WorldWideScience

Sample records for system postflight evaluation

  1. Post-Flight Back Pain Following International Space Station Missions: Evaluation of Spaceflight Risk Factors

    Science.gov (United States)

    Laughlin, M. S.; Murray, J. D.; Wear, M. L.; Van Baalen, M.

    2016-01-01

    INTRODUCTION Back pain during spaceflight has often been attributed to the lengthening of the spinal column due to the absence of gravity during both short and long-duration missions. Upon landing and re-adaptation to gravity, the spinal column reverts back to its original length thereby causing some individuals to experience pain and muscular spasms, while others experience no ill effects. With International Space Station (ISS) missions, cases of back pain and injury are more common post-flight, but little is known about the potential risk factors. Thus, the purpose of this project was to perform an initial evaluation of reported post-flight back pain and injury cases to relevant spaceflight risk factors in United States astronauts that have completed an ISS mission. METHODS All US astronauts who completed an ISS mission between Expeditions (EXP) 1 and 41 (2000-2015) were included in this evaluation. Forty-five astronauts (36 males and 9 females) completed 50 ISS missions during the study time period, as 5 astronauts completed 2 ISS missions. Researchers queried medical records of the 45 astronauts for occurrences of back pain and injury. A case was defined as any reported event of back pain or injury to the cervical, thoracic, lumbar, sacral, or coccyx spine regions. Data sources for the cases included the Flight Medicine Clinic's electronic medical record; Astronaut Strength, Conditioning and Rehabilitation electronic documentation; the Private Medical Conference tool; and the Space Medicine Operations Team records. Post-flight cases were classified as an early case if reported within 45 days of landing (R + 45) or a late case if reported from R + 46 to R + 365 days after landing (R + 1y). Risk factors in the astronaut population for back pain include age, sex, prior military service, and prior history of back pain. Additionally, spaceflight specific risk factors such as type of landing vehicle and onboard exercise countermeasures were included to evaluate their

  2. Post-Flight Evaluation of PICA and PICA-X - Comparisons of the Stardust SRC and Space-X Dragon 1 Forebody Heatshield Materials

    Science.gov (United States)

    Stackpoole, M.; Kao, D.; Qu, V.; Gonzales, G.

    2013-01-01

    Phenolic Impregnated Carbon Ablator (PICA) was developed at NASA Ames Research Center. As a thermal protection material, PICA has the advantages of being able to withstand high heat fluxes with a relatively low density. This ablative material was used as the forebody heat shield material for the Stardust sample return capsule, which re-entered the Earths atmosphere in 2006. Based on PICA, SpaceX developed a variant, PICA-X, and used it as the heat shield material for its Dragon spacecraft, which successfully orbited the Earth and re-entered the atmosphere during the COTS Demo Flight 1 in 2010. Post-flight analysis was previously performed on the Stardust PICA heat shield material. Similarly, a near-stagnation core was obtained from the post-flight Dragon 1 heat shield, which was retrieved from the Pacific Ocean. Materials testing and analyses were performed on the core to evaluate its ablation performance and post-flight properties. Comparisons between PICA and PICA-X are made where applicable. Stardust and Dragon offer rare opportunities to evaluate materials post-flight - this data is beneficial in understanding material performance and also improves modeling capabilities.

  3. Pre- and post-flight radiation performance evaluation of the space GPS receiver (SGR)

    International Nuclear Information System (INIS)

    Oldfield, M.K.; Underwood, C.I.; Unwin, M.J.; Asenek, V.; Harboe-Sorensen, R.

    1999-01-01

    SSTL (Survey Satellite Technology Ltd), in collaboration with ESA/ESTEC, recently developed a state-of-the-art low cost GPS (Global Positioning System) receiver payload for use on small satellites. The space GPS Receiver (SGR), will be flown on the TiungSAT-1 micro-satellite, UoSAT-12 mini-satellite and ESA's PROBA satellite. The SGR payload is currently flying on the TMSAT micro-satellite in low Earth orbit (LEO) and has carried out autonomous on-board positioning whilst also providing an experimental test-bed for evaluating spacecraft attitude determination algorithms. In order to reduce development time and costs, the SGR consists solely of industry standard COTS (commercial off-the-shelf) devices. This paper describes the ground-based radiation testing of several payload-critical COTS devices used in the SGR payload and describes its on-orbit performance. (authors)

  4. Post-Flight Microbial Analysis of Samples from the International Space Station Water Recovery System and Oxygen Generation System

    Science.gov (United States)

    Birmele, Michele N.

    2011-01-01

    The Regenerative, Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS) includes the the Water Recovery System (WRS) and the Oxygen Generation System (OGS). The WRS consists of a Urine Processor Assembly (UPA) and Water Processor Assembly (WPA). This report describes microbial characterization of wastewater and surface samples collected from the WRS and OGS subsystems, returned to KSC, JSC, and MSFC on consecutive shuttle flights (STS-129 and STS-130) in 2009-10. STS-129 returned two filters that contained fluid samples from the WPA Waste Tank Orbital Recovery Unit (ORU), one from the waste tank and the other from the ISS humidity condensate. Direct count by microscopic enumeration revealed 8.38 x 104 cells per mL in the humidity condensate sample, but none of those cells were recoverable on solid agar media. In contrast, 3.32 x lOs cells per mL were measured from a surface swab of the WRS waste tank, including viable bacteria and fungi recovered after S12 days of incubation on solid agar media. Based on rDNA sequencing and phenotypic characterization, a fungus recovered from the filter was determined to be Lecythophora mutabilis. The bacterial isolate was identified by rDNA sequence data to be Methylobacterium radiotolerans. Additional UPA subsystem samples were returned on STS-130 for analysis. Both liquid and solid samples were collected from the Russian urine container (EDV), Distillation Assembly (DA) and Recycle Filter Tank Assembly (RFTA) for post-flight analysis. The bacterium Pseudomonas aeruginosa and fungus Chaetomium brasiliense were isolated from the EDV samples. No viable bacteria or fungi were recovered from RFTA brine samples (N= 6), but multiple samples (N = 11) from the DA and RFTA were found to contain fungal and bacterial cells. Many recovered cells have been identified to genus by rDNA sequencing and carbon source utilization profiling (BiOLOG Gen III). The presence of viable bacteria and fungi from WRS

  5. Postflight analysis for Delta Program Mission no. 113: COS-B Mission

    Science.gov (United States)

    1976-01-01

    On 8 August 1975, the COS-B spacecraft was launched successfully from the Western Test Range (Delta Program Mission No. 113). The launch vehicle was a three stage Extended Long Tank Delta DSV-3P-11B vehicle. Postflight analyses performed in connection with flight are presented. Vehicle trajectory, stage performance, vehicle reliability and the propulsion, guidance, flight control, electronics, mechanical and structural systems are evaluated.

  6. Representation of the Physiological Factors Contributing to Postflight Changes in Functional Performance Using Motion Analysis Software

    Science.gov (United States)

    Parks, Kelsey

    2010-01-01

    Astronauts experience changes in multiple physiological systems due to exposure to the microgravity conditions of space flight. To understand how changes in physiological function influence functional performance, a testing procedure has been developed that evaluates both astronaut postflight functional performance and related physiological changes. Astronauts complete seven functional and physiological tests. The objective of this project is to use motion tracking and digitizing software to visually display the postflight decrement in the functional performance of the astronauts. The motion analysis software will be used to digitize astronaut data videos into stick figure videos to represent the astronauts as they perform the Functional Tasks Tests. This project will benefit NASA by allowing NASA scientists to present data of their neurological studies without revealing the identities of the astronauts.

  7. Pre- and post-flight radiation performance evaluation of the space GPS receiver (SGR); Evaluation de la tenue aux radiations, avant et apres lancement, du recepteur GPS spatial

    Energy Technology Data Exchange (ETDEWEB)

    Oldfield, M.K.; Underwood, C.I.; Unwin, M.J.; Asenek, V. [Surrey Univ., Surrey Space Centre, Guildford (United Kingdom); Harboe-Sorensen, R. [European Space Agency, ESA/ESTEC, Noordwijk (Netherlands)

    1999-07-01

    SSTL (Survey Satellite Technology Ltd), in collaboration with ESA/ESTEC, recently developed a state-of-the-art low cost GPS (Global Positioning System) receiver payload for use on small satellites. The space GPS Receiver (SGR), will be flown on the TiungSAT-1 micro-satellite, UoSAT-12 mini-satellite and ESA's PROBA satellite. The SGR payload is currently flying on the TMSAT micro-satellite in low Earth orbit (LEO) and has carried out autonomous on-board positioning whilst also providing an experimental test-bed for evaluating spacecraft attitude determination algorithms. In order to reduce development time and costs, the SGR consists solely of industry standard COTS (commercial off-the-shelf) devices. This paper describes the ground-based radiation testing of several payload-critical COTS devices used in the SGR payload and describes its on-orbit performance. (authors)

  8. Physiological Factors Contributing to Postflight Changes in Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Feedback, D. L.; Feiverson, A. H.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; Reschke, M. F.; Ryder, J.; Spiering, B. A.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objectives of the FTT are to: Develop a set of functional tasks that represent critical mission tasks for Constellation. Determine the ability to perform these tasks after flight. Identify the key physiological factors that contribute to functional decrements. Use this information to develop targeted countermeasures. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers will perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data will be collected on R+0 (Shuttle only), R

  9. Defining the Physiological Factors that Contribute to Postflight Changes in Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Arzeno, N.; Buxton, R.; Feiveson, A. H.; Kofman, I.; Lawrence, E.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objective of the FTT is to identify the key underlying physiological factors that contribute to performance of functional tests that are representative of critical mission tasks. This study will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor

  10. Evaluation of Galvanic Vestibular Stimulation System

    Science.gov (United States)

    Kofman, I. S.; Warren, E.; DeSoto, R.; Moroney, G.; Chastain, J.; De Dios, Y. E.; Gadd, N.; Taylor, L.; Peters, B. T.; Allen, E.; hide

    2017-01-01

    ) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

  11. Walk on Floor Eyes Closed Test as a Measure of Postflight Ataxia

    Science.gov (United States)

    Reschke, M. F.; Fisher, E. A.; Kofman, I. S.; Cerisano, J. M.; Harm, D.L.; Peters, B. T.; Bloomberg, J. J.

    2010-01-01

    INTRODUCTION: Astronauts returning from space flight universally exhibit impaired posture and locomotion. Measurement of this impairment is an evolving process. The walk on the floor line test with the eyes closed (WOFEC) provides a unique procedure for quantifying postflight ataxia. Data from a modified WOFEC were obtained as part of an ongoing NASA interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate astronaut postflight functional performance. METHODS: Seven astronauts (5 short duration with flights of 12-16 days; 2 long duration crewmembers with flights of 6 months) were tested twice before flight, on landing day (short duration only), and 1, 6, and 30 days after flight. The WOFEC consisted of walking for 10 steps (repeated twice) with the feet heel to toe in tandem, arms folded across the chest and the eyes closed. The performance metric (scored by three examiners from video) was the percentage of correct steps completed over the three trials. A step was not counted as correct if the crewmember sidestepped, opened their eyes, or paused for more than three seconds between steps. RESULTS/ CONCLUSIONS: There was a significant decrease in percentage of correct steps on landing day (short duration crew) and on first day following landing (long duration) with partial recovery the following day, and full recovery beginning on day sixth after flight. Both short and long duration fliers appeared to be unaware of foot position relative to their bodies or the floor. Postflight, deviation from a straight path was common, and the test for two crewmembers elicited motion sickness symptoms. These data clearly demonstrate the sensorimotor challenges facing crewmembers after returning from spaceflight. The WOFEC test has value providing the investigator or crew surgeon with a simple method to quantify vestibular ataxia, as well as providing instant feedback of postural ataxia without the use of complex test equipment.

  12. Orion Exploration Flight Test Post-Flight Inspection and Analysis

    Science.gov (United States)

    Miller, J. E.; Berger, E. L.; Bohl, W. E.; Christiansen, E. L.; Davis, B. A.; Deighton, K. D.; Enriquez, P. A.; Garcia, M. A.; Hyde, J. L.; Oliveras, O. M.

    2017-01-01

    The principal mechanism for developing orbital debris environment models, is to make observations of larger pieces of debris in the range of several centimeters and greater using radar and optical techniques. For particles that are smaller than this threshold, breakup and migration models of particles to returned surfaces in lower orbit are relied upon to quantify the flux. This reliance on models to derive spatial densities of particles that are of critical importance to spacecraft make the unique nature of the EFT-1's return surface a valuable metric. To this end detailed post-flight inspections have been performed of the returned EFT-1 backshell, and the inspections identified six candidate impact sites that were not present during the pre-flight inspections. This paper describes the post-flight analysis efforts to characterize the EFT-1 mission craters. This effort included ground based testing to understand small particle impact craters in the thermal protection material, the pre- and post-flight inspection, the crater analysis using optical, X-ray computed tomography (CT) and scanning electron microscope (SEM) techniques, and numerical simulations.

  13. Evaluation of the electromechanical properties of the cardiovascular system

    Science.gov (United States)

    Bergman, S. A., Jr.; Hoffler, G. W.; Johnson, R. L.

    1974-01-01

    Cardiovascular electromechanical measurements were collected on returning Skylab crewmembers at rest and during both lower body negative pressure and exercise stress testing. These data were compared with averaged responses from multiple preflight tests. Systolic time intervals and first heart sound amplitude changes were measured. Clinical cardiovascular examinations and clinical phonocardiograms were evaluated. All changes noted returned to normal within 30 days postflight so that the processes appear to be transient and self limited. The cardiovascular system seems to adapt quite readily to zero-g, and more importantly it is capable of readaptation to one-g after long duration space flight. Repeated exposures to zero-g also appear to have no detrimental effects on the cardiovascular system.

  14. Evaluation Use in Evaluation Systems

    DEFF Research Database (Denmark)

    Højlund, Steven

    2014-01-01

    This article investigates the European Union’s evaluation system and its conduciveness to evaluation use. Taking the European Commission’s LIFE programme as its case, the article makes an empirical contribution to an emerging focus in the literature on the importance of organization...... and institutions when analyzing evaluation use. By focusing on the European Union’s evaluation system the article finds that evaluation use mainly takes place in the European Commission and less so in the European Parliament and the European Council. The main explanatory factors enabling evaluation use relate...... to the system’s formalization of evaluation implementation and use; these factors ensure evaluation quality, timeliness and capacity in the Commission. At the same time, however, the system’s formalization also impedes evaluation use, reducing the direct influence of evaluations on policy-making and effectively...

  15. The Effects of Long-Duration Spaceflight on Postflight Terrestrial Locomotion

    Science.gov (United States)

    Bloomberg, J. J.; Mulavara, A. P.; McDonald, P. V.; Layne, C. S.; Merkle, L. A.; Cohen, H. S.; Kozlovskaya, I. B.

    1999-01-01

    Locomotion is a complex task requiring the coordinated integration of multiple sensorimotor subsystems. This coordination is exemplified by the precise control of segmental kinematics that allows smooth progression of movement in the face of changing environmental constraints. Exposure to the microgravity environment encountered during space flight induces adaptive modification in the central processing of sensory input to produce motor responses appropriate for the prevailing environment. This inflight adaptive change in sensorimotor function is inappropriate for movement control in 1-g and leads to postflight disturbances in terrestrial locomotor function. We have previously explored the effects of short-duration (7-16 days) space flight on the control of locomotion. The goal of the present set of studies was to investigate the effects of long-duration spaceflight (3-6 months) on the control of locomotion with particular emphasis on understanding how the multiple interacting systems are adaptively modified by prolonged microgravity exposure.

  16. Orion Exploration Flight Test-1 Post-Flight Navigation Performance Assessment Relative to the Best Estimated Trajectory

    Science.gov (United States)

    Gay, Robert S.; Holt, Greg N.; Zanetti, Renato

    2016-01-01

    This paper details the post-flight navigation performance assessment of the Orion Exploration Flight Test-1 (EFT-1). Results of each flight phase are presented: Ground Align, Ascent, Orbit, and Entry Descent and Landing. This study examines the on-board Kalman Filter uncertainty along with state deviations relative to the Best Estimated Trajectory (BET). Overall the results show that the Orion Navigation System performed as well or better than expected. Specifically, the Global Positioning System (GPS) measurement availability was significantly better than anticipated at high altitudes. In addition, attitude estimation via processing GPS measurements along with Inertial Measurement Unit (IMU) data performed very well and maintained good attitude throughout the mission.

  17. Nearshore Survey System Evaluation

    Science.gov (United States)

    2017-12-01

    ER D C/ CH L TR -1 7- 19 Coastal Field Data Collection Program Nearshore Survey System Evaluation Co as ta l a nd H yd ra ul ic s La...Collection Program ERDC/CHL TR-17-19 December 2017 Nearshore Survey System Evaluation Michael F. Forte, William A. Birkemeier, and J. Robert Mitchell...No. 462585 ERDC/CHL TR-17-19 ii Abstract This report evaluates the accuracy of two systems for surveying the beach and nearshore zone. The 10

  18. The OTOLITH Experiment - Assessment of Otolith Function During Postflight Re-adaption

    Science.gov (United States)

    Clarke, A. H.; Wood, S. J.; Schoenfeld, U.

    2010-01-01

    The ongoing "Otolith" experiment is designed to comprehensively assess the otolith function during the re-adaptation phase after spaceflight. The novel protocol includes unilateral testing of each of the two otolith organs the utricle and the saccule. To assess utricle function, the otolith-ocular response (OOR) and the subjective visual vertical (SVV) are measured during unilateral centrifugation, which permits independent stimulation of the right and left ear. Measurement of the unilateral otolith-ocular response (uOOR) yields information on the response behaviour of the right and left peripheral utricles, whereas the SVV reflects the behaviour of the entire pathway from the peripheral otolith receptors to the vestibular cortex. Thus, by comparative evaluation of the results from the two tests, the degree of peripheral versus central adaptation during the post-flight period can be determined. To assess unilateral saccule function, vestibular evoked myogenic potentials (VEMP) are recorded. Since the saccules are predominantly aligned to gravity, and interplay with the antigravity muscles, it is hypothesised that these potentials shall be altered after spaceflight. To date the study has been conducted with 5 of a planned 8 short-flight Shuttle astronauts. Preliminary results will be discussed together with those from clinical studies of dizziness patients, where the same test protocol is employed. ACKNOWLEDGEMENT This work is supported by the German Aerospace Center (Grant DLR W130729) and is conducted under the auspices of ESA, in cooperation with NASA.

  19. MODULAR CONSTRUCTION SYSTEM EVALUATION

    International Nuclear Information System (INIS)

    Gillespie, S.

    2002-01-01

    The purpose of this study is to respond to U.S. Department of Energy (DOE) Technical Direction Letter (TDL) 02-003 (Waisley 2001), which directs Bechtel SAIC Company, LLC (BSC) to complete a design study to recommend repository design options to support receipt and/or emplacement of any or all of the following: commercial spent nuclear fuel (CSNF), high-level radioactive waste (HLW), DOE-managed spent nuclear fuel (DSNF) (including naval spent nuclear fuel [SNF]), and immobilized plutonium (if available), as soon as practicable, but no later than 2010. From the possible design options, a recommended approach will be determined for further evaluation to support the preliminary design of the repository. This study integrates the results of the repository Design Evolution Study (Rowe 2002) with supporting studies concerning national transportation options (BSC 2002b) and Nevada transportation options (Gehner 2002). The repository Design Evolution Study documents the processes used to reevaluate the design, construction, operation, and cost of the repository in response to TDL 02-003 (Waisley 2001), and to determine possible repository conceptual design options. The transportation studies evaluate the national and Nevada transportation options that support the repository conceptual design options. An evaluation methodology was established, based on Program-level requirements developed for the study in reference BSC 2001a, to allow the repository and system design options to be evaluated on a consistent basis. The transportation options and the design components were integrated into system design implementation options, which were evaluated using receipt and emplacement scenarios. The scenarios tested the ability of the design concept to adapt to changes in funding, waste receipt rate, and Nevada rail transportation availability. The results of the evaluation (in terms of system throughput, cost, and schedule) were then compared to the Program-level requirements, and

  20. Process evaluation distributed system

    Science.gov (United States)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  1. Nuclear data evaluation method and evaluation system

    International Nuclear Information System (INIS)

    Liu Tingjin

    1995-01-01

    The evaluation methods and Nuclear Data Evaluation System have been developed in China. A new version of the system has been established on Micro-VAX2 computer, which is supported by IAEA under the technology assistance program. The flow chart of Chinese Nuclear Data Evaluation System is shown out. For last ten years, the main efforts have been put on the double differential cross section, covariance data and evaluated data library validation. The developed evaluation method and Chinese Nuclear Data Evaluation System have been widely used at CNDC and in Chinese Nuclear Data Network for CENDL. (1 tab., 15 figs.)

  2. Flight feeding systems design and evaluation. Supplement 1: Production guides. [for the Apollo food system

    Science.gov (United States)

    1973-01-01

    The requirements for processing, packaging, testing, and shipment of foods selected for use in the Apollo food system are presented. Specific foodstuffs chosen from the following categories are discussed: (1) soups; (2) juices; (3) breads; (4) meat and poultry products; (5) fruits and nuts; (6) desserts; and (7) beverages. Food procurement for the mobile quarantine facility and for Apollo preflight and postflight activities is also discussed.

  3. Human Performance Evaluation System

    International Nuclear Information System (INIS)

    Hardwick, R.J. Jr.

    1985-01-01

    Operating nuclear power plants requires high standards of performance, extensive training and responsive management. Despite our best efforts inappropriate human actions do occur, but they can be managed. An extensive review of License Event Reports (LERs) was conducted which indicated continual inadequacy in human performance and in evaluation of root causes. Of some 31,000 LERs, about 5,000 or 16% were directly attributable to inappropriate actions. A recent analysis of 87 Significant Event Reports (issued by INPO in 1983) identified inappropriate actions as being the most frequent root cause (44% of the total). A more recent analysis of SERs issued in 1983 and 1984 indicate that 52% of the root causes were attributed to human performance. The Human Performance Evaluation System (HPES) is a comprehensive, coordinated utility/industry system for evaluating and reporting human performance situtations. HPES is a result of the realization that current reporting system provide limited treatment of human performance and rarely provide adequate information about root causes of inappropriate actions by individuals. The HPES was implemented to identify and eliminate root causes of inappropriate actions

  4. Safety significance evaluation system

    International Nuclear Information System (INIS)

    Lew, B.S.; Yee, D.; Brewer, W.K.; Quattro, P.J.; Kirby, K.D.

    1991-01-01

    This paper reports that the Pacific Gas and Electric Company (PG and E), in cooperation with ABZ, Incorporated and Science Applications International Corporation (SAIC), investigated the use of artificial intelligence-based programming techniques to assist utility personnel in regulatory compliance problems. The result of this investigation is that artificial intelligence-based programming techniques can successfully be applied to this problem. To demonstrate this, a general methodology was developed and several prototype systems based on this methodology were developed. The prototypes address U.S. Nuclear Regulatory Commission (NRC) event reportability requirements, technical specification compliance based on plant equipment status, and quality assurance assistance. This collection of prototype modules is named the safety significance evaluation system

  5. Pervious Pavement System Evaluation

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, grade...

  6. Evaluation Systems, Ethics, and Development Evaluation

    Science.gov (United States)

    Thomas, Vinod

    2010-01-01

    After some 65 years of international development assistance, it is still difficult to show the effectiveness of aid in ways that are fully convincing. In part, this reflects inadequacies in the evaluation systems of the bilateral, multilateral, and global organizations that provide official development aid. Underlying these weaknesses often are a…

  7. MTA Computer Based Evaluation System.

    Science.gov (United States)

    Brenner, Lisa P.; And Others

    The MTA PLATO-based evaluation system, which has been implemented by a consortium of schools of medical technology, is designed to be general-purpose, modular, data-driven, and interactive, and to accommodate other national and local item banks. The system provides a comprehensive interactive item-banking system in conjunction with online student…

  8. Back pain in space and post-flight spine injury: Mechanisms and countermeasure development

    Science.gov (United States)

    Sayson, Jojo V.; Lotz, Jeffrey; Parazynski, Scott; Hargens, Alan R.

    2013-05-01

    During spaceflight many astronauts experience moderate to severe lumbar pain and deconditioning of paraspinal muscles. There is also a significant incidence of herniated nucleus pulposus (HNP) in astronauts post-flight being most prevalent in cervical discs. Relief of in-flight lumbar back pain is facilitated by assuming a knee-to-chest position. The pathogenesis of lumbar back pain during spaceflight is most likely discogenic and somatic referred (from the sinuvertebral nerves) due to supra-physiologic swelling of the lumbar intervertebral discs (IVDs) due to removal of gravitational compressive loads in microgravity. The knee-to-chest position may reduce lumbar back pain by redistributing stresses through compressive loading to the IVDs, possibly reducing disc volume by fluid outflow across IVD endplates. IVD stress redistribution may reduce Type IV mechanoreceptor nerve impulse propagation in the annulus fibrosus and vertebral endplate resulting in centrally mediated pain inhibition during spinal flexion. Countermeasures for lumbar back pain may include in-flight use of: (1) an axial compression harness to prevent excessive IVD expansion and spinal column elongation; (2) the use of an adjustable pulley exercise developed to prevent atrophy of spine muscle stabilisers; and (3) other exercises that provide Earth-like annular stress with low-load repetitive active spine rotation movements. The overall objective of these countermeasures is to promote IVD health and to prevent degenerative changes that may lead to HNPs post-flight. In response to "NASA's Critical Path Roadmap Risks and Questions" regarding disc injury and higher incidence of HNPs after space flight (Integrated Research Plan Gap-B4), future studies will incorporate pre- and post-flight imaging of International Space Station long-duration crew members to investigate mechanisms of lumbar back pain as well as degeneration and damage to spinal structures. Quantitative results on morphological, biochemical

  9. Control Evaluation Information System Savings

    Directory of Open Access Journals (Sweden)

    Eddy Sutedjo

    2011-05-01

    Full Text Available The purpose of this research is to evaluate the control of information system savings in the banking and to identify the weaknesses and problem happened in those saving systems. Research method used are book studies by collecting data and information needed and field studies by interview, observation, questioner, and checklist using COBIT method as a standard to assess the information system control of the company. The expected result about the evaluation result that show in the problem happened and recommendation given as the evaluation report and to give a view about the control done by the company. Conclusion took from this research that this banking company has met standards although some weaknesses still exists in the system.Index Terms - Control Information System, Savings

  10. Post-Flight Test Results of Acousto-Optic Modulator Devices Subjected to Space Exposure

    Science.gov (United States)

    Prasad, Narasimha S.; Trivedi, Sudhir; Rosemeier, Jolanta; Diestler, Mark

    2014-01-01

    The objective of the Materials International Space Station Experiment (MISSE) is to study the performance of novel materials when subjected to the synergistic effects of the harsh space environment for several months. MISSE missions provide an opportunity for developing space qualifiable materials. Several laser and lidar components were sent by NASA Langley Research Center (LaRC) as a part of the MISSE 7 mission. The MISSE 7 module was transported to the international space station (ISS) via STS 129 mission that was launched on Nov 16, 2009. Later, the MISSE 7 module was brought back to the earth via the STS 134 that landed on June 1, 2011. The MISSE 7 module that was subjected to exposure in a space environment for more than one and a half years included fiber laser, solid-state laser gain materials, detectors, and semiconductor laser diode. Performance testing of these components is now progressing. In this paper, the results of performance testing of a laser diode module sent by NASA Langley Research Center on MISSE 7 mission will be discussed. This paper will present the comparison of pre-flight and post-flight performance of two different COTS acousto-optic modulator (AOM) devices. Post-flight measurements indicate that these two devices did not undergo any significant performance degradation.

  11. "System evaluates system": method for evaluating the efficiency of IS

    Directory of Open Access Journals (Sweden)

    Dita Blazkova

    2016-10-01

    Full Text Available In paper I deal with the possible solution of evaluating the efficiency of information systems in companies. The large number of existing methods used to address the efficiency of information systems is dependent on the subjective responses of the user that may distort output evaluation. Therefore, I propose a method that eliminates the subjective opinion of a user as the primary data source. Applications, which I suggests as part of the method, collects relevant data. In this paper I describe the application in detail. This is a follow-on program on any system that runs parallel with it. The program automatically collects data for evaluation. Data include mainly time data, positions the mouse cursor, printScreens, i-grams of previous, etc. I propose a method of evaluation of the data, which identifies the degree of the friendliness of the information system to the user. Thus, the output of the method is the conclusion whether users, who work with the information system, can handle effectively work with it.

  12. Post-Flight Aerodynamic and Aerothermal Model Validation of a Supersonic Inflatable Aerodynamic Decelerator

    Science.gov (United States)

    Tang, Chun; Muppidi, Suman; Bose, Deepak; Van Norman, John W.; Tanimoto, Rebekah; Clark, Ian

    2015-01-01

    NASA's Low Density Supersonic Decelerator Program is developing new technologies that will enable the landing of heavier payloads in low density environments, such as Mars. A recent flight experiment conducted high above the Hawaiian Islands has demonstrated the performance of several decelerator technologies. In particular, the deployment of the Robotic class Supersonic Inflatable Aerodynamic Decelerator (SIAD-R) was highly successful, and valuable data were collected during the test flight. This paper outlines the Computational Fluid Dynamics (CFD) analysis used to estimate the aerodynamic and aerothermal characteristics of the SIAD-R. Pre-flight and post-flight predictions are compared with the flight data, and a very good agreement in aerodynamic force and moment coefficients is observed between the CFD solutions and the reconstructed flight data.

  13. Concurrent ultrasonic weld evaluation system

    Science.gov (United States)

    Hood, Donald W.; Johnson, John A.; Smartt, Herschel B.

    1987-01-01

    A system for concurrent, non-destructive evaluation of partially completed welds for use in conjunction with an automated welder. The system utilizes real time, automated ultrasonic inspection of a welding operation as the welds are being made by providing a transducer which follows a short distance behind the welding head. Reflected ultrasonic signals are analyzed utilizing computer based digital pattern recognition techniques to discriminate between good and flawed welds on a pass by pass basis. The system also distinguishes between types of weld flaws.

  14. Evaluating MT systems with BEER

    Directory of Open Access Journals (Sweden)

    Stanojević Miloš

    2015-10-01

    Full Text Available We present BEER, an open source implementation of a machine translation evaluation metric. BEER is a metric trained for high correlation with human ranking by using learning-to-rank training methods. For evaluation of lexical accuracy it uses sub-word units (character n-grams while for measuring word order it uses hierarchical representations based on PETs (permutation trees. During the last WMT metrics tasks, BEER has shown high correlation with human judgments both on the sentence and the corpus levels. In this paper we will show how BEER can be used for (i full evaluation of MT output, (ii isolated evaluation of word order and (iii tuning MT systems.

  15. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  16. Plant operator performance evaluation system

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Fukuda, Mitsuko; Kubota, Ryuji.

    1989-01-01

    A plant operator performance evaluation system to analyze plant operation records during accident training and to identify and classify operator errors has been developed for the purpose of supporting realization of a training and education system for plant operators. A knowledge engineering technique was applied to evaluation of operator behavior by both even-based and symptom-based procedures, in various situations including event transition due to multiple failures or operational errors. The system classifies the identified errors as to their single and double types based on Swain's error classification and the error levels reflecting Rasmussen's cognitive level, and it also evaluates the effect of errors on plant state and then classifies error influence, using 'knowledge for phenomena and operations', as represented by frames. It has additional functions for analysis of error statistics and knowledge acquisition support of 'knowledge for operations'. The system was applied to a training analysis for a scram event in a BWR plant, and its error analysis function was confirmed to be effective by operational experts. (author)

  17. Evaluation of the COGITO system

    DEFF Research Database (Denmark)

    Andersen, V.; Andersen, H.H.K.

    2002-01-01

    -site and for benefiting efficiently from the functionality of the site. In order to make the report a stand-alone report, it contains an introduction including 'Study of end-user needs and behaviour' exposing problemsconcerning e-commerce in general (taken from the D6.1), and a brief review of the objectives......This report covers the deliverable D7.2 of the COGITO project. It presents the evaluation of an 'intelligent' agent integrated into an e-commerce system. The aim of the agent is to support the user partly through direct communication and partly by guidinghim/her for navigating the web...... for the COGITO project in order to clarify the aims of the project. However, the important part of the report presents the methodology for evaluating theperformance of the COGITO agent and the outcome of this evaluation. The questionnaire for eliciting the background information for the test persons...

  18. Sympathetic nervous system and spaceflight

    Science.gov (United States)

    Cooke, William H.; Convertino, Victor A.

    2007-02-01

    Purpose: Orthostatic stability on Earth is maintained through sympathetic nerve activation sufficient to increase peripheral vascular resistance and defend against reductions of blood pressure. Orthostatic instability in astronauts upon return from space missions has been linked to blunted vascular resistance responses to standing, introducing the possibility that spaceflight alters normal function between sympathetic efferent traffic and vascular reactivity. Methods: We evaluated published results of spaceflight and relevant ground-based microgravity simulations in an effort to determine responses of the sympathetic nervous system and consequences for orthostatic stability. Results: Direct microneurographic recordings from humans in space revealed that sympathetic nerve activity is increased and preserved in the upright posture after return to Earth (STS-90). However, none of the astronauts studied during STS-90 presented with presyncope postflight, leaving unanswered the question of whether postflight orthostatic intolerance is associated with blunted sympathetic nerve responses or inadequate translation into vascular resistance. Conclusions: There is little evidence to support the concept that spaceflight induces fundamental sympathetic neuroplasticity. The available data seem to support the hypothesis that regardless of whether or not sympathetic traffic is altered during flight, astronauts return with reduced blood volumes and consequent heightened baseline sympathetic activity. Because of this, the ability to withstand an orthostatic challenge postflight is directly proportional to an astronaut's maximal sympathetic activation capacity and remaining sympathetic reserve.

  19. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the Seismic Module of the CARES system (Computer Analysis for Rapid Evaluation of Structures). This system was developed by Brookhaven National Laboratory (BNL) for the US Nuclear Regulatory Commission to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structured in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the Seismic Module in particular. The development of the Seismic Module of the CARES system is based on an approach which incorporates all major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities. It has been designed with user friendly features and it allows for interactive manipulation of various analysis phases during the seismic design process. The capabilities of the seismic module include (a) generation of artificial time histories compatible with given design ground response spectra, (b) development of Power Spectral Density (PSD) functions associated with the seismic input, (c) deconvolution analysis using vertically propagating shear waves through a given soil profile, and (d) development of in-structure response spectra or corresponding PSD's. It should be pointed out that these types of analyses can also be performed individually by using available computer codes such as FLUSH, SAP, etc. The uniqueness of the CARES, however, lies on its ability to perform all required phases of the seismic analysis in an integrated manner. 5 refs., 6 figs

  20. Management information systems software evaluation

    International Nuclear Information System (INIS)

    Al-Tunisi, N.; Ghazzawi, A.; Gruyaert, F.; Clarke, D.

    1995-01-01

    In November 1993, Saudi Aramco management endorsed a proposal to coordinate the development of the Management Information Systems (MISs) of four concurrent projects for its facilities Controls Modernization Program. The affected projects were the Ras Tanura Refinery Upgrade Project, the Abqaiq Plant Controls Modernization and the Shedgum and Uthmaniyah Gas plants Control Upgrade Projects. All of these projects had a significant requirement of MISs in their scope. Under the leadership of the Process and Control Systems Department, and MIS Coordination Team was formed with representatives of several departments. An MIS Applications Evaluation procedure was developed based on the Kepner Tregoe Decisions Analysis Process and general questionnaires were sent to over a hundred potential Vendors. The applications were divided into several categories, such as: Data Capture and Historization, Human User Interface, Trending, Reporting, Graphic Displays, Data Reconciliation, Statistical Analysis, Expert Systems, Maintenance Applications, Document Management and Operations Planning and Scheduling. For each of the MIS Application areas, detailed follow-up questionnaires were used to short list the candidate products. In May and June 1994, selected Vendors were invited to Saudi Arabia for an Exhibition which was open to all Saudi Aramco employees. In conjunction with this, the Vendors were subjected to a rigorous product testing exercise by independent teams of testers. The paper will describe the methods used and the lessons learned in this extensive software evaluation phase, which was a first for Saudi Aramco

  1. Management information systems software evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Tunisi, N.; Ghazzawi, A.; Gruyaert, F.; Clarke, D. [Saudi Aramco, Dhahran (Saudi Arabia). Process and Control Systems Dept.

    1995-11-01

    In November 1993, Saudi Aramco management endorsed a proposal to coordinate the development of the Management Information Systems (MISs) of four concurrent projects for its facilities Controls Modernization Program. The affected projects were the Ras Tanura Refinery Upgrade Project, the Abqaiq Plant Controls Modernization and the Shedgum and Uthmaniyah Gas plants Control Upgrade Projects. All of these projects had a significant requirement of MISs in their scope. Under the leadership of the Process and Control Systems Department, and MIS Coordination Team was formed with representatives of several departments. An MIS Applications Evaluation procedure was developed based on the Kepner Tregoe Decisions Analysis Process and general questionnaires were sent to over a hundred potential Vendors. The applications were divided into several categories, such as: Data Capture and Historization, Human User Interface, Trending, Reporting, Graphic Displays, Data Reconciliation, Statistical Analysis, Expert Systems, Maintenance Applications, Document Management and Operations Planning and Scheduling. For each of the MIS Application areas, detailed follow-up questionnaires were used to short list the candidate products. In May and June 1994, selected Vendors were invited to Saudi Arabia for an Exhibition which was open to all Saudi Aramco employees. In conjunction with this, the Vendors were subjected to a rigorous product testing exercise by independent teams of testers. The paper will describe the methods used and the lessons learned in this extensive software evaluation phase, which was a first for Saudi Aramco.

  2. Evaluating Storage Systems for Lustre

    Energy Technology Data Exchange (ETDEWEB)

    Oral, H. Sarp [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-08-20

    Storage systems are complex, including multiple subsystems and components. Sustained operations with top performance require all these subsystems and components working as expected. Having a detailed performance profile helps establishing a baseline. This baseline can be used for easier identification of possible future problems. A systematic bottom-to-top approach, starting with a detailed performance analysis of disks and moving up across layers and subsystems, provides a quantitative breakdown of each component's capabilities and bottlenecks. Coupling these low-level tests with Lustre-level evaluations will present a better understanding of performance expectations under different I/O workloads.

  3. Efficiency Evaluation of Energy Systems

    CERN Document Server

    Kanoğlu, Mehmet; Dinçer, İbrahim

    2012-01-01

    Efficiency is one of the most frequently used terms in thermodynamics, and it indicates how well an energy conversion or process is accomplished. Efficiency is also one of the most frequently misused terms in thermodynamics and is often a source of misunderstanding. This is because efficiency is often used without being properly defined first. This book intends to provide a comprehensive evaluation of various efficiencies used for energy transfer and conversion systems including steady-flow energy devices (turbines, compressors, pumps, nozzles, heat exchangers, etc.), various power plants, cogeneration plants, and refrigeration systems. The book will cover first-law (energy based) and second-law (exergy based) efficiencies and provide a comprehensive understanding of their implications. It will help minimize the widespread misuse of efficiencies among students and researchers in energy field by using an intuitive and unified approach for defining efficiencies. The book will be particularly useful for a clear ...

  4. Post-flight trajectory reconstruction of suborbital free-flyers using GPS raw data

    Science.gov (United States)

    Ivchenko, N.; Yuan, Y.; Linden, E.

    2017-08-01

    This paper describes the reconstruction of postflight trajectories of suborbital free flying units by using logged GPS raw data. We took the reconstruction as a global least squares optimization problem, using both the pseudo-range and Doppler observables, and solved it by using the trust-region-reflective algorithm, which enabled navigational solutions of high accuracy. The code tracking was implemented with a large number of correlators and least squares curve fitting, in order to improve the precision of the code start times, while a more conventional phased lock loop was used for Doppler tracking. We proposed a weighting scheme to account for fast signal strength variation due to free-flier fast rotation, and a penalty for jerk to achieve a smooth solution. We applied these methods to flight data of two suborbital free flying units launched on REXUS 12 sounding rocket, reconstructing the trajectory, receiver clock error and wind up rates. The trajectory exhibits a parabola with the apogee around 80 km, and the velocity profile shows the details of payloadwobbling. The wind up rates obtained match the measurements from onboard angular rate sensors.

  5. Post-Flight Characterization of Samples for the MISSE-7 Spacesuit Fabric Exposure Experiment

    Science.gov (United States)

    Gaier, James R.; Waters, Deborah L.; Jaworski, Donald A.; McCue, Terry R.; Folz, Angela; Baldwin, Sammantha; Clark, Gregory W.; Batman, Brittany; Bruce, John

    2012-01-01

    Six samples of pristine and dust-abraded outer layer spacesuit fabrics were included in the Materials International Space Station Experiment-7, in which they were exposed to the wake side low Earth orbit environment (LEO) on the International Space Station (ISS) for 18 months in order to determine whether abrasion by lunar dust increases radiation degradation. The fabric samples were characterized using optical microscopy, field emission scanning electron microscopy, and tensile testing before and after exposure on the ISS. Comparison of pre- and post-flight characterizations showed that wake side LEO environment darkened and reddened all six fabrics, increasing their integrated solar absorptance by 7 to 38 percent. There was a decrease in the ultimate tensile strength and elongation to failure of lunar dust abraded Apollo spacesuit fibers by a factor of four and increased the elastic modulus by a factor of two. The severity of the degradation of the fabric samples over this short exposure time demonstrates the necessity to find ways to prevent or mitigate radiation damage to spacesuits when planning extended missions to the Moon.

  6. Java Mission Evaluation Workstation System

    Science.gov (United States)

    Pettinger, Ross; Watlington, Tim; Ryley, Richard; Harbour, Jeff

    2006-01-01

    The Java Mission Evaluation Workstation System (JMEWS) is a collection of applications designed to retrieve, display, and analyze both real-time and recorded telemetry data. This software is currently being used by both the Space Shuttle Program (SSP) and the International Space Station (ISS) program. JMEWS was written in the Java programming language to satisfy the requirement of platform independence. An object-oriented design was used to satisfy additional requirements and to make the software easily extendable. By virtue of its platform independence, JMEWS can be used on the UNIX workstations in the Mission Control Center (MCC) and on office computers. JMEWS includes an interactive editor that allows users to easily develop displays that meet their specific needs. The displays can be developed and modified while viewing data. By simply selecting a data source, the user can view real-time, recorded, or test data.

  7. Altered Innate and Lymphocytic Immune Responses in Mouse Splenocytes Post-Flight

    Science.gov (United States)

    Hwang, ShenAn; Crucian, Brian E.; Sams, Clarence F.; Actor, Jeffrey K.

    2011-01-01

    Space flight is known to affect immune responses of astronauts and animals, decreasing lymphocytic responses to mitogenic stimuli, delayed typed hypersensitivity reactions, and T-cell activation. Despite changes in immune suppression, there are no reports of consistent adverse clinical events post flight. To further investigate the spectrum of affected immune responses, murine splenocytes were stimulated immediately post-shuttle flight (14 days on STS-135) with T-cell stimulators or toll-like receptor agonists. Comparisons were made to ground control splenocytes from age-matched mice. Cell phenotypes were assessed, as well as activation markers and associated cytokine production. The CD4+ population decreased with no concurrent decrease in CD8+ cells from shuttle mice post flight compared to ground controls. Regarding antigen presenting cell populations, the number of CD11c+ cells were slightly elevated post flight, compared to ground controls, with increased MHC Class I expression (I-A(sup b)) and no change in Class II expression (H-2K(sup b)). CD86+ populations were also significantly diminished. However, the decreased markers did not correlate with activity. Stimulation of splenocytes post flight showed significant increase in bead uptake, increased Class I expression, increased TNF-alpha and IL-6 production in response to TLR-2 (zymosan) and TLR-4 (LPS) agonists. While most activated (ConA or anti-CD3/anti-CD28) CD4+ cells showed markedly diminished responses (reduced IL-2 production), non-specific T cell responses to superantigen (SEA/SEB) increased post flight as determined by expression of early activation markers. Production of additional cytokines was also dysregulated postflight. Overall, persistent immune changes during space flight could represent unique clinical risks for exploration class missions. The consequences of pathogenic encounter remain an important concern that should be addressed.

  8. A MICROCOMPUTER MODEL FOR IRRIGATION SYSTEM EVALUATION

    OpenAIRE

    Williams, Jeffery R.; Buller, Orlan H.; Dvorak, Gary J.; Manges, Harry L.

    1988-01-01

    ICEASE (Irrigation Cost Estimator and System Evaluator) is a microcomputer model designed and developed to meet the need for conducting economic evaluation of adjustments to irrigation systems and management techniques to improve the use of irrigated water. ICEASE can calculate the annual operating costs for irrigation systems and has five options that can be used to economically evaluate improvements in the pumping plant or the way the irrigation system is used for crop production.

  9. Fission yield data evaluation system FYDES

    International Nuclear Information System (INIS)

    Liu Tingjin

    1998-01-01

    Taking account of some features of fission yield data, to do the fission yield data evaluation conveniently, a fission yield data evaluation system FYDES has been developed for last two years. Outline of the system, data retrieval and data table standardization, data correction codes, data averaging code, simultaneous evaluation code and data fit programs were introduced

  10. Failure Effects Evaluation for ATC Automation System

    Directory of Open Access Journals (Sweden)

    Rui Li

    2017-01-01

    Full Text Available ATC (air traffic control automation system is a complex system, which helps maintain the air traffic order, guarantee the flight interval, and prevent aircraft collision. It is essential to ensure the safety of air traffic. Failure effects evaluation is an important part of ATC automation system reliability engineering. The failure effects evaluation of ATC automation system is aimed at the effects of modules or components which affect the performance and functionality of the system. By analyzing and evaluating the failure modes and their causes and effects, some reasonable improvement measures and preventive maintenance plans can be established. In this paper, the failure effects evaluation framework considering performance and functionality of the system is established on the basis of reliability theory. Some algorithms for the quantitative evaluation of failure effects on performance of ATC automation system are proposed. According to the algorithms, the quantitative evaluation of reliability, availability, maintainability, and other assessment indicators can be calculated.

  11. Pervious Pavement System Evaluation- Abstract

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, gra...

  12. Evaluating safety management system implementation

    International Nuclear Information System (INIS)

    Preuss, M.

    2009-01-01

    Canada is committed to not only maintaining, but also improving upon our record of having one of the safest aviation systems in the world. The development, implementation and maintenance of safety management systems is a significant step towards improving safety performance. Canada is considered a world leader in this area and we are fully engaged in implementation. By integrating risk management systems and business practices, the aviation industry stands to gain better safety performance with less regulatory intervention. These are important steps towards improving safety and enhancing the public's confidence in the safety of Canada's aviation system. (author)

  13. Measurement and evaluation systems for NPP commissioning

    International Nuclear Information System (INIS)

    Elko, Marek

    2006-01-01

    Standard core monitoring and information systems are designed with an emphasis on normal operation of nuclear power plant. Their purpose is to provide necessary support for reactor operators and other operating personnel during the fuel cycle. After each fuel reloading, and to the larger extent during the plant commissioning, a variety of start-up tests need to be carried out and evaluated. Sampling periods, accuracy and communication delays of standard systems are not always suitable for test performance and evaluation. For technical and safety reasons, the access to standard monitoring and information systems is very limited. Non-Standard Measurement and Evaluation Systems are highly specialized devices designed with an emphasis on start-up tests performance and evaluation. They are capable of high frequency sampling, processing and communication of hundreds of technological signals with required accuracy and low communication delay. All technological signals needed for the test performance and evaluation are collected from various systems, concentrated in one system and fully accessible to a test leader, a reactor physicist or other users. In addition, Non-Standard Measurement and Evaluation Systems can perform other tasks like data storing and presentation, data distribution to other systems or external computers via network, reactivity calculations, etc. Structure of such systems can vary, but generally it is a mixture of two basic concepts: a mobile system and a stationary system. A basic description of hardware structure and software equipment of Non-Standard Measurement and Evaluation Systems is given in the paper (Authors)

  14. NEUROPHYSIOLOGICAL EVALUATION OF SENSORY SYSTEMS'

    Science.gov (United States)

    Exposure to many neurotoxic compounds has been shown to produce a sensory system dysfunction. Neurophysiological assessment of sensory function in humans and animal models often uses techniques known as sensory evoked potentials. Because both humans and animals show analogous res...

  15. Modular system design and evaluation

    CERN Document Server

    Levin, Mark Sh

    2015-01-01

    This book examines seven key combinatorial engineering frameworks (composite schemes consisting of algorithms and/or interactive procedures) for hierarchical modular (composite) systems. These frameworks are based on combinatorial optimization problems (e.g., knapsack problem, multiple choice problem, assignment problem, morphological clique problem), with the author’s version of morphological design approach – Hierarchical Morphological Multicritieria Design (HMMD) – providing a conceptual lens with which to elucidate the examples discussed. This approach is based on ordinal estimates of design alternatives for systems parts/components, however, the book also puts forward an original version of HMMD that is based on new interval multiset estimates for the design alternatives with special attention paid to the aggregation of modular solutions (system versions). The second part of ‘Modular System Design and Evaluation’ provides ten information technology case studies that enriches understanding of th...

  16. UNIX-based operating systems robustness evaluation

    Science.gov (United States)

    Chang, Yu-Ming

    1996-01-01

    Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.

  17. Overcoming barriers to evaluation of terminological systems

    NARCIS (Netherlands)

    Cornet, Ronald; de Keizer, Nicolette F.; Arts, Daniëlle G. T.

    2004-01-01

    Evaluation of terminological systems has been demonstrated to be a complicated task. This is due to the broad range of terminological systems, their application, and the clinical contexts in which they can be applied. We propose an evaluation framework that explicitly distinguishes an

  18. Task oriented evaluation system for maintenance robots

    International Nuclear Information System (INIS)

    Asame, Hajime; Endo, Isao; Kotosaka, Shin-ya; Takata, Shozo; Hiraoka, Hiroyuki; Kohda, Takehisa; Matsumoto, Akihiro; Yamagishi, Kiichiro.

    1994-01-01

    The adaptability evaluation of maintenance robots to autonomous plants has been discussed. In this paper, a new concept of autonomous plant with maintenance robots are introduced, and a framework of autonomous maintenance system is proposed. Then, task-oriented evaluation of robot arms is discussed for evaluating their adaptability to maintenance tasks, and a new criterion called operability is proposed for adaptability evaluation. The task-oriented evaluation system is implemented and applied to structural design of robot arms. Using genetic algorithm, an optimal structure adaptable to a pump disassembly task is obtained. (author)

  19. Development of a Sound Quality Evaluation System

    DEFF Research Database (Denmark)

    Kvist, Preben; Thomsen, Carsten; Lee, Sanjil

    2004-01-01

    This paper describes the development of the first version of the Sound Quality Evaluation System. The purpose of the system is to predict the subjective sound quality of home theater systems from objective measurements. 16 home theater systems were measured in an anechoic room. Several metrics...... expected to correlate w ith the subjective quality were proposed and tested. A model for the sound quality was created by mapping the subjective evaluations of the Home Theater System s with the metrics calculated for each system. Correlation between subjective listening test and the prediction is presente...

  20. How to Evaluate Integrated Library Automation Systems.

    Science.gov (United States)

    Powell, James R.; Slach, June E.

    1985-01-01

    This paper describes methodology used in compiling a list of candidate integrated library automation systems at a corporate technical library. Priorities for automation, identification of candidate systems, the filtering process, information for suppliers, software and hardware considerations, on-site evaluations, and final system selection are…

  1. Pervious Pavement System Evaluation-Poster

    Science.gov (United States)

    Pervious pavement is a low impact development stormwater control. The Environmental Protection Agency's Urban Watershed Management Branch is evaluating interlocking concrete pavingstone pervious pavement systems. The pavingstones themselves are impermeable, but the spaces between...

  2. IDEA: A Unifying Theory for Evaluation Systems

    DEFF Research Database (Denmark)

    Bella, Giampaolo; Giustolisi, Rosario

    2017-01-01

    and the type of evaluation. The uniformity of the security requirements across all groups offers additional validation, and this is an innovative finding in the direction, currently unexplored, of a common system design. Still, the requirements may variously shape up. For example, while voter privacy......Secure systems for voting, exams, auctions and conference paper management are theorised to address the same problem, that of secure evaluations. In support of such a unifying theory comes a model for Secure Evaluation Systems (SES), which offers innovative common grounds to understand all four...... groups. For example, all rest on submissions, respectively votes, test answers, bids and papers, which are to be evaluated and ultimately ranked. A taxonomy for all groups is advanced to provide a comparative understanding of the various systems. The taxonomy is built according to the type of submissions...

  3. Modeling a support system for the evaluator

    International Nuclear Information System (INIS)

    Lozano Lima, B.; Ilizastegui Perez, F; Barnet Izquierdo, B.

    1998-01-01

    This work gives evaluators a tool they can employ to give more soundness to their review of operational limits and conditions. The system will establish the most adequate method to carry out the evaluation, as well as to evaluate the basis for technical operational specifications. It also includes the attainment of alternative questions to be supplied to the operating entity to support it in decision-making activities

  4. Multimodal Trip Planner System final evaluation report.

    Science.gov (United States)

    2011-05-01

    This evaluation of the Multimodal Trip Planning System (MMTPS) is the culmination of a multi-year project evaluating the development and deployment of a multimodal trip planner in the Chicagoland area between 2004 and 2010. The report includes an ove...

  5. In-flight Assessment of Lower Body Negative Pressure as a Countermeasure for Post-flight Orthostatic Intolerance

    Science.gov (United States)

    Charles, J. B.; Stenger, M. B.; Phillips, T. R.; Arzeno, N. M.; Lee, S. M. C.

    2009-01-01

    Introduction. We investigated the efficacy of combining fluid loading with sustained lower body negative pressure (LBNP) to reverse orthostatic intolerance associated with weightlessness during and immediately after Space Shuttle missions. Methods. Shuttle astronauts (n=13) underwent 4 hours of LBNP at -30 mm(Hg) and ingested water and salt ( soak treatment) during flight in two complementary studies. In the first study (n=8), pre-flight heart rate (HR) and blood pressure (BP) responses to an LBNP ramp (5-min stages of -10 mm(Hg) steps to -50 mm(Hg) were compared to responses in-flight one and two days after LBNP soak treatment. In the second study (n=5), the soak was performed 24 hr before landing, and post-flight stand test results of soak subjects were compared with those of an untreated cohort (n=7). In both studies, the soak was scheduled late in the mission and was preceded by LBNP ramp tests at approximately 3-day intervals to document the in-flight loss of orthostatic tolerance. Results. Increased HR and decreased BP responses to LBNP were evident early in-flight. In-flight, one day after LBNP soak, HR and BP responses to LBNP were not different from pre-flight, but the effect was absent the second day after treatment. Post-flight there were no between-group differences in HR and BP responses to standing, but all 5 treatment subjects completed the 5-minute stand test whereas 2 of 7 untreated cohort subjects did not. Discussion. Exaggerated HR and BP responses to LBNP were evident within the first few days of space flight, extending results from Skylab. The combined LBNP and fluid ingestion countermeasure restored in-flight LBNP HR and BP responses to pre-flight levels and provided protection of post-landing orthostatic function. Unfortunately, any benefits of the combined countermeasure were offset by the complexity of its implementation, making it inappropriate for routine application during Shuttle flights.

  6. Comparison of three Land Evaluation Systems in Evaluating the ...

    African Journals Online (AJOL)

    Three land evaluation system.(Land Capability Classification, Fertility Capability Classification and Land Suitability Classification) were compared for their practical relevance in terms of the accuracy of their predictive value on seven major soil types in the humid forest zone of south western Nigeria. The result showed that ...

  7. Expected energy production evaluation for photovoltaic systems

    DEFF Research Database (Denmark)

    Ding, Yi; Østergaard, Jacob; Peng, Wang

    2011-01-01

    A photovoltaic (PV) system consists of many solar panels, which are connected in series, parallel or a combination of both. Energy production for the PV system with various configurations is different. In this paper, a methodology is developed to evaluate and analyze the expected energy production...

  8. Multidimensional evaluation on FR cycle systems

    International Nuclear Information System (INIS)

    Nakai, Ryodai; Fujii, Sumio; Takakuma, Katsuyuki; Katoh, Atsushi; Ono, Kiyoshi; Ohtaki, Akira; Shiotani, Hiroki

    2004-01-01

    This report explains some results of the multidimensional evaluation on various fast reactor cycle system concepts from an interim report of the 2nd phase of ''Feasibility Study on Commercialized FR Cycle System''. This method is designed to give more objective and more quantitative evaluations to clarify commercialized system candidate concepts. Here we brief current evaluation method from the five viewpoints of safety, economy, environment, resource and non-proliferation, with some trial evaluation results for some cycles consist of promising technologies in reactor, core and fuel, reprocessing and fuel manufacture. Moreover, we describe FR cycle deployment scenarios which describe advantages and disadvantages of the cycles from the viewpoints of uranium resource and radioactive waste based on long-term nuclear material mass flow analyses and advantages of the deployment of FR cycle itself from the viewpoints of the comparison with alternative power supplies as well as cost and benefit. (author)

  9. Evaluating Pension System Reform in Uruguay

    Directory of Open Access Journals (Sweden)

    Gonzalo Garmendia

    2010-01-01

    Full Text Available This article evaluates the reform to the system of pensions in Uruguay through these variables: coverage, fiscal impact, accumulation of funds, yield, and costs associated to the operation of the Administradoras de Fondos de Ahorro Previsional (AFAPS. The reform is evaluated positively, even though elements are identified, that must be considered in the future: to extend the reform to the rest of the system that was not included before, generate the correct structure to regulate and supervise the system, fit the age of retirement to accede to benefits, and offer alternatives for investments of the AFAPS.

  10. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  11. Evaluation of the MADAM waste measurement system

    International Nuclear Information System (INIS)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-01-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software

  12. Fuzzy comprehensive evaluation of district heating systems

    International Nuclear Information System (INIS)

    Wei Bing; Wang Songling; Li Li

    2010-01-01

    Selecting the optimal type of district heating (DH) system is of great importance because different heating systems have different levels of efficiency, which will impact the system economics, environment and energy use. In this study, seven DH systems were analysed and evaluated by the fuzzy comprehensive evaluation method. The dimensionless number-goodness was introduced into the calculation, the economics, environment and energy technology factors were considered synthetically, and the final goodness values were obtained. The results show that if only one of the economics, environment or energy technology factors are considered, different heating systems have different goodness values. When all three factors were taken into account, the final ranking of goodness values was: combined heating and power>gas-fired boiler>water-source heat pump>coal-fired boiler>ground-source heat pump>solar-energy heat pump>oil-fired boiler. The combined heating and power system is the best choice from all seven systems; the gas-fired boiler system is the best of the three boiler systems for heating purpose; and the water-source heat pump is the best of the three heat pump systems for heating and cooling.

  13. Automated Evaluation System for Human Pupillary Behavior.

    Science.gov (United States)

    Silva, Cleyton Rafael Gomes; Gonçalves, Cristhiane; Camilo, Eduardo N R; Boaretti Dos Santos, Fabio; Siqueira, Joyce; de Albuquerque, Eduardo Simões; de Melo Nunes Soares, Fabrízzio Alphonsus Alves; de Oliveira, Leandro Luís Galdino; da Costa, Ronaldo Martins

    2017-01-01

    Analyzing human pupillary behavior is a non-invasive method for evaluating neurological activity. This method contributes to the medical field because changes in pupillary behavior can be correlated with several health conditions such as Parkinson, Alzheimer, autism and diabetes. Analyzing human pupillary behavior is simple and low-cost, and may be used as a complementary diagnosis. Therefore, this work aims to develop an automated system to evaluate human pupillary behavior. The solution consists of a portable recording device, a pupillometer; integrated with a recording and evaluation software based on computer vision. The system is able to stimulate, record, measure and extract relevant features of human pupillary behavior. The results show that the proposed system is fast and accurate, and can be used as an assessment tool for real and extensive clinical practice and research.

  14. Preparing and evaluating delivery systems for proteins

    DEFF Research Database (Denmark)

    Jorgensen, L; Moeller, E H; van de Weert, M

    2006-01-01

    From a formulation perspective proteins are complex and therefore challenging molecules to develop drug delivery systems for. The success of a formulation depends on the ability of the protein to maintain the native structure and activity during preparation and delivery as well as during shipping...... and long-term storage of the formulation. Therefore, the development and evaluation of successful and promising drug delivery systems is essential. In the present review, some of the particulate drug delivery systems for parenteral delivery of protein are presented and discussed. The challenge...... for incorporation of protein in particulate delivery systems is exemplified by water-in-oil emulsions....

  15. Physical protection system design and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary`s capabilities, and range of adversary`s tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ``what to protect against whom.`` The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met.

  16. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ''what to protect against whom.'' The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met

  17. Mobile based optical form evaluation system

    Directory of Open Access Journals (Sweden)

    Asım Sinan YÜKSEL

    2016-05-01

    Full Text Available Optical forms that contain multiple-choice answers are widely used both for electing students and evaluating student achievements in education systems in our country and worldwide. Optical forms are evaluated by employing optical mark recognition techniques through optical readers. High cost of these machines, limited access to them, long waiting time for evaluation results make the process hard for educationists working in cities or countries. In this study, a mobile application was developed for the educationists who own mobile phones or tablets for the purpose of evaluating students' answer sheets quickly and independent of location and optical readers. Optical form recognition, reading and evaluation processes are done on the image of student's answer sheet that is taken with the mobile phone or tablet of educationist. The Android based mobile application that we developed has a user-friendly interface, high success rate and is the first of our knowledge application that operates on mobile platforms in this field.

  18. Evaluation of Explanation Interfaces in Recommender Systems

    Directory of Open Access Journals (Sweden)

    Sergio Cleger-Tamayo

    2017-05-01

    Full Text Available Explaining interfaces become a useful tool in systems that have a lot of content to evaluate by users. The different interfaces represent a help for the undecided users or those who consider systems as boxed black smart. These systems present recommendations to users based on different learning models. In this paper, we present the different objectives of the explanation interfaces and some of the criteria that you can evaluate, as well as a proposal of metrics to obtain results in the experiments. Finally, we showed the main results of a study with real users and their interaction with e-commerce systems. Among the main results, highlight the positive impact in relation to the time of interaction with the applications and acceptance of the recommendations received.

  19. CTBT integrated verification system evaluation model supplement

    Energy Technology Data Exchange (ETDEWEB)

    EDENBURN,MICHAEL W.; BUNTING,MARCUS; PAYNE JR.,ARTHUR C.; TROST,LAWRENCE C.

    2000-03-02

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0.

  20. CTBT integrated verification system evaluation model supplement

    International Nuclear Information System (INIS)

    EDENBURN, MICHAEL W.; BUNTING, MARCUS; PAYNE, ARTHUR C. JR.; TROST, LAWRENCE C.

    2000-01-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0

  1. Reliability evaluation of a natural circulation system

    International Nuclear Information System (INIS)

    Jafari, Jalil; D'Auria, Francesco; Kazeminejad, Hossein; Davilu, Hadi

    2003-01-01

    This paper discusses a reliability study performed with reference to a passive thermohydraulic natural circulation (NC) system, named TTL-1. A methodology based on probabilistic techniques has been applied with the main purpose to optimize the system design. The obtained results have been adopted to estimate the thermal-hydraulic reliability (TH-R) of the same system. A total of 29 relevant parameters (including nominal values and plausible ranges of variations) affecting the design and the NC performance of the TTL-1 loop are identified and a probability of occurrence is assigned for each value based on expert judgment. Following procedures established for the uncertainty evaluation of thermal-hydraulic system codes results, 137 system configurations have been selected and each configuration has been analyzed via the Relap5 best-estimate code. The reference system configuration and the failure criteria derived from the 'mission' of the passive system are adopted for the evaluation of the system TH-R. Four different definitions of a less-than-unity 'reliability-values' (where unity represents the maximum achievable reliability) are proposed for the performance of the selected passive system. This is normally considered fully reliable, i.e. reliability-value equal one, in typical Probabilistic Safety Assessment (PSA) applications in nuclear reactor safety. The two 'point' TH-R values for the considered NC system were found equal to 0.70 and 0.85, i.e. values comparable with the reliability of a pump installed in an 'equivalent' forced circulation (active) system having the same 'mission'. The design optimization study was completed by a regression analysis addressing the output of the 137 calculations: heat losses, undetected leakage, loop length, riser diameter, and equivalent diameter of the test section have been found as the most important parameters bringing to the optimal system design and affecting the TH-R. As added values for this work, the comparison has

  2. evaluation of municipal solid waste management system

    African Journals Online (AJOL)

    eobe

    This paper reports the evaluation of households' usage of the current solid waste management system (SWMS) within the city of Ilorin, central Nigeria and investigates the determi within the city of Ilorin, central Nigeria and investigates the determinants of household's willingness nants of household's willingness nants of ...

  3. Pervious Pavement System Evaluation-Paper

    Science.gov (United States)

    The use of a pervious pavement can be effective as a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete paver systems as a type of porous pavement. Although the pavers are impermeable, the spaces between the pave...

  4. Cedar Avenue driver assist system evaluation report.

    Science.gov (United States)

    2011-12-01

    This paper summarizes an evaluation of the Driver Assist System (DAS) used by the Minnesota Valley Transit Authority (MTVA) for bus shoulder operations. The DAS is a GPS-based technology suite that provides lane-position feedback to the driver via a ...

  5. Virginia power's human performance evaluation system (HPES)

    International Nuclear Information System (INIS)

    Patterson, W.E.

    1991-01-01

    This paper reports on the Human Performance Evaluation System (HPES) which was initially developed by the Institute of Nuclear Power Operations (INPO) using the Aviation Safety Reporting System (ASRS) as a guide. After a pilot program involving three utilities ended in 1983, the present day program was instituted. A methodology was developed, for specific application to nuclear power plant employees, to aid trained coordinators/evaluators in determining those factors that exert a negative influence on human behavior in the nuclear power plant environment. HPES is for anyone and everyone on site, from contractors to plant staff to plant management. No one is excluded from participation. Virginia Power's HPES program goal is to identify and correct the root causes of human performance problems. Evaluations are performed on reported real or perceived conditions that may have an adverse influence on members of the nuclear team. A report is provided to management identifying root cause and contributing factors along with recommended corrective actions

  6. Dorsal raphe nucleus of brain in the rats flown in space inflight and postflight alteration of structure

    Science.gov (United States)

    Krasnov, I.

    The structure of brain dorsal raphe nucleus (DRN) was studied in the rats flown in space aboard Space Shuttle "Columbia" (STS-58, SLS-2 program) and dissected on day 13 of the mission ("inflight" rats) and in 5-6 hours after finishing 14-day flight ("postflight" rats). The brain of "inflight" rats were excised after decapitation, sectioned sagitally halves of brain were fixed by immersion in 2,5 % glutaraldehyde in 0.1 M cacodylate buffer pH 7.3 at 4°C and kept in the flight at 4°C. After landing the brain frontal 0.5 mm sections from DRN area were osmificated and embedded in araldite at NASA ARC. The brains of "postflight": and control rats were underwent to the same procedure. Electronmicroscopical analysis, computer morphometry and glial cell count were performed at Moscow. In DRN neuropil of "inflight" rats the most part of axo-dendritic synapses were surrounded by glia cell processes and had decreased electron density of pre- and postsynaptic membrane and pronounced diminution of synaptic vesicle amount while dendrites were characterized by decrease in matrix electron density and microtubule quantity that in total indicates the decline of afferent flow reaching DRN neurons in microgravity. In DRN neurons of "inflight" rats all mitochondria were characterized by evenly increased dimensions, decreased matrix electron density, small amount of short and far- between located cristae and enlarged intermembrane and intercristae spaces, that in total points out low level of coupling of oxidation to phosphorilation, decrease in energy supply of neuron. Amount of ribosome in cytoplasm was significantly decreased indicating lower lever of biosynthetic processes. The last is supported by diminished dimensions of neuronal body, nucleus and nucleolus (place of r RNA synthesis), cross section area of that were reduced in DRN neurons of "inflight" rats by 18.8 % (p functional activity of DRN - main serotoniner gic center of brain and in combination with the data (Krasnov et

  7. Evaluating Evaluation Systems: Policy Levers and Strategies for Studying Implementation of Educator Evaluation. Policy Snapshot

    Science.gov (United States)

    Matlach, Lauren

    2015-01-01

    Evaluation studies can provide feedback on implementation, support continuous improvement, and increase understanding of evaluation systems' impact on teaching and learning. Despite the importance of educator evaluation studies, states often need support to prioritize and fund them. Successful studies require expertise, time, and a shared…

  8. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  9. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  10. Composite system reliability evaluation by stochastic calculation of system operation

    Energy Technology Data Exchange (ETDEWEB)

    Haubrick, H.-J.; Hinz, H.-J.; Landeck, E. [Dept. of Power Systems and Power Economics (Germany)

    1994-12-31

    This report describes a new developed probabilistic approach for steady-state composite system reliability evaluation and its exemplary application to a bulk power test system. The new computer program called PHOENIX takes into consideration transmission limitations, outages of lines and power stations and, as a central element, a highly sophisticated model to the dispatcher performing remedial actions after disturbances. The kernel of the new method is a procedure for optimal power flow calculation that has been specially adapted for the use in reliability evaluations under the above mentioned conditions. (author) 11 refs., 8 figs., 1 tab.

  11. Evaluation of a multiport groundwater monitoring system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Hall, S.H.; Olsen, K.B.; Spane, F.A. Jr.

    1991-03-01

    In 1988 and 1989, Pacific Northwest Laboratory installed a multiport groundwater monitoring system in two wells on the Hanford Site: one near the 216-B-3 Pond in the center of the Hanford Site and one just north of the 300 Area near the Columbia River. The system was installed to provide the US Department of Energy with needed three-dimensional data on the vertical distribution of contaminants and hydraulic heads on the Hanford Site. This study evaluates the ability of the multiport system to obtain hydrogeologic data at multiple points vertically in a single borehole, and addresses the representativeness of the data. Data collected from the two wells indicate that the multiport system is well suited for groundwater monitoring networks requiring three-dimensional characterization of the hydrogeologic system. A network of these systems could provide valuable information on the hydrogeologic environment. However, the advantages of the multiport system diminish when the system is applied to long-term monitoring networks (30+ years) and to deeper wells (<300 ft). For shallow wells, the multiport system provides data in a cost-effective manner that would not be reasonably obtainable with the conventional methods currently in use at the Hanford Site. 17 refs., 28 figs., 6 tabs

  12. Multi-purpose canister system evaluation: A systems engineering approach

    International Nuclear Information System (INIS)

    1994-09-01

    This report summarizes Department of Energy (DOE) efforts to investigate various container systems for handling, transporting, storing, and disposing of spent nuclear fuel (SNF) assemblies in the Civilian Radioactive Waste Management System (CRWMS). The primary goal of DOE's investigations was to select a container technology that could handle the vast majority of commercial SNF at a reasonable cost, while ensuring the safety of the public and protecting the environment. Several alternative cask and canister concepts were evaluated for SNF assembly packaging to determine the most suitable concept. Of these alternatives, the multi-purpose canister (MPC) system was determined to be the most suitable. Based on the results of these evaluations, the decision was made to proceed with design and certification of the MPC system. A decision to fabricate and deploy MPCs will be made after further studies and preparation of an environmental impact statement

  13. Evaluation of a prototype infrasound system

    International Nuclear Information System (INIS)

    Whitaker, R.; Sandoval, T.; Breding, D.; Kromer, D.

    1997-01-01

    Under Department of Energy sponsorship, Sandia National Laboratories and Los Alamos National Laboratory cooperated to develop a prototype infrasonic array, with associated documentation, that could be used as part of the International Monitoring System. The United States Government or foreign countries could procure commercially available systems based on this prototype to fulfill their Comprehensive Test Ban Treaty (CTBT) obligations. The prototype is a four-element array in a triangular layout as recommended in CD/NTB/WP.224 with an element at each corner and one in the center. The prototype test configuration utilize an array spacing of 1 km. The prototype infrasound system has the following objectives: (1) Provide a prototype that reliably acquires and transmits near real-time infrasonic data to facilitate the rapid location and identification of atmospheric events. (2) Provide documentation that could be used by the United States and foreign countries to procure infrasound systems commercially to fulfill their CTBT responsibilities. Infrasonic monitoring is an effective, low cost technology for detecting atmospheric explosions. The low frequency components of explosion signals propagate to long ranges (few thousand kilometers) where they can be detected with an array of sensors. Los Alamos National Laboratory's expertise in infrasound systems and phenomenology when combined with Sandia's expertise in providing verification quality system for treaty monitoring make an excellent team to provide the prototype infrasound sensor system. By September 1997, the prototype infrasound system will have been procured, integrated, evaluated and documented. Final documentation will include a system requirements document, an evaluation report and a hardware design document. The hardware design document will describe the various hardware components used in the infrasound prototype and their interrelationships

  14. Cochlear implants: system design, integration, and evaluation.

    Science.gov (United States)

    Zeng, Fan-Gang; Rebscher, Stephen; Harrison, William; Sun, Xiaoan; Feng, Haihong

    2008-01-01

    As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.

  15. Solar energy system economic evaluation: IBM System 2, Togus, Maine

    Science.gov (United States)

    1980-01-01

    The economic analysis of the solar energy system, is developed for Torgus and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f-chart design procedure with inputs taken on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over a projected twenty year life, life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results demonstrate that the solar energy system is economically viable at all of the five sites for which the analysis was conducted.

  16. Post-Flight Test Results of Seed Laser Module Subjected to Space Exposure. Paper No. 8876-9

    Science.gov (United States)

    Prasad, Narasimha S.

    2013-01-01

    The objective of the Materials International Space Station Experiment (MISSE) is to study the performance of novel materials when subjected to the synergistic effects of the harsh space environment for several months. MISSE missions provide an opportunity for developing space qualifiable materials. Several laser and lidar components were sent by NASA Langley Research Center (LaRC) as a part of the MISSE 7 mission. The MISSE 7 module was transported to the international space station (ISS) via STS 129 mission that was launched on Nov 16, 2009. Later, the MISSE 7 module was brought back to the earth via the STS 134 that landed on June 1, 2011. The MISSE 7 module that was subjected to exposure in space environment for more than one and a half year included fiber laser, solid-state laser gain materials, detectors, and semiconductor laser diode. Performance testing of these components is now progressing. In this paper, the results of performance testing of a laser diode module sent by NASA Langley Research Center on MISSE 7 mission will be discussed. This paper will present the comparison of pre-flight and post-flight performance curves and discuss the effect of space exposure on the laser diode module. Preliminary findings on output power measurements show that the COTS laser diode characteristics did not undergo any significant performance degradation.

  17. Post-Flight Analysis of Selected Fluorocarbon and Other Thin Film Polymer Specimens Flown on MISSE-5

    Science.gov (United States)

    DeGroh, Kim; Finckenor, Miria; Minton, Tim; Brunsvold, Amy; Pippin, Gary

    2007-01-01

    Twenty thin film specimens were flown on M1SSE-5 as a cooperative effort between several organizations. This presentation will report results of initial inspections and post-flight measurements of the optical properties and recession of these materials due to the approx.13 month exposure period on the exterior of the International Space Station. These specimens were located on the "anti-solar" side of the MISSE-5 container and received a low number of Equivalent Sun Hours of solar UV exposure. Profilometry and/or ATF measurements will be conducted to determine thickness changes and atomic oxygen-induced recession rates Six of the specimens were covered with thin Kapton films, 0.1 and 0.3 mil in thickness. The 0.1 mil Kapton was almost completely eroded, suggesting that the atomic oxygen fluence is <8 x 10(exp 19) atoms/sq cm, similar to levels experienced during Space Shuttle materials experiments in the 1980's and 1990's. A comparison of results from MISSE-5 and Space Shuttle experiments will be included for those materials common to both the short and long-term exposures.

  18. CTBT Integrated Verification System Evaluation Model

    Energy Technology Data Exchange (ETDEWEB)

    Edenburn, M.W.; Bunting, M.L.; Payne, A.C. Jr.

    1997-10-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia`s Monitoring Systems and Technology Center and has been funded by the US Department of Energy`s Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, top-level, modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM`s unique features is that it integrates results from the various CTBT sensor technologies (seismic, infrasound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection) and location accuracy of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system`s performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. This report describes version 1.2 of IVSEM.

  19. 14 CFR 437.53 - Pre-flight and post-flight operations.

    Science.gov (United States)

    2010-01-01

    ... operations and systems in preparing a reusable suborbital rocket for flight at a launch site in the United States and returning the reusable suborbital rocket and any support equipment to a safe condition after...

  20. Overview of Pre-Flight Physical Training, In-Flight Exercise Countermeasures and the Post-Flight Reconditioning Program for International Space Station Astronauts

    Science.gov (United States)

    Kerstman, Eric

    2011-01-01

    International Space Station (ISS) astronauts receive supervised physical training pre-flight, utilize exercise countermeasures in-flight, and participate in a structured reconditioning program post-flight. Despite recent advances in exercise hardware and prescribed exercise countermeasures, ISS crewmembers are still found to have variable levels of deconditioning post-flight. This presentation provides an overview of the astronaut medical certification requirements, pre-flight physical training, in-flight exercise countermeasures, and the post-flight reconditioning program. Astronauts must meet medical certification requirements on selection, annually, and prior to ISS missions. In addition, extensive physical fitness testing and standardized medical assessments are performed on long duration crewmembers pre-flight. Limited physical fitness assessments and medical examinations are performed in-flight to develop exercise countermeasure prescriptions, ensure that the crewmembers are physically capable of performing mission tasks, and monitor astronaut health. Upon mission completion, long duration astronauts must re-adapt to the 1 G environment, and be certified as fit to return to space flight training and active duty. A structured, supervised postflight reconditioning program has been developed to prevent injuries, facilitate re-adaptation to the 1 G environment, and subsequently return astronauts to training and space flight. The NASA reconditioning program is implemented by the Astronaut Strength, Conditioning, and Rehabilitation (ASCR) team and supervised by NASA flight surgeons. This program has evolved over the past 10 years of the International Space Station (ISS) program and has been successful in ensuring that long duration astronauts safely re-adapt to the 1 g environment and return to active duty. Lessons learned from this approach to managing deconditioning can be applied to terrestrial medicine and future exploration space flight missions.

  1. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.; Gurbuz, E.

    1993-03-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSCsuperconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  2. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.G.; Gurbuz, E.

    1994-01-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSC superconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  3. Comprehensive evaluation system of intelligent urban growth

    Science.gov (United States)

    Li, Lian-Yan; Ren, Xiao-Bin

    2017-06-01

    With the rapid urbanization of the world, urban planning has become increasingly important and necessary to ensure people have access to equitable and sustainable homes, resources and jobs.This article is to talk about building an intelligent city evaluation system.First,using System Analysis Model(SAM) which concludes literature data analysis and stepwise regression analysis to describe intelligent growth scientifically and obtain the evaluation index. Then,using the improved entropy method to obtain the weight of the evaluation index.Afterwards, establishing a complete Smart Growth Comprehensive Evaluation Model(SGCEM).Finally,testing the correctness of the model.Choosing Otago(New Zealand )and Yumen(China) as research object by data mining and SGCEM model,then we get Yumen and Otago’s rational degree’s values are 0.3485 and 0.5376 respectively. It’s believed that the Otago’s smart level is higher,and it is found that the estimated value of rationality is consistent with the reality.

  4. Decision support system for utility performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Anselin, L.; Henderson, J.S.

    1985-01-01

    In a previous NRRI report (Anselin, Pike, Smith (1981), ''The Measurement of Electric Utility Performance: Preliminary Analysis''), an overview of several traditional methodologies to achieve this was presented (management audits, financial and engineering indexes, econometric studies), and a new technique based on multicriteria decision analysis was suggested. In this report, the decision analytic method for performance evaluation is considered in more detail, and compared to the more traditional approaches of a total factor productivity index (TFP) and econometric cost function estimates. Utility performance evaluation is considered as part of a decision support system, i.e., the combination of an information system (data base) and a set of operational decision rules (performance indexes). As part of this decision support system, an extensive data on 210 variables for 123 privately owned electric utilities over the period 1964-1981. Multicriteria evaluation techniques, such as the analytic hierarchy process and concordance analysis, and economic techniques, such as a total factor productivity (TFP) index and the residual analysis of econometric short- and long-run cost functions are discussed in detail with respect to their methodological and theoretical foundations. They are also implemented empirically on a common data base, and compared with respect to the resulting performance rating of the companies. 78 references.

  5. Solar energy system economic evaluation: IBM System 4, Clinton, Mississippi

    Science.gov (United States)

    1980-01-01

    An economic analysis of the solar energy system was developed for five sites, typical of a wide range of environmental and economic conditions in the continental United States. The analysis was based on the technical and economic models in the F-chart design procedure, with inputs based on the characteristic of the installed system and local conditions. The results are of the economic parameters of present worth of system cost over a 20 year time span: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  6. TurboTech Technical Evaluation Automated System

    Science.gov (United States)

    Tiffany, Dorothy J.

    2009-01-01

    TurboTech software is a Web-based process that simplifies and semiautomates technical evaluation of NASA proposals for Contracting Officer's Technical Representatives (COTRs). At the time of this reporting, there have been no set standards or systems for training new COTRs in technical evaluations. This new process provides boilerplate text in response to interview style questions. This text is collected into a Microsoft Word document that can then be further edited to conform to specific cases. By providing technical language and a structured format, TurboTech allows the COTRs to concentrate more on the actual evaluation, and less on deciding what language would be most appropriate. Since the actual word choice is one of the more time-consuming parts of a COTRs job, this process should allow for an increase in quantity of proposals evaluated. TurboTech is applicable to composing technical evaluations of contractor proposals, task and delivery orders, change order modifications, requests for proposals, new work modifications, task assignments, as well as any changes to existing contracts.

  7. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  8. Ultrasonic nondestructive evaluation systems industrial application issues

    CERN Document Server

    Callegari, Sergio; Montisci, Augusto; Ricci, Marco; Versaci, Mario

    2015-01-01

    This book covers the practical implementation of ultrasonic NDT techniques in an industrial environment, discussing several issues that may emerge and proposing strategies for addressing them successfully.  It aims to bridge advanced academic research results and their application to industrial procedures. The topics covered in the text range from the basic operation of an ultrasonic NDT system to the simulation of the measurement operations; from the choice and generation of the signals energizing the system to the different ways of exploiting the probes and their output signals; and from quality assessment evaluation to the use of soft computing techniques for classification. Throughout the text, an effort is made to embrace a system view where the physical and technological aspects of sensing are addressed together with higher abstraction levels, such as signal and information processing. Consequently, the book aims at guiding the reader through the various tasks requested for developing a complete ultras...

  9. Evaluating Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Arena, L.

    2013-02-01

    During the course of this project, an affordable and high performance ductwork system to directly address the problems of thermal losses, poor efficiency, and air leakage was designed. To save space and enable direct connections between different floors of the building, the ductwork system was designed in such a way that it occupied interior or exterior frame wall cavities. The ductwork system satisfied building regulations for structural support when bridging multiple floors, the spread of fire and smoke, and insulation to reduce the heat flow into or out of the building. Retrofits of urban residential buildings will be the main focus for the application of this ductwork system. Highly reflective foils and insulating materials were used to aid in the increase of the overall R-value of the ductwork itself and the wall assembly. It is expected that the proposed system will increase the efficiency of the HVAC system and the thermal resistance of the building envelope. The performance of the proposed ductwork design was numerically evaluated in a number of different ways. Our results indicate that the duct method is a very cost attractive alternative to the conventional method.

  10. Evaluation of PEGIT duct connection system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Brenner, Douglas E.; Sherman, Max H.; Dickerhoff, Darryl J.

    2003-08-01

    Most air duct system components are assembled in the field and are mechanically fastened by sheet metal screws (for sheet metal-to-sheet metal) or by drawbands (for flex duct-to-sheet metal). Air sealing is separate from this mechanical fastening and is usually achieved using tape or mastic products after mechanical fastening. Field observations have shown that mechanical fastening rarely meets code or manufacturers requirements and that sealing procedures are similarly inconsistent. To address these problems, Proctor Engineering Group (PEG) is developing a system of joining ducts (called PEGIT) that combines the mechanical fastening and sealing into a single self-contained procedure. The PEGIT system uses a shaped flexible seal between specially designed sheet metal duct fittings to both seal and fasten duct sections together. Figure 1 shows the inner duct fitting complete with rubber seal. This seal provides the air seal for the completed fitting and is shaped to allow the inner and outer fittings to slide together, and then to lock the fittings in place. The illustration in Figure 2 shows the approximate cross section of the rubber seal that shows how the seal has a lip that is angled backwards. This angled lip allows the joint to be pushed together by folding flat but then its long axis makes it stiff in the pulling apart direction. This study was undertaken to assist PEG in some of the design aspects of this system and to test the performance of the PEGIT system. This study was carried out in three phases. The initial phase evaluated the performance of a preliminary seal design for the PEGIT system. After the first phase, the seal was redesigned and this new seal was evaluated in the second phase of testing. The third phase performed more detailed testing of the second seal design to optimize the production tolerances of the sheet metal fittings. This report summarizes our findings from the first two phases and provides details about the third phase of testing.

  11. Evaluation of Nuclear Hydrogen Production System

    International Nuclear Information System (INIS)

    Park, Won Seok; Park, C. K.; Park, J. K. and others

    2006-04-01

    The major objective of this work is tow-fold: one is to develop a methodology to determine the best VHTR types for the nuclear hydrogen demonstration project and the other is to evaluate the various hydrogen production methods in terms of the technical feasibility and the effectiveness for the optimization of the nuclear hydrogen system. Both top-tier requirements and design requirements have been defined for the nuclear hydrogen system. For the determination of the VHTR type, a comparative study on the reference reactors, PBR and PBR, was conducted. Based on the analytic hierarchy process (AHP) method, a systematic methodology has been developed to compare the two VHTR types. Another scheme to determine the minimum reactor power was developed as well. Regarding the hydrogen production methods, comparison indices were defined and they were applied to the IS (Iodine-Sulfur) scheme, Westinghouse process, and the, high-temperature electrolysis method. For the HTE, IS, and MMI cycle, the thermal efficiency of hydrogen production were systematically evaluated. For the IS cycle, an overall process was identified and the functionality of some key components was identified. The economy of the nuclear hydrogen was evaluated, relative to various primary energy including natural gas coal, grid-electricity, and renewable. For the international collaborations, two joint research centers were established: NH-JRC between Korea and China and NH-JDC between Korea and US. Currently, several joint researches are underway through the research centers

  12. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  13. Evaluation of an automatic uranium titration system

    International Nuclear Information System (INIS)

    Lewis, K.

    1980-01-01

    The titration system utilizes the constant current coulometric titration of Goldbeck and Lerner. U(VI) is reduced to U(IV) by Fe(II). V(V) is generated to titrate the U(IV), and the titration is followed potentiometrically. The evaluation shows that the recovery of uranium is 100% at the 40-mg level. The accuracy is generally +-0.10% or better. The smallest sample weight at which reliable results were obtained was 40 mg of uranium. Time for one analysis is 15 minutes. Advantages and disadvantages of the automated titrator are listed

  14. Fusion-fission energy systems evaluation

    International Nuclear Information System (INIS)

    Teofilo, V.L.; Aase, D.T.; Bickford, W.E.

    1980-01-01

    This report serves as the basis for comparing the fusion-fission (hybrid) energy system concept with other advanced technology fissile fuel breeding concepts evaluated in the Nonproliferation Alternative Systems Assessment Program (NASAP). As such, much of the information and data provided herein is in a form that meets the NASAP data requirements. Since the hybrid concept has not been studied as extensively as many of the other fission concepts being examined in NASAP, the provided data and information are sparse relative to these more developed concepts. Nevertheless, this report is intended to provide a perspective on hybrids and to summarize the findings of the rather limited analyses made to date on this concept

  15. Fusion-fission energy systems evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Teofilo, V.L.; Aase, D.T.; Bickford, W.E.

    1980-01-01

    This report serves as the basis for comparing the fusion-fission (hybrid) energy system concept with other advanced technology fissile fuel breeding concepts evaluated in the Nonproliferation Alternative Systems Assessment Program (NASAP). As such, much of the information and data provided herein is in a form that meets the NASAP data requirements. Since the hybrid concept has not been studied as extensively as many of the other fission concepts being examined in NASAP, the provided data and information are sparse relative to these more developed concepts. Nevertheless, this report is intended to provide a perspective on hybrids and to summarize the findings of the rather limited analyses made to date on this concept.

  16. An evaluation of classification systems for stillbirth

    Directory of Open Access Journals (Sweden)

    Pattinson Robert

    2009-06-01

    Full Text Available Abstract Background Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. Methods We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score Results InfoKeep scores were significantly different across the classifications (p ≤ 0.01 due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD score of 3.40 (0.73 followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00, 2.36 (1.21, 1.92 (1.24 respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p ≤ 0.01, all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. Conclusion The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the best agreement and a low proportion of unexplained stillbirths. The virtues of these systems need to be considered in the development of an

  17. Distributed Impact Detector System (DIDS) Health Monitoring System Evaluation

    Science.gov (United States)

    Prosser, William H.; Madaras, Eric I.

    2010-01-01

    Damage due to impacts from micrometeoroids and orbital debris is one of the most significant on-orbit hazards for spacecraft. Impacts to thermal protection systems must be detected and the damage evaluated to determine if repairs are needed to allow safe re-entry. To address this issue for the International Space Station Program, Langley Research Center and Johnson Space Center technologists have been working to develop and implement advanced methods for detecting impacts and resultant leaks. LaRC funded a Small Business Innovative Research contract to Invocon, Inc. to develop special wireless sensor systems that are compact, light weight, and have long battery lifetimes to enable applications to long duration space structures. These sensor systems are known as distributed impact detection systems (DIDS). In an assessment, the NASA Engineering and Safety Center procured two prototype DIDS sensor units to evaluate their capabilities in laboratory testing and field testing in an ISS Node 1 structural test article. This document contains the findings of the assessment.

  18. Information System Architectures: Representation, Planning and Evaluation

    Directory of Open Access Journals (Sweden)

    André Vasconcelos

    2003-12-01

    Full Text Available In recent years organizations have been faced with increasingly demanding business environments - pushed by factors like market globalization, need for product and service innovation and product life cycle reduction - and with new information technologies changes and opportunities- such as the Component-off-the-shelf paradigm, the telecommunications improvement or the Enterprise Systems off-the-shelf modules availability - all of which impose a continuous redraw and reorganization of business strategies and processes. Nowadays, Information Technology makes possible high-speed, efficient and low cost access to the enterprise information, providing the means for business processes automation and improvement. In spite of these important technological progresses, information systems that support business, do not usually answer efficiently enough to the continuous demands that organizations are faced with, causing non-alignment between business and information technologies (IT and therefore reducing organization competitive abilities. This article discusses the vital role that the definition of an Information System Architecture (ISA has in the development of Enterprise Information Systems that are capable of staying fully aligned with organization strategy and business needs. In this article the authors propose a restricted collection of founding and basis operations, which will provide the conceptual paradigm and tools for proper ISA handling. These tools are then used in order to represent, plan and evaluate an ISA of a Financial Group.

  19. Evaluating architecture impact on system energy efficiency.

    Science.gov (United States)

    Yu, Shijie; Yang, Hailong; Wang, Rui; Luan, Zhongzhi; Qian, Depei

    2017-01-01

    As the energy consumption has been surging in an unsustainable way, it is important to understand the impact of existing architecture designs from energy efficiency perspective, which is especially valuable for High Performance Computing (HPC) and datacenter environment hosting tens of thousands of servers. One obstacle hindering the advance of comprehensive evaluation on energy efficiency is the deficient power measuring approach. Most of the energy study relies on either external power meters or power models, both of these two methods contain intrinsic drawbacks in their practical adoption and measuring accuracy. Fortunately, the advent of Intel Running Average Power Limit (RAPL) interfaces has promoted the power measurement ability into next level, with higher accuracy and finer time resolution. Therefore, we argue it is the exact time to conduct an in-depth evaluation of the existing architecture designs to understand their impact on system energy efficiency. In this paper, we leverage representative benchmark suites including serial and parallel workloads from diverse domains to evaluate the architecture features such as Non Uniform Memory Access (NUMA), Simultaneous Multithreading (SMT) and Turbo Boost. The energy is tracked at subcomponent level such as Central Processing Unit (CPU) cores, uncore components and Dynamic Random-Access Memory (DRAM) through exploiting the power measurement ability exposed by RAPL. The experiments reveal non-intuitive results: 1) the mismatch between local compute and remote memory node caused by NUMA effect not only generates dramatic power and energy surge but also deteriorates the energy efficiency significantly; 2) for multithreaded application such as the Princeton Application Repository for Shared-Memory Computers (PARSEC), most of the workloads benefit a notable increase of energy efficiency using SMT, with more than 40% decline in average power consumption; 3) Turbo Boost is effective to accelerate the workload execution

  20. Evaluating architecture impact on system energy efficiency

    Science.gov (United States)

    Yu, Shijie; Wang, Rui; Luan, Zhongzhi; Qian, Depei

    2017-01-01

    As the energy consumption has been surging in an unsustainable way, it is important to understand the impact of existing architecture designs from energy efficiency perspective, which is especially valuable for High Performance Computing (HPC) and datacenter environment hosting tens of thousands of servers. One obstacle hindering the advance of comprehensive evaluation on energy efficiency is the deficient power measuring approach. Most of the energy study relies on either external power meters or power models, both of these two methods contain intrinsic drawbacks in their practical adoption and measuring accuracy. Fortunately, the advent of Intel Running Average Power Limit (RAPL) interfaces has promoted the power measurement ability into next level, with higher accuracy and finer time resolution. Therefore, we argue it is the exact time to conduct an in-depth evaluation of the existing architecture designs to understand their impact on system energy efficiency. In this paper, we leverage representative benchmark suites including serial and parallel workloads from diverse domains to evaluate the architecture features such as Non Uniform Memory Access (NUMA), Simultaneous Multithreading (SMT) and Turbo Boost. The energy is tracked at subcomponent level such as Central Processing Unit (CPU) cores, uncore components and Dynamic Random-Access Memory (DRAM) through exploiting the power measurement ability exposed by RAPL. The experiments reveal non-intuitive results: 1) the mismatch between local compute and remote memory node caused by NUMA effect not only generates dramatic power and energy surge but also deteriorates the energy efficiency significantly; 2) for multithreaded application such as the Princeton Application Repository for Shared-Memory Computers (PARSEC), most of the workloads benefit a notable increase of energy efficiency using SMT, with more than 40% decline in average power consumption; 3) Turbo Boost is effective to accelerate the workload execution

  1. Systems considerations in seismic margin evaluations

    International Nuclear Information System (INIS)

    Buttermer, D.R.

    1987-01-01

    Increasing knowledge in the geoscience field has led to the understanding that, although highly unlikely, it is possible for a nuclear power plant to be subjected to earthquake ground motion greater than that for which the plant was designed. While it is recognized that there are conservatisms inherent in current design practices, interest has developed in evaluating the seismic risk of operating plants. Several plant-specific seismic probabilistic risk assessments (SPRA) have been completed to address questions related to the seismic risk of a plant. The results from such SPRAs are quite informative, but such studies may entail a considerable amount of expensive analysis of large portions of the plant. As an alternative to an SPRA, it may be more practical to select an earthquake level above the design basis for which plant survivability is to be demonstrated. The principal question to be addressed in a seismic margin evaluation is: At what ground motion levels does one have a high confidence that the probability of seismically induced core damage is sufficiently low? In a seismic margin evaluation, an earthquake level is selected (based on site-specific geoscience considerations) for which a stable, long-term safe shutdown condition is to be demonstrated. This prespecified earthquake level is commonly referred to as the seismic margin earthquake (SME). The Electric Power Research Institute is currently supporting a research project to develop procedures for use by the utilities to allow them to perform nuclear plant seismic margin evaluations. This paper describes the systems-related aspects of these procedures

  2. INTEGRATED WATER TREATMENT SYSTEM PERFORMANCE EVALUATION

    International Nuclear Information System (INIS)

    Sexton, R.A.; Meeuwsen, W.E.

    2009-01-01

    This document describes the results of an evaluation of the current Integrated Water Treatment System (IWTS) operation against design performance and a determination of short term and long term actions recommended to sustain IWTS performance. The KW IWTS was designed to treat basin water and maintain basin clarity during fuel retrieval, washing, and packaging activities in the KW Basin. The original design was based on a mission that was limited to handling of KW Basin fuel. The use of the IWTS was extended by the decision to transfer KE fuel to KW to be cleaned and packaged using KW systems. The use was further extended for the packaging of two more Multi-Canister Overpacks (MCOs) containing legacy fuel and scrap. Planning is now in place to clean and package Knock Out Pot (KOP) Material in MCOs using these same systems. Some washing of KOP material in the Primary Cleaning Machine (PCM) is currently being done to remove material that is too small or too large to be included in the KOP Material stream. These plans will require that the IWTS remain operational through a campaign of as many as 30 additional MCOs, and has an estimated completion date in 2012. Recent operation of the IWTS during washing of canisters of KOP Material has been impacted by low pressure readings at the inlet of the P4 Booster Pump. The system provides a low pressure alarm at 10 psig, and low-low pressure interlock at 5 psig. The response to these low readings has been to lower total system flow to between 301 and 315 gpm. In addition, the IWTS operator has been required to operate the system in manual mode and make frequent adjustments to the P4 booster pump speed during PCM washes. The preferred mode of operation is to establish a setpoint of 317 gpm for the P4 pump speed and run IWTS in semi-automatic mode. Based on hydraulic modeling compared to field data presented in this report, the low P4 inlet pressure is attributed to restrictions in the 2-inch KOP inlet hose and in the KOP itself

  3. Disposal systems evaluations and tool development : Engineered Barrier System (EBS) evaluation.

    Energy Technology Data Exchange (ETDEWEB)

    Rutqvist, Jonny (LBNL); Liu, Hui-Hai (LBNL); Steefel, Carl I. (LBNL); Serrano de Caro, M. A. (LLNL); Caporuscio, Florie Andre (LANL); Birkholzer, Jens T. (LBNL); Blink, James A. (LLNL); Sutton, Mark A. (LLNL); Xu, Hongwu (LANL); Buscheck, Thomas A. (LLNL); Levy, Schon S. (LANL); Tsang, Chin-Fu (LBNL); Sonnenthal, Eric (LBNL); Halsey, William G. (LLNL); Jove-Colon, Carlos F.; Wolery, Thomas J. (LLNL)

    2011-01-01

    Key components of the nuclear fuel cycle are short-term storage and long-term disposal of nuclear waste. The latter encompasses the immobilization of used nuclear fuel (UNF) and radioactive waste streams generated by various phases of the nuclear fuel cycle, and the safe and permanent disposition of these waste forms in geological repository environments. The engineered barrier system (EBS) plays a very important role in the long-term isolation of nuclear waste in geological repository environments. EBS concepts and their interactions with the natural barrier are inherently important to the long-term performance assessment of the safety case where nuclear waste disposition needs to be evaluated for time periods of up to one million years. Making the safety case needed in the decision-making process for the recommendation and the eventual embracement of a disposal system concept requires a multi-faceted integration of knowledge and evidence-gathering to demonstrate the required confidence level in a deep geological disposal site and to evaluate long-term repository performance. The focus of this report is the following: (1) Evaluation of EBS in long-term disposal systems in deep geologic environments with emphasis on the multi-barrier concept; (2) Evaluation of key parameters in the characterization of EBS performance; (3) Identification of key knowledge gaps and uncertainties; and (4) Evaluation of tools and modeling approaches for EBS processes and performance. The above topics will be evaluated through the analysis of the following: (1) Overview of EBS concepts for various NW disposal systems; (2) Natural and man-made analogs, room chemistry, hydrochemistry of deep subsurface environments, and EBS material stability in near-field environments; (3) Reactive Transport and Coupled Thermal-Hydrological-Mechanical-Chemical (THMC) processes in EBS; and (4) Thermal analysis toolkit, metallic barrier degradation mode survey, and development of a Disposal Systems

  4. Disposal systems evaluations and tool development: Engineered Barrier System (EBS) evaluation

    International Nuclear Information System (INIS)

    Rutqvist, Jonny; Liu, Hui-Hai; Steefel, Carl I.; Serrano de Caro, M.A.; Caporuscio, Florie Andre; Birkholzer, Jens T.; Blink, James A.; Sutton, Mark A.; Xu, Hongwu; Buscheck, Thomas A.; Levy, Schon S.; Tsang, Chin-Fu; Sonnenthal, Eric; Halsey, William G.; Jove-Colon, Carlos F.; Wolery, Thomas J.

    2011-01-01

    Key components of the nuclear fuel cycle are short-term storage and long-term disposal of nuclear waste. The latter encompasses the immobilization of used nuclear fuel (UNF) and radioactive waste streams generated by various phases of the nuclear fuel cycle, and the safe and permanent disposition of these waste forms in geological repository environments. The engineered barrier system (EBS) plays a very important role in the long-term isolation of nuclear waste in geological repository environments. EBS concepts and their interactions with the natural barrier are inherently important to the long-term performance assessment of the safety case where nuclear waste disposition needs to be evaluated for time periods of up to one million years. Making the safety case needed in the decision-making process for the recommendation and the eventual embracement of a disposal system concept requires a multi-faceted integration of knowledge and evidence-gathering to demonstrate the required confidence level in a deep geological disposal site and to evaluate long-term repository performance. The focus of this report is the following: (1) Evaluation of EBS in long-term disposal systems in deep geologic environments with emphasis on the multi-barrier concept; (2) Evaluation of key parameters in the characterization of EBS performance; (3) Identification of key knowledge gaps and uncertainties; and (4) Evaluation of tools and modeling approaches for EBS processes and performance. The above topics will be evaluated through the analysis of the following: (1) Overview of EBS concepts for various NW disposal systems; (2) Natural and man-made analogs, room chemistry, hydrochemistry of deep subsurface environments, and EBS material stability in near-field environments; (3) Reactive Transport and Coupled Thermal-Hydrological-Mechanical-Chemical (THMC) processes in EBS; and (4) Thermal analysis toolkit, metallic barrier degradation mode survey, and development of a Disposal Systems

  5. Traffic Aware Planner (TAP) Flight Evaluation

    Science.gov (United States)

    Maris, John M.; Haynes, Mark A.; Wing, David J.; Burke, Kelly A.; Henderson, Jeff; Woods, Sharon E.

    2014-01-01

    NASA's Traffic Aware Planner (TAP) is a cockpit decision support tool that has the potential to achieve significant fuel and time savings when it is embedded in the data-rich Next Generation Air Transportation System (NextGen) airspace. To address a key step towards the operational deployment of TAP and the NASA concept of Traffic Aware Strategic Aircrew Requests (TASAR), a system evaluation was conducted in a representative flight environment in November, 2013. Numerous challenges were overcome to achieve this goal, including the porting of the foundational Autonomous Operations Planner (AOP) software from its original simulation-based, avionics-embedded environment to an Electronic Flight Bag (EFB) platform. A flight-test aircraft was modified to host the EFB, the TAP application, an Automatic Dependent Surveillance Broadcast (ADS-B) processor, and a satellite broadband datalink. Nine Evaluation Pilots conducted 26 hours of TAP assessments using four route profiles in the complex eastern and north-eastern United States airspace. Extensive avionics and video data were collected, supplemented by comprehensive inflight and post-flight questionnaires. TAP was verified to function properly in the live avionics and ADS-B environment, characterized by recorded data dropouts, latency, and ADS-B message fluctuations. Twelve TAP-generated optimization requests were submitted to ATC, of which nine were approved, and all of which resulted in fuel and/or time savings. Analysis of subjective workload data indicated that pilot interaction with TAP during flight operations did not induce additional cognitive loading. Additionally, analyses of post-flight questionnaire data showed that the pilots perceived TAP to be useful, understandable, intuitive, and easy to use. All program objectives were met, and the next phase of TAP development and evaluations with partner airlines is in planning for 2015.

  6. Component aging evaluation with expert systems

    International Nuclear Information System (INIS)

    Wiesemann, J.S.; Maguire, H.T. Jr.

    1988-01-01

    The age degradation of components involves a complex relationship between a variety of variables. These relationships are typically modeled using probabilistic and deterministic analyses. These methods depend upon a formal understanding of the underlying degradation mechanisms and a database of experience which allows statistical analyses to extract numerical trends. At present, not all age degradation mechanisms are adequately modeled and available data for age degradation is in most cases insufficient. In addition, these methods tend to focus upon answers to isolated questions (e.g., What is the component failure rate?) rather than the more pertinent questions concerning operations and maintenance (e.g., should the component be replaced at the next outage). Fortunately, knowledge in the form of personal experience does exist which allows plant personnel to make decisions concerning operations and maintenance. This knowledge can be modeled using expert systems. This paper discusses CAGES (Component Aging Expert System). It combines expert rules (heuristics), probabilistic models, and deterministic models to make evaluations of component aging; predict the implications for component life extension, operational readiness, maintenance effectiveness, and safety, and make recommendations for maintenance and operation

  7. Evaluation of the subaxial injury classification system

    Directory of Open Access Journals (Sweden)

    A F Joaquim

    2011-01-01

    Full Text Available Study design : Retrospective clinical study of patients treated for subaxial cervical spine trauma (SCST at a tertiary medical center. Purpose : Evaluate the validity of the Subaxial Injury Classification (SLIC system in surgical versus non-surgical decision making for SCST. Inclusion criteria : Age >12 years, presence of SCST with complete clinical and radiological (CT and MRI data. Exclusion criteria : Patients with incomplete radiographic or clinical data, pathological fractures, isolated upper cervical trauma (occiput to C2, isolated transverse process or spinous process fractures, chronic or age indeterminate fractures, isolate MRI findings, and severe systemic trauma with death prior to either surgical or non-surgical treatment. Results : Fourteen patients were treated non-surgically (C, whereas 24 were treated surgically (S. In the C group, the SLIC score ranged from 0 to 5 points (standard deviation [SD] = 1.20 points; mean 1.07; median 1. Just 1 patient had an SLIC score greater than 2 (7.1% of the patients. In the S group, the SLIC score ranged from 1 to 10 points (standard deviation [SD] = 2.03 points; mean 5.6; median 6. Just 2 patients had an SLIC score smaller than 4 (both with 1 point each, 8.3% of the total group. All the other 22 (accounting for 91.6% patients had an SLIC of 4 or more points. Conclusions : Our study suggests that the SLIC classification looks to be a promising system to aid spinal surgeons in the decision-making process of subaxial cervical trauma, but a large prospective cohort study is required.

  8. Evaluation System for Pesticides (ESPE). 1. Agricultural pesticides

    NARCIS (Netherlands)

    Emans HJB; Beek MA; Linders JBHJ

    1992-01-01

    In this report a risk assessment or evaluation system for agricultural pesticides is presented, which estimates the hazards for man and environment resulting from the use of these pesticides. The evaluation system has also been placed within the context of the Uniform System for the Evaluation of

  9. World Integrated Nuclear Evaluation System: Model documentation

    International Nuclear Information System (INIS)

    1991-12-01

    The World Integrated Nuclear Evaluation System (WINES) is an aggregate demand-based partial equilibrium model used by the Energy Information Administration (EIA) to project long-term domestic and international nuclear energy requirements. WINES follows a top-down approach in which economic growth rates, delivered energy demand growth rates, and electricity demand are projected successively to ultimately forecast total nuclear generation and nuclear capacity. WINES could be potentially used to produce forecasts for any country or region in the world. Presently, WINES is being used to generate long-term forecasts for the United States, and for all countries with commercial nuclear programs in the world, excluding countries located in centrally planned economic areas. Projections for the United States are developed for the period from 2010 through 2030, and for other countries for the period starting in 2000 or 2005 (depending on the country) through 2010. EIA uses a pipeline approach to project nuclear capacity for the period between 1990 and the starting year for which the WINES model is used. This approach involves a detailed accounting of existing nuclear generating units and units under construction, their capacities, their actual or estimated time of completion, and the estimated date of retirements. Further detail on this approach can be found in Appendix B of Commercial Nuclear Power 1991: Prospects for the United States and the World

  10. Crescent Evaluation : appendix D : crescent computer system components evaluation report

    Science.gov (United States)

    1994-02-01

    In 1990, Lockheed Integrated Systems Company (LISC) was awarded a contract, under the Crescent Demonstration Project, to demonstrate the integration of Weigh In Motion (WIM), Automatic Vehicle Classification (AVC) and Automatic Vehicle Identification...

  11. Preliminary application of a novel algorithm to monitor changes in pre-flight total peripheral resistance for prediction of post-flight orthostatic intolerance in astronauts

    Science.gov (United States)

    Arai, Tatsuya; Lee, Kichang; Stenger, Michael B.; Platts, Steven H.; Meck, Janice V.; Cohen, Richard J.

    2011-04-01

    Orthostatic intolerance (OI) is a significant challenge for astronauts after long-duration spaceflight. Depending on flight duration, 20-80% of astronauts suffer from post-flight OI, which is associated with reduced vascular resistance. This paper introduces a novel algorithm for continuously monitoring changes in total peripheral resistance (TPR) by processing the peripheral arterial blood pressure (ABP). To validate, we applied our novel mathematical algorithm to the pre-flight ABP data previously recorded from twelve astronauts ten days before launch. The TPR changes were calculated by our algorithm and compared with the TPR value estimated using cardiac output/heart rate before and after phenylephrine administration. The astronauts in the post-flight presyncopal group had lower pre-flight TPR changes (1.66 times) than those in the non-presyncopal group (2.15 times). The trend in TPR changes calculated with our algorithm agreed with the TPR trend calculated using measured cardiac output in the previous study. Further data collection and algorithm refinement are needed for pre-flight detection of OI and monitoring of continuous TPR by analysis of peripheral arterial blood pressure.

  12. Divertor Materials Evaluation System (DiMES)

    International Nuclear Information System (INIS)

    Wong, C.P.; West, W.P.; Whyte, D.G.; Bastasz, R.J.; Brooks, J.; Wampler, W.R.

    1997-11-01

    The mission of the Divertor Materials Evaluation System (DiMES) in DIII-D is to establish an integrated data base from measurements in the divertor of a tokamak in order to address some of the ITER and fusion power reactor plasma material interaction issues. Carbon and metal coatings of Be, W, V, and Mo were exposed to the steady-state outer strike point on DIII-D for 4-18 s. These short exposure times ensure controlled exposure conditions, and the extensive arrays of DIII-D divertor diagnostics provide a well-characterized plasma for modeling efforts. Postexposure analysis provides a direct measure of surface material erosion rates and the amount of retained deuterium. For carbon, these results match closely with the results of accumulated carbon deposition and erosion, and the corresponding deuterium retention of long term exposure tiles in DIII-D. Deuterium retention of different materials was measured using the 3 He(d,p) 4 He nuclear reaction. For carbon, these measurements showed peak deuterium areal density of about 8 x 10 18 D/cm 2 in a co-deposited layer about 6 microm deep, mainly at the usually detached inboard divertor leg. That layer of carbon near the inner divertor strike point has an atomic saturation concentration of D/C ∼ 0.25, which is not significantly lower than the laboratory-measured saturation retention of 0.4. Under the carbon contaminated background plasma of DIII-D, metal coatings of Be, V, Mo, and W were exposed to the steady state outer strike point under ELMing and ELM-free H-mode discharges. The rate of material erosion and tritium retention were measured. As expected, W shows the lowest erosion rate at 0.1 nm/s and the lowest deuterium uptake

  13. Improving system quality through software evaluation.

    Science.gov (United States)

    McDaniel, James G

    2002-05-01

    The role of evaluation is examined with respect to quality of software in healthcare. Of particular note is the failure of the Therac-25 radiation therapy machine. This example provides evidence of several types of defect which could have been detected and corrected using appropriate evaluation procedures. The field of software engineering has developed metrics and guidelines to assist in software evaluation but this example indicates that software evaluation must be extended beyond the formally defined interfaces of the software to its real-life operating context.

  14. Incorporating a 360 Degree Evaluation Model IOT Transform the USMC Performance Evaluation System

    Science.gov (United States)

    2005-02-08

    Incorporating a 360 Evaluation Model IOT Transform the USMC Performance Evaluation System EWS 2005 Subject Area Manpower...Incorporating a 360 Evaluation Model IOT Transform the USMC Performance Evaluation System” Contemporary...COVERED 00-00-2005 to 00-00-2005 4. TITLE AND SUBTITLE Incorporating a 360 Evaluation Model IOT Transform the USMC Performance

  15. Evaluation Criteria for the Educational Web-Information System

    Science.gov (United States)

    Seok, Soonhwa; Meyen, Edward; Poggio, John C.; Semon, Sarah; Tillberg-Webb, Heather

    2008-01-01

    This article addresses how evaluation criteria improve educational Web-information system design, and the tangible and intangible benefits of using evaluation criteria, when implemented in an educational Web-information system design. The evaluation criteria were developed by the authors through a content validation study applicable to…

  16. Applying Knowledge Management in Teacher Evaluation Systems

    Science.gov (United States)

    Essandoh, Albert

    2013-01-01

    Teacher evaluations are underused in public schools, resulting in the loss of knowledge critical to professional development. Knowledge management (KM) theory offers approaches that can lead to improvements in the effectiveness of evaluations and teacher performance. This multiple case study of 9 campuses in an exemplary school district…

  17. Sample evaluation of ontology-matching systems

    NARCIS (Netherlands)

    Hage, W.R. van; Isaac, A.; Aleksovski, Z.

    2007-01-01

    Ontology matching exists to solve practical problems. Hence, methodologies to find and evaluate solutions for ontology matching should be centered on practical problems. In this paper we propose two statistically-founded evaluation techniques to assess ontology-matching performance that are based on

  18. Telephone system operations evaluation : before AOS implementation

    Science.gov (United States)

    1999-01-01

    This study provides a detailed baseline analysis of telephone system performance before AOS : implementation. By the time of the preparation of this report, the phone system component of : AOS had not been implemented.

  19. Feedback Systems for the Marine Corps Combat Readiness Evaluation System.

    Science.gov (United States)

    1984-02-01

    evaluation is defined differently by various authors; however, Stufflebeam et al. brings together three generally accepted definitions of evaluation...to measure some attribute. In contrast, the congruence definition refers to on-going evaluation in meeting the objectives. According to Stufflebeam ...selection of objectives to be measured. Stufflebeam further indicates that the congruence definition creates a . need for the evaluator to find short term

  20. Evaluation of intelligent transport systems impact on school transport safety

    OpenAIRE

    Jankowska-Karpa Dagmara; Wacowska-Ślęzak Justyna

    2017-01-01

    The integrated system of safe transport of children to school using Intelligent Transport Systems was developed and implemented in four locations across Europe under the Safeway2School (SW2S) project, funded by the EU. The SW2S system evaluation included speed measurements and an eye-tracking experiment carried out among drivers who used the school bus route, where selected elements of the system were tested. The subject of the evaluation were the following system elements: pedestrian safety ...

  1. Economic evaluation of national identification and recording systems for pigs.

    NARCIS (Netherlands)

    Saatkamp, H.W.; Dijkhuizen, A.A.; Geers, R.; Huirne, R.B.M.; Noordhuizen, J.P.T.M.; Goedseels, V.

    1997-01-01

    Four national identification and recording (I&R) systems for the Belgian pig industry were evaluated economically, using a computer simulation model. These systems were: (1) the previous system; (2) a revised system (based on the previous one); (3) a system based on electronic identification;

  2. Uninhabited Traffic Management System Evaluator (UTME), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The key innovation of this effort is the development of an Uninhabited Aerial System (UAS) Traffic Manager Evaluator (UTME) specifically targeted at evaluating...

  3. Evaluating operating system vulnerability to memory errors.

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Kurt Brian; Bridges, Patrick G. (University of New Mexico); Pedretti, Kevin Thomas Tauke; Mueller, Frank (North Carolina State University); Fiala, David (North Carolina State University); Brightwell, Ronald Brian

    2012-05-01

    Reliability is of great concern to the scalability of extreme-scale systems. Of particular concern are soft errors in main memory, which are a leading cause of failures on current systems and are predicted to be the leading cause on future systems. While great effort has gone into designing algorithms and applications that can continue to make progress in the presence of these errors without restarting, the most critical software running on a node, the operating system (OS), is currently left relatively unprotected. OS resiliency is of particular importance because, though this software typically represents a small footprint of a compute node's physical memory, recent studies show more memory errors in this region of memory than the remainder of the system. In this paper, we investigate the soft error vulnerability of two operating systems used in current and future high-performance computing systems: Kitten, the lightweight kernel developed at Sandia National Laboratories, and CLE, a high-performance Linux-based operating system developed by Cray. For each of these platforms, we outline major structures and subsystems that are vulnerable to soft errors and describe methods that could be used to reconstruct damaged state. Our results show the Kitten lightweight operating system may be an easier target to harden against memory errors due to its smaller memory footprint, largely deterministic state, and simpler system structure.

  4. Pervious Pavement System Evaluation- Abstract 1

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, gra...

  5. Experimental Evaluation of Mountain Bike Suspension Systems

    Directory of Open Access Journals (Sweden)

    J. Titlestad

    2003-01-01

    Full Text Available A significant distinction between competitive mountain bikes is whether they have a suspension system. Research studies indicate that a suspension system gives advantages, but it is difficult to quantify the benefits because they depend on so many variables, including the physiology and psychology of the cyclist, the roughness of the track and the design of the suspension system. A laboratory based test rig has been built that allows the number of variables in the system to be reduced and test conditions to be controlled. The test rig simulates regular impacts of the rear wheel with bumps in a rolling road. The physiological variables of oxygen consumption and heart rate were measured, together with speeds and forces at various points in the system. Physiological and mechanical test results both confirm a significant benefit in using a suspension system on the simulated rough track, with oxygen consumption reduced by around 30 % and power transmitted through the pedals reduced by 30 % to 60 %.

  6. Evaluating energy saving system of data centers based on AHP and fuzzy comprehensive evaluation model

    Science.gov (United States)

    Jiang, Yingni

    2018-03-01

    Due to the high energy consumption of communication, energy saving of data centers must be enforced. But the lack of evaluation mechanisms has restrained the process on energy saving construction of data centers. In this paper, energy saving evaluation index system of data centers was constructed on the basis of clarifying the influence factors. Based on the evaluation index system, analytical hierarchy process was used to determine the weights of the evaluation indexes. Subsequently, a three-grade fuzzy comprehensive evaluation model was constructed to evaluate the energy saving system of data centers.

  7. Reverse electrodialysis : evaluation of suitable electrode systems

    NARCIS (Netherlands)

    Veerman, J.; Saakes, M.; Metz, S. J.; Harmsen, G. J.

    Reverse electrodialysis (RED) is a method for directly extracting electrical energy from salinity gradients, especially from sea and river water. For the commercial implementation of RED, the electrode system is a key component. In this paper, novel electrode systems for RED were compared with

  8. Biometric systems technology, design and performance evaluation

    CERN Document Server

    Wayman, James; Maltoni, Davide

    2005-01-01

    A reference book for anyone involved in the design, management or implementation of biometric systems, and provides all the information needed to a build reliable system. It focuses on the four most widely used types of biometric technology - speech, fingerprint, iris and face recognition.

  9. Evaluation of the Intern Forecasting System.

    Science.gov (United States)

    1992-03-01

    The Operations Research Center (ORCEN), a United States Military Academy Center of Excellence, conducted an analysis of the Intern Forecasting System...have not designed an appropriate solution that performs well in the user’s environment and assures user satisfaction. The Intern Forecasting System

  10. Advanced public transportation systems : evaluation guidelines

    Science.gov (United States)

    1994-01-01

    The Federal Transit Administration has developed the Advanced Public Transportation Systems (APTS) Program which is an integral part of the overall U.S. DOT Intelligent Vehicle Highway Systems (IVHS) effort. A major aim of the APTS Program is to prom...

  11. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional...

  12. Global Positioning System receiver evaluation results

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, R.H.

    1993-09-01

    A Sandia project currently uses an outdated Magnavox 6400 Global Positioning System (GPS) receiver as the core of its navigation system. The goal of this study was to analyze the performance of the current GPS receiver compared to newer, less expensive models and to make recommendations on how to improve the performance of the overall navigation system. This paper discusses the test methodology used to experimentally analyze the performance of different GPS receivers, the test results, and recommendations on how an upgrade should proceed. Appendices contain detailed information regarding the raw data, test hardware, and test software.

  13. Systems Evaluation at the Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [Steven Winter Associates, Inc., Norwalk, CT (United States); Puttagunta, S. [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems,this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  14. Systems Evaluation at the Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    J. Williamson and S. Puttagunta

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems, this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  15. The Evaluation Phase of Systemic Family Therapy.

    Science.gov (United States)

    Caille, Philippe

    1982-01-01

    Describes the initial evaluation phase of family therapy, which clarifies the circular interaction maintaining the symptom, the family structure, and its relationship to the therapist. Suggests using first sessions to collect data and organize it meaningfully. Presents phenomenological and mythical models of family functioning as guides for…

  16. Evaluation of the TRIMAX 280 System

    National Research Council Canada - National Science Library

    Kalberer, Jennifer

    2002-01-01

    .... A series of five JP-8 pool fires of 2500-sq ft, three JP-8 3500-sq ft pool fires with F100 engine nacelle mockup, and one JP-8 700-sq ft with F100 engine nacelle mockup were used to evaluate the 90...

  17. Evaluation of a Cyber Security System for Hospital Network.

    Science.gov (United States)

    Faysel, Mohammad A

    2015-01-01

    Most of the cyber security systems use simulated data in evaluating their detection capabilities. The proposed cyber security system utilizes real hospital network connections. It uses a probabilistic data mining algorithm to detect anomalous events and takes appropriate response in real-time. On an evaluation using real-world hospital network data consisting of incoming network connections collected for a 24-hour period, the proposed system detected 15 unusual connections which were undetected by a commercial intrusion prevention system for the same network connections. Evaluation of the proposed system shows a potential to secure protected patient health information on a hospital network.

  18. Evaluation of longitudinal joint tie bar system.

    Science.gov (United States)

    2011-09-01

    "An adequate longitudinal joint tie bar system is essential in the overall performance of concrete pavement. Excessive : longitudinal joint openings are believed to be caused by either inadequate tie bar size or spacing or improper tie bar : installa...

  19. Automatic Tracking Evaluation and Development System (ATEDS)

    Data.gov (United States)

    Federal Laboratory Consortium — The heart of the ATEDS network consists of four SGI Octane computers running the IRIX operating system and equipped with V12 hardware graphics to support synthetic...

  20. Evaluation of two typical distributed energy systems

    Science.gov (United States)

    Han, Miaomiao; Tan, Xiu

    2018-03-01

    According to the two-natural gas distributed energy system driven by gas engine driven and gas turbine, in this paper, the first and second laws of thermodynamics are used to measure the distributed energy system from the two parties of “quantity” and “quality”. The calculation results show that the internal combustion engine driven distributed energy station has a higher energy efficiency, but the energy efficiency is low; the gas turbine driven distributed energy station energy efficiency is high, but the primary energy utilization rate is relatively low. When configuring the system, we should determine the applicable natural gas distributed energy system technology plan and unit configuration plan according to the actual load factors of the project and the actual factors such as the location, background and environmental requirements of the project. “quality” measure, the utilization of waste heat energy efficiency index is proposed.

  1. An Evaluation of Enhanced Geothermal Systems Technology

    Energy Technology Data Exchange (ETDEWEB)

    Jelacic, Allan [U.S. Dept. of Energy, Washington, DC (United States); Fortuna, Raymond [U.S. Dept. of Energy, Washington, DC (United States); LaSala, Raymond [U.S. Dept. of Energy, Washington, DC (United States); Nathwani, Jay [U.S. Dept. of Energy, Washington, DC (United States); Nix, Gerald [U.S. Dept. of Energy, Washington, DC (United States); Visser, Charles [National Renewable Energy Lab. (NREL), Golden, CO (United States); Green, Bruce [National Renewable Energy Lab. (NREL), Golden, CO (United States); Renner, Joel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Blankenship, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kennedy, Mack [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bruton, Carol [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2008-04-01

    This 2008 document presents the results of an eight-month study by the Department of Energy (DOE) and its support staff at the national laboratories concerning the technological requirements to commercialize a new geothermal technology, Enhanced Geothermal Systems (EGS).

  2. Performance evaluation of communication systems via importance sampling

    NARCIS (Netherlands)

    Remondo Bueno, D.

    2000-01-01

    In the design and development of telecommunication systems, the preparation of experiments can be made more effective by predicting the system performance and its dependence on the different system parameters. This can be done by modeling the system and using performance evaluation methods. This

  3. Evaluation of the Stress Resilience Training System

    Science.gov (United States)

    2014-10-30

    Force population (Chappelle et al, 2013) and is comparable with highly tasked intelligence and remotely piloted aircraft (RPA) operations units. In...contrast to those units, burnout in our Security Forces sample was driven largely by cynicism as opposed to emotional exhaustion or concerns about...validation. Clinical Psychology & Psychotherapy , 14(4), 288-301. Doerfler, L. A., Addis, M. E., & Moran, P. W. (2002). Evaluating mental health

  4. Quantitative evaluation of the RETIMAC system

    International Nuclear Information System (INIS)

    Bain, E.E.; Fisher, R.H.; Gozani, T.; Harris, L. Jr.; Kendrick, H.; Kull, L.A.; Murri, E.L.; Ollivier, R.T.; Simmons, G.L.

    1975-01-01

    One means of raising the degree of protection afforded strategic special nuclear materials against theft and diversion is the installation of Real Time Material Control (RETIMAC) systems. The ability of RETIMAC to detect any covert attempt to steal special nuclear materials in a time frame that is adequate to contain subcritical quantities of special nuclear material within the boundaries of the material protection system and to maintain current knowledge of the quantity and location of all strategic special nuclear material was tested. A commercial-scale mixed oxide fuel fabrication plant was chosen for the study. (LK)

  5. Concept Evaluation for Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    concepts, ranging from a one-to-one copy of the electrical drive (electrical drives replaced by hydraulic dittos), to floating suspension systems mounted on hydraulic cylinders. Rough calculations of size and consequences of the different systems are presented ending up with the final concept for further...... investigation. Loads and yaw demands are based on the IEC 61400-1 standard for wind turbine design, and the loads for this examination are extrapolated from the HAWC2 aeroelastic design code. The concepts are based on a 5 MW off-shore turbine....

  6. Expert evaluation in NPP safety important systems licensing process

    International Nuclear Information System (INIS)

    Mikhail, A Yastrebenetsky; Vasilchenko, V.N.

    2001-01-01

    Expert evaluation of nuclear power plant safety important systems modernization is an integral part of these systems licensing process. The paper contains some aspects of this evaluation which are based on Ukrainian experience of VVER-1000 and VVER-440 modernization. (authors)

  7. Application of computerized land evaluation systems in Tanzania: a ...

    African Journals Online (AJOL)

    Automated Land Evaluation System (ALES) and Land Evaluation Computer System (LECS) were applied in Kilosa District, Tanzania to test their applicability and adaptability in the area within the context of low-input rainfed maize farming. The study comprised physical land suitability classification of dominant soils ...

  8. Implementing a Sensory Evaluation System in the Manufacturing ...

    African Journals Online (AJOL)

    Often the people responsible for implementing sensory evaluation systems have had no formal training in sensory evaluation and the task can seem quite daunting. This paper presents some elements that are considered important when planning the design and implementation of a sensory system for process control.

  9. Evaluation of man-machine systems - methods and problems

    International Nuclear Information System (INIS)

    1985-01-01

    The symposium gives a survey of the methods of evaluation which permit as quantitive an assessment as possible of the collaboration between men and machines. This complex of problems is of great current significance in many areas of application. The systems to be evaluated are aircraft, land vehicles and watercraft as well as process control systems. (orig./GL) [de

  10. Rhode Island Model Evaluation & Support System: Building Administrator. Edition III

    Science.gov (United States)

    Rhode Island Department of Education, 2015

    2015-01-01

    Rhode Island educators believe that implementing a fair, accurate, and meaningful educator evaluation and support system will help improve teaching, learning, and school leadership. The primary purpose of the Rhode Island Model Building Administrator Evaluation and Support System (Rhode Island Model) is to help all building administrators improve.…

  11. NNWSI project information management system concepts evaluation report. Final report

    International Nuclear Information System (INIS)

    1986-08-01

    This report is intended as a first step in developing detailed information management system specifications for the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. The current state of information management at the NNWSI Project level is investigated and an information management system (IMS) is proposed. The IMS as it relates to aspects of Project and records management is discussed. Information management concepts and prospective IMS system components are investigated. Concepts and system components include: indexing, searching, retrieval, data base management system technology, computers, storage media, computer-assisted retrieval (CAR) of microfilm, electronic imaging-based systems, optical character recognition, and communications. Performance criteria and desirable system attributes applicable to the IMS are discussed. Six conceptual system approaches capable of satisfying the performance criteria are defined. System approaches include: fully centralized microfilm system based on CAR retrieval (Approach 1), partially distributed microfilm system based on CAR retrieval (Approach 2), fully distributed microfilm system based on CAR retrieval (Approach 3), fully centralized optical disk system based on electronic image and full-text retrieval (Approach 4), partially distributed optical system based on electron image and full-text retrieval (Approach 5), and fully distributed optical disk system based on electronic image and full-text retrieval (Approach 6). Technical and cost considerations associated with the six conceptual approaches are evaluated. Technical evaluation results indicate Approach 4 is the best conceptual approach, and cost evaluation results show no significant differences among approaches. On the basis of the evaluation, Approach 4 is recommended

  12. IBM PC/IX operating system evaluation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  13. Does it work? evaluating a new pay system

    OpenAIRE

    Corby, Susan; White, Geoff; Dennison, Paul; Douglas, Fiona

    2002-01-01

    This report focuses on the evaluation of the impact of new pay systems in large, unionised multi-site organisations by the organisations themselves. Evaluation of the effectiveness of a pay system, however, does not take place in a vacuum and relates to the aims and objectives of the pay system concerned. Moreover, evaluation is not an end in itself. It is, therefore, relevant to consider if any further steps were taken as a result of evaluation. Accordingly our research questions were:\\ud • ...

  14. Distribution system reliability evaluation using credibility theory

    African Journals Online (AJOL)

    Xufeng Xu, Joydeep Mitra

    switches, the distribution system can be divided into multiple SPSS, which are connected with tie switches. For example, SPSS corresponding to feeder F1 in Figure 2 is composed of {1, 2,…, 12}. Secondly, based on the definition of SPSS, the power supply area of each feeder is analyzed by depth-first search strategy. The.

  15. A new evaluation platform for Navigation systems

    DEFF Research Database (Denmark)

    Sejerøe, Thomas Hanefeld; Poulsen, Niels Kjølstad; Ravn, Ole

    2005-01-01

    The KALMTOOL 2 toolbox is a set of MATLAB tools for state estimation for nonlinear systems. The toolbox contains functions for extended Kalman filtering as well as for two new filters called the DD1 filter and the DD2 filter. It also contains function for Uncented Kalman filters as well as three ...

  16. Document Level Assessment of Document Retrieval Systems in a Pairwise System Evaluation

    Science.gov (United States)

    Rajagopal, Prabha; Ravana, Sri Devi

    2017-01-01

    Introduction: The use of averaged topic-level scores can result in the loss of valuable data and can cause misinterpretation of the effectiveness of system performance. This study aims to use the scores of each document to evaluate document retrieval systems in a pairwise system evaluation. Method: The chosen evaluation metrics are document-level…

  17. Design Concept Evaluation Using System Throughput Model

    International Nuclear Information System (INIS)

    Sequeira, G.; Nutt, W. M.

    2004-01-01

    The U.S. Department of Energy (DOE) Office of Civilian Radioactive Waste Management (OCRWM) is currently developing the technical bases to support the submittal of a license application for construction of a geologic repository at Yucca Mountain, Nevada to the U.S. Nuclear Regulatory Commission. The Office of Repository Development (ORD) is responsible for developing the design of the proposed repository surface facilities for the handling of spent nuclear fuel and high level nuclear waste. Preliminary design activities are underway to sufficiently develop the repository surface facilities design for inclusion in the license application. The design continues to evolve to meet mission needs and to satisfy both regulatory and program requirements. A system engineering approach is being used in the design process since the proposed repository facilities are dynamically linked by a series of sub-systems and complex operations. In addition, the proposed repository facility is a major system element of the overall waste management process being developed by the OCRWM. Such an approach includes iterative probabilistic dynamic simulation as an integral part of the design evolution process. A dynamic simulation tool helps to determine if: (1) the mission and design requirements are complete, robust, and well integrated; (2) the design solutions under development meet the design requirements and mission goals; (3) opportunities exist where the system can be improved and/or optimized; and (4) proposed changes to the mission, and design requirements have a positive or negative impact on overall system performance and if design changes may be necessary to satisfy these changes. This paper will discuss the type of simulation employed to model the waste handling operations. It will then discuss the process being used to develop the Yucca Mountain surface facilities model. The latest simulation model and the results of the simulation and how the data were used in the design

  18. Performance evaluation of computer and communication systems

    CERN Document Server

    Le Boudec, Jean-Yves

    2011-01-01

    … written by a scientist successful in performance evaluation, it is based on his experience and provides many ideas not only to laymen entering the field, but also to practitioners looking for inspiration. The work can be read systematically as a textbook on how to model and test the derived hypotheses on the basis of simulations. Also, separate parts can be studied, as the chapters are self-contained. … the book can be successfully used either for self-study or as a supplementary book for a lecture. I believe that different types of readers will like it: practicing engineers and resea

  19. Management Control Systems, Evaluative Style, and Behaviour : Exploring the Concept and Behavioural Consequences of Evaluative Style

    NARCIS (Netherlands)

    J. Noeverman (Jan)

    2007-01-01

    textabstractOrganisations develop and implement performance measurement and performance evaluation systems to motivate employees to take actions that -in the end- improve organisational (financial) performance. But do these systems really influence employee behaviour as intended? This thesis shows

  20. Comparative analysis of existing food safety culture evaluation systems

    OpenAIRE

    Jespersen, Lone; Griffiths, Mansel; Wallace, Carol Anne

    2017-01-01

    The purpose of the research was firstly, to analyze existing culture evaluation systems for commonalities and differences in research quality, applied validation strategies, and content. Secondly, to suggest a simple structure of food safety cultural dimensions to help unify the culture evaluation field. To achieve these goals, a comparison of eight culture evaluation models applied to varing degrees in the food industry was conducted. The systems were found to vary significantly in applied v...

  1. STRATEGY FOR EVALUATION AND SELECTION OF SYSTEMS FOR ELECTRONIC LEARNING

    Directory of Open Access Journals (Sweden)

    Dubravka Mandušić

    2012-12-01

    Full Text Available Today`s technology supported and accelerated learning time requires constant and continuous acquisition of new knowledge. On the other hand, it does not leave enough time for additional education. Increasing number of E-learning systems, withdraws a need for precise evaluation of functionality that those systems provide; so they could be reciprocally compared. While implementing new systems for electronic learning, it is very important to pre-evaluate existing systems in order to select the one that meets all defined parameters, with low costs/investment. Proper evaluation can save time and money.

  2. Development of expert evaluation system for advanced nuclear power stations

    International Nuclear Information System (INIS)

    Yang Mengjia; Ren Junsheng; Zhou Zhiwei; Zhang Qi; Zhu Shutang

    2005-01-01

    The wheels of the nuclear power industry in China are going to roll on the fast rails soon: It is important to establish an expert evaluation system for optimally selecting new types of NPPs in the future based on scientific evaluation. Under such a background, an expert evaluation system is developed to evaluate Various types of NPPs for the following two decades by taking into account the advices of selected top specialists in Chinese nuclear power industry, and by adopting different evaluation methods. The evaluation system is designed to use the database-MS-SQL Server or Oracle for manipulating experts' knowledge and objective data for scaling NPPs by user-selected evaluation methods for evaluating NPPs. The system includes two subsystems: one is called the Data Management Module and the other called the Evaluation Arithmetic Module. The Data Management Module is used to manage expert knowledge in forms of item marks of the NPPs given by experts of nuclear engineering. The Evaluation Arithmetic Module is used to analyze and deal with the evaluation based on the data in the Database by certain designed evaluation method, and to provide the evaluation results. Based on the users' selection, the evaluation of the NPPs is processed, and the results can be dynamically listed in table or displayed in graphics. So it can be used as a consulting tool to help users make optimal selection of prospective NPPs. The system is developed in architecture of the mixture framework C/S(Client/Server) and B/S(Browse/Server), thus is safe, advanced, extensible and user- friendly. The present system is computer network based, so it can be used not only in personal PC and local network, but also in the Web Server which can be browsed by remote users. To develop such an evaluation system is an initiative R and D project in Chinese nuclear R and D activities. Although the evaluation system is far from perfect, however, the preliminary evaluation results produced by the evaluation

  3. Recent nondestructive evaluation systems using x rays

    International Nuclear Information System (INIS)

    Fujii, Masashi; Matsuura, Shigeo.

    1985-01-01

    With popularization of image memory and image processing systems, computer-aided testing (CAT) technology is finding way into the field of X-ray nondestructive inspection. Conventional methods using X-ray film are being replaced by computed radiographs using imaging plates or X-ray television, and the conventional two-dimensional projection image technology is being replaced by the CT scanner technology that offers three-dimensional images. In the field of electronic devices and parts such as semiconductors and printed circuit boards, ''TOSMICRON'' series featuring ultrahigh magnification power and outstanding operability have been developed to cope with the trend of increasing in device size and in precision requirements. These systems can be connected on line with a high-speed image processing equipment having image processing hardware to achieve unattended defect detection, size determination and classification. (author)

  4. Formulation and evaluation of ketorolac transdermal systems.

    Science.gov (United States)

    Choi, Jun Shik; Cho, Young Ah; Chun, In Koo; Jung, Sun Young; Gwak, Hye Sun

    2007-02-01

    The effects of pressure-sensitive adhesives and vehicles on the in vitro permeation of ketorolac and in vivo pharmacokinetics were studied. Duro-Tak 87-2196 showed the highest in vitro permeation profiles, and propylene glycol monolaurate-diethylene glycol monoethyl ether (DGME) (60:40, v/v) and propylene glycol monocaprylate-DGME (60:40, v/v) revealed the most favorable in vitro and in vivo results. The decreased Cmax and prolonged Tmax and half-life were obtained with the ketorolac transdermal systems compared with oral administration, indicating that the ketorolac transdermal systems may have a prolonged effect with reduced toxic event. There was an excellent relationship found between in vitro permeation flux and in vivo AUC0-infinity.

  5. MITLL 2015 Language Recognition Evaluation System Description

    Science.gov (United States)

    2016-01-27

    using SDC features BNF2: i-vector classifier trained using the BNF features STATS: i-vector classifier trained using the DNN posteriors and SDC ...features PITCH1: i-vector classifier trained using SDC and pitch features PITCH2: i-vector classifier trained using BNF and pitch features 2.1 CSAIL...The IVEC system used Shifted Delta Cepstra features as input. The SDC features used speech windowing of 20 ms length and 10 ms shift. Window DC was

  6. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Neil Todreas; Pavel Hejzlar

    2008-06-30

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

  7. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    International Nuclear Information System (INIS)

    Neil Todreas; Pavel Hejzlar

    2008-01-01

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores treated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcome the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better thermal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor

  8. Evaluation of the light weight Juggling system

    Directory of Open Access Journals (Sweden)

    Erev-Yehene Vered

    2011-12-01

    Full Text Available This paper presents the training of juggling skills, a highly complex problem of coordination, under tight time and space constraints. This training is achieved with a simple training platform, a light weight juggling platform (LWJ, and is compared to training with real balls. The principle directing the design of the platform is to obtain a simple tool. The simplification, in comparison to real world juggling, is based on the identification of invariant properties in the spatiotemporal coordination of intermediate and expert jugglers. Two classes training solutions were added to the LWJ: An audio-tactile pacing or augmented multimodal environment, and the manipulation of cognitive components of the juggling skills. The transfer to juggling with real balls was evaluated in four different experiments.

  9. Operation of inspection data acquisition and evaluation system

    International Nuclear Information System (INIS)

    Takahashi, Yoichi; Harada, Hiroshi; Watanabe, Masayuki; Sakaguchi, Makoto; Ishikawa, Masayuki

    2016-01-01

    Rokkasho Reprocessing Plant (RRP) is a large scale plant to treat a huge amount of Plutonium significant for safeguards. The LArge SCAle Reprocessing plant safeguards (LASCAR) Forum recommended an effective utilization of unattended verification systems and automated data acquisition system etc. Based on LASCAR recommendation, Nuclear Material Control Center (NMCC) has developed the inspection data acquisition system as the automated data acquisition system from the unattended verification systems (including non-destructive assay equipment, solution monitoring system and surveillance camera). The data gathered from the unattended verification system are provided to the inspection data evaluation system for the State and the IAEA. In this development, redundancy concepts for data transfer line, in order to prevent inspection data missing, were introduced, and the timely confirmation of solution behaver such as material flows and inventories by the solution monitoring can be achieved. Furthermore, for purpose of efficiency of evaluation of inspection activity for the State, NMCC has developed the inspection data evaluation system which operates automated partition of inspection data coming from each verification equipment. Additionally, the inspection data system evaluation can manage the inspection activities and their efforts. These development and operation have been funded by JSGO (Japan Safeguards Office). This paper describes development history and operation of the inspection data acquisition and evaluation system. (author)

  10. INTERNATIONAL LOGISTICS SYSTEMS DESIGN AND EFFECTIVENESS EVALUATION

    Directory of Open Access Journals (Sweden)

    N. V. Khalipova

    2015-08-01

    Full Text Available Purpose. In the paper the question of the development of a methodological approach to the determination of logistics systems’ performance and grounding of the most effective goods’ delivery schemes, based on the theory of functions and sets of multiple objects, vector optimization approaches and discrete maximum principle for multi-stage processes (phase method is considered. Methodology. To achieve the goals of the research, the model of logistic system represented by multiple object that defined by the structure and content. The object is represented by hybrid superposition, composed of sets, multi-sets, ordered sets (lists and inhomogeneous sets (sequences, corteges, which at each stage of cargo delivery present sets of technological operations of their processing, choices and decisions algorithms. Multiple structure of objects is constructive three, consisting of the carrier, signatures and axiomatic. To determine the effective scheme of delivery, applied discrete maximum principle using vector optimization criterion. Findings. In this article, logistics system of delivery is presented in the form of a multi-stage (phase of the process. Each stage reviews a plurality of discrete activities sets, which includes the possible technology cycles of operations in goods handling. At each stage of a multi-phase delivery process from the supplier to the consumer, these sets are different. Considered a model example solving the problem of vector optimization options for delivery of goods by the road in the international logistics system for the five-step process. Optimization performed on the basis of three indicators. Originality. In this paper, the choice of the most effective way of delivery goods produced using the theory of functions and sets of multiple objects, using the discrete maximum principle for multi-stage processes, based on the vector optimization criterion. At each of its stages are formed a plurality of valid solutions as

  11. Evaluation of the Embedded Firewall System

    Science.gov (United States)

    2005-03-01

    No a niffng I IN FOCO Alpha FallbackP ode: a La stPaiaY(Bljk) J r NospOr . Na oain a S.. CIN D\\ Brava -Juga F AlIaa CaP aa [ • INFO O harlie (Mission...test is used for off-loading test. Table 6 in Appendix A and Figure 9 below shows the throughput data collected from both firewall systems. The bars on...the left part of the diagram that are labeled "w/IPSEC" demonstrates the previous throughput measurements whereas the bars on the right shows the

  12. Evaluation Indicator System of Marketing Planning Ability Based on ANP

    Directory of Open Access Journals (Sweden)

    Min Jin

    2014-02-01

    Full Text Available The evaluation of “Marketing planning” curriculum in higher vocational colleges should pay attention to planning ability of students which requires a set of scientific evaluation indicator system of marketing planning ability, however, there is less in-depth study in this field, especially the quantitative research. Scientific evaluation indicator system of marketing planning ability should divide the elements of marketing planning ability reasonably, and should give them reasonable weight. Combined with document and the interview data, this paper will carry on the construction and analysis of the evaluation index system of marketing planning ability with Analytic Network Process (ANP, and use Super Decisions Software (SD to carry on the corresponding calculation and verification. Finally a set of more scientific and reasonable evaluation indicator system of marketing planning ability will be summed up.

  13. An Experimental Testbed for Evaluation of Trust and Reputation Systems

    Science.gov (United States)

    Kerr, Reid; Cohen, Robin

    To date, trust and reputation systems have often been evaluated using methods of their designers’ own devising. Recently, we demonstrated that a number of noteworthy trust and reputation systems could be readily defeated, revealing limitations in their original evaluations. Efforts in the trust and reputation community to develop a testbed have yielded a successful competition platform, ART. This testbed, however, is less suited to general experimentation and evaluation of individual trust and reputation technologies. In this paper, we propose an experimentation and evaluation testbed based directly on that used in our investigations into security vulnerabilities in trust and reputation systems for marketplaces. We demonstrate the advantages of this design, towards the development of more thorough, objective evaluations of trust and reputation systems.

  14. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  15. A Methodology for Evaluating System Performance for Radiological/Nuclear Counterterrorism Systems - Full Paper

    Energy Technology Data Exchange (ETDEWEB)

    Bredt, Ofelia P.; Holter, Gregory M.; Wood, Thomas W.

    2005-04-28

    Various countermeasure systems could be deployed against radiological/nuclear terrorism. The need to compare various systems and configurations has resulted in development of a method for estimating performance of such systems. This paper presents one such performance evaluation method.

  16. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Can You Increase Teacher Engagement with Evaluation Simply by Improving the Evaluation System?

    Science.gov (United States)

    Moskal, Adon C. M.; Stein, Sarah J.; Golding, Clinton

    2016-01-01

    We know various factors can influence how teaching staff engage with student evaluation, such as institutional policies or staff beliefs. However, little research has investigated the influence of the technical processes of an evaluation system. In this article, we present a case study of the effects of changing the technical system for…

  18. Tritium glovebox stripper system seismic design evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Grinnell, J. J. [Savannah River Site (SRS), Aiken, SC (United States); Klein, J. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-09-01

    The use of glovebox confinement at US Department of Energy (DOE) tritium facilities has been discussed in numerous publications. Glovebox confinement protects the workers from radioactive material (especially tritium oxide), provides an inert atmosphere for prevention of flammable gas mixtures and deflagrations, and allows recovery of tritium released from the process into the glovebox when a glovebox stripper system (GBSS) is part of the design. Tritium recovery from the glovebox atmosphere reduces emissions from the facility and the radiological dose to the public. Location of US DOE defense programs facilities away from public boundaries also aids in reducing radiological doses to the public. This is a study based upon design concepts to identify issues and considerations for design of a Seismic GBSS. Safety requirements and analysis should be considered preliminary. Safety requirements for design of GBSS should be developed and finalized as a part of the final design process.

  19. A Technique for Evaluating Complex System of Systems Designs

    Science.gov (United States)

    2010-05-01

    consistency with other work products and plans. The SoS LCA focused on test data and results (as well as software producibility analysis) to evaluate...associate fellow of the American Institute of Aeronautics and Astronautics and a senior member of the Institute of Electrical and Electronics ...engineer positions including the Combat Net Radio and United States Message Text Format software testing projects for the Communications- Electronics

  20. GIS in Evaluation: Utilizing the Power of Geographic Information Systems to Represent Evaluation Data

    Science.gov (United States)

    Azzam, Tarek; Robinson, David

    2013-01-01

    This article provides an introduction to geographic information systems (GIS) and how the technology can be used to enhance evaluation practice. As a tool, GIS enables evaluators to incorporate contextual features (such as accessibility of program sites or community health needs) into evaluation designs and highlights the interactions between…

  1. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Background: Rivers State has been reported to have the highest HIV prevalence of all the thirty-six states in Nigeria. HIV surveillance system generates information for timely and appropriate public health action. Evaluation of the surveillance system is vital in ensuring that the purpose of the surveillance system is being met.

  2. Evaluating the Performance of an Integrated Navigation System.

    NARCIS (Netherlands)

    Lorga, J.F.M.; Chu, Q.P.; Mulder, J.A.; Halsema, D. van

    2005-01-01

    In this paper, the authors propose to introduce and describe a newly developed precise tightly-coupled integrated navigation system. The performed experiments with the purpose of evaluating the system performance are shown. A complete description of the integrated navigation system hardware,

  3. Evaluating the Security Risks of System Using Hidden Markov Models

    African Journals Online (AJOL)

    System security assessment tools are either restricted to manual risk evaluation methodologies that are not appropriate for real-time application or used to determine the impact of certain events on the security status of networked systems. In this paper, we determine the strength of computer systems from the perspective of ...

  4. Apithology Systems Inquiry: Evaluation from a Generativist Ontology

    Directory of Open Access Journals (Sweden)

    Will Varey

    2017-03-01

    Full Text Available The ontological premise of a systems research philosophy raises some unique questions about research efficacy. The study of the relations between abstract objects in bounded contexts places systems inquiry into a specific research category. Different systems research paradigms deal with the question of research evaluation distinctively. This article examines the defining criteria for the evaluation of systems research within a generativist systems ontology. Three criteria to inform the design of generativist systems research are proposed. Their use is illustrated for the generativist systems research discipline of apithology. The proposed criteria of research validity, credibility and reliability generate a fourth criterion: systems research veracity. A heuristic for discerning the results of a generativist research design prior to its commencement is provided by an apithology triptych. The benefit of this approach is to enable the design of research of relevance, significance and importance that leads naturally to apithology systems research of consequence.

  5. Technical Evaluation Report 30: Vendor-Assisted Evaluation of a Learning Management System

    Directory of Open Access Journals (Sweden)

    Adrienne De Schutter

    2004-04-01

    Full Text Available A product evaluation was conducted of Desire2Learn, an online learning management system gaining popularity in educational institutions. Since an online trial version of the software was not available for evaluation, an inspection meeting with the vendor was arranged. This provided the evaluation team with an opportunity to examine the precautions necessary for ensuring the objectivity of a product evaluation based on vendor-supplied information. The report outlines the team’s use of evaluator-driven enquiry and a triangulated approach to information checking. The Desire2Learn product is assessed as a flexible and useful addition to the range of learning management system options.

  6. Retrospective (in-process) project evaluation system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-12-20

    The retrospective evaluation methodology, designed to measure the accomplishments of the Buildings and Community Systems projects that are either on-going or completed, is described. The Threshold Screening system and risk analysis methodologies are briefly described. The result of the addition of the retrospective (in-process) evaluation methodology to the threshold/risk analysis and resource allocation methodology is one system by which a project can be screened when it is proposed, monitored in its development, and evaluated at its completion. This report describes the methodology at this early point in its development.

  7. The City Intelligence Quotient (City IQ Evaluation System: Conception and Evaluation

    Directory of Open Access Journals (Sweden)

    Zhiqiang Wu

    2016-06-01

    Full Text Available After a systematic review of 38 current intelligent city evaluation systems (ICESs from around the world, this research analyzes the secondary and tertiary indicators of these 38 ICESs from the perspectives of scale structuring, approaches and indicator selection, and determines their common base. From this base, the fundamentals of the City Intelligence Quotient (City IQ Evaluation System are developed and five dimensions are selected after a clustering analysis. The basic version, City IQ Evaluation System 1.0, involves 275 experts from 14 high-end research institutions, which include the Chinese Academy of Engineering, the National Academy of Science and Engineering (Germany, the Royal Swedish Academy of Engineering Sciences, the Planning Management Center of the Ministry of Housing and Urban-Rural Development of China, and the Development Research Center of the State Council of China. City IQ Evaluation System 2.0 is further developed, with improvements in its universality, openness, and dynamic adjustment capability. After employing deviation evaluation methods in the IQ assessment, City IQ Evaluation System 3.0 was conceived. The research team has conducted a repeated assessment of 41 intelligent cities around the world using City IQ Evaluation System 3.0. The results have proved that the City IQ Evaluation System, developed on the basis of intelligent life, features more rational indicators selected from data sources that can offer better universality, openness, and dynamics, and is more sensitive and precise.

  8. Safety evaluation of BWR off-gas treatment systems

    International Nuclear Information System (INIS)

    Schultz, R.J.; Schmitt, R.C.

    1975-01-01

    Some of the results of a safety evaluation performed on current generic types of BWR off-gas treatment systems including cooled and ambient temperature adsorber beds and cryogenics are presented. The evaluation covered the four generic types of off-gas systems and the systems of five major vendors. This study was part of original work performed under AEC contract for the Directorate of Regulatory Standards. The analysis techniques employed for the safety evaluation of these systems include: Fault Tree Analysis; FMECA (Failure Mode Effects and Criticality Analysis); general system comparisons, contaminant, system control, and design adequacy evaluations; and resultant Off-Site Dose Calculations. The salient areas presented are some of the potential problem areas, the approach that industry has taken to mitigate or design against potential upset conditions, and areas where possible deficiencies still exist. Potential problem areas discussed include hydrogen detonation, hydrogen release to equipment areas, operator/automatic control interface, and needed engineering evaluation to insure safe system operation. Of the systems reviewed, most were in the category of advanced or improved over that commonly in use today, and a conclusion from the study was that these systems offer excellent potential for noble gas control for BWR power plants where more stringent controls may be specified -- now or in the future. (U.S.)

  9. Safety evaluation of the KNICS digital reactor protection system

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Jang, Seung Cheol; Choi, Jong Gyun

    2005-01-01

    Korean Nuclear I and C System (KNICS) project, a national research program for developing a safety-class digital system, has designed a new reactor protection system (RPS). The usage of digital equipment in a safety critical application increases the importance of a risk evaluation since microprocessors and software technologies make the digital system very complex and their unavailability is hard to quantify. This paper addresses the safety evaluation of the KNICS RPS in consideration of the several technical concerns of a safety modeling for a digital system. We also present the fault-tree modeling technique and the risk evaluation results. A fault-tree model which includes the common cause failure events, the coverage of a fault-tolerant mechanism and the software failure event is developed. Based on the minimal cut sets of the model, we discuss the system unavailability of the newly developed design of the KNICS RPS

  10. The JAERI code system for evaluation of BWR ECCS performance

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Akimoto, Masayuki; Asahi, Yoshiro; Abe, Kiyoharu; Muramatsu, Ken; Araya, Fumimasa; Sato, Kazuo

    1982-12-01

    Development of respective computer code system of BWR and PWR for evaluation of ECCS has been conducted since 1973 considering the differences of the reactor cooling system, core structure and ECCS. The first version of the BWR code system, of which developmental work started earlier than that of the PWR, has been completed. The BWR code system is designed to provide computational tools to analyze all phases of LOCAs and to evaluate the performance of the ECCS including an ''Evaluation Model (EM)'' feature in compliance with the requirements of the current Japanese Evaluation Guideline of ECCS. The BWR code system could be used for licensing purpose, i.e. for ECCS performance evaluation or audit calculations to cross-examine the methods and results of applicants or vendors. The BWR code system presented in this report comprises several computer codes, each of which analyzes a particular phase of a LOCA or a system blowdown depending on a range of LOCAs, i.e. large and small breaks in a variety of locations in the reactor system. The system includes ALARM-B1, HYDY-B1 and THYDE-B1 for analysis of the system blowdown for various break sizes, THYDE-B-REFLOOD for analysis of the reflood phase and SCORCH-B2 for the calculation of the fuel assembl hot plane temperature. When the multiple codes are used to analyze a broad range of LOCA as stated above, it is very important to evaluate the adequacy and consistency between the codes used to cover an entire break spectrum. The system consistency together with the system performance are discussed for a large commercial BWR. (author)

  11. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.; Tsui, B.

    1981-01-01

    A general computer code to simulate the imaging properties of existing and hypothetical imaging systems viewing realistic source distributions within non-uniform media. Such a code allows comparative evaluations of existing and hypothetical systems, and optimization of critical parameters of system design by maximizing the signal-to-noise ratio. To be most useful, such a code allows simulation of conventional scintillation scanners and cameras as well as single-photon and position tomographic systems

  12. Ionizing radiation detection meter systems usability evaluation. Technical memorandum

    International Nuclear Information System (INIS)

    Severs, Y.; Hughes, R.; Tack, D.; Bossi, L.L.M.

    2002-12-01

    In support of the Canadian Forces Nuclear Detection, Identification and Dosimetry project a usability trial of three Ionizing Radiation Detection Meter Systems (IRDMS) was conducted 18-22 June 2001 at Connaught Ranges. The systems evaluated: System 1: ANPDR 77 Operational System with PDR 77 Alpha/Beta probes and GPS (Global Positioning System) Training System; System 2: ADM 300C Operational System with ABP 100 Alpha/Beta probes and GPS Training System, and System 3: RAM R200 Operational System with PA 100M and RG12 Alpha/Beta probes and GPS Training System. Twelve military personnel (Private to Captain) determined compliance with the bid evaluation criteria. The counter-balanced study, based on a Latin square design, was divided into two assessment phases, an operational phase and a training system phase, which rotated three groups (of four participants each) concurrently through each IRDMS. Groups were trained in set-up, maintenance and operation of each bid IRDMS prior to evaluation. The operational evaluation consisted of a test/maintenance stand, an indoor/outdoor operational stand, and an indoor,/outdoor training system stand. Participants rated the utility and usability of each system, by measuring case of use/maintenance under a range of relevant operational and clothing conditions, compatibility with soldier tasks, compatibility with clothing, compatibility with equipment and operational environments, and case of learning (including an assessment of initial and refresher training implications). A 7-point Likert-like acceptability rating scale, which covered a range from completely unacceptable (1) to completely acceptable (7), was used to evaluate the measures. The combined weighted mean scores were 584.3 for System 1 (70 o /b), 682.0 for System 2 (81 %) and 756.9 for System 3 (90%) out of a total possible score of 840. Participants reported mean scores for System 1 between barely unacceptable and borderline for both indoor and outdoor operations. System 2

  13. Evaluation of Communication Alternatives for Intelligent Transportation Systems

    Science.gov (United States)

    2010-08-31

    The primary focus of this study involved developing a process for the evaluation of wireless technologies : for intelligent transportation systems, and for conducting experiments of potential wireless technologies : and topologies. Two wireless techn...

  14. Statewide intelligent transportation systems earmark evaluation. Part B, executive summary

    Science.gov (United States)

    2003-11-01

    As the recipient of Intelligent Transportation System (ITS) Integration Program funds, the Wisconsin Department of Transportation is required to perform a self-evaluation on each program supported by the funds. This executive summary summarizes the r...

  15. Criticality Evaluation - Cask Unloading Using the Shielded Transfer System

    International Nuclear Information System (INIS)

    Blanchard, A.; Nadeau, M.L.

    1998-01-01

    This evaluation reviewed the criticality aspects of Shielded Transfer System (STS) operation. The existing Nuclear Safety Control (NSC) elements were examined and new NSC elements were developed, as needed

  16. Exploration of nuclear power enterprise 'STAR' management performance evaluation system

    International Nuclear Information System (INIS)

    Wang Sen

    2005-01-01

    From the angle of nuclear power enterprise safety culture, this essay breaks the connotations of the safety culture down to nine aspects (target management, safety management, quality management, housekeeping, cost control, authorization management, teamwork, communication and continued improvement), with each aspect divided into five levels of star class according to its own characteristics. A comparison is made between the actualities of the enterprise and star management performance evaluation system to find out the gap and identify ways of continued improvement to elevate the enterprise management level, thereby developing a standard system of conducting qualitative and quantitative evaluation to the management process. Apart from its evaluation function, this system provides a guideline on the work orientation, method, and steps to elevate work level and capability for the managers performing specific management actions. It is also a system of measuring and evaluating the executive force of the company's management and its employees. (author)

  17. Energy and environmental evaluation of tri-generation energy systems

    International Nuclear Information System (INIS)

    Chicco, G.; Mancarella, P.

    2008-01-01

    Tri generation facilities manufactured with various technologies represent an important alternative solution for the development more efficient energy systems and low environmental impact. Are described the issues related to modelling and energy and environmental evaluation [it

  18. An Evaluation of Knowledge Base Systems for Large OWL Datasets

    National Research Council Canada - National Science Library

    Guo, Yuanbo; Pan, Zhengxiang; Heflin, Jeff

    2004-01-01

    .... To this end, we have developed the Lehigh University Benchmark (LUBM). The benchmark is intended to evaluate knowledge base systems with respect to extensional queries over a large dataset that commits to a single realistic ontology...

  19. Signature Evaluation for Thermal Infrared Countermine and IED Detection Systems

    National Research Council Canada - National Science Library

    Peters, John F; Howington, Stacy E; Ballard, Jr., Jerry; Lynch, Larry N

    2007-01-01

    .... These simulations provide information ranging from simple temperature contrasts to high-resolution images comparable to actual sensor images that can be used to evaluate or train automatic target recognition (ATR) systems...

  20. Holistic Evaluation of Lightweight Operating Systems using the PERCU Method

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, William T.C.; He, Yun (Helen); Carter, Jonathan; Glenski, Joseph; Rippe, Lynn; Cardo, Nicholas

    2008-05-01

    The scale of Leadership Class Systems presents unique challenges to the features and performance of operating system services. This paper reports results of comprehensive evaluations of two Light Weight Operating Systems (LWOS), Cray's Catamount Virtual Node (CVN) and Linux Environment (CLE) operating systems, on the exact same large-scale hardware. The evaluation was carried out over a 5-month period on NERSC's 19,480 core Cray XT-4, Franklin, using a comprehensive evaluation method that spans Performance, Effectiveness, Reliability, Consistency and Usability criteria for all major subsystems and features. The paper presents the results of the comparison between CVN and CLE, evaluates their relative strengths, and reports observations regarding the world's largest Cray XT-4 as well.

  1. Material control test and evaluation system at the ICPP

    International Nuclear Information System (INIS)

    Johnson, C.E.

    1979-01-01

    The US DOE is evaluating process monitoring as part of a total nuclear material safeguards system. A monitoring system is being installed at the Idaho Chemical Processing Plant to test and evaluate material control and surveillance concepts in an operating nuclear fuel reprocessing plant. Process monitoring for nuclear material control complements conventional safeguards accountability and physical protection to assure adherence to approved safeguards procedures and verify containment of nuclear materials within the processing plant

  2. A monitoring and evaluation system for South African higher education

    African Journals Online (AJOL)

    ... that for monitoring and evaluation to have a function beyond mere accountability and resource allocation they have to transcend the generation of baseline data and venture into the more complicated and contested terrain of explanation. For this to happen, monitoring and evaluation systems need to be deeply embedded ...

  3. Improving Teacher Evaluation Systems: Making the Most of Multiple Measures

    Science.gov (United States)

    Grissom, Jason A., Ed.; Youngs, Peter, Ed.

    2015-01-01

    This is the first book to gather and address what we have learned about the impacts and challenges of data-intensive teacher evaluation systems--a defining characteristic of the current education policy landscape. Expert researchers and practitioners speak to what we know (and what remains to be known) about evaluation measures themselves, the…

  4. thermal power stations' reliability evaluation in a hydrothermal system

    African Journals Online (AJOL)

    Dr Obe

    A quantitative tool for the evaluation of thermal power stations reliability in a hydrothermal system is presented. A reliable power station is one which would supply the required power within its installed capacity at any time within the specified voltage and frequency limits. Required for this evaluation are the station's installed ...

  5. A Coherent System of Teacher Evaluation for Quality Teaching

    Science.gov (United States)

    Adams, Tammie; Aguilar, Elena; Berg, Ellen; Cismowski, Liane; Cody, Anthony; Cohen, David B.; Dean, Sandra; Formigli, Lynn; Fung, Jane; Lee, Cliff; Marshall, Kathie; Skorko, Nancy; White, Silver

    2015-01-01

    This article addresses the questions, "How should we evaluate the quality of teaching?" and "What kind of evaluation system will move all California teachers on a path of improvement throughout their careers?" The article, adapted from a report written by a group of accomplished California teachers, recommends seven core…

  6. the evaluation of a discrete automatic analysis system

    African Journals Online (AJOL)

    1971-05-29

    May 29, 1971 ... Through the courtesy of the manufacturerst we have recently carried out a limited evaluation of the Analmatic discrete analysis system. The present study presents some of the factual data acquired during this evaluation, to- gether with a consideration of the relative advantages and disadvantages of the ...

  7. Evaluation of a Lameness Scoring System for Dairy Cows

    DEFF Research Database (Denmark)

    Thomsen, P T; Munksgaard, L; Tøgersen, F A

    2008-01-01

    Lameness is a major problem in dairy production both in terms of reduced production and compromised animal welfare. A 5-point lameness scoring system was developed based on previously published systems, but optimized for use under field conditions. The scoring system included the words "in most...... cases" in the descriptions of the clinical signs evaluated. This was done to avoid a situation in which cows might not fit into any of the categories. Additionally, a number of clinical signs used in other lameness scoring systems, considered of less importance in relation to lameness, were not included....... Only clinical signs were included that could easily be assessed within a few seconds from a distance. The scoring system was evaluated with intra-and interobserver agreement using kappa statistics. The evaluation was done before and after training 5 observers. Weighted kappa values ranged from 0...

  8. Development of EDFSRS: evaluated data files storage and retrieval system

    International Nuclear Information System (INIS)

    Hasegawa, Akira

    1985-07-01

    EDFSRS: Evaluated Data Files Storage and Retrieval System has been developed, which is a complete service system for the evaluated nuclear data files compiled in the major three formats: ENDF/B, UKNDL and KEDAK. This system intends to give efficient loading and maintenance of evaluated nuclear data files to the data base administrators and efficient retrievals to their users not only with the easiness but with the best confidence. It can give users all of the information available in these major three formats. The system consists of more than fifteen independent programs and some 150 Mega byte data files and index files (data-base) of the loaded data. In addition it is designed to be operated in the on-line TSS (Time Sharing System) mode, so that users can get any information from their desk top terminals. This report is prepared as a reference manual of the EDFSRS. (author)

  9. [Development and clinical evaluation of an anesthesia information management system].

    Science.gov (United States)

    Feng, Jing-yi; Chen, Hua; Zhu, Sheng-mei

    2010-09-21

    To study the design, implementation and clinical evaluation of an anesthesia information management system. To record, process and store peri-operative patient data automatically, all kinds of bedside monitoring equipments are connected into the system based on information integrating technology; after a statistical analysis of those patient data by data mining technology, patient status can be evaluated automatically based on risk prediction standard and decision support system, and then anesthetist could perform reasonable and safe clinical processes; with clinical processes electronically recorded, standard record tables could be generated, and clinical workflow is optimized, as well. With the system, kinds of patient data could be collected, stored, analyzed and archived, kinds of anesthesia documents could be generated, and patient status could be evaluated to support clinic decision. The anesthesia information management system is useful for improving anesthesia quality, decreasing risk of patient and clinician, and aiding to provide clinical proof.

  10. Evaluation of an intelligent open learning system for engineering education

    Directory of Open Access Journals (Sweden)

    Maria Samarakou

    2016-09-01

    Full Text Available In computer-assisted education, the continuous monitoring and assessment of the learner is crucial for the delivery of personalized education to be effective. In this paper, we present a pilot application of the Student Diagnosis, Assistance, Evaluation System based on Artificial Intelligence (StuDiAsE, an open learning system for unattended student diagnosis, assistance and evaluation based on artificial intelligence. The system demonstrated in this paper has been designed with engineering students in mind and is capable of monitoring their comprehension, assessing their prior knowledge, building individual learner profiles, providing personalized assistance and, finally, evaluating a learner's performance both quantitatively and qualitatively by means of artificial intelligence techniques. The architecture and user interface of the system are being exhibited, the results and feedback received from a pilot application of the system within a theoretical engineering course are being demonstrated and the outcomes are being discussed.

  11. Evaluation and technologic improvement of an enhanced imaging system

    International Nuclear Information System (INIS)

    Henry, D.

    1990-08-01

    Feature-based systems that combine imaging and signal analysis capabilities may be useful for nondestructive evaluation (NDE) of plant components. This report describes the metallurgical evaluation conducted to verify the performance of a feature-based system to discriminate intergranular stress corrosion cracking (IGSCC) from benign geometrical reflectors. The ultrasonic examination results were also evaluated by examination personnel trained in intergranular stress corrosion cracking (IGSCC) detection techniques. The welds were examined prior to their removal from the recirculation and Residual-Heat-Removal (RHR) piping systems of the Peach Bottom Atomic Power Plant, as described in the Phase 2 Interim Report issued in June 1989. In this phase of the program, a metallurgical evaluation was performed on piping system welds that were examined ultrasonically using a feature-based system for analysis. The feature-based system correctly identified crack, but incorrectly identified other features, e.g., root geometry and metallurgical interfaces, as cracks. While the results of the analysis by the feature-based system were not identical to the results of analysis by trained personnel, the overall performance of the feature-based system was comparable to that of the trained personnel. Based on the results of this program, the feature-based system may be useful as a supplementary method of identifying IGSCC indications. When used in conjunction with existing methods and techniques, it could improve the accuracy of IGSCC identification

  12. Design and evaluation of physical protection systems of nuclear facilities

    International Nuclear Information System (INIS)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model

  13. Evaluation of the Earth Systems Research Laboratory's global Observing System Simulation Experiment system

    Directory of Open Access Journals (Sweden)

    Nikki C. Privé

    2013-03-01

    Full Text Available An Observing System Simulation Experiment (OSSE system has been implemented at the National Oceanographic and Atmospheric Administration Earth Systems Research Laboratory in the US as part of an international Joint OSSE effort. The setup of the OSSE consists of a Nature Run from a 13-month free run of the European Center for Medium-Range Weather Forecasts operational model, synthetic observations developed at the National Centers for Environmental Prediction (NCEP and the National Aeronautics and Space Administration Global Modelling and Assimilation Office, and an operational version of the NCEP Gridpoint Statistical Interpolation data assimilation and Global Forecast System numerical weather prediction model. Synthetic observations included both conventional observations and the following radiance observations: AIRS, AMSU-A, AMSU-B, HIRS2, HIRS3, MSU, GOES radiance and OSBUV. Calibration was performed by modifying the error added to the conventional synthetic observations to achieve a match between data denial impacts on the analysis state in the OSSE system and in the real data system. Following calibration, the performance of the OSSE system was evaluated in terms of forecast skill scores and impact of observations on forecast fields.

  14. Evaluating Models of Human Performance: Safety-Critical Systems Applications

    Science.gov (United States)

    Feary, Michael S.

    2012-01-01

    This presentation is part of panel discussion on Evaluating Models of Human Performance. The purpose of this panel is to discuss the increasing use of models in the world today and specifically focus on how to describe and evaluate models of human performance. My presentation will focus on discussions of generating distributions of performance, and the evaluation of different strategies for humans performing tasks with mixed initiative (Human-Automation) systems. I will also discuss issues with how to provide Human Performance modeling data to support decisions on acceptability and tradeoffs in the design of safety critical systems. I will conclude with challenges for the future.

  15. Development of filter systems injection systems and mixing device evaluation

    International Nuclear Information System (INIS)

    Loughborough, D.

    1989-01-01

    A problem when in-situ testing High Efficiency Particulate Air (HEPA) filters is to ensure that the test aerosol provides a uniform challenge to the whole of the filter face. Uniform challenge is defined in this case as a concentration variation of aerosol across the plane of the duct of less than +/- 10%. Injecting into an open duct via a single point injector requires a minimum of 30 hydraulic duct diameters (De) between the injector and sample point to ensure a mixed flow. This may be reduced to 10De with the use of a Stairmand disc mixer. Methods of reducing the lengths of ducting required for an in-situ filter test have been investigated. Results shows that there is a minimum aerosol exit velocity below which the mixing length requirement may be substantially increased. By ensuring that this minimum velocity is exceeded, Harwell has developed a system of multiple point injectors in conjunction with a modified Stairmand disc which reduces the mixing length to 5.5De. Further work has investigated two plane devices which reduce the lengths of ducting to 4.0De, although these have an associated increased resistance to airflow

  16. Using modeling to develop and evaluate a corrective action system

    International Nuclear Information System (INIS)

    Rodgers, L.

    1995-01-01

    At a former trucking facility in EPA Region 4, a corrective action system was installed to remediate groundwater and soil contaminated with gasoline and fuel oil products released from several underground storage tanks (USTs). Groundwater modeling was used to develop the corrective action plan and later used with soil vapor modeling to evaluate the systems effectiveness. Groundwater modeling was used to determine the effects of a groundwater recovery system on the water table at the site. Information gathered during the assessment phase was used to develop a three dimensional depiction of the subsurface at the site. Different groundwater recovery schemes were then modeled to determine the most effective method for recovering contaminated groundwater. Based on the modeling and calculations, a corrective action system combining soil vapor extraction (SVE) and groundwater recovery was designed. The system included seven recovery wells, to extract both soil vapor and groundwater, and a groundwater treatment system. Operation and maintenance of the system included monthly system sampling and inspections and quarterly groundwater sampling. After one year of operation the effectiveness of the system was evaluated. A subsurface soil gas model was used to evaluate the effects of the SVE system on the site contamination as well as its effects on the water table and groundwater recovery operations. Groundwater modeling was used in evaluating the effectiveness of the groundwater recovery system. Plume migration and capture were modeled to insure that the groundwater recovery system at the site was effectively capturing the contaminant plume. The two models were then combined to determine the effects of the two systems, acting together, on the remediation process

  17. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  18. AN EVALUATION OF FIVE COMMERCIAL IMMUNOASSAY DATA ANALYSIS SOFTWARE SYSTEMS

    Science.gov (United States)

    An evaluation of five commercial software systems used for immunoassay data analysis revealed numerous deficiencies. Often, the utility of statistical output was compromised by poor documentation. Several data sets were run through each system using a four-parameter calibration f...

  19. Evaluation of the adverse drug reaction surveillance system ...

    African Journals Online (AJOL)

    The Medicines Control Authority of Zimbabwe monitors reactions to medicines through the Adverse Drugs Reactions Surveillance System. The system relies on health professionals to report adverse drug reactions to maximize patient safety. We report results of an evaluation of the Adverse Drugs Reactions Surveillance ...

  20. Median Measure: An Approach to IR Systems Evaluation.

    Science.gov (United States)

    Greisdorf, Howard; Spink, Amanda

    2001-01-01

    Results from three studies examining 1295 relevance judgments by 36 information retrieval (IR) system end-users are reported. Both the region of the relevance judgments, from non-relevant to highly relevant, and motivations or levels for the relevance judgments are examined. Implications for relevance theory and IR systems evaluation are…

  1. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  2. Concept evaluation of an inductive charging system for electric vehicles

    OpenAIRE

    Barth, H.; Jung, M.; Braun, M.; Schmülling, B.; Reker, U.

    2011-01-01

    For the user acceptance of electric vehicles a simple, reliable and safe charging process is essential. An inductive charging system can fulfill this requirement and therefore contributes to the market integration of electric vehicles. This paper presents the results of the project “W-Charge” in which a contactless inductive charging system has been developed and evaluated.

  3. Evaluation of intelligent transport systems impact on school transport safety

    Directory of Open Access Journals (Sweden)

    Jankowska-Karpa Dagmara

    2017-01-01

    Full Text Available The integrated system of safe transport of children to school using Intelligent Transport Systems was developed and implemented in four locations across Europe under the Safeway2School (SW2S project, funded by the EU. The SW2S system evaluation included speed measurements and an eye-tracking experiment carried out among drivers who used the school bus route, where selected elements of the system were tested. The subject of the evaluation were the following system elements: pedestrian safety system at the bus stop (Intelligent Bus Stop and tags for children, Driver Support System, applications for parents’ and students’ mobile phones, bus stop inventory tool and data server. A new sign designed for buses and bus stops to inform about child transportation/children waiting at the bus stop was added to the system. Training schemes for system users were also provided. The article presents evaluation results of the impact of selected elements of the SW2S system on school transport safety in Poland.

  4. Evaluation of computer-based ultrasonic inservice inspection systems

    Energy Technology Data Exchange (ETDEWEB)

    Harris, R.V. Jr.; Angel, L.J.; Doctor, S.R.; Park, W.R.; Schuster, G.J.; Taylor, T.T. [Pacific Northwest Lab., Richland, WA (United States)

    1994-03-01

    This report presents the principles, practices, terminology, and technology of computer-based ultrasonic testing for inservice inspection (UT/ISI) of nuclear power plants, with extensive use of drawings, diagrams, and LTT images. The presentation is technical but assumes limited specific knowledge of ultrasonics or computers. The report is divided into 9 sections covering conventional LTT, computer-based LTT, and evaluation methodology. Conventional LTT topics include coordinate axes, scanning, instrument operation, RF and video signals, and A-, B-, and C-scans. Computer-based topics include sampling, digitization, signal analysis, image presentation, SAFI, ultrasonic holography, transducer arrays, and data interpretation. An evaluation methodology for computer-based LTT/ISI systems is presented, including questions, detailed procedures, and test block designs. Brief evaluations of several computer-based LTT/ISI systems are given; supplementary volumes will provide detailed evaluations of selected systems.

  5. Evaluation of computer-based ultrasonic inservice inspection systems

    International Nuclear Information System (INIS)

    Harris, R.V. Jr.; Angel, L.J.; Doctor, S.R.; Park, W.R.; Schuster, G.J.; Taylor, T.T.

    1994-03-01

    This report presents the principles, practices, terminology, and technology of computer-based ultrasonic testing for inservice inspection (UT/ISI) of nuclear power plants, with extensive use of drawings, diagrams, and LTT images. The presentation is technical but assumes limited specific knowledge of ultrasonics or computers. The report is divided into 9 sections covering conventional LTT, computer-based LTT, and evaluation methodology. Conventional LTT topics include coordinate axes, scanning, instrument operation, RF and video signals, and A-, B-, and C-scans. Computer-based topics include sampling, digitization, signal analysis, image presentation, SAFI, ultrasonic holography, transducer arrays, and data interpretation. An evaluation methodology for computer-based LTT/ISI systems is presented, including questions, detailed procedures, and test block designs. Brief evaluations of several computer-based LTT/ISI systems are given; supplementary volumes will provide detailed evaluations of selected systems

  6. Tested Tools You Can Use: Evaluating Earth System Science Courses

    Science.gov (United States)

    Lee, S. P.; Prakash, A.; Reider, D.; Baker, D.

    2006-12-01

    Earth System Science Education for the 21st Century (ESSE 21) has created a public access on-line evaluation resource available at http://esse21.usra.edu/evaltoolkit in collaboration with the ESSE 21 institutions, PIs, and evaluators. The purpose of the ESSE toolkit is to offer examples of how evaluation and assessment are/have been used in Earth System Science courses and programs. Our goal is to help instructors recognize different types of assessment and evaluation tools and uses that have proved useful in these courses and provide models for designing assessments in new courses. We have included actual examples of evaluations used by ESSE institution faculty in their own courses. This is not a comprehensive toolkit on educational evaluation and assessment, but it does provide several examples of evaluations that have been used successfully in Earth System Science courses and links to many good web resources on course evaluation. We have provided examples of assessments that are designed to collect information from students before, during and after courses. Some, presented in different formats, are designed to assess what students learn, others are designed to provide course instructors with information they can use to revise their courses. These assessments range from content tests to portfolios, from feedback forms to interviews, and from concept maps to attitude surveys.

  7. An Evaluation of Information Consistency in Grid Information Systems

    CERN Document Server

    Field, Laurence

    2016-01-01

    A Grid information system resolves queries that may need to consider all information sources (Grid services), which are widely distributed geographically, in order to enable efficient Grid functions that may utilise multiple cooperating services. Fundamentally this can be achieved by either moving the query to the data (query shipping) or moving the data to the query (data shipping). Existing Grid information system implementations have adopted one of the two approaches. This paper explores the two approaches in further detail by evaluating them to the best possible extent with respect to Grid information system benchmarking metrics. A Grid information system that follows the data shipping approach based on the replication of information that aims to improve the currency for highly-mutable information is presented. An implementation of this, based on an Enterprise Messaging System, is evaluated using the benchmarking method and the consequence of the results for the design of Grid information systems is discu...

  8. Evaluation of the NDP (neutron diagnostic probe) system

    Energy Technology Data Exchange (ETDEWEB)

    Pentaleri, E.A.; Eisen, Y.Y.

    1990-12-01

    The neutron diagnostic probe (NDP), an explosive detection system developed by Consolidated Controls Corporation and based on the associated-alpha-particle technique, was evaluated. Although many problems were found with the prototype system that make it useless for most practical applications, the NDP system may be considered a successful proof-of-principle for the basic explosive detection system design. In addition to evaluating the design and performance of the present system, models were developed to estimate the performance that might reasonably be expected from full scale systems of different conceptual design. Specific examples involved various types of bulk and sheet explosives contained in a suitcase and a large crate. Also considered were the effects of innocuous materials surrounding explosives in different scenarios, including the deliberate use of shielding materials as a countermeasure to detection. 11 refs., 46 figs., 24 tabs.

  9. Physical security system effectiveness evaluation, a status report

    International Nuclear Information System (INIS)

    Todd, J.L. Jr.; Nickell, W.C.

    1975-07-01

    A method to permit objective comparisons of physical security is under development and is expected to be useful in the optimization of system design and in cost benefit analysis. The procedure involves identifying the possible or potential characteristics of a postulated adversary, the countermeasures to deny or diminish adversary success, and the response capabilities of the defender. These, in conjunction with system definition information, are evaluated by the use of analytical models which provide a means of ranking systems against threats. This paper describes the status of this effort and includes an overview of the methodology with a brief description of various models being considered for use in effectiveness evaluation. (U.S.)

  10. Experimental evaluation of an expert system for nuclear reactor operators

    International Nuclear Information System (INIS)

    Nelson, W.R.

    1984-10-01

    The United States Nuclear Regulatory Commission (USNRC) is supporting a program for the experimental evaluation of an expert system for nuclear reactor operators. A prototype expert system, called the Response Tree System, has been developed and implemented at INEL. The Response Tree System is designed to assess the status of a reactor system following an accident and recommend corrective actions to reactor operators. The system is implemented using color graphic displays and is driven by a computer simulation of the reactor system. Control of the system is accomplished using a transparent touch panel. Controlled experiments are being conducted to measure performance differences between operators using the Response Tree System and those not using it to respond to simulated accident situations. This paper summarizes the methodology and results of the evaluation of the Response Tree System, including the quantitative results obtained in the experiments thus far. Design features of the Response Tree System are discussed, and general conclusions regarding the applicability of expert systems in reactor control rooms are presented

  11. A Standardized Evaluation System for Decadal Climate Prediction

    Science.gov (United States)

    Kadow, C.; Cubasch, U.

    2012-12-01

    The evaluation of decadal prediction systems is a scientific challenge as well as a technical challenge in the climate research. The major project MiKlip (www.fona-miklip.de) for medium-term climate prediction funded by the Federal Ministry of Education and Research in Germany (BMBF) has the aim to create a model system that can provide reliable decadal forecasts on climate and weather. The model system to be developed will be novel in several aspects, with great challenges for the methodology development. This concerns especially the determination of the initial conditions, the inclusion into the model of processes relevant to decadal predictions, the increase of the spatial resolution through regionalisation, the improvement or adjustment of statistical post-processing, and finally the synthesis and validation of the entire model system. Therefore, a standardized evaluation system will be part of the MiKlip system to validate it - developed by the project 'Integrated data and evaluation system for decadal scale prediction' (INTEGRATION). The presentation gives an overview of the different linkages of such a project, shows the different development stages and gives an outlook for users and possible end users in climate service. The technical interface combines all projects inside of MiKlip and invites them to participate in a common evaluation system. The system design and the validation strategy from a standalone tool in the beginning to a user friendly web based system using GRID technologies to an integrated part of the operational MiKlip system for industry and society will give the opportunity to enhance the MiKlip strategy. First results of different possibilities of such a system will be shown to present the scientific background through Taylor diagrams, ensemble skill scores and e.g. climatological means to show the usability and possibilities of MiKlip and the INTEGRATION project.

  12. GO evaluation of a PWR spray system. Final report

    International Nuclear Information System (INIS)

    Long, W.T.

    1975-08-01

    GO is a reliability analysis methodology developed over the years from 1960 to the present by Kaman Sciences Corporation, Colorado Springs, Colorado. In this report the GO methodology is presented and its application demonstrated by performing a reliability analysis of a conceptual PWR Containment Spray System. Certain numerical results obtained are compared with those of a prior fault tree analysis of the same system as documented in the 11 January 1973 draft report, A Fault Tree Evaluation of a PWR Spray System

  13. Field Artillery Ammunition Processing System (FAAPS) concept evaluation study

    Energy Technology Data Exchange (ETDEWEB)

    Kring, C.T.; Babcock, S.M.; Watkin, D.C.; Oliver, R.P.

    1992-06-01

    The Field Artillery Ammunition Processing System (FAAPS) is an initiative to introduce a palletized load system (PLS) that is transportable with an automated ammunition processing and storage system for use on the battlefield. System proponents have targeted a 20% increase in the ammunition processing rate over the current operation while simultaneously reducing the total number of assigned field artillery battalion personnel by 30. The overall objective of the FAAPS Project is the development and demonstration of an improved process to accomplish these goals. The initial phase of the FAAPS Project and the subject of this study is the FAAPS concept evaluation. The concept evaluation consists of (1) identifying assumptions and requirements, (2) documenting the process flow, (3) identifying and evaluating technologies available to accomplish the necessary ammunition processing and storage operations, and (4) presenting alternative concepts with associated costs, processing rates, and manpower requirements for accomplishing the operation. This study provides insight into the achievability of the desired objectives.

  14. Resilient Plant Monitoring System: Design, Analysis, and Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Humberto E. Garcia; Wen-Chiao Lin; Semyon M. Meerkov; Maruthi T. Ravichandran

    2013-12-01

    Resilient monitoring systems are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools, and the performance of the overall system is evaluated using simulations. The measure of resiliency of the resulting system is evaluated using Kullback Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

  15. Quality assurance and evaluation system in japanese higher education

    Directory of Open Access Journals (Sweden)

    Ana Mami Yamaguchi

    2016-03-01

    Full Text Available Abstract In this paper we aim to contribute to the debate over accountability and assessment of higher education (HE by introducing the Japanese system. We first discuss the circumstances and issues surrounding Japanese HE and then examine the historical development of the quality assurance and evaluation system. Since the 1990s, with the implementation of policies that focused on liberalization, deregulation and increased institutional autonomy, the role of the government has shifted from setting strict regulations and quality standards to organizing an evaluation system for assessing the learning outcomes and improving accountability of the HE institutions. Finally, we suggest how Japan may take hints from Brazil in organizing an evaluation system on a national level that can more efficiently support and assess HE institutions

  16. Rural applications of Advanced Traveler Information Systems : evaluation of satellite communications systems for mayday applications

    Science.gov (United States)

    This report documents the results of an evaluation of satellite communication systems for mayday applications conducted as part of the Rural Applications of Advanced Traveler Information Systems (ATIS) study. It focuses on satellite communications sy...

  17. Using Expert Systems in Evaluation of the State of High Voltage Machine Insulation Systems

    Directory of Open Access Journals (Sweden)

    K. Záliš

    2000-01-01

    Full Text Available Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used offline diagnostic methods for the diagnostic of high voltage insulation of rotating machines, non-rotating machines and insulating oils. The CVEX expert system evaluates the discharge activity on high voltage electrical machines and equipment by means of an off-line measurement. The CVEXON expert system is for evaluating the discharge activity by on-line measurement, and the ALTONEX expert system is the expert system for on-line monitoring of rotating machines. These developed expert systems are also used for educating students (in bachelor, master and post-graduate studies and in courses which are organized for practicing engineers and technicians and for specialists in the electrical power engineering branch. A complex project has recently been set up to evaluate the measurement of partial discharges. Two parallel expert systems for evaluating partial dischatge activity on high voltage electrical machines will work at the same time in this complex evaluating system.

  18. Technical Bulletin, Evaluation of Land Application Systems: Evaluation Checklist and Supporting Commentary.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This document contains a checklist and background information for the evaluation for land application systems of wastewater. It is divided into three major sections dealing with facilities plans, design plans and specifications, and operation and maintenance manuals. The focus of section one is the thorough evaluation of alternatives and the…

  19. Methods for reliability evaluation of trust and reputation systems

    Science.gov (United States)

    Janiszewski, Marek B.

    2016-09-01

    Trust and reputation systems are a systematic approach to build security on the basis of observations of node's behaviour. Exchange of node's opinions about other nodes is very useful to indicate nodes which act selfishly or maliciously. The idea behind trust and reputation systems gets significance because of the fact that conventional security measures (based on cryptography) are often not sufficient. Trust and reputation systems can be used in various types of networks such as WSN, MANET, P2P and also in e-commerce applications. Trust and reputation systems give not only benefits but also could be a thread itself. Many attacks aim at trust and reputation systems exist, but such attacks still have not gain enough attention of research teams. Moreover, joint effects of many of known attacks have been determined as a very interesting field of research. Lack of an acknowledged methodology of evaluation of trust and reputation systems is a serious problem. This paper aims at presenting various approaches of evaluation such systems. This work also contains a description of generalization of many trust and reputation systems which can be used to evaluate reliability of such systems in the context of preventing various attacks.

  20. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    Science.gov (United States)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  1. ISOS: A job evaluation system to implement comparable worth

    Directory of Open Access Journals (Sweden)

    Albert Corominas

    2008-01-01

    Full Text Available A fair pay structure is an essential element of the personnel policy of a firm. If the pay structure is perceived as arbitrary by the members of the staff, it becomes a cause of disturbance of the labor relations. Particularly, a pay structure is unfair if it discriminates against women. Job evaluation is a traditional tool used by companies to assist in the process of determining pay structures that can be also useful to detect and combat wage discrimination, since allow determining whether two jobs are of comparable worth or not. Although there are many kinds of systems, authors agree when defining point factor methods as the most appropriate and fair job evaluation systems. However, even being well defined from a technical point of view, most existing systems give discriminatory results regarding to gender. ISOS, a new job evaluation system which is described in this paper, has been designed, with the aim to define a neutral system with regard to gender, based on present jobs characteristics, existing job evaluation systems and job description questionnaires, international experts’ knowledge and a wide body of literature on gender discrimination and its relation with job evaluation. Using ISOS can contribute to detect, combat and eliminate part of the existing wage discrimination in general and, in particular, against women. ISOS includes all aspects of the work so no characteristics are omitted. The system can be applied in any company and to evaluate any job, and offers flexibility to be adapted to the specific characteristics of an organization. ISOS can also be used to detect and combat wage discrimination. Furthermore, characteristics of present jobs, such as cross-training or flexible working time, are also included so the system can be considered innovative in a very traditional field of industrial engineering.

  2. Evaluating the success of an emergency response medical information system.

    Science.gov (United States)

    Petter, Stacie; Fruhling, Ann

    2011-07-01

    STATPack™ is an information system used to aid in the diagnosis of pathogens in hospitals and state public health laboratories. STATPack™ is used as a communication and telemedicine diagnosis tool during emergencies. This paper explores the success of this emergency response medical information system (ERMIS) using a well-known framework of information systems success developed by DeLone and McLean. Using an online survey, the entire population of STATPack™ users evaluated the success of the information system by considering system quality, information quality, system use, intention to use, user satisfaction, individual impact, and organizational impact. The results indicate that the overall quality of this ERMIS (i.e., system quality, information quality, and service quality) has a positive impact on both user satisfaction and intention to use the system. However, given the nature of ERMIS, overall quality does not necessarily predict use of the system. Moreover, the user's satisfaction with the information system positively affected the intention to use the system. User satisfaction, intention to use, and system use had a positive influence on the system's impact on the individual. Finally, the organizational impacts of the system were positively influenced by use of the system and the system's individual impact on the user. The results of the study demonstrate how to evaluate the success of an ERMIS as well as introduce potential changes in how one applies the DeLone and McLean success model in an emergency response medical information system context. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Thermal management evaluation of the complex electro-optical system

    Directory of Open Access Journals (Sweden)

    Nijemčević Srećko S.

    2017-01-01

    Full Text Available The thermal management of a complex electro-optical system aimed for outdoor application is challenging task due to the requirement of having an air-sealed enclosure, harsh working environment, and an additional thermal load generated by sunlight. It is essential to consider the effect of heating loads in the system components, as well as the internal temperature distribution, that can have influence on the system life expectancy, operational readiness and parameters, and possibility for catastrophic failure. The main objective of this paper is to analyze internal temperature distribution and evaluate its influence on system component operation capability. The electro-optical system simplified model was defined and related thermal balance simulation model based on Solid Works thermal analysis module was set and applied for temperature distribution calculation. Various outdoor environment scenarios were compared to evaluate system temperature distribution and evaluate its influence on system operation, reliability, and life time in application environment. This work was done during the design process as a part of the electro-optical system optimization. The results show that temperature distribution will not be cause for catastrophic failure and malfunction operation during operation in the expected environment.

  4. The human cardiovascular system in the absence of gravity

    Science.gov (United States)

    Bungo, M. W.; Charles, J. B.

    1985-01-01

    The data collected from a Space Shuttle crew to investigate cardiovascular changes due to microgravity are presented. The experimental procedures which involved preflight, immediate postflight, and one week following postflight echocardiograms of 13 individuals are described. The immediate postflight results reveal a 20 percent decrease in stroke volume, a 16 percent decrease in left ventricular diastolic volume index (LVDVI), no change in systolic volume, blood pressure, or cardiac index, and a 24 percent increase in heart rate. One week later a 17 percent stroke volume increase, a 29 percent increase in cardiac index, and normal blood pressure, and LVDVI were observed. It is concluded that upon reexposure to gravity a readaptation process for the cardiovascular system occurs.

  5. Evaluation of hybrid power system alternatives: a case study

    International Nuclear Information System (INIS)

    Rosenthal, Andrew L.

    1999-01-01

    Pursuant to executive and statutory policies, the National Park Service (NPS) has been evaluating the use of photovoltaic (PV) hybrid power systems, for many of its remote, off-grid areas. This paper reports the results of a detailed technical and economic evaluation for one such area: the Needles District of Canyonlands National Park. The study evaluates the presented power systems and five alternative power generation configurations, four of which utilise PV. Projections are provided for the generator run-time and fuel use associated with each configuration as well as all initial and future costs. Included in the study are specific recommendations for energy efficiency improvements at the site. Results show that the generation systems presently in use, two full-time diesel generators, has the lowest conventional 20-year life cycle costs (LCC) of the six systems evaluated. However, when emissions costs are included (per NPS guidelines), several of the PV hybrid alternatives attain a lower LCC than the diesel-only systems. General discussion of the effects of initial versus future costs of PV hybrids as they compare with engine generator system is presented. (Author)

  6. A Process For Performance Evaluation Of Real-Time Systems

    Directory of Open Access Journals (Sweden)

    Andrew J. Kornecki

    2003-12-01

    Full Text Available Real-time developers and engineers must not only meet the system functional requirements, but also the stringent timing requirements. One of the critical decisions leading to meeting these timing requirements is the selection of an operating system under which the software will be developed and run. Although there is ample documentation on real-time systems performance and evaluation, little can be found that combines such information into an efficient process for use by developers. As the software industry moves towards clearly defined processes, creation of appropriate guidelines describing a process for performance evaluation of real-time system would greatly benefit real-time developers. This technology transition research focuses on developing such a process. PROPERT (PROcess for Performance Evaluation of Real Time systems - the process described in this paper - is based upon established techniques for evaluating real-time systems. It organizes already existing real-time performance criteria and assessment techniques in a manner consistent with a well-formed process, based on the Personal Software Process concepts.

  7. Evaluating Nurses' Satisfaction With Two Nursing Information Systems.

    Science.gov (United States)

    Khajouei, Reza; Abbasi, Reza

    2017-06-01

    Evaluating user satisfaction is one of the methods to ensure the usability of information systems. Considering the importance of nursing information systems in patient health, the objective of this study is to evaluate nurses' satisfaction with two widely used nursing information systems (Peyvand Dadeh and Tirazhe) in Iran. This descriptive-analytical study was done on 230 nurses in all teaching hospitals of Kerman University of Medical Sciences in 2015. Data were collected using an augmented version of a questionnaire developed by IBM. Data were analyzed by SPSS.16 using descriptive and analytical statistical methods including t test, analysis of variance, and Pearson correlation coefficient. The mean of overall satisfaction with the two systems was 61 ± 2.2 and 74 ± 2.4, respectively. The mean of satisfaction with different systems dimensions, that is, ease of use, information quality, and interface quality, was, respectively, 24 ± 1.9, 26 ± 9.7, and 12 ± 4.7 for Tirazhe and 29 ± 1.1, 39 ± 1.04 and 13 ± 5.3 for Peyvand Dadeh system. Nurses' satisfaction with both systems was at a medium level. The majority of nurses were relatively satisfied with the information quality and user interface quality of these systems. The results suggest that designing nursing information systems in accordance with their users' need improves usability. Hence, policy and decision makers of healthcare institutions should invest on usability when purchasing such systems.

  8. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    Science.gov (United States)

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Shielding Design and Radiation Shielding Evaluation for LSDS System Facility

    International Nuclear Information System (INIS)

    Kim, Younggook; Kim, Jeongdong; Lee, Yongdeok

    2015-01-01

    As the system characteristics, the target in the spectrometer emits approximately 1012 neutrons/s. To efficiently shield the neutron, the shielding door designs are proposed for the LSDS system through a comparison of the direct shield and maze designs. Hence, to guarantee the radiation safety for the facility, the door design is a compulsory course of the development of the LSDS system. To improve the shielding rates, 250x250 covering structure was added as a subsidiary around the spectrometer. In this study, the evaluations of the suggested shielding designs were conducted using MCNP code. The suggested door design and covering structures can shield the neutron efficiently, thus all evaluations of all conditions are satisfied within the public dose limits. From the Monte Carlo code simulation, Resin(Indoor type) and Tungsten(Outdoor type) were selected as the shielding door materials. From a comparative evaluation of the door thickness, In and Out door thickness was selected 50 cm

  10. Remote Excavation System technology evaluation report: Buried Waste Robotics Program

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    This document describes the results from the Remote Excavation System demonstration and testing conducted at the Idaho National Engineering Laboratory during June and July 1993. The purpose of the demonstration was to ascertain the feasibility of the system for skimming soil and removing various types of buried waste in a safe manner and within all regulatory requirements, and to compare the performances of manual and remote operation of a backhoe. The procedures and goals of the demonstration were previously defined in The Remote Excavation System Test Plan, which served as a guideline for evaluating the various components of the system and discussed the procedures used to conduct the tests.

  11. Discriminator/time interval meter system evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Condreva, K. J.

    1976-04-12

    The purpose of this report is to discuss the evaluation of a modular prototype Discriminator/Time Interval Meter data acquisition unit as a useful tool in a digital diagnostics system. The characteristics, operation and calibration of each of the hardware components are discussed in some detail. A discussion of the system calibration, operation, and data ingestion and reduction is also given. System test results to date are given and discussed. Finally, recommendations and conclusions concerning the capabilities of the Discriminator/T.I.M. system based on test and calibration results to date are given.

  12. Remote Excavation System technology evaluation report: Buried Waste Robotics Program

    International Nuclear Information System (INIS)

    1993-09-01

    This document describes the results from the Remote Excavation System demonstration and testing conducted at the Idaho National Engineering Laboratory during June and July 1993. The purpose of the demonstration was to ascertain the feasibility of the system for skimming soil and removing various types of buried waste in a safe manner and within all regulatory requirements, and to compare the performances of manual and remote operation of a backhoe. The procedures and goals of the demonstration were previously defined in The Remote Excavation System Test Plan, which served as a guideline for evaluating the various components of the system and discussed the procedures used to conduct the tests

  13. Teleradiology: an evaluation of a microcomputer-based system.

    Science.gov (United States)

    Gayler, B W; Gitlin, J N; Rappaport, W; Skinner, F L; Cerva, J

    1981-08-01

    A laboratory evaluation of a microcomputer-based teleradiology system is described. The system used state-of-the-art hardware, and provided for contrast and brightness control by the consulting radiologists. The transmitted, digitized images were compared with conventional radiographs. The radiologists' scores for findings, impressions, and confidence levels were significantly lower for radiographic images viewed on the teleradiology system. However, the quality of the images provided by the teleradiology system was high enough to warrant further study, especially since microcomputer-based teleradiology offers the advantage of providing access to radiology services for rural areas and small hospitals.

  14. Evaluation of several corrosion protective coating systems on aluminum

    Science.gov (United States)

    Higgins, R. H.

    1981-01-01

    A study of several protective coating systems for use on aluminum in seawater/seacoast environments was conducted to review the developments made on protective coatings since early in the Space Shuttle program and to perform comparative studies on these coatings to determine their effectiveness for providing corrosion protection during exposure to seawater/seacoast environments. Panels of 2219-T87 aluminum were coated with 21 different systems and exposed to a 5 percent salt spray for 4000 hr. Application properties, adhesion measurements, heat resistance and corrosion protection were evaluated. For comparative studies, the presently specified Bostik epoxy system used on the SRB structures was included. Results of these tests indicate four systems with outstanding performance and four additional systems with protection almost as good. These systems are based on a chromated pretreatment, a chromate epoxy primer, and a polyurethane topcoat. Consideration for one of these systems should be included for those applications where superior corrosion protection for aluminum surfaces is required.

  15. Study, design and evaluation of nuclear reactor computer control system

    International Nuclear Information System (INIS)

    Menacer, S.

    1988-01-01

    Nuclear reactor control is a complex process that varies with each reactor and there is no universal agreement as to the best type of control system. After the use of conventional systems for a long time, attention turned towards digital techniques in the reactor control system. This interest emerged because of the difficulties faced in the data manipulation, mainly for post-incident analysis. However, it is not sufficient to insert a computer in a system to solve all the data-handling problems and also the insertion of a computer in a real-time system is not without any effect on the overall system. The scope of this thesis is to show the important parameters that have to be taken into account when choosing and evaluate the performances of the selected system

  16. Evaluation of Workflow Management Systems - A Meta Model Approach

    Directory of Open Access Journals (Sweden)

    Michael Rosemann

    1998-11-01

    Full Text Available The automated enactment of processes through the use of workflow management systems enables the outsourcing of the control flow from application systems. By now a large number of systems, that follow different workflow paradigms, are available. This leads to the problem of selecting the appropriate workflow management system for a given situation. In this paper we outline the benefits of a meta model approach for the evaluation and comparison of different workflow management systems. After a general introduction on the topic of meta modeling the meta models of the workflow management systems WorkParty (Siemens Nixdorf and FlowMark (IBM are compared as an example. These product specific meta models can be generalized to meta reference models, which helps to specify a workflow methodology. Exemplary, an organisational reference meta model is presented, which helps users in specifying their requirements for a workflow management system.

  17. Usability evaluation of complex systems. A literature review

    International Nuclear Information System (INIS)

    Norros, L.; Savioja, P.

    2004-04-01

    In this literature study the task of usability evaluation is approached through recent publications and known practises. The scope of the reviewed literature and the overall problematic of evaluating complex systems are first defined. Then existing evaluation methods and tools and a set of design guidelines and standards is introduced. In there view the distinction between the evaluation of the design process and evaluation of the outcome of the design process is made. Also the existing criteria for usability is provided. These criteria can be used as measures in the evaluation procedures described in the previous chapter. Then, the problem of validity in the evaluation and validation procedures of complex cognitive systems is shortly discusses. The final chapter covers the conclusions of the literature review. There is a need for deepening the relationship between usage and design. Usage must be the driver also in the design of process technology, plant's safety, and instrumentation and control as well as that of the design of man-machine interface. The collaborative activity is called activity-oriented design. In order to enable activity-oriented design we need to create design methods that drive the design activity into this direction. Criteria for evaluating what is good design are not available in present standards. Criteria for good tools and practices must consider human in a favourable role in the various tasks of operating an industrial plant as opposed to the view of human as a source of error. This is the way to create an optimal system, which takes advantage of the unique capabilities of both the human operators and the automation systems. (orig.)

  18. INPRO Methodology to evaluate the Mexico nuclear energy system

    International Nuclear Information System (INIS)

    Cruz S, R. R.; Martin del C, C.

    2016-09-01

    The International Atomic Energy Agency has developed the so-called International Project on Fuel Cycles and Innovative Nuclear Reactors (INPRO), in order to make nuclear energy available to meet the energy needs of the 21 century, in a sustainable way. One of the tasks of the project is the evaluation of the nuclear systems, to check whether they meet the objectives of the project and whether they are sustainable. This paper explains the rationale and general characteristics of the project in the evaluation of nuclear energy systems based on the concept of sustainable development. It describes the methodology developed to carry out this evaluation, divided into seven areas, such as economic, environmental, security, etc., which together make up the sustainable development of energy through nuclear systems. The economic area is analyzed and the evaluation criteria and parameters established by INPRO are discussed, in order to evaluate the Mexican nuclear energy system using Nest (software developed within the same project) as a tool to support the economic evaluation of nuclear systems. Based on the energy strategy proposed by the Energy Secretary of the Mexican Government which seeks to reduce the greenhouse gas emissions from the national electricity generation park, two types of reactor of currently available technology (A BWR and AP1000), were compared and these in turn with other alternative energy generation technologies, such as combined cycle, geothermal and wind plants. Also, the results of the application of the INPRO methodology are presented. Finally, the recommendations on actions that could lead the Mexican nuclear energy system towards sustainable development and conclusions on the application of the methodology to the Mexican case are mentioned. (Author)

  19. Health information systems evaluation frameworks: A systematic review.

    Science.gov (United States)

    Eslami Andargoli, Amirhossein; Scheepers, Helana; Rajendran, Diana; Sohal, Amrik

    2017-01-01

    Evaluation of health information systems (HISs) is complicated because of the complex nature of the health care domain. Various studies have proposed different frameworks to reduce the complexity in the assessment of these systems. The aim of these frameworks is to provide a set of guidelines for the evaluation of the adequacy of health care information systems. This paper aims to analyse studies on the evaluation of HISs by applying a content, context and process (CCP) framework to address the 'who', 'what', 'how', 'when', and 'why' of the evaluation processes used. This will allow for a better understanding of the relative strengths and weaknesses of various HISs evaluation frameworks, and will pave the way for developing a more complete framework for HISs. A systematic literature review on HIS evaluation studies was undertaken to identify the currently available HIS evaluation frameworks. Five academic databases were selected to conduct this systematic literature review. Most of the studies only address some, but not all, of the five main questions, i.e. the who, what, how, when, why, and that there was a lack of consensus in the way these questions were addressed. The critical role of context was also largely neglected in these studies. Evaluation of HISs is complex. The health care domain is highly context sensitive and in order to have a complete assessment of HISs, consideration of contextual factors is necessary. Specifically, to have the right set of criteria to measure the 'what', the answer to the 'who' of the evaluation is necessary. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Hanford high-level waste melter system evaluation data packages

    International Nuclear Information System (INIS)

    Elliott, M.L.; Shafer, P.J.; Lamar, D.A.; Merrill, R.A.; Grunewald, W.; Roth, G.; Tobie, W.

    1996-03-01

    The Tank Waste Remediation System is selecting a reference melter system for the Hanford High-Level Waste vitrification plant. A melter evaluation was conducted in FY 1994 to narrow down the long list of potential melter technologies to a few for testing. A formal evaluation was performed by a Melter Selection Working Group (MSWG), which met in June and August 1994. At the June meeting, MSWG evaluated 15 technologies and selected six for more thorough evaluation at the Aug. meeting. All 6 were variations of joule-heated or induction-heated melters. Between the June and August meetings, Hanford site staff and consultants compiled data packages for each of the six melter technologies as well as variants of the baseline technologies. Information was solicited from melter candidate vendors to supplement existing information. This document contains the data packages compiled to provide background information to MSWG in support of the evaluation of the six technologies. (A separate evaluation was performed by Fluor Daniel, Inc. to identify balance of plant impacts if a given melter system was selected.)

  1. Course Evaluation Systems for Open-ended Quality Enhancement

    DEFF Research Database (Denmark)

    Piihl, Jesper; Rasmussen, Jens Smed

    2013-01-01

    Quality in higher education is widely controlled through surveys asking students to evaluate teaching. However, control of quality does not necessarily lead to enhancement of quality. Drawing on accounting research and a case study, a measurement-based and open-ended quality control system...... emphasising quality enhancement is suggested. The case shows how interactive use of performance measurement can lead to more engaged and enabling dialogue amongst involved actors concerning quality enhancement, however institutionalised beliefs regarding course evaluation systems makes a change challenging...

  2. Evaluation of the NucleDyne Passive Containment System

    Energy Technology Data Exchange (ETDEWEB)

    Leininger, W. J.; Coleman, J. H.; Merrell, W. W.

    1981-04-01

    This reports contains: (1) an evaluation by Gilbert/Commonwealth (G/C) of the NucleDyne passive Containment System (PCS) as that conceptual design is applied to a Westinghouse, two loop, Pressurized Water Reactor; (2) an evaluation by Westinghouse of two questions about the impact of the PCS on the Nuclear Steam Supply System (NSSS), which were posed by G/C and best answered by an NSSS vendor; and (3) replies to both the Gilbert/Commonwealth report and the Westinghoue report by NucleDyne Engineering Corporation.

  3. System reliability evaluation of a touch panel manufacturing system with defect rate and reworking

    International Nuclear Information System (INIS)

    Lin, Yi-Kuei; Huang, Cheng-Fu; Chang, Ping-Chen

    2013-01-01

    In recent years, portable consumer electronic products, such as cell phone, GPS, digital camera, tablet PC, and notebook are using touch panel as interface. With the demand of touch panel increases, performance assessment is essential for touch panel production. This paper develops a method to evaluate system reliability of a touch panel manufacturing system (TPMS) with defect rate of each workstation and takes reworking actions into account. The system reliability which evaluates the possibility of demand satisfaction can provide to managers with an understanding of the system capability and can indicate possible improvements. First, we construct a capacitated manufacturing network (CMN) for a TPMS. Second, a decomposition technique is developed to determine the input flow of each workstation based on the CMN. Finally, we generate the minimal capacity vectors that should be provided to satisfy the demand. The system reliability is subsequently evaluated in terms of the minimal capacity vectors. A further decision making issue is discussed to decide a reliable production strategy. -- Graphical abstract: The proposed procedure to evaluate system reliability of the touch panel manufacturing system (TPMS). Highlights: • The system reliability of a touch panel manufacturing system (TPMS) is evaluated. • The reworking actions are taken into account in the TPMS. • A capacitated manufacturing network is constructed for the TPMS. • A procedure is proposed to evaluate system reliability of TPMS

  4. Cardiovascular System Sonographic Evaluation Algorithm: A New Sonographic Algorithm for Evaluation of the Fetal Cardiovascular System in the Second Trimester.

    Science.gov (United States)

    De León-Luis, Juan; Bravo, Coral; Gámez, Francisco; Ortiz-Quintana, Luis

    2015-07-01

    To evaluate the reproducibility and feasibility of the new cardiovascular system sonographic evaluation algorithm for studying the extended fetal cardiovascular system, including the portal, thymic, and supra-aortic areas, in the second trimester of pregnancy (19-22 weeks). We performed a cross-sectional study of pregnant women with healthy fetuses (singleton and twin pregnancies) attending our center from March to August 2011. The extended fetal cardiovascular system was evaluated by following the new algorithm, a sequential acquisition of axial views comprising the following (caudal to cranial): I, portal sinus; II, ductus venosus; III, hepatic veins; IV, 4-chamber view; V, left ventricular outflow tract; VI, right ventricular outflow tract; VII, 3-vessel and trachea view; VIII, thy-box; and IX, subclavian arteries. Interobserver agreement on the feasibility and exploration time was estimated in a subgroup of patients. The feasibility and exploration time were determined for the main cohort. Maternal, fetal, and sonographic factors affecting both features were evaluated. Interobserver agreement was excellent for all views except view VIII; the difference in the mean exploration time between observers was 1.5 minutes (95% confidence interval, 0.7-2.1 minutes; P cardiovascular system sonographic evaluation algorithm is a reproducible and feasible approach for exploration of the extended fetal cardiovascular system in a second-trimester scan. It can be used to explore these areas in normal and abnormal conditions and provides an integrated image of extended fetal cardiovascular anatomy. © 2015 by the American Institute of Ultrasound in Medicine.

  5. Reliability Evaluation of Distribution System with Distributed Generation

    Science.gov (United States)

    Chen, Guoyan; Zhang, Feng; You, Dahai; Wang, Yong; Lu, Guojun; Zou, Qi; Liu, Hengwei; Qian, Junjie; Xu, Heng

    2017-07-01

    Distribution system reliability assessment is an important part of power system reliability assessment. In recent years, distributed generations (DG) are more and more connected to distribution system because of its flexible and friendly environment features, which imposes a great influence on distribution system reliability. Hence, a reliability evaluation method suitable for distribution system with DG is imperative, which is proposed in this paper. First, a probabilistic model of DG output is established based on the generation characteristics of DG. Second, the island operation mode of distribution system with DG is researched, subsequently, the calculation method of the probability of island successful operation is put forward on the basis of DG model and the load model. Third, a reliability assessment methodology of distribution system with DG is proposed by improving the traditional minimal path algorithm for reliability evaluation of distribution system. Finally, some results are obtained by applying the proposed method to the IEEE-RBTS Bus6 system, which are consistent with the well-known facts. In this way, the proposed method is proved to be reasonable and effective.

  6. The evaluation of a web-based incident reporting system.

    Science.gov (United States)

    Kuo, Ya-Hui; Lee, Ting-Ting; Mills, Mary Etta; Lin, Kuan-Chia

    2012-07-01

    A Web-based reporting system is essential to report incident events anonymously and confidentially. The purpose of this study was to evaluate a Web-based reporting system in Taiwan. User satisfaction and impact of system use were evaluated through a survey answered by 249 nurses. Incident events reported in paper and electronic systems were collected for comparison purposes. Study variables included system user satisfaction, willingness to report, number of reports, severity of the events, and efficiency of the reporting process. Results revealed that senior nurses were less willing to report events, nurses on internal medicine units had higher satisfaction than others, and lowest satisfaction was related to the time it took to file a report. In addition, the Web-based reporting system was used more often than the paper system. The percentages of events reported were significantly higher in the Web-based system in laboratory, environment/device, and incidents occurring in other units, whereas the proportions of reports involving bedsores and dislocation of endotracheal tubes were decreased. Finally, moderate injury event reporting decreased, whereas minor or minimal injury event reporting increased. The study recommends that the data entry process be simplified and the network system be improved to increase user satisfaction and reporting rates.

  7. Evaluation of a computerized system for mechanical ventilation of infants.

    Science.gov (United States)

    Tehrani, Fleur T; Abbasi, Soraya

    2009-04-01

    To evaluate a computerized system for mechanical ventilation of infants. FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fraction of inspired oxygen (F(IO2)), minute ventilation, and control of weaning. It is used as an open-loop decision support system or as a closed-loop technique. Blood gas and ventilation data were collected from 12 infants in the neonatal intensive care at baseline and at the next round of evaluation. This data were input to open-loop version of FLEX. The system recommendations were compared to clinical determinations. FLEX recommended values for ventilation were on the average within 25% and 16.5% of the measured values at baseline and at the next round of evaluation, respectively. For F(IO2) and PEEP, FLEX recommended values were in general agreement with the clinical settings. FLEX recommendations for weaning were the same as the clinical determinations 50% of the time at baseline and 55% of the time at the next round of evaluation. FLEX did not recommend weaning for infants with weak spontaneous breathing effort or those who showed signs of dyspnea. A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.

  8. Ose evaluation of delay systems in a high threat environment

    International Nuclear Information System (INIS)

    Rich, B.L.; Cook, B.G.

    1988-01-01

    The Office of Security Evaluations (OSE) has in place an Evaluation Program to assist the Department of Energy (DOE) Headquarters and operations office managers by assessing specific elements of protection programs and informing the managers of common strengths and weaknesses of these elements. This information is provided so that sufficient and cost effective protection programs are maintained or enhanced. The subject of this paper is the evaluation of delay systems in the high-threat environment defined for sensitive DOE security interests such as special nuclear materials, nuclear weapons, and related classified devices and information

  9. 239Pu Resonance Evaluation for Thermal Benchmark System Calculations

    Science.gov (United States)

    Leal, L. C.; Noguere, G.; de Saint Jean, C.; Kahler, A. C.

    2014-04-01

    Analyses of thermal plutonium solution critical benchmark systems have indicated a deficiency in the 239Pu resonance evaluation. To investigate possible solutions to this issue, the Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) Working Party for Evaluation Cooperation (WPEC) established Subgroup 34 to focus on the reevaluation of the 239Pu resolved resonance parameters. In addition, the impacts of the prompt neutron multiplicity (νbar) and the prompt neutron fission spectrum (PFNS) have been investigated. The objective of this paper is to present the results of the 239Pu resolved resonance evaluation effort.

  10. A Group Creativity Support System for Dynamic Idea Evaluation

    DEFF Research Database (Denmark)

    Ulrich, Frank

    2015-01-01

    Idea evaluation is necessary in most modern organizations to identify the level of novelty and usefulness of new ideas. However, current idea evaluation research hinders creativity by primarily supporting convergent thinking (narrowing down ideas to a few tangible solutions), while divergent...... thinking (the development of wildly creative and novel thoughts patterns) is discounted. In this paper, this current view of idea evaluation is challenged through the development of a prototype that supports dynamic idea evaluation. The prototype uses knowledge created during evaluative processes...... to facilitate divergent thinking in a Group Creativity Support System (GCSS) designed from state-of-the-art research. The prototype is interpretively explored through a field experiment in a Danish IS research department. Consequently, the prototype demonstrates the ability to including divergent thinking...

  11. Evaluation systems for clinical governance development: a comparative study.

    Science.gov (United States)

    Hooshmand, Elaheh; Tourani, Sogand; Ravaghi, Hamid; Ebrahimipour, Hossein

    2014-01-01

    Lack of scientific and confirmed researches and expert knowledge about evaluation systems for clinical governance development in Iran have made studies on different evaluation systems for clinical governance development a necessity. These studies must provide applied strategies to design criteria of implementing clinical governance for hospital's accreditation. This is a descriptive and comparative study on development of clinical governance models all over the world. Data have been gathered by reviewing related articles. Models have been studied in comprehensive review method. The evaluated models of clinical governance development were Australian, NHS, SPOCK and OPTIGOV. The final aspects extracted from these models were Responsiveness, Policies and Strategies, Organizational Structure, Allocating Resources, Education and Occupational Development, Performance Evaluation, External Evaluation, Patient Oriented Approach, Risk Management, Personnel's Participation, Information Technology, Human Resources, Research and Development, Evidence Based Medicine, Clinical Audit, Health Technology Assessment and Quality. These results are applicable for completing the present criteria which evaluating clinical governance application and provide practical framework to evaluate country's hospital on the basis of clinical governance elements.

  12. Surveillance Systems to Track and Evaluate Obesity Prevention Efforts.

    Science.gov (United States)

    Hoelscher, Deanna M; Ranjit, Nalini; Pérez, Adriana

    2017-03-20

    To address the obesity epidemic, the public health community must develop surveillance systems that capture data at levels through which obesity prevention efforts are conducted. Current systems assess body mass index (BMI), diet, and physical activity behaviors at the individual level, but environmental and policy-related data are often lacking. The goal of this review is to describe US surveillance systems that evaluate obesity prevention efforts within the context of international trends in obesity monitoring, to identify potential data gaps, and to present recommendations to improve the evaluation of population-level initiatives. Our recommendations include adding environmental and policy measures to surveillance efforts with a focus on addressing underserved populations, harmonizing existing surveillance systems, including more sensitive measures of obesity outcomes, and developing a knowledgeable workforce. In addition, the widespread use of electronic health records and new technologies that allow self-quantification of behaviors offers opportunities for innovative surveillance methods.

  13. Physical security system effectiveness evaluation: a status report

    International Nuclear Information System (INIS)

    Todd, J.L.; Nickell, W.C.

    1975-01-01

    A method to permit objective comparisons of physical security systems is under development and is expected to be useful in the optimization of system design and in cost benefit analysis. The procedure involves identifying the possible or potential characteristics of a postulated adversary, the counter-measures to deny or diminish adversary success and the response capabilities of the defender. These, in conjunction with system definition information, are evaluated by the use of analytical models which provide a menas of ranking systems against threats. The status of this effort and an overview of the methodology with a brief description of various models being considered for use in effective evaluation are discussed. (U.S.)

  14. GESAT: System for management and evaluation of training programs

    International Nuclear Information System (INIS)

    Arjona, O.; Venegas, M.; Rodriguez, L.; Lopez, M.

    1997-01-01

    This paper describe the criteria considered to design the GESAT system, the elements considered to select the relational model, selection of the database language and the main features and possibilities of this system. GESAT allow the management of training programs based on the Systematic Approach to Training. Include the information related with all SAT phases, the results of the job analysis, training plans design, development of materials, training implementation, and the subsequent evaluation

  15. Characterization and evaluation studies on some JAERI dosimetry systems

    International Nuclear Information System (INIS)

    Kojima, T.; Sunaga, H.; Tachibana, H.; Takizawa, H.; Tanaka, R.

    2000-01-01

    Characterization and evaluation studies were carried out on some JAERI dosimetry systems, mainly alanine-ESR, in terms of the influence on the dose response of parameters such as orientation at ESR analysis, and the temperature during irradiation and analysis. Feasibility study for application of these dosimetry systems to electrons with energies lower than 4 MeV and bremsstrahlung (X rays) was also performed parallel to their reliability check through international dose intercomparison. (author)

  16. Tracer gas evaluations of push-pull ventilation system performance.

    Science.gov (United States)

    Ojima, Jun

    2009-01-01

    A push-pull ventilation system is effective for hazardous material exhaustion. Although a push-pull ventilation system has advantages over a local exhaust hood, some laborious adjustments are required. The pertinence of the adjustments is uncertain because it is difficult to evaluate the performance of a push-pull ventilation system quantitatively. In this study, a measurement of the capture efficiency of a push-pull ventilation system was carried out by means of a tracer gas method. The capture efficiency decreased to 39.3-78.5% when blockage material, a dummy worker and a cross draft, were set in the ventilation zone, but the efficiency was 95.1-97.9% when the cross draft was stopped. The results suggest that the uniform flow of a push-pull ventilation system will detour a blockage and the performance of the system will not be reduced unless a cross draft disturbs the uniform flow.

  17. Advanced transport systems analysis, modeling, and evaluation of performances

    CERN Document Server

    Janić, Milan

    2014-01-01

    This book provides a systematic analysis, modeling and evaluation of the performance of advanced transport systems. It offers an innovative approach by presenting a multidimensional examination of the performance of advanced transport systems and transport modes, useful for both theoretical and practical purposes. Advanced transport systems for the twenty-first century are characterized by the superiority of one or several of their infrastructural, technical/technological, operational, economic, environmental, social, and policy performances as compared to their conventional counterparts. The advanced transport systems considered include: Bus Rapid Transit (BRT) and Personal Rapid Transit (PRT) systems in urban area(s), electric and fuel cell passenger cars, high speed tilting trains, High Speed Rail (HSR), Trans Rapid Maglev (TRM), Evacuated Tube Transport system (ETT), advanced commercial subsonic and Supersonic Transport Aircraft (STA), conventionally- and Liquid Hydrogen (LH2)-fuelled commercial air trans...

  18. Environmental impact analysis with the airspace concept evaluation system

    Science.gov (United States)

    Augustine, Stephen; Capozzi, Brian; DiFelici, John; Graham, Michael; Thompson, Terry; Miraflor, Raymond M. C.

    2005-01-01

    The National Aeronautics and Space Administration (NASA) Ames Research Center has developed the Airspace Concept Evaluation System (ACES), which is a fast-time simulation tool for evaluating Air Traffic Management (ATM) systems. This paper describes linking a capability to ACES which can analyze the environmental impact of proposed future ATM systems. This provides the ability to quickly evaluate metrics associated with environmental impacts of aviation for inclusion in multi-dimensional cost-benefit analysis of concepts for evolution of the National Airspace System (NAS) over the next several decades. The methodology used here may be summarized as follows: 1) Standard Federal Aviation Administration (FAA) noise and emissions-inventory models, the Noise Impact Routing System (NIRS) and the Emissions and Dispersion Modeling System (EDMS), respectively, are linked to ACES simulation outputs; 2) appropriate modifications are made to ACES outputs to incorporate all information needed by the environmental models (e.g., specific airframe and engine data); 3) noise and emissions calculations are performed for all traffic and airports in the study area for each of several scenarios, as simulated by ACES; and 4) impacts of future scenarios are compared to the current NAS baseline scenario. This paper also provides the results of initial end-to-end, proof-of-concept runs of the integrated ACES and environmental-modeling capability. These preliminary results demonstrate that if no growth is likely to be impeded by significant environmental impacts that could negatively affect communities throughout the nation.

  19. Design and Evaluation Methods for Underwater Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Lin

    1996-12-31

    This thesis on underwater control systems is written with the designer in mind, assuming that the reader has some knowledge of control theory. It can be used as a text for undergraduate students and engineers. To help readers better understand the system they will be working with, the thesis is organised in a stepwise way. The reader will gain basic knowledge about underwater operations, equipment and control systems. Then the reader will be able to follow the steps to develop a required control system for an underwater equipment by first understanding the characteristics of the design problem, customer requirement, functional requirement, and possible solution, and then to present a mathematical model of the control problem. Having developed the concept, the thesis guides the reader to develop evaluation criteria and different ways to make the decision. The thesis gives an overview of how to achieve a successful design rather than giving the techniques for detailed control system design. Chapter 1 describes underwater operations and systems. Chapter 2 discusses issues of underwater control systems and control methods. Chapter 3 deals with design method and control systems theory, focusing on human-centered control. Chapter 4 discusses methods used to evaluate and rank products, and chapter 5 applies the methods to an example. 113 refs., 115 figs., 80 tabs.

  20. Decision support systems for ecosystem management: An evaluation of existing systems

    Science.gov (United States)

    H. Todd Mowrer; Klaus Barber; Joe Campbell; Nick Crookston; Cathy Dahms; John Day; Jim Laacke; Jim Merzenich; Steve Mighton; Mike Rauscher; Rick Sojda; Joyce Thompson; Peter Trenchi; Mark Twery

    1997-01-01

    This report evaluated 24 computer-aided decision support systems (DSS) that can support management decision-making in forest ecosystems. It compares the scope of each system, spatial capabilities, computational methods, development status, input and output requirements, user support availability, and system performance. Questionnaire responses from the DSS developers (...

  1. Distribution system reliability evaluation using credibility theory | Xu ...

    African Journals Online (AJOL)

    This paper describes a new method of using credibility theory to evaluate distribution system reliability. The advantage of this method lies in its ability to account for both objective and subjective uncertainty by integrating stochastic and fuzzy approaches. Equipment failures are modeled as random events, while the ...

  2. Performance Evaluation of Irbene RT-16 Radio Telescope Receiving System

    Directory of Open Access Journals (Sweden)

    Bleiders M.

    2017-12-01

    Full Text Available In the present paper, recent measurement results of refurbished Irbene RT-16 radio telescope receiving system performance are presented. The aim of the research is to evaluate characteristics of RT-16, which will allow carrying out necessary amplitude calibration in both single dish and VLBI observations, to improve the performance of existing system as well as to monitor, control and compare performance if possible changes in the receiving system will occur in future. The evaluated receiving system is 16 m Cassegrain antenna equipped with a cryogenic receiver with frequency range from 4.5 to 8.8 GHz, which is divided into four sub-bands. Multiple calibration sessions have been carried out by observing stable astronomical sources with known flux density by using in-house made total power registration backend. First, pointing offset calibration has been carried out and pointing model coefficients calculated and applied. Then, amplitude calibration, namely antenna sensitivity, calibration diode equivalent flux density and gain curve measurements have been carried out by observing calibration sources at different antenna elevations at each of the receiver sub-bands. Beam patterns have also been evaluated at different frequency bands. As a whole, acquired data will serve as a reference point for comparison in future performance evaluation of RT-16.

  3. The Assessment Agent System: Design, Development, and Evaluation

    Science.gov (United States)

    Liu, Jianhua

    2013-01-01

    This article reports the design, development, and evaluation of an online software application for assessing students' understanding of curricular content based on concept maps. This computer-based assessment program, called the Assessment Agent System, was designed by following an agent-oriented software design method. The Assessment Agent System…

  4. A Methodology for Evaluating a Systems Approach to Instructional Technology.

    Science.gov (United States)

    Felker, Daniel B.; Shettel, Harris H.

    This study was designed to develop a methodology for evaluating the application of Instructional Technology (IT), conceived of in terms of a systems approach. An idealized model of IT was prepared based on a literature review of current models. The model was matched against basic nursing education programs purporting to use IT. A rating technique…

  5. Performance evaluation of sprinkler irrigation system at Mambilla ...

    African Journals Online (AJOL)

    Variation in discharge can also be adjusted via use of uniform laterals, risers, and nozzles. This study further recommends an incorporation of a soil and water laboratory for the company to aid in monitoring the soil and water quality of the irrigation area. Keywords: Tea, irrigation System, Performance Evaluation ...

  6. Evaluation of Municipal Solid Waste Management System and ...

    African Journals Online (AJOL)

    This paper reports the evaluation of households' usage of the current solid waste management system (SWMS) within the city of Ilorin, central Nigeria and investigates the determinants of household's willingness-to-Pay (WTP) for its improvement. Data was collected with the aid of a structured questionnaire administered to ...

  7. Open Source Library Management Systems: A Multidimensional Evaluation

    Science.gov (United States)

    Balnaves, Edmund

    2008-01-01

    Open source library management systems have improved steadily in the last five years. They now present a credible option for small to medium libraries and library networks. An approach to their evaluation is proposed that takes account of three additional dimensions that only open source can offer: the developer and support community, the source…

  8. Evaluating complex fusion systems based on causal probabilistic models

    NARCIS (Netherlands)

    Mignet, F.; Pavlin, G.; de Oude, P.; da Costa, P.C.G.

    2013-01-01

    The paper evaluates a class of fusion systems that support interpretation of complex patterns consisting of large numbers of heterogeneous data obtained from distributed sources at different points in time. The fusion solutions in such domains must be able to process large quantities of

  9. Development and evaluation of a systemic assessment framework in ...

    African Journals Online (AJOL)

    The goal of a research project carried out in our department for the past five years is the development and evaluation of a systemic assessment framework based on SAQs for the high school organic chemistry. We initially focused on the potential of the SAQ scheme as well as its characteristics required to achieve in ...

  10. Magnetic Resonance Spectroscopy in evaluation of central nervous system

    International Nuclear Information System (INIS)

    Krolicki, L.; Bak, M.; Grieb, P.

    1996-01-01

    The article presents the current results of MR spectroscopy in evaluation of central nervous system. This method is useful in examination of brain ischemia, brain tumors, epilepsy; white matter disorders and degeneration diseases. MR spectroscopy is unique technique for in vivo examination of the brain in physiological and pathophysiological states. (author)

  11. Quality evaluation of the educational systems & educational administration and institutions

    OpenAIRE

    Pazhakh, A. R.

    2006-01-01

    The quality evaluation of educational systems as well as educational administration andinstitutions are described and discussed. Different analytical and conceptual approaches to these points are given. Conclusions are drawn and future lines of research in these topics are suggested and pointed out.

  12. Development of an operations evaluation system for sinking EDM

    NARCIS (Netherlands)

    Lauwers, B.; Oosterling, J.A.J.; Vanderauwera, W.

    2010-01-01

    This paper describes the development and validation of an operations evaluation system for sinking EDM operations. Based on a given workpiece geometry (e.g. mould), regions to be EDM'ed are automatically indentified. For a given electrode configuration, consisting of one or more regions, EDM

  13. RISE Evaluation and Development System: Student Learning Objectives Handbook

    Science.gov (United States)

    Indiana Department of Education, 2016

    2016-01-01

    With the help of teachers and leaders throughout the state, the Indiana Department of Education has developed an optional model teacher evaluation system named RISE. Whether corporations choose to adopt RISE or a model of their own, the department's goal is to assist corporations in developing or adopting models that both comply with IC 20-28-11.5…

  14. A Systems Approach to Evaluate One Health Initiatives

    DEFF Research Database (Denmark)

    Rüegg, Simon R.; Nielsen, Liza Rosenbaum; Buttigieg, Sandra C.

    2018-01-01

    , they intend to influence a system with a view to improve human, animal and environmental health. The NEOH evaluation framework consists of four overarching elements, namely: (1) the definition of the initiative and its context, (2) the description of the theory of change (TOC) with an assessment of expected...

  15. Influence of core self-evaluation and reward system on ...

    African Journals Online (AJOL)

    This study investigated the influence of core self-evaluation (self efficacy, self esteem, work locus of control and neuroticism) and reward system on career commitment of local government employees in Oyo State, Nigeria. Descriptive survey research design was adopted in the study and using stratified random of equal ...

  16. thermal power stations' reliability evaluation in a hydrothermal system

    African Journals Online (AJOL)

    Dr Obe

    R. C. OKONKWO. Department of Electrical Engineering. UNIVERSITY OF NIGERIA. NSUKKA. ABSTRACT. A quantitative tool for the evaluation of thermal power stations reliability in a hydrothermal system is presented. A reliable power station is one which would supply the required power within its installed capacity at any ...

  17. Development of an NPP residual lifetime evaluation system

    International Nuclear Information System (INIS)

    Regano, M.; Ibanez, M.; Hevia, F.

    1993-01-01

    Various reasons have given rise to the need for residual life management of Spain's nuclear power plants which lead to the a project for the development of a residual lifetime evaluation system managed by UNESA and supported by the owner groups. This project is described. 1 fig

  18. performance evaluation of sprinkler irrigation system at mambilla ...

    African Journals Online (AJOL)

    HOD

    PERFORMANCE EVALUATION OF SPRINKLER IRRIGATION SYSTEM AT MAMBILLA. BEVERAGE LIMITED, KAKARA-GEMBU, TARABA STATE-NIGERIA. F. G. Ngasoh1 C. C. Anyadike2, *, C. C. Mbajiorgu3 and M. N. Usman4. 1, 2, 3, 4 DEPT. OF AGRICULTURAL & BIORESOURCES ENGINEERING, UNIV. OF NIGERIA ...

  19. Evaluation of forest management systems under risk of wildfire

    Science.gov (United States)

    Kari Hyytiainen; Robert G. Haight

    2010-01-01

    We evaluate the economic efficiency of even- and uneven-aged management systems under risk of wildfire. The management problems are formulated for a mixed-conifer stand and approximations of the optimal solutions are obtained using simulation optimization. The Northern Idaho variant of the Forest Vegetation Simulator and its Fire and Fuels Extension is used to predict...

  20. Texas Teacher Evaluation & Support System (T-TESS) Appraiser Handbook

    Science.gov (United States)

    Texas Education Agency, 2016

    2016-01-01

    The Texas Education Agency's (TEA) approved instrument for evaluating teachers, the Professional Development and Appraisal System (PDAS), was the primary instrument used by 86 percent of local education agencies (LEAs) in the state and has been in place since 1997. In acknowledging the vital roles teachers play in student achievement, and based on…

  1. System for Evaluating Powerlifting and Other Multievent Performances.

    Science.gov (United States)

    Bishop, Phillip A; Williams, Tyler D; Heldman, Alex N; Vanderburgh, Paul M

    2018-01-01

    Bishop, PA, Williams, TD, Heldman, AN, and Vanderburgh, PM. System for evaluating powerlifting and other multievent performances. J Strength Cond Res 32(1): 201-204, 2018-Currently, the sport of powerlifting discriminates against bench press scores and uses an empirical equation which is very difficult to update to determine the best lifter within sex. The purpose of this study was to provide a simple and statistically sound method for evaluating powerlifting performance which could also be used with other multievent sports. Data were collected from a large public database on the top 50 (men) or the top 30 (women) individual raw competition scores in each weight class for each of the 3 powerlifting lifts. Mean and SDs were then calculated for each lift and weight class by sex. Powerlifting performance was evaluated by the sum of the 3 z-scores for the 3 lifts divided by 3 (the highest score wins). The z-scores reflect a dimensionless number which can be used to evaluate each lift and the total of the 3 lifts across weight classes and between sexes. Although the mean and SDs should be relatively stable, this computation is transparent and can be readily updated as lifters improve. This system overcomes the bias against bench press and many of the measurement challenges in evaluating athletes in multievent sports, in multiple weight divisions, and between sexes. These findings can benefit coaches and athletes by allowing simpler evaluations of performance and improvement.

  2. Evaluation methodology for fixed-site physical protection systems

    International Nuclear Information System (INIS)

    Bennett, H.A.; Olascoaga, M.T.

    1980-01-01

    A system performance evaluation methodology has been developed to aid the Nuclear Regulatory Commission (NRC) in the implementation of new regulations designed to upgrade the physical protection of nuclear fuel cycle facilities. The evaluation methodology, called Safeguards Upgrade Rule Evaluation (SURE), provides a means of explicitly incorporating measures for highly important and often difficult to quantify performance factors, e.g., installation, maintenance, training and proficiency levels, compatibility of components in subsystems, etc. This is achieved by aggregating responses to component and system questionaires through successive levels of a functional hierarchy developed for each primary performance capability specified in the regulations, 10 CFR 73.45. An overall measure of performance for each capability is the result of this aggregation process. This paper provides a descripton of SURE

  3. Comparison and evaluation of flexible and stiff piping systems

    International Nuclear Information System (INIS)

    Hahn, W.; Tang, H.T.; Tang, Y.K.

    1983-01-01

    An experimental and numerical study was performed on a piping system, with various support configurations, to assess the difference in piping response for flexible and stiff piping systems. Questions have arisen concerning a basic design philosophy employed in present day piping designs. One basic question is, the reliability of a flexible piping system greater than that of a stiff piping system by virtue of the fact that a flexible system has fewer snubber supports. With fewer snubbers, the pipe is less susceptible to inadvertent thermal stresses introduced by snubber malfunction during normal operation. In addition to the technical issue, the matter of cost savings in flexible piping system design is a significant one. The costs associated with construction, in-service inspection and maintenance are all significantly reduced by reducing the number of snubber supports. The evaluation study, sponsored by the Electric Power Research Institute, was performed on a boiler feedwater line at Consolidated Edison's Indian Point Unit 1. In this study, the boiler feedwater line was tested and analyzed with two fundamentally different support systems. The first system was very flexible, employing rod and spring hangers, and represented the 'old' design philosophy. The pipe system was very flexible with this support system, due to the long pipe span lengths between supports and the fact that there was only one lateral support. This support did not provide much restraint since it was near an anchor. The second system employed strut and snubber supports and represented the 'modern' design philosophy. The pipe system was relatively stiff with this support system, primarily due to the increased number of supports, including lateral supports, thereby reducing the pipe span lengths between supports. The second support system was designed with removable supports to facilitate interchange of the supports with different support types (i.e., struts, mechanical snubbers and hydraulic

  4. Cooperative Telerobotic Retrieval system Phase 1 technology evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, R.A.; Croft, K.M.

    1995-03-01

    This document describes the results from the Cooperative Telerobotic Retrieval demonstration and testing conducted at the Idaho National Engineering Laboratory during December 1994 and January 1995. The purpose of the demonstration was to ascertain the feasibility of the system for deploying tools both independently and cooperatively for supporting remote characterization and removal of buried waste in a safe manner and in compliance with all regulatory requirements. The procedures and goals of the demonstration were previously defined in the Cooperative Telerobotic Retrieval System Test Plan for Fiscal Year 1994, which served as a guideline for evaluating the system.

  5. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  6. Solar energy system economic evaluation: Fern Tunkhannock, Tunkhannock, Pennsylvania

    Science.gov (United States)

    1980-01-01

    The economic performance of an Operational Test Site (OTS) is described. The long term economic performance of the system at its installation site and extrapolation to four additional selected locations to demonstrate the viability of the design over a broad range of environmental and economic conditions is reported. Topics discussed are: system description, study approach, economic analysis and system optimization, and technical and economical results of analysis. Data for the economic analysis are generated through evaluation of the OTS. The simulation is based on the technical results of the seasonal report simulation. In addition localized and standard economic parameters are used for economic analysis.

  7. Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS)

    Energy Technology Data Exchange (ETDEWEB)

    Bland, Geoffrey [NASA Goddard Space Flight Center (GSFC), Greenbelt, MD (United States)

    2016-06-30

    The use of small unmanned aircraft systems (sUAS) with miniature sensor systems for atmospheric research is an important capability to develop. The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) project, lead by Dr. Gijs de Boer of the Cooperative Institute for Research in Environmental Sciences (CIRES- a partnership of NOAA and CU-Boulder), is a significant milestone in realizing this new potential. This project has clearly demonstrated that the concept of sUAS utilization is valid, and miniature instrumentation can be used to further our understanding of the atmospheric boundary layer in the arctic.

  8. NASA Lewis Evaluation of Regenerative Fuel Cell (RFC) Systems

    Science.gov (United States)

    Hagedorn, N. H.; Gonzalez-Sanabria, O. D; Kohout, L. L.

    1986-01-01

    Evaluation of two regenerative fuel cell (RFC) systems was begun in-house, and under contracts and grants. The passive hydrogen-oxygen RFC offers the possibility of a high-energy density, long-life storage system for geosynchronous Earth orbit missions. The hydrogen-bromine RFC offers the combination of high efficiency and moderate energy density that could ideally suit low Earth orbit missions if successfully developed. Either or both of these systems would be attractive additions to the storage options available to designers of future missions.

  9. Comparison of heuristic and cognitive walkthrough usability evaluation methods for evaluating health information systems.

    Science.gov (United States)

    Khajouei, Reza; Zahiri Esfahani, Misagh; Jahani, Yunes

    2017-04-01

    There are several user-based and expert-based usability evaluation methods that may perform differently according to the context in which they are used. The objective of this study was to compare 2 expert-based methods, heuristic evaluation (HE) and cognitive walkthrough (CW), for evaluating usability of health care information systems. Five evaluators independently evaluated a medical office management system using HE and CW. We compared the 2 methods in terms of the number of identified usability problems, their severity, and the coverage of each method. In total, 156 problems were identified using the 2 methods. HE identified a significantly higher number of problems related to the "satisfaction" attribute ( P  = .002). The number of problems identified using CW concerning the "learnability" attribute was significantly higher than those identified using HE ( P  = .005). There was no significant difference between the number of problems identified by HE, based on different usability attributes ( P  = .232). Results of CW showed a significant difference between the number of problems related to usability attributes ( P  systems intended for novice users and HE for users who have experience with similar systems. However, more studies are needed to support this finding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  10. Volatile Organic Compounds Identified in Post-Flight Air Analysis of the Multipurpose Logistics Module from International Space Station

    Science.gov (United States)

    Peterson, B.; Wheeler, R.

    Bioregenerative systems involve storing and processing waste along with atmospheric management. The MPLM, Multipurpose Logistics Module, is a reusable logistics carrier and primary delivery system used to resupply the International Space Station (ISS) and return Station cargo that requires a pressurized environment. The cylindrical module is approximately 6.4 meters long, 4.6 meters in diameter, and weighs almost 4,082kg. The module provides storage and additional workspace for up to two astronauts when docked to the ISS. It can carry up to 9,072 kg of supplies, science experiments, spare parts and other logistical components for ISS. There is concern for a potentially hazardous condition caused by contamination of the atmosphere in the MPLM upon return from orbit. This would be largely due to unforeseen spills or container leakage. This has led to the need for special care in handling the returned module prior to processing the module for its next flight. Prior to opening the MPLM, atmospheric samples are analyzed for trace volatile organic compounds, VOC's. It is noted that our analyses also reflect the atmosphere in the ISS on that day of closure. With the re turn of STS-108, 12th ISS Flight (UF1), the analysis showed 24 PPM of methane. This corresponds to the high levels on space station during a time period when the air filtration system was shut off. Chemical characterization of atmospheres on the ISS and MPLM provide useful information for concerns with plant growth experiments on ISS. Work with closed plant growth chambers show potential for VOC's to accumulate to toxic levels for plants. The ethylene levels for 4 MPLM analyses over the course on one year were measured at, 0.070, 0.017, 0.012 and 0.007 PPM. Phytochemical such as ethylene are detected with natural plant physiological events such as flowering and as a result of plant damage or from decaying food. A build up of VOC's may contribute to phytotoxic effects for the plant growth experiments or

  11. Evaluating a decision making system for cardiovascular dysautonomias diagnosis.

    Science.gov (United States)

    Idri, Ali; Kadi, Ilham

    2016-01-01

    Autonomic nervous system (ANS) is the part of the nervous system that is involved in homeostasis of the whole body functions. A malfunction in this system can lead to a cardiovascular dysautonomias. Hence, a set of dynamic tests are adopted in ANS units to diagnose and treat patients with cardiovascular dysautonomias. The purpose of this study is to develop and evaluate a decision tree based cardiovascular dysautonomias prediction system on a dataset collected from the ANS unit of the Moroccan university hospital Avicenne. We collected a dataset of 263 records from the ANS unit of the Avicenne hospital. This dataset was split into three subsets: training set (123 records), test set (55 records) and validation set (85 records). C4.5 decision tree algorithm was used in this study to develop the prediction system. Moreover, Java Enterprise Edition platform was used to implement a prototype of the developed system which was deployed in the Avicenne ANS unit so as to be clinically validated. The performance of the decision tree-based prediction system was evaluated by means of the error rate criterion. The error rates were measured for each classifier and have achieved an average value of 1.46, 2.24 and 0.89 % in training, test, and validation sets respectively. The results obtained were encouraging but further replicated studies are still needed to be performed in order to confirm the findings of this study.

  12. Reliability evaluation of deregulated electric power systems for planning applications

    International Nuclear Information System (INIS)

    Ehsani, A.; Ranjbar, A.M.; Jafari, A.; Fotuhi-Firuzabad, M.

    2008-01-01

    In a deregulated electric power utility industry in which a competitive electricity market can influence system reliability, market risks cannot be ignored. This paper (1) proposes an analytical probabilistic model for reliability evaluation of competitive electricity markets and (2) develops a methodology for incorporating the market reliability problem into HLII reliability studies. A Markov state space diagram is employed to evaluate the market reliability. Since the market is a continuously operated system, the concept of absorbing states is applied to it in order to evaluate the reliability. The market states are identified by using market performance indices and the transition rates are calculated by using historical data. The key point in the proposed method is the concept that the reliability level of a restructured electric power system can be calculated using the availability of the composite power system (HLII) and the reliability of the electricity market. Two case studies are carried out over Roy Billinton Test System (RBTS) to illustrate interesting features of the proposed methodology

  13. Evaluation of energy system analysis techniques for identifying underground facilities

    Energy Technology Data Exchange (ETDEWEB)

    VanKuiken, J.C.; Kavicky, J.A.; Portante, E.C. [and others

    1996-03-01

    This report describes the results of a study to determine the feasibility and potential usefulness of applying energy system analysis techniques to help detect and characterize underground facilities that could be used for clandestine activities. Four off-the-shelf energy system modeling tools were considered: (1) ENPEP (Energy and Power Evaluation Program) - a total energy system supply/demand model, (2) ICARUS (Investigation of Costs and Reliability in Utility Systems) - an electric utility system dispatching (or production cost and reliability) model, (3) SMN (Spot Market Network) - an aggregate electric power transmission network model, and (4) PECO/LF (Philadelphia Electric Company/Load Flow) - a detailed electricity load flow model. For the purposes of most of this work, underground facilities were assumed to consume about 500 kW to 3 MW of electricity. For some of the work, facilities as large as 10-20 MW were considered. The analysis of each model was conducted in three stages: data evaluation, base-case analysis, and comparative case analysis. For ENPEP and ICARUS, open source data from Pakistan were used for the evaluations. For SMN and PECO/LF, the country data were not readily available, so data for the state of Arizona were used to test the general concept.

  14. Evaluation of Robotic Systems to Carry Out Traverse Execution, Opportunistic Science, and Landing Site Evaluation Tasks

    Science.gov (United States)

    Hoffman, Stephen J.; Leonard, Matther J.; Pacal, Lee

    2011-01-01

    This report covers the execution of and results from the activities proposed and approved in Exploration Analogs and Mission Development (EAMD) Field Test Protocol HMP2010: Evaluation of Robotic Systems to carry out Traverse Execution, Opportunistic Science, and Landing Site Evaluation Tasks. The field tests documented in this report examine one facet of a larger program of planetary surface exploration. This program has been evolving and maturing for several years, growing from a broad policy statement with a few specified milestones for NASA to an international effort with much higher fidelity descriptions of systems and operations necessary to accomplish this type of exploration.

  15. The evaluation of set of criticality parameters using scale system

    International Nuclear Information System (INIS)

    Abe, Alfredo; Sanchez, Andrea; Yamaguchi, Mistuo

    2009-01-01

    In evaluating the criticality safety of the nuclear fuel facility, it is important to apply a consistent methodology, which consider every aspects concerning various types of criticality parameters. Usually, the critical parameters are compiled and arranged into handbooks, and these handbooks are based on experience with nuclear facilities, experimental data from criticality safety research facilities, and theoretical studies performed using numerical simulations. Most of criticality safety evaluation can be addressed using the criticality parameters data directly from handbook, but some critical parameters for a specific chemical mixtures and/or enrichment are not be available. Consequently, not available parameters has to be evaluated. This work present the methodology to evaluate a set of critical parameters using SCALE system for various types of mixtures present at nuclear fuel cycle facilities for two different level of enrichment, the results are verified in the independent calculation using MCNP Monte Carlo Code. (author)

  16. Tabletop exercise as a tool of evaluating physical protection system

    International Nuclear Information System (INIS)

    Matsuzawa, Reina

    2014-01-01

    Evaluation of designed and implemented physical protection system (PPS) is essential for ensuring the effectiveness of PPS. In Japan, nuclear facility operators, which are required to assess performance of PPS, have conducted performance test of PPS element and periodical trainings as well as annual PPS exercise with relevant agencies. In addition to these practical or field efforts, non-field tool for evaluating PPS effectiveness such as tabletop exercise (TTX) can be utilized as it is applied in the USA and other countries. This paper discusses the potential advantage of TTX as an evaluation tool of PPS effectiveness, looking at the characterizations of TTX in comparison to field evaluations, and potential cases where operator would get benefit from TTX especially. (author)

  17. Performance evaluation and design of flight vehicle control systems

    CERN Document Server

    Falangas, Eric T

    2015-01-01

    This book will help students, control engineers and flight dynamics analysts to model and conduct sophisticated and systemic analyses of early flight vehicle designs controlled with multiple types of effectors and to design and evaluate new vehicle concepts in terms of satisfying mission and performance goals. Performance Evaluation and Design of Flight Vehicle Control Systems begins by creating a dynamic model of a generic flight vehicle that includes a range of elements from airplanes and launch vehicles to re-entry vehicles and spacecraft. The models may include dynamic effects dealing with structural flexibility, as well as dynamic coupling between structures and actuators, propellant sloshing, and aeroelasticity, and they are typically used for control analysis and design. The book shows how to efficiently combine different types of effectors together, such as aero-surfaces, TVC, throttling engines and RCS, to operate as a system by developing a mixing logic atrix. Methods of trimming a vehicle controll...

  18. Performance Evaluation of Data Compression Systems Applied to Satellite Imagery

    Directory of Open Access Journals (Sweden)

    Lilian N. Faria

    2012-01-01

    Full Text Available Onboard image compression systems reduce the data storage and downlink bandwidth requirements in space missions. This paper presents an overview and evaluation of some compression algorithms suitable for remote sensing applications. Prediction-based compression systems, such as DPCM and JPEG-LS, and transform-based compression systems, such as CCSDS-IDC and JPEG-XR, were tested over twenty multispectral (5-band images from CCD optical sensor of the CBERS-2B satellite. Performance evaluation of these algorithms was conducted using both quantitative rate-distortion measurements and subjective image quality analysis. The PSNR, MSSIM, and compression ratio results plotted in charts and the SSIM maps are used for comparison of quantitative performance. Broadly speaking, the lossless JPEG-LS outperforms other lossless compression schemes, and, for lossy compression, JPEG-XR can provide lower bit rate and better tradeoff between compression ratio and image quality.

  19. Performance management in the Slovak higher education system: preliminary evaluation

    Directory of Open Access Journals (Sweden)

    Juraj Nemec

    2007-10-01

    Full Text Available The aim of our paper is a preliminary evaluation of the introduction of performance management and performance financing arrangements in the Slovak higher education system – accreditation and formula based performance financing. This evaluation will be mainly based on the assessment of short-term impacts of the above mentioned instruments and is expected to invite further professional discussion. We feel that the data and brief analysis included are sufficient enough to show that the Slovak system represents a typical example of the potential of performance management and performance financing being significantly limited, if not destroyed. Not only because of improperly defined indicators, which are too much input and quantity orientated, but very much also due to a lack of resources (the ratio of public expenditures for higher education to the GDP in Slovakia is significantly below EU average, as well as the politicization of the system.

  20. Design Optimization and Evaluation of Different Wind Generator Systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Li, Hui

    2008-01-01

    With rapid development of wind power technologies and significant growth of wind power capacity installed worldwide, various wind generator systems have been developed and built. The objective of this paper is to evaluate various wind generator systems by optimization designs and comparisons...... and power electronic converter are presented; design optimizations of the investigated wind generator systems are developed with an improved genetic algorithm. Next, the optimization designs are implemented of various wind generator systems at 0.75-MW, 1.5-MW, 3.0-MW, 5.0-MWand 10MW, respectively....... In this paper, seven variable speed constant frequency (VSCF) wind generator systems are investigated, namely permanent magnet synchronous generators with the direct-driven (PMSG_DD), the single-stage gearbox (PMSG_1G) and three-stage gearbox (PMSG_3G) concepts, doubly fed induction generators with the three...

  1. Evaluation of the reliability of a passive system

    International Nuclear Information System (INIS)

    Bianchi, F.; Burgazzi, L.; D'Auria, F.; Galassi, G.M.; Ricotti, M.E.; Oriani, L.

    2001-01-01

    A passive system should be theoretically more reliable than an active one. In fact its operation is independent by any external input or energy and is relied only upon natural physical laws (e.g., gravity, natural circulation, etc.) and/or 'intelligent' use of the energy inherently available in the system (e.g., chemical reaction, decay heat, etc.). Nevertheless the passive system may fail its mission as consequences of component failures, deviation of physical phenomena, boundary and/or initial conditions from the expectation. This document describes at first the methodology developed by ENEA, in collaboration of University of Pisa and Polytechnic of Milano, allowing the evaluation of the reliability for a passive system, which operation is based on moving working fluids (type B and C, cf. IAEA). It reports the results of an exercise performed on a system, which operation is based on Natural Circulation.(author)

  2. Development of a Technical Library to Support Computer Systems Evaluation

    Directory of Open Access Journals (Sweden)

    Patricia Munson Malley

    1971-12-01

    Full Text Available This paper reports on the development and growth of the United States Army Computer Systems Support and Evaluation Command (USACSSEC Technical Reference Library from a collection of miscellaneous documents related to only fifty computer systems to the present collection of approximately 10,000 hardware/software technical documents related to over 200 systems from 70 manufacturers. Special emphasis is given to the evolution of the filing system and retrieval techniques unique to the USACSSEC Technical Reference Library, i.e., computer listings of available documents in various sequences, and development uf the cataloging system adaptable to computer technology. It is hoped that this paper will be a contribution toward a standard approach in cataloging ADP collections.

  3. Solar energy system economic evaluation for Seeco Lincoln, Lincoln, Nebraska

    Science.gov (United States)

    1980-01-01

    The economic analysis of the solar energy system that was installed at Lincoln, Nebraska is developed for this and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over projected twenty year life: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  4. Solar energy system economic evaluation for Solaron Akron, Akron, Ohio

    Science.gov (United States)

    1980-01-01

    The economic analysis of the solar energy system that was installed at Akron, Ohio is developed for this and four other sites typical of a wide range of environmental and economic conditions. The analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results show that only in Albuquerque, New Mexico, where insolation is 1828 Btu/sq ft/day and the conventional energy cost is high, is this solar energy system marginally profitable.

  5. Evaluation of PLC systems for smart metering; Evaluation von PLC-Uebertragungssystemen fuer Smart Metering

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Michael; Sigle, Martin; Dostert, Klaus [KIT, Karlsruhe (Germany). Inst. fuer Industrielle Informationstechnik

    2010-07-01

    Information and communication technologies are the basis for implementing Smart Grids. Currently, there is great demand for communications solutions that allow for interconnecting smart energy meters in particular. The users' interests focus on Power Line Communication due to economic considerations. Despite a large and even growing number of PLC-based data transmission technology, however, only few reliable information about the system performance is available to potential users. As a first step, it is therefore necessary to identify the actually achievable system performance of different communication systems. In this article, we describe two approaches for evaluating the performance of PLC systems taking into account the unique physical properties of the transmission channel. In addition, we present evaluation results that provide a basis for a realistic assessment of the potential of communication technology based on PLC. (orig.)

  6. Electronic clinical safety reporting system: a benefits evaluation.

    Science.gov (United States)

    Elliott, Pamela; Martin, Desmond; Neville, Doreen

    2014-06-11

    Eastern Health, a large health care organization in Newfoundland and Labrador (NL), started a staged implementation of an electronic occurrence reporting system (used interchangeably with "clinical safety reporting system") in 2008, completing Phase One in 2009. The electronic clinical safety reporting system (CSRS) was designed to replace a paper-based system. The CSRS involves reporting on occurrences such as falls, safety/security issues, medication errors, treatment and procedural mishaps, medical equipment malfunctions, and close calls. The electronic system was purchased from a vendor in the United Kingdom that had implemented the system in the United Kingdom and other places, such as British Columbia. The main objective of the new system was to improve the reporting process with the goal of improving clinical safety. The project was funded jointly by Eastern Health and Canada Health Infoway. The objectives of the evaluation were to: (1) assess the CSRS on achieving its stated objectives (particularly, the benefits realized and lessons learned), and (2) identify contributions, if any, that can be made to the emerging field of electronic clinical safety reporting. The evaluation involved mixed methods, including extensive stakeholder participation, pre/post comparative study design, and triangulation of data where possible. The data were collected from several sources, such as project documentation, occurrence reporting records, stakeholder workshops, surveys, focus groups, and key informant interviews. The findings provided evidence that frontline staff and managers support the CSRS, identifying both benefits and areas for improvement. Many benefits were realized, such as increases in the number of occurrences reported, in occurrences reported within 48 hours, in occurrences reported by staff other than registered nurses, in close calls reported, and improved timelines for notification. There was also user satisfaction with the tool regarding ease of use

  7. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    Science.gov (United States)

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  8. Satellite power system concept development and evaluation program system definition technical assessment report

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-01

    The results of the system definition studies conducted by NASA as a part of the Department of Energy/National Aeronautics and Space Administration SPS Concept Development and Evaluation Program are summarized. The purpose of the system definition efforts was to identify and define candidate SPS concepts and to evaluate the concepts in terms of technical and cost factors. Although the system definition efforts consisted primarily of evaluation and assessment of alternative technical approaches, a reference system was also defined to facilitate economic, environmental, and societal assessments by the Department of Energy. This reference system was designed to deliver 5 GW of electrical power to the utility grid. Topics covered include system definition; energy conversion and power management; power transmission and reception; structures, controls, and materials; construction and operations; and space transportation.

  9. Body surface posture evaluation: construction, validation and protocol of the SPGAP system (Posture evaluation rotating platform system).

    Science.gov (United States)

    Schwertner, Debora Soccal; Oliveira, Raul; Mazo, Giovana Zarpellon; Gioda, Fabiane Rosa; Kelber, Christian Roberto; Swarowsky, Alessandra

    2016-05-04

    Several posture evaluation devices have been used to detect deviations of the vertebral column. However it has been observed that the instruments present measurement errors related to the equipment, environment or measurement protocol. This study aimed to build, validate, analyze the reliability and describe a measurement protocol for the use of the Posture Evaluation Rotating Platform System (SPGAP, Brazilian abbreviation). The posture evaluation system comprises a Posture Evaluation Rotating Platform, video camera, calibration support and measurement software. Two pilot studies were carried out with 102 elderly individuals (average age 69 years old, SD = ±7.3) to establish a protocol for SPGAP, controlling the measurement errors related to the environment, equipment and the person under evaluation. Content validation was completed with input from judges with expertise in posture measurement. The variation coefficient method was used to validate the measurement by the instrument of an object with known dimensions. Finally, reliability was established using repeated measurements of the known object. Expert content judges gave the system excellent ratings for content validity (mean 9.4 out of 10; SD 1.13). The measurement of an object with known dimensions indicated excellent validity (all measurement errors posture with applicability and clinical use, since it managed to reduce several measurement errors, amongst which parallax distortion.

  10. Safety Evaluation of Kartini Reactor Based on Instrumentation System Design

    International Nuclear Information System (INIS)

    Tjipta Suhaemi; Djen Djen Dj; Itjeu K; Johnny S; Setyono

    2003-01-01

    The safety of Kartini reactor has been evaluated based on instrumentation system aspect. The Kartini reactor is designed by BATAN. Design power of the reactor is 250 kW, but it is currently operated at 100 kW. Instrumentation and control system function is to monitor and control the reactor operation. Instrumentation and control system consists of safety system, start-up and automatic power control, and process information system. The linear power channel and logarithmic power channel are used for measuring power. There are 3 types of control rod for controlling the power, i.e. safety rod, shim rod, and regulating rod. The trip and interlock system are used for safety. There are instrumentation equipment used for measuring radiation exposure, flow rate, temperature and conductivity of fluid The system of Kartini reactor has been developed by introducing a process information system, start-up system, and automatic power control. It is concluded that the instrumentation of Kartini reactor has followed the requirement and standard of IAEA. (author)

  11. A new automatic system for Cytomegalovirus antibodies screening: preliminary evaluation

    Directory of Open Access Journals (Sweden)

    Anna De Angelis

    2008-12-01

    Full Text Available The aim of our study was to evaluate the automated enhanced-chemiluminescence VITROS EciQ (Ortho system compared to the EIA ALISEI (Radim system for the first level detection of CMV IgG and IgM antibodies. Samples derived from 95 immunocompetent patients were examined. Both systems showed similar results for CMV IgG: 63 samples were positive, 28 negative and 4 samples were weakly positive. The four weakly positive samples were subsequently confirmed with the LIAISON (DiaSorin system. Agreement was 91% concerning CMV IgM detection: 79 samples were negative, 7 positive and 9 samples releved discrepancy between the two systems.When these 9 cases were tested with LIAISON system for CMV IgM and IgG and the CMV IgG avidity test, data revealed complete agreement between VITROS EciQ and LIAISON systems.VITROS EciQ system seems to be a valuable system for the first level diagnosis of CMV infection.

  12. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  13. [Assessment of an Evaluation System for Psychiatry Learning].

    Science.gov (United States)

    Campo-Cabal, Gerardo

    2012-01-01

    Through the analysis of a teaching evaluation system for a Psychiatry course aimed at Medicine students, the author reviews the basic elements taken into account in a teaching assessment process. Analysis was carried out of the assessment methods used as well as of the grades obtained by the students from four groups into which the they were divided. The selected assessment methods are appropriate to evaluate educational objectives; the contents are selected by means of a specification matrix; there is a high correlation coefficient between the grades obtained in previous academic periods and the ones obtained in the course, thus demonstrating the validity of the results (both considering the whole exam or just a part of it). Most of the students are on the right side of the grading curve, which means that the majority of them acquire the knowledge expected. The assessment system used in the Psychopathology course is fair, valid and reliable, specifically concerning the objective methods used, but the conceptual evaluation should be improved or, preferably, eliminated as a constituernt part of the evaluation system. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  14. Evaluation of Life Cycle Assessment (LCA) for Roadway Drainage Systems.

    Science.gov (United States)

    Byrne, Diana M; Grabowski, Marta K; Benitez, Amy C B; Schmidt, Arthur R; Guest, Jeremy S

    2017-08-15

    Roadway drainage design has traditionally focused on cost-effectively managing water quantity; however, runoff carries pollutants, posing risks to the local environment and public health. Additionally, construction and maintenance incur costs and contribute to global environmental impacts. While life cycle assessment (LCA) can potentially capture local and global environmental impacts of roadway drainage and other stormwater systems, LCA methodology must be evaluated because stormwater systems differ from wastewater and drinking water systems to which LCA is more frequently applied. To this end, this research developed a comprehensive model linking roadway drainage design parameters to LCA and life cycle costing (LCC) under uncertainty. This framework was applied to 10 highway drainage projects to evaluate LCA methodological choices by characterizing environmental and economic impacts of drainage projects and individual components (basin, bioswale, culvert, grass swale, storm sewer, and pipe underdrain). The relative impacts of drainage components varied based on functional unit choice. LCA inventory cutoff criteria evaluation showed the potential for cost-based criteria, which performed better than mass-based criteria. Finally, the local aquatic benefits of grass swales and bioswales offset global environmental impacts for four impact categories, highlighting the need to explicitly consider local impacts (i.e., direct emissions) when evaluating drainage technologies.

  15. Evaluation System and Implementation Countermeasure of Automobile Green Maintenance

    Science.gov (United States)

    Zhang, Fei; Xie, Xinxin; Yan, Chaoyong

    2018-01-01

    Green maintenance research is in the beginning of our country, the work is being explored. Based on the existing research results at home and abroad, this paper learns and draws lessons from the experiences and lessons of foreign advanced countries and domestic advanced enterprises. In the face of the challenges brought by economic development and energy saving and emission reduction, this paper discusses the green maintenance theory and security system, And the research status of green maintenance content and system at home and abroad, through the deletion and selection of green maintenance index, through the AHP method to determine the green evaluation criteria, and the introduction of C equivalent evaluation system, the use of fuzzy synthesis Evaluation method to build a green maintenance evaluation model, and the actual validation, put forward the implementation of green maintenance feasibility programs and related security recommendations, vehicle maintenance enterprises to carry out green maintenance, improve business efficiency and reduce environmental management costs to provide theoretical basis. And to achieve effective reduction of environmental pollution, reduce maintenance costs of the target, a reasonable promotion of maintenance and environmental protection and sustainable development. Promote green maintenance from research to practice, from the laboratory to the maintenance of enterprises, from the pilot to the overall development and transformation.

  16. Cross-system evaluation of clinical trial search engines.

    Science.gov (United States)

    Jiang, Silis Y; Weng, Chunhua

    2014-01-01

    Clinical trials are fundamental to the advancement of medicine but constantly face recruitment difficulties. Various clinical trial search engines have been designed to help health consumers identify trials for which they may be eligible. Unfortunately, knowledge of the usefulness and usability of their designs remains scarce. In this study, we used mixed methods, including time-motion analysis, think-aloud protocol, and survey, to evaluate five popular clinical trial search engines with 11 users. Differences in user preferences and time spent on each system were observed and correlated with user characteristics. In general, searching for applicable trials using these systems is a cognitively demanding task. Our results show that user perceptions of these systems are multifactorial. The survey indicated eTACTS being the generally preferred system, but this finding did not persist among all mixed methods. This study confirms the value of mixed-methods for a comprehensive system evaluation. Future system designers must be aware that different users groups expect different functionalities.

  17. Information Systems Evaluation: A Study in Hospital Organizations

    Directory of Open Access Journals (Sweden)

    Laís Coelho Ayala

    2012-06-01

    Full Text Available Given increasing demand for timely and accurate information to support decision making, hospitals, a particularly complex type of service organization, have increasingly resorted to a wide range of tools such as the Clinical Information Systems (CIS. However, research has shown that such systems do not always meet hospital managers’ needs, and assessment processes are necessary both before and after CIS implementation. Aiming to identify whether the CIS do meet hospital managers’ information needs and do fit in the specificities of such organizations, this paper reports on the assessment of four CIS based on the perspective of their users in four hospitals in the Metropolitan Region of Belo Horizonte, State of Minas Gerais, Brazil. The data was collected by means of semi-structured interviews and non-obtrusive observation. On the one hand, the result shows that the four organizations have difficulties in using their systems, such as accessibility problems, inadequate training and system underutilization. On the other hand, they also benefit from such systems, as they make processes faster and enable information control. One can say that the results from this research contribute to a better understanding of evaluating information systems in hospitals. Managers of such organizations can benefit from these results when seeking to evaluate and improve their information systens.

  18. Usability evaluation of in-housed developed ERP system

    Science.gov (United States)

    Faisal, Chaudhry Muhammad Nadeem; Shakeel Faridi, Muhammad; Javed, Zahid

    2011-10-01

    Enterprise Resource Planning systems are the combination of different business IS (Information System) applications that are designed according to the organization requirements. Generally ERP systems are suffering from complex user interface issues. Recent research shows that there is a need for improvement concerning, the user interface from their perspectives. In order to design the software applications that are easy to use, memorize and apply to new problems, we must know the users philosophy and something about learning, reminiscence and problems solving. The Usability engineering is the only way to study the deeds of users while interacting with ERP (Enterprise Resource & Planning). This paper will focus on the users' experiences view of financial module in ERP system. The HCI research method, explicitly survey questionnaire method was adopted to gather users understanding in order to evaluate the selected modules for in-housed ERP system. The study involved group of users from two industries, the results can not be generalized as a whole. The study was first time successfully applied Usability evaluation on in-housed ERP in local industry (Masood Textile Mills, Interloop Ltd) in Pakistan. The results may hopefully opened-up an area of research and methodology that could provide considerable further benefits to Industry in developments of Industrial information systems.

  19. An evaluation of the management system verification pilot at Hanford

    International Nuclear Information System (INIS)

    Briggs, C.R.; Ramonas, L.; Westendorf, W.

    1998-01-01

    The Chemical Management System (CMS), currently under development at Hanford, was used as the ''test program'' for pilot testing the value added aspects of the Chemical Manufacturers Association's (CMA) Management Systems Verification (MSV) process. The MSV process, which was developed by CMA's member chemical companies specifically as a tool to assist in the continuous improvement of environment, safety and health (ESH) performance, represents a commercial sector ''best practice'' for evaluating ESH management systems. The primary purpose of Hanford's MSV Pilot was to evaluate the applicability and utility of the MSV process in the Department of Energy (DOE) environment. However, because the Integrated Safety Management System (ISMS) is the framework for ESH management at Hanford and at all DOE sites, the pilot specifically considered the MSV process in the context of a possible future adjunct to Integrated Safety Management System Verification (ISMSV) efforts at Hanford and elsewhere within the DOE complex. The pilot involved the conduct of two-hour interviews with four separate panels of individuals with functional responsibilities related to the CMS including the Department of Energy Richland Operations (DOE-RL), Fluor Daniel Hanford (FDH) and FDH's major subcontractors (MSCS). A semi-structured interview process was employed by the team of three ''verifiers'' who directed open-ended questions to the panels regarding the development, integration and effectiveness of management systems necessary to ensure the sustainability of the CMS effort. An ''MSV Pilot Effectiveness Survey'' also was completed by each panel participant immediately following the interview

  20. The equity lens in the health care performance evaluation system.

    Science.gov (United States)

    Barsanti, Sara; Nuti, Sabina

    2014-01-01

    The main objective of this paper is to describe how indicators of the equity of access to health care according to socioeconomic conditions may be included in a performance evaluation system (PES) in the regional context level and in the planning and strategic control system of healthcare organisations. In particular, the paper investigates how the PES adopted, in the experience of the Tuscany region in Italy, indicators of vertical equity over time. Studies that testify inequality of access to health services often remain just a research output and are not used as targets and measurements in planning and control systems. After a brief introduction to the concept of horizontal and vertical equity in health care systems and equity measures in PES, the paper describes the 'equity process' by which selected health indicators declined by socioeconomic conditions were shared and used in the evaluation of health care institutions and in the CEOs' rewarding system, and subsequently analyses the initial results. Results on the maternal and child path and the chronicity care path not only show improvements in addressing health care inequalities, but also verify whether the health system responds appropriately to different population groups. Copyright © 2013 John Wiley & Sons, Ltd.

  1. EVA Metro Sedan electric-propulsion system: test and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Reimers, E.

    1979-09-01

    The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on the dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.

  2. Evaluation of diurnal thermal energy storage combined with cogeneration systems

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaram, S.; Brown, D.R.; Drost, M.K.

    1992-11-01

    This report describes the results of an evaluation of thermal energy storage (TES) integrated with simple gas turbine cogeneration systems. The TES system captures and stores thermal energy from the gas turbine exhaust for immediate or future generation of process heat. Integrating thermal energy storage with conventional cogeneration equipment increases the initial cost of the combined system; but, by decoupling electric power and process heat production, the system offers the following two significant advantages: (1) Electric power can be generated on demand, irrespective of the process heat load profile, thus increasing the value of the power produced; (2) Although supplementary firing could be used to serve independently varying electric and process heat loads, this approach is inefficient. Integrating TES with cogeneration can serve the two independent loads while firing all fuel in the gas turbine. The study evaluated the cost of power produced by cogeneration and cogeneration/TES systems designed to serve a fixed process steam load. The value of the process steam was set at the levelized cost estimated for the steam from a conventional stand-alone boiler. Power costs for combustion turbine and combined-cycle power plants were also calculated for comparison. The results indicated that peak power production costs for the cogeneration/TES systems were between 25% and 40% lower than peak power costs estimated for a combustion turbine and between 15% and 35% lower than peak power costs estimated for a combined-cycle plant. The ranges reflect differences in the daily power production schedule and process steam pressure/temperature assumptions for the cases evaluated. Further cost reductions may result from optimization of current cogeneration/TES system designs and improvement in TES technology through future research and development.

  3. Evaluation of diurnal thermal energy storage combined with cogeneration systems

    Science.gov (United States)

    Somasundaram, S.; Brown, D. R.; Drost, M. K.

    1992-11-01

    This report describes the results of an evaluation of thermal energy storage (TES) integrated with simple gas turbine cogeneration systems. The TES system captures and stores thermal energy from the gas turbine exhaust for immediate or future generation of process heat. Integrating thermal energy storage with conventional cogeneration equipment increases the initial cost of the combined system; but, by decoupling electric power and process heat production, the system offers the following significant advantages: (1) electric power can be generated on demand, irrespective of the process heat load profile, thus increasing the value of the power produced; (2) although supplementary firing could be used to serve independently varying electric and process heat loads, this approach is inefficient. Integrating TES with cogeneration can serve the two independent loads while firing all fuel in the gas turbine. The study evaluated the cost of power produced by cogeneration and cogeneration/TES systems designed to serve a fixed process steam load. The value of the process steam was set at the levelized cost estimated for the steam from a conventional stand-alone boiler. Power costs for combustion turbine and combined-cycle power plants were also calculated for comparison. The results indicated that peak power production costs for the cogeneration/TES systems were between 25 and 40 percent lower than peak power costs estimated for a combustion turbine and between 15 and 35 percent lower than peak power costs estimated for a combined-cycle plant. The ranges reflect differences in the daily power production schedule and process steam pressure/temperature assumptions for the cases evaluated. Further cost reductions may result from optimization of current cogeneration/TES system designs and improvement in TES technology through future research and development.

  4. An Evaluation System for the Online Training Programs in Meteorology and Hydrology

    Science.gov (United States)

    Wang, Yong; Zhi, Xiefei

    2009-01-01

    This paper studies the current evaluation system for the online training program in meteorology and hydrology. CIPP model that includes context evaluation, input evaluation, process evaluation and product evaluation differs from Kirkpatrick model including reactions evaluation, learning evaluation, transfer evaluation and results evaluation in…

  5. Sustainable Deforestation Evaluation Model and System Dynamics Analysis

    Directory of Open Access Journals (Sweden)

    Huirong Feng

    2014-01-01

    Full Text Available The current study used the improved fuzzy analytic hierarchy process to construct a sustainable deforestation development evaluation system and evaluation model, which has refined a diversified system to evaluate the theory of sustainable deforestation development. Leveraging the visual image of the system dynamics causal and power flow diagram, we illustrated here that sustainable forestry development is a complex system that encompasses the interaction and dynamic development of ecology, economy, and society and has reflected the time dynamic effect of sustainable forestry development from the three combined effects. We compared experimental programs to prove the direct and indirect impacts of the ecological, economic, and social effects of the corresponding deforest techniques and fully reflected the importance of developing scientific and rational ecological harvesting and transportation technologies. Experimental and theoretical results illustrated that light cableway skidding is an ecoskidding method that is beneficial for the sustainable development of resources, the environment, the economy, and society and forecasted the broad potential applications of light cableway skidding in timber production technology. Furthermore, we discussed the sustainable development countermeasures of forest ecosystems from the aspects of causality, interaction, and harmony.

  6. Gamma- scintigraphy in the evaluation of drug delivery systems

    International Nuclear Information System (INIS)

    Shahhosseini, S.; Beiki, D.; Eftekhari, M.

    2003-01-01

    Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical delivery systems, particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate radionuclide such as technetium-99m or indium-111 into the formulation or by addition of a non- radioactive isotope such as samarium-152 followed by neutron activation of the final product. Drug delivery systems can be tested in vitro using various techniques like dissolution rate. Since in vitro testing methods are not predictive of in vivo results, such systems should be evaluated in vivo using animal models, especially oral dosage forms. Altered gastrointestinal transit due to individual variation, physiologic factors, or the presence of food may influence bioavailability. Distribution or drug release may be premature or delayed in vivo. Similarly, altered deposition or clearance from other routes of administration such as nasal, ocular, or inhalation may explain drug absorption anomalies. Therefore, there is a growing tendency for new drug delivery systems to be tested, whenever possible, in human subjects in a so called phase 1 clinical evaluation. Gamma- scintigraphy combined with knowledge of physiological and dosage from design can help to identify some of these variables. the resulting insight can be used to accelerate the formulation development process and to ensure success in early clinical trials

  7. Evaluation of Supply Chain Management Systems Used in Civil Engineering

    Science.gov (United States)

    Tomczak, Michał; Rzepecki, Łukasz

    2017-10-01

    One of the most important factors which have an effect on the cost and time of the building process is the organization of physical resources and the information flow structure. Depending on how effective this system is, a building project may end with a success or a failure. Because of many conditions of the construction executing and different needs of the contractors, there are different Supply Chain Management (SCM) systems connected with supplying construction projects: single-stage, multi-stage or combined. The article presents a comparative analysis of construction SCM systems based on a modified fuzzy AHP. The modification of this method is based on the use of interval type-2 fuzzy sets to aggregate evaluation according to the idea proposed by Mikhailov. The use of such a model of group preferences of decision-makers, makes it possible to take into consideration both the linguistic imprecision of an evaluation and the small number of experts. The weight values of specific criteria and the final scale vector of considered variants are obtained during the analysis. This may give a recommendation to general contractors in construction projects about which evaluation criteria and supply systems are preferred.

  8. A multi-method approach to evaluate health information systems.

    Science.gov (United States)

    Yu, Ping

    2010-01-01

    Systematic evaluation of the introduction and impact of health information systems (HIS) is a challenging task. As the implementation is a dynamic process, with diverse issues emerge at various stages of system introduction, it is challenge to weigh the contribution of various factors and differentiate the critical ones. A conceptual framework will be helpful in guiding the evaluation effort; otherwise data collection may not be comprehensive and accurate. This may again lead to inadequate interpretation of the phenomena under study. Based on comprehensive literature research and own practice of evaluating health information systems, the author proposes a multimethod approach that incorporates both quantitative and qualitative measurement and centered around DeLone and McLean Information System Success Model. This approach aims to quantify the performance of HIS and its impact, and provide comprehensive and accurate explanations about the casual relationships of the different factors. This approach will provide decision makers with accurate and actionable information for improving the performance of the introduced HIS.

  9. Sustainable Deforestation Evaluation Model and System Dynamics Analysis

    Science.gov (United States)

    Feng, Huirong; Lim, C. W.; Chen, Liqun; Zhou, Xinnian; Zhou, Chengjun; Lin, Yi

    2014-01-01

    The current study used the improved fuzzy analytic hierarchy process to construct a sustainable deforestation development evaluation system and evaluation model, which has refined a diversified system to evaluate the theory of sustainable deforestation development. Leveraging the visual image of the system dynamics causal and power flow diagram, we illustrated here that sustainable forestry development is a complex system that encompasses the interaction and dynamic development of ecology, economy, and society and has reflected the time dynamic effect of sustainable forestry development from the three combined effects. We compared experimental programs to prove the direct and indirect impacts of the ecological, economic, and social effects of the corresponding deforest techniques and fully reflected the importance of developing scientific and rational ecological harvesting and transportation technologies. Experimental and theoretical results illustrated that light cableway skidding is an ecoskidding method that is beneficial for the sustainable development of resources, the environment, the economy, and society and forecasted the broad potential applications of light cableway skidding in timber production technology. Furthermore, we discussed the sustainable development countermeasures of forest ecosystems from the aspects of causality, interaction, and harmony. PMID:25254225

  10. Sustainable deforestation evaluation model and system dynamics analysis.

    Science.gov (United States)

    Feng, Huirong; Lim, C W; Chen, Liqun; Zhou, Xinnian; Zhou, Chengjun; Lin, Yi

    2014-01-01

    The current study used the improved fuzzy analytic hierarchy process to construct a sustainable deforestation development evaluation system and evaluation model, which has refined a diversified system to evaluate the theory of sustainable deforestation development. Leveraging the visual image of the system dynamics causal and power flow diagram, we illustrated here that sustainable forestry development is a complex system that encompasses the interaction and dynamic development of ecology, economy, and society and has reflected the time dynamic effect of sustainable forestry development from the three combined effects. We compared experimental programs to prove the direct and indirect impacts of the ecological, economic, and social effects of the corresponding deforest techniques and fully reflected the importance of developing scientific and rational ecological harvesting and transportation technologies. Experimental and theoretical results illustrated that light cableway skidding is an ecoskidding method that is beneficial for the sustainable development of resources, the environment, the economy, and society and forecasted the broad potential applications of light cableway skidding in timber production technology. Furthermore, we discussed the sustainable development countermeasures of forest ecosystems from the aspects of causality, interaction, and harmony.

  11. Evaluating a pressure-redistribution mattress replacement system.

    Science.gov (United States)

    Newton, Heather

    2014-11-01

    Pressure ulcer prevention is high on the quality agenda and provision of pressure-relieving equipment to meet patients' needs is an essential part of this process. This can be challenging in today's NHS and this article explores the evaluation process that supported the procurement of the AtmosAir™ 4000 pressure-redistributing mattress replacement system. Outcomes suggest that, when combined with a robust repositioning and skin assessment regime, the AtmosAir 4000 performed well and dynamic mattress usage was reduced. Further evaluation over a longer period of time will be undertaken in future.

  12. Risk evaluation system for facility safeguards and security planning

    International Nuclear Information System (INIS)

    Udell, C.J.; Carlson, R.L.

    1987-01-01

    The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planing assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily

  13. Scopus: A system for the evaluation of scientific journals

    Science.gov (United States)

    Guz, A. N.; Rushchitsky, J. J.

    2009-04-01

    The paper discusses the evaluation of scientific journals based on the Scopus database, information tools, and criteria. The SJR (SCImago Journal Rank) as the main criterion used by Scopus to evaluate scientific journals is considered. The Scopus and ISI systems are compared using information on the journal Prikladnaya Mekhanika ( International Applied Mechanics), a number of world-known journals on mechanics, and some journals on natural sciences issued by the National Academy of Sciences of Ukraine. Some comments and proposals are formulated. This paper may be considered as a follow up on papers published in Prikladnaya Mekhanika ( International Applied Mechanics) in 2005-2009

  14. Evaluating New York City's abortion reporting system: insights for public health data collection systems.

    Science.gov (United States)

    Toprani, Amita; Madsen, Ann; Das, Tara; Gambatese, Melissa; Greene, Carolyn; Begier, Elizabeth

    2014-01-01

    New York City (NYC) mandates reporting of all abortion procedures. These reports enable tracking of abortion incidence and underpin programs, policy, and research. Since January 2011, the majority of abortion facilities must report electronically. We conducted an evaluation of NYC's abortion reporting system and its transition to electronic reporting. We summarize the evaluation methodology and results and draw lessons relevant to other vital statistics and public health reporting systems. The evaluation followed Centers for Disease Control and Prevention guidelines for evaluating public health surveillance systems. We interviewed key stakeholders and conducted a data provider survey. In addition, we compared the system's abortion counts with external estimates and calculated the proportion of missing and invalid values for each variable on the report form. Finally, we assessed the process for changing the report form and estimated system costs. NYC Health Department's Bureau of Vital Statistics. Usefulness, simplicity, flexibility, data quality, acceptability, sensitivity, timeliness, and stability of the abortion reporting system. Ninety-five percent of abortion data providers considered abortion reporting important; 52% requested training regarding the report form. Thirty percent reported problems with electronic biometric fingerprint certification, and 18% reported problems with the electronic system's stability. Estimated system sensitivity was 88%. Of 17 variables, education and ancestry had more than 5% missing values in 2010. Changing the electronic reporting module was costly and time-consuming. System operating costs were estimated at $80 136 to $89 057 annually. The NYC abortion reporting system is sensitive and provides high-quality data, but opportunities for improvement include facilitating biometric certification, increasing electronic platform stability, and conducting ongoing outreach and training for data providers. This evaluation will help data

  15. Shuttle orbiter Ku-band radar/communications system design evaluation. Deliverable test equipment evaluation

    Science.gov (United States)

    Maronde, R. G.

    1980-07-01

    The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.

  16. Design and Evaluation of a Reconfigurable Manufacturing System

    DEFF Research Database (Denmark)

    Zhang, Shuai; Li, Yang; Bilberg, Arne

    2014-01-01

    In modern manufacturing industry, reconfigurable manufacturing system (RMS) is a promising concept in the research arena. A new RMS system structure has been recently designed by a large consumer goods manufacturer in Europe, aiming to improve its production efficiency. This article shows...... an exploratory research on the (re)configuration procedure and evaluation of the RMS philosophy based on the new RMS structure, which is part of the RMS research in University of Southern Denmark. Tecnomatix Plant Simulation is used for system analysis and optimization. Results from simulation show that the RMS...... implemented in this consumer goods manufacturer can be effectively (re)configured as part of the daily operations, and the configuration is analyzed by computer simulation before release. Flexibility can be increased considerably meanwhile the system can maintain an acceptable productivity....

  17. Performance evaluation of various cryogenic energy storage systems

    International Nuclear Information System (INIS)

    Abdo, Rodrigo F.; Pedro, Hugo T.C.; Koury, Ricardo N.N.; Machado, Luiz; Coimbra, Carlos F.M.; Porto, Matheus P.

    2015-01-01

    This work compares various CES (cryogenic energy storage) systems as possible candidates to store energy from renewable sources. Mitigating solar and wind power variability and its direct effect on local grid stability are already a substantial technological bottleneck for increasing market penetration of these technologies. In this context, CES systems represent low-cost solutions for variability that can be used to set critical power ramp rates. We investigate the different thermodynamic and engineering constraints that affect the design of CES systems, presenting theoretical simulations, indicating that optimization is also needed to improve the cryogenic plant performance. - Highlights: • We assessed the performance of cryogenic energy storage systems. • We re-evaluated the Linde–Hampson cycle proposed by Chen. • We proposed the Claude and Collins cycles as alternatives for the Linde–Hampson cycle. • We concluded that Claude cycle is the best alternative for the simulated conditions.

  18. Solar energy system economic evaluation: Contemporary Newman, Georgia

    Science.gov (United States)

    1980-01-01

    An economic evaluation of performance of the solar energy system (based on life cycle costs versus energy savings) for five cities considered to be representative of a broad range of environmental and economic conditions in the United States is discussed. The considered life cycle costs are: hardware, installation, maintenance, and operating costs for the solar unique components of the total system. The total system takes into consideration long term average environmental conditions, loads, fuel costs, and other economic factors applicable in each of five cities. Selection criteria are based on availability of long term weather data, heating degree days, cold water supply temperature, solar insolation, utility rates, market potential, and type of solar system.

  19. Acceptance testing and evaluation of TOPAZ II space power systems

    Science.gov (United States)

    Follis, Hoby D.; Schmidt, Glen; Ogloblin, Boris; Sinkevich, Valery G.

    1995-01-01

    The Thermionic System Evaluation Test (TSET) facility, part of the TOPAZ International Program, in Albuquerque, New Mexico is currently testing Russian TOPAZ II space power systems (Wold 1993). The TOPAZ International Program has received six TOPAZ II Space Nuclear power Reactors. Two of these reactors (Eh-43 and Eh-44) are considered ``flight quality.'' A considerable transfer of technology has occurred during the preparations for acceptance testing of the Eh-43 and Eh-44 TOPAZ II reactors. The Eh-43 and Eh-44 are new systems that have not undergone any testing and require the coolant loop and gas cavities to be filled. The new systems will undergo an acceptance process that ranges from receipt inspection to thermal vacuum testing. The knowledge we gain from these tests will help determine the use of this technology in future applications.

  20. Modeling and evaluation of information systems using coloured petri network

    Directory of Open Access Journals (Sweden)

    Ehsan Zamirpour

    2014-07-01

    Full Text Available Nowadays with the growth of organizations and their affiliates, the importance of information systems has increased. Functional and non-functional requirements of information systems in an organization are supported. There are literally several techniques to support the functional requirements in terms of software methodologies, but support for the second set of requirements has received little attention. Software Performance Engineering (SPE forum tries to address this issue by presenting software methodologies to support both types of requirements. In this paper, we present a formal model for the evaluation of system performance based on a pragmatic model. Because of supporting the concurrency concepts, petri net has a higher priority than queuing system. For mapping UML to colored Petri net diagram, we use an intermediate graph. The preliminary results indicate that the proposed model may save significant amount of computations.

  1. Evaluating Complex Healthcare Systems: A Critique of Four Approaches

    Directory of Open Access Journals (Sweden)

    Heather Boon

    2007-01-01

    Full Text Available The purpose of this paper is to bring clarity to the emerging conceptual and methodological literature that focuses on understanding and evaluating complex or ‘whole’ systems of healthcare. An international working group reviewed literature from interdisciplinary or interprofessional groups describing approaches to the evaluation of complex systems of healthcare. The following four key approaches were identified: a framework from the MRC (UK, whole systems research, whole medical systems research described by NCCAM (USA and a model from NAFKAM (Norway. Main areas of congruence include acknowledgment of the inherent complexity of many healthcare interventions and the need to find new ways to evaluate these; the need to describe and understand the components of complex interventions in context (as they are actually practiced; the necessity of using mixed methods including randomized clinical trials (RCTs (explanatory and pragmatic and qualitative approaches; the perceived benefits of a multidisciplinary team approach to research; and the understanding that methodological developments in this field can be applied to both complementary and alternative medicine (CAM as well as conventional therapies. In contrast, the approaches differ in the following ways: terminology used, the extent to which the approach attempts to be applicable to both CAM and conventional medical interventions; the prioritization of research questions (in order of what should be done first especially with respect to how the ‘definitive’ RCT fits into the process of assessing complex healthcare systems; and the need for a staged approach. There appears to be a growing international understanding of the need for a new perspective on assessing complex healthcare systems.

  2. System Life Cycle Evaluation(SM) (SLiCE): harmonizing water treatment systems with implementers' needs.

    Science.gov (United States)

    Goodman, Joseph; Caravati, Kevin; Foote, Andrew; Nelson, Molly; Woods, Emily

    2013-06-01

    One of the methods proposed to improve access to clean drinking water is the mobile packaged water treatment system (MPWTS). The lack of published system performance comparisons combined with the diversity of technology available and intended operating conditions make it difficult for stakeholders to choose the system best suited for their application. MPWTS are often deployed in emergency situations, making selection of the appropriate system crucial to avoiding wasted resources and loss of life. Measurable critical-to-quality characteristics (CTQs) and a system selection tool for MPWTS were developed by utilizing relevant literature, including field studies, and implementing and comparing seven different MPWTS. The proposed System Life Cycle Evaluation (SLiCE) method uses these CTQs to evaluate the diversity in system performance and harmonize relevant performance with stakeholder preference via a selection tool. Agencies and field workers can use SLiCE results to inform and drive decision-making. The evaluation and selection tool also serves as a catalyst for communicating system performance, common design flaws, and stakeholder needs to system manufacturers. The SLiCE framework can be adopted into other emerging system technologies to communicate system performance over the life cycle of use.

  3. Evaluation of automatic exposure control systems in computed tomography

    International Nuclear Information System (INIS)

    Reina, Thamiris Rosado

    2014-01-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  4. Programming system for rapid evaluation of coal deposits

    Directory of Open Access Journals (Sweden)

    Stanìk František

    2002-09-01

    Full Text Available Programming system for rapid evaluation of coal deposits (calculation of coal reserves based on data stored in coal deposit database including processing of textual and graphic outputs was elaborated. The nature of such outputs is based on conventional coal reserve calculations so that connection with coal reserve calculations made in the past is secured. Differences in particular coal deposits as well as in individual coal seams are respected in the system. Coal seams differ one from another in their development by variability of seam thickness and seam quality within coal deposit etc. In addition to this, coal deposits are disturbed by tectonic failures and deformations. The system of evaluation of coal deposits is based on development of planar models of particular seams where calculation blocks are created and coal reserves contained in them are determined. Subsequently coal reserves of particular seams and of the whole deposit are determined. Natural limitation of seam model is given by determined minimum seam thickness and maximum ash content (i.e. content of inorganic component in coal. Basic model is structured according to detected main tectonic lines into tectonic blocks. According to further geological factors (e.g. erosion and contractual boundaries (e.g. demarcations, the deposit is structured into smaller units - calculation blocks. The whole system operates in a maximum automated regime with minimum manual interventions into solving procedure. The system enables rapid alternative calculations of coal reserves according to varying limit values of basic calculation parameters.

  5. Development of methods for usability evaluations of EHR systems.

    Science.gov (United States)

    Lilholt, Lars H; Pedersen, Signe S; Madsen, Inge; Nielsen, Per H; Boye, Niels; Andersen, Stig K; Nøhr, Christian

    2006-01-01

    Developing electronic health record (EHR) systems in Denmark is an on going, iterative process, where also a maturation process for clinical use should be considered. Convincing methodology for collecting and incorporating in the soft- and hardware knowledge and robustness for the clinical environments is not on hand. A way to involve the clinicians in the development process is conducting usability evaluations. The complexity of the clinical use of the systems is difficult to transmit to a usability laboratory, and due to ethical issues a traditional field study can be impossible to carry out. The aim of this study has been to investigate how it is possible to identify usability problems in an EHR system by combining methods from laboratory tests and field studies. The methods selected for the test design are: the think aloud method, video and screen recording, debriefing, a scenario based on an authentic patient record, and testing on the normal production system. The reliability and validity of the results is increased due to the application of method- and data-triangulation. The results of the usability evaluation include problems in the categories: system response time, GUI-design, functionality, procedures, and error messages. The problems were classified as cosmetic, severe, or critical according to a rating scale. The experience with each method is discussed. It is concluded that combining methods from laboratory test and field study makes it possible to identify usability problems. There are indications that some of the usability problems only occurred due to the establishment of an authentic scenario.

  6. Thermoeconomic evaluation of air conditioning system with chilled water storage

    International Nuclear Information System (INIS)

    Lin, Hu; Li, Xin-hong; Cheng, Peng-sheng; Xu, Bu-gong

    2014-01-01

    Highlights: • A new thermoeconomic evaluation methodology has been presented. • The relationship between thermodynamic and economic performances has been revealed. • A key point for thermal storage technology further application is discovered. • A system has been analyzed via the new method and EUD method. - Abstract: As a good load shifting technology for power grid, chilled energy storage has been paid more and more attention, but it always consumes more energy than traditional air conditioning system, and the performance analysis is mostly from the viewpoint of peak-valley power price to get cost saving. The paper presents a thermoeconomic evaluation methodology for the system with chilled energy storage, by which thermodynamic performance influence on cost saving has been revealed. And a system with chilled storage has been analyzed, which can save more than 15% of power cost with no energy consumption increment, and just certain difference between peak and valley power prices can make the technology for good economic application. The results show that difference between peak and valley power prices is not the only factor on economic performance, thermodynamic performance of the storage system is the more important factor, and too big price difference is a barrier for its application, instead of for more cost saving. All of these give a new direction for thermal storage technology application

  7. Evaluating Frequency Quality of Nordic System using PMU data

    DEFF Research Database (Denmark)

    Xu, Zhao; Østergaard, Jacob; Togeby, Mikael

    2008-01-01

    This paper focuses on analysing frequency quality of Nordic power system using measurements from Phasor Measurement Units (PMU). The PMU data of one year long period is used which has very high time resolution (20 ms per sample) and is able to provide detailed information in evaluating frequency...... quality and its correlation with time. The results show that the frequency quality of the Nordic power system is not satisfactory according to the suggested requirements. The electricity market operation is found to be one of the major reasons behind. Based on the results, discussion of frequency control...

  8. Multi-Criteria Evaluation of Energy Systems with Sustainability Considerations

    Directory of Open Access Journals (Sweden)

    Despoina E. Keramioti

    2010-04-01

    Full Text Available A multi-criteria approach is presented for the assessment of alternative means for covering the energy needs (electricity and heat of an industrial unit, taking into consideration sustainability aspects. The procedure is first described in general terms: proper indicators are defined; next they are grouped in order to form sub-indices, which are then used to determine the composite sustainability index. The procedure is applied for the evaluation of three alternative systems. The three systems are placed in order of preference, which depends on the criteria used. In addition to conclusions reached as a result of the particular case study, recommendations for future work are given.

  9. Integrated Evaluation of Closed Loop Air Revitalization System Components

    Science.gov (United States)

    Murdock, K.

    2010-01-01

    NASA s vision and mission statements include an emphasis on human exploration of space, which requires environmental control and life support technologies. This Contractor Report (CR) describes the development and evaluation of an Air Revitalization System, modeling and simulation of the components, and integrated hardware testing with the goal of better understanding the inherent capabilities and limitations of this closed loop system. Major components integrated and tested included a 4-Bed Modular Sieve, Mechanical Compressor Engineering Development Unit, Temperature Swing Adsorption Compressor, and a Sabatier Engineering and Development Unit. The requisite methodolgy and technical results are contained in this CR.

  10. Performance evaluation of the distance education system with fuzzy logic

    Science.gov (United States)

    Armaǧan, Hamit; Yiǧit, Tuncay

    2017-07-01

    Distance education is a kind of education that brought together course advisor, student and educational materials in a different time and place through communicational technologies. In this educational system the success of education is directly related to audio, video and interaction. In this study, a model is created by using fuzzy logic with the success of distance education students and the components of distance education. This study is made by MATLAB fuzzy logic toolbox. Audio, video, educational technology, student achievement are used as parameters in the evaluation. System assessment is carried out depending on parameter.

  11. Evaluation of demonstration technologies: Quail creek water supply system

    International Nuclear Information System (INIS)

    1993-02-01

    The U.S. EPA is currently demonstrating central and household treatment units at several sites in the U.S. The Quail Creek System near Spicewood, Texas is one of these sites where the technology demonstration program is scheduled to be completed soon as part of the EPA's Office of Ground Water and Drinking Water demonstration initiative. The report provides a summary of the small system demonstration project and presents an evaluation of the information collected during the operation, and by the EPA in September 1992

  12. Performance evaluation of photovoltaic systems on Kuwaiti schools’ rooftop

    International Nuclear Information System (INIS)

    Al-Otaibi, A.; Al-Qattan, A.; Fairouz, F.; Al-Mulla, A.

    2015-01-01

    Highlights: • Evaluation of rooftop PV installations at 2 Kuwaiti schools was carried out. • Lack of real plants data in the region and specifically Kuwait motivated the work. • Automated cleaning system allowed for minimization of soiling loss. • The average PV system performance was greater than 76%. • Schools show high potential for rooftop installations. - Abstract: Photovoltaic (PV) is a high-potential renewable energy technology for Kuwait to pursue due to high daily irradiation, and has garnered local attention in recent years due to the growing energy demand and concerns over climate change. As yet, no data are available regarding the actual performance of PV systems in Kuwait’s harsh environment. This paper presents a 12-month-long performance evaluation of the first 85.05 kW p and 21.6 kW p copper indium gallium selenide (CIGS) thin film, grid-connected PV systems on the rooftops of two schools. The schools’ monthly energy consumption and PV generation profiles, the actual performance of the PV plants, the effectiveness of automated cleaning systems on the power output, and the benefits of PV implementation in schools were analyzed and evaluated. Data analysis was applied to filter and normalize the data in order to identify the actual performance parameters. The findings of the study, based on solar irradiation collected, the performance of the module technology and the effectiveness of the automated cleaning systems, show that the performance ratio was maintained between 0.74 and 0.85. Furthermore, the minimum monthly energy yield of the PV systems was about 104 kW h/kW p . The annual average daily final yields of the PV systems in this study were 4.5 kW h/kW p /day. The results provided insight into the performance of CIGS grid-connected PV systems in Kuwait, and those data will be beneficial to the PV research community worldwide. School buildings, particularly for the rooftops, are a unique and important asset for urban PV system

  13. Performance Evaluation of a Biometric System Based on Acoustic Images

    Directory of Open Access Journals (Sweden)

    Juan J. Villacorta

    2011-10-01

    Full Text Available An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side. Two Uniform Linear Arrays (ULA with 15 l/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR/False Non-Match Rate (FNMR parameters and the Receiver Operating Characteristic (ROC curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications.

  14. Technical Evaluation Report 5: Classification of DE Delivery Systems

    Directory of Open Access Journals (Sweden)

    Diane Belyk

    2002-01-01

    Full Text Available For their optimal use in distance education (DE, online educational applications need to be integrated within a comprehensive course management system (CMS. Such systems are server-based software that supports the development, delivery, administration, and evaluation of online learning environments. The selection of an appropriate CMS should be considered from the multiple perspectives of the student, the course developer, the course instructor/ tutor, the technical support staff, and the DE institution’s administration. The current evaluation of CMS packages was conducted by a team of individuals with experience and contacts in relation to each of these DE user types. The report compares a series of CMS packages in terms of their range of features, and in relation to their satisfaction of international online education standards.

  15. Utilization and evaluation of computer system in radiology

    International Nuclear Information System (INIS)

    Akagi, Hiroaki; Kanasaki, Yoshiki; Hirai, Kazuzo

    1982-01-01

    Computer are now widely used in various fields of science on account of the progress and improvement in performance. In medicine, the utilization of computer started in nuclear medicine and has spread in radiology from CT (computed tomography), CUS (computed ultrasonography), ECT(emission comp uted tomography) to hospital automation by computer, which is now in progressing in several hospitals. In our Department of Radiology, planning and evaluation of computer system in radiology, especially for nuclear medicine have been achieved since 1972, and the results were summarized and reported in this paper in both side of clinical and basic evaluation on computer system. Experiments of hospital automation were written as an additional part of this paper for next step of the study. (author)

  16. System and method for evaluating a wire conductor

    Science.gov (United States)

    Panozzo, Edward; Parish, Harold

    2013-10-22

    A method of evaluating an electrically conductive wire segment having an insulated intermediate portion and non-insulated ends includes passing the insulated portion of the wire segment through an electrically conductive brush. According to the method, an electrical potential is established on the brush by a power source. The method also includes determining a value of electrical current that is conducted through the wire segment by the brush when the potential is established on the brush. The method additionally includes comparing the value of electrical current conducted through the wire segment with a predetermined current value to thereby evaluate the wire segment. A system for evaluating an electrically conductive wire segment is also disclosed.

  17. OWL2 benchmarking for the evaluation of knowledge based systems.

    Directory of Open Access Journals (Sweden)

    Sher Afgun Khan

    Full Text Available OWL2 semantics are becoming increasingly popular for the real domain applications like Gene engineering and health MIS. The present work identifies the research gap that negligible attention has been paid to the performance evaluation of Knowledge Base Systems (KBS using OWL2 semantics. To fulfil this identified research gap, an OWL2 benchmark for the evaluation of KBS is proposed. The proposed benchmark addresses the foundational blocks of an ontology benchmark i.e. data schema, workload and performance metrics. The proposed benchmark is tested on memory based, file based, relational database and graph based KBS for performance and scalability measures. The results show that the proposed benchmark is able to evaluate the behaviour of different state of the art KBS on OWL2 semantics. On the basis of the results, the end users (i.e. domain expert would be able to select a suitable KBS appropriate for his domain.

  18. Microclimate Cooling Systems: A Shipboard Evaluation of Commercial Models

    Science.gov (United States)

    1988-04-01

    NCTRF), under contract to the Navy SciencI Assistance Program (NSAP), evaluated the feasibility of using commercial microclimate coolin9" systems (MCS...6 e The cold air from the vortex tube is fed into the vest, while the warm sir is directed away from the user. The temperature and flow rate of the...did not use insulated thermistors, the chest temperature may have been greatly influenced by the cold liquid or air in direct contact with the measuring

  19. Development and Evaluation of a Prototype Barricade Lighting System

    OpenAIRE

    John Donovan Bullough; Jeremy David Snyder; Nicholas Paul Skinner; Mark Stanley Rea

    2012-01-01

    Presently in work zones, standard barricade warning lights are used to provide channelizing and warning functions. These yellow flashing lights are presently used for different work zone activities. Concepts for a non-standard barricade lighting system were developed and evaluated: flashing red lights when traffic is stopped or very slow within a work zone, flashing green lights when a work zone is inactive and traffic should proceed normally, expanding yellow lights when drivers should slow ...

  20. Multi-Criteria Evaluation of Energy Systems with Sustainability Considerations

    OpenAIRE

    Despoina E. Keramioti; Christos A. Frangopoulos

    2010-01-01

    A multi-criteria approach is presented for the assessment of alternative means for covering the energy needs (electricity and heat) of an industrial unit, taking into consideration sustainability aspects. The procedure is first described in general terms: proper indicators are defined; next they are grouped in order to form sub-indices, which are then used to determine the composite sustainability index. The procedure is applied for the evaluation of three alternative systems. The three syste...

  1. Long-term stake evaluations of waterborne copper systems

    Science.gov (United States)

    Stan Lebow; Cherilyn Hatfield; Douglas Crawford; Bessie Woodward

    2003-01-01

    Limitations on the use of chromated copper arsenate (CCA) have heightened interest in use of arsenic-free copper-based alternatives. For decades, the USDA Forest Products Laboratory has been evaluating several of these systems in stake plots. Southern Pine 38- by 89- by 457-mm (1.5- by 3.5- by 18-inch) stakes were treated with varying concentrations of acid copper...

  2. Teacher evaluation system, institutions of technology higher education: quality guidelines

    Directory of Open Access Journals (Sweden)

    Laura Belkis Parada Romero

    2016-01-01

    Full Text Available Due to the globalization of education, it has become prevalent to strengthen the quality systems to ensure that educational actors in higher education institutions are the best. In this context teachers are given a main role since they are cornerstones in educational processes. Currently, teacher quality is assessed through an assessment or evaluation system. Almost every university evaluates its teachers, but there is no legal regulation on how to do it, in most institutions there is a professional in charge of designing and applying assessment instruments according to the authors he/she prefers. In most universities, on the one hand, it is used a traditional questionnaire aiming to collect data about dimensions associated with teaching, on the other hand, there is another option in which assessment models include self-evaluation, as in some cases in Chile. That’s why one of the concerns of this research is to propose guidelines for a more qualitative and formative assessment not exclusively following political parameters –based on administrative decisions–, but following emerging proposals with a deeper analysis. Nowadays the main actors in teacher evaluation are teachers, students and administrative staff, every six months these actors are evaluated by using an assessment tool that they usually do not know. The research investigates the perception actors in teacher evaluation have regarding its objectives, methods and stages, so they put forward ideas on how to restructure the current institutional assessment and propose improvements aiming at both the quantitative aspect and the qualitative analysis of performances and skills.

  3. Regulation and quality evaluation system for HIV diagnostics in China.

    Science.gov (United States)

    Xu, Sihong; Huang, Weijin; Zhang, Li; An, Juanjuan; Li, Xiuhua; Song, Aijing; Nie, Jianhui; Zhang, Chuntao; Wang, Youchun

    2016-03-01

    A sophisticated regulatory framework has been constructed for Human immunodeficiency virus (HIV) diagnostics in China, which have developed over the past 30 years. China National Institutes for Food and Drug Control acts as the legal institution in this regulatory framework, launching important activities to ensure the quality of HIV diagnostics. These include the analysis of the main problems faced in developing domestic HIV diagnostics, by investigating the quality of HIV diagnostics and their development; exploring the key factors affecting the quality of HIV diagnostics, to determine the criteria for screening national reference samples; the development of new technologies and methods for preparing reference samples; and the establishment of nine types of national reference panels and nine national standards to evaluate the quality of HIV diagnostics. Based on these researches, a quality evaluation system was established, including nine types of national reference panels, nine national standards for HIV diagnostics, and five sample banks (HIV-positive sample bank, HIV-negative sample bank, common international genotype sample bank, seroconversion series sample bank, HIV virus bank) to evaluate the quality of HIV diagnostics in China. The regulatory framework and the quality evaluation system are pivotal in ensuring the quality of the HIV diagnostics licensed in China. Copyright © 2016 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  4. Evaluation of KFB-funded research on transport systems

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, D.; Knudsen, T.; Wegener, M.

    1999-09-01

    This report presents an evaluation of two research projects on transport systems, which have been financed fully or partially by KFB. The projects are: l. Systems analysis of transport markets at the Division of Transport and Location Analysis in the Department of Infrastructure and Planning of the Royal Institute of Technology, Stockholm; and 2. Planning, analysis and management in traffic networks - optimization models and methods at the Division of Optimization in the Department of Mathematics at Linkoeping University. The evaluation seeks to examine the scientific quality of the research and its relevance to the academic world and society. The two project teams prepared a self-assessment of their research activities and submitted copies of relevant publications. The evaluation committee visited both institutions and engaged the teams in discussions of their results and methodology. These visits occurred on June 1 and 2, 1999. This report is based on the self-assessments of the teams, the materials submitted and the meetings with the project teams. The evaluation and recommendations presented in the report are those of the reviewers and do not necessarily represent the views of KFB

  5. Evaluating Emulation-based Models of Distributed Computing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Stephen T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cyber Initiatives; Gabert, Kasimir G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cyber Initiatives; Tarman, Thomas D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Emulytics Initiatives

    2017-08-01

    Emulation-based models of distributed computing systems are collections of virtual ma- chines, virtual networks, and other emulation components configured to stand in for oper- ational systems when performing experimental science, training, analysis of design alterna- tives, test and evaluation, or idea generation. As with any tool, we should carefully evaluate whether our uses of emulation-based models are appropriate and justified. Otherwise, we run the risk of using a model incorrectly and creating meaningless results. The variety of uses of emulation-based models each have their own goals and deserve thoughtful evaluation. In this paper, we enumerate some of these uses and describe approaches that one can take to build an evidence-based case that a use of an emulation-based model is credible. Predictive uses of emulation-based models, where we expect a model to tell us something true about the real world, set the bar especially high and the principal evaluation method, called validation , is comensurately rigorous. We spend the majority of our time describing and demonstrating the validation of a simple predictive model using a well-established methodology inherited from decades of development in the compuational science and engineering community.

  6. Deep Charging Evaluation of Satellite Power and Communication System Components

    Science.gov (United States)

    Schneider, T. A.; Vaughn, J. A.; Chu, B.; Wong, F.; Gardiner, G.; Wright, K. H.; Phillips, B.

    2016-01-01

    Deep charging, in contrast to surface charging, focuses on electron penetration deep into insulating materials applied over conductors. A classic example of this scenario is an insulated wire. Deep charging can pose a threat to material integrity, and to sensitive electronics, when it gives rise to an electrostatic discharge or arc. With the advent of Electric Orbit Raising, which requires spiraling through Earth's radiation belts, satellites are subjected to high energy electron environments which they normally would not encounter. Beyond Earth orbit, missions to Jupiter and Saturn face deep charging concerns due to the high energy radiation environments. While predictions can be made about charging in insulating materials, it is difficult to extend those predictions to complicated geometries, such as the case of an insulating coating around a small wire, or a non-uniform silicone grouting on a bus bar. Therefore, to conclusively determine the susceptibility of a system to arcs from deep charging, experimental investigations must be carried out. This paper will describe the evaluation carried out by NASA's Marshall Space Flight Center on subscale flight-like samples developed by Space Systems/Loral, LLC. Specifically, deep charging evaluations of solar array wire coupons, a photovoltaic cell coupon, and a coaxial microwave transmission cable, will be discussed. The results of each evaluation will be benchmarked against control sample tests, as well as typical power system levels, to show no significant deep charging threat existed for this set of samples under the conditions tested.

  7. The human performance evaluation system at Virginia Power

    International Nuclear Information System (INIS)

    Smith, R.G. III.

    1989-01-01

    The safe operation of nuclear power plants requires high standards of performance, extensive training, and responsive management. Despite a utility's best efforts, inappropriate human actions do occur. Although such inappropriate actions will occur, it is believed that such actions can be minimized and managed. The Federal Aviation Administration has a successful program administered by the National Aeronautics and Space Administration. This program is called the Aviation Safety Reporting System (ASRS). Established in 1975, it is anonymous and nonpunitive. A trial program for several utilities was developed by the Institute of Nuclear Power Operations which used a concept similar to the ASRS reporting process. Based on valuable lessons learned by Virginia Power during the pilot program, an effort was made in 1986 to formalize the Human Performance Evaluation System (HPES) to establish an ongoing problem-solving system for evaluating human performance. Currently, 34 domestic utilities and 3 international utilities voluntarily participate in the implementation of the HPES. Each participating utility has selected and trained personnel to evaluate events involving human error and provide corrective action recommendations to prevent recurrence. It is believed that the use of the HPES can lead to improved safety and operation availability

  8. Evaluation of a Telerehabilitation System for Community-Based Rehabilitation

    Directory of Open Access Journals (Sweden)

    Jamie L Schutte

    2012-06-01

    Full Text Available The use of web-based portals, while increasing in popularity in the fields of medicine and research, are rarely reported on in community-based rehabilitation programs.  A program within the Pennsylvania Office of Vocational Rehabilitation’s Hiram G. Andrews Center, the Cognitive Skills Enhancement Program (CSEP, sought to enhance organization of program and participant information and communication between part- and full-time employees, supervisors and consultants. A telerehab system was developed consisting of (1 a web-based portal to support a variety of clinical activities and (2 the Versatile Integrated System for Telerehabilitation (VISyTER video-conferencing system to support the collaboration and delivery of rehabilitation services remotely.  This descriptive evaluation examines the usability of the telerehab system incorporating both the portal and VISyTER. Telerehab system users include CSEP staff members from three geographical locations and employed by two institutions. The IBM After-Scenario Questionnaire (ASQ and Post-Study System Usability Questionnaire (PSSUQ, the Telehealth Usability Questionnaire (TUQ, and two demographic surveys were administered to gather both objective and subjective information. Results showed generally high levels of usability.  Users commented that the telerehabilitation system improved communication, increased access to information, improved speed of completing tasks, and had an appealing interface. Areas where users would like to see improvements, including ease of accessing/editing documents and searching for information, are discussed.         

  9. Evaluating physical protection systems of licensed nuclear facilities using systems engineered inspection guidance

    International Nuclear Information System (INIS)

    Bradley, R.T.; Olson, A.W.; Rogue, F.; Scala, S.; Richard, E.W.

    1980-01-01

    The Lawrence Livermore National Laboratory (LLNL) and the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) have applied a systems engineering approach to provide the NRC Office of Inspection and Enforcement (IE) with improved methods and guidance for evaluating the physical protection systems of licensed nuclear facilities

  10. The Artemis workbench for system-level performance evaluation of embedded systems

    NARCIS (Netherlands)

    Pimentel, A.D.

    2008-01-01

    In this paper, we present an overview of the Artemis workbench, which provides modelling and simulation methods and tools for efficient performance evaluation and exploration of heterogeneous embedded multimedia systems. More specifically, we describe the Artemis system-level modelling methodology,

  11. Evaluating accounting information systems that support multiple GAAP reporting using Normalized Systems Theory

    NARCIS (Netherlands)

    Vanhoof, E.; Huysmans, P.; Aerts, Walter; Verelst, J.; Aveiro, D.; Tribolet, J.; Gouveia, D.

    2014-01-01

    This paper uses a mixed methods approach of design science and case study research to evaluate structures of Accounting Information Systems (AIS) that report in multiple Generally Accepted Accounting Principles (GAAP), using Normalized Systems Theory (NST). To comply with regulation, many companies

  12. Environmental Impact Evaluation of Aircraft at System-of-Systems Level

    NARCIS (Netherlands)

    Schroijen, M.J.T.; Van Tooren, M.J.L.; Voskuijl, M.; Curran, R.

    2011-01-01

    Next generations of civil transport aircraft will need to be evaluated not only against their behaviour as an aircraft system but also as a part of the larger air transport system. In addition to this are the sustainability issues related to for instance noise and emissions, represented by

  13. Development of design window evaluation and display system. 1. System development and performance confirmation

    International Nuclear Information System (INIS)

    Muramatsu, Toshiharu; Yamaguchi, Akira

    2003-07-01

    Purpose: The work was performed to develop a design window evaluation and display system for the purpose of obtaining the effects of various design parameters on the typical thermal hydraulic issues resulting from a use of various kind of working fluid etc. easily. Method: The function of the system were 'confirmation of design margin' of the present design, 'confirmation of the affected design zone' when a designer changed some design parameter, and search for an design improvement' for design optimization. The system was developed using existing soft wares on PC and the database relating analytical results of typical thermal hydraulic issues provided by separate work. Results: (1) System design: In order to develop a design window evaluation and display system, 'numerical analysis unit', 'statistical analysis unit', 'MMI unit', 'optimization unit' were designed based on the result of selected optimization procedure and display visualization. Further, total system design was performed combining these units. Typical thermal hydraulic issues to be considered are upper plenum thermal hydraulics, thermal stratification, free surface sloshing, flow-induced vibration of a heat exchanger and thermal striping in the T-junction piping systems. (2) Development of prototype system and a functional check: A prototype system of a design window evaluation and display system was developed and the functions were confirmed as was planned. (author)

  14. Comparison of economic evaluation methodology between levelized method and the evaluation system in China

    International Nuclear Information System (INIS)

    Zhang Shengli

    2005-01-01

    Different methodology would bring different results. This paper includes an introduction of levelized discounted generation cost methodology as well as that of Chinese system, respectively. In general, there have two key indices in Chinese evaluation system, they are generation cost and electricity sales price to the grid. This paper contains a description of cost breakdown and calculation procedure for each index. Comparison between these two methods and the primary differences are also included. For the first time, equations for calculating generation cost and selling price to the grid based on Chinese system have been derived, and its accuracy has been shown through running the special computer program. The two systems are quite different in many aspects. Firstly, levelized generation cost is always calculated with discounted method that excluded in Chinese system. Secondly, levelized generation cost is a single and constant value that would not change over the economic life while generation cost in Chinese system is estimated on a year by year base. Thirdly, the makeup of generation cost in Chinese system is different from that of levelized system since taxes and dividend share removed. Finally, the electricity sales price in Chinese system is more similar to levelized generation cost. (authors)

  15. Evaluation of digital detector arrays systems for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Aline S.S.; Oliveira, Davi F.; Gomes, Célio S.; Azeredo, Soraia R.; Lopes, Ricardo T., E-mail: aline@lin.ufrj.br, E-mail: davi@lin.ufrj.br.br, E-mail: celio@lin.ufrj.br, E-mail: soraia@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br, E-mail: davi.oliveira@uerj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear

    2017-07-01

    Digital Detector Arrays (DDA) or Flat Panel Detector (FPD) is a highly efficient technique that is used in nondestructive testing of internal features of an object. The evaluation of DDA systems for industrial radiography is important to ensure the image quality and to enables long-term stability of this system. This evaluation is specified by ASTM E2737 - 10, which describes the fundamental parameters of DDA systems to be measured. The tests require the usage of either the five-groove wedge or the duplex plate phantom with separate Image Quality Indicators (IQIs). The purpose of this work was evaluate the radiographic performance achieved using both techniques in two DDA systems manufactured by GEIT: DXR250P and DXR250V, which have thallium-doped cesium iodide (CsI:Tl) and terbium-doped gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb - GOS) scintillators, respectively. For this purpose, it was used an X-ray equipment as radiation source. The image quality parameters analyzed were Image Lag (IL), Offset Level (OL), Bad Pixel distribution, Burn In (BI), Spatial Resolution (SR), Material Thickness Range (MTR), Contrast Sensitivity (CS), Signal Level (SL) and Signal-to-Noise Ratio (SNR). As result of this study, has been observed that the use of the five-groove wedge phantom made the measurements to become easier to execute. Regarding the DDA system, the DXR250P presented more IL and BI, but produced images with better CS and SNR and needed a dose almost twice smaller than the DXR250V to achieve a similar SL. (author)

  16. Transgenic Arabidopsis Gene Expression System

    Science.gov (United States)

    Ferl, Robert; Paul, Anna-Lisa

    2009-01-01

    The Transgenic Arabidopsis Gene Expression System (TAGES) investigation is one in a pair of investigations that use the Advanced Biological Research System (ABRS) facility. TAGES uses Arabidopsis thaliana, thale cress, with sensor promoter-reporter gene constructs that render the plants as biomonitors (an organism used to determine the quality of the surrounding environment) of their environment using real-time nondestructive Green Fluorescent Protein (GFP) imagery and traditional postflight analyses.

  17. Development of Probabilistic Reliability Models of Photovoltaic System Topologies for System Adequacy Evaluation

    Directory of Open Access Journals (Sweden)

    Ahmad Alferidi

    2017-02-01

    Full Text Available The contribution of solar power in electric power systems has been increasing rapidly due to its environmentally friendly nature. Photovoltaic (PV systems contain solar cell panels, power electronic converters, high power switching and often transformers. These components collectively play an important role in shaping the reliability of PV systems. Moreover, the power output of PV systems is variable, so it cannot be controlled as easily as conventional generation due to the unpredictable nature of weather conditions. Therefore, solar power has a different influence on generating system reliability compared to conventional power sources. Recently, different PV system designs have been constructed to maximize the output power of PV systems. These different designs are commonly adopted based on the scale of a PV system. Large-scale grid-connected PV systems are generally connected in a centralized or a string structure. Central and string PV schemes are different in terms of connecting the inverter to PV arrays. Micro-inverter systems are recognized as a third PV system topology. It is therefore important to evaluate the reliability contribution of PV systems under these topologies. This work utilizes a probabilistic technique to develop a power output model for a PV generation system. A reliability model is then developed for a PV integrated power system in order to assess the reliability and energy contribution of the solar system to meet overall system demand. The developed model is applied to a small isolated power unit to evaluate system adequacy and capacity level of a PV system considering the three topologies.

  18. Evaluation of on-site wastewater treatment systems

    International Nuclear Information System (INIS)

    Dunn, J.

    2002-01-01

    'Full text:' This presentation will describe the nature, scope, and findings of a program designed to conduct a third-party group evaluation of wastewater denitrification technologies appropriate for low-flow systems, partially funded by a grant from the Pennsylvania Department of Environmental Protection (PADEP). The objective of this program is to verify the performance of products that provide nutrient reduction in wastewater from a variety of sources, including domestic wastewater, agricultural runoff, or other waste streams. The evaluation process will be overseen and coordinated by the Environmental Technology Evaluation Center (EvTEC), a program of the Civil Engineering Research Foundation (CERF), the research and technology transfer arm of the American Society of Civil Engineers (ASCE). EvTEC is a pilot program evaluating innovative environmental technologies under the US Environmental Protection Agency's (USEPA) Environmental Technology Verification (ETV) Program. Among other performance issues, the potential energy savings of using nutrient reducing technologies scaled to treat low flows - larger than an individual septic tank but smaller than that of a conventional wastewater treatment plant - will be assessed. The energy savings realized by reduced construction and equipment transport costs alone could make low-flow nutrient reduction technologies viable options for rural communities, small farms, and other low-flow settings. The evaluation is being funded in part by PADEP, which is sponsoring this evaluation due to its interest in developing low-cost wastewater treatment technologies for Pennsylvania's rural communities. However, the evaluation is national in scope, and participants will come from all areas of the country. The presentation will include a description of the process for establishing the testing protocol, testing results from various nutrient reducing technologies, and obstacles encountered and lessons learned during the process. (author)

  19. Evaluating system reliability and targeted hardening strategies of power distribution systems subjected to hurricanes

    International Nuclear Information System (INIS)

    Salman, Abdullahi M.; Li, Yue; Stewart, Mark G.

    2015-01-01

    Over the years, power distribution systems have been vulnerable to extensive damage from hurricanes which can cause power outage resulting in millions of dollars of economic losses and restoration costs. Most of the outage is as a result of failure of distribution support structures. Over the years, various methods of strengthening distribution systems have been proposed and studied. Some of these methods, such as undergrounding of the system, have been shown to be unjustified from an economic point of view. A potential cost-effective strategy is targeted hardening of the system. This, however, requires a method of determining critical parts of a system that when strengthened, will have greater impact on reliability. This paper presents a framework for studying the effectiveness of targeted hardening strategies on power distribution systems subjected to hurricanes. The framework includes a methodology for evaluating system reliability that relates failure of poles and power delivery, determination of critical parts of a system, hurricane hazard analysis, and consideration of decay of distribution poles. The framework also incorporates cost analysis that considers economic losses due to power outage. A notional power distribution system is used to demonstrate the framework by evaluating and comparing the effectiveness of three hardening measures. - Highlight: • Risk assessment of power distribution systems subjected to hurricanes is carried out. • Framework for studying effectiveness of targeted hardening strategies is presented. • A system reliability method is proposed. • Targeted hardening is cost effective for existing systems. • Economic losses due to power outage should be considered for cost analysis.

  20. Reliability evaluation of the Savannah River reactor leak detection system

    International Nuclear Information System (INIS)

    Daugherty, W.L.; Sindelar, R.L.; Wallace, I.T.

    1991-01-01

    The Savannah River Reactors have been in operation since the mid-1950's. The primary degradation mode for the primary coolant loop piping is intergranular stress corrosion cracking. The leak-before-break (LBB) capability of the primary system piping has been demonstrated as part of an overall structural integrity evaluation. One element of the LBB analyses is a reliability evaluation of the leak detection system. The most sensitive element of the leak detection system is the airborne tritium monitors. The presence of small amounts of tritium in the heavy water coolant provide the basis for a very sensitive system of leak detection. The reliability of the tritium monitors to properly identify a crack leaking at a rate of either 50 or 300 lb/day (0.004 or 0.023 gpm, respectively) has been characterized. These leak rates correspond to action points for which specific operator actions are required. High reliability has been demonstrated using standard fault tree techniques. The probability of not detecting a leak within an assumed mission time of 24 hours is estimated to be approximately 5 x 10 -5 per demand. This result is obtained for both leak rates considered. The methodology and assumptions used to obtain this result are described in this paper. 3 refs., 1 fig., 1 tab

  1. A smart sensor-based vision system: implementation and evaluation

    International Nuclear Information System (INIS)

    Elouardi, A; Bouaziz, S; Dupret, A; Lacassagne, L; Klein, J O; Reynaud, R

    2006-01-01

    One of the methods of solving the computational complexity of image-processing is to perform some low-level computations on the sensor focal plane. This paper presents a vision system based on a smart sensor. PARIS1 (Programmable Analog Retina-like Image Sensor1) is the first prototype used to evaluate the architecture of an on-chip vision system based on such a sensor coupled with a microcontroller. The smart sensor integrates a set of analog and digital computing units. This architecture paves the way for a more compact vision system and increases the performances reducing the data flow exchanges with a microprocessor in control. A system has been implemented as a proof-of-concept and has enabled us to evaluate the performance requirements for a possible integration of a microcontroller on the same chip. The used approach is compared with two architectures implementing CMOS active pixel sensors (APS) and interfaced to the same microcontroller. The comparison is related to image processing computation time, processing reliability, programmability, precision, bandwidth and subsequent stages of computations

  2. Evaluating the Maturity of Cybersecurity Programs for Building Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Glantz, Clifford S.; Somasundaram, Sriram; Mylrea, Michael E.; Underhill, Ronald M.; Nicholls, Andrew K.

    2016-08-29

    The cyber-physical security threat to buildings is complex, non-linear, and rapidly evolving as operational and information technologies converge and connect buildings to cyberspace. Cyberattacks on buildings can exploit smart building controls and breach corporate networks, causing financial and reputational damage. This may result in the loss of sensitive building information or the disruption of, or damage to, the systems necessary for the safe and efficient operation of buildings. For the buildings and facility infrastructure, there is a need for a robust national cybersecurity strategy for buildings, guidance on the selection and implementation of appropriate cybersecurity controls for buildings, an approach to evaluate the maturity and adequacy of the cybersecurity programs. To provide an approach for evaluating the maturity of the cybersecurity programs for building control systems, the US Department of Energy’s widely used Cybersecurity Capability and Maturity Model (C2M2) has been adapted into a building control systems version. The revised model, the Buildings-C2M2 (B-C2M2) provides maturity level indicators for cybersecurity programmatic domains. A “B-C2M2 Lite” version allows facility managers and building control system engineers, or information technology personnel to perform rapid self-assessments of their cybersecurity program. Both tools have been pilot tested on several facilities. This paper outlines the concept of a maturity model, describes the B-C2M2 tools, presents results and observations from the pilot assessments, and lays out plans for future work.

  3. Evaluation of two ozone air quality modelling systems

    Directory of Open Access Journals (Sweden)

    S. Ortega

    2004-01-01

    Full Text Available The aim of this paper is to compare two different modelling systems and to evaluate their ability to simulate high values of ozone concentration in typical summer episodes which take place in the north of Spain near the metropolitan area of Barcelona. As the focus of the paper is the comparison of the two systems, we do not attempt to improve the agreement by adjusting the emission inventory or model parameters. The first model, or forecasting system, is made up of three modules. The first module is a mesoscale model (MASS. This provides the initial condition for the second module, which is a nonlocal boundary layer model based on the transilient turbulence scheme. The third module is a photochemical box model (OZIPR, which is applied in Eulerian and Lagrangian modes and receives suitable information from the two previous modules. The model forecast is evaluated against ground base stations during summer 2001. The second model is the MM5/UAM-V. This is a grid model designed to predict the hourly three-dimensional ozone concentration fields. The model is applied during an ozone episode that occurred between 21 and 23 June 2001. Our results reflect the good performance of the two modelling systems when they are used in a specific episode.

  4. Module-based quality system functionality evaluation in production logistics

    Energy Technology Data Exchange (ETDEWEB)

    Khabbazi, M.R.; Wikander, J.; Onori, M.; Maffei, A.; Chen, D.

    2016-07-01

    This paper addresses a comprehensive modeling and functionality evaluation of a module-based quality system in production logistics at the highest domain abstract level of business processes. All domain quality business processes and quality data transactions are modeled using BPMN and UML tools and standards at the business process and data modeling. A modular web-based prototype is developed to evaluate the models addressing the quality information system functionality requirements and modularity in production logistics through data scenarios and data queries. Using the object-oriented technique in design at the highest domain level, the proposed models are subject further development in the lower levels for the implementing case. The models are specifically able to manipulate all quality operations including remedy and control in a lot-based make-to-order production logistics system as an individual module. Due to the specification of system as domain design structure, all proposed BPMs, data models, and the actual database prototype are seen referential if not a solution as a practical “to-be” quality business process re-engineering template. This paper sets out to provide an explanatory approach using different practical technique at modeling steps as well as the prototype implementation. (Author)

  5. Evaluation of a laser alignment system for IORT satellite applicators

    International Nuclear Information System (INIS)

    Boyer, A.L.; Hogstrom, R.; Ochran, T.G.

    1988-01-01

    A laser alignment system has been developed and tested for air docking applicators to a Siemens ME dedicated intraoperative linear accelerator. A series of three circular anuli collimate the electron beams. The first two anuli are rigidly attached to the collimator. The third anulus is attached to the top of the 30-cm-long treatment cones. A 15-cm air gap separates the cone anulus from the rest of the collimation. The cone is held rigidly to a Marquet surgical table by a Bookwalter clamp. Electrically controlled table motions are used to align the cone with the aid of the laser alignment system. The authors' measurements have shown that a cone angulation of more than 1 0 from true alignment causes significant field asymmetry. However, they have found that the laser system allows repeatable alignment of the cone to better than 0.5 0 . The accuracy and stability of the lasers is therefore quite important. The system's design and evaluation are presented in detail. The evaluation includes isodose distributions fro aligned and misaligned cones

  6. Solar energy system economic evaluation for IBM System 3, Glendo, Wyoming

    Science.gov (United States)

    1980-01-01

    This analysis was based on the technical and economic models in f-chart design procedures with inputs based on the characteristics of the parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings, and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables was also investigated.

  7. Sub system and component level safety classification evaluation and identification for tank farm safety systems

    International Nuclear Information System (INIS)

    JANICEK, G.P.

    2001-01-01

    This document provides the safety classification, and classification rationale, for all elements of (some) Tank Farm Safety Systems identified in the Tank Farms Final Safety Analyses. It also contains the official Safety Equipment List (SEL) for the safety systems evaluated. The initial issue of this document does not address all Tank Farm safety systems. The remainder will be addressed, and incorporated in this document, in subsequent revisions

  8. Load calculation and system evaluation for electric vehicle climate control

    International Nuclear Information System (INIS)

    Aceves-Saborio, S.; Comfort, W.J.

    1994-01-01

    Providing air conditioning for electric vehicles (EV's) represents an important challenge, because vapor-compression air conditioners, which are common in gasoline-powered vehicles, may consume a substantial part of the total energy stored in the EV battery. The authors' work has two major parts: a cooling and heating load calculation for EV's, and an evaluation of several systems that can be used to provide the desired cooling and heating in EV's. Four cases are studied: short-range and full-range EV's are each analyzed twice, first with the regular vehicle equipment, and then with a fan and heat-reflecting windows, to reduce hot soak. Results indicate that for the batteries currently available for EV propulsion, an ice storage system has the minimum weight of all the systems considered. Vapor-compression air conditioners have the minimum for battery storage capacities above 270 kJ/kg

  9. Evaluation of rare-earth imaging systems in panoramic radiography

    International Nuclear Information System (INIS)

    Gratt, B.M.; White, S.C.; Packard, F.L.; Petersson, A.R.

    1984-01-01

    Panoramic radiographs were made of ninety-nine consenting adult patients who had image-analysis test devices placed within their oral cavities. Quantitative characteristics and perceived image quality of eight screen-film combinations were investigated. The quantitative characteristics of the images evaluated included contrast, resolution (in three regions), and bead detection (a measure of noise). Perceived image quality assessed similar characteristics. In addition, expert observers rated the resultant patient radiographs for both general and specific diagnostic tasks. Calcium tungstate screen-film systems were found to have the highest contrast but with resolution comparable to rare-earth screen-film systems under clinical test conditions. Calcium tungstate systems required up to twice the radiation exposure of the patient. It was found that some rare-earth screen-film combinations may produce clinically acceptable panoramic radiographs while reducing the patient's radiation exposure

  10. Participatory ergonomics for psychological factors evaluation in work system design.

    Science.gov (United States)

    Wang, Lingyan; Lau, Henry Y K

    2012-01-01

    It is a well recognized understanding that workers whose voice needs to be heard should be actively encouraged as full participants and involved in the early design stages of new ergonomic work system which encompass the development and implementation of new tools, workplaces, technologies or organizations. This paper presents a novel participatory strategy to evaluate three key psychological factors which are respectively mental fatigue, spiritual stress, and emotional satisfaction in work system design based on a modified version of Participatory Ergonomics (PE). In specific, it integrates a PE technique with a formulation view by combining the parallel development of PE strategies, frameworks and functions throughout the coverage of the entire work system design process, so as to bridge the gap between qualitative and quantitative analysis of psychological factors which can cause adverse or advantageous effects on worker's physiological and behavioral performance.

  11. Expert System Approach For Generating And Evaluating Engine Design Alternatives

    Science.gov (United States)

    Shen, Stewart N. T.; Chew, Meng-Sang; Issa, Ghassan F.

    1989-03-01

    Artificial intelligence is becoming an increasingly important subject of study for computer scientists, engineering designers, as well as professionals in other fields. Even though AI technology is a relatively new discipline, many of its concepts have already found practical applications. Expert systems, in particular, have made significant contributions to technologies in such fields as business, medicine, engineering design, chemistry, and particle physics. This paper describes an expert system developed to aid the mechanical designer with the preliminary design of variable-stroke internal-combustion engines. The expert system accomplished its task by generating and evaluating a large number of design alternatives represented in the form of graphs. Through the application of structural and design rules directly to the graphs, optimal and near optimal preliminary design configurations of engines are deduced.

  12. Analysis of Photovoltaic System Energy Performance Evaluation Method

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Newmiller, J.; Kimber, A.; Flottemesch, R.; Riley, E.; Dierauf, T.; McKee, J.; Krishnani, P.

    2013-11-01

    Documentation of the energy yield of a large photovoltaic (PV) system over a substantial period can be useful to measure a performance guarantee, as an assessment of the health of the system, for verification of a performance model to then be applied to a new system, or for a variety of other purposes. Although the measurement of this performance metric might appear to be straight forward, there are a number of subtleties associated with variations in weather and imperfect data collection that complicate the determination and data analysis. A performance assessment is most valuable when it is completed with a very low uncertainty and when the subtleties are systematically addressed, yet currently no standard exists to guide this process. This report summarizes a draft methodology for an Energy Performance Evaluation Method, the philosophy behind the draft method, and the lessons that were learned by implementing the method.

  13. Designing and evaluating risk-based surveillance systems

    DEFF Research Database (Denmark)

    Willeberg, Preben; Nielsen, Liza Rosenbaum; Salman, Mo

    2012-01-01

    Risk-based surveillance systems reveal occurrence of disease or infection in a sample of population units, which are selected on the basis of risk factors for the condition under study. The purpose of such systems for supporting practical animal disease policy formulations and management decisions...... are: A: to detect an emerging disease or infection, if it becomes introduced into a population; or B: to substantiate freedom from a condition in a population; or C: to detect cases and estimate the prevalence of an endemic condition in a population. In risk-based surveillance these aims should be met...... applicable risk estimate for use in designing and evaluating a risk-based surveillance system would be a crude (unadjusted) relative risk, odds ratio or apparent prevalence. Risk estimates found in the published literature, however, are often the results of multivariable analyses implicitly adjusting...

  14. A Systems Approach to Evaluate One Health Initiatives.

    Science.gov (United States)

    Rüegg, Simon R; Nielsen, Liza Rosenbaum; Buttigieg, Sandra C; Santa, Mijalche; Aragrande, Maurizio; Canali, Massimo; Ehlinger, Timothy; Chantziaras, Ilias; Boriani, Elena; Radeski, Miroslav; Bruce, Mieghan; Queenan, Kevin; Häsler, Barbara

    2018-01-01

    Challenges calling for integrated approaches to health, such as the One Health (OH) approach, typically arise from the intertwined spheres of humans, animals, and ecosystems constituting their environment. Initiatives addressing such wicked problems commonly consist of complex structures and dynamics. As a result of the EU COST Action (TD 1404) "Network for Evaluation of One Health" (NEOH), we propose an evaluation framework anchored in systems theory to address the intrinsic complexity of OH initiatives and regard them as subsystems of the context within which they operate. Typically, they intend to influence a system with a view to improve human, animal, and environmental health. The NEOH evaluation framework consists of four overarching elements, namely: (1) the definition of the initiative and its context, (2) the description of the theory of change with an assessment of expected and unexpected outcomes, (3) the process evaluation of operational and supporting infrastructures (the "OH-ness"), and (4) an assessment of the association(s) between the process evaluation and the outcomes produced. It relies on a mixed methods approach by combining a descriptive and qualitative assessment with a semi-quantitative scoring for the evaluation of the degree and structural balance of "OH-ness" (summarised in an OH-index and OH-ratio, respectively) and conventional metrics for different outcomes in a multi-criteria-decision-analysis. Here, we focus on the methodology for Elements (1) and (3) including ready-to-use Microsoft Excel spreadsheets for the assessment of the "OH-ness". We also provide an overview of Element (2), and refer to the NEOH handbook for further details, also regarding Element (4) (http://neoh.onehealthglobal.net). The presented approach helps researchers, practitioners, and evaluators to conceptualise and conduct evaluations of integrated approaches to health and facilitates comparison and learning across different OH activities thereby facilitating

  15. A Literature Review on Recommender Systems Algorithms, Techniques and Evaluations

    Directory of Open Access Journals (Sweden)

    Kasra Madadipouya

    2017-07-01

    Full Text Available One of the most crucial issues, nowadays, is to provide personalized services to each individual based on their preferences. To achieve this goal, recommender system could be utilized as a tool to help the users in decision-making process offering different items and options. They are utilized to predict and recommend relevant items to end users. In this case an item could be anything such as a document, a location, a movie, an article or even a user (friend suggestion. The main objective of the recommender systems is to suggest items which have great potential to be liked by users. In modern recommender systems, various methods are combined together with the aim of extracting patterns in available datasets. Combination of different algorithms make prediction more convoluted since various parameters should be taken into account in providing recommendations. Recommendations could be personalized or non-personalized. In non-personalized type, selection of the items for a user is based on the number of the times that an item has been visited in the past by other users. However, in the personalized type, the main objective is to provide the best items to the user based on her taste and preferences. Although, in many domains recommender systems gained significant improvements and provide better services for users, it still requires further research to improve accuracy of recommendations in many aspects. In fact, the current available recommender systems are far from the ideal model of the recommender system. This paper reviews state of art in recommender systems algorithms and techniques which is necessary to identify the gaps and improvement areas. In addition to that, we provide possible solutions to overcome shortages and known issues of recommender systems as well as discussing about recommender systems evaluation methods and metrics in details.

  16. Evaluation of Interference Performance of Fm-Dcsk Communications System

    Science.gov (United States)

    Kis, Gábor

    In addition to channel noise, the received signal in a radio communications system is corrupted by interferences. This paper evaluates by simulation the performance of a Frequency-Modulated Differential Chaos Shift Keying (FM-DCSK) modulation scheme when the radio channel suffers from strong interferences. First, the effect of another FM-DCSK radio signal transmitted in the same RF frequency band is considered. We show that the degradation in system performance depends on the bit durations of the two interfering FM-DCSK systems. The worst case occurs when the bit durations of the two systems coincide; a slight difference between the two bit durations reduces considerably the degradation in system performance. Then the FM-DCSK system is tested in an industrial environment where large spikes are present. These spikes cause large transients in the channel filter. Because an FM-DCSK signal can be demodulated by a nonlinear receiver, these transients can be eliminated by using a hard limiter in the receiver.

  17. Evaluation of a documentation system for airway management training.

    Science.gov (United States)

    Cone, Stephen W; Rafiq, Azhar; Merrell, Ronald C

    2008-01-01

    Resuscitation science is a dynamic part of healthcare training, with an expanding role for simulation. Historically, performance measurement and documentation relied upon the presence of an instructor, an expensive and potentially inaccurate assessment tradition that tied performance testing to a fixed facility. We hypothesize that an automated system might be developed and validated to document performance in airway management for self assessment in the absence of a human trainer. The system would also store and transmit data to a central registry to document skill acquisition and maintenance. Multiple video and pressure inputs captured and documented resuscitation task performance on a readily available standard practice manikin. Bag-valve-mask ventilation (BVM), endotracheal intubation, and ventilation via endotracheal tube (ETT) were studied for accuracy, adequacy, and time. The 12 participants performed each task for 5 repetitions, resulting in 60 total attempts for each skill. Twelve untrained participants performed 3 critical tasks in airway management. Review with the system informed the participant of his/her performance and desired outcome. The system also documented skill performance objectively relative to a standard, recording both successes and failures. Compressed and abstracted performance records populated an average 14-megabyte file size (excluding full motion video). This system was successfully used to document student performance of BVM, orotracheal intubation, and ventilation via ETT. The system easily integrates documentation, including text reports, airway pressure readings, still images and videos of task performance. Such digital documentation could guide skill acquisition and quantitatively certify performance with minimal reliance upon an instructor and evaluator.

  18. Freva - Freie Univ Evaluation System Framework for Scientific HPC Infrastructures in Earth System Modeling

    Science.gov (United States)

    Kadow, C.; Illing, S.; Schartner, T.; Grieger, J.; Kirchner, I.; Rust, H.; Cubasch, U.; Ulbrich, U.

    2017-12-01

    The Freie Univ Evaluation System Framework (Freva - freva.met.fu-berlin.de) is a software infrastructure for standardized data and tool solutions in Earth system science (e.g. www-miklip.dkrz.de, cmip-eval.dkrz.de). Freva runs on high performance computers to handle customizable evaluation systems of research projects, institutes or universities. It combines different software technologies into one common hybrid infrastructure, including all features present in the shell and web environment. The database interface satisfies the international standards provided by the Earth System Grid Federation (ESGF). Freva indexes different data projects into one common search environment by storing the meta data information of the self-describing model, reanalysis and observational data sets in a database. This implemented meta data system with its advanced but easy-to-handle search tool supports users, developers and their plugins to retrieve the required information. A generic application programming interface (API) allows scientific developers to connect their analysis tools with the evaluation system independently of the programming language used. Users of the evaluation techniques benefit from the common interface of the evaluation system without any need to understand the different scripting languages. The integrated web-shell (shellinabox) adds a degree of freedom in the choice of the working environment and can be used as a gate to the research projects HPC. Plugins are able to integrate their e.g. post-processed results into the database of the user. This allows e.g. post-processing plugins to feed statistical analysis plugins, which fosters an active exchange between plugin developers of a research project. Additionally, the history and configuration sub-system stores every analysis performed with the evaluation system in a database. Configurations and results of the tools can be shared among scientists via shell or web system. Furthermore, if configurations match

  19. Computer-implemented security evaluation methods, security evaluation systems, and articles of manufacture

    Science.gov (United States)

    Muller, George; Perkins, Casey J.; Lancaster, Mary J.; MacDonald, Douglas G.; Clements, Samuel L.; Hutton, William J.; Patrick, Scott W.; Key, Bradley Robert

    2015-07-28

    Computer-implemented security evaluation methods, security evaluation systems, and articles of manufacture are described. According to one aspect, a computer-implemented security evaluation method includes accessing information regarding a physical architecture and a cyber architecture of a facility, building a model of the facility comprising a plurality of physical areas of the physical architecture, a plurality of cyber areas of the cyber architecture, and a plurality of pathways between the physical areas and the cyber areas, identifying a target within the facility, executing the model a plurality of times to simulate a plurality of attacks against the target by an adversary traversing at least one of the areas in the physical domain and at least one of the areas in the cyber domain, and using results of the executing, providing information regarding a security risk of the facility with respect to the target.

  20. The evaluation system of city's smart growth success rates

    Science.gov (United States)

    Huang, Yifan

    2018-04-01

    "Smart growth" is to pursue the best integrated perform+-ance of the Economically prosperous, socially Equitable, and Environmentally Sustainable(3E). Firstly, we establish the smart growth evaluation system(SGI) and the sustainable development evaluation system(SDI). Based on the ten principles and the definition of three E's of sustainability. B y using the Z-score method and the principal component analysis method, we evaluate and quantify indexes synthetically. Then we define the success of smart growth as the ratio of the SDI to the SGI composite score growth rate (SSG). After that we select two cities — Canberra and Durres as the objects of our model in view of the model. Based on the development plans and key data of these two cities, we can figure out the success of smart growth. And according to our model, we adjust some of the growth indicators for both cities. Then observe the results before and after adjustment, and finally verify the accuracy of the model.

  1. PHARMACODYNAMICAL EVALUATION OF MATRIX TYPE TRANSDERMAL THERAPEUTIC SYSTEMS CONTAINING CAPTOPRIL.

    Science.gov (United States)

    Kerımoğlu, Oya; Şahbaz, Sevınç; Şehırlı, Özer; Ozdemır, Zarıfe Nıgar; Çetınel, Şule; Dortunç, Betül; Şener, Göksel

    2015-01-01

    The objective of this study was to evaluate pharmacodynamical properties of transdermal therapeutic systems (TTS) containing captopril together with synthetic and pH independent polymers, Eudragit RL 100 and RS 100. Optimum formulation was chosen according to the results of our previous study regarding in vitro dissolution and ex vivo diffusion rate studies through excised human skin by using Franz Diffusion Cell. Control group, hypertension group (HT) and TTS containing captopril hypertension group (HT-CAP) were assessed for the pharmacodynamic activity of the study. Pharmacodynamic activity of transdermal patches containing captopril was evaluated in rats by the measurement of systolic blood pressure for 24 h with the use of the tail cuff method. Blood pressure, heart rate, body and heart weight, heart and body weight ratio were determined. Lactate dehydrogenase (LDH), creatinine phosphokinase (CPK), glutathione (GSH), malondialdehyde (MDA), myeloperoxidase (MPO) and Na+, K(+)-ATPase were measured in the serum of rats. Histopathological evaluation of the heart tissue was conducted in order to determine any tissue damage. Blood pressure values of the TTS containing captopril hypertension group were decreased significantly and became almost similar with the blood pressure values of the control group. These results indicated that matrix type transdermal patches prepared with Eudragit RL 100 and RS 100 polymers containing captopril can be considered as transdermal therapeutic systems for chronical treatment of hypertension and congestive heart failure. However, further in vivo pharmacokinetic studies should be performed in order to determine the blood level of the drug.

  2. The transport performance evaluation system building of logistics enterprises

    Directory of Open Access Journals (Sweden)

    Xueli Wang

    2013-09-01

    Full Text Available Purpose: modern logistics has a significant role in today’s society, logistics cost accounts for 35% to 50% of total logistics costs, so it’s great significance to improve the transport performance of logistics enterprises. Design/methodology/approach: the authors select the transportation performance evaluation index of logistics enterprise, with the aid of the fuzzy theory and analytic hierarchy process (AHP, adopt the combining method of quantitative and qualitative analysis, construct the transport performance evaluation system of logistics enterprises. Findings: the choice of transport performance evaluation indicator system for Logistics enterprise is in a state of "high", which indicates the indicator selection is reasonable. Research limitations/implications: the selected indicators with experts’ subjective factors can not accurately quantify. Practical implications: it has important practical significance to promote the development of modern logistics enterprises and save social cost. Originality/value: current research methods mainly include the PDCA cycle model, key performance indicators (KPI and benchmarking method, principal component analysis method, etc. The authors for the first time with the aid of fuzzy theory and analytic hierarchy process (AHP, adopt the combining method of quantitative and qualitative research on transport performance problems.

  3. Evaluating the effectiveness of active vehicle safety systems.

    Science.gov (United States)

    Jeong, Eunbi; Oh, Cheol

    2017-03-01

    Advanced vehicle safety systems have been widely introduced in transportation systems and are expected to enhance traffic safety. However, these technologies mainly focus on assisting individual vehicles that are equipped with them, and less effort has been made to identify the effect of vehicular technologies on the traffic stream. This study proposed a methodology to assess the effectiveness of active vehicle safety systems (AVSSs), which represent a promising technology to prevent traffic crashes and mitigate injury severity. The proposed AVSS consists of longitudinal and lateral vehicle control systems, which corresponds to the Level 2 vehicle automation presented by the National Highway Safety Administration (NHTSA). The effectiveness evaluation for the proposed technology was conducted in terms of crash potential reduction and congestion mitigation. A microscopic traffic simulator, VISSIM, was used to simulate freeway traffic stream and collect vehicle-maneuvering data. In addition, an external application program interface, VISSIM's COM-interface, was used to implement the AVSS. A surrogate safety assessment model (SSAM) was used to derive indirect safety measures to evaluate the effectiveness of the AVSS. A 16.7-km freeway stretch between the Nakdong and Seonsan interchanges on Korean freeway 45 was selected for the simulation experiments to evaluate the effectiveness of AVSS. A total of five simulation runs for each evaluation scenario were conducted. For the non-incident conditions, the rear-end and lane-change conflicts were reduced by 78.8% and 17.3%, respectively, under the level of service (LOS) D traffic conditions. In addition, the average delay was reduced by 55.5%. However, the system's effectiveness was weakened in the LOS A-C categories. Under incident traffic conditions, the number of rear-end conflicts was reduced by approximately 9.7%. Vehicle delays were reduced by approximately 43.9% with 100% of market penetration rate (MPR). These results

  4. Use of the Long Duration Exposure Facility's thermal measurement system for the verification of thermal models

    Science.gov (United States)

    Berrios, William M.

    1992-01-01

    The Long Duration Exposure Facility (LDEF) postflight thermal model predicted temperatures were matched to flight temperature data recorded by the Thermal Measurement System (THERM), LDEF experiment P0003. Flight temperatures, recorded at intervals of approximately 112 minutes for the first 390 days of LDEF's 2105 day mission were compared with predictions using the thermal mathematical model (TMM). This model was unverified prior to flight. The postflight analysis has reduced the thermal model uncertainty at the temperature sensor locations from +/- 40 F to +/- 18 F. The improved temperature predictions will be used by the LDEF's principal investigators to calculate improved flight temperatures experienced by 57 experiments located on 86 trays of the facility.

  5. The calcium endocrine system of adolescent rhesus monkeys and controls before and after spaceflight

    Science.gov (United States)

    Arnaud, Sara B.; Navidi, Meena; Deftos, Leonard; Thierry-Palmer, Myrtle; Dotsenko, Rita; Bigbee, Allison; Grindeland, Richard E.

    2002-01-01

    The calcium endocrine system of nonhuman primates can be influenced by chairing for safety and the weightless environment of spaceflight. The serum of two rhesus monkeys flown on the Bion 11 mission was assayed pre- and postflight for vitamin D metabolites, parathyroid hormone, calcitonin, parameters of calcium homeostasis, cortisol, and indexes of renal function. Results were compared with the same measures from five monkeys before and after chairing for a flight simulation study. Concentrations of 1,25-dihydroxyvitamin D were 72% lower after the flight than before, and more than after chairing on the ground (57%, P parathyroid hormone did not reach significance. Calcitonin showed modest decreases postflight (P animals.

  6. Risk evaluation system for operational events and inspection findings

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, A.; Godinez S, V.; Lopez M, R., E-mail: alopezg@cnsns.gob.m [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2010-10-15

    The Mexican Nuclear Regulatory Commission has developed an adaptation of the US NRC Significance Determination Process (SDP) to evaluate the risk significance of operational events and inspection findings in Laguna Verde nuclear power plant. The Mexican Nuclear Regulatory Commission developed a plant specific flow chart for preliminary screening instead of the open questionnaire used by the US NRC-SDP, with the aim to improve the accuracy of the screening process. Also, the work sheets and support information tables required by the SDP were built up in an Excel application which allows to perform the risk evaluation in an automatic way, focusing the regulator staff efforts in the risk significance analysis instead of the risk calculation tasks. In order to construct this tool a simplified PRA model was developed and validated with the individual plant examination model. This paper shows the Mexican Nuclear Regulatory Commission process and some risk events evaluations performed using the Risk Evaluation System for Operational Events and Inspection Findings (SERHE, by its acronyms in Spanish). (Author)

  7. Risk evaluation system for operational events and inspection findings

    International Nuclear Information System (INIS)

    Lopez G, A.; Godinez S, V.; Lopez M, R.

    2010-10-01

    The Mexican Nuclear Regulatory Commission has developed an adaptation of the US NRC Significance Determination Process (SDP) to evaluate the risk significance of operational events and inspection findings in Laguna Verde nuclear power plant. The Mexican Nuclear Regulatory Commission developed a plant specific flow chart for preliminary screening instead of the open questionnaire used by the US NRC-SDP, with the aim to improve the accuracy of the screening process. Also, the work sheets and support information tables required by the SDP were built up in an Excel application which allows to perform the risk evaluation in an automatic way, focusing the regulator staff efforts in the risk significance analysis instead of the risk calculation tasks. In order to construct this tool a simplified PRA model was developed and validated with the individual plant examination model. This paper shows the Mexican Nuclear Regulatory Commission process and some risk events evaluations performed using the Risk Evaluation System for Operational Events and Inspection Findings (SERHE, by its acronyms in Spanish). (Author)

  8. Evaluation of Roadmap to Achieve Energy Delivery Systems Cybersecurity

    Energy Technology Data Exchange (ETDEWEB)

    Chavez, Adrian R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-01

    The Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) Cybersecurity for Energy Delivery Systems (CEDS) program is currently evaluating the Roadmap to Achieve Energy Delivery Systems Cybersecurity document that sets a vision and outlines a set of milestones. The milestones are divided into five strategic focus areas that include: 1. Build a Culture of Security; 2. Assess and Monitor Risk; 3. Develop and Implement New Protective Measures to Reduce Risk; 4. Manage Incidents; and 5. Sustain Security Improvements. The most current version of the roadmap was last updated in September of 2016. Sandia National Laboratories (SNL) has been tasked with revisiting the roadmap to update the current state of energy delivery systems cybersecurity protections. SNL is currently working with previous and current partners to provide feedback on which of the roadmap milestones have been met and to identify any preexisting or new gaps that are not addressed by the roadmap. The specific focus areas SNL was asked to evaluate are: 1. Develop and Implement New Protective Measures to Reduce Risk and 2. Sustain Security Improvements. SNL has formed an Industry Advisory Board (IAB) to assist in answering these questions. The IAB consists of previous partners on past CEDS funded efforts as well as new collaborators that have unique insights into the current state of cybersecurity within energy delivery systems. The IAB includes asset owners, utilities and vendors of control systems. SNL will continue to maintain regular communications with the IAB to provide various perspectives on potential future updates to further improve the breadth of cybersecurity coverage of the roadmap.

  9. Thermo economical evaluation of retrofitting strategies in air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Tribess, Arlindo; Fiorelli, Flavio Augusto Sanzogo; Hernandez Neto, Alberto [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: atribess@usp.br; fiorelli@usp.br; ahneto@usp.br

    2000-07-01

    In a building project, several subsystems are designed, among them the air conditioning system. Electrical energy consumption profiles show that this subsystem is responsible for 40 to 50% of total consumption in a commercial building. Besides the study of technical aspects that should be considered in order to assure the thermal comfort of the occupants as well the temperature and humidity conditions for an efficient equipment operation, an economical evaluation of this subsystem should be also made. In retrofit projects, the economical aspect is also critical for such projects in order to assure bigger efficiency in an economically attractive way. This paper analyses some strategies that might be adopted in retrofitting an air conditioning system installed in a commercial building with mixed occupation. By mixed we mean that some floors have a typical office occupation profile and other floors are mainly occupied by electronic equipment. This analysis includes both technical and economical evaluation. The proposed solutions performance are compared to the old system, which allows to verify the retrofitting impact in energy consumption reduction and its economical feasibility. (author)

  10. Evaluation of respiratory system in textile-dyeing workers.

    Science.gov (United States)

    Salmani Nodoushan, Mojahede; Mehrparvar, Amir Houshang; Loukzadeh, Ziba; Rahimian, Masoud; Ghove Nodoushan, Mohamad Ali; Jafari Nodoushan, Reza

    2014-01-01

    Despite the presence of many textile and dyeing plants in Iran, we couldn't find similar studies in this country. Forthermore, considering progress in the dyeing process and engineering controls, assessment of respiratory system is important for these workers. The present study was performed to evaluate the respiratory system in dyeing workers. In a cross-sectional study, 101 dyeing workers (all dyeing workers in yazd) and 90 workers without respiratory exposures (control group), were evaluated. A questionnaire was filled for each participant included Venables questionnaire and some other questions about age, work experience, personal or familial history of asthma or atopy, acute and chronic respiratory symptoms; Then spirometry was performed before and after the shift work Results: The frequency of acute and chronic respiratory symptoms was significantly higher among dyeing workers than controls. According to the Venables questionnaire, 11.9% of the dyeing workers suffered from asthma. Means of FVC and FEV1 of pre-shift spirometry were lower than control (prespiratory system in this study showed that despite development in dyeing processes and engineering controls, workers in this job show more prevalent acute and chronic symptoms, and across-shift changes in spirometric parameters were significantly higher in this work group than the control group. Therefore it is necessary to pay attention to the control of respiratory exposures in this job.

  11. Methodology for surge pressure evaluation in a water injection system

    Energy Technology Data Exchange (ETDEWEB)

    Meliande, Patricia; Nascimento, Elson A. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Engenharia Civil; Mascarenhas, Flavio C.B. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Lab. de Hidraulica Computacional; Dandoulakis, Joao P. [SHELL of Brazil, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Predicting transient effects, known as surge pressures, is of high importance for offshore industry. It involves detailed computer modeling that attempts to simulate the complex interaction between flow line and fluid in order to ensure efficient system integrity. Platform process operators normally raise concerns whether the water injection system is adequately designed or not to be protected against possible surge pressures during sudden valve closure. This report aims to evaluate the surge pressures in Bijupira and Salema water injection systems due to valve closure, through a computer model simulation. Comparisons among the results from empirical formulations are discussed and supplementary analysis for Salema system were performed in order to define the maximum volumetric flow rate for which the design pressure was able to withstand. Maximum surge pressure values of 287.76 bar and 318.58 bar, obtained in Salema and Bijupira respectively, using empirical formulations have surpassed the operating pressure design, while the computer model results have pointed the greatest surge pressure value of 282 bar in Salema system. (author)

  12. ACS sampling system: design, implementation, and performance evaluation

    Science.gov (United States)

    Di Marcantonio, Paolo; Cirami, Roberto; Chiozzi, Gianluca

    2004-09-01

    By means of ACS (ALMA Common Software) framework we designed and implemented a sampling system which allows sampling of every Characteristic Component Property with a specific, user-defined, sustained frequency limited only by the hardware. Collected data are sent to various clients (one or more Java plotting widgets, a dedicated GUI or a COTS application) using the ACS/CORBA Notification Channel. The data transport is optimized: samples are cached locally and sent in packets with a lower and user-defined frequency to keep network load under control. Simultaneous sampling of the Properties of different Components is also possible. Together with the design and implementation issues we present the performance of the sampling system evaluated on two different platforms: on a VME based system using VxWorks RTOS (currently adopted by ALMA) and on a PC/104+ embedded platform using Red Hat 9 Linux operating system. The PC/104+ solution offers, as an alternative, a low cost PC compatible hardware environment with free and open operating system.

  13. Optimal planning and economic evaluation of cogeneration system

    International Nuclear Information System (INIS)

    Oh, Si-Doek; Lee, Ho-Jun; Jung, Jung-Yeul; Kwak, Ho-Young

    2007-01-01

    Cogeneration plants, which simultaneously produce electricity and heat energy, have been introduced increasingly for commercial and domestic applications in Korea because of their energy efficiency. The optimal plant configuration of a specific commercial building can be determined by selecting the sizes and the number of cogeneration systems and the auxiliary equipment based on the annual demands of electricity, heating and cooling. In this study, a mixed-integer, linear programming, utilizing the branch and bound algorithm was used to obtain the optimal solution. Both the optimal configuration system equipment and the optimal operational mode were determined based on the annual cost method for the installation of a cogeneration system to a hospital and a group of apartments in Seoul, Korea. In addition, the economic evaluation for the optimal cogeneration system depending on the fuel tariff system was calculated. A short payback period and higher internal rate of return on the initial investment were found to be essential for the adoption of cogeneration plants to hospitals and apartments

  14. Optimal planning and economic evaluation of cogeneration system

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Si-Doek; Lee, Ho-Jun [Hyosung Corporation, Bangbae B/D, 1006-2, Bangbae-Dong, Seocho-Ku, Seoul 137-850 (Korea); Jung, Jung-Yeul; Kwak, Ho-Young [Mechanical Engineering Department, Chung-Ang University, 221, Huksuk-Dong, Dongjak-Gu, Seoul 156-756 (Korea)

    2007-05-15

    Cogeneration plants, which simultaneously produce electricity and heat energy, have been introduced increasingly for commercial and domestic applications in Korea because of their energy efficiency. The optimal plant configuration of a specific commercial building can be determined by selecting the sizes and the number of cogeneration systems and the auxiliary equipment based on the annual demands of electricity, heating and cooling. In this study, a mixed-integer, linear programming, utilizing the branch and bound algorithm was used to obtain the optimal solution. Both the optimal configuration system equipment and the optimal operational mode were determined based on the annual cost method for the installation of a cogeneration system to a hospital and a group of apartments in Seoul, Korea. In addition, the economic evaluation for the optimal cogeneration system depending on the fuel tariff system was calculated. A short payback period and higher internal rate of return on the initial investment were found to be essential for the adoption of cogeneration plants to hospitals and apartments. (author)

  15. Development of evaluation system of ultrasonic testing data

    International Nuclear Information System (INIS)

    Takeuchi, Iwao; Morimoto, Kazuo; Hamana, Michio; Taniguchi, Masaru; Hiraga, Seiji

    1996-01-01

    Mitsubishi Heavy Industries, Ltd. performs non-destructive inspections on water pipes and construction in power stations and various plants. For countermeasures concerning efficient operating with extra safety for long time operating of plants, our customers have asked us for detection with more accurate inspections and improvements on evaluation skills for sizing defects. For these requirements we have adopted noise removal methods such as split-spectrum processing(SSP) and sizing technique for detects such as time of flight diffraction(TOFD). We developed accurate and easily operating evaluation systems which made detection for defects and sizing of defects which are highly developed. We have become possible to perform non-destructive inspections efficiently and effectively. (author)

  16. A thermodynamic evaluation of the Fe-Nb system

    International Nuclear Information System (INIS)

    Srikanth, S.; Petric, A.

    1994-01-01

    An optimised set of thermodynamic functions consistent with the phase diagram was derived for the Fe-Nb system from information on phase equilibria and thermodynamic data available in the literature. The thermodynamic properties of the intermediate ε (Fe 2 Nb) phase were described using the sublattice model. A Redlich-Kister equation was used to describe the excess thermodynamic functions of the liquid, bcc and fcc phases. For the μ phase, the enthalpy of formation was estimated from Miedema's model. The interaction coefficients were evaluated using an optimisation procedure employing a conjugate gradient method. The phase diagram and the thermodynamic functions calculated from the evaluated parameters are in good agreement with experimental data. (orig.)

  17. An evaluation of intelligent prognostic systems for colorectal cancer.

    Science.gov (United States)

    Anand, S S; Smith, A E; Hamilton, P W; Anand, J S; Hughes, J G; Bartels, P H

    1999-02-01

    In this paper we describe attempts at building a robust model for predicting the length of survival of patients with colorectal cancer. The aim of the research, reported in this paper, is to study the effective utilisation of artificial intelligence techniques in the medical domain. We suggest that an important research objective of proponents of intelligent prognostic systems must be to evaluate the additionality that AI techniques can bring to an already well-established field of medical prognosis. Towards this end, we compare a number of different AI techniques that lend themselves to the task of predicting survival in colorectal cancer patients. We describe the pros and cons of each of these methods using the usual metrics of accuracy and perspicuity. We then present the notion of intelligent hybrid systems and evaluate the role that they may potentially play in developing robust prognostic models. In particular we evaluate a hybrid system that utilises the k Nearest Neighbour technique in conjunction with Genetic Algorithms. We describe a number of innovations used within this hybrid paradigm used to build the prognostic model. We discuss the issue of censored patients and how this issue can be tackled within the various models used. In keeping with our objective of studying the additionality that AI techniques bring to building prognostic models, we use Cox's regression as a standard and compare each AI technique with it, attempting to discover their capabilities in enhancing prognostic methods in medicine. In doing so we address two main questions--which model fits the data best?, and are the results obtained by the various AI techniques significantly different from those of Cox's regression? We conclude this paper by discussing future enhancements to the work presented and lessons learned from the study to date.

  18. Evaluation on usefulness of stereotactic radio surgery using Fraxion system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Won; Park, Kwang Woo; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoon Jin; Kim, Sei Joon; Kim, Jong Dae; Shin, Dong Bong [Dept. of Radiation Oncology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2014-12-15

    We evaluated the usefulness of Fraxion system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while Fraxion system was used for the other 3 patients (group 2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when Fraxion system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using Fraxion system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when sthermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using Fraxion system showed only 1.9%. All percentage were calculated with respect to average value. Using Fraxion system including mouthpiece, Fraxion frame, front piece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

  19. Performance evaluation of propulsion systems as LEO deorbiting devices

    Directory of Open Access Journals (Sweden)

    Alexandru IONEL

    2017-09-01

    Full Text Available This paper evaluates the possibility of deorbiting a launch vehicle upper-stage at end-of-mission from low Earth orbit, by using an additional propulsion system as a means of achieving deorbiting and complying with the “25 years” mitigation regulation. The deorbiting performances of chemical and electrical propulsion are analyzed through a MATLAB code which integrates orbital perturbations such as gravitational acceleration, atmospheric drag and rocket engine/motor thrust. Additionally, the research is placed within a body of similar papers concerned with deorbiting by means of propulsion, by performing a state of the art study.

  20. Shuttle systems evaluation and selection. Volume 1: Executive summary

    Science.gov (United States)

    1971-01-01

    The major issues affecting the selection of a space shuttle system were considered. These included the HO orbiter/ballistic recoverable booster series-burn configuration; the HO orbiter/ballistic recoverable booster parallel-burn (rocket-assisted orbiter-RAO) configuration; and the HO orbiter/flyback LOX/RP booster configuration. The booster studies emphasized the series-burn ballistic design, but the differences required for RAO application were identified and evaluated. Definition of the RAO configuration parameters and technical problem areas, establishing approaches to possible solutions, and developing program costs are discussed.

  1. Evaluation of Nanoclay Exfoliation Strategies for Thermoset Polyimide Nanocomposite Systems

    Science.gov (United States)

    Ginter, Michael J.; Jana, Sadhan C.; Miller, Sandi G.

    2007-01-01

    Prior works show exfoliated layered silicate reinforcement improves polymer composite properties. However, achieving full clay exfoliation in high performance thermoset polyimides remains a challenge. This study explores a new method of clay exfoliation, which includes clay intercalation by lower molecular weight PMR monomer under conditions of low and high shear and sonication, clay treatments by aliphatic and aromatic surfactants, and clay dispersion in primary, higher molecular weight PMR resin. Clay spacing, thermal, and mechanical properties were evaluated and compared with the best results available in literature for PMR polyimide systems.

  2. Study on Evaluation Index System of Green mine construction

    Science.gov (United States)

    Li, xin; Yang, JunJie; Yan, Hongcai; Cao, Hongjun

    2017-11-01

    Green mine is a new and science comprehensive construction mode of mine, which runs the concept of green development through the whole process of mineral resources development and utilization, promotes the transformation and upgrading of mineral enterprises and achieves the healthy and sustainable development of mining industry. This paper is based on “the basic conditions of national green mine”, combined with the current situation of green mine construction, constructing green mine construction evaluation index system which is divided into five areas, including management, comprehensive utilization of mineral resources. technological innovation. ecological environment and cultural construction.

  3. A bioenergetics systems evaluation of ketogenic diet liver effects.

    Science.gov (United States)

    Hutfles, Lewis J; Wilkins, Heather M; Koppel, Scott J; Weidling, Ian W; Selfridge, J Eva; Tan, Eephie; Thyfault, John P; Slawson, Chad; Fenton, Aron W; Zhu, Hao; Swerdlow, Russell H

    2017-09-01

    Ketogenic diets induce hepatocyte fatty acid oxidation and ketone body production. To further evaluate how ketogenic diets affect hepatocyte bioenergetic infrastructure, we analyzed livers from C57Bl/6J male mice maintained for 1 month on a ketogenic or standard chow diet. Compared with the standard diet, the ketogenic diet increased cytosolic and mitochondrial protein acetylation and also altered protein succinylation patterns. SIRT3 protein decreased while SIRT5 protein increased, and gluconeogenesis, oxidative phosphorylation, and mitochondrial biogenesis pathway proteins were variably and likely strategically altered. The pattern of changes observed can be used to inform a broader systems overview of how ketogenic diets affect liver bioenergetics.

  4. Evaluation of a Binaural Reproduction System Using Multiple Dipoles

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia; Rubak, Per

    2010-01-01

    The sweet spot size of  different loudspeaker configurations was investigated in a previous study carried out by the authors.  Closely spaced loudspeakers showed a wider control area than the standard stereo setup.  The sweet spot with respect to head rotations showed to be especially large when...... the listener.  The system is based on the idea of dividing the sound reproduction into regions to reduce front-back confusions and enhance the virtual experience without the aid of a head tracker.  A set of subjective experiments with the intention of evaluating and comparing the performance of the proposed...

  5. Development and evaluation of a Gamma Camera tuning system

    International Nuclear Information System (INIS)

    Arista Romeu, E. J.; Diaz Garcia, A.; Osorio Deliz, J. F.

    2015-01-01

    Correct operation of conventional analogue Gamma Cameras implies a good conformation of the position signals that correspond to a specific photo-peak of the radionuclide of interest. In order to achieve this goal the energy spectrum from each photo multiplier tube (PMT) has to be set within the same energy window. For this reason a reliable tuning system is an important part of all gamma cameras processing systems. In this work is being tested and evaluated a new prototype of tuning card that was developed and setting up for this purpose. The hardware and software of the circuit allow the regulation if each PMT high voltage. By this means a proper gain control for each of them is accomplished. The Tuning Card prototype was simulated in a virtual model and its satisfactory operation was proven in a Siemens Orbiter Gamma Camera. (Author)

  6. Evaluating a tobacco leaf humidification system involving nebulisation

    Directory of Open Access Journals (Sweden)

    Néstor Enrique Cerquera Peña

    2010-05-01

    Full Text Available A tobacco leaf humidifying system involving nebulisation was designned, implemented and evaluated; it had a system for monitoring and recording environmental conditions thereby producing an environment having more homogeneous relative humidity, ensuring better water use, better control of relative humidity and better control in managing cured tobacco leaf moisture content, thereby leading to a consequent improvement in final product quality. 55% to 75% relative humidity and 4 to 6 hour working ranges were obtained to en- sure leaf humidification reached 16% humidity on a wet basis. Two new designs are proposed for the conditioning stage regarding this conditioning chamber’s operational management, based on the results and field observations, which would allow better leaf management, thereby avoiding the risk of losses due to manipulation and over-humidification. This work strengthens research in the field of tobacco pos- tharvest technology, complementing other research projects which have been carried out in Colombia.

  7. Use of computer programs to evaluate effectiveness of security systems

    International Nuclear Information System (INIS)

    Harris, L. Jr.; Goldman, L.A.; Mc Daniel, T.L.

    1987-01-01

    Thirty or more computer programs for security vulnerability analysis were developed from 1975 through 1980. Most of these programs are intended for evaluating security system effectiveness against outsider threats, but at least six programs are primarily oriented to insider threats. Some strengths and weaknesses of these programs are described. Six of these programs, four for outsider threats and two for insider threats, have been revised and adapted for use with IBM personal computers. The vulnerability analysis process is discussed with emphasis on data collection. The difference between design data and operational data is described. For performance-type operational data, such as detection probabilities and barrier delay times, the difference between unstressed and stressed performance data is discussed. Stressed performance data correspond to situations where an adversary attempts to weaken a security system by mitigating certain security measures. Suggestions are made on the combined use of manual analysis and computer analysis

  8. Use of computer programs to evaluate effectiveness of security systems

    Energy Technology Data Exchange (ETDEWEB)

    Harris, L. Jr.; Goldman, L.A.; Mc Daniel, T.L.

    1987-07-01

    Thirty or more computer programs for security vulnerability analysis were developed from 1975 through 1980. Most of these programs are intended for evaluating security system effectiveness against outsider threats, but at least six programs are primarily oriented to insider threats. Some strengths and weaknesses of these programs are described. Six of these programs, four for outsider threats and two for insider threats, have been revised and adapted for use with IBM personal computers. The vulnerability analysis process is discussed with emphasis on data collection. The difference between design data and operational data is described. For performance-type operational data, such as detection probabilities and barrier delay times, the difference between unstressed and stressed performance data is discussed. Stressed performance data correspond to situations where an adversary attempts to weaken a security system by mitigating certain security measures. Suggestions are made on the combined use of manual analysis and computer analysis.

  9. Numerical evaluation of the performance of active noise control systems

    Science.gov (United States)

    Mollo, C. G.; Bernhard, R. J.

    1990-01-01

    This paper presents a generalized numerical technique for evaluating the optimal performance of active noise controllers. In this technique, the indirect BEM numerical procedures are used to derive the active noise controllers for optimal control of enclosed harmonic sound fields where the strength of the noise sources or the description of the enclosure boundary may not be known. The performance prediction for a single-input single-output system is presented, together with the analysis of the stability and observability of an active noise-control system employing detectors. The numerical procedures presented can be used for the design of both the physical configuration and the electronic components of the optimal active noise controller.

  10. Evaluation of an improved air distribution system for aircraft cabin

    DEFF Research Database (Denmark)

    Pang, Liping; Xu, Jie; Fang, Lei

    2013-01-01

    of contaminated air above the head of the passengers. The improved pattern may overcome the above challenges quite well while also delivering good ventilation performance. The modified Personal Exposure Effectiveness (PEE) was measured to compare their performances with regard to inhaled air quality. The measured......An improved air distribution system for aircraft cabin was proposed in this paper. Personalized outlets were introduced and placed at the bottom of the baggage hold. Its ratio of fresh air to recirculation air and the conditioned temperature of different types of inlets were also designed carefully...... to meet the goals of high air quality, thermal comfort and energy saving. Some experiments were conducted to evaluate and compare its performances with two other systems. First the Flow Visualization with Green Laser (FVGL) technology was used to analyze the air flow. The top-in-side bottom-out pattern...

  11. Human factors in automatic image retrieval system design and evaluation

    Science.gov (United States)

    Jaimes, Alejandro

    2006-01-01

    Image retrieval is a human-centered task: images are created by people and are ultimately accessed and used by people for human-related activities. In designing image retrieval systems and algorithms, or measuring their performance, it is therefore imperative to consider the conditions that surround both the indexing of image content and the retrieval. This includes examining the different levels of interpretation for retrieval, possible search strategies, and image uses. Furthermore, we must consider different levels of similarity and the role of human factors such as culture, memory, and personal context. This paper takes a human-centered perspective in outlining levels of description, types of users, search strategies, image uses, and human factors that affect the construction and evaluation of automatic content-based retrieval systems, such as human memory, context, and subjectivity.

  12. Online hyperspectral imaging system for evaluating quality of agricultural products

    Science.gov (United States)

    Mo, Changyeun; Kim, Giyoung; Lim, Jongguk

    2017-06-01

    The consumption of fresh-cut agricultural produce in Korea has been growing. The browning of fresh-cut vegetables that occurs during storage and foreign substances such as worms and slugs are some of the main causes of consumers' concerns with respect to safety and hygiene. The purpose of this study is to develop an on-line system for evaluating quality of agricultural products using hyperspectral imaging technology. The online evaluation system with single visible-near infrared hyperspectral camera in the range of 400 nm to 1000 nm that can assess quality of both surfaces of agricultural products such as fresh-cut lettuce was designed. Algorithms to detect browning surface were developed for this system. The optimal wavebands for discriminating between browning and sound lettuce as well as between browning lettuce and the conveyor belt were investigated using the correlation analysis and the one-way analysis of variance method. The imaging algorithms to discriminate the browning lettuces were developed using the optimal wavebands. The ratio image (RI) algorithm of the 533 nm and 697 nm images (RI533/697) for abaxial surface lettuce and the ratio image algorithm (RI533/697) and subtraction image (SI) algorithm (SI538-697) for adaxial surface lettuce had the highest classification accuracies. The classification accuracy of browning and sound lettuce was 100.0% and above 96.0%, respectively, for the both surfaces. The overall results show that the online hyperspectral imaging system could potentially be used to assess quality of agricultural products.

  13. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  14. Unilateral Laryngeal Pacing System and Its Functional Evaluation

    Directory of Open Access Journals (Sweden)

    Taiping Zeng

    2017-01-01

    Full Text Available Goal. To establish a reliable instrumental system for synchronized reactivation of a unilaterally paralyzed vocal fold and evaluate its functional feasibility. Methods. Unilateral vocal fold paralysis model was induced by destruction of the left recurrent laryngeal nerve (RLN in anesthetized dogs. With a micro controller-based electronic system, electromyography (EMG signals from cricothyroid (CT muscle on the ipsilateral side were recorded and used to trigger pacing of paralyzed vocalis muscles. The dynamic movement of vocal folds was continuously monitored using an endoscope, and the opening and closing of the glottis were quantified with customized imaging processing software. Results. The recorded video images showed that left side vocal fold was obviously paralyzed after destructing the RLN. Using the pacing system with feedback triggering EMG signals from the ipsilateral CT muscle, the paralyzed vocal fold was successfully reactivated, and its movement was shown to be synchronized with the healthy side. Significance. The developed unilateral laryngeal pacing system triggered by EMG from the ipsilateral side CT muscle could be successfully used in unilateral vocal fold paralysis with the advantage of avoiding disturbance to the healthy side muscles.

  15. INEL test plan for evaluating waste assay systems

    International Nuclear Information System (INIS)

    Mandler, J.W.; Becker, G.K.; Harker, Y.D.; Menkhaus, D.E.; Clements, T.L. Jr.

    1996-09-01

    A test bed is being established at the Idaho National Engineering Laboratory (INEL) Radioactive Waste Management Complex (RWMC). These tests are currently focused on mobile or portable radioassay systems. Prior to disposal of TRU waste at the Waste Isolation Pilot Plant (WIPP), radioassay measurements must meet the quality assurance objectives of the TRU Waste Characterization Quality Assurance Program Plan. This test plan provides technology holders with the opportunity to assess radioassay system performance through a three-tiered test program that consists of: (a) evaluations using non-interfering matrices, (b) surrogate drums with contents that resemble the attributes of INEL-specific waste forms, and (c) real waste tests. Qualified sources containing a known mixture and range of radionuclides will be used for the non-interfering and surrogate waste tests. The results of these tests will provide technology holders with information concerning radioassay system performance and provide the INEL with data useful for making decisions concerning alternative or improved radioassay systems that could support disposal of waste at WIPP

  16. Operative and economic evaluation of a 'Laser Printer Multimodality' System

    International Nuclear Information System (INIS)

    Battaglia, G.; Moscatelli, G.; Maroldi, R.; Chiesa, A.

    1991-01-01

    The increasing application of digital techniques to diagnostic imaging is causing significant changes in several related activities, such as a reproduction of digital images on film. In the Department of Diagnostic Imaging of the University of Brescia, about 70% of the whole of images are produced by digital techniques; at present, most of these images are reproduced on film with a Multimodality System interfacing CT, MR, DSA, and DR units with a single laser printer. Our analysis evaluates the operative and economics aspects of image reproduction, by comparing the 'single cassette' multiformat Camera and the Laser Printer Multimodality SAystem. Our results point out the advantages obtained by reproducing images with a Laser Printer Multimodality System: outstanding quality, reproduction of multiple originals, and marked reduction in the time needed for both image archiving and film handling. The Laser Printer Multimodality System allows over 5 hours/day to be saved -that is to say the working day of an operator, who can be thus shifted to other functions. The important economic aspect of the reproduction of digital images on film proves the Laser Printer Multimodality System to have some advantage over Cameras

  17. Performance Evaluation of Terrestrial Emergency Communication System in NPPs

    International Nuclear Information System (INIS)

    Son, Gwang Sub; Kim, Chang Hwoi; Kang, Hyun Gook

    2014-01-01

    The Fukushima accident induced by the great earthquake and tsunami reveals the vulnerability of I and C System. In the severe environment, the normal I and C system did not work properly and results in false information about the internal situation in NPP. Eventually the accident was not properly handled at the early stage. Therefore advanced emergency response system using a wireless channel is necessary to cope with the severe accident. In this paper, we introduce the ERS consisting of the HMS and MCS the ECS linking the HMS with MCS and the performance requirement of the ECS is analyzed. The ECS satisfying the requirement is designed conceptually and the performance of the ECS is evaluated through analysis and simulator. The terrestrial communication system is designed based on the IEEE 802.11. Analyzed performance results prove that the performance requirement can be sufficiently achieved. But if the scalability of data capacity is considered later, use of the advanced 802.11 standard such as 802.11n and multiple signal paths between the HMS and MCS are necessary

  18. Performance Evaluation of Terrestrial Emergency Communication System in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Son, Gwang Sub; Kim, Chang Hwoi; Kang, Hyun Gook [KAERI, Daejeon (Korea, Republic of)

    2014-08-15

    The Fukushima accident induced by the great earthquake and tsunami reveals the vulnerability of I and C System. In the severe environment, the normal I and C system did not work properly and results in false information about the internal situation in NPP. Eventually the accident was not properly handled at the early stage. Therefore advanced emergency response system using a wireless channel is necessary to cope with the severe accident. In this paper, we introduce the ERS consisting of the HMS and MCS the ECS linking the HMS with MCS and the performance requirement of the ECS is analyzed. The ECS satisfying the requirement is designed conceptually and the performance of the ECS is evaluated through analysis and simulator. The terrestrial communication system is designed based on the IEEE 802.11. Analyzed performance results prove that the performance requirement can be sufficiently achieved. But if the scalability of data capacity is considered later, use of the advanced 802.11 standard such as 802.11n and multiple signal paths between the HMS and MCS are necessary.

  19. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  20. Evaluation of the environmental impact assessment system in Syria

    International Nuclear Information System (INIS)

    Haydar, F.; Pediaditi, K.

    2010-01-01

    Syria is a country experiencing rapid change, undergoing a process of political and governance decentralisation, opening its markets to the private sector, and experiencing a rise in infrastructure development. In light of these economic growth targeted changes, knowledge of the status and capacity of the Syrian EIA system to ensure environmental protection becomes of paramount importance. Syria first introduced EIA as a Draft Decree in 1995, which was not formally adopted until 2008. To date, no structured evaluation of Syria's EIA system has been conducted, a knowledge gap addressed through this paper. The research presented herein comprises a review and comparative evaluation of Syrian legislation and procedures, to the EU EIA Directive and World Bank Operational Directive, as well as a series of interviews with Syrian stakeholders involved in EIA implementation. The investigation concluded that the new EIA provisions provide a sound legal basis. From interviews however, it was ascertained that EIA implementation faces a number of barriers such as, a lack of EIA integration into existing decision making and licensing processes and persistent exclusion of public projects from EIA. A number of recommendations are proposed, perceived necessary for the enhancement of EIA implementation in Syria.

  1. Measures for simulator evaluation of a helicopter obstacle avoidance system

    Science.gov (United States)

    Demaio, Joe; Sharkey, Thomas J.; Kennedy, David; Hughes, Micheal; Meade, Perry

    1993-01-01

    The U.S. Army Aeroflightdynamics Directorate (AFDD) has developed a high-fidelity, full-mission simulation facility for the demonstration and evaluation of advanced helicopter mission equipment. The Crew Station Research and Development Facility (CSRDF) provides the capability to conduct one- or two-crew full-mission simulations in a state-of-the-art helicopter simulator. The CSRDF provides a realistic, full field-of-regard visual environment with simulation of state-of-the-art weapons, sensors, and flight control systems. We are using the CSRDF to evaluate the ability of an obstacle avoidance system (OASYS) to support low altitude flight in cluttered terrain using night vision goggles (NVG). The OASYS uses a laser radar to locate obstacles to safe flight in the aircraft's flight path. A major concern is the detection of wires, which can be difficult to see with NVG, but other obstacles--such as trees, poles or the ground--are also a concern. The OASYS symbology is presented to the pilot on a head-up display mounted on the NVG (NVG-HUD). The NVG-HUD presents head-stabilized symbology to the pilot while allowing him to view the image intensified, out-the-window scene through the HUD. Since interference with viewing through the display is a major concern, OASYS symbology must be designed to present usable obstacle clearance information with a minimum of clutter.

  2. A system for laparoscopic surgery ergonomics and skills evaluation.

    Science.gov (United States)

    Fanson, Richard; Khabbaz, Faezeh Heydari; Kapoor, Anil; Patriciu, Alexandru

    2011-07-01

    This article presents a system for tracking, recording, and analysis of instrument and surgeon's arm motion in minimally invasive surgeries. The captured trajectories can be objectively analyzed for both ergonomic assessment and skills evaluation. The system consists of two special infrared (IR) markers that are used for 6 degrees of freedom (DOF) laparoscopic instrument tracking and a set of 3DOF IR markers attached to elbows and shoulders. A compact IR camera tracks and records the markers during a standardized training task (eg, suturing). The instrument markers were purposely designed to provide good tracking while minimizing their volume. The accuracy of the instrument markers was evaluated showing a root mean square error of 0.61 mm, 1.0 mm, and 2.4 mm at distances from the camera of 0.5 m, 0.68 m, and 1 m respectively. Furthermore, some sample trajectories were recorded during an in-trainer suturing task. The Results section presents the values of basic skills metrics computed from the acquired data.

  3. Conceptual Model of Offshore Wind Environmental Risk Evaluation System

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Richard M.; Copping, Andrea E.; Van Cleve, Frances B.; Unwin, Stephen D.; Hamilton, Erin L.

    2010-06-01

    In this report we describe the development of the Environmental Risk Evaluation System (ERES), a risk-informed analytical process for estimating the environmental risks associated with the construction and operation of offshore wind energy generation projects. The development of ERES for offshore wind is closely allied to a concurrent process undertaken to examine environmental effects of marine and hydrokinetic (MHK) energy generation, although specific risk-relevant attributes will differ between the MHK and offshore wind domains. During FY10, a conceptual design of ERES for offshore wind will be developed. The offshore wind ERES mockup described in this report will provide a preview of the functionality of a fully developed risk evaluation system that will use risk assessment techniques to determine priority stressors on aquatic organisms and environments from specific technology aspects, identify key uncertainties underlying high-risk issues, compile a wide-range of data types in an innovative and flexible data organizing scheme, and inform planning and decision processes with a transparent and technically robust decision-support tool. A fully functional version of ERES for offshore wind will be developed in a subsequent phase of the project.

  4. Evaluation of Out-of-Autoclave (OOA epoxy system

    Directory of Open Access Journals (Sweden)

    Fernanda Guilherme

    Full Text Available Abstract Epoxy resins (EP usually cure in autoclave to minimize resin voids and to achieve the desired resin/fiber ratio. Cure parameters such as temperature, vacuum and pressure levels are controlled and monitored. Aiming time and cost optimization, new out-of-autoclave (OOA cure processes have been developed lately. This study evaluated the cure cycle and the effect of non-programmed interruptions in an OOA process. Fourier Transform Infrared spectroscopy (FT-IR results show similarities between the resin used and diglycidyl ether of bisphenol A (DGEBA and also that the curing system is composed of cyan and sulfur hardeners, codified in industry, as Components of #2511 Resin System. The cure cycle and its interruptions were simulated by dynamic-mechanical analysis (DMA. The samples obtained were evaluated by FT-IR and differential scanning calorimetry (DSC, whose results show that the degree of cure varying between 0.8 to 0.85 was achieved at 120 °C.

  5. An Automated, Image Processing System for Concrete Evaluation

    International Nuclear Information System (INIS)

    Baumgart, C.W.; Cave, S.P.; Linder, K.E.

    1998-01-01

    Allied Signal Federal Manufacturing ampersand Technologies (FM ampersand T) was asked to perform a proof-of-concept study for the Missouri Highway and Transportation Department (MHTD), Research Division, in June 1997. The goal of this proof-of-concept study was to ascertain if automated scanning and imaging techniques might be applied effectively to the problem of concrete evaluation. In the current evaluation process, a concrete sample core is manually scanned under a microscope. Voids (or air spaces) within the concrete are then detected visually by a human operator by incrementing the sample under the cross-hairs of a microscope and by counting the number of ''pixels'' which fall within a void. Automation of the scanning and image analysis processes is desired to improve the speed of the scanning process, to improve evaluation consistency, and to reduce operator fatigue. An initial, proof-of-concept image analysis approach was successfully developed and demonstrated using acquired black and white imagery of concrete samples. In this paper, the automated scanning and image capture system currently under development will be described and the image processing approach developed for the proof-of-concept study will be demonstrated. A development update and plans for future enhancements are also presented

  6. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  7. Design and Evaluation of Human System Interfaces (HSIs)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    In the safe operation of nuclear power plants and other complex process industries the performance of the control room crews plays an important role. In this respect a well-functioning and well-designed Human-System Interface (HSI) is crucial for safe and efficient operation of the plant. It is therefore essential that the design, development and evaluation of both control rooms and HSI-solutions are conducted in a well-structured way, applying sound human factors principles and guidelines in all phases of the HSI development process. Many nuclear power plants around the world are currently facing major modernisation of their control rooms. In this process computerised, screen-based HSIs replace old conventional operator interfaces. In new control rooms, both in the nuclear field and in other process industries, fully digital, screen-based control rooms are becoming the standard. It is therefore of particular importance to address the design and evaluation of screen-based HSIs in a systematic and consistent way in order to arrive at solutions which take proper advantage of the possibilities for improving operator support through the use of digital, screen-based HSIs, at the same time avoiding pitfalls and problems in the use of this technology. The Halden Reactor Project, in cooperation with the OECD Nuclear Energy Agency, organised an International Summer School on ''Design and Evaluation of Human-System Interfaces (HSIs)'' in Halden, Norway in the period August 25th - 29th, 2003. The Summer School addressed the different steps in design, development and evaluation of HSIs, and the human factors principles, standards and guidelines which should be followed in this process. The lectures comprised both theoretical background, as well as examples of good and bad HSI design, thereby providing practical advice in design and evaluation of operator interfaces and control room solutions to the participants in the Summer School. This CD contains the

  8. Design and Evaluation of Human System Interfaces (HSIs)

    International Nuclear Information System (INIS)

    2003-01-01

    In the safe operation of nuclear power plants and other complex process industries the performance of the control room crews plays an important role. In this respect a well-functioning and well-designed Human-System Interface (HSI) is crucial for safe and efficient operation of the plant. It is therefore essential that the design, development and evaluation of both control rooms and HSI-solutions are conducted in a well-structured way, applying sound human factors principles and guidelines in all phases of the HSI development process. Many nuclear power plants around the world are currently facing major modernisation of their control rooms. In this process computerised, screen-based HSIs replace old conventional operator interfaces. In new control rooms, both in the nuclear field and in other process industries, fully digital, screen-based control rooms are becoming the standard. It is therefore of particular importance to address the design and evaluation of screen-based HSIs in a systematic and consistent way in order to arrive at solutions which take proper advantage of the possibilities for improving operator support through the use of digital, screen-based HSIs, at the same time avoiding pitfalls and problems in the use of this technology. The Halden Reactor Project, in cooperation with the OECD Nuclear Energy Agency, organised an International Summer School on ''Design and Evaluation of Human-System Interfaces (HSIs)'' in Halden, Norway in the period August 25th - 29th, 2003. The Summer School addressed the different steps in design, development and evaluation of HSIs, and the human factors principles, standards and guidelines which should be followed in this process. The lectures comprised both theoretical background, as well as examples of good and bad HSI design, thereby providing practical advice in design and evaluation of operator interfaces and control room solutions to the participants in the Summer School. This CD contains the Proceedings of the

  9. Evaluating sustainability of truck weight regulations: A system dynamics view

    Directory of Open Access Journals (Sweden)

    Pei Liu

    2015-11-01

    Full Text Available Purpose: Targeting the problem of overload trucking in Highway Transportation of iron ore from Caofeidian to Tangshan (HTCT, this paper aims to assess long-term effects of alternative Truck Weight Regulation (TWR policies on sustainability of HTCT. Design/methodology/approach: A system dynamics model was established for policy evaluation. The model, composed of six interrelating modules, is able to simulate policies effects on trucking issues such as freight flow, truck traffic flow, pavement performance, highway transport capacity and trucking time, and further on the Cumulative Economic Cost (CEC including transport cost and time cost of freight owners and the Cumulative Social Cost (CSC including pavement maintenance cost, green house gas emission cost, air pollutants emission cost and traffic accidents cost, so the effects of TWR policies on sustainability of HTCT could be evaluated. Findings: According to different values of overload ratio which a TWR policy allows, alternative TWR policies are classified into three types, which are The Rigid Policy (TRP, The Moderate Policy (TMP and The Tolerant Policy (TTP. Results show that the best policy for sustainability of HTCT depends on the importance of CSC which is expected by the local government. To be specific, (1 if CSC is considered much less important than CEC, the local government should continue implementing the current TTP with the maximum overload ratio; (2 if CSC is considered much more important than CEC, then TRP is recommended; and (3 if CSC is considered slightly more important than CES, TMP with overload ratio of 80% is the best. Practical implications: Conclusions of this paper may help the local government design appropriate TWR policies to achieve sustainability of HTCT. Originality/value: To the best of our knowledge, this is the first effort to evaluate TWR policies on sustainability of regional freight transportation based on system dynamics modeling.

  10. Evaluation and proposal of improvement for the measurement system in ATLAS

    International Nuclear Information System (INIS)

    Cho, Dong Woo; Kim, Jong Rok; Park, Jun Kwon

    2007-03-01

    The project independently evaluated the validities and reliability of measurement system in ATLAS, then proposed plans to improve the measurement system from evaluated results. For this objectives, we evaluated the design, technical backgrounds, verifying data of measurement system in ATLAS. From this evaluation, we proposed plans for improvement on parts which need improvement

  11. 21 CFR 26.43 - Transmission of quality system evaluation reports.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Transmission of quality system evaluation reports... QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE... evaluation reports. Quality system evaluation reports covered by § 26.41 concerning products covered by this...

  12. Design, modeling, simulation and evaluation of a distributed energy system

    Science.gov (United States)

    Cultura, Ambrosio B., II

    This dissertation presents the design, modeling, simulation and evaluation of distributed energy resources (DER) consisting of photovoltaics (PV), wind turbines, batteries, a PEM fuel cell and supercapacitors. The distributed energy resources installed at UMass Lowell consist of the following: 2.5kW PV, 44kWhr lead acid batteries and 1500W, 500W & 300W wind turbines, which were installed before year 2000. Recently added to that are the following: 10.56 kW PV array, 2.4 kW wind turbine, 29 kWhr Lead acid batteries, a 1.2 kW PEM fuel cell and 4-140F supercapacitors. Each newly added energy resource has been designed, modeled, simulated and evaluated before its integration into the existing PV/Wind grid-connected system. The Mathematical and Simulink model of each system was derived and validated by comparing the simulated and experimental results. The Simulated results of energy generated from a 10.56kW PV system are in good agreement with the experimental results. A detailed electrical model of a 2.4kW wind turbine system equipped with a permanent magnet generator, diode rectifier, boost converter and inverter is presented. The analysis of the results demonstrates the effectiveness of the constructed simulink model, and can be used to predict the performance of the wind turbine. It was observed that a PEM fuel cell has a very fast response to load changes. Moreover, the model has validated the actual operation of the PEM fuel cell, showing that the simulated results in Matlab Simulink are consistent with the experimental results. The equivalent mathematical equation, derived from an electrical model of the supercapacitor, is used to simulate its voltage response. The model is completely capable of simulating its voltage behavior, and can predict the charge time and discharge time of voltages on the supercapacitor. The bi-directional dc-dc converter was designed in order to connect the 48V battery bank storage to the 24V battery bank storage. This connection was

  13. PET evaluation of the dopamine system of the human brain.

    Science.gov (United States)

    Volkow, N D; Fowler, J S; Gatley, S J; Logan, J; Wang, G J; Ding, Y S; Dewey, S

    1996-07-01

    strategies developed to evaluate the various elements of the dopamine system in the human brain with PET and their applications to clinical research.

  14. Cytotoxicity Evaluation of Tear Substitutes Using in vitro System

    Directory of Open Access Journals (Sweden)

    O. I. Aleksandrova

    2017-01-01

    Full Text Available Objective. The objective of the study is to evaluate in vitro the cytotoxic effect of different moisture eye drops (containing or without preservatives on the epithelial cells of the conjunctiva and the cornea.Materials and methods. The objects of the study are moisture eye drops: Hylabak®, Thealoz®, Sistane Ultra®, Kationorm®, Oftolik®, Artelak® Balance, Optiv®. As test systems there were used the transformed cells of normal eye tissues: constant conjunctiva transformed cell lines (Chang Conjunctiva, Clone 1-5c-4 and the human cornea (HCEC. The cytotoxicity of the “artificial tears” was assessed by the viability of cells, cultured in substratum containing the solutions of the objects at concentrations 1, 5 and 10%. Cell viability was assessed by their morphology and metabolic activity.Results. The most sensitive to the investigated eye drops is considered to be the test system based on human corneal cells. Four of the seven investigated eye drops (Artelak® Balance, Optiv®, Kationorm®, Oftolik® at a concentration of 10% (by volume of the substratum showed a high degree of toxicity for cornea cells. Eyedrops Sistane Ultra® had moderate toxic effect on the cells of the cornea and conjunctiva at concentration 5 and 10% (by volume. Hylabak® and Thealoz® in this concentrations did not have any cytotoxic effect on the cells of all test system and showed the best results in the research. The most toxic of all cell types were eye drops Oftolik® and Artelak® balance.Conclusion. A direct relationship between the concentration of drug in culture medium and cell cytotoxicity was investigated. Eye drops Hylabak® and Thealoz®, that do not contain in its composition a preservative, had no cytotoxic effect on the cells of both test systems at all concentrations used. The lowest toxic effect of the test had eye drop Sistane Ultra® containing “soft” preservative Poliquad®. Among the “artificial tears”, the greatest toxic effect on

  15. Performance evaluation of communication software systems for distributed computing

    Science.gov (United States)

    Fatoohi, R. A.

    1997-09-01

    In recent years there has been an increasing interest in object-oriented distributed computing since it is better equipped to deal with complex systems while providing extensibility, maintainability and reusability. At the same time, several new high-speed network technologies have emerged for local and wide area networks. However, the performance of networking software is not improving as fast as the networking hardware and the workstation microprocessors. This paper gives an overview and evaluates the performance of the Common Object Request Broker Architecture (CORBA) standard in a distributed computing environment at NASA Ames Research Center. The environment consists of two testbeds of SGI workstations connected by four networks: Ethernet, FDDI, HiPPI and ATM. The performance results for three communication software systems are presented, analysed and compared. These systems are: BSD socket programming interface, IONA's Orbix, an implementation of the CORBA specification and the PVM message passing library. The results show that high-level communication interfaces, such as CORBA and PVM, can achieve reasonable performance under certain conditions.

  16. Evaluation of Critical Parameters to Improve Slope Drainage System

    Directory of Open Access Journals (Sweden)

    Yong Weng Long

    2017-01-01

    Full Text Available This study focuses on identifying and evaluating critical parameters of various drainage configurations, arrangement, and filter which affect the efficiency of water draining system in slopes. There are a total of seven experiments with different types of homogeneous soil, drainage envelope, filter material, and quantity of pipes performed utilizing a model box with a dimension of 0.8 m × 0.8 m × 0.6 m. The pipes were orientated at 5 degrees from the horizontal. Rainfall event was introduced via a rainfall simulator with rainfall intensity of 434.1 mm/h. From the experiments performed, the expected outcomes when utilizing double pipes and geotextile as envelope filter were verified in this study. The results obtained from these experiments were reviewed and compared with Chapter 14 “Subsurface Drainage Systems” of DID’s Irrigation and Agricultural Drainage Manual of Malaysia and the European standard. It is recommended that the pipe installed in the slope could be wrapped with geotextile and in tandem with application of granular filter to minimize clogging without affecting the water discharge rate. Terzaghi’s filter criteria could be followed closely when deciding on new materials to act as aggregate filter. A caging system could be introduced as it could maintain the integrity of the drainage system and could ease installation.

  17. Evaluation of the learning management system using students' perceptions.

    Science.gov (United States)

    Sayfouri, Nasrin

    2016-01-01

    Background: Learning Management System (LMS) is a web-based system designed to support teaching and learning at an institution. The capabilities of any LMS are required to be evaluated to detect the room for improvement. This study aimed at discovering the students' perceptions of the functions of the LMS at Iran University of Medical Sciences (IUMS). Methods: This qualitative study included 15 students of two master programs of Biostatistics and Medical Librarianship during the fall semester of 2015. The participants were asked to write down their perceptions of the experiences they had while using the LMS and classify them based on two categories of "Advantages and Drawbacks". Framework Analysis technique was used to analyze the views. Results: The themes emerging from the 'Advantages' included advantages for the students, advantages for the teachers, and advantages for both; however, those from the 'Drawbacks' were found to be technical and nontechnical problems. Conclusion: The major debated points in the comments comprised the students' positive accounts of the Forum section, and their complaints of the frequent glitches recurring in the system as well as some constructive problems such as inefficient tools for typing in English. Some all-inclusive inferences concerning the methodology of the study have also been pointed out in the final section.

  18. [Evaluation of the Oran university hospital information system].

    Science.gov (United States)

    Chougrani, Saada; Ouhadj, Salah; Agag, Fouzia

    2013-01-01

    Oran university hospital has been operating since 2010. It is a public institution that must assess the resources required to achieve institutional goals integrated into the strategic objectives defined in the hospital development project. Implementation of this project could be supported, among other things, by a strong and efficient hospital information system. Three investigations were conducted: 1- evaluation of the hospital information system, 2- assessment of the quality of the hospital discharge summary reports, 3- assessment of the quality of medical records. The six components of the hospital information system (resources, indicators, sources, management, quality and dissemination and use of data) were clearly present but not satisfactory with a score ranging from 25 to 50% of the total score. The scores by component were as follows: 36% for resources, 37% for indicators, 42% for patient records, 19% for data management and 27% for the dissemination of information. The overall completeness of medical records was 85.2%. Completeness by group of variables gave the following results: 66% for medical information, 54% for the patient's stay and 38% for information relating to the patient's discharge. Hospital discharge summary reports were available in 59.8% of cases, but were blank in 4% of cases. The critical variable, the principal diagnosis was found in 51% of cases. The correct principal diagnosis rate was 33.3%. The deficiencies observed for content and data management raise real questions concerning data management at Oran university hospital as part of a real managerial approach.

  19. Evaluation of the improvement suggestion system in a nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Carnaval, Joao Paulo Rodrigues; Moraes, Geice Almeida, E-mail: joaocarnaval@inb.gov.br, E-mail: geice@inb.gov.br [Industrias Nucleares do Brasil S.A (INB), Resende, RJ (Brazil)

    2017-11-01

    This work evaluated methods for processing improvement suggestions of a nuclear factory, with the intention to verify those which best fits to the company purposes. Two methods for processing improvement suggestions were applied in the studied organization. The first one was guided to the processing suggestions by specific independent sectors of the company and the second one was conducted to the processing of suggestions by a multidisciplinary team. It has been concluded that a multidisciplinary team focused on research and development would be the best option to the implementation of improvement suggestions and technological innovation on this facility, instead of multi sector processing which revealed to be excessive bureaucratic before the expected goals. This study can be used by nuclear facilities to optimize an existing system of improvements analysis or even guide them for the implantation of a new one. It is more significant for the companies certified on ISO and OHSAS standards for the quality management, environmental and safety and occupational health systems which requires that the continuous improvement must exist and to be demonstrated. But it is also relevant for nuclear plants aiming to implement an Integrated Management System certified on ISO Standards. (author)

  20. The Federated Satellite Systems paradigm: Concept and business case evaluation

    Science.gov (United States)

    Golkar, Alessandro; Lluch i Cruz, Ignasi

    2015-06-01

    This paper defines the paradigm of Federated Satellite Systems (FSS) as a novel distributed space systems architecture. FSS are networks of spacecraft trading previously inefficiently allocated and unused resources such as downlink bandwidth, storage, processing power, and instrument time. FSS holds the promise to enhance cost-effectiveness, performance and reliability of existing and future space missions, by networking different missions and effectively creating a pool of resources to exchange between participants in the federation. This paper introduces and describes the FSS paradigm, and develops an approach integrating mission analysis and economic assessments to evaluate the feasibility of the business case of FSS. The approach is demonstrated on a case study on opportunities enabled by FSS to enhance space exploration programs, with particular reference to the International Space Station. The application of the proposed methodology shows that the FSS concept is potentially able to create large commercial markets of in-space resources, by providing the technical platform to offer the opportunity for spacecraft to share or make use of unused resources within their orbital neighborhood. It is shown how the concept is beneficial to satellite operators, space agencies, and other stakeholders of the space industry to more flexibly interoperate space systems as a portfolio of assets, allowing unprecedented collaboration among heterogeneous types of missions.