WorldWideScience

Sample records for system postflight evaluation

  1. Development of Testing Methodologies to Evaluate Postflight Locomotor Performance

    Science.gov (United States)

    Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Warren, L. E.; Bloomberg, J. J.

    2006-01-01

    Crewmembers experience locomotor and postural instabilities during ambulation on Earth following their return from space flight. Gait training programs designed to facilitate recovery of locomotor function following a transition to a gravitational environment need to be accompanied by relevant assessment methodologies to evaluate their efficacy. The goal of this paper is to demonstrate the operational validity of two tests of locomotor function that were used to evaluate performance after long duration space flight missions on the International Space Station (ISS).

  2. Post-Flight Back Pain Following International Space Station Missions: Evaluation of Spaceflight Risk Factors

    Science.gov (United States)

    Laughlin, M. S.; Murray, J. D.; Wear, M. L.; Van Baalen, M.

    2016-01-01

    INTRODUCTION Back pain during spaceflight has often been attributed to the lengthening of the spinal column due to the absence of gravity during both short and long-duration missions. Upon landing and re-adaptation to gravity, the spinal column reverts back to its original length thereby causing some individuals to experience pain and muscular spasms, while others experience no ill effects. With International Space Station (ISS) missions, cases of back pain and injury are more common post-flight, but little is known about the potential risk factors. Thus, the purpose of this project was to perform an initial evaluation of reported post-flight back pain and injury cases to relevant spaceflight risk factors in United States astronauts that have completed an ISS mission. METHODS All US astronauts who completed an ISS mission between Expeditions (EXP) 1 and 41 (2000-2015) were included in this evaluation. Forty-five astronauts (36 males and 9 females) completed 50 ISS missions during the study time period, as 5 astronauts completed 2 ISS missions. Researchers queried medical records of the 45 astronauts for occurrences of back pain and injury. A case was defined as any reported event of back pain or injury to the cervical, thoracic, lumbar, sacral, or coccyx spine regions. Data sources for the cases included the Flight Medicine Clinic's electronic medical record; Astronaut Strength, Conditioning and Rehabilitation electronic documentation; the Private Medical Conference tool; and the Space Medicine Operations Team records. Post-flight cases were classified as an early case if reported within 45 days of landing (R + 45) or a late case if reported from R + 46 to R + 365 days after landing (R + 1y). Risk factors in the astronaut population for back pain include age, sex, prior military service, and prior history of back pain. Additionally, spaceflight specific risk factors such as type of landing vehicle and onboard exercise countermeasures were included to evaluate their

  3. Post-Flight Data Analysis Tool

    Science.gov (United States)

    George, Marina

    2018-01-01

    A software tool that facilitates the retrieval and analysis of post-flight data. This allows our team and other teams to effectively and efficiently analyze and evaluate post-flight data in order to certify commercial providers.

  4. Post-Flight Back Pain Following International Space Station Missions: Evaluation of Spaceflight Risk Factors

    Science.gov (United States)

    Laughlin, Mitzi S.; Murray, Jocelyn D.; Wear, Mary L.; Van Baalen, Mary

    2016-01-01

    Back pain during spaceflight has often been attributed to the lengthening of the spinal column due to the absence of gravity during both short and long-duration missions. Upon landing and re-adaptation to gravity, the spinal column reverts back to its original length thereby causing some individuals to experience pain and muscular spasms, while others experience no ill effects. With International Space Station (ISS) missions, cases of back pain and injury are more common post-flight, but little is known about the potential risk factors.

  5. Computer program for post-flight evaluation of the control surface response for an attitude controlled missile

    Science.gov (United States)

    Knauber, R. N.

    1982-01-01

    A FORTRAN IV coded computer program is presented for post-flight analysis of a missile's control surface response. It includes preprocessing of digitized telemetry data for time lags, biases, non-linear calibration changes and filtering. Measurements include autopilot attitude rate and displacement gyro output and four control surface deflections. Simple first order lags are assumed for the pitch, yaw and roll axes of control. Each actuator is also assumed to be represented by a first order lag. Mixing of pitch, yaw and roll commands to four control surfaces is assumed. A pseudo-inverse technique is used to obtain the pitch, yaw and roll components from the four measured deflections. This program has been used for over 10 years on the NASA/SCOUT launch vehicle for post-flight analysis and was helpful in detecting incipient actuator stall due to excessive hinge moments. The program is currently set up for a CDC CYBER 175 computer system. It requires 34K words of memory and contains 675 cards. A sample problem presented herein including the optional plotting requires eleven (11) seconds of central processor time.

  6. Post-Flight Evaluation of PICA and PICA-X - Comparisons of the Stardust SRC and Space-X Dragon 1 Forebody Heatshield Materials

    Science.gov (United States)

    Stackpoole, M.; Kao, D.; Qu, V.; Gonzales, G.

    2013-01-01

    Phenolic Impregnated Carbon Ablator (PICA) was developed at NASA Ames Research Center. As a thermal protection material, PICA has the advantages of being able to withstand high heat fluxes with a relatively low density. This ablative material was used as the forebody heat shield material for the Stardust sample return capsule, which re-entered the Earths atmosphere in 2006. Based on PICA, SpaceX developed a variant, PICA-X, and used it as the heat shield material for its Dragon spacecraft, which successfully orbited the Earth and re-entered the atmosphere during the COTS Demo Flight 1 in 2010. Post-flight analysis was previously performed on the Stardust PICA heat shield material. Similarly, a near-stagnation core was obtained from the post-flight Dragon 1 heat shield, which was retrieved from the Pacific Ocean. Materials testing and analyses were performed on the core to evaluate its ablation performance and post-flight properties. Comparisons between PICA and PICA-X are made where applicable. Stardust and Dragon offer rare opportunities to evaluate materials post-flight - this data is beneficial in understanding material performance and also improves modeling capabilities.

  7. Pre- and post-flight radiation performance evaluation of the space GPS receiver (SGR)

    International Nuclear Information System (INIS)

    Oldfield, M.K.; Underwood, C.I.; Unwin, M.J.; Asenek, V.; Harboe-Sorensen, R.

    1999-01-01

    SSTL (Survey Satellite Technology Ltd), in collaboration with ESA/ESTEC, recently developed a state-of-the-art low cost GPS (Global Positioning System) receiver payload for use on small satellites. The space GPS Receiver (SGR), will be flown on the TiungSAT-1 micro-satellite, UoSAT-12 mini-satellite and ESA's PROBA satellite. The SGR payload is currently flying on the TMSAT micro-satellite in low Earth orbit (LEO) and has carried out autonomous on-board positioning whilst also providing an experimental test-bed for evaluating spacecraft attitude determination algorithms. In order to reduce development time and costs, the SGR consists solely of industry standard COTS (commercial off-the-shelf) devices. This paper describes the ground-based radiation testing of several payload-critical COTS devices used in the SGR payload and describes its on-orbit performance. (authors)

  8. Post-Flight Microbial Analysis of Samples from the International Space Station Water Recovery System and Oxygen Generation System

    Science.gov (United States)

    Birmele, Michele N.

    2011-01-01

    The Regenerative, Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS) includes the the Water Recovery System (WRS) and the Oxygen Generation System (OGS). The WRS consists of a Urine Processor Assembly (UPA) and Water Processor Assembly (WPA). This report describes microbial characterization of wastewater and surface samples collected from the WRS and OGS subsystems, returned to KSC, JSC, and MSFC on consecutive shuttle flights (STS-129 and STS-130) in 2009-10. STS-129 returned two filters that contained fluid samples from the WPA Waste Tank Orbital Recovery Unit (ORU), one from the waste tank and the other from the ISS humidity condensate. Direct count by microscopic enumeration revealed 8.38 x 104 cells per mL in the humidity condensate sample, but none of those cells were recoverable on solid agar media. In contrast, 3.32 x lOs cells per mL were measured from a surface swab of the WRS waste tank, including viable bacteria and fungi recovered after S12 days of incubation on solid agar media. Based on rDNA sequencing and phenotypic characterization, a fungus recovered from the filter was determined to be Lecythophora mutabilis. The bacterial isolate was identified by rDNA sequence data to be Methylobacterium radiotolerans. Additional UPA subsystem samples were returned on STS-130 for analysis. Both liquid and solid samples were collected from the Russian urine container (EDV), Distillation Assembly (DA) and Recycle Filter Tank Assembly (RFTA) for post-flight analysis. The bacterium Pseudomonas aeruginosa and fungus Chaetomium brasiliense were isolated from the EDV samples. No viable bacteria or fungi were recovered from RFTA brine samples (N= 6), but multiple samples (N = 11) from the DA and RFTA were found to contain fungal and bacterial cells. Many recovered cells have been identified to genus by rDNA sequencing and carbon source utilization profiling (BiOLOG Gen III). The presence of viable bacteria and fungi from WRS

  9. HYDICE postflight data processing

    Science.gov (United States)

    Aldrich, William S.; Kappus, Mary E.; Resmini, Ronald G.; Mitchell, Peter A.

    1996-06-01

    The hyperspectral digital imagery collection experiment (HYDICE) sensor records instrument counts for scene data, in-flight spectral and radiometric calibration sequences, and dark current levels onto an AMPEX DCRsi data tape. Following flight, the HYDICE ground data processing subsystem (GDPS) transforms selected scene data from digital numbers (DN) to calibrated radiance levels at the sensor aperture. This processing includes: dark current correction, spectral and radiometric calibration, conversion to radiance, and replacement of bad detector elements. A description of the algorithms for post-flight data processing is presented. A brief analysis of the original radiometric calibration procedure is given, along with a description of the development of the modified procedure currently used. Example data collected during the 1995 flight season, but uncorrected and processed, are shown to demonstrate the removal of apparent sensor artifacts (e.g., non-uniformities in detector response over the array) as a result of this transformation.

  10. STS-69 postflight presentation

    Science.gov (United States)

    1995-10-01

    A postflight conference of the STS-69 mission is presented. The flightcrew ('The Dog Team') consisted of Cmdr. David Walker, Pilot Kenneth Cockrell, Payload Cmdr. James Voss, and Mission Specialists James Newman and Michael Gernhardt. The mission's primary objective was the deployment and retrieval of the SPARTAN-201 satellite, which investigated the interaction between the Sun and it's solar wind. Other secondary experiments and shuttle payloads included the Wake Shield Facility (WSF), which grew several layers of semiconductor films, the International Extreme Ultraviolet Hitchhiker (IEH-1), the Capillary Pumped Loop-2/Gas Bridge Assembly (CAPL-2/GBA), several Get Away Specials (GAS) experiments, the Electrolysis Performance Improvement Concept Study (EPICS), the Thermal Energy Storage (TES-2) experiment, the Commercial Generic Bioprocessing Apparatus-7 (CGBA-7), the National Institutes of Health-Cells 4 (NIH-C4) experiment, and the Biological Research in Canister-6 (BRIC-6) experiment. Earth views consisted of Saudi Arabia water wells, uncommon vortices over Oman, the Amazon River, the Bahamas, Somalia, a sunset over the Earth's horizon, and two hurricanes, Luis and Marilyn.

  11. Perseus Post-flight

    Science.gov (United States)

    1991-01-01

    Crew members check out the Perseus proof-of-concept vehicle on Rogers Dry Lake, adjacent to the Dryden Flight Research Center, Edwards, California, after a test flight in 1991. Perseus B is a remotely piloted aircraft developed as a design-performance testbed under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. Perseus is one of several flight vehicles involved in the ERAST project. A piston engine, propeller-powered aircraft, Perseus was designed and built by Aurora Flight Sciences Corporation, Manassas, Virginia. The objectives of Perseus B's ERAST flight tests have been to reach and maintain horizontal flight above altitudes of 60,000 feet and demonstrate the capability to fly missions lasting from 8 to 24 hours, depending on payload and altitude requirements. The Perseus B aircraft established an unofficial altitude record for a single-engine, propeller-driven, remotely piloted aircraft on June 27, 1998. It reached an altitude of 60,280 feet. In 1999, several modifications were made to the Perseus aircraft including engine, avionics, and flight-control-system improvements. These improvements were evaluated in a series of operational readiness and test missions at the Dryden Flight Research Center, Edwards, California. Perseus is a high-wing monoplane with a conventional tail design. Its narrow, straight, high-aspect-ratio wing is mounted atop the fuselage. The aircraft is pusher-designed with the propeller mounted in the rear. This design allows for interchangeable scientific-instrument payloads to be placed in the forward fuselage. The design also allows for unobstructed airflow to the sensors and other devices mounted in the payload compartment. The Perseus B that underwent test and development in 1999 was the third generation of the Perseus design, which began with the Perseus Proof-Of-Concept aircraft. Perseus was initially developed as part of NASA's Small High-Altitude Science Aircraft (SHASA) program, which later evolved

  12. Representation of the Physiological Factors Contributing to Postflight Changes in Functional Performance Using Motion Analysis Software

    Science.gov (United States)

    Parks, Kelsey

    2010-01-01

    Astronauts experience changes in multiple physiological systems due to exposure to the microgravity conditions of space flight. To understand how changes in physiological function influence functional performance, a testing procedure has been developed that evaluates both astronaut postflight functional performance and related physiological changes. Astronauts complete seven functional and physiological tests. The objective of this project is to use motion tracking and digitizing software to visually display the postflight decrement in the functional performance of the astronauts. The motion analysis software will be used to digitize astronaut data videos into stick figure videos to represent the astronauts as they perform the Functional Tasks Tests. This project will benefit NASA by allowing NASA scientists to present data of their neurological studies without revealing the identities of the astronauts.

  13. Physiological Factors Contributing to Postflight Changes in Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Feedback, D. L.; Feiverson, A. H.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; Reschke, M. F.; Ryder, J.; Spiering, B. A.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objectives of the FTT are to: Develop a set of functional tasks that represent critical mission tasks for Constellation. Determine the ability to perform these tasks after flight. Identify the key physiological factors that contribute to functional decrements. Use this information to develop targeted countermeasures. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers will perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data will be collected on R+0 (Shuttle only), R

  14. Defining the Physiological Factors that Contribute to Postflight Changes in Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Arzeno, N.; Buxton, R.; Feiveson, A. H.; Kofman, I.; Lawrence, E.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objective of the FTT is to identify the key underlying physiological factors that contribute to performance of functional tests that are representative of critical mission tasks. This study will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor

  15. Evaluation of Galvanic Vestibular Stimulation System

    Science.gov (United States)

    Kofman, I. S.; Warren, E.; DeSoto, R.; Moroney, G.; Chastain, J.; De Dios, Y. E.; Gadd, N.; Taylor, L.; Peters, B. T.; Allen, E.; hide

    2017-01-01

    ) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

  16. Heart rate variability and short duration spaceflight: relationship to post-flight orthostatic intolerance

    Directory of Open Access Journals (Sweden)

    Blaber Andrew P

    2004-04-01

    Full Text Available Abstract Background Upon return from space many astronauts experience symptoms of orthostatic intolerance. Research has implicated altered autonomic cardiovascular regulation due to spaceflight with further evidence to suggest that there might be pre-flight autonomic indicators of post-flight orthostatic intolerance. We used heart rate variability (HRV to determine whether autonomic regulation of the heart in astronauts who did or did not experience post-flight orthostatic intolerance was different pre-flight and/or was differentially affected by short duration (8 – 16 days spaceflight. HRV data from ten-minute stand tests collected from the 29 astronauts 10 days pre-flight, on landing day and three days post-flight were analysed using coarse graining spectral analysis. From the total power (PTOT, the harmonic component was extracted and divided into high (PHI: >0.15 Hz and low (PLO: = 0.15 Hz frequency power regions. Given the distribution of autonomic nervous system activity with frequency at the sinus node, PHI/PTOT was used as an indicator of parasympathetic activity; PLO/PTOT as an indicator of sympathetic activity; and, PLO/PHI as an estimate of sympathovagal balance. Results Twenty-one astronauts were classified as finishers, and eight as non-finishers, based on their ability to remain standing for 10 minutes on landing day. Pre-flight, non-finishers had a higher supine PHI/PTOT than finishers. Supine PHI/PTOT was the same pre-flight and on landing day in the finishers; whereas, in the non-finishers it was reduced. The ratio PLO/PHI was lower in non-finishers compared to finishers and was unaffected by spaceflight. Pre-flight, both finishers and non-finishers had similar supine values of PLO/PTOT, which increased from supine to stand. Following spaceflight, only the finishers had an increase in PLO/PTOT from supine to stand. Conclusions Both finishers and non-finishers had an increase in sympathetic activity with stand on pre

  17. Functional Task Test: 1. Sensorimotor changes Associated with Postflight Alterations in Astronaut Functional Task Performance

    Science.gov (United States)

    Bloomberg, J. J.; Arzeno, N. H.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Platts, S. H.; Peters, B. T.; hide

    2011-01-01

    Space flight is known to cause alterations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. This presentation will focus on the sensorimotor contributions to postflight functional performance.

  18. Orion Exploration Flight Test Post-Flight Inspection and Analysis

    Science.gov (United States)

    Miller, J. E.; Berger, E. L.; Bohl, W. E.; Christiansen, E. L.; Davis, B. A.; Deighton, K. D.; Enriquez, P. A.; Garcia, M. A.; Hyde, J. L.; Oliveras, O. M.

    2017-01-01

    The principal mechanism for developing orbital debris environment models, is to make observations of larger pieces of debris in the range of several centimeters and greater using radar and optical techniques. For particles that are smaller than this threshold, breakup and migration models of particles to returned surfaces in lower orbit are relied upon to quantify the flux. This reliance on models to derive spatial densities of particles that are of critical importance to spacecraft make the unique nature of the EFT-1's return surface a valuable metric. To this end detailed post-flight inspections have been performed of the returned EFT-1 backshell, and the inspections identified six candidate impact sites that were not present during the pre-flight inspections. This paper describes the post-flight analysis efforts to characterize the EFT-1 mission craters. This effort included ground based testing to understand small particle impact craters in the thermal protection material, the pre- and post-flight inspection, the crater analysis using optical, X-ray computed tomography (CT) and scanning electron microscope (SEM) techniques, and numerical simulations.

  19. Evaluation Use in Evaluation Systems

    DEFF Research Database (Denmark)

    Højlund, Steven

    2014-01-01

    This article investigates the European Union’s evaluation system and its conduciveness to evaluation use. Taking the European Commission’s LIFE programme as its case, the article makes an empirical contribution to an emerging focus in the literature on the importance of organization...... and institutions when analyzing evaluation use. By focusing on the European Union’s evaluation system the article finds that evaluation use mainly takes place in the European Commission and less so in the European Parliament and the European Council. The main explanatory factors enabling evaluation use relate...... to the system’s formalization of evaluation implementation and use; these factors ensure evaluation quality, timeliness and capacity in the Commission. At the same time, however, the system’s formalization also impedes evaluation use, reducing the direct influence of evaluations on policy-making and effectively...

  20. IRVE-II Post-Flight Trajectory Reconstruction

    Science.gov (United States)

    O'Keefe, Stephen A.; Bose, David M.

    2010-01-01

    NASA s Inflatable Re-entry Vehicle Experiment (IRVE) II successfully demonstrated an inflatable aerodynamic decelerator after being launched aboard a sounding rocket from Wallops Flight Facility (WFF). Preliminary day of flight data compared well with pre-flight Monte Carlo analysis, and a more complete trajectory reconstruction performed with an Extended Kalman Filter (EKF) approach followed. The reconstructed trajectory and comparisons to an attitude solution provided by NASA Sounding Rocket Operations Contract (NSROC) personnel at WFF are presented. Additional comparisons are made between the reconstructed trajectory and pre and post-flight Monte Carlo trajectory predictions. Alternative observations of the trajectory are summarized which leverage flight accelerometer measurements, the pre-flight aerodynamic database, and on-board flight video. Finally, analysis of the payload separation and aeroshell deployment events are presented. The flight trajectory is reconstructed to fidelity sufficient to assess overall project objectives related to flight dynamics and overall, IRVE-II flight dynamics are in line with expectations

  1. Orion Exploration Flight Test-1 Post-Flight Navigation Performance Assessment Relative to the Best Estimated Trajectory

    Science.gov (United States)

    Gay, Robert S.; Holt, Greg N.; Zanetti, Renato

    2016-01-01

    This paper details the post-flight navigation performance assessment of the Orion Exploration Flight Test-1 (EFT-1). Results of each flight phase are presented: Ground Align, Ascent, Orbit, and Entry Descent and Landing. This study examines the on-board Kalman Filter uncertainty along with state deviations relative to the Best Estimated Trajectory (BET). Overall the results show that the Orion Navigation System performed as well or better than expected. Specifically, the Global Positioning System (GPS) measurement availability was significantly better than anticipated at high altitudes. In addition, attitude estimation via processing GPS measurements along with Inertial Measurement Unit (IMU) data performed very well and maintained good attitude throughout the mission.

  2. Covariance evaluation system

    International Nuclear Information System (INIS)

    Kawano, Toshihiko; Shibata, Keiichi.

    1997-09-01

    A covariance evaluation system for the evaluated nuclear data library was established. The parameter estimation method and the least squares method with a spline function are used to generate the covariance data. Uncertainties of nuclear reaction model parameters are estimated from experimental data uncertainties, then the covariance of the evaluated cross sections is calculated by means of error propagation. Computer programs ELIESE-3, EGNASH4, ECIS, and CASTHY are used. Covariances of 238 U reaction cross sections were calculated with this system. (author)

  3. Assessment of Postflight Locomotor Performance Utilizing a Test of Functional Mobility: Strategic and Adaptive Responses

    Science.gov (United States)

    Warren, L. E.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Ruttley, T. M.; Bloomberg, J. J.

    2006-01-01

    have further analyzed the FMT data to characterize strategic and adaptive components during the postflight readaptation period. Crewmembers walked at a preferred pace through an obstacle course set up on a base of 10 cm thick medium density foam (Sunmate Foam, Dynamic Systems, Inc., Leicester, NC). The 6.0m X 4.0m course consisted of several pylons made of foam; a Styrofoam barrier 46.0cm high that crewmembers stepped over; and a portal constructed of two Styrofoam blocks, each 31cm high, with a horizontal bar covered by foam and suspended from the ceiling which was adjusted to the height of the crewmember s shoulder. The portal required crewmembers to bend at the waist and step over a barrier simultaneously. All obstacles were lightweight, soft and easily knocked over. Crewmembers were instructed to walk through the course as quickly and as safely as possible without touching any of the objects on the course. This task was performed three times in the clockwise direction and three times in the counterclockwise direction that was randomly chosen. The dependent measures for each trial were: time to complete the course (seconds) and the number of obstacles touched or knocked down. For each crewmember, the time to complete each FMT trial from postflight days 1, 2, 4, 7 and 25 were further analyzed. A single logarithmic curve using a least squares calculation was fit through these data to produce a single comprehensive curve (macro). This macro curve composed of data spanning 25 days, illustrates the re-adaptive learning function over the longer time scale term. Additionally, logarithmic curves were fit to the 6 data trials within each individual post flight test day to produce 5 separate daily curves. These micro curves, produced from data obtained over the course of minutes, illustrates the strategic learning function exhibited over a relative shorter time scale. The macro curve for all subjects exhibited adaptive motor learning patterns over the 25 day period. Howev, 9

  4. The OTOLITH Experiment - Assessment of Otolith Function During Postflight Re-adaption

    Science.gov (United States)

    Clarke, A. H.; Wood, S. J.; Schoenfeld, U.

    2010-01-01

    The ongoing "Otolith" experiment is designed to comprehensively assess the otolith function during the re-adaptation phase after spaceflight. The novel protocol includes unilateral testing of each of the two otolith organs the utricle and the saccule. To assess utricle function, the otolith-ocular response (OOR) and the subjective visual vertical (SVV) are measured during unilateral centrifugation, which permits independent stimulation of the right and left ear. Measurement of the unilateral otolith-ocular response (uOOR) yields information on the response behaviour of the right and left peripheral utricles, whereas the SVV reflects the behaviour of the entire pathway from the peripheral otolith receptors to the vestibular cortex. Thus, by comparative evaluation of the results from the two tests, the degree of peripheral versus central adaptation during the post-flight period can be determined. To assess unilateral saccule function, vestibular evoked myogenic potentials (VEMP) are recorded. Since the saccules are predominantly aligned to gravity, and interplay with the antigravity muscles, it is hypothesised that these potentials shall be altered after spaceflight. To date the study has been conducted with 5 of a planned 8 short-flight Shuttle astronauts. Preliminary results will be discussed together with those from clinical studies of dizziness patients, where the same test protocol is employed. ACKNOWLEDGEMENT This work is supported by the German Aerospace Center (Grant DLR W130729) and is conducted under the auspices of ESA, in cooperation with NASA.

  5. Flight feeding systems design and evaluation. Supplement 1: Production guides. [for the Apollo food system

    Science.gov (United States)

    1973-01-01

    The requirements for processing, packaging, testing, and shipment of foods selected for use in the Apollo food system are presented. Specific foodstuffs chosen from the following categories are discussed: (1) soups; (2) juices; (3) breads; (4) meat and poultry products; (5) fruits and nuts; (6) desserts; and (7) beverages. Food procurement for the mobile quarantine facility and for Apollo preflight and postflight activities is also discussed.

  6. Nuclear data evaluation method and evaluation system

    International Nuclear Information System (INIS)

    Liu Tingjin

    1995-01-01

    The evaluation methods and Nuclear Data Evaluation System have been developed in China. A new version of the system has been established on Micro-VAX2 computer, which is supported by IAEA under the technology assistance program. The flow chart of Chinese Nuclear Data Evaluation System is shown out. For last ten years, the main efforts have been put on the double differential cross section, covariance data and evaluated data library validation. The developed evaluation method and Chinese Nuclear Data Evaluation System have been widely used at CNDC and in Chinese Nuclear Data Network for CENDL. (1 tab., 15 figs.)

  7. MODULAR CONSTRUCTION SYSTEM EVALUATION

    International Nuclear Information System (INIS)

    Gillespie, S.

    2002-01-01

    The purpose of this study is to respond to U.S. Department of Energy (DOE) Technical Direction Letter (TDL) 02-003 (Waisley 2001), which directs Bechtel SAIC Company, LLC (BSC) to complete a design study to recommend repository design options to support receipt and/or emplacement of any or all of the following: commercial spent nuclear fuel (CSNF), high-level radioactive waste (HLW), DOE-managed spent nuclear fuel (DSNF) (including naval spent nuclear fuel [SNF]), and immobilized plutonium (if available), as soon as practicable, but no later than 2010. From the possible design options, a recommended approach will be determined for further evaluation to support the preliminary design of the repository. This study integrates the results of the repository Design Evolution Study (Rowe 2002) with supporting studies concerning national transportation options (BSC 2002b) and Nevada transportation options (Gehner 2002). The repository Design Evolution Study documents the processes used to reevaluate the design, construction, operation, and cost of the repository in response to TDL 02-003 (Waisley 2001), and to determine possible repository conceptual design options. The transportation studies evaluate the national and Nevada transportation options that support the repository conceptual design options. An evaluation methodology was established, based on Program-level requirements developed for the study in reference BSC 2001a, to allow the repository and system design options to be evaluated on a consistent basis. The transportation options and the design components were integrated into system design implementation options, which were evaluated using receipt and emplacement scenarios. The scenarios tested the ability of the design concept to adapt to changes in funding, waste receipt rate, and Nevada rail transportation availability. The results of the evaluation (in terms of system throughput, cost, and schedule) were then compared to the Program-level requirements, and

  8. Process evaluation distributed system

    Science.gov (United States)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  9. Correlation of Space Shuttle Landing Performance with Post-Flight Cardiovascular Dysfunction

    Science.gov (United States)

    McCluskey, R.

    2004-01-01

    Introduction: Microgravity induces cardiovascular adaptations resulting in orthostatic intolerance on re-exposure to normal gravity. Orthostasis could interfere with performance of complex tasks during the re-entry phase of Shuttle landings. This study correlated measures of Shuttle landing performance with post-flight indicators of orthostatic intolerance. Methods: Relevant Shuttle landing performance parameters routinely recorded at touchdown by NASA included downrange and crossrange distances, airspeed, and vertical speed. Measures of cardiovascular changes were calculated from operational stand tests performed in the immediate post-flight period on mission commanders from STS-41 to STS-66. Stand test data analyzed included maximum standing heart rate, mean increase in maximum heart rate, minimum standing systolic blood pressure, and mean decrease in standing systolic blood pressure. Pearson correlation coefficients were calculated with the null hypothesis that there was no statistically significant linear correlation between stand test results and Shuttle landing performance. A correlation coefficient? 0.5 with a pcorrelations between landing performance and measures of post-flight cardiovascular dysfunction. Discussion: There was no evidence that post-flight cardiovascular stand test data correlated with Shuttle landing performance. This implies that variations in landing performance were not due to space flight-induced orthostatic intolerance.

  10. Human Performance Evaluation System

    International Nuclear Information System (INIS)

    Hardwick, R.J. Jr.

    1985-01-01

    Operating nuclear power plants requires high standards of performance, extensive training and responsive management. Despite our best efforts inappropriate human actions do occur, but they can be managed. An extensive review of License Event Reports (LERs) was conducted which indicated continual inadequacy in human performance and in evaluation of root causes. Of some 31,000 LERs, about 5,000 or 16% were directly attributable to inappropriate actions. A recent analysis of 87 Significant Event Reports (issued by INPO in 1983) identified inappropriate actions as being the most frequent root cause (44% of the total). A more recent analysis of SERs issued in 1983 and 1984 indicate that 52% of the root causes were attributed to human performance. The Human Performance Evaluation System (HPES) is a comprehensive, coordinated utility/industry system for evaluating and reporting human performance situtations. HPES is a result of the realization that current reporting system provide limited treatment of human performance and rarely provide adequate information about root causes of inappropriate actions by individuals. The HPES was implemented to identify and eliminate root causes of inappropriate actions

  11. Safety significance evaluation system

    International Nuclear Information System (INIS)

    Lew, B.S.; Yee, D.; Brewer, W.K.; Quattro, P.J.; Kirby, K.D.

    1991-01-01

    This paper reports that the Pacific Gas and Electric Company (PG and E), in cooperation with ABZ, Incorporated and Science Applications International Corporation (SAIC), investigated the use of artificial intelligence-based programming techniques to assist utility personnel in regulatory compliance problems. The result of this investigation is that artificial intelligence-based programming techniques can successfully be applied to this problem. To demonstrate this, a general methodology was developed and several prototype systems based on this methodology were developed. The prototypes address U.S. Nuclear Regulatory Commission (NRC) event reportability requirements, technical specification compliance based on plant equipment status, and quality assurance assistance. This collection of prototype modules is named the safety significance evaluation system

  12. Preflight and postflight microbiological results from 25 space shuttle crews

    Science.gov (United States)

    Pierson, Duane L.; Bassinger, Virginia J.; Molina, Thomas C.; Gunter, Emelie G.; Groves, Theron O.; Cioletti, Louis J.; Mishra, S. K.

    1993-01-01

    Clinical-microbiological investigations are an important aspect of the crew health stabilization program. To ensure that space crews have neither active nor latent infections, clinical specimens, including throat and nasal swabs and urine samples, are collected at 10 days (L-10) and 2days (L-2) before launch, and immediately after landing (L+0). All samples are examined for the presence of bacteria and fungi. In addition, fecal samples are collected at L-10 and examined for bacteria, fungi and parasites. This paper describes clinical-microbiological findings from 144 astronauts participating in 25 Space Shuttle missions spanning Space Transportation System (STS)-26 to STS-50. The spectrum of microbiological findings from the specimens included 25 bacterial and 11 fungal species. Among the bacteria isolated most frequently were Staphylococcus aureus, Enterobacter aerogenes, Enterococcus faecalis, Escherichia coli, Proteus mirabilis and Streptococcus agalactiae. Candida albicans was the most frequently isolated fungal pathogen.

  13. Pervious Pavement System Evaluation

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, grade...

  14. Evaluation Systems, Ethics, and Development Evaluation

    Science.gov (United States)

    Thomas, Vinod

    2010-01-01

    After some 65 years of international development assistance, it is still difficult to show the effectiveness of aid in ways that are fully convincing. In part, this reflects inadequacies in the evaluation systems of the bilateral, multilateral, and global organizations that provide official development aid. Underlying these weaknesses often are a…

  15. Back pain in space and post-flight spine injury: Mechanisms and countermeasure development

    Science.gov (United States)

    Sayson, Jojo V.; Lotz, Jeffrey; Parazynski, Scott; Hargens, Alan R.

    2013-05-01

    During spaceflight many astronauts experience moderate to severe lumbar pain and deconditioning of paraspinal muscles. There is also a significant incidence of herniated nucleus pulposus (HNP) in astronauts post-flight being most prevalent in cervical discs. Relief of in-flight lumbar back pain is facilitated by assuming a knee-to-chest position. The pathogenesis of lumbar back pain during spaceflight is most likely discogenic and somatic referred (from the sinuvertebral nerves) due to supra-physiologic swelling of the lumbar intervertebral discs (IVDs) due to removal of gravitational compressive loads in microgravity. The knee-to-chest position may reduce lumbar back pain by redistributing stresses through compressive loading to the IVDs, possibly reducing disc volume by fluid outflow across IVD endplates. IVD stress redistribution may reduce Type IV mechanoreceptor nerve impulse propagation in the annulus fibrosus and vertebral endplate resulting in centrally mediated pain inhibition during spinal flexion. Countermeasures for lumbar back pain may include in-flight use of: (1) an axial compression harness to prevent excessive IVD expansion and spinal column elongation; (2) the use of an adjustable pulley exercise developed to prevent atrophy of spine muscle stabilisers; and (3) other exercises that provide Earth-like annular stress with low-load repetitive active spine rotation movements. The overall objective of these countermeasures is to promote IVD health and to prevent degenerative changes that may lead to HNPs post-flight. In response to "NASA's Critical Path Roadmap Risks and Questions" regarding disc injury and higher incidence of HNPs after space flight (Integrated Research Plan Gap-B4), future studies will incorporate pre- and post-flight imaging of International Space Station long-duration crew members to investigate mechanisms of lumbar back pain as well as degeneration and damage to spinal structures. Quantitative results on morphological, biochemical

  16. Autogenic-feedback training: A potential treatment for post-flight orthostatic intolerance in aerospace crews

    Science.gov (United States)

    Cowings, Patricia S.; Toscano, William B.; Miller, Neil E.; Pickering, Thomas G.; Shapiro, David

    1993-01-01

    Postflight orthostatic intolerance was identified as a serious biomedical problem associated with long duration exposure to microgravity in space. High priority was given to the development of countermeasures for this disorder which are both effective and practical. A considerable body of clinical research demonstrated that people can be taught to increase their own blood pressure voluntarily and that this is an effective treatment for chronic orthostatic intolerance in paralyzed patients. The present pilot study was designed to examine the feasibility of adding training in control of blood pressure to an existing preflight training program designed to facilitate astronaut adaptation to microgravity. Using an operant conditioning procedure, Autogenic-Feedback Training (AFT), three men and two women participated in four to nine (15-30 training sessions). At the end of training, the average increase in systolic and diastolic pressure, as well as mean arterial pressures that the subjects made, ranged between 20 and 5O mmHg under both supine and 45 deg head-up tilt conditions. These findings suggest that AFT may be a useful alternative treatment or supplement to existing approaches for preventing postflight orthostatic intolerance. Further, the use of operant conditioning methods for training cardiovascular responses may contribute to the general understanding of the mechanisms of orthostatic intolerance.

  17. Integrated Main Propulsion System Performance Reconstruction Process/Models

    Science.gov (United States)

    Lopez, Eduardo; Elliott, Katie; Snell, Steven; Evans, Michael

    2013-01-01

    The Integrated Main Propulsion System (MPS) Performance Reconstruction process provides the MPS post-flight data files needed for postflight reporting to the project integration management and key customers to verify flight performance. This process/model was used as the baseline for the currently ongoing Space Launch System (SLS) work. The process utilizes several methodologies, including multiple software programs, to model integrated propulsion system performance through space shuttle ascent. It is used to evaluate integrated propulsion systems, including propellant tanks, feed systems, rocket engine, and pressurization systems performance throughout ascent based on flight pressure and temperature data. The latest revision incorporates new methods based on main engine power balance model updates to model higher mixture ratio operation at lower engine power levels.

  18. MTA Computer Based Evaluation System.

    Science.gov (United States)

    Brenner, Lisa P.; And Others

    The MTA PLATO-based evaluation system, which has been implemented by a consortium of schools of medical technology, is designed to be general-purpose, modular, data-driven, and interactive, and to accommodate other national and local item banks. The system provides a comprehensive interactive item-banking system in conjunction with online student…

  19. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  20. USAF Weapon System Evaluation Program

    National Research Council Canada - National Science Library

    1999-01-01

    During this task period, Schafer Corporation provided engineering services and analysis to the USAF at Eglin AFB, Florida in direct support of the USAF Air-to-Surface Weapon System Evaluation Program (WSEP...

  1. Control Evaluation Information System Savings

    Directory of Open Access Journals (Sweden)

    Eddy Sutedjo

    2011-05-01

    Full Text Available The purpose of this research is to evaluate the control of information system savings in the banking and to identify the weaknesses and problem happened in those saving systems. Research method used are book studies by collecting data and information needed and field studies by interview, observation, questioner, and checklist using COBIT method as a standard to assess the information system control of the company. The expected result about the evaluation result that show in the problem happened and recommendation given as the evaluation report and to give a view about the control done by the company. Conclusion took from this research that this banking company has met standards although some weaknesses still exists in the system.Index Terms - Control Information System, Savings

  2. Evaluation of EIT system performance.

    Science.gov (United States)

    Yasin, Mamatjan; Böhm, Stephan; Gaggero, Pascal O; Adler, Andy

    2011-07-01

    An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach to evaluate the performance of the EIT systems. The system to be tested is connected to a saline phantom in which calibrated contrasting test objects are systematically positioned using a position controller. A set of evaluation parameters are proposed which characterize (i) data and image noise, (ii) data accuracy, (iii) detectability of single contrasts and distinguishability of multiple contrasts, and (iv) accuracy of reconstructed image (amplitude, resolution, position and ringing). Using this approach, we evaluate three different EIT systems and illustrate the use of these tools to evaluate and compare performance. In order to facilitate the use of this approach, all details of the phantom, test objects and position controller design are made publicly available including the source code of the evaluation and reporting software.

  3. "System evaluates system": method for evaluating the efficiency of IS

    Directory of Open Access Journals (Sweden)

    Dita Blazkova

    2016-10-01

    Full Text Available In paper I deal with the possible solution of evaluating the efficiency of information systems in companies. The large number of existing methods used to address the efficiency of information systems is dependent on the subjective responses of the user that may distort output evaluation. Therefore, I propose a method that eliminates the subjective opinion of a user as the primary data source. Applications, which I suggests as part of the method, collects relevant data. In this paper I describe the application in detail. This is a follow-on program on any system that runs parallel with it. The program automatically collects data for evaluation. Data include mainly time data, positions the mouse cursor, printScreens, i-grams of previous, etc. I propose a method of evaluation of the data, which identifies the degree of the friendliness of the information system to the user. Thus, the output of the method is the conclusion whether users, who work with the information system, can handle effectively work with it.

  4. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the seismic module of the CARES system (computer analysis for rapid evaluation of structures). This system was developed to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structural in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the seismic module in particular. The development of the seismic modules of the CARES system is based on an approach which incorporates major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities

  5. Reliability evaluation of power systems

    CERN Document Server

    Billinton, Roy

    1996-01-01

    The Second Edition of this well-received textbook presents over a decade of new research in power system reliability-while maintaining the general concept, structure, and style of the original volume. This edition features new chapters on the growing areas of Monte Carlo simulation and reliability economics. In addition, chapters cover the latest developments in techniques and their application to real problems. The text also explores the progress occurring in the structure, planning, and operation of real power systems due to changing ownership, regulation, and access. This work serves as a companion volume to Reliability Evaluation of Engineering Systems: Second Edition (1992).

  6. Mobility Models for Systems Evaluation

    Science.gov (United States)

    Musolesi, Mirco; Mascolo, Cecilia

    Mobility models are used to simulate and evaluate the performance of mobile wireless systems and the algorithms and protocols at the basis of them. The definition of realistic mobility models is one of the most critical and, at the same time, difficult aspects of the simulation of applications and systems designed for mobile environments. There are essentially two possible types of mobility patterns that can be used to evaluate mobile network protocols and algorithms by means of simulations: traces and synthetic models [130]. Traces are obtained by means of measurements of deployed systems and usually consist of logs of connectivity or location information, whereas synthetic models are mathematical models, such as sets of equations, which try to capture the movement of the devices.

  7. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  8. The Evaluation of Computer Systems

    Directory of Open Access Journals (Sweden)

    Cezar Octavian Mihalcescu

    2007-01-01

    Full Text Available Generally, the evaluation of the computersystems is especially interesting at present from severalpoints of view: computer-related, managerial,sociological etc. The reasons for this extended interest arerepresented by the fact that IT becomes increasinglyimportant for reaching the goals of an organization, ingeneral, and the strategic ones in particular. Evaluationmeans the estimation or determination of value, and issynonymous with measuring the value. Evaluating theeconomic value of Computer Systems should be studiedat three levels: individually, at a group level and at anorganization level.

  9. Plant operator performance evaluation system

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Fukuda, Mitsuko; Kubota, Ryuji.

    1989-01-01

    A plant operator performance evaluation system to analyze plant operation records during accident training and to identify and classify operator errors has been developed for the purpose of supporting realization of a training and education system for plant operators. A knowledge engineering technique was applied to evaluation of operator behavior by both even-based and symptom-based procedures, in various situations including event transition due to multiple failures or operational errors. The system classifies the identified errors as to their single and double types based on Swain's error classification and the error levels reflecting Rasmussen's cognitive level, and it also evaluates the effect of errors on plant state and then classifies error influence, using 'knowledge for phenomena and operations', as represented by frames. It has additional functions for analysis of error statistics and knowledge acquisition support of 'knowledge for operations'. The system was applied to a training analysis for a scram event in a BWR plant, and its error analysis function was confirmed to be effective by operational experts. (author)

  10. High Pressure Electrolyzer System Evaluation

    Science.gov (United States)

    Prokopius, Kevin; Coloza, Anthony

    2010-01-01

    This report documents the continuing efforts to evaluate the operational state of a high pressure PEM based electrolyzer located at the NASA Glenn Research Center. This electrolyzer is a prototype system built by General Electric and refurbished by Hamilton Standard (now named Hamilton Sunstrand). It is capable of producing hydrogen and oxygen at an output pressure of 3000 psi. The electrolyzer has been in storage for a number of years. Evaluation and testing was performed to determine the state of the electrolyzer and provide an estimate of the cost for refurbishment. Pressure testing was performed using nitrogen gas through the oxygen ports to ascertain the status of the internal membranes and seals. It was determined that the integrity of the electrolyzer stack was good as there were no appreciable leaks in the membranes or seals within the stack. In addition to the integrity testing, an itemized list and part cost estimate was produced for the components of the electrolyzer system. An evaluation of the system s present state and an estimate of the cost to bring it back to operational status was also produced.

  11. Post-flight trajectory reconstruction of suborbital free-flyers using GPS raw data

    Science.gov (United States)

    Ivchenko, N.; Yuan, Y.; Linden, E.

    2017-08-01

    This paper describes the reconstruction of postflight trajectories of suborbital free flying units by using logged GPS raw data. We took the reconstruction as a global least squares optimization problem, using both the pseudo-range and Doppler observables, and solved it by using the trust-region-reflective algorithm, which enabled navigational solutions of high accuracy. The code tracking was implemented with a large number of correlators and least squares curve fitting, in order to improve the precision of the code start times, while a more conventional phased lock loop was used for Doppler tracking. We proposed a weighting scheme to account for fast signal strength variation due to free-flier fast rotation, and a penalty for jerk to achieve a smooth solution. We applied these methods to flight data of two suborbital free flying units launched on REXUS 12 sounding rocket, reconstructing the trajectory, receiver clock error and wind up rates. The trajectory exhibits a parabola with the apogee around 80 km, and the velocity profile shows the details of payloadwobbling. The wind up rates obtained match the measurements from onboard angular rate sensors.

  12. Post-flight trajectory reconstruction of suborbital free-flyers using GPS raw data

    Directory of Open Access Journals (Sweden)

    Ivchenko N.

    2017-08-01

    Full Text Available This paper describes the reconstruction of postflight trajectories of suborbital free flying units by using logged GPS raw data. We took the reconstruction as a global least squares optimization problem, using both the pseudo-range and Doppler observables, and solved it by using the trust-region-reflective algorithm, which enabled navigational solutions of high accuracy. The code tracking was implemented with a large number of correlators and least squares curve fitting, in order to improve the precision of the code start times, while a more conventional phased lock loop was used for Doppler tracking. We proposed a weighting scheme to account for fast signal strength variation due to free-flier fast rotation, and a penalty for jerk to achieve a smooth solution. We applied these methods to flight data of two suborbital free flying units launched on REXUS 12 sounding rocket, reconstructing the trajectory, receiver clock error and wind up rates. The trajectory exhibits a parabola with the apogee around 80 km, and the velocity profile shows the details of payloadwobbling. The wind up rates obtained match the measurements from onboard angular rate sensors.

  13. Post-Flight Characterization of Samples for the MISSE-7 Spacesuit Fabric Exposure Experiment

    Science.gov (United States)

    Gaier, James R.; Waters, Deborah L.; Jaworski, Donald A.; McCue, Terry R.; Folz, Angela; Baldwin, Sammantha; Clark, Gregory W.; Batman, Brittany; Bruce, John

    2012-01-01

    Six samples of pristine and dust-abraded outer layer spacesuit fabrics were included in the Materials International Space Station Experiment-7, in which they were exposed to the wake side low Earth orbit environment (LEO) on the International Space Station (ISS) for 18 months in order to determine whether abrasion by lunar dust increases radiation degradation. The fabric samples were characterized using optical microscopy, field emission scanning electron microscopy, and tensile testing before and after exposure on the ISS. Comparison of pre- and post-flight characterizations showed that wake side LEO environment darkened and reddened all six fabrics, increasing their integrated solar absorptance by 7 to 38 percent. There was a decrease in the ultimate tensile strength and elongation to failure of lunar dust abraded Apollo spacesuit fibers by a factor of four and increased the elastic modulus by a factor of two. The severity of the degradation of the fabric samples over this short exposure time demonstrates the necessity to find ways to prevent or mitigate radiation damage to spacesuits when planning extended missions to the Moon.

  14. Management information systems software evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Tunisi, N.; Ghazzawi, A.; Gruyaert, F.; Clarke, D. [Saudi Aramco, Dhahran (Saudi Arabia). Process and Control Systems Dept.

    1995-11-01

    In November 1993, Saudi Aramco management endorsed a proposal to coordinate the development of the Management Information Systems (MISs) of four concurrent projects for its facilities Controls Modernization Program. The affected projects were the Ras Tanura Refinery Upgrade Project, the Abqaiq Plant Controls Modernization and the Shedgum and Uthmaniyah Gas plants Control Upgrade Projects. All of these projects had a significant requirement of MISs in their scope. Under the leadership of the Process and Control Systems Department, and MIS Coordination Team was formed with representatives of several departments. An MIS Applications Evaluation procedure was developed based on the Kepner Tregoe Decisions Analysis Process and general questionnaires were sent to over a hundred potential Vendors. The applications were divided into several categories, such as: Data Capture and Historization, Human User Interface, Trending, Reporting, Graphic Displays, Data Reconciliation, Statistical Analysis, Expert Systems, Maintenance Applications, Document Management and Operations Planning and Scheduling. For each of the MIS Application areas, detailed follow-up questionnaires were used to short list the candidate products. In May and June 1994, selected Vendors were invited to Saudi Arabia for an Exhibition which was open to all Saudi Aramco employees. In conjunction with this, the Vendors were subjected to a rigorous product testing exercise by independent teams of testers. The paper will describe the methods used and the lessons learned in this extensive software evaluation phase, which was a first for Saudi Aramco.

  15. Management information systems software evaluation

    International Nuclear Information System (INIS)

    Al-Tunisi, N.; Ghazzawi, A.; Gruyaert, F.; Clarke, D.

    1995-01-01

    In November 1993, Saudi Aramco management endorsed a proposal to coordinate the development of the Management Information Systems (MISs) of four concurrent projects for its facilities Controls Modernization Program. The affected projects were the Ras Tanura Refinery Upgrade Project, the Abqaiq Plant Controls Modernization and the Shedgum and Uthmaniyah Gas plants Control Upgrade Projects. All of these projects had a significant requirement of MISs in their scope. Under the leadership of the Process and Control Systems Department, and MIS Coordination Team was formed with representatives of several departments. An MIS Applications Evaluation procedure was developed based on the Kepner Tregoe Decisions Analysis Process and general questionnaires were sent to over a hundred potential Vendors. The applications were divided into several categories, such as: Data Capture and Historization, Human User Interface, Trending, Reporting, Graphic Displays, Data Reconciliation, Statistical Analysis, Expert Systems, Maintenance Applications, Document Management and Operations Planning and Scheduling. For each of the MIS Application areas, detailed follow-up questionnaires were used to short list the candidate products. In May and June 1994, selected Vendors were invited to Saudi Arabia for an Exhibition which was open to all Saudi Aramco employees. In conjunction with this, the Vendors were subjected to a rigorous product testing exercise by independent teams of testers. The paper will describe the methods used and the lessons learned in this extensive software evaluation phase, which was a first for Saudi Aramco

  16. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the Seismic Module of the CARES system (Computer Analysis for Rapid Evaluation of Structures). This system was developed by Brookhaven National Laboratory (BNL) for the US Nuclear Regulatory Commission to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structured in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the Seismic Module in particular. The development of the Seismic Module of the CARES system is based on an approach which incorporates all major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities. It has been designed with user friendly features and it allows for interactive manipulation of various analysis phases during the seismic design process. The capabilities of the seismic module include (a) generation of artificial time histories compatible with given design ground response spectra, (b) development of Power Spectral Density (PSD) functions associated with the seismic input, (c) deconvolution analysis using vertically propagating shear waves through a given soil profile, and (d) development of in-structure response spectra or corresponding PSD's. It should be pointed out that these types of analyses can also be performed individually by using available computer codes such as FLUSH, SAP, etc. The uniqueness of the CARES, however, lies on its ability to perform all required phases of the seismic analysis in an integrated manner. 5 refs., 6 figs

  17. Evaluation of the COGITO system

    DEFF Research Database (Denmark)

    Andersen, V.; Andersen, H.H.K.

    2002-01-01

    -site and for benefiting efficiently from the functionality of the site. In order to make the report a stand-alone report, it contains an introduction including 'Study of end-user needs and behaviour' exposing problemsconcerning e-commerce in general (taken from the D6.1), and a brief review of the objectives......This report covers the deliverable D7.2 of the COGITO project. It presents the evaluation of an 'intelligent' agent integrated into an e-commerce system. The aim of the agent is to support the user partly through direct communication and partly by guidinghim/her for navigating the web...

  18. Efficiency Evaluation of Energy Systems

    CERN Document Server

    Kanoğlu, Mehmet; Dinçer, İbrahim

    2012-01-01

    Efficiency is one of the most frequently used terms in thermodynamics, and it indicates how well an energy conversion or process is accomplished. Efficiency is also one of the most frequently misused terms in thermodynamics and is often a source of misunderstanding. This is because efficiency is often used without being properly defined first. This book intends to provide a comprehensive evaluation of various efficiencies used for energy transfer and conversion systems including steady-flow energy devices (turbines, compressors, pumps, nozzles, heat exchangers, etc.), various power plants, cogeneration plants, and refrigeration systems. The book will cover first-law (energy based) and second-law (exergy based) efficiencies and provide a comprehensive understanding of their implications. It will help minimize the widespread misuse of efficiencies among students and researchers in energy field by using an intuitive and unified approach for defining efficiencies. The book will be particularly useful for a clear ...

  19. Investigation of Post-Flight Solid Rocket Booster Thermal Protection System

    Science.gov (United States)

    Nelson, Linda A.

    2006-01-01

    After every Shuttle mission, the Solid Rocket Boosters (SRBs) are recovered and observed for missing material. Most of the SRB is covered with a cork-based thermal protection material (MCC-l). After the most recent shuttle mission, STS-114, the forward section of the booster appeared to have been impacted during flight. The darkened fracture surfaces indicated that this might have occurred early in flight. The scope of the analysis included microscopic observations to assess the degree of heat effects and locate evidence of the impact source as well as chemical analysis of the fracture surfaces and recovered foreign material using Fourier Transform Infrared Spectroscopy and Scanning Electron Microscopy/Energy Dispersive Spectroscopy. The amount of heat effects and presence of soot products on the fracture surface indicated that the material was impacted prior to SRB re-entry into the atmosphere. Fragments of graphite fibers found on these fracture surfaces were traced to slag inside the Solid Rocket Motor (SRM) that forms during flight as the propellant is spent and is ejected throughout the descent of the SRB after separation. The direction of the impact mark matches with the likely trajectory of SRBs tumbling prior to re-entry.

  20. Fission yield data evaluation system FYDES

    International Nuclear Information System (INIS)

    Liu Tingjin

    1998-01-01

    Taking account of some features of fission yield data, to do the fission yield data evaluation conveniently, a fission yield data evaluation system FYDES has been developed for last two years. Outline of the system, data retrieval and data table standardization, data correction codes, data averaging code, simultaneous evaluation code and data fit programs were introduced

  1. A Potential Treatment for Post-Flight Orthostatic Intolerance in Aero-Space Crews: Autogenic-Feedback Training

    Science.gov (United States)

    Cowings, P. S.; Toscano, W. B.; Miller, N. E.; Pickering, T. G.; Shapiro, D.

    1994-01-01

    Postflight orthostatic intolerance has been identified as a serious biomedical problem associated with long duration exposure to microgravity in space. High priority has been given to the development of countermeasures for this disorder which are both effective and practical. A considerable body of clinical research has demonstrated that people can be taught to increase their own blood pressure voluntarily and that this is an effective treatment for chronic Orthostatic intolerance in paralyzed patients. The present pilot study was designed to examine the feasibility of adding training in control of blood pressure to an existing preflight training program designed to facilitate astronaut adaptation to microgravity. Using in operant conditioning procedure, Autogenic-Feedback Training (AFT), three men and two women participated in four to nine (15-30 training sessions). At the end of training ranged between 20 and 50 mm Hg under both supine and 450 head-up tilt conditions. These findings suggest that AFT may be a useful alternative treatment or supplement to existing approaches for preventing postflight Orthostatic intolerance. Further, the use of operant conditioning methods for training cardiovascular responses may contribute to the general understanding of the mechanisms of orthostatic intolerance.

  2. Evaluation of mobile systems: an integrative framework.

    NARCIS (Netherlands)

    Högler, T.; Versendaal, J.; Batenburg, R.

    2015-01-01

    This work presents an integrative framework for the evaluation of mobile systems. In comparison to stationary systems, mobile systems have a bundle of specific singularities that should be considered for evaluation. Further analysis of existing approaches clarifies that an integrative approach for

  3. Pervious Pavement System Evaluation- Abstract

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, gra...

  4. Performance Evaluation Of Behavioral Biometric Systems

    OpenAIRE

    Cherifi , Fouad; Hemery , Baptiste; Giot , Romain; Pasquet , Marc; Rosenberger , Christophe

    2009-01-01

    We present in this chapter an overview of techniques for the performance evaluation of behavioral biometric systems. The BioAPI standard that defines the architecture of a biometric system is presented in the first part of the chapter... The general methodology for the evaluation of biometric systems is given including statistical metrics, definition of benchmark databases and subjective evaluation. These considerations rely with the ISO/IEC19795-1 standard describing the biometric performanc...

  5. Evaluating safety management system implementation

    International Nuclear Information System (INIS)

    Preuss, M.

    2009-01-01

    Canada is committed to not only maintaining, but also improving upon our record of having one of the safest aviation systems in the world. The development, implementation and maintenance of safety management systems is a significant step towards improving safety performance. Canada is considered a world leader in this area and we are fully engaged in implementation. By integrating risk management systems and business practices, the aviation industry stands to gain better safety performance with less regulatory intervention. These are important steps towards improving safety and enhancing the public's confidence in the safety of Canada's aviation system. (author)

  6. Evaluating neural networks and artificial intelligence systems

    Science.gov (United States)

    Alberts, David S.

    1994-02-01

    Systems have no intrinsic value in and of themselves, but rather derive value from the contributions they make to the missions, decisions, and tasks they are intended to support. The estimation of the cost-effectiveness of systems is a prerequisite for rational planning, budgeting, and investment documents. Neural network and expert system applications, although similar in their incorporation of a significant amount of decision-making capability, differ from each other in ways that affect the manner in which they can be evaluated. Both these types of systems are, by definition, evolutionary systems, which also impacts their evaluation. This paper discusses key aspects of neural network and expert system applications and their impact on the evaluation process. A practical approach or methodology for evaluating a certain class of expert systems that are particularly difficult to measure using traditional evaluation approaches is presented.

  7. Measurement and evaluation systems for NPP commissioning

    International Nuclear Information System (INIS)

    Elko, Marek

    2006-01-01

    Standard core monitoring and information systems are designed with an emphasis on normal operation of nuclear power plant. Their purpose is to provide necessary support for reactor operators and other operating personnel during the fuel cycle. After each fuel reloading, and to the larger extent during the plant commissioning, a variety of start-up tests need to be carried out and evaluated. Sampling periods, accuracy and communication delays of standard systems are not always suitable for test performance and evaluation. For technical and safety reasons, the access to standard monitoring and information systems is very limited. Non-Standard Measurement and Evaluation Systems are highly specialized devices designed with an emphasis on start-up tests performance and evaluation. They are capable of high frequency sampling, processing and communication of hundreds of technological signals with required accuracy and low communication delay. All technological signals needed for the test performance and evaluation are collected from various systems, concentrated in one system and fully accessible to a test leader, a reactor physicist or other users. In addition, Non-Standard Measurement and Evaluation Systems can perform other tasks like data storing and presentation, data distribution to other systems or external computers via network, reactivity calculations, etc. Structure of such systems can vary, but generally it is a mixture of two basic concepts: a mobile system and a stationary system. A basic description of hardware structure and software equipment of Non-Standard Measurement and Evaluation Systems is given in the paper (Authors)

  8. Evaluating a Skills Management System

    International Nuclear Information System (INIS)

    Largier, A.

    2013-01-01

    In order to anticipate the large number of people due to retire in the next few years, and to optimize the workforce contribution, IRSN (Institute for radiation protection and nuclear safety) is setting up skill management. This poster presents the IRSN's skill management system. The skill management system is based on a 4 step approach: -) identifying and listing the necessary skills, -) assessing the skills available, -) defining and setting up solutions: training, recruitment, out-sourcing), and -) feedback about the efficiency of the system. It appears that it is important to take into account the way the organization considers individual ability in order to favour collective proficiency

  9. Adversary characterization for security system evaluation

    International Nuclear Information System (INIS)

    Suber, L.A. Jr.

    1976-04-01

    Evaluation of security systems effectiveness requires a definition of adversary capabilities, but an objective basis for such a definition has been lacking. A system of adversary attributes is proposed in which any desired adversary may be synthesized by selection of the appropriate level of capability from each attribute or category. In use, the synthesized adversaries will be pitted against a security system in an evaluation model, thus allowing comparison of other adversary or security system configurations

  10. Modular system design and evaluation

    CERN Document Server

    Levin, Mark Sh

    2015-01-01

    This book examines seven key combinatorial engineering frameworks (composite schemes consisting of algorithms and/or interactive procedures) for hierarchical modular (composite) systems. These frameworks are based on combinatorial optimization problems (e.g., knapsack problem, multiple choice problem, assignment problem, morphological clique problem), with the author’s version of morphological design approach – Hierarchical Morphological Multicritieria Design (HMMD) – providing a conceptual lens with which to elucidate the examples discussed. This approach is based on ordinal estimates of design alternatives for systems parts/components, however, the book also puts forward an original version of HMMD that is based on new interval multiset estimates for the design alternatives with special attention paid to the aggregation of modular solutions (system versions). The second part of ‘Modular System Design and Evaluation’ provides ten information technology case studies that enriches understanding of th...

  11. Dependability Evaluation of Advanced Diverse Protection System

    International Nuclear Information System (INIS)

    Oh, Yang Gyun; Lee, Yoon Hee; Sohn, Se Do; Baek, Seung Min; Lee, Sang Jeong

    2014-01-01

    For the mitigation of anticipated transients without scram (ATWS) as well as common cause failure (CCF) within the plant protection system (PPS) and the emergency safety feature . component control system (ESF-CCS), the diverse protection system (DPS) has been designed by KEPCO Engineering and Construction Company. Recently KEPCO E and C has developed the advanced diverse protection system (ADPS), which has four redundant channels, in an attempt to enhance a fault-tolerant capability of the system. For the evaluation of overall system improvement effects of the ADPS compared with the DPS, the dependability evaluation results are described herein. For all dependability attributes, this paper suggests a practical dependability evaluation method which uses quantitative dependability scores and indices. An overall dependability evaluation index (DEI) for the ADPS is evaluated with the average value of reliability/ security/maintainability/safety indices (i.e., RID, SID, MID, and SID') for dependability. The evaluation results show that the DEI value of ADPS can be improved by approximately 23% compared with that of the DPS, thanks to its fault-tolerant system architecture, software design changes, and external interface design features. Several suggestions have been made, in this paper, of an overall quantitative dependability evaluation method for the nuclear instrumentation and control (I and C) systems including the DPS and ADPS, and the usefulness of dependability evaluation on nuclear I and C systems has been confirmed

  12. Road Anomalies Detection System Evaluation.

    Science.gov (United States)

    Silva, Nuno; Shah, Vaibhav; Soares, João; Rodrigues, Helena

    2018-06-21

    Anomalies on road pavement cause discomfort to drivers and passengers, and may cause mechanical failure or even accidents. Governments spend millions of Euros every year on road maintenance, often causing traffic jams and congestion on urban roads on a daily basis. This paper analyses the difference between the deployment of a road anomalies detection and identification system in a “conditioned” and a real world setup, where the system performed worse compared to the “conditioned” setup. It also presents a system performance analysis based on the analysis of the training data sets; on the analysis of the attributes complexity, through the application of PCA techniques; and on the analysis of the attributes in the context of each anomaly type, using acceleration standard deviation attributes to observe how different anomalies classes are distributed in the Cartesian coordinates system. Overall, in this paper, we describe the main insights on road anomalies detection challenges to support the design and deployment of a new iteration of our system towards the deployment of a road anomaly detection service to provide information about roads condition to drivers and government entities.

  13. UNIX-based operating systems robustness evaluation

    Science.gov (United States)

    Chang, Yu-Ming

    1996-01-01

    Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.

  14. Development of a School Leadership Evaluation System

    Science.gov (United States)

    Orlando, Nik

    2014-01-01

    This action research study examined the effectiveness of the process implemented by Partnerships to Uplift Communities (PUC) Schools Charter Management Organization to develop their school leader evaluation system in collaboration with current PUC school leaders. The development of the leadership evaluation system included the collective voices of…

  15. IDEA: A Unifying Theory for Evaluation Systems

    DEFF Research Database (Denmark)

    Bella, Giampaolo; Giustolisi, Rosario

    2017-01-01

    Secure systems for voting, exams, auctions and conference paper management are theorised to address the same problem, that of secure evaluations. In support of such a unifying theory comes a model for Secure Evaluation Systems (SES), which offers innovative common grounds to understand all four...

  16. Solar Thermal System Evaluation in China

    Directory of Open Access Journals (Sweden)

    Xinyu Zhang

    2015-01-01

    Full Text Available More than 581 solar thermal systems (STSs, 98 counties, and 47 renewable application demonstration cites in China need to be inspected by the end of 2015. In this study, the baseline for performance and economic evaluation of STSs are presented based on the site test data and related references. An index used to evaluate STSs was selected, and methods to acquire the parameters used to calculate the related index were set. The requirements for sensors for testing were specified. The evaluation method was applied to three systems and the result shows that the evaluation method is suitable for the evaluation of STSs in China.

  17. Task oriented evaluation system for maintenance robots

    International Nuclear Information System (INIS)

    Asame, Hajime; Endo, Isao; Kotosaka, Shin-ya; Takata, Shozo; Hiraoka, Hiroyuki; Kohda, Takehisa; Matsumoto, Akihiro; Yamagishi, Kiichiro.

    1994-01-01

    The adaptability evaluation of maintenance robots to autonomous plants has been discussed. In this paper, a new concept of autonomous plant with maintenance robots are introduced, and a framework of autonomous maintenance system is proposed. Then, task-oriented evaluation of robot arms is discussed for evaluating their adaptability to maintenance tasks, and a new criterion called operability is proposed for adaptability evaluation. The task-oriented evaluation system is implemented and applied to structural design of robot arms. Using genetic algorithm, an optimal structure adaptable to a pump disassembly task is obtained. (author)

  18. Urogenital system diseases's radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S; Mecozzi, B

    1985-01-01

    Radiological urogenital radiography reliability, can be compromised because of absence of a correct urodynamic diagnosis. It is then required that specialist radiologists know the problems concerning the urogenital system radiographies cannot be made in many cases, because of the scarcity in hospitals of idoneous urodynamic services.

  19. Establishment of nuclear data evaluation system (I)

    International Nuclear Information System (INIS)

    Chang, Jong Hwa; Lee, Chang Kun; Kim, Jeong Do; Kim, Young Sik; Kim, Young Jin; Kim, Hyung Guk; Kil, Chung Sup; Kim, Kang Suk

    1994-08-01

    Nuclear data is fundamental data for development of new type of nuclear, upgrade of nuclear fuel, treatment of radwaste, research on fusion reactor, radioisotope usage, and nuclear medical therapy. Nuclear data is produced with experiments. However rack of experimental data for thousands of nuclides and various reaction types makes it essential to do statistical evaluation and theoretical interpolation. This study is intended to join international cooperation after establishing domestic basis for nuclear data evaluation work. This project is the first year of five year plan to do followings: 1) Establishment of database system to collect experimental data, 2) Setup of computer assistance system for evaluation work, 3) Verification of established system by test evaluation of selected nuclide reaction. The system has a collection of mass data of nuclides, computer codes for test evaluation of total cross section of 0-16 and collection of EXFOR format data for 0-16. This system will be improved continuously on next years. (Author)

  20. Economic framework for information system evaluation

    International Nuclear Information System (INIS)

    King, D.W.; Roderer, N.K.

    1979-01-01

    In the evaluation of complex information systems, it is useful to work within a generalized economic framework. This framework is based on consideration of four evaluation levels, including those associated with the overall system, system functions, products and services, and activities. Measures of cost and output can be defined at each level, with output measures related to volume of activity, performance, effectiveness, and benefit. The description of this framework includes definitions of the terminology used. Examples of the application of the framework to specific information system evaluations are also given. 4 figures

  1. Optimized Evaluation System to Athletic Food Safety

    OpenAIRE

    Shanshan Li

    2015-01-01

    This study presented a new method of optimizing evaluation function in athletic food safety information programming by particle swarm optimization. The process of food information evaluation function is to automatically adjust these parameters in the evaluation function by self-optimizing method accomplished through competition, which is a food information system plays against itself with different evaluation functions. The results show that the particle swarm optimization is successfully app...

  2. In-flight Assessment of Lower Body Negative Pressure as a Countermeasure for Post-flight Orthostatic Intolerance

    Science.gov (United States)

    Charles, J. B.; Stenger, M. B.; Phillips, T. R.; Arzeno, N. M.; Lee, S. M. C.

    2009-01-01

    Introduction. We investigated the efficacy of combining fluid loading with sustained lower body negative pressure (LBNP) to reverse orthostatic intolerance associated with weightlessness during and immediately after Space Shuttle missions. Methods. Shuttle astronauts (n=13) underwent 4 hours of LBNP at -30 mm(Hg) and ingested water and salt ( soak treatment) during flight in two complementary studies. In the first study (n=8), pre-flight heart rate (HR) and blood pressure (BP) responses to an LBNP ramp (5-min stages of -10 mm(Hg) steps to -50 mm(Hg) were compared to responses in-flight one and two days after LBNP soak treatment. In the second study (n=5), the soak was performed 24 hr before landing, and post-flight stand test results of soak subjects were compared with those of an untreated cohort (n=7). In both studies, the soak was scheduled late in the mission and was preceded by LBNP ramp tests at approximately 3-day intervals to document the in-flight loss of orthostatic tolerance. Results. Increased HR and decreased BP responses to LBNP were evident early in-flight. In-flight, one day after LBNP soak, HR and BP responses to LBNP were not different from pre-flight, but the effect was absent the second day after treatment. Post-flight there were no between-group differences in HR and BP responses to standing, but all 5 treatment subjects completed the 5-minute stand test whereas 2 of 7 untreated cohort subjects did not. Discussion. Exaggerated HR and BP responses to LBNP were evident within the first few days of space flight, extending results from Skylab. The combined LBNP and fluid ingestion countermeasure restored in-flight LBNP HR and BP responses to pre-flight levels and provided protection of post-landing orthostatic function. Unfortunately, any benefits of the combined countermeasure were offset by the complexity of its implementation, making it inappropriate for routine application during Shuttle flights.

  3. New evaluation system for antisabotage physical protection

    International Nuclear Information System (INIS)

    Itakura, Shuichiro; Nakagome, Yoshihiro

    2008-01-01

    The discussion on an appropriate level of physical protection has not been elaborated so far because of the confidentiality of its nature, thus resulting in a lack of consensus on this issue. In view of this context, a new system for the evaluation of antisabotage physical protection systems is proposed in this paper, in which we introduce openness to a certain extent in the process of the evaluation. The proposed system is composed of the following three elements; (1) establishment of an evaluation basis threat (EBT), which should be less strong but more likely to occur than the design basis threat (DBT); (2) employment of realistic standard scenarios in the process of evaluation; (3) disclosure of results of evaluation implemented based on the above EBT and standard scenarios. It is expected that this considerably open system will foment peace of mind among citizens as well as create a deterrent effect that would minimize the occurrence of sabotage on nuclear facilities. (author)

  4. How to Evaluate Integrated Library Automation Systems.

    Science.gov (United States)

    Powell, James R.; Slach, June E.

    1985-01-01

    This paper describes methodology used in compiling a list of candidate integrated library automation systems at a corporate technical library. Priorities for automation, identification of candidate systems, the filtering process, information for suppliers, software and hardware considerations, on-site evaluations, and final system selection are…

  5. Evaluation methodologies for security testing biometric systems beyond technological evaluation

    OpenAIRE

    Fernández Saavedra, María Belén

    2013-01-01

    The main objective of this PhD Thesis is the specification of formal evaluation methodologies for testing the security level achieved by biometric systems when these are working under specific contour conditions. This analysis is conducted through the calculation of the basic technical biometric system performance and its possible variations. To that end, the next two relevant contributions have been developed. The first contribution is the definition of two independent biometric performance ...

  6. Evaluation of real time operating system

    International Nuclear Information System (INIS)

    Lee, Cheol Hoon; Cho, Moon Heang; Choi, In Bum; Lee, Jung Won; Kang, Hui Sung

    2006-02-01

    An hard RTOS used in the Nuclear Power Plants must satisfy severe performance requirements even in a worst case scenario. Since operating systems are becoming more complicated, it is not an easy job to evaluate them. So it becomes more important how to evaluate the RTOS's used in the Nuclear Power Plants. The purpose of this work is to survey design examples and performance models of RTOS's used in the nuclear power plants and based on this survey, develop a evaluation technologies

  7. Modeling a support system for the evaluator

    International Nuclear Information System (INIS)

    Lozano Lima, B.; Ilizastegui Perez, F; Barnet Izquierdo, B.

    1998-01-01

    This work gives evaluators a tool they can employ to give more soundness to their review of operational limits and conditions. The system will establish the most adequate method to carry out the evaluation, as well as to evaluate the basis for technical operational specifications. It also includes the attainment of alternative questions to be supplied to the operating entity to support it in decision-making activities

  8. Evaluation system of minerals reserve at Nuclebras

    International Nuclear Information System (INIS)

    Marques, J.P.M.; Guerra, P.A.G.; Vinha, C.A.G. da.

    1980-01-01

    The paper describes the methodology used for the reserve evaluation of minerals, particularly of uranium, as used world wide, and specially at Nuclebras. The paper discusses a series of procedures envolving basic definitions, reserve evaluation methods (Conventional, Statistical and Geoestatistical), data management, use of computer systems, classification of reserves as well as the results achieved [pt

  9. Automatic system for evaluation of ionizing field

    International Nuclear Information System (INIS)

    Pimenta, N.L.; Calil, S.J.

    1992-01-01

    A three-dimensional cartesian manipulator for evaluating the ionizing field and able to position a ionization chamber in any point of the space is developed. The control system is made using a IBM microcomputer. The system aimed the study of isodose curves from ionizing sources, verifying the performance of radiotherapeutic equipment. (C.G.C.)

  10. Expected energy production evaluation for photovoltaic systems

    DEFF Research Database (Denmark)

    Ding, Yi; Østergaard, Jacob; Peng, Wang

    2011-01-01

    A photovoltaic (PV) system consists of many solar panels, which are connected in series, parallel or a combination of both. Energy production for the PV system with various configurations is different. In this paper, a methodology is developed to evaluate and analyze the expected energy production...

  11. Multidimensional evaluation on FR cycle systems

    International Nuclear Information System (INIS)

    Nakai, Ryodai; Fujii, Sumio; Takakuma, Katsuyuki; Katoh, Atsushi; Ono, Kiyoshi; Ohtaki, Akira; Shiotani, Hiroki

    2004-01-01

    This report explains some results of the multidimensional evaluation on various fast reactor cycle system concepts from an interim report of the 2nd phase of ''Feasibility Study on Commercialized FR Cycle System''. This method is designed to give more objective and more quantitative evaluations to clarify commercialized system candidate concepts. Here we brief current evaluation method from the five viewpoints of safety, economy, environment, resource and non-proliferation, with some trial evaluation results for some cycles consist of promising technologies in reactor, core and fuel, reprocessing and fuel manufacture. Moreover, we describe FR cycle deployment scenarios which describe advantages and disadvantages of the cycles from the viewpoints of uranium resource and radioactive waste based on long-term nuclear material mass flow analyses and advantages of the deployment of FR cycle itself from the viewpoints of the comparison with alternative power supplies as well as cost and benefit. (author)

  12. Evaluation of pipeline leak detection systems

    International Nuclear Information System (INIS)

    Glauz, W.D.; Flora, J.D.; Hennon, G.J.

    1993-01-01

    Leaking underground storage tank system presents an environmental concern and a potential health hazard. It is well known that leaks in the piping associated with these systems account for a sizeable fraction of the leaks. EPA has established performance standards for pipeline leak detection systems, and published a document presenting test protocols for evaluating these systems against the standards. This paper discusses a number of facets and important features of evaluating such systems, and presents results from tests of several systems. The importance of temperature differences between the ground and the product in the line is shown both in theory and with test data. The impact of the amount of soil moisture present is addressed, along with the effect of frozen soil. These features are addressed both for line tightness test systems, which must detect leaks of 0.10 gal/h (0.38 L/h) at 150% of normal line pressure, or 0.20 gal/h (0.76 L/h) at normal line pressure, and for automatic line leak detectors that must detect leaks of 3 gal/h (11 L/h) at 10 psi (69 kPa) within an hour of the occurrence of the leak. This paper also addresses some statistical aspects of the evaluation of these systems. Reasons for keeping the evaluation process ''blind'' to the evaluated company are given, along with methods for assuring that the tests are blind. Most importantly, a test procedure is presented for evaluating systems that report a flow rate (not just a pass/fail decision) that is much more efficient than the procedure presented in the EPA protocol, and is just as stringent

  13. Ensuring system security through formal software evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howell, J A; Fuyat, C [Los Alamos National Lab., NM (United States); Elvy, M [Marble Associates, Boston, MA (United States)

    1992-01-01

    With the increasing use of computer systems and networks to process safeguards information in nuclear facilities, the issue of system and data integrity is receiving worldwide attention. Among the many considerations are validation that the software performs as intended and that the information is adequately protected. Such validations are often requested of the Safeguards Systems Group of the Los Alamos National Laboratory. This paper describes our methodology for performing these software evaluations.

  14. System Modeling and Trust Evaluation of Distributed Systems

    OpenAIRE

    Alhadad , Nagham; Serrano-Alvarado , Patricia; Busnel , Yann; Lamarre , Philippe

    2015-01-01

    International audience; Nowadays, digital systems are connected through complex architectures. These systems involve persons, physical and digital resources such that we can consider that a system consists of elements from two worlds, the social world and the digital world, and their relations. Users perform activities like chatting, buying, sharing data, etc. Evaluating and choosing appropriate systems involve aspects like functionality, performance, QoS, ease of use, or price. Recently, tru...

  15. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-01-01

    The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, open-quotes what to protect against whom.close quotes The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given

  16. Concept Evaluation for Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    The yaw system is the subsystem on a wind turbine which ensures that the rotor plane of the turbine always is facing the wind direction. Studies from [1] show that a soft yaw system may be utilized to dampen the loads in the wind turbine structure. The soft yaw system operates much like...... investigation. Loads and yaw demands are based on the IEC 61400-1 standard for wind turbine design, and the loads for this examination are extrapolated from the HAWC2 aeroelastic design code. The concepts are based on a 5 MW off-shore turbine....... a suspension system on a car, leading the loads away from the turbine structure. However, to realize a soft hydraulic yaw system a new design concept must be found. As a part of the development of the new concept a preliminary concept evaluation has been conducted, evaluating seven different hydraulic yaw...

  17. Evaluation of the MADAM waste measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-03-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software.

  18. Evaluation of the MADAM waste measurement system

    International Nuclear Information System (INIS)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-01-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software

  19. Fuzzy comprehensive evaluation of district heating systems

    International Nuclear Information System (INIS)

    Wei Bing; Wang Songling; Li Li

    2010-01-01

    Selecting the optimal type of district heating (DH) system is of great importance because different heating systems have different levels of efficiency, which will impact the system economics, environment and energy use. In this study, seven DH systems were analysed and evaluated by the fuzzy comprehensive evaluation method. The dimensionless number-goodness was introduced into the calculation, the economics, environment and energy technology factors were considered synthetically, and the final goodness values were obtained. The results show that if only one of the economics, environment or energy technology factors are considered, different heating systems have different goodness values. When all three factors were taken into account, the final ranking of goodness values was: combined heating and power>gas-fired boiler>water-source heat pump>coal-fired boiler>ground-source heat pump>solar-energy heat pump>oil-fired boiler. The combined heating and power system is the best choice from all seven systems; the gas-fired boiler system is the best of the three boiler systems for heating purpose; and the water-source heat pump is the best of the three heat pump systems for heating and cooling.

  20. Preparing and evaluating delivery systems for proteins

    DEFF Research Database (Denmark)

    Jorgensen, L; Moeller, E H; van de Weert, M

    2006-01-01

    From a formulation perspective proteins are complex and therefore challenging molecules to develop drug delivery systems for. The success of a formulation depends on the ability of the protein to maintain the native structure and activity during preparation and delivery as well as during shipping...... and long-term storage of the formulation. Therefore, the development and evaluation of successful and promising drug delivery systems is essential. In the present review, some of the particulate drug delivery systems for parenteral delivery of protein are presented and discussed. The challenge...... for incorporation of protein in particulate delivery systems is exemplified by water-in-oil emulsions....

  1. Experimental evaluation of Arabic OCR systems

    Directory of Open Access Journals (Sweden)

    Mansoor Alghamdi

    2017-11-01

    Full Text Available Purpose – The aim of this paper is to experimentally evaluate the effectiveness of the state-of-the-art printed Arabic text recognition systems to determine open areas for future improvements. In addition, this paper proposes a standard protocol with a set of metrics for measuring the effectiveness of Arabic optical character recognition (OCR systems to assist researchers in comparing different Arabic OCR approaches. Design/methodology/approach – This paper describes an experiment to automatically evaluate four well-known Arabic OCR systems using a set of performance metrics. The evaluation experiment is conducted on a publicly available printed Arabic dataset comprising 240 text images with a variety of resolution levels, font types, font styles and font sizes. Findings – The experimental results show that the field of character recognition for printed Arabic still requires further research to reach an efficient text recognition method for Arabic script. Originality/value – To the best of the authors’ knowledge, this is the first work that provides a comprehensive automated evaluation of Arabic OCR systems with respect to the characteristics of Arabic script and, in addition, proposes an evaluation methodology that can be used as a benchmark by researchers and therefore will contribute significantly to the enhancement of the field of Arabic script recognition.

  2. Physical protection system design and evaluation

    International Nuclear Information System (INIS)

    Williams, J.D.

    1997-11-01

    The design of an effective physical protection system (PPS) includes the determination of the PPS objectives, the initial design of a PPS, the evaluation of the design, and probably, the redesign or refinement of the system. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary's capabilities, and range of adversary's tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the PPS, that is, ''what to protect against whom.'' The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control devices, communication devices, procedures, and protective force personnel to meet the objectives of the system. Once a PPS is designed, it must be analyzed and evaluated to ensure it meets the PPS objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. After the system is installed, the threat and system parameters may change with time. If they do, the analysis must be performed periodically to ensure the system objectives are still being met

  3. Evaluation of the nucledyne passive containment system

    International Nuclear Information System (INIS)

    1981-04-01

    This reports contains: (1) an evaluation by Gilbert/Commonwealth (G/C) of the NucleDyne passive Containment System (PCS) as that conceptual design is applied to a Westinghouse, two loop, Pressurized Water Reactor; (2) an evaluation by Westinghouse of two questions about the impact of the PCS on the Nuclear Steam Supply System (NSSS), which were posed by G/C and best answered by an NSSS vendor; and (3) replies to both the Gilbert/Commonwealth report and the Westinghoue report by NucleDyne Engineering Corporation

  4. NHI Component Technical Readiness Evaluation System

    International Nuclear Information System (INIS)

    Sherman, S.; Wilson, Dane F.; Pawel, Steven J.

    2007-01-01

    A decision process for evaluating the technical readiness or maturity of components (i.e., heat exchangers, chemical reactors, valves, etc.) for use by the U.S. DOE Nuclear Hydrogen Initiative is described. This system is used by the DOE NHI to assess individual components in relation to their readiness for pilot-scale and larger-scale deployment and to drive the research and development work needed to attain technical maturity. A description of the evaluation system is provided, and examples are given to illustrate how it is used to assist in component R and D decisions.

  5. Mobile based optical form evaluation system

    Directory of Open Access Journals (Sweden)

    Asım Sinan YÜKSEL

    2016-05-01

    Full Text Available Optical forms that contain multiple-choice answers are widely used both for electing students and evaluating student achievements in education systems in our country and worldwide. Optical forms are evaluated by employing optical mark recognition techniques through optical readers. High cost of these machines, limited access to them, long waiting time for evaluation results make the process hard for educationists working in cities or countries. In this study, a mobile application was developed for the educationists who own mobile phones or tablets for the purpose of evaluating students' answer sheets quickly and independent of location and optical readers. Optical form recognition, reading and evaluation processes are done on the image of student's answer sheet that is taken with the mobile phone or tablet of educationist. The Android based mobile application that we developed has a user-friendly interface, high success rate and is the first of our knowledge application that operates on mobile platforms in this field.

  6. Evaluation of real time operating system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Hoon; Cho, Moon Heang; Choi, In Bum; Lee, Jung Won; Kang, Hui Sung [Chungnam National Univ., Daejeon (Korea, Republic of)

    2006-02-15

    An hard RTOS used in the Nuclear Power Plants must satisfy severe performance requirements even in a worst case scenario. Since operating systems are becoming more complicated, it is not an easy job to evaluate them. So it becomes more important how to evaluate the RTOS's used in the Nuclear Power Plants. The purpose of this work is to survey design examples and performance models of RTOS's used in the nuclear power plants and based on this survey, develop a evaluation technologies.

  7. Evaluation of Explanation Interfaces in Recommender Systems

    Directory of Open Access Journals (Sweden)

    Sergio Cleger-Tamayo

    2017-05-01

    Full Text Available Explaining interfaces become a useful tool in systems that have a lot of content to evaluate by users. The different interfaces represent a help for the undecided users or those who consider systems as boxed black smart. These systems present recommendations to users based on different learning models. In this paper, we present the different objectives of the explanation interfaces and some of the criteria that you can evaluate, as well as a proposal of metrics to obtain results in the experiments. Finally, we showed the main results of a study with real users and their interaction with e-commerce systems. Among the main results, highlight the positive impact in relation to the time of interaction with the applications and acceptance of the recommendations received.

  8. Heuristic Evaluation for Novice Programming Systems

    OpenAIRE

    Kölling, Michael; McKay, Fraser

    2016-01-01

    The past few years has seen a proliferation of novice programming tools. The availability of a large number of systems has made it difficult for many users to choose among them. Even for education researchers, comparing the relative quality of these tools, or judging their respective suitability for a given context, is hard in many instances. For designers of such systems, assessing the respective quality of competing design decisions can be equally difficult.\\ud Heuristic evaluation provides...

  9. Corrosion evaluation of service water system materials

    International Nuclear Information System (INIS)

    Stein, A.A.; Felder, C.M.; Martin, R.L.

    1994-01-01

    The availability and reliability of the service water system is critical for safe operation of a nuclear power plant. Degradation of the system piping and components has forced utilities to re-evaluate the corrosion behavior of current and alternative system materials, to support assessments of the remaining service life of the service water system, selection of replacement materials, implementation of corrosion protection methods and corrosion monitoring programs, and identification of maintenance and operational constraints consistent with the materials used. TU Electric and Stone and Webster developed a service water materials evaluation program for the Comanche Peak Steam Electric Station. Because of the length of exposure and the generic interest in this program by the nuclear power industry, EPRI joined TU to co-sponsor the test program. The program was designed to evaluate the corrosion behavior of current system materials and candidate replacement materials and to determine the operational and design changes which could improve the corrosion performance of the system. Although the test program was designed to be representative of service water system materials and environments targeted to conditions at Comanche Peak, these conditions are typical of and relevant to other fresh water cooled nuclear service water systems. Testing was performed in raw water and water treated with biocide under typical service water operating conditions including continuous flow, intermittent flow, and stagnant conditions. The test program evaluated the 300 Series and 6% molybdenum stainless steels, copper-nickel, titanium, carbon steel, and a formed-in-place nonmetallic pipe lining to determine susceptibility to general, crevice, and microbiologically influenced corrosion and pitting attack. This report presents the results of the test program after 4 years of exposure

  10. Post-Flight Analysis of Selected Fluorocarbon and Other Thin Film Polymer Specimens Flown on MISSE-5

    Science.gov (United States)

    DeGroh, Kim; Finckenor, Miria; Minton, Tim; Brunsvold, Amy; Pippin, Gary

    2007-01-01

    Twenty thin film specimens were flown on M1SSE-5 as a cooperative effort between several organizations. This presentation will report results of initial inspections and post-flight measurements of the optical properties and recession of these materials due to the approx.13 month exposure period on the exterior of the International Space Station. These specimens were located on the "anti-solar" side of the MISSE-5 container and received a low number of Equivalent Sun Hours of solar UV exposure. Profilometry and/or ATF measurements will be conducted to determine thickness changes and atomic oxygen-induced recession rates Six of the specimens were covered with thin Kapton films, 0.1 and 0.3 mil in thickness. The 0.1 mil Kapton was almost completely eroded, suggesting that the atomic oxygen fluence is <8 x 10(exp 19) atoms/sq cm, similar to levels experienced during Space Shuttle materials experiments in the 1980's and 1990's. A comparison of results from MISSE-5 and Space Shuttle experiments will be included for those materials common to both the short and long-term exposures.

  11. Going Soft on Information Systems Evaluation

    Directory of Open Access Journals (Sweden)

    Barry Jackson

    1998-05-01

    Full Text Available The way organisations do business has changed dramatically over the last twenty years and so have their information systems as they attempt to support and promote the business enterprise. The information system has a key role to play in the success or possible failure of the business yet, despite its importance, there is little evidence that the components of the information systems evaluation process have kept pace with its changing role as they tend to rely on techniques based on narrow tangible/objective methods rather than on more holistic approaches which, in addition to the more traditional methods, include social, political and cultural perspectives more in keeping with the complex interactions associated with modern organisations. The paper charts the recent progress of organisational change, the increasing role of information systems within the organisation, and the information systems evaluation processes. It concludes with a proposal as to how the evaluation process could be widened to include the views and interests of a larger range of stakeholders by drawing upon elements of the soft systems methodology.

  12. CTBT integrated verification system evaluation model supplement

    Energy Technology Data Exchange (ETDEWEB)

    EDENBURN,MICHAEL W.; BUNTING,MARCUS; PAYNE JR.,ARTHUR C.; TROST,LAWRENCE C.

    2000-03-02

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0.

  13. CTBT integrated verification system evaluation model supplement

    International Nuclear Information System (INIS)

    EDENBURN, MICHAEL W.; BUNTING, MARCUS; PAYNE, ARTHUR C. JR.; TROST, LAWRENCE C.

    2000-01-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0

  14. Overview of Pre-Flight Physical Training, In-Flight Exercise Countermeasures and the Post-Flight Reconditioning Program for International Space Station Astronauts

    Science.gov (United States)

    Kerstman, Eric

    2011-01-01

    International Space Station (ISS) astronauts receive supervised physical training pre-flight, utilize exercise countermeasures in-flight, and participate in a structured reconditioning program post-flight. Despite recent advances in exercise hardware and prescribed exercise countermeasures, ISS crewmembers are still found to have variable levels of deconditioning post-flight. This presentation provides an overview of the astronaut medical certification requirements, pre-flight physical training, in-flight exercise countermeasures, and the post-flight reconditioning program. Astronauts must meet medical certification requirements on selection, annually, and prior to ISS missions. In addition, extensive physical fitness testing and standardized medical assessments are performed on long duration crewmembers pre-flight. Limited physical fitness assessments and medical examinations are performed in-flight to develop exercise countermeasure prescriptions, ensure that the crewmembers are physically capable of performing mission tasks, and monitor astronaut health. Upon mission completion, long duration astronauts must re-adapt to the 1 G environment, and be certified as fit to return to space flight training and active duty. A structured, supervised postflight reconditioning program has been developed to prevent injuries, facilitate re-adaptation to the 1 G environment, and subsequently return astronauts to training and space flight. The NASA reconditioning program is implemented by the Astronaut Strength, Conditioning, and Rehabilitation (ASCR) team and supervised by NASA flight surgeons. This program has evolved over the past 10 years of the International Space Station (ISS) program and has been successful in ensuring that long duration astronauts safely re-adapt to the 1 g environment and return to active duty. Lessons learned from this approach to managing deconditioning can be applied to terrestrial medicine and future exploration space flight missions.

  15. Evaluating Evaluation Systems: Policy Levers and Strategies for Studying Implementation of Educator Evaluation. Policy Snapshot

    Science.gov (United States)

    Matlach, Lauren

    2015-01-01

    Evaluation studies can provide feedback on implementation, support continuous improvement, and increase understanding of evaluation systems' impact on teaching and learning. Despite the importance of educator evaluation studies, states often need support to prioritize and fund them. Successful studies require expertise, time, and a shared…

  16. Reliability evaluation of a natural circulation system

    International Nuclear Information System (INIS)

    Jafari, Jalil; D'Auria, Francesco; Kazeminejad, Hossein; Davilu, Hadi

    2003-01-01

    This paper discusses a reliability study performed with reference to a passive thermohydraulic natural circulation (NC) system, named TTL-1. A methodology based on probabilistic techniques has been applied with the main purpose to optimize the system design. The obtained results have been adopted to estimate the thermal-hydraulic reliability (TH-R) of the same system. A total of 29 relevant parameters (including nominal values and plausible ranges of variations) affecting the design and the NC performance of the TTL-1 loop are identified and a probability of occurrence is assigned for each value based on expert judgment. Following procedures established for the uncertainty evaluation of thermal-hydraulic system codes results, 137 system configurations have been selected and each configuration has been analyzed via the Relap5 best-estimate code. The reference system configuration and the failure criteria derived from the 'mission' of the passive system are adopted for the evaluation of the system TH-R. Four different definitions of a less-than-unity 'reliability-values' (where unity represents the maximum achievable reliability) are proposed for the performance of the selected passive system. This is normally considered fully reliable, i.e. reliability-value equal one, in typical Probabilistic Safety Assessment (PSA) applications in nuclear reactor safety. The two 'point' TH-R values for the considered NC system were found equal to 0.70 and 0.85, i.e. values comparable with the reliability of a pump installed in an 'equivalent' forced circulation (active) system having the same 'mission'. The design optimization study was completed by a regression analysis addressing the output of the 137 calculations: heat losses, undetected leakage, loop length, riser diameter, and equivalent diameter of the test section have been found as the most important parameters bringing to the optimal system design and affecting the TH-R. As added values for this work, the comparison has

  17. Cedar Avenue driver assist system evaluation report.

    Science.gov (United States)

    2011-12-01

    This paper summarizes an evaluation of the Driver Assist System (DAS) used by the Minnesota Valley Transit Authority (MTVA) for bus shoulder operations. The DAS is a GPS-based technology suite that provides lane-position feedback to the driver via a ...

  18. A Social Systems Approach to Evaluation Research.

    Science.gov (United States)

    Olien, C. N.; And Others

    An information-control systems model for evaluation of adult education programs is offered and illustrated. The model is based upon identifying principal subsystems, such as source, channel and audience, which are involved in initiation, production, delivery and reception of educational messages. These subsystems are seen as separate but…

  19. Pervious Pavement System Evaluation-Paper

    Science.gov (United States)

    The use of a pervious pavement can be effective as a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete paver systems as a type of porous pavement. Although the pavers are impermeable, the spaces between the pave...

  20. Virginia power's human performance evaluation system (HPES)

    International Nuclear Information System (INIS)

    Patterson, W.E.

    1991-01-01

    This paper reports on the Human Performance Evaluation System (HPES) which was initially developed by the Institute of Nuclear Power Operations (INPO) using the Aviation Safety Reporting System (ASRS) as a guide. After a pilot program involving three utilities ended in 1983, the present day program was instituted. A methodology was developed, for specific application to nuclear power plant employees, to aid trained coordinators/evaluators in determining those factors that exert a negative influence on human behavior in the nuclear power plant environment. HPES is for anyone and everyone on site, from contractors to plant staff to plant management. No one is excluded from participation. Virginia Power's HPES program goal is to identify and correct the root causes of human performance problems. Evaluations are performed on reported real or perceived conditions that may have an adverse influence on members of the nuclear team. A report is provided to management identifying root cause and contributing factors along with recommended corrective actions

  1. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  2. CORBA Evaluations for the BABAR Online System

    International Nuclear Information System (INIS)

    Glanzman, Thomas

    1998-01-01

    The Common Object Request Broker Architecture (CORBA) is a software system to deal with distributed object computing. The release of CORBA version 2, and real implementations from numerous vendors (both freeware and payware) have made its use very attractive for interprocess and interprocessor communication within an object-oriented software system. A number of object request brokers (ORBs) were evaluated for possible use within the BABAR Online system. Given an expectation for a reasonable level of performance within the Online system, it was essential to characterize the behavior and test the response of these products prior to their adoption. This paper summarizes the results of a systematic performance study of six ORB products. The products tested include: Visibroker, Orbix, DAIS, Omnibroker, OmniORB2, and TAO. Performance results of ORB products, including a test of TCP/IP sockets, are compared. These tests resulted in the adoption of the TAO ORB for use within the BABAR Online system

  3. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  4. Composite system reliability evaluation by stochastic calculation of system operation

    Energy Technology Data Exchange (ETDEWEB)

    Haubrick, H -J; Hinz, H -J; Landeck, E [Dept. of Power Systems and Power Economics (Germany)

    1994-12-31

    This report describes a new developed probabilistic approach for steady-state composite system reliability evaluation and its exemplary application to a bulk power test system. The new computer program called PHOENIX takes into consideration transmission limitations, outages of lines and power stations and, as a central element, a highly sophisticated model to the dispatcher performing remedial actions after disturbances. The kernel of the new method is a procedure for optimal power flow calculation that has been specially adapted for the use in reliability evaluations under the above mentioned conditions. (author) 11 refs., 8 figs., 1 tab.

  5. Evaluation of a multiport groundwater monitoring system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Hall, S.H.; Olsen, K.B.; Spane, F.A. Jr.

    1991-03-01

    In 1988 and 1989, Pacific Northwest Laboratory installed a multiport groundwater monitoring system in two wells on the Hanford Site: one near the 216-B-3 Pond in the center of the Hanford Site and one just north of the 300 Area near the Columbia River. The system was installed to provide the US Department of Energy with needed three-dimensional data on the vertical distribution of contaminants and hydraulic heads on the Hanford Site. This study evaluates the ability of the multiport system to obtain hydrogeologic data at multiple points vertically in a single borehole, and addresses the representativeness of the data. Data collected from the two wells indicate that the multiport system is well suited for groundwater monitoring networks requiring three-dimensional characterization of the hydrogeologic system. A network of these systems could provide valuable information on the hydrogeologic environment. However, the advantages of the multiport system diminish when the system is applied to long-term monitoring networks (30+ years) and to deeper wells (<300 ft). For shallow wells, the multiport system provides data in a cost-effective manner that would not be reasonably obtainable with the conventional methods currently in use at the Hanford Site. 17 refs., 28 figs., 6 tabs

  6. Multi-purpose canister system evaluation: A systems engineering approach

    International Nuclear Information System (INIS)

    1994-09-01

    This report summarizes Department of Energy (DOE) efforts to investigate various container systems for handling, transporting, storing, and disposing of spent nuclear fuel (SNF) assemblies in the Civilian Radioactive Waste Management System (CRWMS). The primary goal of DOE's investigations was to select a container technology that could handle the vast majority of commercial SNF at a reasonable cost, while ensuring the safety of the public and protecting the environment. Several alternative cask and canister concepts were evaluated for SNF assembly packaging to determine the most suitable concept. Of these alternatives, the multi-purpose canister (MPC) system was determined to be the most suitable. Based on the results of these evaluations, the decision was made to proceed with design and certification of the MPC system. A decision to fabricate and deploy MPCs will be made after further studies and preparation of an environmental impact statement

  7. SatisFactory Final System Evaluation Report

    OpenAIRE

    Sunlight SA

    2018-01-01

    The present document is a deliverable of the SatisFactory project, funded by the European Commission’s Directorate-General for Research and Innovation (DG RTD), under its Horizon 2020 Research and innovation programme (H2020). The main objective of this deliverable is to report on the SatisFactory Final System Evaluation, with regards to the industrial pilots at COMAU and SUNLIGHT. The evaluation of SatisFactory platform is based on the implementation of the business scenarios where each tool...

  8. Enforcement of evaluation by achievement analysis system

    International Nuclear Information System (INIS)

    Konishi, Yasutoshi; Sonoyama, Minoru; Suzuki, Atsushi

    2004-02-01

    Japan Nuclear Cycle Development Institute (JNC) has developed FBR achievement analysis system by the last fiscal year and has enforced the investigation of its functional expansion. That system is based on the AHP (Analytic Hierarchy Process) to do comparative evaluation multilaterally between proposed concepts of FBR cycle or between FBR cycle and other power source systems. This fiscal year, we enforced achievement analysis for 22 cases of proposed concepts of FBR cycle and between FBR cycle and other power source systems (LWR, thermal power generation, hydraulic power generation, etc.). The evaluation items related with technical feasibility and social acceptability were included in addition to those of economy, resource utilization effectiveness, environmental burden reduction, nuclear proliferation resistance and safety. Also, we investigated social changes that could happen in our country in the future, and we drew 4 future scenarios combining likely changes, then we investigated classifications of weight that seem to be adequate under each scenario with its calculation logic. In establishing points of view or structure of evaluation, and in the process of drawing scenarios, we collected comments from experts in OR (Operations Research) field and energy field. (author)

  9. Evaluation of a prototype infrasound system

    International Nuclear Information System (INIS)

    Whitaker, R.; Sandoval, T.; Breding, D.; Kromer, D.

    1997-01-01

    Under Department of Energy sponsorship, Sandia National Laboratories and Los Alamos National Laboratory cooperated to develop a prototype infrasonic array, with associated documentation, that could be used as part of the International Monitoring System. The United States Government or foreign countries could procure commercially available systems based on this prototype to fulfill their Comprehensive Test Ban Treaty (CTBT) obligations. The prototype is a four-element array in a triangular layout as recommended in CD/NTB/WP.224 with an element at each corner and one in the center. The prototype test configuration utilize an array spacing of 1 km. The prototype infrasound system has the following objectives: (1) Provide a prototype that reliably acquires and transmits near real-time infrasonic data to facilitate the rapid location and identification of atmospheric events. (2) Provide documentation that could be used by the United States and foreign countries to procure infrasound systems commercially to fulfill their CTBT responsibilities. Infrasonic monitoring is an effective, low cost technology for detecting atmospheric explosions. The low frequency components of explosion signals propagate to long ranges (few thousand kilometers) where they can be detected with an array of sensors. Los Alamos National Laboratory's expertise in infrasound systems and phenomenology when combined with Sandia's expertise in providing verification quality system for treaty monitoring make an excellent team to provide the prototype infrasound sensor system. By September 1997, the prototype infrasound system will have been procured, integrated, evaluated and documented. Final documentation will include a system requirements document, an evaluation report and a hardware design document. The hardware design document will describe the various hardware components used in the infrasound prototype and their interrelationships

  10. CTBT Integrated Verification System Evaluation Model

    Energy Technology Data Exchange (ETDEWEB)

    Edenburn, M.W.; Bunting, M.L.; Payne, A.C. Jr.

    1997-10-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia`s Monitoring Systems and Technology Center and has been funded by the US Department of Energy`s Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, top-level, modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM`s unique features is that it integrates results from the various CTBT sensor technologies (seismic, infrasound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection) and location accuracy of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system`s performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. This report describes version 1.2 of IVSEM.

  11. Operational plans for life science payloads - From experiment selection through postflight reporting

    Science.gov (United States)

    Mccollum, G. W.; Nelson, W. G.; Wells, G. W.

    1976-01-01

    Key features of operational plans developed in a study of the Space Shuttle era life science payloads program are presented. The data describes the overall acquisition, staging, and integration of payload elements, as well as program implementation methods and mission support requirements. Five configurations were selected as representative payloads: (a) carry-on laboratories - medical emphasis experiments, (b) mini-laboratories - medical/biology experiments, (c) seven-day dedicated laboratories - medical/biology experiments, (d) 30-day dedicated laboratories - Regenerative Life Support Evaluation (RLSE) with selected life science experiments, and (e) Biomedical Experiments Scientific Satellite (BESS) - extended duration primate (Type I) and small vertebrate (Type II) missions. The recommended operational methods described in the paper are compared to the fundamental data which has been developed in the life science Spacelab Mission Simulation (SMS) test series. Areas assessed include crew training, experiment development and integration, testing, data-dissemination, organization interfaces, and principal investigator working relationships.

  12. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.; Gurbuz, E.

    1993-03-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSCsuperconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  13. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.G.; Gurbuz, E.

    1994-01-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSC superconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  14. Learning towards system innovation: Evaluating a systemic instrument

    NARCIS (Netherlands)

    Mierlo, B. van; Leeuwis, C.; Smits, R.; Klein Woolthuis, R.J.A.

    2010-01-01

    In this paper we develop an analytical framework for studying learning processes in the context of efforts to bring about system innovation by building new networks of actors who are willing to work on a change towards sustainable development. We then use it to evaluate two specific intervention

  15. A Proposed RTN Officer Performance Evaluation System

    Science.gov (United States)

    1989-12-01

    Taa& No. WokI Unlit Acca ~def 11¶. TITLE (biclde Securiy ClassifiCation) A PROPOSED ROYAL THAI NAVY OFIICER PERFORM NCE EVALUATION SYSTEM 12. PERSONAL...all aspects of performance into account , the commanding officer uses his opinion to decide who is "the best." There are no standard guidelines for...ftequently used in orgunsadozn as a bais for adminiardstive decisions such as employee promotion., tuufer, and allocation of financial reward; employee

  16. Comprehensive evaluation system of intelligent urban growth

    Science.gov (United States)

    Li, Lian-Yan; Ren, Xiao-Bin

    2017-06-01

    With the rapid urbanization of the world, urban planning has become increasingly important and necessary to ensure people have access to equitable and sustainable homes, resources and jobs.This article is to talk about building an intelligent city evaluation system.First,using System Analysis Model(SAM) which concludes literature data analysis and stepwise regression analysis to describe intelligent growth scientifically and obtain the evaluation index. Then,using the improved entropy method to obtain the weight of the evaluation index.Afterwards, establishing a complete Smart Growth Comprehensive Evaluation Model(SGCEM).Finally,testing the correctness of the model.Choosing Otago(New Zealand )and Yumen(China) as research object by data mining and SGCEM model,then we get Yumen and Otago’s rational degree’s values are 0.3485 and 0.5376 respectively. It’s believed that the Otago’s smart level is higher,and it is found that the estimated value of rationality is consistent with the reality.

  17. TurboTech Technical Evaluation Automated System

    Science.gov (United States)

    Tiffany, Dorothy J.

    2009-01-01

    TurboTech software is a Web-based process that simplifies and semiautomates technical evaluation of NASA proposals for Contracting Officer's Technical Representatives (COTRs). At the time of this reporting, there have been no set standards or systems for training new COTRs in technical evaluations. This new process provides boilerplate text in response to interview style questions. This text is collected into a Microsoft Word document that can then be further edited to conform to specific cases. By providing technical language and a structured format, TurboTech allows the COTRs to concentrate more on the actual evaluation, and less on deciding what language would be most appropriate. Since the actual word choice is one of the more time-consuming parts of a COTRs job, this process should allow for an increase in quantity of proposals evaluated. TurboTech is applicable to composing technical evaluations of contractor proposals, task and delivery orders, change order modifications, requests for proposals, new work modifications, task assignments, as well as any changes to existing contracts.

  18. Solar energy system economic evaluation: IBM System 4, Clinton, Mississippi

    Science.gov (United States)

    1980-01-01

    An economic analysis of the solar energy system was developed for five sites, typical of a wide range of environmental and economic conditions in the continental United States. The analysis was based on the technical and economic models in the F-chart design procedure, with inputs based on the characteristic of the installed system and local conditions. The results are of the economic parameters of present worth of system cost over a 20 year time span: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  19. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  20. Ultrasonic nondestructive evaluation systems industrial application issues

    CERN Document Server

    Callegari, Sergio; Montisci, Augusto; Ricci, Marco; Versaci, Mario

    2015-01-01

    This book covers the practical implementation of ultrasonic NDT techniques in an industrial environment, discussing several issues that may emerge and proposing strategies for addressing them successfully.  It aims to bridge advanced academic research results and their application to industrial procedures. The topics covered in the text range from the basic operation of an ultrasonic NDT system to the simulation of the measurement operations; from the choice and generation of the signals energizing the system to the different ways of exploiting the probes and their output signals; and from quality assessment evaluation to the use of soft computing techniques for classification. Throughout the text, an effort is made to embrace a system view where the physical and technological aspects of sensing are addressed together with higher abstraction levels, such as signal and information processing. Consequently, the book aims at guiding the reader through the various tasks requested for developing a complete ultras...

  1. Evaluation of PEGIT duct connection system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Brenner, Douglas E.; Sherman, Max H.; Dickerhoff, Darryl J.

    2003-08-01

    Most air duct system components are assembled in the field and are mechanically fastened by sheet metal screws (for sheet metal-to-sheet metal) or by drawbands (for flex duct-to-sheet metal). Air sealing is separate from this mechanical fastening and is usually achieved using tape or mastic products after mechanical fastening. Field observations have shown that mechanical fastening rarely meets code or manufacturers requirements and that sealing procedures are similarly inconsistent. To address these problems, Proctor Engineering Group (PEG) is developing a system of joining ducts (called PEGIT) that combines the mechanical fastening and sealing into a single self-contained procedure. The PEGIT system uses a shaped flexible seal between specially designed sheet metal duct fittings to both seal and fasten duct sections together. Figure 1 shows the inner duct fitting complete with rubber seal. This seal provides the air seal for the completed fitting and is shaped to allow the inner and outer fittings to slide together, and then to lock the fittings in place. The illustration in Figure 2 shows the approximate cross section of the rubber seal that shows how the seal has a lip that is angled backwards. This angled lip allows the joint to be pushed together by folding flat but then its long axis makes it stiff in the pulling apart direction. This study was undertaken to assist PEG in some of the design aspects of this system and to test the performance of the PEGIT system. This study was carried out in three phases. The initial phase evaluated the performance of a preliminary seal design for the PEGIT system. After the first phase, the seal was redesigned and this new seal was evaluated in the second phase of testing. The third phase performed more detailed testing of the second seal design to optimize the production tolerances of the sheet metal fittings. This report summarizes our findings from the first two phases and provides details about the third phase of testing.

  2. Evaluation of Nuclear Hydrogen Production System

    International Nuclear Information System (INIS)

    Park, Won Seok; Park, C. K.; Park, J. K. and others

    2006-04-01

    The major objective of this work is tow-fold: one is to develop a methodology to determine the best VHTR types for the nuclear hydrogen demonstration project and the other is to evaluate the various hydrogen production methods in terms of the technical feasibility and the effectiveness for the optimization of the nuclear hydrogen system. Both top-tier requirements and design requirements have been defined for the nuclear hydrogen system. For the determination of the VHTR type, a comparative study on the reference reactors, PBR and PBR, was conducted. Based on the analytic hierarchy process (AHP) method, a systematic methodology has been developed to compare the two VHTR types. Another scheme to determine the minimum reactor power was developed as well. Regarding the hydrogen production methods, comparison indices were defined and they were applied to the IS (Iodine-Sulfur) scheme, Westinghouse process, and the, high-temperature electrolysis method. For the HTE, IS, and MMI cycle, the thermal efficiency of hydrogen production were systematically evaluated. For the IS cycle, an overall process was identified and the functionality of some key components was identified. The economy of the nuclear hydrogen was evaluated, relative to various primary energy including natural gas coal, grid-electricity, and renewable. For the international collaborations, two joint research centers were established: NH-JRC between Korea and China and NH-JDC between Korea and US. Currently, several joint researches are underway through the research centers

  3. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  4. Evaluation of transmitted images by teleradiology system

    International Nuclear Information System (INIS)

    Hoshikawa, Yoshikazu

    1993-01-01

    Teleradiology system is a combination of digital data networks and computer systems, which is the electric transmission of radiographs and/or radiologic images from local to center radiological system. The author evaluated reproducibility of transmitted images using Photophone (Image Data Corporation) as teleradiology system. Proven cases of abdominal free air (38 plain films, 15 CT), pneumothorax (24 plain films, 20 CT) and small bowel obstruction (30 plain films, 8 CT) were transmitted. Findings could be identified on non-magnified plain films in 75.6%, 83.3% and 96.7% respectively and on magnified CT in 100%, 100% and 100%. Transmitted images of 57 cases of abdominal trauma were read for positive findings and diagnosis by three radiologists. Average positive ratio was 47.3% on plain films and 70.9% on CT. Diagnosis was correct in 66.7% on CT. Specificity and sensitivity were 81.9% and 61.6% respectively on plain film and 88.6% and 93.9% on CT. The accuracy of transmitted images appears to be unsatisfactory on this study. It is suggested that the system is useful for consultation of already identified findings on the original images. (author)

  5. Evaluation of transmitted images by teleradiology system

    Energy Technology Data Exchange (ETDEWEB)

    Hoshikawa, Yoshikazu (St. Marianna Univ., Kawasaki (Japan). School of Medicine)

    1993-12-01

    Teleradiology system is a combination of digital data networks and computer systems, which is the electric transmission of radiographs and/or radiologic images from local to center radiological system. The author evaluated reproducibility of transmitted images using Photophone (Image Data Corporation) as teleradiology system. Proven cases of abdominal free air (38 plain films, 15 CT), pneumothorax (24 plain films, 20 CT) and small bowel obstruction (30 plain films, 8 CT) were transmitted. Findings could be identified on non-magnified plain films in 75.6%, 83.3% and 96.7% respectively and on magnified CT in 100%, 100% and 100%. Transmitted images of 57 cases of abdominal trauma were read for positive findings and diagnosis by three radiologists. Average positive ratio was 47.3% on plain films and 70.9% on CT. Diagnosis was correct in 66.7% on CT. Specificity and sensitivity were 81.9% and 61.6% respectively on plain film and 88.6% and 93.9% on CT. The accuracy of transmitted images appears to be unsatisfactory on this study. It is suggested that the system is useful for consultation of already identified findings on the original images. (author).

  6. Prototype of evaluation guidance system in Integrated Nuclear Data Evaluation System

    International Nuclear Information System (INIS)

    Fukahori, T.; Nakagawa, T.

    1992-01-01

    Integrated Nuclear Data Evaluation System (INDES) is being developed to keep experiences of nuclear data evaluation for JENDL-3 and to support new evaluations. One of the INDES functions is to set up input data of theoretical calculation codes automatically. In order to use INDES effectively, a prototype of nuclear data evaluation guidance system (E.T.; Evaluation Tutor) was made to help users in selecting a set of suitable theoretical calculation codes by applying knowledge engineering technology. E.T. consists of an inference engine, frames, a rule-base, two example-bases and calculating modules of certainty factors. The inference engine and the calculating modules are written in FORTRAN77. (author)

  7. Evaluation of an automatic uranium titration system

    International Nuclear Information System (INIS)

    Lewis, K.

    1980-01-01

    The titration system utilizes the constant current coulometric titration of Goldbeck and Lerner. U(VI) is reduced to U(IV) by Fe(II). V(V) is generated to titrate the U(IV), and the titration is followed potentiometrically. The evaluation shows that the recovery of uranium is 100% at the 40-mg level. The accuracy is generally +-0.10% or better. The smallest sample weight at which reliable results were obtained was 40 mg of uranium. Time for one analysis is 15 minutes. Advantages and disadvantages of the automated titrator are listed

  8. Evaluation of Security Solutions for Android Systems

    OpenAIRE

    Shabtai, Asaf; Mimran, Dudu; Elovici, Yuval

    2015-01-01

    With the increasing usage of smartphones a plethora of security solutions are being designed and developed. Many of the security solutions fail to cope with advanced attacks and are not aways properly designed for smartphone platforms. Therefore, there is a need for a methodology to evaluate their effectiveness. Since the Android operating system has the highest market share today, we decided to focus on it in this study in which we review some of the state-of-the-art security solutions for A...

  9. Fusion-fission energy systems evaluation

    International Nuclear Information System (INIS)

    Teofilo, V.L.; Aase, D.T.; Bickford, W.E.

    1980-01-01

    This report serves as the basis for comparing the fusion-fission (hybrid) energy system concept with other advanced technology fissile fuel breeding concepts evaluated in the Nonproliferation Alternative Systems Assessment Program (NASAP). As such, much of the information and data provided herein is in a form that meets the NASAP data requirements. Since the hybrid concept has not been studied as extensively as many of the other fission concepts being examined in NASAP, the provided data and information are sparse relative to these more developed concepts. Nevertheless, this report is intended to provide a perspective on hybrids and to summarize the findings of the rather limited analyses made to date on this concept

  10. Fusion-fission energy systems evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Teofilo, V.L.; Aase, D.T.; Bickford, W.E.

    1980-01-01

    This report serves as the basis for comparing the fusion-fission (hybrid) energy system concept with other advanced technology fissile fuel breeding concepts evaluated in the Nonproliferation Alternative Systems Assessment Program (NASAP). As such, much of the information and data provided herein is in a form that meets the NASAP data requirements. Since the hybrid concept has not been studied as extensively as many of the other fission concepts being examined in NASAP, the provided data and information are sparse relative to these more developed concepts. Nevertheless, this report is intended to provide a perspective on hybrids and to summarize the findings of the rather limited analyses made to date on this concept.

  11. An evaluation of classification systems for stillbirth

    Directory of Open Access Journals (Sweden)

    Pattinson Robert

    2009-06-01

    Full Text Available Abstract Background Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. Methods We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score Results InfoKeep scores were significantly different across the classifications (p ≤ 0.01 due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD score of 3.40 (0.73 followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00, 2.36 (1.21, 1.92 (1.24 respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p ≤ 0.01, all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. Conclusion The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the best agreement and a low proportion of unexplained stillbirths. The virtues of these systems need to be considered in the development of an

  12. An evaluation of classification systems for stillbirth.

    Science.gov (United States)

    Flenady, Vicki; Frøen, J Frederik; Pinar, Halit; Torabi, Rozbeh; Saastad, Eli; Guyon, Grace; Russell, Laurie; Charles, Adrian; Harrison, Catherine; Chauke, Lawrence; Pattinson, Robert; Koshy, Rachel; Bahrin, Safiah; Gardener, Glenn; Day, Katie; Petersson, Karin; Gordon, Adrienne; Gilshenan, Kristen

    2009-06-19

    Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score <2 considered unsatisfactory); inter-observer agreement and the proportion of unexplained stillbirths. A randomly selected subset of 100 stillbirths was used to assess inter-observer agreement. InfoKeep scores were significantly different across the classifications (p < or = 0.01) due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD) score of 3.40 (0.73) followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00), 2.36 (1.21), 1.92 (1.24) respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p < or = 0.01), all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the

  13. Information System Architectures: Representation, Planning and Evaluation

    Directory of Open Access Journals (Sweden)

    André Vasconcelos

    2003-12-01

    Full Text Available In recent years organizations have been faced with increasingly demanding business environments - pushed by factors like market globalization, need for product and service innovation and product life cycle reduction - and with new information technologies changes and opportunities- such as the Component-off-the-shelf paradigm, the telecommunications improvement or the Enterprise Systems off-the-shelf modules availability - all of which impose a continuous redraw and reorganization of business strategies and processes. Nowadays, Information Technology makes possible high-speed, efficient and low cost access to the enterprise information, providing the means for business processes automation and improvement. In spite of these important technological progresses, information systems that support business, do not usually answer efficiently enough to the continuous demands that organizations are faced with, causing non-alignment between business and information technologies (IT and therefore reducing organization competitive abilities. This article discusses the vital role that the definition of an Information System Architecture (ISA has in the development of Enterprise Information Systems that are capable of staying fully aligned with organization strategy and business needs. In this article the authors propose a restricted collection of founding and basis operations, which will provide the conceptual paradigm and tools for proper ISA handling. These tools are then used in order to represent, plan and evaluate an ISA of a Financial Group.

  14. Distributed Impact Detector System (DIDS) Health Monitoring System Evaluation

    Science.gov (United States)

    Prosser, William H.; Madaras, Eric I.

    2010-01-01

    Damage due to impacts from micrometeoroids and orbital debris is one of the most significant on-orbit hazards for spacecraft. Impacts to thermal protection systems must be detected and the damage evaluated to determine if repairs are needed to allow safe re-entry. To address this issue for the International Space Station Program, Langley Research Center and Johnson Space Center technologists have been working to develop and implement advanced methods for detecting impacts and resultant leaks. LaRC funded a Small Business Innovative Research contract to Invocon, Inc. to develop special wireless sensor systems that are compact, light weight, and have long battery lifetimes to enable applications to long duration space structures. These sensor systems are known as distributed impact detection systems (DIDS). In an assessment, the NASA Engineering and Safety Center procured two prototype DIDS sensor units to evaluate their capabilities in laboratory testing and field testing in an ISS Node 1 structural test article. This document contains the findings of the assessment.

  15. Real-time ultrasonic weld evaluation system

    Science.gov (United States)

    Katragadda, Gopichand; Nair, Satish; Liu, Harry; Brown, Lawrence M.

    1996-11-01

    Ultrasonic testing techniques are currently used as an alternative to radiography for detecting, classifying,and sizing weld defects, and for evaluating weld quality. Typically, ultrasonic weld inspections are performed manually, which require significant operator expertise and time. Thus, in recent years, the emphasis is to develop automated methods to aid or replace operators in critical weld inspections where inspection time, reliability, and operator safety are major issues. During this period, significant advances wee made in the areas of weld defect classification and sizing. Very few of these methods, however have found their way into the market, largely due to the lack of an integrated approach enabling real-time implementation. Also, not much research effort was directed in improving weld acceptance criteria. This paper presents an integrated system utilizing state-of-the-art techniques for a complete automation of the weld inspection procedure. The modules discussed include transducer tracking, classification, sizing, and weld acceptance criteria. Transducer tracking was studied by experimentally evaluating sonic and optical position tracking techniques. Details for this evaluation are presented. Classification is obtained using a multi-layer perceptron. Results from different feature extraction schemes, including a new method based on a combination of time and frequency-domain signal representations are given. Algorithms developed to automate defect registration and sizing are discussed. A fuzzy-logic acceptance criteria for weld acceptance is presented describing how this scheme provides improved robustness compared to the traditional flow-diagram standards.

  16. The effectiveness of ground level post-flight 100 percent oxygen breathing as therapy for pain-only altitude Decompression Sickness (DCS)

    Science.gov (United States)

    Demboski, John T.; Pilmanis, Andrew A.

    1994-01-01

    In both the aviation and space environments, decompression sickness (DCS) is an operational limitation. Hyperbaric recompression is the most efficacious treatment for altitude DCS. However, the inherent recompression of descent to ground level while breathing oxygen is in itself therapy for altitude DCS. If pain-only DCS occurs during a hypobaric exposure, and the symptoms resolver during descent, ground level post-flight breathing of 100% O2 for 2 hours (GLO2) is considered sufficient treatment by USAF Regulation 161-21. The effectiveness of the GLO2 treatment protocol is defined.

  17. An hierarchical approach to performance evaluation of expert systems

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Kavi, Srinu

    1985-01-01

    The number and size of expert systems is growing rapidly. Formal evaluation of these systems - which is not performed for many systems - increases the acceptability by the user community and hence their success. Hierarchical evaluation that had been conducted for computer systems is applied for expert system performance evaluation. Expert systems are also evaluated by treating them as software systems (or programs). This paper reports many of the basic concepts and ideas in the Performance Evaluation of Expert Systems Study being conducted at the University of Southwestern Louisiana.

  18. Systems considerations in seismic margin evaluations

    International Nuclear Information System (INIS)

    Buttermer, D.R.

    1987-01-01

    Increasing knowledge in the geoscience field has led to the understanding that, although highly unlikely, it is possible for a nuclear power plant to be subjected to earthquake ground motion greater than that for which the plant was designed. While it is recognized that there are conservatisms inherent in current design practices, interest has developed in evaluating the seismic risk of operating plants. Several plant-specific seismic probabilistic risk assessments (SPRA) have been completed to address questions related to the seismic risk of a plant. The results from such SPRAs are quite informative, but such studies may entail a considerable amount of expensive analysis of large portions of the plant. As an alternative to an SPRA, it may be more practical to select an earthquake level above the design basis for which plant survivability is to be demonstrated. The principal question to be addressed in a seismic margin evaluation is: At what ground motion levels does one have a high confidence that the probability of seismically induced core damage is sufficiently low? In a seismic margin evaluation, an earthquake level is selected (based on site-specific geoscience considerations) for which a stable, long-term safe shutdown condition is to be demonstrated. This prespecified earthquake level is commonly referred to as the seismic margin earthquake (SME). The Electric Power Research Institute is currently supporting a research project to develop procedures for use by the utilities to allow them to perform nuclear plant seismic margin evaluations. This paper describes the systems-related aspects of these procedures

  19. Disposal systems evaluations and tool development: Engineered Barrier System (EBS) evaluation

    International Nuclear Information System (INIS)

    Rutqvist, Jonny; Liu, Hui-Hai; Steefel, Carl I.; Serrano de Caro, M.A.; Caporuscio, Florie Andre; Birkholzer, Jens T.; Blink, James A.; Sutton, Mark A.; Xu, Hongwu; Buscheck, Thomas A.; Levy, Schon S.; Tsang, Chin-Fu; Sonnenthal, Eric; Halsey, William G.; Jove-Colon, Carlos F.; Wolery, Thomas J.

    2011-01-01

    Key components of the nuclear fuel cycle are short-term storage and long-term disposal of nuclear waste. The latter encompasses the immobilization of used nuclear fuel (UNF) and radioactive waste streams generated by various phases of the nuclear fuel cycle, and the safe and permanent disposition of these waste forms in geological repository environments. The engineered barrier system (EBS) plays a very important role in the long-term isolation of nuclear waste in geological repository environments. EBS concepts and their interactions with the natural barrier are inherently important to the long-term performance assessment of the safety case where nuclear waste disposition needs to be evaluated for time periods of up to one million years. Making the safety case needed in the decision-making process for the recommendation and the eventual embracement of a disposal system concept requires a multi-faceted integration of knowledge and evidence-gathering to demonstrate the required confidence level in a deep geological disposal site and to evaluate long-term repository performance. The focus of this report is the following: (1) Evaluation of EBS in long-term disposal systems in deep geologic environments with emphasis on the multi-barrier concept; (2) Evaluation of key parameters in the characterization of EBS performance; (3) Identification of key knowledge gaps and uncertainties; and (4) Evaluation of tools and modeling approaches for EBS processes and performance. The above topics will be evaluated through the analysis of the following: (1) Overview of EBS concepts for various NW disposal systems; (2) Natural and man-made analogs, room chemistry, hydrochemistry of deep subsurface environments, and EBS material stability in near-field environments; (3) Reactive Transport and Coupled Thermal-Hydrological-Mechanical-Chemical (THMC) processes in EBS; and (4) Thermal analysis toolkit, metallic barrier degradation mode survey, and development of a Disposal Systems

  20. Disposal systems evaluations and tool development : Engineered Barrier System (EBS) evaluation.

    Energy Technology Data Exchange (ETDEWEB)

    Rutqvist, Jonny (LBNL); Liu, Hui-Hai (LBNL); Steefel, Carl I. (LBNL); Serrano de Caro, M. A. (LLNL); Caporuscio, Florie Andre (LANL); Birkholzer, Jens T. (LBNL); Blink, James A. (LLNL); Sutton, Mark A. (LLNL); Xu, Hongwu (LANL); Buscheck, Thomas A. (LLNL); Levy, Schon S. (LANL); Tsang, Chin-Fu (LBNL); Sonnenthal, Eric (LBNL); Halsey, William G. (LLNL); Jove-Colon, Carlos F.; Wolery, Thomas J. (LLNL)

    2011-01-01

    Key components of the nuclear fuel cycle are short-term storage and long-term disposal of nuclear waste. The latter encompasses the immobilization of used nuclear fuel (UNF) and radioactive waste streams generated by various phases of the nuclear fuel cycle, and the safe and permanent disposition of these waste forms in geological repository environments. The engineered barrier system (EBS) plays a very important role in the long-term isolation of nuclear waste in geological repository environments. EBS concepts and their interactions with the natural barrier are inherently important to the long-term performance assessment of the safety case where nuclear waste disposition needs to be evaluated for time periods of up to one million years. Making the safety case needed in the decision-making process for the recommendation and the eventual embracement of a disposal system concept requires a multi-faceted integration of knowledge and evidence-gathering to demonstrate the required confidence level in a deep geological disposal site and to evaluate long-term repository performance. The focus of this report is the following: (1) Evaluation of EBS in long-term disposal systems in deep geologic environments with emphasis on the multi-barrier concept; (2) Evaluation of key parameters in the characterization of EBS performance; (3) Identification of key knowledge gaps and uncertainties; and (4) Evaluation of tools and modeling approaches for EBS processes and performance. The above topics will be evaluated through the analysis of the following: (1) Overview of EBS concepts for various NW disposal systems; (2) Natural and man-made analogs, room chemistry, hydrochemistry of deep subsurface environments, and EBS material stability in near-field environments; (3) Reactive Transport and Coupled Thermal-Hydrological-Mechanical-Chemical (THMC) processes in EBS; and (4) Thermal analysis toolkit, metallic barrier degradation mode survey, and development of a Disposal Systems

  1. Thermionic system evaluated test (TSET) facility description

    Science.gov (United States)

    Fairchild, Jerry F.; Koonmen, James P.; Thome, Frank V.

    1992-01-01

    A consortium of US agencies are involved in the Thermionic System Evaluation Test (TSET) which is being supported by the Strategic Defense Initiative Organization (SDIO). The project is a ground test of an unfueled Soviet TOPAZ-II in-core thermionic space reactor powered by electrical heat. It is part of the United States' national thermionic space nuclear power program. It will be tested in Albuquerque, New Mexico at the New Mexico Engineering Research Institute complex by the Phillips Laboratoty, Sandia National Laboratories, Los Alamos National Laboratory, and the University of New Mexico. One of TSET's many objectives is to demonstrate that the US can operate and test a complete space nuclear power system, in the electrical heater configuration, at a low cost. Great efforts have been made to help reduce facility costs during the first phase of this project. These costs include structural, mechanical, and electrical modifications to the existing facility as well as the installation of additional emergency systems to mitigate the effects of utility power losses and alkali metal fires.

  2. INTEGRATED WATER TREATMENT SYSTEM PERFORMANCE EVALUATION

    International Nuclear Information System (INIS)

    Sexton, R.A.; Meeuwsen, W.E.

    2009-01-01

    This document describes the results of an evaluation of the current Integrated Water Treatment System (IWTS) operation against design performance and a determination of short term and long term actions recommended to sustain IWTS performance. The KW IWTS was designed to treat basin water and maintain basin clarity during fuel retrieval, washing, and packaging activities in the KW Basin. The original design was based on a mission that was limited to handling of KW Basin fuel. The use of the IWTS was extended by the decision to transfer KE fuel to KW to be cleaned and packaged using KW systems. The use was further extended for the packaging of two more Multi-Canister Overpacks (MCOs) containing legacy fuel and scrap. Planning is now in place to clean and package Knock Out Pot (KOP) Material in MCOs using these same systems. Some washing of KOP material in the Primary Cleaning Machine (PCM) is currently being done to remove material that is too small or too large to be included in the KOP Material stream. These plans will require that the IWTS remain operational through a campaign of as many as 30 additional MCOs, and has an estimated completion date in 2012. Recent operation of the IWTS during washing of canisters of KOP Material has been impacted by low pressure readings at the inlet of the P4 Booster Pump. The system provides a low pressure alarm at 10 psig, and low-low pressure interlock at 5 psig. The response to these low readings has been to lower total system flow to between 301 and 315 gpm. In addition, the IWTS operator has been required to operate the system in manual mode and make frequent adjustments to the P4 booster pump speed during PCM washes. The preferred mode of operation is to establish a setpoint of 317 gpm for the P4 pump speed and run IWTS in semi-automatic mode. Based on hydraulic modeling compared to field data presented in this report, the low P4 inlet pressure is attributed to restrictions in the 2-inch KOP inlet hose and in the KOP itself

  3. Evaluation of an adjustable epidemiologic information system.

    Directory of Open Access Journals (Sweden)

    Jiunn-Shyan Julian Wu

    Full Text Available BACKGROUND: In order to facilitate public health response and to achieve early control of infectious disease epidemics, an adjustable epidemiologic information system (AEIS was established in the Taiwan public health network in February 2006. METHODOLOGY/PRINCIPAL FINDINGS: The performance of AEIS for the period 2006 through 2008 was evaluated based on a number of response times (RT and the public health impact. After implementation of the system, the apparent overall shortened RT was mainly due to the shortening of personnel response time (PRT and the time needed to draft a new questionnaire that incurred as personnel-system interface (PSI; PRT dropped from a fluctuating range of 9.8 ∼28.8 days in the first four months to <10 days in the following months and remained low till 2008 (0.88±1.52 days. The PSIs for newly emerged infectious diseases were 2.6 and 3.4 person-hours for H5N1 in 2007 and chikungunya in 2008, respectively, a much improvement from 1142.5 person-hours for SARS in 2003. The duration of each rubella epidemic cluster was evaluated as public health impact and showed a shortening trend (p = 0.019 that concurred with the shortening of PRT from 64.8±47.3 to 25.2±38.2 hours per cluster (p<0.0001. CONCLUSIONS/SIGNIFICANCE: The first evaluation of the novel instrument AEIS that had been used to assist Taiwan's multi-level government for infectious diseases control demonstrated that it was well integrated into the existing public health infrastructure. It provided flexible tools and computer algorithms with friendly interface for timely data collection, integration, and analysis; as a result, it shortened RTs, filled in gaps of personnel lacking sufficient experiences, created a more efficient flow of response, and identified asymptomatic/mild cases early to minimize further spreading. With further development, AEIS is anticipated to be useful in the application of other acute public health events needing immediate

  4. Component aging evaluation with expert systems

    International Nuclear Information System (INIS)

    Wiesemann, J.S.; Maguire, H.T. Jr.

    1988-01-01

    The age degradation of components involves a complex relationship between a variety of variables. These relationships are typically modeled using probabilistic and deterministic analyses. These methods depend upon a formal understanding of the underlying degradation mechanisms and a database of experience which allows statistical analyses to extract numerical trends. At present, not all age degradation mechanisms are adequately modeled and available data for age degradation is in most cases insufficient. In addition, these methods tend to focus upon answers to isolated questions (e.g., What is the component failure rate?) rather than the more pertinent questions concerning operations and maintenance (e.g., should the component be replaced at the next outage). Fortunately, knowledge in the form of personal experience does exist which allows plant personnel to make decisions concerning operations and maintenance. This knowledge can be modeled using expert systems. This paper discusses CAGES (Component Aging Expert System). It combines expert rules (heuristics), probabilistic models, and deterministic models to make evaluations of component aging; predict the implications for component life extension, operational readiness, maintenance effectiveness, and safety, and make recommendations for maintenance and operation

  5. Preliminary application of a novel algorithm to monitor changes in pre-flight total peripheral resistance for prediction of post-flight orthostatic intolerance in astronauts

    Science.gov (United States)

    Arai, Tatsuya; Lee, Kichang; Stenger, Michael B.; Platts, Steven H.; Meck, Janice V.; Cohen, Richard J.

    2011-04-01

    Orthostatic intolerance (OI) is a significant challenge for astronauts after long-duration spaceflight. Depending on flight duration, 20-80% of astronauts suffer from post-flight OI, which is associated with reduced vascular resistance. This paper introduces a novel algorithm for continuously monitoring changes in total peripheral resistance (TPR) by processing the peripheral arterial blood pressure (ABP). To validate, we applied our novel mathematical algorithm to the pre-flight ABP data previously recorded from twelve astronauts ten days before launch. The TPR changes were calculated by our algorithm and compared with the TPR value estimated using cardiac output/heart rate before and after phenylephrine administration. The astronauts in the post-flight presyncopal group had lower pre-flight TPR changes (1.66 times) than those in the non-presyncopal group (2.15 times). The trend in TPR changes calculated with our algorithm agreed with the TPR trend calculated using measured cardiac output in the previous study. Further data collection and algorithm refinement are needed for pre-flight detection of OI and monitoring of continuous TPR by analysis of peripheral arterial blood pressure.

  6. Evaluation System for Pesticides (ESPE). 1. Agricultural pesticides

    NARCIS (Netherlands)

    Emans HJB; Beek MA; Linders JBHJ

    1992-01-01

    In this report a risk assessment or evaluation system for agricultural pesticides is presented, which estimates the hazards for man and environment resulting from the use of these pesticides. The evaluation system has also been placed within the context of the Uniform System for the Evaluation of

  7. World Integrated Nuclear Evaluation System: Model documentation

    International Nuclear Information System (INIS)

    1991-12-01

    The World Integrated Nuclear Evaluation System (WINES) is an aggregate demand-based partial equilibrium model used by the Energy Information Administration (EIA) to project long-term domestic and international nuclear energy requirements. WINES follows a top-down approach in which economic growth rates, delivered energy demand growth rates, and electricity demand are projected successively to ultimately forecast total nuclear generation and nuclear capacity. WINES could be potentially used to produce forecasts for any country or region in the world. Presently, WINES is being used to generate long-term forecasts for the United States, and for all countries with commercial nuclear programs in the world, excluding countries located in centrally planned economic areas. Projections for the United States are developed for the period from 2010 through 2030, and for other countries for the period starting in 2000 or 2005 (depending on the country) through 2010. EIA uses a pipeline approach to project nuclear capacity for the period between 1990 and the starting year for which the WINES model is used. This approach involves a detailed accounting of existing nuclear generating units and units under construction, their capacities, their actual or estimated time of completion, and the estimated date of retirements. Further detail on this approach can be found in Appendix B of Commercial Nuclear Power 1991: Prospects for the United States and the World

  8. Usability Evaluation of a Web-Based Learning System

    Science.gov (United States)

    Nguyen, Thao

    2012-01-01

    The paper proposes a contingent, learner-centred usability evaluation method and a prototype tool of such systems. This is a new usability evaluation method for web-based learning systems using a set of empirically-supported usability factors and can be done effectively with limited resources. During the evaluation process, the method allows for…

  9. Evaluation Criteria for the Educational Web-Information System

    Science.gov (United States)

    Seok, Soonhwa; Meyen, Edward; Poggio, John C.; Semon, Sarah; Tillberg-Webb, Heather

    2008-01-01

    This article addresses how evaluation criteria improve educational Web-information system design, and the tangible and intangible benefits of using evaluation criteria, when implemented in an educational Web-information system design. The evaluation criteria were developed by the authors through a content validation study applicable to…

  10. Realization of economic evaluation expert system for uranium mine project

    International Nuclear Information System (INIS)

    Wang Haifeng

    1993-01-01

    By studying the EVALUATOR, economic evaluation expert system of uranium mine project, the theoretical fundamentals of expert system, principle of inference mechanism, implementation of knowledge base, realization of explanation mechanism, acquisition of domain knowledge and representation of knowledge were described, especially the subjective Bayes approach for inexact reasoning problem used in EVALUATOR was discussed in detail

  11. Disability Evaluation Systems Analysis and Research Annual Report 2015

    Science.gov (United States)

    2016-03-21

    Army and Air Force had higher percentages of reserve component disability evaluations, likely due to the inclusion of National Guard service members...Annual Report 2015 Disability Evaluation Systems Analysis and Research Prepared by Accession Medical Standards Analysis and Research Activity...Preventive Medicine Branch Walter Reed Army Institute of Research Silver Spring, Maryland Disability Evaluation Systems Analysis and Research

  12. Disability Evaluation System Analysis and Research Annual Report 2015

    Science.gov (United States)

    2016-03-11

    Inclusion of laboratory and diagnostic information on the medical condition or injury that precipitated the disability evaluation in each service’s...Annual Report 2015 Disability Evaluation Systems Analysis and Research Prepared by Accession Medical Standards Analysis and Research Activity...Preventive Medicine Branch Walter Reed Army Institute of Research Silver Spring, Maryland Disability Evaluation Systems Analysis and Research

  13. Making Sense of Alternative Assessment in a Qualitative Evaluation System

    Science.gov (United States)

    Rojas Serrano, Javier

    2017-01-01

    In a Colombian private English institution, a qualitative evaluation system has been incorporated. This type of evaluation poses challenges to students who have never been evaluated through a system that eliminates exams or quizzes and, as a consequence, these students have to start making sense of it. This study explores the way students face the…

  14. Applying Knowledge Management in Teacher Evaluation Systems

    Science.gov (United States)

    Essandoh, Albert

    2013-01-01

    Teacher evaluations are underused in public schools, resulting in the loss of knowledge critical to professional development. Knowledge management (KM) theory offers approaches that can lead to improvements in the effectiveness of evaluations and teacher performance. This multiple case study of 9 campuses in an exemplary school district…

  15. Urban Transportation Planning Short Course: Evaluation of Alternative Transportation Systems.

    Science.gov (United States)

    Federal Highway Administration (DOT), Washington, DC.

    This urban transportation pamphlet delves into the roles of policy groups and technical staffs in evaluating alternative transportation plans, evaluation criteria, systems to evaluate, and evaluation procedures. The introduction admits the importance of subjective, but informed, judgment as an effective tool in weighing alternative transportation…

  16. Light water reactor safeguards system evaluation

    International Nuclear Information System (INIS)

    Varnado, G.B.; Ericson, D.M. Jr.; Bennett, H.A.; Hulme, B.L.; Daniel, S.L.

    1978-01-01

    A methodology for assessing the effectiveness of safeguards systems was developed in this study and was applied to a typical light water reactor plant. The relative importance of detection systems, barriers, response forces and other safeguards system components was examined in extensive parameter variation studies. (author)

  17. A Design for the Evaluation of Management Information Systems.

    Science.gov (United States)

    Spuck, Dennis W.; Bozeman, William C.

    1980-01-01

    This paper has presented a model for the evaluation of management information systems. The three levels of information considered were actual, perceptual, and attitudinal. The dimensions of evaluation discussed were function, utilization, and effects. (Author/IRT)

  18. Uninhabited Traffic Management System Evaluator (UTME), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The key innovation of this effort is the development of an Uninhabited Aerial System (UAS) Traffic Manager Evaluator (UTME) specifically targeted at evaluating...

  19. Pervious Pavement System Evaluation- Abstract 1

    Science.gov (United States)

    Porous pavement is a low impact development stormwater control. The Urban Watershed Management Branch is evaluating interlocking concrete pavers as a popular implementation. The pavers themselves are impermeable, but the spaces between the pavers are backfilled with washed, gra...

  20. Evaluation of the new respiratory gating system

    Science.gov (United States)

    Shi, Chengyu; Tang, Xiaoli; Chan, Maria

    2018-01-01

    Objective The newly released Respiratory Gating for Scanners (RGSC; Varian Medical Systems, Palo Alto, CA, USA) system has limited existing quality assurance (QA) protocols and pertinent publications. Herein, we report our experiences of the RGSC system acceptance and QA. Methods The RGSC system integration was tested with peripheral equipment, spatial reproducibility, and dynamic localization accuracy for regular and irregular breathing patterns, respectively. A QUASAR Respiratory Motion Phantom and a mathematical fitting method were used for data acquisition and analysis. Results The results showed that the RGSC system could accurately measure regular motion periods of 3–10 s. For irregular breathing patterns, differences from the existing Real-time Position Management (RPM; Varian Medical Systems, Palo Alto, CA) system were observed. For dynamic localization measurements, the RGSC system showed 76% agreement with the programmed test data within ±5% tolerance in terms of fitting period. As s comparison, the RPM system showed 66% agreement within ±5% tolerance, and 65% for the RGSC versus RPM measurements. Conclusions New functions and positioning accuracy improve the RGSC system’s ability to achieve higher dynamic treatment precision. A 4D phantom is helpful for the QA tests. Further investigation is required for the whole RGSC system performance QA. PMID:29722356

  1. Evaluating energy saving system of data centers based on AHP and fuzzy comprehensive evaluation model

    Science.gov (United States)

    Jiang, Yingni

    2018-03-01

    Due to the high energy consumption of communication, energy saving of data centers must be enforced. But the lack of evaluation mechanisms has restrained the process on energy saving construction of data centers. In this paper, energy saving evaluation index system of data centers was constructed on the basis of clarifying the influence factors. Based on the evaluation index system, analytical hierarchy process was used to determine the weights of the evaluation indexes. Subsequently, a three-grade fuzzy comprehensive evaluation model was constructed to evaluate the energy saving system of data centers.

  2. Experimental Evaluation of Mountain Bike Suspension Systems

    Directory of Open Access Journals (Sweden)

    J. Titlestad

    2003-01-01

    Full Text Available A significant distinction between competitive mountain bikes is whether they have a suspension system. Research studies indicate that a suspension system gives advantages, but it is difficult to quantify the benefits because they depend on so many variables, including the physiology and psychology of the cyclist, the roughness of the track and the design of the suspension system. A laboratory based test rig has been built that allows the number of variables in the system to be reduced and test conditions to be controlled. The test rig simulates regular impacts of the rear wheel with bumps in a rolling road. The physiological variables of oxygen consumption and heart rate were measured, together with speeds and forces at various points in the system. Physiological and mechanical test results both confirm a significant benefit in using a suspension system on the simulated rough track, with oxygen consumption reduced by around 30 % and power transmitted through the pedals reduced by 30 % to 60 %.

  3. performance evaluation of sprinkler irrigation system at mambilla

    African Journals Online (AJOL)

    HOD

    ratio (DPR), irrigation productivity (IP), labour requirements and water quality. Standard procedure was ... The exchangeable cations analysis of Kakara irrigation ... Keywords: Tea, irrigation System, Performance Evaluation. 1. INTRODUCTION.

  4. Advanced public transportation systems : evaluation guidelines

    Science.gov (United States)

    1994-01-01

    The Federal Transit Administration has developed the Advanced Public Transportation Systems (APTS) Program which is an integral part of the overall U.S. DOT Intelligent Vehicle Highway Systems (IVHS) effort. A major aim of the APTS Program is to prom...

  5. Reverse electrodialysis : evaluation of suitable electrode systems

    NARCIS (Netherlands)

    Veerman, J.; Saakes, M.; Metz, S. J.; Harmsen, G. J.

    Reverse electrodialysis (RED) is a method for directly extracting electrical energy from salinity gradients, especially from sea and river water. For the commercial implementation of RED, the electrode system is a key component. In this paper, novel electrode systems for RED were compared with

  6. Evaluation of an Automated Keywording System.

    Science.gov (United States)

    Malone, Linda C.; And Others

    1990-01-01

    Discussion of automated indexing techniques focuses on ways to statistically document improvements in the development of an automated keywording system over time. The system developed by the Joint Chiefs of Staff to automate the storage, categorization, and retrieval of information from military exercises is explained, and performance measures are…

  7. Classroom Evaluation of a Rapid Prototyping System.

    Science.gov (United States)

    Tennyson, Stephen A.; Krueger, Thomas J.

    2001-01-01

    Introduces rapid prototyping which creates virtual models through a variety of automated material additive processes. Relates experiences using JP System 5 in freshman and sophomore engineering design graphics courses. Analyzes strengths and limitations of the JP System 5 and discusses how to use it effectively. (Contains 15 references.)…

  8. Evaluation of decision support systems for nuclear accidents

    International Nuclear Information System (INIS)

    Sdouz, G.; Mueck, K.

    1998-05-01

    In order to adopt countermeasures to protect the public after an accident in a nuclear power plant in an appropriate and optimum way, decision support systems offer a valuable assistance in supporting the decision maker in choosing and optimizing protective actions. Such decision support systems may range from simple systems to accumulate relevant parameters for the evaluation of the situation over prediction models for the rapid evaluation of the dose to be expected to systems which permit the evaluation and comparison of possible countermeasures. Since the establishment of a decision support systems obviously is also required in Austria, an evaluation of systems available or in the state of development in other countries or unions was performed. The aim was to determine the availability of decision support systems in various countries and to evaluate them with regard to depth and extent of the system. The evaluation showed that in most industrialized countries the requirement for a decision support system was realized, but in only few countries actual systems are readily available and operable. Most systems are limited to early phase consequences, i.e. dispersion calculations of calculated source terms and the estimation of exposure in the vicinity of the plant. Only few systems offer the possibility to predict long-term exposures by ingestion. Few systems permit also an evaluation of potential countermeasures, in most cases, however, limited to a few short-term countermeasures. Only one system which is presently not operable allows the evaluation of a large number of agricultural countermeasures. In this report the different systems are compared. The requirements with regard to an Austrian decision support system are defined and consequences for a possible utilization of a DSS or parts thereof for the Austrian decision support system are derived. (author)

  9. thermal power stations' reliability evaluation in a hydrothermal system

    African Journals Online (AJOL)

    Dr Obe

    A quantitative tool for the evaluation of thermal power stations reliability in a hydrothermal system is presented. ... (solar power); wind (wind power) and the rest, thermal power and ... probability of a system performing its function adequately for ...

  10. Global Positioning System receiver evaluation results

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, R.H.

    1993-09-01

    A Sandia project currently uses an outdated Magnavox 6400 Global Positioning System (GPS) receiver as the core of its navigation system. The goal of this study was to analyze the performance of the current GPS receiver compared to newer, less expensive models and to make recommendations on how to improve the performance of the overall navigation system. This paper discusses the test methodology used to experimentally analyze the performance of different GPS receivers, the test results, and recommendations on how an upgrade should proceed. Appendices contain detailed information regarding the raw data, test hardware, and test software.

  11. Systems Evaluation at the Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [Steven Winter Associates, Inc., Norwalk, CT (United States); Puttagunta, S. [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems,this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  12. Systems Evaluation at the Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    J. Williamson and S. Puttagunta

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems, this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  13. Evaluation of the TRIMAX 280 System

    National Research Council Canada - National Science Library

    Kalberer, Jennifer

    2002-01-01

    .... A series of five JP-8 pool fires of 2500-sq ft, three JP-8 3500-sq ft pool fires with F100 engine nacelle mockup, and one JP-8 700-sq ft with F100 engine nacelle mockup were used to evaluate the 90...

  14. Evaluation of a Cyber Security System for Hospital Network.

    Science.gov (United States)

    Faysel, Mohammad A

    2015-01-01

    Most of the cyber security systems use simulated data in evaluating their detection capabilities. The proposed cyber security system utilizes real hospital network connections. It uses a probabilistic data mining algorithm to detect anomalous events and takes appropriate response in real-time. On an evaluation using real-world hospital network data consisting of incoming network connections collected for a 24-hour period, the proposed system detected 15 unusual connections which were undetected by a commercial intrusion prevention system for the same network connections. Evaluation of the proposed system shows a potential to secure protected patient health information on a hospital network.

  15. STRATEGY FOR EVALUATION AND SELECTION OF SYSTEMS FOR ELECTRONIC LEARNING

    OpenAIRE

    Dubravka Mandušić; Lucija Blašković

    2012-01-01

    Today`s technology supported and accelerated learning time requires constant and continuous acquisition of new knowledge. On the other hand, it does not leave enough time for additional education. Increasing number of E-learning systems, withdraws a need for precise evaluation of functionality that those systems provide; so they could be reciprocally compared. While implementing new systems for electronic learning, it is very important to pre-evaluate existing systems in order to ...

  16. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  17. Automatic Tracking Evaluation and Development System (ATEDS)

    Data.gov (United States)

    Federal Laboratory Consortium — The heart of the ATEDS network consists of four SGI Octane computers running the IRIX operating system and equipped with V12 hardware graphics to support synthetic...

  18. Evaluation of two typical distributed energy systems

    Science.gov (United States)

    Han, Miaomiao; Tan, Xiu

    2018-03-01

    According to the two-natural gas distributed energy system driven by gas engine driven and gas turbine, in this paper, the first and second laws of thermodynamics are used to measure the distributed energy system from the two parties of “quantity” and “quality”. The calculation results show that the internal combustion engine driven distributed energy station has a higher energy efficiency, but the energy efficiency is low; the gas turbine driven distributed energy station energy efficiency is high, but the primary energy utilization rate is relatively low. When configuring the system, we should determine the applicable natural gas distributed energy system technology plan and unit configuration plan according to the actual load factors of the project and the actual factors such as the location, background and environmental requirements of the project. “quality” measure, the utilization of waste heat energy efficiency index is proposed.

  19. VIPS: A simulator for platoon system evaluation

    OpenAIRE

    GUERIAU, Maxime; DAFFLON, Baudouin; GECHTER, Franck

    2017-01-01

    Development of intelligent behaviors for vehicles has to cope with rigorous specifications. Many tests are performed for verification, validation and a detailed study of resulting be- haviors. In this workflow, testing algorithms with real vehicles is a cornerstone step in developing new intelligent features for future transportation systems. This step requires a lot of experiments before efficiently set up embedded autonomous systems. However, the development of such tests is not linear and ...

  20. An Evaluation Methodology for Protocol Analysis Systems

    Science.gov (United States)

    2007-03-01

    Main Memory Requirement NS: Needham-Schroeder NSL: Needham-Schroeder-Lowe OCaml : Objective Caml POSIX: Portable Operating System...methodology is needed. A. PROTOCOL ANALYSIS FIELD As with any field, there is a specialized language used within the protocol analysis community. Figure...ProVerif requires that Objective Caml ( OCaml ) be installed on the system, OCaml version 3.09.3 was installed. C. WINDOWS CONFIGURATION OS

  1. AN INTERIM REPORT ON SOFT SYSTEMS EVALUATION

    Directory of Open Access Journals (Sweden)

    Viljem Rupnik

    2011-02-01

    Full Text Available As application areas rapidly grow beyond the theoretical framework of fundamental decision theory we are very often temptated to see whether or not soft systems may promise some efficient modelling of real life problems. The pioneering bust towards soft systems methodology has come from the needs of mathematical sociology. Its contemporary definition as well as its applied architecture have been dealt with as in a paper proposed.

  2. Evaluating and projecting the European security system

    International Nuclear Information System (INIS)

    Dean, J.

    1991-01-01

    Components of the new European security system are described taking into account the new policy making and possibilities to resolve conflicts. Programmes for political and economic integration and co-operation managed by the European Community will provide main positive content of the new European security system. An insight of the future of nuclear armaments in Europe is included together with confidence building measure and the role of NATO

  3. The Integrated Air Transportation System Evaluation Tool

    Science.gov (United States)

    Wingrove, Earl R., III; Hees, Jing; Villani, James A.; Yackovetsky, Robert E. (Technical Monitor)

    2002-01-01

    Throughout U.S. history, our nation has generally enjoyed exceptional economic growth, driven in part by transportation advancements. Looking forward 25 years, when the national highway and skyway systems are saturated, the nation faces new challenges in creating transportation-driven economic growth and wealth. To meet the national requirement for an improved air traffic management system, NASA developed the goal of tripling throughput over the next 20 years, in all weather conditions while maintaining safety. Analysis of the throughput goal has primarily focused on major airline operations, primarily through the hub and spoke system.However, many suggested concepts to increase throughput may operate outside the hub and spoke system. Examples of such concepts include the Small Aircraft Transportation System, civil tiltrotor, and improved rotorcraft. Proper assessment of the potential contribution of these technologies to the domestic air transportation system requires a modeling capability that includes the country's numerous smaller airports, acting as a fundamental component of the National Air space System, and the demand for such concepts and technologies. Under this task for NASA, the Logistics Management Institute developed higher fidelity demand models that capture the interdependence of short-haul air travel with other transportation modes and explicitly consider the costs of commercial air and other transport modes. To accomplish this work, we generated forecasts of the distribution of general aviation based aircraft and GA itinerant operations at each of nearly 3.000 airport based on changes in economic conditions and demographic trends. We also built modules that estimate the demand for travel by different modes, particularly auto, commercial air, and GA. We examined GA demand from two perspectives: top-down and bottom-up, described in detail.

  4. Performance evaluation of communication systems via importance sampling

    NARCIS (Netherlands)

    Remondo Bueno, D.

    2000-01-01

    In the design and development of telecommunication systems, the preparation of experiments can be made more effective by predicting the system performance and its dependence on the different system parameters. This can be done by modeling the system and using performance evaluation methods. This

  5. Evaluation of an advanced rotor bore examination system

    International Nuclear Information System (INIS)

    Alford, J.W.

    1990-01-01

    Evaluations of in-service turbine-generator rotor forgings are often based on an ultrasonic examination of the near-bore region. A portable rotor bore examination system has been developed that provides discontinuity characterization required for a thorough rotor evaluation. This automated system, its procedures and operations personnel have now been qualified for full-scale field application. System development has benefited from merging several technologies with new methods for precise alignment of the drive unit, calibration block and rotor. The system runs a custom interactive software package that allows for flexible calibration and motion control as well as data acquisition and manipulation. A comprehensive evaluation procedure was developed for system qualification using test specimens with natural and artificial reflectors, including a unique fatigue-crack block. Following a discussion of the system features, this paper discusses the system evaluation based on this procedure

  6. Quantitative evaluation of the RETIMAC system

    International Nuclear Information System (INIS)

    Bain, E.E.; Fisher, R.H.; Gozani, T.; Harris, L. Jr.; Kendrick, H.; Kull, L.A.; Murri, E.L.; Ollivier, R.T.; Simmons, G.L.

    1975-01-01

    One means of raising the degree of protection afforded strategic special nuclear materials against theft and diversion is the installation of Real Time Material Control (RETIMAC) systems. The ability of RETIMAC to detect any covert attempt to steal special nuclear materials in a time frame that is adequate to contain subcritical quantities of special nuclear material within the boundaries of the material protection system and to maintain current knowledge of the quantity and location of all strategic special nuclear material was tested. A commercial-scale mixed oxide fuel fabrication plant was chosen for the study. (LK)

  7. Evaluation of Various Navigation System Concepts

    Science.gov (United States)

    1982-03-01

    Naigatimon aar01 N DAutomatic x xx Parallel 0fn x x x x x’ "OLeg t dung. n Mrankuhld M ni raia x N x to~g TAN is I OmuI,2 2mN 0 x "to - - -x...and must permit design of indicators and controls which can be directly interpreted or operated by the pilot at his normal station aboard the...the responsibility of control. The organization that controls the system can theoretically limit access to the system. Because VOVO/DME, Loran-C, and

  8. MSFC Skylab electrical power systems mission evaluation

    Science.gov (United States)

    Woosley, A. P.

    1974-01-01

    The design, development, and operation of the Skylab electrical power system are discussed. The electrical systems for the airlock module of the orbital workshop and the Apollo telescope mount are described. Skylab is considered an integral laboratory, however, both cluster and module hardware distinct sections are included. Significant concept and requirement evolution, testing, and modifications resulting from tests are briefly summarized to aid in understanding the launch configuration description and the procedures and performance discussed for in-orbit operation. Specific problems encountered during Skylab orbital missions are analyzed.

  9. Expert evaluation in NPP safety important systems licensing process

    International Nuclear Information System (INIS)

    Mikhail, A Yastrebenetsky; Vasilchenko, V.N.

    2001-01-01

    Expert evaluation of nuclear power plant safety important systems modernization is an integral part of these systems licensing process. The paper contains some aspects of this evaluation which are based on Ukrainian experience of VVER-1000 and VVER-440 modernization. (authors)

  10. Evaluation of man-machine systems - methods and problems

    International Nuclear Information System (INIS)

    1985-01-01

    The symposium gives a survey of the methods of evaluation which permit as quantitive an assessment as possible of the collaboration between men and machines. This complex of problems is of great current significance in many areas of application. The systems to be evaluated are aircraft, land vehicles and watercraft as well as process control systems. (orig./GL) [de

  11. Expert evaluation in NPP safety important systems licensing process

    Energy Technology Data Exchange (ETDEWEB)

    Mikhail, A Yastrebenetsky; Vasilchenko, V.N. [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety (Ukraine)

    2001-07-01

    Expert evaluation of nuclear power plant safety important systems modernization is an integral part of these systems licensing process. The paper contains some aspects of this evaluation which are based on Ukrainian experience of VVER-1000 and VVER-440 modernization. (authors)

  12. Manipulator system man-machine interface evaluation program. [technology assessment

    Science.gov (United States)

    Malone, T. B.; Kirkpatrick, M.; Shields, N. L.

    1974-01-01

    Application and requirements for remote manipulator systems for future space missions were investigated. A manipulator evaluation program was established to study the effects of various systems parameters on operator performance of tasks necessary for remotely manned missions. The program and laboratory facilities are described. Evaluation criteria and philosophy are discussed.

  13. IBM PC/IX operating system evaluation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  14. NNWSI project information management system concepts evaluation report. Final report

    International Nuclear Information System (INIS)

    1986-08-01

    This report is intended as a first step in developing detailed information management system specifications for the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. The current state of information management at the NNWSI Project level is investigated and an information management system (IMS) is proposed. The IMS as it relates to aspects of Project and records management is discussed. Information management concepts and prospective IMS system components are investigated. Concepts and system components include: indexing, searching, retrieval, data base management system technology, computers, storage media, computer-assisted retrieval (CAR) of microfilm, electronic imaging-based systems, optical character recognition, and communications. Performance criteria and desirable system attributes applicable to the IMS are discussed. Six conceptual system approaches capable of satisfying the performance criteria are defined. System approaches include: fully centralized microfilm system based on CAR retrieval (Approach 1), partially distributed microfilm system based on CAR retrieval (Approach 2), fully distributed microfilm system based on CAR retrieval (Approach 3), fully centralized optical disk system based on electronic image and full-text retrieval (Approach 4), partially distributed optical system based on electron image and full-text retrieval (Approach 5), and fully distributed optical disk system based on electronic image and full-text retrieval (Approach 6). Technical and cost considerations associated with the six conceptual approaches are evaluated. Technical evaluation results indicate Approach 4 is the best conceptual approach, and cost evaluation results show no significant differences among approaches. On the basis of the evaluation, Approach 4 is recommended

  15. A new evaluation platform for Navigation systems

    DEFF Research Database (Denmark)

    Sejerøe, Thomas Hanefeld; Poulsen, Niels Kjølstad; Ravn, Ole

    2005-01-01

    The KALMTOOL 2 toolbox is a set of MATLAB tools for state estimation for nonlinear systems. The toolbox contains functions for extended Kalman filtering as well as for two new filters called the DD1 filter and the DD2 filter. It also contains function for Uncented Kalman filters as well as three ...

  16. Evaluating Library Staff: A Performance Appraisal System.

    Science.gov (United States)

    Belcastro, Patricia

    This manual provides librarians and library managers with a performance appraisal system that measures staff fairly and objectively and links performance to the goals of the library. The following topics are addressed: (1) identifying expectations for quality service or standards of performance; (2) the importance of a library's code of service,…

  17. Distribution system reliability evaluation using credibility theory

    African Journals Online (AJOL)

    Xufeng Xu, Joydeep Mitra

    have found that credibility theory, which broadens the scope of fuzzy set theory, is an effective tool for representing fuzzy events, and have developed a theoretical .... Based on the status of switches, the distribution system can be divided into multiple SPSS, which are connected with tie switches. For example, SPSS.

  18. Study of system safety evaluation on LTO of national project. Thermal fatigue evaluation of piping systems

    International Nuclear Information System (INIS)

    Kasahara, Naoto; Itoh, Takamoto; Okazaki, Masakazu; Okuda, Yukihiko; Kamaya, Masayuki; Nakamura, Akira; Nakamura, Hitoshi; Machida, Hideo

    2012-01-01

    Nuclear piping has various kinds of thermal fatigue failure modes. Main causes of thermal loads are structural responses to fluid temperature changes during plant operation. These phenomena have complex mechanisms and so many patterns, that their problems still occur even though well-known issues. To prevent thermal fatigue due to above thermal loads, the JSME guideline is adopted. Both thermal load and fatigue failure mechanism have been investigated and summarized into the knowledgebase. Numerical simulation methods for thermal fatigue evaluation were studied to replace structural tests. Theses knowledge was utilized to validate and justify the JSME guideline. Furthermore, new studies have been launched to apply above knowledge to enhance plant system safety. (author)

  19. Design Concept Evaluation Using System Throughput Model

    International Nuclear Information System (INIS)

    Sequeira, G.; Nutt, W. M.

    2004-01-01

    The U.S. Department of Energy (DOE) Office of Civilian Radioactive Waste Management (OCRWM) is currently developing the technical bases to support the submittal of a license application for construction of a geologic repository at Yucca Mountain, Nevada to the U.S. Nuclear Regulatory Commission. The Office of Repository Development (ORD) is responsible for developing the design of the proposed repository surface facilities for the handling of spent nuclear fuel and high level nuclear waste. Preliminary design activities are underway to sufficiently develop the repository surface facilities design for inclusion in the license application. The design continues to evolve to meet mission needs and to satisfy both regulatory and program requirements. A system engineering approach is being used in the design process since the proposed repository facilities are dynamically linked by a series of sub-systems and complex operations. In addition, the proposed repository facility is a major system element of the overall waste management process being developed by the OCRWM. Such an approach includes iterative probabilistic dynamic simulation as an integral part of the design evolution process. A dynamic simulation tool helps to determine if: (1) the mission and design requirements are complete, robust, and well integrated; (2) the design solutions under development meet the design requirements and mission goals; (3) opportunities exist where the system can be improved and/or optimized; and (4) proposed changes to the mission, and design requirements have a positive or negative impact on overall system performance and if design changes may be necessary to satisfy these changes. This paper will discuss the type of simulation employed to model the waste handling operations. It will then discuss the process being used to develop the Yucca Mountain surface facilities model. The latest simulation model and the results of the simulation and how the data were used in the design

  20. Management Control Systems, Evaluative Style, and Behaviour : Exploring the Concept and Behavioural Consequences of Evaluative Style

    NARCIS (Netherlands)

    J. Noeverman (Jan)

    2007-01-01

    textabstractOrganisations develop and implement performance measurement and performance evaluation systems to motivate employees to take actions that -in the end- improve organisational (financial) performance. But do these systems really influence employee behaviour as intended? This thesis shows

  1. Document Level Assessment of Document Retrieval Systems in a Pairwise System Evaluation

    Science.gov (United States)

    Rajagopal, Prabha; Ravana, Sri Devi

    2017-01-01

    Introduction: The use of averaged topic-level scores can result in the loss of valuable data and can cause misinterpretation of the effectiveness of system performance. This study aims to use the scores of each document to evaluate document retrieval systems in a pairwise system evaluation. Method: The chosen evaluation metrics are document-level…

  2. A computer program to evaluate optical systems

    Science.gov (United States)

    Innes, D.

    1972-01-01

    A computer program is used to evaluate a 25.4 cm X-ray telescope at a field angle of 20 minutes of arc by geometrical analysis. The object is regarded as a point source of electromagnetic radiation, and the optical surfaces are treated as boundary conditions in the solution of the electromagnetic wave propagation equation. The electric field distribution is then determined in the region of the image and the intensity distribution inferred. A comparison of wave analysis results and photographs taken through the telescope shows excellent agreement.

  3. Performance evaluation of computer and communication systems

    CERN Document Server

    Le Boudec, Jean-Yves

    2011-01-01

    … written by a scientist successful in performance evaluation, it is based on his experience and provides many ideas not only to laymen entering the field, but also to practitioners looking for inspiration. The work can be read systematically as a textbook on how to model and test the derived hypotheses on the basis of simulations. Also, separate parts can be studied, as the chapters are self-contained. … the book can be successfully used either for self-study or as a supplementary book for a lecture. I believe that different types of readers will like it: practicing engineers and resea

  4. Development of expert evaluation system for advanced nuclear power stations

    International Nuclear Information System (INIS)

    Yang Mengjia; Ren Junsheng; Zhou Zhiwei; Zhang Qi; Zhu Shutang

    2005-01-01

    The wheels of the nuclear power industry in China are going to roll on the fast rails soon: It is important to establish an expert evaluation system for optimally selecting new types of NPPs in the future based on scientific evaluation. Under such a background, an expert evaluation system is developed to evaluate Various types of NPPs for the following two decades by taking into account the advices of selected top specialists in Chinese nuclear power industry, and by adopting different evaluation methods. The evaluation system is designed to use the database-MS-SQL Server or Oracle for manipulating experts' knowledge and objective data for scaling NPPs by user-selected evaluation methods for evaluating NPPs. The system includes two subsystems: one is called the Data Management Module and the other called the Evaluation Arithmetic Module. The Data Management Module is used to manage expert knowledge in forms of item marks of the NPPs given by experts of nuclear engineering. The Evaluation Arithmetic Module is used to analyze and deal with the evaluation based on the data in the Database by certain designed evaluation method, and to provide the evaluation results. Based on the users' selection, the evaluation of the NPPs is processed, and the results can be dynamically listed in table or displayed in graphics. So it can be used as a consulting tool to help users make optimal selection of prospective NPPs. The system is developed in architecture of the mixture framework C/S(Client/Server) and B/S(Browse/Server), thus is safe, advanced, extensible and user- friendly. The present system is computer network based, so it can be used not only in personal PC and local network, but also in the Web Server which can be browsed by remote users. To develop such an evaluation system is an initiative R and D project in Chinese nuclear R and D activities. Although the evaluation system is far from perfect, however, the preliminary evaluation results produced by the evaluation

  5. STRATEGY FOR EVALUATION AND SELECTION OF SYSTEMS FOR ELECTRONIC LEARNING

    Directory of Open Access Journals (Sweden)

    Dubravka Mandušić

    2012-12-01

    Full Text Available Today`s technology supported and accelerated learning time requires constant and continuous acquisition of new knowledge. On the other hand, it does not leave enough time for additional education. Increasing number of E-learning systems, withdraws a need for precise evaluation of functionality that those systems provide; so they could be reciprocally compared. While implementing new systems for electronic learning, it is very important to pre-evaluate existing systems in order to select the one that meets all defined parameters, with low costs/investment. Proper evaluation can save time and money.

  6. Students Prefer Audience Response System for Lecture Evaluation

    Directory of Open Access Journals (Sweden)

    Joseph W Turban

    2011-12-01

    Full Text Available Objectives: Student evaluation of courses is an important component of overall course evaluation. The extent of student participation in the evaluation may be related to the ease of the evaluation process. The standard evaluation format is a paper form. This study examines medical students preference of utilizing Audience Response System compared to a paper method. Methods: Following several medical school lectures, students were queried if they preferred Audience Response System versus a paper method, and if they would prefer using Audience Response System more for future course evaluations. Results: 391 students were queried. Overall response rate was 94%. Using a five point Likert scale, 299 out of 361 (82% responded they agreed, or strongly agreed with the statement “We should use ARS more. . .” When asked which format they preferred to use for evaluation, 299/367 (81% responded Audience Response System, 31 (8% preferred paper, and 37 (10% were not sure, or had no opinion (chi squared = 378.936, df2, p<0.0001. Conclusion: The medical students surveyed showed a strong preference for utilizing Audience Response System as a course evaluation modality, and desired its continued use in medical school. Audience Response System should be pursued as a lecture evaluation modality, and its use in medical school education should be encouraged.

  7. MITLL 2015 Language Recognition Evaluation System Description

    Science.gov (United States)

    2016-01-27

    912 8.18 qsl-rus Russian 2021 37.80 ara-ary Maghrebi 919 46.91 spa-car Carib. Spa. 194 30.59 ara-arz Egyptian 440 97.27 spa-eur Eur. Spa. 366 8.55...qsl-pol Polish 695 32.14 ara-arb MSA 912 8.18 qsl-rus Russian 2021 37.80 ara-ary Maghrebi 919 46.91 spa-car Carib. Spa. 194 30.59 ara-arz Egyptian ...BOTTLENECK I-VECTOR SYSTEM (BNF1) The Deep Neural Network architecture that we used for this system was composed of seven hidden layers. The sixth

  8. Devices for Evaluating Imaging Systems. Chapter 15

    Energy Technology Data Exchange (ETDEWEB)

    Demirkaya, O.; Al-Mazrou, R. [Department of Biomedical Physics, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia)

    2014-12-15

    A quality management system (QMS) has three main components: (a) Quality assurance (QA); (b) Quality improvement; (c) Quality control (QC). The aim of a QMS is to ensure that the deliverables meet the requirements set forth by the users. The deliverables can be, in general, all the services provided in a nuclear medicine department, and the diagnostic imaging services in particular. In this section, the primary focus is the diagnostic imaging equipment and images produced by them.

  9. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Neil Todreas; Pavel Hejzlar

    2008-06-30

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

  10. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    International Nuclear Information System (INIS)

    Neil Todreas; Pavel Hejzlar

    2008-01-01

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores treated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcome the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better thermal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor

  11. Evaluation of the light weight Juggling system

    Directory of Open Access Journals (Sweden)

    Erev-Yehene Vered

    2011-12-01

    Full Text Available This paper presents the training of juggling skills, a highly complex problem of coordination, under tight time and space constraints. This training is achieved with a simple training platform, a light weight juggling platform (LWJ, and is compared to training with real balls. The principle directing the design of the platform is to obtain a simple tool. The simplification, in comparison to real world juggling, is based on the identification of invariant properties in the spatiotemporal coordination of intermediate and expert jugglers. Two classes training solutions were added to the LWJ: An audio-tactile pacing or augmented multimodal environment, and the manipulation of cognitive components of the juggling skills. The transfer to juggling with real balls was evaluated in four different experiments.

  12. Towards the Security Evaluation of Biometric Authentication Systems

    OpenAIRE

    El-Abed , Mohamad; Giot , Romain; Hemery , Baptiste; Rosenberger , Christophe; Schwartzmann , Jean-Jacques

    2011-01-01

    International audience; Despite the obvious advantages of biometric authentication systems over traditional security ones (based on tokens or passwords), they are vulnerable to attacks which may considerably decrease their security. In order to contribute in resolving such problematic, we propose a modality-independent evaluation methodology for the security evaluation of biometric systems. It is based on the use of a database of common threats and vulnerabilities of biometric systems, and th...

  13. Operation of inspection data acquisition and evaluation system

    International Nuclear Information System (INIS)

    Takahashi, Yoichi; Harada, Hiroshi; Watanabe, Masayuki; Sakaguchi, Makoto; Ishikawa, Masayuki

    2016-01-01

    Rokkasho Reprocessing Plant (RRP) is a large scale plant to treat a huge amount of Plutonium significant for safeguards. The LArge SCAle Reprocessing plant safeguards (LASCAR) Forum recommended an effective utilization of unattended verification systems and automated data acquisition system etc. Based on LASCAR recommendation, Nuclear Material Control Center (NMCC) has developed the inspection data acquisition system as the automated data acquisition system from the unattended verification systems (including non-destructive assay equipment, solution monitoring system and surveillance camera). The data gathered from the unattended verification system are provided to the inspection data evaluation system for the State and the IAEA. In this development, redundancy concepts for data transfer line, in order to prevent inspection data missing, were introduced, and the timely confirmation of solution behaver such as material flows and inventories by the solution monitoring can be achieved. Furthermore, for purpose of efficiency of evaluation of inspection activity for the State, NMCC has developed the inspection data evaluation system which operates automated partition of inspection data coming from each verification equipment. Additionally, the inspection data system evaluation can manage the inspection activities and their efforts. These development and operation have been funded by JSGO (Japan Safeguards Office). This paper describes development history and operation of the inspection data acquisition and evaluation system. (author)

  14. INTERNATIONAL LOGISTICS SYSTEMS DESIGN AND EFFECTIVENESS EVALUATION

    Directory of Open Access Journals (Sweden)

    N. V. Khalipova

    2015-08-01

    Full Text Available Purpose. In the paper the question of the development of a methodological approach to the determination of logistics systems’ performance and grounding of the most effective goods’ delivery schemes, based on the theory of functions and sets of multiple objects, vector optimization approaches and discrete maximum principle for multi-stage processes (phase method is considered. Methodology. To achieve the goals of the research, the model of logistic system represented by multiple object that defined by the structure and content. The object is represented by hybrid superposition, composed of sets, multi-sets, ordered sets (lists and inhomogeneous sets (sequences, corteges, which at each stage of cargo delivery present sets of technological operations of their processing, choices and decisions algorithms. Multiple structure of objects is constructive three, consisting of the carrier, signatures and axiomatic. To determine the effective scheme of delivery, applied discrete maximum principle using vector optimization criterion. Findings. In this article, logistics system of delivery is presented in the form of a multi-stage (phase of the process. Each stage reviews a plurality of discrete activities sets, which includes the possible technology cycles of operations in goods handling. At each stage of a multi-phase delivery process from the supplier to the consumer, these sets are different. Considered a model example solving the problem of vector optimization options for delivery of goods by the road in the international logistics system for the five-step process. Optimization performed on the basis of three indicators. Originality. In this paper, the choice of the most effective way of delivery goods produced using the theory of functions and sets of multiple objects, using the discrete maximum principle for multi-stage processes, based on the vector optimization criterion. At each of its stages are formed a plurality of valid solutions as

  15. GIS in Evaluation: Utilizing the Power of Geographic Information Systems to Represent Evaluation Data

    Science.gov (United States)

    Azzam, Tarek; Robinson, David

    2013-01-01

    This article provides an introduction to geographic information systems (GIS) and how the technology can be used to enhance evaluation practice. As a tool, GIS enables evaluators to incorporate contextual features (such as accessibility of program sites or community health needs) into evaluation designs and highlights the interactions between…

  16. An Evaluation System for Checking the Status of I and C Systems in Nuclear Power Plants

    International Nuclear Information System (INIS)

    JinWoo, Hyun; Hak-Yeong, Chung; ChanHo, Sung

    2006-01-01

    I and C upgrade has been hot issue around the world as progresses of degradation, aging and obsolescence have been getting worse with the continual I and C system operation, it is very difficult to develop I and C evaluation system for the real application to nuclear power plants due to complexity or reliability aspects of the methodology. Thus, to improve these problems related to evaluation and application of I and C systems, we have been developing an evaluation system which embarks an objective evaluation methodology and works on internet for convenience. This Evaluation system has been established based on the evaluation factors including system importance, performance, maintenance, aging, economic efficiency and the continuance of equipment supply, and each evaluation factor has some questionnaires which are composed of questions requiring quantitative and qualitative answers. The applied evaluation algorithm consists of scoring process among evaluation factors and weighting factor allocation process. The Evaluation system has a structure based on web environment. With this system, staffs from plant sites can directly conduct the evaluation of each I and C system status of the plant, survey of results, survey of upgrade information, and upgrade/maintenance plan. Also head office utilizes this system for the survey of the evaluation results, upgrade or maintenance plan of each site and especially acquires some useful information for making finance plans. (authors)

  17. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Technical Evaluation Report 30: Vendor-Assisted Evaluation of a Learning Management System

    Directory of Open Access Journals (Sweden)

    Adrienne De Schutter

    2004-04-01

    Full Text Available A product evaluation was conducted of Desire2Learn, an online learning management system gaining popularity in educational institutions. Since an online trial version of the software was not available for evaluation, an inspection meeting with the vendor was arranged. This provided the evaluation team with an opportunity to examine the precautions necessary for ensuring the objectivity of a product evaluation based on vendor-supplied information. The report outlines the team’s use of evaluator-driven enquiry and a triangulated approach to information checking. The Desire2Learn product is assessed as a flexible and useful addition to the range of learning management system options.

  19. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  20. Support for system connectivity –Learning from evaluating an evaluation

    DEFF Research Database (Denmark)

    Christensen, Jesper Lindgaard

    been sparse on investigat-ing effects of these as well as on the broader criteria to evaluate the innovation networks and functioning of the system. This paper discusses what are such criteria for evaluating innovation policies that rely on enhanc-ing system connectivity and repair system failures......Innovation is said to be dependent upon collaboration and networks. The innovation system thinking empha-sizes networks but also their supporting informal institutions, learning processes, and the relations between actors in the system. Despite the importance of networks, evaluation studies have......? By way of illustration, and as a mean to be specific on these criteria, the paper discusses the possible rationale for governments to support business angel networks (BAN) and what criteria to apply when evaluating such networks. It is found that applying traditional evaluation criteria for assessing...

  1. System evaluations by means of reliability analyses

    International Nuclear Information System (INIS)

    Breiling, G.

    1976-01-01

    The objective of this study is to show which analysis requirements are associated with the claim that a reliability analysis, as practised at present, can provide a quantitative risk assessment in absolute terms. The question arises of whether this claim can be substantiated without direct access to the specialist technical departments of a manufacturer and to the multifarious detail information available in these departments. The individual problems arising in the course of such an analysis are discussed on the example of a reliability analysis of a core flooding system. The questions discussed relate to analysis organisation, sequence analysis, fault-tree analysis, and the treatment of operational processes superimposed on the failure and repair processes. (orig.) [de

  2. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Background: Rivers State has been reported to have the highest HIV prevalence of all the thirty-six states in Nigeria. HIV surveillance system generates information for timely and appropriate public health action. Evaluation of the surveillance system is vital in ensuring that the purpose of the surveillance system is being met.

  3. Managing data from remeasured plots: An evaluation of existing systems

    Science.gov (United States)

    John C. Byrne; Michael D. Sweet

    1992-01-01

    Proper management of the valuable data from remeasured (or permanent) forest growth plots with data base management systems (DBMS) can greatly add to their utility. Twelve desired features for such a system (activities that facilitate the storage, accuracy, and use of the data for analysis) are described and used to evaluate the 36 systems found by a survey conducted...

  4. Online evaluation of point-of-interest recommendation systems

    NARCIS (Netherlands)

    Dean-Hall, A.; Clarke, C.L.A.; Kamps, J.; Kiseleva, J.

    2015-01-01

    In this work we describe a system to evaluate multiple point- of-interest recommendation systems. In this system each recommendation service will be exposed online and crowd-sourced assessors will interact with merged results from multiple services, which are responding to suggestion requests live,

  5. Evaluating the Security Risks of System Using Hidden Markov Models

    African Journals Online (AJOL)

    System security assessment tools are either restricted to manual risk evaluation methodologies that are not appropriate for real-time application or used to determine the impact of certain events on the security status of networked systems. In this paper, we determine the strength of computer systems from the perspective of ...

  6. Evaluation Of Vibration-Monitoring Gear-Diagnostic System

    Science.gov (United States)

    Townsend, Dennis P.; Zakrajsek, James J.

    1995-01-01

    Report describes experimental evaluation of commercial electronic system designed to monitor vibration signal from accelerometer on gear-box to detect vibrations indicative of damage to gears. System includes signal-conditioning subsystem and personal computer in which analog-to-digital converter installed. Results show system fairly effective in detecting surface fatigue pits on spur-gear teeth.

  7. The City Intelligence Quotient (City IQ Evaluation System: Conception and Evaluation

    Directory of Open Access Journals (Sweden)

    Zhiqiang Wu

    2016-06-01

    Full Text Available After a systematic review of 38 current intelligent city evaluation systems (ICESs from around the world, this research analyzes the secondary and tertiary indicators of these 38 ICESs from the perspectives of scale structuring, approaches and indicator selection, and determines their common base. From this base, the fundamentals of the City Intelligence Quotient (City IQ Evaluation System are developed and five dimensions are selected after a clustering analysis. The basic version, City IQ Evaluation System 1.0, involves 275 experts from 14 high-end research institutions, which include the Chinese Academy of Engineering, the National Academy of Science and Engineering (Germany, the Royal Swedish Academy of Engineering Sciences, the Planning Management Center of the Ministry of Housing and Urban-Rural Development of China, and the Development Research Center of the State Council of China. City IQ Evaluation System 2.0 is further developed, with improvements in its universality, openness, and dynamic adjustment capability. After employing deviation evaluation methods in the IQ assessment, City IQ Evaluation System 3.0 was conceived. The research team has conducted a repeated assessment of 41 intelligent cities around the world using City IQ Evaluation System 3.0. The results have proved that the City IQ Evaluation System, developed on the basis of intelligent life, features more rational indicators selected from data sources that can offer better universality, openness, and dynamics, and is more sensitive and precise.

  8. Small Bore Piping Socket Weld Evaluation System

    International Nuclear Information System (INIS)

    Lee, Dong Min; Cho, Hong Seok; Choi, Sang Hoon; Cho, Ki Hyun; Lee, Jang Wook

    2009-01-01

    Kori unit 3 had stopped operation due to leakage at Steam Generator drain line socket weld on June 6, 2008. The Cause of socket weld damage was known as a fatigue crack. According to this case, all socket welds located in RCS pressure boundary are carrying out Radiographic Testing. But to inspect socket welds by RT has some problems. The result of EPRI study showed that RT has limitation to find flaws at socket welds.The orientation of flaws has big influence on RT inspection capability and there is not enough space at socket welds for RT, dose problems as well. Although the gap between coupling and pipe at socket welds must follow up code, surface inspection can't inspect the gap. If there is absence of the gap, socket welds are damaged during operation. The gap should be identified by RT but the distance of gap can't be measured. As this paper, the ultrasonic inspection system was introduced to figure out indication and gap in the socket welds

  9. Safety evaluation of BWR off-gas treatment systems

    International Nuclear Information System (INIS)

    Schultz, R.J.; Schmitt, R.C.

    1975-01-01

    Some of the results of a safety evaluation performed on current generic types of BWR off-gas treatment systems including cooled and ambient temperature adsorber beds and cryogenics are presented. The evaluation covered the four generic types of off-gas systems and the systems of five major vendors. This study was part of original work performed under AEC contract for the Directorate of Regulatory Standards. The analysis techniques employed for the safety evaluation of these systems include: Fault Tree Analysis; FMECA (Failure Mode Effects and Criticality Analysis); general system comparisons, contaminant, system control, and design adequacy evaluations; and resultant Off-Site Dose Calculations. The salient areas presented are some of the potential problem areas, the approach that industry has taken to mitigate or design against potential upset conditions, and areas where possible deficiencies still exist. Potential problem areas discussed include hydrogen detonation, hydrogen release to equipment areas, operator/automatic control interface, and needed engineering evaluation to insure safe system operation. Of the systems reviewed, most were in the category of advanced or improved over that commonly in use today, and a conclusion from the study was that these systems offer excellent potential for noble gas control for BWR power plants where more stringent controls may be specified -- now or in the future. (U.S.)

  10. Design and evaluation of an integrated safeguards system: principles

    International Nuclear Information System (INIS)

    Markin, J.T.; Coulter, C.A.; Gutmacher, R.G.; Whitty, W.J.

    1984-07-01

    An integrated safeguards system is defined as a collection of safeguards activities in which system components are coordinated to meet safeguards objectives efficiently within constraints imposed by safeguards resources, facility operations, potential adversaries, and regulatory requirements. This paper describes principles for designing and evaluating an integrated safeguards system that consists of four parts: (1) a problem definition phase that specifies resources and constraints composing the problem boundary values; (2) a system analysis/synthesis phase that describes how to select and integrate safeguards activities for efficient attainment of system objectives; (3) a system evaluation/optimization phase that defines measures of safeguards performance and develops methods for evaluating them; and (4) a decision-making phase that develops principles for selecting admissible designs and preference-ordering designs. 6 references, 4 figures, 5 tables

  11. Design and evaluation of an integrated safeguards system: principles

    International Nuclear Information System (INIS)

    Markin, J.T.; Coulter, C.A.; Gutmacher, R.G.; Whitty, W.J.

    1984-01-01

    An integrated safeguards system is defined as a collection of safeguards activities in which system components are coordinated to meet safeguards objectives efficiently within constraints imposed by safeguards resources, facility operations, potential adversaries, and regulatory requirements. This paper describes principles for designing and evaluating an integrated safeguards system that consists of four parts: a problem definition phase that specifies resources and constraints composing the problem boundary values, a system analysis/synthesis phase that describes how to select and integrate safeguards activities for efficient attainment of system objectives, a system evaluation/optimization phase that defines measures of safeguards performance and develops methods for evaluating them, and a decision-making phase that develops principles for selecting admissible designs and preference-ordering designs

  12. Expert systems for space power supply: design, analysis, and evaluation

    International Nuclear Information System (INIS)

    Cooper, R.S.; Thomson, M.K.; Hoshor, A.

    1987-01-01

    The authors evaluated the feasibility of applying expert systems to the conceptual design, analysis, and evaluation of space power supplies in particular, and complex systems in general. To do this, they analyzed the space power supply design process and in associated knowledge base, and characterized them in a form suitable for computer emulation of a human expert. The existing expert system tools and the results achieved with them were evaluated to assess their applicability to power system design. They applied some new concepts for combining program architectures (modular expert systems and algorithms) with information about the domain to create a deep system for handling the complex design problem. They authors developed, programmed and tested NOVICE, a code to solve a simplified version of a scoping study of a wide variety of power supply types for a broad range of missions, as a concrete feasibility demonstration

  13. The JAERI code system for evaluation of BWR ECCS performance

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Akimoto, Masayuki; Asahi, Yoshiro; Abe, Kiyoharu; Muramatsu, Ken; Araya, Fumimasa; Sato, Kazuo

    1982-12-01

    Development of respective computer code system of BWR and PWR for evaluation of ECCS has been conducted since 1973 considering the differences of the reactor cooling system, core structure and ECCS. The first version of the BWR code system, of which developmental work started earlier than that of the PWR, has been completed. The BWR code system is designed to provide computational tools to analyze all phases of LOCAs and to evaluate the performance of the ECCS including an ''Evaluation Model (EM)'' feature in compliance with the requirements of the current Japanese Evaluation Guideline of ECCS. The BWR code system could be used for licensing purpose, i.e. for ECCS performance evaluation or audit calculations to cross-examine the methods and results of applicants or vendors. The BWR code system presented in this report comprises several computer codes, each of which analyzes a particular phase of a LOCA or a system blowdown depending on a range of LOCAs, i.e. large and small breaks in a variety of locations in the reactor system. The system includes ALARM-B1, HYDY-B1 and THYDE-B1 for analysis of the system blowdown for various break sizes, THYDE-B-REFLOOD for analysis of the reflood phase and SCORCH-B2 for the calculation of the fuel assembl hot plane temperature. When the multiple codes are used to analyze a broad range of LOCA as stated above, it is very important to evaluate the adequacy and consistency between the codes used to cover an entire break spectrum. The system consistency together with the system performance are discussed for a large commercial BWR. (author)

  14. Evaluation of real-time operating system for small-scale embedded systems

    International Nuclear Information System (INIS)

    Dayang Norhayati Abang Jawawi; Rosbi Mamat

    1999-01-01

    In this paper, the performance of some real-time operating systems for small-scale embedded systems are evaluated based on some criteria. The evaluation is performed qualitatively and quantitatively. The evaluation results based on a case study on an engineering application will be presented. (author)

  15. Thermodynamic evaluation of the Cu-Mg-Zr system

    International Nuclear Information System (INIS)

    Haemaelaeinen, M.; Zeng, K.

    1999-01-01

    The thermodynamic evaluation of the Cu-Mg-Zr system is presented in this paper. A literature survey was carried out first based on the most recent literature, which was scanned from the THERMET literature database. The evaluation of the thermodynamic parameters was carried out using Thermo-Calc (version H) software. The evaluation of the Cu-Mg-Zr system was carried out using the most recent experimental data from the literature and a set of DTA measurements. DTA measurements were done using alumina (Al 2 O 3 ) crucibles under helium atmosphere with the niobium (Nb) reference crucible. The evaluated Cu-Mg-Zr phase diagram fitted well with experimental data with the liquidus data in a limited range of composition. There were two miscibility gaps observe in the system. New τ phase was detected using the X-ray and microscopic analysis and the data was used in this evaluation. (orig.)

  16. Virtualization of System of Systems Test and Evaluation

    Science.gov (United States)

    2012-06-04

    computers and is the primary enabler for virtualization. 2. Virtualization System Elements Parmalee, Peterson , Tillman, & Hatfield (1972) outlined the...The work of Abu-Taieh and El Sheikh, based on the work of Balci (1994, 1995), and Balci et al. ( 1996 ), seeks to organize types of tests and to...and testing. In A. Dasso & A. Funes (Eds.), Verification, validation, and testing in software engineering (pp. 155–184). Hershey , PA: Idea Group

  17. Evaluation of Hindi to Punjabi Machine Translation System

    OpenAIRE

    Goyal, Vishal; Lehal, Gurpreet Singh

    2009-01-01

    Machine Translation in India is relatively young. The earliest efforts date from the late 80s and early 90s. The success of every system is judged from its evaluation experimental results. Number of machine translation systems has been started for development but to the best of author knowledge, no high quality system has been completed which can be used in real applications. Recently, Punjabi University, Patiala, India has developed Punjabi to Hindi Machine translation system with high accur...

  18. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.; Tsui, B.

    1981-01-01

    A general computer code to simulate the imaging properties of existing and hypothetical imaging systems viewing realistic source distributions within non-uniform media. Such a code allows comparative evaluations of existing and hypothetical systems, and optimization of critical parameters of system design by maximizing the signal-to-noise ratio. To be most useful, such a code allows simulation of conventional scintillation scanners and cameras as well as single-photon and position tomographic systems

  19. Quantitative evaluation of physical protection system in nuclear power plant

    International Nuclear Information System (INIS)

    Sun Yahua; Li Bin; Li Shiju

    2009-01-01

    Based on the prompt detection analysis, this paper introduced one analysis model of intrusion path in nuclear power plant by means of morphology analysis and developed the evaluation software for path model analysis of physical protection system. Quantitative analysis on three elements (detection, delay, and response) of physical protection system was presented with an imaginary intrusion event example in Mac Arthur nuclear center. The results indicated that the path prompt detection analysis worked effectively to find the weak point of the physical protection system in NPP, and meantime we can also get the high cost-effectiveness improved measures. It is an effective approach to evaluate the overall performance of the system. (authors)

  20. Exploration of nuclear power enterprise 'STAR' management performance evaluation system

    International Nuclear Information System (INIS)

    Wang Sen

    2005-01-01

    From the angle of nuclear power enterprise safety culture, this essay breaks the connotations of the safety culture down to nine aspects (target management, safety management, quality management, housekeeping, cost control, authorization management, teamwork, communication and continued improvement), with each aspect divided into five levels of star class according to its own characteristics. A comparison is made between the actualities of the enterprise and star management performance evaluation system to find out the gap and identify ways of continued improvement to elevate the enterprise management level, thereby developing a standard system of conducting qualitative and quantitative evaluation to the management process. Apart from its evaluation function, this system provides a guideline on the work orientation, method, and steps to elevate work level and capability for the managers performing specific management actions. It is also a system of measuring and evaluating the executive force of the company's management and its employees. (author)

  1. Multi-criteria evaluation for CHP system options

    International Nuclear Information System (INIS)

    Pilavachi, P.A.; Roumpeas, C.P.; Minett, S.; Afgan, N.H.

    2006-01-01

    Several Combined Heat and Power (CHP) system options have been considered for evaluation with respect to the end-user requirements. These included Internal Combustion Engines (Otto and Diesel), Gas Turbines, Steam Turbines and Combined Cycles covering a wide range of electrical output. Data have been obtained from literature and the CHP systems have been evaluated using different criteria such as overall efficiency, investment cost, fuel cost, electricity cost, heat cost, CO 2 production and footprint. A multi-criteria method is used with an agglomeration function based on the statistical evaluation of weight factors. The technical, economic and social aspects of each system have been evaluated in an integrated manner and the results have been compared by means of the Sustainability Index. Based on the above criteria and depending on the user requirements, the best CHP system options have been established

  2. Energy and environmental evaluation of tri-generation energy systems

    International Nuclear Information System (INIS)

    Chicco, G.; Mancarella, P.

    2008-01-01

    Tri generation facilities manufactured with various technologies represent an important alternative solution for the development more efficient energy systems and low environmental impact. Are described the issues related to modelling and energy and environmental evaluation [it

  3. Evaluation of Communication Alternatives for Intelligent Transportation Systems

    Science.gov (United States)

    2010-08-31

    The primary focus of this study involved developing a process for the evaluation of wireless technologies : for intelligent transportation systems, and for conducting experiments of potential wireless technologies : and topologies. Two wireless techn...

  4. Credit Risk Evaluation System For Nigerian Banks Using Artificial Ne

    African Journals Online (AJOL)

    MANKABS

    CREDIT RISK EVALUATION SYSTEM: AN ARTIFICIAL NEURAL NETWORK APPROACH of their own experiential .... limitations concern the high computational ... Number of existing credits at this bank. 7. Personal status and sex. 14. Job. 17.

  5. Evaluation of New Fluid Mud Survey System at Field Sites

    National Research Council Canada - National Science Library

    Engler

    1992-01-01

    This technical note presents an intermediate evaluation of a fluid mud survey system with respect to operability, practicability, and repeatability based on field tests conducted at Calcasieu River, Louisiana...

  6. Signature Evaluation for Thermal Infrared Countermine and IED Detection Systems

    National Research Council Canada - National Science Library

    Peters, John F; Howington, Stacy E; Ballard, Jr., Jerry; Lynch, Larry N

    2007-01-01

    .... These simulations provide information ranging from simple temperature contrasts to high-resolution images comparable to actual sensor images that can be used to evaluate or train automatic target recognition (ATR) systems...

  7. the evaluation of a discrete automatic analysis system

    African Journals Online (AJOL)

    1971-05-29

    May 29, 1971 ... analytical systems have appeared on the market (for a general review, see ... The testing and evaluation of new scientific equipment has in recent years .... automation into the clinical chemistry laboratory, it is necessary to ...

  8. An evaluation of professional quality measurement systems for the ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... An evaluation of professional quality measurement systems for the automotive industry ... The ultimate goal of this study is to get comparable quantitative information about ...

  9. Evaluation of Ethiopian Tax Administration System: emphasis on ...

    African Journals Online (AJOL)

    , assessed the culture of voluntary compliance, looked at how taxpayers perceive service delivery by the revenue authority, and evaluated the fairness perception of the Ethiopian tax system. Data for the study were gathered primarily through ...

  10. Holistic Evaluation of Lightweight Operating Systems using the PERCU Method

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, William T.C.; He, Yun (Helen); Carter, Jonathan; Glenski, Joseph; Rippe, Lynn; Cardo, Nicholas

    2008-05-01

    The scale of Leadership Class Systems presents unique challenges to the features and performance of operating system services. This paper reports results of comprehensive evaluations of two Light Weight Operating Systems (LWOS), Cray's Catamount Virtual Node (CVN) and Linux Environment (CLE) operating systems, on the exact same large-scale hardware. The evaluation was carried out over a 5-month period on NERSC's 19,480 core Cray XT-4, Franklin, using a comprehensive evaluation method that spans Performance, Effectiveness, Reliability, Consistency and Usability criteria for all major subsystems and features. The paper presents the results of the comparison between CVN and CLE, evaluates their relative strengths, and reports observations regarding the world's largest Cray XT-4 as well.

  11. Promoting evaluation capacity building in a complex adaptive system.

    Science.gov (United States)

    Lawrenz, Frances; Kollmann, Elizabeth Kunz; King, Jean A; Bequette, Marjorie; Pattison, Scott; Nelson, Amy Grack; Cohn, Sarah; Cardiel, Christopher L B; Iacovelli, Stephanie; Eliou, Gayra Ostgaard; Goss, Juli; Causey, Lauren; Sinkey, Anne; Beyer, Marta; Francisco, Melanie

    2018-04-10

    This study provides results from an NSF funded, four year, case study about evaluation capacity building in a complex adaptive system, the Nanoscale Informal Science Education Network (NISE Net). The results of the Complex Adaptive Systems as a Model for Network Evaluations (CASNET) project indicate that complex adaptive system concepts help to explain evaluation capacity building in a network. The NISE Network was found to be a complex learning system that was supportive of evaluation capacity building through feedback loops that provided for information sharing and interaction. Participants in the system had different levels of and sources of evaluation knowledge. To be successful at building capacity, the system needed to have a balance between both centralized and decentralized control, coherence, redundancy, and diversity. Embeddedness of individuals within the system also provided support and moved the capacity of the system forward. Finally, success depended on attention being paid to the control of resources. Implications of these findings are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Ionizing radiation detection meter systems usability evaluation. Technical memorandum

    International Nuclear Information System (INIS)

    Severs, Y.; Hughes, R.; Tack, D.; Bossi, L.L.M.

    2002-12-01

    In support of the Canadian Forces Nuclear Detection, Identification and Dosimetry project a usability trial of three Ionizing Radiation Detection Meter Systems (IRDMS) was conducted 18-22 June 2001 at Connaught Ranges. The systems evaluated: System 1: ANPDR 77 Operational System with PDR 77 Alpha/Beta probes and GPS (Global Positioning System) Training System; System 2: ADM 300C Operational System with ABP 100 Alpha/Beta probes and GPS Training System, and System 3: RAM R200 Operational System with PA 100M and RG12 Alpha/Beta probes and GPS Training System. Twelve military personnel (Private to Captain) determined compliance with the bid evaluation criteria. The counter-balanced study, based on a Latin square design, was divided into two assessment phases, an operational phase and a training system phase, which rotated three groups (of four participants each) concurrently through each IRDMS. Groups were trained in set-up, maintenance and operation of each bid IRDMS prior to evaluation. The operational evaluation consisted of a test/maintenance stand, an indoor/outdoor operational stand, and an indoor,/outdoor training system stand. Participants rated the utility and usability of each system, by measuring case of use/maintenance under a range of relevant operational and clothing conditions, compatibility with soldier tasks, compatibility with clothing, compatibility with equipment and operational environments, and case of learning (including an assessment of initial and refresher training implications). A 7-point Likert-like acceptability rating scale, which covered a range from completely unacceptable (1) to completely acceptable (7), was used to evaluate the measures. The combined weighted mean scores were 584.3 for System 1 (70 o /b), 682.0 for System 2 (81 %) and 756.9 for System 3 (90%) out of a total possible score of 840. Participants reported mean scores for System 1 between barely unacceptable and borderline for both indoor and outdoor operations. System 2

  13. Material control test and evaluation system at the ICPP

    International Nuclear Information System (INIS)

    Johnson, C.E.

    1979-01-01

    The US DOE is evaluating process monitoring as part of a total nuclear material safeguards system. A monitoring system is being installed at the Idaho Chemical Processing Plant to test and evaluate material control and surveillance concepts in an operating nuclear fuel reprocessing plant. Process monitoring for nuclear material control complements conventional safeguards accountability and physical protection to assure adherence to approved safeguards procedures and verify containment of nuclear materials within the processing plant

  14. A Tissue Retrieval and Postharvest Processing Regimen for Rodent Reproductive Tissues Compatible with Long-Term Storage on the International Space Station and Postflight Biospecimen Sharing Program

    Directory of Open Access Journals (Sweden)

    Vijayalaxmi Gupta

    2015-01-01

    Full Text Available Collection and processing of tissues to preserve space flight effects from animals after return to Earth is challenging. Specimens must be harvested with minimal time after landing to minimize postflight readaptation alterations in protein expression/translation, posttranslational modifications, and expression, as well as changes in gene expression and tissue histological degradation after euthanasia. We report the development of a widely applicable strategy for determining the window of optimal species-specific and tissue-specific posteuthanasia harvest that can be utilized to integrate into multi-investigator Biospecimen Sharing Programs. We also determined methods for ISS-compatible long-term tissue storage (10 months at −80°C that yield recovery of high quality mRNA and protein for western analysis after sample return. Our focus was reproductive tissues. The time following euthanasia where tissues could be collected and histological integrity was maintained varied with tissue and species ranging between 1 and 3 hours. RNA quality was preserved in key reproductive tissues fixed in RNAlater up to 40 min after euthanasia. Postfixation processing was also standardized for safe shipment back to our laboratory. Our strategy can be adapted for other tissues under NASA’s Biospecimen Sharing Program or similar multi-investigator tissue sharing opportunities.

  15. Improving Teacher Evaluation Systems: Making the Most of Multiple Measures

    Science.gov (United States)

    Grissom, Jason A., Ed.; Youngs, Peter, Ed.

    2015-01-01

    This is the first book to gather and address what we have learned about the impacts and challenges of data-intensive teacher evaluation systems--a defining characteristic of the current education policy landscape. Expert researchers and practitioners speak to what we know (and what remains to be known) about evaluation measures themselves, the…

  16. A qualitative evaluation approach for energy system modelling frameworks

    DEFF Research Database (Denmark)

    Wiese, Frauke; Hilpert, Simon; Kaldemeyer, Cord

    2018-01-01

    properties define how useful it is in regard to the existing challenges. For energy system models, evaluation methods exist, but we argue that many decisions upon properties are rather made on the model generator or framework level. Thus, this paper presents a qualitative approach to evaluate frameworks...

  17. A monitoring and evaluation system for South African higher education

    African Journals Online (AJOL)

    ... that for monitoring and evaluation to have a function beyond mere accountability and resource allocation they have to transcend the generation of baseline data and venture into the more complicated and contested terrain of explanation. For this to happen, monitoring and evaluation systems need to be deeply embedded ...

  18. INFORMATION SYSTEMS EVALUATION CRITERIA BASED ON ATTITUDES OF GRADUATE STUDENTS

    Directory of Open Access Journals (Sweden)

    DAŘENA, František

    2011-03-01

    Full Text Available Importance of information systems in supporting business activities and managerial decision making is growing. Decisions related to selecting a suitable information system, including the technological background, human resources, procedures and information belong to one of the most difficult and most responsible ones. As in the case of other types of investments, assets and resources invested into information system should return in a reasonable time. There has been a lot of work done in the research and application of IS evaluation techniques to different kinds of information systems. Such evaluations involve a wide variety of technical and technological considerations made by technical experts, on the other hand impacts on management of the organization or financial impacts can be addressed. The objective of the paper is to reveal the preferences of graduate students related to their information systems evaluation and to propose a general framework for such evaluations. During the experimental period two surveys were carried out within the information systems course – at the beginning when the students were completely uninformed and at the end when the students had the knowledge of individual aspects of information systems, their role within organizations and process of information systems evaluation. The former survey used a simple scoring method whereas the latter relied on formal usage of the Analytical Hierarchy Process. The results show the differences in opinions of the students between these two surveys. Presented criteria hierarchy as well as the importance of individual evaluation criteria can be used for demonstration of attitudes of graduate students of management study programs and as a general framework for information systems evaluation.

  19. Research status and evaluation system of heat source evaluation method for central heating

    Science.gov (United States)

    Sun, Yutong; Qi, Junfeng; Cao, Yi

    2018-02-01

    The central heating boiler room is a regional heat source heating center. It is also a kind of the urban environment pollution, it is an important section of building energy efficiency. This article through to the evaluation method of central heating boiler room and overviews of the researches during domestic and overseas, summarized the main influence factors affecting energy consumption of industrial boiler under the condition of stable operation. According to the principle of establishing evaluation index system. We can find that is great significance in energy saving and environmental protection for the content of the evaluation index system of the centralized heating system.

  20. Northeast Inspection Services, Inc. boresonic inspection system evaluation

    International Nuclear Information System (INIS)

    Nottingham, L.D.; Sabourin, P.F.; Presson, J.H.

    1993-04-01

    Turbine rotor reliability and remaining life assessment are continuing concerns to electric utilities. Over the years, boresonic inspection and evaluation have served as primary components in rotor remaining life assessment. Beginning with an evaluation of TREES by EPRI in 1982, a series of reports that document the detection and sizing capabilities of several boresonic systems have been made available. These studies should provide utilities with a better understanding of system performance and lead to improved reliability when predicting rotor remaining life. In 1990, the procedures followed for evaluating rotor boresonic performance capabilities were changed to transfer a greater portion of the data analysis function to the participating vendor. This change from previous policy was instituted so that the evaluation results would better reflect the ''final answer'' that a vendor would provide in a real rotor inspection and also to reduce the cost of an evaluation. Among the first vendors to participate in the new performance demonstration was Northeast Inspection Services, Inc. (NISI). The tests reported herein were conducted by NISI personnel under the guidelines of the new plan. Details of the new evaluation plan are also presented. Rotor bore blocks containing surface-connected fatigue cracks, embedded glass beads, and embedded radial-axial oriented disks were used in the evaluation. Data were collected during twenty-five independent passes through the blocks. The evaluation consisted of statistical characterization of the detection capabilities, flaw sizing and location accuracy, and repeatability of the inspection system. The results of the evaluation are included in this report

  1. Development of EDFSRS: evaluated data files storage and retrieval system

    International Nuclear Information System (INIS)

    Hasegawa, Akira

    1985-07-01

    EDFSRS: Evaluated Data Files Storage and Retrieval System has been developed, which is a complete service system for the evaluated nuclear data files compiled in the major three formats: ENDF/B, UKNDL and KEDAK. This system intends to give efficient loading and maintenance of evaluated nuclear data files to the data base administrators and efficient retrievals to their users not only with the easiness but with the best confidence. It can give users all of the information available in these major three formats. The system consists of more than fifteen independent programs and some 150 Mega byte data files and index files (data-base) of the loaded data. In addition it is designed to be operated in the on-line TSS (Time Sharing System) mode, so that users can get any information from their desk top terminals. This report is prepared as a reference manual of the EDFSRS. (author)

  2. [Development and clinical evaluation of an anesthesia information management system].

    Science.gov (United States)

    Feng, Jing-yi; Chen, Hua; Zhu, Sheng-mei

    2010-09-21

    To study the design, implementation and clinical evaluation of an anesthesia information management system. To record, process and store peri-operative patient data automatically, all kinds of bedside monitoring equipments are connected into the system based on information integrating technology; after a statistical analysis of those patient data by data mining technology, patient status can be evaluated automatically based on risk prediction standard and decision support system, and then anesthetist could perform reasonable and safe clinical processes; with clinical processes electronically recorded, standard record tables could be generated, and clinical workflow is optimized, as well. With the system, kinds of patient data could be collected, stored, analyzed and archived, kinds of anesthesia documents could be generated, and patient status could be evaluated to support clinic decision. The anesthesia information management system is useful for improving anesthesia quality, decreasing risk of patient and clinician, and aiding to provide clinical proof.

  3. Evaluation of an intelligent open learning system for engineering education

    Directory of Open Access Journals (Sweden)

    Maria Samarakou

    2016-09-01

    Full Text Available In computer-assisted education, the continuous monitoring and assessment of the learner is crucial for the delivery of personalized education to be effective. In this paper, we present a pilot application of the Student Diagnosis, Assistance, Evaluation System based on Artificial Intelligence (StuDiAsE, an open learning system for unattended student diagnosis, assistance and evaluation based on artificial intelligence. The system demonstrated in this paper has been designed with engineering students in mind and is capable of monitoring their comprehension, assessing their prior knowledge, building individual learner profiles, providing personalized assistance and, finally, evaluating a learner's performance both quantitatively and qualitatively by means of artificial intelligence techniques. The architecture and user interface of the system are being exhibited, the results and feedback received from a pilot application of the system within a theoretical engineering course are being demonstrated and the outcomes are being discussed.

  4. Evaluation and technologic improvement of an enhanced imaging system

    International Nuclear Information System (INIS)

    Henry, D.

    1990-08-01

    Feature-based systems that combine imaging and signal analysis capabilities may be useful for nondestructive evaluation (NDE) of plant components. This report describes the metallurgical evaluation conducted to verify the performance of a feature-based system to discriminate intergranular stress corrosion cracking (IGSCC) from benign geometrical reflectors. The ultrasonic examination results were also evaluated by examination personnel trained in intergranular stress corrosion cracking (IGSCC) detection techniques. The welds were examined prior to their removal from the recirculation and Residual-Heat-Removal (RHR) piping systems of the Peach Bottom Atomic Power Plant, as described in the Phase 2 Interim Report issued in June 1989. In this phase of the program, a metallurgical evaluation was performed on piping system welds that were examined ultrasonically using a feature-based system for analysis. The feature-based system correctly identified crack, but incorrectly identified other features, e.g., root geometry and metallurgical interfaces, as cracks. While the results of the analysis by the feature-based system were not identical to the results of analysis by trained personnel, the overall performance of the feature-based system was comparable to that of the trained personnel. Based on the results of this program, the feature-based system may be useful as a supplementary method of identifying IGSCC indications. When used in conjunction with existing methods and techniques, it could improve the accuracy of IGSCC identification

  5. A Top-N Recommender System Evaluation Protocol Inspired by Deployed Systems

    NARCIS (Netherlands)

    A. Said (Alan); A. Bellogín Kouki (Alejandro); A.P. de Vries (Arjen)

    2013-01-01

    htmlabstractThe evaluation of recommender systems is crucial for their development. In today's recommendation landscape there are many standardized recommendation algorithms and approaches, however, there exists no standardized method for experimental setup of evaluation -- not even for widely used

  6. Evaluating Management Information Systems, A Protocol for Automated Peer Review Systems

    OpenAIRE

    Black, Gordon C.

    1980-01-01

    This paper discusses key issues in evaluating an automated Peer Review System. Included are the conceptual base, design, steps in planning structural components, operation parameters, criteria, costs and a detailed outline or protocol for use in the evaluation.

  7. Design and evaluation of physical protection systems of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model.

  8. Evaluating Models of Human Performance: Safety-Critical Systems Applications

    Science.gov (United States)

    Feary, Michael S.

    2012-01-01

    This presentation is part of panel discussion on Evaluating Models of Human Performance. The purpose of this panel is to discuss the increasing use of models in the world today and specifically focus on how to describe and evaluate models of human performance. My presentation will focus on discussions of generating distributions of performance, and the evaluation of different strategies for humans performing tasks with mixed initiative (Human-Automation) systems. I will also discuss issues with how to provide Human Performance modeling data to support decisions on acceptability and tradeoffs in the design of safety critical systems. I will conclude with challenges for the future.

  9. Using modeling to develop and evaluate a corrective action system

    International Nuclear Information System (INIS)

    Rodgers, L.

    1995-01-01

    At a former trucking facility in EPA Region 4, a corrective action system was installed to remediate groundwater and soil contaminated with gasoline and fuel oil products released from several underground storage tanks (USTs). Groundwater modeling was used to develop the corrective action plan and later used with soil vapor modeling to evaluate the systems effectiveness. Groundwater modeling was used to determine the effects of a groundwater recovery system on the water table at the site. Information gathered during the assessment phase was used to develop a three dimensional depiction of the subsurface at the site. Different groundwater recovery schemes were then modeled to determine the most effective method for recovering contaminated groundwater. Based on the modeling and calculations, a corrective action system combining soil vapor extraction (SVE) and groundwater recovery was designed. The system included seven recovery wells, to extract both soil vapor and groundwater, and a groundwater treatment system. Operation and maintenance of the system included monthly system sampling and inspections and quarterly groundwater sampling. After one year of operation the effectiveness of the system was evaluated. A subsurface soil gas model was used to evaluate the effects of the SVE system on the site contamination as well as its effects on the water table and groundwater recovery operations. Groundwater modeling was used in evaluating the effectiveness of the groundwater recovery system. Plume migration and capture were modeled to insure that the groundwater recovery system at the site was effectively capturing the contaminant plume. The two models were then combined to determine the effects of the two systems, acting together, on the remediation process

  10. Hospital employs TQM principles to rework its evaluation system.

    Science.gov (United States)

    Burda, D

    1992-02-24

    One Kansas hospital has taken the traditional employee evaluation process--with all its performance criteria, point systems and rankings--and turned it on its head. The new system employs total quality management principles and promotes personal development, education and teamwork. And everyone gets the same raise.

  11. 42 CFR 403.314 - Evaluation of State systems.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Evaluation of State systems. 403.314 Section 403.314 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PROVISIONS SPECIAL PROGRAMS AND PROJECTS Recognition of State Reimbursement Control Systems § 403...

  12. Evaluation of DICE, a terminological system for intensive care

    NARCIS (Netherlands)

    de Keizer, N. F.; Abu-Hanna, A.; Cornet, R.

    2000-01-01

    Evaluative research and the introduction of the Patient Data Management System to support care have increased the need for structured and standardized registration of diagnostic information in Dutch intensive cares (IC). To this end a terminological system to describe diagnoses is needed. A

  13. Regional Information System for Educators: Installation and Evaluation.

    Science.gov (United States)

    Kromer, Charles

    This document describes the installation and evaluation of the Regional Information System within the Michigan-Ohio Regional Educational Laboratory (MOREL). MOREL is an agency established to develop and test alternatives to current educational practice under Title IV of ESEA. The Regional Information System was established to provide referrals to…

  14. A scheme for evaluating a local queue warning system.

    NARCIS (Netherlands)

    Botma, H. & Oei, H.-L.

    2018-01-01

    This article outlines a method of evaluating a 'local queue warning system', in principle intended only to warn drivers of unexpected congestion at known discontinuities of the road geomctry (bottleneck) and give them advisory speed indications. A prerequisite for installing this system is therefore

  15. Requirements for the evaluation of computational speech segregation systems

    DEFF Research Database (Denmark)

    May, Tobias; Dau, Torsten

    2014-01-01

    Recent studies on computational speech segregation reported improved speech intelligibility in noise when estimating and applying an ideal binary mask with supervised learning algorithms. However, an important requirement for such systems in technical applications is their robustness to acoustic...... associated with perceptual attributes in speech segregation. The results could help establish a framework for a systematic evaluation of future segregation systems....

  16. Evaluation and testing methodology for evolving entertainment systems

    NARCIS (Netherlands)

    Jurgelionis, A.; Bellotti, F.; IJsselsteijn, W.A.; Kort, de Y.A.W.; Bernhaupt, R.; Tscheligi, M.

    2007-01-01

    This paper presents a testing and evaluation methodology for evolving pervasive gaming and multimedia systems. We introduce the Games@Large system, a complex gaming and multimedia architecture comprised of a multitude of elements: heterogeneous end user devices, wireless and wired network

  17. African Social Security Systems: An Ordinal Evaluation | Dixon ...

    African Journals Online (AJOL)

    The purpose of this paper is to rank the social security systems in 45 African countries using a comparative evaluation methodology that enables an assess ment to be ma(le of a country's statutory social security intention. The conclusion drawn is that the spread of African social security system design standards are ...

  18. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  19. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  20. Evaluation of intelligent transport systems impact on school transport safety

    Directory of Open Access Journals (Sweden)

    Jankowska-Karpa Dagmara

    2017-01-01

    Full Text Available The integrated system of safe transport of children to school using Intelligent Transport Systems was developed and implemented in four locations across Europe under the Safeway2School (SW2S project, funded by the EU. The SW2S system evaluation included speed measurements and an eye-tracking experiment carried out among drivers who used the school bus route, where selected elements of the system were tested. The subject of the evaluation were the following system elements: pedestrian safety system at the bus stop (Intelligent Bus Stop and tags for children, Driver Support System, applications for parents’ and students’ mobile phones, bus stop inventory tool and data server. A new sign designed for buses and bus stops to inform about child transportation/children waiting at the bus stop was added to the system. Training schemes for system users were also provided. The article presents evaluation results of the impact of selected elements of the SW2S system on school transport safety in Poland.

  1. Evaluation of computer-based ultrasonic inservice inspection systems

    International Nuclear Information System (INIS)

    Harris, R.V. Jr.; Angel, L.J.; Doctor, S.R.; Park, W.R.; Schuster, G.J.; Taylor, T.T.

    1994-03-01

    This report presents the principles, practices, terminology, and technology of computer-based ultrasonic testing for inservice inspection (UT/ISI) of nuclear power plants, with extensive use of drawings, diagrams, and LTT images. The presentation is technical but assumes limited specific knowledge of ultrasonics or computers. The report is divided into 9 sections covering conventional LTT, computer-based LTT, and evaluation methodology. Conventional LTT topics include coordinate axes, scanning, instrument operation, RF and video signals, and A-, B-, and C-scans. Computer-based topics include sampling, digitization, signal analysis, image presentation, SAFI, ultrasonic holography, transducer arrays, and data interpretation. An evaluation methodology for computer-based LTT/ISI systems is presented, including questions, detailed procedures, and test block designs. Brief evaluations of several computer-based LTT/ISI systems are given; supplementary volumes will provide detailed evaluations of selected systems

  2. Tested Tools You Can Use: Evaluating Earth System Science Courses

    Science.gov (United States)

    Lee, S. P.; Prakash, A.; Reider, D.; Baker, D.

    2006-12-01

    Earth System Science Education for the 21st Century (ESSE 21) has created a public access on-line evaluation resource available at http://esse21.usra.edu/evaltoolkit in collaboration with the ESSE 21 institutions, PIs, and evaluators. The purpose of the ESSE toolkit is to offer examples of how evaluation and assessment are/have been used in Earth System Science courses and programs. Our goal is to help instructors recognize different types of assessment and evaluation tools and uses that have proved useful in these courses and provide models for designing assessments in new courses. We have included actual examples of evaluations used by ESSE institution faculty in their own courses. This is not a comprehensive toolkit on educational evaluation and assessment, but it does provide several examples of evaluations that have been used successfully in Earth System Science courses and links to many good web resources on course evaluation. We have provided examples of assessments that are designed to collect information from students before, during and after courses. Some, presented in different formats, are designed to assess what students learn, others are designed to provide course instructors with information they can use to revise their courses. These assessments range from content tests to portfolios, from feedback forms to interviews, and from concept maps to attitude surveys.

  3. Study on index system of GPS interference effect evaluation

    Science.gov (United States)

    Zhang, Kun; Zeng, Fangling; Zhao, Yuan; Zeng, Ruiqi

    2018-05-01

    Satellite navigation interference effect evaluation is the key technology to break through the research of Navigation countermeasure. To evaluate accurately the interference degree and Anti-jamming ability of GPS receiver, this text based on the existing research results of Navigation interference effect evaluation, build the index system of GPS receiver effectiveness evaluation from four levels of signal acquisition, tracking, demodulation and positioning/timing and establish the model for each index. These indexes can accurately and quantitatively describe the interference effect at all levels.

  4. An Evaluation of Information Consistency in Grid Information Systems

    CERN Document Server

    Field, Laurence

    2017-01-01

    A Grid information system resolves queries that may need to consider all information sources (Grid services), which are widely distributed geographically, in order to enable efficient Grid functions that may utilise multiple cooperating services. Fundamentally this can be achieved by either moving the query to the data (query shipping) or moving the data to the query (data shipping). Existing Grid information system implementations have adopted one of the two approaches. This paper explores the two approaches in further detail by evaluating them to the best possible extent with respect to Grid information system benchmarking metrics. A Grid information system that follows the data shipping approach based on the replication of information that aims to improve the currency for highly-mutable information is presented. An implementation of this, based on an Enterprise Messaging System, is evaluated using the benchmarking method and the consequence of the results for the design of Grid information systems is discu...

  5. Experimental evaluation of human-system interaction on alarm design

    International Nuclear Information System (INIS)

    Huang, F.-H.; Lee, Y.-L.; Hwang, S.-L.; Yenn, T.-C.; Yu, Y.-C.; Hsu, C.-C.; Huang, H.-W.

    2007-01-01

    This study evaluates the practicability of automatic reset alarm system in Fourth Nuclear Power Plant (FNPP) of Taiwan. The features of auto-reset alarm system include dynamic prioritization of all alarm signals and fast system reset. Two experiments were conducted to evaluate the effect of automatic/manual reset on operation time, situational awareness (SA), task load index (TLX), and subjective ratings. All participants, including Experts and Novices, took part in the experiment on the alarm system simulator with Load Rejection procedure. The experimental results imply that the auto-reset alarm system may be applied in an advanced control room under Load Rejection procedure, because all participants' operation time were reduced as well as Novice's SA were raised up. Nevertheless, to ensure operating safety in FNPP, the effects of the auto-reset alarm system in other procedures/special situations still need to be tested in the near future

  6. Physical security system effectiveness evaluation, a status report

    International Nuclear Information System (INIS)

    Todd, J.L. Jr.; Nickell, W.C.

    1975-07-01

    A method to permit objective comparisons of physical security is under development and is expected to be useful in the optimization of system design and in cost benefit analysis. The procedure involves identifying the possible or potential characteristics of a postulated adversary, the countermeasures to deny or diminish adversary success, and the response capabilities of the defender. These, in conjunction with system definition information, are evaluated by the use of analytical models which provide a means of ranking systems against threats. This paper describes the status of this effort and includes an overview of the methodology with a brief description of various models being considered for use in effectiveness evaluation. (U.S.)

  7. System evaluation of improved thermal stability jet fuels

    Energy Technology Data Exchange (ETDEWEB)

    Binns, K.E.; Dieterle, G.L.; Williams, T. [Univ. of Dayton Research Institute, OH (United States)

    1995-05-01

    A single-pass, single-tube heat exchanger device called the Phoenix rig and a single-pass, dual-heat exchanger system called the Extended Duration Thermal Stability Test system are specific devices/systems developed for evaluating jet fuel thermal stability. They have been used extensively in the evaluation of various jet fuels and thermal stability additives. The test results have indicated that additives can substantially improve the thermal stability of conventional jet fuels. Relationships of oxygen consumption, residence time, bulk, and wetted wall temperatures on coking deposits that form in the heated tubes have also been investigated.

  8. Facility for the evaluation of space communications and related systems

    Science.gov (United States)

    Kerczewski, Robert J.; Svoboda, James S.; Kachmar, Brian A.

    1995-01-01

    NASA Lewis Research Center's Communications Projects Branch has developed a facility for the evaluation of space communications systems and related types of systems, called the Advanced Space Communications (ASC) Laboratory. The ASC Lab includes instrumentation, testbed hardware, and experiment control and monitor software for the evaluation of components, subsystems, systems, and networks. The ASC lab has capabilities to perform radiofrequency (RF), microwave, and millimeter-wave characterizations as well as measurements using low, medium, or high data rate digital signals. In addition to laboratory measurements, the ASC Lab also includes integrated satellite ground terminals allowing experimentation and measurements accessing operational satellites through real space links.

  9. Evaluation of components and systems of RSG-GAS and developing of maintenance evaluation software

    International Nuclear Information System (INIS)

    Pane, Jupiter-Sitorus; Kadarusmanto

    2003-01-01

    In order to enhance the evaluation of components and systems, inventarization of failure and repair data has been performed. The evaluation was done by calculating distribution function of failure, failure rate, MTTF, MTTR, and unavailability. The evaluation was comprehend in a code program of SYSCOM-RSG-GAS, that are able to performed statistical analysis, reliability parameters, and Fault Tree Analysis. This paper will describe some results of the program

  10. Test, measurement and evaluation with the mine boot test and evaluation system

    CSIR Research Space (South Africa)

    Ramaloko, PM

    2014-09-01

    Full Text Available Protective footwear that mitigates the shock transferred to the victim’s leg during an antipersonnel landmine blast need to be evaluated to verify their protection levels. The Mine Boot Test and Evaluation System which include a surrogate lower leg...

  11. Quality assurance and evaluation system in japanese higher education

    Directory of Open Access Journals (Sweden)

    Ana Mami Yamaguchi

    2016-03-01

    Full Text Available Abstract In this paper we aim to contribute to the debate over accountability and assessment of higher education (HE by introducing the Japanese system. We first discuss the circumstances and issues surrounding Japanese HE and then examine the historical development of the quality assurance and evaluation system. Since the 1990s, with the implementation of policies that focused on liberalization, deregulation and increased institutional autonomy, the role of the government has shifted from setting strict regulations and quality standards to organizing an evaluation system for assessing the learning outcomes and improving accountability of the HE institutions. Finally, we suggest how Japan may take hints from Brazil in organizing an evaluation system on a national level that can more efficiently support and assess HE institutions

  12. Multifunctional systems in vehicles:a usability evaluation

    OpenAIRE

    Rydström, Annie; Bengtsson, Peter; Grane, Camilla; Broström, Robert; Agardh, Johannes; Nilsson, Jennie

    2005-01-01

    Car Human-Machine Interaction (HMI) is becoming increasingly complex as the extension of functionality necessitates new interface concepts. Various multifunctional systems operated by haptic rotary switches, touch screen, and voice control have been developed. A usability study of multifunctional systems available on the market was carried out to evaluate and compare different manual interaction principles. The systems used in the study were the BMW iDrive and the Audi MMI, both operated by a...

  13. A Standardized Evaluation System for Decadal Climate Prediction

    Science.gov (United States)

    Kadow, C.; Cubasch, U.

    2012-12-01

    The evaluation of decadal prediction systems is a scientific challenge as well as a technical challenge in the climate research. The major project MiKlip (www.fona-miklip.de) for medium-term climate prediction funded by the Federal Ministry of Education and Research in Germany (BMBF) has the aim to create a model system that can provide reliable decadal forecasts on climate and weather. The model system to be developed will be novel in several aspects, with great challenges for the methodology development. This concerns especially the determination of the initial conditions, the inclusion into the model of processes relevant to decadal predictions, the increase of the spatial resolution through regionalisation, the improvement or adjustment of statistical post-processing, and finally the synthesis and validation of the entire model system. Therefore, a standardized evaluation system will be part of the MiKlip system to validate it - developed by the project 'Integrated data and evaluation system for decadal scale prediction' (INTEGRATION). The presentation gives an overview of the different linkages of such a project, shows the different development stages and gives an outlook for users and possible end users in climate service. The technical interface combines all projects inside of MiKlip and invites them to participate in a common evaluation system. The system design and the validation strategy from a standalone tool in the beginning to a user friendly web based system using GRID technologies to an integrated part of the operational MiKlip system for industry and society will give the opportunity to enhance the MiKlip strategy. First results of different possibilities of such a system will be shown to present the scientific background through Taylor diagrams, ensemble skill scores and e.g. climatological means to show the usability and possibilities of MiKlip and the INTEGRATION project.

  14. An Online Evaluation of Operating Reserve for System Security

    OpenAIRE

    Le-Ren Chang-Chien; Yin-Juin Lin; Chin-Chung Wu

    2007-01-01

    Utilities use operating reserve for frequency regulation.To ensure that the operating frequency and system security are well maintained, the operating grid codes always specify that the reserve quantity and response rate should meet some prescribed levels. This paper proposes a methodology to evaluate system's contingency reserve for an isolated power network. With the presented algorithm to estimate system's frequency response characteristic, an online allocation of contingency reserve would...

  15. GO evaluation of a PWR spray system. Final report

    International Nuclear Information System (INIS)

    Long, W.T.

    1975-08-01

    GO is a reliability analysis methodology developed over the years from 1960 to the present by Kaman Sciences Corporation, Colorado Springs, Colorado. In this report the GO methodology is presented and its application demonstrated by performing a reliability analysis of a conceptual PWR Containment Spray System. Certain numerical results obtained are compared with those of a prior fault tree analysis of the same system as documented in the 11 January 1973 draft report, A Fault Tree Evaluation of a PWR Spray System

  16. Experimental evaluation of an expert system for nuclear reactor operators

    International Nuclear Information System (INIS)

    Nelson, W.R.

    1984-10-01

    The United States Nuclear Regulatory Commission (USNRC) is supporting a program for the experimental evaluation of an expert system for nuclear reactor operators. A prototype expert system, called the Response Tree System, has been developed and implemented at INEL. The Response Tree System is designed to assess the status of a reactor system following an accident and recommend corrective actions to reactor operators. The system is implemented using color graphic displays and is driven by a computer simulation of the reactor system. Control of the system is accomplished using a transparent touch panel. Controlled experiments are being conducted to measure performance differences between operators using the Response Tree System and those not using it to respond to simulated accident situations. This paper summarizes the methodology and results of the evaluation of the Response Tree System, including the quantitative results obtained in the experiments thus far. Design features of the Response Tree System are discussed, and general conclusions regarding the applicability of expert systems in reactor control rooms are presented

  17. Rural applications of Advanced Traveler Information Systems : evaluation of satellite communications systems for mayday applications

    Science.gov (United States)

    This report documents the results of an evaluation of satellite communication systems for mayday applications conducted as part of the Rural Applications of Advanced Traveler Information Systems (ATIS) study. It focuses on satellite communications sy...

  18. Abreu System - a dosimetric system to evaluate basic functioning parameters of roentgenography equipment

    International Nuclear Information System (INIS)

    Feital, J.C.

    1988-01-01

    This work shows a system to evaluate the half-value thickness of X-ray bundle. This system consists in a card with an aluminium filter, thermoluminescent dosemeter of lithium fluoride and radiographics films. )C.G.C.) [pt

  19. ISOS: A job evaluation system to implement comparable worth

    Directory of Open Access Journals (Sweden)

    Albert Corominas

    2008-01-01

    Full Text Available A fair pay structure is an essential element of the personnel policy of a firm. If the pay structure is perceived as arbitrary by the members of the staff, it becomes a cause of disturbance of the labor relations. Particularly, a pay structure is unfair if it discriminates against women. Job evaluation is a traditional tool used by companies to assist in the process of determining pay structures that can be also useful to detect and combat wage discrimination, since allow determining whether two jobs are of comparable worth or not. Although there are many kinds of systems, authors agree when defining point factor methods as the most appropriate and fair job evaluation systems. However, even being well defined from a technical point of view, most existing systems give discriminatory results regarding to gender. ISOS, a new job evaluation system which is described in this paper, has been designed, with the aim to define a neutral system with regard to gender, based on present jobs characteristics, existing job evaluation systems and job description questionnaires, international experts’ knowledge and a wide body of literature on gender discrimination and its relation with job evaluation. Using ISOS can contribute to detect, combat and eliminate part of the existing wage discrimination in general and, in particular, against women. ISOS includes all aspects of the work so no characteristics are omitted. The system can be applied in any company and to evaluate any job, and offers flexibility to be adapted to the specific characteristics of an organization. ISOS can also be used to detect and combat wage discrimination. Furthermore, characteristics of present jobs, such as cross-training or flexible working time, are also included so the system can be considered innovative in a very traditional field of industrial engineering.

  20. Methods for reliability evaluation of trust and reputation systems

    Science.gov (United States)

    Janiszewski, Marek B.

    2016-09-01

    Trust and reputation systems are a systematic approach to build security on the basis of observations of node's behaviour. Exchange of node's opinions about other nodes is very useful to indicate nodes which act selfishly or maliciously. The idea behind trust and reputation systems gets significance because of the fact that conventional security measures (based on cryptography) are often not sufficient. Trust and reputation systems can be used in various types of networks such as WSN, MANET, P2P and also in e-commerce applications. Trust and reputation systems give not only benefits but also could be a thread itself. Many attacks aim at trust and reputation systems exist, but such attacks still have not gain enough attention of research teams. Moreover, joint effects of many of known attacks have been determined as a very interesting field of research. Lack of an acknowledged methodology of evaluation of trust and reputation systems is a serious problem. This paper aims at presenting various approaches of evaluation such systems. This work also contains a description of generalization of many trust and reputation systems which can be used to evaluate reliability of such systems in the context of preventing various attacks.

  1. Using Expert Systems in Evaluation of the State of High Voltage Machine Insulation Systems

    Directory of Open Access Journals (Sweden)

    K. Záliš

    2000-01-01

    Full Text Available Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used offline diagnostic methods for the diagnostic of high voltage insulation of rotating machines, non-rotating machines and insulating oils. The CVEX expert system evaluates the discharge activity on high voltage electrical machines and equipment by means of an off-line measurement. The CVEXON expert system is for evaluating the discharge activity by on-line measurement, and the ALTONEX expert system is the expert system for on-line monitoring of rotating machines. These developed expert systems are also used for educating students (in bachelor, master and post-graduate studies and in courses which are organized for practicing engineers and technicians and for specialists in the electrical power engineering branch. A complex project has recently been set up to evaluate the measurement of partial discharges. Two parallel expert systems for evaluating partial dischatge activity on high voltage electrical machines will work at the same time in this complex evaluating system.

  2. Evaluating the success of an emergency response medical information system.

    Science.gov (United States)

    Petter, Stacie; Fruhling, Ann

    2011-07-01

    STATPack™ is an information system used to aid in the diagnosis of pathogens in hospitals and state public health laboratories. STATPack™ is used as a communication and telemedicine diagnosis tool during emergencies. This paper explores the success of this emergency response medical information system (ERMIS) using a well-known framework of information systems success developed by DeLone and McLean. Using an online survey, the entire population of STATPack™ users evaluated the success of the information system by considering system quality, information quality, system use, intention to use, user satisfaction, individual impact, and organizational impact. The results indicate that the overall quality of this ERMIS (i.e., system quality, information quality, and service quality) has a positive impact on both user satisfaction and intention to use the system. However, given the nature of ERMIS, overall quality does not necessarily predict use of the system. Moreover, the user's satisfaction with the information system positively affected the intention to use the system. User satisfaction, intention to use, and system use had a positive influence on the system's impact on the individual. Finally, the organizational impacts of the system were positively influenced by use of the system and the system's individual impact on the user. The results of the study demonstrate how to evaluate the success of an ERMIS as well as introduce potential changes in how one applies the DeLone and McLean success model in an emergency response medical information system context. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    Science.gov (United States)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  4. Clinical evaluation of the FreeStyle Precision Pro system.

    Science.gov (United States)

    Brazg, Ronald; Hughes, Kristen; Martin, Pamela; Coard, Julie; Toffaletti, John; McDonnell, Elizabeth; Taylor, Elizabeth; Farrell, Lausanne; Patel, Mona; Ward, Jeanne; Chen, Ting; Alva, Shridhara; Ng, Ronald

    2013-06-05

    A new version of international standard (ISO 15197) and CLSI Guideline (POCT12) with more stringent accuracy criteria are near publication. We evaluated the glucose test performance of the FreeStyle Precision Pro system, a new blood glucose monitoring system (BGMS) designed to enhance accuracy for point-of-care testing (POCT). Precision, interference and system accuracy with 503 blood samples from capillary, venous and arterial sources were evaluated in a multicenter study. Study results were analyzed and presented in accordance with the specifications and recommendations of the final draft ISO 15197 and the new POCT12. The FreeStyle Precision Pro system demonstrated acceptable precision (CV FreeStyle Precision Pro system met the tighter accuracy requirements, providing a means for enhancing accuracy for point-of-care blood glucose monitoring. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Seismic evaluation of piping systems using screening criteria

    International Nuclear Information System (INIS)

    Campbell, R.D.; Landers, D.F.; Minichiello, J.C.; Slagis, G.C.; Antaki, G.A.

    1994-01-01

    This document may be used by a qualified review team to identify potential sources of seismically induced failure in a piping system. Failure refers to the inability of a piping system to perform its expected function following an earthquake, as defined in Table 1. The screens may be used alone or with the Seismic Qualification Utility Group -- Generic Implementation Procedure (SQUG-GIP), depending on the piping system's required function, listed in Table 1. Features of a piping system which do not the screening criteria are called outliers. Outliers must either be resolved through further evaluations, or be considered a potential source of seismically induced failure. Outlier evaluations, which do not necessarily require the qualification of a complete piping system by stress analysis, may be based on one or more of the following: simple calculations of pipe spans, search of the test or experience data, vendor data, industry practice, etc

  6. Thermal management evaluation of the complex electro-optical system

    Directory of Open Access Journals (Sweden)

    Nijemčević Srećko S.

    2017-01-01

    Full Text Available The thermal management of a complex electro-optical system aimed for outdoor application is challenging task due to the requirement of having an air-sealed enclosure, harsh working environment, and an additional thermal load generated by sunlight. It is essential to consider the effect of heating loads in the system components, as well as the internal temperature distribution, that can have influence on the system life expectancy, operational readiness and parameters, and possibility for catastrophic failure. The main objective of this paper is to analyze internal temperature distribution and evaluate its influence on system component operation capability. The electro-optical system simplified model was defined and related thermal balance simulation model based on Solid Works thermal analysis module was set and applied for temperature distribution calculation. Various outdoor environment scenarios were compared to evaluate system temperature distribution and evaluate its influence on system operation, reliability, and life time in application environment. This work was done during the design process as a part of the electro-optical system optimization. The results show that temperature distribution will not be cause for catastrophic failure and malfunction operation during operation in the expected environment.

  7. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    Science.gov (United States)

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. A Process For Performance Evaluation Of Real-Time Systems

    Directory of Open Access Journals (Sweden)

    Andrew J. Kornecki

    2003-12-01

    Full Text Available Real-time developers and engineers must not only meet the system functional requirements, but also the stringent timing requirements. One of the critical decisions leading to meeting these timing requirements is the selection of an operating system under which the software will be developed and run. Although there is ample documentation on real-time systems performance and evaluation, little can be found that combines such information into an efficient process for use by developers. As the software industry moves towards clearly defined processes, creation of appropriate guidelines describing a process for performance evaluation of real-time system would greatly benefit real-time developers. This technology transition research focuses on developing such a process. PROPERT (PROcess for Performance Evaluation of Real Time systems - the process described in this paper - is based upon established techniques for evaluating real-time systems. It organizes already existing real-time performance criteria and assessment techniques in a manner consistent with a well-formed process, based on the Personal Software Process concepts.

  9. Evaluation of hybrid power system alternatives: a case study

    International Nuclear Information System (INIS)

    Rosenthal, Andrew L.

    1999-01-01

    Pursuant to executive and statutory policies, the National Park Service (NPS) has been evaluating the use of photovoltaic (PV) hybrid power systems, for many of its remote, off-grid areas. This paper reports the results of a detailed technical and economic evaluation for one such area: the Needles District of Canyonlands National Park. The study evaluates the presented power systems and five alternative power generation configurations, four of which utilise PV. Projections are provided for the generator run-time and fuel use associated with each configuration as well as all initial and future costs. Included in the study are specific recommendations for energy efficiency improvements at the site. Results show that the generation systems presently in use, two full-time diesel generators, has the lowest conventional 20-year life cycle costs (LCC) of the six systems evaluated. However, when emissions costs are included (per NPS guidelines), several of the PV hybrid alternatives attain a lower LCC than the diesel-only systems. General discussion of the effects of initial versus future costs of PV hybrids as they compare with engine generator system is presented. (Author)

  10. [Monitoring evaluation system for high-specialty hospitals].

    Science.gov (United States)

    Fajardo Dolci, Germán; Aguirre Gas, Héctor G; Robledo Galván, Héctor

    2011-01-01

    Hospital evaluation is a fundamental process to identify medical units' objective compliance, to analyze efficiency of resource use and allocation, institutional values and mission alignment, patient safety and quality standards, contributions to research and medical education, and the degree of coordination among medical units and the health system as a whole. We propose an evaluation system for highly specialized regional hospitals through the monitoring of performance indicators. The following are established as base thematic elements in the construction of indicators: safe facilities and equipment, financial situation, human resources management, policy management, organizational climate, clinical activity, quality and patient safety, continuity of care, patients' and providers' rights and obligations, teaching, research, social responsibility, coordination mechanisms. Monitoring refers to the planned and systematic evaluation of valid and reliable indicators, aimed at identifying problems and opportunity areas. Moreover, evaluation is a powerful tool to strengthen decision-making and accountability in medical units.

  11. Development of multilateral comparative evaluation method for fuel cycle system

    International Nuclear Information System (INIS)

    Tamaki, Hitoshi; Ikushima, Takeshi; Nomura, Yasushi; Nakajima, Kiyoshi.

    1998-03-01

    In the near future, Japanese nuclear fuel cycle system will be promoted by national nuclear energy policy, and it''s options i.e. once through, thermal cycle and fast breeder cycle must be selected by multilateral comparative evaluation method from various aspects of safety, society, economy, and e.t.c. Therefore such a problem can be recognized as a social problem of decision making and applied for AHP (Analytic Hierarchy Process) that can multilaterally and comparatively evaluate the problem. On comparative evaluation, much information are needed for decision making, therefore two kinds of databases having these information have been constructed. And then, the multilateral comparative evaluation method consisting of two kinds of databases and AHP for optimum selection of fuel cycle system option have been developed. (author)

  12. Evaluating Nurses' Satisfaction With Two Nursing Information Systems.

    Science.gov (United States)

    Khajouei, Reza; Abbasi, Reza

    2017-06-01

    Evaluating user satisfaction is one of the methods to ensure the usability of information systems. Considering the importance of nursing information systems in patient health, the objective of this study is to evaluate nurses' satisfaction with two widely used nursing information systems (Peyvand Dadeh and Tirazhe) in Iran. This descriptive-analytical study was done on 230 nurses in all teaching hospitals of Kerman University of Medical Sciences in 2015. Data were collected using an augmented version of a questionnaire developed by IBM. Data were analyzed by SPSS.16 using descriptive and analytical statistical methods including t test, analysis of variance, and Pearson correlation coefficient. The mean of overall satisfaction with the two systems was 61 ± 2.2 and 74 ± 2.4, respectively. The mean of satisfaction with different systems dimensions, that is, ease of use, information quality, and interface quality, was, respectively, 24 ± 1.9, 26 ± 9.7, and 12 ± 4.7 for Tirazhe and 29 ± 1.1, 39 ± 1.04 and 13 ± 5.3 for Peyvand Dadeh system. Nurses' satisfaction with both systems was at a medium level. The majority of nurses were relatively satisfied with the information quality and user interface quality of these systems. The results suggest that designing nursing information systems in accordance with their users' need improves usability. Hence, policy and decision makers of healthcare institutions should invest on usability when purchasing such systems.

  13. Shielding Design and Radiation Shielding Evaluation for LSDS System Facility

    International Nuclear Information System (INIS)

    Kim, Younggook; Kim, Jeongdong; Lee, Yongdeok

    2015-01-01

    As the system characteristics, the target in the spectrometer emits approximately 1012 neutrons/s. To efficiently shield the neutron, the shielding door designs are proposed for the LSDS system through a comparison of the direct shield and maze designs. Hence, to guarantee the radiation safety for the facility, the door design is a compulsory course of the development of the LSDS system. To improve the shielding rates, 250x250 covering structure was added as a subsidiary around the spectrometer. In this study, the evaluations of the suggested shielding designs were conducted using MCNP code. The suggested door design and covering structures can shield the neutron efficiently, thus all evaluations of all conditions are satisfied within the public dose limits. From the Monte Carlo code simulation, Resin(Indoor type) and Tungsten(Outdoor type) were selected as the shielding door materials. From a comparative evaluation of the door thickness, In and Out door thickness was selected 50 cm

  14. Research on the Evaluation System for Rural Public Safety Planning

    Institute of Scientific and Technical Information of China (English)

    Ming; SUN; Jianxin; YAN

    2014-01-01

    The indicator evaluation system is introduced to the study of rural public safety planning in this article.By researching the current rural public safety planning and environmental carrying capacity,we select some carrying capacity indicators influencing the rural public safety,such as land,population,ecological environment,water resources,infrastructure,economy and society,to establish the environmental carrying capacity indicator system.We standardize the indicators,use gray correlation analysis method to determine the weight of indicators,and make DEA evaluation of the indicator system,to obtain the evaluation results as the basis for decision making in rural safety planning,and provide scientific and quantified technical support for rural public safety planning.

  15. Study on uncertainty evaluation system for the safety evaluation of interim spent fuel storage facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Hyeon; Shin, Myeong Won; Rhy, Seok Jin; Cho, Dong Keon; Park, Dong Hwan [Kyunghee Univ., Seoul (Korea, Republic of); Cheong, Beom Jin [Minstry of Science and Technology, Gwacheon (Korea, Republic of)

    1998-03-15

    The main objective os to develop a technical standards for the facility operation of the interm, spent fuel storage facility and to develop a draft for the technical criteria to be legislated. The another objective os to define a uncertainty evaluation system for burn up credit application in criticality analysis and to investigate an applicability of this topic for future regulatory activity. Investigate a status of art for the operational criteria of spent fuel interm wet storage. Collect relevant laws, decree, notices and standards related to the operation of storage facility and study on the legislation system. Develop a draft of technical standards and criteria to be legislated. Define an evaluation system for the uncertainty analysis and study on the status of art in the field of criticality safety analysis. Develop an uncertainty evaluation system in criticality analysis with burnup credit and investigate an applicability as well as its benefits of this policy.

  16. Evaluating Management Information Systems, A Protocol for Automated Peer Review Systems

    Science.gov (United States)

    Black, Gordon C.

    1980-01-01

    This paper discusses key issues in evaluating an automated Peer Review System. Included are the conceptual base, design, steps in planning structural components, operation parameters, criteria, costs and a detailed outline or protocol for use in the evaluation. At the heart of the Peer Review System is the criteria utilized for measuring quality. Criteria evaluation should embrace, as a minimum, appropriateness, validity and reliability, and completemess or comprehensiveness of content. Such an evaluation is not complete without determining the impact (clinical outcome) of the service system or the patient and the population served.

  17. Performance Evaluation of Two Different Usability Evaluation Methods in the Context of Collaborative Writing Systems

    OpenAIRE

    Bakhtyar, Shoaib; Afridi, Qaisar Zaman

    2010-01-01

    In today’s world of rapid technological development one cannot deny the importance of collaborative writing systems. Besides many advantages of a collaborative writing system the major one is to allow its end users to work in collaboration with each other without having to physically meet. In the past various researches has been carried out for the usability evaluation of collaborative writing systems using the think aloud protocol method however there is no study conducted on the comparison ...

  18. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  19. Objective Evaluation in an Online Geographic Information System Certificate Program

    OpenAIRE

    Scott L. WALKER

    2005-01-01

    Objective Evaluation in an Online Geographic Information System Certificate Program Asst. Professor. Dr. Scott L. WALKER Texas State University-San Marcos San Marcos, Texas, USA ABSTRACT Departmental decisions regarding distance education programs can be subject to subjective decision-making processes influenced by external factors such as strong faculty opinions or pressure to increase student enrolment. This paper outlines an evaluation of a departmental distance-education program....

  20. Usability evaluation of complex systems. A literature review

    International Nuclear Information System (INIS)

    Norros, L.; Savioja, P.

    2004-04-01

    In this literature study the task of usability evaluation is approached through recent publications and known practises. The scope of the reviewed literature and the overall problematic of evaluating complex systems are first defined. Then existing evaluation methods and tools and a set of design guidelines and standards is introduced. In there view the distinction between the evaluation of the design process and evaluation of the outcome of the design process is made. Also the existing criteria for usability is provided. These criteria can be used as measures in the evaluation procedures described in the previous chapter. Then, the problem of validity in the evaluation and validation procedures of complex cognitive systems is shortly discusses. The final chapter covers the conclusions of the literature review. There is a need for deepening the relationship between usage and design. Usage must be the driver also in the design of process technology, plant's safety, and instrumentation and control as well as that of the design of man-machine interface. The collaborative activity is called activity-oriented design. In order to enable activity-oriented design we need to create design methods that drive the design activity into this direction. Criteria for evaluating what is good design are not available in present standards. Criteria for good tools and practices must consider human in a favourable role in the various tasks of operating an industrial plant as opposed to the view of human as a source of error. This is the way to create an optimal system, which takes advantage of the unique capabilities of both the human operators and the automation systems. (orig.)

  1. Remote Excavation System technology evaluation report: Buried Waste Robotics Program

    International Nuclear Information System (INIS)

    1993-09-01

    This document describes the results from the Remote Excavation System demonstration and testing conducted at the Idaho National Engineering Laboratory during June and July 1993. The purpose of the demonstration was to ascertain the feasibility of the system for skimming soil and removing various types of buried waste in a safe manner and within all regulatory requirements, and to compare the performances of manual and remote operation of a backhoe. The procedures and goals of the demonstration were previously defined in The Remote Excavation System Test Plan, which served as a guideline for evaluating the various components of the system and discussed the procedures used to conduct the tests

  2. Discriminator/time interval meter system evaluation report

    International Nuclear Information System (INIS)

    Condreva, K.J.

    1976-01-01

    The purpose of this report is to discuss the evaluation of a modular prototype Discriminator/Time Interval Meter data acquisition unit as a useful tool in a digital diagnostics system. The characteristics, operation and calibration of each of the hardware components are discussed in some detail. A discussion of the system calibration, operation, and data ingestion and reduction is also given. System test results to date are given and discussed. Finally, recommendations and conclusions concerning the capabilities of the Discriminator/T.I.M. system based on test and calibration results to date are given

  3. Discriminator/time interval meter system evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Condreva, K. J.

    1976-04-12

    The purpose of this report is to discuss the evaluation of a modular prototype Discriminator/Time Interval Meter data acquisition unit as a useful tool in a digital diagnostics system. The characteristics, operation and calibration of each of the hardware components are discussed in some detail. A discussion of the system calibration, operation, and data ingestion and reduction is also given. System test results to date are given and discussed. Finally, recommendations and conclusions concerning the capabilities of the Discriminator/T.I.M. system based on test and calibration results to date are given.

  4. Evaluation of Workflow Management Systems - A Meta Model Approach

    Directory of Open Access Journals (Sweden)

    Michael Rosemann

    1998-11-01

    Full Text Available The automated enactment of processes through the use of workflow management systems enables the outsourcing of the control flow from application systems. By now a large number of systems, that follow different workflow paradigms, are available. This leads to the problem of selecting the appropriate workflow management system for a given situation. In this paper we outline the benefits of a meta model approach for the evaluation and comparison of different workflow management systems. After a general introduction on the topic of meta modeling the meta models of the workflow management systems WorkParty (Siemens Nixdorf and FlowMark (IBM are compared as an example. These product specific meta models can be generalized to meta reference models, which helps to specify a workflow methodology. Exemplary, an organisational reference meta model is presented, which helps users in specifying their requirements for a workflow management system.

  5. Study, design and evaluation of nuclear reactor computer control system

    International Nuclear Information System (INIS)

    Menacer, S.

    1988-01-01

    Nuclear reactor control is a complex process that varies with each reactor and there is no universal agreement as to the best type of control system. After the use of conventional systems for a long time, attention turned towards digital techniques in the reactor control system. This interest emerged because of the difficulties faced in the data manipulation, mainly for post-incident analysis. However, it is not sufficient to insert a computer in a system to solve all the data-handling problems and also the insertion of a computer in a real-time system is not without any effect on the overall system. The scope of this thesis is to show the important parameters that have to be taken into account when choosing and evaluate the performances of the selected system

  6. Evaluation of several corrosion protective coating systems on aluminum

    Science.gov (United States)

    Higgins, R. H.

    1981-01-01

    A study of several protective coating systems for use on aluminum in seawater/seacoast environments was conducted to review the developments made on protective coatings since early in the Space Shuttle program and to perform comparative studies on these coatings to determine their effectiveness for providing corrosion protection during exposure to seawater/seacoast environments. Panels of 2219-T87 aluminum were coated with 21 different systems and exposed to a 5 percent salt spray for 4000 hr. Application properties, adhesion measurements, heat resistance and corrosion protection were evaluated. For comparative studies, the presently specified Bostik epoxy system used on the SRB structures was included. Results of these tests indicate four systems with outstanding performance and four additional systems with protection almost as good. These systems are based on a chromated pretreatment, a chromate epoxy primer, and a polyurethane topcoat. Consideration for one of these systems should be included for those applications where superior corrosion protection for aluminum surfaces is required.

  7. INPRO Methodology to evaluate the Mexico nuclear energy system

    International Nuclear Information System (INIS)

    Cruz S, R. R.; Martin del C, C.

    2016-09-01

    The International Atomic Energy Agency has developed the so-called International Project on Fuel Cycles and Innovative Nuclear Reactors (INPRO), in order to make nuclear energy available to meet the energy needs of the 21 century, in a sustainable way. One of the tasks of the project is the evaluation of the nuclear systems, to check whether they meet the objectives of the project and whether they are sustainable. This paper explains the rationale and general characteristics of the project in the evaluation of nuclear energy systems based on the concept of sustainable development. It describes the methodology developed to carry out this evaluation, divided into seven areas, such as economic, environmental, security, etc., which together make up the sustainable development of energy through nuclear systems. The economic area is analyzed and the evaluation criteria and parameters established by INPRO are discussed, in order to evaluate the Mexican nuclear energy system using Nest (software developed within the same project) as a tool to support the economic evaluation of nuclear systems. Based on the energy strategy proposed by the Energy Secretary of the Mexican Government which seeks to reduce the greenhouse gas emissions from the national electricity generation park, two types of reactor of currently available technology (A BWR and AP1000), were compared and these in turn with other alternative energy generation technologies, such as combined cycle, geothermal and wind plants. Also, the results of the application of the INPRO methodology are presented. Finally, the recommendations on actions that could lead the Mexican nuclear energy system towards sustainable development and conclusions on the application of the methodology to the Mexican case are mentioned. (Author)

  8. Hanford high-level waste melter system evaluation data packages

    International Nuclear Information System (INIS)

    Elliott, M.L.; Shafer, P.J.; Lamar, D.A.; Merrill, R.A.; Grunewald, W.; Roth, G.; Tobie, W.

    1996-03-01

    The Tank Waste Remediation System is selecting a reference melter system for the Hanford High-Level Waste vitrification plant. A melter evaluation was conducted in FY 1994 to narrow down the long list of potential melter technologies to a few for testing. A formal evaluation was performed by a Melter Selection Working Group (MSWG), which met in June and August 1994. At the June meeting, MSWG evaluated 15 technologies and selected six for more thorough evaluation at the Aug. meeting. All 6 were variations of joule-heated or induction-heated melters. Between the June and August meetings, Hanford site staff and consultants compiled data packages for each of the six melter technologies as well as variants of the baseline technologies. Information was solicited from melter candidate vendors to supplement existing information. This document contains the data packages compiled to provide background information to MSWG in support of the evaluation of the six technologies. (A separate evaluation was performed by Fluor Daniel, Inc. to identify balance of plant impacts if a given melter system was selected.)

  9. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  10. EMCAS: An evaluation methodology for safeguards and security systems

    International Nuclear Information System (INIS)

    Eggers, R.F.; Giese, E.W.; Bichl, F.J.

    1987-01-01

    EMCAS is an evaluation methodology for safeguards and security systems. It provides a score card of projected or actual system performance for several areas of system operation. In one area, the performance of material control and accounting and security systems, which jointly defend against the insider threat to divert or steal special nuclear material (SNM) using stealth and deceit, is evaluated. Time-dependent and time-independent risk equations are used for both diversion and theft risk calculations. In the case of loss detection by material accounting, a detailed timeliness model is provided to determine the combined effects of loss detection sensitivity and timeliness on the overall effectiveness of the material accounting detection procedure. Calculated risks take into account the capabilities of process area containment/surveillance, material accounting mass balance tests, and physical protection barriers and procedures. In addition, EMCAS evaluates the Material Control and Accounting (MC and A) System in the following areas: (1) system capability to detect errors in the official book inventory of SNM, using mass balance accounting methods, (2) system capability to prevent errors from entering the nuclear material data base during periods of operation between mass balance tests, (3) time to conduct inventories and resolve alarms, and (4) time lost from production to carry out material control and accounting loss detection activities. 3 figs., 5 tabs

  11. EMCAS, an evaluation methodology for safeguards and security systems

    International Nuclear Information System (INIS)

    Eggers, R.F.; Giese, E.W.; Bichl, F.J.

    1987-01-01

    EMCAS is an evaluation methodology for safeguards and security systems. It provides a score card of projected or actual system performance for several areas of system operation. In one area, the performance of material control and accounting and security systems, which jointly defend against the insider threat to divert or steal special nuclear material (SNM) using stealth and deceit, is evaluated. Time-dependent and time-independent risk equations are used for both diversion and theft risk calculations. In the case of loss detection by material accounting, a detailed timeliness model is provided to determine the combined effects of loss detection sensitivity and timeliness on the overall effectiveness of the material accounting detection procedure. Calculated risks take into account the capabilities of process area containment/surveillance, material accounting mass balance tests, and physical protection barriers and procedures. In addition, EMCAS evaluates the Material Control and Accounting (MCandA) System in the following areas: (1) system capability to detect errors in the official book inventory of SNM, using mass balance accounting methods, (2) system capability to prevent errors from entering the nuclear material data base during periods of operation between mass balance tests, (3) time to conduct inventories and resolve alarms, and (4) time lost from production to carry out material control and accounting loss detection activities

  12. Evaluation of a flat-panel detector system

    International Nuclear Information System (INIS)

    Sato, Masami; Eguchi, Yoichi; Yamada, Kinichi; Kaga, Yuji; Endo, Yutaka; Yamazaki, Tatsuya

    2001-01-01

    We evaluated the imaging performance of a flat-panel detector digital radiography system (CXDI-11 X-ray Digital Camera, Canon Inc.) and a computed radiography system (FCR9000C-HQ, Fuji Film). The characteristics of the two detectors and of the overall systems were compared. This included evaluation and comparison of the fundamental physical characteristics, including x-ray response curve, modulation transfer function (MTF), Wiener spectra, noise-equivalent quanta, and x-ray tube voltage-dependent detector response. Overall system performance was evaluated using receiver operating characteristic (ROC) analysis. The results of the study showed that the dynamic range of the CXDI-11 measured relative to the input x-ray flux was 10 3 , similar to that of the FCR9000C-HQ. Both systems showed similar final MTFs, although the pre-sampling MTF of the CXDI-11 was better than that of the FCR9000C-HQ. Noise analysis, based on noise-equivalent quanta and Wiener spectra, showed that for normal exposure conditions the CXDI-11 had superior performance. With both systems, x-ray response (system output/incident x-ray exposure) increased with increasing x-ray tube voltage. ROC analysis indicated that the CXDI-11 was superior in overall performance. (author)

  13. Qualitative and quantitative evaluation of solvent systems for countercurrent separation.

    Science.gov (United States)

    Friesen, J Brent; Ahmed, Sana; Pauli, Guido F

    2015-01-16

    Rational solvent system selection for countercurrent chromatography and centrifugal partition chromatography technology (collectively known as countercurrent separation) studies continues to be a scientific challenge as the fundamental questions of comparing polarity range and selectivity within a solvent system family and between putative orthogonal solvent systems remain unanswered. The current emphasis on metabolomic investigations and analysis of complex mixtures necessitates the use of successive orthogonal countercurrent separation (CS) steps as part of complex fractionation protocols. Addressing the broad range of metabolite polarities demands development of new CS solvent systems with appropriate composition, polarity (π), selectivity (σ), and suitability. In this study, a mixture of twenty commercially available natural products, called the GUESSmix, was utilized to evaluate both solvent system polarity and selectively characteristics. Comparisons of GUESSmix analyte partition coefficient (K) values give rise to a measure of solvent system polarity range called the GUESSmix polarity index (GUPI). Solvatochromic dye and electrical permittivity measurements were also evaluated in quantitatively assessing solvent system polarity. The relative selectivity of solvent systems were evaluated with the GUESSmix by calculating the pairwise resolution (αip), the number of analytes found in the sweet spot (Nsw), and the pairwise resolution of those sweet spot analytes (αsw). The combination of these parameters allowed for both intra- and inter-family comparison of solvent system selectivity. Finally, 2-dimensional reciprocal shifted symmetry plots (ReSS(2)) were created to visually compare both the polarities and selectivities of solvent system pairs. This study helps to pave the way to the development of new solvent systems that are amenable to successive orthogonal CS protocols employed in metabolomic studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. A Group Creativity Support System for Dynamic Idea Evaluation

    DEFF Research Database (Denmark)

    Ulrich, Frank

    2015-01-01

    Idea evaluation is necessary in most modern organizations to identify the level of novelty and usefulness of new ideas. However, current idea evaluation research hinders creativity by primarily supporting convergent thinking (narrowing down ideas to a few tangible solutions), while divergent...... thinking (the development of wildly creative and novel thoughts patterns) is discounted. In this paper, this current view of idea evaluation is challenged through the development of a prototype that supports dynamic idea evaluation. The prototype uses knowledge created during evaluative processes...... to facilitate divergent thinking in a Group Creativity Support System (GCSS) designed from state-of-the-art research. The prototype is interpretively explored through a field experiment in a Danish IS research department. Consequently, the prototype demonstrates the ability to including divergent thinking...

  15. Ose evaluation of delay systems in a high threat environment

    International Nuclear Information System (INIS)

    Rich, B.L.; Cook, B.G.

    1988-01-01

    The Office of Security Evaluations (OSE) has in place an Evaluation Program to assist the Department of Energy (DOE) Headquarters and operations office managers by assessing specific elements of protection programs and informing the managers of common strengths and weaknesses of these elements. This information is provided so that sufficient and cost effective protection programs are maintained or enhanced. The subject of this paper is the evaluation of delay systems in the high-threat environment defined for sensitive DOE security interests such as special nuclear materials, nuclear weapons, and related classified devices and information

  16. PERFORMANCE EVALUATION OF PENSION FUNDS WITH FUZZY EXPERT SYSTEM

    Directory of Open Access Journals (Sweden)

    SERDAR KORUKOĞLU

    2013-06-01

    Full Text Available Financial rating and ranking firms often use linguistic instead of numerical values. When input data are mostly qualitative and are based on subjective knowledge of experts, the Fuzzy Set Theory provides a solid mathematical model to represent and handle these data. The aim of this study is developing a fuzzy expert model to evaluate the performance of the pension funds by using their risk and return values. The method is used for evaluating the performance of the randomly selected of twenty seven Turkish pension funds. The obtained results proved that the fuzzy expert system is appropriate and consistent for performance evaluation.

  17. Cardiovascular System Sonographic Evaluation Algorithm: A New Sonographic Algorithm for Evaluation of the Fetal Cardiovascular System in the Second Trimester.

    Science.gov (United States)

    De León-Luis, Juan; Bravo, Coral; Gámez, Francisco; Ortiz-Quintana, Luis

    2015-07-01

    To evaluate the reproducibility and feasibility of the new cardiovascular system sonographic evaluation algorithm for studying the extended fetal cardiovascular system, including the portal, thymic, and supra-aortic areas, in the second trimester of pregnancy (19-22 weeks). We performed a cross-sectional study of pregnant women with healthy fetuses (singleton and twin pregnancies) attending our center from March to August 2011. The extended fetal cardiovascular system was evaluated by following the new algorithm, a sequential acquisition of axial views comprising the following (caudal to cranial): I, portal sinus; II, ductus venosus; III, hepatic veins; IV, 4-chamber view; V, left ventricular outflow tract; VI, right ventricular outflow tract; VII, 3-vessel and trachea view; VIII, thy-box; and IX, subclavian arteries. Interobserver agreement on the feasibility and exploration time was estimated in a subgroup of patients. The feasibility and exploration time were determined for the main cohort. Maternal, fetal, and sonographic factors affecting both features were evaluated. Interobserver agreement was excellent for all views except view VIII; the difference in the mean exploration time between observers was 1.5 minutes (95% confidence interval, 0.7-2.1 minutes; P cardiovascular system sonographic evaluation algorithm is a reproducible and feasible approach for exploration of the extended fetal cardiovascular system in a second-trimester scan. It can be used to explore these areas in normal and abnormal conditions and provides an integrated image of extended fetal cardiovascular anatomy. © 2015 by the American Institute of Ultrasound in Medicine.

  18. Evaluation of a computerized system for mechanical ventilation of infants.

    Science.gov (United States)

    Tehrani, Fleur T; Abbasi, Soraya

    2009-04-01

    To evaluate a computerized system for mechanical ventilation of infants. FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fraction of inspired oxygen (F(IO2)), minute ventilation, and control of weaning. It is used as an open-loop decision support system or as a closed-loop technique. Blood gas and ventilation data were collected from 12 infants in the neonatal intensive care at baseline and at the next round of evaluation. This data were input to open-loop version of FLEX. The system recommendations were compared to clinical determinations. FLEX recommended values for ventilation were on the average within 25% and 16.5% of the measured values at baseline and at the next round of evaluation, respectively. For F(IO2) and PEEP, FLEX recommended values were in general agreement with the clinical settings. FLEX recommendations for weaning were the same as the clinical determinations 50% of the time at baseline and 55% of the time at the next round of evaluation. FLEX did not recommend weaning for infants with weak spontaneous breathing effort or those who showed signs of dyspnea. A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.

  19. The evaluation of a web-based incident reporting system.

    Science.gov (United States)

    Kuo, Ya-Hui; Lee, Ting-Ting; Mills, Mary Etta; Lin, Kuan-Chia

    2012-07-01

    A Web-based reporting system is essential to report incident events anonymously and confidentially. The purpose of this study was to evaluate a Web-based reporting system in Taiwan. User satisfaction and impact of system use were evaluated through a survey answered by 249 nurses. Incident events reported in paper and electronic systems were collected for comparison purposes. Study variables included system user satisfaction, willingness to report, number of reports, severity of the events, and efficiency of the reporting process. Results revealed that senior nurses were less willing to report events, nurses on internal medicine units had higher satisfaction than others, and lowest satisfaction was related to the time it took to file a report. In addition, the Web-based reporting system was used more often than the paper system. The percentages of events reported were significantly higher in the Web-based system in laboratory, environment/device, and incidents occurring in other units, whereas the proportions of reports involving bedsores and dislocation of endotracheal tubes were decreased. Finally, moderate injury event reporting decreased, whereas minor or minimal injury event reporting increased. The study recommends that the data entry process be simplified and the network system be improved to increase user satisfaction and reporting rates.

  20. Using ISO 25040 standard for evaluating electronic health record systems.

    Science.gov (United States)

    Oliveira, Marília; Novaes, Magdala; Vasconcelos, Alexandre

    2013-01-01

    Quality of electronic health record systems (EHR-S) is one of the key points in the discussion about the safe use of this kind of system. It stimulates creation of technical standards and certifications in order to establish the minimum requirements expected for these systems. [1] In other side, EHR-S suppliers need to invest in evaluation of their products to provide systems according to these requirements. This work presents a proposal of use ISO 25040 standard, which focuses on the evaluation of software products, for define a model of evaluation of EHR-S in relation to Brazilian Certification for Electronic Health Record Systems - SBIS-CFM Certification. Proposal instantiates the process described in ISO 25040 standard using the set of requirements that is scope of the Brazilian certification. As first results, this research has produced an evaluation model and a scale for classify an EHR-S about its compliance level in relation to certification. This work in progress is part for the acquisition of the degree of master in Computer Science at the Federal University of Pernambuco.

  1. Evaluation of the utility of a glycemic pattern identification system.

    Science.gov (United States)

    Otto, Erik A; Tannan, Vinay

    2014-07-01

    With the increasing prevalence of systems allowing automated, real-time transmission of blood glucose data there is a need for pattern recognition techniques that can inform of deleterious patterns in glycemic control when people test. We evaluated the utility of pattern identification with a novel pattern identification system named Vigilant™ and compared it to standard pattern identification methods in diabetes. To characterize the importance of an identified pattern we evaluated the relative risk of future hypoglycemic and hyperglycemic events in diurnal periods following identification of a pattern in a data set of 536 patients with diabetes. We evaluated events 2 days, 7 days, 30 days, and 61-90 days from pattern identification, across diabetes types and cohorts of glycemic control, and also compared the system to 6 pattern identification methods consisting of deleterious event counts and percentages over 5-, 14-, and 30-day windows. Episodes of hypoglycemia, hyperglycemia, severe hypoglycemia, and severe hyperglycemia were 120%, 46%, 123%, and 76% more likely after pattern identification, respectively, compared to periods when no pattern was identified. The system was also significantly more predictive of deleterious events than other pattern identification methods evaluated, and was persistently predictive up to 3 months after pattern identification. The system identified patterns that are significantly predictive of deleterious glycemic events, and more so relative to many pattern identification methods used in diabetes management today. Further study will inform how improved pattern identification can lead to improved glycemic control. © 2014 Diabetes Technology Society.

  2. System reliability evaluation of a touch panel manufacturing system with defect rate and reworking

    International Nuclear Information System (INIS)

    Lin, Yi-Kuei; Huang, Cheng-Fu; Chang, Ping-Chen

    2013-01-01

    In recent years, portable consumer electronic products, such as cell phone, GPS, digital camera, tablet PC, and notebook are using touch panel as interface. With the demand of touch panel increases, performance assessment is essential for touch panel production. This paper develops a method to evaluate system reliability of a touch panel manufacturing system (TPMS) with defect rate of each workstation and takes reworking actions into account. The system reliability which evaluates the possibility of demand satisfaction can provide to managers with an understanding of the system capability and can indicate possible improvements. First, we construct a capacitated manufacturing network (CMN) for a TPMS. Second, a decomposition technique is developed to determine the input flow of each workstation based on the CMN. Finally, we generate the minimal capacity vectors that should be provided to satisfy the demand. The system reliability is subsequently evaluated in terms of the minimal capacity vectors. A further decision making issue is discussed to decide a reliable production strategy. -- Graphical abstract: The proposed procedure to evaluate system reliability of the touch panel manufacturing system (TPMS). Highlights: • The system reliability of a touch panel manufacturing system (TPMS) is evaluated. • The reworking actions are taken into account in the TPMS. • A capacitated manufacturing network is constructed for the TPMS. • A procedure is proposed to evaluate system reliability of TPMS

  3. Physical security system effectiveness evaluation: a status report

    International Nuclear Information System (INIS)

    Todd, J.L.; Nickell, W.C.

    1975-01-01

    A method to permit objective comparisons of physical security systems is under development and is expected to be useful in the optimization of system design and in cost benefit analysis. The procedure involves identifying the possible or potential characteristics of a postulated adversary, the counter-measures to deny or diminish adversary success and the response capabilities of the defender. These, in conjunction with system definition information, are evaluated by the use of analytical models which provide a menas of ranking systems against threats. The status of this effort and an overview of the methodology with a brief description of various models being considered for use in effective evaluation are discussed. (U.S.)

  4. SVD-Based Evaluation of Multiplexing in Multipinhole SPECT Systems

    Directory of Open Access Journals (Sweden)

    Aaron K. Jorgensen

    2008-01-01

    Full Text Available Multipinhole SPECT system design is largely a trial-and-error process. General principles can give system designers a general idea of how a system with certain characteristics will perform. However, the specific performance of any particular system is unknown before the system is tested. The development of an objective evaluation method that is not based on experimentation would facilitate the optimization of multipinhole systems. We derive a figure of merit for prediction of SPECT system performance based on the entire singular value spectrum of the system. This figure of merit contains significantly more information than the condition number of the system, and is therefore more revealing of system performance. This figure is then compared with simulated results of several SPECT systems and is shown to correlate well to the results of the simulations. The proposed figure of merit is useful for predicting system performance, but additional steps could be taken to improve its accuracy and applicability. The limits of the proposed method are discussed, and possible improvements to it are proposed.

  5. GESAT: System for management and evaluation of training programs

    International Nuclear Information System (INIS)

    Arjona, O.; Venegas, M.; Rodriguez, L.; Lopez, M.

    1997-01-01

    This paper describe the criteria considered to design the GESAT system, the elements considered to select the relational model, selection of the database language and the main features and possibilities of this system. GESAT allow the management of training programs based on the Systematic Approach to Training. Include the information related with all SAT phases, the results of the job analysis, training plans design, development of materials, training implementation, and the subsequent evaluation

  6. Evaluating pay-as-you-go social security systems

    OpenAIRE

    Bachmann, Andreas; Wüthrich, Kaspar

    2013-01-01

    This paper proposes a new method for welfare analysis of unfunded social security systems. Based on an overlapping generations model with endogenous labor supply, we derive a formula for the evaluation of existing pay-as-you-go social security systems that depends on impulse response functions and projected growth rates only. We propose an implementation strategy based on reduced form estimates of a VAR model that is valid under weak assumptions about the deep structure of the model. Our meth...

  7. Dacryoscintigraph evaluation of the repaired lacrimal drainage system

    International Nuclear Information System (INIS)

    Hoehn, J.G.; Vitale, P.; Elliott, R.A. Jr.

    1976-01-01

    We have used dacryoscintigraphy to study the efficiency of the lacrimal system following the repair of a divided lower canaliculus in 4 children. This test has been reliable in evaluating lacrimal function and suggests that a canaliculus can be repaired and splinted satisfactorily. Our experience with dacryoscintigraphy confirms that it is a safe comfortable, and reliable method for studying the patency of the lacrimal drainage system

  8. Collaborative evaluation of the Abbott yeast identification system.

    OpenAIRE

    Cooper, B H; Prowant, S; Alexander, B; Brunson, D H

    1984-01-01

    The Abbott yeast identification system (Abbott Laboratories, Diagnostics Division, Irving, Tex.) is a 24-h, instrumental method for identifying medically important yeasts, based on matrix analysis of 19 biochemical reactions and the germ tube test. The system was evaluated in two clinical laboratories by using 179 coded isolates, which included a high percentage of the less frequently encountered species. Based upon results with these coded isolates and from previously obtained laboratory dat...

  9. Characterization and evaluation studies on some JAERI dosimetry systems

    International Nuclear Information System (INIS)

    Kojima, T.; Sunaga, H.; Tachibana, H.; Takizawa, H.; Tanaka, R.

    2000-01-01

    Characterization and evaluation studies were carried out on some JAERI dosimetry systems, mainly alanine-ESR, in terms of the influence on the dose response of parameters such as orientation at ESR analysis, and the temperature during irradiation and analysis. Feasibility study for application of these dosimetry systems to electrons with energies lower than 4 MeV and bremsstrahlung (X rays) was also performed parallel to their reliability check through international dose intercomparison. (author)

  10. Tracer gas evaluations of push-pull ventilation system performance.

    Science.gov (United States)

    Ojima, Jun

    2009-01-01

    A push-pull ventilation system is effective for hazardous material exhaustion. Although a push-pull ventilation system has advantages over a local exhaust hood, some laborious adjustments are required. The pertinence of the adjustments is uncertain because it is difficult to evaluate the performance of a push-pull ventilation system quantitatively. In this study, a measurement of the capture efficiency of a push-pull ventilation system was carried out by means of a tracer gas method. The capture efficiency decreased to 39.3-78.5% when blockage material, a dummy worker and a cross draft, were set in the ventilation zone, but the efficiency was 95.1-97.9% when the cross draft was stopped. The results suggest that the uniform flow of a push-pull ventilation system will detour a blockage and the performance of the system will not be reduced unless a cross draft disturbs the uniform flow.

  11. Advanced transport systems analysis, modeling, and evaluation of performances

    CERN Document Server

    Janić, Milan

    2014-01-01

    This book provides a systematic analysis, modeling and evaluation of the performance of advanced transport systems. It offers an innovative approach by presenting a multidimensional examination of the performance of advanced transport systems and transport modes, useful for both theoretical and practical purposes. Advanced transport systems for the twenty-first century are characterized by the superiority of one or several of their infrastructural, technical/technological, operational, economic, environmental, social, and policy performances as compared to their conventional counterparts. The advanced transport systems considered include: Bus Rapid Transit (BRT) and Personal Rapid Transit (PRT) systems in urban area(s), electric and fuel cell passenger cars, high speed tilting trains, High Speed Rail (HSR), Trans Rapid Maglev (TRM), Evacuated Tube Transport system (ETT), advanced commercial subsonic and Supersonic Transport Aircraft (STA), conventionally- and Liquid Hydrogen (LH2)-fuelled commercial air trans...

  12. Design and Evaluation Methods for Underwater Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Lin

    1996-12-31

    This thesis on underwater control systems is written with the designer in mind, assuming that the reader has some knowledge of control theory. It can be used as a text for undergraduate students and engineers. To help readers better understand the system they will be working with, the thesis is organised in a stepwise way. The reader will gain basic knowledge about underwater operations, equipment and control systems. Then the reader will be able to follow the steps to develop a required control system for an underwater equipment by first understanding the characteristics of the design problem, customer requirement, functional requirement, and possible solution, and then to present a mathematical model of the control problem. Having developed the concept, the thesis guides the reader to develop evaluation criteria and different ways to make the decision. The thesis gives an overview of how to achieve a successful design rather than giving the techniques for detailed control system design. Chapter 1 describes underwater operations and systems. Chapter 2 discusses issues of underwater control systems and control methods. Chapter 3 deals with design method and control systems theory, focusing on human-centered control. Chapter 4 discusses methods used to evaluate and rank products, and chapter 5 applies the methods to an example. 113 refs., 115 figs., 80 tabs.

  13. Design and Evaluation Methods for Underwater Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Lin

    1997-12-31

    This thesis on underwater control systems is written with the designer in mind, assuming that the reader has some knowledge of control theory. It can be used as a text for undergraduate students and engineers. To help readers better understand the system they will be working with, the thesis is organised in a stepwise way. The reader will gain basic knowledge about underwater operations, equipment and control systems. Then the reader will be able to follow the steps to develop a required control system for an underwater equipment by first understanding the characteristics of the design problem, customer requirement, functional requirement, and possible solution, and then to present a mathematical model of the control problem. Having developed the concept, the thesis guides the reader to develop evaluation criteria and different ways to make the decision. The thesis gives an overview of how to achieve a successful design rather than giving the techniques for detailed control system design. Chapter 1 describes underwater operations and systems. Chapter 2 discusses issues of underwater control systems and control methods. Chapter 3 deals with design method and control systems theory, focusing on human-centered control. Chapter 4 discusses methods used to evaluate and rank products, and chapter 5 applies the methods to an example. 113 refs., 115 figs., 80 tabs.

  14. Evaluation of FSO System Availability in Haze Condition

    Science.gov (United States)

    Anis, A. A.; Rashidi, C. B. M.; Aljunid, S. A.; Rahman, A. K.

    2018-03-01

    In this paper, we proposed the evaluation of FSO system availability in haze condition. The atmospheric attenuation by weather conditions in the atmosphere as the most challenging problem of FSO system as the system performance is severely degraded and causing the signal optic to be transmitted poorly. The effects of haze condition on the performance of FSO system is stressed out and focused in this paper. From the evaluation of the analysis, designs of FSO system are proposed to obtain a system with improved link performance in haze conditions. The scattering coefficient and the atmospheric attenuation are determined using Beer’s Lambert equation. From the research, the link performance of the system is greatly improved using Design 2 with minimum BER of 10-127127 and maximu m Q Factor of 23.98. The FSO system using Design 2 has better performance compared to Design 1 in haze condition as the optical signals could penetrate the dense haze better without losing much optical power during the transmission to the scattering.

  15. Evaluation of a data dictionary system. [information dissemination and computer systems programs

    Science.gov (United States)

    Driggers, W. G.

    1975-01-01

    The usefulness was investigated of a data dictionary/directory system for achieving optimum benefits from existing and planned investments in computer data files in the Data Systems Development Branch and the Institutional Data Systems Division. Potential applications of the data catalogue system are discussed along with an evaluation of the system. Other topics discussed include data description, data structure, programming aids, programming languages, program networks, and test data.

  16. A Metrics-Based Approach to Intrusion Detection System Evaluation for Distributed Real-Time Systems

    Science.gov (United States)

    2002-04-01

    Based Approach to Intrusion Detection System Evaluation for Distributed Real - Time Systems Authors: G. A. Fink, B. L. Chappell, T. G. Turner, and...Distributed, Security. 1 Introduction Processing and cost requirements are driving future naval combat platforms to use distributed, real - time systems of...distributed, real - time systems . As these systems grow more complex, the timing requirements do not diminish; indeed, they may become more constrained

  17. System Function Evaluation due to Hardware Failure of NSSS Control Systems in the APR1400

    International Nuclear Information System (INIS)

    Kim, Juyoung; Ahn, Myunghoon; Kim, Woogoon; Yim, Hyeongsoon

    2016-01-01

    As the performance and failure modes of the control systems may affect the plant response to accidents or disturbances, an evaluation is done to identify potential control system failure modes resulting from single hardware failures. These failure modes are for use in the analytical evaluations that will be performed to assess the plant responses to various disturbances from the viewpoint of postulated system malfunctions. Failure modes that fall into any of the above categories will affect the performance of the control system and should be considered in the analytical evaluation of the NSSS responses to disturbances. An evaluation was performed to identify the failure modes of the NSSS Control Systems, caused by a hardware component, a common sensing device, and a common power supply. The multiple failure modes across the NSSS control Systems are limited by the improved design features, redundancy within each systems, and segmentation between systems. Also, the effects from the failure modes are expected to be acceptably terminated by the Plant Protection System. The failure modes derived through this evaluation will be further considered in the analytical evaluation of the NSSS responses to disturbances in order to identify the single failures which could create the most adverse conditions during a given transient

  18. A new method to evaluate human-robot system performance

    Science.gov (United States)

    Rodriguez, G.; Weisbin, C. R.

    2003-01-01

    One of the key issues in space exploration is that of deciding what space tasks are best done with humans, with robots, or a suitable combination of each. In general, human and robot skills are complementary. Humans provide as yet unmatched capabilities to perceive, think, and act when faced with anomalies and unforeseen events, but there can be huge potential risks to human safety in getting these benefits. Robots provide complementary skills in being able to work in extremely risky environments, but their ability to perceive, think, and act by themselves is currently not error-free, although these capabilities are continually improving with the emergence of new technologies. Substantial past experience validates these generally qualitative notions. However, there is a need for more rigorously systematic evaluation of human and robot roles, in order to optimize the design and performance of human-robot system architectures using well-defined performance evaluation metrics. This article summarizes a new analytical method to conduct such quantitative evaluations. While the article focuses on evaluating human-robot systems, the method is generally applicable to a much broader class of systems whose performance needs to be evaluated.

  19. Development of an NPP residual lifetime evaluation system

    International Nuclear Information System (INIS)

    Regano, M.; Ibanez, M.; Hevia, F.

    1993-01-01

    Various reasons have given rise to the need for residual life management of Spain's nuclear power plants which lead to the a project for the development of a residual lifetime evaluation system managed by UNESA and supported by the owner groups. This project is described. 1 fig

  20. Development of an operations evaluation system for sinking EDM

    NARCIS (Netherlands)

    Lauwers, B.; Oosterling, J.A.J.; Vanderauwera, W.

    2010-01-01

    This paper describes the development and validation of an operations evaluation system for sinking EDM operations. Based on a given workpiece geometry (e.g. mould), regions to be EDM'ed are automatically indentified. For a given electrode configuration, consisting of one or more regions, EDM

  1. Disability Evaluation System Analysis and Research Annual Report 2017

    Science.gov (United States)

    2017-11-20

    females, other race, enlisted and active duty service members for all services and time periods. • Rates increase as age increases in the Army. For the...Annual Report 2017 Disability Evaluation Systems Analysis and Research Prepared by Accession Medical Standards Analysis and Research Activity ...50 History of hospitalization among active duty service

  2. Design evaluation of the HTGR fuel element size reduction system

    International Nuclear Information System (INIS)

    Strand, J.B.

    1978-06-01

    A fuel element size reduction system for the ''cold'' pilot plant of the General Atomic HTGR Reference Recycle Facility has been designed and tested. This report is both an evaluation of the design based on results of initial tests and a description of those designs which require completion or modification for hot cell use. 11 figures

  3. Performance evaluation of sprinkler irrigation system at Mambilla ...

    African Journals Online (AJOL)

    Variation in discharge can also be adjusted via use of uniform laterals, risers, and nozzles. This study further recommends an incorporation of a soil and water laboratory for the company to aid in monitoring the soil and water quality of the irrigation area. Keywords: Tea, irrigation System, Performance Evaluation ...

  4. Performance Evaluation of Irbene RT-16 Radio Telescope Receiving System

    Directory of Open Access Journals (Sweden)

    Bleiders M.

    2017-12-01

    Full Text Available In the present paper, recent measurement results of refurbished Irbene RT-16 radio telescope receiving system performance are presented. The aim of the research is to evaluate characteristics of RT-16, which will allow carrying out necessary amplitude calibration in both single dish and VLBI observations, to improve the performance of existing system as well as to monitor, control and compare performance if possible changes in the receiving system will occur in future. The evaluated receiving system is 16 m Cassegrain antenna equipped with a cryogenic receiver with frequency range from 4.5 to 8.8 GHz, which is divided into four sub-bands. Multiple calibration sessions have been carried out by observing stable astronomical sources with known flux density by using in-house made total power registration backend. First, pointing offset calibration has been carried out and pointing model coefficients calculated and applied. Then, amplitude calibration, namely antenna sensitivity, calibration diode equivalent flux density and gain curve measurements have been carried out by observing calibration sources at different antenna elevations at each of the receiver sub-bands. Beam patterns have also been evaluated at different frequency bands. As a whole, acquired data will serve as a reference point for comparison in future performance evaluation of RT-16.

  5. Magnetic Resonance Spectroscopy in evaluation of central nervous system

    International Nuclear Information System (INIS)

    Krolicki, L.; Bak, M.; Grieb, P.

    1996-01-01

    The article presents the current results of MR spectroscopy in evaluation of central nervous system. This method is useful in examination of brain ischemia, brain tumors, epilepsy; white matter disorders and degeneration diseases. MR spectroscopy is unique technique for in vivo examination of the brain in physiological and pathophysiological states. (author)

  6. Evaluation of Municipal Solid Waste Management System and ...

    African Journals Online (AJOL)

    This paper reports the evaluation of households' usage of the current solid waste management system (SWMS) within the city of Ilorin, central Nigeria and investigates the determinants of household's willingness-to-Pay (WTP) for its improvement. Data was collected with the aid of a structured questionnaire administered to ...

  7. Evaluation of forest management systems under risk of wildfire

    Science.gov (United States)

    Kari Hyytiainen; Robert G. Haight

    2010-01-01

    We evaluate the economic efficiency of even- and uneven-aged management systems under risk of wildfire. The management problems are formulated for a mixed-conifer stand and approximations of the optimal solutions are obtained using simulation optimization. The Northern Idaho variant of the Forest Vegetation Simulator and its Fire and Fuels Extension is used to predict...

  8. Open Source Library Management Systems: A Multidimensional Evaluation

    Science.gov (United States)

    Balnaves, Edmund

    2008-01-01

    Open source library management systems have improved steadily in the last five years. They now present a credible option for small to medium libraries and library networks. An approach to their evaluation is proposed that takes account of three additional dimensions that only open source can offer: the developer and support community, the source…

  9. Evaluating Frequency Quality of Nordic System using PMU data

    DEFF Research Database (Denmark)

    Xu, Zhao; Østergaard, Jacob; Togeby, Mikael

    2008-01-01

    This paper focuses on analysing frequency quality of Nordic power system using measurements from Phasor Measurement Units (PMU). The PMU data of one year long period is used which has very high time resolution (20 ms per sample) and is able to provide detailed information in evaluating frequency...

  10. Sensory evaluation of heating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Evin, F.; Siekierski, E. [Electricite de France, Research and Development Division, Les Renardieres, Moret Sur Loing (France)

    2002-07-01

    Existing standards and models, such as ISO 7730 or the work of Fanger [Thermal Comfort], are not sufficient to characterise the satisfaction and pleasantness of end-users provided by heating or air conditioning systems. For this reason Electricite de France (EDF) has initiated a project with the aim of using sensory evaluation techniques in the design of HVAC systems. Sensory evaluation has been used for more than 30 years in the food industry, and now involves the cosmetics, the phone and the automotive industries. It is based on a dual evaluation: sensation measurements carried out by a small panel of trained expert assessors; preference studies performed by a large panel of representative consumers. A correlation between the data of both studies is then used to explain the preferences in terms of sensations (preference mapping). The first experiments performed in 1999 and 2000 have provided lists of descriptors of thermal sensation and acoustic sensation associated with heating and air conditioning appliances. They show that it is possible to define discriminative descriptors, to train a panel and to reliably quantify these descriptors. It is then possible to draw the sensory profiles of different heating, ventilation and air conditioning (HVAC) systems. The future experimental laboratory that EDF has decided to build is also presented, where the trained panels and end-users will evaluate the sensations and the preferences of real systems in eight 'realistic environmental chambers' designed, furnished and decorated like offices and flats. (author)

  11. Assessment on Peri-Urban Dairy Production System and Evaluation ...

    African Journals Online (AJOL)

    Assessment on Peri-Urban Dairy Production System and Evaluation of Quality of Cows' Raw Milk: A Case of Shambu, Fincha and Kombolcha Towns of Horro Guduru Wollega Zone, Ethiopia. ... Science, Technology and Arts Research Journal ... Keywords: Bacterial load Ethiopia Horro Guduru Peri-Urban Dairying Raw milk ...

  12. Final evaluation of advanced and current leak detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Carlson, R.; Brewer, W.; Lanham, R.

    1989-01-01

    This report presents the results of a study to evaluate the adequacy of leak detection systems in light water reactors. The sources of numerous reported leaks and methods of detection have been documented. Research to advance the state of the art of acoustic leak detection is presented, and procedures for implementation are discussed

  13. Complex Teacher Evaluation Systems Can Produce Negative Perceptions

    Science.gov (United States)

    Schumacher, Gary

    2010-01-01

    The purpose of this study was to determine teacher perceptions of the impact on instructional practice when using a complex, standards-based performance evaluation system. The study used expectancy theory to investigate teacher expectancy (did they believe they could enhance their practice to the identified program standards?), instrumentality…

  14. Thermodynamic evaluation of the Ti-Al-O ternary system

    International Nuclear Information System (INIS)

    Lee, B.-J.

    1997-01-01

    A thermodynamic evaluation of the Ti-Al-O ternary system has been made by using thermodynamic models for the Gibbs energy of individual phases. A consistent model parameter set was determined so that the calculation of isothermal sections and other thermodynamic quantities becomes possible. The agreement between calculation and corresponding experimental data was generally good along large temperature and composition range. (orig.)

  15. Texas Teacher Evaluation & Support System (T-TESS) Appraiser Handbook

    Science.gov (United States)

    Texas Education Agency, 2016

    2016-01-01

    The Texas Education Agency's (TEA) approved instrument for evaluating teachers, the Professional Development and Appraisal System (PDAS), was the primary instrument used by 86 percent of local education agencies (LEAs) in the state and has been in place since 1997. In acknowledging the vital roles teachers play in student achievement, and based on…

  16. Evaluation methodology for fixed-site physical protection systems

    International Nuclear Information System (INIS)

    Bennett, H.A.; Olascoaga, M.T.

    1980-01-01

    A system performance evaluation methodology has been developed to aid the Nuclear Regulatory Commission (NRC) in the implementation of new regulations designed to upgrade the physical protection of nuclear fuel cycle facilities. The evaluation methodology, called Safeguards Upgrade Rule Evaluation (SURE), provides a means of explicitly incorporating measures for highly important and often difficult to quantify performance factors, e.g., installation, maintenance, training and proficiency levels, compatibility of components in subsystems, etc. This is achieved by aggregating responses to component and system questionaires through successive levels of a functional hierarchy developed for each primary performance capability specified in the regulations, 10 CFR 73.45. An overall measure of performance for each capability is the result of this aggregation process. This paper provides a descripton of SURE

  17. Cooperative Telerobotic Retrieval system Phase 1 technology evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, R.A.; Croft, K.M.

    1995-03-01

    This document describes the results from the Cooperative Telerobotic Retrieval demonstration and testing conducted at the Idaho National Engineering Laboratory during December 1994 and January 1995. The purpose of the demonstration was to ascertain the feasibility of the system for deploying tools both independently and cooperatively for supporting remote characterization and removal of buried waste in a safe manner and in compliance with all regulatory requirements. The procedures and goals of the demonstration were previously defined in the Cooperative Telerobotic Retrieval System Test Plan for Fiscal Year 1994, which served as a guideline for evaluating the system.

  18. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  19. Solar energy system economic evaluation: Fern Tunkhannock, Tunkhannock, Pennsylvania

    Science.gov (United States)

    1980-01-01

    The economic performance of an Operational Test Site (OTS) is described. The long term economic performance of the system at its installation site and extrapolation to four additional selected locations to demonstrate the viability of the design over a broad range of environmental and economic conditions is reported. Topics discussed are: system description, study approach, economic analysis and system optimization, and technical and economical results of analysis. Data for the economic analysis are generated through evaluation of the OTS. The simulation is based on the technical results of the seasonal report simulation. In addition localized and standard economic parameters are used for economic analysis.

  20. Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS)

    Energy Technology Data Exchange (ETDEWEB)

    Bland, Geoffrey [NASA Goddard Space Flight Center (GSFC), Greenbelt, MD (United States)

    2016-06-30

    The use of small unmanned aircraft systems (sUAS) with miniature sensor systems for atmospheric research is an important capability to develop. The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) project, lead by Dr. Gijs de Boer of the Cooperative Institute for Research in Environmental Sciences (CIRES- a partnership of NOAA and CU-Boulder), is a significant milestone in realizing this new potential. This project has clearly demonstrated that the concept of sUAS utilization is valid, and miniature instrumentation can be used to further our understanding of the atmospheric boundary layer in the arctic.

  1. Comparison and evaluation of flexible and stiff piping systems

    International Nuclear Information System (INIS)

    Hahn, W.; Tang, H.T.; Tang, Y.K.

    1983-01-01

    An experimental and numerical study was performed on a piping system, with various support configurations, to assess the difference in piping response for flexible and stiff piping systems. Questions have arisen concerning a basic design philosophy employed in present day piping designs. One basic question is, the reliability of a flexible piping system greater than that of a stiff piping system by virtue of the fact that a flexible system has fewer snubber supports. With fewer snubbers, the pipe is less susceptible to inadvertent thermal stresses introduced by snubber malfunction during normal operation. In addition to the technical issue, the matter of cost savings in flexible piping system design is a significant one. The costs associated with construction, in-service inspection and maintenance are all significantly reduced by reducing the number of snubber supports. The evaluation study, sponsored by the Electric Power Research Institute, was performed on a boiler feedwater line at Consolidated Edison's Indian Point Unit 1. In this study, the boiler feedwater line was tested and analyzed with two fundamentally different support systems. The first system was very flexible, employing rod and spring hangers, and represented the 'old' design philosophy. The pipe system was very flexible with this support system, due to the long pipe span lengths between supports and the fact that there was only one lateral support. This support did not provide much restraint since it was near an anchor. The second system employed strut and snubber supports and represented the 'modern' design philosophy. The pipe system was relatively stiff with this support system, primarily due to the increased number of supports, including lateral supports, thereby reducing the pipe span lengths between supports. The second support system was designed with removable supports to facilitate interchange of the supports with different support types (i.e., struts, mechanical snubbers and hydraulic

  2. The evaluation of set of criticality parameters using scale system

    International Nuclear Information System (INIS)

    Abe, Alfredo; Sanchez, Andrea; Yamaguchi, Mistuo

    2009-01-01

    In evaluating the criticality safety of the nuclear fuel facility, it is important to apply a consistent methodology, which consider every aspects concerning various types of criticality parameters. Usually, the critical parameters are compiled and arranged into handbooks, and these handbooks are based on experience with nuclear facilities, experimental data from criticality safety research facilities, and theoretical studies performed using numerical simulations. Most of criticality safety evaluation can be addressed using the criticality parameters data directly from handbook, but some critical parameters for a specific chemical mixtures and/or enrichment are not be available. Consequently, not available parameters has to be evaluated. This work present the methodology to evaluate a set of critical parameters using SCALE system for various types of mixtures present at nuclear fuel cycle facilities for two different level of enrichment, the results are verified in the independent calculation using MCNP Monte Carlo Code. (author)

  3. Tabletop exercise as a tool of evaluating physical protection system

    International Nuclear Information System (INIS)

    Matsuzawa, Reina

    2014-01-01

    Evaluation of designed and implemented physical protection system (PPS) is essential for ensuring the effectiveness of PPS. In Japan, nuclear facility operators, which are required to assess performance of PPS, have conducted performance test of PPS element and periodical trainings as well as annual PPS exercise with relevant agencies. In addition to these practical or field efforts, non-field tool for evaluating PPS effectiveness such as tabletop exercise (TTX) can be utilized as it is applied in the USA and other countries. This paper discusses the potential advantage of TTX as an evaluation tool of PPS effectiveness, looking at the characterizations of TTX in comparison to field evaluations, and potential cases where operator would get benefit from TTX especially. (author)

  4. Reliability evaluation of deregulated electric power systems for planning applications

    International Nuclear Information System (INIS)

    Ehsani, A.; Ranjbar, A.M.; Jafari, A.; Fotuhi-Firuzabad, M.

    2008-01-01

    In a deregulated electric power utility industry in which a competitive electricity market can influence system reliability, market risks cannot be ignored. This paper (1) proposes an analytical probabilistic model for reliability evaluation of competitive electricity markets and (2) develops a methodology for incorporating the market reliability problem into HLII reliability studies. A Markov state space diagram is employed to evaluate the market reliability. Since the market is a continuously operated system, the concept of absorbing states is applied to it in order to evaluate the reliability. The market states are identified by using market performance indices and the transition rates are calculated by using historical data. The key point in the proposed method is the concept that the reliability level of a restructured electric power system can be calculated using the availability of the composite power system (HLII) and the reliability of the electricity market. Two case studies are carried out over Roy Billinton Test System (RBTS) to illustrate interesting features of the proposed methodology

  5. Effectiveness evaluation of alternative fixed-site safeguard security systems

    International Nuclear Information System (INIS)

    Chapman, L.D.

    1976-01-01

    An evaluation of a fixed-site physical protection system must consider the interrelationships of barriers, alarms, on-site and off-site guards, and their effectiveness against a forcible adversary attack intent on creating an act of sabotage of theft. A computer model, Forcible Entry Safeguard Effectiveness Model (FESEM), was developed for the evaluation of alternative fixed-site protection systems. It was written in the GASP IV simulation language. A hypothetical fixed-state protection system is defined and relative evaluations from a cost-effectiveness point of view are presented in order to demonstrate how the model can be used. Trade-offs involving on-site and off-site response forces and response times, perimeter system alarms, barrier configurations, and varying levels of threat are analyzed. The computer model provides a framework for performing inexpensive experiments on fixed-site security systems, for testing alternative decisions, and for determining the relative cost effectiveness associated with these decision policies

  6. Evaluating a decision making system for cardiovascular dysautonomias diagnosis.

    Science.gov (United States)

    Idri, Ali; Kadi, Ilham

    2016-01-01

    Autonomic nervous system (ANS) is the part of the nervous system that is involved in homeostasis of the whole body functions. A malfunction in this system can lead to a cardiovascular dysautonomias. Hence, a set of dynamic tests are adopted in ANS units to diagnose and treat patients with cardiovascular dysautonomias. The purpose of this study is to develop and evaluate a decision tree based cardiovascular dysautonomias prediction system on a dataset collected from the ANS unit of the Moroccan university hospital Avicenne. We collected a dataset of 263 records from the ANS unit of the Avicenne hospital. This dataset was split into three subsets: training set (123 records), test set (55 records) and validation set (85 records). C4.5 decision tree algorithm was used in this study to develop the prediction system. Moreover, Java Enterprise Edition platform was used to implement a prototype of the developed system which was deployed in the Avicenne ANS unit so as to be clinically validated. The performance of the decision tree-based prediction system was evaluated by means of the error rate criterion. The error rates were measured for each classifier and have achieved an average value of 1.46, 2.24 and 0.89 % in training, test, and validation sets respectively. The results obtained were encouraging but further replicated studies are still needed to be performed in order to confirm the findings of this study.

  7. A novel reliability evaluation method for large engineering systems

    Directory of Open Access Journals (Sweden)

    Reda Farag

    2016-06-01

    Full Text Available A novel reliability evaluation method for large nonlinear engineering systems excited by dynamic loading applied in time domain is presented. For this class of problems, the performance functions are expected to be function of time and implicit in nature. Available first- or second-order reliability method (FORM/SORM will be challenging to estimate reliability of such systems. Because of its inefficiency, the classical Monte Carlo simulation (MCS method also cannot be used for large nonlinear dynamic systems. In the proposed approach, only tens instead of hundreds or thousands of deterministic evaluations at intelligently selected points are used to extract the reliability information. A hybrid approach, consisting of the stochastic finite element method (SFEM developed by the author and his research team using FORM, response surface method (RSM, an interpolation scheme, and advanced factorial schemes, is proposed. The method is clarified with the help of several numerical examples.

  8. Course Evaluation Systems for Open-ended Quality Enhancement

    DEFF Research Database (Denmark)

    Piihl, Jesper; Rasmussen, Jens Smed

    2013-01-01

    Quality in higher education is widely controlled through surveys asking students to evaluate teaching. However, control of quality does not necessarily lead to enhancement of quality. Drawing on accounting research and a case study, a measurement-based and open-ended quality control system...... emphasising quality enhancement is suggested. The case shows how interactive use of performance measurement can lead to more engaged and enabling dialogue amongst involved actors concerning quality enhancement, however institutionalised beliefs regarding course evaluation systems makes a change challenging....... The chapter suggests that open-ended measurement systems enabling stakeholders to take responsibility for quality enhancement is not so much a matter of technical design as a matter of an enabling style of use....

  9. Performance evaluation and design of flight vehicle control systems

    CERN Document Server

    Falangas, Eric T

    2015-01-01

    This book will help students, control engineers and flight dynamics analysts to model and conduct sophisticated and systemic analyses of early flight vehicle designs controlled with multiple types of effectors and to design and evaluate new vehicle concepts in terms of satisfying mission and performance goals. Performance Evaluation and Design of Flight Vehicle Control Systems begins by creating a dynamic model of a generic flight vehicle that includes a range of elements from airplanes and launch vehicles to re-entry vehicles and spacecraft. The models may include dynamic effects dealing with structural flexibility, as well as dynamic coupling between structures and actuators, propellant sloshing, and aeroelasticity, and they are typically used for control analysis and design. The book shows how to efficiently combine different types of effectors together, such as aero-surfaces, TVC, throttling engines and RCS, to operate as a system by developing a mixing logic atrix. Methods of trimming a vehicle controll...

  10. Evaluation of ISABELLE full cell ultra high vacuum system

    International Nuclear Information System (INIS)

    Foerster, C.L.; Briggs, J.; Chou, T.S.; Stattel, P.

    1980-01-01

    The ISABELLE Full Cell Vacuum System consisting of a 40 m long, by 8.8 cm diameter stainless steel tube pumped by seven pumping stations was assembled and processed for 10 -12 Torr operation. Evaluation and testing of the system and its sub-assemblies has been completed. Detail design of system components and the determination of the conditioning process was completed. The best procedure to rough pump, leak test, vacuum bake the system, condition pumps, degas gauges, turn on ion pumps and flash sublimation pumps was established. Pressures below 2 x 10 -11 Torr are now routinely achieved in normal operation of the Full Cell. This includes pump down after replacement of various components and pump down after back fill with moist unfiltered air. The techniques developed for the Full Cell will be used to build the ISABELLE Ultra High Vacuum System

  11. Solar energy system economic evaluation for Seeco Lincoln, Lincoln, Nebraska

    Science.gov (United States)

    1980-01-01

    The economic analysis of the solar energy system that was installed at Lincoln, Nebraska is developed for this and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over projected twenty year life: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  12. Solar energy system economic evaluation for Solaron Akron, Akron, Ohio

    Science.gov (United States)

    1980-01-01

    The economic analysis of the solar energy system that was installed at Akron, Ohio is developed for this and four other sites typical of a wide range of environmental and economic conditions. The analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results show that only in Albuquerque, New Mexico, where insolation is 1828 Btu/sq ft/day and the conventional energy cost is high, is this solar energy system marginally profitable.

  13. Evaluation of the reliability of a passive system

    International Nuclear Information System (INIS)

    Bianchi, F.; Burgazzi, L.; D'Auria, F.; Galassi, G.M.; Ricotti, M.E.; Oriani, L.

    2001-01-01

    A passive system should be theoretically more reliable than an active one. In fact its operation is independent by any external input or energy and is relied only upon natural physical laws (e.g., gravity, natural circulation, etc.) and/or 'intelligent' use of the energy inherently available in the system (e.g., chemical reaction, decay heat, etc.). Nevertheless the passive system may fail its mission as consequences of component failures, deviation of physical phenomena, boundary and/or initial conditions from the expectation. This document describes at first the methodology developed by ENEA, in collaboration of University of Pisa and Polytechnic of Milano, allowing the evaluation of the reliability for a passive system, which operation is based on moving working fluids (type B and C, cf. IAEA). It reports the results of an exercise performed on a system, which operation is based on Natural Circulation.(author)

  14. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  15. Applying the System Component and Operationally Relevant Evaluation (SCORE) Framework to Evaluate Advanced Military Technologies

    Science.gov (United States)

    2010-03-01

    and charac- terize the actions taken by the soldier (e.g., running, walking, climbing stairs ). Real-time image capture and exchange N The ability of...multimedia information sharing among soldiers in the field, two-way speech translation systems, and autonomous robotic platforms. Key words: Emerging...soldiers in the field, two-way speech translation systems, and autonomous robotic platforms. It has been the foundation for 10 technology evaluations

  16. Electronic clinical safety reporting system: a benefits evaluation.

    Science.gov (United States)

    Elliott, Pamela; Martin, Desmond; Neville, Doreen

    2014-06-11

    Eastern Health, a large health care organization in Newfoundland and Labrador (NL), started a staged implementation of an electronic occurrence reporting system (used interchangeably with "clinical safety reporting system") in 2008, completing Phase One in 2009. The electronic clinical safety reporting system (CSRS) was designed to replace a paper-based system. The CSRS involves reporting on occurrences such as falls, safety/security issues, medication errors, treatment and procedural mishaps, medical equipment malfunctions, and close calls. The electronic system was purchased from a vendor in the United Kingdom that had implemented the system in the United Kingdom and other places, such as British Columbia. The main objective of the new system was to improve the reporting process with the goal of improving clinical safety. The project was funded jointly by Eastern Health and Canada Health Infoway. The objectives of the evaluation were to: (1) assess the CSRS on achieving its stated objectives (particularly, the benefits realized and lessons learned), and (2) identify contributions, if any, that can be made to the emerging field of electronic clinical safety reporting. The evaluation involved mixed methods, including extensive stakeholder participation, pre/post comparative study design, and triangulation of data where possible. The data were collected from several sources, such as project documentation, occurrence reporting records, stakeholder workshops, surveys, focus groups, and key informant interviews. The findings provided evidence that frontline staff and managers support the CSRS, identifying both benefits and areas for improvement. Many benefits were realized, such as increases in the number of occurrences reported, in occurrences reported within 48 hours, in occurrences reported by staff other than registered nurses, in close calls reported, and improved timelines for notification. There was also user satisfaction with the tool regarding ease of use

  17. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    Science.gov (United States)

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  18. Satellite power system concept development and evaluation program system definition technical assessment report

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-01

    The results of the system definition studies conducted by NASA as a part of the Department of Energy/National Aeronautics and Space Administration SPS Concept Development and Evaluation Program are summarized. The purpose of the system definition efforts was to identify and define candidate SPS concepts and to evaluate the concepts in terms of technical and cost factors. Although the system definition efforts consisted primarily of evaluation and assessment of alternative technical approaches, a reference system was also defined to facilitate economic, environmental, and societal assessments by the Department of Energy. This reference system was designed to deliver 5 GW of electrical power to the utility grid. Topics covered include system definition; energy conversion and power management; power transmission and reception; structures, controls, and materials; construction and operations; and space transportation.

  19. An Evaluation System for the Online Training Programs in Meteorology and Hydrology

    Science.gov (United States)

    Wang, Yong; Zhi, Xiefei

    2009-01-01

    This paper studies the current evaluation system for the online training program in meteorology and hydrology. CIPP model that includes context evaluation, input evaluation, process evaluation and product evaluation differs from Kirkpatrick model including reactions evaluation, learning evaluation, transfer evaluation and results evaluation in…

  20. Evaluation System and Implementation Countermeasure of Automobile Green Maintenance

    Science.gov (United States)

    Zhang, Fei; Xie, Xinxin; Yan, Chaoyong

    2018-01-01

    Green maintenance research is in the beginning of our country, the work is being explored. Based on the existing research results at home and abroad, this paper learns and draws lessons from the experiences and lessons of foreign advanced countries and domestic advanced enterprises. In the face of the challenges brought by economic development and energy saving and emission reduction, this paper discusses the green maintenance theory and security system, And the research status of green maintenance content and system at home and abroad, through the deletion and selection of green maintenance index, through the AHP method to determine the green evaluation criteria, and the introduction of C equivalent evaluation system, the use of fuzzy synthesis Evaluation method to build a green maintenance evaluation model, and the actual validation, put forward the implementation of green maintenance feasibility programs and related security recommendations, vehicle maintenance enterprises to carry out green maintenance, improve business efficiency and reduce environmental management costs to provide theoretical basis. And to achieve effective reduction of environmental pollution, reduce maintenance costs of the target, a reasonable promotion of maintenance and environmental protection and sustainable development. Promote green maintenance from research to practice, from the laboratory to the maintenance of enterprises, from the pilot to the overall development and transformation.

  1. Towards an evaluation framework for Laboratory Information Systems.

    Science.gov (United States)

    Yusof, Maryati M; Arifin, Azila

    Laboratory testing and reporting are error-prone and redundant due to repeated, unnecessary requests and delayed or missed reactions to laboratory reports. Occurring errors may negatively affect the patient treatment process and clinical decision making. Evaluation on laboratory testing and Laboratory Information System (LIS) may explain the root cause to improve the testing process and enhance LIS in supporting the process. This paper discusses a new evaluation framework for LIS that encompasses the laboratory testing cycle and the socio-technical part of LIS. Literature review on discourses, dimensions and evaluation methods of laboratory testing and LIS. A critical appraisal of the Total Testing Process (TTP) and the human, organization, technology-fit factors (HOT-fit) evaluation frameworks was undertaken in order to identify error incident, its contributing factors and preventive action pertinent to laboratory testing process and LIS. A new evaluation framework for LIS using a comprehensive and socio-technical approach is outlined. Positive relationship between laboratory and clinical staff resulted in a smooth laboratory testing process, reduced errors and increased process efficiency whilst effective use of LIS streamlined the testing processes. The TTP-LIS framework could serve as an assessment as well as a problem-solving tool for the laboratory testing process and system. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  2. Safety Evaluation of Kartini Reactor Based on Instrumentation System Design

    International Nuclear Information System (INIS)

    Tjipta Suhaemi; Djen Djen Dj; Itjeu K; Johnny S; Setyono

    2003-01-01

    The safety of Kartini reactor has been evaluated based on instrumentation system aspect. The Kartini reactor is designed by BATAN. Design power of the reactor is 250 kW, but it is currently operated at 100 kW. Instrumentation and control system function is to monitor and control the reactor operation. Instrumentation and control system consists of safety system, start-up and automatic power control, and process information system. The linear power channel and logarithmic power channel are used for measuring power. There are 3 types of control rod for controlling the power, i.e. safety rod, shim rod, and regulating rod. The trip and interlock system are used for safety. There are instrumentation equipment used for measuring radiation exposure, flow rate, temperature and conductivity of fluid The system of Kartini reactor has been developed by introducing a process information system, start-up system, and automatic power control. It is concluded that the instrumentation of Kartini reactor has followed the requirement and standard of IAEA. (author)

  3. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  4. An evaluation of the management system verification pilot at Hanford

    International Nuclear Information System (INIS)

    Briggs, C.R.; Ramonas, L.; Westendorf, W.

    1998-01-01

    The Chemical Management System (CMS), currently under development at Hanford, was used as the ''test program'' for pilot testing the value added aspects of the Chemical Manufacturers Association's (CMA) Management Systems Verification (MSV) process. The MSV process, which was developed by CMA's member chemical companies specifically as a tool to assist in the continuous improvement of environment, safety and health (ESH) performance, represents a commercial sector ''best practice'' for evaluating ESH management systems. The primary purpose of Hanford's MSV Pilot was to evaluate the applicability and utility of the MSV process in the Department of Energy (DOE) environment. However, because the Integrated Safety Management System (ISMS) is the framework for ESH management at Hanford and at all DOE sites, the pilot specifically considered the MSV process in the context of a possible future adjunct to Integrated Safety Management System Verification (ISMSV) efforts at Hanford and elsewhere within the DOE complex. The pilot involved the conduct of two-hour interviews with four separate panels of individuals with functional responsibilities related to the CMS including the Department of Energy Richland Operations (DOE-RL), Fluor Daniel Hanford (FDH) and FDH's major subcontractors (MSCS). A semi-structured interview process was employed by the team of three ''verifiers'' who directed open-ended questions to the panels regarding the development, integration and effectiveness of management systems necessary to ensure the sustainability of the CMS effort. An ''MSV Pilot Effectiveness Survey'' also was completed by each panel participant immediately following the interview

  5. [Wavelength Selection in Hemolytic Evaluation Systems with Spectrophotometry Detection].

    Science.gov (United States)

    Zhang, Hong; Su, Baochang; Ye, Xunda; Luo, Man

    2016-04-01

    Spectrophotometry is a simple hemolytic evaluation method commonly used in new drugs,biomedical materials and blood products.It is for the quantitative analysis of the characteristic absorption peaks of hemoglobin.Therefore,it is essential to select the correct detection wavelength when the evaluation system has influences on the conformation of hemoglobin.Based on the study of changes in the characteristic peaks over time of the hemolysis supernatant in four systems,namely,cell culture medium,phosphate buffered saline(PBS),physiological saline and banked blood preservation solution,using continuous wavelength scanning,the selections of detection wavelength were proposed as follows.In the cell culture medium system,the wavelength of 415 nm should be selected within 4h;,near 408 nm should be selected within 4~72h.In PBS system,within 4h,541 nm,577nm or 415 nm should be selected;4~72h,541 nm,577nm or near 406 nm should be selected.In physiological saline system,within 4h,414 nm should be selected;4~72h,near 405 nm should be selected;within 12 h,541nm or 577 nm could also be selected.In banked blood preservation solution system,within 72 h,415nm,540 nm or 576 nm should be selected.

  6. Information Systems Evaluation: A Study in Hospital Organizations

    Directory of Open Access Journals (Sweden)

    Laís Coelho Ayala

    2012-06-01

    Full Text Available Given increasing demand for timely and accurate information to support decision making, hospitals, a particularly complex type of service organization, have increasingly resorted to a wide range of tools such as the Clinical Information Systems (CIS. However, research has shown that such systems do not always meet hospital managers’ needs, and assessment processes are necessary both before and after CIS implementation. Aiming to identify whether the CIS do meet hospital managers’ information needs and do fit in the specificities of such organizations, this paper reports on the assessment of four CIS based on the perspective of their users in four hospitals in the Metropolitan Region of Belo Horizonte, State of Minas Gerais, Brazil. The data was collected by means of semi-structured interviews and non-obtrusive observation. On the one hand, the result shows that the four organizations have difficulties in using their systems, such as accessibility problems, inadequate training and system underutilization. On the other hand, they also benefit from such systems, as they make processes faster and enable information control. One can say that the results from this research contribute to a better understanding of evaluating information systems in hospitals. Managers of such organizations can benefit from these results when seeking to evaluate and improve their information systens.

  7. Cross-system evaluation of clinical trial search engines.

    Science.gov (United States)

    Jiang, Silis Y; Weng, Chunhua

    2014-01-01

    Clinical trials are fundamental to the advancement of medicine but constantly face recruitment difficulties. Various clinical trial search engines have been designed to help health consumers identify trials for which they may be eligible. Unfortunately, knowledge of the usefulness and usability of their designs remains scarce. In this study, we used mixed methods, including time-motion analysis, think-aloud protocol, and survey, to evaluate five popular clinical trial search engines with 11 users. Differences in user preferences and time spent on each system were observed and correlated with user characteristics. In general, searching for applicable trials using these systems is a cognitively demanding task. Our results show that user perceptions of these systems are multifactorial. The survey indicated eTACTS being the generally preferred system, but this finding did not persist among all mixed methods. This study confirms the value of mixed-methods for a comprehensive system evaluation. Future system designers must be aware that different users groups expect different functionalities.

  8. A New Physical Protection System Design and Evaluation Process

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Heoksoon; Kim, Myungsu; Bae, Yeongkyoung; Na, Janghwan [KHNP-CRI, Daejeon (Korea, Republic of)

    2014-10-15

    International Atomic Energy Agency(IAEA) had established security-related department and has been strengthening security measures against possible sabotage. IAEA enforces the recommendations for the physical protection of NPPs in the INFCIRC/ 225/Rev.5 to the member states and U.S. NRC also enforces the similar requirements in 10 CFR 73.55. Thus, in order to let Korean NPPs meet the new requirements in INFCIRC/225/Rev.5 or U.S. NRC requirements, Korea nuclear licensee should develop or establish appropriate physical protection system (PPS) design methods for the physical protection of the operating NPPs and new NPPs. KHNP is doing the project of 'Development of APR1400 Physical Protection System Design (2012- 2015, KHNP/KAERI /KEPCO E-C)'. This paper describes overview of a physical protection system (PPS) design and evaluation for an advanced nuclear power plant. It found that a new physical protection system (PPS)design and evaluation. KHNP is doing the project of Physical Protection System design according to U.S. NRC requirements and IAEA requirements in INFCIRC /225 /Rev.5 and will complete by 7.31, 2015 for development of APR1400 Physical Protection System. After completing this project, the results of project are expected to apply new NPPs.

  9. The equity lens in the health care performance evaluation system.

    Science.gov (United States)

    Barsanti, Sara; Nuti, Sabina

    2014-01-01

    The main objective of this paper is to describe how indicators of the equity of access to health care according to socioeconomic conditions may be included in a performance evaluation system (PES) in the regional context level and in the planning and strategic control system of healthcare organisations. In particular, the paper investigates how the PES adopted, in the experience of the Tuscany region in Italy, indicators of vertical equity over time. Studies that testify inequality of access to health services often remain just a research output and are not used as targets and measurements in planning and control systems. After a brief introduction to the concept of horizontal and vertical equity in health care systems and equity measures in PES, the paper describes the 'equity process' by which selected health indicators declined by socioeconomic conditions were shared and used in the evaluation of health care institutions and in the CEOs' rewarding system, and subsequently analyses the initial results. Results on the maternal and child path and the chronicity care path not only show improvements in addressing health care inequalities, but also verify whether the health system responds appropriately to different population groups. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Performances of different digital mammography imaging systems: Evaluation and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)]. E-mail: giuseppina.bisogni@pi.infn.it; Bulajic, D. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); International Centre for Theoretical Physics, Trieste (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)

    2005-07-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems.

  11. Performances of different digital mammography imaging systems: Evaluation and comparison

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Bulajic, D.; Delogu, P.; Fantacci, M.E.; Novelli, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.

    2005-01-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems

  12. Usability evaluation of in-housed developed ERP system

    Science.gov (United States)

    Faisal, Chaudhry Muhammad Nadeem; Shakeel Faridi, Muhammad; Javed, Zahid

    2011-10-01

    Enterprise Resource Planning systems are the combination of different business IS (Information System) applications that are designed according to the organization requirements. Generally ERP systems are suffering from complex user interface issues. Recent research shows that there is a need for improvement concerning, the user interface from their perspectives. In order to design the software applications that are easy to use, memorize and apply to new problems, we must know the users philosophy and something about learning, reminiscence and problems solving. The Usability engineering is the only way to study the deeds of users while interacting with ERP (Enterprise Resource & Planning). This paper will focus on the users' experiences view of financial module in ERP system. The HCI research method, explicitly survey questionnaire method was adopted to gather users understanding in order to evaluate the selected modules for in-housed ERP system. The study involved group of users from two industries, the results can not be generalized as a whole. The study was first time successfully applied Usability evaluation on in-housed ERP in local industry (Masood Textile Mills, Interloop Ltd) in Pakistan. The results may hopefully opened-up an area of research and methodology that could provide considerable further benefits to Industry in developments of Industrial information systems.

  13. Scopus: A system for the evaluation of scientific journals

    Science.gov (United States)

    Guz, A. N.; Rushchitsky, J. J.

    2009-04-01

    The paper discusses the evaluation of scientific journals based on the Scopus database, information tools, and criteria. The SJR (SCImago Journal Rank) as the main criterion used by Scopus to evaluate scientific journals is considered. The Scopus and ISI systems are compared using information on the journal Prikladnaya Mekhanika ( International Applied Mechanics), a number of world-known journals on mechanics, and some journals on natural sciences issued by the National Academy of Sciences of Ukraine. Some comments and proposals are formulated. This paper may be considered as a follow up on papers published in Prikladnaya Mekhanika ( International Applied Mechanics) in 2005-2009

  14. Risk evaluation system for facility safeguards and security planning

    International Nuclear Information System (INIS)

    Udell, C.J.; Carlson, R.L.

    1987-01-01

    The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planing assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily

  15. Risk evaluation system for facility safeguards and security planning

    International Nuclear Information System (INIS)

    Udell, C.J.; Carlson, R.L.

    1987-01-01

    The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planning assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily

  16. Evaluation of health care system reform in Hubei Province, China.

    Science.gov (United States)

    Sang, Shuping; Wang, Zhenkun; Yu, Chuanhua

    2014-02-21

    This study established a set of indicators for and evaluated the effects of health care system reform in Hubei Province (China) from 2009 to 2011 with the purpose of providing guidance to policy-makers regarding health care system reform. The resulting indicators are based on the "Result Chain" logic model and include the following four domains: Inputs and Processes, Outputs, Outcomes and Impact. Health care system reform was evaluated using the weighted TOPSIS and weighted Rank Sum Ratio methods. Ultimately, the study established a set of indicators including four grade-1 indicators, 16 grade-2 indicators and 76 grade-3 indicators. The effects of the reforms increased year by year from 2009 to 2011 in Hubei Province. The health status of urban and rural populations and the accessibility, equity and quality of health services in Hubei Province were improved after the reforms. This sub-national case can be considered an example of a useful approach to the evaluation of the effects of health care system reform, one that could potentially be applied in other provinces or nationally.

  17. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional-integral, proportio......This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional......-integral, proportional-resonant, and deadbeat (DB) controllers. Additionally, an improved DB controller robust against grid impedance variation is also presented. Since the paper discusses the implementation of these controllers for grid-connected applications, their evaluation is made in three operating conditions....... First, in steady-state conditions, the contribution of controllers to the total harmonic distortion of the grid current is pursued. Further on, the behavior of controllers in the case of transient conditions like input power variations and grid voltage faults is also examined. Experimental results...

  18. Evaluation of Supply Chain Management Systems Used in Civil Engineering

    Science.gov (United States)

    Tomczak, Michał; Rzepecki, Łukasz

    2017-10-01

    One of the most important factors which have an effect on the cost and time of the building process is the organization of physical resources and the information flow structure. Depending on how effective this system is, a building project may end with a success or a failure. Because of many conditions of the construction executing and different needs of the contractors, there are different Supply Chain Management (SCM) systems connected with supplying construction projects: single-stage, multi-stage or combined. The article presents a comparative analysis of construction SCM systems based on a modified fuzzy AHP. The modification of this method is based on the use of interval type-2 fuzzy sets to aggregate evaluation according to the idea proposed by Mikhailov. The use of such a model of group preferences of decision-makers, makes it possible to take into consideration both the linguistic imprecision of an evaluation and the small number of experts. The weight values of specific criteria and the final scale vector of considered variants are obtained during the analysis. This may give a recommendation to general contractors in construction projects about which evaluation criteria and supply systems are preferred.

  19. Gamma- scintigraphy in the evaluation of drug delivery systems

    International Nuclear Information System (INIS)

    Shahhosseini, S.; Beiki, D.; Eftekhari, M.

    2003-01-01

    Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical delivery systems, particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate radionuclide such as technetium-99m or indium-111 into the formulation or by addition of a non- radioactive isotope such as samarium-152 followed by neutron activation of the final product. Drug delivery systems can be tested in vitro using various techniques like dissolution rate. Since in vitro testing methods are not predictive of in vivo results, such systems should be evaluated in vivo using animal models, especially oral dosage forms. Altered gastrointestinal transit due to individual variation, physiologic factors, or the presence of food may influence bioavailability. Distribution or drug release may be premature or delayed in vivo. Similarly, altered deposition or clearance from other routes of administration such as nasal, ocular, or inhalation may explain drug absorption anomalies. Therefore, there is a growing tendency for new drug delivery systems to be tested, whenever possible, in human subjects in a so called phase 1 clinical evaluation. Gamma- scintigraphy combined with knowledge of physiological and dosage from design can help to identify some of these variables. the resulting insight can be used to accelerate the formulation development process and to ensure success in early clinical trials

  20. A multi-method approach to evaluate health information systems.

    Science.gov (United States)

    Yu, Ping

    2010-01-01

    Systematic evaluation of the introduction and impact of health information systems (HIS) is a challenging task. As the implementation is a dynamic process, with diverse issues emerge at various stages of system introduction, it is challenge to weigh the contribution of various factors and differentiate the critical ones. A conceptual framework will be helpful in guiding the evaluation effort; otherwise data collection may not be comprehensive and accurate. This may again lead to inadequate interpretation of the phenomena under study. Based on comprehensive literature research and own practice of evaluating health information systems, the author proposes a multimethod approach that incorporates both quantitative and qualitative measurement and centered around DeLone and McLean Information System Success Model. This approach aims to quantify the performance of HIS and its impact, and provide comprehensive and accurate explanations about the casual relationships of the different factors. This approach will provide decision makers with accurate and actionable information for improving the performance of the introduced HIS.

  1. Sustainable Deforestation Evaluation Model and System Dynamics Analysis

    Science.gov (United States)

    Feng, Huirong; Lim, C. W.; Chen, Liqun; Zhou, Xinnian; Zhou, Chengjun; Lin, Yi

    2014-01-01

    The current study used the improved fuzzy analytic hierarchy process to construct a sustainable deforestation development evaluation system and evaluation model, which has refined a diversified system to evaluate the theory of sustainable deforestation development. Leveraging the visual image of the system dynamics causal and power flow diagram, we illustrated here that sustainable forestry development is a complex system that encompasses the interaction and dynamic development of ecology, economy, and society and has reflected the time dynamic effect of sustainable forestry development from the three combined effects. We compared experimental programs to prove the direct and indirect impacts of the ecological, economic, and social effects of the corresponding deforest techniques and fully reflected the importance of developing scientific and rational ecological harvesting and transportation technologies. Experimental and theoretical results illustrated that light cableway skidding is an ecoskidding method that is beneficial for the sustainable development of resources, the environment, the economy, and society and forecasted the broad potential applications of light cableway skidding in timber production technology. Furthermore, we discussed the sustainable development countermeasures of forest ecosystems from the aspects of causality, interaction, and harmony. PMID:25254225

  2. Sustainable deforestation evaluation model and system dynamics analysis.

    Science.gov (United States)

    Feng, Huirong; Lim, C W; Chen, Liqun; Zhou, Xinnian; Zhou, Chengjun; Lin, Yi

    2014-01-01

    The current study used the improved fuzzy analytic hierarchy process to construct a sustainable deforestation development evaluation system and evaluation model, which has refined a diversified system to evaluate the theory of sustainable deforestation development. Leveraging the visual image of the system dynamics causal and power flow diagram, we illustrated here that sustainable forestry development is a complex system that encompasses the interaction and dynamic development of ecology, economy, and society and has reflected the time dynamic effect of sustainable forestry development from the three combined effects. We compared experimental programs to prove the direct and indirect impacts of the ecological, economic, and social effects of the corresponding deforest techniques and fully reflected the importance of developing scientific and rational ecological harvesting and transportation technologies. Experimental and theoretical results illustrated that light cableway skidding is an ecoskidding method that is beneficial for the sustainable development of resources, the environment, the economy, and society and forecasted the broad potential applications of light cableway skidding in timber production technology. Furthermore, we discussed the sustainable development countermeasures of forest ecosystems from the aspects of causality, interaction, and harmony.

  3. Sustainable Deforestation Evaluation Model and System Dynamics Analysis

    Directory of Open Access Journals (Sweden)

    Huirong Feng

    2014-01-01

    Full Text Available The current study used the improved fuzzy analytic hierarchy process to construct a sustainable deforestation development evaluation system and evaluation model, which has refined a diversified system to evaluate the theory of sustainable deforestation development. Leveraging the visual image of the system dynamics causal and power flow diagram, we illustrated here that sustainable forestry development is a complex system that encompasses the interaction and dynamic development of ecology, economy, and society and has reflected the time dynamic effect of sustainable forestry development from the three combined effects. We compared experimental programs to prove the direct and indirect impacts of the ecological, economic, and social effects of the corresponding deforest techniques and fully reflected the importance of developing scientific and rational ecological harvesting and transportation technologies. Experimental and theoretical results illustrated that light cableway skidding is an ecoskidding method that is beneficial for the sustainable development of resources, the environment, the economy, and society and forecasted the broad potential applications of light cableway skidding in timber production technology. Furthermore, we discussed the sustainable development countermeasures of forest ecosystems from the aspects of causality, interaction, and harmony.

  4. Transgenic Arabidopsis Gene Expression System

    Science.gov (United States)

    Ferl, Robert; Paul, Anna-Lisa

    2009-01-01

    The Transgenic Arabidopsis Gene Expression System (TAGES) investigation is one in a pair of investigations that use the Advanced Biological Research System (ABRS) facility. TAGES uses Arabidopsis thaliana, thale cress, with sensor promoter-reporter gene constructs that render the plants as biomonitors (an organism used to determine the quality of the surrounding environment) of their environment using real-time nondestructive Green Fluorescent Protein (GFP) imagery and traditional postflight analyses.

  5. Shuttle orbiter Ku-band radar/communications system design evaluation. Deliverable test equipment evaluation

    Science.gov (United States)

    Maronde, R. G.

    1980-07-01

    The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.

  6. Some important issues in evaluating the availability of passive systems

    International Nuclear Information System (INIS)

    Kafka, P.; Kelemen, I.; Krzykacz, B.

    1993-01-01

    In some countries new reactor concepts based on a broader use of passive safety features are under development. The term 'passive' as used here refers to systems which rely heavily on natural heat transfer process such as natural circulation to perform their function rather than on decidedly 'active' components like pumps. The paper deals with important issues in evaluating the availability of passive systems, e.g. the assessment of the active components, the assessment of passive components and structures and the probabilistic assessment of the physical function of the natural processes. Based on an outlined assessment process for the entire system and on an exercised simulation process for the assessment of passive components e.g. pipes insights and important issues are presented. A follow-up study will refine and expand the concept to a full scope assessment procedure of passive systems. (author)

  7. Fatigue evaluation of piping systems with limited vibration test data

    International Nuclear Information System (INIS)

    Huang, S.N.

    1990-11-01

    The safety-related piping in a nuclear power plant may be subjected to pump- or fluid-induced vibrations that, in general, affect only local areas of the piping systems. Pump- or fluid-induced vibrations typically are characterized by low levels of amplitudes and a high number of cycles over the lifetime of plant operation. Thus, the resulting fatigue damage to the piping systems could be an important safety concern. In general, tests and/or analyses are used to evaluate and qualify the piping systems. Test data, however, may be limited because of lack of instrumentation in critical piping locations and/or because of difficulty in obtaining data in inaccessible areas. This paper describes and summarizes a method to use limited pipe vibration test data, along with analytical harmonic response results from finite-element analyses, to assess the fatigue damage of nuclear power plant safety-related piping systems. 5 refs., 2 figs., 11 tabs

  8. Use of an operational model evaluation system for model intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Foster, K. T., LLNL

    1998-03-01

    The Atmospheric Release Advisory Capability (ARAC) is a centralized emergency response system used to assess the impact from atmospheric releases of hazardous materials. As part of an on- going development program, new three-dimensional diagnostic windfield and Lagrangian particle dispersion models will soon replace ARAC`s current operational windfield and dispersion codes. A prototype model performance evaluation system has been implemented to facilitate the study of the capabilities and performance of early development versions of these new models relative to ARAC`s current operational codes. This system provides tools for both objective statistical analysis using common performance measures and for more subjective visualization of the temporal and spatial relationships of model results relative to field measurements. Supporting this system is a database of processed field experiment data (source terms and meteorological and tracer measurements) from over 100 individual tracer releases.

  9. Solar energy system economic evaluation: Contemporary Newman, Georgia

    Science.gov (United States)

    1980-01-01

    An economic evaluation of performance of the solar energy system (based on life cycle costs versus energy savings) for five cities considered to be representative of a broad range of environmental and economic conditions in the United States is discussed. The considered life cycle costs are: hardware, installation, maintenance, and operating costs for the solar unique components of the total system. The total system takes into consideration long term average environmental conditions, loads, fuel costs, and other economic factors applicable in each of five cities. Selection criteria are based on availability of long term weather data, heating degree days, cold water supply temperature, solar insolation, utility rates, market potential, and type of solar system.

  10. Designing and evaluating risk-based surveillance systems

    DEFF Research Database (Denmark)

    Willeberg, Preben; Nielsen, Liza Rosenbaum; Salman, Mo

    2012-01-01

    Risk-based surveillance systems reveal occurrence of disease or infection in a sample of population units, which are selected on the basis of risk factors for the condition under study. The purpose of such systems for supporting practical animal disease policy formulations and management decisions...... with prudent use of resources while maintaining acceptable system performance. High-risk category units are selected for testing by identification of the presence of specific high-risk factor(s), while disregarding other factors that might also influence the risk. On this basis we argue that the most...... applicable risk estimate for use in designing and evaluating a risk-based surveillance system would be a crude (unadjusted) relative risk, odds ratio or apparent prevalence. Risk estimates found in the published literature, however, are often the results of multivariable analyses implicitly adjusting...

  11. Performance evaluation of various cryogenic energy storage systems

    International Nuclear Information System (INIS)

    Abdo, Rodrigo F.; Pedro, Hugo T.C.; Koury, Ricardo N.N.; Machado, Luiz; Coimbra, Carlos F.M.; Porto, Matheus P.

    2015-01-01

    This work compares various CES (cryogenic energy storage) systems as possible candidates to store energy from renewable sources. Mitigating solar and wind power variability and its direct effect on local grid stability are already a substantial technological bottleneck for increasing market penetration of these technologies. In this context, CES systems represent low-cost solutions for variability that can be used to set critical power ramp rates. We investigate the different thermodynamic and engineering constraints that affect the design of CES systems, presenting theoretical simulations, indicating that optimization is also needed to improve the cryogenic plant performance. - Highlights: • We assessed the performance of cryogenic energy storage systems. • We re-evaluated the Linde–Hampson cycle proposed by Chen. • We proposed the Claude and Collins cycles as alternatives for the Linde–Hampson cycle. • We concluded that Claude cycle is the best alternative for the simulated conditions.

  12. Evaluating Complex Healthcare Systems: A Critique of Four Approaches

    Directory of Open Access Journals (Sweden)

    Heather Boon

    2007-01-01

    Full Text Available The purpose of this paper is to bring clarity to the emerging conceptual and methodological literature that focuses on understanding and evaluating complex or ‘whole’ systems of healthcare. An international working group reviewed literature from interdisciplinary or interprofessional groups describing approaches to the evaluation of complex systems of healthcare. The following four key approaches were identified: a framework from the MRC (UK, whole systems research, whole medical systems research described by NCCAM (USA and a model from NAFKAM (Norway. Main areas of congruence include acknowledgment of the inherent complexity of many healthcare interventions and the need to find new ways to evaluate these; the need to describe and understand the components of complex interventions in context (as they are actually practiced; the necessity of using mixed methods including randomized clinical trials (RCTs (explanatory and pragmatic and qualitative approaches; the perceived benefits of a multidisciplinary team approach to research; and the understanding that methodological developments in this field can be applied to both complementary and alternative medicine (CAM as well as conventional therapies. In contrast, the approaches differ in the following ways: terminology used, the extent to which the approach attempts to be applicable to both CAM and conventional medical interventions; the prioritization of research questions (in order of what should be done first especially with respect to how the ‘definitive’ RCT fits into the process of assessing complex healthcare systems; and the need for a staged approach. There appears to be a growing international understanding of the need for a new perspective on assessing complex healthcare systems.

  13. Use of the Long Duration Exposure Facility's thermal measurement system for the verification of thermal models

    Science.gov (United States)

    Berrios, William M.

    1992-01-01

    The Long Duration Exposure Facility (LDEF) postflight thermal model predicted temperatures were matched to flight temperature data recorded by the Thermal Measurement System (THERM), LDEF experiment P0003. Flight temperatures, recorded at intervals of approximately 112 minutes for the first 390 days of LDEF's 2105 day mission were compared with predictions using the thermal mathematical model (TMM). This model was unverified prior to flight. The postflight analysis has reduced the thermal model uncertainty at the temperature sensor locations from +/- 40 F to +/- 18 F. The improved temperature predictions will be used by the LDEF's principal investigators to calculate improved flight temperatures experienced by 57 experiments located on 86 trays of the facility.

  14. Power Distribution System Planning Evaluation by a Fuzzy Multi-Criteria Group Decision Support System

    Directory of Open Access Journals (Sweden)

    Tiefeng Zhang

    2010-10-01

    Full Text Available The evaluation of solutions is an important phase in power distribution system planning (PDSP which allows issues such as quality of supply, cost, social service and environmental implications to be considered and usually involves the judgments of a group of experts. The planning problem is thus suitable for the multi-criteria group decision-making (MCGDM method. The evaluation process and evaluation criteria often involve uncertainties incorporated in quantitative analysis with crisp values and qualitative judgments with linguistic terms; therefore, fuzzy sets techniques are applied in this study. This paper proposes a fuzzy multi-criteria group decision-making (FMCGDM method for PDSP evaluation and applies a fuzzy multi-criteria group decision support system (FMCGDSS to support the evaluation task. We introduce a PDSP evaluation model, which has evaluation criteria within three levels, based on the characteristics of a power distribution system. A case-based example is performed on a test distribution network and demonstrates how all the problems in a PDSP evaluation are addressed using FMCGDSS. The results are acceptable to expert evaluators.

  15. Evaluation of automatic exposure control systems in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Reina, Thamiris Rosado

    2014-07-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  16. Evaluation of automatic exposure control systems in computed tomography

    International Nuclear Information System (INIS)

    Reina, Thamiris Rosado

    2014-01-01

    The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AECsystem. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without

  17. Design and Evaluation of Microemulsion Gel System of Nadifloxacin

    Science.gov (United States)

    Shinde, Ujwala; Pokharkar, Sharda; Modani, Sheela

    2012-01-01

    Topical microemulsion systems for the antiacne agent, nadifloxacin were designed and developed to overcome the problems associated with the cutaneous delivery due to poor water solubility. The solubility of nadifloxacin in oils, surfactants and cosurfactants was evaluated to screen the components of the microemulsion. Various surfactants and cosurfactants were screened for their ability to emulsify the selected oily phase. The pseudoternary diagrams were constructed to identify the area of microemulsion existence. The influence of km (surfactant/cosurfactant) ratio on the microemulsion existence region was determined and optimum systems were designed. The systems were assessed for drug-loading efficiency and characterised for optical birefringence, pH and refractive index, robustness to dilution, globule size, drug content and thermodynamic stability. Optimised microemulsion systems were formulated into gel form and evaluated for viscosity, spreadability, drug content, ex vivo skin permeation and antibacterial activity. The maximum solubility of nadifloxacin in the microemulsion system was found to be 0.25%. The nadifloxacin microemulsions had a small and uniform globule size (67.3-121.23 nm). The stability results revealed that all formulations showed a stable globule size and the polydispersity index under stress conditions. Incorporation of nadifloxacin in microemulsion gel increased the ex vivo skin permeation and antibacterial activity when compared to marketed cream. PMID:23439454

  18. Thermoeconomic evaluation of air conditioning system with chilled water storage

    International Nuclear Information System (INIS)

    Lin, Hu; Li, Xin-hong; Cheng, Peng-sheng; Xu, Bu-gong

    2014-01-01

    Highlights: • A new thermoeconomic evaluation methodology has been presented. • The relationship between thermodynamic and economic performances has been revealed. • A key point for thermal storage technology further application is discovered. • A system has been analyzed via the new method and EUD method. - Abstract: As a good load shifting technology for power grid, chilled energy storage has been paid more and more attention, but it always consumes more energy than traditional air conditioning system, and the performance analysis is mostly from the viewpoint of peak-valley power price to get cost saving. The paper presents a thermoeconomic evaluation methodology for the system with chilled energy storage, by which thermodynamic performance influence on cost saving has been revealed. And a system with chilled storage has been analyzed, which can save more than 15% of power cost with no energy consumption increment, and just certain difference between peak and valley power prices can make the technology for good economic application. The results show that difference between peak and valley power prices is not the only factor on economic performance, thermodynamic performance of the storage system is the more important factor, and too big price difference is a barrier for its application, instead of for more cost saving. All of these give a new direction for thermal storage technology application

  19. Maintainability design and evaluation of mechanical systems based on tribology

    International Nuclear Information System (INIS)

    Wani, M.F.; Gandhi, O.P.

    2002-01-01

    Maintainability of mechanical systems based on tribology is suggested and evaluated in this paper. Tribo-features of mechanical systems, which characterise maintainability are identified and are modelled in terms of tribo-maintainability digraph. The nodes in the digraph represent the tribo-features and edges represent the degree of influence among the features. A matrix, one to one representation of the digraph, is defined to develop system maintainability expression (SPF-t) based on the tribology. It is also useful in comparing the various design alternatives from tribo-maintainability point of view. Maintainability is evaluated from the tribo-maintainability index, obtained from SPF-t (i.e. permanent of the matrix) by substituting the numerical values of the features and their interdependence. A higher value of the index implies better maintainability of the systems. The proposed methodology also guides designers in enhancing the maintainability of a system by appropriately incorporating tribo-features. An example to illustrate the methodology is also presented

  20. Integral evaluation of energy supply systems at mountain refuges

    Energy Technology Data Exchange (ETDEWEB)

    Aschauer, C. [Univ. of Natural Resources and Applied Life Sciences, Vienna (Austria). Inst. for Chemical and Energy Engineering; Steinbacher, G. [Steinbacher and Steinbacher Civil Engineering Inc. (Austria); Weber, P. [DAV-Deutscher Alpenverein e.V. (Germany). Bundesgeschaeftsstelle; Deubler, Hubert

    2010-07-01

    Most of the mountain refuges scattered over the Alps (more than 1500) are not connected to public infrastructure, requiring decentralized supply and disposal and are therefore called island systems. The increasing number of guests goes along with a higher demand for comport and thus puts pressure on available resources. There are numerous challenges like remoteness, transport, low temperatures, seasonal operation and climate change to be faced. Furthermore, the supply and disposal system of an alpine hut has to merge different interests of the alpine associations, refuge operators, legal authorities and the alpine tourists. Therefore the respective infracstructure has to be managed as an overall-self-contained system. Energy supply is the central issue showing complex interaction with water supply, wastewater treatment and waste disposal. Many problems according to planning, decision-making, construction and operation concerning alpine infrastructure are reported. However detailed information on experiences made in these fields is missing at an international level so far. To correct this lack of data, the German Alpine Association (DAV) initiated the project ''Integral Evaluation of Supply and Disposal Systems of Mountain Refuges, IEVEBS'' in 2006, inviting all stakeholders (Alpine Associations, Legal Authorities, Planners, and Researchers) to participate. Additionally to the final project report which contains a detailed description and evaluation of the supply systems, guidelines will be elaborated in 2010 for planning, implementation and operation, all applicable at an international level. (orig.)

  1. Advanced methods in evaluation of thermal power systems effectiveness

    International Nuclear Information System (INIS)

    Barnak, N.; Jakubcek, P.; Zadrazil, J.

    1993-01-01

    The universal method for thermodynamic systems process irreversibility evaluation based on exergetic approach is elaborated in this article. The method uses the basic property of exergy as extensive state parameter -additivity. Division of the system onto some hierarchic levels is considered and relation between exergetic system characteristics and its parts is defined. There are system structure coefficients in common form expressed article they are analysed. The criteria for technical and economical optimization of the system using expressed structure coefficients are defined. In the article, there are common approaches defined for the method application in the area of nuclear power plant secondary circuits and the method is used for nuclear power plant WWER-1000 secondary circuit analysis. For this, individual exergetic characteristics of secondary circuit and its parts are expressed and some of secondary circuit parameters are optimized. Proposals for practical realisation of the results are stated in the conclusions of the article, mainly in the area of computerized evaluation of technical and economical parameters of nuclear power plant and effectiveness of its operation

  2. Integrated Evaluation of Closed Loop Air Revitalization System Components

    Science.gov (United States)

    Murdock, K.

    2010-01-01

    NASA s vision and mission statements include an emphasis on human exploration of space, which requires environmental control and life support technologies. This Contractor Report (CR) describes the development and evaluation of an Air Revitalization System, modeling and simulation of the components, and integrated hardware testing with the goal of better understanding the inherent capabilities and limitations of this closed loop system. Major components integrated and tested included a 4-Bed Modular Sieve, Mechanical Compressor Engineering Development Unit, Temperature Swing Adsorption Compressor, and a Sabatier Engineering and Development Unit. The requisite methodolgy and technical results are contained in this CR.

  3. A thermodynamic evaluation of the Ti-Mo-C system

    International Nuclear Information System (INIS)

    Shim, J.H.; Oh, C.S.; Lee, D.N.

    1996-01-01

    A thermodynamic assessment of the Ti-Mo-C system has been made, employing a two-sublattice regular solution model for the solid solution and carbide phases and an ordinary subregular solution model for the liquid phase. A set of thermodynamic parameters describing the Gibbs energy of each individual phase in the Ti-Mo-C as well as the Ti-Mo systems was evaluated from thermochemical and phase equilibria information available in the literature through a computer-aided optimization procedure called the CALPHAD method. The comparison between the calculated and experimental results was made and practically important phase diagrams are also presented

  4. Technical Evaluation Report 5: Classification of DE Delivery Systems

    Directory of Open Access Journals (Sweden)

    Diane Belyk

    2002-01-01

    Full Text Available For their optimal use in distance education (DE, online educational applications need to be integrated within a comprehensive course management system (CMS. Such systems are server-based software that supports the development, delivery, administration, and evaluation of online learning environments. The selection of an appropriate CMS should be considered from the multiple perspectives of the student, the course developer, the course instructor/ tutor, the technical support staff, and the DE institution’s administration. The current evaluation of CMS packages was conducted by a team of individuals with experience and contacts in relation to each of these DE user types. The report compares a series of CMS packages in terms of their range of features, and in relation to their satisfaction of international online education standards.

  5. Performance Evaluation of a Biometric System Based on Acoustic Images

    Science.gov (United States)

    Izquierdo-Fuente, Alberto; del Val, Lara; Jiménez, María I.; Villacorta, Juan J.

    2011-01-01

    An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side). Two Uniform Linear Arrays (ULA) with 15 λ/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR)/False Non-Match Rate (FNMR) parameters and the Receiver Operating Characteristic (ROC) curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications. PMID:22163708

  6. Performance Evaluation of a Biometric System Based on Acoustic Images

    Directory of Open Access Journals (Sweden)

    Juan J. Villacorta

    2011-10-01

    Full Text Available An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side. Two Uniform Linear Arrays (ULA with 15 l/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR/False Non-Match Rate (FNMR parameters and the Receiver Operating Characteristic (ROC curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications.

  7. Performance evaluation of photovoltaic systems on Kuwaiti schools’ rooftop

    International Nuclear Information System (INIS)

    Al-Otaibi, A.; Al-Qattan, A.; Fairouz, F.; Al-Mulla, A.

    2015-01-01

    Highlights: • Evaluation of rooftop PV installations at 2 Kuwaiti schools was carried out. • Lack of real plants data in the region and specifically Kuwait motivated the work. • Automated cleaning system allowed for minimization of soiling loss. • The average PV system performance was greater than 76%. • Schools show high potential for rooftop installations. - Abstract: Photovoltaic (PV) is a high-potential renewable energy technology for Kuwait to pursue due to high daily irradiation, and has garnered local attention in recent years due to the growing energy demand and concerns over climate change. As yet, no data are available regarding the actual performance of PV systems in Kuwait’s harsh environment. This paper presents a 12-month-long performance evaluation of the first 85.05 kW p and 21.6 kW p copper indium gallium selenide (CIGS) thin film, grid-connected PV systems on the rooftops of two schools. The schools’ monthly energy consumption and PV generation profiles, the actual performance of the PV plants, the effectiveness of automated cleaning systems on the power output, and the benefits of PV implementation in schools were analyzed and evaluated. Data analysis was applied to filter and normalize the data in order to identify the actual performance parameters. The findings of the study, based on solar irradiation collected, the performance of the module technology and the effectiveness of the automated cleaning systems, show that the performance ratio was maintained between 0.74 and 0.85. Furthermore, the minimum monthly energy yield of the PV systems was about 104 kW h/kW p . The annual average daily final yields of the PV systems in this study were 4.5 kW h/kW p /day. The results provided insight into the performance of CIGS grid-connected PV systems in Kuwait, and those data will be beneficial to the PV research community worldwide. School buildings, particularly for the rooftops, are a unique and important asset for urban PV system

  8. Evaluation of an automated karyotyping system for chromosome aberration analysis

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1987-01-01

    Chromosome aberration analysis is a promising complement to conventional radiation dosimetry, particularly in the complex radiation fields encountered in the space environment. The capabilities of a recently developed automated karyotyping system were evaluated both to determine current capabilities and limitations and to suggest areas where future development should be emphasized. Cells exposed to radiometric chemicals and to photon and particulate radiation were evaluated by manual inspection and by automated karyotyping. It was demonstrated that the evaluated programs were appropriate for image digitization, storage, and transmission. However, automated and semi-automated scoring techniques must be advanced significantly if in-flight chromosome aberration analysis is to be practical. A degree of artificial intelligence may be necessary to realize this goal

  9. Digital integrated protection system: Quantitative methods for dependability evaluation

    International Nuclear Information System (INIS)

    Krotoff, H.; Benski, C.

    1986-01-01

    The inclusion of programmed digital techniques in the SPIN system provides the used with the capability of performing sophisticated processing operations. However, it causes the quantitative evaluation of the overall failure probabilities to become somewhat more intricate by reason that: A single component may be involved in several functions; Self-tests may readily be incorporated for the purpose of monitoring the dependable operation of the equipment at all times. This paper describes the methods as implemented by MERLIN GERIN for the purpose of evaluating: The probabilities for the protective actions not to be initiated (dangerous failures); The probabilities for such protective actions to be initiated accidentally. Although the communication is focused on the programmed portion of the SPIN (UAIP) it will also deal with the evaluation performed within the scope of study works that do not exclusively cover the UAIPs

  10. OWL2 benchmarking for the evaluation of knowledge based systems.

    Directory of Open Access Journals (Sweden)

    Sher Afgun Khan

    Full Text Available OWL2 semantics are becoming increasingly popular for the real domain applications like Gene engineering and health MIS. The present work identifies the research gap that negligible attention has been paid to the performance evaluation of Knowledge Base Systems (KBS using OWL2 semantics. To fulfil this identified research gap, an OWL2 benchmark for the evaluation of KBS is proposed. The proposed benchmark addresses the foundational blocks of an ontology benchmark i.e. data schema, workload and performance metrics. The proposed benchmark is tested on memory based, file based, relational database and graph based KBS for performance and scalability measures. The results show that the proposed benchmark is able to evaluate the behaviour of different state of the art KBS on OWL2 semantics. On the basis of the results, the end users (i.e. domain expert would be able to select a suitable KBS appropriate for his domain.

  11. System Life Cycle Evaluation(SM) (SLiCE): harmonizing water treatment systems with implementers' needs.

    Science.gov (United States)

    Goodman, Joseph; Caravati, Kevin; Foote, Andrew; Nelson, Molly; Woods, Emily

    2013-06-01

    One of the methods proposed to improve access to clean drinking water is the mobile packaged water treatment system (MPWTS). The lack of published system performance comparisons combined with the diversity of technology available and intended operating conditions make it difficult for stakeholders to choose the system best suited for their application. MPWTS are often deployed in emergency situations, making selection of the appropriate system crucial to avoiding wasted resources and loss of life. Measurable critical-to-quality characteristics (CTQs) and a system selection tool for MPWTS were developed by utilizing relevant literature, including field studies, and implementing and comparing seven different MPWTS. The proposed System Life Cycle Evaluation (SLiCE) method uses these CTQs to evaluate the diversity in system performance and harmonize relevant performance with stakeholder preference via a selection tool. Agencies and field workers can use SLiCE results to inform and drive decision-making. The evaluation and selection tool also serves as a catalyst for communicating system performance, common design flaws, and stakeholder needs to system manufacturers. The SLiCE framework can be adopted into other emerging system technologies to communicate system performance over the life cycle of use.

  12. EVALUATION OF VALUE STREAM MAPPING IN MANUFACTURING SYSTEMS REDESIGNING

    OpenAIRE

    Serrano , Ibon; Ochoa Laburu , Carlos; De Castro , Rodolfo

    2008-01-01

    Abstract The Value Stream Mapping (VSM) technique, developed within the lean production paradigm, was presented as an innovative graphic technique to help practitioners redesign production systems. This paper presents the results of a project whose main purpose is to evaluate the real applicability of VSM to redesign disconnected flow lines based on manufacturing environments with a diversity of logistical problems. The research was developed using multiple case study methodology i...

  13. Benchtop evaluation of pressure barrier insufflator and standard insufflator systems.

    Science.gov (United States)

    Nepple, Kenneth G; Kallogjeri, Dorina; Bhayani, Sam B

    2013-01-01

    Previous experimental research has reported minimal differences in pressure maintenance between different versions of standard insufflators (SI). However, a recent report identified potential clinical benefits with a valveless pressure barrier insufflator (PBI). We sought to perform a benchtop objective evaluation of SI and PBI systems. A rigid box system with continuous pressure manometry was used to evaluate a PBI (Surgiquest Airseal) and two SIs (SI1 = Stryker PneumoSure High Flow Insufflator and SI2 = Storz SCB Thermoflator). Pressure maintenance of 15 mmHg was evaluated during experimental conditions of leakage from a 5 mm port site, leakage from a 12 mm port site, and continuous suction. With leakage from the 5 mm port site, the PBI maintained pressure of >13 mmHg whereas the pressures dropped moderately with the SI1 (7-13 mmHg) and SI2 insufflators (3-7 mmHg) and did not regain goal pressure until leakage was stopped. With leakage from 12 mm port site, the PBI pressure decreased to 9-11 mmHg, whereas the SI1 and SI2 lost insufflation pressures completely. The PBI maintained pressure of >11 mmHg during continuous suction while the SI1 and SI2 lost pressure entirely, and actually showed negative pressure from air suction into the rigid box system. When evaluated statistically with the mixed model repeated measures ANOVA, the SI1 and SI2 performed similarly while the PBI maintained increased pressure. In the experimental rigid box system, the PBI more successfully maintained pressure in response to leakage and suction than SIs.

  14. Evaluating the success of the company designing the TQM System

    OpenAIRE

    Mitreva, Elizabeta; Taskov, Nako

    2014-01-01

    This paper proposes a methodology for evaluating the success of the designed and implemented system for TQM (audit) and its application in some Macedonian companies. Successful application of this methodology can only be achieved if business processes are designed and implemented with optimal utilization of resources, in order to work out the best from the first time, no defects, no loss of time and to the satisfaction of all users. This methodology has found a p...

  15. Teacher evaluation system, institutions of technology higher education: quality guidelines

    Directory of Open Access Journals (Sweden)

    Laura Belkis Parada Romero

    2016-01-01

    Full Text Available Due to the globalization of education, it has become prevalent to strengthen the quality systems to ensure that educational actors in higher education institutions are the best. In this context teachers are given a main role since they are cornerstones in educational processes. Currently, teacher quality is assessed through an assessment or evaluation system. Almost every university evaluates its teachers, but there is no legal regulation on how to do it, in most institutions there is a professional in charge of designing and applying assessment instruments according to the authors he/she prefers. In most universities, on the one hand, it is used a traditional questionnaire aiming to collect data about dimensions associated with teaching, on the other hand, there is another option in which assessment models include self-evaluation, as in some cases in Chile. That’s why one of the concerns of this research is to propose guidelines for a more qualitative and formative assessment not exclusively following political parameters –based on administrative decisions–, but following emerging proposals with a deeper analysis. Nowadays the main actors in teacher evaluation are teachers, students and administrative staff, every six months these actors are evaluated by using an assessment tool that they usually do not know. The research investigates the perception actors in teacher evaluation have regarding its objectives, methods and stages, so they put forward ideas on how to restructure the current institutional assessment and propose improvements aiming at both the quantitative aspect and the qualitative analysis of performances and skills.

  16. Evaluation of KFB-funded research on transport systems

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, D.; Knudsen, T.; Wegener, M.

    1999-09-01

    This report presents an evaluation of two research projects on transport systems, which have been financed fully or partially by KFB. The projects are: l. Systems analysis of transport markets at the Division of Transport and Location Analysis in the Department of Infrastructure and Planning of the Royal Institute of Technology, Stockholm; and 2. Planning, analysis and management in traffic networks - optimization models and methods at the Division of Optimization in the Department of Mathematics at Linkoeping University. The evaluation seeks to examine the scientific quality of the research and its relevance to the academic world and society. The two project teams prepared a self-assessment of their research activities and submitted copies of relevant publications. The evaluation committee visited both institutions and engaged the teams in discussions of their results and methodology. These visits occurred on June 1 and 2, 1999. This report is based on the self-assessments of the teams, the materials submitted and the meetings with the project teams. The evaluation and recommendations presented in the report are those of the reviewers and do not necessarily represent the views of KFB

  17. Evaluating Emulation-based Models of Distributed Computing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Stephen T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cyber Initiatives; Gabert, Kasimir G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Cyber Initiatives; Tarman, Thomas D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Emulytics Initiatives

    2017-08-01

    Emulation-based models of distributed computing systems are collections of virtual ma- chines, virtual networks, and other emulation components configured to stand in for oper- ational systems when performing experimental science, training, analysis of design alterna- tives, test and evaluation, or idea generation. As with any tool, we should carefully evaluate whether our uses of emulation-based models are appropriate and justified. Otherwise, we run the risk of using a model incorrectly and creating meaningless results. The variety of uses of emulation-based models each have their own goals and deserve thoughtful evaluation. In this paper, we enumerate some of these uses and describe approaches that one can take to build an evidence-based case that a use of an emulation-based model is credible. Predictive uses of emulation-based models, where we expect a model to tell us something true about the real world, set the bar especially high and the principal evaluation method, called validation , is comensurately rigorous. We spend the majority of our time describing and demonstrating the validation of a simple predictive model using a well-established methodology inherited from decades of development in the compuational science and engineering community.

  18. The human performance evaluation system at Virginia Power

    International Nuclear Information System (INIS)

    Smith, R.G. III.

    1989-01-01

    The safe operation of nuclear power plants requires high standards of performance, extensive training, and responsive management. Despite a utility's best efforts, inappropriate human actions do occur. Although such inappropriate actions will occur, it is believed that such actions can be minimized and managed. The Federal Aviation Administration has a successful program administered by the National Aeronautics and Space Administration. This program is called the Aviation Safety Reporting System (ASRS). Established in 1975, it is anonymous and nonpunitive. A trial program for several utilities was developed by the Institute of Nuclear Power Operations which used a concept similar to the ASRS reporting process. Based on valuable lessons learned by Virginia Power during the pilot program, an effort was made in 1986 to formalize the Human Performance Evaluation System (HPES) to establish an ongoing problem-solving system for evaluating human performance. Currently, 34 domestic utilities and 3 international utilities voluntarily participate in the implementation of the HPES. Each participating utility has selected and trained personnel to evaluate events involving human error and provide corrective action recommendations to prevent recurrence. It is believed that the use of the HPES can lead to improved safety and operation availability

  19. Deep Charging Evaluation of Satellite Power and Communication System Components

    Science.gov (United States)

    Schneider, T. A.; Vaughn, J. A.; Chu, B.; Wong, F.; Gardiner, G.; Wright, K. H.; Phillips, B.

    2016-01-01

    Deep charging, in contrast to surface charging, focuses on electron penetration deep into insulating materials applied over conductors. A classic example of this scenario is an insulated wire. Deep charging can pose a threat to material integrity, and to sensitive electronics, when it gives rise to an electrostatic discharge or arc. With the advent of Electric Orbit Raising, which requires spiraling through Earth's radiation belts, satellites are subjected to high energy electron environments which they normally would not encounter. Beyond Earth orbit, missions to Jupiter and Saturn face deep charging concerns due to the high energy radiation environments. While predictions can be made about charging in insulating materials, it is difficult to extend those predictions to complicated geometries, such as the case of an insulating coating around a small wire, or a non-uniform silicone grouting on a bus bar. Therefore, to conclusively determine the susceptibility of a system to arcs from deep charging, experimental investigations must be carried out. This paper will describe the evaluation carried out by NASA's Marshall Space Flight Center on subscale flight-like samples developed by Space Systems/Loral, LLC. Specifically, deep charging evaluations of solar array wire coupons, a photovoltaic cell coupon, and a coaxial microwave transmission cable, will be discussed. The results of each evaluation will be benchmarked against control sample tests, as well as typical power system levels, to show no significant deep charging threat existed for this set of samples under the conditions tested.

  20. Comparison of economic evaluation methodology between levelized method and the evaluation system in China

    International Nuclear Information System (INIS)

    Zhang Shengli

    2005-01-01

    Different methodology would bring different results. This paper includes an introduction of levelized discounted generation cost methodology as well as that of Chinese system, respectively. In general, there have two key indices in Chinese evaluation system, they are generation cost and electricity sales price to the grid. This paper contains a description of cost breakdown and calculation procedure for each index. Comparison between these two methods and the primary differences are also included. For the first time, equations for calculating generation cost and selling price to the grid based on Chinese system have been derived, and its accuracy has been shown through running the special computer program. The two systems are quite different in many aspects. Firstly, levelized generation cost is always calculated with discounted method that excluded in Chinese system. Secondly, levelized generation cost is a single and constant value that would not change over the economic life while generation cost in Chinese system is estimated on a year by year base. Thirdly, the makeup of generation cost in Chinese system is different from that of levelized system since taxes and dividend share removed. Finally, the electricity sales price in Chinese system is more similar to levelized generation cost. (authors)

  1. Wireless and wearable EEG system for evaluating driver vigilance.

    Science.gov (United States)

    Lin, Chin-Teng; Chuang, Chun-Hsiang; Huang, Chih-Sheng; Tsai, Shu-Fang; Lu, Shao-Wei; Chen, Yen-Hsuan; Ko, Li-Wei

    2014-04-01

    Brain activity associated with attention sustained on the task of safe driving has received considerable attention recently in many neurophysiological studies. Those investigations have also accurately estimated shifts in drivers' levels of arousal, fatigue, and vigilance, as evidenced by variations in their task performance, by evaluating electroencephalographic (EEG) changes. However, monitoring the neurophysiological activities of automobile drivers poses a major measurement challenge when using a laboratory-oriented biosensor technology. This work presents a novel dry EEG sensor based mobile wireless EEG system (referred to herein as Mindo) to monitor in real time a driver's vigilance status in order to link the fluctuation of driving performance with changes in brain activities. The proposed Mindo system incorporates the use of a wireless and wearable EEG device to record EEG signals from hairy regions of the driver conveniently. Additionally, the proposed system can process EEG recordings and translate them into the vigilance level. The study compares the system performance between different regression models. Moreover, the proposed system is implemented using JAVA programming language as a mobile application for online analysis. A case study involving 15 study participants assigned a 90 min sustained-attention driving task in an immersive virtual driving environment demonstrates the reliability of the proposed system. Consistent with previous studies, power spectral analysis results confirm that the EEG activities correlate well with the variations in vigilance. Furthermore, the proposed system demonstrated the feasibility of predicting the driver's vigilance in real time.

  2. Evaluation of a novel compact shearography system with DOE configuration

    Science.gov (United States)

    da Silva, Fabio Aparecido Alves; Willemann, Daniel Pedro; Fantin, Analucia Vieira; Benedet, Mauro Eduardo; Gonçalves, Armando Albertazzi

    2018-05-01

    The most common optical configuration used to produce the lateral shifted images, in a Shearography system, is the Modified Michelson interferometer, because of its simple configuration. Tests carried out in recent years have shown that the modified interferometer of Michelson is a device that presents good results in a laboratory environment, but still presents difficulties in the field. These difficulties were the main motivation for the development of a more robust system, able to operate in unstable environments. This paper presents a new shearography configuration based on Diffractive Optical Element (DOE). Different from the diffractive common-path setups found in literature, in the proposed configuration, the DOE is positioned between the image sensor and the objective lens and mounted on a flexible holder, which has an important function to promote the system's robustness. Another advantage of the proposed system is in respect to phase shifting, since it is insensitive to wavelength variations. The lateral movement of the DOE produces a phase shifting in the shearography system. Since the pitch of the diffractive grating used is about 60 times greater than the wavelength of a green laser, the DOE configuration becomes much more robust to external influences compared to the Michelson Interferometer configuration. This work also presents an evaluation of the proposed shearography system designed, and some comparative results regarding a classical shearography system.

  3. Safety analysis and evaluation methodology for fusion systems

    International Nuclear Information System (INIS)

    Fujii-e, Y.; Kozawa, Y.; Namba, C.

    1987-03-01

    Fusion systems which are under development as future energy systems have reached a stage that the break even is expected to be realized in the near future. It is desirable to demonstrate that fusion systems are well acceptable to the societal environment. There are three crucial viewpoints to measure the acceptability, that is, technological feasibility, economy and safety. These three points have close interrelation. The safety problem is more important since three large scale tokamaks, JET, TFTR and JT-60, start experiment, and tritium will be introduced into some of them as the fusion fuel. It is desirable to establish a methodology to resolve the safety-related issues in harmony with the technological evolution. The promising fusion system toward reactors is not yet settled. This study has the objective to develop and adequate methodology which promotes the safety design of general fusion systems and to present a basis for proposing the R and D themes and establishing the data base. A framework of the methodology, the understanding and modeling of fusion systems, the principle of ensuring safety, the safety analysis based on the function and the application of the methodology are discussed. As the result of this study, the methodology for the safety analysis and evaluation of fusion systems was developed. New idea and approach were presented in the course of the methodology development. (Kako, I.)

  4. Performance Evaluation of a Small Scale Modular Solar Trigeneration System

    Directory of Open Access Journals (Sweden)

    Handong Wang

    2014-01-01

    Full Text Available In order to improve the efficiency of solar thermal power (STP system, a novel modular system combining cooling, heating, and power generation (CCHP is proposed and introduced in this work. This modular CCHP system can simultaneously provide 10 kW electricity, −15~5°C coolant, and 60°C hot water to meet the requirements of cooling, heating, and electricity in a general family or other fields. The flow chart and working process of the modular system are introduced, based on which the energy and exergy efficiencies at the CCHP and STP operation modes are primarily evaluated and discussed. The results show that when the output electricity is constant, the overall efficiencies of energy and exergy of the system operating at the CCHP mode are 9.37 times and 2.62 times as big as those of the system operating at the STP mode, respectively. Thus, the modular solar thermal CCHP system can improve the energy and exergy efficiencies. Furthermore, calculation shows that both the overall energy and exergy efficiencies decrease with increase of inlet vapor temperature at given inlet vapor pressure, but both the efficiencies increase with increase of inlet vapor pressure at given inlet temperature.

  5. Towards an evaluation framework for complex social systems

    Science.gov (United States)

    McDonald, Diane M.; Kay, Nigel

    While there is growing realisation that the world in which we live in is highly complex with multiple interdependencies and irreducibly open to outside influence, how to make these 'systems' more manageable is still a significant outstanding issue. As (2004) suggests, applying the theoretical principles of Complex Systems may help solve complex problems in this complex world. While Bar-Yam provides examples of forward-thinking organisations which have begun to see the relevance of complex systems principles, for many organisations the language and concepts of complexity science such as self-organisation and unpredictability while they make theoretical sense offer no practical or acceptable method of implementation to those more familiar with definitive facts and classical hierarchical, deterministic approaches to control. Complexity Science explains why designed systems or interventions may not function as anticipated in differing environments, without providing a silver bullet which enables control or engineering of the system to ensure the desired results. One familiar process which might, if implemented with complex systems in mind, provide the basis of an accessible and understandable framework that enables policy makers and practitioners to better design and manage complex socio-technical systems is that of evaluation.

  6. Evaluation of digital detector arrays systems for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Aline S.S.; Oliveira, Davi F.; Gomes, Célio S.; Azeredo, Soraia R.; Lopes, Ricardo T., E-mail: aline@lin.ufrj.br, E-mail: davi@lin.ufrj.br.br, E-mail: celio@lin.ufrj.br, E-mail: soraia@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br, E-mail: davi.oliveira@uerj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear

    2017-07-01

    Digital Detector Arrays (DDA) or Flat Panel Detector (FPD) is a highly efficient technique that is used in nondestructive testing of internal features of an object. The evaluation of DDA systems for industrial radiography is important to ensure the image quality and to enables long-term stability of this system. This evaluation is specified by ASTM E2737 - 10, which describes the fundamental parameters of DDA systems to be measured. The tests require the usage of either the five-groove wedge or the duplex plate phantom with separate Image Quality Indicators (IQIs). The purpose of this work was evaluate the radiographic performance achieved using both techniques in two DDA systems manufactured by GEIT: DXR250P and DXR250V, which have thallium-doped cesium iodide (CsI:Tl) and terbium-doped gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb - GOS) scintillators, respectively. For this purpose, it was used an X-ray equipment as radiation source. The image quality parameters analyzed were Image Lag (IL), Offset Level (OL), Bad Pixel distribution, Burn In (BI), Spatial Resolution (SR), Material Thickness Range (MTR), Contrast Sensitivity (CS), Signal Level (SL) and Signal-to-Noise Ratio (SNR). As result of this study, has been observed that the use of the five-groove wedge phantom made the measurements to become easier to execute. Regarding the DDA system, the DXR250P presented more IL and BI, but produced images with better CS and SNR and needed a dose almost twice smaller than the DXR250V to achieve a similar SL. (author)

  7. Evaluation of digital detector arrays systems for industrial radiography

    International Nuclear Information System (INIS)

    Silva, Aline S.S.; Oliveira, Davi F.; Gomes, Célio S.; Azeredo, Soraia R.; Lopes, Ricardo T.

    2017-01-01

    Digital Detector Arrays (DDA) or Flat Panel Detector (FPD) is a highly efficient technique that is used in nondestructive testing of internal features of an object. The evaluation of DDA systems for industrial radiography is important to ensure the image quality and to enables long-term stability of this system. This evaluation is specified by ASTM E2737 - 10, which describes the fundamental parameters of DDA systems to be measured. The tests require the usage of either the five-groove wedge or the duplex plate phantom with separate Image Quality Indicators (IQIs). The purpose of this work was evaluate the radiographic performance achieved using both techniques in two DDA systems manufactured by GEIT: DXR250P and DXR250V, which have thallium-doped cesium iodide (CsI:Tl) and terbium-doped gadolinium oxysulfide (Gd 2 O 2 S:Tb - GOS) scintillators, respectively. For this purpose, it was used an X-ray equipment as radiation source. The image quality parameters analyzed were Image Lag (IL), Offset Level (OL), Bad Pixel distribution, Burn In (BI), Spatial Resolution (SR), Material Thickness Range (MTR), Contrast Sensitivity (CS), Signal Level (SL) and Signal-to-Noise Ratio (SNR). As result of this study, has been observed that the use of the five-groove wedge phantom made the measurements to become easier to execute. Regarding the DDA system, the DXR250P presented more IL and BI, but produced images with better CS and SNR and needed a dose almost twice smaller than the DXR250V to achieve a similar SL. (author)

  8. Evaluation of a low-dose neonatal chest radiographic system

    International Nuclear Information System (INIS)

    Burton, E.M.; Kirks, D.R.; Strife, J.L.; Henry, G.C.; Kereiakes, J.G.

    1988-01-01

    A new low-dose chest radiographic system for use in the neonatal nursery was evaluated. This test system, composed of a Du Pont Kevlar fiber-front cassette, Quanta fast-detail screen, Cronex 4L film (wide latitude), and additional yttrium filtration (0.1 mm), reduced the radiation dose in neonatal chest radiography by 69% (0.9 vs 2.9 mrad [0.009 vs 0.029 mGy]) as compared with a conventional system without added yttrium filtration; the thyroid dose was reduced by 76% (0.9 vs 3.7 mrad [0.009 vs 0.037 mGy]). The cumulative dose reduction was achieved through a combination of factors, including (1) beam hardening by the added yttrium filter, (2) increased X-ray transmission through the Kevlar cassette, and (3) a fast film-screen combination. Scatter radiation at distances of 1 and 6 ft. (0.3 and 1.8 m) was negligible for both systems. Image sharpness was compared for the conventional system with and without added yttrium filtration and for the Kevlar system with yttrium. Although sharpness of bony detail was unchanged by adding yttrium filtration to the conventional system, a decrease in sharpness was noted with the Kevlar system. Because image sharpness was affected in the test system, we are not using the Kevlar-Cronex 4L system for mobile chest radiography in the neonatal intensive care unit, despite dose reductions. However, further study is recommended to determine if there is a slower film-screen combination with yttrium filtration that will not degrade image sharpness

  9. Evaluating physical protection systems of licensed nuclear facilities using systems engineered inspection guidance

    International Nuclear Information System (INIS)

    Bradley, R.T.; Olson, A.W.; Rogue, F.; Scala, S.; Richard, E.W.

    1980-01-01

    The Lawrence Livermore National Laboratory (LLNL) and the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) have applied a systems engineering approach to provide the NRC Office of Inspection and Enforcement (IE) with improved methods and guidance for evaluating the physical protection systems of licensed nuclear facilities

  10. The Artemis workbench for system-level performance evaluation of embedded systems

    NARCIS (Netherlands)

    Pimentel, A.D.

    2008-01-01

    In this paper, we present an overview of the Artemis workbench, which provides modelling and simulation methods and tools for efficient performance evaluation and exploration of heterogeneous embedded multimedia systems. More specifically, we describe the Artemis system-level modelling methodology,

  11. Evaluating accounting information systems that support multiple GAAP reporting using Normalized Systems Theory

    NARCIS (Netherlands)

    Vanhoof, E.; Huysmans, P.; Aerts, Walter; Verelst, J.; Aveiro, D.; Tribolet, J.; Gouveia, D.

    2014-01-01

    This paper uses a mixed methods approach of design science and case study research to evaluate structures of Accounting Information Systems (AIS) that report in multiple Generally Accepted Accounting Principles (GAAP), using Normalized Systems Theory (NST). To comply with regulation, many companies

  12. Objective Evaluation in an Online Geographic Information System Certificate Program

    Directory of Open Access Journals (Sweden)

    Scott L. WALKER

    2005-01-01

    Full Text Available Objective Evaluation in an Online Geographic Information System Certificate Program Asst. Professor. Dr. Scott L. WALKER Texas State University-San Marcos San Marcos, Texas, USA ABSTRACT Departmental decisions regarding distance education programs can be subject to subjective decision-making processes influenced by external factors such as strong faculty opinions or pressure to increase student enrolment. This paper outlines an evaluation of a departmental distance-education program. The evaluation utilized several methods that strived to inject objectivity in evaluation and subsequent decision-making. A rapid multi-modal approach included evaluation methods of (1 considering the online psychosocial learning environment, (2 content analyses comparing the online version of classes to face-to-face versions, (3 cost comparisons in online vs. face-to-face classes, (4 student outcomes, (5 student retention, and (6 benchmarking. These approaches offer opportunities for departmental administrators and decision-making committees to make judgments informed by facts rather than being influenced by the emotions, beliefs, or opinions of organizational dynamics.

  13. Research and development for evaluation system of solar cell

    Energy Technology Data Exchange (ETDEWEB)

    1986-08-01

    In order to evaluate the performance and capability of solar cell properly and impartially, the evaluation systems for the performance and reliability have been assured. The results are as follows. 1. Development for performance evaluation method; (1) The international comparisons of standard solar cell calibration methods and our method has been assured to be mostly near to the average value. (2) Experimental solar cell has been made and the indoors and outdoors evaluation of solar cell module have become to be possible with same accuracy. (3) As the spectro-radiometer of high performance have been developed, the measurements of the output of the solar cell module have become possible, monitering spectrum of wide range of natural solar beam. (4) With use of several kinds of standard solar cell, measurement errors have been assured. (5) As for nominal operating cell temperature of module, experimental researches have been done indoors and outdoors and the diffeneces have been assured. 2. Development of reliability evaluation method; (1) In outdoor exposure test, the basic data of the accelerating degradation test have been accumulated and it has been assured that the degradation of crystal type is few. (2) By the acceleration degradation test with use of weathermeter, and temperature and humidity cycling test device, the proceses of degradation have been assured. (3) In the processes of enviromental tests and mechanical strength tests, remarkable degradation has not been recognized.(1 tab)

  14. Development of design window evaluation and display system. 1. System development and performance confirmation

    International Nuclear Information System (INIS)

    Muramatsu, Toshiharu; Yamaguchi, Akira

    2003-07-01

    Purpose: The work was performed to develop a design window evaluation and display system for the purpose of obtaining the effects of various design parameters on the typical thermal hydraulic issues resulting from a use of various kind of working fluid etc. easily. Method: The function of the system were 'confirmation of design margin' of the present design, 'confirmation of the affected design zone' when a designer changed some design parameter, and search for an design improvement' for design optimization. The system was developed using existing soft wares on PC and the database relating analytical results of typical thermal hydraulic issues provided by separate work. Results: (1) System design: In order to develop a design window evaluation and display system, 'numerical analysis unit', 'statistical analysis unit', 'MMI unit', 'optimization unit' were designed based on the result of selected optimization procedure and display visualization. Further, total system design was performed combining these units. Typical thermal hydraulic issues to be considered are upper plenum thermal hydraulics, thermal stratification, free surface sloshing, flow-induced vibration of a heat exchanger and thermal striping in the T-junction piping systems. (2) Development of prototype system and a functional check: A prototype system of a design window evaluation and display system was developed and the functions were confirmed as was planned. (author)

  15. Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions

    Science.gov (United States)

    Sawin, C. F.; Nicogossian, A. E.; Rummel, J. A.; Michel, E. L.

    1976-01-01

    Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.

  16. Evaluation of on-site wastewater treatment systems

    International Nuclear Information System (INIS)

    Dunn, J.

    2002-01-01

    'Full text:' This presentation will describe the nature, scope, and findings of a program designed to conduct a third-party group evaluation of wastewater denitrification technologies appropriate for low-flow systems, partially funded by a grant from the Pennsylvania Department of Environmental Protection (PADEP). The objective of this program is to verify the performance of products that provide nutrient reduction in wastewater from a variety of sources, including domestic wastewater, agricultural runoff, or other waste streams. The evaluation process will be overseen and coordinated by the Environmental Technology Evaluation Center (EvTEC), a program of the Civil Engineering Research Foundation (CERF), the research and technology transfer arm of the American Society of Civil Engineers (ASCE). EvTEC is a pilot program evaluating innovative environmental technologies under the US Environmental Protection Agency's (USEPA) Environmental Technology Verification (ETV) Program. Among other performance issues, the potential energy savings of using nutrient reducing technologies scaled to treat low flows - larger than an individual septic tank but smaller than that of a conventional wastewater treatment plant - will be assessed. The energy savings realized by reduced construction and equipment transport costs alone could make low-flow nutrient reduction technologies viable options for rural communities, small farms, and other low-flow settings. The evaluation is being funded in part by PADEP, which is sponsoring this evaluation due to its interest in developing low-cost wastewater treatment technologies for Pennsylvania's rural communities. However, the evaluation is national in scope, and participants will come from all areas of the country. The presentation will include a description of the process for establishing the testing protocol, testing results from various nutrient reducing technologies, and obstacles encountered and lessons learned during the process. (author)

  17. Initial evaluation of a full breast digital system

    International Nuclear Information System (INIS)

    Vano, E.; Fernandez, J.M.; Chevalier, M.; Moran, P.; Cepeda, T.; Fabra, A.; Alvarez Pedrosa, C.S.

    2001-01-01

    Full-field digital mammography systems have been developed for overcoming the limitations of the screen-film mammography. This work is focused on the system from GE Medical Systems (Senographe 2000) which has been recently installed in our institution. The imager consists of a thin Ics:Tl scintillator which is in narrow contact with an array of amorphous silicon detectors mounted in a single panel. The flat-panel detector is integrated in a x-ray system with a high-frequency generator Senographe DM and dual track anode of Mo and Rh with Mo and Rh filtration. The aim of this work is to analyse the defaults exposure factors set at the installation of the x-ray unit. The image quality has been evaluated by using one of the two phantoms recommended in the ACR Accreditation Program. Phantom images were obtained at each of the three available imaging modes: contrast (CNT), standard (STD) and DOSE. While maintaining the defaults of kilovoltage and anode/filter combination, phantom images were obtained at lower dose vales. The contrast noise ratio (CNR) was calculated for each of the low contrast objects (masses) of the phantom images and the detail visibility was also evaluated. The results obtained for both parameters reveal that similar image quality can be obtained with significant reductions of the average glandular dose. (author)

  18. Evaluation of two ozone air quality modelling systems

    Directory of Open Access Journals (Sweden)

    S. Ortega

    2004-01-01

    Full Text Available The aim of this paper is to compare two different modelling systems and to evaluate their ability to simulate high values of ozone concentration in typical summer episodes which take place in the north of Spain near the metropolitan area of Barcelona. As the focus of the paper is the comparison of the two systems, we do not attempt to improve the agreement by adjusting the emission inventory or model parameters. The first model, or forecasting system, is made up of three modules. The first module is a mesoscale model (MASS. This provides the initial condition for the second module, which is a nonlocal boundary layer model based on the transilient turbulence scheme. The third module is a photochemical box model (OZIPR, which is applied in Eulerian and Lagrangian modes and receives suitable information from the two previous modules. The model forecast is evaluated against ground base stations during summer 2001. The second model is the MM5/UAM-V. This is a grid model designed to predict the hourly three-dimensional ozone concentration fields. The model is applied during an ozone episode that occurred between 21 and 23 June 2001. Our results reflect the good performance of the two modelling systems when they are used in a specific episode.

  19. A multicriteria approach to evaluate district heating system options

    Energy Technology Data Exchange (ETDEWEB)

    Ghafghazi, S.; Sowlati, T. [Department of Wood Science, University of British Columbia, 2931-2424 Main Mall, Vancouver, BC (Canada); Sokhansanj, S. [Department of Chemical and Biological Engineering, University of British Columbia, 2360 East Mall, Vancouver, BC (Canada); Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Melin, S. [Department of Chemical and Biological Engineering, University of British Columbia, 2360 East Mall, Vancouver, BC (Canada); Delta Research Corporation, Delta, BC (Canada)

    2010-04-15

    District energy systems, in which renewable energy sources may be utilized, are centralized systems to provide energy to residential and commercial buildings. The aim of this paper is to evaluate and rank energy sources available for a case of district heating system in Vancouver, Canada, based on multiple criteria and the view points of different stakeholders, and to show how communication would affect the ranking of alternatives. The available energy sources are natural gas, biomass (wood pellets), sewer heat, and geothermal heat. The evaluation criteria include GHG emissions, particulate matter emissions, maturity of technology, traffic load, and local source. In order to rank the energy options the PROMETHEE method is used. In this paper, two different scenarios were developed to indicate how the communication between the stakeholders would affect their preferences about criteria weights and would change the ranking of alternatives. The result of this study shows that without communication the best energy source for the considered district energy system is different for different stakeholders. While, addressing concerns through efficient communication would result in a general consensus. In this case, wood pellet is the best energy alternative for all the stakeholders. (author)

  20. Module-based quality system functionality evaluation in production logistics

    Energy Technology Data Exchange (ETDEWEB)

    Khabbazi, M.R.; Wikander, J.; Onori, M.; Maffei, A.; Chen, D.

    2016-07-01

    This paper addresses a comprehensive modeling and functionality evaluation of a module-based quality system in production logistics at the highest domain abstract level of business processes. All domain quality business processes and quality data transactions are modeled using BPMN and UML tools and standards at the business process and data modeling. A modular web-based prototype is developed to evaluate the models addressing the quality information system functionality requirements and modularity in production logistics through data scenarios and data queries. Using the object-oriented technique in design at the highest domain level, the proposed models are subject further development in the lower levels for the implementing case. The models are specifically able to manipulate all quality operations including remedy and control in a lot-based make-to-order production logistics system as an individual module. Due to the specification of system as domain design structure, all proposed BPMs, data models, and the actual database prototype are seen referential if not a solution as a practical “to-be” quality business process re-engineering template. This paper sets out to provide an explanatory approach using different practical technique at modeling steps as well as the prototype implementation. (Author)