, is important. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Diffusion and particle mobility in 1D system

    International Nuclear Information System (INIS)

    Borman, V.D.; Johansson, B.; Skorodumova, N.V.; Tronin, I.V.; Tronin, V.N.; Troyan, V.I.

    2006-01-01

    The transport properties of one-dimensional (1D) systems have been studied theoretically. Contradictory experimental results on molecular transport in quasi-1D systems, such as zeolite structures, when both diffusion transport acceleration and the existence of the diffusion mode with lower particle mobility (single-file diffusion ( 2 >∼t 1/2 )) have been reported, are consolidated in a consistent model. Transition from the single-file diffusion mode to an Einstein-like diffusion 2 >∼t with diffusion coefficient increasing with the density has been predicted to occur at large observation times

  18. The range of excursion of flexor tendons in Zone V: a comparison of active vs passive flexion mobilisation regimes.

    LENUS (Irish Health Repository)

    Panchal, J

    1997-10-01

    A number of early postoperative mobilisation regimes have been developed in an attempt to increase tendon excursion and gliding and thereby reduce formation of adhesions following repair of flexor tendons. Early active flexion mobilisation regimes are becoming more popular, and have replaced early passive flexion regimes in many centres. The aim of the present study was: (a) to determine the range of excursion of flexor tendons in Zone V, and (b) to compare the excursion ranges between active (Belfast) and passive (modified Duran) flexion mobilisation regimes postoperatively. This was done (a) in two cadavers, and (b) in two patients intraoperatively, and postoperatively at 10 days, 3 weeks and 6 weeks. With passive flexion, the mean tendon excursion in Zone V in cadavers was 1 mm for flexor digitorum superficialis (FDS), flexor digitorum profundus (FDP) and flexor pollicis longus (FPL) tendons respectively. With simulated active flexion, the mean tendon excursion was 14 mm, 10 mm and 11 mm respectively. The mean tendon excursion in clinical cases intraoperatively following passive flexion was 2 mm for FDS, FDP and FPL respectively; following simulated active flexion it was 10 mm, 11 mm and 11 mm for FDS, FDP and FPL respectively. On the tenth day following repair, the mean excursions of FDS, FDP and FPL were 1 mm, 4 mm and 4 mm on passive flexion as compared to 3 mm, 10 mm and 12 mm on active flexion respectively. Three weeks postoperatively, the mean excursions of FDS, FDP and FPL tendons were 1 mm, 2 mm and 1 mm on passive flexion as compared to 5 mm, 15 mm on active flexion respectively. Six weeks postoperatively, the mean excursions of FDS, FDP and FPL tendons were 9 mm, 7 mm and 4 mm on passive flexion as compared to 12 mm, 33 mm and 20 mm on active flexion respectively. These results demonstrate an increased excursion of repaired flexor tendons in Zone V following an active flexion mobilisation regime as compared to a passive flexion mobilisation regime.

  19. Design and producing of fine-group cross section library HENDL3.0/FG for subcritical system

    International Nuclear Information System (INIS)

    Zou, J.; Zeng, Q.; Xu, D.; Hu, L.; Long, P.

    2012-01-01

    To improve the accuracy of the neutron analyses for subcritical system with thermal fission blanket, a coupled neutron and photon (315 n + 42γ) fine-group cross section library HENDL3.0/FG based on ENDF/B-VII, JEFF3.1 and JENDL3.3 was produced by FDS team. In order to test the availability and reliability of the HENDL3.0/FG data library, shielding and critical safety benchmarks were performed with VisualBUS code. The testing results indicated that the discrepancy between calculation and experimental values of nuclear parameters fell in a reasonable range. It showed that the nuclear data library had accuracy and availability. (authors)

  20. User's guide for PRISM (Plant Risk Status Information Management System) Arkansas Nuclear One-Unit 1: Volume 1, Program for inspectors

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, D.J.; Guthrie, V.H.; Kirchner, J.R.; Kirkman, J.Q.; Paula, H.M.; Ellison, B.C.; Dycus, F.M.; Farquharson, J.A.; Flanagan, G.F.

    1988-03-01

    This user's guide is a two-volume document designed to teach NRC inspectors and NRC regulators how to access probabilistic risk assessment information from the two Plant Risk Status Information Management System (PRISIM) programs developed for Arkansas Nuclear One -- Unit One (ANO-1). This document, Volume 1, describes how the PRA information available in Version 1.0 of PRISIM is useful for planning inspections. Using PRISIM, inspectors can quickly access PRA information and use that information to update risk analysis results, reflecting a plant's status at any particular time. Both volumes are stand-alone documents, and each volume presents several sample computer sessions designed to lead the user through a variety of PRISIM applications used to obtain PRA-related information for monitoring and controlling plant risk.

  1. User's manual for the G.T.M.-1 computer code

    International Nuclear Information System (INIS)

    Prado-Herrero, P.

    1992-01-01

    This document describes the GTM-1 ( Geosphere Transport Model, release-1) computer code and is intended to provide the reader with enough detailed information in order to use the code. GTM-1 was developed for the assessment of radionuclide migration by the ground water through geologic deposits whose properties can change along the pathway.GTM-1 solves the transport equation by the finite differences method ( Crank-Nicolson scheme ). It was developped for specific use within Probabilistic System Assessment (PSA) Monte Carlo Method codes; in this context the first application of GTM-1 was within the LISA (Long Term Isolation System Assessment) code. GTM-1 is also available as an independent model, which includes various submodels simulating a multi-barrier disposal system. The code has been tested with the PSACOIN ( Probabilistic System Assessment Codes intercomparison) benchmarks exercises from PSAC User Group (OECD/NEA). 10 refs., 6 Annex., 2 tabs

  2. VEGAS-SSS. II. Comparing the globular cluster systems in NGC 3115 and NGC 1399 using VEGAS and FDS survey data. The quest for a common genetic heritage of globular cluster systems

    Science.gov (United States)

    Cantiello, Michele; D'Abrusco, Raffaele; Spavone, Marilena; Paolillo, Maurizio; Capaccioli, Massimo; Limatola, Luca; Grado, Aniello; Iodice, Enrica; Raimondo, Gabriella; Napolitano, Nicola; Blakeslee, John P.; Brocato, Enzo; Forbes, Duncan A.; Hilker, Michael; Mieske, Steffen; Peletier, Reynier; van de Ven, Glenn; Schipani, Pietro

    2018-04-01

    We analyze the globular cluster (GC) systems in two very different galaxies, NGC 3115 and NGC 1399. With the papers of this series, we aim at highlighting common and different properties in the GC systems in galaxies covering a wide range of parameter space. We compare the GCs in NGC 3115 and NGC 1399 as derived from the analysis of one square degree u-, g-, and i-band images taken with the VST telescope as part of the VST early-type galaxy survey (VEGAS) and Fornax deep survey (FDS). We selected GC candidates using as reference the morpho-photometric and color properties of confirmed GCs. The surface density maps of GCs in NGC 3115 reveal a morphology similar to the light profile of field stars; the same is true when blue and red GCs are taken separately. The GC maps for NGC 1399 are richer in structure and confirm the existence of an intra-cluster GC component. We confirm the presence of a spatial offset in the NGC 1399 GC centroid and find that the centroid of the GCs for NGC 3115 coincides well with the galaxy center. Both GC systems show unambiguous color bimodality in (g - i) and (u - i); the color-color relations of the two GC systems are slightly different with NGC 3115 appearing more linear than NGC 1399. The azimuthal average of the radial density profiles in both galaxies reveals a larger spatial extent for the total GCs population with respect to the galaxy surface brightness profile. For both galaxies, the red GCs have radial density profiles compatible with the galaxy light profile, while the radial profiles for blue GCs are shallower. As for the specific frequency of GCs, SN, we find it is a factor of two higher in NGC 1399 than for NGC 3115; this is mainly the result of extra blue GCs. By inspecting the radial behavior of the specific frequency, SN(

  3. Vacuum system of SST-1 Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Ziauddin, E-mail: ziauddin@ipr.res.in [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382 428 (India); Pathan, Firozkhan; George, Siju; Semwal, Pratibha; Dhanani, Kalpesh; Paravastu, Yuvakiran; Thankey, Prashant; Ramesh, Gattu; Himabindu, Manthena; Pradhan, Subrata [Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382 428 (India)

    2013-10-15

    Highlights: ► Air leaks developed during ongoing SST-1 cooldown campaign were detected online using RGA. ► The presence of N{sub 2} and O{sub 2} gases with the ratio of their partial pressures with ∼3.81:1 confirmed the air leaks. ► Baking of SST-1 was done efficiently by flowing hot N{sub 2} gas in C-channels welded on inner surfaces without any problem. ► In-house fabricated demountable bull nose couplers were demonstrated for high temperature and pressure applications. ► Cryopumping effect was observed when liquid helium cooled superconducting magnets reached below 63 K. -- Abstract: Vacuum chambers of Steady State Superconducting (SST-1) Tokamak comprises of the vacuum vessel and the cryostat. The plasma will be confined inside the vacuum vessel while the cryostat houses the superconducting magnet systems (TF and PF coils), LN{sub 2} cooled thermal shields and hydraulics for these circuits. The vacuum vessel is an ultra-high (UHV) vacuum chamber while the cryostat is a high-vacuum (HV) chamber. In order to achieve UHV inside the vacuum vessel, it would be baked at 150 °C for longer duration. For this purpose, U-shaped baking channels are welded inside the vacuum vessel. The baking will be carried out by flowing hot nitrogen gas through these channels at 250 °C at 4.5 bar gauge pressure. During plasma operation, the pressure inside the vacuum vessel will be raised between 1.0 × 10{sup −4} mbar and 1.0 × 10{sup −5} mbar using piezoelectric valves and control system. An ultimate pressure of 4.78 × 10{sup −6} mbar is achieved inside the vacuum vessel after 100 h of pumping. The limitation is due to the development of few leaks of the order of 10{sup −5} mbar l/s at the critical locations of the vacuum vessel during baking which was confirmed with the presence of nitrogen gas and oxygen gas with the ratio of ∼3.81:1 indicating air leak. Similarly an ultimate vacuum of 2.24 × 10{sup −5} mbar is achieved inside the cryostat. Baking of the

  4. The embodied embedded character of system 1 processing.

    Science.gov (United States)

    Bellini-Leite, Samuel de Castro

    2013-01-01

    In the last thirty years, a relatively large group of cognitive scientists have begun characterising the mind in terms of two distinct, relatively autonomous systems. To account for paradoxes in empirical results of studies mainly on reasoning, Dual Process Theories were developed. Such Dual Process Theories generally agree that System 1 is rapid, automatic, parallel, and heuristic-based and System 2 is slow, capacity-demanding, sequential, and related to consciousness. While System 2 can still be decently understood from a traditional cognitivist approach, I will argue that it is essential for System 1 processing to be comprehended in an Embodied Embedded approach to Cognition.

  5. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP.

  6. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    International Nuclear Information System (INIS)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP

  7. Soil and Terrain Database for Upper Tana River Catchment (version 1.1) - scale 1:250,000 (SOTER_UT_v1.1)

    NARCIS (Netherlands)

    Dijkshoorn, J.A.; Macharia, P.; Kempen, B.

    2014-01-01

    The Soil and Terrain database for the Upper Tana River Catchment (version 1.1) (SOTER_UT_v1.1) at scale 1:250,000 was compiled to support the Green Water Credits (GWC) programme by creating a primary SOTER dataset for a hydrology assessment of the basin. The Kenya Soil Survey of the Kenya

  8. Preliminary design of GDT-based 14 MeV neutron source

    International Nuclear Information System (INIS)

    Du Hongfei; Chen Dehong; Wang Hui; Wang Fuqiong; Jiang Jieqiong; Wu Yican; Chen Yiping

    2012-01-01

    To meet the need of D-T fusion neutron source for fusion material testing, design goals were presented in this paper according to the international requirements of neutron source for fusion material testing. A preliminary design scheme of GDT-based 14 MeV neutron source was proposed, and a physics model of the neutron source was built based on progress of GDT experiments. Two preliminary design schemes (i. e. FDS-GDT1, FDS-GDT2) were designed; among which FDS-GDT2 can be used for fusion material testing with neutron first wall loading of 2 MW/m 2 . (authors)

  9. A 90 day safety assessment of genetically modified rice expressing Cry1Ab/1Ac protein using an aquatic animal model.

    Science.gov (United States)

    Zhu, Hao-Jun; Chen, Yi; Li, Yun-He; Wang, Jia-Mei; Ding, Jia-Tong; Chen, Xiu-Ping; Peng, Yu-Fa

    2015-04-15

    In fields of transgenic Bt rice, frogs are exposed to Bt proteins through consumption of both target and nontarget insects. In the present study, we assessed the risk posed by transgenic rice expressing a Cry1Ab/1Ac fusion protein (Huahui 1, HH1) on the development of Xenopus laevis. For 90 days, froglets were fed a diet with 30% HH1 rice, 30% parental rice (Minghui 63, MH63), or no rice as a control. Body weight and length were measured every 15 days. After sacrificing the froglets, we performed a range of biological, clinical, and pathological assessments. No significant differences were found in body weight (on day 90: 27.7 ± 2.17, 27.4 ± 2.40, and 27.9 ± 1.67 g for HH1, MH63, and control, respectively), body length (on day 90: 60.2 ± 1.55, 59.3 ± 2.33, and 59.7 ± 1.64 mm for HH1, MH63, and control, respectively), animal behavior, organ weight, liver and kidney function, or the microstructure of some tissues between the froglets fed on the HH1-containing diet and those fed on the MH63-containing or control diets. This indicates that frog development was not adversely affected by dietary intake of Cry1Ab/1Ac protein.

  10. Genetic polymorphism of interleukin-1A (IL-1A), IL-1B, and IL-1 receptor antagonist (IL-1RN) and prostate cancer risk.

    Science.gov (United States)

    Xu, Hua; Ding, Qiang; Jiang, Hao-Wen

    2014-01-01

    We aimed to investigate the associations between polymorphisms of interleukin-1A (IL-1A), IL-1B, and IL-1 receptor antagonist (IL-1RN) and prostate cancer (PCa) risk. A comprehensive search for articles of MEDLINE and EMBASE databases and bibliographies of retrieved articles published up to August 3, 2014 was performed. Methodological quality assessment of the trials was based on a standard quality scoring system. The meta-analysis was performed using STATA 12.0. We included 9 studies (1 study for IL-1A, 5 studies for IL-1B, and 3 studies for IL-1RN), and significant association was found between polymorphisms of IL-1B-511 (rs16944) as well as IL-1B-31 (rs1143627) and PCa risk. IL-1B-511 (rs16944) polymorphism was significantly associated with PCa risk in homozygote and recessive models, as well as allele contrast (TT vs CC: OR, 0.74; 95%CI, 0.58-0.94; P=0.012; TT vs TC+CC; OR, 0.79; 95%CI, 0.63-0.98; P=0.033; T vs C: OR, 0.86; 95%CI, 0.77-0.96; P=0.008). The association between IL-1B-31 (rs1143627) polymorphism and PCa risk was weakly significant under a heterozygote model (OR, 1.35; 95%CI, 1.00-1.80; P=0.047). Sequence variants in IL-1B-511 (rs16944) and IL-1B-31 (rs1143627) are significantly associated with PCa risk, which provides additional novel evidence that proinflammatory cytokines and inflammation play an important role in the etiology of PCa.

  11. Dog Erythrocyte Antigen 1 (DEA 1): Mode of Inheritance and Initial Characterization

    Science.gov (United States)

    Polak, Klaudia; Acierno, Michelle; Raj, Karthik; Mizukami, Keijiro; Siegel, Don L.; Giger, Urs

    2015-01-01

    Background The Dog Erythrocyte Antigen (DEA) 1 blood group system remains poorly defined. Objectives The purpose of the study was to determine the DEA 1 mode of inheritance and to characterize the DEA 1 antigen and alloantibodies. Animals Canine research colony families, clinic canine patients, and DEA 1.2+ blood bank dogs were studied. Methods Canine blood was typed by flow cytometry and immunochromatographic strips using anti-DEA 1 monoclonal antibodies. Gel column experiments with polyclonal and immunoblotting with monoclonal anti-DEA 1 antibodies were performed to analyze select samples. Cross-reactivity of human typing reagents against canine RBCs and one monoclonal anti-DEA 1 antibody against human RBC panels was assessed. Results Typing of 12 families comprising 144 dogs indicated an autosomal dominant inheritance with ≥4 alleles: DEA 1− (0) and DEA 1+ weak (1+), intermediate (2+) and strong (3+ and 4+). Samples from 6 dogs previously typed as DEA 1.2+ were typed as DEA 1+ or DEA 1− using monoclonal antibodies. Human typing reagents produced varied reactions in tube agglutination experiments against DEA 1+ and DEA 1− RBCs. Polypeptide bands were not detected on immunoblots using a monoclonal anti-DEA 1 antibody, therefore the anti-DEA 1 antibody may be specific for conformational epitopes lost during denaturation. Conclusions The autosomal dominant inheritance of DEA 1 with ≥4 alleles indicates a complex blood group system; the antigenicity of each DEA 1+ type will need to be determined. The biochemical nature of the DEA 1 antigen(s) appears different from human blood group systems tested. PMID:26291052

  12. Balance of plant modeling in TRAC-BD1/MOD1

    International Nuclear Information System (INIS)

    Weaver, W.L.; Giles, M.M.; Mohr, C.M.

    1983-01-01

    The mission of the TRAC-BD1/MOD1 code is to provide a best-estimate analysis capability for Boiling Water Reactor systems and related experimental facilities for the full range of accidents from large and small break Loss-of-Coolant accidents to operational transients including anticipated transients without scram (ATWS), for which point reactor kinetics is adequate (as a first approximation). Recent model developments allow a complete reactor system including the containment and the balance of plant to be modeled. This paper describes the balance of plant models and presents the results of a simulation of a loss-of-feedwater heater transients which was used to assess the performance of the balance of plant models

  13. Development and methodology of level 1 probability safety assessment at PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Maskin, Mazleha; Tom, Phongsakorn Prak; Lanyau, Tonny Anak; Saad, Mohamad Fauzi; Ismail, Ahmad Razali; Abu, Mohamad Puad Haji; Brayon, Fedrick Charlie Matthew; Mohamed, Faizal

    2014-01-01

    As a consequence of the accident at the Fukushima Dai-ichi Nuclear Power Plant in Japan, the safety aspects of the one and only research reactor (31 years old) in Malaysia need be reviewed. Based on this decision, Malaysian Nuclear Agency in collaboration with Atomic Energy Licensing Board and Universiti Kebangsaan Malaysia develop a Level-1 Probability Safety Assessment on this research reactor. This work is aimed to evaluate the potential risks of incidents in RTP and at the same time to identify internal and external hazard that may cause any extreme initiating events. This report documents the methodology in developing a Level 1 PSA performed for the RTP as a complementary approach to deterministic safety analysis both in neutronics and thermal hydraulics. This Level-1 PSA work has been performed according to the procedures suggested in relevant IAEA publications and at the same time numbers of procedures has been developed as part of an Integrated Management System programme implemented in Nuclear Malaysia

  14. Development and methodology of level 1 probability safety assessment at PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Mazleha Maskin; Phongsakorn, P.T.; Tonny, A.L.; Fedrick, C.M.B.; Faizal Mohamed; Mohamad Fauzi Saad; Ahmad Razali Ismail; Mohamad Puad Haji Abu

    2013-01-01

    Full-text: As a consequence of the accident at the Fukushima Dai-ichi Nuclear Power Plant in Japan, the safety aspects of the one and only research reactor (31 years old) in Malaysia need be reviewed. Based on this decision, Malaysian Nuclear Agency in collaboration with Atomic Energy Licensing Board and Universiti Kebangsaan Malaysia develop a Level-1 Probability Safety Assessment on this research reactor. This work is aimed to evaluate the potential risks of incidents in RTP and at the same time to identify internal and external hazard that may cause any extreme initiating events. This report documents the methodology in developing a Level 1 PSA performed for the RTP as a complementary approach to deterministic safety analysis both in neutronics and thermal hydraulics. This Level-1 PSA work has been performed according to the procedures suggested in relevant IAEA publications and at the same time numbers of procedures has been developed as part of an Integrated Management System programme implemented in Nuclear Malaysia. (author)

  15. The Influenza A(H1N1)v Pandemic : An Exploratory System Dynamics Approach

    NARCIS (Netherlands)

    Pruyt, E.; Hamarat, C.

    2010-01-01

    This paper presents a small exploratory System Dynamics model related to the dynamics of the 2009 flu pandemic, also known as the Mexican flu, swine flu, or A(H1N1)v. The model was developed in May 2009 in order to quickly foster understanding about the possible dynamics of this new flu variant and

  16. Symmetric coupling of four spin-1/2 systems

    Science.gov (United States)

    Suzuki, Jun; Englert, Berthold-Georg

    2012-06-01

    We address the non-binary coupling of identical angular momenta based upon the representation theory for the symmetric group. A correspondence is pointed out between the complete set of commuting operators and the reference-frame-free subsystems. We provide a detailed analysis of the coupling of three and four spin-1/2 systems and discuss a symmetric coupling of four spin-1/2 systems.

  17. Plasma YKL-40 and CHI3L1 in systemic inflammation and sepsis—Experience from two prospective cohorts

    DEFF Research Database (Denmark)

    Kornblit, Brian; Hellemann, Dorthe; Munthe-Fog, Lea

    2013-01-01

    YKL-40, derived from the CHI3L1 gene, has been associated with outcome of infectious and inflammatory diseases. We hypothesized that plasma YKL-40 concentrations and CHI3L1 genotype could be used as prognostic biomarkers in the assessment of systemic inflammatory response syndrome (SIRS) and sepsis....... The objective of the study was to assess the prognostic value of plasma YKL-40 and CHI3L1 genotype in patients with SIRS and sepsis. Plasma YKL-40 and CHI3L1 genotype (rs4950928) were analyzed at time of admission to intensive care units (ICU), in two prospective cohorts of consecutive SIRS patients (cohort 1...

  18. On Positive Solutions for the Rational Difference Equation Systems x n+1 = A/x n y n (2), and y n+1 = By n /x n-1 y n-1.

    Science.gov (United States)

    Ma, Hui-Li; Feng, Hui

    2014-01-01

    Our aim in this paper is to investigate the behavior of positive solutions for the following systems of rational difference equations: x n+1 = A/x n y n (2), and y n+1 = By n /x n-1 y n-1, n = 0,1,…, where x -1, x 0, y -1, and y 0 are positive real numbers and A and B are positive constants.

  19. Independent System Calibration of Sentinel-1B

    Directory of Open Access Journals (Sweden)

    Marco Schwerdt

    2017-05-01

    Full Text Available Sentinel-1B is the second of two C-Band Synthetic Aperture Radar (SAR satellites of the Sentinel-1 mission, launched in April 2016—two years after the launch of the first satellite, Sentinel-1A. In addition to the commissioning of Sentinel-1B executed by the European Space Agency (ESA, an independent system calibration was performed by the German Aerospace Center (DLR on behalf of ESA. Based on an efficient calibration strategy and the different calibration procedures already developed and applied for Sentinel-1A, extensive measurement campaigns were executed by initializing and aligning DLR’s reference targets deployed on the ground. This paper describes the different activities performed by DLR during the Sentinel-1B commissioning phase and presents the results derived from the analysis and the evaluation of a multitude of data takes and measurements.

  20. Guide for Regional Integrated Assessments: Handbook of Methods and Procedures, Version 5.1. Appendix 1

    Science.gov (United States)

    Rosenzweig, Cynthia E.; Jones, James W.; Hatfield, Jerry; Antle, John; Ruane, Alex; Boote, Ken; Thorburn, Peter; Valdivia, Roberto; Porter, Cheryl; Janssen, Sander; hide

    2015-01-01

    The purpose of this handbook is to describe recommended methods for a trans-disciplinary, systems-based approach for regional-scale (local to national scale) integrated assessment of agricultural systems under future climate, bio-physical and socio-economic conditions. An earlier version of this Handbook was developed and used by several AgMIP Regional Research Teams (RRTs) in Sub-Saharan Africa (SSA) and South Asia (SA)(AgMIP handbook version 4.2, www.agmip.org/regional-integrated-assessments-handbook/). In contrast to the earlier version, which was written specifically to guide a consistent set of integrated assessments across SSA and SA, this version is intended to be more generic such that the methods can be applied to any region globally. These assessments are the regional manifestation of research activities described by AgMIP in its online protocols document (available at www.agmip.org). AgMIP Protocols were created to guide climate, crop modeling, economics, and information technology components of its projects.

  1. Immunohistochemical assessment of NY-ESO-1 expression in esophageal adenocarcinoma resection specimens.

    Science.gov (United States)

    Hayes, Stephen J; Hng, Keng Ngee; Clark, Peter; Thistlethwaite, Fiona; Hawkins, Robert E; Ang, Yeng

    2014-04-14

    To assess NY-ESO-1 expression in a cohort of esophageal adenocarcinomas. A retrospective search of our tissue archive for esophageal resection specimens containing esophageal adenocarcinoma was performed, for cases which had previously been reported for diagnostic purposes, using the systematised nomenclature of human and veterinary medicine coding system. Original haematoxylin and eosin stained sections were reviewed, using light microscopy, to confirm classification and tumour differentiation. A total of 27 adenocarcinoma resection specimens were then assessed using immunohistochemistry for NY-ESO-1 expression: 4 well differentiated, 14 moderately differentiated, 4 moderate-poorly differentiated, and 5 poorly differentiated. Four out of a total of 27 cases of esophageal adenocarcinoma examined (15%) displayed diffuse cytoplasmic and nuclear expression for NY-ESO-1. They displayed a heterogeneous and mosaic-type pattern of diffuse staining. Diffuse cytoplasmic staining was not identified in any of these structures: stroma, normal squamous epithelium, normal submucosal gland and duct, Barrett's esophagus (goblet cell), Barrett's esophagus (non-goblet cell) and high grade glandular dysplasia. All adenocarcinomas showed an unexpected dot-type pattern of staining at nuclear, paranuclear and cytoplasmic locations. Similar dot-type staining, with varying frequency and size of dots, was observed on examination of Barrett's metaplasia, esophageal submucosal gland acini and the large bowel negative control, predominantly at the crypt base. Furthermore, a prominent pattern of apical (luminal) cytoplasmic dot-type staining was observed in some cases of Barrett's metaplasia and also adenocarcinoma. A further morphological finding of interest was noted on examination of haematoxylin and eosin stained sections, as aggregates of lymphocytes were consistently noted to surround submucosal glands. We have demonstrated for the first time NY-ESO-1 expression by esophageal

  2. BOOK REVIEW: Assessing Sc1 for GCSE

    Science.gov (United States)

    Reynolds, H.

    2000-01-01

    It is well known that investigations that `fit' the National Curriculum or examination board criteria are few in number. The fair testing emphasis means that pupils all over the country are finding out what affects the rate of a chemical reaction, the rate of photosynthesis or, in the case of Physics, the resistance of a wire. This book focuses on nine of the most common Sc1 investigations and how to prepare for them, manage and assess them. The author, a GCSE examiner, has turned his expertise into a handbook for improving Sc1 performance in the classroom. He has produced a book that would be extremely useful to both newly qualified teachers and experienced teachers. The first aim of the book, however, is to explain the requirements of Sc1. This is done comprehensively with examples of what the jargon means in practice. By breaking down the elements of planning, obtaining evidence, analysing evidence and evaluating, it is easy to see the subtleties of the mark descriptors. At first glance there seems to be little difference between the type of scientific knowledge needed for planning at level 6 and level 8. However, the level 8 statement specifies `detailed' scientific knowledge and understanding, which would mean a student should use equations from physics or symbolic chemical equations to support their arguments. One of the most useful sections in the book details the marking problems that can arise with some investigations. For example, in an investigation into electromagnets it is difficult for students to provide sufficient relevant scientific theory to satisfy the requirements of planning at level 6. One of the problems with Sc1 is that certain requirements, such as graph plotting, are difficult for many students. This book provides exercises that can be given to students to improve those skills. Each of the nine investigations is covered in great detail. Each investigation begins with an introduction detailing the rationale for choosing it, whether students

  3. H1DS: A new web-based data access system

    Energy Technology Data Exchange (ETDEWEB)

    Pretty, D.G., E-mail: david.pretty@anu.edu.au; Blackwell, B.D.

    2014-05-15

    Highlights: • We present H1DS, a new RESTful web service for accessing fusion data. • We examine the scalability and extensibility of H1DS. • We present a fast and user friendly web browser client for the H1DS web service. • A summary relational database is presented as an application of the H1DS API. - Abstract: A new data access system, H1DS, has been developed and deployed for the H-1 Heliac at the Australian Plasma Fusion Research Facility. The data system provides access to fusion data via a RESTful web service. With the URL acting as the API to the data system, H1DS provides a scalable and extensible framework which is intuitive to new users, and allows access from any internet connected device. The H1DS framework, originally designed to work with MDSplus, has a modular design which can be extended to provide access to alternative data storage systems.

  4. H1DS: A new web-based data access system

    International Nuclear Information System (INIS)

    Pretty, D.G.; Blackwell, B.D.

    2014-01-01

    Highlights: • We present H1DS, a new RESTful web service for accessing fusion data. • We examine the scalability and extensibility of H1DS. • We present a fast and user friendly web browser client for the H1DS web service. • A summary relational database is presented as an application of the H1DS API. - Abstract: A new data access system, H1DS, has been developed and deployed for the H-1 Heliac at the Australian Plasma Fusion Research Facility. The data system provides access to fusion data via a RESTful web service. With the URL acting as the API to the data system, H1DS provides a scalable and extensible framework which is intuitive to new users, and allows access from any internet connected device. The H1DS framework, originally designed to work with MDSplus, has a modular design which can be extended to provide access to alternative data storage systems

  5. PROBING TRAPPIST-1-LIKE SYSTEMS WITH K2

    Energy Technology Data Exchange (ETDEWEB)

    Demory, Brice-Olivier; Queloz, Didier; Gillen, Ed [Astrophysics Group, Cavendish Laboratory, J.J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Alibert, Yann [Physikalisches Institut and Center for Space and Habitability, Universität Bern, 3012 Bern (Switzerland); Gillon, Michael, E-mail: bod21@cam.ac.uk [Institut d’Astrophysique et de Geophysique, Universite de Liege, Allee du 6 Aout 17, Bat. B5C, B-4000 Liege (Belgium)

    2016-07-10

    The search for small planets orbiting late M dwarfs holds the promise of detecting Earth-size planets for which their atmospheres could be characterized within the next decade. The recent discovery of TRAPPIST-1 entertains hope that these systems are common around hosts located at the bottom of the main sequence. In this Letter, we investigate the ability of the repurposed Kepler mission ( K2 ) to probe planetary systems similar to TRAPPIST-1. We perform a consistent data analysis of 189 spectroscopically confirmed M5.5 to M9 late M dwarfs from Campaigns 1–6 to search for planet candidates and inject transit signals with properties matching TRAPPIST-1b and c. We find no transiting planet candidates across our K2 sample. Our injection tests show that K2 is able to recover both TRAPPIST-1 planets for 10% of the sample only, mainly because of the inefficient throughput at red wavelengths resulting in Poisson-limited performance for these targets. Increasing injected planetary radii to match GJ 1214b’s size yields a recovery rate of 70%. The strength of K2 is its ability to probe a large number of cool hosts across the different campaigns, out of which the recovery rate of 10% may turn into bona fide detections of TRAPPIST-1-like systems within the next two years.

  6. The S-1 Spheromak Control System

    International Nuclear Information System (INIS)

    Mathe, P.; Mika, R.; Oliaro, G.

    1983-01-01

    The use of a CAMAC based DEC LSI-11/23 microcomputer to perform all control functions for the S-1 Spheromak is described. The system monitors and controls the three coil systems, Toroidal, Poloidal, and Equilibrium field coils and their associated power sources, the water cooling system, the personnel and machine safety system, the machine and diagnostic timing system and the control room display and operator interface. Future requirements include control of the vacuum system, the gas injection system and interface to the PPPL Data Acquisition System DEC10. The computer is connected to five remotely located CAMAC crates by a fiber-optic serial highway operating at five megahertz. These crates contain interface modules required to control the S-1 experiment. These modules include: D/A and A/D converters, fast transient digitizers, timing modules, temperature sensing modules, CRT alphanumeric display drivers, watchdog timers, and relay and TTL parallel I/O ports. The computer itself resides in crate number0 and consists of an LSI-11/23 with hardware floating post processor, memory management, 256K bytes of memory, four RS-232 serial ports and a 30 megabyte hard disk with a one megabyte floppy disk backup. The majority of software is written in FORTRAN with a few speed critical programs written in PDP-11 MACRO assembly language. The software simulates a sequential state machine which allows easily changeable logic since all logic is represented by standard Boolean Fortran statements. The RSX-11/m operating system allows multiple tasks to be active simultaneously. This provides computing time for operator interactions, editing of critical machine parameters, data analysis and transmission of data to other computers while still maintaining the scan activity which constantly monitors machine parameters

  7. Efficient cell culture system for hepatitis C virus genotype 1a and 1b

    DEFF Research Database (Denmark)

    2013-01-01

    isolate in generating efficient cell culture systems for other isolates by transfer of mutations across isolates, subtypes or major genotypes. Furthermore neutralization studies showed that viruses of e.g. genotype 1 were efficiently neutralized by genotype Ia, 4a and 5a serum, an effect that could......The present inventors developed hepatitis C virus 1a/2a and 1b/2a intergenotypic recombinants in which the JFH1 structural genes (Core, E1 and E2), p7 and NS2 were replaced by the corresponding genes of the genotype Ia reference strain H77C or TN or the corresponding genes of the genotype Ib...... reference strain J4. Sequence analysis of recovered 1a/2a and 1b/2a recombinants from 2 serial passages and subsequent reverse genetic studies revealed adaptive mutations in e.g. p7, NS2 and/or NS3. In addition, the inventors demonstrate the possibility of using adaptive mutations identified for one HCV...

  8. Using Potentiometric Free Drug Sensors to Determine the Free Concentration of Ionizable Drugs in Colloidal Systems

    DEFF Research Database (Denmark)

    Tran, Thuy; Chakraborty, Anjan; Xi, Xi

    2018-01-01

    The present study investigates the use of free drug sensors (FDS) to measure free ionized drug concentrations in colloidal systems, including micellar solutions, emulsions, and lipid formulations during in vitro lipolysis. Diphenhydramine hydrochloride (DPH) and loperamide hydrochloride (LOP) wer...

  9. Development and validation of a house finch interleukin-1β (HfIL-1β) ELISA system.

    Science.gov (United States)

    Kim, Sungwon; Park, Myeongseon; Leon, Ariel E; Adelman, James S; Hawley, Dana M; Dalloul, Rami A

    2017-08-30

    A unique clade of the bacterium Mycoplasma gallisepticum (MG), which causes chronic respiratory disease in poultry, has resulted in annual epidemics of conjunctivitis in North American house finches since the 1990s. Currently, few immunological tools have been validated for this songbird species. Interleukin-1β (IL-1β) is a prototypic multifunctional cytokine and can affect almost every cell type during Mycoplasma infection. The overall goal of this study was to develop and validate a direct ELISA assay for house finch IL-1β (HfIL-1β) using a cross-reactive chicken antibody. A direct ELISA approach was used to develop this system using two different coating methods, carbonate and dehydration. In both methods, antigens (recombinant HfIL-1b or house finch plasma) were serially diluted in carbonate-bicarbonate coating buffer and either incubated at 4 °C overnight or at 60 °C on a heating block for 2 hr. To generate the standard curve, rHfIL-1b protein was serially diluted at 0, 3, 6, 9, 12, 15, 18, 21, and 24 ng/mL. Following blocking and washing, anti-chicken IL-1b polyclonal antibody was added, plates were later incubated with detecting antibodies, and reactions developed with tetramethylbenzidine solution. A commercially available anti-chicken IL-1β (ChIL-1β) polyclonal antibody (pAb) cross-reacted with house finch plasma IL-1β as well as bacterially expressed recombinant house finch IL-1β (rHfIL-1β) in immunoblotting assays. In a direct ELISA system, rHfIL-1β could not be detected by an anti-ChIL-1β pAb when the antigen was coated with carbonate-bicarbonate buffer at 4°C overnight. However, rHfIL-1β was detected by the anti-ChIL-1β pAb when the antigen was coated using a dehydration method by heat (60°C). Using the developed direct ELISA for HfIL-1β with commercial anti-ChIL-1β pAb, we were able to measure plasma IL-1β levels from house finches. Based on high amino acid sequence homology, we hypothesized and demonstrated cross-reactivity of

  10. The System 80+ Standard Plant design control document. Volume 1

    International Nuclear Information System (INIS)

    1997-01-01

    This Design Control Document (DCD) is a repository of information comprising the System 80+trademark Standard Plant Design. The DCD also provides that design-related information to be incorporated by reference in the design certification rule for the System 80+ Standard Plant Design. Applicants for a combined license pursuant to 10 CFR 52 must ensure that the final Design Certification Rule and the associated Statements of Consideration are used when making all licensing decisions relevant to the System 80+ Standard Plant Design. The Design Control Document contains the DCD introduction, The Certified Design Material (CDM) [i.e., ''Tier 1''] and the Approved Design Material (ADM) [i.e., ''Tier 2''] for the System 80+ Standard Plant Design. The CDM includes the following sections: (1) Introductory material; (2) Certified Design Material for System 80+ systems and structures; (3) Certified Design Material for non-system-based aspects of the System 80+ Certified design; (4) Interface requirements; and (5) Site parameters. The ADM, to the extent applicable for the System 80+ Standard Plant Design, includes: (1) the information required for the final safety analysis report under 20 CFR 50.34; (2) other relevant information required by 10 CFR 52.47; and (3) emergency operations guidelines. This volume covers the DCD introduction and contains sections 1 and parts 1--7 of section 2 of the CDM. Parts 1--7 included the following: (2.1) Design of SSC; (2.2) Reactor; (2.3) RCS and connected systems; (2.4) Engineered Safety Features; (2.5) Instrumentation and Control; (2.6) Electric Power; and (2.7) Auxiliary Systems

  11. Independent Orbiter Assessment (IOA): Assessment of the orbital maneuvering system FMEA/CIL, volume 1

    Science.gov (United States)

    Prust, Chet D.; Haufler, W. A.; Marino, A. J.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Orbital Maneuvering System (OMS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter OMS hardware. The IOA analysis defined the OMS as being comprised of the following subsystems: helium pressurization, propellant storage and distribution, Orbital Maneuvering Engine, and EPD and C. The IOA product for the OMS analysis consisted of 284 hardware and 667 EPD and C failure mode worksheets that resulted in 160 hardware and 216 EPD and C potential critical items (PCIs) being identified. A comparison was made of the IOA product to the NASA FMEA/CIL baseline which consisted of 101 hardware and 142 EPD and C CIL items.

  12. Performance of an in-house human immunodeficiency virus type 1 genotyping system for assessment of drug resistance in Cuba.

    Science.gov (United States)

    Alemán, Yoan; Vinken, Lore; Kourí, Vivian; Pérez, Lissette; Álvarez, Alina; Abrahantes, Yeissel; Fonseca, Carlos; Pérez, Jorge; Correa, Consuelo; Soto, Yudira; Schrooten, Yoeri; Vandamme, Anne-Mieke; Van Laethem, Kristel

    2015-01-01

    As commercial human immunodeficiency virus type 1 drug resistance assays are expensive, they are not commonly used in resource-limited settings. Hence, a more affordable in-house procedure was set up taking into account the specific epidemiological and economic circumstances of Cuba. The performance characteristics of the in-house assay were evaluated using clinical samples with various subtypes and resistance patterns. The lower limit of amplification was determined on dilutions series of 20 clinical isolates and ranged from 84 to 529 RNA copies/mL. For the assessment of trueness, 14 clinical samples were analyzed and the ViroSeq HIV-1 Genotyping System v2.0 was used as the reference standard. The mean nucleotide sequence identity between the two assays was 98.7% ± 1.0. Additionally, 99.0% of the amino acids at drug resistance positions were identical. The sensitivity and specificity in detecting drug resistance mutations was respectively 94.1% and 99.5%. Only few discordances in drug resistance interpretation patterns were observed. The repeatability and reproducibility were evaluated using 10 clinical samples with 3 replicates per sample. The in-house test was very precise as nucleotide sequence identity among paired nucleotide sequences ranged from 98.7% to 99.9%. The acceptance criteria were met by the in-house test for all performance characteristics, demonstrating a high degree of accuracy. Subsequently, the applicability in routine clinical practice was evaluated on 380 plasma samples. The amplification success rate was 91% and good quality consensus sequences encoding the entire protease and the first 335 codons in reverse transcriptase could be obtained for 99% of the successful amplicons. The reagent cost per sample using the in-house procedure was around € 80 per genotyping attempt. Overall, the in-house assay provided good results, was feasible with equipment and reagents available in Cuba and was half as expensive as commercial assays.

  13. RELAP5/MOD2 code assessment for the Semiscale Mod-2C Test S-LH-1

    International Nuclear Information System (INIS)

    Fineman, C.P.

    1986-01-01

    RELAP5/MOD2, Cycle 36.02, was assessed using data from Semiscale Mod-2C experiment S-LH-1. The major phenomena that occurred during the experiment were calculated by RELAP5/MOD2, although the duration and the magnitude of their effect on the transient were not always well calculated. Areas defined where further work was needed to improve the RELAP5 calculation include: (1) the system energy balance, (2) core interfacial drag, and 3) the heat transfer logic rod dryout criterion

  14. MELCOR 1.8.2 Assessment: IET direct containment heating tests

    Energy Technology Data Exchange (ETDEWEB)

    Kmetyk, L.N.

    1993-10-01

    MELCOR is a fully integrated, engineering-level computer code, being developed at Sandia National Laboratories for the USNRC, that models the entire spectrum of severe accident phenomena in a unified framework for both BWRs and PWRS. As part of an ongoing assessment program, the MELCOR computer code has been used to analyze several of the IET direct containment heating experiments done at 1:10 linear scale in the Surtsey test facility at Sandia and at 1:40 linear scale in the corium-water thermal interactions (CWTI) COREXIT test facility at Argonne National Laboratory. These MELCOR calculations were done as an open post-test study, with both the experimental data and CONTAIN results available to guide the selection of code input. Basecase MELCOR results are compared to test data in order to evaluate the new HPME DCH model recently added in MELCOR version 1.8.2. The effect of various user-input parameters in the HPME model, which define both the initial debris source and the subsequent debris interaction, were investigated in sensitivity studies. In addition, several other non-default input modelling changes involving other MELCOR code packages were required in our IET assessment analyses in order to reproduce the observed experiment behavior. Several calculations were done to identify whether any numeric effects exist in our DCH IET assessment analyses.

  15. Novel use of proton magnetic resonance spectroscopy (1HMRS to non-invasively assess placental metabolism.

    Directory of Open Access Journals (Sweden)

    Fiona C Denison

    Full Text Available Placental insufficiency is a major cause of antepartum stillbirth and fetal growth restriction (FGR. In affected pregnancies, delivery is expedited when the risks of ongoing pregnancy outweigh those of prematurity. Current tests are unable to assess placental function and determine optimal timing for delivery. An accurate, non-invasive test that clearly defines the failing placenta would address a major unmet clinical need. Proton magnetic resonance spectroscopy ((1H MRS can be used to assess the metabolic profile of tissue in-vivo. In FGR pregnancies, a reduction in N-acetylaspartate (NAA/choline ratio and detection of lactate methyl are emerging as biomarkers of impaired neuronal metabolism and fetal hypoxia, respectively. However, fetal brain hypoxia is a late and sometimes fatal event in placental compromise, limiting clinical utility of brain (1H MRS to prevent stillbirth. We hypothesised that abnormal placental (1H MRS may be an earlier biomarker of intrauterine hypoxia, affording the opportunity to optimise timing of delivery in at-risk fetuses.We recruited three women with severe placental insufficiency/FGR and three matched controls. Using a 3T MR system and a combination of phased-array coils, a 20×20×40 mm(1H MRS voxel was selected along the 'long-axis' of the placenta with saturation bands placed around the voxel to prevent contaminant signals. A significant choline peak (choline/lipid ratio 1.35-1.79 was detected in all healthy placentae. In contrast, in pregnancies complicated by FGR, the choline/lipid ratio was ≤0.02 in all placentae, despite preservation of the lipid peak (p<0.001.This novel proof-of-concept study suggests that in severe placental insufficiency/FGR, the observed 60-fold reduction in the choline/lipid ratio by (1H MRS may represent an early biomarker of critical placental insufficiency. Further studies will determine performance of this test and the potential role of 1H-MRS in the in-vivo assessment of

  16. Design of a controlled release system of OP-1 and TGF-β1 based in microparticles of sodium alginate and release characterization by HPLC-UV.

    Science.gov (United States)

    Oliva-Rodríguez, Ricardo; Pérez-Urizar, José; Dibildox-Alvarado, Estela; Martínez-Saldaña, María Consolación; Avelar-González, Francisco Javier; Flores-Reyes, Héctor; Pozos-Guillén, Amaury de Jesús; Guerrero-Barrera, Alma Lilián

    2011-12-01

    A new system for sustained release of growth factors, such as osteogenic protein 1 (OP-1) and transforming growth factor β1 (TGF-β1), intended to repair and promote dental tissue regeneration in rats was designed and characterized in this work. The release system was made with microparticles of sodium alginate, produced by ionic gelling dripping technique. The release profiles of OP-1 and TGF-β1 from biopolymer matrix were determined by high-performance liquid chromatography (HPLC), and with this purpose, an HPLC-UV method was developed. About 80% of each growth factor was released in the first 24 h, reaching almost 100% in 168 h. The system was tested during the tissue repair in rat molars in comparison with calcium hydroxide and both growth factors not encapsulated. The dentin sialoprotein (DSP) was used as a repair marker. It was detected by immunohistochemistry, after 14- and 28-d post-treatment. X (2) test (p ≤ 0.001) and Fisher exact test (p ≤ 0.05) were applied for assessment of the amount of immunostaining. The treatment with encapsulated OP-1 showed an increased DSP immunostaining after 14 d and did not find any significant difference with the immunostaining observed for calcium hydroxide treatment. Treatment with TGF-β1 did not show significant difference with calcium hydroxide. Treatment with both factors OP-1 and TGF-β1 showed higher DSP immunostaining in comparison with calcium hydroxide treatment. In conclusion, the combination of both growth factors encapsulated showed more DSP immunostaining in comparison with each one separated, either encapsulated or not.

  17. 48 CFR 1.602-1 - Authority.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Authority. 1.602-1 Section... ACQUISITION REGULATIONS SYSTEM Career Development, Contracting Authority, and Responsibilities 1.602-1 Authority. (a) Contracting officers have authority to enter into, administer, or terminate contracts and...

  18. The SAS4A/SASSYS-1 Safety Analysis Code System, Version 5

    Energy Technology Data Exchange (ETDEWEB)

    Fanning, T. H. [Argonne National Lab. (ANL), Argonne, IL (United States); Brunett, A. J. [Argonne National Lab. (ANL), Argonne, IL (United States); Sumner, T. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-01

    The SAS4A/SASSYS-1 computer code is developed by Argonne National Laboratory for thermal, hydraulic, and neutronic analysis of power and flow transients in liquidmetal- cooled nuclear reactors (LMRs). SAS4A was developed to analyze severe core disruption accidents with coolant boiling and fuel melting and relocation, initiated by a very low probability coincidence of an accident precursor and failure of one or more safety systems. SASSYS-1, originally developed to address loss-of-decay-heat-removal accidents, has evolved into a tool for margin assessment in design basis accident (DBA) analysis and for consequence assessment in beyond-design-basis accident (BDBA) analysis. SAS4A contains detailed, mechanistic models of transient thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, its coolant, fuel elements, and structural members to accident conditions. The core channel models in SAS4A provide the capability to analyze the initial phase of core disruptive accidents, through coolant heat-up and boiling, fuel element failure, and fuel melting and relocation. Originally developed to analyze oxide fuel clad with stainless steel, the models in SAS4A have been extended and specialized to metallic fuel with advanced alloy cladding. SASSYS-1 provides the capability to perform a detailed thermal/hydraulic simulation of the primary and secondary sodium coolant circuits and the balance-ofplant steam/water circuit. These sodium and steam circuit models include component models for heat exchangers, pumps, valves, turbines, and condensers, and thermal/hydraulic models of pipes and plena. SASSYS-1 also contains a plant protection and control system modeling capability, which provides digital representations of reactor, pump, and valve controllers and their response to input signal changes.

  19. Validation of an automated system for aliquoting of HIV-1 Env-pseudotyped virus stocks.

    Science.gov (United States)

    Schultz, Anke; Germann, Anja; Fuss, Martina; Sarzotti-Kelsoe, Marcella; Ozaki, Daniel A; Montefiori, David C; Zimmermann, Heiko; von Briesen, Hagen

    2018-01-01

    The standardized assessments of HIV-specific immune responses are of main interest in the preclinical and clinical stage of HIV-1 vaccine development. In this regard, HIV-1 Env-pseudotyped viruses play a central role for the evaluation of neutralizing antibody profiles and are produced according to Good Clinical Laboratory Practice- (GCLP-) compliant manual and automated procedures. To further improve and complete the automated production cycle an automated system for aliquoting HIV-1 pseudovirus stocks has been implemented. The automation platform consists of a modified Tecan-based system including a robot platform for handling racks containing 48 cryovials, a Decapper, a tubing pump and a safety device consisting of ultrasound sensors for online liquid level detection of each individual cryovial. With the aim to aliquot the HIV-1 pseudoviruses in an automated manner under GCLP-compliant conditions a validation plan was developed where the acceptance criteria-accuracy, precision as well as the specificity and robustness-were defined and summarized. By passing the validation experiments described in this article the automated system for aliquoting has been successfully validated. This allows the standardized and operator independent distribution of small-scale and bulk amounts of HIV-1 pseudovirus stocks with a precise and reproducible outcome to support upcoming clinical vaccine trials.

  20. 7 CFR 37.1 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... accordance with the regulations that may result in assessment of an organic certification program that... certifying agency's quality system and associated quality certification procedures used to certify organic... ASSESS ORGANIC CERTIFYING AGENCIES § 37.1 Definitions. Words used in this part in the singular form shall...

  1. Spent fuel pool cooling system upgrade for Kori Unit 1

    International Nuclear Information System (INIS)

    Sun Park, Jong; In Shin, Kyung

    2014-01-01

    Following Fukushima nuclear power plant accident, the needs for reliable performance of its own safety functions of Spent Fuel Pool Cooling System (SFPCS) has risen significantly to maintain the plant in a safe condition. Regulatory Guide 1.13 of United States Nuclear Regulatory Commission (USNRC) requires the SFPCS shall be designed safety related as Quality Group C and Seismic Category 1. However, the existing Spent Fuel Pool (SFP) of KORI Unit 1 was not designed as a safety system. In order to comply with the above licensing requirement for the extended operational life of KORI Unit 1, it has been decided to add a safety related Seismic Category 1 Makeup System to KORI Unit 1 and the existing SFPCS to be modified in dedicated channels with safety related equipment to enhance system's reliability as a means of providing diversity. This paper focuses on describing the relevant design requirements, applications, and supplemental facilities to the SFPCS of KORI Unit 1. (authors)

  2. NPP Mochovce units 1 and 2 diagnostic systems

    International Nuclear Information System (INIS)

    Heidenreich, S.

    1997-01-01

    In this paper the diagnostic systems (leak detection monitoring, vibration monitoring, lose parts monitoring, fatigue monitoring) of NPP Mochovce units 1 and 2 are presented. All of the designed diagnostic systems are personal computer based systems

  3. Industrial waste needs assessment. Phase 1

    International Nuclear Information System (INIS)

    Radel, R.J.; Willis, M.P.

    1993-10-01

    In January of 1992 a team was put together to begin the process of assessing the industrial waste needs of the Tennessee Valley. The team consisted of representatives from the various TVA Resource Group organizations. This initial team recommended as a starting point in the process a two-phase market research effort. A second team was then commissioned to conduct the first phase of this market research effort. The first phase of that marketing effort is now complete. This report contains an analysis of the data obtained through interviews of more than 168 individuals representing a similar number of organizations. A total of 37 TVA Resource Group employees were involved in the contact process from various organizations. In addition, the appendices provide summaries of the data used in designing the process and the reports of the Contact Coordinators (who were responsible for a series of visits). As a result of the data analysis, the Review Team makes the following recommendations: 1. Publish this report and distribute to the new management within TVA Resource Group as well as to all those participating as contacts, visitors, and contact coordinators. 2. The Resource Group management team, or management teams within each of the respective organizations within Resource Group, appoint Phase 2 assessement teams for as many of the problem areas listed in Table III as seem appropriate. We further recommend that, where possible, cross-organizational teams be used to examine individual problem areas. 3. Make this report available within Generating and Customer Groups, especially to the Customer Service Centers. 4. Establish a process to continue follow up with each of the contacts made in this assessment

  4. Industrial waste needs assessment. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Radel, R.J.; Willis, M.P. [eds.

    1993-10-01

    In January of 1992 a team was put together to begin the process of assessing the industrial waste needs of the Tennessee Valley. The team consisted of representatives from the various TVA Resource Group organizations. This initial team recommended as a starting point in the process a two-phase market research effort. A second team was then commissioned to conduct the first phase of this market research effort. The first phase of that marketing effort is now complete. This report contains an analysis of the data obtained through interviews of more than 168 individuals representing a similar number of organizations. A total of 37 TVA Resource Group employees were involved in the contact process from various organizations. In addition, the appendices provide summaries of the data used in designing the process and the reports of the Contact Coordinators (who were responsible for a series of visits). As a result of the data analysis, the Review Team makes the following recommendations: 1. Publish this report and distribute to the new management within TVA Resource Group as well as to all those participating as contacts, visitors, and contact coordinators. 2. The Resource Group management team, or management teams within each of the respective organizations within Resource Group, appoint Phase 2 assessement teams for as many of the problem areas listed in Table III as seem appropriate. We further recommend that, where possible, cross-organizational teams be used to examine individual problem areas. 3. Make this report available within Generating and Customer Groups, especially to the Customer Service Centers. 4. Establish a process to continue follow up with each of the contacts made in this assessment.

  5. WIPP supplementary roof support system Room 1, Panel 1: Geotechnical field data analysis report

    International Nuclear Information System (INIS)

    1993-03-01

    The design of the Room 1, Panel 1, supplementary roof support system was finalized in September 1991, and the system successfully installed in the test bin area between the bulkheads by December 1991. Simultaneously with the support system installation, existing monitoring system was upgraded to meet the needs of the installed roof support. This included extensometers, closure stations, rockbolt load cells as well as survey measurements of roof sag and floor lift. A Project Control Group (PCG) was established in order to monitor room and support system performance. Weekly meetings of the PCG were held to review all monitored data against criteria set in the initial design, and to modify these where necessary. Records of these meetings have been kept, with copies of all data summaries and action notes. These data records are maintained in the Engineering data files. After more than ten months of monitoring and reviewing experience, several modifications have been made both to the way data has been reported as well as to the load adjustment criteria. The support system has performed as expected in the design, with no signs of instability developing considering the rates of roof deformation, the rock bolt loads and the observed fracture behavior in the roof. This is particularly true of the horizon in which the rockbolt anchors are located, the most critical part of the design. The distribution of load build-up, throughout the 286 rockbolt load cells installed, in the Room 1 has been found satisfactory, and the load increases as evaluated by the PCG on a weekly basis have been within the acceptable range. The minimum life of the installed support system is estimated at 15 years based on the highest roof expansion rate experienced to date. This report provides analysis of geotechnical field data collected up to December 1992

  6. DEVELOPMENT AND ASSESSMENT OF A SCORE™ DEMO2.1 THERMO-ACOUSTIC ENGINE

    Directory of Open Access Journals (Sweden)

    BAIMAN CHEN

    2013-04-01

    Full Text Available The early low-cost, wood burning Thermo-Acoustic Engine (TAE known as Demo2.0-build-1 was developed by SCORE™ at the UK Centre and was capable of achieving 22.7 Watts of electricity. This prototype was limited to an operating temperature of about 300oC and due to excessive leaks could not operate continuously above ambient pressure. To absorb a thermal heat input of 4.4 kW from the burning wood so as to fulfil the required acoustic power, the Hot Heat Exchanger (HHX requires heating to the highest possible temperature. Therefore, a corrugated stainless steel plate HHX design that maximises heating surface area was adopted to the current Demo2 TAE design. In addition, the system is often pressurised to achieve higher acoustic intensity. Rigorous sealing of the system at high temperature is also required. A Demo2.1 TAE design based on the Demo2 TAE design and its prototype which is developed recently by the SCORE™ Centre in Malaysia was successfully constructed and well integrated with the stove. During the early construction and assembly process, fabrication difficulties and serious leak problems around the HHX’s edges were found when the apparatus operated at high temperatures. This is because the uneven geometrical HHX (convolution profile makes it difficult and relatively costly to be sealed. The Demo2.1 TAE is focused on the sealing efficiency and effective manufacturing cost by meantime to allow further modification variation. The design was made to adopt the local manufacturing technologies and materials available or easy to access in Malaysia. It also aims to minimise the parasitic heat losses to lower the system onset temperature. By removing the Linear Alternator and Tuning Volume from the system, preliminary measurements shown that the apparatus was oscillating at the frequency of 70 Hz. A much lower onset temperature was observed at around 144oC for the new configuration when the apparatus was oscillating at approximately 200 Pa

  7. Functional characterization of the ER stress induced X-box-binding protein-1 (Xbp-1 in the porcine system

    Directory of Open Access Journals (Sweden)

    Jin Dong-Il

    2011-05-01

    Full Text Available Abstract Background The unfolded protein response (UPR is an evolutionary conserved adaptive reaction for increasing cell survival under endoplasmic reticulum (ER stress conditions. X-box-binding protein-1 (Xbp1 is a key transcription factor of UPR that activates genes involved in protein folding, secretion, and degradation to restore ER function. The UPR induced by ER stress was extensively studied in diseases linked to protein misfolding and aggregations. However, in the porcine system, genes in the UPR pathway were not investigated. In this study, we isolated and characterized the porcine Xbp1 (pXbp1 gene in ER stress using porcine embryonic fibroblast (PEF cells and porcine organs. ER stress was induced by the treatment of tunicamycin and cell viability was investigated by the MTT assay. For cloning and analyzing the expression pattern of pXbp1, RT-PCR analysis and Western blot were used. Knock-down of pXbp1 was performed by the siRNA-mediated gene silencing. Results We found that the pXbp1 mRNA was the subject of the IRE1α-mediated unconventional splicing by ER stress. Knock-down of pXbp1 enhanced ER stress-mediated cell death in PEF cells. In adult organs, pXbp1 mRNA and protein were expressed and the spliced forms were detected. Conclusions It was first found that the UPR mechanisms and the function of pXbp1 in the porcine system. These results indicate that pXbp1 plays an important role during the ER stress response like other animal systems and open a new opportunity for examining the UPR pathway in the porcine model system.

  8. Readiness evaluation report for operation of the 200-ZP-1 pump-and-treat system

    International Nuclear Information System (INIS)

    Lehrschall, R. R.

    1996-07-01

    The 200-ZP-1 Readiness Evaluation Team has completed a readiness evaluation (RE) of the 200-ZP-1 Interim Remedial Measure. During the RE process, other Environmental Restoration Contractor and Hanford Site project activities were assessed (i.e., using lessons learned reviews) for applicability to the 200-ZP-1 RE. Nine additional areas were discovered to be applicable to the 200-ZP-1 IRM and were incorporated into the RE process as functional readiness requirements. The goal of the 200-ZP-1 Operable Unit IRM is to reduce further migration of the carbon tetrachloride, chloroform, and trichloroethylene in the groundwater of the 200 West Area. The IRM treatment system has been designed to initiate hydraulic containment of the contaminant mass in the high-concentration portion of the CCl 4 plume

  9. (Vapour + liquid) equilibrium data for the azeotropic {1,1-difluoroethane (R152a) + 1,1,2,2-Tetrafluoroethane (R134)} system at various temperatures from (258.150 to 288.150) K

    International Nuclear Information System (INIS)

    Guo, Hao; Gong, Maoqiong; Dong, Xueqiang; Wu, Jianfeng

    2012-01-01

    Highlights: ► VLE data for the {R152a + R134} system were measured. ► The experiment is based on the static–analytic method. ► The VLE data were correlated using the PR–HV–NRTL model. ► A negative azeotropic behaviour was found. - Abstract: (Vapour + liquid) equilibrium (VLE) data for the {1,1-difluoroethane (R152a) + 1,1,2,2-Tetrafluoroethane (R134)} system were measured at T = (258.150 to 288.150) K. The experiment is based on a static–analytic method. Experimental data were correlated with the Peng–Robinson equation of state (PR EoS) and the Huron–Vidal (HV) mixing rule involving the NRTL activity coefficient model. The results show good agreement with experimental results for the binary system at each temperature. It was found that the system has a negative azeotropic behaviour within the temperature range measured here.

  10. The EUCLID/V1 Integrated Code for Safety Assessment of Liquid Metal Cooled Fast Reactors. Part 1: Basic Models

    Science.gov (United States)

    Mosunova, N. A.

    2018-05-01

    The article describes the basic models included in the EUCLID/V1 integrated code intended for safety analysis of liquid metal (sodium, lead, and lead-bismuth) cooled fast reactors using fuel rods with a gas gap and pellet dioxide, mixed oxide or nitride uranium-plutonium fuel under normal operation, under anticipated operational occurrences and accident conditions by carrying out interconnected thermal-hydraulic, neutronics, and thermal-mechanical calculations. Information about the Russian and foreign analogs of the EUCLID/V1 integrated code is given. Modeled objects, equation systems in differential form solved in each module of the EUCLID/V1 integrated code (the thermal-hydraulic, neutronics, fuel rod analysis module, and the burnup and decay heat calculation modules), the main calculated quantities, and also the limitations on application of the code are presented. The article also gives data on the scope of functions performed by the integrated code's thermal-hydraulic module, using which it is possible to describe both one- and twophase processes occurring in the coolant. It is shown that, owing to the availability of the fuel rod analysis module in the integrated code, it becomes possible to estimate the performance of fuel rods in different regimes of the reactor operation. It is also shown that the models implemented in the code for calculating neutron-physical processes make it possible to take into account the neutron field distribution over the fuel assembly cross section as well as other features important for the safety assessment of fast reactors.

  11. (Vapour + liquid) equilibria of the {1,1-difluoroethane (HFC-152a) + n-butane (HC-600)} system

    International Nuclear Information System (INIS)

    Im, Jihoon; Lee, Gangwon; Lee, Yong-Jin; Kim, Hwayong

    2007-01-01

    Binary (vapour + liquid) equilibrium data were obtained for the {1,1-difluoroethane (HFC-152a) + n-butane (HC-600)} system at temperatures from 313.15 K to 363.15 K. These experiments were carried out with a circulating-type apparatus with on-line gas chromatography. The experimental data were correlated well by Peng-Robinson equation of state using the Wong-Sandler mixing rules. This system shows positive azeotropic phase behaviour

  12. Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom.

    Science.gov (United States)

    Jiang, Yun; Ma, Dan; Keenan, Kathryn E; Stupic, Karl F; Gulani, Vikas; Griswold, Mark A

    2017-10-01

    The purpose of this study was to evaluate accuracy and repeatability of T 1 and T 2 estimates of a MR fingerprinting (MRF) method using the ISMRM/NIST MRI system phantom. The ISMRM/NIST MRI system phantom contains multiple compartments with standardized T 1 , T 2 , and proton density values. Conventional inversion-recovery spin echo and spin echo methods were used to characterize the T 1 and T 2 values in the phantom. The phantom was scanned using the MRF-FISP method over 34 consecutive days. The mean T 1 and T 2 values were compared with the values from the spin echo methods. The repeatability was characterized as the coefficient of variation of the measurements over 34 days. T 1 and T 2 values from MRF-FISP over 34 days showed a strong linear correlation with the measurements from the spin echo methods (R 2  = 0.999 for T 1 ; R 2  = 0.996 for T 2 ). The MRF estimates over the wide ranges of T 1 and T 2 values have less than 5% variation, except for the shortest T 2 relaxation times where the method still maintains less than 8% variation. MRF measurements of T 1 and T 2 are highly repeatable over time and across wide ranges of T 1 and T 2 values. Magn Reson Med 78:1452-1457, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. Assessing Associations between the AURKA-HMMR-TPX2-TUBG1 Functional Module and Breast Cancer Risk in BRCA1/2 Mutation Carriers

    DEFF Research Database (Denmark)

    Blanco, Ignacio; Kuchenbaecker, Karoline; Cuadras, Daniel

    2015-01-01

    While interplay between BRCA1 and AURKA-RHAMM-TPX2-TUBG1 regulates mammary epithelial polarization, common genetic variation in HMMR (gene product RHAMM) may be associated with risk of breast cancer in BRCA1 mutation carriers. Following on these observations, we further assessed the link between ...

  14. 41 CFR 101-1.104-1 - Publication.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Publication. 101-1.104-1 Section 101-1.104-1 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.104-1...

  15. Remedial action and waste disposal project -- 300-FF-1 remedial action readiness assessment plan

    International Nuclear Information System (INIS)

    April, J.G.; Carlson, R.A.; Greif, A.A.; Johnson, C.R.; Orewiler, R.I.; Perry, D.M.; Plastino, J.C.; Roeck, F.V.; Tuttle, B.G.

    1997-04-01

    This Readiness Assessment Plan presents the methodology used to assess the readiness of the 300-FF-1 Remedial Action Project. Remediation involves the excavation, treatment if applicable, and final disposal of contaminated soil and debris associated with the waste sites in the 300-FF-1 Operable Unit. The scope of the 300-FF-1 remediation is to excavate, transport, and dispose of contaminated solid from sites identified in the 300-FF-1 Operable Unit

  16. The self assessment at ANGRA 1 NPP in Brazil

    International Nuclear Information System (INIS)

    Werdine, H. Jr.

    1996-01-01

    Angra 1 considers the Self-Assessment concept an extremely valuable tool to enhance plant safety and plant performance. A formal guidance procedure to apply this methodology does not exist at our plant and should be developed and implemented as soon as possible. Some portions of this methodology already exist with different names. The root cause analysis of in-house incident reports is a heavy portion of a sound self-assessment approach. International related experience from top performance plants should be used. International meetings, such as this one, should be convened and formal guidance from the IAEA should be written

  17. The self assessment at ANGRA 1 NPP in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Werdine, H Jr [Furnas Centrais Eletricas S.A., Rio de Janeiro (Brazil)

    1997-12-31

    Angra 1 considers the Self-Assessment concept an extremely valuable tool to enhance plant safety and plant performance. A formal guidance procedure to apply this methodology does not exist at our plant and should be developed and implemented as soon as possible. Some portions of this methodology already exist with different names. The root cause analysis of in-house incident reports is a heavy portion of a sound self-assessment approach. International related experience from top performance plants should be used. International meetings, such as this one, should be convened and formal guidance from the IAEA should be written.

  18. Powered Explicit Guidance Modifications and Enhancements for Space Launch System Block-1 and Block-1B Vehicles

    Science.gov (United States)

    Von der Porten, Paul; Ahmad, Naeem; Hawkins, Matt; Fill, Thomas

    2018-01-01

    NASA is currently building the Space Launch System (SLS) Block-1 launch vehicle for the Exploration Mission 1 (EM-1) test flight. NASA is also currently designing the next evolution of SLS, the Block-1B. The Block-1 and Block-1B vehicles will use the Powered Explicit Guidance (PEG) algorithm (of Space Shuttle heritage) for closed loop guidance. To accommodate vehicle capabilities and design for future evolutions of SLS, modifications were made to PEG for Block-1 to handle multi-phase burns, provide PEG updated propulsion information, and react to a core stage engine out. In addition, due to the relatively low thrust-to-weight ratio of the Exploration Upper Stage (EUS) and EUS carrying out Lunar Vicinity and Earth Escape missions, certain enhancements to the Block-1 PEG algorithm are needed to perform Block-1B missions to account for long burn arcs and target translunar and hyperbolic orbits. This paper describes the design and implementation of modifications to the Block-1 PEG algorithm as compared to Space Shuttle. Furthermore, this paper illustrates challenges posed by the Block-1B vehicle and the required PEG enhancements. These improvements make PEG capable for use on the SLS Block-1B vehicle as part of the Guidance, Navigation, and Control (GN&C) System.

  19. Viscosities and refractive indices of binary systems acetone+1-propanol, acetone+1,2-propanediol and acetone+1,3-propanediol

    Directory of Open Access Journals (Sweden)

    Živković Emila M.

    2014-01-01

    Full Text Available Viscosities and refractive indices of three binary systems, acetone+1-propanol, acetone+1,2-propanediol and acetone+1,3-propanediol, were measured at eight temperatures (288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, 323.15K and at atmospheric pressure. From these data viscosity deviations and deviations in refractive index were calculated and fitted to the Redlich-Kister equation. The viscosity modelling was done by two types of models: predictive UNIFAC-VISCO and ASOG VISCO and correlative Teja-Rice and McAlister equations. The refractive indices of binary mixtures were predicted by various mixing rules and compared with experimental data. [Projekat Ministarstva nauke Republike Srbije, br. 172063

  20. SLS Block 1-B and Exploration Upper Stage Navigation System Design

    Science.gov (United States)

    Oliver, T. Emerson; Park, Thomas B.; Smith, Austin; Anzalone, Evan; Bernard, Bill; Strickland, Dennis; Geohagan, Kevin; Green, Melissa; Leggett, Jarred

    2018-01-01

    The SLS Block 1B vehicle is planned to extend NASA's heavy lift capability beyond the initial SLS Block 1 vehicle. The most noticeable change for this vehicle from SLS Block 1 is the swapping of the upper stage from the Interim Cryogenic Propulsion stage (ICPS), a modified Delta IV upper stage, to the more capable Exploration Upper Stage (EUS). As the vehicle evolves to provide greater lift capability and execute more demanding missions so must the SLS Integrated Navigation System to support those missions. The SLS Block 1 vehicle carries two independent navigation systems. The responsibility of the two systems is delineated between ascent and upper stage flight. The Block 1 navigation system is responsible for the phase of flight between the launch pad and insertion into Low-Earth Orbit (LEO). The upper stage system assumes the mission from LEO to payload separation. For the Block 1B vehicle, the two functions are combined into a single system intended to navigate from ground to payload insertion. Both are responsible for self-disposal once payload delivery is achieved. The evolution of the navigation hardware and algorithms from an inertial-only navigation system for Block 1 ascent flight to a tightly coupled GPS-aided inertial navigation system for Block 1-B is described. The Block 1 GN&C system has been designed to meet a LEO insertion target with a specified accuracy. The Block 1-B vehicle navigation system is designed to support the Block 1 LEO target accuracy as well as trans-lunar or trans-planetary injection accuracy. This is measured in terms of payload impact and stage disposal requirements. Additionally, the Block 1-B vehicle is designed to support human exploration and thus is designed to minimize the probability of Loss of Crew (LOC) through high-quality inertial instruments and Fault Detection, Isolation, and Recovery (FDIR) logic. The preliminary Block 1B integrated navigation system design is presented along with the challenges associated with

  1. Paraoxonase 1 activity and genotyping in systemic lupus ...

    African Journals Online (AJOL)

    Introduction: Systemic lupus erythematosus (SLE) is characterized by an enhanced risk of atherosclerosis and cardiovascular diseases (CVD). Human serum paraoxonase 1 (PON1), an antioxidant enzyme closely associated with high density lipoprotein (HDL), has been implicated in the prevention of low density ...

  2. Assessing Associations between the AURKA-HMMR-TPX2-TUBG1 Functional Module and Breast Cancer Risk in BRCA1/2 Mutation Carriers

    NARCIS (Netherlands)

    Blanco, Ignacio; Kuchenbaecker, Karoline; Cuadras, Daniel; Wang, Xianshu; Barrowdale, Daniel; Ruiz de Garibay, Gorka; Librado, Pablo; Sanchez-Gracia, Alejandro; Rozas, Julio; Bonifaci, Nuria; McGuffog, Lesley; Pankratz, Vernon S.; Islam, Abul; Mateo, Francesca; Berenguer, Antoni; Petit, Anna; Catala, Isabel; Brunet, Joan; Feliubadalo, Lidia; Tornero, Eva; Benitez, Javier; Osorio, Ana; Cajal, Teresa Ramon Y.; Nevanlinna, Heli; Aittomaki, Kristiina; Arun, Banu K.; Toland, Amanda E.; Karlan, Beth Y.; Walsh, Christine; Lester, Jenny; Greene, Mark H.; Mai, Phuong L.; Nussbaum, Robert L.; Andrulis, Irene L.; Domchek, Susan M.; Nathanson, Katherine L.; Rebbeck, Timothy R.; Barkardottir, Rosa B.; Jakubowska, Anna; Lubinski, Jan; Durda, Katarzyna; Jaworska-Bieniek, Katarzyna; Claes, Kathleen; Van Maerken, Tom; Diez, Orland; Hansen, Thomas V.; Jonson, Lars; Gerdes, Anne-Marie; Ejlertsen, Bent; de la Hoya, Miguel; Caldes, Trinidad; Dunning, Alison M.; Oliver, Clare; Fineberg, Elena; Cook, Margaret; Peock, Susan; McCann, Emma; Murray, Alex; Jacobs, Chris; Pichert, Gabriella; Lalloo, Fiona; Chu, Carol; Dorkins, Huw; Paterson, Joan; Ong, Kai-Ren; Teixeira, Manuel R.; Teixeira, M.R.; Hogervorst, Frans B. L.; van der Hout, Annemarie H.; Seynaeve, Caroline; van der Luijt, Rob B.; Ligtenberg, Marjolijn J. L.; Devilee, Peter; Wijnen, Juul T.; Rookus, Matti A.; Meijers-Heijboer, Hanne E. J.; Blok, Marinus J.; van den Ouweland, Ans M. W.; Aalfs, Cora M.; Rodriguez, Gustavo C.; Phillips, Kelly-Anne A.; Piedmonte, Marion; Nerenstone, Stacy R.; Bae-Jump, Victoria L.; O'Malley, David M.; Ratner, Elena S.; Schmutzler, Rita K.; Wappenschmidt, Barbara; Rhiem, Kerstin; Engel, Christoph; Meindl, Alfons; Ditsch, Nina; Arnold, Norbert; Plendl, Hansjoerg J.; Niederacher, Dieter; Sutter, Christian; Wang-Gohrke, Shan; Steinemann, Doris; Preisler-Adams, Sabine; Kast, Karin; Varon-Mateeva, Raymonda; Gehrig, Andrea; Bojesen, Anders; Pedersen, Inge Sokilde; Sunde, Lone; Jensen, Uffe Birk; Thomassen, Mads; Kruse, Torben A.; Foretova, Lenka; Peterlongo, Paolo; Bernard, Loris; Peissel, Bernard; Scuvera, Giulietta; Manoukian, Siranoush; Radice, Paolo; Ottini, Laura; Montagna, Marco; Agata, Simona; Maugard, Christine; Simard, Jacques; Soucy, Penny; Berger, Andreas; Fink-Retter, Anneliese; Singer, Christian F.; Rappaport, Christine; Geschwantler-Kaulich, Daphne; Tea, Muy-Kheng; Pfeiler, Georg; John, Esther M.; Miron, Alex; Neuhausen, Susan L.; Terry, Mary Beth; Chung, Wendy K.; Daly, Mary B.; Goldgar, David E.; Janavicius, Ramunas; Dorfling, Cecilia M.; van Rensburg, Elisabeth J.; Fostira, Florentia; Konstantopoulou, Irene; Garber, Judy; Godwin, Andrew K.; Olah, Edith; Narod, Steven A.; Rennert, Gad; Paluch, Shani Shimon; Laitman, Yael; Friedman, Eitan; Liljegren, Annelie; Rantala, Johanna; Stenmark-Askmalm, Marie; Loman, Niklas; Imyanitov, Evgeny N.; Hamann, Ute; Spurdle, Amanda B.; Healey, Sue; Weitzel, Jeffrey N.; Herzog, Josef; Margileth, David; Gorrini, Chiara; Esteller, Manel; Gomez, Antonio; Sayols, Sergi; Vidal, Enrique; Heyn, Holger; Stoppa-Lyonnet, Dominique; Leone, Melanie; Barjhoux, Laure; Fassy-Colcombet, Marion; de Pauw, Antoine; Lasset, Christine; Ferrer, Sandra Fert; Castera, Laurent; Berthet, Pascaline; Cornelis, Francois; Bignon, Yves-Jean; Damiola, Francesca; Mazoyer, Sylvie; Sinilnikova, Olga M.; Maxwell, Christopher A.; Vijai, Joseph; Robson, Mark; Kauff, Noah; Corines, Marina J.; Villano, Danylko; Cunningham, Julie; Lee, Adam; Lindor, Noralane; Lazaro, Conxi; Easton, Douglas F.; Offit, Kenneth; Chenevix-Trench, Georgia; Couch, Fergus J.; Antoniou, Antonis C.; Angel Pujana, Miguel

    2015-01-01

    While interplay between BRCA1 and AURKA-RHAMM-TPX2-TUBG1 regulates mammary epithelial polarization, common genetic variation in HMMR (gene product RHAMM) may be associated with risk of breast cancer in BRCA1 mutation carriers. Following on these observations, we further assessed the link between the

  3. Is Cygus X-1 a chaotic dynamical system?

    International Nuclear Information System (INIS)

    Unno, Wasaburo; Yoneyama, Tadaoki; Urata, Kenji; Masaki, Isao; Kondo, Masa-aki; Inoue, Hajime.

    1990-01-01

    X-ray data of Cyg X-1 observed by the Tenma satellite were analyzed to determine whether Cyg X-1 is a chaotic dynamical system of low dimension. Since Poisson noise disturbs the determination of the attractor dimension of the system, comparative studies were carried out for the Cyg X-1 data relative to artificial data of purely stochastic Poisson noise and to a Lorenz attractor plus noise. The attractor dimension was searched using trajectories of time series data in phase space, the dimension of which was varied up to 21. The relation between the attractor dimension and the phase-space dimension for the Cyg X-1 data starts to deviate from that of noise data from a phase-space dimension of about 7, showing the presence of an attractor with a dimension of about 7 or less. Though three positive Lyapunov exponents were calculated, they are too small (∼10 -2 ) to prove with certainty that the Cyg X-1 attractor should be a strange attractor. (author)

  4. International collaboration to assess the risk of Guillain Barré Syndrome following Influenza A (H1N1) 2009 monovalent vaccines.

    Science.gov (United States)

    Dodd, Caitlin N; Romio, Silvana A; Black, Steven; Vellozzi, Claudia; Andrews, Nick; Sturkenboom, Miriam; Zuber, Patrick; Hua, Wei; Bonhoeffer, Jan; Buttery, Jim; Crawford, Nigel; Deceuninck, Genevieve; de Vries, Corinne; De Wals, Philippe; Gutierrez-Gimeno, M Victoria; Heijbel, Harald; Hughes, Hayley; Hur, Kwan; Hviid, Anders; Kelman, Jeffrey; Kilpi, Tehri; Chuang, S K; Macartney, Kristine; Rett, Melisa; Lopez-Callada, Vesta Richardson; Salmon, Daniel; Gimenez-Sanchez, Francisco; Sanz, Nuria; Silverman, Barbara; Storsaeter, Jann; Thirugnanam, Umapathi; van der Maas, Nicoline; Yih, Katherine; Zhang, Tao; Izurieta, Hector

    2013-09-13

    The global spread of the 2009 novel pandemic influenza A (H1N1) virus led to the accelerated production and distribution of monovalent 2009 Influenza A (H1N1) vaccines (pH1N1). This pandemic provided the opportunity to evaluate the risk of Guillain-Barré syndrome (GBS), which has been an influenza vaccine safety concern since the swine flu pandemic of 1976, using a common protocol among high and middle-income countries. The primary objective of this project was to demonstrate the feasibility and utility of global collaboration in the assessment of vaccine safety, including countries both with and without an established infrastructure for vaccine active safety surveillance. A second objective, included a priori, was to assess the risk of GBS following pH1N1 vaccination. The primary analysis used the self-controlled case series (SCCS) design to estimate the relative incidence (RI) of GBS in the 42 days following vaccination with pH1N1 vaccine in a pooled analysis across databases and in analysis using a meta-analytic approach. We found a relative incidence of GBS of 2.42 (95% CI 1.58-3.72) in the 42 days following exposure to pH1N1 vaccine in analysis of pooled data and 2.09 (95% CI 1.28-3.42) using the meta-analytic approach. This study demonstrates that international collaboration to evaluate serious outcomes using a common protocol is feasible. The significance and consistency of our findings support a conclusion of an association between 2009 H1N1 vaccination and GBS. Given the rarity of the event the relative incidence found does not provide evidence in contradiction to international recommendations for the continued use of influenza vaccines. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Design and cost analysis of 1 kW photovoltaic system based on actual performance in Indian scenario

    Directory of Open Access Journals (Sweden)

    Shahzad Ahsan

    2016-09-01

    Full Text Available The exhaustion of conventional resources and its effect on climate requires an urgent call for the substitute power resources to convene up the current power requirement. Solar energy is an endless, unsoiled and prospective energy source among all other nonconventional energy options. As more concentration is being done on focal point for the development of renewable energy capital globally. To ascertain their viability it is necessary to do the economic and technical assessments of these resources. This paper presents designing aspects and assessments of solar PV system based on field and actual performance. The study is based on design of solar PV system and a case study based on cost analysis of 1.0 kW off-grid photovoltaic energy system installed at Jamia Millia Islamia, New Delhi (28.5616° N, 77.2802° E, and about 293 m above sea level India. Both monthly and weekly costs of energy produced by the 1 kW PV system have been calculated. In addition, the solar PV 1 kW system can give internal rate of return of about 1.714% on investment. Based on assumptions used in this study, solar 1 kW PV system of Rs. 0.9724/kWh is estimated for a project with profitable life of 25 years with no other financial support. This translates to Rs. 80,000 payment over the livelier cost of energy of 1 kWh generated by the system. However, if the financial support is more than 50% of the initial investment cost, no further payment fee is necessary to support this type of system. Basically this system has been designed for small home located at the place of availability of grid power is rare. 1 kW PV solar system is also very useful in rural areas of India. India as a subcontinent receives great amounts of solar radiation annually.

  6. In vitro mutagenicity and genotoxicity study of 1,2-dichloroethylene, 1,1,2-trichloroethane, 1,3-dichloropropane, 1,2,3-trichloropropane and 1,1,3-trichloropropene, using the micronucleus test and the alkaline single cell gel electrophoresis technique (comet assay) in human lymphocytes.

    Science.gov (United States)

    Tafazoli, M; Kirsch-Volders, M

    1996-12-20

    The main objective of this study was to compare the cytotoxic genotoxic and mutagenic activity of a number of chlorinated aliphatic hydrocarbons, which are widely used as chemical intermediates, solvents, degreasing agents etc. in industry, and to establish the structure-toxicity relationship of the chemicals by using the most adequate determinants in estimating their toxicity. The mutagenicity and cytotoxicity of some of the candidate chemicals, namely 1,2-dichloroethylene, 1,1,2-trichloroethane, 1,3-dichloropropane, 1,2,3-trichloropropane and 1,1,3-trichloropropene were evaluated in an in vitro micronucleus assay. The cytokinesis-block methodology was applied on human lymphocytes in the presence or absence of an external metabolic activation system (S9-mix). In the micronucleus assay, all test substances, except 1,2,3-trichloropropane with and without S9-mix and 1,1,2-trichloroethane without S9-mix in the repeated experiment, exhibited a low but statistically significant mutagenic activity, compared to the concurrent control. However, none of the five chemicals was able to induce a clear and reproducible linear dose-dependent increase in micronucleus frequencies in this assay. Generally, mutagenic activity of the chemicals was found in the absence of severe cytotoxicity and/or cell cycle delay. The DNA breakage capacity and the cytotoxicity of these chemicals were also assessed in the alkaline single cell gel (SCG) electrophoresis test (comet assay) with and without S9-mix in isolated human lymphocytes. All chemical compounds induced DNA breakage, in the presence or absence of the metabolic activation system, at the doses tested. The data showed that the DNA reactivity of the chemicals increased with increasing degree of halogenation. The results of the present work suggested that the comet assay might be a more suitable and sensitive screening method than the micronucleus test for this particular class of compound. However, both assays do detect different

  7. Pelvic organ prolapse repair using the Uphold™ Vaginal Support System: a 1-year multicenter study.

    Science.gov (United States)

    Altman, Daniel; Mikkola, Tomi S; Bek, Karl Möller; Rahkola-Soisalo, Päivi; Gunnarsson, Jonas; Engh, Marie Ellström; Falconer, Christian

    2016-09-01

    The objective was to assess safety and clinical outcomes in women operated on using the Uphold™ Lite Vaginal Support System. We carried out a 1-year, multicenter, prospective, single cohort study of 207 women with symptomatic Pelvic Organ Prolapse Quantification (POP-Q) stage ≥2 apical pelvic organ prolapse, with or without concomitant anterior vaginal wall prolapse. Safety data were collected using a standardized questionnaire. Anatomical outcome was assessed by the POP-Q and subjective outcomes by the Pelvic Floor Distress Inventory after 2 months and 1 year using a one-way repeated measures analysis of variance. Pain was evaluated using a visual analog scale. The overall rate of serious complications was 4.3 % (9 out of 207 patients), including 3 patients with bladder perforations, 1 with bleeding >1,000 ml, 2 who had undergone re-operations with complete mesh removal because of pain, and 3 surgical interventions during follow-up because of mesh exposure. POP-Q stage ≤1 after 1 year was 94 % and subjective symptom relief was reported by 91 % of patients (p transvaginal mesh kits.

  8. Fragrance material review on 1-(2,4,4,5,5-pentamethyl-1-cyclopenten-1-yl)ethan-1-one.

    Science.gov (United States)

    Scognamiglio, J; Letizia, C S; Api, A M

    2013-12-01

    A toxicologic and dermatologic review of 1-(2,4,4,5,5-pentamethyl-1-cyclopenten-1-yl)ethan-1-one when used as a fragrance ingredient is presented. 1-(2,4,4,5,5-Pentamethyl-1-cyclopenten-1-yl)ethan-1-one is a member of the fragrance structural group Alkyl Cyclic Ketones. These fragrances can be described as being composed of an alkyl, R1, and various substituted and bicyclic saturated or unsaturated cyclic hydrocarbons, R2, in which one of the rings may include up to 12 carbons. Alternatively, R2 may be a carbon bridge of C2-C4 carbon chain length between the ketone and cyclic hydrocarbon. This review contains a detailed summary of all available toxicology and dermatology papers that are related to this individual fragrance ingredient and is not intended as a stand-alone document. Available data for 1-(2,4,4,5,5-pentamethyl-1-cyclopenten-1-yl)ethan-1-one were evaluated then summarized and includes physical properties, acute toxicity, skin irritation, mucous membrane (eye) irritation, skin sensitization, phototoxicity, and photoallergy data. A safety assessment of the entire Alkyl Cyclic Ketones will be published simultaneously with this document; please refer to Belsito et al. (Belsito, D., Bickers, D., Bruze, M., Calow, P., Dagli, M., Fryer, A.D., Greim, H., Miyachi, Y., Saurat, J.H., Sipes, I.G., 2013. A Toxicologic and Dermatologic Assessment of Alkyl Cyclic Ketones When Used as Fragrance Ingredients (submitted for publication)) for an overall assessment of the safe use of this material and all Alkyl Cyclic Ketones in fragrances. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Influence of ESAT-6 secretion system 1 (RD1) of Mycobacterium tuberculosis on the interaction between mycobacteria and the host immune system.

    Science.gov (United States)

    Majlessi, Laleh; Brodin, Priscille; Brosch, Roland; Rojas, Marie-Jésus; Khun, Huot; Huerre, Michel; Cole, Stewart T; Leclerc, Claude

    2005-03-15

    The chromosomal locus encoding the early secreted antigenic target, 6 kDa (ESAT-6) secretion system 1 of Mycobacterium tuberculosis, also referred to as "region of difference 1 (RD1)," is absent from Mycobacterium bovis bacillus Calmette-Guerin (BCG). In this study, using low-dose aerosol infection in mice, we demonstrate that BCG complemented with RD1 (BCG::RD1) displays markedly increased virulence which albeit does not attain that of M. tuberculosis H37Rv. Nevertheless, phenotypic and functional analyses of immune cells at the site of infection show that the capacity of BCG::RD1 to initiate recruitment/activation of immune cells is comparable to that of fully virulent H37Rv. Indeed, in contrast to the parental BCG, BCG::RD1 mimics H37Rv and induces substantial influx of activated (CD44highCD45RB(-)CD62L(-)) or effector (CD45RB(-)CD27(-)) T cells and of activated CD11c(+)CD11bhigh cells to the lungs of aerosol-infected mice. For the first time, using in vivo analysis of transcriptome of inflammatory cytokines and chemokines of lung interstitial CD11c+ cells, we show that in a low-dose aerosol infection model, BCG::RD1 triggered an activation/inflammation program comparable to that induced by H37Rv while parental BCG, due to its overattenuation, did not initiate the activation program in lung interstitial CD11c+ cells. Thus, products encoded by the ESAT-6 secretion system 1 of M. tuberculosis profoundly modify the interaction between mycobacteria and the host innate and adaptive immune system. These modifications can explain the previously described improved protective capacity of BCG::RD1 vaccine candidate against M. tuberculosis challenge.

  10. WRAP Module 1 data management system (DMS) software design description (SDD)

    Energy Technology Data Exchange (ETDEWEB)

    Talmage, P.A.

    1995-03-17

    The Waste Receiving and Processing (WRAP) Module 1 Data Management System (DMS) System Design Description (SDD) describes the logical and physical architecture of the system. The WRAP 1 DMS SDD formally partitions the elements of the system described in the WRAP 1 DMS Software requirements specification into design objects and describes the key properties and relationships among the design objects and interfaces with external systems such as the WRAP Plant Control System (PCS). The WRAP 1 DMS SDD can be thought of as a detailed blueprint for implementation activities. The design descriptions contained within this document will describe, in detail, the software products that will be developed to assist the Project W-026, Waste Receiving and Processing Module 1, in their management functions. The WRAP 1 DMS is required to collect, store, and report data related to certification, tracking, packaging, repackaging, processing, and shipment of waste processed or stored at the WRAP 1 facility.

  11. WRAP Module 1 data management system (DMS) software design description (SDD)

    International Nuclear Information System (INIS)

    Talmage, P.A.

    1995-01-01

    The Waste Receiving and Processing (WRAP) Module 1 Data Management System (DMS) System Design Description (SDD) describes the logical and physical architecture of the system. The WRAP 1 DMS SDD formally partitions the elements of the system described in the WRAP 1 DMS Software requirements specification into design objects and describes the key properties and relationships among the design objects and interfaces with external systems such as the WRAP Plant Control System (PCS). The WRAP 1 DMS SDD can be thought of as a detailed blueprint for implementation activities. The design descriptions contained within this document will describe, in detail, the software products that will be developed to assist the Project W-026, Waste Receiving and Processing Module 1, in their management functions. The WRAP 1 DMS is required to collect, store, and report data related to certification, tracking, packaging, repackaging, processing, and shipment of waste processed or stored at the WRAP 1 facility

  12. 14 CFR Sec. 1-4 - System of accounts coding.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false System of accounts coding. Sec. 1-4 Section... General Accounting Provisions Sec. 1-4 System of accounts coding. (a) A four digit control number is assigned for each balance sheet and profit and loss account. Each balance sheet account is numbered...

  13. 48 CFR 970.5244-1 - Contractor purchasing system.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contractor purchasing... for Management and Operating Contracts 970.5244-1 Contractor purchasing system. As prescribed in 970.4403 insert the following clause: Contractor Purchasing System (AUG 2009) (a) General. The Contractor...

  14. Quantum SU(2|1) supersymmetric Calogero-Moser spinning systems

    Science.gov (United States)

    Fedoruk, Sergey; Ivanov, Evgeny; Lechtenfeld, Olaf; Sidorov, Stepan

    2018-04-01

    SU(2|1) supersymmetric multi-particle quantum mechanics with additional semi-dynamical spin degrees of freedom is considered. In particular, we provide an N=4 supersymmetrization of the quantum U(2) spin Calogero-Moser model, with an intrinsic mass parameter coming from the centrally-extended superalgebra \\widehat{su}(2\\Big|1) . The full system admits an SU(2|1) covariant separation into the center-of-mass sector and the quotient. We derive explicit expressions for the classical and quantum SU(2|1) generators in both sectors as well as for the total system, and we determine the relevant energy spectra, degeneracies, and the sets of physical states.

  15. Modifications of Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany based upon new version of Emergency Operating Procedures

    International Nuclear Information System (INIS)

    Aldorf, R.

    1997-01-01

    In the frame of 'living Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany Project' being performed by Nuclear Research Institute Rez during 1997 is planned to reflect on Probabilistic Safety Assessment-1 basis on impact of Emergency Response Guidelines (as one particular event from the list of other modifications) on Plant Safety. Following highlights help to orient the reader in main general aspects, findings and issues of the work that currently continues on. Older results of Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany have revealed that human behaviour during accident progression scenarios represent one of the most important aspects in plant safety. Current effort of Nuclear Power Plants Dukovany (Czech Republic) and Bohunice (Slovak Republic) is focussed on development of qualitatively new symptom-based Emergency Operating Procedures called Emergency Response Guidelines Supplier - Westinghouse Energy Systems Europe, Brussels works in cooperation with teams of specialist from both Nuclear Power Plants. In the frame of 'living Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany Project' being performed by Nuclear Research Institute Rez during 1997 is planned to prove on Probabilistic Safety Assessment -1 basis an expected - positive impact of Emergency Response Guidelines on Plant Safety, Since this contract is currently still in progress, it is possible to release only preliminary conclusions and observations. Emergency Response Guidelines compare to original Emergency Operating Procedures substantially reduce uncertainty of general human behaviour during plant response to an accident process. It is possible to conclude that from the current scope Probabilistic Safety Assessment Dukovany point of view (until core damage), Emergency Response Guidelines represent adequately wide basis for mitigating any initiating event

  16. UA1 experience with 3081/E systems

    International Nuclear Information System (INIS)

    Sphicas, P.A.

    1987-01-01

    A Harvard/MIT collaboration has built, with support from CERN, a 3081/E farm of two processors in Cambridge, MA. The farm was completed in the beginning of 1986. It has since been used for UA1 data analysis and two full production runs have been completed so far. The system will be upgraded in the near future: the number of 3081/E's will be increased to five, and a new IBM-VME interface developed at CERN will be installed. Similar farms have either already been built (CERN, 5 emulators) or have received approval (ROME, 2 emulators). They will also be used for production and analysis of UA1 data. An overview of the status, performance and future of these systems will be given. (orig.)

  17. Comparison of Knee and Ankle Dynamometry between NASA's X1 Exoskeleton and Biodex System 4

    Science.gov (United States)

    English, K. L.; Newby, N. J.; Hackney, K. J.; DeWitt, J. K.; Beck, C. E.; Rovekamp, R. N.; Rea, R. L.; Ploutz-Snyder, L. L.

    2014-01-01

    Pre- and post-flight dynamometry is performed on International Space Station crewmembers to characterize microgravity-induced strength changes. Strength is not assessed in flight due to hardware limitations and there is poor understanding of the time course of in-flight changes. PURPOSE: To assess the reliability of a prototype dynamometer, the X1 Exoskeleton (EXO) and its agreement with a Biodex System 4 (BIO). METHODS: Eight subjects (4 M/4 F) completed 2 counterbalanced testing sessions of knee extension/flexion (KE/KF), 1 with BIO and 1 with EXO, with repeated measures within each session in normal gravity. Test-retest reliability (test 1 and 2) and device agreement (BIO vs. EXO) were evaluated. Later, to assess device agreement for ankle plantarflexion (PF), 10 subjects (4 M/6 F) completed 3 test conditions (BIO, EXO, and BIOEXO); BIOEXO was a hybrid condition comprised of the Biodex dynamometer motor and the X1 footplate and ankle frame. Ankle comparisons were: BIO vs. BIOEXO (footplate differences), BIOEXO vs. EXO (motor differences), and BIO vs. EXO (all differences). Reliability for KE/KF was determined by intraclass correlation (ICC). Device agreement was assessed with: 1) repeated measures ANOVA, 2) a measure of concordance (rho), and 3) average difference. RESULTS: ICCs for KE/KF were 0.99 for BIO and 0.96 to 0.99 for EXO. Agreement was high for KE (concordance: 0.86 to 0.95; average differences: -7 to +9 Nm) and low to moderate for KF (concordance: 0.64 to 0.78; average differences: -4 to -29 Nm, Pexoskeleton to perform portable dynamometry for large muscle groups of the lower body.

  18. Organic Rankine kilowatt isotope power system. First annual summary report, August 1, 1975--August 1, 1976

    International Nuclear Information System (INIS)

    1976-01-01

    Sundstrand Energy Systems is developing a Kilowatt Isotope Power System (KIPS) directed toward satisfying the higher power requirements of satellites of the 1980's. The KIPS is a plutonium oxide fueled organic Rankine cycle turbine power system which will provide design output power in the range of 500 to 2000 W(e) with a minimum of system changes. Research progress is reported on Phase I comprising: (1) flight system conceptual design and ground demonstration; (2) flight system design and ground qualification; and (3) flight system production, acceptance testing and delivery. The principal objectives of Phase I are to: (1) conceptually design the flight system, (2) based on the flight system concept, design and build the ground demonstration system (GDS), (3) conduct performance and endurance testing using electric heaters to simulate the radioisotope heat source, (4) identify and initiate long lead development efforts required to achieve the initial flight qualification hardware availability date of April 1981, and (5) finalize the flight concept design and prepare the program plan for the Phase II effort

  19. Exploratory Shaft, Phase 1, Project B-314: Title 1 design report system design description

    International Nuclear Information System (INIS)

    Hanlen, D.F.

    1983-01-01

    The report describes the project and the project systems, the principal design bases, and principal hazards and project interfaces. This report also contains the Title 1 Estimate Summary. 5 figs., 8 tabs

  20. Assessing associations between the AURKA-HMMR-TPX2-TUBG1 functional module and breast cancer risk in BRCA1/2 mutation carriers.

    Directory of Open Access Journals (Sweden)

    Ignacio Blanco

    Full Text Available While interplay between BRCA1 and AURKA-RHAMM-TPX2-TUBG1 regulates mammary epithelial polarization, common genetic variation in HMMR (gene product RHAMM may be associated with risk of breast cancer in BRCA1 mutation carriers. Following on these observations, we further assessed the link between the AURKA-HMMR-TPX2-TUBG1 functional module and risk of breast cancer in BRCA1 or BRCA2 mutation carriers. Forty-one single nucleotide polymorphisms (SNPs were genotyped in 15,252 BRCA1 and 8,211 BRCA2 mutation carriers and subsequently analyzed using a retrospective likelihood approach. The association of HMMR rs299290 with breast cancer risk in BRCA1 mutation carriers was confirmed: per-allele hazard ratio (HR = 1.10, 95% confidence interval (CI 1.04-1.15, p = 1.9 x 10(-4 (false discovery rate (FDR-adjusted p = 0.043. Variation in CSTF1, located next to AURKA, was also found to be associated with breast cancer risk in BRCA2 mutation carriers: rs2426618 per-allele HR = 1.10, 95% CI 1.03-1.16, p = 0.005 (FDR-adjusted p = 0.045. Assessment of pairwise interactions provided suggestions (FDR-adjusted pinteraction values > 0.05 for deviations from the multiplicative model for rs299290 and CSTF1 rs6064391, and rs299290 and TUBG1 rs11649877 in both BRCA1 and BRCA2 mutation carriers. Following these suggestions, the expression of HMMR and AURKA or TUBG1 in sporadic breast tumors was found to potentially interact, influencing patients' survival. Together, the results of this study support the hypothesis of a causative link between altered function of AURKA-HMMR-TPX2-TUBG1 and breast carcinogenesis in BRCA1/2 mutation carriers.

  1. Ageing behaviour of [(n-1)/n] active redundancy systems

    International Nuclear Information System (INIS)

    Eid, M.Y.

    1995-01-01

    Ageing of systems becomes a real concern if intelligent maintenance is required. Determining the ageing behaviour of a system necessitate having a powerful calculating tool and knowing the ageing behaviour of the basic components of the systems. Consequently, time dependent failure rates are required for basic components and need to be determined for systems. As, this is the general problem in reliability analysis, only (n-1)/n active redundancy system will be examined in the paper. Systems with (n-1)/n active redundancy are commonly used in a wide range of engineering fields. This should permit a priori improving the system reliability. Still, a deeper analysis of the ageing behaviour of such systems may reveal some particular aspects. (authors). 2 refs., 5 figs

  2. HBA1C AND MEAN GLUCOSE DERIVED FROM SHORT-TERM CONTINUOUS GLUCOSE MONITORING ASSESSMENT DO NOT CORRELATE IN PATIENTS WITH HBA1C >8.

    Science.gov (United States)

    Yamada, Eijiro; Okada, Shuichi; Nakajima, Yasuyo; Bastie, Claire C; Vatish, Manu; Tagaya, Yuko; Osaki, Aya; Shimoda, Yoko; Shibusawa, Ryo; Saito, Tsugumichi; Okamura, Takashi; Ozawa, Atsushi; Yamada, Masanobu

    2017-01-01

    Optimum therapy for patients with diabetes depends on both acute and long-term changes in plasma glucose, generally assessed by glycated hemoglobin (HbA1c) levels. However, the correlation between HbA1c and circulating glucose has not been fully determined. Therefore, we carefully examined this correlation when glucose levels were assessed by continuous glucose monitoring (CGM). Fifty-one patients (70% female, 30% male) were examined; among them were 28 with type 1 diabetes and 23 with type 2 diabetes. Clinically determined HbA1c levels were compared with blood glucose determined by CGM during a short time period. Changes in HbA1c levels up to 8.0% showed a clear and statistically strong correlation (R = 0.6713; PHbA1c and CGM-assessed glucose levels in our patient population when HbA1c was >8.0%. Short-term CGM appears to be a good clinical indicator of long-term glucose control (HbA1c levels); however, cautions should be taken while interpreting CGM data from patients with HbA1c levels >8.0%. Over- or underestimation of the actual mean glucose from CGM data could potentially increase the risks of inappropriate treatment. As such, our results indicate that a more accurate analysis of CGM data might be useful to adequately tailor clinical treatments. ADAG = A1c-Derived Average Glucose CGM = continuous glucose monitoring %CV = percent coefficient of variation HbA1c = glycated hemoglobin.

  3. Commissioning the ATLAS Level-1 Central Trigger System

    CERN Document Server

    Sherman, Daniel

    2010-01-01

    The ATLAS Level-1 central trigger is a critical part of ATLAS operation. It receives the 40 MHz bunch clock from the LHC and distributes it to all sub-detectors. It initiates their read-out by forming the Level-1 Accept decision, which is based on information from the calorimeter and muon trigger processors and a variety of additional trigger inputs from detectors in the forward region. It also provides trigger summary information to the data acquisition system and the Level-2 trigger system. In this paper, we present the completion of the installed central trigger system, its performance during cosmic-ray data taking and the experience gained with triggering on the first LHC beams.

  4. Relativistic two-body system in (1+1)-dimensional QED. 1. On the circle S1

    International Nuclear Information System (INIS)

    Barut, A.O.; Saradzhev, F.M.

    1994-01-01

    From the coupled Maxwell-Dirac equations for two fermion fields Ψ 1 , Ψ 2 the authors derive a covariant two-body equation for the composite field Φ(x 1 , x 2 ) in configuration space which includes radiative self-energy effects. Both Coulomb gauge and covariant gauge have been used and their equivalence is proved. For the space S 1 the authors solve the two-body equation with mutual interactions exactly and obtain the mass spectrum in the case of massless fermions. 7 refs., 5 figs

  5. Tank waste remediation system retrieval and disposal mission phase 1 financial analysis

    International Nuclear Information System (INIS)

    Wells, M.W.

    1998-01-01

    The purpose of the Tank Waste Remediation System (TWRS) Retrieval and Disposal Mission Phase 1 Financial Analysis is to provide a quantitative and qualitative cost and schedule risk analysis of HNF-1946, Tank Waste Remediation System Retrieval and Disposal Mission Initial Updated Baseline (Swita et al. 1998). The Updated Baseline (Section 3.0) is compared to the current TWRS Project Multi-Year Work Plan (MYWP) for fiscal year (FY) 1998 and target budgets for FY 1999 through FY 2011 (Section 4.1). The analysis then evaluates the executability of HNF-1946 (Sections 4.2 through 4.5) and recommends a path forward for risk mitigation (Sections 4.6, 4.7, and 5.0). A sound systems engineering approach was applied to understand and analyze the Phase 1B Retrieval and Disposal mission. Program and Level 1 Logics were decomposed to Level 8 of the Work Breakdown Structure (WBS) where logic was detailed, scope was defined, detail durations and estimates prepared, and resource loaded schedules developed. Technical Basis Review (TBR) packages were prepared which include this information and, in addition, defined the enabling assumptions for each task, and the risks associated with performance. This process is discussed in Section 2.1. Detailed reviews at the subactivity within the Level 1 Logic TBR levels were conducted to provide the recommended solution to the Phase 1B Retrieval and Disposal Mission. Independent cost analysis and risk assessments were performed by members of the Lockheed Martin Hanford Corporation (LMHC) Business Management and Chief Financial Officer organization along with specialists in risk analysis from TRW, Inc. and Lockheed Martin Energy Systems. The process evaluated technical, schedule, and cost risk by category (program specific fixed and variable, integrated program, and programmatic) based on risk certainly from high probability well defined to very low probability that is not bounded or priceable as discussed in Section 2.2. The results have been

  6. The HIV-1 Rev/RRE system is required for HIV-1 5' UTR cis elements to augment encapsidation of heterologous RNA into HIV-1 viral particles

    Directory of Open Access Journals (Sweden)

    Ma Hong

    2011-06-01

    Full Text Available Abstract Background The process of HIV-1 genomic RNA (gRNA encapsidation is governed by a number of viral encoded components, most notably the Gag protein and gRNA cis elements in the canonical packaging signal (ψ. Also implicated in encapsidation are cis determinants in the R, U5, and PBS (primer binding site from the 5' untranslated region (UTR. Although conventionally associated with nuclear export of HIV-1 RNA, there is a burgeoning role for the Rev/RRE in the encapsidation process. Pleiotropic effects exhibited by these cis and trans viral components may confound the ability to examine their independent, and combined, impact on encapsidation of RNA into HIV-1 viral particles in their innate viral context. We systematically reconstructed the HIV-1 packaging system in the context of a heterologous murine leukemia virus (MLV vector RNA to elucidate a mechanism in which the Rev/RRE system is central to achieving efficient and specific encapsidation into HIV-1 viral particles. Results We show for the first time that the Rev/RRE system can augment RNA encapsidation independent of all cis elements from the 5' UTR (R, U5, PBS, and ψ. Incorporation of all the 5' UTR cis elements did not enhance RNA encapsidation in the absence of the Rev/RRE system. In fact, we demonstrate that the Rev/RRE system is required for specific and efficient encapsidation commonly associated with the canonical packaging signal. The mechanism of Rev/RRE-mediated encapsidation is not a general phenomenon, since the combination of the Rev/RRE system and 5' UTR cis elements did not enhance encapsidation into MLV-derived viral particles. Lastly, we show that heterologous MLV RNAs conform to transduction properties commonly associated with HIV-1 viral particles, including in vivo transduction of non-dividing cells (i.e. mouse neurons; however, the cDNA forms are episomes predominantly in the 1-LTR circle form. Conclusions Premised on encapsidation of a heterologous RNA into

  7. Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR): Part 1, Overview of NUCLARR data retrieval: User's guide

    International Nuclear Information System (INIS)

    Gilmore, W.E.; Gentillon, C.D.; Gertman, D.I.; Beers, G.H.; Galyean, W.J.; Gilbert, B.G.

    1988-06-01

    The Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) is an automated data base management system for processing and storing human error probability and hardware component failure data. The NUCLARR system software resides on an IBM (or compatible) personal micro-computer. NUCLARR can be used by the end user to furnish data inputs for both human and hardware reliability analysis in support of a variety of risk assessment activities. The NUCLARR system is documented in a five-volume series of reports. Volume IV of this series is the User's Guide for operating the NUCLARR software and is presented in three parts. This document, Part 1: Overview of NUCLARR Data Retrieval provides an introductory overview to the system's capabilities and procedures for data retrieval. The methods and criteria for selection of data sources and entering them into the NUCLARR system are also described in this document

  8. Suggesting a possible role of CA1 histaminergic system in harmane-induced amnesia.

    Science.gov (United States)

    Nasehi, Mohammad; Mashaghi, Elham; Khakpai, Fatemeh; Zarrindast, Mohammad-Reza

    2013-11-27

    A number of tremorogenic β-carboline alkaloids such as harmane are naturally present in the human food chain. They are derived from medicinal plants such as Peganum harmala that have been used as folk medicine in anticancer therapy. In the present study, effects of the histaminergic system of the dorsal hippocampus (CA1) on harmane-induced amnesia were examined. One-trial step-down was used to assess memory retention in adult male mice. The results showed that pre-training intra-CA1 administration of histamine (5μg/mouse), ranitidine (H2 receptor antagonist; at the doses of 0.25 and 0.5μg/mouse) and pyrilamine (H1 receptor antagonist; at the dose of 5μg/mouse) decreased memory formation. Pre-training intraperitoneal (i.p.) administration of harmane (12mg/kg) also decreased memory formation. Moreover, pre-training intra-CA1 injection of a sub-threshold dose of histamine (2.5μg/mouse) could reverse harmane (12mg/kg, i.p.)-induced impairment of memory. On the other hand, pre-training intra-CA1 injection of sub-threshold doses of ranitidine (0.0625μg/mouse) and pyrilamine (2.5μg/mouse) increased harmane-induced impairment of memory. In conclusion, the present findings suggest the involvement of the CA1 histaminergic system in harmane-induced impairment of memory formation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. MOESM1 of The effect of omega-3 fatty acids on central nervous system remyelination in fat-1 mice

    OpenAIRE

    Siegert, Elise; Paul, Friedemann; Rothe, Michael; Weylandt, Karsten

    2017-01-01

    Additional file 1: Figure S1. Experimental groups. In order to assess the impact of n-3 versus n-6 PUFAs on de- and remyelination, animals were divided into six experimental groups. Ten wt and twelve fat-1 animals were put on a 0.2 % cuprizone diet for five weeks, while four wt and four fat-1 animals were fed a normal diet instead. At the end of the five weeks both control groups and the five wt and six fat-1 animals that had been fed cuprizone were sacrificed. The remaining animals were allo...

  10. Performance of an in-house human immunodeficiency virus type 1 genotyping system for assessment of drug resistance in Cuba.

    Directory of Open Access Journals (Sweden)

    Yoan Alemán

    Full Text Available As commercial human immunodeficiency virus type 1 drug resistance assays are expensive, they are not commonly used in resource-limited settings. Hence, a more affordable in-house procedure was set up taking into account the specific epidemiological and economic circumstances of Cuba. The performance characteristics of the in-house assay were evaluated using clinical samples with various subtypes and resistance patterns. The lower limit of amplification was determined on dilutions series of 20 clinical isolates and ranged from 84 to 529 RNA copies/mL. For the assessment of trueness, 14 clinical samples were analyzed and the ViroSeq HIV-1 Genotyping System v2.0 was used as the reference standard. The mean nucleotide sequence identity between the two assays was 98.7% ± 1.0. Additionally, 99.0% of the amino acids at drug resistance positions were identical. The sensitivity and specificity in detecting drug resistance mutations was respectively 94.1% and 99.5%. Only few discordances in drug resistance interpretation patterns were observed. The repeatability and reproducibility were evaluated using 10 clinical samples with 3 replicates per sample. The in-house test was very precise as nucleotide sequence identity among paired nucleotide sequences ranged from 98.7% to 99.9%. The acceptance criteria were met by the in-house test for all performance characteristics, demonstrating a high degree of accuracy. Subsequently, the applicability in routine clinical practice was evaluated on 380 plasma samples. The amplification success rate was 91% and good quality consensus sequences encoding the entire protease and the first 335 codons in reverse transcriptase could be obtained for 99% of the successful amplicons. The reagent cost per sample using the in-house procedure was around € 80 per genotyping attempt. Overall, the in-house assay provided good results, was feasible with equipment and reagents available in Cuba and was half as expensive as commercial

  11. Molecular dissection of the response of the rice Systemic Acquired Resistance Deficient 1 (SARD1) gene to different types of ionizing radiation.

    Science.gov (United States)

    Jung, In Jung; Hwang, Jung Eun; Han, Sung Min; Kim, Dong Sub; Ahn, Joon-Woo; Choi, Hong-Il; Kwon, Soon-Jae; Kang, Si-Yong; Kim, Jin-Baek

    2017-07-01

    Exposure to ionizing radiation induces plant defenses by regulating the expression of response genes. The systemic acquired resistance deficient 1 (SARD1) is a key gene in plant defense response. In this study, the function of Oryza sativa SARD1 (OsSARD1) was investigated after exposure of seeds/plants to ionizing radiation, jasmonic acid (JA) or salicylic acid (SA). Rice seeds exposed to two types of ionizing radiations (gamma ray [GR] and ion beam [IB]) were analyzed by quantitative reverse transcription PCR (qRT-PCR) to identify the genes that are altered in response to ionizing radiation. Then, OsSARD1-overexpressing homozygous Arabidopsis plants were generated to assess the effects of OsSARD1 in the response to irradiation. The phenotypes of these transgenic plants, as well as control plants, were monitored after GR irradiation at doses of 200 and 300 Gray (Gy). The OsSARD1 transcript was strongly downregulated after exposure to GR and IB irradiation. Previous phylogenetic analysis showed that the Arabidopsis SARD1 (AtSARD1) protein is closely related to Arabidopsis calmodulin-binding protein 60g (AtCBP60g), which is known to be required for activation of SA biosynthesis. In this study, phylogenetic analysis showed that OsSARD1 was grouped with AtSARD1. The OsSARD1 gene was induced after exposure to SA and JA. The biological phenotype of OsSARD1-overexpressing Arabidopsis plants was examined. OsSARD1-overexpressing plants displayed resistance to GR; in comparison with wild-type plants, the height and weight of OsSARD1-overexpressing plants were significantly greater after GR irradiation. In addition, OsSARD1 protein was abundantly accumulated in the nucleus. The results indicate that OsSARD1 plays an important role in the regulation of the defense responses to GR and IB irradiation and exhibits phytohormone induced expression.

  12. Formation of TRAPPIST-1 and other compact systems

    NARCIS (Netherlands)

    Ormel, C.W.; Liu, B.; Schoonenberg, D.

    TRAPPIST-1 is a nearby 0.08 M⊙ M-star that was recentlyfound to harbor a planetary system of at least seven Earth-sizedplanets, all within 0.1 au. The configuration confounds theorists as theplanets are not easily explained by either in situ or migration models.In this paper we present a scenario

  13. Assessment System for Aircraft Noise (ASAN) Citation Database. Volume 1

    Science.gov (United States)

    1989-12-01

    kills "). Most researchers would take an opposing position on the given research topic. 2 Some elements of the publication are con-r ,ersial 14 4. Report...01.02.21.09.00.00 Mockingbirds 01.07.22.06.00.00 Mojarras 01.07.24.00.00.00 Molas 01.01.03.03.00.00 Moles 02.00.00.00.00.00 Mollusca 02.00.00.00.00.00...Bluebirds ...Robins ...Sialia ...Turdus Ol.02.2l.09.OO.OO ... Catbirds ... Mimidae -. Mockingbirds ... Thrashers 01.02.21:1.0.00. ... Motacillidae

  14. Development of Neutron Imaging System for Neutron Tomography at Thai Research Reactor TRR-1/M1

    Science.gov (United States)

    Wonglee, S.; Khaweerat, S.; Channuie, J.; Picha, R.; Liamsuwan, T.; Ratanatongchai, W.

    2017-09-01

    The neutron imaging is a powerful non-destructive technique to investigate the internal structure and provides the information which is different from the conventional X-ray/Gamma radiography. By reconstruction of the obtained 2-dimentional (2D) images from the taken different angle around the specimen, the tomographic image can be obtained and it can provide the information in more detail. The neutron imaging system at Thai Research Reactor TRR-1/M1 of Thailand Institute of Nuclear Technology (Public Organization) has been developed to conduct the neutron tomography since 2014. The primary goal of this work is to serve the investigation of archeological samples, however, this technique can also be applied to various fields, such as investigation of industrial specimen and others. This research paper presents the performance study of a compact neutron camera manufactured by Neutron Optics such as speed and sensitivity. Furthermore, the 3-dimentional (3D) neutron image was successfully reconstructed at the developed neutron imaging system of TRR-1/M1.

  15. Assessment of the turbine trip transient in Cofrentes NPP with TRAC-BF1

    International Nuclear Information System (INIS)

    Castrillo, F.; Gomez, A.; Gallego, I.

    1993-06-01

    This report presents the results of the assessment of TRAC-BF1 (G1-J1) code with the model of C. N. Cofrentes for simulation of the transient originated by the manual trip of the main turbine. C. N. Cofrentes is a General Electric designed BWR/6 plant, with a nominal core thermal power of 2894 Mwt, in commercial operation since 1985, owned and operated by Hidroelectrica Espanola, S. A. The plant incorporates all the characteristics of BWR/6 reactors, with two turbine driven FW pumps. As a result of this assessment a model of C. N. Cofrentes has been developed for TRAC-BF1 that fairly reproduces operational transient behavior of the plant. A special purpose code was generated to obtain reactivity coefficients, as required by TRAC-BF1, from the 3D simulator

  16. [Construction of a system for proper TS-1 application].

    Science.gov (United States)

    Azuma, Sayaka; Morimoto, Shigefumi; Kagawa, Kunihiko; Katada, Yoshinori; Hasegawa, Kenji; Tabuse, Katsuyoshi

    2010-03-01

    TS-1 is an oral anti-tumor drug, which contains 5-chloro-2, 4-dihydroxypyridine (CDHP), a compound mainly excreted in urine. Since the CDHP concentration is increased among patients with impaired renal function, the frequency of side effects of TS-1 increases in such patients. Therefore, we constructed a computer-aided system that enables prompt monitoring of creatinine clearance (Ccr) calculated from the serum creatinine levels of patients prescribed TS-1 at the time pharmacists prepare the medicine. With this system, we found two cases who were prescribed TS-1, despite their decreased Ccr. One was a patient whose estimated Ccr was less than 30 mL/min/m2. With such renal malfunction, pharmacokinetics of the drug was considerably changed compared with normal control, and the dosage should be reduced. The other case presented with severe jaundice and had only a mild decrease of renal function (Ccr: 50 mL/min/m2). So we measured the concentration of uracil in the urine and performed a drug lymphocyte stimulation test for further investigation of concomitant affecting factors. Our system is useful because it can show pharmacists both the dosage TS-1 patients take and their renal function at a glance in real time. This system can be adapted for every medicine which might accumulate in patients with renal dysfunction.

  17. ON-BOARD COMPUTER SYSTEM FOR KITSAT-1 AND 2

    Directory of Open Access Journals (Sweden)

    H. S. Kim

    1996-06-01

    Full Text Available KITSAT-1 and 2 are microsatellites weighting 50kg and all the on-board data are processed by the on-board computer system. Hence, these on-board computers require to be highly reliable and be designed with tight power consumption, mass and size constraints. On-board computer(OBC systems for KITSAT-1 and 2 are also designed with a simple flexible hardware for reliability and software takes more responsibility than hardware. KITSAT-1 and 2 on-board computer system consist of OBC 186 as the primary OBC and OBC80 as its backup. OBC186 runs spacecraft operating system (SCOS which has real-time multi-tasking capability. Since their launch, OBC186 and OBC80 have been operating successfully until today. In this paper, we describe the development of OBC186 hardware and software and analyze its in-orbit operation performance.

  18. Ada Compiler Validation Summary Report: Certificate Number: 940305W1. 11335 TLD Systems, Ltd. TLD Comanche VAX/i960 Ada Compiler System, Version 4.1.1 VAX Cluster under VMS 5.5 = Tronix JIAWG Execution Vehicle (i960MX) under TLD Real Time Executive, Version 4.1.1

    Science.gov (United States)

    1994-03-14

    Comanche VAX/i960 Ada Compiler System, Version 4.1.1 Host Computer System: Digital Local Area Network VAX Cluster executing on (2) MicroVAX 3100 Model 90...31 $MAX DIGITS 15 SmNx INT 2147483647 $MAX INT PLUS_1 2147483648 $MIN IN -2_147483648 A-3 MACR PARAMEERIS $NAME NO SUCH INTEGER TYPE $NAME LIST...nested generlcs are Supported and generics defined in libary units are pexitted. zt is not possible to pen ore a macro instantiation for a generic I

  19. Conceptual design and systems analysis of photovoltaic power systems. Volume III(1). Technology

    Energy Technology Data Exchange (ETDEWEB)

    Pittman, P.F.

    1977-05-01

    Conceptual designs were made and analyses were performed on three types of solar photovoltaic power systems. Included were Residential (1 to 10 kW), Intermediate (0.1 to 10 MW), and Central (50 to 1000 MW) Power Systems to be installed in the 1985 to 2000 time period. Subsystem technology presented here includes: insolation, concentration, silicon solar cell modules, CdS solar cell module, array structure, battery energy storage, power conditioning, residential power system architectural designs, intermediate power system structural design, and central power system facilities and site survey.

  20. Electronics and instrumentation for the SST-1 superconducting magnet system

    International Nuclear Information System (INIS)

    Khristi, Yohan; Pradhan, Subrata; Varmora, Pankaj; Banaudha, Moni; Praghi, Bhadresh R.; Prasad, Upendra

    2015-01-01

    Steady State Superconducting Tokamak-1 (SST-1) at Institute for Plasma Research (IPR), India is now in operation phase. The SST-1 magnet system consists of sixteen superconducting (SC), D-shaped Toroidal Field (TF) coils and nine superconducting Poloidal Field (PF) coils together with a pair of resistive PF coils, inside the vacuum vessel of SST-1. The magnets were cooled down to 4.5 K using either supercritical or two-phase helium, after which they were charged up to 10 kA of transport current. Precise quench detection system, cryogenic temperature, magnetic field, strain, displacement, flow and pressure measurements in the Superconducting (SC) magnet were mandatory. The Quench detection electronics required to protect the SC magnets from the magnet Quench therefore system must be reliable and prompt to detect the quench from the harsh tokamak environment and high magnetic field interference. A ∼200 channels of the quench detection system for the TF magnet are working satisfactorily with its design criteria. Over ∼150 channels Temperature measurement system was implemented for the several locations in the magnet and hydraulic circuits with required accuracy of 0.1K at bellow 30K cryogenic temperature. Whereas the field, strain and displacement measurements were carried out at few predefined locations on the magnet. More than 55 channels of Flow and pressure measurements are carried out to know the cooling condition and the mass flow of the liquid helium (LHe) coolant for the SC Magnet system. This report identifies the different in-house modular signal conditioning electronics and instrumentation systems, calibration at different levels and the outcomes for the SST-1 TF magnet system. (author)

  1. Generation of a vector system facilitating cloning of DMBT1 variants and recombinant expression of functional full-length DMBT1

    DEFF Research Database (Denmark)

    End, Caroline; Lyer, Stefan; Renner, Marcus

    2005-01-01

    of a vector system that facilitates cloning of DMBT1 variants. We demonstrate applicability of the vector system by expression of the largest DMBT1 variant in a tetracycline-inducible mammalian expression system using the Chinese hamster ovary cell line. Yields up to 30 mg rDMBT1 per litre of cell culture......Deleted in malignant brain tumours 1 (DMBT1) codes for a approximately 340kDa glycoprotein with highly repetitive scavenger receptor cysteine-rich (SRCR) domains. DMBT1 was implicated in cancer, defence against viral and bacterial infections, and differentiation of epithelial cells. Recombinant...... yields, and protein preparations which may substantially vary due to differential processing and genetic polymorphism, all of which impedes functional research on DMBT1. Cloning of DMBT1 cDNAs is hampered because of the size and the 13 highly homologous SRCR exons. In this study, we report on the setup...

  2. Nitrogen Gas Heating and Supply System for SST-1 Tokamak

    International Nuclear Information System (INIS)

    Khan, Ziauddin; Pathan, Firozkhan; Paravastu, Yuvakiran; George, Siju; Ramesh, Gattu; Bindu, Hima; Raval, Dilip C.; Thankey, Prashant; Dhanani, Kalpesh; Pradhan, Subrata

    2013-01-01

    Steady State Tokamak (SST-1) vacuum vessel baking as well as baking of the first wall components of SST-1 are essential to plasma physics experiments. Under a refurbishment spectrum of SST-1, the nitrogen gas heating and supply system has been fully refurbished. The SST-1 vacuum vessel consists of ultra-high vacuum (UHV) compatible eight modules and eight sectors. Rectangular baking channels are embedded on each of them. Similarly, the SST-1 plasma facing components (PFC) are comprised of modular graphite diverters and movable graphite based limiters. The nitrogen gas heating and supply system would bake the plasma facing components at 350°C and the SST-1 vacuum vessel at 150°C over an extended duration so as to remove water vapour and other absorbed gases. An efficient PLC based baking facility has been developed and implemented for monitoring and control purposes. This paper presents functional and operational aspects of a SST-1 nitrogen gas heating and supply system. Some of the experimental results obtained during the baking of SST-1 vacuum modules and sectors are also presented here. (fusion engineering)

  3. Assessment of Analytic Morphograph CF-1 manufactured by Kent Laboratory Services Ltd

    International Nuclear Information System (INIS)

    1983-10-01

    An addendum is presented covering the assessment of an Analytic Morphograph CF-1 which incorporates the design modifications which arose out of the initial assessment in the main DHSS report. The assessment, made at Booth Hall Children's Hospital, evaluated modifications including X-ray field size adjustment, improved patient supports, operator's protective screen, film screens and grid and film marking. (U.K.)

  4. Measurements of Forbush decreases at Mars: both by MSL on ground and by MAVEN in orbit

    Science.gov (United States)

    Guo, Jingnan; Lillis, Robert; Wimmer-Schweingruber, Robert F.; Zeitlin, Cary; Simonson, Patrick; Rahmati, Ali; Posner, Arik; Papaioannou, Athanasios; Lundt, Niklas; Lee, Christina O.; Larson, Davin; Halekas, Jasper; Hassler, Donald M.; Ehresmann, Bent; Dunn, Patrick; Böttcher, Stephan

    2018-04-01

    The Radiation Assessment Detector (RAD), on board Mars Science Laboratory's (MSL) Curiosity rover, has been measuring ground level particle fluxes along with the radiation dose rate at the surface of Mars since August 2012. Similar to neutron monitors at Earth, RAD sees many Forbush decreases (FDs) in the galactic cosmic ray (GCR) induced surface fluxes and dose rates. These FDs are associated with coronal mass ejections (CMEs) and/or stream/corotating interaction regions (SIRs/CIRs). Orbiting above the Martian atmosphere, the Mars Atmosphere and Volatile EvolutioN (MAVEN) spacecraft has also been monitoring space weather conditions at Mars since September 2014. The penetrating particle flux channels in the solar energetic particle (SEP) instrument onboard MAVEN can also be employed to detect FDs. For the first time, we study the statistics and properties of a list of FDs observed in-situ at Mars, seen both on the surface by MSL/RAD and in orbit detected by the MAVEN/SEP instrument. Such a list of FDs can be used for studying interplanetary coronal mass ejections (ICME) propagation and SIR evolution through the inner heliosphere. The magnitudes of different FDs can be well-fitted by a power-law distribution. The systematic difference between the magnitudes of the FDs within and outside the Martian atmosphere may be mostly attributed to the energy-dependent modulation of the GCR particles by both the pass-by ICMEs/SIRs and the Martian atmosphere.

  5. Part 1: diagnosis and monitoring

    Directory of Open Access Journals (Sweden)

    Dorota Krasowska

    2017-11-01

    Full Text Available Systemic sclerosis is an immune-mediated disease characterized by a chronic and progressive course. It often leads to multiorgan failure and patient disability, and contributes to significant reduction in the quality of life. Systemic sclerosis affects the skin, subcutaneous tissue, muscles, osteoarticular system and internal organs. The complexity and diversity of clinical presentations require an individual approach and multidisciplinary collaboration both at the stage of diagnosis and treatment. Critical factors in systemic sclerosis include early diagnosis, assessment of internal organ involvement, identification of patients at potential risk of organ complications, assessment of disease dynamics and activity, and implementation of optimal therapy. Part 1 presents current recommendations for the diagnostics and monitoring of patients with systemic sclerosis. Attention is given to classification criteria, clinical forms of systemic sclerosis, assessment of skin thickness and systemic sclerosis microangiopathy, significance of antinuclear antibodies, diagnosis of interstitial lung disease and pulmonary arterial hypertension, renal crisis and cardiac abnormalities, and evaluation of the gastrointestinal tract and osteoarticular and muscular systems.

  6. The UA1 VME data acquisition system

    International Nuclear Information System (INIS)

    Cittolin, S.

    1988-01-01

    The data acquisition system of a large-scale experiment such as UA1, running at the CERN proton-antiproton collider, has to cope with very high data rates and to perform sophisticated triggering and filtering in order to analyze interesting events. These functions are performed by a variety of programmable units organized in a parallel multiprocessor system whose central architecture is based on the industry-standard VME/VMXbus. (orig.)

  7. Suppression of lipin-1 expression increases monocyte chemoattractant protein-1 expression in 3T3-L1 adipocytes

    International Nuclear Information System (INIS)

    Takahashi, Nobuhiko; Yoshizaki, Takayuki; Hiranaka, Natsumi; Suzuki, Takeshi; Yui, Tomoo; Akanuma, Masayasu; Oka, Kazuya; Kanazawa, Kaoru; Yoshida, Mika; Naito, Sumiyoshi; Fujiya, Mikihiro; Kohgo, Yutaka; Ieko, Masahiro

    2011-01-01

    Highlights: ► Lipin-1 affects lipid metabolism, adipocyte differentiation, and transcription. ► Adipose lipin-1 expression is reduced in obesity. ► Lipin-1 depletion using siRNA in 3T3-L1 adipocytes increased MCP-1 expression. ► Lipin-1 is involved in adipose inflammation. -- Abstract: Lipin-1 plays a crucial role in the regulation of lipid metabolism and cell differentiation in adipocytes. Expression of adipose lipin-1 is reduced in obesity, and metabolic syndrome. However, the significance of this reduction remains unclear. This study investigated if and how reduced lipin-1 expression affected metabolism. We assessed mRNA expression levels of various genes related to adipocyte metabolism in lipin-1-depleted 3T3-L1 adipocytes by introducing its specific small interfering RNA. In lipin-1-depleted adipocytes, mRNA and protein expression levels of monocyte chemoattractant protein-1 (MCP-1) were significantly increased, although the other genes tested were not altered. The conditioned media from the cells promoted monocyte chemotaxis. The increase in MCP-1 expression was prevented by treatment with quinazoline or salicylate, inhibitors of nuclear factor-κB activation. Because MCP-1 is related to adipose inflammation and systemic insulin resistance, these results suggest that a reduction in adipose lipin-1 in obesity may exacerbate adipose inflammation and metabolism.

  8. Suppression of lipin-1 expression increases monocyte chemoattractant protein-1 expression in 3T3-L1 adipocytes

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Nobuhiko, E-mail: ntkhs@hoku-iryo-u.ac.jp [Department of Internal Medicine, School of Dentistry, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Toubetsu, Hokkaido 061-0023 (Japan); Division of Gastroenterology and Hematology/Oncology, Department of Medicine, Asahikawa Medical University, 2-1-1-1 Midorigaoka-Higashi, Asahikawa, Hokkaido 078-8510 (Japan); Yoshizaki, Takayuki [Innovation Center, Kagoshima University, 1-21-40 Korimoto, Kagoshima 890-0065 (Japan); Hiranaka, Natsumi; Suzuki, Takeshi [Department of Internal Medicine, School of Dentistry, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Toubetsu, Hokkaido 061-0023 (Japan); Yui, Tomoo; Akanuma, Masayasu; Oka, Kazuya [Department of Fixed Prosthodontics and Oral Implantology, School of Dentistry, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Toubetsu, Hokkaido 061-0023 (Japan); Kanazawa, Kaoru [Department of Dental Anesthesiology, School of Dentistry, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Toubetsu, Hokkaido 061-0023 (Japan); Yoshida, Mika; Naito, Sumiyoshi [Department of Clinical Laboratory, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Toubetsu, Hokkaido 061-0023 (Japan); Fujiya, Mikihiro; Kohgo, Yutaka [Division of Gastroenterology and Hematology/Oncology, Department of Medicine, Asahikawa Medical University, 2-1-1-1 Midorigaoka-Higashi, Asahikawa, Hokkaido 078-8510 (Japan); Ieko, Masahiro [Department of Internal Medicine, School of Dentistry, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Toubetsu, Hokkaido 061-0023 (Japan)

    2011-11-11

    Highlights: Black-Right-Pointing-Pointer Lipin-1 affects lipid metabolism, adipocyte differentiation, and transcription. Black-Right-Pointing-Pointer Adipose lipin-1 expression is reduced in obesity. Black-Right-Pointing-Pointer Lipin-1 depletion using siRNA in 3T3-L1 adipocytes increased MCP-1 expression. Black-Right-Pointing-Pointer Lipin-1 is involved in adipose inflammation. -- Abstract: Lipin-1 plays a crucial role in the regulation of lipid metabolism and cell differentiation in adipocytes. Expression of adipose lipin-1 is reduced in obesity, and metabolic syndrome. However, the significance of this reduction remains unclear. This study investigated if and how reduced lipin-1 expression affected metabolism. We assessed mRNA expression levels of various genes related to adipocyte metabolism in lipin-1-depleted 3T3-L1 adipocytes by introducing its specific small interfering RNA. In lipin-1-depleted adipocytes, mRNA and protein expression levels of monocyte chemoattractant protein-1 (MCP-1) were significantly increased, although the other genes tested were not altered. The conditioned media from the cells promoted monocyte chemotaxis. The increase in MCP-1 expression was prevented by treatment with quinazoline or salicylate, inhibitors of nuclear factor-{kappa}B activation. Because MCP-1 is related to adipose inflammation and systemic insulin resistance, these results suggest that a reduction in adipose lipin-1 in obesity may exacerbate adipose inflammation and metabolism.

  9. Expression and Characterization of Human β-1, 4-Galactosyltransferase 1 (β4GalT1) Using Silkworm–Baculovirus Expression System

    KAUST Repository

    Morokuma, Daisuke

    2017-03-24

    Baculovirus expression vector system (BEVS) is widely known as a mass-production tool to produce functional recombinant glycoproteins except that it may not be always suitable for medical practice due to the differences in the structure of N-linked glycans between insects and mammalian. Currently, various approaches have been reported to alter N-linked glycan structures of glycoproteins derived from insects into terminally sialylated complex-type N-glycans. In the light of those studies, we also proposed in vitro maturation of N-glycan with mass-produced and purified glycosyltransferases by silkworm–BEVS. β-1,4-Galactosyltransferase 1 (β4GalT1) is known as one of type II transmembrane enzymes that transfer galactose in a β-1, 4 linkage to accepter sugars, and a key enzyme for further sialylation of N-glycans. In this study, we developed a large-scale production of recombinant human β4GalT1 (rhβ4GalT1) with N- or C-terminal tags in silkworm–BEVS. We demonstrated that rhβ4GalT1 is N-glycosylated and without mucin-type glycosylation. Interestingly, we found that purified rhβ4GalT1 from silkworm serum presented higher galactosyltransferase activity than that expressed from cultured mammalian cells. We also validated the UDP-galactose transferase activity of produced rhβ4GalT1 proteins by using protein subtracts from silkworm silk gland. Taken together, rhβ4GalT1 from silkworms can become a valuable tool for producing high-quality recombinant glycoproteins with mammalian-like N-glycans.

  10. Description of surface systems. Preliminary site description. Forsmark area Version 1.2

    Energy Technology Data Exchange (ETDEWEB)

    Lindborg, Tobias [ed.

    2005-06-01

    Swedish Nuclear Fuel and Waste Management Co (SKB) started site investigations for a deep repository for spent nuclear fuel in 2002 at two different sites in Sweden, Forsmark and Oskarshamn. The investigations should provide necessary information for a license application aimed at starting underground exploration. For this reason, ecosystem data need to be interpreted and assessed into site descriptive models, which in turn are used for safety assessment studies and for environmental impact assessment. Descriptions of the surface system are also needed for further planning of the site investigations. This report describes the surface ecosystems of the Forsmark site (e.g. hydrology, Quaternary deposits, chemistry, vegetation, animals and the human land use). The ecosystem description is an integration of the site and its regional setting, covering the current state of the biosphere as well as the ongoing natural processes affecting the longterm development. Improving the descriptions is important during both the initial and the complete site investigation phase. Before starting of the initial phase in Forsmark, version 0 of the site descriptive model was developed. The results of the initial site investigation phase is compiled into a preliminary site description of Forsmark (version 1.2) in June 2005. This report provides the major input and background to the biosphere description, in the 1.2 version of the Forsmark site description. The basis for this interim version is quality-assured field data from the Forsmark sub area and regional area, available in the SKB SICADA, and GIS data bases as of July 31th 2004 as well as version 1.1 of the Site Descriptive Model. To achieve an ecosystem site description there is a need to develop discipline-specific models by interpreting and analysing primary data. The different discipline-specific models are then integrated into a system describing interactions and flows and stocks of matter between and within functional units in

  11. Description of surface systems. Preliminary site description. Forsmark area Version 1.2

    International Nuclear Information System (INIS)

    Lindborg, Tobias

    2005-06-01

    Swedish Nuclear Fuel and Waste Management Co (SKB) started site investigations for a deep repository for spent nuclear fuel in 2002 at two different sites in Sweden, Forsmark and Oskarshamn. The investigations should provide necessary information for a license application aimed at starting underground exploration. For this reason, ecosystem data need to be interpreted and assessed into site descriptive models, which in turn are used for safety assessment studies and for environmental impact assessment. Descriptions of the surface system are also needed for further planning of the site investigations. This report describes the surface ecosystems of the Forsmark site (e.g. hydrology, Quaternary deposits, chemistry, vegetation, animals and the human land use). The ecosystem description is an integration of the site and its regional setting, covering the current state of the biosphere as well as the ongoing natural processes affecting the longterm development. Improving the descriptions is important during both the initial and the complete site investigation phase. Before starting of the initial phase in Forsmark, version 0 of the site descriptive model was developed. The results of the initial site investigation phase is compiled into a preliminary site description of Forsmark (version 1.2) in June 2005. This report provides the major input and background to the biosphere description, in the 1.2 version of the Forsmark site description. The basis for this interim version is quality-assured field data from the Forsmark sub area and regional area, available in the SKB SICADA, and GIS data bases as of July 31th 2004 as well as version 1.1 of the Site Descriptive Model. To achieve an ecosystem site description there is a need to develop discipline-specific models by interpreting and analysing primary data. The different discipline-specific models are then integrated into a system describing interactions and flows and stocks of matter between and within functional units in

  12. Results of the Level 1 probabilistic risk assessment (PRA) of internal events for heavy water production reactors

    International Nuclear Information System (INIS)

    Tinnes, S.P.; Cramer, D.S.; Logan, V.E.; Topp, S.V.; Smith, J.A.; Brandyberry, M.D.

    1990-01-01

    A full-scope probabilistic risk assessment (PRA) is being performed for the Savannah River site (SRS) production reactors. The Level 1 PRA for the K Reactor has been completed and includes the assessment of reactor systems response to accidents and estimates of the severe core melt frequency (SCMF). The internal events spectrum includes those events related directly to plant systems and safety functions for which transients or failures may initiate an accident. The SRS PRA has three principal objectives: improved understanding of SRS reactor safety issues through discovery and understanding of the mechanisms involved. Improved risk management capability through tools for assessing the safety impact of both current standard operations and proposed revisions. A quantitative measure of the risks posed by SRS reactor operation to employees and the general public, to allow comparison with declared goals and other societal risks

  13. Efficient Genome Editing in Chicken DF-1 Cells Using the CRISPR/Cas9 System

    Directory of Open Access Journals (Sweden)

    Yichun Bai

    2016-04-01

    Full Text Available In recent years, genome engineering technology has provided unprecedented opportunities for site-specific modification of biological genomes. Clustered regularly interspaced short palindromic repeats (CRISPR/CRISPR-associated (Cas 9 is one such means that can target a specific genome locus. It has been applied in human cells and many other organisms. Meanwhile, to efficiently enrich targeted cells, several surrogate systems have also been developed. However, very limited information exists on the application of CRISPR/Cas9 in chickens. In this study, we employed the CRISPR/Cas9 system to induce mutations in the peroxisome proliferator-activated receptor-γ (PPAR-γ, ATP synthase epsilon subunit (ATP5E, and ovalbumin (OVA genes in chicken DF-1 cells. The results of T7E1 assays showed that the mutation rate at the three different loci was 0.75%, 0.5%, and 3.0%, respectively. In order to improve the mutation efficiency, we used the PuroR gene for efficient enrichment of genetically modified cells with the surrogate reporter system. The mutation rate, as assessed via the T7E1 assay, increased to 60.7%, 61.3%, and 47.3%, and subsequent sequence analysis showed that the mutation efficiency increased to 94.7%, 95%, and 95%, respectively. In addition, there were no detectable off-target mutations in three potential off-target sites using the T7E1 assay. As noted above, the CRISPR/Cas9 system is a robust tool for chicken genome editing.

  14. 48 CFR 1.105-1 - Publication and code arrangement.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Publication and code arrangement. 1.105-1 Section 1.105-1 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.105-1 Publication and code...

  15. PICK1 expression in the Drosophila central nervous system primarily occurs in the neuroendocrine system

    DEFF Research Database (Denmark)

    Jansen, Anna M; Nässel, Dick R; Madsen, Kenneth L

    2009-01-01

    in the adult and larval Drosophila central nervous system. PICK1 was found in cell bodies in the subesophageal ganglion, the antennal lobe, the protocerebrum, and the neuroendocrine center pars intercerebralis. The cell types that express PICK1 were identified using GAL4 enhancer trap lines. The PICK1...... (AMPA) receptor subunit GluR2 and the dopamine transporter. PICK1 is strongly implicated in GluR2 trafficking and synaptic plasticity. In mammals, PICK1 has been characterized extensively in cell culture studies. To study PICK1 in an intact system, we characterized PICK1 expression immunohistochemically...... neurons in the neuroendocrine system, which express the transcription factor DIMM and the amidating enzyme peptidylglycine-alpha-hydroxylating monooxygenase (PHM). The PICK1-positive cells include neurosecretory cells that produce the insulin-like peptide dILP2. PICK1 expression in insulin-producing cells...

  16. ID-1 mass storage system for mainframe by using FDDI network

    International Nuclear Information System (INIS)

    Morita, Y.; Fujii, H.; Inoue, E.; Kodama, H. Manabe, A.; Miyamoto, A.; Nomachi, M.; Watase, Y.; Yasu, Y.

    1994-01-01

    The authors have developed an ID-1 mass storage system as a distributed data server for Fujitsu mainframe computers. The system consists of a SONY ID-1 recorder DIR-1000, a tape robot system DMS-24 and a SCSI-II interface DFC-1500, which are connected to Spar Station 10 with an FDDI interface. The maximum speed of 7.5 Mbytes/sec is achieved for data transfer between Sparc Station 10 memory and DIR-1000 with a buffer size of 1 Mbytes. The system has been used successfully since last October to migrate more than 1 Tbytes data

  17. Model summary report for the safety assessment SFR 1 SAR-08

    Energy Technology Data Exchange (ETDEWEB)

    2008-03-15

    This document is the model summary report for the safety assessment SFR 1 SAR-08. In the report, the quality assurance measures conducted for the assessment codes are presented together with the chosen methodology. In the safety assessment SFR1 SAR-08, a number of different computer codes are used. In order to better understand how these codes are related an Assessment Model Flowchart, AMF, has been produced within the project. From the AMF, it is possible to identify the different modelling tasks and consequently also the different computer codes used. A number of different computer codes are used in the assessment of which some are commercial while others are developed for assessment projects. QA requirements must on the one hand take this diversity into account and on the other hand be well defined. In the methodology section of the report the following requirements are defined: - It must be demonstrated that the code is suitable for its purpose. - It must be demonstrated that the code has been properly used. - It must be demonstrated that the code development process has followed appropriate procedures and that the code produces accurate results. Although the requirements are identical for all codes, the measures used to show that the requirements are fulfilled will be different for different codes (for instance due to the fact that for some software the source-code is not available for review). Subsequent to the methodology section, each assessment code is presented and it is shown how the requirements are met

  18. Model summary report for the safety assessment SFR 1 SAR-08

    International Nuclear Information System (INIS)

    2008-03-01

    This document is the model summary report for the safety assessment SFR 1 SAR-08. In the report, the quality assurance measures conducted for the assessment codes are presented together with the chosen methodology. In the safety assessment SFR1 SAR-08, a number of different computer codes are used. In order to better understand how these codes are related an Assessment Model Flowchart, AMF, has been produced within the project. From the AMF, it is possible to identify the different modelling tasks and consequently also the different computer codes used. A number of different computer codes are used in the assessment of which some are commercial while others are developed for assessment projects. QA requirements must on the one hand take this diversity into account and on the other hand be well defined. In the methodology section of the report the following requirements are defined: - It must be demonstrated that the code is suitable for its purpose. - It must be demonstrated that the code has been properly used. - It must be demonstrated that the code development process has followed appropriate procedures and that the code produces accurate results. Although the requirements are identical for all codes, the measures used to show that the requirements are fulfilled will be different for different codes (for instance due to the fact that for some software the source-code is not available for review). Subsequent to the methodology section, each assessment code is presented and it is shown how the requirements are met

  19. Safety assessment for the 24 CANFLEX-NU bundle demonstration irradiation at Wolsong-1 generation

    Energy Technology Data Exchange (ETDEWEB)

    Suk, Ho Chun; Cho, M. S.; Jun, J. S. and others

    2001-06-01

    This document is a report on the safety assessment for the 24 CANFLEX-NU(CANDU Flexible fuelling - Natural Uranium) fuel bundle demonstration irradiation at Wolsong-1 Generating Station. The CANFLEX fuel bundle as a CANDU advanced fuel has been jointly developed by KAERI/AECL. This document describes the rationale for the demonstration irradiation and comments on the Korean government licensing issues such as the status of the CANFLEX fuel irradiations at NRU research reactor in AECL, status and plan of the CANFLEX fuel irradiations at a CANDU-6 power reactor, status of the water CHF(Critical Heat Flux) test at Stern Laboratories and the CHF correlation. This documents presents an assessment the consequences of postulated accidents with all safety system available during demonstration irradiation of 24 CANFLEX-NU fuel bundles at Wolsong-1 Generating Station. The assessment is made by two kinds of approaches. One approach is based on the document of the safety assessment for the 24 CANFLEX-NU fuel bundle demonstration irradiation at Point Lepreau Generating Station. The other approach is taken from the safety analyses using the analysis methods and assumptions used in the final safety reports on the 600 MWe CANDU-PHWR Wolsung-2, 3, and 4 Nuclear Power Plants for the Korea Electric Power Cooperation. The analyses are not comprehensive reviews of the postulated accidents, but examination of the expected difference in accident consequences because of the presence of 24 CANFLEX fuel bundles in two channels. The approach is to compare the difference to the safety margin for 37-element bundle cases.

  20. 24 CFR 902.1 - Purpose and general description.

    Science.gov (United States)

    2010-04-01

    ... assessments. The Real Estate Assessment Center (REAC) is responsible for assessing and scoring the performance... uniform and objective protocols for the physical inspection of properties and the financial assessment of... URBAN DEVELOPMENT PUBLIC HOUSING ASSESSMENT SYSTEM General Provisions § 902.1 Purpose and general...

  1. IEA-R1 renewed primary coolant piping system stress analysis

    International Nuclear Information System (INIS)

    Fainer, Gerson; Faloppa, Altair A.; Oliveira, Carlos A. de; Mattar Neto, Miguel

    2015-01-01

    A partial replacement of the IEA-R1 piping system was conducted in 2014. The aim of this work is to perform the stress analysis of the renewed primary piping system of the IEA-R1, taking into account the as built conditions and the pipe modifications. The nuclear research reactor IEA-R1 is a pool type reactor designed by Babcox-Willcox, which is operated by IPEN since 1957. The primary coolant system is responsible for removing the residual heat of the Reactor core. As a part of the life management, a regular inspection detected some degradation in the primary piping system. In consequence, part of the piping system was replaced. The partial renewing of the primary piping system did not imply in major piping layout modifications. However, the stress condition of the piping systems had to be reanalyzed. The structural stress analysis of the primary piping systems is now presented and the final results are discussed. (author)

  2. Systemic corticosteroids and early administration of antiviral agents for pneumonia with acute wheezing due to influenza A(H1N1pdm09 in Japan.

    Directory of Open Access Journals (Sweden)

    Koichiro Kudo

    Full Text Available BACKGROUND: Pneumonia patients with wheezing due to influenza A(H1N1pdm09 were frequently treated with systemic corticosteroids in Japan although systemic corticosteroid for critically ill patients with pneumonia caused by influenza A(H1N1pdm09 has been controversial. Applicability of systemic corticosteroid treatment needs to be evaluated. METHODS/PRINCIPAL FINDINGS: We retrospectively reviewed 89 subjects who were diagnosed with influenza A(H1N1pdm09 and admitted to a national hospital, Tokyo during the pandemic period. The median age of subjects (45 males was 8 years (range, 0-71. All subjects were treated with antiviral agents and the median time from symptom onset to initiation of antiviral agents was 2 days (range, 0-7. Subjects were classified into four groups: upper respiratory tract infection, wheezing illness, pneumonia with wheezing, and pneumonia without wheezing. The characteristics of each group was evaluated. A history of asthma was found more frequently in the wheezing illness (55.6% and pneumonia with wheezing (43.3% groups than in the other two groups (p = 0.017. Corticosteroid treatment was assessed among subjects with pneumonia. Oxygen saturation was lower in subjects receiving corticosteroids (steroid group than in subjects not receiving corticosteroids (no-steroid group (p<0.001. The steroid group required greater oxygen supply than the no-steroid group (p<0.001. No significant difference was found by the Kaplan-Meier method between the steroid and the no-steroid groups in hours to fever alleviation from the initiation of antiviral agents and hospitalization days. In logistic regression analysis, wheezing, pneumonia and oxygen saturation were independent factors associated with using systemic corticosteroids. CONCLUSION: Patients with wheezing and a history of asthma were frequently found in the study subjects. Systemic corticosteroids together with early administration of antiviral agents to pneumonia with wheezing and

  3. Waiting time distribution in M/D/1 queueing systems

    DEFF Research Database (Denmark)

    Iversen, Villy Bæk; Staalhagen, Lars

    1999-01-01

    The well-known formula for the waiting time distribution of M/D/1 queueing systems is numerically unsuitable when the load is close to 1.0 and/or the results for a large waiting time are required. An algorithm for any load and waiting time is presented, based on the state probabilities of M/D/1...

  4. 41 CFR 101-39.104-1 - Consolidations into a fleet management system.

    Science.gov (United States)

    2010-07-01

    ... fleet management system. 101-39.104-1 Section 101-39.104-1 Public Contracts and Property Management..., TRANSPORTATION, AND MOTOR VEHICLES 39-INTERAGENCY FLEET MANAGEMENT SYSTEMS 39.1-Establishment, Modification, and Discontinuance of Interagency Fleet Management Systems § 101-39.104-1 Consolidations into a fleet management...

  5. Dimensionality effects on magnetic properties of FexCo1-x nanoclusters on Pt(1 1 1)

    Science.gov (United States)

    Miranda, I. P.; Igarashi, R. N.; Klautau, A. B.; Petrilli, H. M.

    2017-11-01

    The behavior of local magnetic moments and exchange coupling parameters of FexCo1-x nanostructures (nanowires and compact clusters) on the fcc Pt(1 1 1) surface is here investigated using the first-principles real-space RS-LMTO-ASA method, in the framework of the DFT. Different configurations of FexCo1-x trimers and heptamers on Pt(1 1 1) are considered, varying the positions and the concentration of Fe or Co atoms. We discuss the influence of dimensionality and stoichiometry changes on the magnetic properties, specially on the orbital moments, which are very important in establishing a nanoscopic understanding of delocalized electron systems. We demonstrate the existence of a strictly decreasing nonlinear trend of the average orbital moments with the Fe concentration for the compact clusters, different from what was found for FexCo1-x nanowires on Pt(1 1 1) and also for corresponding higher-dimensional systems (FexCo1-x monolayer on Pt(1 1 1) and FexCo1-x bulk). The average spin moments, however, are invariably described by a linear function with respect to stoichiometry. In all studied cases, the nearest neighbors exchange couplings have shown to be strongly ferromagnetic.

  6. Low toxicity binder systems for tape cast Ce0.9Gd0.1O1.95 laminates

    DEFF Research Database (Denmark)

    Klemensø, Trine; Menon, Mohan; Ramousse, Severine

    2010-01-01

    Conventional binder systems for tape casting contain toxic phthalate plasticizers and butanone (MEK) as part of the solvent. The effects of exchanging the phthalate with a non-toxic alternative, and butanone with ethanol, were studied on laminates of high-green density CGO (Ce0.9Gd0.1O1.95) tapes....... Samples were prepared with a binder system containing DBP (dibutyl phthalate) plasticizer and MEK solvent, and with a binder system based on a non-toxic non-phthalate plasticizer and ethanol. In both systems, the weight ratio of plasticizer to the PVB (polyvinyl butyral) binder was varied between 0.......4 and 0.7. Substitution to the less toxic binder system had no adverse impacts on the microstructure. In fact, denser packing and improved homogeneity were observed with the non-phthalate-based system at ratio 0.5 indicating improved dispersion in this system. The denser packing also coincided...

  7. Assessment of grassland ecosystem conditions in the Southwestern United States. Vol. 1

    Science.gov (United States)

    Deborah M. Finch

    2004-01-01

    This report is volume 1 of a two-volume ecological assessment of grassland ecosystems in the Southwestern United States. Broadscale assessments are syntheses of current scientific knowledge, including a description of uncertainties and assumptions, to provide a characterization and comprehensive description of ecological, social, and economic components within an...

  8. 41 CFR 109-1.5205 - Personal property management system changes.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Personal property management system changes. 109-1.5205 Section 109-1.5205 Public Contracts and Property Management Federal... Personal property management system changes. Any proposed significant change to a designated contractor's...

  9. Postclosure performance assessment of the SCP [Site Characterization Plan] conceptual design for horizontal emplacement: Revision 1

    International Nuclear Information System (INIS)

    1987-08-01

    This report is a preliminary postclosure performance assessment of the repository design specified in the Site Characterization Plan Conceptual Design Report (SCP-CDR) for horizontal emplacement of high-level nuclear waste. At the time that these analyses were done, horizontal emplacement was the preferred orientation for the waste packages but vertical emplacement is now the reference design. This assessment consists of (1) a review of the regulatory requirements and strategy to demonstrate compliance with these requirements, (2) an analysis of the performance of the total repository system, (3) an analysis of the thermomechanical behavior of the repository, (4) an analysis of brine mobility in the repository, (5) an analysis of the waste package performance, (6) an analysis of the performance of seals, and (7) comments on the sensitivity of the various performance measures to uncertainties in the data and models. These are preliminary analyses and, in most cases, involve bounding calculations of the repository behavior. They have several purposes including (1) assessing how well this conceptual design ''measures up'' against requirements, (2) gaining experience in implementing the performance assessment strategy and tools and thereby learning where improvements are needed, (3) helping to identify needed data, and (4) helping to indicate required design modifications. 26 refs., 40 figs., 20 tabs

  10. Southern Appalachian assessment. Summary report, Report 1 of 5

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This final report for the Southern Appalachian Man and the Biosphere Program is comprised of two documents: (1) a brief summary of programs and projects, and (2) a more extensive summary report included as an attachment. The purpose of the program is to promote a sustainable balance between the conservation of biological diversity, compatible economic uses, and cultural values across the Southern Appalachians. Program and project areas addressing regional issues include environmental monitoring and assessment, sustainable development/sustainable technologies, conservation biology, ecosystem management, environmental education and training, cultural and historical resources, and public information and education. The attached summary report is one of five that documents the results of the Southern Appalachian Assessment; it includes atmospheric, social/cultural/economic, terrestrial, and aquatic reports.

  11. Design and construction of OGL-1 Specimen Transfer System

    International Nuclear Information System (INIS)

    Nakamura, Kunio; Saruta, Tohru; Nabeya, Hideaki; Nakagaki, Shogo; Nishizaki, Tadashi.

    1977-11-01

    OGL-1 is the first high temperature gas in-pile loop in Japan, which is installed in JMTR of Oarai Research Establishment, JAERI. As the JMTR is the PWR type, specimens must be set in the loop with a remote control system ''OGL-1 Specimen Transfer System'' because of the needs for moisture prevention and radiation shielding. Described in this report are design philosophy, loop development, problems in construction, inspection and operation. (auth.)

  12. Study on the ternary mixed ligand complex of palladium(II)-aminophylline-fluorescein sodium by resonance Rayleigh scattering, second-order scattering and frequency doubling scattering spectrum and its analytical application.

    Science.gov (United States)

    Chen, Peili; Liu, Shaopu; Liu, Zhongfang; Hu, Xiaoli

    2011-01-01

    The interaction between palladium(II)-aminophylline and fluorescein sodium was investigated by resonance Rayleigh scattering, second-order scattering and frequency doubling scattering spectrum. In pH 4.4 Britton-Robinson (BR) buffer medium, aminophylline (Ami) reacted with palladium(II) to form chelate cation([Pd(Ami)]2+), which further reacted with fluorescein sodium (FS) to form ternary mixed ligand complex [Pd(Ami)(FS)2]. As a result, resonance Rayleigh scattering (RRS), second-order scattering (SOS) and frequency doubling scattering spectrum (FDS) were enhanced. The maximum scattering wavelengths of [Pd(Ami)(FS)2] were located at 300 nm (RRS), 650 nm (SOS) and 304 nm (FDS). The scattering intensities were proportional to the Ami concentration in a certain range and the detection limits were 7.3 ng mL(-1) (RRS), 32.9 ng mL(-1) (SOS) and 79.1 ng mL(-1) (FDS), respectively. Based on it, the new simple, rapid, and sensitive scattering methods have been proposed to determine Ami in urine and serum samples. Moreover, the formation mechanism of [Pd(Ami)(FS)2] and the reasons for enhancement of RRS were fully discussed. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  13. Effect of the systemic inflammatory response, as provoked by elective orthopaedic surgery, on HbA1c.

    Science.gov (United States)

    Chadburn, Andrew J; Garman, Elizabeth; Abbas, Raad; Modupe, Anu; Ford, Clare; Thomas, Osmond L; Chugh, Sanjiv; Deshpande, Shreeram; Gama, Rousseau

    2017-07-01

    Background In acutely ill patients with new onset hyperglycaemia, plasma glucose cannot reliably distinguish between stress hyperglycaemia and undiagnosed diabetes mellitus. We, therefore, investigated the diagnostic reliability of glycated haemoglobin (HbA1c) in acute illness by prospectively evaluating the effect of the systemic inflammatory response, as provoked by elective orthopaedic surgery, on HbA 1c . Methods HbA 1c and serum C-reactive protein concentrations were compared before and two days after elective knee or hip surgery in 30 patients without diabetes. C-reactive protein was used to assess the systemic inflammatory response. Results The mean (standard deviation) serum C-reactive protein increased following surgery (4.8 [7.5] vs. 179.7 [61.9] mg/L; P<0.0001). HbA 1c was similar before and after surgery (39.2 [5.4] vs. 38.1 [5.1] mmol/moL, respectively; P = 0.4363). Conclusions HbA 1c is unaffected within two days of a systemic inflammatory response as provoked by elective orthopaedic surgery. This suggests that HbA 1c may be able to differentiate newly presenting type 2 diabetes mellitus from stress hyperglycaemia in acutely ill patients with new onset hyperglycaemia.

  14. Simulation of LOFT anticipated-transient experiments L6-1, L6-2, and L6-3 using TRAC-PF1/MOD1

    International Nuclear Information System (INIS)

    Sahota, M.S.

    1984-01-01

    Anticipated-transient experiments L6-1, L6-2, and L6-3, performed at the Loss-of-fluid Test (LOFT) facility, are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1/MOD1). The results are used to assess TRAC-PF1/MOD1 trip and control capabilities, and predictions of thermal-hydraulic phenomena during slow transients. Test L6-1 simulated a loss-of-stream load in a large pressurized-water reactor (PWR), and was initiated by closing the main steam-flow control valve (MSFCV) at its maximum rate, which reduced the heat removal from the secondary-coolant system and increased the primary-coolant system pressure that initiated a reactor scram. Test L6-2 simulated a loss-of-primary coolant flow in a large PWR, and was initiated by tripping the power to the primary-coolant pumps (PCPs) allowing the pumps to coast down. The reduced primary-coolant flow caused a reactor scram. Test L6-3 simulated an excessive-load increase incident in a large PWR, and was initiated by opening the MSFCV at its maximum rate, which increased the heat removal from the secondary-coolant system and decreased the primary-coolant system pressure that initiated a reactor scram. The TRAC calculations accurately predict most test events. The test data and the calculated results for most parameters of interest also agree well

  15. Psychometric Evaluation of the Brachial Assessment Tool Part 1: Reproducibility.

    Science.gov (United States)

    Hill, Bridget; Williams, Gavin; Olver, John; Ferris, Scott; Bialocerkowski, Andrea

    2018-04-01

    To evaluate reproducibility (reliability and agreement) of the Brachial Assessment Tool (BrAT), a new patient-reported outcome measure for adults with traumatic brachial plexus injury (BPI). Prospective repeated-measure design. Outpatient clinics. Adults with confirmed traumatic BPI (N=43; age range, 19-82y). People with BPI completed the 31-item 4-response BrAT twice, 2 weeks apart. Results for the 3 subscales and summed score were compared at time 1 and time 2 to determine reliability, including systematic differences using paired t tests, test retest using intraclass correlation coefficient model 1,1 (ICC 1,1 ), and internal consistency using Cronbach α. Agreement parameters included standard error of measurement, minimal detectable change, and limits of agreement. BrAT. Test-retest reliability was excellent (ICC 1,1 =.90-.97). Internal consistency was high (Cronbach α=.90-.98). Measurement error was relatively low (standard error of measurement range, 3.1-8.8). A change of >4 for subscale 1, >6 for subscale 2, >4 for subscale 3, and >10 for the summed score is indicative of change over and above measurement error. Limits of agreement ranged from ±4.4 (subscale 3) to 11.61 (summed score). These findings support the use of the BrAT as a reproducible patient-reported outcome measure for adults with traumatic BPI with evidence of appropriate reliability and agreement for both individual and group comparisons. Further psychometric testing is required to establish the construct validity and responsiveness of the BrAT. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Risk assessment, session 1-4. International conference 1992. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-07-01

    The international conference on Risk Assessment, 5-9 October 1992, London was organised by the Health and Safety Commission of the UK and co-sponsored by a number of regional and international organizations namely: the European Commission, the ILO, the OECD and WHO. The main sessions of the conference cover what risk assessment means, the role of risk assessment in devising policies and regulations; and risk assessment in practice.

  17. Risk assessment, session 1-4. International conference 1992. Part 1

    International Nuclear Information System (INIS)

    1992-01-01

    The international conference on Risk Assessment, 5-9 October 1992, London was organised by the Health and Safety Commission of the UK and co-sponsored by a number of regional and international organizations namely: the European Commission, the ILO, the OECD and WHO. The main sessions of the conference cover what risk assessment means, the role of risk assessment in devising policies and regulations; and risk assessment in practice

  18. High mobility group box1 (HMGB1) in relation to cutaneous inflammation in systemic lupus erythematosus (SLE)

    NARCIS (Netherlands)

    Abdulahad, D.A.; Westra, J.; Reefman, E.; Zuidersma, E.; Bijzet, J.; Limburg, P.C.; Kallenberg, C.G.M.; Bijl, M.

    2013-01-01

    Photosensitivity is characteristic of systemic lupus erythematosus (SLE). Upon ultraviolet B (UVB) exposure, patients develop inflammatory skin lesions in the vicinity of sunburn cells (SBCs). High mobility group box 1 (HMGB1) is released from apoptotic and activated cells and exerts inflammatory

  19. E-VPMS 1.0: Enhanced Vehicle Parking Monitoring System

    Directory of Open Access Journals (Sweden)

    Shian Lim Yeu

    2018-01-01

    Full Text Available Due to lack of vehicle parking slot in front of Block Q, Faculty of Electrical and Electronic Engineering (FKEE, UTHM, the enhanced vehicle parking monitoring system (E-VPMS 1.0 is developed to identify parking slots available in the parking area as well as to detect double parking problem. Once this system is implemented, time consume for searching available parking slots as well as double parking problem that may cause unwanted accident can be reduced. In the development of E-VPMS 1.0 system, whole system are designed and developed in three different phases; which are video processing phase, login and registration phase, and webview development phase. In video processing phase, video sources are processed through few video processing function. In login and registration phase, series of webpage function have been created that accessible in both smartphone and laptop. While, in webview development phase, webview function have been developed and through this function, content of E-VPMS 1.0 system can be displayed directly via web browser for both smartphone and laptop. Through E-VPMS 1.0, availability parking slots can be checked by registered user through input recorded video before entering the specific parking area. Other than that, performance analysis in terms of numbers of registered user and parking slot availability at different situations such as during peak event or normal event can be managed and controlled by admin through visualisation data method.

  20. 1/f noise: diffusive systems and music

    Energy Technology Data Exchange (ETDEWEB)

    Voss, R.F.

    1975-11-01

    Measurements of the 1/f voltage noise in continuous metal films are reported. At room temperature, samples of pure metals and bismuth (with a carrier density smaller by 10/sup 5/) of similar volume had comparable noise. The results suggest that the noise arises from equilibrium temperature fluctuations modulating the resistance. Spatial correlation of the noise implied that the fluctuations obey a diffusion equation. The empirical inclusion of an explicit 1/f region and appropriate normalization lead to excellent agreement with the measured noise. If the fluctuations are assumed to be spatially correlated, the diffusion equation can yield an extended 1/f region in the power spectrum. The temperature response of a sample to delta and step function power inputs is shown to have the same shape as the autocorrelation function for uncorrelated and correlated temperature fluctuations, respectively. The spectrum obtained from the cosine transform of the measured step function response is in excellent agreement with the measured 1/f voltage noise spectrum. Spatially correlated equilibrium temperature fluctuations are not the dominant source of 1/f noise in semiconductors and metal films. However, the agreement between the low-frequency spectrum of fluctuations in the mean-square Johnson noise voltage and the resistance fluctuation spectrum measured in the presence of a current demonstrates that in these systems the 1/f noise is also due to equilibrium resistance fluctuations. Loudness fluctuations in music and speech and pitch fluctuations in music also show the 1/f behavior. 1/f noise sources, consequently, are demonstrated to be the natural choice for stochastic composition. 26 figures, 1 table. (auth)

  1. Probabilistic safety assessment of French 900 and 1,300 MWe nuclear plants

    International Nuclear Information System (INIS)

    Brisbois, J.; Lanore, J.M.

    1991-08-01

    Although reactor design is mainly governed by deterministic principles in France, the probabilistic approach has been considered an important aid to safety analysis since the early seventies. Various partial probabilistic studies have been performed by Electricite de France, by IPSN and by Framatome, for various types of reactor. In particular, these studies have made it possible to assess the reliability and availability of nuclear power plants safety systems as well as the probability of accident scenarios and have helped to define technical specifications (especially, allowed operating times in the event of a partial unavailability of safety systems). Simultaneously, evaluation methods and corresponding software have been widely developed. Besides. EDF has implemented the Systeme de Recueil de Donnees de Fiabilite - SRDF (Reliability Data Collection System) which allows follow-up of equipment behaviour on all the operating units, and has led to a particularly representative data base. In 1982 the decision was taken at IPSN to carry out a complete PSA for a standard reactor of the 900 MWe type, and in 1986 EDF launched an equivalent study on a 1,300 MWe reactor, taking Unit 3 Paluel as reference. These PSAs were terminated in the course of the first quarter of 1990

  2. Probabilistic safety assessment of French 900 and 1,300 MWe nuclear plants

    International Nuclear Information System (INIS)

    Brisbois, J.; Lanore, J.M.

    1991-01-01

    Although reactor design is mainly governed by deterministic principles in France, the probabilistic approach has been considered an important aid to safety analysis since the early seventies. Various partial probabilistic studies have been performed by Electricite de France, by IPSN and by Framatome, for various types of reactor. In particular, these studies have made it possible to assess the reliability and availability of nuclear power plants safety systems as well as the probability of accident scenarios and have helped to define technical specifications (especially, allowed operating times in the event of a partial unavailability of safety systems). Simultaneously, evaluation methods and corresponding software have been widely developed. Besides. EDF has implemented the Systeme de Recueil de Donnees de Fiabilite - SRDF (Reliability Data Collection System) which allows follow-up of equipment behaviour on all the operating units, and has led to a particularly representative data base. In 1982 the decision was taken at IPSN to carry out a complete PSA for a standard reactor of the 900 MWe type, and in 1986 EDF launched an equivalent study on a 1,300 MWe reactor, taking Unit 3 Paluel as reference. These PSAs were terminated in the course of the first quarter of 1990. (author)

  3. Screening assessment and requirements for a comprehensive assessment: Volume 1, Draft. Columbia River comprehensive impact assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-04-01

    To evaluate the impact to the Columbia River from the Hanford Site-derived contaminants, the U.S. Department of Energy, U.S. Environmental Protection Agency, and Washington State Department of Ecology initiated a study referred to as the Columbia River Comprehensive Impact Assessment (CRCIA). To address concerns about the scope and direction of CRCIA as well as enhance regulator, tribal, stockholder, and public involvement, the CRCIA Management Team was formed in August 1995. The Team agreed to conduct CRCIA using a phased approach. The initial phase, includes two components: 1) a screening assessment to evaluate the potential impact to the river, resulting from current levels of Hanford-derived contaminants in order to support decisions on Interim Remedial Measures, and 2) a definition of the essential work remaining to provide an acceptable comprehensive river impact assessment. The screening assessment is described in Part I of this report. The essential work remaining is Part II of this report. The objective of the screening assessment is to identify areas where the greatest potential exists for adverse effects on humans or the environment. Part I of this report discusses the scope, technical approach, and results of the screening assessment. Part II defines a new paradigm for predecisional participation by those affected by Hanford cleanup decisions.

  4. Screening assessment and requirements for a comprehensive assessment: Volume 1, Draft. Columbia River comprehensive impact assessment

    International Nuclear Information System (INIS)

    1997-04-01

    To evaluate the impact to the Columbia River from the Hanford Site-derived contaminants, the U.S. Department of Energy, U.S. Environmental Protection Agency, and Washington State Department of Ecology initiated a study referred to as the Columbia River Comprehensive Impact Assessment (CRCIA). To address concerns about the scope and direction of CRCIA as well as enhance regulator, tribal, stockholder, and public involvement, the CRCIA Management Team was formed in August 1995. The Team agreed to conduct CRCIA using a phased approach. The initial phase, includes two components: 1) a screening assessment to evaluate the potential impact to the river, resulting from current levels of Hanford-derived contaminants in order to support decisions on Interim Remedial Measures, and 2) a definition of the essential work remaining to provide an acceptable comprehensive river impact assessment. The screening assessment is described in Part I of this report. The essential work remaining is Part II of this report. The objective of the screening assessment is to identify areas where the greatest potential exists for adverse effects on humans or the environment. Part I of this report discusses the scope, technical approach, and results of the screening assessment. Part II defines a new paradigm for predecisional participation by those affected by Hanford cleanup decisions

  5. Phase 1/2a study of the malaria vaccine candidate apical membrane antigen-1 (AMA-1 administered in adjuvant system AS01B or AS02A.

    Directory of Open Access Journals (Sweden)

    Michele D Spring

    Full Text Available This Phase 1/2a study evaluated the safety, immunogenicity, and efficacy of an experimental malaria vaccine comprised of the recombinant Plasmodium falciparum protein apical membrane antigen-1 (AMA-1 representing the 3D7 allele formulated with either the AS01B or AS02A Adjuvant Systems.After a preliminary safety evaluation of low dose AMA-1/AS01B (10 microg/0.5 mL in 5 adults, 30 malaria-naïve adults were randomly allocated to receive full dose (50 microg/0.5 mL of AMA-1/AS01B (n = 15 or AMA-1/AS02A (n = 15, followed by a malaria challenge. All vaccinations were administered intramuscularly on a 0-, 1-, 2-month schedule. All volunteers experienced transient injection site erythema, swelling and pain. Two weeks post-third vaccination, anti-AMA-1 Geometric Mean Antibody Concentrations (GMCs with 95% Confidence Intervals (CIs were high: low dose AMA-1/AS01B 196 microg/mL (103-371 microg/mL, full dose AMA-1/AS01B 279 microg/mL (210-369 microg/mL and full dose AMA-1/AS02A 216 microg/mL (169-276 microg/mL with no significant difference among the 3 groups. The three vaccine formulations elicited equivalent functional antibody responses, as measured by growth inhibition assay (GIA, against homologous but not against heterologous (FVO parasites as well as demonstrable interferon-gamma (IFN-gamma responses. To assess efficacy, volunteers were challenged with P. falciparum-infected mosquitoes, and all became parasitemic, with no significant difference in the prepatent period by either light microscopy or quantitative polymerase chain reaction (qPCR. However, a small but significant reduction of parasitemia in the AMA-1/AS02A group was seen with a statistical model employing qPCR measurements.All three vaccine formulations were found to be safe and highly immunogenic. These immune responses did not translate into significant vaccine efficacy in malaria-naïve adults employing a primary sporozoite challenge model, but encouragingly, estimation of parasite

  6. Double-shell tank waste system assessment status and schedule

    International Nuclear Information System (INIS)

    Walter, E.J.

    1995-01-01

    The integrated program for completing the integrity assessments of the dangerous waste tank systems managed by the Tank Waste Remediation System (TWRS) Division of Westinghouse Hanford Company is presented in the Tank Waste Remediation System Tank System Integrity Assessments Program Plan, WHC-SD-AP017, Rev. 1. The program plan identified the assessment requirements and the general scope to which these requirements applied. Some of these assessment requirements have been met and others are either in process of completion or scheduled to be worked. To define the boundary of the double-shell tank (DST) system and the boundaries of the DST system components (or system parts) for the purpose of performing integrity assessment activities; To identify the planned activities to meet the assessment requirements for each component; Provide the status of the assessment activities; and Project a five year assessment activity schedule

  7. 14 CFR Section 1 - Introduction to System of Accounts and Reports

    Science.gov (United States)

    2010-01-01

    ... AIR CARRIERS General Accounting Provisions Section 1 Introduction to System of Accounts and Reports ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Introduction to System of Accounts and Reports Section 1 Section 1 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION...

  8. Effect of nature convection on heat transfer in the liquid LiPb blanket for FDS-II

    Energy Technology Data Exchange (ETDEWEB)

    Wang Hongyan; Chen Hongli [Huaibei Coal Industry Teachers Coll. (China). Dept. of Physics; Zhou Tao [Chinese Academy of Sciences, Hefei (China). Inst. of Plasma Physics

    2007-07-01

    The He-cooled liquid LiPb tritium breeder (SLL) blanket concept is one of options of the blanket design of the fusion power reactor (FDS-II). The SLL blanket could be developed relatively easily with lower LiPb outlet temperature and slower LiPb flow velocity that allows the utilization of relatively mature material technology. The velocity of the liquid LiPb in the blanket is very slowly only in order to extract tritium. The magnetohydrodynamic (MHD) flow and heat transfer become very complex resulting from the differential heating of walls of the channels, especially adjacent to the First Wall (FW), and internal heat sources inside of the liquid LiPb. It is necessary to analyse the effect of the buoyancy-driven LiPb MHD flow on heat transfer in the channels with electrically and thermally conducting walls adjacent to the FW. The nature convection of the liquid LiPb, due to thermal diffusion, in the poloidal channel adjacent to the FW in the presence of the strong magnetic field of the SLL blanket has been considered and studied. The specially numerical MHD code based on the computational fluid dynamic software has been developed for analysis of the buoyancy-driven MHD flow. The properties of buoyantly convective flows have been investigated for various thermal boundary conditions. The numerical analysis was performed for the effect of nature convection on heat transfer of the liquid LiPb MHD flow in the poloidal channel in the SLL blanket. For the strong temperature gradient in the blanket and internal heat flux of Liquid LiPb, the three-dimensional temperature distributions of the LiPb, the FW and other walls have been given. Finally, The effect of the ratio of MHD buoyancy on the heat transfer characteristics of the LiPb flow have been calculated and presented. (orig.)

  9. 26 CFR 801.1 - Balanced performance measurement system; in general.

    Science.gov (United States)

    2010-04-01

    ... general. 801.1 Section 801.1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... WITHIN THE INTERNAL REVENUE SERVICE § 801.1 Balanced performance measurement system; in general. (a) In general. (1) The regulations in this part 801 implement the provisions of sections 1201 and 1204 of the...

  10. Resident training in a teaching hospital: How do attendings teach in the real operative environment?

    Science.gov (United States)

    Glarner, Carly E; Law, Katherine E; Zelenski, Amy B; McDonald, Robert J; Greenberg, Jacob A; Foley, Eugene F; Wiegmann, Douglas A; Greenberg, Caprice C

    2017-07-01

    The study aim was to explore the nature of intraoperative education and its interaction with the environment where surgical education occurs. Video and audio recording captured teaching interactions between colorectal surgeons and general surgery residents during laparoscopic segmental colectomies. Cases and collected data were analyzed for teaching behaviors and workflow disruptions. Flow disruptions (FDs) are considered deviations from natural case progression. Across 10 cases (20.4 operative hours), attendings spent 11.2 hours (54.7%) teaching, using directing (M = 250.1), and confirming (M = 236.1) most. FDs occurred 410 times, accounting for 4.4 hours of case time (21.57%). Teaching occurred with FD events for 2.4 hours (22.2%), whereas 77.8% of teaching happened outside FD occurrence. Teaching methods shifted from active to passive during FD events to compensate for patient safety. Understanding how FDs impact operative learning will inform faculty development in managing interruptions and improve its integration into resident education. Copyright © 2016. Published by Elsevier Inc.

  11. Evaluation of (vapor + liquid) equilibria for the binary systems (1-octanol + cyclohexane) and (1-octanol + n-hexane), at low alcohol compositions

    International Nuclear Information System (INIS)

    Ovejero, Gabriel; Dolores Romero, M.; Diez, Eduardo; Lopes, Tania; Diaz, Ismael

    2008-01-01

    Isobaric (vapor + liquid) equilibrium at p = 101.32 kPa of pressure has been determined for the systems (1-octanol + cyclohexane) and (1-octanol + n-hexane), at low alcohol mole fractions. These data were satisfactorily correlated, using ASPEN PLUS commercial software, with Wilson, NRTL, and UNIQUAC activity coefficient models to obtain the binary interaction parameters of both mixtures. Also, UNIFAC group contribution method was employed to predict the equilibrium of both mixtures. With regression values an accurate knowledge of (vapor + liquid) equilibrium for both mixtures can be reached in a range of 1-octanol mole fractions less than 0.1. UNIFAC method provides acceptable results for (1-octanol + n-hexane) system but not for (1-octanol + cyclohexane) system

  12. Evaluation of (vapor + liquid) equilibria for the binary systems (1-octanol + cyclohexane) and (1-octanol + n-hexane), at low alcohol compositions

    Energy Technology Data Exchange (ETDEWEB)

    Ovejero, Gabriel [Grupo de Catalisis y Procesos de Separacion (CyPS), Departamento de Ingenieria Quimica, Facultad de C. Quimicas, Universidsad Complutense de Madrid, Avda. Complutense s/n, 28040 Madrid (Spain)], E-mail: govejero@quim.ucm.es; Dolores Romero, M.; Diez, Eduardo; Lopes, Tania; Diaz, Ismael [Grupo de Catalisis y Procesos de Separacion (CyPS), Departamento de Ingenieria Quimica, Facultad de C. Quimicas, Universidsad Complutense de Madrid, Avda. Complutense s/n, 28040 Madrid (Spain)

    2008-11-15

    Isobaric (vapor + liquid) equilibrium at p = 101.32 kPa of pressure has been determined for the systems (1-octanol + cyclohexane) and (1-octanol + n-hexane), at low alcohol mole fractions. These data were satisfactorily correlated, using ASPEN PLUS commercial software, with Wilson, NRTL, and UNIQUAC activity coefficient models to obtain the binary interaction parameters of both mixtures. Also, UNIFAC group contribution method was employed to predict the equilibrium of both mixtures. With regression values an accurate knowledge of (vapor + liquid) equilibrium for both mixtures can be reached in a range of 1-octanol mole fractions less than 0.1. UNIFAC method provides acceptable results for (1-octanol + n-hexane) system but not for (1-octanol + cyclohexane) system.

  13. Ultraviolet-A1 irradiation therapy for systemic lupus erythematosus.

    Science.gov (United States)

    McGrath, H

    2017-10-01

    Systemic lupus erythematosus (lupus, SLE) is a chronic autoimmune disease characterized by the production of autoantibodies, which bind to antigens and are deposited within tissues to fix complement, resulting in widespread systemic inflammation. The studies presented herein are consistent with hyperpolarized, adenosine triphosphate (ATP)-deficient mitochondria being central to the disease process. These hyperpolarized mitochondria resist the depolarization required for activation-induced apoptosis. The mitochondrial ATP deficits add to this resistance to apoptosis and also reduce the macrophage energy that is needed to clear apoptotic bodies. In both cases, necrosis, the alternative pathway of cell death, results. Intracellular constituents spill into the blood and tissues, eliciting inflammatory responses directed at their removal. What results is "autoimmunity." Ultraviolet (UV)-A1 photons have the capacity to remediate this aberrancy. Exogenous exposure to low-dose, full-body, UV-A1 radiation generates singlet oxygen. Singlet oxygen has two major palliative actions in patients with lupus and the UV-A1 photons themselves have several more. Singlet oxygen depolarizes the hyperpolarized mitochondrion, triggering non-ATP-dependent apoptosis that deters necrosis. Next, singlet oxygen activates the gene encoding heme oxygenase (HO-1), a major governor of systemic homeostasis. HO-1 catalyzes the degradation of the oxidant heme into biliverdin (converted to bilirubin), Fe, and carbon monoxide (CO), the first three of these exerting powerful antioxidant effects, and in conjunction with a fourth, CO, protecting against injury to the coronary arteries, the central nervous system, and the lungs. The UV-A1 photons themselves directly attenuate disease in lupus by reducing B cell activity, preventing the suppression of cell-mediated immunity, slowing an epigenetic progression toward SLE, and ameliorating discoid and subacute cutaneous lupus. Finally, a combination of these

  14. Ultraviolet-A1 irradiation therapy for systemic lupus erythematosus

    Science.gov (United States)

    2017-01-01

    Systemic lupus erythematosus (lupus, SLE) is a chronic autoimmune disease characterized by the production of autoantibodies, which bind to antigens and are deposited within tissues to fix complement, resulting in widespread systemic inflammation. The studies presented herein are consistent with hyperpolarized, adenosine triphosphate (ATP)-deficient mitochondria being central to the disease process. These hyperpolarized mitochondria resist the depolarization required for activation-induced apoptosis. The mitochondrial ATP deficits add to this resistance to apoptosis and also reduce the macrophage energy that is needed to clear apoptotic bodies. In both cases, necrosis, the alternative pathway of cell death, results. Intracellular constituents spill into the blood and tissues, eliciting inflammatory responses directed at their removal. What results is “autoimmunity.” Ultraviolet (UV)-A1 photons have the capacity to remediate this aberrancy. Exogenous exposure to low-dose, full-body, UV-A1 radiation generates singlet oxygen. Singlet oxygen has two major palliative actions in patients with lupus and the UV-A1 photons themselves have several more. Singlet oxygen depolarizes the hyperpolarized mitochondrion, triggering non-ATP-dependent apoptosis that deters necrosis. Next, singlet oxygen activates the gene encoding heme oxygenase (HO-1), a major governor of systemic homeostasis. HO-1 catalyzes the degradation of the oxidant heme into biliverdin (converted to bilirubin), Fe, and carbon monoxide (CO), the first three of these exerting powerful antioxidant effects, and in conjunction with a fourth, CO, protecting against injury to the coronary arteries, the central nervous system, and the lungs. The UV-A1 photons themselves directly attenuate disease in lupus by reducing B cell activity, preventing the suppression of cell-mediated immunity, slowing an epigenetic progression toward SLE, and ameliorating discoid and subacute cutaneous lupus. Finally, a combination of

  15. Imaging MOSS tomographic system for H-1NF

    International Nuclear Information System (INIS)

    Glass, F.; Howard, J.

    1999-01-01

    A tomographic diagnostic utilising the Modulated Optical Solid-State spectrometer (MOSS) is planned for the H-1NF stellarator at the ANU. It is designed to create two-dimensional temperature or velocity maps of a poloidal cross-section of the high temperature plasma of H-1NF. The introduction of the MOSS spectrometers has enabled the development of several diagnostics to be used on the H-1NF stellerator. The MOSS spectrometer allows calculations of the plasma temperature and bulk velocity based on a line-integrated measurement of light emitted from electronic transitions within the plasma. A tomographic system utilising a rotatable multi-view ring apparatus and spatial multiplexing through a MOSS spectrometer is currently being developed. The ring apparatus is placed inside the H-1NF vessel and encircles the plasma. Multiple line-of-sight views collect light through a poloidal cross-section of the plasma and the emitted light is coupled into large core optical fibres. The transmitted light, via the optical fibre bundle, is then imaged through a large aperture MOSS spectrometer and onto another optical fibre array. Each fibre is then fed into a photomultiplier tube for signal detection. Characterisation of the properties of the lithium niobate (LiNbO 3 ) crystal used for modulation in the MOSS spectrometer is being undertaken to account for ray divergence in the imaging system. Tomographic techniques enable the construction of a temperature or velocity map of the poloidal cross-section. Rotating the ring apparatus to a new viewing position for the next pulse of plasma should allow an accurate picture to be built up based on the reproducibility of the plasma pulses. It is expected that initial testing of the system will begin in May when H-1NF begins operations at 0.5 Telsa field strength

  16. Magnetic phase diagram of the Ca1-xMnxO systems

    International Nuclear Information System (INIS)

    Masrour, R.; Hamedoun, M.

    2008-01-01

    The magnetic properties of the Ca 1-x Mn x O systems in the range 0≤x≤1 have been studied by mean field theory and high-temperature series expansions (HTSEs). By using the first theory, we have evaluated the nearest neighbour and the next-neighbour super-exchange interaction J 1 (x) and J 2 (x) respectively, in the range 0.45≤x≤1. The corresponding classical exchange energy for magnetic structure is obtained for the Ca 1-x Mn x O systems. The HTSEs combined with the Pade approximants (PA) method is applied to the Ca 1-x Mn x O systems; we have obtained the magnetic phase diagrams (T N or T SG versus dilution x) in the range 0≤x≤1. The obtained theoretical results are in agreement with experimental ones obtained by magnetic measurements. The critical exponents associated with the magnetic susceptibility (γ) and the correlation lengths (ν) are deduced in the range 0≤x≤1

  17. MELCOR 1.8.2 assessment: The MP-1 and MP-2 late phase melt progression experiments

    International Nuclear Information System (INIS)

    Tautges, T.J.

    1994-05-01

    MELCOR is a fully integrated, engineering-level computer code being developed at Sandia National Laboratories for the USNRC, that models the entire spectrum of severe accident phenomena in a unified framework for both BWRs and PWRs. As a part of an ongoing assessment program, MELCOR has been used to model the MP-1 and MP-2 experiments, which provided data for late-phase melt progression in PWR geometries. Core temperature predicted by MELCOR were within 250--500 K of measured data in both MP-1 and MP-2. Relocation in the debris bed and metallic crust regions of MP-2 was predicted accurately compared to PIE data. Temperature gradients in lower portions of the test bundle were not predicted well in both MP-1 and MP-2, due to the lack of modeling of the heat transfer path to the cooling jacket in those portions of the test bundles. Fifteen sensitivity studies were run on various core (COR), control volume hydrodynamics (CVH) and heat structures (HS) package parameters. No unexpected sensitivities were found, and in particular there were no sensitivities to reduced time step, finer nodalization or to computer platform. Calculations performed by the DEBRIS and TAC2D codes for MP-1 and MP-2 showed better agreement with measured data than those performed by MELCOR. This was expected, through, due to the fully 2-dimensional modeling used in the other codes

  18. Retinopathy is associated with impaired myocardial function assessed by advanced echocardiography in type 1 diabetes patients – The Thousand & 1 Study

    DEFF Research Database (Denmark)

    Nouhravesh, Nina; Andersen, Henrik U; Jensen, Jan S

    2016-01-01

    AIMS: Retinopathy and heart disease in Type 1 Diabetes Mellitus (Type 1 DM) may be associated; however previous results have been conflicting. Tissue Doppler Imaging (TDI) and speckle-tracking echocardiography (STE) quantify myocardial function not assessable by conventional echocardiography. We...... investigated the association between severity of retinopathy and early myocardial dysfunction using conventional echocardiography, TDI and STE in Type 1 DM patients. METHODS: Type 1 Diabetes Mellitus patients without known heart disease were included from the Steno Diabetes Center. The cross sectional...... association between retinopathy and myocardial function was analyzed in uni-and multivariable models. Retinopathy was categorized as nil-, simplex- or proliferative retinopathy. RESULTS: A total of 1090 Type 1 Diabetes Mellitus patients were included, mean age was 49.6years and 53% were males. Left...

  19. Assessment of TRAC-PF1/MOD1 against a loss-of-grid transient in Ringhals 4 power plant

    International Nuclear Information System (INIS)

    Sjoberg, A.; Almberger, J.; Sandervag, O.

    1989-07-01

    A loss of grid transient in a three loop Westinghouse PWR has been simulated with the frozen version of TRAC-PF1/MOD1 computer code. The results reveal the capability of the code to qualitatively predict the different pertinent phenomena and the data comparison was quite encouraging. Accurate predictions of the system response required careful determination of the boundary conditions simulating the turbine governor valves and steam dump valves behaviour. An explicit modeling of the steam generator internals was also found to be important for the results. It was also revealed that the pressurizer system including spray and heaters and their operation should be modeled in some detail for proper response. 4 refs., 18 figs

  20. New Fast Beam Conditions Monitoring (BCM1F) system for CMS

    Science.gov (United States)

    Zagozdzinska, A. A.; Bell, A. J.; Dabrowski, A. E.; Hempel, M.; Henschel, H. M.; Karacheban, O.; Przyborowski, D.; Leonard, J. L.; Penno, M.; Pozniak, K. T.; Miraglia, M.; Lange, W.; Lohmann, W.; Ryjov, V.; Lokhovitskiy, A.; Stickland, D.; Walsh, R.

    2016-01-01

    The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F—one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns bunch structure.

  1. A 2+1 non-isospectral discrete integrable system and its discrete integrable coupling system

    International Nuclear Information System (INIS)

    Yu Fajun; Zhang Hongqing

    2006-01-01

    In this Letter by considering a (2+1)-dimensional discrete non-isospectral linear problem, a new (2+1)-dimensional integrable lattice hierarchy is constructed. It shows that generalization of the Blaszak-Marciniak lattice hierarchy can be obtained as a reduction. Then an extended algebraic system X-bar of X is presented, from which the integrable coupling system of the (2+1)-dimensional discrete non-isospectral Blaszak-Marciniak lattice equations are obtained

  2. Improvement of multi-dimensional realistic thermal-hydraulic system analysis code, MARS 1.3

    International Nuclear Information System (INIS)

    Lee, Won Jae; Chung, Bub Dong; Jeong, Jae Jun; Ha, Kwi Seok

    1998-09-01

    The MARS (Multi-dimensional Analysis of Reactor Safety) code is a multi-dimensional, best-estimate thermal-hydraulic system analysis code. This report describes the new features that have been improved in the MARS 1.3 code since the release of MARS 1.3 in July 1998. The new features include: - implementation of point kinetics model into the 3D module - unification of the heat structure model - extension of the control function to the 3D module variables - improvement of the 3D module input check function. Each of the items has been implemented in the developmental version of the MARS 1.3.1 code and, then, independently verified and assessed. The effectiveness of the new features is well verified and it is shown that these improvements greatly extend the code capability and enhance the user friendliness. Relevant input data changes are also described. In addition to the improvements, this report briefly summarizes the future code developmental activities that are being carried out or planned, such as coupling of MARS 1.3 with the containment code CONTEMPT and the three-dimensional reactor kinetics code MASTER 2.0. (author). 8 refs

  3. Improvement of multi-dimensional realistic thermal-hydraulic system analysis code, MARS 1.3

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jae; Chung, Bub Dong; Jeong, Jae Jun; Ha, Kwi Seok

    1998-09-01

    The MARS (Multi-dimensional Analysis of Reactor Safety) code is a multi-dimensional, best-estimate thermal-hydraulic system analysis code. This report describes the new features that have been improved in the MARS 1.3 code since the release of MARS 1.3 in July 1998. The new features include: - implementation of point kinetics model into the 3D module - unification of the heat structure model - extension of the control function to the 3D module variables - improvement of the 3D module input check function. Each of the items has been implemented in the developmental version of the MARS 1.3.1 code and, then, independently verified and assessed. The effectiveness of the new features is well verified and it is shown that these improvements greatly extend the code capability and enhance the user friendliness. Relevant input data changes are also described. In addition to the improvements, this report briefly summarizes the future code developmental activities that are being carried out or planned, such as coupling of MARS 1.3 with the containment code CONTEMPT and the three-dimensional reactor kinetics code MASTER 2.0. (author). 8 refs.

  4. Studies on dechlorination of DDT (1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane) using magnesium/palladium bimetallic system

    International Nuclear Information System (INIS)

    Gautam, Sumit Kumar; Suresh, Sumathi

    2007-01-01

    The aim of our investigation was to compare the rates of dechlorination of DDT using Mg 0 /Pd 4+ system in two different reaction phases, namely, water-acetone and 0.05% biosurfactant in water. Since palladium is expensive and its toxicity effects are not well known we also examined the reuse efficiency of Pd 0 immobilized on alumina for dechlorinating DDT. Studies on the dechlorination of DDT in water-acetone (1:1, v/v) and 0.05% biosurfactant phases revealed that the reaction followed second order kinetics and rate of reaction is dependent upon both initial concentrations of the target compound and Mg 0 /Pd 4+ . The presence of acid enhanced the rate of reaction by providing protons and preventing passivation of metal that occurs due to deposition of magnesium hydroxide. GC-MS analyses revealed the formation of completely dechlorinated hydrocarbon skeleton of DDT namely, diphenylethane (DPE), as the end product in both reaction phases (water-acetone and 0.05% biosurfactant in water) thereby implying the removal of all five chlorine atoms (three alkyl and two aryl) of DDT. The optimum ratio of water and acetone to facilitate successful dechlorination reaction was found to be 9:1. Results suggested that salt form (K 2 PdCl 6 ) of palladium had higher potential to dechlorinate DDT as compared to pellet (Pd 0 -alumina) form (efficiencies of 95 and 36%, respectively, for 100 ppm initial concentration of DDT). We noted that Pd 0 -alumina pellets could be reused at least four times for successful dechlorination of DDT provided Mg 0 granules are present in sufficient quantity. Technical grade DDT (50 ppm) containing significant amounts of DDD was dechlorinated almost completely by the Mg 0 /Pd 4+ (10 mg/0.2 mg/ml) within 1 h in water-biosurfactant phase. Our studies reveal that Mg/Pd system is a promising option due to its high reactivity and its ability to achieve complete dechlorination of DDT. This bimetallic system may be useful for designing indigenous permeable

  5. An universal multi-parameter data acquisition system MOLDAS1

    International Nuclear Information System (INIS)

    Jiao Dunpang; Zhou Yanyen; Ge Wenxiu; Wang Yanyu; Yu Jusheng; Jing Lan

    1988-01-01

    MOLDAS1 is a data acquisition system to be used for data-taking from reactions induced by heavy-ion in IMP. Its configuration both on hardware and software, system control logic, data flow and functions are intraduced. System specification is discussed as well

  6. Sequence Coding and Search System for licensee event reports: user's guide. Volume 1, Revision 1

    International Nuclear Information System (INIS)

    Greene, N.M.; Mays, G.T.; Johnson, M.P.

    1985-04-01

    Operating experience data from nuclear power plants are essential for safety and reliability analyses, especially analyses of trends and patterns. The licensee event reports (LERs) that are submitted to the Nuclear Regulatory Commission (NRC) by the nuclear power plant utilities contain much of this data. The NRC's Office for Analysis and Evaluation of Operational Data (AEOD) has developed, under contract with NSIC, a system for codifying the events reported in the LERs. The primary objective of the Sequence Coding and Search System (SCSS) is to reduce the descriptive text of the LERs to coded sequences that are both computer-readable and computer-searchable. This system provides a structured format for detailed coding of component, system, and unit effects as well as personnel errors. The database contains all current LERs submitted by nuclear power plant utilities for events occurring since 1981 and is updated on a continual basis. This four volume report documents and describes SCSS in detail. Volume 1 is a User's Guide for searching the SCSS database. This volume contains updated material through February 1985 of the working version of ORNL/NSIC-223, Vol. 1

  7. Co-expression of human cytochrome P4501A1 (CYP1A1) variants and human NADPH-cytochrome P450 reductase in the baculovirus/insect cell system.

    Science.gov (United States)

    Schwarz, D; Kisselev, P; Honeck, H; Cascorbi, I; Schunck, W H; Roots, I

    2001-06-01

    1. Three human cytochrome P4501A1 (CYP1A1) variants, wild-type (CYP1A1.1), CYP1A1.2 (1462V) and CYP1A1.4 (T461N), were co-expressed with human NADPH-P450 reductase (OR) in Spodoptera frugiperda (Sf9) insect cells by baculovirus co-infection to elaborate a suitable system for studying the role of CYPA1 polymorphism in the metabolism of exogenous and endogenous substrates. 2. A wide range of conditions was examined to optimize co-expression with regard to such parameters as relative multiplicity of infection (MOI), time of harvest, haem precursor supplementation and post-translational stabilization. tinder optimized conditions, almost identical expression levels and molar OR/CYP1A1 ratios (20:1) were attained for all CYP1A1 variants. 3. Microsomes isolated from co-infected cells demonstrated ethoxyresorufin deethlylase activities (nmol/min(-1) nmol(-1) CYP1A1) of 16.0 (CYP1A1.1), 20.5 (CYP1A1.2) and 22.5 (CYP1A1.4). Pentoxyresorufin was dealkylated approximately 10-20 times slower with all enzyme variants. 4. All three CYP1A1 variants were active in metabolizing the precarcinogen benzo[a]pyrene (B[a]P), with wild-type enzyme showing the highest activity, followed by CYP1A1.4 (60%) and CYP1A1.2 (40%). Each variant produced all major metabolites including B[a]P-7,8-dihydrodiol, the precursor of the ultimate carcinogenic species. 5. These studies demonstrate that the baculovirus-mediated co-expression-by-co-infection approach all CYP1A1 variants yields functionally active enzyme systems with similar molar OR/CYP1A1 ratios, thus providing suitable preconditions to examine the metabolism of and environmental chemicals by the different CY1A1 variants.

  8. METH-33 - Performance assessment for the high resolution and wide swath (HRWS) post-Sentinel-1 SAR system

    DEFF Research Database (Denmark)

    Zonno, Mariantonietta; Maria J., Sanjuan-Ferrer,; Lopez-Dekker, Paco

    The next generation, post-Sentinel-1, ESA’s C-band synthetic aperture radar (SAR) system is conceived to provide simultaneously high azimuth resolution and wide swath width (HRWS).There are different ways in which the imaging capabilities of the HRWS SAR system can be exploited, which translate...... or numerical models and, if these are not available, real SAR images as well as numerical algorithms and some explicit simulations of the data and of the inversion process are employed. The tool uses as input the HRWS SAR instrument performance for the different applicable modes and produces as output results...

  9. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system

    International Nuclear Information System (INIS)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data

  10. An assessment of H1N1 influenza-associated acute respiratory distress syndrome severity after adjustment for treatment characteristics.

    Directory of Open Access Journals (Sweden)

    Brent P Riscili

    2011-03-01

    Full Text Available Pandemic influenza caused significant increases in healthcare utilization across several continents including the use of high-intensity rescue therapies like extracorporeal membrane oxygenation (ECMO or high-frequency oscillatory ventilation (HFOV. The severity of illness observed with pandemic influenza in 2009 strained healthcare resources. Because lung injury in ARDS can be influenced by daily management and multiple organ failure, we performed a retrospective cohort study to understand the severity of H1N1 associated ARDS after adjustment for treatment. Sixty subjects were identified in our hospital with ARDS from "direct injury" within 24 hours of ICU admission over a three month period. Twenty-three subjects (38.3% were positive for H1N1 within 72 hours of hospitalization. These cases of H1N1-associated ARDS were compared to non-H1N1 associated ARDS patients. Subjects with H1N1-associated ARDS were younger and more likely to have a higher body mass index (BMI, present more rapidly and have worse oxygenation. Severity of illness (SOFA score was directly related to worse oxygenation. Management was similar between the two groups on the day of admission and subsequent five days with respect to tidal volumes used, fluid balance and transfusion practices. There was, however, more frequent use of "rescue" therapy like prone ventilation, HFOV or ECMO in H1N1 patients. First morning set tidal volumes and BMI were significantly associated with increased severity of lung injury (Lung injury score, LIS at presentation and over time while prior prescription of statins was protective. After assessment of the effect of these co-interventions LIS was significantly higher in H1N1 patients. Patients with pandemic influenza-associated ARDS had higher LIS both at presentation and over the course of the first six days of treatment when compared to non-H1N1 associated ARDS controls. The difference in LIS persisted over the duration of observation in patients

  11. Beam Test of the ATLAS Level-1 Calorimeter Trigger System

    CERN Document Server

    Garvey, J; Mahout, G; Moye, T H; Staley, R J; Thomas, J P; Typaldos, D; Watkins, P M; Watson, A; Achenbach, R; Föhlisch, F; Geweniger, C; Hanke, P; Kluge, E E; Mahboubi, K; Meier, K; Meshkov, P; Rühr, F; Schmitt, K; Schultz-Coulon, H C; Ay, C; Bauss, B; Belkin, A; Rieke, S; Schäfer, U; Tapprogge, T; Trefzger, T; Weber, GA; Eisenhandler, E F; Landon, M; Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J; Gee, C N P; Gillman, A R; Mirea, A; Perera, V J O; Qian, W; Sankey, D P C; Bohm, C; Hellman, S; Hidvegi, A; Silverstein, S

    2005-01-01

    The Level-1 Calorimter Trigger consists of a Preprocessor (PP), a Cluster Processor (CP), and a Jet/Energy-sum Processor (JEP). The CP and JEP receive digitised trigger-tower data from the Preprocessor and produce Region-of-Interest (RoIs) and trigger multiplicities. The latter are sent in real time to the Central Trigger Processor (CTP) where the Level-1 decision is made. On receipt of a Level-1 Accept, Readout Driver Modules (RODs), provide intermediate results to the data acquisition (DAQ) system for monitoring and diagnostic purpose. RoI information is sent to the RoI builder (RoIB) to help reduce the amount of data required for the Level-2 Trigger The Level-1 Calorimeter Trigger System at the test beam consisted of 1 Preprocessor module, 1 Cluster Processor Module, 1 Jet/Energy Module and 2 Common Merger Modules. Calorimeter energies were sucessfully handled thourghout the chain and trigger object sent to the CTP. Level-1 Accepts were sucessfully produced and used to drive the readout path. Online diagno...

  12. The H1 liquid argon calorimeter system

    International Nuclear Information System (INIS)

    Andrieu, B.; Babayev, A.; Ban, J.

    1993-06-01

    The liquid argon calorimeter of the H1 detector presently taking data at the HERA ep - collider at DESY, Hamburg, is described here. The main physics requirements and the most salient design features relevant to this calorimeter are given. The aim to have smooth and hermetic calorimetric coverage over the polar angular range 4 ≤ θ ≤ 154 is achieved by a single liquid argon cryostat containing calorimeter stacks structured in wheels and octants for easy handling. The absorber materials used are lead in the electromagnetic part and stainless steel in the hadronic part. The read-out system is pipelined to reduce the dead time induced by the high trigger rate expected at the HERA collider where consecutive bunches are separated in time by 96 ns. The main elements of the calorimeter, such as the cryostat, with its associated cryogenics, the stack modules, the read-out, calibration and trigger electronics as well as the data acquisition system are described. Performance results from data taken in calibration runs with full size H1 calorimeter stacks at a CERN test beam, as well as results from data collected with the complete H1 detector using cosmic rays during the initial phase of ep operations are presented. The observed energy resolutions and linearities are well in agreement with the requirements. (orig.)

  13. Combined assessment of DYRK1A, BDNF and homocysteine levels as diagnostic marker for Alzheimer's disease.

    Science.gov (United States)

    Janel, N; Alexopoulos, P; Badel, A; Lamari, F; Camproux, A C; Lagarde, J; Simon, S; Feraudet-Tarisse, C; Lamourette, P; Arbones, M; Paul, J L; Dubois, B; Potier, M C; Sarazin, M; Delabar, J M

    2017-06-20

    Early identification of Alzheimer's disease (AD) risk factors would aid development of interventions to delay the onset of dementia, but current biomarkers are invasive and/or costly to assess. Validated plasma biomarkers would circumvent these challenges. We previously identified the kinase DYRK1A in plasma. To validate DYRK1A as a biomarker for AD diagnosis, we assessed the levels of DYRK1A and the related markers brain-derived neurotrophic factor (BDNF) and homocysteine in two unrelated AD patient cohorts with age-matched controls. Receiver-operating characteristic curves and logistic regression analyses showed that combined assessment of DYRK1A, BDNF and homocysteine has a sensitivity of 0.952, a specificity of 0.889 and an accuracy of 0.933 in testing for AD. The blood levels of these markers provide a diagnosis assessment profile. Combined assessment of these three markers outperforms most of the previous markers and could become a useful substitute to the current panel of AD biomarkers. These results associate a decreased level of DYRK1A with AD and challenge the use of DYRK1A inhibitors in peripheral tissues as treatment. These measures will be useful for diagnosis purposes.

  14. Involvement of nitrergic system of CA1in harmane induced learning and memory deficits.

    Science.gov (United States)

    Nasehi, Mohammad; Piri, Morteza; Abdollahian, Mojgan; Zarrindast, Mohammad Reza

    2013-01-17

    Harmane (HA) is a β-carboline alkaloid derived from the Peganum harmala plant which induces memory impairment. On the other hand some of the investigations showed that β-carboline alkaloids inhibit NO production. Thus, the aim of the present study was to investigate the role of nitrergic system of the dorsal hippocampus (CA1) in HA-induced amnesia in male adult mice. One-trial step-down passive avoidance and hole-board apparatuses were used for the assessment of memory retrieval and exploratory behaviors respectively. The data indicated that pre-training intraperitoneal (i.p.) administration of HA (12 and 16 mg/kg) decreased memory acquisition. Sole pre-training or pre-testing administration of L-NAME, a nitric oxide synthesis inhibitor (5, 10 and 15 μg/mice, intra-CA1) did not alter memory retrieval. On the other hand, pre-training (10 and 15 μg/mice, intra-CA1) and pre-testing (5, 10 μg/mice, intra-CA1) injections of L-NAME restored HA-induced amnesia (16 mg/kg, i.p.). Furthermore, neither sole pre-training nor pre-testing administration of l-arginine, a NO precursor (3, 6 and 9 μg/mice, intra-CA1), altered memory retrieval. In addition, pre-testing (6 and 9 μg/mice, intra-CA1), but not pre-training, injection of l-arginine increased HA-induced amnesia (16 mg/kg, i.p.). These results suggest that the nitrergic system of CA1 is involved in HA-induced amnesia. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Reliability of ^1^H NMR analysis for assessment of lipid oxidation at frying temperatures

    Science.gov (United States)

    The reliability of a method using ^1^H NMR analysis for assessment of oil oxidation at a frying temperature was examined. During heating and frying at 180 °C, changes of soybean oil signals in the ^1^H NMR spectrum including olefinic (5.16-5.30 ppm), bisallylic (2.70-2.88 ppm), and allylic (1.94-2.1...

  16. Preliminary Assessment of JERS-1 SAR to Discriminating Boreal Landscape Features for the Boreal Forest Mapping Project

    Science.gov (United States)

    McDonald, Kyle; Williams, Cynthia; Podest, Erika; Chapman, Bruce

    1999-01-01

    This paper presents an overview of the JERS-1 North American Boreal Forest Mapping Project and a preliminary assessment of JERS-1 SAR imagery for application to discriminating features applicable to boreal landscape processes. The present focus of the JERS-1 North American Boreal Forest Mapping Project is the production of continental scale wintertime and summertime SAR mosaics of the North American boreal forest for distribution to the science community. As part of this effort, JERS-1 imagery has been collected over much of Alaska and Canada during the 1997-98 winter and 1998 summer seasons. To complete the mosaics, these data will be augmented with data collected during previous years. These data will be made available to the scientific community via CD ROM containing these and similar data sets compiled from companion studies of Asia and Europe. Regional landscape classification with SAR is important for the baseline information it will provide about distribution of woodlands, positions of treeline, current forest biomass, distribution of wetlands, and extent of major rivercourses. As well as setting the stage for longer term change detection, comparisons across several years provides additional baseline information about short-term landscape change. Rapid changes, including those driven by fire, permafrost heat balance, flooding, and insect outbreaks can dominate boreal systems. We examine JERS-1 imagery covering selected sites in Alaska and Canada to assess quality and applicability to such relevant ecological and hydrological issues. The data are generally of high quality and illustrate many potential applications. A texture-based classification scheme is applied to selected regions to assess the applicability of these data for distinguishing distribution of such landcover types as wetland, tundra, woodland and forested landscapes.

  17. CAD-based Monte Carlo program for integrated simulation of nuclear system SuperMC

    International Nuclear Information System (INIS)

    Wu, Y.; Song, J.; Zheng, H.; Sun, G.; Hao, L.; Long, P.; Hu, L.

    2013-01-01

    SuperMC is a (Computer-Aided-Design) CAD-based Monte Carlo (MC) program for integrated simulation of nuclear systems developed by FDS Team (China), making use of hybrid MC-deterministic method and advanced computer technologies. The design aim, architecture and main methodology of SuperMC are presented in this paper. The taking into account of multi-physics processes and the use of advanced computer technologies such as automatic geometry modeling, intelligent data analysis and visualization, high performance parallel computing and cloud computing, contribute to the efficiency of the code. SuperMC2.1, the latest version of the code for neutron, photon and coupled neutron and photon transport calculation, has been developed and validated by using a series of benchmarking cases such as the fusion reactor ITER model and the fast reactor BN-600 model

  18. National Ignition Facility subsystem design requirements transportation and handling, SSDR 1.1.1.3.2

    International Nuclear Information System (INIS)

    Yakuma, S.; McNairy, R.

    1996-01-01

    This Subsystem Design Requirement document is a development specification that establishes the performance, design, development, and test requirements for the Transportation ampersand Material Handling Systems (WBS 1.1.1.3.2) of the NIF Laser System (WBS 1.3 and 1.4). The NIF is a multi-pass, 192-beam, high-power, neodymium-glass laser that meets requirements set forth in the NIF SDR 002 (Laser System). 5 figs

  19. Assessment of epicutaneous testing of a monovalent Influenza A (H1N1 2009 vaccine in egg allergic patients

    Directory of Open Access Journals (Sweden)

    Pitt Tracy

    2011-02-01

    Full Text Available Abstract Background H1N1 is responsible for the first influenza pandemic in 41 years. In the fall of 2009, an H1N1 vaccine became available in Canada with the hopes of reducing the overall effect of the pandemic. The purpose of this study was to assess the safety of administering 2 different doses of a monovalent split virus 2009 H1N1 vaccine in egg allergic patients. Methods Patients were skin tested to the H1N1 vaccine in the outpatient paediatric and adult allergy and immunology clinics of the Health Sciences Centre and Children's Hospital of Winnipeg, Manitoba Canada. Individuals Results A total of 61 patients with egg allergy (history of an allergic reaction to egg with either positive skin test &/or specific IgE to egg >0.35 Ku/L were referred to our allergy clinics for skin testing to the H1N1 vaccine. 2 patients were excluded, one did not have a skin prick test to the H1N1 vaccine (only vaccine administration and the other passed an egg challenge during the study period. Ages ranged from 1 to 27 years (mean 5.6 years. There were 41(69.5% males and 18(30.5% females. All but one patient with a history of egg allergy, positive skin test to egg and/or elevated specific IgE level to egg had negative skin tests to the H1N1 vaccine. The 58 patients with negative skin testing to the H1N1 vaccine were administered the vaccine and observed for 30 minutes post vaccination with no adverse results. The patient with the positive skin test to the H1N1 vaccine was also administered the vaccine intramuscularly with no adverse results. Conclusions Despite concern regarding possible anaphylaxis to the H1N1 vaccine in egg allergic patients, in our case series 1/59(1.7% patients with sensitization to egg were also sensitized to the H1N1 vaccine. Administration of the H1N1 vaccine in egg allergic patients with negative H1N1 skin tests and observation is safe. Administering the vaccine in a 1 or 2 dose protocol without skin testing is a reasonable alternative

  20. Emerging nuclear energy systems: Economic challenge: Revision 1

    International Nuclear Information System (INIS)

    Nuckolls, J.H.

    1986-01-01

    Future nuclear energy systems may achieve substantially lower energy costs than those of existing fossil energy systems and comparable capital costs. Such low cost nuclear energy would provide a strong economic incentive to minimize the use of fossil fuels. If these low cost nuclear energy systems emerge in the next few decades, 21st century civilization may be able to avert potentially disastrous CO 2 induced global climate changes. 12 refs., 1 fig

  1. Experience of superconducting current feeders system of SST-1

    International Nuclear Information System (INIS)

    Gupta, N.C.; Garg, A.; Sonara, D.

    2014-01-01

    The superconducting current feeder system for SST-1 which has been installed and commissioned recently along with SST-1, felicitates to energize the SST-1. The CFS consists of ten pairs of 10,000 Ampere (A) rating helium vapor cooled conventional current leads, interconnecting Cu-SC joints, three numbers of cryo-compatible SC feeders ducts, current leads assembly chamber, hydraulic network and three numbers of joint boxes operated at different current rating to charge Toroidal Field and Poloidal Field coils separately. During the last three campaigns, it was possible to achieve a controlled cool down up to 4 K and showed its rated operational performance. Actively cooled liquid nitrogen shield showed temperature profile in the temperature range of 80-85K and the whole system was evacuated up to 6x10 -6 mbar. The measured LHe consumption rates from TF VCCL were 0.3 g/s and 0.35 g/s at zero current and 1 kA respectively. (author)

  2. Pelvimetry and patient acceptability compared between open 0.5-T and closed 1.5-T MR systems

    International Nuclear Information System (INIS)

    Michel, Sven C.A.; Treiber, Karl; Marincek, Borut; Kubik-Huch, Rahel A.; Rake, Annett; Chaoui, Rabih; Keller, Thomas M.; Goetzmann, Lutz; Seifert, Burkhardt; Ferrazzini, Mattia

    2002-01-01

    Our objective was to compare maternal pelvimetry and patient acceptability between open low-field (0.5-T) and closed 1.5-T MR systems. Thirty women referred for pelvimetry (pregnant: n=15) were scanned twice in the supine position, once in the vertical open system and once in the closed system. Each patient completed a comfort and acceptability questionnaire. Pelvimetric and questionnaire data were compared between systems. Total scan time was double in the open system (7:52±1:47 vs 3:12±1:20 min). Poor image quality in the open system prevented assessment of interspinous and intertuberous diameters in one woman and all measurements in another, both pregnant, with abdominal circumferences >120 cm. The open system was much more acceptable in terms of claustrophobia and confinement (both p<0.01). Claustrophobia interrupted one closed examination. Thirty-three percent of pregnant women in both systems reported fear of fetal harm. Sixty percent of all women preferred the open system, 7% the closed system, and 33% had no preference. Limits of agreement of 3-5% from the mean for all diameters confirmed good pelvimetric reproducibility. Women's preference for open-system MR pelvimetry is feasible with abdominal circumferences ≤120 cm. (orig.)

  3. Pelvimetry and patient acceptability compared between open 0.5-T and closed 1.5-T MR systems

    Energy Technology Data Exchange (ETDEWEB)

    Michel, Sven C.A.; Treiber, Karl; Marincek, Borut; Kubik-Huch, Rahel A. [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Rake, Annett; Chaoui, Rabih; Keller, Thomas M. [Department of Obstetrics, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetzmann, Lutz [Institute of Psychosocial Medicine, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Seifert, Burkhardt [Department of Biostatistics, University Hospital Zurich, Sumatrastrasse 30, 8006 Zurich (Switzerland); Department of Biostatistics, University Hospital Zurich, Sumatrastrasse 30, 8006 Zurich (Switzerland); Ferrazzini, Mattia [Department of Otorhinolaryngology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2002-12-01

    Our objective was to compare maternal pelvimetry and patient acceptability between open low-field (0.5-T) and closed 1.5-T MR systems. Thirty women referred for pelvimetry (pregnant: n=15) were scanned twice in the supine position, once in the vertical open system and once in the closed system. Each patient completed a comfort and acceptability questionnaire. Pelvimetric and questionnaire data were compared between systems. Total scan time was double in the open system (7:52{+-}1:47 vs 3:12{+-}1:20 min). Poor image quality in the open system prevented assessment of interspinous and intertuberous diameters in one woman and all measurements in another, both pregnant, with abdominal circumferences >120 cm. The open system was much more acceptable in terms of claustrophobia and confinement (both p<0.01). Claustrophobia interrupted one closed examination. Thirty-three percent of pregnant women in both systems reported fear of fetal harm. Sixty percent of all women preferred the open system, 7% the closed system, and 33% had no preference. Limits of agreement of 3-5% from the mean for all diameters confirmed good pelvimetric reproducibility. Women's preference for open-system MR pelvimetry is feasible with abdominal circumferences {<=}120 cm. (orig.)

  4. Statistical evaluation of failures and repairs of the V-1 measuring and control system

    International Nuclear Information System (INIS)

    Laurinec, R.; Korec, J.; Mitosinka, J.; Zarnovican, V.

    1984-01-01

    A failure record card system was introduced for evaluating the reliability of the measurement and control equipment of the V-1 nuclear power plant. The SPU-800 microcomputer system is used for recording data on magnetic tape and their transmission to the central data processing department. The data are used for evaluating the reliability of components and circuits and a selection is made of the most failure-prone components, and the causes of failures are evaluated as are failure identification, repair and causes of outages. The system provides monthly, annual and total assessment data since the system was commissioned. The results of the statistical evaluation of failures are used for planning preventive maintenance and for determining optimal repair intervals. (E.S.)

  5. Maintaining the Uranium Resources Assessment Data System and assessing the 1990 US uranium potential resources

    International Nuclear Information System (INIS)

    McCammon, R.B.; Finch, W.I.; Grundy, W.D.; Pierson, C.T.

    1991-01-01

    The Energy Information Administration's (EIA) Uranium Resource Assessment Data System contains information on potential resources (undiscovered) of uranium in the United States. The purpose of this report is: (1) to describe the work carried out to maintain and update the Uranium Resource Assessment Data (URAD) System, (2) to assess the 1990 US uranium potential resources in various cost categories, and (3) to identify problems and to recommend changes that are needed to improve the URAD System. 13 refs., 5 figs., 4 tabs

  6. PAC1 receptor (ADCYAP1R1 genotype and problematic alcohol use in a sample of young women

    Directory of Open Access Journals (Sweden)

    Dragan WŁ

    2017-06-01

    Full Text Available Wojciech Łukasz Dragan,1 Piotr M Czerski,2 Małgorzata Dragan3 1The Interdisciplinary Center for Behavior Genetic Research, Faculty of Psychology, University of Warsaw, Warsaw, 2Laboratory of Psychiatric Genetics, Poznan University of Medical Sciences, Poznan, 3Faculty of Psychology, University of Warsaw, Warsaw, Poland Background: Recent studies revealed the role of the PAC1 (ADCYAP1R1 gene variability in vulnerability to posttraumatic stress disorder in women. Due to the relatively high comorbidity of posttraumatic stress disorder and substance use disorder, we hypothesized about possible associations between PAC1 gene and problematic alcohol use. Method: The sample studied consisted of 491 women aged 18–28 years (mean age =21.76 years; SD =1.83 and the Alcohol Use Disorders Identification Test was used to assess drinking problems. We successfully genotyped 17 single-nucleotide polymorphisms in the PAC1 gene. Results: Single locus analysis revealed a significant (after correction for multiple testing association between intronic polymorphism rs2302475 and problematic alcohol use (P=0.00048; recessive model. This result was strengthened by the haplotype analysis (P=0.00379. Conclusion: Our results suggest that the PACAP/PAC1 signaling system is implicated in the development of problematic alcohol use in women. Keywords: problematic alcohol use, PAC1 gene, AUDIT, HPA axis

  7. The Doubting System 1: Evidence for automatic substitution sensitivity.

    Science.gov (United States)

    Johnson, Eric D; Tubau, Elisabet; De Neys, Wim

    2016-02-01

    A long prevailing view of human reasoning suggests severe limits on our ability to adhere to simple logical or mathematical prescriptions. A key position assumes these failures arise from insufficient monitoring of rapidly produced intuitions. These faulty intuitions are thought to arise from a proposed substitution process, by which reasoners unknowingly interpret more difficult questions as easier ones. Recent work, however, suggests that reasoners are not blind to this substitution process, but in fact detect that their erroneous responses are not warranted. Using the popular bat-and-ball problem, we investigated whether this substitution sensitivity arises out of an automatic System 1 process or whether it depends on the operation of an executive resource demanding System 2 process. Results showed that accuracy on the bat-and-ball problem clearly declined under cognitive load. However, both reduced response confidence and increased response latencies indicated that biased reasoners remained sensitive to their faulty responses under load. Results suggest that a crucial substitution monitoring process is not only successfully engaged, but that it automatically operates as an autonomous System 1 process. By signaling its doubt along with a biased intuition, it appears System 1 is "smarter" than traditionally assumed.

  8. A 1J LD pumped Nd:YAG pulsed laser system

    Science.gov (United States)

    Yi, Xue-bin; Wang, Bin; Yang, Feng; Li, Jing; Liu, Ya-Ping; Li, Hui-Jun; Wang, Yu; Chen, Ren

    2017-11-01

    A 1J LD pumped Nd;YAG pulsed laser was designed. The laser uses an oscillation and two-staged amplification structure, and applies diode bar integrated array as side-pump. The TEC temperature control device combing liquid cooling system is organized to control the temperature of the laser system. This study also analyzed the theoretical threshold of working material, the effect of thermal lens and the basic principle of laser amplification. The results showed that the laser system can achieve 1J, 25Hz pulse laser output, and the laser pulse can be output at two width: 6-7ns and 10ns, respectively, and the original beam angle is 1.2mrad. The laser system is characterized by small size, light weight, as well as good stability, which make it being applied in varied fields such as photovoltaic radar platform and etc

  9. A Level 1+ Probabilistic Safety Assessment of the high flux Australian reactor. Vol. 2. Appendix C: System analysis models and results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This section contains the results of the quantitative system/top event analysis. Section C. 1 gives the basic event coding scheme. Section C.2 shows the master frequency file (MFF), which contains the split fraction names, the top events they belong to, the mean values of the uncertainty distribution that is generated by the Monte Carlo quantification in the System Analysis module of RISKMAN, and a brief description of each split fraction. The MFF is organized by the systems modeled, and within each system, the top events associated with the system. Section C.3 contains the fault trees developed for the system/top event models and the RISKMAN reports for each of the system/top event models. The reports are organized under the following system headings: Compressed/Service Air Supply (AIR); Containment Isolation System (CIS); Heavy Water Cooling System (D20); Emergency Core Cooling System (ECCS); Electric Power System (EPS); Light Water Cooling system (H20); Helium Gas System (HE); Mains Water System (MW); Miscellaneous Top Events (MISC); Operator Actions (OPER) Reactor Protection System (RPS); Space Conditioner System (SCS); Condition/Status Switch (SWITCH); RCB Ventilation System (VENT); No. 1 Storage Block Cooling System (SB)

  10. A Level 1+ Probabilistic Safety Assessment of the high flux Australian reactor. Vol. 2. Appendix C: System analysis models and results

    International Nuclear Information System (INIS)

    1998-01-01

    This section contains the results of the quantitative system/top event analysis. Section C. 1 gives the basic event coding scheme. Section C.2 shows the master frequency file (MFF), which contains the split fraction names, the top events they belong to, the mean values of the uncertainty distribution that is generated by the Monte Carlo quantification in the System Analysis module of RISKMAN, and a brief description of each split fraction. The MFF is organized by the systems modeled, and within each system, the top events associated with the system. Section C.3 contains the fault trees developed for the system/top event models and the RISKMAN reports for each of the system/top event models. The reports are organized under the following system headings: Compressed/Service Air Supply (AIR); Containment Isolation System (CIS); Heavy Water Cooling System (D20); Emergency Core Cooling System (ECCS; Electric Power System (EPS); Light Water Cooling system (H20); Helium Gas System (HE); Mains Water System (MW); Miscellaneous Top Events (MISC); Operator Actions (OPER) Reactor Protection System (RPS); Space Conditioner System (SCS); Condition/Status Switch (SWITCH); RCB Ventilation System (VENT); No. 1 Storage Block Cooling System (SB)

  11. Probing the TRAPPIST-1 System with K2, JWST, and Beyond

    Science.gov (United States)

    Luger, Rodrigo; Lustig-Yaeger, Jacob; Agol, Eric; TRAPPIST-1 Collaboration

    2018-01-01

    I will discuss recent work I have done to characterize TRAPPIST-1, a nearby exoplanet system hosting seven terrestrial-size planets, three of which are in the habitable zone. In the first part of this talk, I will report on my efforts to constrain the orbital properties of the smallest and farthest out planet in the system, TRAPPIST-1h, from K2 data de-trended with my systematics correction pipeline, EVEREST. I will further discuss how the detection of TRAPPIST-1h with K2 confirmed the intricate resonant structure of the system, whose planets are all linked to their neighbors via three-body Laplace resonances. This is the longest known chain in any exoplanet system and holds important clues for the formation and migration of the TRAPPIST-1 planets. In the second part of this talk, I will discuss ongoing work to characterize the TRAPPIST-1 system via planet-planet occultations (PPOs), events during which one planet occults the disk of another, imparting a small photometric signal as its thermal or reflected light is blocked. Because of the extreme coplanarity of the system, PPOs should occur on average 1 - 2 times per day in TRAPPIST-1. I will discuss how the upcoming James Webb Space Telescope (JWST) will likely be able to detect PPOs in this system in the mid-infrared, and how these can be used to place exquisite constraints on the masses, eccentricities, and mutual inclinations of its planets. I will also show how photodynamical modeling of these events can eventually be used to reveal a planet's day/night temperature contrast, infer various atmospheric properties, and construct crude two-dimensional surface maps of alien worlds.

  12. 1 nA beam position monitoring system

    International Nuclear Information System (INIS)

    Ursic, R.; Flood, R.; Piller, C.

    1997-01-01

    A system has been developed at Jefferson Lab for measuring transverse position of very low current beams delivered to the Experimental Hall B of the Continuous Electron Beam Accelerator Facility (CEBAF). At the heart of the system is a position sensitive cavity operating at 1497 MHz. The cavity utilizes a unique design which achieves a high sensitivity to beam position at a relatively low cavity Q. The cavity output RF signal is processed using a down-converter and a commercial lock-in amplifier operating at 100 kHz. The system interfaces with a VME based EPICS control system using the IEEE, 488 bus. The main features of the system are simple and robust design, and wide dynamic range capable of handling beam currents from 1 nA to 1000 nA with an expected resolution better than 100 μm. This paper outlines the design of the system

  13. Techno-economic feasibility analysis of 1 MW photovoltaic grid connected system in Oman

    Directory of Open Access Journals (Sweden)

    Hussein A. Kazem

    2017-09-01

    Full Text Available Solar photovoltaic panels (PV face many challenges in the Sultanate of Oman. These challenges include costs, policy and technical development. With the growing needs of the Sultanate in the energy sector, Grid Connected PV (GCPV system could help in reducing peak load demand and offer an alternative energy source. This study aims to numerically discover the optimal configuration for a 1 MW GCPV plant in Adam city. Real time data, on hour-by-hour basis, from the location are used to ensure highest accuracy. The simulation not only is set for technical evaluation but economic as well. Investment in GCPV technology needs a bigger push both by research, development and policy. The assessment results show that the PV technology investment is very promising in this site whereas the annual yield factor of the system is 1875.1 kW h/kW p. Meanwhile, the capacity factor of the proposed system is 21.7%. The cost of energy found for the plant is around 0.2258 USD/kW h which is economically feasible and shows great promise.

  14. Active materials for automotive adaptive forward lighting Part 1: system requirements vs. material properties

    Science.gov (United States)

    Keefe, Andrew C.; Browne, Alan L.; Johnson, Nancy L.

    2011-04-01

    Adaptive Frontlighting Systems (AFS in GM usage) improve visibility by automatically optimizing the beam pattern to accommodate road, driving and environmental conditions. By moving, modifying, and/or adding light during nighttime, inclement weather, or in sharp turns, the driver is presented with dynamic illumination not possible with static lighting systems The objective of this GM-HRL collaborative research project was to assess the potential of active materials to decrease the cost, mass, and packaging volume of current electric stepper-motor AFS designs. Solid-state active material actuators, if proved suitable for this application, could be less expensive than electric motors and have lower part count, reduced size and weight, and lower acoustic and EMF noise1. This paper documents Part 1 of the collaborative study, assessing technically mature, commercially available active materials for use as actuators. Candidate materials should reduce cost and improve AFS capabilities, such as increased angular velocity on swivel. Additional benefits to AFS resulting from active materials actuators were to be identified as well such as lower part count. In addition, several notional approaches to AFS were documented to illustrate the potential function, which is developed more fully in Part 2. Part 1 was successful in verifying the feasibility of using two active materials for AFS: shape memory alloys, and piezoelectrics. In particular, this demonstration showed that all application requirements including those on actuation speed, force, and cyclic stability to effect manipulation of the filament assembly and/or the reflector could be met by piezoelectrics (as ultrasonic motors) and SMA wire actuators.

  15. Interleukin-1 (IL-1 system gene expression in granulosa cells: kinetics during terminal preovulatory follicle maturation in the mare

    Directory of Open Access Journals (Sweden)

    Gérard Nadine

    2003-05-01

    Full Text Available Abstract Background A growing body of evidences suggests that the ovary is a site of inflammatory reactions, and thus, ovarian cells could represent sources and targets of the interleukin-1 (IL-1 system. The purpose of this study was to examine the IL-1 system gene expressions in equine granulosa cells, and to study the IL-1β content in follicular fluid during the follicle maturation. For this purpose, granulosa cells and follicular fluids were collected from the largest follicle at the early dominance stage (diameter 24 ± 3 mm or during the preovulatory maturation phase, at T0 h, T6 h, T12 h, T24 h and T34 h after induction of ovulation. Cells were analysed by RT-PCR and follicular fluids were studied by gel electrophoresis and immunoblotting. Results We demonstrated that interleukin-1β (IL-1β, interleukin-1 receptor 2 (IL-1R2 and interleukin-1 receptor antagonist (IL-1RA genes are expressed in equine granulosa cells. We observed that the IL-1β and IL-1RA mRNA content changed in granulosa cells during the terminal follicular maturation whereas IL-1R2 mRNA did not vary. In follicular fluid, IL-1β content fluctuated few hours after induction of ovulation. Conclusions The expression of IL-1β gene in granulosa cells and the follicular fluid IL-1β content seem to be regulated by gonadotropins suggesting that IL-1β could be an intermediate paracrine factor involved in ovulation.

  16. Glucagon-like Peptide-1 and the Central/Peripheral Nervous System

    DEFF Research Database (Denmark)

    Muscogiuri, Giovanna; DeFronzo, Ralph A; Gastaldelli, Amalia

    2017-01-01

    Glucagon-like peptide-1 (GLP-1) is released in response to meals and exerts important roles in the maintenance of normal glucose homeostasis. GLP-1 is also important in the regulation of neurologic and cognitive functions. These actions are mediated via neurons in the nucleus of the solitary trac...... human trials report a neuroprotective effect of GLP-1-RAs in Alzheimer's and Parkinson's disease. In this review, we discuss the role of GLP-1 and GLP-1-RAs in the nervous system with focus on GLP-1 actions on appetite regulation, glucose homeostasis, and neuroprotection....

  17. Deficiency of α-1-antitrypsin influences systemic iron homeostasis

    Directory of Open Access Journals (Sweden)

    Ghio AJ

    2013-01-01

    Full Text Available Andrew J Ghio,1 Joleen M Soukup,1 Judy H Richards,1 Bernard M Fischer,2 Judith A Voynow,2 Donald E Schmechel31US Environmental Protection Agency, Chapel Hill, NC, USA; 2Division of Pediatric Pulmonary Medicine, Department of Pediatrics,3Joseph and Kathleen Bryan Alzheimer Disease Research Center, Department of Medicine (Neurology, Duke University Medical Center, Durham, NC, USAAbstract: There is evidence that proteases and antiproteases participate in the iron homeostasis of cells and living systems. We tested the postulate that α-1 antitrypsin (A1AT polymorphism and the consequent deficiency of this antiprotease in humans are associated with a systemic disruption in iron homeostasis. Archived plasma samples from Alpha-1 Foundation (30 MM, 30 MZ, and 30 ZZ individuals were analyzed for A1AT, ferritin, transferrin, and C-reactive protein (CRP. Plasma samples were also assayed for metals using inductively coupled plasma atomic emission spectroscopy (ICPAES. Plasma levels of A1AT in MZ and ZZ individuals were approximately 60% and 20% of those for MM individuals respectively. Plasma ferritin concentrations in those with the ZZ genotype were greater relative to those individuals with either MM or MZ genotype. Plasma transferrin for MM, MZ, and ZZ genotypes showed no significant differences. Linear regression analysis revealed a significant (negative relationship between plasma concentrations of A1AT and ferritin while that between A1AT and transferrin levels was not significant. Plasma CRP concentrations were not significantly different between MM, MZ, and ZZ individuals. ICPAES measurement of metals confirmed elevated plasma concentrations of nonheme iron among ZZ individuals. Nonheme iron concentrations correlated (negatively with levels of A1AT. A1AT deficiency is associated with evidence of a disruption in iron homeostasis with plasma ferritin and nonheme iron concentrations being elevated among those with the ZZ genotype.Keywords: α-1

  18. Validating the JobFit system functional assessment method

    Energy Technology Data Exchange (ETDEWEB)

    Jenny Legge; Robin Burgess-Limerick

    2007-05-15

    Workplace injuries are costing the Australian coal mining industry and its communities $410 Million a year. This ACARP study aims to meet those demands by developing a safe, reliable and valid pre-employment functional assessment tool. All JobFit System Pre-Employment Functional Assessments (PEFAs) consist of a musculoskeletal screen, balance test, aerobic fitness test and job-specific postural tolerances and material handling tasks. The results of each component are compared to the applicant's job demands and an overall PEFA score between 1 and 4 is given with 1 being the better score. The reliability study and validity study were conducted concurrently. The reliability study examined test-retest, intra-tester and inter-tester reliability of the JobFit System Functional Assessment Method. Overall, good to excellent reliability was found, which was sufficient to be used for comparison with injury data for determining the validity of the assessment. The overall assessment score and material handling tasks had the greatest reliability. The validity study compared the assessment results of 336 records from a Queensland underground and open cut coal mine with their injury records. A predictive relationship was found between PEFA score and the risk of a back/trunk/shoulder injury from manual handling. An association was also found between PEFA score of 1 and increased length of employment. Lower aerobic fitness test results had an inverse relationship with injury rates. The study found that underground workers, regardless of PEFA score, were more likely to have an injury when compared to other departments. No relationship was found between age and risk of injury. These results confirm the validity of the JobFit System Functional Assessment method.

  19. Dimensionality and integrals of motion of the Trappist-1 planetary system

    Science.gov (United States)

    Floß, Johannes; Rein, Hanno; Brumer, Paul

    2018-04-01

    The number of isolating integrals of motion of the Trappist-1 system - a late M-dwarf orbited by seven Earth-sized planets - was determined numerically, using an adapted version of the correlation dimension method. It was found that over the investigated time-scales of up to 20 000 years the number of isolating integrals of motion is the same as one would find for a system of seven non-interacting planets - despite the fact that the planets in the Trappist-1 system are strongly interacting. Considering perturbed versions of the Trappist-1 system shows that the system may occupy an atypical part of phase-space with high stability. These findings are consistent with earlier studies.

  20. Assessment of ICARE/CATHARE V1mod1 and V1 applications to full scale studies

    International Nuclear Information System (INIS)

    Chatelard, P.; Barre, F.; Mutelle, H.

    2001-01-01

    The objective initially assigned to the ICARE/CATHARE V1mod1 validation task was to draw a synthesis of the ability of the code to correctly reproduce the main physical processes occurring during severe accidents. Therefore, both the domain in which the ICARE/CATHARE V1mod1 predictions are satisfactory (good confidence level) and, conversely, the identification of the main code deficiencies have to be highlighted. After a brief recall of the validation strategy and the current status of the work, this paper summarizes the main lessons which were drawn by IPSN from the validation activity which was conducted during the last two years (in 2000-2001) in the particular framework of the Users' Club (both IPSN and several foreign partners were involved in this task, under the management of IPSN). (authors)

  1. Fragrance material review on 1-(5,5-dimethylcyclohexen-1-yl)pent-4-en-1-one.

    Science.gov (United States)

    Scognamiglio, J; Letizia, C S; Api, A M

    2013-12-01

    A toxicologic and dermatologic review of 1-(5,5-dimethylcyclohexen-1-yl)pent-4-en-1-one when used as a fragrance ingredient is presented. 1-(5,5-Dimethylcyclohexen-1-yl)pent-4-en-1-one is a member of the fragrance structural group Alkyl Cyclic Ketones. These fragrances can be described as being composed of an alkyl, R1, and various substituted and bicyclic saturated or unsaturated cyclic hydrocarbons, R2, in which one of the rings may include up to 12 carbons. Alternatively, R2 may be a carbon bridge of C2-C4 carbon chain length between the ketone and cyclic hydrocarbon. This review contains a detailed summary of all published and unpublished toxicology and dermatology papers that are related to this individual fragrance ingredient and is not intended as a stand-alone document. Available data for 1-(5,5-dimethylcyclohexen-1-yl)pent-4-en-1-one were evaluated then summarized and includes physical properties, acute toxicity, skin irritation, mucous membrane (eye) irritation, skin sensitization, and photoallergy data. A safety assessment of the entire Alkyl Cyclic Ketones will be published simultaneously with this document; please refer to Belsito et al. (Belsito, D., Bickers, D., Bruze, M., Calow, P., Dagli, M., Fryer, A.D., Greim, H., Miyachi, Y., Saurat, J.H., Sipes, I.G., 2013. A Toxicologic and Dermatologic Assessment of Alkyl Cyclic Ketones When Used as Fragrance Ingredients (submitted for publication)) for an overall assessment of the safe use of this material and all Alkyl Cyclic Ketones in fragrances. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. A National Energy-Water System Assessment Framework (NEWS): Synopsis of Stage 1 Research Strategy and Results

    Science.gov (United States)

    Vorosmarty, C. J.; Miara, A.; Macknick, J.; Newmark, R. L.; Cohen, S.; Sun, Y.; Tidwell, V. C.; Corsi, F.; Melillo, J. M.; Fekete, B. M.; Proussevitch, A. A.; Glidden, S.; Suh, S.

    2017-12-01

    The focus of this talk is on climate adaptation and the reliability of power supply infrastructure when viewed through the lens of strategic water issues. Power supply is critically dependent upon water resources, particularly to cool thermoelectric plants, making the sector particularly sensitive to any shifts in the geography or seasonality of water supply. We report on results from an NSF-Funded Water Sustainability and Climate effort aimed at uncovering key energy and economic system vulnerabilities. We have developed the National Energy-Water System assessment framework (NEWS) to systematically evaluate: a) the performance of the nation's electricity sector under multiple climate scenarios; b) the feasibility of alternative pathways to improve climate adaptation; and, c) the impacts of energy technology and investment tradeoffs on the economic productivity, water availability and aquatic ecosystem condition. Our project combines core engineering and geophysical models (ReEDS [Regional Energy Deployment System], TP2M [Thermoelectric Power and Thermal Pollution], and WBM [Water Balance]) through unique digital "handshake" protocols that operate across different institutions and modeling platforms. Combined system outputs are fed into a regional-to-national scale economic input/output model to evaluate economic consequences of climate constraints, technology choices, and environmental regulation. The impact assessments in NEWS are carried out through a series of climate/energy policy scenario studies to 2050. We find that despite significant climate-water impacts on individual plants, the current US power supply infrastructure shows potential for adaptation to future climates by capitalizing on the size of regional power systems, grid configuration and improvements in thermal efficiencies. However, the magnitude and implications of climate-water impacts vary depending on the configuration of the future power sector. To evaluate future power supply performance, we

  3. Operation of the Upgraded ATLAS Level-1 Central Trigger System

    CERN Document Server

    Glatzer, Julian Maximilian Volker; The ATLAS collaboration

    2015-01-01

    The ATLAS Level-1 Central Trigger (L1CT) system is a central part of ATLAS data-taking and has undergone a major upgrade for Run 2 of the LHC, in order to cope with the expected increase of instantaneous luminosity of a factor of 2 with respect to Run 1. The upgraded hardware offers more flexibility in the trigger decisions due to the double amount of trigger inputs and usable trigger channels. It also provides an interface to the new topological trigger system. Operationally - particularly useful for commissioning, calibration and test runs - it allows concurrent running of up to 3 different sub-detector combinations. In this contribution, we give an overview of the operational software framework of the L1CT system with particular emphasis of the configuration, controls and monitoring aspects. The software framework allows a consistent configuration with respect to the ATLAS experiment and the LHC machine, upstream and downstream trigger processors, and the data acquisition. Trigger and dead-time rates are m...

  4. Waste Receiving and Processing Facility Module 1: Volume 1, Preliminary Design report

    International Nuclear Information System (INIS)

    1992-03-01

    The Preliminary Design Report (Title 1) for the Waste Receiving and Processing (WRAP) Module 1 provides a comprehensive narrative description of the proposed facility and process systems, the basis for each of the systems design, and the engineering assessments that were performed to support the technical basis of the Title 1 design. The primary mission of the WRAP 1 Facility is to characterize and certify contact-handled (CH) waste in 55-gallon drums for disposal. Its secondary function is to certify CH waste in Standard Waste Boxes (SWBs) for disposal. The preferred plan consist of retrieving the waste and repackaging as necessary in the Waste Receiving and Processing (WRAP) facility to certify TRU waste for shipment to the Waste Isolation Pilot Plant (WIPP) in New Mexico. WIPP is a research and development facility designed to demonstrate the safe and environmentally acceptable disposal of TRU waste from National Defense programs. Retrieved waste found to be Low-Level Waste (LLW) after examination in the WRAP facility will be disposed of on the Hanford site in the low-level waste burial ground. The Hanford Site TRU waste will be shipped to the WIPP for disposal between 1999 and 2013

  5. Evaluation System for Pesticides (ESPE). 1. Agricultural pesticides

    NARCIS (Netherlands)

    Emans HJB; Beek MA; Linders JBHJ

    1992-01-01

    In this report a risk assessment or evaluation system for agricultural pesticides is presented, which estimates the hazards for man and environment resulting from the use of these pesticides. The evaluation system has also been placed within the context of the Uniform System for the Evaluation of

  6. Effect of candesartan on prevention (DIRECT-Prevent 1) and progression (DIRECT-Protect 1) of retinopathy in type 1 diabetes: randomised, placebo-controlled trials

    DEFF Research Database (Denmark)

    Chaturvedi, N.; Porta, M.; Klein, R.

    2008-01-01

    of retinopathy in type 1 diabetes. METHODS: Two randomised, double-blind, parallel-design, placebo-controlled trials were done in 309 centres worldwide. Participants with normotensive, normoalbuminuric type 1 diabetes without retinopathy were recruited to the DIRECT-Prevent 1 trial and those with existing...... retinopathy were recruited to DIRECT-Protect 1, and were assigned to candesartan 16 mg once a day or matching placebo. After 1 month, the dose was doubled to 32 mg. Investigators and participants were unaware of the treatment allocation status. The primary endpoints were incidence and progression......BACKGROUND: Results of previous studies suggest that renin-angiotensin system blockers might reduce the burden of diabetic retinopathy. We therefore designed the DIabetic REtinopathy Candesartan Trials (DIRECT) Programme to assess whether candesartan could reduce the incidence and progression...

  7. The ν 1Band System of H-CC-CN (Cyanoacetylene)

    Science.gov (United States)

    Winther, F.; Klee, S.; Mellau, G.; Naı̈m, S.; Mbosei, L.; Fayt, A.

    1996-02-01

    The ν1band system of cyanoacetylene (H-CC-CN) has been observed with an effective resolution of 0.006 cm-1. ν1= 3327.37085(3) cm-1,B1= 0.15149762(2) cm-1,D1= 1.8065(3) × 10-8cm-1. Several hot bands from the statesv5= 1,v6= 1,v7= 1, 2 (l= 0 and 2), 3 (l= 1 and 3), and 4 (l= 0 and 2),v6=v7= 1 (l= 0 and 2), andv6= 1 andv7= 2 (l= 3) have also been observed and analyzed. Many bands show strong local perturbations due to interactions with states which are combinations of the modes 4, 5, 6, and 7. These perturbing states are also described quantitatively, and rovibrational constants are given.

  8. Mesorad dose assessment model. Volume 1. Technical basis

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; Bander, T.J.; Athey, G.F.; Ramsdell, J.V.

    1986-03-01

    MESORAD is a dose assessment model for emergency response applications. Using release data for as many as 50 radionuclides, the model calculates: (1) external doses resulting from exposure to radiation emitted by radionuclides contained in elevated or deposited material; (2) internal dose commitment resulting from inhalation; and (3) total whole-body doses. External doses from airborne material are calculated using semi-infinite and finite cloud approximations. At each stage in model execution, the appropriate approximation is selected after considering the cloud dimensions. Atmospheric processes are represented in MESORAD by a combination of Lagrangian puff and Gaussian plume dispersion models, a source depletion (deposition velocity) dry deposition model, and a wet deposition model using washout coefficients based on precipitation rates

  9. Vapor-liquid equilibria of the water + 1,3-propanediol and water + 1,3-propanediol + lithium bromide systems

    Energy Technology Data Exchange (ETDEWEB)

    Mun, S Y; Lee, H

    1999-12-01

    Vapor-liquid equilibrium data of the water + 1,3-propanediol and water + 1,3-propanediol + lithium bromide systems were measured at 60, 160, 300, and 760 mmHg at temperatures ranging from 315 to 488 K. The apparatus used in this work is a modified still especially designed for the measurement of low-pressure VLE, in which both liquid and vapor are continuously recirculated. For the analysis of salt-containing solutions, a method incorporating refractometry and gravimetry was used. From the experimental measurements, the effect of lithium bromide on the VLE behavior of water + 1,3-propanediol was investigated. The experimental data of the salt-free system were successfully correlated using the Wilson, NRTL, and UNIQUAC models. In addition, the extended UNIQUAC model of Sander et al. was applied to the VLE calculation of salt-containing mixtures.

  10. Fourier transforms related to a root system of rank 1.

    NARCIS (Netherlands)

    Groenevelt, W.G.M.

    2007-01-01

    Abstract : We introduce an algebra $\\mathcal H$ consisting of difference-reflection operators and multiplication operators that can be considered as a q = 1 analogue of Sahi's double affine Hecke algebra related to the affine root system of type $(C^\\vee_1, C_1)$ . We study eigenfunctions of a

  11. Study of complexes of f-block elements-hydroxypyridinone systems: Pt. 1

    International Nuclear Information System (INIS)

    Zhu Daohong

    1988-01-01

    The solution chemistry of Th(IV) with several hydroxypyridinones, 1-hydroxy-2 (1H) -pyridinone (1,2-HOPO) and 3-hydroxy-2 (1H) -pyridinone (3,2-HOPO) has been studied using potentiometric and spectrophotometric methods. The potentiometric measurements are described for the solution containing different ratios of hydroxypyridinones to Th(IV) in 0.10 mol/l KNO 3 solution at 25 deg C. Several complexes of Th(IV) and hydroxypyridinones are formed in the solutions at different systems and pH values. The complexes of Th(1,2-OPO) 3+ ,Th(1,2-OPO) 2 2+ ,Th(1,2-OPO) 3 + and Th(1,2-OPO) 4 are formed at pH3.4, 4.0, 4.7, and 5.8, respectively. It is found that similar complexes are also formed for the system of 3, 2-HOPO and Th(IV), but the buffer region of metal complexation for 1,2-HOPO is lower in pH. The formation constants of the complexes are calculated using a non-linear least wquare program to refine potentiometric titration data by CDC CYBER 170/825 computer. It is found that the formation constants are as follows: logβ 110 =9.3(1), logβ 120 =17.2(4), logβ 130 =23.4(5) and logβ 140 =29.0(1) for Th(IV)-1,2-HOPO system and logβ 110 =10.4(2), logβ 120 =19.2(2), logβ 130 =26.6(6) and logβ 140 =32.4 for Th(IV)-3,2-HOPO system. The pM values of 1,2-HOPO and 3,2-HOPO for Th(IV) are 14.1(2) and 12.5(8) at pH 7.4, [M] T =1μmol/l and [L] T =10μmol/l respectively. These results are to be used in the design and refinement of actinide-specific macro-chelate sequestering agents

  12. Anti-C1q antibodies in systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Orbai, A-M; Truedsson, L; Sturfelt, G

    2015-01-01

    OBJECTIVE: Anti-C1q has been associated with systemic lupus erythematosus (SLE) and lupus nephritis in previous studies. We studied anti-C1q specificity for SLE (vs rheumatic disease controls) and the association with SLE manifestations in an international multicenter study. METHODS: Information...... in combination with anti-dsDNA and low complement was the strongest serological association with renal involvement. These data support the usefulness of anti-C1q in SLE, especially in lupus nephritis....

  13. Clinical outcomes of individualized botulinum neurotoxin type A injection techniques in patients with essential blepharospasm.

    Science.gov (United States)

    Sung, Youngje; Nam, Sang Min; Lew, Helen

    2015-04-01

    To assess the clinical outcomes following botulinum neurotoxin type A (BoNT-A) treatment with an individualized injection technique based on the types of spasms and to compare the results of the individualized injection technique with those of the conventional injection technique in the same patients. From November 2011 to July 2013, 77 BoNT-A injections were performed in 38 patients. Eighteen patients were treated with conventional BoNT-A injections before 2011, and 20 patients were referred to our hospital for unsatisfactory results after a conventional injection technique. We classified the patients by spasm-dominant sites: the lateral orbital area, representing the orbital orbicularis-dominant group (ODG); the glabella, representing the corrugator-dominant group (CDG); and the ptosis, representing the palpebral part of the orbicularis-dominant group (PDG). We increased the injection dose into the spasm-dominant sites of the blepharospasm groups. We assessed subjective symptom scores (functional disability score, FDS) after treatment. This study included 38 patients (26 women, 12 men; mean age, 60.6 ± 10.9 years). There were 21 patients in the ODG, 10 patients in the CDG, and 7 patients in the PDG. Mean ages were 59.7 ± 12.6, 59.8 ± 8.5, and 66.8 ± 9.0 years, and mean BoNT-A injection dose was 38.8 ± 11.2, 38.8 ± 11.2, and 38.8 ± 10.8 U in each group, respectively (p = 0.44, 0.82 Kruskal-Wallis test). Mean FDS after injection was 1.7 ± 0.7 in the ODG, 1.4 ± 0.8 in the CDG, and 1.2 ± 0.3 in the PDG. There were significant differences in reading and job scale among the three groups. In a comparison between the conventional and individualized injection techniques, there was a significant improvement in mean FDS and in the reading scale in the PDG with the individualized injection technique. The success rate was 92.1% in the conventional injection group and 94.1% in the individualized injection group. The individualized injection technique of Bo

  14. WIPP supplementary roof support system, Room 1, Panel 1: Geotechnical field data analysis bi-annual report

    International Nuclear Information System (INIS)

    1992-01-01

    In June 1991, Waste Isolation Division (WID) initiated the design effort to develop a supplementary roof support system to extend the life of Room 1, Panel 1, to allow successful completion of the bin-scale test program. A number of potential options for ground control were considered leading to the finalization of the currently installed roof support system. This highly instrumented system is ''state of the art'' for mine ground control and will provide extensive geotechnical data. The system is an innovative blend of several standard techniques and incorporates five of the suggestions made by the Geotechnical Panel in its report of June 1991, on the effective life of Rooms in Panel 1. The design was subjected to an exhaustive scrutiny by two formal Design Review Panels and was approved based on reviewed design documents, on-site observations at the WIPP underground facility, and detailed discussions with members of the design team. The original requirement was to have only a section of the room completed in October in preparation for first waste receipt. This goal was met and the relatively complex installation in the entire room was completed in December 1991. The Support System, with all its instrumentation, is now fully operational and generating geotechnical data. Examination of extensometer, closure and load cell data indicate that Room support is performing within the design parameters. All the anchors were initially loaded to approximately 445 kN (1000 lbs). The results of load cell monitoring indicates a steady increase of load on the rock bolts. The anchors installed near the room centerline have shown the greatest increase with the outermost anchors showing little or no load

  15. Toronto's 2-1-1 healthcare services for immigrant populations.

    Science.gov (United States)

    Cortinois, Andrea A; Glazier, Richard H; Caidi, Nadia; Andrews, Gavin; Herbert-Copley, Mary; Jadad, Alejandro R

    2012-12-01

    Although access to information on health services is particularly important for recent immigrants, numerous studies have shown that their use of information and referral services is limited. This study explores the role played by 2-1-1 Toronto in supporting recent immigrants. The study objectives were to (1) understand whether 2-1-1 Toronto is reaching and supporting recent immigrants and (2) gain a better appreciation of the information needs of this population group. A phone survey was conducted in 2005-2006 to collect information on 2-1-1 users' characteristics and levels of satisfaction. Survey data were compared (in 2006) with census data to assess their representativeness. To achieve Objective 2, semistructured qualitative interviews were conducted and analyzed in 2006-2007, with a subset of Spanish-speaking callers. Recent immigrants were overrepresented among 2-1-1 callers. However, the survey population was substantially younger and had higher levels of formal education than the general population. Health-related queries represented almost one third of the total. The survey showed very high levels of satisfaction with the service. Many interviewees described their first experiences with the Canadian healthcare system negatively. Most of them had relied on disjointed, low-quality information sources. They trusted 2-1-1 but had discovered it late. Results are mixed in terms of 2-1-1's support to immigrants. A significant percentage of users do not take full advantage of the service. The service could become the information "entry point" for recent immigrants if it was able to reach them early in the resettlement process. Proactive, community-oriented work and a more creative use of technology could help. Copyright © 2012 American Journal of Preventive Medicine. All rights reserved.

  16. Mechanisms of ultrafast fluorescence depletion spectroscopy and applications to measure slovation dynamics of coummarin 153 in methanol

    International Nuclear Information System (INIS)

    Yang Songqiu; Liu Jianyong; Zhou Panwang; Chen Junsheng; Han Keli; He Guozhong

    2012-01-01

    Subpicosecond fluorescence depletion spectroscopy (FDS) was used to measure the solvation dynamics of coumarin 153 (C153) in methanol. The FDS mechanisms were discussed. A quasi-continuous model was used to describe the solvational relaxation of excited states. The perturbations of the probe pulse on the excited sample system, including up-conversion and stimulated emission, were sufficiently discussed. For a probe molecule used in the FDS experiment, ensuring that the up-conversion perturbation can be negligible is important. FDS was found to be a good technique for measuring the solvation dynamics of C153 in methanol. - Highlights: ► Mechanisms of subpicosecond fluorescence depletion spectroscopy. ► Quasi-continuous model was used to describe the solvational relaxation. ► The solvation dynamics of coumarin 153 in methanol has been measured.

  17. The Johnson Space Center Management Information Systems (JSCMIS). 1: Requirements Definition and Design Specifications for Versions 2.1 and 2.1.1. 2: Documented Test Scenario Environments. 3: Security Design and Specifications

    Science.gov (United States)

    1986-01-01

    The Johnson Space Center Management Information System (JSCMIS) is an interface to computer data bases at NASA Johnson which allows an authorized user to browse and retrieve information from a variety of sources with minimum effort. This issue gives requirements definition and design specifications for versions 2.1 and 2.1.1, along with documented test scenario environments, and security object design and specifications.

  18. Data for the screening assessment. Volume 1: Text, Columbia River Comprehensive Impact Assessment

    International Nuclear Information System (INIS)

    Miley, T.B.; O'Neil, T.K.; Gilbert, R.O.; Klevgard, L.A.; Walters, T.B.

    1996-06-01

    The Columbia River is a critical resource for residents of the Pacific Northwest. This resource drew the Manhattan Project's planners to the site now called Hanford to produce nuclear weapon materials. Production of those materials has left behind a legacy of chemical and radioactive contamination and materials that have, are, and will continue to pose a threat to the Columbia river for the foreseeable future. To evaluate the impact to the river from this Hanford-derived contamination, the US Department of Energy, US Environmental Protection Agency, and State of Washington Department of Ecology (the Tri-Party agencies) initiated a study referred to as the Columbia River Comprehensive Impact Assessment (CRCIA). To address concerns about the scope and direction of CRCIA as well as enhance regulator, stakeholder, tribal, and public involvement, the CRCIA Management Team was formed in August 1995. A major CRCIA Team decision was to organize CRCIA into phases, with additional phases to be identified as warranted after completion of the initial phase. The initial phase is comprised of two parts: (1) a screening assessment to evaluate the current impact to the river resulting from Hanford-derived contamination and (2) identification of requirements considered necessary by the CRCIA Management Team for a comprehensive assessment of impact to the river. The purpose of the screening assessment is to support cleanup decisions. The scope of the screening assessment is to evaluate the current risk to humans and the environment resulting from Hanford-derived contaminants. The screening assessment has the primary components of: identifying contaminants to be assessed; identifying a variety of exposure scenarios to evaluate human contaminant exposure; identifying a variety of other species to evaluate ecological contaminant exposure; and assessing risks posed by exposure of humans and other species to the contaminants

  19. Nuclear computerized library for assessing reactor reliability (NUCLARR): Data manual: Part 1, Summary description

    International Nuclear Information System (INIS)

    Gertman, D.I.; Gilbert, B.G.; Gilmore, W.E.; Galyean, W.J.

    1988-06-01

    This volume of a five-volume series summarizes those data currently resident in the first release of the Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR) data base. The raw human error probability (HEP) and hardware component failure data (HCFD) contained herein are accompanied by a glossary of terms and the HEP and hardware taxonomies used to structure the data. Instructions are presented on how the user may navigate through the NUCLARR data management system to find anchor values to assist in solving risk-related problems. Volume V: Data Manual will be updated on a periodic basis so that risk analysis without access to a computer may have access to the largest NUCLARR data. This document Part 1 of Volume 5 introduces aspects of the NUCLARR data base management system and prepares the reader for reviewing data in other Parts of Volume 5

  20. Long non-coding RNA PVT1: Emerging biomarker in digestive system cancer.

    Science.gov (United States)

    Zhou, Dan-Dan; Liu, Xiu-Fen; Lu, Cheng-Wei; Pant, Om Prakash; Liu, Xiao-Dong

    2017-12-01

    The digestive system cancers are leading cause of cancer-related death worldwide, and have high risks of morbidity and mortality. More and more long non-coding RNAs (lncRNAs) have been studied to be abnormally expressed in cancers and play a key role in the process of digestive system tumour progression. Plasmacytoma variant translocation 1 (PVT1) seems fairly novel. Since 1984, PVT1 was identified to be an activator of MYC in mice. Its role in human tumour initiation and progression has long been a subject of interest. The expression of PVT1 is elevated in digestive system cancers and correlates with poor prognosis. In this review, we illustrate the various functions of PVT1 during the different stages in the complex process of digestive system tumours (including oesophageal cancer, gastric cancer, colorectal cancer, hepatocellular carcinoma and pancreatic cancer). The growing evidence shows the involvement of PVT1 in both proliferation and differentiation process in addition to its involvement in epithelial to mesenchymal transition (EMT). These findings lead us to conclude that PVT1 promotes proliferation, survival, invasion, metastasis and drug resistance in digestive system cancer cells. We will also discuss PVT1's potential in diagnosis and treatment target of digestive system cancer. There was a great probability PVT1 could be a novel biomarker in screening tumours, prognosis biomarkers and future targeted therapy to improve the survival rate in cancer patients. © 2017 John Wiley & Sons Ltd.