WorldWideScience

Sample records for system performance evaluation

  1. Human Performance Evaluation System

    International Nuclear Information System (INIS)

    Hardwick, R.J. Jr.

    1985-01-01

    Operating nuclear power plants requires high standards of performance, extensive training and responsive management. Despite our best efforts inappropriate human actions do occur, but they can be managed. An extensive review of License Event Reports (LERs) was conducted which indicated continual inadequacy in human performance and in evaluation of root causes. Of some 31,000 LERs, about 5,000 or 16% were directly attributable to inappropriate actions. A recent analysis of 87 Significant Event Reports (issued by INPO in 1983) identified inappropriate actions as being the most frequent root cause (44% of the total). A more recent analysis of SERs issued in 1983 and 1984 indicate that 52% of the root causes were attributed to human performance. The Human Performance Evaluation System (HPES) is a comprehensive, coordinated utility/industry system for evaluating and reporting human performance situtations. HPES is a result of the realization that current reporting system provide limited treatment of human performance and rarely provide adequate information about root causes of inappropriate actions by individuals. The HPES was implemented to identify and eliminate root causes of inappropriate actions

  2. Evaluation of EIT system performance.

    Science.gov (United States)

    Yasin, Mamatjan; Böhm, Stephan; Gaggero, Pascal O; Adler, Andy

    2011-07-01

    An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach to evaluate the performance of the EIT systems. The system to be tested is connected to a saline phantom in which calibrated contrasting test objects are systematically positioned using a position controller. A set of evaluation parameters are proposed which characterize (i) data and image noise, (ii) data accuracy, (iii) detectability of single contrasts and distinguishability of multiple contrasts, and (iv) accuracy of reconstructed image (amplitude, resolution, position and ringing). Using this approach, we evaluate three different EIT systems and illustrate the use of these tools to evaluate and compare performance. In order to facilitate the use of this approach, all details of the phantom, test objects and position controller design are made publicly available including the source code of the evaluation and reporting software.

  3. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  4. Performance Evaluation Of Behavioral Biometric Systems

    OpenAIRE

    Cherifi , Fouad; Hemery , Baptiste; Giot , Romain; Pasquet , Marc; Rosenberger , Christophe

    2009-01-01

    We present in this chapter an overview of techniques for the performance evaluation of behavioral biometric systems. The BioAPI standard that defines the architecture of a biometric system is presented in the first part of the chapter... The general methodology for the evaluation of biometric systems is given including statistical metrics, definition of benchmark databases and subjective evaluation. These considerations rely with the ISO/IEC19795-1 standard describing the biometric performanc...

  5. An hierarchical approach to performance evaluation of expert systems

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Kavi, Srinu

    1985-01-01

    The number and size of expert systems is growing rapidly. Formal evaluation of these systems - which is not performed for many systems - increases the acceptability by the user community and hence their success. Hierarchical evaluation that had been conducted for computer systems is applied for expert system performance evaluation. Expert systems are also evaluated by treating them as software systems (or programs). This paper reports many of the basic concepts and ideas in the Performance Evaluation of Expert Systems Study being conducted at the University of Southwestern Louisiana.

  6. Plant operator performance evaluation system

    International Nuclear Information System (INIS)

    Ujita, Hiroshi; Fukuda, Mitsuko; Kubota, Ryuji.

    1989-01-01

    A plant operator performance evaluation system to analyze plant operation records during accident training and to identify and classify operator errors has been developed for the purpose of supporting realization of a training and education system for plant operators. A knowledge engineering technique was applied to evaluation of operator behavior by both even-based and symptom-based procedures, in various situations including event transition due to multiple failures or operational errors. The system classifies the identified errors as to their single and double types based on Swain's error classification and the error levels reflecting Rasmussen's cognitive level, and it also evaluates the effect of errors on plant state and then classifies error influence, using 'knowledge for phenomena and operations', as represented by frames. It has additional functions for analysis of error statistics and knowledge acquisition support of 'knowledge for operations'. The system was applied to a training analysis for a scram event in a BWR plant, and its error analysis function was confirmed to be effective by operational experts. (author)

  7. Performance evaluation of communication systems via importance sampling

    NARCIS (Netherlands)

    Remondo Bueno, D.

    2000-01-01

    In the design and development of telecommunication systems, the preparation of experiments can be made more effective by predicting the system performance and its dependence on the different system parameters. This can be done by modeling the system and using performance evaluation methods. This

  8. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A Process For Performance Evaluation Of Real-Time Systems

    Directory of Open Access Journals (Sweden)

    Andrew J. Kornecki

    2003-12-01

    Full Text Available Real-time developers and engineers must not only meet the system functional requirements, but also the stringent timing requirements. One of the critical decisions leading to meeting these timing requirements is the selection of an operating system under which the software will be developed and run. Although there is ample documentation on real-time systems performance and evaluation, little can be found that combines such information into an efficient process for use by developers. As the software industry moves towards clearly defined processes, creation of appropriate guidelines describing a process for performance evaluation of real-time system would greatly benefit real-time developers. This technology transition research focuses on developing such a process. PROPERT (PROcess for Performance Evaluation of Real Time systems - the process described in this paper - is based upon established techniques for evaluating real-time systems. It organizes already existing real-time performance criteria and assessment techniques in a manner consistent with a well-formed process, based on the Personal Software Process concepts.

  10. Evaluating Models of Human Performance: Safety-Critical Systems Applications

    Science.gov (United States)

    Feary, Michael S.

    2012-01-01

    This presentation is part of panel discussion on Evaluating Models of Human Performance. The purpose of this panel is to discuss the increasing use of models in the world today and specifically focus on how to describe and evaluate models of human performance. My presentation will focus on discussions of generating distributions of performance, and the evaluation of different strategies for humans performing tasks with mixed initiative (Human-Automation) systems. I will also discuss issues with how to provide Human Performance modeling data to support decisions on acceptability and tradeoffs in the design of safety critical systems. I will conclude with challenges for the future.

  11. Virginia power's human performance evaluation system (HPES)

    International Nuclear Information System (INIS)

    Patterson, W.E.

    1991-01-01

    This paper reports on the Human Performance Evaluation System (HPES) which was initially developed by the Institute of Nuclear Power Operations (INPO) using the Aviation Safety Reporting System (ASRS) as a guide. After a pilot program involving three utilities ended in 1983, the present day program was instituted. A methodology was developed, for specific application to nuclear power plant employees, to aid trained coordinators/evaluators in determining those factors that exert a negative influence on human behavior in the nuclear power plant environment. HPES is for anyone and everyone on site, from contractors to plant staff to plant management. No one is excluded from participation. Virginia Power's HPES program goal is to identify and correct the root causes of human performance problems. Evaluations are performed on reported real or perceived conditions that may have an adverse influence on members of the nuclear team. A report is provided to management identifying root cause and contributing factors along with recommended corrective actions

  12. Formal Implementation of a Performance Evaluation Model for the Face Recognition System

    Directory of Open Access Journals (Sweden)

    Yong-Nyuo Shin

    2008-01-01

    Full Text Available Due to usability features, practical applications, and its lack of intrusiveness, face recognition technology, based on information, derived from individuals' facial features, has been attracting considerable attention recently. Reported recognition rates of commercialized face recognition systems cannot be admitted as official recognition rates, as they are based on assumptions that are beneficial to the specific system and face database. Therefore, performance evaluation methods and tools are necessary to objectively measure the accuracy and performance of any face recognition system. In this paper, we propose and formalize a performance evaluation model for the biometric recognition system, implementing an evaluation tool for face recognition systems based on the proposed model. Furthermore, we performed evaluations objectively by providing guidelines for the design and implementation of a performance evaluation system, formalizing the performance test process.

  13. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.; Gurbuz, E.

    1993-03-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSCsuperconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  14. Supplier Performance Evaluation and Rating System (SPEARS)

    International Nuclear Information System (INIS)

    Oged, M.; Warner, D.G.; Gurbuz, E.

    1994-01-01

    The SSCL Magnet Quality Assurance Department has implemented a Supplier Performance Evaluation and Rating System (SPEARS) to assess supplier performance throughout the development and production stages of the SSCL program. The main objectives of SPEARS are to promote teamwork and recognize performance. This paper examines the current implementation of SPEARS. MSD QA supports the development and production of SSC superconducting magnets while implementing the requirements of DOE Order 5700.6C. The MSD QA program is based on the concept of continuous improvement in quality and productivity. The QA program requires that procurement of items and services be controlled to assure conformance to specification. SPEARS has been implemented to meet DOE requirements and to enhance overall confidence in supplier performance. Key elements of SPEARS include supplier evaluation and selection as well as evaluation of furnished quality through source inspection, audit, and receipt inspection. These elements are described in this paper

  15. The human performance evaluation system at Virginia Power

    International Nuclear Information System (INIS)

    Smith, R.G. III.

    1989-01-01

    The safe operation of nuclear power plants requires high standards of performance, extensive training, and responsive management. Despite a utility's best efforts, inappropriate human actions do occur. Although such inappropriate actions will occur, it is believed that such actions can be minimized and managed. The Federal Aviation Administration has a successful program administered by the National Aeronautics and Space Administration. This program is called the Aviation Safety Reporting System (ASRS). Established in 1975, it is anonymous and nonpunitive. A trial program for several utilities was developed by the Institute of Nuclear Power Operations which used a concept similar to the ASRS reporting process. Based on valuable lessons learned by Virginia Power during the pilot program, an effort was made in 1986 to formalize the Human Performance Evaluation System (HPES) to establish an ongoing problem-solving system for evaluating human performance. Currently, 34 domestic utilities and 3 international utilities voluntarily participate in the implementation of the HPES. Each participating utility has selected and trained personnel to evaluate events involving human error and provide corrective action recommendations to prevent recurrence. It is believed that the use of the HPES can lead to improved safety and operation availability

  16. A new method to evaluate human-robot system performance

    Science.gov (United States)

    Rodriguez, G.; Weisbin, C. R.

    2003-01-01

    One of the key issues in space exploration is that of deciding what space tasks are best done with humans, with robots, or a suitable combination of each. In general, human and robot skills are complementary. Humans provide as yet unmatched capabilities to perceive, think, and act when faced with anomalies and unforeseen events, but there can be huge potential risks to human safety in getting these benefits. Robots provide complementary skills in being able to work in extremely risky environments, but their ability to perceive, think, and act by themselves is currently not error-free, although these capabilities are continually improving with the emergence of new technologies. Substantial past experience validates these generally qualitative notions. However, there is a need for more rigorously systematic evaluation of human and robot roles, in order to optimize the design and performance of human-robot system architectures using well-defined performance evaluation metrics. This article summarizes a new analytical method to conduct such quantitative evaluations. While the article focuses on evaluating human-robot systems, the method is generally applicable to a much broader class of systems whose performance needs to be evaluated.

  17. The JAERI code system for evaluation of BWR ECCS performance

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Akimoto, Masayuki; Asahi, Yoshiro; Abe, Kiyoharu; Muramatsu, Ken; Araya, Fumimasa; Sato, Kazuo

    1982-12-01

    Development of respective computer code system of BWR and PWR for evaluation of ECCS has been conducted since 1973 considering the differences of the reactor cooling system, core structure and ECCS. The first version of the BWR code system, of which developmental work started earlier than that of the PWR, has been completed. The BWR code system is designed to provide computational tools to analyze all phases of LOCAs and to evaluate the performance of the ECCS including an ''Evaluation Model (EM)'' feature in compliance with the requirements of the current Japanese Evaluation Guideline of ECCS. The BWR code system could be used for licensing purpose, i.e. for ECCS performance evaluation or audit calculations to cross-examine the methods and results of applicants or vendors. The BWR code system presented in this report comprises several computer codes, each of which analyzes a particular phase of a LOCA or a system blowdown depending on a range of LOCAs, i.e. large and small breaks in a variety of locations in the reactor system. The system includes ALARM-B1, HYDY-B1 and THYDE-B1 for analysis of the system blowdown for various break sizes, THYDE-B-REFLOOD for analysis of the reflood phase and SCORCH-B2 for the calculation of the fuel assembl hot plane temperature. When the multiple codes are used to analyze a broad range of LOCA as stated above, it is very important to evaluate the adequacy and consistency between the codes used to cover an entire break spectrum. The system consistency together with the system performance are discussed for a large commercial BWR. (author)

  18. Performance evaluation of photovoltaic systems on Kuwaiti schools’ rooftop

    International Nuclear Information System (INIS)

    Al-Otaibi, A.; Al-Qattan, A.; Fairouz, F.; Al-Mulla, A.

    2015-01-01

    Highlights: • Evaluation of rooftop PV installations at 2 Kuwaiti schools was carried out. • Lack of real plants data in the region and specifically Kuwait motivated the work. • Automated cleaning system allowed for minimization of soiling loss. • The average PV system performance was greater than 76%. • Schools show high potential for rooftop installations. - Abstract: Photovoltaic (PV) is a high-potential renewable energy technology for Kuwait to pursue due to high daily irradiation, and has garnered local attention in recent years due to the growing energy demand and concerns over climate change. As yet, no data are available regarding the actual performance of PV systems in Kuwait’s harsh environment. This paper presents a 12-month-long performance evaluation of the first 85.05 kW p and 21.6 kW p copper indium gallium selenide (CIGS) thin film, grid-connected PV systems on the rooftops of two schools. The schools’ monthly energy consumption and PV generation profiles, the actual performance of the PV plants, the effectiveness of automated cleaning systems on the power output, and the benefits of PV implementation in schools were analyzed and evaluated. Data analysis was applied to filter and normalize the data in order to identify the actual performance parameters. The findings of the study, based on solar irradiation collected, the performance of the module technology and the effectiveness of the automated cleaning systems, show that the performance ratio was maintained between 0.74 and 0.85. Furthermore, the minimum monthly energy yield of the PV systems was about 104 kW h/kW p . The annual average daily final yields of the PV systems in this study were 4.5 kW h/kW p /day. The results provided insight into the performance of CIGS grid-connected PV systems in Kuwait, and those data will be beneficial to the PV research community worldwide. School buildings, particularly for the rooftops, are a unique and important asset for urban PV system

  19. The Artemis workbench for system-level performance evaluation of embedded systems

    NARCIS (Netherlands)

    Pimentel, A.D.

    2008-01-01

    In this paper, we present an overview of the Artemis workbench, which provides modelling and simulation methods and tools for efficient performance evaluation and exploration of heterogeneous embedded multimedia systems. More specifically, we describe the Artemis system-level modelling methodology,

  20. Application of expert system to evaluating reactor water cleanup system performance

    International Nuclear Information System (INIS)

    Maeda, Katsuji; Nakamura, Masahiro; Nagasawa, Katsumi; Fushiki, Sumiyuki.

    1991-01-01

    Expert systems employing artificial intelligence (AI) have been developed for finding and elucidating causes of anomalies and malfunctions, presenting pertinent recommendation for countermeasures and for making precautionary diagnosis. On the other hand, further improvements in reliabilities for chemical control are required to promote BWR plant reliability and advancement. Especially, it is necessary to maintain the reactor water purity in high quality to minimize stress corrosion cracking (SCC) in primary cooling system, fuel performance degradation and radiation buildup. The reactor water quality is controlled by the reactor water cleanup (RWCU) system. So, it is very important to maintain the RWCU performance, in order to keep good reactor water quality. This paper describes an expert system used for evaluating RWCU system performance in BWR plants. (author)

  1. performance evaluation of sprinkler irrigation system at mambilla

    African Journals Online (AJOL)

    HOD

    ratio (DPR), irrigation productivity (IP), labour requirements and water quality. Standard procedure was ... The exchangeable cations analysis of Kakara irrigation ... Keywords: Tea, irrigation System, Performance Evaluation. 1. INTRODUCTION.

  2. A Proposed RTN Officer Performance Evaluation System

    Science.gov (United States)

    1989-12-01

    Taa& No. WokI Unlit Acca ~def 11¶. TITLE (biclde Securiy ClassifiCation) A PROPOSED ROYAL THAI NAVY OFIICER PERFORM NCE EVALUATION SYSTEM 12. PERSONAL...all aspects of performance into account , the commanding officer uses his opinion to decide who is "the best." There are no standard guidelines for...ftequently used in orgunsadozn as a bais for adminiardstive decisions such as employee promotion., tuufer, and allocation of financial reward; employee

  3. The transport performance evaluation system building of logistics enterprises

    Directory of Open Access Journals (Sweden)

    Xueli Wang

    2013-09-01

    Full Text Available Purpose: modern logistics has a significant role in today’s society, logistics cost accounts for 35% to 50% of total logistics costs, so it’s great significance to improve the transport performance of logistics enterprises. Design/methodology/approach: the authors select the transportation performance evaluation index of logistics enterprise, with the aid of the fuzzy theory and analytic hierarchy process (AHP, adopt the combining method of quantitative and qualitative analysis, construct the transport performance evaluation system of logistics enterprises. Findings: the choice of transport performance evaluation indicator system for Logistics enterprise is in a state of "high", which indicates the indicator selection is reasonable. Research limitations/implications: the selected indicators with experts’ subjective factors can not accurately quantify. Practical implications: it has important practical significance to promote the development of modern logistics enterprises and save social cost. Originality/value: current research methods mainly include the PDCA cycle model, key performance indicators (KPI and benchmarking method, principal component analysis method, etc. The authors for the first time with the aid of fuzzy theory and analytic hierarchy process (AHP, adopt the combining method of quantitative and qualitative research on transport performance problems.

  4. INTEGRATED WATER TREATMENT SYSTEM PERFORMANCE EVALUATION

    International Nuclear Information System (INIS)

    Sexton, R.A.; Meeuwsen, W.E.

    2009-01-01

    This document describes the results of an evaluation of the current Integrated Water Treatment System (IWTS) operation against design performance and a determination of short term and long term actions recommended to sustain IWTS performance. The KW IWTS was designed to treat basin water and maintain basin clarity during fuel retrieval, washing, and packaging activities in the KW Basin. The original design was based on a mission that was limited to handling of KW Basin fuel. The use of the IWTS was extended by the decision to transfer KE fuel to KW to be cleaned and packaged using KW systems. The use was further extended for the packaging of two more Multi-Canister Overpacks (MCOs) containing legacy fuel and scrap. Planning is now in place to clean and package Knock Out Pot (KOP) Material in MCOs using these same systems. Some washing of KOP material in the Primary Cleaning Machine (PCM) is currently being done to remove material that is too small or too large to be included in the KOP Material stream. These plans will require that the IWTS remain operational through a campaign of as many as 30 additional MCOs, and has an estimated completion date in 2012. Recent operation of the IWTS during washing of canisters of KOP Material has been impacted by low pressure readings at the inlet of the P4 Booster Pump. The system provides a low pressure alarm at 10 psig, and low-low pressure interlock at 5 psig. The response to these low readings has been to lower total system flow to between 301 and 315 gpm. In addition, the IWTS operator has been required to operate the system in manual mode and make frequent adjustments to the P4 booster pump speed during PCM washes. The preferred mode of operation is to establish a setpoint of 317 gpm for the P4 pump speed and run IWTS in semi-automatic mode. Based on hydraulic modeling compared to field data presented in this report, the low P4 inlet pressure is attributed to restrictions in the 2-inch KOP inlet hose and in the KOP itself

  5. Performance Evaluation of Irbene RT-16 Radio Telescope Receiving System

    Directory of Open Access Journals (Sweden)

    Bleiders M.

    2017-12-01

    Full Text Available In the present paper, recent measurement results of refurbished Irbene RT-16 radio telescope receiving system performance are presented. The aim of the research is to evaluate characteristics of RT-16, which will allow carrying out necessary amplitude calibration in both single dish and VLBI observations, to improve the performance of existing system as well as to monitor, control and compare performance if possible changes in the receiving system will occur in future. The evaluated receiving system is 16 m Cassegrain antenna equipped with a cryogenic receiver with frequency range from 4.5 to 8.8 GHz, which is divided into four sub-bands. Multiple calibration sessions have been carried out by observing stable astronomical sources with known flux density by using in-house made total power registration backend. First, pointing offset calibration has been carried out and pointing model coefficients calculated and applied. Then, amplitude calibration, namely antenna sensitivity, calibration diode equivalent flux density and gain curve measurements have been carried out by observing calibration sources at different antenna elevations at each of the receiver sub-bands. Beam patterns have also been evaluated at different frequency bands. As a whole, acquired data will serve as a reference point for comparison in future performance evaluation of RT-16.

  6. Application of the Performance Validation Tool for the Evaluation of NSSS Control System Performance

    International Nuclear Information System (INIS)

    Sohn, Suk-whun

    2011-01-01

    When a control system is supplied to nuclear power plant (NPP) under construction, static tests and dynamic tests are typically performed for evaluating its performance. The dynamic test is not realistic for validating the performance of the replaced hardware in operating NPPs because of potential risks and economic burden. We have, therefore, developed a performance validation tool which can evaluate the dynamic performances of the control system without undertaking real plant tests. The window-based nuclear plant performance analyzer (Win-NPA) is used as a virtual NPP in the developed tool and provides appropriate control loads to the target control system via hardwired cables in a manner that the interfaces are identical to the field wiring. The outputs from the control system are used as the simulation inputs of the plant model within the Win-NPA. With this closed-loop configuration, major transient events were simulated to check the performance of the implemented control system by comparing it with that of the control system model of the Win-NPA and that of the old hardware. The developed tool and the methodology were successfully applied to the hardware replacement project for Yonggwang (YGN) 3 and 4 feedwater control system (FWCS) in 2008. Several errors in the implemented control system were fixed through the performance validation tests and the operability tests. As a result, the control system of the YGN 3 and 4 has demonstrated an excellent control performance since then. On the basis of YGN 3 and 4 project experiences, we are performing a similar project in Ulchin (UCN) 3 and 4. This methodology can also be applied to other NPPs under construction as a tool for pre-operational dynamic tests. These performance tests before performing power ascension tests (PATs) are conducive to preventing unnecessary plant transients or unwanted reactor trips caused by hidden errors of control systems during PATs. (author)

  7. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    Science.gov (United States)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  8. Exploration of nuclear power enterprise 'STAR' management performance evaluation system

    International Nuclear Information System (INIS)

    Wang Sen

    2005-01-01

    From the angle of nuclear power enterprise safety culture, this essay breaks the connotations of the safety culture down to nine aspects (target management, safety management, quality management, housekeeping, cost control, authorization management, teamwork, communication and continued improvement), with each aspect divided into five levels of star class according to its own characteristics. A comparison is made between the actualities of the enterprise and star management performance evaluation system to find out the gap and identify ways of continued improvement to elevate the enterprise management level, thereby developing a standard system of conducting qualitative and quantitative evaluation to the management process. Apart from its evaluation function, this system provides a guideline on the work orientation, method, and steps to elevate work level and capability for the managers performing specific management actions. It is also a system of measuring and evaluating the executive force of the company's management and its employees. (author)

  9. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  10. PERFORMANCE EVALUATION OF PENSION FUNDS WITH FUZZY EXPERT SYSTEM

    Directory of Open Access Journals (Sweden)

    SERDAR KORUKOĞLU

    2013-06-01

    Full Text Available Financial rating and ranking firms often use linguistic instead of numerical values. When input data are mostly qualitative and are based on subjective knowledge of experts, the Fuzzy Set Theory provides a solid mathematical model to represent and handle these data. The aim of this study is developing a fuzzy expert model to evaluate the performance of the pension funds by using their risk and return values. The method is used for evaluating the performance of the randomly selected of twenty seven Turkish pension funds. The obtained results proved that the fuzzy expert system is appropriate and consistent for performance evaluation.

  11. Performance evaluation of public hospital information systems by the information system success model.

    Science.gov (United States)

    Cho, Kyoung Won; Bae, Sung-Kwon; Ryu, Ji-Hye; Kim, Kyeong Na; An, Chang-Ho; Chae, Young Moon

    2015-01-01

    This study was to evaluate the performance of the newly developed information system (IS) implemented on July 1, 2014 at three public hospitals in Korea. User satisfaction scores of twelve key performance indicators of six IS success factors based on the DeLone and McLean IS Success Model were utilized to evaluate IS performance before and after the newly developed system was introduced. All scores increased after system introduction except for the completeness of medical records and impact on the clinical environment. The relationships among six IS factors were also analyzed to identify the important factors influencing three IS success factors (Intention to Use, User Satisfaction, and Net Benefits). All relationships were significant except for the relationships among Service Quality, Intention to Use, and Net Benefits. The results suggest that hospitals should not only focus on systems and information quality; rather, they should also continuously improve service quality to improve user satisfaction and eventually reach full the potential of IS performance.

  12. Advanced transport systems analysis, modeling, and evaluation of performances

    CERN Document Server

    Janić, Milan

    2014-01-01

    This book provides a systematic analysis, modeling and evaluation of the performance of advanced transport systems. It offers an innovative approach by presenting a multidimensional examination of the performance of advanced transport systems and transport modes, useful for both theoretical and practical purposes. Advanced transport systems for the twenty-first century are characterized by the superiority of one or several of their infrastructural, technical/technological, operational, economic, environmental, social, and policy performances as compared to their conventional counterparts. The advanced transport systems considered include: Bus Rapid Transit (BRT) and Personal Rapid Transit (PRT) systems in urban area(s), electric and fuel cell passenger cars, high speed tilting trains, High Speed Rail (HSR), Trans Rapid Maglev (TRM), Evacuated Tube Transport system (ETT), advanced commercial subsonic and Supersonic Transport Aircraft (STA), conventionally- and Liquid Hydrogen (LH2)-fuelled commercial air trans...

  13. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  14. Experimental performance evaluation of two stack sampling systems in a plutonium facility

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.

    1992-04-01

    The evaluation of two routine stack sampling systems at the Z-Plant plutonium facility operated by Rockwell International for USERDA is part of a larger study, sponsored by Rockwell and conducted by Battelle, Pacific Northwest Laboratories, of gaseous effluent sampling systems. The gaseous effluent sampling systems evaluated are located at the main plant ventilation stack (291-Z-1) and at a vessel vent stack (296-Z-3). A preliminary report, which was a paper study issued in April 1976, identified many deficiencies in the existing sampling systems and made recommendations for corrective action. The objectives of this experimental evaluation of those sampling systems were as follows: Characterize the radioactive aerosols in the stack effluents; Develop a tracer aerosol technique for validating particulate effluent sampling system performance; Evaluate the performance of the existing routine sampling systems and their compliance with the sponsor's criteria; and Recommend corrective action where required. The tracer aerosol approach to sampler evaluation was chosen because the low concentrations of radioactive particulates in the effluents would otherwise require much longer sampling times and thus more time to complete this evaluation. The following report describes the sampling systems that are the subject of this study and then details the experiments performed. The results are then presented and discussed. Much of the raw and finished data are included in the appendices

  15. How Does Procedural Fairness Affect Performance Evaluation System Satisfaction? (Evidence from a UK Police Force

    Directory of Open Access Journals (Sweden)

    Sholihin Mahfud

    2013-12-01

    Full Text Available This paper investigates whether, and if so, how procedural fairness affects performance evaluation system satisfaction in a UK Police Force. Employing a survey method with samples of detective inspectors and detective chief inspectors with significant managerial responsibilities in a UK Police Force, this study finds that procedural fairness affects performance evaluation system satisfaction. Further analysis reveals that the effect of procedural fairness on performance evaluation system satisfaction is mediated by trust. This study provides empirical evidence on how procedural fairness affects performance evaluation system satisfaction. The results of this study may benefit the designer of performance evaluation systems in police organizations.

  16. A Domain Specific Language for Performance Evaluation of Medical Imaging Systems

    NARCIS (Netherlands)

    van den Berg, Freek; Remke, Anne Katharina Ingrid; Haverkort, Boudewijn R.H.M.; Turau, Volker; Kwiatkowska, Marta; Mangharam, Rahul; Weyer, Christoph

    2014-01-01

    We propose iDSL, a domain specific language and toolbox for performance evaluation of Medical Imaging Systems. iDSL provides transformations to MoDeST models, which are in turn converted into UPPAAL and discrete-event MODES models. This enables automated performance evaluation by means of model

  17. Performance evaluation of sprinkler irrigation system at Mambilla ...

    African Journals Online (AJOL)

    Variation in discharge can also be adjusted via use of uniform laterals, risers, and nozzles. This study further recommends an incorporation of a soil and water laboratory for the company to aid in monitoring the soil and water quality of the irrigation area. Keywords: Tea, irrigation System, Performance Evaluation ...

  18. Performance evaluation of Siemens E.Cam® Spect System at Korle ...

    African Journals Online (AJOL)

    Performance evaluation of Siemens E.Cam® Spect System at Korle-Bu Teaching Hospital (Ghana. ... The tests were performed according to National Electrical Manufac-turers Association protocols, and different measuring instruments and phantoms containing 99m-Tc were used. Extrinsic uniformity, System energy ...

  19. Performance evaluation and design of flight vehicle control systems

    CERN Document Server

    Falangas, Eric T

    2015-01-01

    This book will help students, control engineers and flight dynamics analysts to model and conduct sophisticated and systemic analyses of early flight vehicle designs controlled with multiple types of effectors and to design and evaluate new vehicle concepts in terms of satisfying mission and performance goals. Performance Evaluation and Design of Flight Vehicle Control Systems begins by creating a dynamic model of a generic flight vehicle that includes a range of elements from airplanes and launch vehicles to re-entry vehicles and spacecraft. The models may include dynamic effects dealing with structural flexibility, as well as dynamic coupling between structures and actuators, propellant sloshing, and aeroelasticity, and they are typically used for control analysis and design. The book shows how to efficiently combine different types of effectors together, such as aero-surfaces, TVC, throttling engines and RCS, to operate as a system by developing a mixing logic atrix. Methods of trimming a vehicle controll...

  20. Performance evaluation of various cryogenic energy storage systems

    International Nuclear Information System (INIS)

    Abdo, Rodrigo F.; Pedro, Hugo T.C.; Koury, Ricardo N.N.; Machado, Luiz; Coimbra, Carlos F.M.; Porto, Matheus P.

    2015-01-01

    This work compares various CES (cryogenic energy storage) systems as possible candidates to store energy from renewable sources. Mitigating solar and wind power variability and its direct effect on local grid stability are already a substantial technological bottleneck for increasing market penetration of these technologies. In this context, CES systems represent low-cost solutions for variability that can be used to set critical power ramp rates. We investigate the different thermodynamic and engineering constraints that affect the design of CES systems, presenting theoretical simulations, indicating that optimization is also needed to improve the cryogenic plant performance. - Highlights: • We assessed the performance of cryogenic energy storage systems. • We re-evaluated the Linde–Hampson cycle proposed by Chen. • We proposed the Claude and Collins cycles as alternatives for the Linde–Hampson cycle. • We concluded that Claude cycle is the best alternative for the simulated conditions.

  1. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  2. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  3. Establishment and application of performance evaluation model for collection and transportation system of municipal solid waste

    Institute of Scientific and Technical Information of China (English)

    彭绪亚; 林晓东; 贾传兴; 王渝昆; 黄媛媛

    2009-01-01

    On the basis of analyzing the typical waste collection and transportation mode,the evaluation index system for performance of the waste collection and transportation system was proposed with three grades,which related to six factors,such as economic evaluation,high efficient evaluation,environmental impact assessment,resource evaluation,evaluation of security and emergency,evaluation of management and society. With the performance evaluation theory,the performance evaluation model of waste collection and transportation system was constructed,which quantified the grading standard of index and determined the index weight in analytic hierarchy process (AHP). After evaluating the waste collection and transportation system of the main districts of Chongqing city,the results show that the it has an excellent performance evaluation grade with very high performance level of three indices involving evaluation of management and society,environmental impact assessment,evaluation of security and emergency and quite low performance level of two indices that include high efficient evaluation and economic evaluation.

  4. Performance Evaluation of Terrestrial Emergency Communication System in NPPs

    International Nuclear Information System (INIS)

    Son, Gwang Sub; Kim, Chang Hwoi; Kang, Hyun Gook

    2014-01-01

    The Fukushima accident induced by the great earthquake and tsunami reveals the vulnerability of I and C System. In the severe environment, the normal I and C system did not work properly and results in false information about the internal situation in NPP. Eventually the accident was not properly handled at the early stage. Therefore advanced emergency response system using a wireless channel is necessary to cope with the severe accident. In this paper, we introduce the ERS consisting of the HMS and MCS the ECS linking the HMS with MCS and the performance requirement of the ECS is analyzed. The ECS satisfying the requirement is designed conceptually and the performance of the ECS is evaluated through analysis and simulator. The terrestrial communication system is designed based on the IEEE 802.11. Analyzed performance results prove that the performance requirement can be sufficiently achieved. But if the scalability of data capacity is considered later, use of the advanced 802.11 standard such as 802.11n and multiple signal paths between the HMS and MCS are necessary

  5. Performance Evaluation of Terrestrial Emergency Communication System in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Son, Gwang Sub; Kim, Chang Hwoi; Kang, Hyun Gook [KAERI, Daejeon (Korea, Republic of)

    2014-08-15

    The Fukushima accident induced by the great earthquake and tsunami reveals the vulnerability of I and C System. In the severe environment, the normal I and C system did not work properly and results in false information about the internal situation in NPP. Eventually the accident was not properly handled at the early stage. Therefore advanced emergency response system using a wireless channel is necessary to cope with the severe accident. In this paper, we introduce the ERS consisting of the HMS and MCS the ECS linking the HMS with MCS and the performance requirement of the ECS is analyzed. The ECS satisfying the requirement is designed conceptually and the performance of the ECS is evaluated through analysis and simulator. The terrestrial communication system is designed based on the IEEE 802.11. Analyzed performance results prove that the performance requirement can be sufficiently achieved. But if the scalability of data capacity is considered later, use of the advanced 802.11 standard such as 802.11n and multiple signal paths between the HMS and MCS are necessary.

  6. Tracer gas evaluations of push-pull ventilation system performance.

    Science.gov (United States)

    Ojima, Jun

    2009-01-01

    A push-pull ventilation system is effective for hazardous material exhaustion. Although a push-pull ventilation system has advantages over a local exhaust hood, some laborious adjustments are required. The pertinence of the adjustments is uncertain because it is difficult to evaluate the performance of a push-pull ventilation system quantitatively. In this study, a measurement of the capture efficiency of a push-pull ventilation system was carried out by means of a tracer gas method. The capture efficiency decreased to 39.3-78.5% when blockage material, a dummy worker and a cross draft, were set in the ventilation zone, but the efficiency was 95.1-97.9% when the cross draft was stopped. The results suggest that the uniform flow of a push-pull ventilation system will detour a blockage and the performance of the system will not be reduced unless a cross draft disturbs the uniform flow.

  7. [Development of performance evaluation and management system on advanced schistosomiasis medical treatment].

    Science.gov (United States)

    Zhou, Xiao-Rong; Huang, Shui-Sheng; Gong, Xin-Guo; Cen, Li-Ping; Zhang, Cong; Zhu, Hong; Yang, Jun-Jing; Chen, Li

    2012-04-01

    To construct a performance evaluation and management system on advanced schistosomiasis medical treatment, and analyze and evaluate the work of the advanced schistosomiasis medical treatment over the years. By applying the database management technique and C++ programming technique, we inputted the information of the advanced schistosomiasis cases into the system, and comprehensively evaluated the work of the advanced schistosomiasis medical treatment through the cost-effect analysis, cost-effectiveness analysis, and cost-benefit analysis. We made a set of software formula about cost-effect analysis, cost-effectiveness analysis, and cost-benefit analysis. This system had many features such as clear building, easy to operate, friendly surface, convenient information input and information search. It could benefit the performance evaluation of the province's advanced schistosomiasis medical treatment work. This system can satisfy the current needs of advanced schistosomiasis medical treatment work and can be easy to be widely used.

  8. Development of design window evaluation and display system. 1. System development and performance confirmation

    International Nuclear Information System (INIS)

    Muramatsu, Toshiharu; Yamaguchi, Akira

    2003-07-01

    Purpose: The work was performed to develop a design window evaluation and display system for the purpose of obtaining the effects of various design parameters on the typical thermal hydraulic issues resulting from a use of various kind of working fluid etc. easily. Method: The function of the system were 'confirmation of design margin' of the present design, 'confirmation of the affected design zone' when a designer changed some design parameter, and search for an design improvement' for design optimization. The system was developed using existing soft wares on PC and the database relating analytical results of typical thermal hydraulic issues provided by separate work. Results: (1) System design: In order to develop a design window evaluation and display system, 'numerical analysis unit', 'statistical analysis unit', 'MMI unit', 'optimization unit' were designed based on the result of selected optimization procedure and display visualization. Further, total system design was performed combining these units. Typical thermal hydraulic issues to be considered are upper plenum thermal hydraulics, thermal stratification, free surface sloshing, flow-induced vibration of a heat exchanger and thermal striping in the T-junction piping systems. (2) Development of prototype system and a functional check: A prototype system of a design window evaluation and display system was developed and the functions were confirmed as was planned. (author)

  9. Performance evaluation of a retrofit digital detector-based mammography system.

    Science.gov (United States)

    Marshall, Nicholas W; van Ongeval, Chantal; Bosmans, Hilde

    2016-02-01

    A retrofit flat panel detector was integrated with a GE DMR+ analog mammography system and characterized using detective quantum efficiency (DQE). Technical system performance was evaluated using the European Guidelines protocol, followed by a limited evaluation of clinical image quality for 20 cases using image quality criteria in the European Guidelines. Optimal anode/filter selections were established using signal difference-to-noise ratio measurements. Only small differences in peak DQE were seen between the three anode/filter settings, with an average value of 0.53. For poly(methyl methacrylate) (PMMA) thicknesses above 60 mm, the Rh/Rh setting was the optimal anode/filter setting. The system required a mean glandular dose of 0.54 mGy at 30 kV Rh/Rh to reach the Acceptable gold thickness limit for 0.1 mm details. Imaging performance of the retrofit unit with the GE DMR+ is notably better than of powder based computed radiography systems and is comparable to current flat panel FFDM systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Information systems performance evaluation, introducing a two-level technique: Case study call centers

    Directory of Open Access Journals (Sweden)

    Hesham A. Baraka

    2015-03-01

    The objective of this paper was to introduce a new technique that can support decision makers in the call centers industry to evaluate, and analyze the performance of call centers. The technique presented is derived from the research done on measuring the success or failure of information systems. Two models are mainly adopted namely: the Delone and Mclean model first introduced in 1992 and the Design Reality Gap model introduced by Heeks in 2002. Two indices are defined to calculate the performance of the call center; the success index and the Gap Index. An evaluation tool has been developed to allow call centers managers to evaluate the performance of their call centers in a systematic analytical approach; the tool was applied on 4 call centers from different areas, simple applications such as food ordering, marketing, and sales, technical support systems, to more real time services such as the example of emergency control systems. Results showed the importance of using information systems models to evaluate complex systems as call centers. The models used allow identifying the dimensions for the call centers that are facing challenges, together with an identification of the individual indicators in these dimensions that are causing the poor performance of the call center.

  11. Performances of different digital mammography imaging systems: Evaluation and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)]. E-mail: giuseppina.bisogni@pi.infn.it; Bulajic, D. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); International Centre for Theoretical Physics, Trieste (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)

    2005-07-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems.

  12. Performances of different digital mammography imaging systems: Evaluation and comparison

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Bulajic, D.; Delogu, P.; Fantacci, M.E.; Novelli, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.

    2005-01-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems

  13. Performance evaluation of railway blocking system based on markov chain and queuing theory

    Science.gov (United States)

    Guo, Jin; Chen, Hongxia; Yang, Yang

    2005-12-01

    Railway blocking system is the system with the high demanding of real-time performance. Firstly, the tasks and the time limits, which had to be handled for the blocking system, were introduced. The FCFS and the Markov chain were used to set the model for it. By analyzing the performance of the system with the FCFS model found out that it was not satisfied to the real-time performance. Secondly, NPPR model to evaluate the software real-time performance of the blocking processor was proposed. By evaluation, analysis and comparison, the results indicate that the NPPR model is prevail over the model of (M/M/1): (N/N/FCFS) in real-time performance. And the priorities of the tasks in the system should be given according to their time limit. With the principle of (M/M/1): (N/N/NPPR), if the priority was given to the tasks properly, the satisfied real-time performance will be gotten. The models were tested in forms software and the satisfied result has been gotten in practice.

  14. A Step beyond Univision Evaluation: Using a Systems Model of Performance Improvement.

    Science.gov (United States)

    Sleezer, Catherine M.; Zhang, Jiping; Gradous, Deane B.; Maile, Craig

    1999-01-01

    Examines three views of performance improvement--scientific management, instructional design, and systems thinking--each providing a unique view of performance improvement and specific roles for evaluation. Provides an integrated definition of performance and a synthesis model that encompasses the three views. (AEF)

  15. Multiple performance measures are needed to evaluate triage systems in the emergency department.

    Science.gov (United States)

    Zachariasse, Joany M; Nieboer, Daan; Oostenbrink, Rianne; Moll, Henriëtte A; Steyerberg, Ewout W

    2018-02-01

    Emergency department triage systems can be considered prediction rules with an ordinal outcome, where different directions of misclassification have different clinical consequences. We evaluated strategies to compare the performance of triage systems and aimed to propose a set of performance measures that should be used in future studies. We identified performance measures based on literature review and expert knowledge. Their properties are illustrated in a case study evaluating two triage modifications in a cohort of 14,485 pediatric emergency department visits. Strengths and weaknesses of the performance measures were systematically appraised. Commonly reported performance measures are measures of statistical association (34/60 studies) and diagnostic accuracy (17/60 studies). The case study illustrates that none of the performance measures fulfills all criteria for triage evaluation. Decision curves are the performance measures with the most attractive features but require dichotomization. In addition, paired diagnostic accuracy measures can be recommended for dichotomized analysis, and the triage-weighted kappa and Nagelkerke's R 2 for ordinal analyses. Other performance measures provide limited additional information. When comparing modifications of triage systems, decision curves and diagnostic accuracy measures should be used in a dichotomized analysis, and the triage-weighted kappa and Nagelkerke's R 2 in an ordinal approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Introducing the Evaluation Tools for HSE Management System Performance Using Balanced Score Card Model

    Directory of Open Access Journals (Sweden)

    Ali Mohammadi

    2016-12-01

    Full Text Available Background: The performance of the HSE units has various dimensions Leading to different performances. Thus, any industry should be capable of evaluating these systems. The aim of this study was to design a standard questionnaire in the field of performance evaluation of HSE management system employing Balanced Score Card model. Methods: In this study we, first determined the criteria to be evaluated in the framework of Balanced Score Card model based on the objectives and strategies of HSE Management System and existing standards, and then designed questions on every criterion. We used content validity and Cronbach's Alpha to determine the reliability and validity of the questionnaire. Results: The primary questionnaire was comprised of 126 questions some of which were omitted regarding the results obtained from the CVR and CVI values. We obtained the CVI average of environmental dimension to be 0.75 and its CVI average 0.71. Conclusion: With respect to the results of the reliability and validity of this questionnaire,and its standardized design we can suggest using it for evaluation of HSE management system performance in organizations and industries with the mentioned system.

  17. Clinical performance of a glass ionomer restorative system: a 6-year evaluation.

    Science.gov (United States)

    Gurgan, Sevil; Kutuk, Zeynep Bilge; Ergin, Esra; Oztas, Sema Seval; Cakir, Filiz Yalcin

    2017-09-01

    The aim of this study is to evaluate the long-term clinical performance of a glass ionomer (GI) restorative system in the restoration of posterior teeth compared with a micro-filled hybrid posterior composite. A total of 140 (80 Cl1 and 60 Cl2) lesions in 59 patients were restored with a GI system (Equia) or a micro hybrid composite (Gradia Direct). Restorations were evaluated at baseline and yearly during 6 years according to the modified-USPHS criteria. Negative replicas at each recall were observed under SEM to evaluate surface characteristics. Data were analyzed with Cohcran's Q and McNemar's tests (p evaluated in 47 patients with a recall rate of 79.6% at 6 years. Significant differences were found in marginal adaptation and marginal discoloration for both restorative materials for Cl1 and Cl2 restorations (p  0.05). A significant decrease in color match was observed in Equia restorations (p performance after 6 years. SEM evaluations were in accordance with the clinical findings. Both materials showed a good clinical performance for the restoration of posterior teeth during the 6-year evaluation. The clinical effectiveness of Equia and Gradia Direct Posterior was acceptable in Cl1 and Cl2 cavities subsequent to 6-year evaluation.

  18. An integrated methodology for the dynamic performance and reliability evaluation of fault-tolerant systems

    International Nuclear Information System (INIS)

    Dominguez-Garcia, Alejandro D.; Kassakian, John G.; Schindall, Joel E.; Zinchuk, Jeffrey J.

    2008-01-01

    We propose an integrated methodology for the reliability and dynamic performance analysis of fault-tolerant systems. This methodology uses a behavioral model of the system dynamics, similar to the ones used by control engineers to design the control system, but also incorporates artifacts to model the failure behavior of each component. These artifacts include component failure modes (and associated failure rates) and how those failure modes affect the dynamic behavior of the component. The methodology bases the system evaluation on the analysis of the dynamics of the different configurations the system can reach after component failures occur. For each of the possible system configurations, a performance evaluation of its dynamic behavior is carried out to check whether its properties, e.g., accuracy, overshoot, or settling time, which are called performance metrics, meet system requirements. Markov chains are used to model the stochastic process associated with the different configurations that a system can adopt when failures occur. This methodology not only enables an integrated framework for evaluating dynamic performance and reliability of fault-tolerant systems, but also enables a method for guiding the system design process, and further optimization. To illustrate the methodology, we present a case-study of a lateral-directional flight control system for a fighter aircraft

  19. Performance Evaluation of Bidding-Based Multi-Agent Scheduling Algorithms for Manufacturing Systems

    Directory of Open Access Journals (Sweden)

    Antonio Gordillo

    2014-10-01

    Full Text Available Artificial Intelligence techniques have being applied to many problems in manufacturing systems in recent years. In the specific field of manufacturing scheduling many studies have been published trying to cope with the complexity of the manufacturing environment. One of the most utilized approaches is (multi agent-based scheduling. Nevertheless, despite the large list of studies reported in this field, there is no resource or scientific study on the performance measure of this type of approach under very common and critical execution situations. This paper focuses on multi-agent systems (MAS based algorithms for task allocation, particularly in manufacturing applications. The goal is to provide a mechanism to measure the performance of agent-based scheduling approaches for manufacturing systems under key critical situations such as: dynamic environment, rescheduling, and priority change. With this mechanism it will be possible to simulate critical situations and to stress the system in order to measure the performance of a given agent-based scheduling method. The proposed mechanism is a pioneering approach for performance evaluation of bidding-based MAS approaches for manufacturing scheduling. The proposed method and evaluation methodology can be used to run tests in different manufacturing floors since it is independent of the workshop configuration. Moreover, the evaluation results presented in this paper show the key factors and scenarios that most affect the market-like MAS approaches for manufacturing scheduling.

  20. 48 CFR 36.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Performance evaluation. 36.604 Section 36.604 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION SPECIAL... Performance evaluation. See 42.1502(f) for the requirements for preparing past performance evaluations for...

  1. Aging evaluation of active components by using performance evaluation

    International Nuclear Information System (INIS)

    Jung, S. K.; Jin, T. E.; Kim, J. S.; Jung, I. S.; Kim, T. R.

    2003-01-01

    Risk analysis and performance evaluation methodology were applied to the aging evaluation of active components in the periodic safety review of Wolsung unit 1. We conclude that evaluation of performance is more effective to discriminate the aging degradation of active component than the evaluation of aging mechanism. It is essential to analyze the common cause failures of low performance components to evaluate the properness of present maintenance system. Past 10 years failure history is used for establishing the performance criteria. Past 2 years failure history is used for the evaluating the recent performance condition. We analyze the failure mode of the components to improve the maintenance system. Performance evaluation methodology is useful for the quantitative evaluation of aging degradation of active components. Analysis on the repeated failures can be useful for the feedback to maintenance plan and interval

  2. ASPECT (Automated System-level Performance Evaluation and Characterization Tool), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — SSCI has developed a suite of SAA tools and an analysis capability referred to as ASPECT (Automated System-level Performance Evaluation and Characterization Tool)....

  3. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  4. ACS sampling system: design, implementation, and performance evaluation

    Science.gov (United States)

    Di Marcantonio, Paolo; Cirami, Roberto; Chiozzi, Gianluca

    2004-09-01

    By means of ACS (ALMA Common Software) framework we designed and implemented a sampling system which allows sampling of every Characteristic Component Property with a specific, user-defined, sustained frequency limited only by the hardware. Collected data are sent to various clients (one or more Java plotting widgets, a dedicated GUI or a COTS application) using the ACS/CORBA Notification Channel. The data transport is optimized: samples are cached locally and sent in packets with a lower and user-defined frequency to keep network load under control. Simultaneous sampling of the Properties of different Components is also possible. Together with the design and implementation issues we present the performance of the sampling system evaluated on two different platforms: on a VME based system using VxWorks RTOS (currently adopted by ALMA) and on a PC/104+ embedded platform using Red Hat 9 Linux operating system. The PC/104+ solution offers, as an alternative, a low cost PC compatible hardware environment with free and open operating system.

  5. Key Performance Indicators Evaluation and Performance Measurement in Dry Port-Seaport System: A Multi Criteria Approach

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Dry port-seaport services are key elements of a multimodal transport. They represent the needed infrastructure for its development. In this case, evaluating and improving their performance is necessary to achieve international competitiveness. The purpose of this paper is to develop a new model of performance measurement for the dry port-seaport system. To this aim, we have consolidated available researches and existing studies in order to identify and develop our proposed model framework. In this paper, a multi-criteria hierarchical model framework using MACBETH for dry port-seaport system has been developed. This framework can be used by managers at different levels of the system. The proposed model has been developed by exploring measurement gaps in multimodal transport field and by discovering prospective options from this area. The results and the methodology are practical. We obtain the global performance level of our involved system using our methodology, which can help managers in taken decisions and increase global performance of this system.

  6. Evaluating trauma center structural performance: The experience of a Canadian provincial trauma system

    Directory of Open Access Journals (Sweden)

    Lynne Moore

    2013-01-01

    Full Text Available Background: Indicators of structure, process, and outcome are required to evaluate the performance of trauma centers to improve the quality and efficiency of care. While periodic external accreditation visits are part of most trauma systems, a quantitative indicator of structural performance has yet to be proposed. The objective of this study was to develop and validate a trauma center structural performance indicator using accreditation report data. Materials and Methods: Analyses were based on accreditation reports completed during on-site visits in the Quebec trauma system (1994-2005. Qualitative report data was retrospectively transposed onto an evaluation grid and the weighted average of grid items was used to quantify performance. The indicator of structural performance was evaluated in terms of test-retest reliability (kappa statistic, discrimination between centers (coefficient of variation, content validity (correlation with accreditation decision, designation level, and patient volume and forecasting (correlation between visits performed in 1994-1999 and 1998-2005. Results: Kappa statistics were >0.8 for 66 of the 73 (90% grid items. Mean structural performance score over 59 trauma centers was 47.4 (95% CI: 43.6-51.1. Two centers were flagged as outliers and the coefficient of variation was 31.2% (95% CI: 25.5% to 37.6%, showing good discrimination. Correlation coefficients of associations with accreditation decision, designation level, and volume were all statistically significant (r = 0.61, -0.40, and 0.24, respectively. No correlation was observed over time (r = 0.03. Conclusion: This study demonstrates the feasibility of quantifying trauma center structural performance using accreditation reports. The proposed performance indicator shows good test-retest reliability, between-center discrimination, and construct validity. The observed variability in structural performance across centers and over-time underlines the importance of

  7. Evaluation of Subjective and Objective Performance Metrics for Haptically Controlled Robotic Systems

    Directory of Open Access Journals (Sweden)

    Cong Dung Pham

    2014-07-01

    Full Text Available This paper studies in detail how different evaluation methods perform when it comes to describing the performance of haptically controlled mobile manipulators. Particularly, we investigate how well subjective metrics perform compared to objective metrics. To find the best metrics to describe the performance of a control scheme is challenging when human operators are involved; how the user perceives the performance of the controller does not necessarily correspond to the directly measurable metrics normally used in controller evaluation. It is therefore important to study whether there is any correspondence between how the user perceives the performance of a controller, and how it performs in terms of directly measurable metrics such as the time used to perform a task, number of errors, accuracy, and so on. To perform these tests we choose a system that consists of a mobile manipulator that is controlled by an operator through a haptic device. This is a good system for studying different performance metrics as the performance can be determined by subjective metrics based on feedback from the users, and also as objective and directly measurable metrics. The system consists of a robotic arm which provides for interaction and manipulation, which is mounted on a mobile base which extends the workspace of the arm. The operator thus needs to perform both interaction and locomotion using a single haptic device. While the position of the on-board camera is determined by the base motion, the principal control objective is the motion of the manipulator arm. This calls for intelligent control allocation between the base and the manipulator arm in order to obtain intuitive control of both the camera and the arm. We implement three different approaches to the control allocation problem, i.e., whether the vehicle or manipulator arm actuation is applied to generate the desired motion. The performance of the different control schemes is evaluated, and our

  8. A study on regional comprehensive performance evaluation indicator system of rational use of drugs

    Directory of Open Access Journals (Sweden)

    Sun Tongda

    2017-01-01

    Full Text Available The current research presents the design of a 4-degree-3-level performance evaluation indicator system of rational use of drugs for health care institutions accord with the Balanced Score Card (BSC method. Financial index, patient index, professional process index, and development and blazing new trials index are adopted in the light of scientific, guiding, operable and generalizable principles. The index weight is based on the analytic hierarchy process, and comprehensive performance evaluation indicators are calculated by a linear integrated weighting method. Its practical application in 21 state-run health care institutions in Ningbo, from 2008 to 2012, has arrived at the finding that the comprehensive performance evaluation indicator system offers a scientific, practical and effective performance management quantification and is thus worth popularizing.

  9. Performance Evaluation of UML2-Modeled Embedded Streaming Applications with System-Level Simulation

    Directory of Open Access Journals (Sweden)

    Arpinen Tero

    2009-01-01

    Full Text Available This article presents an efficient method to capture abstract performance model of streaming data real-time embedded systems (RTESs. Unified Modeling Language version 2 (UML2 is used for the performance modeling and as a front-end for a tool framework that enables simulation-based performance evaluation and design-space exploration. The adopted application meta-model in UML resembles the Kahn Process Network (KPN model and it is targeted at simulation-based performance evaluation. The application workload modeling is done using UML2 activity diagrams, and platform is described with structural UML2 diagrams and model elements. These concepts are defined using a subset of the profile for Modeling and Analysis of Realtime and Embedded (MARTE systems from OMG and custom stereotype extensions. The goal of the performance modeling and simulation is to achieve early estimates on task response times, processing element, memory, and on-chip network utilizations, among other information that is used for design-space exploration. As a case study, a video codec application on multiple processors is modeled, evaluated, and explored. In comparison to related work, this is the first proposal that defines transformation between UML activity diagrams and streaming data application workload meta models and successfully adopts it for RTES performance evaluation.

  10. 48 CFR 436.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Performance evaluation... Performance evaluation. Preparation of performance evaluation reports. (a) In addition to the requirements of FAR 36.604, performance evaluation reports shall be prepared for indefinite-delivery type contracts...

  11. Evaluating performance of MARTe as a real-time framework for feed-back control system at tokamak device

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Sangwon; Lee, Woongryol; Lee, Taegu; Park, Mikyung; Lee, Sangil [National Fusion Research Institute (NFRI), Gwahangno 169-148, Yuseong-Gu, Daejeon 305-806 (Korea, Republic of); Neto, André C. [Associação EURATOM/IST, Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, P-1049-001 Lisboa (Portugal); Wallander, Anders [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Kim, Young-Kuk, E-mail: ykim@cnu.ac.kr [Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2013-10-15

    Highlights: •We measured the performance of MARTe by measuring response time and jitter. •We compared the performance of application with and without MARTe. •We compared the performance of MARTe application on different O/Ss. -- Abstract: The Korea Super conducting Tokamak Advanced Research (KSTAR) is performing the task of “Demonstration and Evaluation of ITER CODAC Technologies at KSTAR” whose objective is the evaluation of real-time technologies for decision making on real-time operating systems (RTOS), real-time frameworks and 10 GbE networks. In this task, the Multi-threaded Application Real-Time executor (MARTe) has been evaluated as a real-time framework for real-time feedback control system. The performance of MARTe has been verified by measuring response time and jitter in a path of feedback control from an analog input of a monitoring system to an analog output of an actuator system. In addition, the evaluation has been performed in terms of applicability of MARTe and its performance depending on types of operating system and tuning of CPU affinity and priority. This paper describes the overview of MARTe as a real-time framework, the results of evaluation performance and its implementation.

  12. Evaluating performance of MARTe as a real-time framework for feed-back control system at tokamak device

    International Nuclear Information System (INIS)

    Yun, Sangwon; Lee, Woongryol; Lee, Taegu; Park, Mikyung; Lee, Sangil; Neto, André C.; Wallander, Anders; Kim, Young-Kuk

    2013-01-01

    Highlights: •We measured the performance of MARTe by measuring response time and jitter. •We compared the performance of application with and without MARTe. •We compared the performance of MARTe application on different O/Ss. -- Abstract: The Korea Super conducting Tokamak Advanced Research (KSTAR) is performing the task of “Demonstration and Evaluation of ITER CODAC Technologies at KSTAR” whose objective is the evaluation of real-time technologies for decision making on real-time operating systems (RTOS), real-time frameworks and 10 GbE networks. In this task, the Multi-threaded Application Real-Time executor (MARTe) has been evaluated as a real-time framework for real-time feedback control system. The performance of MARTe has been verified by measuring response time and jitter in a path of feedback control from an analog input of a monitoring system to an analog output of an actuator system. In addition, the evaluation has been performed in terms of applicability of MARTe and its performance depending on types of operating system and tuning of CPU affinity and priority. This paper describes the overview of MARTe as a real-time framework, the results of evaluation performance and its implementation

  13. A Correlated Model for Evaluating Performance and Energy of Cloud System Given System Reliability

    Directory of Open Access Journals (Sweden)

    Hongli Zhang

    2015-01-01

    Full Text Available The serious issue of energy consumption for high performance computing systems has attracted much attention. Performance and energy-saving have become important measures of a computing system. In the cloud computing environment, the systems usually allocate various resources (such as CPU, Memory, Storage, etc. on multiple virtual machines (VMs for executing tasks. Therefore, the problem of resource allocation for running VMs should have significant influence on both system performance and energy consumption. For different processor utilizations assigned to the VM, there exists the tradeoff between energy consumption and task completion time when a given task is executed by the VMs. Moreover, the hardware failure, software failure and restoration characteristics also have obvious influences on overall performance and energy. In this paper, a correlated model is built to analyze both performance and energy in the VM execution environment given the reliability restriction, and an optimization model is presented to derive the most effective solution of processor utilization for the VM. Then, the tradeoff between energy-saving and task completion time is studied and balanced when the VMs execute given tasks. Numerical examples are illustrated to build the performance-energy correlated model and evaluate the expected values of task completion time and consumed energy.

  14. Evaluating Nonclinical Performance of the Academic Pathologist: A Comprehensive, Scalable, and Flexible System for Leadership Use.

    Science.gov (United States)

    Wiles, Austin Blackburn; Idowu, Michael O; Clevenger, Charles V; Powers, Celeste N

    2018-01-01

    Academic pathologists perform clinical duties, as well as valuable nonclinical activities. Nonclinical activities may consist of research, teaching, and administrative management among many other important tasks. While clinical duties have many clear metrics to measure productivity, like the relative value units of Medicare reimbursement, nonclinical performance is often difficult to measure. Despite the difficulty of evaluating nonclinical activities, nonclinical productivity is used to determine promotion, funding, and inform professional evaluations of performance. In order to better evaluate the important nonclinical performance of academic pathologists, we present an evaluation system for leadership use. This system uses a Microsoft Excel workbook to provide academic pathologist respondents and reviewing leadership a transparent, easy-to-complete system that is both flexible and scalable. This system provides real-time feedback to academic pathologist respondents and a clear executive summary that allows for focused guidance of the respondent. This system may be adapted to fit practices of varying size, measure performance differently based on years of experience, and can work with many different institutional values.

  15. ANALYTIC NETWORK PROCESS AND BALANCED SCORECARD APPLIED TO THE PERFORMANCE EVALUATION OF PUBLIC HEALTH SYSTEMS

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Reis dos Santos

    2015-08-01

    Full Text Available The performance of public health systems is an issue of great concern. After all, to assure people's quality of life, public health systems need different kinds of resources. Balanced Scorecard provides a multi-dimensional evaluation framework. This paper presents the application of the Analytic Network Process and Balanced Scorecard in the performance evaluation of a public health system in a typical medium-sized Southeastern town in Brazil.

  16. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    Science.gov (United States)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  17. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  18. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  19. Performance evaluation model of a pilot food waste collection system in Suzhou City, China.

    Science.gov (United States)

    Wen, Zongguo; Wang, Yuanjia; De Clercq, Djavan

    2015-05-01

    This paper analyses the food waste collection and transportation (C&T) system in a pilot project in Suzhou by using a novel performance evaluation method. The method employed to conduct this analysis involves a unified performance evaluation index containing qualitative and quantitative indicators applied to data from Suzhou City. Two major inefficiencies were identified: a) low system efficiency due to insufficient processing capacity of commercial food waste facilities; and b) low waste resource utilization due to low efficiency of manual sorting. The performance evaluation indicated that the pilot project collection system's strong points included strong economics, low environmental impact and low social impact. This study also shows that Suzhou's integrated system has developed a comprehensive body of laws and clarified regulatory responsibilities for each of the various government departments to solve the problems of commercial food waste management. Based on Suzhou's experience, perspectives and lessons can be drawn for other cities and areas where food waste management systems are in the planning stage, or are encountering operational problems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Development of a system for automatic control and performance evaluation of shutoff units in HANARO

    International Nuclear Information System (INIS)

    Jeong, Y. H.; Joe, Y. G.; Choi, Y. S.; Woo, J. S.

    2003-01-01

    The function of the shutoff units is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes the development of a system for automatic control and performance evaluation of shutoff units. The system automatically drives the shutoff unit with a specified operation cycle and records the performance of the drive mechanism in graphs and data. Also, it records the operating parameters of the shutoff unit and test facility. The characteristic of the developed system was evaluated to compare with that being use in the HANARO reactor. The system will be used for the performance and endurance tests in the test facility. Hereafter, the system will efficiently be used for the normal operation and the periodical drop performance tests of shutoff units in HANARO

  1. Performance evaluation of Siemens E.CAM(R) SPECT system at Korle-Bu Teaching Hospital (Ghana)

    International Nuclear Information System (INIS)

    Sosu, E.K.; Hasford, F.; Amuasi, J.H.

    2011-01-01

    Performance evaluation tests on Siemens e.cam(R) Signature Series Single Photon Emission Computed Tomography (SPECT)System at Korle-Bu Teaching Hospital (Ghana) were conducted for compliance with Manufacturer's specifications and user's requirements. The tests were performed according to National Electrical Manufacturer's Association protocols, and different measuring instruments and phantoms containing 99m-Tc were used. Extrinsic uniformity, system energy resolution, system spatial resolution (without scattering), detector shield leakage and system planar sensitivity were evaluated. The system energy resolution measured was 9.38 % as against manufacturer's specification of ≤ 9.9 %, Planar sensitivity value measured was 232.92 c/min/mCi while manufacturers' specification was 202 c/min/mCi, and detector shield leakage values measured were 0.001 %, 0.002 % and 0.025 % against an accepted value of < 1 %. The performance evaluation confirmed that the system met requirements for clinical nuclear medicine imaging, and the values could be used as database for future quality control measurements. (au)

  2. Solar energy system performance evaluation report for IBM System 4 at Clinton, Mississippi

    Science.gov (United States)

    1980-07-01

    The IBM System 4 Solar Energy System is described and evaluated. The system was designed to provide 35 percent of the space heating and 63 percent of the domestic hot water preheating for a single family residence located within the United States. The system consists of 259 square feet of flat plate air collectors, a rock thermal storage containing 5 1/2 ton of rock, heat exchangers, blowers, a 52 gallon preheat tank, controls, and associated plumbing. In general, the performance of the system did not meet design expectations, since the overall design solar fraction was 48 percent and the measured value was 32 percent. Although the measured space heating solar fraction at 32 percent did agree favorably with the design space heating solar fraction at 35 percent, the hot water measured solar fraction at 33 percent did not agree favorably with the design hot water solar fraction of 63 percent. In particular collector array air leakage, dust covered collectors, abnormal hot water demand, and the preheat tank by pass valve problem are main reasons for the lower performance.

  3. 48 CFR 2936.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Performance evaluation... Performance evaluation. (a) The HCA must establish procedures to evaluate architect-engineer contractor... reports must be made using Standard Form 1421, Performance Evaluation (Architect-Engineer) as prescribed...

  4. Influence of socioeconomic status on trauma center performance evaluations in a Canadian trauma system.

    Science.gov (United States)

    Moore, Lynne; Turgeon, Alexis F; Sirois, Marie-Josée; Murat, Valérie; Lavoie, André

    2011-09-01

    Trauma center performance evaluations generally include adjustment for injury severity, age, and comorbidity. However, disparities across trauma centers may be due to other differences in source populations that are not accounted for, such as socioeconomic status (SES). We aimed to evaluate whether SES influences trauma center performance evaluations in an inclusive trauma system with universal access to health care. The study was based on data collected between 1999 and 2006 in a Canadian trauma system. Patient SES was quantified using an ecologic index of social and material deprivation. Performance evaluations were based on mortality adjusted using the Trauma Risk Adjustment Model. Agreement between performance results with and without additional adjustment for SES was evaluated with correlation coefficients. The study sample comprised a total of 71,784 patients from 48 trauma centers, including 3,828 deaths within 30 days (4.5%) and 5,549 deaths within 6 months (7.7%). The proportion of patients in the highest quintile of social and material deprivation varied from 3% to 43% and from 11% to 90% across hospitals, respectively. The correlation between performance results with or without adjustment for SES was almost perfect (r = 0.997; 95% CI 0.995-0.998) and the same hospital outliers were identified. We observed an important variation in SES across trauma centers but no change in risk-adjusted mortality estimates when SES was added to adjustment models. Results suggest that after adjustment for injury severity, age, comorbidity, and transfer status, disparities in SES across trauma center source populations do not influence trauma center performance evaluations in a system offering universal health coverage. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Spearfish High School, Sparfish, South Dakota solar energy system performance evaluation, September 1980-June 1981

    Energy Technology Data Exchange (ETDEWEB)

    Howard, B.D.

    1981-01-01

    Spearfish High School in South Dakota contains 43,000 square feet of conditioned space. Its active solar energy system is designed to supply 57% of the space heating and 50% of the hot water demand. The system is equipped with 8034 square feet of flat plate collectors, 4017 cubic feet of rock bin sensible heat storage, and auxiliary equipment including 8 heat pumps, 6 of which are solar supplied and instrumented, air conditioning units, and natural-gas-fired boilers. Performance data are given for the system including the solar fraction, solar savings ratio, conventional fuel savings, system performance factor and solar system coefficient of performance. Insolation, solar energy utilization and operation data are also given. The performance of the collector, storage, domestic hot water and space heating subsystems, the operating energy, energy savings, and weather conditions are also evaluated. Appended are a system description, performance evaluation techniques and equations, site history, long-term weather data, sensor technology, and typical monthly data. (LEW)

  6. Fuzzy comprehensive evaluation for grid-connected performance of integrated distributed PV-ES systems

    Science.gov (United States)

    Lv, Z. H.; Li, Q.; Huang, R. W.; Liu, H. M.; Liu, D.

    2016-08-01

    Based on the discussion about topology structure of integrated distributed photovoltaic (PV) power generation system and energy storage (ES) in single or mixed type, this paper focuses on analyzing grid-connected performance of integrated distributed photovoltaic and energy storage (PV-ES) systems, and proposes a comprehensive evaluation index system. Then a multi-level fuzzy comprehensive evaluation method based on grey correlation degree is proposed, and the calculations for weight matrix and fuzzy matrix are presented step by step. Finally, a distributed integrated PV-ES power generation system connected to a 380 V low voltage distribution network is taken as the example, and some suggestions are made based on the evaluation results.

  7. Measurement-Based Evaluation of Installed Filtration System Performance in Single-Family Homes

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu Rengie; Singer, Brett C.

    2014-04-03

    This guide discusses important study design issues to consider when conducting an on-site evaluation of filtration system performance. The two most important dichotomies to consider in developing a study protocol are (1) whether systems are being evaluated in occupied or unoccupied homes and (2) whether different systems are being compared in the same homes or if the comparison is between systems installed in different homes. This document provides perspective and recommendations about a suite of implementation issues including the choice of particle measurement devices, selection of sampling locations, ways to control and/or monitor factors and processes that can impact particle concentrations, and data analysis approaches.

  8. 48 CFR 236.604 - Performance evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Performance evaluation... Architect-Engineer Services 236.604 Performance evaluation. (a) Preparation of performance reports. Use DD Form 2631, Performance Evaluation (Architect-Engineer), instead of SF 1421. (2) Prepare a separate...

  9. The Performance of Structure-Controller Coupled Systems Analysis Using Probabilistic Evaluation and Identification Model Approach

    Directory of Open Access Journals (Sweden)

    Mosbeh R. Kaloop

    2017-01-01

    Full Text Available This study evaluates the performance of passively controlled steel frame building under dynamic loads using time series analysis. A novel application is utilized for the time and frequency domains evaluation to analyze the behavior of controlling systems. In addition, the autoregressive moving average (ARMA neural networks are employed to identify the performance of the controller system. Three passive vibration control devices are utilized in this study, namely, tuned mass damper (TMD, tuned liquid damper (TLD, and tuned liquid column damper (TLCD. The results show that the TMD control system is a more reliable controller than TLD and TLCD systems in terms of vibration mitigation. The probabilistic evaluation and identification model showed that the probability analysis and ARMA neural network model are suitable to evaluate and predict the response of coupled building-controller systems.

  10. Computed radiography systems performance evaluation;Avaliacao de desempenho de sistemas de radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  11. Evaluating electronic performance support systems: A methodology focused on future use-in-practice

    NARCIS (Netherlands)

    Collis, Betty; Verwijs, C.A.

    1995-01-01

    Electronic performance support systems, as an emerging type of software environment, present many new challenges in relation to effective evaluation. In this paper, a global approach to a 'usage-orientated' evaluation methodology for software product is presented, followed by a specific example of

  12. Development and Performance Evaluation of Image-Based Robotic Waxing System for Detailing Automobiles.

    Science.gov (United States)

    Lin, Chi-Ying; Hsu, Bing-Cheng

    2018-05-14

    Waxing is an important aspect of automobile detailing, aimed at protecting the finish of the car and preventing rust. At present, this delicate work is conducted manually due to the need for iterative adjustments to achieve acceptable quality. This paper presents a robotic waxing system in which surface images are used to evaluate the quality of the finish. An RGB-D camera is used to build a point cloud that details the sheet metal components to enable path planning for a robot manipulator. The robot is equipped with a multi-axis force sensor to measure and control the forces involved in the application and buffing of wax. Images of sheet metal components that were waxed by experienced car detailers were analyzed using image processing algorithms. A Gaussian distribution function and its parameterized values were obtained from the images for use as a performance criterion in evaluating the quality of surfaces prepared by the robotic waxing system. Waxing force and dwell time were optimized using a mathematical model based on the image-based criterion used to measure waxing performance. Experimental results demonstrate the feasibility of the proposed robotic waxing system and image-based performance evaluation scheme.

  13. Standard guide for evaluating performance characteristics of phased-Array ultrasonic testing instruments and systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide describes procedures for evaluating some performance characteristics of phased-array ultrasonic examination instruments and systems. 1.2 Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this guide are expressed in terms that relate to their potential usefulness for ultrasonic examinations. Other electronic instrument characteristics in phased-array units are similar to non-phased-array units and may be measured as described in E 1065 or E 1324. 1.3 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be evaluated. 1.4 This guide establishes no performance limits for examination systems; if such acceptance criteria ar...

  14. Performance evaluation of a continuous flow inclined solar still desalination system

    International Nuclear Information System (INIS)

    El-Agouz, S.A.; El-Samadony, Y.A.F.; Kabeel, A.E.

    2015-01-01

    Highlights: • A mathematical model was presented to analyze the performance of inclined still. • The effect of air speed, water masses, film thickness and velocity was studied. • Productivity for the Model 3 was higher than conventional still by 57.2%. • The performance was strongly affected by water film thickness and velocity. • Model 3 gave the highest performance while Model 1 gave the lowest performance. - Abstract: In the present work, theoretical study of the performance evaluation of a continuous water flow inclined solar still desalination system is performed. Three models are studied for inclined solar still desalination system with and without water close loop. The effects of the water mass, water film thickness, water film velocity and air wind velocity on the performance of the three models are studied. The results show that the inclined solar still with a makeup water is superior in productivity (57.2% improvement) compared with a conventional basin-type solar still. Also, the application of inclined solar still with open water loop is recommended when combined with other still desalination system due to high water temperature output. The inclined solar still with a makeup (Model 3) gives the highest performance while Model 1 gives the lowest performance. Finally, the water film thickness, and velocity as well as wind velocity plays important roles in improving the still productivity and efficiency

  15. Performance evaluation and experiment system for waste heat recovery of diesel engine

    International Nuclear Information System (INIS)

    Wenzhi, Gao; Junmeng, Zhai; Guanghua, Li; Qiang, Bian; Liming, Feng

    2013-01-01

    In this paper, a waste heat recovery system is proposed where a high speed turbocharged diesel engine acts as the topper of a combined cycle with exhaust gases used for a bottoming Rankine cycle. The paper describes a mathematical model to evaluate the performance of Rankine cycle system with a reciprocating piston expander. The paper focuses on the performance evaluation and parameter selection of the heat exchanger and reciprocating piston expander that are suitable to waste heat recovery of ICE (internal combustion engine). The paper also describes the experimental setup and the preliminary results. The simulation results show that a proper intake pressure should be 4–5 MPa at its given mass flow rate of 0.015–0.021 kg/s depending on the waste heat recovery of a turbocharged diesel engine (80 kW/2590 rpm). The net power and net power rise rate at various ICE rotation speeds are calculated. The result shows that introducing heat recovery system can increase the engine power output by 12%, when diesel engine operates at 80 kW/2590 rpm. The preliminary experimental results indirectly prove the simulation model by two negative work loops in the P–V curve, under a low intake pressure and steam flow rate condition. - Highlights: • We investigate waste heat recovery through secondary fluid power cycle. • We establish a thermodynamic model of reciprocating steam engine. • We conduct the performance evaluation and experimental system development. • Primary parameters of the heat exchangers and expander are determined

  16. Influences of faculty evaluating system on educational performance of medical school faculty.

    Science.gov (United States)

    Kim, Hong Bin; Myung, Sun Jung; Yu, Hyeong Gon; Chang, Ji Young; Shin, Chan Soo

    2016-09-01

    The promotion of educators is challenged by the lack of accepted standards to evaluate the quality and impact of educational activities. Traditionally, promotion is related to research productivity. This study developed an evaluation tool for educational performance of medical school faculty using educator portfolios (EPs). Design principles and quantitative items for EPs were developed in a consensus workshop. These principles were tested in a simulation and revised based on feedback. The changes of total educational activities following introduction of the system were analyzed. A total of 71% faculty members answered the simulation of the system and the score distributed widely (mean±standard deviation, 65.43±68.64). The introduction of new system significantly increased the total educational activities, especially in assistant professors. The authors offer comprehensive and practical tool for enhancing educational participation of faculty members. Further research for development of qualitative evaluation systems is needed.

  17. The equity lens in the health care performance evaluation system.

    Science.gov (United States)

    Barsanti, Sara; Nuti, Sabina

    2014-01-01

    The main objective of this paper is to describe how indicators of the equity of access to health care according to socioeconomic conditions may be included in a performance evaluation system (PES) in the regional context level and in the planning and strategic control system of healthcare organisations. In particular, the paper investigates how the PES adopted, in the experience of the Tuscany region in Italy, indicators of vertical equity over time. Studies that testify inequality of access to health services often remain just a research output and are not used as targets and measurements in planning and control systems. After a brief introduction to the concept of horizontal and vertical equity in health care systems and equity measures in PES, the paper describes the 'equity process' by which selected health indicators declined by socioeconomic conditions were shared and used in the evaluation of health care institutions and in the CEOs' rewarding system, and subsequently analyses the initial results. Results on the maternal and child path and the chronicity care path not only show improvements in addressing health care inequalities, but also verify whether the health system responds appropriately to different population groups. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Cloud service performance evaluation: status, challenges, and opportunities – a survey from the system modeling perspective

    Directory of Open Access Journals (Sweden)

    Qiang Duan

    2017-05-01

    Full Text Available With rapid advancement of Cloud computing and networking technologies, a wide spectrum of Cloud services have been developed by various providers and utilized by numerous organizations as indispensable ingredients of their information systems. Cloud service performance has a significant impact on performance of the future information infrastructure. Thorough evaluation on Cloud service performance is crucial and beneficial to both service providers and consumers; thus forming an active research area. Some key technologies for Cloud computing, such as virtualization and the Service-Oriented Architecture (SOA, bring in special challenges to service performance evaluation. A tremendous amount of effort has been put by the research community to address these challenges and exciting progress has been made. Among the work on Cloud performance analysis, evaluation approaches developed with a system modeling perspective play an important role. However, related works have been reported in different sections of the literature; thus lacking a big picture that shows the latest status of this area. The objectives of this article is to present a survey that reflects the state of the art of Cloud service performance evaluation from the system modeling perspective. This articles also examines open issues and challenges to the surveyed evaluation approaches and identifies possible opportunities for future research in this important field.

  19. Assessment of three risk evaluation systems for patients aged ≥70 in East China: performance of SinoSCORE, EuroSCORE II and the STS risk evaluation system.

    Science.gov (United States)

    Shan, Lingtong; Ge, Wen; Pu, Yiwei; Cheng, Hong; Cang, Zhengqiang; Zhang, Xing; Li, Qifan; Xu, Anyang; Wang, Qi; Gu, Chang; Zhang, Yangyang

    2018-01-01

    To assess and compare the predictive ability of three risk evaluation systems (SinoSCORE, EuroSCORE II and the STS risk evaluation system) in patients aged ≥70, and who underwent coronary artery bypass grafting (CABG) in East China. Three risk evaluation systems were applied to 1,946 consecutive patients who underwent isolated CABG from January 2004 to September 2016 in two hospitals. Patients were divided into two subsets according to their age: elderly group (age ≥70) with a younger group (age evaluation system were 0.78(0.64)%, 1.43(1.14)% and 0.78(0.77)%, respectively. SinoSCORE achieved the best discrimination (the area under the receiver operating characteristic curve (AUC) = 0.829), followed by the STS risk evaluation system (AUC = 0.790) and EuroSCORE II (AUC = 0.769) in the entire cohort. In the elderly group, the observed mortality rate was 4.82% while it was 1.38% in the younger group. SinoSCORE (AUC = .829) also achieved the best discrimination in the elderly group, followed by the STS risk evaluation system (AUC = .730) and EuroSCORE II (AUC = 0.640) while all three risk evaluation systems all had good performances in the younger group. SinoSCORE, EuroSCORE II and the STS risk evaluation system all achieved positive calibrations in the entire cohort and subsets. The performance of the three risk evaluation systems was not ideal in the entire cohort. In the elderly group, SinoSCORE appeared to achieve better predictive efficiency than EuroSCORE II and the STS risk evaluation system.

  20. Performance Evaluation of Sectored MPAC for 5G UE Antenna Systems

    DEFF Research Database (Denmark)

    Hekkala, Aki; Kyösti, Pekka; Kyröläinen, Jukka

    2018-01-01

    Over-the-air (OTA) test system performance evaluations is a topic to agree in the industry to be able to guarantee the comparability of the test results from different laboratories. For 5G test purposes at mmWave there are no currently metrics to be used. This paper presents both the recently...

  1. Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

    Science.gov (United States)

    Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.

    2016-01-01

    Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

  2. Influences of faculty evaluating system on educational performance of medical school faculty

    Directory of Open Access Journals (Sweden)

    Hong Bin Kim

    2016-09-01

    Full Text Available Purpose: The promotion of educators is challenged by the lack of accepted standards to evaluate the quality and impact of educational activities. Traditionally, promotion is related to research productivity. This study developed an evaluation tool for educational performance of medical school faculty using educator portfolios (EPs. Methods: Design principles and quantitative items for EPs were developed in a consensus workshop. These principles were tested in a simulation and revised based on feedback. The changes of total educational activities following introduction of the system were analyzed. Results: A total of 71% faculty members answered the simulation of the system and the score distributed widely (mean±standard deviation, 65.43±68.64. The introduction of new system significantly increased the total educational activities, especially in assistant professors. Conclusion: The authors offer comprehensive and practical tool for enhancing educational participation of faculty members. Further research for development of qualitative evaluation systems is needed.

  3. Performance evaluation of nuclear grade filters for the Trupact-I pressure equalization system

    International Nuclear Information System (INIS)

    Sandoval, R.P.; Joseph, B.J.

    1987-01-01

    The performance of high-efficiency-particulate-air and ultra-low- penetration-air filters subjected to extreme environments of temperature, shock, pressure, and particulate loading was evaluated in a test program at the Sandia National Laboratories. The test program was initiated to evaluate the feasibility of using commercially available nuclear-grade filters in the filtered pressure equalization system of a contact-handled transuranic waste transport system, called TRUPACT-I. The filtered pressure equalization system of TRUPACT-I assures containment of the activity within the limits permitted by federal regulations and simultaneously equalizes the pressure between the cavity of the packaging and the environment, and minimizes the buildup of radiolytically generated gases. The filters were exposed to temperatures, pressures and stresses that exceed expected environments in normal and accident conditions of transport. The performance of the test filters was determined by measuring and quantifying filter efficiency and the Darcy constant. In addition, the integrity of the filter housing was evaluated using non-destructive helium leak testing. The details of the test program and results obtained from the tests are presented in this paper

  4. A new test procedure to evaluate the performance of substations for collective heating systems

    Science.gov (United States)

    Baetens, Robin; Verhaert, Ivan

    2017-11-01

    The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  5. A new test procedure to evaluate the performance of substations for collective heating systems

    Directory of Open Access Journals (Sweden)

    Baetens Robin

    2017-01-01

    Full Text Available The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  6. Performance Evaluation of a Biometric System Based on Acoustic Images

    Science.gov (United States)

    Izquierdo-Fuente, Alberto; del Val, Lara; Jiménez, María I.; Villacorta, Juan J.

    2011-01-01

    An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side). Two Uniform Linear Arrays (ULA) with 15 λ/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR)/False Non-Match Rate (FNMR) parameters and the Receiver Operating Characteristic (ROC) curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications. PMID:22163708

  7. Performance Evaluation of a Biometric System Based on Acoustic Images

    Directory of Open Access Journals (Sweden)

    Juan J. Villacorta

    2011-10-01

    Full Text Available An acoustic electronic scanning array for acquiring images from a person using a biometric application is developed. Based on pulse-echo techniques, multifrequency acoustic images are obtained for a set of positions of a person (front, front with arms outstretched, back and side. Two Uniform Linear Arrays (ULA with 15 l/2-equispaced sensors have been employed, using different spatial apertures in order to reduce sidelobe levels. Working frequencies have been designed on the basis of the main lobe width, the grating lobe levels and the frequency responses of people and sensors. For a case-study with 10 people, the acoustic profiles, formed by all images acquired, are evaluated and compared in a mean square error sense. Finally, system performance, using False Match Rate (FMR/False Non-Match Rate (FNMR parameters and the Receiver Operating Characteristic (ROC curve, is evaluated. On the basis of the obtained results, this system could be used for biometric applications.

  8. Performance Evaluation of Speech Recognition Systems as a Next-Generation Pilot-Vehicle Interface Technology

    Science.gov (United States)

    Arthur, Jarvis J., III; Shelton, Kevin J.; Prinzel, Lawrence J., III; Bailey, Randall E.

    2016-01-01

    During the flight trials known as Gulfstream-V Synthetic Vision Systems Integrated Technology Evaluation (GV-SITE), a Speech Recognition System (SRS) was used by the evaluation pilots. The SRS system was intended to be an intuitive interface for display control (rather than knobs, buttons, etc.). This paper describes the performance of the current "state of the art" Speech Recognition System (SRS). The commercially available technology was evaluated as an application for possible inclusion in commercial aircraft flight decks as a crew-to-vehicle interface. Specifically, the technology is to be used as an interface from aircrew to the onboard displays, controls, and flight management tasks. A flight test of a SRS as well as a laboratory test was conducted.

  9. High-Performance Operating Systems

    DEFF Research Database (Denmark)

    Sharp, Robin

    1999-01-01

    Notes prepared for the DTU course 49421 "High Performance Operating Systems". The notes deal with quantitative and qualitative techniques for use in the design and evaluation of operating systems in computer systems for which performance is an important parameter, such as real-time applications......, communication systems and multimedia systems....

  10. Integrating Soft Set Theory and Fuzzy Linguistic Model to Evaluate the Performance of Training Simulation Systems.

    Science.gov (United States)

    Chang, Kuei-Hu; Chang, Yung-Chia; Chain, Kai; Chung, Hsiang-Yu

    2016-01-01

    The advancement of high technologies and the arrival of the information age have caused changes to the modern warfare. The military forces of many countries have replaced partially real training drills with training simulation systems to achieve combat readiness. However, considerable types of training simulation systems are used in military settings. In addition, differences in system set up time, functions, the environment, and the competency of system operators, as well as incomplete information have made it difficult to evaluate the performance of training simulation systems. To address the aforementioned problems, this study integrated analytic hierarchy process, soft set theory, and the fuzzy linguistic representation model to evaluate the performance of various training simulation systems. Furthermore, importance-performance analysis was adopted to examine the influence of saving costs and training safety of training simulation systems. The findings of this study are expected to facilitate applying military training simulation systems, avoiding wasting of resources (e.g., low utility and idle time), and providing data for subsequent applications and analysis. To verify the method proposed in this study, the numerical examples of the performance evaluation of training simulation systems were adopted and compared with the numerical results of an AHP and a novel AHP-based ranking technique. The results verified that not only could expert-provided questionnaire information be fully considered to lower the repetition rate of performance ranking, but a two-dimensional graph could also be used to help administrators allocate limited resources, thereby enhancing the investment benefits and training effectiveness of a training simulation system.

  11. Breaking the Bathsheba Syndrome: Building a Performance Evaluation System that Promotes Mission Command

    Science.gov (United States)

    2015-10-01

    managerial philoso- phy that still regards Army leaders as interchangeable parts. The result of this clash of ethos is a cognitive dissonance within the...bias.30 A well-doc- umented cognitive bias, the halo effect, occurs when a high-performer in one well-observed domain is as- sumed to perform equally...briefings before superiors, benefit from this cognitive bias. Recent scholarship on single-source performance evaluation systems, such as the infamous

  12. Evaluating Nonclinical Performance of the Academic Pathologist

    Directory of Open Access Journals (Sweden)

    Austin Blackburn Wiles MD

    2018-02-01

    Full Text Available Academic pathologists perform clinical duties, as well as valuable nonclinical activities. Nonclinical activities may consist of research, teaching, and administrative management among many other important tasks. While clinical duties have many clear metrics to measure productivity, like the relative value units of Medicare reimbursement, nonclinical performance is often difficult to measure. Despite the difficulty of evaluating nonclinical activities, nonclinical productivity is used to determine promotion, funding, and inform professional evaluations of performance. In order to better evaluate the important nonclinical performance of academic pathologists, we present an evaluation system for leadership use. This system uses a Microsoft Excel workbook to provide academic pathologist respondents and reviewing leadership a transparent, easy-to-complete system that is both flexible and scalable. This system provides real-time feedback to academic pathologist respondents and a clear executive summary that allows for focused guidance of the respondent. This system may be adapted to fit practices of varying size, measure performance differently based on years of experience, and can work with many different institutional values.

  13. Performability Modelling Tools, Evaluation Techniques and Applications

    NARCIS (Netherlands)

    Haverkort, Boudewijn R.H.M.

    1990-01-01

    This thesis deals with three aspects of quantitative evaluation of fault-tolerant and distributed computer and communication systems: performability evaluation techniques, performability modelling tools, and performability modelling applications. Performability modelling is a relatively new

  14. NETRA: A parallel architecture for integrated vision systems 2: Algorithms and performance evaluation

    Science.gov (United States)

    Choudhary, Alok N.; Patel, Janak H.; Ahuja, Narendra

    1989-01-01

    In part 1 architecture of NETRA is presented. A performance evaluation of NETRA using several common vision algorithms is also presented. Performance of algorithms when they are mapped on one cluster is described. It is shown that SIMD, MIMD, and systolic algorithms can be easily mapped onto processor clusters, and almost linear speedups are possible. For some algorithms, analytical performance results are compared with implementation performance results. It is observed that the analysis is very accurate. Performance analysis of parallel algorithms when mapped across clusters is presented. Mappings across clusters illustrate the importance and use of shared as well as distributed memory in achieving high performance. The parameters for evaluation are derived from the characteristics of the parallel algorithms, and these parameters are used to evaluate the alternative communication strategies in NETRA. Furthermore, the effect of communication interference from other processors in the system on the execution of an algorithm is studied. Using the analysis, performance of many algorithms with different characteristics is presented. It is observed that if communication speeds are matched with the computation speeds, good speedups are possible when algorithms are mapped across clusters.

  15. Evaluation of Management Control Systems in Higher Education Institution with the Performance Management and Control

    Directory of Open Access Journals (Sweden)

    Ilse Maria Beuren

    2014-10-01

    Full Text Available This study aims to investigate the structure and operation of management control systems for performance evaluation in a private higher education institution (HEI. To capture the structure and operation of Management Control Systems (MCS of the HEI, the survey instrument proposed by Ferreira and Otley was used (2006, called Performance Management and Control (PMC. Thus, an adapted PMC structure questionnaire was sent to 55 managers responsible for strategic actions and plans established in the business of the HEI, having 48 answered questionnaires. Also, four out of the five directors of the business school of the HEI were interviewed, besides the documentary research, for the triangulation of data and to validate the results. In data analysis, the techniques of descriptive statistics and information entropy were used. The results show that the overall level of performance evaluation for MCS reached a mean of 3.62 on the scale, less than partial agreement on the items presented. Some weaknesses were pointed out in the system used, and it was also denoted the need for better alignment among strategy, performance and control. It is concluded that the adapted PMC structure questionnaire managed to capture the structure and operation of MCS for performance evaluation in the HEI.

  16. Performance evaluation of near-real-time accounting systems

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Examples are given illustrating the application of near-real-time accounting concepts and principles to actual nuclear facilities. Experience with prototypical systems at the AGNS reprocessing plant and the Los Alamos plutonium facility is described using examples of actual data to illustrate the performance and effectiveness of near-real-time systems. The purpose of the session is to enable participants to: (1) identify the major components of near-real-time accounting systems; (2) describe qualitatively the advantages, limitations, and performance of such systems in real nuclear facilities; (3) identify process and facility design characteristics that affect the performance of near-real-time systems; and (4) describe qualitatively the steps necessary to implement a near-real-time accounting and control system in a nuclear facility

  17. Solar-energy system performance evaluation. San Anselmo School, San Jose, California, July 1980-March 1981

    Energy Technology Data Exchange (ETDEWEB)

    Pakkala, P.A.

    1981-01-01

    The San Anselmo School is a one-story, brick elementary school building located in San Jose, California. The active solar energy system is designed to supply 70% of the heating load and 72% of the cooling load. It is equipped with 3.740 square feet of evacuated tube collectors, 2175-gallon tank for storage, four auxiliary gas-fired absorption chiller/heaters, and a solar-supplied absorption chiller. The measured heating and cooling solar fractions were 9% and 19%, respectively, for an overall solar fraction of 16%, the lowered performance being attributed to severe system control problems. Performance data include the solar savings ratio, conventional fuel savings, system performance factor, and solar system coefficient of performance. Performance data are presented for the overall system and for each subsystem. System operation and solar energy utilization data are included. Also included are a description of the system, performance evaluation techniques, sensor technology, and typical performance data for a month. Weather data are also tabulated. (LEW)

  18. Comparison Evaluations of VRF and RTU Systems Performance on Flexible Research Platform

    Directory of Open Access Journals (Sweden)

    Je-hyeon Lee

    2018-01-01

    Full Text Available The energy performance of a variable refrigerant flow (VRF system was evaluated using an occupancy-emulated research building in the southeastern region of the United States. Full- and part-load performance of the VRF system in heating and cooling seasons was compared with a conventional rooftop unit (RTU variable-air-volume system with electric resistance heating. During both the heating and cooling seasons, full- and part-load conditions (i.e., 100%, 75%, and 50% thermal loads were maintained alternately for 2 to 3 days each, and the energy use, thermal conditions, and coefficient of performance (COP for the RTU and VRF system were measured. During the cooling season, the VRF system had an average COP of 4.2, 3.9, and 3.7 compared with 3.1, 3.0, and 2.5 for the RTU system under 100%, 75%, and 50% load conditions and resulted in estimated energy savings of 30%, 37%, and 47%, respectively. During the heating season, the VRF system had an average COP ranging from 1.2 to 2.0, substantially higher than the COPs of the RTU system, and resulted in estimated energy savings of 51%, 47%, and 27% under the three load conditions, respectively.

  19. Study on safety performance evaluation system of nuclear engineering construction units based on AHP

    International Nuclear Information System (INIS)

    Xu Yulin; Sun Jian; Shi Xiaofan

    2012-01-01

    As a very effectual management mean, the performance management has extensively used by many companies of China for staff assessment. The author explored the establishment of the 'Safety Performance Evaluation System' by finding out the similarities in operation between a company and a team of nuclear power projects. Then the author analyzed the principles of the performance management and good practices and summarized safety management experiences. The weight of the system index by using AHP method was calculated in this article. (authors)

  20. Performance evaluation of an integrated automotive air conditioning and heat pump system

    International Nuclear Information System (INIS)

    Hosoz, M.; Direk, M.

    2006-01-01

    This study deals with the performance characteristics of an R134a automotive air conditioning system capable of operating as an air-to-air heat pump using ambient air as a heat source. For this aim, an experimental analysis has been performed on a plant made up of original components from an automobile air conditioning system and some extra equipment employed to operate the system in the reverse direction. The system has been tested in the air conditioning and heat pump modes by varying the compressor speed and air temperatures at the inlets of the indoor and outdoor coils. Evaluation of the data gathered in steady state test runs has shown the effects of the operating conditions on the capacity, coefficient of performance, compressor discharge temperature and the rate of exergy destroyed by each component of the system for both operation modes. It has been observed that the heat pump operation provides adequate heating only in mild weather conditions, and the heating capacity drops sharply with decreasing outdoor temperature. However, compared with the air conditioning operation, the heat pump operation usually yields a higher coefficient of performance and a lower rate of exergy destruction per unit capacity. It is also possible to improve the heating mode performance of the system by redesigning the indoor coil, using another refrigerant with a higher heat rejection rate in the condenser and employing a better heat source such as the engine coolant or exhaust gases

  1. Evaluation of heat exchange performance for the auxiliary component cooling water system cooling tower in HTTR

    International Nuclear Information System (INIS)

    Tochio, Daisuke; Kameyama, Yasuhiko; Shimizu, Atsushi; Inoi, Hiroyuki; Yamazaki, Kazunori; Shimizu, Yasunori; Aragaki, Etsushi; Ota, Yukimaru; Fujimoto, Nozomu

    2006-09-01

    The auxiliary component cooling water system (ACCWS) is one of the cooling system in High Temperature Engineering Test Reactor (HTTR). The ACCWS has main two features, many facilities cooling, and heat sink of the vessel cooling system which is one of the engineering safety features. Therefore, the ACCWS is required to satisfy the design criteria of heat removal performance. In this report, heat exchange performance data of the rise-to-power-up test and the in-service operation for the ACCWS cooling tower was evaluated. Moreover, the evaluated values were compared with the design values, and it is confirmed that ACCWS cooling tower has the required heat exchange performance in the design. (author)

  2. Performance evaluation of a crystal-enhanced collimation system for the LHC

    CERN Document Server

    Previtali, Valentina; Assmann, Ralph

    2010-01-01

    The Large Hadron Collider (LHC) has been constructed at CERN (Conseil Européen pour la Recherche Nucléaire, Geneva, Switzerland), and recently started up. The LHC beams, currently accelerated to 3.5 TeV, are meant to reach the nominal energy of 7 TeV, and a total stored energy, in nominal conditions, of 360 MJ per beam. The contrast between the huge stored power and the delicate cryogenic environment calls for a sophisticated collimation system. For overcoming the limitations of the actual collimation system, different upgrade solutions have been considered; this Ph.D. work gives a first performance evaluation of a crystal-enhanced collimation system by analytical, experimental and simulation investigations. In this work, two crystal collimation experiments are described: the T980 (Teva- tron, Chicago, U.S.) and the UA9 (SPS, CERN, Geneva, Switzerland). The data are analyzed and actual crystal performances are measured. These experimental results and their cross-check with dedicated simulations constitute...

  3. Performance Evaluation of Air-Based Heat Rejection Systems

    Directory of Open Access Journals (Sweden)

    Hannes Fugmann

    2015-01-01

    Full Text Available On the basis of the Number of Transfer Units (NTU method a functional relation between electric power for fans/pumps and effectiveness in dry coolers and wet cooling towers is developed. Based on this relation, a graphical presentation method of monitoring and simulation data of heat rejection units is introduced. The functional relation allows evaluating the thermodynamic performance of differently sized heat rejection units and comparing performance among them. The method is used to evaluate monitoring data of dry coolers of different solar cooling field projects. The novelty of this approach is that performance rating is not limited by a design point or standardized operating conditions of the heat exchanger, but is realizable under flexible conditions.

  4. Evaluating Library Staff: A Performance Appraisal System.

    Science.gov (United States)

    Belcastro, Patricia

    This manual provides librarians and library managers with a performance appraisal system that measures staff fairly and objectively and links performance to the goals of the library. The following topics are addressed: (1) identifying expectations for quality service or standards of performance; (2) the importance of a library's code of service,…

  5. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  6. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  7. Integrated model of assisted parking system and performance evaluation with entropy weight extended analytic hierarchy process and two-tuple linguistic information

    Directory of Open Access Journals (Sweden)

    Yiding Hua

    2016-06-01

    Full Text Available Evaluating comprehensive performance of assisted parking system has been a very important issue for car companies for years, because the overall performance of assisted parking system directly influences car intellectualization and customers’ degree of satisfaction. Therefore, this article proposes two-tuple linguistic analytic hierarchy process to evaluate assisted parking system so as to avoid information loss during the processes of evaluation integration. The performance evaluation attributes for assisted parking system are established initially. Subsequently, the information entropy theory is proposed to improve the evaluation attribute weight determined by analytic hierarchy process for the influencing factors of the randomness in parking test process. Furthermore, the evaluation attribute measure values of comprehensive performance are calculated and the assisted parking system evaluation results are obtained with ordered weighted averaging operator. Finally, numerical examples of vehicle types equipped with eight different assisted parking systems and computational results are presented.

  8. 48 CFR 1252.216-72 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Performance evaluation....216-72 Performance evaluation plan. As prescribed in (TAR) 48 CFR 1216.406(b), insert the following clause: Performance Evaluation Plan (OCT 1994) (a) A Performance Evaluation Plan shall be unilaterally...

  9. Experimental Simulation-Based Performance Evaluation of an SMS-Based Emergency Geolocation Notification System

    Directory of Open Access Journals (Sweden)

    Isibor Osebor

    2017-01-01

    Full Text Available In an emergency, a prompt response can save the lives of victims. This statement generates an imperative issue in emergency medical services (EMS. Designing a system that brings simplicity in locating emergency scenes is a step towards improving response time. This paper therefore implemented and evaluated the performance of an SMS-based emergency geolocation notification system with emphasis on its SMS delivery time and the system’s geolocation and dispatch time. Using the RAS metrics recommended by IEEE for evaluation, the designed system was found to be efficient and effective as its reliability stood within 62.7% to 70.0% while its availability stood at 99% with a downtime of 3.65 days/year.

  10. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    Energy Technology Data Exchange (ETDEWEB)

    Du, Louise Y [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada); Umoh, Joseph [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Nikolov, Hristo N [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Pollmann, Steven I [Imaging Research Laboratories, Robarts Research Institute, London, ON (Canada); Lee, Ting-Yim [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada); Holdsworth, David W [Department of Medical Biophysics, University of Western Ontario, London, ON (Canada)

    2007-12-07

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 {mu}m, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm{sup -1} and noise of {+-}35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.

  11. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems

    International Nuclear Information System (INIS)

    Du, Louise Y; Umoh, Joseph; Nikolov, Hristo N; Pollmann, Steven I; Lee, Ting-Yim; Holdsworth, David W

    2007-01-01

    Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 μm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm -1 and noise of ±35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy

  12. Performance evaluation of a flow-down collecting solar system; Ryuka shunetsushiki solar system no seino hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Kanayama, K; Li, X; Baba, H; Endo, N [Kitami Institute of Technology, (Japan)

    1997-11-25

    The paper evaluated performance of a flow-down collecting solar system. The solar heat pump PV system is composed of a solar system, heat pump and PV, of which the heat collecting portion is a water-use horizontal evacuated double glass tube solar collector. As a result of the performance measurement, the necessity of fundamental improvement arose. Under an idea of disproving common sense of the original forced circulation solar system, a system was designed in which heat is collected by making the heat media reversely circulate and flow down in accordance with gravity. When the flow rate was 2m{sup 3}/h, the collecting rate reached a maximum, approximately 54% (36.9% before improvement). When the flow rate was 1.3-1.5m{sup 3}/h, the system can realize the maximum merit, and the collecting efficiency became approximately 50%. Helped by reduction in consumed power, the average system performance coefficient reached more than 85% (28.9% before improvement). The obtainable energy rate rapidly increased to 2.9 times more than before improvement. Further, the consumed power of pump was decreased 65% from before improvement when the flow rate was 2.4m{sup 3}/h. 2 refs., 5 figs.

  13. PERFORMANCE EVALUATION: LITERATURE REVIEW AND TIME EVOLUTION.

    Directory of Open Access Journals (Sweden)

    Pintea Mirela-Oana

    2012-07-01

    Full Text Available Performance evaluation of an economic entity requires approaching several criteria, such as industry and economic entity type, managerial and entrepreneurial strategy, competitive environment, human and material resources available, using a system of appropriate performance indicators for this purpose.The exigencies of communication occurred on the growing number of phenomena that marked the global economy in recent decades (internationalization and relocation of business crises and turmoil in financial markets, demand performance measurement to be made in a comprehensive way by financial and non-financial criteria. Indicators are measures of performance used by management to measure, report and improve performance of the economic entity. The relationship between indicators and management is ensured by the existence of performance measurement systems. Studies to date indicate that economic entities using balanced performance measurement systems as a key management tool registered superior performance compared to entities not using such systems. This study attempts to address the issue of performance evaluation by presenting opinions of different authors concerning the process of performance measurement and to present, after revising the literature, the evolution of the performance evaluation systems. We tried to do this literature review because sustainable development and, therefore, globalization require new standards of performance that exceeds the economic field, both for domestic companies as well as international ones. So, these standards should be integrated into corporate strategy development to ensure sustainability of activities undertaken by harmonizing the economic, social and environmental objectives. To assess the performance of economic entities it is required that performance evaluation to be done with a balanced multidimensional system, including both financial ratios and non-financial indicators in order to reduce the limits of

  14. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain repository

    International Nuclear Information System (INIS)

    Atkins, J.E.; Lee, J.H.; Lingineni, S.; Mishra, S.; McNeish, J.A.; Sassani, D.C.; Sevougian, S.D.

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation's commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives of the US NRC and the US EPA. The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). Total system performance assessments require the explicit quantification of the relevant processes and process interactions. In addition assessments are useful to help define the most significant processes, the information gaps and uncertainties and therefore the additional information required for more robust and defensible assessment of the overall performance. The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993

  15. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain repository

    Energy Technology Data Exchange (ETDEWEB)

    Atkins, J.E.; Lee, J.H.; Lingineni, S.; Mishra, S; McNeish, J.A.; Sassani, D.C.; Sevougian, S.D.

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation`s commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives of the US NRC and the US EPA. The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). Total system performance assessments require the explicit quantification of the relevant processes and process interactions. In addition assessments are useful to help define the most significant processes, the information gaps and uncertainties and therefore the additional information required for more robust and defensible assessment of the overall performance. The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993.

  16. Test plan for evaluating the performance of the in-tank fluidic sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by a privatization contractor from double-shell feed tanks, 241-AP-102 and 241-AP-104, Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a conceptual sampling system that would be deployed in a feed tank riser, This sampling system will provide large volume, representative samples without the environmental, radiation exposure, and sample volume impacts of the current base-line ''grab'' sampling method. This test plan identifies ''proof-of-principle'' cold tests for the conceptual sampling system using simulant materials. The need for additional testing was identified as a result of completing tests described in the revision test plan document, Revision 1 outlines tests that will evaluate the performance and ability to provide samples that are representative of a tanks' content within a 95 percent confidence interval, to recovery from plugging, to sample supernatant wastes with over 25 wt% solids content, and to evaluate the impact of sampling at different heights within the feed tank. The test plan also identifies operating parameters that will optimize the performance of the sampling system

  17. Licensee Performance Evaluation: Phase II

    International Nuclear Information System (INIS)

    Chakoff, H.E.; Speaker, D.M.; Thompson, S.R.; Cohen, S.C.

    1979-08-01

    This report details work performed during the second phase of a two-phase contract to develop methodology for Licensee Performance Evaluation. The Phase I report, NUREG/CR-0110 details initial efforts on the contract. The model developed in Phase I was used to evaluate nine additional facilities for this report. Performance indicators from noncompliance data were also evaluated. Methodology was developed employing the noncompliance indicators and used for 12 case studies. It was found that licensee event report indicators could be more easily identified and utilized than noncompliance indicators based on presently available data systems. However, noncompliance data, appropriately related to cause, could provide real insight into why performance was what it was

  18. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  19. Evaluation of the Space and Naval Warfare Systems Command (SPAWAR) Cost and Performance Measurement

    OpenAIRE

    Flavell, Drew G.; Dorwin, Timothy E.

    1999-01-01

    Approved for public release; distribution is unlimited. This thesis examines the Cost and Performance Measurements within four Program Directorates at the Space and Naval Warfare Systems Command (SPAWAR). SPAWAR is the Navy's full-spectrum research, development, test and evaluation, engineering and fleet support center for Command, Control and Communications Systems, Ocean Surveillance Systems and the integration of those systems that overarch multiplatforms. In the era of lean military bu...

  20. Performance Evaluation Model for Application Layer Firewalls.

    Science.gov (United States)

    Xuan, Shichang; Yang, Wu; Dong, Hui; Zhang, Jiangchuan

    2016-01-01

    Application layer firewalls protect the trusted area network against information security risks. However, firewall performance may affect user experience. Therefore, performance analysis plays a significant role in the evaluation of application layer firewalls. This paper presents an analytic model of the application layer firewall, based on a system analysis to evaluate the capability of the firewall. In order to enable users to improve the performance of the application layer firewall with limited resources, resource allocation was evaluated to obtain the optimal resource allocation scheme in terms of throughput, delay, and packet loss rate. The proposed model employs the Erlangian queuing model to analyze the performance parameters of the system with regard to the three layers (network, transport, and application layers). Then, the analysis results of all the layers are combined to obtain the overall system performance indicators. A discrete event simulation method was used to evaluate the proposed model. Finally, limited service desk resources were allocated to obtain the values of the performance indicators under different resource allocation scenarios in order to determine the optimal allocation scheme. Under limited resource allocation, this scheme enables users to maximize the performance of the application layer firewall.

  1. Performance Evaluation Model for Application Layer Firewalls.

    Directory of Open Access Journals (Sweden)

    Shichang Xuan

    Full Text Available Application layer firewalls protect the trusted area network against information security risks. However, firewall performance may affect user experience. Therefore, performance analysis plays a significant role in the evaluation of application layer firewalls. This paper presents an analytic model of the application layer firewall, based on a system analysis to evaluate the capability of the firewall. In order to enable users to improve the performance of the application layer firewall with limited resources, resource allocation was evaluated to obtain the optimal resource allocation scheme in terms of throughput, delay, and packet loss rate. The proposed model employs the Erlangian queuing model to analyze the performance parameters of the system with regard to the three layers (network, transport, and application layers. Then, the analysis results of all the layers are combined to obtain the overall system performance indicators. A discrete event simulation method was used to evaluate the proposed model. Finally, limited service desk resources were allocated to obtain the values of the performance indicators under different resource allocation scenarios in order to determine the optimal allocation scheme. Under limited resource allocation, this scheme enables users to maximize the performance of the application layer firewall.

  2. Solar energy system performance evaluation: Scattergood School Recreation Center, West Branch, Iowa, September 1977--May 1978

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-01

    An operational summary is provided of the solar energy system performance at Scattergood School, West Branch, Iowa. This analysis is made by evaluation of measured system performance and by comparison of measured climatic data with long term average climatic conditions. Performance of major subsystems is also presented to illustrate their operation. The solar energy system, utilizing 2496 square feet of flat plate, air collectors, supplies a portion of the space heating and domestic hot water requirements for the 6900 square foot gymnasium and 1966 square feet of locker rooms at the Scattergood School, West Branch, Iowa. The solar energy system was installed during building construction. A 6000 bushel grain dryer, installed later, may also use the solar system during its operation. Included are: a brief system description, review of actual system performance during the report period, analysis of performance based on evaluation of climatic, load and operational conditions, and an overall discussion of results. The Scattergood solar energy system availability was 65 percent for the ECSS subsystem, 95 percent for the space heating subsystem and 55 percent for the hot water heating subsystem. The ECSS availability was affected by a malfunction of the total solar system during April 1--8 and April 14 through May 11. The hot water availability was greatly affected by the failure of the subsystem and resultant repair interval. The space heating subsystem operated throughout the entire reporting period except when the solar system was down in April and May.

  3. 48 CFR 3052.216-72 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Performance evaluation... CONTRACT CLAUSES Text of Provisions and Clauses 3052.216-72 Performance evaluation plan. As prescribed in... Evaluation Plan (DEC 2003) (a) A Performance Evaluation Plan shall be unilaterally established by the...

  4. The Decision Making Trial and Evaluation Laboratory (Dematel) and Analytic Network Process (ANP) for Safety Management System Evaluation Performance

    Science.gov (United States)

    Rolita, Lisa; Surarso, Bayu; Gernowo, Rahmat

    2018-02-01

    In order to improve airport safety management system (SMS) performance, an evaluation system is required to improve on current shortcomings and maximize safety. This study suggests the integration of the DEMATEL and ANP methods in decision making processes by analyzing causal relations between the relevant criteria and taking effective analysis-based decision. The DEMATEL method builds on the ANP method in identifying the interdependencies between criteria. The input data consists of questionnaire data obtained online and then stored in an online database. Furthermore, the questionnaire data is processed using DEMATEL and ANP methods to obtain the results of determining the relationship between criteria and criteria that need to be evaluated. The study cases on this evaluation system were Adi Sutjipto International Airport, Yogyakarta (JOG); Ahmad Yani International Airport, Semarang (SRG); and Adi Sumarmo International Airport, Surakarta (SOC). The integration grades SMS performance criterion weights in a descending order as follow: safety and destination policy, safety risk management, healthcare, and safety awareness. Sturges' formula classified the results into nine grades. JOG and SMG airports were in grade 8, while SOG airport was in grade 7.

  5. Evaluation of Heating, Ventilation, and Air conditioning (HVAC System Performance in an Administrative Building in Tehran (Iran

    Directory of Open Access Journals (Sweden)

    H. Mari Oriyad

    2014-09-01

    Full Text Available Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .Material and Method: A questionnaire, developed in their research was used to assess the building occupants’ perception about the performance of HVAC system. To evaluate the performance of HVAC systems, air velocities were measured in the diffusers using a thermal anemometer. Moreover, CO2 concentration, air temperature and relative humidity were measured in the whole floors of the building. Air distribution inside the building was evaluated using smoke test. .Results: Most of the studied people complained about the direction of airflow, thermal conditions and cigarette odor. The highest level of carbon dioxide was measured at 930 ppm inside the restaurant. The maximum and minimum air temperatures and relative humidity were measured 28.3-13.8° C and 28.4-23% respectively. Smoke test showed that the air distribution/direction wasn’t suitable in one third of air diffusers. .Conclusion: Improper air distribution / direction was the main problem with the studied HVAC system which could be corrected by adjusting and balancing of the system.

  6. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.

    Science.gov (United States)

    Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi

    2013-07-01

    Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and

  7. Performance evaluation of an off-grid photovoltaic system in Saudi Arabia

    International Nuclear Information System (INIS)

    Rehman, Shafiqur; El-Amin, Ibrahim

    2012-01-01

    The paper presents the performance evaluation analysis of a 5.28 kW installed capacity isolated grid photovoltaic power plant installed at King Fahd University of Petroleum and Minerals, Dhahran Saudi Arabia in June 2010. The plant was equipped with temperature, solar radiation intensity, and PV (Photovoltaic) panel power output recording sensors for performance evaluation of the plant. The analysis presented the effect of PV surface temperature and dust collected on the panels on the power output of individual arrays and total power from complete plant. Furthermore, the PV panel performance was studied by DC (Direct current) performance ratio variation with PV panel backside surface temperature. Hourly mean energy yield was found to be decreasing with increasing PV panel surface temperature during the months of July and August 2010. The daily energy yield showed a decreasing trend with days of the month which could be accounted for dust accumulation on the PV panel surface. The DC performance ratio also showed a decreasing trend with increasing PV panel surface temperature. -- Highlights: ► The study presents the effect of local weather conditions on the performance of a 5.28 kW isolated grid photovoltaic system. ► Local weather conditions effect was studied based on energy yield on diurnal and daily basis DC performance ratio. ► Hourly mean energy yield was found to be decreasing with increasing PV panel surface temperature. ► Daily energy yield decreased with days which could be accounted for dust accumulation on the PV panel surface. ► The DC performance ratio also showed a decreasing trend with increasing PV panel surface temperature.

  8. Performance evaluation of a hybrid-passive landfill leachate treatment system using multivariate statistical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Jack, E-mail: jack.wallace@ce.queensu.ca [Department of Civil Engineering, Queen’s University, Ellis Hall, 58 University Avenue, Kingston, Ontario K7L 3N6 (Canada); Champagne, Pascale, E-mail: champagne@civil.queensu.ca [Department of Civil Engineering, Queen’s University, Ellis Hall, 58 University Avenue, Kingston, Ontario K7L 3N6 (Canada); Monnier, Anne-Charlotte, E-mail: anne-charlotte.monnier@insa-lyon.fr [National Institute for Applied Sciences – Lyon, 20 Avenue Albert Einstein, 69621 Villeurbanne Cedex (France)

    2015-01-15

    Highlights: • Performance of a hybrid passive landfill leachate treatment system was evaluated. • 33 Water chemistry parameters were sampled for 21 months and statistically analyzed. • Parameters were strongly linked and explained most (>40%) of the variation in data. • Alkalinity, ammonia, COD, heavy metals, and iron were criteria for performance. • Eight other parameters were key in modeling system dynamics and criteria. - Abstract: A pilot-scale hybrid-passive treatment system operated at the Merrick Landfill in North Bay, Ontario, Canada, treats municipal landfill leachate and provides for subsequent natural attenuation. Collected leachate is directed to a hybrid-passive treatment system, followed by controlled release to a natural attenuation zone before entering the nearby Little Sturgeon River. The study presents a comprehensive evaluation of the performance of the system using multivariate statistical techniques to determine the interactions between parameters, major pollutants in the leachate, and the biological and chemical processes occurring in the system. Five parameters (ammonia, alkalinity, chemical oxygen demand (COD), “heavy” metals of interest, with atomic weights above calcium, and iron) were set as criteria for the evaluation of system performance based on their toxicity to aquatic ecosystems and importance in treatment with respect to discharge regulations. System data for a full range of water quality parameters over a 21-month period were analyzed using principal components analysis (PCA), as well as principal components (PC) and partial least squares (PLS) regressions. PCA indicated a high degree of association for most parameters with the first PC, which explained a high percentage (>40%) of the variation in the data, suggesting strong statistical relationships among most of the parameters in the system. Regression analyses identified 8 parameters (set as independent variables) that were most frequently retained for modeling

  9. The Dimensions of health system performance evaluation with emphasis on the coverage of the vulnerable groups in Iran

    Directory of Open Access Journals (Sweden)

    Shahri S ,

    2016-05-01

    Full Text Available Evaluation is an integral part of any executive job and activity using of information measurable improvement is followed in administrative activities as a main aim . This study was conducted with aim of determine factors evaluating the performance of health systems based on structural equation modeling. In this descriptive analytical and practical. This study was conducted during 2015. 419 experts participated in this study. Data collection was conducted through researcher made questionnaire. Validity of the questionnaire in the way of their content validity and reliability by using Cronbach's alpha coefficient (0.94 was confirmed. Data were analyzed using the software SPSS 22 and LISREL 8.8. Findings revealed that variable healthcare service delivery with impact factor 0.79 is the most important factor affecting the assessment of health system performance and variable equitable access to health services was in second place with impact factor of 0.72 after variable of health care delivery. Variables stewardship, financial resources, protection against financial risks and resource generation respectively with impact factor of 0.69, 0.58, 0.58 and 0.54 in evaluating the performance of the health system was in third place to sixth. Considering the dimensions of health system performance can be pay evaluating the performance tailored to conditions in the country in order to the objectives of the health system

  10. 48 CFR 2936.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Evaluation of contractor... Construction 2936.201 Evaluation of contractor performance. The HCA must establish procedures to evaluate construction contractor performance and prepare performance reports as required by FAR 36.201. ...

  11. Solar energy system performance evaluation: Seasonal report for Contemporary-Manchester, Manchester, New Hampshire

    Science.gov (United States)

    1980-01-01

    The operational and thermal performance of the solar energy system, Contemporary-Manchester, is described. The system was designed by Contemporary Systems Incorporated to provide space heating and domestic hot water preheating for a three story dwelling located on the New Hampshire Vocational Technical College campus, Manchester, New Hampshire. The net fossil energy savings for the period from March, 1979 to February, 1980 was 14.52 million Btu. However, the performance of the system must be degraded due to the fact that the building was unoccupied throughout the data assessment and analysis period. The unoccupied status prevented the normal adjustment of heating and ventilating controls for maintenance of comfort levels within the building. This lack of occupancy also prevented the typical family hot water usage, which would have allowed for more realistic evaluation of the hot water subsystem.

  12. Thermodynamic performance evaluation of combustion gas turbine cogeneration system with reheat

    International Nuclear Information System (INIS)

    Khaliq, A.; Kaushik, S.C.

    2004-01-01

    This communication presents thermodynamic methodology for the performance evaluation of combustion gas turbine cogeneration system with reheat. The energetic and exergetic efficiencies have been defined. The effects of process steam pressure and pinch point temperature used in the design of heat recovery steam generator, and reheat on energetic and exergetic efficiencies have been investigated. From the results obtained in graphs it is observed that the power to heat ratio increases with an increase in pinch point, but the first-law efficiency and second-law efficiency decreases with an increase in pinch point. The power to heat ratio and second-law efficiency increases significantly with increase in process steam pressure, but the first-law efficiency decreases with the same. Results also show that inclusion of reheat, provide significant improvement in electrical power output, process heat production, fuel-utilization (energetic) efficiency and second-law (exergetic) efficiency. This methodology may be quite useful in the selection and comparison of combined energy production systems from thermodynamic performance point of view

  13. Dry Process Fuel Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Seung; Song, K. C.; Moon, J. S. and others

    2005-04-15

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  14. Dry Process Fuel Performance Evaluation

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S. and others

    2005-04-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  15. 48 CFR 36.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Evaluation of contractor performance. 36.201 Section 36.201 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Contracting for Construction 36.201 Evaluation of contractor performance. See 42.1502(e) for the requirements...

  16. Solar energy system performance evaluation: Seasonal report for IBM System 1B, Carlsbad, New Mexico

    Science.gov (United States)

    1980-01-01

    A hot solar heating and hot water system's operational performance from April 1979 through March 1980 is evaluated. The space heating and hot water loads were near expected values for the year. Solar energy provided 43 percent of the space heating and 53 percent of the hot water energy. The system did not meet the total system solar fraction design value of 69 percent because of a combination of higher estimated space heating load than was actually encountered and the apportioning of solar energy between the space heating and the domestic hot water loads. System losses and high building temperatures also contributed to this deviation. Total net savings were 23.072 million BTUs. Most of the energy savings came during the winter months, but hot water savings were sufficient to justify running the system during the summer months.

  17. Usage of performance measurement and evaluation systems : the impact of evaluator characteristics

    OpenAIRE

    Gelderman, Maarten

    1998-01-01

    This paper discusses the relation between characteristics of the evaluating manager and the way performance measurement and evaluation information is used. First a discussion is provided about the dependent variable. It is recognized that categorization into archetypes (e.g., evaluative styles) is unsatisfactory. Instead the information content/emphasis dimensions financial-non- financial, quantitative-qualitative, process-outcome, past-future and external-internal, along with the dimension f...

  18. Evaluation of the functional performance and technical quality of an Electronic Documentation System of the Nursing Process.

    Science.gov (United States)

    de Oliveira, Neurilene Batista; Peres, Heloisa Helena Ciqueto

    2015-01-01

    To evaluate the functional performance and the technical quality of the Electronic Documentation System of the Nursing Process of the Teaching Hospital of the University of São Paulo. exploratory-descriptive study. The Quality Model of regulatory standard 25010 and the Evaluation Process defined under regulatory standard 25040, both of the International Organization for Standardization/International Electrotechnical Commission. The quality characteristics evaluated were: functional suitability, reliability, usability, performance efficiency, compatibility, security, maintainability and portability. The sample was made up of 37 evaluators. in the evaluation of the specialists in information technology, only the characteristic of usability obtained a rate of positive responses of less than 70%. For the nurse lecturers, all the quality characteristics obtained a rate of positive responses of over 70%. The staff nurses of the medical and surgical clinics with experience in using the system) and staff nurses from other units of the hospital and from other health institutions (without experience in using the system) obtained rates of positive responses of more than 70% referent to the functional suitability, usability, and security. However, performance efficiency, reliability and compatibility all obtained rates below the parameter established. the software achieved rates of positive responses of over 70% for the majority of the quality characteristics evaluated.

  19. 48 CFR 2452.216-73 - Performance evaluation plan.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Performance evaluation plan... 2452.216-73 Performance evaluation plan. As prescribed in 2416.406(e)(3), insert the following clause in all award fee contracts: Performance Evaluation Plan (AUG 1987) (a) The Government shall...

  20. Performance evaluation of three automated identification systems in detecting carbapenem-resistant Enterobacteriaceae.

    Science.gov (United States)

    He, Qingwen; Chen, Weiyuan; Huang, Liya; Lin, Qili; Zhang, Jingling; Liu, Rui; Li, Bin

    2016-06-21

    Carbapenem-resistant Enterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably, one Klebsiella pneumoniae isolate produced both IMP-4 and NDM-1. One Klebsiella oxytoca isolate produced both KPC-2 and IMP-8. Of the 81 clinical CRE isolates, 56 (69.1 %), 33 (40.7 %) and 77 (95.1 %) were identified as CRE by MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, respectively. The sensitivities/specificities of MicroScan WalkAway, Phoenix 100 and Vitek 2 were 93.8/42.4 %, 54.2/66.7 %, and 75.0/36.4 %, respectively. The MicroScan WalkAway and Viteck2 systems are more reliable in clinical identification of

  1. An accurate evaluation of the performance of asynchronous DS-CDMA systems with zero-correlation-zone coding in Rayleigh fading

    Science.gov (United States)

    Walker, Ernest; Chen, Xinjia; Cooper, Reginald L.

    2010-04-01

    An arbitrarily accurate approach is used to determine the bit-error rate (BER) performance for generalized asynchronous DS-CDMA systems, in Gaussian noise with Raleigh fading. In this paper, and the sequel, new theoretical work has been contributed which substantially enhances existing performance analysis formulations. Major contributions include: substantial computational complexity reduction, including a priori BER accuracy bounding; an analytical approach that facilitates performance evaluation for systems with arbitrary spectral spreading distributions, with non-uniform transmission delay distributions. Using prior results, augmented by these enhancements, a generalized DS-CDMA system model is constructed and used to evaluated the BER performance, in a variety of scenarios. In this paper, the generalized system modeling was used to evaluate the performance of both Walsh- Hadamard (WH) and Walsh-Hadamard-seeded zero-correlation-zone (WH-ZCZ) coding. The selection of these codes was informed by the observation that WH codes contain N spectral spreading values (0 to N - 1), one for each code sequence; while WH-ZCZ codes contain only two spectral spreading values (N/2 - 1,N/2); where N is the sequence length in chips. Since these codes span the spectral spreading range for DS-CDMA coding, by invoking an induction argument, the generalization of the system model is sufficiently supported. The results in this paper, and the sequel, support the claim that an arbitrary accurate performance analysis for DS-CDMA systems can be evaluated over the full range of binary coding, with minimal computational complexity.

  2. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain Repository

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation`s commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives set forward by the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Environmental Protection Agency (EPA). The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. As additional site and design information is generated, performance assessment analyses can be revised to become more representative of the expected conditions and remove some of the conservative assumptions necessitated by the incompleteness of site and design data. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993. These analyses have been documented in Barnard, Eslinger, Wilson and Andrews.

  3. Total system performance assessment - 1995: An evaluation of the potential Yucca Mountain Repository

    International Nuclear Information System (INIS)

    1995-11-01

    The U.S. Department of Energy (DOE) is currently investigating the feasibility of permanently disposing the nation's commercial high-level radioactive wastes (in the form of spent fuel from the over 100 electric power-generating nuclear reactors across the U.S.) and a portion of the defense high-level radioactive wastes (currently stored at federal facilities around the country) in the unsaturated tuffaceous rocks at Yucca Mountain, Nevada. Quantitative predictions based on the most current understanding of the processes and parameters potentially affecting the long-term behavior of the disposal system are used to assess the ability of the site and its associated engineered designs to meet regulatory objectives set forward by the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Environmental Protection Agency (EPA). The evaluation of the ability of the overall system to meet the performance objectives specified in the applicable regulatory standards has been termed total system performance assessment (TSPA). The aim of any total system performance assessment is to be as complete and reasonably conservative as possible and to assure that the descriptions of the predictive models and parameters are sufficient to ascertain their accuracy. Total system performance assessments evolve with time. As additional site and design information is generated, performance assessment analyses can be revised to become more representative of the expected conditions and remove some of the conservative assumptions necessitated by the incompleteness of site and design data. Previous iterations of total system performance assessment of the Yucca Mountain site and associated engineered barriers have been conducted in 1991 and 1993. These analyses have been documented in Barnard, Eslinger, Wilson and Andrews

  4. Diversity and MIMO Performance Evaluation of Common Phase Center Multi Element Antenna Systems

    Directory of Open Access Journals (Sweden)

    V. Papamichael

    2008-06-01

    Full Text Available The diversity and Multiple Input Multiple Output (MIMO performance provided by common phase center multi element antenna (CPCMEA systems is evaluated using two practical methods which make use of the realized active element antenna patterns. These patterns include both the impact of the mutual coupling and the mismatch power loss at antenna ports. As a case study, two and four printed Inverted F Antenna (IFA systems are evaluated by means of Effective Diversity Gain (EDG and Capacity (C. EDG is measured in terms of the signal-to-noise ratio (SNR enhancement at a specific outage probability and in terms of the SNR reduction for achieving a desired average bit error rate (BER. The concept of receive antenna selection in MIMO systems is also investigated and the simulation results show a 43% improvement in the 1% outage C of a reconfigurable 2x2 MIMO system over a fixed 2x2 one.

  5. Solar energy system performance evaluation. Seasonal report for Wormser, Columbia, South Carolina

    Science.gov (United States)

    1980-01-01

    The Wormser Solar Energy System's operational performance from April 1979 through March 1980 was evaluated. The space heating subsystem met 42 percent of the measured space heating load and the hot water subsystem met 23 percent of the measured hot water demand. Net electrical energy savings were 4.36 million Btu's or 1277 kwh. Fossil energy savings will increase considerably if the uncontrolled solar energy input to the building is considered.

  6. Evaluating supplier quality performance using analytical hierarchy process

    Science.gov (United States)

    Kalimuthu Rajoo, Shanmugam Sundram; Kasim, Maznah Mat; Ahmad, Nazihah

    2013-09-01

    This paper elaborates the importance of evaluating supplier quality performance to an organization. Supplier quality performance evaluation reflects the actual performance of the supplier exhibited at customer's end. It is critical in enabling the organization to determine the area of improvement and thereafter works with supplier to close the gaps. Success of the customer partly depends on supplier's quality performance. Key criteria as quality, cost, delivery, technology support and customer service are categorized as main factors in contributing to supplier's quality performance. 18 suppliers' who were manufacturing automotive application parts evaluated in year 2010 using weight point system. There were few suppliers with common rating which led to common ranking observed by few suppliers'. Analytical Hierarchy Process (AHP), a user friendly decision making tool for complex and multi criteria problems was used to evaluate the supplier's quality performance challenging the weight point system that was used for 18 suppliers'. The consistency ratio was checked for criteria and sub-criteria. Final results of AHP obtained with no overlap ratings, therefore yielded a better decision making methodology as compared to weight point rating system.

  7. Assessment and improvement of the Italian healthcare system: first evidence from a pilot national performance evaluation system.

    Science.gov (United States)

    Nuti, Sabina; Seghieri, Chiara; Vainieri, Milena; Zett, Silvia

    2012-01-01

    The Italian National Health System (NHS), established in 1978, follows a model similar to the Beveridge model developed by the British NHS (Beveridge 1942; Musgrove 2000). Like the British NHS, healthcare coverage for the Italian population is provided and financed by the government through taxes. Universal coverage provides uniform healthcare access to citizens and is the characteristic usually considered the added value of a welfare system financed by tax revenues. Nonetheless, in Italy the strong policy of decentralization, which has been taking place since the early 1990s, has gradually shifted powers from the state to the 21 Italian regions. Consequently, the state now retains limited supervisory control and continues to have overall responsibility for the NHS in order to ensure uniform and essential levels of health services across the country. In this context, it has become essential, both for the ministry and for regions, to adopt a common performance evaluation system (PES). This article reports the definition, implementation, and first evidences of a pilot PES at a national level. It shows how this PES can be viewed as a strategic tool supporting the Ministry of Health (MoH) in ensuring uniform levels of care for the population and assisting regional managers to evaluate performance in benchmarking. Finally, lessons for other health systems, based on the Italian experience, are provided.

  8. Development of on-line core performance evaluation system for 'FUGEN'

    International Nuclear Information System (INIS)

    Natori, Hisahide; Kaneto, Kunikazu; Oteru, Shigeru.

    1982-01-01

    An on-line core performance evaluation system ATROPOS has been developed in order to carry out safe and efficient reactor operation of ''FUGEN''(a heavy water moderated, boiling light water cooled, pressure tube type reactor). This system offers detailed and useful information on such items of core performance as core thermal power, power distribution and thermal operation limits. The power distribution is calculated first by using a three-dimensional nodal coupling model, employing such process data as control rod position and 10 B concentration in the D 2 O moderator. Then the calculated power distribution is corrected by local power monitor readings. An axial one-dimensional nodal coupling model, which considers radial power distribution, and a localized three-dimensional nodal coupling model are used to predict the core thermal power and the power distribution for the region surrounding the control rods respectively, within a short time in advance of control rod operation. The methods employed in this system are verified by comparison with start-up test data from the FUGEN initial core. The estimated power distribution and channel flow agree with values measured by the power calibration monitor and with channel flow converted from measured values of pressure drop, within 3 and 5% respectively, in their root mean square values. The difference in core thermal power between the predicted value and the value measured by the total power monitor is about 1% for control rod operation. (author)

  9. Performance and Complexity Evaluation of Iterative Receiver for Coded MIMO-OFDM Systems

    Directory of Open Access Journals (Sweden)

    Rida El Chall

    2016-01-01

    Full Text Available Multiple-input multiple-output (MIMO technology in combination with channel coding technique is a promising solution for reliable high data rate transmission in future wireless communication systems. However, these technologies pose significant challenges for the design of an iterative receiver. In this paper, an efficient receiver combining soft-input soft-output (SISO detection based on low-complexity K-Best (LC-K-Best decoder with various forward error correction codes, namely, LTE turbo decoder and LDPC decoder, is investigated. We first investigate the convergence behaviors of the iterative MIMO receivers to determine the required inner and outer iterations. Consequently, the performance of LC-K-Best based receiver is evaluated in various LTE channel environments and compared with other MIMO detection schemes. Moreover, the computational complexity of the iterative receiver with different channel coding techniques is evaluated and compared with different modulation orders and coding rates. Simulation results show that LC-K-Best based receiver achieves satisfactory performance-complexity trade-offs.

  10. performance-based approach to design and evaluation of nuclear security systems for Brazilian nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, Renato L. A.; Filho, Josélio S. M., E-mail: renato.tavares@cnen.gov.br, E-mail: joselio@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear. Divisão de Normas e Segurança Física; Fontes, Gladson S.; Fiel, J.C.B., E-mail: gsfontes@hotmail.com, E-mail: fiel@ime.eb.br [Instituto Militar de Engenharia (SE-7/IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    This study presents an application of a performance-based approach to definition of requirements, design and evaluation of physical protection systems for nuclear facilities. Such approach considers a probabilistic analysis of the threat, equipment, systems and response forces used to prevent, dissuade and detain malicious acts against the integrity of facilities and the nuclear materials inside them. Nowadays, in the context of Brazilian nuclear facilities licensing, a mostly prescriptive approach is adopted, which despite having advantages such as simplified inspections and homogeneous regulatory requisites amid different fuel cycle facility types, does not consider evolution, dynamism and capacities of external or internal threats to facilities and to Brazilian Nuclear Program itself, neither provides metrics to evaluate system performance facing such threats. In order to preserve actual plans and systems confidentiality, a facility hypothetical model is created, including a research reactor and a waste storage facility. It is expected that the methodology and results obtained in this study serve in the future as a basis to Brazilian nuclear operators, in elaboration process of their Physical Protection Plans, which must comply with future regulation CNEN-NN 2.01, a revision of CNEN-NE 2.01, once that regulation will include performance requisites. (author)

  11. performance-based approach to design and evaluation of nuclear security systems for Brazilian nuclear facilities

    International Nuclear Information System (INIS)

    Tavares, Renato L. A.; Filho, Josélio S. M.; Fontes, Gladson S.; Fiel, J.C.B.

    2017-01-01

    This study presents an application of a performance-based approach to definition of requirements, design and evaluation of physical protection systems for nuclear facilities. Such approach considers a probabilistic analysis of the threat, equipment, systems and response forces used to prevent, dissuade and detain malicious acts against the integrity of facilities and the nuclear materials inside them. Nowadays, in the context of Brazilian nuclear facilities licensing, a mostly prescriptive approach is adopted, which despite having advantages such as simplified inspections and homogeneous regulatory requisites amid different fuel cycle facility types, does not consider evolution, dynamism and capacities of external or internal threats to facilities and to Brazilian Nuclear Program itself, neither provides metrics to evaluate system performance facing such threats. In order to preserve actual plans and systems confidentiality, a facility hypothetical model is created, including a research reactor and a waste storage facility. It is expected that the methodology and results obtained in this study serve in the future as a basis to Brazilian nuclear operators, in elaboration process of their Physical Protection Plans, which must comply with future regulation CNEN-NN 2.01, a revision of CNEN-NE 2.01, once that regulation will include performance requisites. (author)

  12. 48 CFR 1552.209-76 - Contractor performance evaluations.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Contractor performance... 1552.209-76 Contractor performance evaluations. As prescribed in section 1509.170-1, insert the following clause in all applicable solicitations and contracts. Contractor Performance Evaluations (OCT 2002...

  13. 48 CFR 8.406-7 - Contractor Performance Evaluation.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contractor Performance... ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Federal Supply Schedules 8.406-7 Contractor Performance Evaluation. Ordering activities must prepare an evaluation of contractor performance for each...

  14. 48 CFR 1536.201 - Evaluation of contracting performance.

    Science.gov (United States)

    2010-10-01

    ... performance. 1536.201 Section 1536.201 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY... Contracting for Construction 1536.201 Evaluation of contracting performance. (a) The Contracting Officer will... will file the form in the contractor performance evaluation files which it maintains. (e) The Quality...

  15. Use of One-On Analysis to Evaluate Total System Performance of the Proposed Yucca Mountain Nuclear Waste Repository

    International Nuclear Information System (INIS)

    Saulnier, G.J. Jr.; Lee, K.P.; Mehta, S.; Sevougian, S.D.; Kalinich, D.; McNeish, J.A.

    2002-01-01

    The Yucca Mountain Site Characterization Project is currently evaluating the future performance of the proposed U.S. high-level nuclear waste repository. Using the Total System Performance Assessment (TSPA) model, a stylized analysis was conducted to evaluate the relative importance of natural and engineered barriers to movement of radionuclides from the proposed repository. These stylized ''one-on'' analyses consist of sequentially adding features, components, and processes, associated with the natural and engineered barriers, incorporated within the TSPA model and evaluating the effect of these elements on repository performance, as measured by the total mean annual dose to a reasonably maximally exposed individual. The analyses are ''stylized'' in the sense that they are performed to gain insight only. They are not meant to represent a real physical system in most cases, and in some cases allow the TSPA model to simulate results using parameter ranges outside the normal bounds of the TSPA model. In particular, the analyses provide insight into the relative contributions of repository features and processes in a way that is not possible using the full TSPA performance-assessment model. For example, in the nominal scenario of the TSPA model, the contribution of the natural system is masked by the contribution of the engineered system

  16. Performance Evaluation of Security Protocols

    DEFF Research Database (Denmark)

    Bodei, Chiara; Buchholtz, Mikael; Curti, Michele

    2005-01-01

    We use a special operational semantics which drives us in inferring quantitative measures on systems describing cryptographis cryptographic protocols. We assign rates to transitions by only looking at these labels. The rates reflect the distributed architecture running applications and the use...... of possibly different cryptosystems. We then map transition systems to Markov chains and evaluate performance of systems, using standard tools....

  17. Evaluation of new control rooms by operator performance analysis

    International Nuclear Information System (INIS)

    Mori, M; Tomizawa, T.; Tai, I.; Monta, K.; Yoshimura, S.; Hattori, Y.

    1987-01-01

    An advanced supervisory and control system called PODIA TM (Plant Operation by Displayed Information and Automation) was developed by Toshiba. Since this system utilizes computer driven CRTs as a main device for information transfer to operators, thorough system integration tests were performed at the factory and evaluations were made of operators' assessment from the initial experience of the system. The PODIA system is currently installed at two BWR power plants. Based on the experiences from the development of PODIA, a more advanced man-machine interface, Advanced-PODIA (A-PODIA), is developed. A-PODIA enhances the capabilities of PODIA in automation, diagnosis, operational guidance and information display. A-PODIA has been validated by carrying out systematic experiments with a full-scope simulator developed for the validation. The results of the experiments have been analyzed by the method of operator performance analysis and applied to further improvement of the A-PODIA system. As a feedback from actual operational experience, operator performance data in simulator training is an important source of information to evaluate human factors of a control room. To facilitate analysis of operator performance, a performance evaluation system has been developed by applying AI techniques. The knowledge contained in the performance evaluation system was elicited from operator training experts and represented as rules. The rules were implemented by employing an object-oriented paradigm to facilitate knowledge management. In conclusion, it is stated that the feedback from new control room operation can be obtained at an early stage by validation tests and also continuously by comprehensive evaluation (with the help of automated tools) of operator performance in simulator training. The results of operator performance analysis can be utilized for improvement of system design as well as operator training. (author)

  18. Synthetic and Enhanced Vision Systems for NextGen (SEVS) Simulation and Flight Test Performance Evaluation

    Science.gov (United States)

    Shelton, Kevin J.; Kramer, Lynda J.; Ellis,Kyle K.; Rehfeld, Sherri A.

    2012-01-01

    The Synthetic and Enhanced Vision Systems for NextGen (SEVS) simulation and flight tests are jointly sponsored by NASA's Aviation Safety Program, Vehicle Systems Safety Technology project and the Federal Aviation Administration (FAA). The flight tests were conducted by a team of Honeywell, Gulfstream Aerospace Corporation and NASA personnel with the goal of obtaining pilot-in-the-loop test data for flight validation, verification, and demonstration of selected SEVS operational and system-level performance capabilities. Nine test flights (38 flight hours) were conducted over the summer and fall of 2011. The evaluations were flown in Gulfstream.s G450 flight test aircraft outfitted with the SEVS technology under very low visibility instrument meteorological conditions. Evaluation pilots flew 108 approaches in low visibility weather conditions (600 ft to 2400 ft visibility) into various airports from Louisiana to Maine. In-situ flight performance and subjective workload and acceptability data were collected in collaboration with ground simulation studies at LaRC.s Research Flight Deck simulator.

  19. Channel modeling and performance evaluation of FSO communication systems in fog

    KAUST Repository

    Esmail, Maged Abdullah

    2016-07-01

    Free space optical (FSO) communication has become more exciting during the last decade. It has unregulated spectrum with a huge capacity compared to its radio frequency (RF) counterpart. Although FSO has many applications that cover indoor and outdoor environments, its widespread is humped by weather effects. Fog is classified as an extreme weather impairment that may cause link drop. Foggy channel modeling and characterization is necessary to analyze the system performance. In this paper, we first address the statistical behavior of the foggy channel based on a set of literature experimental data and develop a probability distribution function (PDF) model for fog attenuation. We then exploit our PDF model to derive closed form expressions and evaluate the system performance theoretically and numerically, in terms of average signal-to-noise ratio (SNR), and outage probability. The results show that for 10-3 outage probability and 22 dBm transmitted power, the FSO system can work over 80 m, 160 m, 310 m, and 460 m link length under dense, thick, moderate, and light fog respectively. Increasing the transmitted power will have high impact when the fog density is low. However, under very dense fog, it has almost no effect. © 2016 IEEE.

  20. Channel modeling and performance evaluation of FSO communication systems in fog

    KAUST Repository

    Esmail, Maged Abdullah; Fathallah, Habib; Alouini, Mohamed-Slim

    2016-01-01

    Free space optical (FSO) communication has become more exciting during the last decade. It has unregulated spectrum with a huge capacity compared to its radio frequency (RF) counterpart. Although FSO has many applications that cover indoor and outdoor environments, its widespread is humped by weather effects. Fog is classified as an extreme weather impairment that may cause link drop. Foggy channel modeling and characterization is necessary to analyze the system performance. In this paper, we first address the statistical behavior of the foggy channel based on a set of literature experimental data and develop a probability distribution function (PDF) model for fog attenuation. We then exploit our PDF model to derive closed form expressions and evaluate the system performance theoretically and numerically, in terms of average signal-to-noise ratio (SNR), and outage probability. The results show that for 10-3 outage probability and 22 dBm transmitted power, the FSO system can work over 80 m, 160 m, 310 m, and 460 m link length under dense, thick, moderate, and light fog respectively. Increasing the transmitted power will have high impact when the fog density is low. However, under very dense fog, it has almost no effect. © 2016 IEEE.

  1. Cooperative joint precoding in a downlink cellular system with shared relay: Design and performance evaluation

    KAUST Repository

    Kwon, JaeWoo; Park, Kihong; Ko, Youngchai; Yang, Hongchuan

    2012-01-01

    In this paper, we investigate a relay enhanced cellular system, where a relay station is located in the overlap area served by two base stations. We propose cooperative joint precoding schemes for the downlink transmission of such relay enhanced cellular system to maximize the system capacity while minimizing the interference at both the relay station and the mobile stations. We formulate the optimization problems to maximize the system capacity and design the multiuser precoding vectors at each base station and the relay station. We quantify the ergodic rate performance of the proposed multiuser precoding schemes through statistical analysis. The extensively derived ergodic expressions will facilitate the accurate performance evaluation of the proposed transmission schemes. Numerical results show that the proposed schemes can effectively cancel the interference and improve the sum rate and the outage performance for cell edge users. © 2002-2012 IEEE.

  2. Cooperative joint precoding in a downlink cellular system with shared relay: Design and performance evaluation

    KAUST Repository

    Kwon, JaeWoo

    2012-10-01

    In this paper, we investigate a relay enhanced cellular system, where a relay station is located in the overlap area served by two base stations. We propose cooperative joint precoding schemes for the downlink transmission of such relay enhanced cellular system to maximize the system capacity while minimizing the interference at both the relay station and the mobile stations. We formulate the optimization problems to maximize the system capacity and design the multiuser precoding vectors at each base station and the relay station. We quantify the ergodic rate performance of the proposed multiuser precoding schemes through statistical analysis. The extensively derived ergodic expressions will facilitate the accurate performance evaluation of the proposed transmission schemes. Numerical results show that the proposed schemes can effectively cancel the interference and improve the sum rate and the outage performance for cell edge users. © 2002-2012 IEEE.

  3. Analytical Evaluation of the Performance of Proportional Fair Scheduling in OFDMA-Based Wireless Systems

    Directory of Open Access Journals (Sweden)

    Mohamed H. Ahmed

    2012-01-01

    Full Text Available This paper provides an analytical evaluation of the performance of proportional fair (PF scheduling in Orthogonal Frequency-Division Multiple Access (OFDMA wireless systems. OFDMA represents a promising multiple access scheme for transmission over wireless channels, as it combines the orthogonal frequency division multiplexing (OFDM modulation and subcarrier allocation. On the other hand, the PF scheduling is an efficient resource allocation scheme with good fairness characteristics. Consequently, OFDMA with PF scheduling represents an attractive solution to deliver high data rate services to multiple users simultaneously with a high degree of fairness. We investigate a two-dimensional (time slot and frequency subcarrier PF scheduling algorithm for OFDMA systems and evaluate its performance analytically and by simulations. We derive approximate closed-form expressions for the average throughput, throughput fairness index, and packet delay. Computer simulations are used for verification. The analytical results agree well with the results from simulations, which show the good accuracy of the analytical expressions.

  4. Total System Performance Assessment, 1993: An evaluation of the potential Yucca Mountain repository

    International Nuclear Information System (INIS)

    Andrews, R.W.; Dale, T.F.; McNeish, J.A.

    1994-03-01

    Total System Performance Assessments are an important component in the evaluation of the suitability of Yucca Mountain, Nevada as a potential site for a mined geologic repository for the permanent disposal of high-level radioactive wastes in the United States. The Total System Performance Assessments are conducted iteratively during site characterization to identify issues which should be addressed by the characterization and design activities as well as providing input to regulatory/licensing and programmatic decisions. During fiscal years 1991 and 1992, the first iteration of Total System Performance Assessment (hereafter referred to as TSPA 1991) was completed by Sandia National Laboratories and Pacific Northwest Laboratory. Beginning in fiscal year 1993, the Civilian Radioactive Waste Management System Management and Operating Contractor was assigned the responsibility to plan, coordinate, and contribute to the second iteration of Total System Performance Assessment (hereafter referred to as TSPA 1993). This document presents the objectives, approach, assumptions, input, results, conclusions, and recommendations associated with the Management and Operating Contractor contribution to TSPA 1993. The new information incorporated in TSPA 1993 includes (1) revised estimates of radionuclide solubilities (and their thermal and geochemical dependency), (2) thermal and geochemical dependency of spent fuel waste alteration and glass dissolution rates, (3) new distribution coefficient (k d ) estimates, (4) revised estimates of gas-phase velocities and travel times, and (5) revised hydrologic modeling of the saturated zone which provides updated estimates of the advective flux through the saturated zone

  5. Total System Performance Assessment, 1993: An evaluation of the potential Yucca Mountain repository

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, R.W.; Dale, T.F.; McNeish, J.A.

    1994-03-01

    Total System Performance Assessments are an important component in the evaluation of the suitability of Yucca Mountain, Nevada as a potential site for a mined geologic repository for the permanent disposal of high-level radioactive wastes in the United States. The Total System Performance Assessments are conducted iteratively during site characterization to identify issues which should be addressed by the characterization and design activities as well as providing input to regulatory/licensing and programmatic decisions. During fiscal years 1991 and 1992, the first iteration of Total System Performance Assessment (hereafter referred to as TSPA 1991) was completed by Sandia National Laboratories and Pacific Northwest Laboratory. Beginning in fiscal year 1993, the Civilian Radioactive Waste Management System Management and Operating Contractor was assigned the responsibility to plan, coordinate, and contribute to the second iteration of Total System Performance Assessment (hereafter referred to as TSPA 1993). This document presents the objectives, approach, assumptions, input, results, conclusions, and recommendations associated with the Management and Operating Contractor contribution to TSPA 1993. The new information incorporated in TSPA 1993 includes (1) revised estimates of radionuclide solubilities (and their thermal and geochemical dependency), (2) thermal and geochemical dependency of spent fuel waste alteration and glass dissolution rates, (3) new distribution coefficient (k{sub d}) estimates, (4) revised estimates of gas-phase velocities and travel times, and (5) revised hydrologic modeling of the saturated zone which provides updated estimates of the advective flux through the saturated zone.

  6. Research on Performance Evaluation by IDSS Based on AHP

    Directory of Open Access Journals (Sweden)

    Tang Xuelian

    2013-03-01

    Full Text Available Talent resource is the primary resource. There are two sides as the starting point and foothold in this paper. One is how to evaluate the performance of science and technology talents flow by IDSS (Intelligence Decision Supporting System. Another is how to guide the innovation work of science and technology according to the evaluation results. The evaluation index on performance system has hierarchical structure. So AHP (Analytic Hierarchy Process is applied to evaluate the performance. Evaluation model is established and illustrated by the cases in this paper. It can be seen that the flow of performance is influenced by the growth rate of important scientific and technological achievements. Furthermore, some constructive suggestions are given based on the results of evaluation.

  7. Evaluating Organizational Performance: Rational, Natural, and Open System Models

    Science.gov (United States)

    Martz, Wes

    2013-01-01

    As the definition of organization has evolved, so have the approaches used to evaluate organizational performance. During the past 60 years, organizational theorists and management scholars have developed a comprehensive line of thinking with respect to organizational assessment that serves to inform and be informed by the evaluation discipline.…

  8. Disposal systems evaluations and tool development : Engineered Barrier System (EBS) evaluation.

    Energy Technology Data Exchange (ETDEWEB)

    Rutqvist, Jonny (LBNL); Liu, Hui-Hai (LBNL); Steefel, Carl I. (LBNL); Serrano de Caro, M. A. (LLNL); Caporuscio, Florie Andre (LANL); Birkholzer, Jens T. (LBNL); Blink, James A. (LLNL); Sutton, Mark A. (LLNL); Xu, Hongwu (LANL); Buscheck, Thomas A. (LLNL); Levy, Schon S. (LANL); Tsang, Chin-Fu (LBNL); Sonnenthal, Eric (LBNL); Halsey, William G. (LLNL); Jove-Colon, Carlos F.; Wolery, Thomas J. (LLNL)

    2011-01-01

    Key components of the nuclear fuel cycle are short-term storage and long-term disposal of nuclear waste. The latter encompasses the immobilization of used nuclear fuel (UNF) and radioactive waste streams generated by various phases of the nuclear fuel cycle, and the safe and permanent disposition of these waste forms in geological repository environments. The engineered barrier system (EBS) plays a very important role in the long-term isolation of nuclear waste in geological repository environments. EBS concepts and their interactions with the natural barrier are inherently important to the long-term performance assessment of the safety case where nuclear waste disposition needs to be evaluated for time periods of up to one million years. Making the safety case needed in the decision-making process for the recommendation and the eventual embracement of a disposal system concept requires a multi-faceted integration of knowledge and evidence-gathering to demonstrate the required confidence level in a deep geological disposal site and to evaluate long-term repository performance. The focus of this report is the following: (1) Evaluation of EBS in long-term disposal systems in deep geologic environments with emphasis on the multi-barrier concept; (2) Evaluation of key parameters in the characterization of EBS performance; (3) Identification of key knowledge gaps and uncertainties; and (4) Evaluation of tools and modeling approaches for EBS processes and performance. The above topics will be evaluated through the analysis of the following: (1) Overview of EBS concepts for various NW disposal systems; (2) Natural and man-made analogs, room chemistry, hydrochemistry of deep subsurface environments, and EBS material stability in near-field environments; (3) Reactive Transport and Coupled Thermal-Hydrological-Mechanical-Chemical (THMC) processes in EBS; and (4) Thermal analysis toolkit, metallic barrier degradation mode survey, and development of a Disposal Systems

  9. Disposal systems evaluations and tool development: Engineered Barrier System (EBS) evaluation

    International Nuclear Information System (INIS)

    Rutqvist, Jonny; Liu, Hui-Hai; Steefel, Carl I.; Serrano de Caro, M.A.; Caporuscio, Florie Andre; Birkholzer, Jens T.; Blink, James A.; Sutton, Mark A.; Xu, Hongwu; Buscheck, Thomas A.; Levy, Schon S.; Tsang, Chin-Fu; Sonnenthal, Eric; Halsey, William G.; Jove-Colon, Carlos F.; Wolery, Thomas J.

    2011-01-01

    Key components of the nuclear fuel cycle are short-term storage and long-term disposal of nuclear waste. The latter encompasses the immobilization of used nuclear fuel (UNF) and radioactive waste streams generated by various phases of the nuclear fuel cycle, and the safe and permanent disposition of these waste forms in geological repository environments. The engineered barrier system (EBS) plays a very important role in the long-term isolation of nuclear waste in geological repository environments. EBS concepts and their interactions with the natural barrier are inherently important to the long-term performance assessment of the safety case where nuclear waste disposition needs to be evaluated for time periods of up to one million years. Making the safety case needed in the decision-making process for the recommendation and the eventual embracement of a disposal system concept requires a multi-faceted integration of knowledge and evidence-gathering to demonstrate the required confidence level in a deep geological disposal site and to evaluate long-term repository performance. The focus of this report is the following: (1) Evaluation of EBS in long-term disposal systems in deep geologic environments with emphasis on the multi-barrier concept; (2) Evaluation of key parameters in the characterization of EBS performance; (3) Identification of key knowledge gaps and uncertainties; and (4) Evaluation of tools and modeling approaches for EBS processes and performance. The above topics will be evaluated through the analysis of the following: (1) Overview of EBS concepts for various NW disposal systems; (2) Natural and man-made analogs, room chemistry, hydrochemistry of deep subsurface environments, and EBS material stability in near-field environments; (3) Reactive Transport and Coupled Thermal-Hydrological-Mechanical-Chemical (THMC) processes in EBS; and (4) Thermal analysis toolkit, metallic barrier degradation mode survey, and development of a Disposal Systems

  10. Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety.

    Science.gov (United States)

    Giebel, Felix; Picker, Susanne M; Gathof, Birgit S

    2008-01-01

    SUMMARY: OBJECTIVE: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. DESIGN: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. RESULTS: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. CONCLUSION: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.

  11. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  12. Experimental analysis and performance evaluation of a tandem photovoltaic–thermoelectric hybrid system

    International Nuclear Information System (INIS)

    Kossyvakis, D.N.; Voutsinas, G.D.; Hristoforou, E.V.

    2016-01-01

    Highlights: • Experimental and theoretical investigation of a PV–TEG system has been conducted. • Poly-Si and dye-sensitized solar cells have been employed. • Thermoelectric generators of different thermoelement length have been tested. • A wide range considering cell’s operating temperature has been examined. - Abstract: Although photovoltaics have been established as the dominant technology considering the field of solar energy conversion systems, issues regarding their relatively low efficiency still remain practically unsolved. Very recently, the possibility of combining photovoltaic (PV) cells and thermoelectric generators (TEGs) in hybrid systems, as a means of improving the overall conversion efficiency, has attracted particular attention. In this paper, the performance of a tandem PV–TEG hybrid, employing poly-Si as well as dye-sensitized solar cells, has been examined experimentally. Thermoelectric devices of different thermoelement geometry have been tested in order to identify the corresponding performance effect. In addition, the outcomes of the experimental process have been exploited in order to evaluate the performance of the system under real operating conditions. The analysis conducted indicates that the utilization of TEGs with shorter thermoelements results in enhanced power output levels, when conditions of actual operation are considered. Moreover, although improved power output is obtained by the setup employing the polycrystalline cell, dye-sensitized technology could become particularly attractive when the incorporation of solar cells in PV–TEG hybrids operating under conditions of elevated temperature is examined.

  13. Performance evaluation of radiant cooling system application on a university building in Indonesia

    Science.gov (United States)

    Satrio, Pujo; Sholahudin, S.; Nasruddin

    2017-03-01

    The paper describes a study developed to estimate the energy savings potential of a radiant cooling system installed in an institutional building in Indonesia. The simulations were carried out using IESVE to evaluate thermal performance and energy consumption The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption and temperature distribution to determine the proportional energy savings and occupant comfort under different systems. The result was radiant cooling which integrated with a Dedicated Outside Air System (DOAS) could make 41,84% energy savings compared to the installed cooling system. The Computational Fluid Dynamics (CFD) simulation showed that a radiant system integrated with DOAS provides superior human comfort than a radiant system integrated with Variable Air Volume (VAV). Percentage People Dissatisfied was kept below 10% using the proposed system.

  14. UNIX-based operating systems robustness evaluation

    Science.gov (United States)

    Chang, Yu-Ming

    1996-01-01

    Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.

  15. Potential pros and cons of external healthcare performance evaluation systems: real-life perspectives on Iranian hospital evaluation and accreditation program.

    Science.gov (United States)

    Jaafaripooyan, Ebrahim

    2014-09-01

    Performance evaluation is essential to quality improvement in healthcare. The current study has identified the potential pros and cons of external healthcare evaluation programs, utilizing them subsequently to look into the merits of a similar case in a developing country. A mixed method study employing both qualitative and quantitative data collection and analysis techniques was adopted to achieve the study end. Subject Matter Experts (SMEs) and professionals were approached for two-stage process of data collection. Potential advantages included greater attractiveness of high accreditation rank healthcare organizations to their customers/purchasers and boosted morale of their personnel. Downsides, as such, comprised the programs' over-reliance on value judgment of surveyors, routinization and incurring undue cost on the organizations. In addition, the improved, standardized care processes as well as the judgmental nature of program survey were associated, as pros and cons, to the program investigated by the professionals. Besides rendering a tentative assessment of Iranian hospital evaluation program, the study provides those running external performance evaluations with a lens to scrutinize the virtues of their own evaluation systems through identifying the potential advantages and drawbacks of such programs. Moreover, the approach followed could be utilized for performance assessment of similar evaluation programs.

  16. Potential Benefits and Downsides of External Healthcare Performance Evaluation Systems: Real-Life Perspectives on Iranian Hospital Evaluation and Accreditation Program

    Directory of Open Access Journals (Sweden)

    Ebrahim Jaafaripooyan

    2014-09-01

    Full Text Available Background Performance evaluation is essential to quality improvement in healthcare. The current study has identified the potential pros and cons of external healthcare evaluation programs, utilizing them subsequently to look into the merits of a similar case in a developing country. Methods A mixed method study employing both qualitative and quantitative data collection and analysis techniques was adopted to achieve the study end. Subject Matter Experts (SMEs and professionals were approached for two-stage process of data collection. Results Potential advantages included greater attractiveness of high accreditation rank healthcare organizations to their customers/purchasers and boosted morale of their personnel. Downsides, as such, comprised the programs’ over-reliance on value judgment of surveyors, routinization and incurring undue cost on the organizations. In addition, the improved, standardized care processes as well as the judgmental nature of program survey were associated, as pros and cons, to the program investigated by the professionals. Conclusion Besides rendering a tentative assessment of Iranian hospital evaluation program, the study provides those running external performance evaluations with a lens to scrutinize the virtues of their own evaluation systems through identifying the potential advantages and drawbacks of such programs. Moreover, the approach followed could be utilized for performance assessment of similar evaluation programs.

  17. Performance evaluation of photovoltaic-thermosyphon system for subtropical climate application

    Energy Technology Data Exchange (ETDEWEB)

    Chow, T.T.; He, W.; Chan, A.L.S. [Division of Building Science and Technology, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR (China); Ji, J. [Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Anhui (China)

    2007-01-15

    The rapid development and sales volume of photovoltaic (PV) modules has created a promising business environment in the foreseeable future. However, the current electricity cost from PV is still several times higher than from the conventional power generation. One way to shorten the payback period is to bring in the hybrid photovoltaic-thermal (PVT) technology, which multiplies the energy outputs from the same collector surface area. In this paper, the performance evaluation of a new water-type PVT collector system is presented. The thermal collection making use of the thermosyphon principle eliminates the expense of pumping power. Experimental rigs were successfully built. A dynamic simulation model of the PVT collector system was developed and validated by the experimental measurements, together with two other similar models developed for PV module and solar hot-water collector. These were then used to predict the energy outputs and the payback periods for their applications in the subtropical climate, with Hong Kong as an example. The numerical results show that a payback period of 12 year for the PVT collector system is comparable to the side-by-side system, and is much shorter than the plain PV application. This is a great encouragement in marketing the PVT technology. (author)

  18. Performance evaluation of photovoltaic-thermosyphon system for subtropical climate application

    International Nuclear Information System (INIS)

    Chow, T.T.; He, W.; Chan, A.L.S.; Ji, J.

    2007-01-01

    The rapid development and sales volume of photovoltaic (PV) modules has created a promising business environment in the foreseeable future. However, the current electricity cost from PV is still several times higher than from the conventional power generation. One way to shorten the payback period is to bring in the hybrid photovoltaic-thermal (PVT) technology, which multiplies the energy outputs from the same collector surface area. In this paper, the performance evaluation of a new water-type PVT collector system is presented. The thermal collection making use of the thermosyphon principle eliminates the expense of pumping power. Experimental rigs were successfully built. A dynamic simulation model of the PVT collector system was developed and validated by the experimental measurements, together with two other similar models developed for PV module and solar hot-water collector. These were then used to predict the energy outputs and the payback periods for their applications in the subtropical climate, with Hong Kong as an example. The numerical results show that a payback period of 12 year for the PVT collector system is comparable to the side-by-side system, and is much shorter than the plain PV application. This is a great encouragement in marketing the PVT technology. (author)

  19. 48 CFR 3036.201 - Evaluation of contractor performance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Evaluation of contractor performance. 3036.201 Section 3036.201 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY... contractor performance. (a)(2) Performance reports shall be prepared and entered into the Contractor...

  20. Piloted Well Clear Performance Evaluation of Detect and Avoid Systems with Suggestive Guidance

    Science.gov (United States)

    Mueller, Eric; Santiago, Confesor; Watza, Spencer

    2016-01-01

    Regulations to establish operational and performance requirements for unmanned aircraft systems (UAS) are being developed by a consortium of government, industry and academic institutions (RTCA, 2013). Those requirements will apply to the new detect-and-avoid (DAA) systems and other equipment necessary to integrate UAS with the United States (U.S) National Airspace System (NAS) and will be determined according to their contribution to the overall safety case. That safety case requires demonstration that DAA-equipped UAS collectively operating in the NAS meet an airspace safety threshold (AST). Several key gaps must be closed in order to link equipment requirements to an airspace safety case. Foremost among these is calculation of the systems risk ratio, the degree to which a particular system mitigates violation of an aircraft separation standard (FAA, 2013). The risk ratio of a DAA system, in combination with risk ratios of other collision mitigation mechanisms, will determine the overall safety of the airspace measured in terms of the number of collisions per flight hour. It is not known what the effectiveness is of a pilot-in-the-loop DAA system or even what parameters of the DAA system most improve the pilots ability to maintain separation. The relationship between the DAA system design and the overall effectiveness of the DAA system that includes the pilot, expressed as a risk ratio, must be determined before DAA operational and performance requirements can be finalized. Much research has been devoted to integrating UAS into non-segregated airspace (Dalamagkidis, 2009, Ostwald, 2007, Gillian, 2012, Hesselink, 2011, Santiago, 2015, Rorie 2015 and 2016). Several traffic displays intended for use as part of a DAA system have gone through human-in-the-loop simulation and flight-testing. Most of these evaluations were part of development programs to produce a deployable system, so it is unclear how to generalize particular aspects of those designs to general

  1. Evaluation of high-performance computing software

    Energy Technology Data Exchange (ETDEWEB)

    Browne, S.; Dongarra, J. [Univ. of Tennessee, Knoxville, TN (United States); Rowan, T. [Oak Ridge National Lab., TN (United States)

    1996-12-31

    The absence of unbiased and up to date comparative evaluations of high-performance computing software complicates a user`s search for the appropriate software package. The National HPCC Software Exchange (NHSE) is attacking this problem using an approach that includes independent evaluations of software, incorporation of author and user feedback into the evaluations, and Web access to the evaluations. We are applying this approach to the Parallel Tools Library (PTLIB), a new software repository for parallel systems software and tools, and HPC-Netlib, a high performance branch of the Netlib mathematical software repository. Updating the evaluations with feed-back and making it available via the Web helps ensure accuracy and timeliness, and using independent reviewers produces unbiased comparative evaluations difficult to find elsewhere.

  2. Evaluation of ejector performance for an organic Rankine cycle combined power and cooling system

    International Nuclear Information System (INIS)

    Zhang, Kun; Chen, Xue; Markides, Christos N.; Yang, Yong; Shen, Shengqiang

    2016-01-01

    Highlights: • The performance of an ejector in an Organic Rankine Cycle and ejector refrigeration cycle (EORC) was evaluated. • The achieved entrainment ratio and COP of an EORC system is affected significantly by the evaporator conditions (such as temperature, pressure and flow rate). • An optimum distance of 6 mm nozzle position was found that ensures a maximum entrainment ratio, the best efficiency and lowest loss in the ejector. • A reduced total pressure loss between the nozzle inlet and exit leads to a lower energy loss, a higher entrainment ratio and better overall ejector performance. - Abstract: Power-generation systems based on organic Rankine cycles (ORCs) are well suited and increasingly employed in the conversion of thermal energy from low temperature heat sources to power. These systems can be driven by waste heat, for example from various industrial processes, as well as solar or geothermal energy. A useful extension of such systems involves a combined ORC and ejector-refrigeration cycle (EORC) that is capable, at low cost and complexity, of producing useful power while having a simultaneous capacity for cooling that is highly desirable in many applications. A significant thermodynamic loss in such a combined energy system takes place in the ejector due to unavoidable losses caused by irreversible mixing in this component. This paper focuses on the flow and transport processes in an ejector, in order to understand and quantify the underlying reasons for these losses, as well as their sensitivity to important design parameters and operational variables. Specifically, the study considers, beyond variations to the geometric design of the ejector, also the role of changing the external conditions across this component and how these affect its performance; this is not only important in helping develop ejector designs in the first instance, but also in evaluating how the performance may shift (in fact, deteriorate) quantitatively when the device

  3. Evaluating performance of local case-mix system by international comparison: a case study in Beijing, China.

    Science.gov (United States)

    Jian, Wei-Yan; Lu, Ming; Cui, Tao; Hu, Mu

    2011-01-01

    Case-mix is an important tool for health planning and management in many countries. As a major developing country, China is considering the introduction of the case-mix system in the health reform. Beijing, the capital of China, developed a local case-mix version whose performance needs to be evaluated before utilization. The objective of this study was to evaluate the performance of the case-mix system developed in Beijing by comparing it with those used in Australia and the U.S.A. A total of 1.3 million inpatient records from 154 hospitals in Beijing in 2008 were grouped respectively using three case-mix systems: (i) Beijing Diagnosis Related Groups (BJ-DRGs); (ii) US-based All Patient DRGs; and (iii) Australian Refined DRGs. Coefficient of variation (CV) and reduction in variance (RIV) were used to measure the performance of DRGs system. The BJ-DRGs produced the best CV and RIV results for expenditure. However, at the level of Major Diagnostic Category (MDC), three MDCs of BJ-DRGs gave the poorest RIVs for both expenditure and length of stay. Although the performance of BJ-DRGs was acceptable, further revision and improvement is needed. Comparisons with other mature DRGs versions can assist in identifying the improvement priorities of the local version. Copyright © 2011 John Wiley & Sons, Ltd.

  4. Computer performance evaluation of FACOM 230-75 computer system, (2)

    International Nuclear Information System (INIS)

    Fujii, Minoru; Asai, Kiyoshi

    1980-08-01

    In this report are described computer performance evaluations for FACOM230-75 computers in JAERI. The evaluations are performed on following items: (1) Cost/benefit analysis of timesharing terminals, (2) Analysis of the response time of timesharing terminals, (3) Analysis of throughout time for batch job processing, (4) Estimation of current potential demands for computer time, (5) Determination of appropriate number of card readers and line printers. These evaluations are done mainly from the standpoint of cost reduction of computing facilities. The techniques adapted are very practical ones. This report will be useful for those people who are concerned with the management of computing installation. (author)

  5. Development of human performance evaluation methods and systems for human factors validation in an advanced control room

    International Nuclear Information System (INIS)

    Ha, Jun Su

    2008-02-01

    Advanced control room (ACR) human-machine interface (HMI) design of advanced nuclear power plants (NPPs) such as APR (advanced power reactor)-1400 can be validated through performance-based tests to determine whether it acceptably supports safe operation of the plant. In this paper, plant performance, personnel task performance, situation awareness, workload, teamwork, and anthropometric/ physiological factor are considered as factors for the human performance evaluation. For development of measures in each of the factors, measures generally used in various industries and empirically proven to be useful are adopted as main measures with some modifications. In addition, helpful measures are developed as complementary measures in order to overcome some of the limitations associated with the main measures. The development of the measures is addressed based on the theoretical and empirical background and also based on the regulatory guidelines. A computerized system, which is called HUPESS (human performance evaluation support system), is developed based on the measures developed in this paper. The development of HUPESS is described with respect to the system configuration, the development process, and integrated measurement, evaluation, and analysis. HUPESS supports evaluators (or experimenters) to effectively measure, analyze, and evaluate the human performance for the HMI design validation in ACRs. Hence HUPESS is expected to be used as an effective tool for the human factors validation in the ACR of Shin Kori 3 and 4 NPPs (APR-1400 type) which are under construction in South-Korea. Also two measures of attentional-resource effectiveness based on cost-benefit analysis are developed. One of them is Fixation to Importance Ratio (FIR) which represents the attentional resources spent on an information source compared to the importance of the information source. The other measure is selective attention effectiveness (SAE) which incorporates the FIRs for all information

  6. A State-Based Modeling Approach for Efficient Performance Evaluation of Embedded System Architectures at Transaction Level

    Directory of Open Access Journals (Sweden)

    Anthony Barreteau

    2012-01-01

    Full Text Available Abstract models are necessary to assist system architects in the evaluation process of hardware/software architectures and to cope with the still increasing complexity of embedded systems. Efficient methods are required to create reliable models of system architectures and to allow early performance evaluation and fast exploration of the design space. In this paper, we present a specific transaction level modeling approach for performance evaluation of hardware/software architectures. This approach relies on a generic execution model that exhibits light modeling effort. Created models are used to evaluate by simulation expected processing and memory resources according to various architectures. The proposed execution model relies on a specific computation method defined to improve the simulation speed of transaction level models. The benefits of the proposed approach are highlighted through two case studies. The first case study is a didactic example illustrating the modeling approach. In this example, a simulation speed-up by a factor of 7,62 is achieved by using the proposed computation method. The second case study concerns the analysis of a communication receiver supporting part of the physical layer of the LTE protocol. In this case study, architecture exploration is led in order to improve the allocation of processing functions.

  7. Performance evaluation of the insurance companies based on AHP

    Science.gov (United States)

    Lu, Manhong; Zhu, Kunping

    2018-04-01

    With the entry of foreign capital, China's insurance industry is under increasing pressure of competition. The performance of a company is the external manifestation of its comprehensive strength. Therefore, the establishment of a scientific evaluation system is of practical significance for the insurance companies. In this paper, based on the financial and non-financial indicators of the companies, the performance evaluation system is constructed by means of the analytic hierarchy process (AHP). In the system, the weights of the indicators which represent the impact on the performance of the companies will be calculated by the process. The evaluation system is beneficial for the companies to realize their own strengths and weaknesses, so as to take steps to enhance the core competitiveness of the companies.

  8. Integrated and visual performance evaluation model for thermal systems and its application to an HTGR cogeneration system

    International Nuclear Information System (INIS)

    Qi, Zhang; Yoshikawa, Hidekazu; Ishii, Hirotake; Shimoda, Hiroshi

    2010-01-01

    An integrated and visual model EXCEM-MFM (EXergy, Cost, Energy and Mass - Multilevel Flow Model) has been proposed in this study to comprehensively analyze and evaluate the performances of thermal systems by coupling two models: EXCEM model and MFM. In the EXCEM-MFM model, MFM is used to provide analysis frameworks for exergy, cost, energy and mass four parameters, and EXCEM is used to calculate the flow values of these four parameters for MFM based on the provided framework. In this study, we used the tools and technologies of computer science and software engineering to materialize the model. Moreover, the feasibility and application potential of this proposed EXCEM-MFM model has been demonstrated by the example application of a comprehensive performance study of a typical High Temperature Gas Reactor (HTGR) cogeneration system by taking into account the thermodynamic and economic perspectives. (author)

  9. Performance evaluation of portable HPGe with in situ object counting system (ISOCS) in direct thyroid radiobioassay

    Energy Technology Data Exchange (ETDEWEB)

    Park, Min Seok; Kwon, Tae Eun; Pak, Min Jung; Park, Se Young; Ha, Wi Ho; Jin, Young Woo [National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2016-12-15

    To evaluate the internal radiation dose, various methods are required to identify and quantify radionuclides in human body. Internal contamination monitoring related with the radioiodine is generally performed by direct radiobioassay which used scintillator-based thyroid monitor. Recently, a semiconductor material such as high purity germanium (HPGe) has been used for in vivo radiobioassay. In this study, broad energy germanium (BEGe) which was a kind of HPGe was used for thyroid radiobioassay. BEGe shows good performance in the radiobioassay due to its high energy resolution. In Situ Object Counting System (ISOCS) was the efficiency calibration software developed by Canberra Industries. The efficiency calibration with this system was performed by the Monte Carlo method. It was useful method as alternative method of conventional calibration. The purpose of this study is to evaluate the performance of measuring radioiodine by means of ISOCS which is equipped with the portable HPG(Falcon 5000, Canberra Industries) in direct thyroid radiobioassay. The ISOCS software ensured compliance with the performance criteria in the radioiodine measurement. These results of participating in intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassay with more convenient procedure.

  10. Evaluation of real-time operating system for small-scale embedded systems

    International Nuclear Information System (INIS)

    Dayang Norhayati Abang Jawawi; Rosbi Mamat

    1999-01-01

    In this paper, the performance of some real-time operating systems for small-scale embedded systems are evaluated based on some criteria. The evaluation is performed qualitatively and quantitatively. The evaluation results based on a case study on an engineering application will be presented. (author)

  11. NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric

    Science.gov (United States)

    Companies | Energy Systems Integration Facility | NREL NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric Companies NREL Evaluates Advanced Solar Inverter Performance for Hawaiian performance and impacts of today's advanced solar inverters, as well as proprietary feedback to the inverter

  12. Performance Evaluation of a Solar Adsorption Refrigeration System with a Wing Type Compound Parabolic Concentrator

    Directory of Open Access Journals (Sweden)

    Muhammad Umair

    2014-03-01

    Full Text Available Simulation study of a solar adsorption refrigeration system using a wing type compound parabolic concentrator (CPC is presented. The system consists of the wing type collector set at optimum angles, adsorption bed, a condenser and a refrigerator. The wing type collector captures the solar energy efficiently in the morning and afternoon and provides the effective temperature for a longer period of time compared to that achieved by a linear collector. The objectives of the study were to evaluate the system behavior, the effect of wing length, and to compare the performance of the systems with wing type and linear CPCs. A detailed dynamic simulation model was developed based on mass and energy balance equations. The simulation results show that the system performance with wing type CPC increases by up to 6% in the summer and up to 2% in the winter, compared to the performance with a linear CPC having same collector length. The ice production also increases up to 13% in the summer with the wing type CPC. This shows that the wing type CPC is helpful to increase the performance of the system compared to the linear CPC with the same collector length and without the need for tracking.

  13. Studies on TOP executive performance evaluation system of Chinese listed companies

    Institute of Scientific and Technical Information of China (English)

    WANG De-wu 王德武; JIANG Guo-qing 姜国庆; JIANG Shuo 姜硕; HUANG Allen R

    2004-01-01

    According to the development status of Chinese listed companies, it is important to implement a stock option incentive plan for the top executives (TE) of the companies. It is necessary to establish a set of indices to evaluate a top executive's performance and award performance-based stock options to them scientifically and reasonably.This thesis sets indices from the perspective of the top executive's behaviour and results,which differs from the traditional methods performance evaluation.

  14. Proposed evaluation framework for assessing operator performance with multisensor displays

    Science.gov (United States)

    Foyle, David C.

    1992-01-01

    Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

  15. Performance measurement, modeling, and evaluation of integrated concurrency control and recovery algorithms in distributed data base systems

    Energy Technology Data Exchange (ETDEWEB)

    Jenq, B.C.

    1986-01-01

    The performance evaluation of integrated concurrency-control and recovery mechanisms for distributed data base systems is studied using a distributed testbed system. In addition, a queueing network model was developed to analyze the two phase locking scheme in the distributed testbed system. The combination of testbed measurement and analytical modeling provides an effective tool for understanding the performance of integrated concurrency control and recovery algorithms in distributed database systems. The design and implementation of the distributed testbed system, CARAT, are presented. The concurrency control and recovery algorithms implemented in CARAT include: a two phase locking scheme with distributed deadlock detection, a distributed version of optimistic approach, before-image and after-image journaling mechanisms for transaction recovery, and a two-phase commit protocol. Many performance measurements were conducted using a variety of workloads. A queueing network model is developed to analyze the performance of the CARAT system using the two-phase locking scheme with before-image journaling. The combination of testbed measurements and analytical modeling provides significant improvements in understanding the performance impacts of the concurrency control and recovery algorithms in distributed database systems.

  16. Performance Parameters for Grid-Connected PV Systems

    Energy Technology Data Exchange (ETDEWEB)

    Marion, B.; Adelstein, J.; Boyle, K.; Hayden, H.; Hammond, B.; Fletcher, T.; Canada, B.; Narang, D.; Shugar, D.; Wenger, H.; Kimber, A.; Mitchell, L.; Rich, G.; Townsend, T.

    2005-02-01

    The use of appropriate performance parameters facilitates the comparison of grid-connected photovoltaic (PV) systems that may differ with respect to design, technology, or geographic location. Four performance parameters that define the overall system performance with respect to the energy production, solar resource, and overall effect of system losses are the following: final PV system yield, reference yield, performance ratio, and PVUSA rating. These performance parameters are discussed for their suitability in providing desired information for PV system design and performance evaluation and are demonstrated for a variety of technologies, designs, and geographic locations. Also discussed are methodologies for determining system a.c. power ratings in the design phase using multipliers developed from measured performance parameters.The use of appropriate performance parameters facilitates the comparison of grid-connected photovoltaic (PV) systems that may differ with respect to design, technology, or geographic location. Four performance parameters that define the overall system performance with respect to the energy production, solar resource, and overall effect of system losses are the following: final PV system yield, reference yield, performance ratio, and PVUSA rating. These performance parameters are discussed for their suitability in providing desired information for PV system design and performance evaluation and are demonstrated for a variety of technologies, designs, and geographic locations. Also discussed are methodologies for determining system a.c. power ratings in the design phase using multipliers developed from measured performance parameters.

  17. Performance evaluation of photoacoustic oximetry imaging systems using a dynamic blood flow phantom with tunable oxygen saturation

    Science.gov (United States)

    Vogt, William C.; Zhou, Xuewen; Andriani, Rudy; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2018-02-01

    Photoacoustic Imaging (PAI) is an emerging technology with strong potential for broad clinical applications from breast cancer detection to cerebral monitoring due to its ability to compute maps of blood oxygen saturation (SO2) distribution in deep tissues using multispectral imaging. However, no well-validated consensus test methods currently exist for evaluating oximetry-specific performance characteristics of PAI devices. We have developed a phantombased flow system capable of rapid SO2 adjustment to serve as a test bed for elucidation of factors impacting SO2 measurement and quantitative characterization of device performance. The flow system is comprised of a peristaltic pump, membrane oxygenator, oxygen and nitrogen gas, and in-line oxygen, pH, and temperature sensors that enable real-time estimation of SO2 reference values. Bovine blood was delivered through breast-relevant tissue phantoms containing vessel-mimicking fluid channels, which were imaged using a custom multispectral PAI system. Blood was periodically drawn for SO2 measurement in a clinical-grade CO-oximeter. We used this flow phantom system to evaluate the impact of device parameters (e.g.,wavelength-dependent fluence corrections) and tissue parameters (e.g. fluid channel depth, blood SO2, spectral coloring artifacts) on oximetry measurement accuracy. Results elucidated key challenges in PAI oximetry and device design trade-offs, which subsequently allowed for optimization of system performance. This approach provides a robust benchtop test platform that can support PAI oximetry device optimization, performance validation, and clinical translation, and may inform future development of consensus test methods for performance assessment of photoacoustic oximetry imaging systems.

  18. A conceptual framework for evaluation of public health and primary care system performance in iran.

    Science.gov (United States)

    Jahanmehr, Nader; Rashidian, Arash; Khosravi, Ardeshir; Farzadfar, Farshad; Shariati, Mohammad; Majdzadeh, Reza; Akbari Sari, Ali; Mesdaghinia, Alireza

    2015-01-26

    The main objective of this study was to design a conceptual framework, according to the policies and priorities of the ministry of health to evaluate provincial public health and primary care performance and to assess their share in the overall health impacts of the community. We used several tools and techniques, including system thinking, literature review to identify relevant attributes of health system performance framework and interview with the key stakeholders. The PubMed, Scopus, web of science, Google Scholar and two specialized databases of Persian language literature (IranMedex and SID) were searched using main terms and keywords. Following decision-making and collective agreement among the different stakeholders, 51 core indicators were chosen from among 602 obtained indicators in a four stage process, for monitoring and evaluation of Health Deputies. We proposed a conceptual framework by identifying the performance area for Health Deputies between other determinants of health, as well as introducing a chain of results, for performance, consisting of Input, Process, Output and Outcome indicators. We also proposed 5 dimensions for measuring the performance of Health Deputies, consisting of efficiency, effectiveness, equity, access and improvement of health status. The proposed Conceptual Framework illustrates clearly the Health Deputies success in achieving best results and consequences of health in the country. Having the relative commitment of the ministry of health and Health Deputies at the University of Medical Sciences is essential for full implementation of this framework and providing the annual performance report.

  19. Measurement and evaluation systems for NPP commissioning

    International Nuclear Information System (INIS)

    Elko, Marek

    2006-01-01

    Standard core monitoring and information systems are designed with an emphasis on normal operation of nuclear power plant. Their purpose is to provide necessary support for reactor operators and other operating personnel during the fuel cycle. After each fuel reloading, and to the larger extent during the plant commissioning, a variety of start-up tests need to be carried out and evaluated. Sampling periods, accuracy and communication delays of standard systems are not always suitable for test performance and evaluation. For technical and safety reasons, the access to standard monitoring and information systems is very limited. Non-Standard Measurement and Evaluation Systems are highly specialized devices designed with an emphasis on start-up tests performance and evaluation. They are capable of high frequency sampling, processing and communication of hundreds of technological signals with required accuracy and low communication delay. All technological signals needed for the test performance and evaluation are collected from various systems, concentrated in one system and fully accessible to a test leader, a reactor physicist or other users. In addition, Non-Standard Measurement and Evaluation Systems can perform other tasks like data storing and presentation, data distribution to other systems or external computers via network, reactivity calculations, etc. Structure of such systems can vary, but generally it is a mixture of two basic concepts: a mobile system and a stationary system. A basic description of hardware structure and software equipment of Non-Standard Measurement and Evaluation Systems is given in the paper (Authors)

  20. High performance APCS conceptual design and evaluation scoping study

    International Nuclear Information System (INIS)

    Soelberg, N.; Liekhus, K.; Chambers, A.; Anderson, G.

    1998-02-01

    This Air Pollution Control System (APCS) Conceptual Design and Evaluation study was conducted to evaluate a high-performance (APC) system for minimizing air emissions from mixed waste thermal treatment systems. Seven variations of high-performance APCS designs were conceptualized using several design objectives. One of the system designs was selected for detailed process simulation using ASPEN PLUS to determine material and energy balances and evaluate performance. Installed system capital costs were also estimated. Sensitivity studies were conducted to evaluate the incremental cost and benefit of added carbon adsorber beds for mercury control, specific catalytic reduction for NO x control, and offgas retention tanks for holding the offgas until sample analysis is conducted to verify that the offgas meets emission limits. Results show that the high-performance dry-wet APCS can easily meet all expected emission limits except for possibly mercury. The capability to achieve high levels of mercury control (potentially necessary for thermally treating some DOE mixed streams) could not be validated using current performance data for mercury control technologies. The engineering approach and ASPEN PLUS modeling tool developed and used in this study identified APC equipment and system performance, size, cost, and other issues that are not yet resolved. These issues need to be addressed in feasibility studies and conceptual designs for new facilities or for determining how to modify existing facilities to meet expected emission limits. The ASPEN PLUS process simulation with current and refined input assumptions and calculations can be used to provide system performance information for decision-making, identifying best options, estimating costs, reducing the potential for emission violations, providing information needed for waste flow analysis, incorporating new APCS technologies in existing designs, or performing facility design and permitting activities

  1. Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 1 Cooling Season Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Malhotra, Mini [ORNL; Munk, Jeffrey D [ORNL

    2016-08-01

    This report provides second-year cooling season test results for the multi-year project titled “Evaluation of Variable Refrigeration Flow (VRF) System on Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP).” The purpose of the second-year project was to (1) evaluate the full- and partload performance of VRF systems compared with an existing baseline heating, ventilation, and airconditioning (HVAC) system, which is a conventional rooftop unit (RTU) variable-air-volume (VAV) system with electric resistance heating and (2) use hourly building energy simulation to evaluate the energy savings potential of using VRF systems in major US cities. The second-year project performance period was from July 2015 through June 2016.

  2. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  3. Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    Science.gov (United States)

    Yang, J; Sekhar, S C; Cheong, K W D; Raphael, B

    2015-04-01

    In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system has been developed, which aims to exhaust the exhaled air as much as possible from around the infected person (IP). The PV-PE system was studied experimentally for a particular healthcare setting based on a typical consultation room geometry and four different medical consultation positions of an IP and a healthy person (HP). Experiments using two types of tracer gases were conducted to evaluate two types of PE: Top-PE and Shoulder-PE under two different background ventilation systems: Mixing Ventilation and Displacement Ventilation. Personalized exposure effectiveness, intake fraction (iF) and exposure reduction (ε) were used as indices to evaluate the PV-PE system. The results show that the combined PV-PE system for the HP achieves the lowest intake fraction; and the use of PE system for the IP alone shows much better performance than using PV system for the HP alone. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Performance evaluation of multi-state degraded systems with minimal repairs and imperfect preventive maintenance

    International Nuclear Information System (INIS)

    Soro, Isaac W.; Nourelfath, Mustapha; Ait-Kadi, Daoud

    2010-01-01

    In this paper, we develop a model for evaluating the availability, the production rate and the reliability function of multi-state degraded systems subjected to minimal repairs and imperfect preventive maintenance. The status of the system is considered to degrade with use. These degradations may lead to decrease in the system efficiency. It is assumed that the system can consecutively degrade into several discrete states, which are characterized by different performance rates, ranging from perfect functioning to complete failure. The latter is observed when the degradation level reaches a certain critical threshold such as the system efficiency may decrease to an unacceptable limit. In addition, the system can fail randomly from any operational or acceptable state and can be repaired. This repair action brings the system to its previous operational state without affecting its failure rate (i.e., minimal repair). The used preventive maintenance policy suggests that if the system reaches the last acceptable degraded state, it is brought back to one of the states with higher efficiency. Considering customer demand as constant, the system is modeled as a continuous-time Markov process to assess its instantaneous and stationary performance measures. A numerical example is given to illustrate the proposed model.

  5. Performance evaluation of PRIDE UNDA system with feed material of pyroprocessing

    Energy Technology Data Exchange (ETDEWEB)

    An, Su Jung; Seo, Hee; Lee, Chae Hun; Ahn, Seong Kyu; Park, Se Hwan; Ku, Jeong Hoe [Nonproliferation System Research Division, KAERI, Daejeon (Korea, Republic of)

    2016-12-15

    The PRIDE (PyRoprocessing Integrated inactive DEmonstration facility) provides unique opportunities not only to develop process technologies but also to test various types of safeguards equipment for nuclear material accountancy (NMA), containment and surveillance (C/S), as well as process monitoring. In this regard, we developed a UNDA (Unified Non-Destructive Assay) system by incorporating three different non-destructive assay (NDA) techniques, i.e., neutron, gamma-ray, and mass measurements, for the testing of NMA of PRIDE. One of the main advantages of the UNDA is reducing measurement time and systematic error related to sample handling and placement by integrating the NDA techniques. The {sup 235}U mass can be determined from the {sup 238}U mass and uranium enrichment ({sup 235}U/{sup 238}U). The {sup 238}U mass is acquired from total neutron counting using neutron detection module of UNDA, with the information on the spontaneous fission neutron yield of {sup 238}U and neutron detection efficiency of the system. Total sample mass is measured by using the mass balance. In our previous studies, the UNDA was developed and characterized for a calibration source. In this study, the UNDA was installed in PRIDE facility, and the performance of the UNDA was evaluated with feed material of oxide reduction process. In this study, the performance of the UNDA was evaluated with feed material of oxide reduction process: UO2 porous pellets made of DU. The neutron net count rate was obtained as functions of 238U mass. The measured net count rate fitted by linear regression showed good linearity. In addition, the 238U mass of unknown source was determined using the information of the detection efficiency and count rate obtained from the UNDA.

  6. An adaptive toolkit for image quality evaluation in system performance test of digital breast tomosynthesis

    Science.gov (United States)

    Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde

    2017-03-01

    Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.

  7. Performance evaluation of project management system based on combination of EFQM and QFD

    Directory of Open Access Journals (Sweden)

    Amin Ahmadi Digehsara

    2018-09-01

    Full Text Available Project management system (PMS is broadly recognized as the effective management tool for several organizations. European Foundation of Quality Management (EFQM model provides some advantages for companies to be successful in current competitive environment. This paper is based on the combination of EFQM and Quality function deployment (QFD in order to eval-uate a PMS in an aviation organization. Although, an integration of these models increases the system complexity, the implementation of EFQM-QFD helps us identify all noteworthy success factors of PMS within the organization. In addition, the current status of PMS performance is evaluated based on these factors. This study attempts to find out how organizations ought to be managed to take full advantage of PMS tools. This study uses a comprehensive questionnaire to find all critical factors influencing on the success of the organization. The method of this paper is implemented in an organization in aviation industry with several management departments.

  8. Configuring Balanced Scorecards for Measuring Health System Performance: Evidence from 5 Years' Evaluation in Afghanistan

    Science.gov (United States)

    Edward, Anbrasi; Kumar, Binay; Kakar, Faizullah; Salehi, Ahmad Shah; Burnham, Gilbert; Peters, David H.

    2011-01-01

    Background In 2004, Afghanistan pioneered a balanced scorecard (BSC) performance system to manage the delivery of primary health care services. This study examines the trends of 29 key performance indicators over a 5-year period between 2004 and 2008. Methods and Findings Independent evaluations of performance in six domains were conducted annually through 5,500 patient observations and exit interviews and 1,500 provider interviews in >600 facilities selected by stratified random sampling in each province. Generalized estimating equation (GEE) models were used to assess trends in BSC parameters. There was a progressive improvement in the national median scores scaled from 0–100 between 2004 and 2008 in all six domains: patient and community satisfaction of services (65.3–84.5, pscorecard reconfigurations are needed to integrate effectiveness and efficiency measures and accommodate changes in health systems policy and strategy architecture to ensure its continued relevance and effectiveness as a comprehensive health system performance measure. The process of BSC design and implementation can serve as a valuable prototype for health policy planners managing performance in similar health care contexts. Please see later in the article for the Editors' Summary PMID:21814499

  9. Bus Accessing Performance Evaluation for Plant Control System

    International Nuclear Information System (INIS)

    Chung, Yang Mook

    2005-01-01

    The PCS system with 44 communication masters(CM) which process more than 30000 input and output signals, designed and manufactured by HF Contorols Corporation, is applied to UCN No. 5,6 nuclear power plant for the first time. In the process of system operation, the numerous problems have been issued and investigated and fixed so far. To share a understanding for digital communication system, UCN PCS communication methods are described herein through comparisons between the different priority techniques as well as the results of performance tests

  10. Who Should Evaluate Teachers' Performance at Schools?

    Science.gov (United States)

    Tabancali, Erkan

    2017-01-01

    Correct determination of whether or not the objectives are achieved or of the level of achievement of the objectives is vital in educational organizations. In this context, one of the indicators of how teachers serve the organizational objectives is performance evaluation. In Turkish Educational System, the evaluation of the performance of…

  11. Evaluation of the Performance of Routine Information System Management (PRISM framework: evidence from Uganda

    Directory of Open Access Journals (Sweden)

    Aqil Anwer

    2010-07-01

    Full Text Available Abstract Background Sound policy, resource allocation and day-to-day management decisions in the health sector require timely information from routine health information systems (RHIS. In most low- and middle-income countries, the RHIS is viewed as being inadequate in providing quality data and continuous information that can be used to help improve health system performance. In addition, there is limited evidence on the effectiveness of RHIS strengthening interventions in improving data quality and use. The purpose of this study is to evaluate the usefulness of the newly developed Performance of Routine Information System Management (PRISM framework, which consists of a conceptual framework and associated data collection and analysis tools to assess, design, strengthen and evaluate RHIS. The specific objectives of the study are: a to assess the reliability and validity of the PRISM instruments and b to assess the validity of the PRISM conceptual framework. Methods Facility- and worker-level data were collected from 110 health care facilities in twelve districts in Uganda in 2004 and 2007 using records reviews, structured interviews and self-administered questionnaires. The analysis procedures include Cronbach's alpha to assess internal consistency of selected instruments, test-retest analysis to assess the reliability and sensitivity of the instruments, and bivariate and multivariate statistical techniques to assess validity of the PRISM instruments and conceptual framework. Results Cronbach's alpha analysis suggests high reliability (0.7 or greater for the indices measuring a promotion of a culture of information, RHIS tasks self-efficacy and motivation. The study results also suggest that a promotion of a culture of information influences RHIS tasks self-efficacy, RHIS tasks competence and motivation, and that self-efficacy and the presence of RHIS staff have a direct influence on the use of RHIS information, a key aspect of RHIS performance

  12. Professional performance evaluation within the Romanian administrative system

    Directory of Open Access Journals (Sweden)

    Cristina MANOLE

    2010-12-01

    Full Text Available The current economic crisis, manifested in the entire world, highlights the need for sustained involvement of the local and regional authorities in each country, in conceiving and implementing Community policies (which already exist at European level having an essential role in implementing the economic plans achievement. This view was shared by all European Union Member States, of which Romania is part, since 2007. Therefore, the economic crisis which is reflected in the Romanian society today, requires prompt and sustained intervention by the authorities in the execution of the economic recovery plan, implying the community strategies, due to sharply budgetary expenses cut, which is found in all European countries. In order to achieve this major objective, the Romanian authorities should have qualified and properly motivated personnel through an adequate remuneration, according to the training, skills, responsibilities and especially individual performance obtained at each position, as it happens in most developed countries of the European Union. In this context, this study approaches the issues related to the performance evaluation of the public sector’s employees. Considering the fact that strengthening and developing the human resources segment is a strategic goal of the Romanian administration for the period 2008 - 2013, which will lead to modernizing it and making it more efficient (at both central and local level, the personnel performance evaluation, at the organizational level represents a fundamental activity from the human resources’ management perspective.

  13. Conceptual Designs for the Performance Improvement of APR1400 SIT and Preliminary Performance Evaluation

    International Nuclear Information System (INIS)

    Chu, In-Cheol; Kwon, Tae-Soon; Song, Chul-Hwa

    2008-01-01

    Some evolutionary type PWRs such as APR1400 and APWR adopt advanced safety injection tank (SIT). The SIT of APR1400 has a fluidic device (FD) which passively controls ECC water injection flow rate into reactor coolant system during refill and reflood phases of LB-LOCA (i.e., a high injection flow rate during the refill phase and a low injection flow rate during the reflood phase). The benefit of the FD is the elimination of the function of low pressure safety injection pump from the safety injection system. The flow controlling performance of the APR1400 FD was evaluated using a prototypical full-scale test facility, called VAPER (Valve Performance Evaluation Rig). Even though the performance of the APR1400 FD satisfied major design and licensing requirements, further improvement of the performance is expected such as the extension of total injection period, the delay of nitrogen gas discharge. Several conceptual designs have been being drawn out in order to improve the performance of the APR1400 SIT. The performance of some designs was evaluated using a small scale SIT test rig. The present paper introduces some of the conceptual designs and shows the performance evaluation experimental results

  14. Cooling performance and evaluation of automotive refrigeration system for a passenger car

    Science.gov (United States)

    Prajitno, Deendarlianto, Majid, Akmal Irfan; Mardani, Mahardeka Dhias; Wicaksono, Wendi; Kamal, Samsul; Purwanto, Teguh Pudji; Fauzun

    2016-06-01

    A new design of automotive refrigeration system for a passenger car was proposed. To ensure less energy consumption and optimal thermal comfort, the performance of the system were evaluated. This current research was aimed to evaluate the refrigeration characteristics of the system for several types of cooling load. In this present study, a four-passenger wagon car with 1500 cc gasoline engine that equipped by a belt driven compressor (BDC) was used as the tested vehicle. To represent the tropical condition, a set of lamps and wind sources are installed around the vehicle. The blower capacity inside a car is varied from 0.015 m/s to 0.027 m/s and the compressor speed is varied at variable 820, 1400, and 2100 rpm at a set temperature of 22°C. A set of thermocouples that combined by data logger were used to measure the temperature distribution. The system uses R-134a as the refrigerant. In order to determine the cooling capacity of the vehicle, two conditions were presented: without passengers and full load conditions. As the results, cooling capacity from any possible heating sources and transient characteristics of temperature in both systems for the cabin, engine, compressor, and condenser are presented in this work. As the load increases, the outlet temperature of evaporator also increases due to the increase of condensed air. This phenomenon also causes the increase of compressor work and compression ratio which associated to the addition of specific volume in compressor inlet.

  15. Characterizing performance improvement in primary care systems in Mesoamerica: A realist evaluation protocol.

    Science.gov (United States)

    Munar, Wolfgang; Wahid, Syed S; Curry, Leslie

    2018-01-03

    Background . Improving performance of primary care systems in low- and middle-income countries (LMICs) may be a necessary condition for achievement of universal health coverage in the age of Sustainable Development Goals. The Salud Mesoamerica Initiative (SMI), a large-scale, multi-country program that uses supply-side financial incentives directed at the central-level of governments, and continuous, external evaluation of public, health sector performance to induce improvements in primary care performance in eight LMICs. This study protocol seeks to explain whether and how these interventions generate program effects in El Salvador and Honduras. Methods . This study presents the protocol for a study that uses a realist evaluation approach to develop a preliminary program theory that hypothesizes the interactions between context, interventions and the mechanisms that trigger outcomes. The program theory was completed through a scoping review of relevant empirical, peer-reviewed and grey literature; a sense-making workshop with program stakeholders; and content analysis of key SMI documents. The study will use a multiple case-study design with embedded units with contrasting cases. We define as a case the two primary care systems of Honduras and El Salvador, each with different context characteristics. Data will be collected through in-depth interviews with program actors and stakeholders, documentary review, and non-participatory observation. Data analysis will use inductive and deductive approaches to identify causal patterns organized as 'context, mechanism, outcome' configurations. The findings will be triangulated with existing secondary, qualitative and quantitative data sources, and contrasted against relevant theoretical literature. The study will end with a refined program theory. Findings will be published following the guidelines generated by the Realist and Meta-narrative Evidence Syntheses study (RAMESES II). This study will be performed

  16. Performance evaluation on aquatic product cold-chain logistics

    Directory of Open Access Journals (Sweden)

    Wenbing Wu

    2015-11-01

    Full Text Available Purpose: The requirements for high quality and diversification aquatic products are increasing with the improvement of Chinese living standard. However, the distribution between place of production and place of consumption are uneven, which results in large cold-chain logistics demand for aquatic products. At present, the low-level development of cold chain logistics has a bad impact on the circulation of aquatic products in China. So it is very urgent to develop cold-chain logistics in China. Design/methodology/approach: In order to do this, we apply performance evaluation, a well-known management tool, to study Chinese aquatic product cold-chain logistics. In this paper we first propose SISP(Subjects, Indexes, Standards, and Phases of performance evaluation model and ACSSN model(Aquatic product, Customer, Supply Chain, Society, and Node enterprises of supply chain for aquatic products cold-chain logistics performance evaluation. Then an ANP-Fuzzy method is proposed to evaluate the operational performance of Shandong Oriental Ocean Sci-Tech Co., Ltd. Furthermore, a system dynamic model is built to simulate the impact of temperature on the profits in aquatic products cold-chain sales section. Findings: We find out within a reasonable temperature range, lower temperature brings higher profit level. Also, performance improvement methods are proposed and the simulation of performance evaluation system is developed. Practical implications: Our findings can help to improve the level of aquatic product cold-chain logistics in China. Originality/value: The paper proposes the SISP (Subjects, Indexes, Standards, and Phases of performance evaluation model and ACSSN model (Aquatic product, Customer, Supply Chain, Society, and Node enterprises of supply chain for aquatic products cold-chain logistics performance evaluation.

  17. Evaluation of the performance of the OneTouch Select Plus blood glucose test system against ISO 15197:2013.

    Science.gov (United States)

    Setford, Steven; Smith, Antony; McColl, David; Grady, Mike; Koria, Krisna; Cameron, Hilary

    2015-01-01

    Assess laboratory and in-clinic performance of the OneTouch Select(®) Plus test system against ISO 15197:2013 standard for measurement of blood glucose. System performance assessed in laboratory against key patient, environmental and pharmacologic factors. User performance was assessed in clinic by system-naïve lay-users. Healthcare professionals assessed system accuracy on diabetes subjects in clinic. The system demonstrated high levels of performance, meeting ISO 15197:2013 requirements in laboratory testing (precision, linearity, hematocrit, temperature, humidity and altitude). System performance was tested against 28 interferents, with an adverse interfering effect only being recorded for pralidoxime iodide. Clinic user performance results fulfilled ISO 15197:2013 accuracy criteria. Subjects agreed that the color range indicator clearly showed if they were low, in-range or high and helped them better understand glucose results. The system evaluated is accurate and meets all ISO 15197:2013 requirements as per the tests described. The color range indicator helped subjects understand glucose results and supports patients in following healthcare professional recommendations on glucose targets.

  18. Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

    Science.gov (United States)

    Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G

    2014-11-01

    We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of the Terminal Sequencing and Spacing System for Performance Based Navigation Arrivals

    Science.gov (United States)

    Thipphavong, Jane; Jung, Jaewoo; Swenson, Harry N.; Martin, Lynne; Lin, Melody; Nguyen, Jimmy

    2013-01-01

    NASA has developed the Terminal Sequencing and Spacing (TSS) system, a suite of advanced arrival management technologies combining timebased scheduling and controller precision spacing tools. TSS is a ground-based controller automation tool that facilitates sequencing and merging arrivals that have both current standard ATC routes and terminal Performance-Based Navigation (PBN) routes, especially during highly congested demand periods. In collaboration with the FAA and MITRE's Center for Advanced Aviation System Development (CAASD), TSS system performance was evaluated in human-in-the-loop (HITL) simulations with currently active controllers as participants. Traffic scenarios had mixed Area Navigation (RNAV) and Required Navigation Performance (RNP) equipage, where the more advanced RNP-equipped aircraft had preferential treatment with a shorter approach option. Simulation results indicate the TSS system achieved benefits by enabling PBN, while maintaining high throughput rates-10% above baseline demand levels. Flight path predictability improved, where path deviation was reduced by 2 NM on average and variance in the downwind leg length was 75% less. Arrivals flew more fuel-efficient descents for longer, spending an average of 39 seconds less in step-down level altitude segments. Self-reported controller workload was reduced, with statistically significant differences at the p less than 0.01 level. The RNP-equipped arrivals were also able to more frequently capitalize on the benefits of being "Best-Equipped, Best- Served" (BEBS), where less vectoring was needed and nearly all RNP approaches were conducted without interruption.

  20. Performance evaluation and parametric optimum design of a molten carbonate fuel cell-thermophotovoltaic cell hybrid system

    International Nuclear Information System (INIS)

    Yang, Zhimin; Liao, Tianjun; Zhou, Yinghui; Lin, Guoxing; Chen, Jincan

    2016-01-01

    Highlights: • A molten carbonate fuel cell-thermophotovoltaic cell hybrid system is established. • The performance characteristics of the hybrid system are systematically evaluated. • The optimal regions of the power output density and efficiency are determined. • The values of key parameters at the maximum power output density are calculated. • The proposed system is proved to have advantages over other hybrid systems. - Abstract: A new model of the hybrid system composed of a molten carbonate fuel cell (MCFC) and a thermophotovoltaic cell (TPVC) is proposed to recovery the waste heat produced by the MCFC. Expressions for the power output and the efficiency of the hybrid system are analytically derived. The performance characteristics of the hybrid system are evaluated. It is found that when the current density of the MCFC, voltage output of the TPVC, electrode area ratio of the MCFC to the TPVC, and energy gap of the material in the photovoltaic cell are optimally chosen, the maximum power output density of the hybrid system is obviously larger than that of the single MCFC. Moreover, the improved percentages of the maximum power output density of the proposed model relative to that of the single MCFC are calculated for differently operating temperatures of the MCFC and are compared with those of some MCFC-based hybrid systems reported in the literature, and consequently, the advantages of the MCFC-TPVC hybrid system are revealed.

  1. A Conceptual Framework for Evaluation of Public Health and Primary Care System Performance in Iran

    Science.gov (United States)

    Jahanmehr, Nader; Rashidian, Arash; Khosravi, Ardeshir; Farzadfar, Farshad; Shariati, Mohammad; Majdzadeh, Reza; Sari, Ali Akbari; Mesdaghinia, Alireza

    2015-01-01

    Introduction: The main objective of this study was to design a conceptual framework, according to the policies and priorities of the ministry of health to evaluate provincial public health and primary care performance and to assess their share in the overall health impacts of the community. Methods: We used several tools and techniques, including system thinking, literature review to identify relevant attributes of health system performance framework and interview with the key stakeholders. The PubMed, Scopus, web of science, Google Scholar and two specialized databases of Persian language literature (IranMedex and SID) were searched using main terms and keywords. Following decision-making and collective agreement among the different stakeholders, 51 core indicators were chosen from among 602 obtained indicators in a four stage process, for monitoring and evaluation of Health Deputies. Results: We proposed a conceptual framework by identifying the performance area for Health Deputies between other determinants of health, as well as introducing a chain of results, for performance, consisting of Input, Process, Output and Outcome indicators. We also proposed 5 dimensions for measuring the performance of Health Deputies, consisting of efficiency, effectiveness, equity, access and improvement of health status. Conclusion: The proposed Conceptual Framework illustrates clearly the Health Deputies success in achieving best results and consequences of health in the country. Having the relative commitment of the ministry of health and Health Deputies at the University of Medical Sciences is essential for full implementation of this framework and providing the annual performance report. PMID:25946937

  2. Performance evaluation of computer and communication systems

    CERN Document Server

    Le Boudec, Jean-Yves

    2011-01-01

    … written by a scientist successful in performance evaluation, it is based on his experience and provides many ideas not only to laymen entering the field, but also to practitioners looking for inspiration. The work can be read systematically as a textbook on how to model and test the derived hypotheses on the basis of simulations. Also, separate parts can be studied, as the chapters are self-contained. … the book can be successfully used either for self-study or as a supplementary book for a lecture. I believe that different types of readers will like it: practicing engineers and resea

  3. Evaluation criteria for enhanced solar–coal hybrid power plant performance

    International Nuclear Information System (INIS)

    Zhao, Yawen; Hong, Hui; Jin, Hongguang

    2014-01-01

    Attention has been directed toward hybridizing solar energy with fossil power plants since the 1990s to improve reliability and efficiency. Appropriate evaluation criteria were important in the design and optimization of solar–fossil hybrid systems. Two new criteria to evaluate the improved thermodynamic performances in a solar hybrid power plant were developed in this study. Correlations determined the main factors influencing the improved thermodynamic performances. The proposed criteria can be used to effectively integrate solar–coal hybridization systems. Typical 100 MW–1000 MW coal-fired power plants hybridized with solar heat at approximately 300 °C, which was used to preheat the feed water before entering the boiler, were evaluated using the criteria. The integration principle of solar–coal hybrid systems was also determined. The proposed evaluation criteria may be simple and reasonable for solar–coal hybrid systems with multi-energy input, thus directing system performance enhancement. - Highlights: • New criteria to evaluate the solar hybrid power plant were developed. • Typical solar–coal hybrid power plants were evaluated using the criteria. • The integration principle of solar–coal hybrid systems was determined. • The benefits of the solar–coal hybrid system are enhanced at lower solar radiation

  4. Evaluation of the performance in the solar assisted heat pump system; Taiyonetsu riyo heat pump system no seino hyoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y [Osaka Institute of Technology, Osaka (Japan)

    1996-10-27

    Performance of a solar heating system with a hydrothermal source heat pump was evaluated and compared with that of a direct solar heating system. The sun-dependency rates ({Sigma}D and {Sigma}H)of the direct system and heat pump (HP)-provided system were expressed as a function of the rate ({alpha}) of the auxiliary heat against the collected heat and as a function of the performance coefficient and {alpha}, respectively. When the sun-dependency rates are compared, it is found that the HP-provided system is the more advantageous when {Sigma}H/{Sigma}D>1. The relationship between the {alpha}`s of the two systems was clarified and computation was performed to compare the sun-dependency rates on condition that the two are equal in the heat collecting area. Although the sun-dependence rate cannot be elevated to 100% in the HP-provided system, it achieves a sun-dependency rate higher than that of the direct system even when the heat collecting area is small. In cases where the building is economically limited, for instance, with respect to the area for solar collector installation, it is advantageous to employ the HP-provided system. 5 figs., 1 tab.

  5. System Modeling and Trust Evaluation of Distributed Systems

    OpenAIRE

    Alhadad , Nagham; Serrano-Alvarado , Patricia; Busnel , Yann; Lamarre , Philippe

    2015-01-01

    International audience; Nowadays, digital systems are connected through complex architectures. These systems involve persons, physical and digital resources such that we can consider that a system consists of elements from two worlds, the social world and the digital world, and their relations. Users perform activities like chatting, buying, sharing data, etc. Evaluating and choosing appropriate systems involve aspects like functionality, performance, QoS, ease of use, or price. Recently, tru...

  6. Developing a Teacher Evaluation Model: The Impact of Teachers’ Attitude toward the Performance Evaluation System (PES on Job Satisfaction and Organizational Commitment with the Mediating Role of Teachers’ Sense of Efficacy

    Directory of Open Access Journals (Sweden)

    Behrooz Saljooghi

    2016-05-01

    Full Text Available The objective of this paper was to design, develop and evaluate a causal model of teachers’ attitude toward the performance evaluation system (PES with the mediating role of teachers’ sense of efficacy on job satisfaction and organizational commitment. The study population included all teachers of male-only high schools in Tehran. 117 teachers were selected as the sample population using availability sampling. The present study is an applied research in terms of its objective and a descriptive research in terms of its data collection method. Furthermore, the study uses a correlational research design through structural equation modeling. In order to measure the study variables, the following questionnaires were used: Teachers’ Attitude toward Performance Evaluation, Teachers’ Sense of Efficacy, Job Satisfaction and Organizational Commitment. The results showed that teachers’ attitude toward the performance evaluation system had a significant positive effect on job satisfaction, organizational commitment and self-efficacy. Also, teachers’ sense of efficacy had a significant positive effect on job satisfaction. Moreover, the results showed that teachers’ attitude to the performance evaluation system had a positive and significant effect on organizational commitment with the mediating role of self-efficacy. Thus, the present study verified the causal model of teachers’ attitude toward the performance evaluation system with the mediating role of teachers’ sense of efficacy. Finally, the structural equation modeling reflects the positive impact of teachers’ attitude toward Iran’s Ministry of Education’s employee performance evaluation system on job satisfaction, sense of efficacy and organizational commitment.

  7. Performance power evaluation of DC fan cooling system for PV panel by using ANSYS CFX

    Science.gov (United States)

    Syafiqah, Z.; Amin, N. A. M.; Irwan, Y. M.; Irwanto, M.; Leow, W. Z.; Amelia, A. R.

    2017-09-01

    A research has been conducted to find the optimum combination for DC fan air cooling system of photovoltaic (PV) panel. During normal operation of PV panel, it is estimated that only 15 % of solar radiation is converted into electrical energy. Meanwhile, the rest of the solar radiation is converted into heat energy which affects the performance of the PV panel. Therefore, the aim of this research is to investigate the performance power evaluation of DC fan cooling system for PV panel by using ANSYS CFX. The effect of airflow configuration of DC fan has been investigated. This is to analyze whether the airflow circulation of DC fan cause a change towards the maximum temperature of PV panel. Besides, the impact of varying number of DC fans attached at the back of PV panel is evaluated. The result of airflow circulation of DC fan has been discussed. Meanwhile, with the increment number of DC fans, the PV panel temperature drops significantly. As a conclusion, the optimum number of DC fans is two with the combination of inlet airflow.

  8. Performance Evaluation of an In-Wheel Motor Cooling System in an Electric Vehicle/Hybrid Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Dong Hyun Lim

    2014-02-01

    Full Text Available High power and miniaturization of motors in an in-wheel drive system, which is installed inside the wheels of a vehicle, are required for directly driving the wheels. In addition, an efficient cooling system is required to ensure high driving performance and durability. This study experimentally evaluated the heat dissipation performance of a 35-kW-class large-capacity in-wheel motor equipped with an internal-circulation-type oil-cooling system that exhibits high cooling performance and can be easily miniaturized to this motor. Temperatures of the coil and stator core of cooling systems with and without a radiator were measured in real time under in-wheel motor driving conditions. It was found that operating the cooling system at a continuous-rating maximum speed without the radiator was difficult. We confirmed that under continuous-rating base speed and continuous-rating maximum speed driving conditions, the cooling system with the radiator showed thermally stable operation. Furthermore, under maximum-rating base speed and maximum-rating maximum speed driving conditions, the cooling system with the radiator provided additional driving times of approximately 22 s and 2 s, respectively.

  9. Actual performance and characteristic of a grid connected photovoltaic power system in the tropics: A short term evaluation

    International Nuclear Information System (INIS)

    Khatib, Tamer; Sopian, Kamaruzzaman; Kazem, Hussein A.

    2013-01-01

    Highlights: • We analyzed an actual performance of grid connected PV system. • We derived accurate models for the system based on the actual performance. • We assist the electricity productively of the proposed system. - Abstract: This paper presents a field operation experience for a grid connected PV system under tropical climate. The system is consisted of a 5 kWp photovoltaic (PV) array and a 6 kW DC/AC inverter. The operation performance data are recorded in order to develop accurate mathematical models for the system as well as to evaluate the productivity of the system. The experiment results show that, the average PV performance (the ratio of the theoretical performance to the actual performance) is 73.12% while the average inverter performance (the ratio of the theoretical inverter efficiency to the actual inverter efficiency) is 98.56%. Moreover, it is found that the daily yield factor of the PV system is 2.51 kW h/kWp day while, the capacity factor is 10.47%. However, it is concluded that the productivity of the system is below the prospected rate and thus, an inspection of the system must be done in order to diagnose the problem of the system’s low productivity. This paper presents worthwhile information for those who are interested in PV system installation in Malaysia and nearby country

  10. Performance evaluation of control room HVAC and air cleaning systems under accident conditions

    International Nuclear Information System (INIS)

    Almerico, F.; Machiels, A.J.; Ornberg, S.C.; Lahti, G.P.

    1985-01-01

    In light water reactors, control rooms and technical support centers must be designed to provide habitable environments in accordance with the requirements specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. Therefore, the effectiveness of HVAC and air cleaning system designs with respect to plant operator protection has to be evaluated by the system designer. Guidance for performing the analysis has been previously given in ANSI/ASME N509-1980 as well as in presentations at past Air Cleaning Conferences. The previous work is extended and the methodology used in a generic, interactive computer program that performs Main Control Room and Technical Support Center (TSC) habitability analyses for LWR nuclear power plants is presented. For given accident concentrations of radionuclides or hazardous gases in the outdoor air intakes and plant spaces surrounding the Main Control Room (or TSC), the program models the performance of the HVAC and air cleaning system designs, and determines control room (or TSC) contaminant concentrations and plant operator protection factors. Calculated or actual duct leakage, air cleaning efficiency, and airborne contamination are taken into account. Flexibility of the model allows for the representation of most control rooms (or TSC) and associated HVAC and air cleaning system conceptual designs that have been used by the US architect/engineers. The program replaced tedious calculations to determine the effects of HVAC ductwork and equipment leakage and permits (1) parametric analyses of various HVAC system design options early in the conceptual phase of a project, and (2) analysis of the effects of leakage test results on contaminant room concentrations, and therefore operator doses

  11. User Performance Evaluation of Four Blood Glucose Monitoring Systems Applying ISO 15197:2013 Accuracy Criteria and Calculation of Insulin Dosing Errors.

    Science.gov (United States)

    Freckmann, Guido; Jendrike, Nina; Baumstark, Annette; Pleus, Stefan; Liebing, Christina; Haug, Cornelia

    2018-04-01

    The international standard ISO 15197:2013 requires a user performance evaluation to assess if intended users are able to obtain accurate blood glucose measurement results with a self-monitoring of blood glucose (SMBG) system. In this study, user performance was evaluated for four SMBG systems on the basis of ISO 15197:2013, and possibly related insulin dosing errors were calculated. Additionally, accuracy was assessed in the hands of study personnel. Accu-Chek ® Performa Connect (A), Contour ® plus ONE (B), FreeStyle Optium Neo (C), and OneTouch Select ® Plus (D) were evaluated with one test strip lot. After familiarization with the systems, subjects collected a capillary blood sample and performed an SMBG measurement. Study personnel observed the subjects' measurement technique. Then, study personnel performed SMBG measurements and comparison measurements. Number and percentage of SMBG measurements within ± 15 mg/dl and ± 15% of the comparison measurements at glucose concentrations performed by lay-users. The study was registered at ClinicalTrials.gov (NCT02916576). Ascensia Diabetes Care Deutschland GmbH.

  12. VISA-2 - a general, vulnerability-oriented method for evaluating the performance of integrated safeguards/security systems at nuclear facilities

    International Nuclear Information System (INIS)

    Harris, L.; Owel, W.R.

    1981-01-01

    This paper discusses the VISA (Vulnerability of Integrated Safeguards Analysis) method, developed in 1976-77 for the Nuclear Regulatory Commission, and which has been adapted more recently to a broader range of uses. The performance of VISA systems is evaluated in terms of how they perform as an integrated safeguards/security system. The resulting method has been designated VISA-2. 7 refs

  13. Performance Monitoring and Evaluation in Botswana’s Public Service: Achievements and Challenges

    Directory of Open Access Journals (Sweden)

    Dorothy Mpabanga

    2016-03-01

    Full Text Available The paper aims to explore the implementation of performance monitoring and evaluation tools used in Botswana’s public service. The paper also identifies achievements and challenges of implementing performance monitoring and evaluation system and suggests ways for improvement. This paper uses secondary data sources. The paper reveals lack of performance monitoring and evaluation skills, poor supervision, poor conditions of service and a poor work ethic as some of the factors contributing to ineffective use of performance monitoring and evaluation tools in the service. Leadership commitment and support, benchmarking reforms, training and education, developed administrative and governance structures as well as well-defined public policy and program formulation and implementation processes are some of the success factors to enhanced performance management and evaluation systems in Botswana. The paper argues for adoption of a developmental-led model in order to enhance existing performance monitoring and evaluation system that would improve implementation of government policies and programs. Botswana has been striving to excel in service delivery through performance monitoring and evaluation oriented reforms.

  14. Balanced scorecard-based performance evaluation of Chinese county hospitals in underdeveloped areas.

    Science.gov (United States)

    Gao, Hongda; Chen, He; Feng, Jun; Qin, Xianjing; Wang, Xuan; Liang, Shenglin; Zhao, Jinmin; Feng, Qiming

    2018-05-01

    Objective Since the Guangxi government implemented public county hospital reform in 2009, there have been no studies of county hospitals in this underdeveloped area of China. This study aimed to establish an evaluation indicator system for Guangxi county hospitals and to generate recommendations for hospital development and policymaking. Methods A performance evaluation indicator system was developed based on balanced scorecard theory. Opinions were elicited from 25 experts from administrative units, universities and hospitals and the Delphi method was used to modify the performance indicators. The indicator system and the Topsis method were used to evaluate the performance of five county hospitals randomly selected from the same batch of 2015 Guangxi reform pilots. Results There were 4 first-level indicators, 9 second-level indicators and 36 third-level indicators in the final performance evaluation indicator system that showed good consistency, validity and reliability. The performance rank of the hospitals was B > E > A > C > D. Conclusions The performance evaluation indicator system established using the balanced scorecard is practical and scientific. Analysis of the results based on this indicator system identified several factors affecting hospital performance, such as resource utilisation efficiency, medical service price, personnel structure and doctor-patient relationships.

  15. MV-Switchgear Performance Evaluation of Electrical System at RSG-GAS after by Refunctioning

    International Nuclear Information System (INIS)

    T-Sulsistyo; T-Komarudin; Kiswanto; Y- Andriyanto

    2005-01-01

    Switchgear represents equipment link functioning to decide or connect source ration especial energy of PLN with building RSG-GAS distribution system burden. This system is provided with equipment circuit breaker (PMT) and disconnecting switch (PMS), which aim to the insulation, controlling, and protection electrical system RSG-GAS and equipment. Evaluation Method used by that is by perceiving nominal tension condition, nominal current, performance normal good switchgear in a condition, treatment and also trouble condition and also calculate change temperature effect of electric fire bow. Pursuant to calculation result, for the mean current 800 A, room; chamber temperature 24 o C, tension 24 kV, current disconnection time link to shorten 3 second, obtained temperature of equal to 90.5 o C (T1), and room temperature 40 o C obtained by temperature of equal to 108.5 o C (T2), so that of average temperature equal to 4.63 o C. While for the mean current 1250 A, room temperature 24 o C, tension 24 kV, current disconnection time link to shorten 3 second, obtained temperature equal to 282 o C (T1), and room temperature 40 o C obtained temperature equal to 298 o C (T2), so that average temperature equal to 4.0 o C. Result of evaluation job indicates that switchgear of electrical system RSG-GAS after re-functioning function goodness. (author)

  16. Towards unified performance measures for evaluating nuclear safeguard systems: mathematical foundations and formal comparison of existing models

    International Nuclear Information System (INIS)

    Corynen, G.C.

    1979-01-01

    An important step in the analysis of large-scale systems is the development of economical and meaningful measures of system performance. In the literature on analysis of nuclear safeguard systems, many performance measures have been advanced, but their interrelationships and their relevance to overall system objectives have not received attention commensurate with the effort spent in developing detailed safeguard models. The work reported here is an attempt to improve the development and evaluation of performance measures for nuclear safeguard systems. This work falls into three main areas. First, we develop a new framework which provides an initial basis for defining and structuring performance measures. To demonstrate that this framework allows a clear understanding of the purposes of nuclear safeguard systems, we employ it to state various safeguard questions clearly and concisely. The framework reflects the rough subsystem structure of safeguard systems - the detection and response subsystems - and formally accommodates various safeguard models. We especially emphasize two of these models which are under development at Lawrence Livermore Laboratory, the structured assessment approach (SAA) and the systems vulnerability assessment method (SVAM). Second, we examine some performance measures presently used in the nuclear safeguards area and in reliability theory in general. Some of these we accept and modify to obtain system performance measures that are an additive combination of subsystem performance measures, a very convenient form indeed. Others we reject as impractical and meaningless. Finally, we determine some common features between the SAA and SVAM models by formally comparing these models in our framework

  17. Performance evaluation of four different methods for circulating water in commercial-scale, split-pond aquaculture systems

    Science.gov (United States)

    The split-pond consists of a fish-culture basin that is connected to a waste-treatment lagoon by two conveyance structures. Water is circulated between the two basins with high-volume pumps and many different pumping systems are being used on commercial farms. Pump performance was evaluated with fou...

  18. Combining UML2 Application and SystemC Platform Modelling for Performance Evaluation of Real-Time Embedded Systems

    Directory of Open Access Journals (Sweden)

    Qu Yang

    2008-01-01

    Full Text Available Abstract Future mobile devices will be based on heterogeneous multiprocessing platforms accommodating several stand-alone applications. The network-on-chip communication and device networking combine the design challenges of conventional distributed systems and resource constrained real-time embedded systems. Interoperable design space exploration for both the application and platform development is required. Application designer needs abstract platform models to rapidly check the feasibility of a new feature or application. Platform designer needs abstract application models for defining platform computation and communication capacities. We propose a layered UML application/workload and SystemC platform modelling approach that allow application and platform to be modelled at several levels of abstraction, which enables early performance evaluation of the resulting system. The overall approach has been experimented with a mobile video player case study, while different load extraction methods have been validated by applying them to MPEG-4 encoder, Quake2 3D game, and MP3 decoder case studies previously.

  19. Performance evaluation of multi-channel wireless mesh networks with embedded systems.

    Science.gov (United States)

    Lam, Jun Huy; Lee, Sang-Gon; Tan, Whye Kit

    2012-01-01

    Many commercial wireless mesh network (WMN) products are available in the marketplace with their own proprietary standards, but interoperability among the different vendors is not possible. Open source communities have their own WMN implementation in accordance with the IEEE 802.11s draft standard, Linux open80211s project and FreeBSD WMN implementation. While some studies have focused on the test bed of WMNs based on the open80211s project, none are based on the FreeBSD. In this paper, we built an embedded system using the FreeBSD WMN implementation that utilizes two channels and evaluated its performance. This implementation allows the legacy system to connect to the WMN independent of the type of platform and distributes the load between the two non-overlapping channels. One channel is used for the backhaul connection and the other one is used to connect to the stations to wireless mesh network. By using the power efficient 802.11 technology, this device can also be used as a gateway for the wireless sensor network (WSN).

  20. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    International Nuclear Information System (INIS)

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files

  1. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files.

  2. Electronic prescribing: criteria for evaluating handheld prescribing systems and an evaluation of a new, handheld, wireless wide area network (WWAN) prescribing system.

    Science.gov (United States)

    Goldblum, O M

    2001-02-01

    The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to

  3. Real-Time Communications in Autonomic Networks: System Implementation and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    C. Tselios

    2012-01-01

    Full Text Available This paper describes the design and prototype implementation of a communication platform aiming to provide voice and video communication in a distributed networking environment. Performance considerations and network characteristics have also been taken into account in order to provide the set of properties dictated by the sensitive nature and the real-time characteristics of the targeted application scenarios. The proposed system has been evaluated both by experimental means as well as subjective tests taken by an extensive number of users. The results show that the proposed platform operates seamlessly in two hops, while in the four hops scenario, audio and video are delivered with marginal distortion. The conducted survey indicates that the user experience in terms of Quality of Service has obtained higher scores in the scenario with the two hops.

  4. Evaluation of Variable Refrigerant Flow Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory s Flexible Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehl, Anthony C [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-06-01

    A research project “Evaluation of Variable Refrigerant Flow (VRF) Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory’s (ORNL’s) Flexible Research Platform” was performed to (1) install and validate the performance of Samsung VRF systems compared with the baseline rooftop unit (RTU) variable-air-volume (VAV) system and (2) evaluate the enhanced control algorithm for the VRF system on the two-story flexible research platform (FRP) in Oak Ridge, Tennessee. Based on the VRF system designed by Samsung and ORNL, the system was installed from February 18 through April 15, 2014. The final commissioning and system optimization were completed on June 2, 2014, and the initial test for system operation was started the following day, June 3, 2014. In addition, the enhanced control algorithm was implemented and updated on June 18. After a series of additional commissioning actions, the energy performance data from the RTU and the VRF system were monitored from July 7, 2014, through February 28, 2015. Data monitoring and analysis were performed for the cooling season and heating season separately, and the calibrated simulation model was developed and used to estimate the energy performance of the RTU and VRF systems. This final report includes discussion of the design and installation of the VRF system, the data monitoring and analysis plan, the cooling season and heating season data analysis, and the building energy modeling study

  5. Evaluation of the technical performance of three different commercial digital breast tomosynthesis systems in the clinical environment

    NARCIS (Netherlands)

    Rodriguez Ruiz, A.; Castillo, M.; Garayoa, J.; Chevalier, M.

    2016-01-01

    The aim of this work was to research and evaluate the performance of three different digital breast tomosynthesis (DBT) systems in the clinical environment (Siemens Mammomat Inspiration, Hologic Selenia Dimensions, and Fujifilm Amulet Innovality). The characterization included the study of the

  6. Evaluation of Strategies to Improve the Thermal Performance of Steel Frames in Curtain Wall Systems

    Directory of Open Access Journals (Sweden)

    Ji Hyun Oh

    2016-12-01

    Full Text Available Recently, metal curtain wall systems have been widely used in high-rise buildings due to many advantages, including being lightweight, rapid construction, and aesthetic features. Since the metal frame may lead to lower energy performance, thermal discomfort, and condensation risk due to the high thermal conductivity, its thermal performance can be important for the improvement of the overall thermal performance of the curtain wall system, as well as the energy efficiency of the building envelope. This study aims to evaluate variety of design strategies to improve the thermal performance of steel curtain wall frames. Five base cases and three further steps were selected for two different head profile shapes based on a state-of-the art technology review, and their thermal transmittances were calculated through simulations according to the ISO 12631 standard which is an international standard for calculating thermal transmittance of curtain wall system. Measured results that were obtained from hot-box tests were compared with the calculated results to validate the simulation method of this study. The shape of the head profile did not strongly influence the overall thermal transmittance, and the choice of strategies for the rabbet space was more important. More effective strategies could be decided according to the steps for variation development. This result can serve as a guideline for the design of high-performance curtain wall frames.

  7. Evaluation of the dynamic and kinematic performance of the THOR dummy : neck performance

    NARCIS (Netherlands)

    Hoofman, M.; van Ratingen, M.R.; Wismans, J.S.H.M.; Cesari, D.

    1998-01-01

    The objective of this study is to evaluate the frontal head-neck performance of the THOR neck with respect to the human frontal head-neck performance and the Hybrid-III frontal head-neck performance. For this purpose, tests were carried out with an isolated THOR and Hybrid-III head-neck system on a

  8. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the seismic module of the CARES system (computer analysis for rapid evaluation of structures). This system was developed to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structural in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the seismic module in particular. The development of the seismic modules of the CARES system is based on an approach which incorporates major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities

  9. On the network protocol performance evaluation for large scale communication system of nuclear plant

    International Nuclear Information System (INIS)

    Song, K. S.; Lee, T. H.; Kim, H. R.; Kim, D. H.; Ku, I. S.

    1998-01-01

    Computer technology has been dramatically advanced and it is now natural to apply digital network technology into nuclear plants. Communication architecture for nuclear plant defines the coordination of safety reactor control, balance of plant, subsystem utilities, and plant monitoring functions, and how they are connected and their user interface to guarantee plant performance and guarantee safety requirements. Therefore, to implement a digital network for control and monitoring systems of advanced nuclear plant needs systematic design and evaluation procedures because of responsive and hard real-time process characteristics of nuclear plant. In this paper, we evaluate several digital network protocols in terms of network delay, link failure effects to hard real-time requirements with full scale traffic

  10. Comparative evaluation of maintenance performance using subsurvival functions

    DEFF Research Database (Denmark)

    Paulsen, J.L.; Cooke, R.; Nyman, R.

    1997-01-01

    Subsurvival functions are applied to operational data for the control rod drive systems of Nordic nuclear reactors to evaluate maintenance performance. Competing failure modes are preventive and corrective maintenance. Maintenance indicators are defined and evaluated for 8 plants. (C) 1997 Elsevier...

  11. The prehospital emergency care system in Mexico City: a system's performance evaluation.

    Science.gov (United States)

    Peralta, Luis Mauricio Pinet

    2006-01-01

    Mexico City has one of the highest mortality rates in Mexico, with non-intentional injuries as a leading cause of death among persons 1-44 years of age. Emergency medical services (EMS) in Mexico can achieve high levels of efficiency by offering high quality medical care at a low cost through adequate system design. The objective of this study was to determine whether the prehospital EMS system in Mexico City meets the criteria standards established by the American Ambulance Association Guide for Contracting Emergency Medical Services (AAA Guide) for highly efficient EMS systems. This retrospective, descriptive study, evaluated the structure of Mexico City's EMS system and analyzed EMS response times, clinical capacity, economic efficiency, and customer satisfaction. These results were compared with the AAA guide, according to the soc ial, economic, and political context in Mexico. This paper describes the healthcare system structure in Mexico, followed by a description of the basic structure of EMS in Mexico City, and of each tenet described in the AAA guide. The p aper includesdata obtained from official documents and databases of government agencies, and operative and administrative data from public and private EMS providers. The quality of the data for response times (RT) were insufficient and widely varied among providers, with a minimum RT of 6.79 minutes (min) and a maximum RT of 61 min. Providers did not define RT clearly, and measured it with averages, which can hide potentially poor performance practices. Training institutions are not required to follow a standardized curriculum. Certifications are the responsibility of the individual training centers and have no government regulation. There was no evidence of active medical control involvement in direct patient care, and providers did not report that quality assurance programs were in place. There also are limited career advancement opportunities for EMS personnel. Small economies of scale may not allow

  12. Evaluation of local exhaust ventilation system performance for control of Fe2O3 dust at an iron making unit

    OpenAIRE

    Mahdi Jamshidi Rastani; Farshid Ghorbani Shahna; Abdolrahman Bahrami; Somayeh Hosseini

    2016-01-01

    Introduction: Adherence to the design values and ventilation standards (VS) after installing and also maintaining continuous work of ventilation system with maximum performance throughout its life are amongst the reasons of ventilation systems monitoring. Therefore, the aim of this study was to evaluate performance of local exhaust ventilation system for control of dust by measuring the operating parameters and also to compare it with ventilation standards (VS) and design values. Material...

  13. EVALUATION OF WOOD PERFORMANCE IN BUILDING CONSTRUCTION THROUGH SYSTEM APPROACH

    Directory of Open Access Journals (Sweden)

    Ricardo Pedreschi

    2005-09-01

    Full Text Available Building construction is considered to be the leading market for the wood industry, in developed and developingcountries. The greatest amount of wood produced in Brazil is consumed as firewood and energy, followed by production of celluloseand third as machined wood. The use of wood from planted forests can be increased. This would lead to a better use of naturalresources, and consequently to an increased sustainability of forest activity in many regions of the country. The performance of woodcan be observed from many different insights: symbolic performance, technical performance and economical performance, conductedby the method of systems approach to architecture. Usages of wood related to the performances of the material, with the redefinitionof parameters of use, elaborating a new culture linked to new technologies were outlined. This work diagnosed the usage of wood inbuilding construction based in system analysis. Through an opinion research related to the acceptation of the use of wood we observethe possibilities of utilization according to physical and mechanical proprieties, aesthetics and appearance performance and postoccupation.According to the results obtained related to the culture and knowledge about the use of wood from planted forest, it canconclude that there is not enough knowledge in this area, and it is, therefore, necessary to create an information system forprofessionals and for people in general.

  14. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  15. Evaluation of the dynamic and kinematic performance of the THOR dummy: neck performance

    NARCIS (Netherlands)

    Hoofman, M.; Ratingen, M.R. van; Wismans, J.S.H.M.

    1998-01-01

    The objective of this study is to evaluate the frontal head-neck performance of the THOR neck with respect to the human frontal head-neck performance and the Hybrid-III frontal head-neck performance. For this purpose, tests were carried out with an isolated THOR and Hybrid-III-neck system on a HyGe

  16. Evaluation of the Trade Space Between UAS Maneuver Performance and SAA System Performance Requirements

    Science.gov (United States)

    Jack, Devin P.; Hoffler, Keith D.; Johnson, Sally C.

    2014-01-01

    A need exists to safely integrate Unmanned Aircraft Systems (UAS) into the National Airspace System. Replacing manned aircraft's see-and-avoid capability in the absence of an onboard pilot is one of the key challenges associated with safe integration. Sense-and-avoid (SAA) systems will have to achieve yet-to-be-determined required separation distances for a wide range of encounters. They will also need to account for the maneuver performance of the UAS they are paired with. The work described in this paper is aimed at developing an understanding of the trade space between UAS maneuver performance and SAA system performance requirements. An assessment of current manned and unmanned aircraft performance was used to establish potential UAS performance test matrix bounds. Then, nearterm UAS integration work was used to narrow down the scope. A simulator was developed with sufficient fidelity to assess SAA system performance requirements for a wide range of encounters. The simulator generates closest-point-of-approach (CPA) data from the wide range of UAS performance models maneuvering against a single intruder with various encounter geometries. The simulator is described herein and has both a graphical user interface and batch interface to support detailed analysis of individual UAS encounters and macro analysis of a very large set of UAS and encounter models, respectively. Results from the simulator using approximate performance data from a well-known manned aircraft is presented to provide insight into the problem and as verification and validation of the simulator. Analysis of climb, descent, and level turn maneuvers to avoid a collision is presented. Noting the diversity of backgrounds in the UAS community, a description of the UAS aerodynamic and propulsive design and performance parameters is included. Initial attempts to model the results made it clear that developing maneuver performance groups is required. Discussion of the performance groups developed and how

  17. Performance evaluation of cellular layouts : extension to DRC system contexts

    NARCIS (Netherlands)

    Suresh, NC; Gaalman, GJC

    This study involves a comparison of the performance of functional layouts (FL) and cellular manufacturing (CM) systems in a dual-resource-constrained( DRC) system context. Past studies of FL and CM have been based mostly on single-resource-constrained( SRC) systems. Recent studies have included

  18. Engineered Barrier System performance requirements systems study report. Revision 02

    International Nuclear Information System (INIS)

    Balady, M.A.

    1997-01-01

    This study evaluates the current design concept for the Engineered Barrier System (EBS), in concert with the current understanding of the geologic setting to assess whether enhancements to the required performance of the EBS are necessary. The performance assessment calculations are performed by coupling the EBS with the geologic setting based on the models (some of which were updated for this study) and assumptions used for the 1995 Total System Performance Assessment (TSPA). The need for enhancements is determined by comparing the performance assessment results against the EBS related performance requirements. Subsystem quantitative performance requirements related to the EBS include the requirement to allow no more than 1% of the waste packages (WPs) to fail before 1,000 years after permanent closure of the repository, as well as a requirement to control the release rate of radionuclides from the EBS. The EBS performance enhancements considered included additional engineered components as well as evaluating additional performance available from existing design features but for which no performance credit is currently being taken

  19. Engineered Barrier System performance requirements systems study report. Revision 02

    Energy Technology Data Exchange (ETDEWEB)

    Balady, M.A.

    1997-01-14

    This study evaluates the current design concept for the Engineered Barrier System (EBS), in concert with the current understanding of the geologic setting to assess whether enhancements to the required performance of the EBS are necessary. The performance assessment calculations are performed by coupling the EBS with the geologic setting based on the models (some of which were updated for this study) and assumptions used for the 1995 Total System Performance Assessment (TSPA). The need for enhancements is determined by comparing the performance assessment results against the EBS related performance requirements. Subsystem quantitative performance requirements related to the EBS include the requirement to allow no more than 1% of the waste packages (WPs) to fail before 1,000 years after permanent closure of the repository, as well as a requirement to control the release rate of radionuclides from the EBS. The EBS performance enhancements considered included additional engineered components as well as evaluating additional performance available from existing design features but for which no performance credit is currently being taken.

  20. Performance evaluation of corrosion-affected reinforced concrete ...

    Indian Academy of Sciences (India)

    M B Anoop

    Abstract. A methodology for performance evaluation of reinforced concrete bridge girders in corrosive ... concrete (RC) members of infrastructural systems, espe- ... bility will be useful for making engineering decisions for ...... Water-cement ratio.

  1. Development of a Human Performance Evaluation Support System for Human Factors Validation of MCR MMI Design in APR-1400

    International Nuclear Information System (INIS)

    Ha, Jun Su; Seong, Poong Hyun

    2005-01-01

    As CRT-based display and advanced information technology were applied to advanced reactors such as APR-1400 (Advanced Power Reactor-1400), human operators' tasks became more cognitive works. As a results, Human Factors Engineering (HFE) became more important in designing the MCR (Main Control Room) MMI (Man-Machine Interface) of an advanced reactor. According to the Human Factors Engineering Program Review Model, human factors validation of MCR MMI design should be performed through performance-based tests to determine whether it acceptably supports safe operation of the plant. In order to support the evaluation of the performance, a HUman Performance Evaluation Support System (HUPESS) is in development

  2. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  3. Evaluation of the performance of diagnosis-related groups and similar casemix systems: methodological issues.

    Science.gov (United States)

    Palmer, G; Reid, B

    2001-05-01

    With the increasing recognition and application of casemix for managing and financing healthcare resources, the evaluation of alternative versions of systems such as diagnosis-related groups (DRGs) has been afforded high priority by governments and researchers in many countries. Outside the United States, an important issue has been the perceived need to produce local versions, and to establish whether or not these perform more effectively than the US-based classifications. A discussion of casemix evaluation criteria highlights the large number of measures that may be used, the rationale and assumptions underlying each measure, and the problems in interpreting the results. A review of recent evaluation studies from a number of countries indicates that considerable emphasis has been placed on the predictive validity criterion, as measured by the R2 statistic. However, the interpretation of the findings has been affected greatly by the methods used, especially the treatment and definition of outlier cases. Furthermore, the extent to which other evaluation criteria have been addressed has varied widely. In the absence of minimum evaluation standards, it is not possible to draw clear-cut conclusions about the superiority of one version of a casemix system over another, the need for a local adaptation, or the further development of an existing version. Without the evidence provided by properly designed studies, policy-makers and managers may place undue reliance on subjective judgments and the views of the most influential, but not necessarily best informed, healthcare interest groups.

  4. Performance-based financing as a health system reform: mapping the key dimensions for monitoring and evaluation

    Science.gov (United States)

    2013-01-01

    Background Performance-based financing is increasingly being applied in a variety of contexts, with the expectation that it can improve the performance of health systems. However, while there is a growing literature on implementation issues and effects on outputs, there has been relatively little focus on interactions between PBF and health systems and how these should be studied. This paper aims to contribute to filling that gap by developing a framework for assessing the interactions between PBF and health systems, focusing on low and middle income countries. In doing so, it elaborates a general framework for monitoring and evaluating health system reforms in general. Methods This paper is based on an exploratory literature review and on the work of a group of academics and PBF practitioners. The group developed ideas for the monitoring and evaluation framework through exchange of emails and working documents. Ideas were further refined through discussion at the Health Systems Research symposium in Beijing in October 2012, through comments from members of the online PBF Community of Practice and Beijing participants, and through discussion with PBF experts in Bergen in June 2013. Results The paper starts with a discussion of definitions, to clarify the core concept of PBF and how the different terms are used. It then develops a framework for monitoring its interactions with the health system, structured around five domains of context, the development process, design, implementation and effects. Some of the key questions for monitoring and evaluation are highlighted, and a systematic approach to monitoring effects proposed, structured according to the health system pillars, but also according to inputs, processes and outputs. Conclusions The paper lays out a broad framework within which indicators can be prioritised for monitoring and evaluation of PBF or other health system reforms. It highlights the dynamic linkages between the domains and the different pillars

  5. Performance-based financing as a health system reform: mapping the key dimensions for monitoring and evaluation.

    Science.gov (United States)

    Witter, Sophie; Toonen, Jurrien; Meessen, Bruno; Kagubare, Jean; Fritsche, György; Vaughan, Kelsey

    2013-09-29

    Performance-based financing is increasingly being applied in a variety of contexts, with the expectation that it can improve the performance of health systems. However, while there is a growing literature on implementation issues and effects on outputs, there has been relatively little focus on interactions between PBF and health systems and how these should be studied. This paper aims to contribute to filling that gap by developing a framework for assessing the interactions between PBF and health systems, focusing on low and middle income countries. In doing so, it elaborates a general framework for monitoring and evaluating health system reforms in general. This paper is based on an exploratory literature review and on the work of a group of academics and PBF practitioners. The group developed ideas for the monitoring and evaluation framework through exchange of emails and working documents. Ideas were further refined through discussion at the Health Systems Research symposium in Beijing in October 2012, through comments from members of the online PBF Community of Practice and Beijing participants, and through discussion with PBF experts in Bergen in June 2013. The paper starts with a discussion of definitions, to clarify the core concept of PBF and how the different terms are used. It then develops a framework for monitoring its interactions with the health system, structured around five domains of context, the development process, design, implementation and effects. Some of the key questions for monitoring and evaluation are highlighted, and a systematic approach to monitoring effects proposed, structured according to the health system pillars, but also according to inputs, processes and outputs. The paper lays out a broad framework within which indicators can be prioritised for monitoring and evaluation of PBF or other health system reforms. It highlights the dynamic linkages between the domains and the different pillars. All of these are also framed within

  6. Solar-energy-system performance evaluation update: San Anselmo School, San Jose, California, April 1982-June 1982

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, P.W.

    1982-01-01

    The solar collector array at the San Anselmo School is located on the roof of the structure, and consists of 3740 square feet of General Electric evacuated tube solar collectors, Model TC-100. Performance of the array during the three-month period was very similar to the overall performance during the previous reporting periods. During the three-month period from April 1982 through June 1982, the solar system at the San Anselmo School performed below expectations despite continued attempts to alleviate several long-standing system problems. Space heating performance appears to be meeting design goals; however, this load was trivial during the three-month period. The retrofitted solar system was designed to provide 70% of the space heating load and 72% of the space cooling load at this 34,000-square-foot brick structure. In all of the previous months of evaluation, the design values of 70% and above have not been achieved for the system as a whole, although one subsystem did achieve high solar contributions during periods of lower building loads, specifically the space heating subsystem. Solar contribution during the three-month period of April 1982 through June 1982 averaged 19% of the total load of 117.4 million Btu, and was, at best, equal to previous performance. Space heating loads were small, and the space cooling load was relatively high over the test period. The solar savings ratio was 14%. The system performance factor is a measure of the equivalent fossil fuel consumption at the site (with operating energy multiplied by 3.33 times to simulate fossil fuel use at the power plant) relative to the actual load, and was 0.15. This value is 0.03 points less than the previous year's value of 0.18. Solar System Coefficient of Performance (COP) increased to 11.0 vs. the previous year's value of 7.6. Apparently, the efficiency of energy transfer in the system has improved, although performance was not really any better.

  7. The Development of a Scientific Evaluation System of Force-on-Force (FOF) Exercise for Performance-based Regulation in Nuclear Security

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Moonsung; Jung, Myungtak [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2015-05-15

    A terrorist attack or sabotage at a nuclear facility could lead result in a great amount of loss of life and social chaos, in addition to serious radiological damage. As threats have been evolved more intelligent, divergent, advanced, the international societies including IAEA encourage for all member states to establish the performance-based regulation using Forceon- Force (FOF) exercise, computer simulation. Consequently, the performance evaluation for physical protection at nuclear facilities should focus on properly reacting to threat scenarios. Physical protection should also include detecting, blocking, delaying, interrupting including the human and technical factors the adversary having malicious intention of the realistic main threat element before he accomplishes the goal based on Design Basis Threat (DBT). After the completion of the FOF evaluation system, KINAC will evaluate, and later strengthen its overall security program in response to changes in the threat environment, technological advancements, and lessons learned. As a result, substantial improvements to a nuclear facility security can be predicted. These improvements will focus on a plant security force, physical barriers, intrusion detection systems, surveillance systems, and access controls. Through the building a Force-on-Force scientific evaluation system, KINAC will establish an efficient physical protection implementation system for nuclear energy facilities.

  8. The Development of a Scientific Evaluation System of Force-on-Force (FOF) Exercise for Performance-based Regulation in Nuclear Security

    International Nuclear Information System (INIS)

    Koh, Moonsung; Jung, Myungtak

    2015-01-01

    A terrorist attack or sabotage at a nuclear facility could lead result in a great amount of loss of life and social chaos, in addition to serious radiological damage. As threats have been evolved more intelligent, divergent, advanced, the international societies including IAEA encourage for all member states to establish the performance-based regulation using Forceon- Force (FOF) exercise, computer simulation. Consequently, the performance evaluation for physical protection at nuclear facilities should focus on properly reacting to threat scenarios. Physical protection should also include detecting, blocking, delaying, interrupting including the human and technical factors the adversary having malicious intention of the realistic main threat element before he accomplishes the goal based on Design Basis Threat (DBT). After the completion of the FOF evaluation system, KINAC will evaluate, and later strengthen its overall security program in response to changes in the threat environment, technological advancements, and lessons learned. As a result, substantial improvements to a nuclear facility security can be predicted. These improvements will focus on a plant security force, physical barriers, intrusion detection systems, surveillance systems, and access controls. Through the building a Force-on-Force scientific evaluation system, KINAC will establish an efficient physical protection implementation system for nuclear energy facilities

  9. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  10. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  11. Human performance modeling for system of systems analytics: combat performance-shaping factors.

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, Craig R.; Miller, Dwight Peter

    2006-01-01

    The US military has identified Human Performance Modeling (HPM) as a significant requirement and challenge of future systems modeling and analysis initiatives. To support this goal, Sandia National Laboratories (SNL) has undertaken a program of HPM as an integral augmentation to its system-of-system (SoS) analytics capabilities. The previous effort, reported in SAND2005-6569, evaluated the effects of soldier cognitive fatigue on SoS performance. The current effort began with a very broad survey of any performance-shaping factors (PSFs) that also might affect soldiers performance in combat situations. The work included consideration of three different approaches to cognition modeling and how appropriate they would be for application to SoS analytics. This bulk of this report categorizes 47 PSFs into three groups (internal, external, and task-related) and provides brief descriptions of how each affects combat performance, according to the literature. The PSFs were then assembled into a matrix with 22 representative military tasks and assigned one of four levels of estimated negative impact on task performance, based on the literature. Blank versions of the matrix were then sent to two ex-military subject-matter experts to be filled out based on their personal experiences. Data analysis was performed to identify the consensus most influential PSFs. Results indicate that combat-related injury, cognitive fatigue, inadequate training, physical fatigue, thirst, stress, poor perceptual processing, and presence of chemical agents are among the PSFs with the most negative impact on combat performance.

  12. Performance evaluation of one coat systems for new steel bridges.

    Science.gov (United States)

    2011-06-01

    In an effort to address cost issues associated with shop application of conventional three-coat systems, the Federal : Highway Administration completed a study to investigate the performance of eight one-coat systems and two control : coatings for co...

  13. Performance estimates for personnel access control systems

    International Nuclear Information System (INIS)

    Bradley, R.G.

    1980-10-01

    Current performance estimates for personnel access control systems use estimates of Type I and Type II verification errors. A system performance equation which addresses normal operation, the insider, and outside adversary attack is developed. Examination of this equation reveals the inadequacy of classical Type I and II error evaluations which require detailed knowledge of the adversary threat scenario for each specific installation. Consequently, new performance measures which are consistent with the performance equation and independent of the threat are developed as an aid in selecting personnel access control systems

  14. [Evaluation of the performance of the logistics management system of malaria control resources in the Littoral Department, Benin, in 2017].

    Science.gov (United States)

    Ouro-Koura, Abdou-Rahim; Sopoh, Emmanuel Ghislain; Sossa, Jerôme Charles; Glèlè-Ahanhanzo, Yolaine; Agueh, Victoire; Ouendo, Edgard-Marius; Ouedraogo, Laurent

    2018-01-01

    This study aimed to evaluate the performance of the logistics management system (LMS) of malaria control (MC) resources in the Littoral Department, Benin, in 2017. In June 2017, we conducted a cross-sectional evaluative study focusing on the structures for the storage and the disposal of MC resources as well as on staff involved in their management. The performance of the the logistics management system was evaluated on the basis of the observed compliance of the components and sub-components of the "Structure", the "Process" and the "Results" with the norms and standards defined by the Ministry of Health. A total of 36 structures were investigated and secondary target was surveyed. It followed that 52,78% of the structures for the storage and the disposal of MC resources met the requirements for resources storage while only 33.33% of MC resources management staff were trained in logistics management. The performance of the logistics management system of MC resources was inadequate (compliance 59,13 % compared to the expected score). The structure, as well as the process were non-compliant with the standards ( 60,20% and 73.22% compared to the expected score respectively), leading to negative results (41.53% compared to the expected score). The most inadequate sub-component was the logistics management information system (LMIS). This study highlights the role of LMS for better performance of MC resources management. Particular attention should be given to this component.

  15. Uncertainty analysis of daily potable water demand on the performance evaluation of rainwater harvesting systems in residential buildings.

    Science.gov (United States)

    Silva, Arthur Santos; Ghisi, Enedir

    2016-09-15

    The objective of this paper is to perform a sensitivity analysis of design variables and an uncertainty analysis of daily potable water demand to evaluate the performance of rainwater harvesting systems in residential buildings. Eight cities in Brazil with different rainfall patterns were analysed. A numeric experiment was performed by means of computer simulation of rainwater harvesting. A sensitivity analysis was performed using variance-based indices for identifying the most important design parameters for rainwater harvesting systems when assessing the potential for potable water savings and underground tank capacity sizing. The uncertainty analysis was performed for different scenarios of potable water demand with stochastic variations in a normal distribution with different coefficients of variation throughout the simulated period. The results have shown that different design variables, such as potable water demand, number of occupants, rainwater demand, and roof area are important for obtaining the ideal underground tank capacity and estimating the potential for potable water savings. The stochastic variations on the potable water demand caused amplitudes of up to 4.8% on the potential for potable water savings and 9.4% on the ideal underground tank capacity. Average amplitudes were quite low for all cities. However, some combinations of parameters resulted in large amplitude of uncertainty and difference from uniform distribution for tank capacities and potential for potable water savings. Stochastic potable water demand generated low uncertainties in the performance evaluation of rainwater harvesting systems; therefore, uniform distribution could be used in computer simulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

    Science.gov (United States)

    Mathur, A. K.; Pederson, S.

    1982-01-01

    The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

  17. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

    Science.gov (United States)

    Erlandsson, Kjell; Kacperski, Krzysztof; van Gramberg, Dean; Hutton, Brian F.

    2009-05-01

    D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a β-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s-1 MBq-1 per head (99mTc, 10 cm) (CS: 72 s-1 MBq-1), and the tomographic sensitivity in the heart region was in the range 647-1107 s-1 MBq-1 (CS: 141 s-1 MBq-1). The count rate increased linearly with increasing activity up to 1.44 M s-1. The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

  18. Economic framework for information system evaluation

    International Nuclear Information System (INIS)

    King, D.W.; Roderer, N.K.

    1979-01-01

    In the evaluation of complex information systems, it is useful to work within a generalized economic framework. This framework is based on consideration of four evaluation levels, including those associated with the overall system, system functions, products and services, and activities. Measures of cost and output can be defined at each level, with output measures related to volume of activity, performance, effectiveness, and benefit. The description of this framework includes definitions of the terminology used. Examples of the application of the framework to specific information system evaluations are also given. 4 figures

  19. Evaluation of Performance Measurement Instruments on Their Use for Food Quality Systems

    NARCIS (Netherlands)

    Spiegel, van der M.; Luning, P.A.; Ziggers, G.W.; Jongen, W.M.F.

    2004-01-01

    Due to regular challenges of food safety, consumers put high demands on the performance of food quality systems. To deal with these requirements, food manufacturers need effective quality management. Performance of food quality systems can be partly realized by quality assurance systems, such as

  20. Evaluation of Performance Measurement Instruments on their use for Food Quality Systems

    NARCIS (Netherlands)

    Spiegel, M. van der; Luning, P.A.; Ziggers, G.W.; Jongen, W.M.F.

    2005-01-01

    Due to regular challenges of food safety, consumers put high demands on the performance of food quality systems. To deal with these requirements, food manufacturers need effective quality management. Performance of food quality systems can be partly realized by quality assurance systems, such as

  1. Phase II test plan for the evaluation of the performance of container filling systems

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The PHMC will provide tank wastes for final treatment by BNFL from Hanford's waste tanks. Concerns about the ability for ''grab'' sampling to provide large volumes of representative waste samples has led to the development of a nested, fixed-depth sampling system. Preferred concepts for filling sample containers that meet RCRA organic sample criteria were identified by a PHMC Decision Board. These systems will replace the needle based sampling ''T'' that is currently on the sampling system. This test plan document identifies cold tests with simulants that will demonstrate the preferred bottle filling concepts abilities to provide representative waste samples and will meet RCRA criteria. Additional tests are identified that evaluate the potential for cross-contamination between samples and the ability for the system to decontaminate surfaces which have contacted tank wastes. These tests will be performed with kaolidwater and sand/water slurry simulants in the test rig that was used by AEAT to complete Phase 1 tests in FY 1999

  2. Performance Health Monitoring of Large-Scale Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamony, Ram [IBM Research, Austin, TX (United States)

    2014-11-20

    This report details the progress made on the ASCR funded project Performance Health Monitoring for Large Scale Systems. A large-­scale application may not achieve its full performance potential due to degraded performance of even a single subsystem. Detecting performance faults, isolating them, and taking remedial action is critical for the scale of systems on the horizon. PHM aims to develop techniques and tools that can be used to identify and mitigate such performance problems. We accomplish this through two main aspects. The PHM framework encompasses diagnostics, system monitoring, fault isolation, and performance evaluation capabilities that indicates when a performance fault has been detected, either due to an anomaly present in the system itself or due to contention for shared resources between concurrently executing jobs. Software components called the PHM Control system then build upon the capabilities provided by the PHM framework to mitigate degradation caused by performance problems.

  3. Research and performance evaluation on an HA integrated acid system for sandstone acidizing

    Directory of Open Access Journals (Sweden)

    Liqiang Zhao

    2018-03-01

    Full Text Available When the conventional sandstone acidizing technologies are adopted, many slugs are needed in the injection of prepad fluid, treatment fluid and postpad fluid, and consequently the production and operation suffers inconveniences and difficulties. In view of this, a kind of HA integrated acid system which is mainly composed of organic polybasic acids (HA+HCl + HF and an efficient organic solvent was developed in this paper based on the idea of integrated acid replacing ''multiple steps'' and high efficiency and intensification. Via this HA integrated acid system, the complicated blockage in sandstone reservoirs can be removed effectively. Then, experiments were carried out on this system to evaluate its performance in terms of its retardance, organic blockage dissolution, chelating and precipitation inhibition. It is indicated that this new system can not only realize the acidizing of conventional integrated acid, but also present a good retarding performance by controlling H+ multi-stage ionization step by step and by forming silica acid-aluminum phosphonate film on the surface of clay minerals; that via this new HA integrated acid system, the organic blockage can be removed efficiently; and that it is wider in pH solution range than conventional APCs (aminopolycarboxyliates chelants, stronger in chelating capacity of Ca2+, Mg2+ and Fe3+ than conventional chelants (e.g. EDTA, NTA and DTPA, and better in precipitation inhibition on metal fluoride, fluosilicic acid alkali metal, fluoaluminic acid alkali metal and hydroxide than multi-hydrogen acid, fluoboric acid and mud acid systems. These research results provide a technical support for the plugging removal in high-temperature deep oil and gas reservoirs. Keywords: Organic polybasic acid, Integrated acid, Retardance, Chelating, Precipitation, Acidizing, Sandstone, Reservoir

  4. Features principles and purposes of teacher performance evaluation.

    Directory of Open Access Journals (Sweden)

    Esnares José Maussa Díaz

    2015-03-01

    Full Text Available Teacher evaluation represents a nodal aspect for improving of system education. Any evaluation has a previously predefined purpose and is essentially a valorative act, where the principles applied are indicators of the degree of responsibility which is performed and the visión that society gives to the education. This paper analyzes how the purposes are fulfilled, principles and characteristics of the performance evaluation of teachers in connection with the practice of respect for the guiding principles of assessment practice teaching; just like existing rating on indicators of professional and personal development achieved by teachers as a result of the evaluative practices in the context of the pursuit of improving of quality of education. 

  5. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  6. Upgrading Supply Chain Management Systems to Improve Availability of Medicines in Tanzania: Evaluation of Performance and Cost Effects.

    Science.gov (United States)

    Mwencha, Marasi; Rosen, James E; Spisak, Cary; Watson, Noel; Kisoka, Noela; Mberesero, Happiness

    2017-09-27

    To address challenges in public health supply chain performance, Tanzania invested in a national logistics management unit (LMU) and a national electronic logistics management information system (eLMIS). This evaluation examined the impact of those 2 key management upgrades approximately 1 year after they were introduced. We used a nonexperimental pre-post study design to compare the previous system with the upgraded management system. We collected baseline data from August to November 2013. We conducted round 1 of post-implementation data collection during April and May 2015, about 1 year after implementation of the upgrades. We evaluated key indicators of data use and reporting; supply chain management practices such as storage and supervision; supply chain performance including stock-out and expiry rates; and supply chain cost and savings. We analyzed the data using a range of techniques including statistical testing of baseline and round-1 results, and cost, cost-effectiveness, and return on investment analysis. The upgrades were associated with improvements in data use, accessibility, visibility, and transparency; planning, control, and monitoring; support for quantification; stock-out rates; stock-out duration; commodity expiry; and forecast error. The upgraded system was more costly, but it was also more efficient, particularly when adjusting for the performance improvements. The upgrades also generated substantial savings that defrayed some, but not all, of the investment costs. Upgrades to Tanzania's supply chain management systems created multiple and complex pathways to impact. One year after implementation, the LMU and eLMIS brought about performance improvements through better data use and through improvements in some, but not all, management practices. Furthermore, the upgrades-while not inexpensive-contributed to greater system efficiency and modest savings. © Mwencha et al.

  7. Evaluation of a flat-panel detector system

    International Nuclear Information System (INIS)

    Sato, Masami; Eguchi, Yoichi; Yamada, Kinichi; Kaga, Yuji; Endo, Yutaka; Yamazaki, Tatsuya

    2001-01-01

    We evaluated the imaging performance of a flat-panel detector digital radiography system (CXDI-11 X-ray Digital Camera, Canon Inc.) and a computed radiography system (FCR9000C-HQ, Fuji Film). The characteristics of the two detectors and of the overall systems were compared. This included evaluation and comparison of the fundamental physical characteristics, including x-ray response curve, modulation transfer function (MTF), Wiener spectra, noise-equivalent quanta, and x-ray tube voltage-dependent detector response. Overall system performance was evaluated using receiver operating characteristic (ROC) analysis. The results of the study showed that the dynamic range of the CXDI-11 measured relative to the input x-ray flux was 10 3 , similar to that of the FCR9000C-HQ. Both systems showed similar final MTFs, although the pre-sampling MTF of the CXDI-11 was better than that of the FCR9000C-HQ. Noise analysis, based on noise-equivalent quanta and Wiener spectra, showed that for normal exposure conditions the CXDI-11 had superior performance. With both systems, x-ray response (system output/incident x-ray exposure) increased with increasing x-ray tube voltage. ROC analysis indicated that the CXDI-11 was superior in overall performance. (author)

  8. Performance Evaluation of New Joint EDF-RM Scheduling Algorithm for Real Time Distributed System

    Directory of Open Access Journals (Sweden)

    Rashmi Sharma

    2014-01-01

    Full Text Available In Real Time System, the achievement of deadline is the main target of every scheduling algorithm. Earliest Deadline First (EDF, Rate Monotonic (RM, and least Laxity First are some renowned algorithms that work well in their own context. As we know, there is a very common problem Domino's effect in EDF that is generated due to overloading condition (EDF is not working well in overloading situation. Similarly, performance of RM is degraded in underloading condition. We can say that both algorithms are complements of each other. Deadline missing in both events happens because of their utilization bounding strategy. Therefore, in this paper we are proposing a new scheduling algorithm that carries through the drawback of both existing algorithms. Joint EDF-RM scheduling algorithm is implemented in global scheduler that permits task migration mechanism in between processors in the system. In order to check the improved behavior of proposed algorithm we perform simulation. Results are achieved and evaluated in terms of Success Ratio (SR, Average CPU Utilization (ECU, Failure Ratio (FR, and Maximum Tardiness parameters. In the end, the results are compared with the existing (EDF, RM, and D_R_EDF algorithms. It has been shown that the proposed algorithm performs better during overloading condition as well in underloading condition.

  9. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  10. Performance evaluation of hospitals that provide care in the public health system, Brazil.

    Science.gov (United States)

    Ramos, Marcelo Cristiano de Azevedo; da Cruz, Lucila Pedroso; Kishima, Vanessa Chaer; Pollara, Wilson Modesto; de Lira, Antônio Carlos Onofre; Couttolenc, Bernard François

    2015-01-01

    OBJECTIVE To analyze if size, administrative level, legal status, type of unit and educational activity influence the hospital network performance in providing services to the Brazilian Unified Health System. METHODS This cross-sectional study evaluated data from the Hospital Information System and the Cadastro Nacional de Estabelecimentos de Saúde (National Registry of Health Facilities), 2012, in Sao Paulo, Southeastern Brazil. We calculated performance indicators, such as: the ratio of hospital employees per bed; mean amount paid for admission; bed occupancy rate; average length of stay; bed turnover index and hospital mortality rate. Data were expressed as mean and standard deviation. The groups were compared using analysis of variance (ANOVA) and Bonferroni correction. RESULTS The hospital occupancy rate in small hospitals was lower than in medium, big and special-sized hospitals. Higher hospital occupancy rate and bed turnover index were observed in hospitals that include education in their activities. The hospital mortality rate was lower in specialized hospitals compared to general ones, despite their higher proportion of highly complex admissions. We found no differences between hospitals in the direct and indirect administration for most of the indicators analyzed. CONCLUSIONS The study indicated the importance of the scale effect on efficiency, and larger hospitals had a higher performance. Hospitals that include education in their activities had a higher operating performance, albeit with associated importance of using human resources and highly complex structures. Specialized hospitals had a significantly lower rate of mortality than general hospitals, indicating the positive effect of the volume of procedures and technology used on clinical outcomes. The analysis related to the administrative level and legal status did not show any significant performance differences between the categories of public hospitals.

  11. Performance evaluation of hospitals that provide care in the public health system, Brazil

    Directory of Open Access Journals (Sweden)

    Marcelo Cristiano de Azevedo Ramos

    2015-01-01

    Full Text Available OBJECTIVE To analyze if size, administrative level, legal status, type of unit and educational activity influence the hospital network performance in providing services to the Brazilian Unified Health System.METHODS This cross-sectional study evaluated data from the Hospital Information System and the Cadastro Nacional de Estabelecimentos de Saúde (National Registry of Health Facilities, 2012, in Sao Paulo, Southeastern Brazil. We calculated performance indicators, such as: the ratio of hospital employees per bed; mean amount paid for admission; bed occupancy rate; average length of stay; bed turnover index and hospital mortality rate. Data were expressed as mean and standard deviation. The groups were compared using analysis of variance (ANOVA and Bonferroni correction.RESULTS The hospital occupancy rate in small hospitals was lower than in medium, big and special-sized hospitals. Higher hospital occupancy rate and bed turnover index were observed in hospitals that include education in their activities. The hospital mortality rate was lower in specialized hospitals compared to general ones, despite their higher proportion of highly complex admissions. We found no differences between hospitals in the direct and indirect administration for most of the indicators analyzed.CONCLUSIONS The study indicated the importance of the scale effect on efficiency, and larger hospitals had a higher performance. Hospitals that include education in their activities had a higher operating performance, albeit with associated importance of using human resources and highly complex structures. Specialized hospitals had a significantly lower rate of mortality than general hospitals, indicating the positive effect of the volume of procedures and technology used on clinical outcomes. The analysis related to the administrative level and legal status did not show any significant performance differences between the categories of public hospitals.

  12. Document Level Assessment of Document Retrieval Systems in a Pairwise System Evaluation

    Science.gov (United States)

    Rajagopal, Prabha; Ravana, Sri Devi

    2017-01-01

    Introduction: The use of averaged topic-level scores can result in the loss of valuable data and can cause misinterpretation of the effectiveness of system performance. This study aims to use the scores of each document to evaluate document retrieval systems in a pairwise system evaluation. Method: The chosen evaluation metrics are document-level…

  13. Evaluating the Impact of Communication Network Performance on Supervisory Supermarket Control

    DEFF Research Database (Denmark)

    Madsen, Jacob Theilgaard; Minko, Tomasz; Madsen, Tatiana Kozlova

    2017-01-01

    This paper addresses the evaluation of the impact of non-ideal communication networks on system performance of hierarchical control systems. It develops a stepwise evaluation approach that is applied to the example scenario of a supervisory controller for supermarket temperature control, addressing...... of communication network performance on the supermarket refrigeration control and resulting energy costs using simulation models. The results show that the controller is resilient to downstream information delays, however upstream delays or up- and downstream information loss can cause significant performance...

  14. Performance evaluation of a tri-generation system with simulation and experiment

    International Nuclear Information System (INIS)

    Ge, Y.T.; Tassou, S.A.; Chaer, I.; Suguartha, N.

    2009-01-01

    A test rig for a tri-generation system was set up in the laboratory to investigate the system performance and application feasibility. The rig was composed of three modules, a power component containing a microturbine, a refrigeration unit consisting of an absorption chiller with gas pipe connection, and a supermarket section containing a display cabinet. This system was supposed to be effectively applied into a supermarket energy control system where cooling, heating and electricity power are simultaneously required and subsequently, valuable test results have been produced. In the mean time, a simulation model for the particular tri-generation system has been established by integrating the component models of the system in accordance with the components' actual flow paths and energy streams. These component models, which include a compressor, recuperator, combustion chamber, gas turbine, electric generator, gas pipes, generator (desorber), rectifier, absorbers, condenser and evaporator etc., were developed based upon the balance of heat and mass. The calculations of heat transfer and phase equilibrium were included in the component models and chemical reaction balances were considered in the model of the combustion chamber. The system model has been validated with the test results and has consequently been used to predict the system performance at different operating and design conditions, such as varied ambient temperature, fuel flow rate and pressure ratio etc. The ultimate results of the performance analysis formulated by the system model can contribute significantly to the optimal component and system designs in various practical applications.

  15. Measurement-Based Performance Evaluation of Advanced MIMO Transceiver Designs

    Directory of Open Access Journals (Sweden)

    Schneider Christian

    2005-01-01

    Full Text Available This paper describes the methodology and the results of performance investigations on a multiple-input multiple-output (MIMO transceiver scheme for frequency-selective radio channels. The method relies on offline simulations and employs real-time MIMO channel sounder measurement data to ensure a realistic channel modeling. Thus it can be classified in between the performance evaluation using some predefined channel models and the evaluation of a prototype hardware in field experiments. New aspects for the simulation setup are discussed, which are frequently ignored when using simpler model-based evaluations. Example simulations are provided for an iterative ("turbo" MIMO equalizer concept. The dependency of the achievable bit error rate performance on the propagation characteristics and on the variation in some system design parameters is shown, whereas the antenna constellation is of particular concern for MIMO systems. Although in many of the considered constellations turbo MIMO equalization appears feasible in real field scenarios, there exist cases with poor performance as well, indicating that in practical applications link adaptation of the transmitter and receiver processing to the environment is necessary.

  16. IBM PC/IX operating system evaluation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  17. Health-educator performance evaluation for quality teaching ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the efficacy of health educator performance evaluation procedures using the Integrated Quality Management System. This quantitative study used questionnaires to collect data from three hundred and thirty eight respondents selected through a convenient sampling procedure.

  18. A mathematical modeling framework to evaluate the performance of single diode and double diode based SPV systems

    Directory of Open Access Journals (Sweden)

    Sangram Bana

    2016-11-01

    Full Text Available In order to predict the performance of a PV system, a reliable and accurate simulation design of PV systems before being installed is a necessity. The present study concerns the development of single and double diode model of solar PV system and ensures the best suited model under specific environmental condition for accurate performance prediction. The information provided in the manufacturers’ data sheet is not sufficient for developing a Simulink based single and double diode models of PV module. These parameters are crucial to predict accurate performance of a PV module. These parameters of the proposed solar PV models have been calculated using an efficient iterative technique. This paper compares the simulation results of both the models with manufacturer’s data sheet to investigate the accuracy and validity. A MATLAB/Simulink based comparative performance analysis of these models under inconsistent atmospheric conditions and the effect of variations in model parameters has been carried out. Despite the simplicity, these models are highly sensitive and respond to a slight variation in temperature and insolation. It is observed that double diode PV model is more accurate under low intensity insolation or shading condition. The performance evaluation of the models under present study will be helpful to understand the I-V curves, which will enable us in predicting the solar PV system power production under variable input conditions.

  19. ASUPT Automated Objective Performance Measurement System.

    Science.gov (United States)

    Waag, Wayne L.; And Others

    To realize its full research potential, a need exists for the development of an automated objective pilot performance evaluation system for use in the Advanced Simulation in Undergraduate Pilot Training (ASUPT) facility. The present report documents the approach taken for the development of performance measures and also presents data collected…

  20. Novel approaches to improve iris recognition system performance based on local quality evaluation and feature fusion.

    Science.gov (United States)

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; Chen, Huiling; He, Fei; Pang, Yutong

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system.

  1. System Function Evaluation due to Hardware Failure of NSSS Control Systems in the APR1400

    International Nuclear Information System (INIS)

    Kim, Juyoung; Ahn, Myunghoon; Kim, Woogoon; Yim, Hyeongsoon

    2016-01-01

    As the performance and failure modes of the control systems may affect the plant response to accidents or disturbances, an evaluation is done to identify potential control system failure modes resulting from single hardware failures. These failure modes are for use in the analytical evaluations that will be performed to assess the plant responses to various disturbances from the viewpoint of postulated system malfunctions. Failure modes that fall into any of the above categories will affect the performance of the control system and should be considered in the analytical evaluation of the NSSS responses to disturbances. An evaluation was performed to identify the failure modes of the NSSS Control Systems, caused by a hardware component, a common sensing device, and a common power supply. The multiple failure modes across the NSSS control Systems are limited by the improved design features, redundancy within each systems, and segmentation between systems. Also, the effects from the failure modes are expected to be acceptably terminated by the Plant Protection System. The failure modes derived through this evaluation will be further considered in the analytical evaluation of the NSSS responses to disturbances in order to identify the single failures which could create the most adverse conditions during a given transient

  2. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    Science.gov (United States)

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. System Life Cycle Evaluation(SM) (SLiCE): harmonizing water treatment systems with implementers' needs.

    Science.gov (United States)

    Goodman, Joseph; Caravati, Kevin; Foote, Andrew; Nelson, Molly; Woods, Emily

    2013-06-01

    One of the methods proposed to improve access to clean drinking water is the mobile packaged water treatment system (MPWTS). The lack of published system performance comparisons combined with the diversity of technology available and intended operating conditions make it difficult for stakeholders to choose the system best suited for their application. MPWTS are often deployed in emergency situations, making selection of the appropriate system crucial to avoiding wasted resources and loss of life. Measurable critical-to-quality characteristics (CTQs) and a system selection tool for MPWTS were developed by utilizing relevant literature, including field studies, and implementing and comparing seven different MPWTS. The proposed System Life Cycle Evaluation (SLiCE) method uses these CTQs to evaluate the diversity in system performance and harmonize relevant performance with stakeholder preference via a selection tool. Agencies and field workers can use SLiCE results to inform and drive decision-making. The evaluation and selection tool also serves as a catalyst for communicating system performance, common design flaws, and stakeholder needs to system manufacturers. The SLiCE framework can be adopted into other emerging system technologies to communicate system performance over the life cycle of use.

  4. Solar energy system performance evaluation: Seasonal report for IBM system 1A, Huntsville, Alabama

    Science.gov (United States)

    1980-01-01

    The operational and thermal performance of the solar energy system, Sims Prototype System 1A, is described. The system was designed by IBM to provide 50 to 60 percent of the space heating and domestic hot water preheating load to a 2,000 square foot floor space single family residence in the Huntsville area. The load design temperature inside the building was to be maintained at 70 degrees fahrenheit with auxiliary energy for heating supplied by an electric heat pump assisted by an electric resistance strip heater. In general the disappointing operation of this system is attributed to the manner in which it was used. The system was designed for residential application and used to satisfy the demands of an office environment. The differences were: (1) inside temperature was not maintained at 70 F as expected; and (2) hot water usage was much lower than expected. The conclusion is that the solar energy system must be designed for the type of application in which it is used. Misapplication usually will have an adverse affect on system performance.

  5. Selecting a change and evaluating its impact on the performance of a complex adaptive health care delivery system

    Directory of Open Access Journals (Sweden)

    Malaz A Boustani

    2010-05-01

    Full Text Available Malaz A Boustani1,2,3,4, Stephanie Munger1,2, Rajesh Gulati3,4, Mickey Vogel4, Robin A Beck3,4, Christopher M Callahan1,2,3,41Indiana University Center for Aging Research, 2Regenstrief Institute Inc., 3Indiana University School of Medicine, Department of Medicine, Division of General Internal Medicine and Geriatrics, 4Indiana University Medical Group-Primary Care; Indianapolis, IN USAAbstract: Complexity science suggests that our current health care delivery system acts as a complex adaptive system (CAS. Such systems represent a dynamic and flexible network of individuals who can coevolve with their ever changing environment. The CAS performance fluctuates and its members’ interactions continuously change over time in response to the stress generated by its surrounding environment. This paper will review the challenges of intervening and introducing a planned change into a complex adaptive health care delivery system. We explore the role of the “reflective adaptive process” in developing delivery interventions and suggest different evaluation methodologies to study the impact of such interventions on the performance of the entire system. We finally describe the implementation of a new program, the Aging Brain Care Medical Home as a case study of our proposed evaluation process.Keywords: complexity, aging brain, implementation, complex adaptive system, sustained change, care delivery

  6. Probabilistic performance assessments for evaluations of the Yucca Mountain site

    International Nuclear Information System (INIS)

    Rickertsen, L.D.; Noronha, C.J.

    1992-01-01

    Site suitability evaluations are conducted to determine if a repository system at a particular site will be able to meet the performance objectives for that system. Early evaluations to determine if the Yucca Mountain site is suitable for repository development have been made in the face of large uncertainties in site features and conditions. Because of these large uncertainties, the evaluations of the site have been qualitative in nature, focusing on the presence or absence of particular features or conditions thought to be important to performance, rather than on results of quantitative performance assessments. Such a qualitative approach was used in the recently completed evaluation of the Yucca Mountain site, the Early Site-Suitability Evaluation (ESSE). In spite of the qualitative approach, the ESSE was able to conclude that no disqualifying conditions are likely to be present at the site and that all of the geologic conditions that would qualify the site are likely to be met. At the same time, because of the qualitative nature of the approach used in the ESSE, the precise importance of the identified issues relative to performance could not be determined. Likewise, the importance of the issues relative to one another could not be evaluated, and, other than broad recommendations, specific priorities for future testing could not be set. The authors have conducted quantitative performance assessments for the Yucca Mountain site to address these issues

  7. Performance evaluation of a tri-generation system with simulation and experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Y.T.; Tassou, S.A.; Suguartha, N. [Mechanical Engineering, School of Engineering and Design, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom); Chaer, I. [Faculty of Engineering, Science and the Built Environment, London South Bank University (T617), Borough Road, London SE1 0AA (United Kingdom)

    2009-11-15

    A test rig for a tri-generation system was set up in the laboratory to investigate the system performance and application feasibility. The rig was composed of three modules, a power component containing a microturbine, a refrigeration unit consisting of an absorption chiller with gas pipe connection, and a supermarket section containing a display cabinet. This system was supposed to be effectively applied into a supermarket energy control system where cooling, heating and electricity power are simultaneously required and subsequently, valuable test results have been produced. In the mean time, a simulation model for the particular tri-generation system has been established by integrating the component models of the system in accordance with the components' actual flow paths and energy streams. These component models, which include a compressor, recuperator, combustion chamber, gas turbine, electric generator, gas pipes, generator (desorber), rectifier, absorbers, condenser and evaporator etc., were developed based upon the balance of heat and mass. The calculations of heat transfer and phase equilibrium were included in the component models and chemical reaction balances were considered in the model of the combustion chamber. The system model has been validated with the test results and has consequently been used to predict the system performance at different operating and design conditions, such as varied ambient temperature, fuel flow rate and pressure ratio etc. The ultimate results of the performance analysis formulated by the system model can contribute significantly to the optimal component and system designs in various practical applications. (author)

  8. Performance and cost evaluation of health information systems using micro-costing and discrete-event simulation.

    Science.gov (United States)

    Rejeb, Olfa; Pilet, Claire; Hamana, Sabri; Xie, Xiaolan; Durand, Thierry; Aloui, Saber; Doly, Anne; Biron, Pierre; Perrier, Lionel; Augusto, Vincent

    2018-06-01

    Innovation and health-care funding reforms have contributed to the deployment of Information and Communication Technology (ICT) to improve patient care. Many health-care organizations considered the application of ICT as a crucial key to enhance health-care management. The purpose of this paper is to provide a methodology to assess the organizational impact of high-level Health Information System (HIS) on patient pathway. We propose an integrated performance evaluation of HIS approach through the combination of formal modeling using the Architecture of Integrated Information Systems (ARIS) models, a micro-costing approach for cost evaluation, and a Discrete-Event Simulation (DES) approach. The methodology is applied to the consultation for cancer treatment process. Simulation scenarios are established to conclude about the impact of HIS on patient pathway. We demonstrated that although high level HIS lengthen the consultation, occupation rate of oncologists are lower and quality of service is higher (through the number of available information accessed during the consultation to formulate the diagnostic). The provided method allows also to determine the most cost-effective ICT elements to improve the care process quality while minimizing costs. The methodology is flexible enough to be applied to other health-care systems.

  9. Physical Protection System Upgrades - Optimizing for Performance and Cost

    International Nuclear Information System (INIS)

    Hicks, Mary Jane; Bouchard, Ann M.

    1999-01-01

    CPA--Cost and Performance Analysis--is an architecture that supports analysis of physical protection systems and upgrade options. ASSESS (Analytic System and Software for Evaluating Security Systems), a tool for evaluating performance of physical protection systems, currently forms the cornerstone for evaluating detection probabilities and delay times of the system. Cost and performance data are offered to the decision-maker at the systems level and to technologists at the path-element level. A new optimization engine has been attached to the CPA methodology to automate analyses of many combinations (portfolios) of technologies. That engine controls a new analysis sequencer that automatically modifies ASSESS PPS files (facility descriptions), automatically invokes ASSESS Outsider analysis and then saves results for post-processing. Users can constrain the search to an upper bound on total cost, to a lower bound on level of performance, or to include specific technologies or technology types. This process has been applied to a set of technology development proposals to identify those portfolios that provide the most improvement in physical security for the lowest cost to install, operate and maintain at a baseline facility

  10. Improvement an enterprises marketing performance measurement system

    Directory of Open Access Journals (Sweden)

    Stanković Ljiljana

    2013-01-01

    Full Text Available Business conditions in which modern enterprises do business are more and more complex. The complexity of the business environment is caused by activities of external and internal factors, which imposes the need for the turn in management focus. One of key turns is related to the need of adaptation and development of new business performance evaluation systems. The evaluation of marketing contribution to business performance is very important however a complex task as well. The marketing theory and practice indicates the need for developing adequate standards and systems for evaluating the efficiency of marketing decisions. The better understanding of marketing standards and ways that managers use is a very important factor that affects the efficiency of strategic decision-making. The paper presents the results of researching the way in which managers perceive and apply marketing performance measures. The data that were received through the field research sample enabled the consideration of the managers' attitudes on practical ways of implementing marketing performance measurement and identifying measures that managers imply as used mostly in business practice.

  11. Performance evaluation of microturbine generation system for microgrid applications

    Energy Technology Data Exchange (ETDEWEB)

    Salam, A.A.; Mohamed, A.; Hannan, M.A.; Shareef, H.; Wanik, M.Z.C. [Kebangsaan Malaysia Univ., Selangor (Malaysia). Dept. of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment

    2009-03-11

    A control system for microturbine generation system (MGS) units in microgrid applications was presented. A dynamic model of the microturbine and power electronics interface systems was used to determine converter control strategies for distributed generation operation. Back-to-back converters were used to interface the microturbine-based distributed generation system to the grid. The controllers were used to regulate the output voltage value at the reference bus voltage and the frequency of the whole grid. Reference values were predetermined in the control scheme in order to obtain the desired value of voltage amplitude and frequency. An investigation of system dynamics was conducted using simulations in both grid-connected and islanded modes. Results of the simulations demonstrated the ability of the MGS to improve electricity grid reliability. The model can be used to accurately simulate MGS dynamic performance for both grid- and islanded modes of operation. 10 refs., 17 figs.

  12. Tuning HDF5 subfiling performance on parallel file systems

    Energy Technology Data Exchange (ETDEWEB)

    Byna, Suren [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chaarawi, Mohamad [Intel Corp. (United States); Koziol, Quincey [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mainzer, John [The HDF Group (United States); Willmore, Frank [The HDF Group (United States)

    2017-05-12

    Subfiling is a technique used on parallel file systems to reduce locking and contention issues when multiple compute nodes interact with the same storage target node. Subfiling provides a compromise between the single shared file approach that instigates the lock contention problems on parallel file systems and having one file per process, which results in generating a massive and unmanageable number of files. In this paper, we evaluate and tune the performance of recently implemented subfiling feature in HDF5. In specific, we explain the implementation strategy of subfiling feature in HDF5, provide examples of using the feature, and evaluate and tune parallel I/O performance of this feature with parallel file systems of the Cray XC40 system at NERSC (Cori) that include a burst buffer storage and a Lustre disk-based storage. We also evaluate I/O performance on the Cray XC30 system, Edison, at NERSC. Our results show performance benefits of 1.2X to 6X performance advantage with subfiling compared to writing a single shared HDF5 file. We present our exploration of configurations, such as the number of subfiles and the number of Lustre storage targets to storing files, as optimization parameters to obtain superior I/O performance. Based on this exploration, we discuss recommendations for achieving good I/O performance as well as limitations with using the subfiling feature.

  13. Solar energy system performance evaluation: Honeywell OTS 41, Shenandoah (Newman), Georgia

    Science.gov (United States)

    Mathur, A. K.; Pederson, S.

    1982-08-01

    The operation and technical performance of the Solar Operational Test Site (OTS 41) located at Shenandoah, Georgia, are described, based on the analysis of the data collected between January and August 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 41 is a hydronic heating and cooling system consisting of 702 square feet of liquid-cooled flat-plate collectors; a 1000-gallon thermal storage tank; a 3-ton capacity organic Rankine-cycle-engine-assisted air conditioner; a water-to-are heat exchanger for solar space heating; a finned-tube coil immersed in the storage tank to preheat water for a gas-fired hot water heater; and associated piping, pumps, valves, and controls. The solar system has six basic modes of operation and several combination modes. The system operation is controlled automatically by a Honeywell-designed microprocessor-based control system, which also provides diagnostics.

  14. Study on evaluation index system of operational performance of municipal wastewater treatment plants in China

    Science.gov (United States)

    Xiaoxin, Zhang; Jin, Huang; Ling, Lin; Yan, Li

    2018-05-01

    According to the undeveloped evaluation method for the operational performance of the municipal wastewater treatment plants, this paper analyzes the policies related to sewage treatment industry based on the investigation of the municipal wastewater treatment plants. The applicable evaluation method for the operational performance was proposed from environmental protection performance, resources and energy consumption, technical and economic performance, production management and main equipment, providing a reliable basis for scientific evaluation of the operation as well as improving the operational performance of municipal wastewater treatment plant.

  15. Standardizing the performance evaluation of short-term wind prediction models

    DEFF Research Database (Denmark)

    Madsen, Henrik; Pinson, Pierre; Kariniotakis, G.

    2005-01-01

    Short-term wind power prediction is a primary requirement for efficient large-scale integration of wind generation in power systems and electricity markets. The choice of an appropriate prediction model among the numerous available models is not trivial, and has to be based on an objective...... evaluation of model performance. This paper proposes a standardized protocol for the evaluation of short-term wind-poser preciction systems. A number of reference prediction models are also described, and their use for performance comparison is analysed. The use of the protocol is demonstrated using results...... from both on-shore and off-shore wind forms. The work was developed in the frame of the Anemos project (EU R&D project) where the protocol has been used to evaluate more than 10 prediction systems....

  16. The readout performance evaluation of PowerPC

    International Nuclear Information System (INIS)

    Chu Yuanping; Zhang Hongyu; Zhao Jingwei; Ye Mei; Tao Ning; Zhu Kejun; Tang Suqiu; Guo Yanan

    2003-01-01

    PowerPC, as a powerful low-cost embedded computer, is one of the very important research objects in recent years in the project of BESIII data acquisition system. The researches on the embedded system and embedded computer have achieved many important results in the field of High Energy Physics especially in the data acquisition system. The one of the key points to design an acquisition system using PowerPC is to evaluate the readout ability of PowerPC correctly. The paper introduce some tests for the PowerPC readout performance. (authors)

  17. Design and performance evaluation of a broadband three dimensional acoustic intensity measuring system.

    Science.gov (United States)

    Miah, Khalid H; Hixon, Elmer L

    2010-04-01

    A seven-microphone three dimensional (3D) intensity measuring system has been developed and evaluated for performance for a broad frequency band (200 Hz-6.5 kHz). Six microphones are arranged in a concentric array with one microphone at the center of the probe. The screw adjustable center microphone is the probe reference microphone, and is used for calibrations of the other microphones in the probe. This probe addresses limitations of the traditional two-microphone system in measuring acoustical properties in a 3D space from the one dimensional measurements. This probe also eliminates the need of spacers used in the existing 3D probes for broadband measurements. Diffraction and reflection effects on calibrations due to presence of the microphones and the probe supporting structure are negligible. This seven-microphone probe provided better results in the intensity measurements for the wide frequency band than that of a similar four-microphone array probe.

  18. Field experience and performance evaluation of a medium-concentration CPV system

    Science.gov (United States)

    Norton, Matthew; Bentley, Roger; Georghiou, George E.; Chonavel, Sylvain; De Mutiis, Alfredo

    2012-10-01

    With the aim of gaining experience and performance data from location with a harsh summer climate, a 70 X concentrating photovoltaic (CPV) system was installed in Janurary 2009 in Nicosia, Cyprus. The performance of this system has been monitored using regular current-voltage characterisations for three years. Over this period, the output of the system has remained fairly constant. Measured performance ratios varied from 0.79 to 0.86 in the winter, but fell to 0.64 over the year when left uncleaned. Operating cell temperatures were modeled and found to be similar to those of flat plate modules. The most significant causes of energy loss have been identified as originating from tracking issues and soiling. Losses due to soiling could account for a drop in output of 0.2% per day. When cleaned and properly oriented, the normalized output of the system has remained constant, suggesting that this particular design is tolerant to the physical strain of long-term outdoor exposure in harsh summer conditions. Regular cleaning and reliable tracker operation are shown to be essential for maximizing energy yield.

  19. Evaluating building performance in healthcare facilities: an organizational perspective.

    Science.gov (United States)

    Steinke, Claudia; Webster, Lynn; Fontaine, Marie

    2010-01-01

    Using the environment as a strategic tool is one of the most cost-effective and enduring approaches for improving public health; however, it is one that requires multiple perspectives. The purpose of this article is to highlight an innovative methodology that has been developed for conducting comprehensive performance evaluations in public sector health facilities in Canada. The building performance evaluation methodology described in this paper is a government initiative. The project team developed a comprehensive building evaluation process for all new capital health projects that would respond to the aforementioned need for stakeholders to be more accountable and to better integrate the larger organizational strategy of facilities. The Balanced Scorecard, which is a multiparadigmatic, performance-based business framework, serves as the underlying theoretical framework for this initiative. It was applied in the development of the conceptual model entitled the Building Performance Evaluation Scorecard, which provides the following benefits: (1) It illustrates a process to link facilities more effectively to the overall mission and goals of an organization; (2) It is both a measurement and a management system that has the ability to link regional facilities to measures of success and larger business goals; (3) It provides a standardized methodology that ensures consistency in assessing building performance; and (4) It is more comprehensive than traditional building evaluations. The methodology presented in this paper is both a measurement and management system that integrates the principles of evidence-based design with the practices of pre- and post-occupancy evaluation. It promotes accountability and continues throughout the life cycle of a project. The advantage of applying this framework is that it engages health organizations in clarifying a vision and strategy for their facilities and helps translate those strategies into action and measurable performance

  20. Evaluation of real time operating system

    International Nuclear Information System (INIS)

    Lee, Cheol Hoon; Cho, Moon Heang; Choi, In Bum; Lee, Jung Won; Kang, Hui Sung

    2006-02-01

    An hard RTOS used in the Nuclear Power Plants must satisfy severe performance requirements even in a worst case scenario. Since operating systems are becoming more complicated, it is not an easy job to evaluate them. So it becomes more important how to evaluate the RTOS's used in the Nuclear Power Plants. The purpose of this work is to survey design examples and performance models of RTOS's used in the nuclear power plants and based on this survey, develop a evaluation technologies

  1. Evaluation of FSO System Availability in Haze Condition

    Science.gov (United States)

    Anis, A. A.; Rashidi, C. B. M.; Aljunid, S. A.; Rahman, A. K.

    2018-03-01

    In this paper, we proposed the evaluation of FSO system availability in haze condition. The atmospheric attenuation by weather conditions in the atmosphere as the most challenging problem of FSO system as the system performance is severely degraded and causing the signal optic to be transmitted poorly. The effects of haze condition on the performance of FSO system is stressed out and focused in this paper. From the evaluation of the analysis, designs of FSO system are proposed to obtain a system with improved link performance in haze conditions. The scattering coefficient and the atmospheric attenuation are determined using Beer’s Lambert equation. From the research, the link performance of the system is greatly improved using Design 2 with minimum BER of 10-127127 and maximu m Q Factor of 23.98. The FSO system using Design 2 has better performance compared to Design 1 in haze condition as the optical signals could penetrate the dense haze better without losing much optical power during the transmission to the scattering.

  2. Performance Evaluations: Bridging the Gap between Today's Goals and Tomorrow's Reality.

    Science.gov (United States)

    Conry, Terry; Kemper, Jim

    1993-01-01

    This article argues that a sound performance evaluation system benefits the employee, supervisor, and organization by providing a written record of efforts, by motivating employees, and by maximizing employee growth potential. It proposes that such performance evaluations are compatible with the Total Quality Management approach. Principles of…

  3. A resilience-based model for performance evaluation of information systems: the case of a gas company

    Science.gov (United States)

    Azadeh, A.; Salehi, V.; Salehi, R.

    2017-10-01

    Information systems (IS) are strongly influenced by changes in new technology and should react swiftly in response to external conditions. Resilience engineering is a new method that can enable these systems to absorb changes. In this study, a new framework is presented for performance evaluation of IS that includes DeLone and McLean's factors of success in addition to resilience. Hence, this study is an attempt to evaluate the impact of resilience on IS by the proposed model in Iranian Gas Engineering and Development Company via the data obtained from questionnaires and Fuzzy Data Envelopment Analysis (FDEA) approach. First, FDEA model with α-cut = 0.05 was identified as the most suitable model to this application by performing all Banker, Charnes and Cooper and Charnes, Cooper and Rhodes models of and FDEA and selecting the appropriate model based on maximum mean efficiency. Then, the factors were ranked based on the results of sensitivity analysis, which showed resilience had a significantly higher impact on the proposed model relative to other factors. The results of this study were then verified by conducting the related ANOVA test. This is the first study that examines the impact of resilience on IS by statistical and mathematical approaches.

  4. Evaluating cryostat performance for naval applications

    Science.gov (United States)

    Knoll, David; Willen, Dag; Fesmire, James; Johnson, Wesley; Smith, Jonathan; Meneghelli, Barry; Demko, Jonathan; George, Daniel; Fowler, Brian; Huber, Patti

    2012-06-01

    The Navy intends to use High Temperature Superconducting Degaussing (HTSDG) coil systems on future Navy platforms. The Navy Metalworking Center (NMC) is leading a team that is addressing cryostat configuration and manufacturing issues associated with fabricating long lengths of flexible, vacuum-jacketed cryostats that meet Navy shipboard performance requirements. The project includes provisions to evaluate the reliability performance, as well as proofing of fabrication techniques. Navy cryostat performance specifications include less than 1 Wm-1 heat loss, 2 MPa working pressure, and a 25-year vacuum life. Cryostat multilayer insulation (MLI) systems developed on the project have been validated using a standardized cryogenic test facility and implemented on 5-meterlong test samples. Performance data from these test samples, which were characterized using both LN2 boiloff and flow-through measurement techniques, will be presented. NMC is working with an Integrated Project Team consisting of Naval Sea Systems Command, Naval Surface Warfare Center-Carderock Division, Southwire Company, nkt cables, Oak Ridge National Laboratory (ORNL), ASRC Aerospace, and NASA Kennedy Space Center (NASA-KSC) to complete these efforts. Approved for public release; distribution is unlimited. This material is submitted with the understanding that right of reproduction for governmental purposes is reserved for the Office of Naval Research, Arlington, Virginia 22203-1995.

  5. Performance of deep geothermal energy systems

    Science.gov (United States)

    Manikonda, Nikhil

    Geothermal energy is an important source of clean and renewable energy. This project deals with the study of deep geothermal power plants for the generation of electricity. The design involves the extraction of heat from the Earth and its conversion into electricity. This is performed by allowing fluid deep into the Earth where it gets heated due to the surrounding rock. The fluid gets vaporized and returns to the surface in a heat pipe. Finally, the energy of the fluid is converted into electricity using turbine or organic rankine cycle (ORC). The main feature of the system is the employment of side channels to increase the amount of thermal energy extracted. A finite difference computer model is developed to solve the heat transport equation. The numerical model was employed to evaluate the performance of the design. The major goal was to optimize the output power as a function of parameters such as thermal diffusivity of the rock, depth of the main well, number and length of lateral channels. The sustainable lifetime of the system for a target output power of 2 MW has been calculated for deep geothermal systems with drilling depths of 8000 and 10000 meters, and a financial analysis has been performed to evaluate the economic feasibility of the system for a practical range of geothermal parameters. Results show promising an outlook for deep geothermal systems for practical applications.

  6. SIMS prototype system 4 - performance test report

    Science.gov (United States)

    1978-01-01

    A self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water was evaluated. Data analysis is included which documents the system performance and verifies its suitability for field installation.

  7. Performance evaluations of a geothermal power plant

    International Nuclear Information System (INIS)

    Coskun, C.; Oktay, Z.; Dincer, I.

    2011-01-01

    Thermodynamic analysis of an operational 7.5 MWe binary geothermal power plant in Tuzla-Turkey is performed, through energy and exergy, using actual plant data to assess its energetic and exergetic performances. Eight performance-related parameters, namely total exergy destruction ratio, component exergy destruction ratio, dimensionless exergy destruction, energetic renewability ratio, exergetic renewability ratio, energetic reinjection ratio, exergetic reinjection ratio and improvement potential are investigated. Energy and exergy losses/destructions for the plant and its units are determined and illustrated using energy and exergy flow diagrams. The largest energy and exergy losses occur in brine reinjection unit. The variation of the plant energy efficiency is found between 6% and 12%. Exergy efficiency values change between 35 and 49%. The annual average energy and exergy efficiencies are found as 9.47% and 45.2%, respectively. - Highlights: → Investigation of a geothermal system energetically and exergetically. → Performance assessment of the system through energy and exergy efficiencies. → Utilization of temperature distribution in exergy calculations. → Evaluation of eight energetic and exergetic parameters for the system.

  8. Evaluation of real time operating system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Hoon; Cho, Moon Heang; Choi, In Bum; Lee, Jung Won; Kang, Hui Sung [Chungnam National Univ., Daejeon (Korea, Republic of)

    2006-02-15

    An hard RTOS used in the Nuclear Power Plants must satisfy severe performance requirements even in a worst case scenario. Since operating systems are becoming more complicated, it is not an easy job to evaluate them. So it becomes more important how to evaluate the RTOS's used in the Nuclear Power Plants. The purpose of this work is to survey design examples and performance models of RTOS's used in the nuclear power plants and based on this survey, develop a evaluation technologies.

  9. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  10. Business School's Performance Management System Standards Design

    Science.gov (United States)

    Azis, Anton Mulyono; Simatupang, Togar M.; Wibisono, Dermawan; Basri, Mursyid Hasan

    2014-01-01

    This paper aims to compare various Performance Management Systems (PMS) for business school in order to find the strengths of each standard as inputs to design new model of PMS. There are many critical aspects and gaps notified for new model to improve performance and even recognized that self evaluation performance management is not well…

  11. Performance evaluation of the reference system for calibration of IPEN activities

    International Nuclear Information System (INIS)

    Martins, Elaine Wirney; Potiens, Maria da Penha A.

    2011-01-01

    The formation of good quality image in nuclear medicine services depends on several factors, including the radiopharmaceutical activity, which must be well determined by a specific apparatus, in perfect operating condition, called activimeter. Therefore, the establishment of a quality control program for measuring the radiopharmaceuticals radioactivity before being administered to the patient is crucial to the safe and effective use of the radiopharmaceuticals used in diagnostic and therapeutical procedures. Two activimeters, belonging by the Laboratorio de Calibracao do Instrumentos (LCI) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), were evaluated: the secondary standard system NPL-CRC radionuclide calibrator, manufactured by Southern Scientific, and the work standard system CRC-15BT with traceability to National Institute of Standard and Technology (NIST). A set of standard sources of the radionuclides 1 '3 3 Ba, 57 Co and 137 Cs was used as reference to perform the quality control tests. The precision, accuracy and repeatability tests were in agreement with those established by the CNEN-NE 3.05 Brazilian standard, which recommends the variation limit of up to 10%, 5% and 5% respectively. The results obtained for the reproducibility tests presented a variation always below 1,5%, which means it is within the IEC 61674 international standard recommendation of up to 3%. Activimeters response regarding linearity showed concordance between the measured activities and the theoretical curve for both activimeters. (author)

  12. Low cost data acquisition module for evaluating the quantitative performance of daylight systems

    Energy Technology Data Exchange (ETDEWEB)

    Ciampini, F.; Scarazzato, P.S. [Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, P.O. Box 6021, CEP 13083-852 Campinas (Brazil); Neves, A.A.R. [Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin, Departamento de Eletronica Quantica, P.O. Box 6165, 13083-970 Campinas (Brazil); Pereira, D.C.L.; Yamanaka, M.H. [Universidade de Sao Paulo, Faculdade de Arquitetura e Urbanismo, Departamento de Tecnologia da Arquitetura, Rua do Lago, 878 CEP 05508-080, Sao Paulo (Brazil)

    2007-09-15

    The search for efficient, auto-sustainable constructions that allows the user a contact with the outer environment has stimulated the development of advanced strategies, in various devices, for the exploitation of the daylight. A low cost data acquisition system was developed in this study, to observe the distribution of the natural light inside a prototype and to evaluate the quantitative performance for redirecting systems. The luminous sensor is a light dependent resistor, that responds to the illuminance with a reduction in the resistance when illuminated, through a log-log dependence. Calibration curves are set up to relate the change of resistance to absolute illuminance. It therefore provides a continuous investigation of the illuminance for various sampled points in the interior test space with a 0.03% digital error due to the 12-bit resolution. The final measured error of 5% is mainly due to the system calibration and resistance memory history. The circuit connects to a standard parallel port of any Personal Computer and supplies 64 analog inputs, one for each luminous sensor. The circuit can be easily modified to attend different quantities of analog inputs or communication ports. (author)

  13. A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system.

    Science.gov (United States)

    Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan

    2015-10-01

    An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.

  14. Performance Evaluation of a Multipurpose Bare PC Gateway

    DEFF Research Database (Denmark)

    Tsetse, Anthony; Appiah-Kubi, Patrick; Loukili, Alae

    2015-01-01

    . Different solutions (6to4 tunneling, IVI translation, NAT64, DNS64 etc.), have being proposed but these are all standalone systems. In this paper we discuss the design,implementation and performance evaluation of a multipurpose Bare PC Gateway which incorporates Network Address translation (NAT), 6to4...... results indicate a relatively better performance (18%-45%) of the Bare PC gateway compared to a Linux gateway (running the functionalities as standalone systems). We believe the proposed solution could easily scale to wide area networks and also provide a cost efficient solution...

  15. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Quan Chen

    2018-01-01

    Full Text Available Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees’ low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees’ job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice.

  16. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation

    Science.gov (United States)

    Chen, Quan; Tsai, Sang-Bing; Zhou, Jie; Yu, Jian; Chang, Li-Chung; Li, Guodong; Zheng, Yuxiang; Wang, Jiangtao

    2018-01-01

    Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees’ low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees’ job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice. PMID:29301375

  17. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation.

    Science.gov (United States)

    Chen, Quan; Tsai, Sang-Bing; Zhai, Yuming; Zhou, Jie; Yu, Jian; Chang, Li-Chung; Li, Guodong; Zheng, Yuxiang; Wang, Jiangtao

    2018-01-03

    Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees' low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees' job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice.

  18. Performance assessment techniques for groundwater recovery and treatment systems

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, G.L. [Environmental Resources Management, Inc., Exton, PA (United States)

    1993-03-01

    Groundwater recovery and treatment (pump and treat systems) continue to be the most commonly selected remedial technology for groundwater restoration and protection programs at hazardous waste sites and RCRA facilities nationwide. Implementing a typical groundwater recovery and treatment system includes the initial assessment of groundwater quality, characterizing aquifer hydrodynamics, recovery system design, system installation, testing, permitting, and operation and maintenance. This paper focuses on methods used to assess the long-term efficiency of a pump and treat system. Regulatory agencies and industry alike are sensitive to the need for accurate assessment of the performance and success of groundwater recovery systems for contaminant plume abatement and aquifer restoration. Several assessment methods are available to measure the long-term performance of a groundwater recovery system. This paper presents six assessment techniques: degree of compliance with regulatory agency agreement (Consent Order of Record of Decision), hydraulic demonstration of system performance, contaminant mass recovery calculation, system design and performance comparison, statistical evaluation of groundwater quality and preferably, integration of the assessment methods. Applying specific recovery system assessment methods depends upon the type, amount, and quality of data available. Use of an integrated approach is encouraged to evaluate the success of a groundwater recovery and treatment system. The methods presented in this paper are for engineers and corporate management to use when discussing the effectiveness of groundwater remediation systems with their environmental consultant. In addition, an independent (third party) system evaluation is recommended to be sure that a recovery system operates efficiently and with minimum expense.

  19. Performance Evaluation Methods for Assistive Robotic Technology

    Science.gov (United States)

    Tsui, Katherine M.; Feil-Seifer, David J.; Matarić, Maja J.; Yanco, Holly A.

    Robots have been developed for several assistive technology domains, including intervention for Autism Spectrum Disorders, eldercare, and post-stroke rehabilitation. Assistive robots have also been used to promote independent living through the use of devices such as intelligent wheelchairs, assistive robotic arms, and external limb prostheses. Work in the broad field of assistive robotic technology can be divided into two major research phases: technology development, in which new devices, software, and interfaces are created; and clinical, in which assistive technology is applied to a given end-user population. Moving from technology development towards clinical applications is a significant challenge. Developing performance metrics for assistive robots poses a related set of challenges. In this paper, we survey several areas of assistive robotic technology in order to derive and demonstrate domain-specific means for evaluating the performance of such systems. We also present two case studies of applied performance measures and a discussion regarding the ubiquity of functional performance measures across the sampled domains. Finally, we present guidelines for incorporating human performance metrics into end-user evaluations of assistive robotic technologies.

  20. Evaluating Innovations in Home Care for Performance Accountability.

    Science.gov (United States)

    Collister, Barbara; Gutscher, Abram; Ambrogiano, Jana

    2016-01-01

    Concerns about rising costs and the sustainability of our healthcare system have led to a drive for innovative solutions and accountability for performance. Integrated Home Care, Calgary Zone, Alberta Health Services went beyond traditional accountability measures to use evaluation methodology to measure the progress of complex innovations to its organization structure and service delivery model. This paper focuses on the first two phases of a three-phase evaluation. The results of the first two phases generated learning about innovation adoption and sustainability, and performance accountability at the program-level of a large publicly funded healthcare organization.

  1. Evaluation methodologies for security testing biometric systems beyond technological evaluation

    OpenAIRE

    Fernández Saavedra, María Belén

    2013-01-01

    The main objective of this PhD Thesis is the specification of formal evaluation methodologies for testing the security level achieved by biometric systems when these are working under specific contour conditions. This analysis is conducted through the calculation of the basic technical biometric system performance and its possible variations. To that end, the next two relevant contributions have been developed. The first contribution is the definition of two independent biometric performance ...

  2. Evaluation methodology for fixed-site physical protection systems

    International Nuclear Information System (INIS)

    Bennett, H.A.; Olascoaga, M.T.

    1980-01-01

    A system performance evaluation methodology has been developed to aid the Nuclear Regulatory Commission (NRC) in the implementation of new regulations designed to upgrade the physical protection of nuclear fuel cycle facilities. The evaluation methodology, called Safeguards Upgrade Rule Evaluation (SURE), provides a means of explicitly incorporating measures for highly important and often difficult to quantify performance factors, e.g., installation, maintenance, training and proficiency levels, compatibility of components in subsystems, etc. This is achieved by aggregating responses to component and system questionaires through successive levels of a functional hierarchy developed for each primary performance capability specified in the regulations, 10 CFR 73.45. An overall measure of performance for each capability is the result of this aggregation process. This paper provides a descripton of SURE

  3. Environmental performance evaluation of hot water supplying systems for domestic use

    Directory of Open Access Journals (Sweden)

    Luiz Alexandre Kulay

    2015-04-01

    Full Text Available The consumption profile of Brazilian citizens is changing as alternatives are sought to reduce costs. A major focus of this change of attitude involves expenditures for electricity, particularly in relation to water heating systems. The manufacturers of these devices add value to their products beyond price. A usual strategy is the enhancement of the environmental performance of the product. This study compared four water heating systems: electric, gas, solar and hybrid, using an environmental perspective. The systems were operated under similar conditions. The analysis was conducted by using the Life Cycle Assessment technique, for the impact categories of Climate Change, Acidification Eutrophication and Water, Metal and Fossil Resource depletion. The results indicated that the electric and hybrid systems are less harmful to the environment for all the impact categories under analysis. On the other hand, the gas system provided the worst performance of the group. The solar heating system was penalized due to its dependence on electricity to operate under the conditions in which the study was conducted.

  4. Evaluation of the Quality of Occupational Health and Safety Management Systems Based on Key Performance Indicators in Certified Organizations.

    Science.gov (United States)

    Mohammadfam, Iraj; Kamalinia, Mojtaba; Momeni, Mansour; Golmohammadi, Rostam; Hamidi, Yadollah; Soltanian, Alireza

    2017-06-01

    Occupational Health and Safety Management Systems are becoming more widespread in organizations. Consequently, their effectiveness has become a core topic for researchers. This paper evaluates the performance of the Occupational Health and Safety Assessment Series 18001 specification in certified companies in Iran. The evaluation is based on a comparison of specific criteria and indictors related to occupational health and safety management practices in three certified and three noncertified companies. Findings indicate that the performance of certified companies with respect to occupational health and safety management practices is significantly better than that of noncertified companies. Occupational Health and Safety Assessment Series 18001-certified companies have a better level of occupational health and safety; this supports the argument that Occupational Health and Safety Management Systems play an important strategic role in health and safety in the workplace.

  5. Performance evaluation of an automotive thermoelectric generator

    Science.gov (United States)

    Dubitsky, Andrei O.

    Around 40% of the total fuel energy in typical internal combustion engines (ICEs) is rejected to the environment in the form of exhaust gas waste heat. Efficient recovery of this waste heat in automobiles can promise a fuel economy improvement of 5%. The thermal energy can be harvested through thermoelectric generators (TEGs) utilizing the Seebeck effect. In the present work, a versatile test bench has been designed and built in order to simulate conditions found on test vehicles. This allows experimental performance evaluation and model validation of automotive thermoelectric generators. An electrically heated exhaust gas circuit and a circulator based coolant loop enable integrated system testing of hot and cold side heat exchangers, thermoelectric modules (TEMs), and thermal interface materials at various scales. A transient thermal model of the coolant loop was created in order to design a system which can maintain constant coolant temperature under variable heat input. Additionally, as electrical heaters cannot match the transient response of an ICE, modelling was completed in order to design a relaxed exhaust flow and temperature history utilizing the system thermal lag. This profile reduced required heating power and gas flow rates by over 50%. The test bench was used to evaluate a DOE/GM initial prototype automotive TEG and validate analytical performance models. The maximum electrical power generation was found to be 54 W with a thermal conversion efficiency of 1.8%. It has been found that thermal interface management is critical for achieving maximum system performance, with novel designs being considered for further improvement.

  6. Development of Probabilistic Performance Evaluation Procedure for Umbilical Lines of Seismically Isolated NPPs

    International Nuclear Information System (INIS)

    Hahm, Daegi; Park, Junhee; Choi, Inkil

    2013-01-01

    In this study, we proposed a procedure to perform the probabilistic performance evaluation of interface piping system for seismically isolated NPPs, and carried out the preliminary performance evaluation of the target example umbilical line. For EDB level earthquakes, the target performance goal cannot be fulfilled, but we also find out that the result can be changed with respect to the variation of the assumed values, i. e., the distribution of response, and the limit state of piping system. Recently, to design the nuclear power plants (NPPs) more efficiently and safely against the strong seismic load, many researchers focus on the seismic isolation system. For the adoption of seismic isolation system to the NPPs, the seismic performance of isolation devices, structures, and components should be guaranteed firstly. Hence, some researches were performed to determine the seismic performance of such items. For the interface piping system between isolated structure and non-isolated structure, the seismic capacity should be carefully estimated since that the required displacement absorption capacity will be increased significantly by the adoption of the seismic isolation system. Nowadays, in NUREG report, the probabilistic performance criteria for isolated NPP structures and components are proposed. Hence, in this study, we developed the probabilistic performance evaluation method and procedure for interface piping system, and applied the method to an example pipe. The detailed procedure and main results are summarized in next section. For the interface piping system, the seismic capacity should be carefully estimated since that the required displacement absorption capacity will be increased significantly by the adoption of the seismic isolation system

  7. Integrated Main Propulsion System Performance Reconstruction Process/Models

    Science.gov (United States)

    Lopez, Eduardo; Elliott, Katie; Snell, Steven; Evans, Michael

    2013-01-01

    The Integrated Main Propulsion System (MPS) Performance Reconstruction process provides the MPS post-flight data files needed for postflight reporting to the project integration management and key customers to verify flight performance. This process/model was used as the baseline for the currently ongoing Space Launch System (SLS) work. The process utilizes several methodologies, including multiple software programs, to model integrated propulsion system performance through space shuttle ascent. It is used to evaluate integrated propulsion systems, including propellant tanks, feed systems, rocket engine, and pressurization systems performance throughout ascent based on flight pressure and temperature data. The latest revision incorporates new methods based on main engine power balance model updates to model higher mixture ratio operation at lower engine power levels.

  8. Solar Thermal System Evaluation in China

    Directory of Open Access Journals (Sweden)

    Xinyu Zhang

    2015-01-01

    Full Text Available More than 581 solar thermal systems (STSs, 98 counties, and 47 renewable application demonstration cites in China need to be inspected by the end of 2015. In this study, the baseline for performance and economic evaluation of STSs are presented based on the site test data and related references. An index used to evaluate STSs was selected, and methods to acquire the parameters used to calculate the related index were set. The requirements for sensors for testing were specified. The evaluation method was applied to three systems and the result shows that the evaluation method is suitable for the evaluation of STSs in China.

  9. Design and Performance Evaluation of Real-time Endovascular Interventional Surgical Robotic System with High Accuracy.

    Science.gov (United States)

    Wang, Kundong; Chen, Bing; Lu, Qingsheng; Li, Hongbing; Liu, Manhua; Shen, Yu; Xu, Zhuoyan

    2018-05-15

    Endovascular interventional surgery (EIS) is performed under a high radiation environment at the sacrifice of surgeons' health. This paper introduces a novel endovascular interventional surgical robot that aims to reduce radiation to surgeons and physical stress imposed by lead aprons during fluoroscopic X-ray guided catheter intervention. The unique mechanical structure allowed the surgeon to manipulate the axial and radial motion of the catheter and guide wire. Four catheter manipulators (to manipulate the catheter and guide wire), and a control console which consists of four joysticks, several buttons and two twist switches (to control the catheter manipulators) were presented. The entire robotic system was established on a master-slave control structure through CAN (Controller Area Network) bus communication, meanwhile, the slave side of this robotic system showed highly accurate control over velocity and displacement with PID controlling method. The robotic system was tested and passed in vitro and animal experiments. Through functionality evaluation, the manipulators were able to complete interventional surgical motion both independently and cooperatively. The robotic surgery was performed successfully in an adult female pig and demonstrated the feasibility of superior mesenteric and common iliac artery stent implantation. The entire robotic system met the clinical requirements of EIS. The results show that the system has the ability to imitate the movements of surgeons and to accomplish the axial and radial motions with consistency and high-accuracy. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Evaluation model based on FAHP for nuclear power project contract performance

    International Nuclear Information System (INIS)

    Liu Bohang; Cheng Jing

    2012-01-01

    Fuzzy Comprehensive Evaluation is a common tool to analyze comprehensive integration. Fuzzy Analytic Hierarchy Process is an improvement for Analytic Hierarchy Process. Firstly the paper pointed out the concept of FAHP, and then used FAHP to setup an evaluation system model for nuclear power project contract performance. Based on this model, all the evaluation factors were assigned to different weightiness. By weighting the score of each factor, output would be the result which could evaluate the contract performance. On the basis of the research, the paper gave the principle of evaluating contract performance of nuclear power suppliers, which can assure the procurement process. (authors)

  11. Performance Evaluation of Two Different Usability Evaluation Methods in the Context of Collaborative Writing Systems

    OpenAIRE

    Bakhtyar, Shoaib; Afridi, Qaisar Zaman

    2010-01-01

    In today’s world of rapid technological development one cannot deny the importance of collaborative writing systems. Besides many advantages of a collaborative writing system the major one is to allow its end users to work in collaboration with each other without having to physically meet. In the past various researches has been carried out for the usability evaluation of collaborative writing systems using the think aloud protocol method however there is no study conducted on the comparison ...

  12. High Pressure Electrolyzer System Evaluation

    Science.gov (United States)

    Prokopius, Kevin; Coloza, Anthony

    2010-01-01

    This report documents the continuing efforts to evaluate the operational state of a high pressure PEM based electrolyzer located at the NASA Glenn Research Center. This electrolyzer is a prototype system built by General Electric and refurbished by Hamilton Standard (now named Hamilton Sunstrand). It is capable of producing hydrogen and oxygen at an output pressure of 3000 psi. The electrolyzer has been in storage for a number of years. Evaluation and testing was performed to determine the state of the electrolyzer and provide an estimate of the cost for refurbishment. Pressure testing was performed using nitrogen gas through the oxygen ports to ascertain the status of the internal membranes and seals. It was determined that the integrity of the electrolyzer stack was good as there were no appreciable leaks in the membranes or seals within the stack. In addition to the integrity testing, an itemized list and part cost estimate was produced for the components of the electrolyzer system. An evaluation of the system s present state and an estimate of the cost to bring it back to operational status was also produced.

  13. Evaluation of computer-aided detection and diagnosis systems.

    Science.gov (United States)

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in

  14. The ambiguities of performance-based governance reforms in Italy: Reviving the fortunes of evaluation and performance measurement.

    Science.gov (United States)

    Marra, Mita

    2018-08-01

    Over the past two decades, Italy's administrative reforms have institutionalized evaluation to improve program effectiveness, staff productivity, and results-driven accountability against waste and corruption. Across ministries, regional governments, universities, schools and environmental protection agencies, seemingly unexpected consequences have emerged out of the implementation of performance measurement and evaluation regimes within public organizations. Formal compliance to legally binding evaluation procedures, judicially-sanctioned managerial accountability and lack of cross-agency coordination coupled with long-standing cultural separations among evaluators are some of the ambiguities associated with a performance-based governance system within Italian public administration. Building upon the 'new governane theory,' and qualitative fieldwork, I explore the political consequences of evaluation and performance measurement for possible improvements. From a normative perspective, greater integration between program evaluation and performance measurement can support organizational learning and democratic accountability both at the central and local level. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Performance Evaluation Of Modified V-Blast In Mimo System

    Science.gov (United States)

    Suneetha, Ch.; Harathi, N.; Sudha, K.

    2012-03-01

    The MIMO system (multiple Antennas at the transmitter and receiver)is a capable of very high theoretical capacities, the most popular architecture is so called vertical VBLAST. VBLAST is an effective detection method for MIMO communication system, but has large computational complexity due its successive iteration . In this paper we used modified VBLAST to lessen its computational complexity reducing the number of successive iterations. As a result of this simplification, the computational complexity of the detection is lowered significantly. Simulation results show that the proposed V-BLAST reduces calculation complexity by about 30% while achieving a very close BER performance s the original one.

  16. Conceptual design of emergency communication system to cope with severe accidents in NPPs and its performance evaluation

    International Nuclear Information System (INIS)

    Son, Kwang Seop; Kim, Chang Hwoi; Kang, Hyun Gook

    2015-01-01

    Highlights: • The emergency communication system requires the performances of the throughput of 1 Mbps, BER of 10 −6 and network configuration of 1:12 communication. • The emergency communication system consists of the terrestrial communication and satellite communication system. • In the terrestrial communication system, at least two wireless repeaters are needed to secure LOS and the throughput and delay time are 16 Mbps and 16 ms, respectively. • In the satellite communication system, DSSS and FDMA are used and the fade margin range is from 1.3 to 16 dB. - Abstract: The Fukushima accident induced by the great earthquake and tsunami reveals the vulnerability of I and C System. In the severe environment, the normal I and C system did not work properly and results in false information about the internal situation in NPP. Eventually the accident was not properly handled at the early stage. Therefore advanced emergency response system using a wireless channel is necessary to cope with the severe accident. In this paper, we introduce the ERS consisting of the HMS and MCS the ECS linking the HMS with MCS and the performance requirement of the ECS is analyzed. The ECS satisfying the requirement is designed conceptually and the performance of the ECS is evaluated through analysis and simulator. To secure a reliable and diverse configuration, the ECS is configured as the dual system which consists of the terrestrial communication and satellite communication. The terrestrial communication system is designed based on the IEEE 802.11. Analyzed performance results prove that the performance requirement can be sufficiently achieved. But if the scalability of data capacity is considered later, use of the advanced 802.11 standard such as 802.11n and multiple signal paths between the HMS and MCS are necessary. In the satellite communication system, the FDMA is used in the status link and the DSSS is used in the control link. The network supporting various data rates is

  17. High-definition television evaluation for remote handling task performance

    International Nuclear Information System (INIS)

    Fujita, Y.; Omori, E.; Hayashi, S.; Draper, J.V.; Herndon, J.N.

    1986-01-01

    In a plant that employs remote handling techniques for equipment maintenance, operators perform maintenance tasks primarily by using the information from television systems. The efficiency of the television system has a significant impact on remote maintenance task performance. High-definition television (HDTV) transmits a video image with more than twice the number of horizontal scan lines as standard-resolution television (1125 for HDTV to 525 for standard-resolution NTSC television). The added scan lines dramatically improve the resolution of images on the HDTV monitors. This paper describes experiments designed to evaluate the impact of HDTV on the performance of typical remote tasks. The experiments described in this paper compared the performance of four operators using HDTV with their performance while using other television systems. The experiments included four television systems: (a) high-definition color television, (b) high-definition monochromatic television, (c) standard-resolution monochromatic television, and (d) standard-resolution stereoscopic monochromatic television

  18. Preliminary plan for disposal-system characterization and long-term performance evaluation of the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Bertram-Howery, S.G.; Hunter, R.L.

    1989-04-01

    The US Department of Energy is planning to dispose of transuranic wastes at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico. Sandia National Laboratories is responsible for evaluating the compliance of the WIPP with the Environmental Protection Agency's Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). This plan has been developed to present the issues that will be addressed before compliance can be evaluated. These issues examine the procedural nature of the Standard, and the technical requirements for further characterizing the behavior of the disposal system, including uncertainties, to support the compliance assessment. The plan briefly describes the activities that will be conducted prior to 1993 by Sandia to characterize the WIPP disposal system's behavior and predict its performance. 41 refs., 35 figs., 21 tabs

  19. 13 CFR 304.4 - Performance evaluations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Performance evaluations. 304.4... ECONOMIC DEVELOPMENT DISTRICTS § 304.4 Performance evaluations. (a) EDA shall evaluate the management... of at least one (1) other District Organization in the performance evaluation on a cost-reimbursement...

  20. New earth system model for optical performance evaluation of space instruments.

    Science.gov (United States)

    Ryu, Dongok; Kim, Sug-Whan; Breault, Robert P

    2017-03-06

    In this study, a new global earth system model is introduced for evaluating the optical performance of space instruments. Simultaneous imaging and spectroscopic results are provided using this global earth system model with fully resolved spatial, spectral, and temporal coverage of sub-models of the Earth. The sun sub-model is a Lambertian scattering sphere with a 6-h scale and 295 lines of solar spectral irradiance. The atmospheric sub-model has a 15-layer three-dimensional (3D) ellipsoid structure. The land sub-model uses spectral bidirectional reflectance distribution functions (BRDF) defined by a semi-empirical parametric kernel model. The ocean is modeled with the ocean spectral albedo after subtracting the total integrated scattering of the sun-glint scatter model. A hypothetical two-mirror Cassegrain telescope with a 300-mm-diameter aperture and 21.504 mm × 21.504-mm focal plane imaging instrument is designed. The simulated image results are compared with observational data from HRI-VIS measurements during the EPOXI mission for approximately 24 h from UTC Mar. 18, 2008. Next, the defocus mapping result and edge spread function (ESF) measuring result show that the distance between the primary and secondary mirror increases by 55.498 μm from the diffraction-limited condition. The shift of the focal plane is determined to be 5.813 mm shorter than that of the defocused focal plane, and this result is confirmed through the estimation of point spread function (PSF) measurements. This study shows that the earth system model combined with an instrument model is a powerful tool that can greatly help the development phase of instrument missions.

  1. Assessment of applicability of portable HPGe detector with in situ object counting system based on performance evaluation of thyroid radiobioassays

    Energy Technology Data Exchange (ETDEWEB)

    Park, Min Seok; Kwon, Tae Eun; Pak, Min Jung; Park, Se Young; Ha, Wi Ho; Jin, Young Woo [National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2017-06-15

    Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained 125I and 131I in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure 125I because of the limited energy resolution of the NaI(Tl) scintillator. The 131I results from both detectors agreed to within 5% with the certified results. Moreover, the 125I results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation

  2. Safety evaluation of BWR off-gas treatment systems

    International Nuclear Information System (INIS)

    Schultz, R.J.; Schmitt, R.C.

    1975-01-01

    Some of the results of a safety evaluation performed on current generic types of BWR off-gas treatment systems including cooled and ambient temperature adsorber beds and cryogenics are presented. The evaluation covered the four generic types of off-gas systems and the systems of five major vendors. This study was part of original work performed under AEC contract for the Directorate of Regulatory Standards. The analysis techniques employed for the safety evaluation of these systems include: Fault Tree Analysis; FMECA (Failure Mode Effects and Criticality Analysis); general system comparisons, contaminant, system control, and design adequacy evaluations; and resultant Off-Site Dose Calculations. The salient areas presented are some of the potential problem areas, the approach that industry has taken to mitigate or design against potential upset conditions, and areas where possible deficiencies still exist. Potential problem areas discussed include hydrogen detonation, hydrogen release to equipment areas, operator/automatic control interface, and needed engineering evaluation to insure safe system operation. Of the systems reviewed, most were in the category of advanced or improved over that commonly in use today, and a conclusion from the study was that these systems offer excellent potential for noble gas control for BWR power plants where more stringent controls may be specified -- now or in the future. (U.S.)

  3. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  4. Evaluation of the Quality of Occupational Health and Safety Management Systems Based on Key Performance Indicators in Certified Organizations

    OpenAIRE

    Iraj Mohammadfam; Mojtaba Kamalinia; Mansour Momeni; Rostam Golmohammadi; Yadollah Hamidi; Alireza Soltanian

    2017-01-01

    Background: Occupational Health and Safety Management Systems are becoming more widespread in organizations. Consequently, their effectiveness has become a core topic for researchers. This paper evaluates the performance of the Occupational Health and Safety Assessment Series 18001 specification in certified companies in Iran. Methods: The evaluation is based on a comparison of specific criteria and indictors related to occupational health and safety management practices in three certified...

  5. Assessing Performance of Botswana’s Public Hospital System: The Use of the World Health Organization Health System Performance Assessment Framework

    Directory of Open Access Journals (Sweden)

    Onalenna Seitio-Kgokgwe

    2014-09-01

    Full Text Available Background Very few studies have assessed performance of Botswana public hospitals. We draw from a large research study assessing performance of the Botswana Ministry of Health (MoH to evaluate the performance of public hospital system using the World Health Organization Health Systems Performance Assessment Framework (WHO HSPAF. We aimed to evaluate performance of Botswana public hospital system; relate findings of the assessment to the potential for improvements in hospital performance; and determine the usefulness of the WHO HSPAF in assessing performance of hospital systems in a developing country. Methods This article is based on data collected from document analysis, 54 key informants comprising senior managers and staff of the MoH (N= 40 and senior officers from stakeholder organizations (N= 14, and surveys of 42 hospital managers and 389 health workers. Data from documents and transcripts were analyzed using content and thematic analysis while data analysis for surveys was descriptive determining proportions and percentages. Results The organizational structure of the Botswana’s public hospital system, authority and decision-making are highly centralized. Overall physical access to health services is high. However, challenges in the distribution of facilities and inpatient beds create inequities and inefficiencies. Capacity of the hospitals to deliver services is limited by inadequate resources. There are significant challenges with the quality of care. Conclusion While Botswana invested considerably in building hospitals around the country resulting in high physical access to services, the organization and governance of the hospital system, and inadequate resources limit service delivery. The ongoing efforts to decentralize management of hospitals to district level entities should be expedited. The WHO HSPAF enabled us to conduct a comprehensive assessment of the public hospital system. Though relatively new, this approach proved

  6. Performance evaluation of the reference system for calibration of IPEN activities

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Elaine Wirney; Potiens, Maria da Penha A., E-mail: ewmartins@ipen.br, E-mail: mppalbu@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The formation of good quality image in nuclear medicine services depends on several factors, including the radiopharmaceutical activity, which must be well determined by a specific apparatus, in perfect operating condition, called activimeter. Therefore, the establishment of a quality control program for measuring the radiopharmaceuticals radioactivity before being administered to the patient is crucial to the safe and effective use of the radiopharmaceuticals used in diagnostic and therapeutical procedures. Two activimeters, belonging by the Laboratorio de Calibracao do Instrumentos (LCI) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), were evaluated: the secondary standard system NPL-CRC radionuclide calibrator, manufactured by Southern Scientific, and the work standard system CRC-15BT with traceability to National Institute of Standard and Technology (NIST). A set of standard sources of the radionuclides {sup 1}'3{sup 3}Ba, {sup 57}Co and {sup 137}Cs was used as reference to perform the quality control tests. The precision, accuracy and repeatability tests were in agreement with those established by the CNEN-NE 3.05 Brazilian standard, which recommends the variation limit of up to 10%, 5% and 5% respectively. The results obtained for the reproducibility tests presented a variation always below 1,5%, which means it is within the IEC 61674 international standard recommendation of up to 3%. Activimeters response regarding linearity showed concordance between the measured activities and the theoretical curve for both activimeters. (author)

  7. Performance Evaluation of a Demonstration System with PCM for Seasonal Heat Storage: Charge with Evacuated Tubular Collectors

    DEFF Research Database (Denmark)

    Englmair, Gerald; Furbo, Simon; Kong, Weiqiang

    with sunshine, the storage system performance was evaluated regarding charge with solar heat. It shows the system behavior during typical operation resulting from the control strategy. Heat transfer rates from the solar collector array (22.4 m2 aperture area) to the heat stores reached a peak of 19 kW, when PCM......A seasonal heat storage with phase change material (PCM) for a solar space heating and domestic hot water combisystem was tested in automated operation during charge with solar collectors. A water tank was operating as buffer heat storage. Based on measurements during a representative day...... temperatures were increasing with the state of charge. This is in contrast to maximization of solar yield. However, the energy conversion efficiency (65 %) of the collector array was satisfying. By considering pump electricity consumption, an overall performance ratio of 30.8 was obtained....

  8. Metrics for Performance Evaluation of Patient Exercises during Physical Therapy.

    Science.gov (United States)

    Vakanski, Aleksandar; Ferguson, Jake M; Lee, Stephen

    2017-06-01

    The article proposes a set of metrics for evaluation of patient performance in physical therapy exercises. Taxonomy is employed that classifies the metrics into quantitative and qualitative categories, based on the level of abstraction of the captured motion sequences. Further, the quantitative metrics are classified into model-less and model-based metrics, in reference to whether the evaluation employs the raw measurements of patient performed motions, or whether the evaluation is based on a mathematical model of the motions. The reviewed metrics include root-mean square distance, Kullback Leibler divergence, log-likelihood, heuristic consistency, Fugl-Meyer Assessment, and similar. The metrics are evaluated for a set of five human motions captured with a Kinect sensor. The metrics can potentially be integrated into a system that employs machine learning for modelling and assessment of the consistency of patient performance in home-based therapy setting. Automated performance evaluation can overcome the inherent subjectivity in human performed therapy assessment, and it can increase the adherence to prescribed therapy plans, and reduce healthcare costs.

  9. Development of performance tests for an automated MC and A system

    International Nuclear Information System (INIS)

    Kok, K.D.; Klingensmith, R.W.; Riffle, W.; Carver, R.D.; Schumacher, S.S.; Lavender, J.C.; Smith, B.W.

    1988-01-01

    Performance tests of MC and A systems using computers are described, and some example scenarios are discussed. Facility personnel or an external inspection group may use performance tests to evaluate MC and A capabilities under actual operating conditions. This paper addresses test elements common to both user groups. Performance tests consist of scenario development, security, and safety measures, conduct, and evaluation. Because exercises often test scenarios against which the MC and A system is protecting, they may require additional security and safety measures. Computer systems enhance MC and A by providing greater speed, increased precision, and automated checks. Performance tests for MC and A systems using computers differ from performance tests employing manual data systems in that the scenarios must anticipate computer actions rather than utilize controllers to adjust the scenario

  10. Signal and image processing systems performance evaluation, simulation, and modeling; Proceedings of the Meeting, Orlando, FL, Apr. 4, 5, 1991

    Science.gov (United States)

    Nasr, Hatem N.; Bazakos, Michael E.

    The various aspects of the evaluation and modeling problems in algorithms, sensors, and systems are addressed. Consideration is given to a generic modular imaging IR signal processor, real-time architecture based on the image-processing module family, application of the Proto Ware simulation testbed to the design and evaluation of advanced avionics, development of a fire-and-forget imaging infrared seeker missile simulation, an adaptive morphological filter for image processing, laboratory development of a nonlinear optical tracking filter, a dynamic end-to-end model testbed for IR detection algorithms, wind tunnel model aircraft attitude and motion analysis, an information-theoretic approach to optimal quantization, parametric analysis of target/decoy performance, neural networks for automated target recognition parameters adaptation, performance evaluation of a texture-based segmentation algorithm, evaluation of image tracker algorithms, and multisensor fusion methodologies. (No individual items are abstracted in this volume)

  11. Performance evaluation of the Trans-PET®BioCaliburn® SH system

    Science.gov (United States)

    Zhu, Jun; Wang, Luyao; Kao, Chien-Min; Kim, Heejong; Xie, Qingguo

    2015-03-01

    The Trans-PET®BioCaliburn® SH system, recently introduced by the Raycan Technology Co. Ltd. (Suzhou, China), is a commercial positron emission tomography (PET) system designed for rodent imaging. The system contains 6 basic detector modules (BDMs) arranged on a 10.8 cm diameter ring to provide a transaxial field of view (FOV) of 6.5 cm and an axial FOV of 5.3 cm. In this paper, we report on its performance properties in accordance with the National Electrical Manufacturers Association (NEMA) 2008 NU-4 standards with modifications. The measured spatial resolution at the center of the FOV was 1.05 mm, 1.12 mm and 1.13 mm in the tangential, radial and axial directions, respectively. The measured system sensitivity was 3.29% for a point source at the center of the FOV when using a 350-650 keV energy window and a 5 ns coincidence time window. When a wider 250-750 keV energy window was used, it increased to 4.21%. For mouse- and rat-sized phantoms, the scatter fraction was 10.7% and 16.1%, respectively. The peak noise equivalent count rate were 36 kcps@8.52 MBq for the mouse-sized phantom and 16 kcps@6.79 MBq for the rat-sized phantom. The Derenzo phantom image showed that the system can resolve 1.0 mm diameter rods. The measured performance properties of the system indicate that the Trans-PET®BioCaliburn® SH is a versatile imaging device that can provide high spatial resolution for rodent imaging while offering competitive sensitivity and count-rate performance.

  12. Performance Evaluation of Supercomputers using HPCC and IMB Benchmarks

    Science.gov (United States)

    Saini, Subhash; Ciotti, Robert; Gunney, Brian T. N.; Spelce, Thomas E.; Koniges, Alice; Dossa, Don; Adamidis, Panagiotis; Rabenseifner, Rolf; Tiyyagura, Sunil R.; Mueller, Matthias; hide

    2006-01-01

    The HPC Challenge (HPCC) benchmark suite and the Intel MPI Benchmark (IMB) are used to compare and evaluate the combined performance of processor, memory subsystem and interconnect fabric of five leading supercomputers - SGI Altix BX2, Cray XI, Cray Opteron Cluster, Dell Xeon cluster, and NEC SX-8. These five systems use five different networks (SGI NUMALINK4, Cray network, Myrinet, InfiniBand, and NEC IXS). The complete set of HPCC benchmarks are run on each of these systems. Additionally, we present Intel MPI Benchmarks (IMB) results to study the performance of 11 MPI communication functions on these systems.

  13. A study on the performance evaluation of small gamma camera collimators using detective quantun efficiency

    International Nuclear Information System (INIS)

    Jeon, Ho Sang

    2008-02-01

    The anger-type gamma camera and novel marker compound using Tc-99m were firstly introduced in 1963. The gamma camera systems have being improved and applied to various fields, for example, medical, industrial, and environmental fields. Gamma camera is mainly composed of collimator, detector, and signal processor. And the radiative source is namely the imaging object. The collimator is essential component of gamma camera system because the imaging performance of system is mainly dependent on the collimator. The performance evaluation of collimators can be done by using evaluating factors. In this study, the novel factors for gamma camera evaluation are suggested. The established evaluating factors by NEMA are FWHM, sensitivity, and uniformity. They have some limitations in spite of their usefulness. Firstly, performance evaluation by those factors give insensitive and indirect results only. Secondly, the evaluation of noise property is ambiguous. Thirdly, there is no synthetic evaluation of system performance. Simulation with Monte Carlo code and experiment with a small camera camera were simultaenuously performed to verify novel evaluating factors. For the evaluation of spatial resolution, MTF was applied instead of FWHM. The MTF values presents excellent linear relationship with FWHM values. The NNPS was applied instead of uniformity and sensitivity for the evaluation of noise fluctuation. The NNPS values also presents linear relationship with sensitivity and unifomity. Moreover, these novel factors give quantities as the function of spatial frequencies. Finally, the DQE values were given by calculations with MTF, NNPS, and input SNR. DQE effectively presents the synthetic evaluation of gamma camera performance. It is the conclusion that MTF, NNPS, and DQE can be novel evaluating factors for gamma camera systems and the new factor for synthetic evaluation is derived

  14. A model for evaluating the social performance of construction waste management.

    Science.gov (United States)

    Yuan, Hongping

    2012-06-01

    It has been determined by existing literature that a lot of research efforts have been made to the economic performance of construction waste management (CWM), but less attention is paid to investigation of the social performance of CWM. This study therefore attempts to develop a model for quantitatively evaluating the social performance of CWM by using a system dynamics (SD) approach. Firstly, major variables affecting the social performance of CWM are identified and a holistic system for assessing the social performance of CWM is formulated in line with feedback relationships underlying these variables. The developed system is then converted into a SD model through the software iThink. An empirical case study is finally conducted to demonstrate application of the model. Results of model validation indicate that the model is robust and reasonable to reflect the situation of the real system under study. Findings of the case study offer helpful insights into effectively promoting the social performance of CWM of the project investigated. Furthermore, the model exhibits great potential to function as an experimental platform for dynamically evaluating effects of management measures on improving the social performance of CWM of construction projects. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Performance Evaluation and Parameter Identification on DROID III

    Science.gov (United States)

    Plumb, Julianna J.

    2011-01-01

    The DROID III project consisted of two main parts. The former, performance evaluation, focused on the performance characteristics of the aircraft such as lift to drag ratio, thrust required for level flight, and rate of climb. The latter, parameter identification, focused on finding the aerodynamic coefficients for the aircraft using a system that creates a mathematical model to match the flight data of doublet maneuvers and the aircraft s response. Both portions of the project called for flight testing and that data is now available on account of this project. The conclusion of the project is that the performance evaluation data is well-within desired standards but could be improved with a thrust model, and that parameter identification is still in need of more data processing but seems to produce reasonable results thus far.

  16. Performance validation of commercially available mobile waste-assay systems: Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Schanfein, M.; Bonner, C.; Maez, R. [Los Alamos National Lab., NM (United States)] [and others

    1997-11-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content to reduce the radioactive hazard to the public. Validation of the waste-assay systems` performance is critical for establishing the credibility of the assay results for storage and disposal purposes. Canberra Nuclear has evaluated regulations worldwide and identified standard, modular, neutron- and gamma-waste-assay systems that can be used to characterize a large portion of existing and newly generated transuranic (TRU) and low-level waste. Before making claims of guaranteeing any system`s performance for specific waste types, the standardized systems` performance be evaluated. 7 figs., 11 tabs.

  17. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  18. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  19. Performance evaluation of stand alone hybrid PV-wind generator

    International Nuclear Information System (INIS)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-01-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand

  20. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  1. Performance evaluation and financial market runs

    NARCIS (Netherlands)

    Wagner, W.B.

    2013-01-01

    This paper develops a model in which performance evaluation causes runs by fund managers and results in asset fire sales. Performance evaluation nonetheless is efficient as it disciplines managers. Optimal performance evaluation combines absolute and relative components in order to make runs less

  2. Performance Evaluations in Audit Firms

    DEFF Research Database (Denmark)

    Riise Johansen, Thomas; Christoffersen, Jeppe

    2017-01-01

    Previous research has only minimally examined the association between the behaviour and performance evaluations of individual auditors beyond the use of efficiency-focused evaluations. We examine the association between dysfunctional auditor behaviour and three evaluation foci: an efficiency focus......, a client focus and a quality focus. Our results, which are based on questionnaire responses from 196 auditors, demonstrate that an efficiency focus is not associated with dysfunctional behaviour. A client focus is found to be associated with dysfunctional behaviour. Finally, and perhaps most importantly......, our results show that it seems possible to limit dysfunctional behaviours through a quality focus in performance evaluations. Our results provide insights of use to practitioners and regulators on how performance evaluations may not only induce but also reduce dysfunctional auditor behaviours....

  3. Data Envelopment Analysis as a Tool for Evaluation of Employees Performance

    Directory of Open Access Journals (Sweden)

    ZBRANEK

    2013-02-01

    Full Text Available Employee performance evaluation systems, which are well designed and properly used, are essential for the effective functioning of the organization. Due to some disadvantages of traditional methods, there is a need to develop new evaluation procedures. The main contribution of this paper is to apply a multidimensional approach, represented by the method of Data Envelopment Analysis (DEA to measure the performance and efficiency of employees. This approach overcomes several weaknesses of traditional systems of the employees’ performance evaluation and provides a comprehensive indicator of the performance of individual employees, their technical efficiency score. The input variables of the used model were the motivational factors (salary, working conditions and benefits; the output was the indirectly assessed performance through work motivation, job satisfaction and organizational commitment. Furthermore, we applied the nonparametric methods for compliance testing of mean values to validate the stated hypotheses. In a baking company using the DEA method, we identified 12 efficient employees and 48 employees who need to improve their outputs to achieve their maximum efficiency.

  4. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  5. A numerical study on the performance evaluation of ventilation systems for indoor radon reduction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Eun; Park, Hoon Chae; Choi, Hang Seok; Cho, Seung Yeon; Jeong, Tae Young; Roh, Sung Cheoul [Yonsei University, Wonju (Korea, Republic of)

    2016-03-15

    Numerical simulations were conducted using computational fluid dynamics to evaluate the effect of ventilation conditions on radon ({sup 222}Rn) reduction performance in a residential building. The results indicate that at the same ventilation rate, a mechanical ventilation system is more effective in reducing indoor radon than a natural ventilation system. For the same ventilation type, the indoor radon concentration decreases as the ventilation rate increases. When the air change per hour (ACH) was 1, the indoor radon concentration was maintained at less than 100 Bq/m{sup 3}. However, when the ACH was lowered to 0.01, the average indoor radon concentration in several rooms exceeded 148 Bq/ m{sup 3}. The angle of the inflow air was found to affect the indoor air stream and consequently the distribution of the radon concentration. Even when the ACH was 1, the radon concentrations of some areas were higher than 100 Bq/m{sup 3} for inflow air angles of 5 .deg. and 175 .deg.

  6. Performance measurement system for training simulators. Interim report

    International Nuclear Information System (INIS)

    Bockhold, G. Jr.; Roth, D.R.

    1978-05-01

    In the first project phase, the project team has designed, installed, and test run on the Browns Ferry nuclear power plant training simulator a performance measurement system capable of automatic recording of statistical information on operator actions and plant response. Key plant variables and operator actions were monitored and analyzed by the simulator computer for a selected set of four operating and casualty drills. The project has the following objectives: (1) To provide an empirical data base for statistical analysis of operator reliability and for allocation of safety and control functions between operators and automated controls; (2) To develop a method for evaluation of the effectiveness of control room designs and operating procedures; and (3) To develop a system for scoring aspects of operator performance to assist in training evaluations and to support operator selection research. The performance measurement system has shown potential for meeting the research objectives. However, the cost of training simulator time is high; to keep research program costs reasonable, the measurement system is being designed to be an integral part of operator training programs. In the pilot implementation, participating instructors judged the measurement system to be a valuable and objective extension of their abilities to monitor trainee performance

  7. Performance Evaluation of Photovoltaic Solar Air Conditioning

    Directory of Open Access Journals (Sweden)

    Snegirjovs A.

    2016-12-01

    Full Text Available Information on the electrical-driven solar air conditioning (SAC is rather scanty. A considerable body of technical data mostly concerns large-scale photo-voltaic solar air conditioning (PV-SAC systems. Reliable information about the energy output has arisen only in recent years; however, it is still not easily accessible, and sometimes its sources are closed. Despite these facts, solar energy researchers, observers and designers devote special attention to this type of SAC systems. In this study, performance evaluation is performed for the PV-SAC technology, in which low-power (up to 15 kWp of cooling power on average systems are used. Such a system contains a PV electric-driven compression chiller with cold and heat sensible thermal storage capacities, and a rejected energy unit used for preheating domestic hot water (DHW. In a non-cooling season, it is possible to partly employ the system in the reverse mode for DHW production. In this mode, the ambient air serves as a heat source. Besides, free cooling is integrated in the PV-SAC concept.

  8. Performance Evaluation of Photovoltaic Solar Air Conditioning

    Science.gov (United States)

    Snegirjovs, A.; Shipkovs, P.; Lebedeva, K.; Kashkarova, G.; Migla, L.; Gantenbein, P.; Omlin, L.

    2016-12-01

    Information on the electrical-driven solar air conditioning (SAC) is rather scanty. A considerable body of technical data mostly concerns large-scale photo-voltaic solar air conditioning (PV-SAC) systems. Reliable information about the energy output has arisen only in recent years; however, it is still not easily accessible, and sometimes its sources are closed. Despite these facts, solar energy researchers, observers and designers devote special attention to this type of SAC systems. In this study, performance evaluation is performed for the PV-SAC technology, in which low-power (up to 15 kWp of cooling power on average) systems are used. Such a system contains a PV electric-driven compression chiller with cold and heat sensible thermal storage capacities, and a rejected energy unit used for preheating domestic hot water (DHW). In a non-cooling season, it is possible to partly employ the system in the reverse mode for DHW production. In this mode, the ambient air serves as a heat source. Besides, free cooling is integrated in the PV-SAC concept.

  9. High-definition television evaluation for remote handling task performance

    International Nuclear Information System (INIS)

    Fujita, Y.; Omori, E.; Hayashi, S.; Draper, J.V.; Herndon, J.N.

    1986-01-01

    This paper describes experiments designed to evaluate the impact of HDTV on the performance of typical remote tasks. The experiments described in this paper compared the performance of four operators using HDTV with their performance while using other television systems. The experiments included four television systems: (1) high-definition color television, (2) high-definition monochromatic television, (3) standard-resolution monochromatic television, and (4) standard-resolution stereoscopic monochromatic television. The stereo system accomplished stereoscopy by displaying two cross-polarized images, one reflected by a half-silvered mirror and one seen through the mirror. Observers wore a pair of glasses with cross-polarized lenses so that the left eye received only the view from the left camera and the right eye received only the view from the right camera

  10. Integrated system for seismic evaluations

    International Nuclear Information System (INIS)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01

    This paper describes the various features of the Seismic Module of the CARES system (Computer Analysis for Rapid Evaluation of Structures). This system was developed by Brookhaven National Laboratory (BNL) for the US Nuclear Regulatory Commission to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structured in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the Seismic Module in particular. The development of the Seismic Module of the CARES system is based on an approach which incorporates all major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities. It has been designed with user friendly features and it allows for interactive manipulation of various analysis phases during the seismic design process. The capabilities of the seismic module include (a) generation of artificial time histories compatible with given design ground response spectra, (b) development of Power Spectral Density (PSD) functions associated with the seismic input, (c) deconvolution analysis using vertically propagating shear waves through a given soil profile, and (d) development of in-structure response spectra or corresponding PSD's. It should be pointed out that these types of analyses can also be performed individually by using available computer codes such as FLUSH, SAP, etc. The uniqueness of the CARES, however, lies on its ability to perform all required phases of the seismic analysis in an integrated manner. 5 refs., 6 figs

  11. Using simulation to evaluate the performance of resilience strategies and process failures

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Scott N.; Topp, Bryan Embry; Arnold, Dorian C; Ferreira, Kurt Brian; Widener, Patrick; Hoefler, Torsten

    2014-01-01

    Fault-tolerance has been identified as a major challenge for future extreme-scale systems. Current predictions suggest that, as systems grow in size, failures will occur more frequently. Because increases in failure frequency reduce the performance and scalability of these systems, significant effort has been devoted to developing and refining resilience mechanisms to mitigate the impact of failures. However, effective evaluation of these mechanisms has been challenging. Current systems are smaller and have significantly different architectural features (e.g., interconnect, persistent storage) than we expect to see in next-generation systems. To overcome these challenges, we propose the use of simulation. Simulation has been shown to be an effective tool for investigating performance characteristics of applications on future systems. In this work, we: identify the set of system characteristics that are necessary for accurate performance prediction of resilience mechanisms for HPC systems and applications; demonstrate how these system characteristics can be incorporated into an existing large-scale simulator; and evaluate the predictive performance of our modified simulator. We also describe how we were able to optimize the simulator for large temporal and spatial scales-allowing the simulator to run 4x faster and use over 100x less memory.

  12. Performance of arthroscopic irrigation systems assessed with automatic blood detection

    NARCIS (Netherlands)

    Tuijthof, G. J. M.; de Vaal, M. M.; Sierevelt, I. N.; Blankevoort, L.; van der List, M. P. J.

    2011-01-01

    During arthroscopies, bleeding episodes occur as a result of tissue damage. Irrigation systems assist in minimizing these disturbances. The performance of three arthroscopic irrigation systems in clearing bleeding episodes was evaluated objectively. One surgeon performed 99 shoulder arthroscopies

  13. Total-System Performance Assessment for the Yucca Mountain Site

    International Nuclear Information System (INIS)

    Wilson, M.L.

    2001-01-01

    Yucca Mountain, Nevada, is under consideration as a potential site for a repository for high-level radioactive waste. Total-system performance-assessment simulations are performed to evaluate the safety of the site. Features, events, and processes have been systematically evaluated to determine which ones are significant to the safety assessment. Computer models of the disposal system have been developed within a probabilistic framework, including both engineered and natural components. Selected results are presented for three different total-system simulations, and the behavior of the disposal system is discussed. The results show that risk is dominated by igneous activity at early times, because the robust waste-package design prevents significant nominal (non-disruptive) releases for tens of thousands of years or longer. The uncertainty in the nominal performance is dominated by uncertainties related to waste-package corrosion at early times and by uncertainties in the natural system, most significantly infiltration, at late times

  14. Performance Evaluation of Engineered Structured Sorbents for Atmosphere Revitalization Systems On Board Crewed Space Vehicles and Habitats

    Science.gov (United States)

    Howard, David F.; Perry, Jay L.; Knox, James C.; Junaedi, Christian; Roychoudhury, Subir

    2011-01-01

    Engineered structured (ES) sorbents are being developed to meet the technical challenges of future crewed space exploration missions. ES sorbents offer the inherent performance and safety attributes of zeolite and other physical adsorbents but with greater structural integrity and process control to improve durability and efficiency over packed beds. ES sorbent techniques that are explored include thermally linked and pressure-swing adsorption beds for water-save dehumidification and sorbent-coated metal meshes for residual drying, trace contaminant control, and carbon dioxide control. Results from sub-scale performance evaluations of a thermally linked pressure-swing adsorbent bed and an integrated sub-scale ES sorbent system are discussed.

  15. Total System Performance Assessment, 1993: An evaluation of the potential Yucca Mountain repository, B00000000-01717-2200-00099, Rev. 01

    International Nuclear Information System (INIS)

    Andrews, R.W.; Dale, T.F.; McNeish, J.A.

    1994-03-01

    Total System Performance Assessments are an important component in the evaluation of the suitability of Yucca Mountain, Nevada as a potential site for a mined geologic repository for the permanent disposal of high-level radioactive wastes in the United States. The Total System Performance Assessments are conducted iteratively during the site characterization to identify issues which should be addressed by the characterization and design activities as well as providing input to regulatory/licensing and programmatic decisions. During fiscal years 1991 and 1992, the first iteration of Total System Performance Assessment (hereafter referred to as TSPA 1991) was completed by Sandia National Laboratories and Pacific Northwest Laboratory. Beginning in fiscal year 1993, the Civilian Radioactive Waste Management System Management and Operating Contractor was assigned the responsibility to plan, coordinate, and contribute to the second iteration of Total System Performance Assessment (hereafter referred to as TSPA 1993). This document presents the objectives, approach, assumptions, input, results, conclusions, and recommendations associated with the Management and Operating Contractor contribution to TSPA 1993. A parallel effort was conducted by Sandia National Laboratories and is reported in Wilson et al. (1994, in press)

  16. Evaluation of the Terminal Area Precision Scheduling and Spacing System for Performance-Based Navigation Arrivals

    Science.gov (United States)

    Jung, Jaewoo; Swenson, Harry; Thipphavong, Jane; Martin, Lynne Hazel; Chen, Liang; Nguyen, Jimmy

    2013-01-01

    The growth of global demand for air transportation has put increasing strain on the nation's air traffic management system. To relieve this strain, the International Civil Aviation Organization has urged all nations to adopt Performance-Based Navigation (PBN), which can help to reduce air traffic congestion, decrease aviation fuel consumption, and protect the environment. NASA has developed a Terminal Area Precision Scheduling and Spacing (TAPSS) system that can support increased use of PBN during periods of high traffic, while supporting fuel-efficient, continuous descent approaches. In the original development of this system, arrival aircraft are assigned fuel-efficient Area Navigation (RNAV) Standard Terminal Arrival Routes before their initial descent from cruise, with routing defined to a specific runway. The system also determines precise schedules for these aircraft that facilitate continuous descent through the assigned routes. To meet these schedules, controllers are given a set of advisory tools to precisely control aircraft. The TAPSS system has been evaluated in a series of human-in-the-loop (HITL) air traffic simulations during 2010 and 2011. Results indicated increased airport arrival throughput up to 10 over current operations, and maintained fuel-efficient aircraft decent profiles from the initial descent to landing with reduced controller workload. This paper focuses on results from a joint NASA and FAA HITL simulation conducted in 2012. Due to the FAA rollout of the advance terminal area PBN procedures at mid-sized airports first, the TAPSS system was modified to manage arrival aircraft as they entered Terminal Radar Approach Control (TRACON). Dallas-Love Field airport (DAL) was selected by the FAA as a representative mid-sized airport within a constrained TRACON airspace due to the close proximity of a major airport, in this case Dallas-Ft Worth International Airport, one of the busiest in the world. To address this constraint, RNAV routes and

  17. The performance of energy efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G.

    1996-08-01

    The adequacy and durability of residential building envelope systems under actual field conditions were evaluated. A building envelope offers protection from cold, heat, moisture, wind and noise. However, they are exposed to thermal, structural, and moisture stresses and their performance can degrade over time. Envelope performance was evaluated at 20 energy efficient and four conventional, detached modern homes in Winnipeg, Canada. The three complementary measurement tools were wood moisture content (WMC) of framing members, thermographic examinations, and airtightness tests. As expected, energy efficient building envelope systems performed better than the conventional systems. No evidence of envelope degradation was found in any of the energy efficient houses. The building envelopes using polyethylene air barriers performed slightly better than those which used the airtight drywall approach, although both were considered satisfactory. WMC levels were a bit lower in the polyethylene-clad house. 1 ref., 1 tab.

  18. Ensuring system security through formal software evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howell, J A; Fuyat, C [Los Alamos National Lab., NM (United States); Elvy, M [Marble Associates, Boston, MA (United States)

    1992-01-01

    With the increasing use of computer systems and networks to process safeguards information in nuclear facilities, the issue of system and data integrity is receiving worldwide attention. Among the many considerations are validation that the software performs as intended and that the information is adequately protected. Such validations are often requested of the Safeguards Systems Group of the Los Alamos National Laboratory. This paper describes our methodology for performing these software evaluations.

  19. Integrated modeling tool for performance engineering of complex computer systems

    Science.gov (United States)

    Wright, Gary; Ball, Duane; Hoyt, Susan; Steele, Oscar

    1989-01-01

    This report summarizes Advanced System Technologies' accomplishments on the Phase 2 SBIR contract NAS7-995. The technical objectives of the report are: (1) to develop an evaluation version of a graphical, integrated modeling language according to the specification resulting from the Phase 2 research; and (2) to determine the degree to which the language meets its objectives by evaluating ease of use, utility of two sets of performance predictions, and the power of the language constructs. The technical approach followed to meet these objectives was to design, develop, and test an evaluation prototype of a graphical, performance prediction tool. The utility of the prototype was then evaluated by applying it to a variety of test cases found in the literature and in AST case histories. Numerous models were constructed and successfully tested. The major conclusion of this Phase 2 SBIR research and development effort is that complex, real-time computer systems can be specified in a non-procedural manner using combinations of icons, windows, menus, and dialogs. Such a specification technique provides an interface that system designers and architects find natural and easy to use. In addition, PEDESTAL's multiview approach provides system engineers with the capability to perform the trade-offs necessary to produce a design that meets timing performance requirements. Sample system designs analyzed during the development effort showed that models could be constructed in a fraction of the time required by non-visual system design capture tools.

  20. A study of methodology and its applications for the evaluation of total system performance which considered the site-information and the design-information

    International Nuclear Information System (INIS)

    Inagaki, Manabu; Ebina, Takanori

    2008-01-01

    The step-by-step approach which chooses detailed investigation area(s) from the preliminary investigations area(s) in the volunteer sites is adopted on the high-level radioactive waste disposal in JAPAN. It's requested at the stage of chooses detailed investigation area that there are few fears that surf zone and groundwater stream exert bad influence on disposal facility as well as stability of the geological environment. In order to evaluate influence of groundwater stream, it is necessary to evaluate of total performance of disposal system with limited information from preliminary investigations and several design options which have been assumed on the generic geological environment. For a rational procedure of total system evaluation, it is essential to arrange of known information of the former performance evaluation, and so, when same part of those information was changed, we become able to pick a scenario, models, parameters with a possibility which changes out by tracing these information. In this study, as a first step, we carried out make a methodology to structure a flow of a series of information from a geological survey result in detail and until performance evaluation. We tried to make a structuralization of known information by base on this methodology. And, we discussed realistic performance of over-pack by tracing this structured information. (author)

  1. A model for evaluating the social performance of construction waste management

    International Nuclear Information System (INIS)

    Yuan Hongping

    2012-01-01

    Highlights: ► Scant attention is paid to social performance of construction waste management (CWM). ► We develop a model for assessing the social performance of CWM. ► With the model, the social performance of CWM can be quantitatively simulated. - Abstract: It has been determined by existing literature that a lot of research efforts have been made to the economic performance of construction waste management (CWM), but less attention is paid to investigation of the social performance of CWM. This study therefore attempts to develop a model for quantitatively evaluating the social performance of CWM by using a system dynamics (SD) approach. Firstly, major variables affecting the social performance of CWM are identified and a holistic system for assessing the social performance of CWM is formulated in line with feedback relationships underlying these variables. The developed system is then converted into a SD model through the software iThink. An empirical case study is finally conducted to demonstrate application of the model. Results of model validation indicate that the model is robust and reasonable to reflect the situation of the real system under study. Findings of the case study offer helpful insights into effectively promoting the social performance of CWM of the project investigated. Furthermore, the model exhibits great potential to function as an experimental platform for dynamically evaluating effects of management measures on improving the social performance of CWM of construction projects.

  2. Management Control Systems, Evaluative Style, and Behaviour : Exploring the Concept and Behavioural Consequences of Evaluative Style

    NARCIS (Netherlands)

    J. Noeverman (Jan)

    2007-01-01

    textabstractOrganisations develop and implement performance measurement and performance evaluation systems to motivate employees to take actions that -in the end- improve organisational (financial) performance. But do these systems really influence employee behaviour as intended? This thesis shows

  3. Performance evaluation of solar heating system with thermal core type soil heat storage. Part 5. Performance prediction and evaluation of the system considered of the weather condition; Taiyonetsu riyo netsu kakushiki dojo chikunetsu system no seino hyoka. 5. Kisho joken wo koryoshita system no seino yosoku to hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, N [Nishimatsu Construction Co. Ltd., Tokyo (Japan); Nakajima, Y [Kogakuin University, Tokyo (Japan)

    1997-11-25

    The paper studied a solar heating system with thermal core type soil heat storage (combining a thermal core composing of a water tank and an underground pebble tank and the soil around the heat storage tank and also using solar energy). Solar energy is stored by temperature level in the high temperature water tank, the low temperature pebble heat storage tank and the soil around the heat storage tank. Heat is recovered according to temperature as direct ventilation space heating (utilization of pebble tank air), floor heating (utilization of hot water of the heat storage water tank) and heat pump heat source (utilization of pebble tank air). A study was made of performance and regional effectiveness of the system under different weather conditions. A study was also made of effects of the water tank for short term heat storage by changing the water volume. Using the same structure, etc. for the system, the system was evaluated using weather data of Sapporo, Tokyo and Kagoshima. In terms of efficiency of the system, the system structure was found to be most suitable for weather conditions in Tokyo. However, the air heat source heat pump which cannot be usually used in the cold area has come to be used. Such effect except efficiency is also considered, and the amount of performance to be targeted in each region changes. 2 refs., 14 figs., 1 tab.

  4. The Blame Game: Performance Analysis of Speaker Diarization System Components

    NARCIS (Netherlands)

    Huijbregts, M.A.H.; Wooters, Chuck

    2007-01-01

    In this paper we discuss the performance analysis of a speaker diarization system similar to the system that was submitted by ICSI at the NIST RT06s evaluation benchmark. The analysis that is based on a series of oracle experiments, provides a good understanding of the performance of each system

  5. Barrier performance researches for the safety evaluation

    International Nuclear Information System (INIS)

    Niibori, Yuichi

    2004-01-01

    So far, many researches were conducted to propose a scientific evidence (a safety case) for the realization of geological disposal in Japan. In order to regulate the geological disposal system of radioactive wastes, on the other hand, we need also a holistic approach to integrate various data related for the performance evaluations of the engineered barrier system and the natural barrier system. However, the scientific bases are not sufficient to establish the safety regulation for such a natural system. For example, we often apply the specific probability density function (PDF) to the uncertainty of barrier system due to the essential heterogeneity. However, the applicability is not clear in the regulation point of view. A viewpoint to understand such an applicability of PDFs has been presented. (author)

  6. Thermodynamic performance assessment of wind energy systems: An application

    International Nuclear Information System (INIS)

    Redha, Adel Mohammed; Dincer, Ibrahim; Gadalla, Mohamed

    2011-01-01

    In this paper, the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. The thermodynamic characteristics of wind through energy and exergy analyses are considered and both energetic and exergetic efficiencies are studied. Wind speed is affected by air temperature and pressure and has a subsequent effect on wind turbine performance based on wind reference temperature and Bernoulli's equation. VESTAS V52 wind turbine is selected for (Sharjah/UAE). Energy and exergy efficiency equations for wind energy systems are further developed for practical applications. The results show that there are noticeable differences between energy and exergy efficiencies and that exergetic efficiency reflects the right/actual performance. Finally, exergy analysis has been proven to be the right tool used in design, simulation, and performance evaluation of all renewable energy systems. -- Highlights: → In this research the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. → Energy and exergy equations for wind energy systems are further developed for practical applications. → Thermodynamic characteristics of wind turbine systems through energetic and exergetic efficiencies are evaluated from January till March 2010. → Exergy efficiency describes the system irreversibility and the minimum irreversibility exists when the wind speed reaches 11 m/s. → The power production during March was about 17% higher than the month of February and 66% higher than January.

  7. Integrated DEA Models and Grey System Theory to Evaluate Past-to-Future Performance: A Case of Indian Electricity Industry

    Science.gov (United States)

    Wang, Chia-Nan; Tran, Thanh-Tuyen

    2015-01-01

    The growth of economy and population together with the higher demand in energy has created many concerns for the Indian electricity industry whose capacity is at 211 gigawatts mostly in coal-fired plants. Due to insufficient fuel supply, India suffers from a shortage of electricity generation, leading to rolling blackouts; thus, performance evaluation and ranking the industry turn into significant issues. By this study, we expect to evaluate the rankings of these companies under control of the Ministry of Power. Also, this research would like to test if there are any significant differences between the two DEA models: Malmquist nonradial and Malmquist radial. Then, one advance model of MPI would be chosen to see these companies' performance in recent years and next few years by using forecasting results of Grey system theory. Totally, the realistic data 14 are considered to be in this evaluation after the strict selection from the whole industry. The results found that all companies have not shown many abrupt changes on their scores, and it is always not consistently good or consistently standing out, which demonstrated the high applicable usability of the integrated methods. This integrated numerical research gives a better “past-present-future” insights into performance evaluation in Indian electricity industry. PMID:25821854

  8. Integrated DEA models and grey system theory to evaluate past-to-future performance: a case of Indian electricity industry.

    Science.gov (United States)

    Wang, Chia-Nan; Nguyen, Nhu-Ty; Tran, Thanh-Tuyen

    2015-01-01

    The growth of economy and population together with the higher demand in energy has created many concerns for the Indian electricity industry whose capacity is at 211 gigawatts mostly in coal-fired plants. Due to insufficient fuel supply, India suffers from a shortage of electricity generation, leading to rolling blackouts; thus, performance evaluation and ranking the industry turn into significant issues. By this study, we expect to evaluate the rankings of these companies under control of the Ministry of Power. Also, this research would like to test if there are any significant differences between the two DEA models: Malmquist nonradial and Malmquist radial. Then, one advance model of MPI would be chosen to see these companies' performance in recent years and next few years by using forecasting results of Grey system theory. Totally, the realistic data 14 are considered to be in this evaluation after the strict selection from the whole industry. The results found that all companies have not shown many abrupt changes on their scores, and it is always not consistently good or consistently standing out, which demonstrated the high applicable usability of the integrated methods. This integrated numerical research gives a better "past-present-future" insights into performance evaluation in Indian electricity industry.

  9. Performance validation of commercially available mobile waste-assay systems: Preliminary report

    International Nuclear Information System (INIS)

    Schanfein, M.; Bonner, C.; Maez, R.

    1997-01-01

    Prior to disposal, nuclear waste must be accurately characterized to identify and quantify the radioactive content to reduce the radioactive hazard to the public. Validation of the waste-assay systems' performance is critical for establishing the credibility of the assay results for storage and disposal purposes. Canberra Nuclear has evaluated regulations worldwide and identified standard, modular, neutron- and gamma-waste-assay systems that can be used to characterize a large portion of existing and newly generated transuranic (TRU) and low-level waste. Before making claims of guaranteeing any system's performance for specific waste types, the standardized systems' performance be evaluated. 7 figs., 11 tabs

  10. Performance scorecard for occupational safety and health management systems

    Directory of Open Access Journals (Sweden)

    Hernâni Veloso Neto

    2012-06-01

    Full Text Available The pro-active and systematic search for best performances should be the two assumptions of any management system, so safety and health management in organizations must also be guided by these same precepts. However, the scientific production evidences that the performance evaluation processes in safety and health continue to be guided, in their essence, by intermittency, reactivity and negativity, which are not consistent with the assumptions referenced above. Therefore, it is essential that health and safety at work management systems (HSW MS are structured from an active and positive viewpoint, focusing on continuous improvement. This implies considering performance evaluation processes that incorporate, on the one hand, monitoring, measuring and verification procedures, and on the other hand, structured matrixes of results that capture the key factors of success, by mobilizing both reactive and proactive indicators. One of the instruments that can fulfill these precepts of health and safety performance evaluation is the SafetyCard, a performance scorecard for HSW MS that we developed and will seek to outline and demonstrate over this paper.

  11. Evaluation and technologic improvement of an enhanced imaging system

    International Nuclear Information System (INIS)

    Henry, D.

    1990-08-01

    Feature-based systems that combine imaging and signal analysis capabilities may be useful for nondestructive evaluation (NDE) of plant components. This report describes the metallurgical evaluation conducted to verify the performance of a feature-based system to discriminate intergranular stress corrosion cracking (IGSCC) from benign geometrical reflectors. The ultrasonic examination results were also evaluated by examination personnel trained in intergranular stress corrosion cracking (IGSCC) detection techniques. The welds were examined prior to their removal from the recirculation and Residual-Heat-Removal (RHR) piping systems of the Peach Bottom Atomic Power Plant, as described in the Phase 2 Interim Report issued in June 1989. In this phase of the program, a metallurgical evaluation was performed on piping system welds that were examined ultrasonically using a feature-based system for analysis. The feature-based system correctly identified crack, but incorrectly identified other features, e.g., root geometry and metallurgical interfaces, as cracks. While the results of the analysis by the feature-based system were not identical to the results of analysis by trained personnel, the overall performance of the feature-based system was comparable to that of the trained personnel. Based on the results of this program, the feature-based system may be useful as a supplementary method of identifying IGSCC indications. When used in conjunction with existing methods and techniques, it could improve the accuracy of IGSCC identification

  12. A Framework for the Relative and Absolute Performance Evaluation of Automated Spectroscopy Systems

    International Nuclear Information System (INIS)

    Portnoy, David; Heimberg, Peter; Heimberg, Jennifer; Feuerbach, Robert; McQuarrie, Allan; Noonan, William; Mattson, John

    2009-01-01

    The development of high-speed, high-performance gamma-ray spectroscopy algorithms is critical to the success of many automated threat detection systems. In response to this need a proliferation of such algorithms has taken place. With this proliferation comes the necessary and non-trivial task of validation. There is (and always will be) insufficient experimental data to determine performance of spectroscopy algorithms over the relevant factor space at any reasonable precision. In the case of gamma-ray spectroscopy, there are hundreds of radioisotopes of interest, which may come in arbitrary admixtures, there are many materials of unknown quantity, which may be found in the intervening space between the source and the detection system, and there are also irregular variations in the detector systems themselves. All of these factors and more should be explored to determine algorithm/system performance. This paper describes a statistical framework for the performance estimation and comparison of gamma-ray spectroscopy algorithms. The framework relies heavily on data of increasing levels of artificiality to sufficiently cover the factor space. At each level rigorous statistical methods are employed to validate performance estimates.

  13. Piloted "Well Clear" Performance Evaluation of Detect-and-Avoid Systems with Suggestive Guidance

    Science.gov (United States)

    Mueller, Eric R.; Santiago, Confesor; Watza, Spencer

    2016-01-01

    This study evaluated the performance of four prototype unmanned aircraft detect-and-avoid (DAA) display configurations, each with different informational elements driven by alerting and guidance algorithms. Sixteen unmanned aircraft pilots flew each combination of the display configurations, with half being given zero DAA surveillance sensor uncertainty and the other half experiencing errors that were comparable, and in some cases slightly better than, errors that were measured in DAA system flight tests. The displays that showed intruder alert information in altitude and heading bands had significantly fewer losses of well clear compared with alternative displays that lacked that information. This difference was significant from a statistical and practical perspective: those losses that did occur lasted for shorter periods and did not penetrate as far into the geometric "separation cylinder" as those in the non-banded displays. A modest level of DAA surveillance sensor uncertainty did not affect the proportion of losses of well clear or their severity. It is recommended that DAA traffic displays implement a band-type display in order to improve the safety of UAS operations in the National Airspace System. Finally, this report provides pilot response time distributions for responding to DAA alerts.

  14. Mobility Models for Systems Evaluation

    Science.gov (United States)

    Musolesi, Mirco; Mascolo, Cecilia

    Mobility models are used to simulate and evaluate the performance of mobile wireless systems and the algorithms and protocols at the basis of them. The definition of realistic mobility models is one of the most critical and, at the same time, difficult aspects of the simulation of applications and systems designed for mobile environments. There are essentially two possible types of mobility patterns that can be used to evaluate mobile network protocols and algorithms by means of simulations: traces and synthetic models [130]. Traces are obtained by means of measurements of deployed systems and usually consist of logs of connectivity or location information, whereas synthetic models are mathematical models, such as sets of equations, which try to capture the movement of the devices.

  15. Performance Evaluation of a Small Scale Modular Solar Trigeneration System

    Directory of Open Access Journals (Sweden)

    Handong Wang

    2014-01-01

    Full Text Available In order to improve the efficiency of solar thermal power (STP system, a novel modular system combining cooling, heating, and power generation (CCHP is proposed and introduced in this work. This modular CCHP system can simultaneously provide 10 kW electricity, −15~5°C coolant, and 60°C hot water to meet the requirements of cooling, heating, and electricity in a general family or other fields. The flow chart and working process of the modular system are introduced, based on which the energy and exergy efficiencies at the CCHP and STP operation modes are primarily evaluated and discussed. The results show that when the output electricity is constant, the overall efficiencies of energy and exergy of the system operating at the CCHP mode are 9.37 times and 2.62 times as big as those of the system operating at the STP mode, respectively. Thus, the modular solar thermal CCHP system can improve the energy and exergy efficiencies. Furthermore, calculation shows that both the overall energy and exergy efficiencies decrease with increase of inlet vapor temperature at given inlet vapor pressure, but both the efficiencies increase with increase of inlet vapor pressure at given inlet temperature.

  16. The Organisational Performance Impact Of ERP Systems On Selected Companies

    Directory of Open Access Journals (Sweden)

    Hart, Colin Anthony

    2014-05-01

    Full Text Available There is a need to determine the performance benefits that firms gain from enterprise resource planning (ERP systems, and the factors that contribute to success. Consequently, the central research problem is: To determine the impact of ERP systems on organisational performance by analysing achieved ERP benefits within the framework of a suitable performance measurement system (PMS, and to investigate the association between critical success factors (CSFs and ERP benefits. A list of expected ERP benefits and CSFs is compiled. Performance measurement models are evaluated, and one model is designed to evaluate ERP impact. ERP experts refine identified ERP benefits and CSFs using structured interviews. These are built into a questionnaire, and used to survey South African (SA companies in manufacturing, mining, and power generation. Results indicate that business benefits are realised by companies that implement ERP systems. By building benefits into the performance measurement model, a positive impact on organisational performance is observed. Although a core list of CSFs is identified, and three associations are found between CSFs and ERP benefits, further research is needed.

  17. A High Performance Pocket-Size System for Evaluations in Acoustic Signal Processing

    Directory of Open Access Journals (Sweden)

    Steeger Gerhard H

    2001-01-01

    Full Text Available Custom-made hardware is attractive for sophisticated signal processing in wearable electroacoustic devices, but has a high initial cost overhead. Thus, signal processing algorithms should be tested thoroughly in real application environments by potential end users prior to the hardware implementation. In addition, the algorithms should be easily alterable during this test phase. A wearable system which meets these requirements has been developed and built. The system is based on the high performance signal processor Motorola DSP56309. This device also includes high quality stereo analog-to-digital-(ADC- and digital-to-analog-(DAC-converters with 20 bit word length each. The available dynamic range exceeds 88 dB. The input and output gains can be adjusted by digitally controlled potentiometers. The housing of the unit is small enough to carry it in a pocket (dimensions 150 × 80 × 25 mm. Software tools have been developed to ease the development of new algorithms. A set of configurable Assembler code modules implements all hardware dependent software routines and gives easy access to the peripherals and interfaces. A comfortable fitting interface allows easy control of the signal processing unit from a PC, even by assistant personnel. The device has proven to be a helpful means for development and field evaluations of advanced new hearing aid algorithms, within interdisciplinary research projects. Now it is offered to the scientific community.

  18. Performance evaluation on vibration control of MR landing gear

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D Y; Nam, Y J; Park, M K [Graduate School, Pusan National University, Busan 609-735 (Korea, Republic of); Yamane, R [Kokushikan University, 4-28-1 Setagaya, Setagaya-ku, Tokyo 154-8515 (Japan)], E-mail: ldy5577@yahoo.co.kr, E-mail: mkpark1@pusan.ac.kr

    2009-02-01

    This paper is concerned with the applicability of the developed MR damper to the landing gear system for the attenuating undesired shock and vibration in the landing and taxing phases. First of all, the experimental model of the MR damper is derived based on the results of performance evaluations. Next, a simplified skyhook controller, which is one of the most straightforward, but effective approaches for improving ride comport in vehicles with active suspensions, is formulated. Then, the vibration control performances of the landing gear system using the MR damper are theoretically evaluated in the landing phase of the aircraft. A series of simulation analyses show that the proposed MR damper with the skyhook controller is effective for suppressing undesired vibration of the aircraft body. Finally, the effectiveness of the simulation results are additionally verified via HILS (Hardware-in-the-loop-simulation) method.

  19. Geotechnical Issues in Total System Performance Assessments of Yucca Mountain

    International Nuclear Information System (INIS)

    HO, CLIFFORD K.; HOUSEWORTH, JIM; WILSON, MICHAEL L.

    1999-01-01

    A Total System Performance Assessment (TSPA) of Yucca Mountain consists of integrated sub-models and analyses of natural and engineered systems. Examples of subsystem models include unsaturated-zone flow and transport, seepage into drifts, coupled thermal hydrologic processes, transport through the engineered barrier system, and saturated-zone flow and transport. The TSPA evaluates the interaction of important processes among these subsystems, and it determines the impact of these processes on the overall performance measures (e.g., dose rate to humans). This paper summarizes the evaluation, abstraction, and combination of these subsystem models in a TSPA calculation, and it provides background on the individual TSPA subsystem components that are most directly impacted by geotechnical issues. The potential impact that geologic features, events, and processes have on the overall performance is presented, and an evaluation of the sensitivity of TSPA calculations to these issues is also provided

  20. Evaluation of components and systems of RSG-GAS and developing of maintenance evaluation software

    International Nuclear Information System (INIS)

    Pane, Jupiter-Sitorus; Kadarusmanto

    2003-01-01

    In order to enhance the evaluation of components and systems, inventarization of failure and repair data has been performed. The evaluation was done by calculating distribution function of failure, failure rate, MTTF, MTTR, and unavailability. The evaluation was comprehend in a code program of SYSCOM-RSG-GAS, that are able to performed statistical analysis, reliability parameters, and Fault Tree Analysis. This paper will describe some results of the program

  1. Geographic information systems - tool for evaluation of the hydro-energy performance of water supply systems

    Directory of Open Access Journals (Sweden)

    Aline Christian Pimentel Almeida Santos

    2017-05-01

    Full Text Available The most relevant challenges in the water supply system (WSS are high water losses and the waste of electric energy. This paper aimed to assess the capacity of the Geographic Information System (GIS in the analysis of the hydro-energy performance of WSSs. The Stage 1 comprises the selection of data and the respective hydro-energy indexes are defined; cartographic data are defined in Stage 2 and a geo-referenced database is constructed in Stage 3. In the stage 4, the data of the Central Water Supply Zone administered by the Water Works Company of the state of Pará in Belém, Brazil were employed to assess its applicability, in which the sectors with the worst hydro-energy performance were identified, such as Sector 9, with the highest water loss rates (59.11% and electric energy consumption per m3 of water produced (1.57 kwh m-³. The results shows that geo-referential assessment of the hydro-energy performance of WSSs provided accurate information for decision-taking related to the rational use of water and electricity in the systems.

  2. Performance assessment of cogeneration and trigeneration systems for small scale applications

    International Nuclear Information System (INIS)

    Angrisani, Giovanni; Akisawa, Atsushi; Marrasso, Elisa; Roselli, Carlo; Sasso, Maurizio

    2016-01-01

    Highlights: • Indices and methods to assess the performance of polygeneration systems. • Index to evaluate the economic feasibility of trigeneration system is introduced. • Thermo-economic analysis is performed considering three commercial cogenerators. • Sensitivity analysis varying reference electric efficiency for European Countries. • Sensitivity analysis varying environmental and economic parameters. - Abstract: Cogeneration and trigeneration systems can contribute to the reduction of primary energy consumption and greenhouse gas emissions in residential and tertiary sectors, by reducing fossil fuels demand and grid losses with respect to conventional systems. To evaluate the performance of these systems, several indices and assessment methodologies can be used, due to the high complexity of such systems, which can consist of several energy conversion devices and can perform bidirectional interactions with external electric and thermal grids. In this paper, a review of the available indices and methodologies to assess the performances of polygeneration systems is provided. An index (TSS_t_r_i) aimed to assess the economic feasibility of a trigeneration system is also introduced and discussed. This activity started in the framework of the International Energy Agency Annex 54 project (“Integration of Micro-Generation and Related Energy Technologies in Buildings”), where research groups shared their expertise about methods applied in each Country to evaluate the performance of polygeneration systems. It was concluded that a thermo-economic analysis comparing the performance of a polygeneration system with those of a reference benchmark scenario, is a very suitable assessment method. Some of the reviewed methodologies are then applied to small scale commercial cogenerators. The sensitivity analysis is performed considering different reference average values of electric efficiency, unitary natural gas and electricity prices, and emission factors for

  3. Performance evaluation of enterprise architecture using fuzzy sequence diagram

    Directory of Open Access Journals (Sweden)

    Mohammad Atasheneh

    2014-01-01

    Full Text Available Developing an Enterprise Architecture is a complex task and to control the complexity of the regulatory framework we need to measure the relative performance of one system against other available systems. On the other hand, enterprise architecture cannot be organized without the use of a logical structure. The framework provides a logical structure for classifying architectural output. Among the common architectural framework, the C4ISR framework and methodology of the product is one of the most popular techniques. In this paper, given the existing uncertainties in system development and information systems, a new version of UML called Fuzzy-UML is proposed for enterprise architecture development based on fuzzy Petri nets. In addition, the performance of the system is also evaluated based on Fuzzy sequence diagram.

  4. Performance characteristics for advanced control systems

    International Nuclear Information System (INIS)

    Kisner, R.A.

    1989-01-01

    A growing collection of control techniques is becoming available to the design engineer. This make selection of the most appropriate technique for a given application a difficult task. A systematic approach to evaluating alternative control schemes is needed. The approach discussed in this paper expands the traditional concepts of quantitative performance analysis to include other relevant factors such as robustness of the technique, resource requirements, and effects on operators and other personnel. This collection of factors, termed measures of utility, may be used as qualitative and quantitative means of evaluating and comparing properties of alternative control system designs. This paper, although not an in-depth study, serves to outline several measures of utility and suggests a general structure for control system development. This method of comparing the usefulness of alternative control system will prove valuable to the ORNL Advanced Controls Program (ACTO) for optimizing compatibility with actual systems and equipment

  5. Are anonymous evaluations a better assessment of faculty teaching performance? A comparative analysis of open and anonymous evaluation processes.

    Science.gov (United States)

    Afonso, Nelia M; Cardozo, Lavoisier J; Mascarenhas, Oswald A J; Aranha, Anil N F; Shah, Chirag

    2005-01-01

    We compared teaching performance of medical school faculty using anonymous evaluations and open evaluations (in which the evaluator was not anonymous) and examined barriers to open evaluation. Residents and medical students evaluated faculty using an open evaluation instrument in which their identity was indicated in the evaluation. Following this, they completed anonymous evaluation on the same faculty members. Aggregate outcomes using the two evaluation systems were compared. Outcomes by group of evaluators (residents and students) were analyzed. Trainees were also asked to rate the barriers to the open evaluation process. A statistically significant difference between the open and anonymous evaluations was noted across all items, with faculty receiving lower scores on the anonymous evaluations. The mean score for all the items on the open evaluations was 4.45 +/- 0.65, compared to mean score of 4.07 +/- 0.80 on the anonymous evaluations. There was also a statistically significant difference between open and anonymous evaluations in five clinical teaching domains that were evaluated individually. Residents perceived that the three most common barriers to optimal evaluation were an apprehension of possible encounters with the same attending physician in the future, destruction of working relationships with the attending, and a feeling of frustration with the evaluation system. The evaluation of faculty teaching performance is complex. Most academic medical centers use the open evaluation format. This study supports the case for the use of the anonymous evaluation method as a more accurate reflection of teaching performance.

  6. Northeast Inspection Services, Inc. boresonic inspection system evaluation

    International Nuclear Information System (INIS)

    Nottingham, L.D.; Sabourin, P.F.; Presson, J.H.

    1993-04-01

    Turbine rotor reliability and remaining life assessment are continuing concerns to electric utilities. Over the years, boresonic inspection and evaluation have served as primary components in rotor remaining life assessment. Beginning with an evaluation of TREES by EPRI in 1982, a series of reports that document the detection and sizing capabilities of several boresonic systems have been made available. These studies should provide utilities with a better understanding of system performance and lead to improved reliability when predicting rotor remaining life. In 1990, the procedures followed for evaluating rotor boresonic performance capabilities were changed to transfer a greater portion of the data analysis function to the participating vendor. This change from previous policy was instituted so that the evaluation results would better reflect the ''final answer'' that a vendor would provide in a real rotor inspection and also to reduce the cost of an evaluation. Among the first vendors to participate in the new performance demonstration was Northeast Inspection Services, Inc. (NISI). The tests reported herein were conducted by NISI personnel under the guidelines of the new plan. Details of the new evaluation plan are also presented. Rotor bore blocks containing surface-connected fatigue cracks, embedded glass beads, and embedded radial-axial oriented disks were used in the evaluation. Data were collected during twenty-five independent passes through the blocks. The evaluation consisted of statistical characterization of the detection capabilities, flaw sizing and location accuracy, and repeatability of the inspection system. The results of the evaluation are included in this report

  7. Defining the Ecological Coefficient of Performance for an Aircraft Propulsion System

    Science.gov (United States)

    Şöhret, Yasin

    2018-05-01

    The aircraft industry, along with other industries, is considered responsible these days regarding environmental issues. Therefore, the performance evaluation of aircraft propulsion systems should be conducted with respect to environmental and ecological considerations. The current paper aims to present the ecological coefficient of performance calculation methodology for aircraft propulsion systems. The ecological coefficient performance is a widely-preferred performance indicator of numerous energy conversion systems. On the basis of thermodynamic laws, the methodology used to determine the ecological coefficient of performance for an aircraft propulsion system is parametrically explained and illustrated in this paper for the first time. For a better understanding, to begin with, the exergy analysis of a turbojet engine is described in detail. Following this, the outputs of the analysis are employed to define the ecological coefficient of performance for a turbojet engine. At the end of the study, the ecological coefficient of performance is evaluated parametrically and discussed depending on selected engine design parameters and performance measures. The author asserts the ecological coefficient of performance to be a beneficial indicator for researchers interested in aircraft propulsion system design and related topics.

  8. Holistic Evaluation of Lightweight Operating Systems using the PERCU Method

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, William T.C.; He, Yun (Helen); Carter, Jonathan; Glenski, Joseph; Rippe, Lynn; Cardo, Nicholas

    2008-05-01

    The scale of Leadership Class Systems presents unique challenges to the features and performance of operating system services. This paper reports results of comprehensive evaluations of two Light Weight Operating Systems (LWOS), Cray's Catamount Virtual Node (CVN) and Linux Environment (CLE) operating systems, on the exact same large-scale hardware. The evaluation was carried out over a 5-month period on NERSC's 19,480 core Cray XT-4, Franklin, using a comprehensive evaluation method that spans Performance, Effectiveness, Reliability, Consistency and Usability criteria for all major subsystems and features. The paper presents the results of the comparison between CVN and CLE, evaluates their relative strengths, and reports observations regarding the world's largest Cray XT-4 as well.

  9. Performance evaluation of an interactive teleradiology system for real-time teleconsultation in different network environments

    International Nuclear Information System (INIS)

    Lian Ping; Gong Jun; Zhuang Jun; Sun Jianyong; Yang Yuanyuan; Zhang Jianguo; Meng Lili

    2004-01-01

    Objective: Measure the performance of self-developed Interoperable teleradiology system at various communication conditions. Methods: Through three different network media ( satellite network, Asymmetrical Digital Subscriber Loop (ADSL), and Shanghai health system's private broadband WAN), Digital images in radiology were transmitted and experiments on teleradiology consultation were applied. Results such as transmission time were recorded, effects of real-time consultation were evaluated subjectively, and experimental data were analyzed. Results: In satellite network, time spent on the transmission of images is long and effects of consultation is normal; in broadband network, time spent is short and no delay is observed in interoperation. Conclusion: teleconsultation can be hold on image sets composed of small matrix size images and compressed large matrix size images in satellite narrowband network, optimum transmission bandwidth is 192 kbps; original large matrix size images such as CR can be transmitted through broadband network and be used in teleconsultation. Real-time interoperation of the system doesn't require very high bandwidth. It can be implemented at various communication conditions

  10. Information system maturity and the hospitality enterprise performance

    Directory of Open Access Journals (Sweden)

    Daniela Garbin Pranicevic

    2015-01-01

    Full Text Available The purpose of this paper is to empirically evaluate the relationship between the maturity of hotels’ information systems and their performance. This study uses customized models of information system (IS maturity and hotel performance measurement. Since we wanted to include the intangible aspects of performance, we opted for an adapted application of the Balanced Scorecard model. In the empirical part of the paper, fundamental constructs of the model are verified, while the individual items are further evaluated by employing discriminant analysis to distinguish hotels with relatively low and high performance levels. The findings demonstrate the existence of a significant and positive relationship between IS maturity and two dimensions of performance in the hospitality industry – process quality and guest relationships. The level of employee development and financial performance do not seem to be related to IS maturity. Although representative, the sample is relatively small, and the primary data were collected in a single country. The paper provides a framework of IS maturity items in the hospitality industry which seem to contribute to hotels’ business performances. As such, it can serve as a practical framework relevant for IT management in tourism and hospitality. The paper addresses a topic already discussed in a range of industries, although it does not seem to have been empirically evaluated by many studies of the tourism and hospitality industry. In addition, a new theoretical model of IT maturity in tourism and hospitality is proposed.

  11. Performance of a daylight-redirecting glass-shading system

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend

    2013-01-01

    to the original system. The visual comfort was evaluated by glare analysis and the redirected daylight did not cause an additional discomfort glare. The higher utilization of daylight can save 20% of the lighting energy. The thermal insulation of the fenestration was maintained, with slightly increased solar......This paper evaluates the daylighting performance of a prototype external dynamic shading and daylight-redirecting system, and the main focus is on the performance simulation. The demonstration project was carried out on a building with an open-plan office. Part of the original façade was replaced...... with the prototype façade. This layout allowed the use of the same orientation and surroundings for both façades. The working plane illuminance was measured over several months and the measurements were accompanied with annual daylight simulations. The prototype system improved the daylighting conditions compared...

  12. Evaluation of the performance of an ultrasonic cross-correlation flowmeter

    International Nuclear Information System (INIS)

    Bazerghi, H.; Serdula, K.J.

    1977-09-01

    An ultrasonic cross-correlation flowmeter, developed to assist in improving performance of heavy water plants, was evaluated. Overall performance of the flowmeter is satisfactory. The flowmeter is ideally suited to industrial applications and has an accuracy and repeatability comparable to many laboratory instruments. An accuracy of 3% is readily obtainable. This new 'clamp-on' portable flowmeter should prove useful in applications which provide flow measurements in systems where pipe penetration is too costly or not practical, verify or replace existing flowmeters, and measure flows in lines not previously instrumented to provide better control or to verify performance of systems

  13. Performance of two different digital evaluation systems used for assessing pre-clinical dental students' prosthodontic technical skills.

    Science.gov (United States)

    Gratton, D G; Kwon, S R; Blanchette, D R; Aquilino, S A

    2017-11-01

    Proper integration of newly emerging digital assessment tools is a central issue in dental education in an effort to provide more accurate and objective feedback to students. The study examined how the outcomes of students' tooth preparation were correlated when evaluated using traditional faculty assessment and two types of digital assessment approaches. Specifically, incorporation of the Romexis Compare 2.0 (Compare) and Sirona prepCheck 1.1 (prepCheck) systems was evaluated. Additionally, satisfaction of students based on the type of software was evaluated through a survey. Students in a second-year pre-clinical prosthodontics course were allocated to either Compare (n = 42) or prepCheck (n = 37) systems. All students received conventional instruction and used their assigned digital system as an additional evaluation tool to aid in assessing their work. Examinations assessed crown preparations of the maxillary right central incisor (#8) and the mandibular left first molar (#19). All submissions were graded by faculty, Compare and prepCheck. Technical scores did not differ between student groups for any of the assessment approaches. Compare and prepCheck had modest, statistically significant correlations with faculty scores with a minimum correlation of 0.3944 (P = 0.0011) and strong, statistically significant correlations with each other with a minimum correlation of 0.8203 (P < 0.0001). A post-course student survey found that 55.26% of the students felt unfavourably about learning the digital evaluation protocols. A total of 62.31% felt favourably about the integration of these digital tools into the curriculum. Comparison of Compare and prepCheck showed no evidence of significant difference in students' prosthodontics technical performance and perception. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Why performance-based contracting failed in Uganda--an "open-box" evaluation of a complex health system intervention.

    Science.gov (United States)

    Ssengooba, Freddie; McPake, Barbara; Palmer, Natasha

    2012-07-01

    Performance-based contracting (PBC) is a tool that links rewards to attainment of measurable performance targets. Significant problems remain in the methods used to evaluate this tool. The primary focus of evaluations on the effects of PBC (black-box) and less attention to how these effects arise (open-box) generates suboptimal policy learning. A black-box impact evaluation of PBC pilot by the Development Research Group of the World Bank (DRG) and the Ministry of Health (MOH) concluded that PBC was ineffective. This paper reports a theory-based case study intended to clarify how and why PBC failed to achieve its objectives. To explain the observed PBC implementation and responses of participants, this case study employed two related theories i.e. complex adaptive system and expectancy theory respectively. A prospective study trailed the implementation of PBC (2003-2006) while collecting experiences of participants at district and hospital levels. Significant problems were encountered in the implementation of PBC that reflected its inadequate design. As problems were encountered, hasty adaptations resulted in a de facto intervention distinct from the one implied at the design stage. For example, inadequate time was allowed for the selection of service targets by the health centres yet they got 'locked-in' to these poor choices. The learning curve and workload among performance auditors weakened the validity of audit results. Above all, financial shortfalls led to delays, short-cuts and uncertainty about the size and payment of bonuses. The lesson for those intending to implement similar interventions is that PBC should not be attempted 'on the cheap'. It requires a plan to boost local institutional and technical capacities of implementers. It also requires careful consideration of the responses of multiple actors - both insiders and outsiders to the intended change process. Given the costs and complexity of PBC implementation, strengthening conventional approaches

  15. Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 2 Heating Season Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Malhotra, Mini [ORNL; Munk, Jeffrey D [ORNL

    2016-08-01

    The performance of two HVAC systems was evaluated using ORNL’s FRP, which is a two-story, 3,200 ft2 (297.3 m2) multi-zone unoccupied building that represents a typical low-rise, small office building common in the US existing building stock. The FRP is equipped with a conventional 12.5 ton (44 kW) RTU-VAV reheat system as the baseline system. For this study, a 12 ton (42 kW) VRF with a dedicated outdoor air system (DOAS) was installed to be compared with the baseline RTU system.

  16. Performance comparison of optical interference cancellation system architectures.

    Science.gov (United States)

    Lu, Maddie; Chang, Matt; Deng, Yanhua; Prucnal, Paul R

    2013-04-10

    The performance of three optics-based interference cancellation systems are compared and contrasted with each other, and with traditional electronic techniques for interference cancellation. The comparison is based on a set of common performance metrics that we have developed for this purpose. It is shown that thorough evaluation of our optical approaches takes into account the traditional notions of depth of cancellation and dynamic range, along with notions of link loss and uniformity of cancellation. Our evaluation shows that our use of optical components affords performance that surpasses traditional electronic approaches, and that the optimal choice for an optical interference canceller requires taking into account the performance metrics discussed in this paper.

  17. Fuzzy inference system for evaluating and improving nuclear power plant operating performance

    International Nuclear Information System (INIS)

    Guimaraes, Antonio Cesar F.; Lapa, Celso Marcelo Franklin

    2003-01-01

    This paper presents a fuzzy inference system (FIS) as an approach to estimate Nuclear Power Plant (NPP) performance indicators. The performance indicators for this study are the energy availability factor (EAF) and the planned (PUF) and unplanned unavailability factor (UUF). These indicators are obtained from a non analytical combination among the same operational parameters. Such parameters are, for example, environment impacts, industrial safety, radiological protection, safety indicators, scram rate, thermal efficiency, and fuel reliability. This approach uses the concept of a pure fuzzy logic system where the fuzzy rule base consists of a collection of fuzzy IF-THEN rules. The fuzzy inference engine uses these fuzzy IF-THEN rules to determine a mapping from fuzzy sets in the input universe of discourse to fuzzy sets in the output universe of discourse based on fuzzy logic principles. The results demonstrated the potential of the fuzzy inference to generate a knowledge basis that correlate operations occurrences and NPP performance. The inference system became possible the development of the sensitivity studies, future operational condition previsions and may support the eventual corrections on operation of the plant

  18. CTBT integrated verification system evaluation model supplement

    International Nuclear Information System (INIS)

    EDENBURN, MICHAEL W.; BUNTING, MARCUS; PAYNE, ARTHUR C. JR.; TROST, LAWRENCE C.

    2000-01-01

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0

  19. Performance evaluation of an IMDD optical OFDM-CDMA system.

    Science.gov (United States)

    Mhatli, Sofien; Mrabet, Hichem; Giacoumidis, Elias; Dayoub, Iyad

    2018-03-01

    In this paper, we propose a modulation technique for passive optical networks that harnesses two-dimensional prime hop system optical code division multiplexing access (OCDMA) and optical orthogonal frequency-division multiplexing (OFDM) for intensity modulation with direct-detection (IMDD) to enhance users' signal capacity in a cost-effective manner. The theoretical analysis is built from an analytical formula that takes into account both multiple-access interference and photodetector noise. Results show that OFDM-OCDMA with multiple users has similar performance to single-user conventional OOFDM for low transmitted powers.

  20. Performance evaluation of a real time OFDM radio over fiber system at 2.5 GHz using software defined radio SDR

    DEFF Research Database (Denmark)

    David Cepeda, Juan; Rodriguez, Santiago Isaac; Rico-Martinez, Monica

    2017-01-01

    This paper presents the implementation of an OFDM radio over fiber (RoF) system at 2.5 GHz using software defined radio (SDR). In this work, first we present an introduction of the main concepts about radio over fiber and an orthogonal frequency-division multiplexing (OFDM) system at 2.5 GHz......, then we present a comparison of an OFDM RoF system in three scenarios, modifying the wireless distances and the optical fiber distance in order to evaluate the performance of the system taking into account the symbol error rate (SER) vs signal to noise ratio (SNR) curves....

  1. Innovative Nuclear Energy Systems: State-of-the Art Survey on Evaluation and Aggregation Judgment Measures Applied to Performance Comparison

    Directory of Open Access Journals (Sweden)

    Vladimir Kuznetsov

    2015-04-01

    Full Text Available This paper summarizes the experience gained in the application of multi-criteria decision making and uncertainty treatment methods to a comparative assessment of nuclear energy systems and related nuclear fuel cycles. These judgment measures provide a means for comprehensive evaluation according to different conflicting criteria, such as costs, benefits and risks, which are inevitably associated with the deployment of advanced technologies. Major findings and recommendations elaborated in international and national projects and studies are reviewed and discussed. A careful analysis is performed for multi-criteria comparative assessment of nuclear energy systems and nuclear fuel cycles on the basis of various evaluation and screening results. The purpose of this paper is to discuss the lessons learned, to share the identified solutions, and indicate promising future directions.

  2. Environmental performance evaluation of Beijing's energy use planning

    International Nuclear Information System (INIS)

    Wang Lei; Xu Linyu; Song Huimin

    2011-01-01

    In line with rapid economic development, urban energy consumption is increasing rapidly, resulting in environmental problems. After considering several methods to evaluate the environmental performance of energy use, including: energy ecological footprint, input-output analysis, emergy-exergy analysis, and multi-criteria decision-making, an environmental performance evaluation model is proposed, which combines the analytical hierarchy process, fuzzy extent analysis, and membership degree analysis. In the model, 18 sub-indicators of environmental performance from energy use planning are classified into four categories: structure of energy use and industry, technology and efficiency of energy use, environmental impacts caused by energy use, and the socio-economic benefits of energy use. Membership degree analysis is applied to each indicator. Three energy use scenarios which are, respectively, environment-friendly, technology-led, and economic policy-led are evaluated. The results show that the technology-led energy use planning is best. The sustainable energy use policies are proposed from three aspects, including optimizing the energy use and industrial structure, encouraging development of energy-saving and air pollution control technologies, and enhancing legislation on energy use management. The policies are helpful to optimize the trade-offs between economic growth and environmental protection in Beijing. - Highlights: → Our paper establishes a system of indicators according to the structure of urban energy use planning. → We have created a comprehensive environmental performance evaluation model in the research. → The model and results can serve as an important basis for decision-making to guide local government.

  3. The Search Performance Evaluation and Prediction in Exploratory Search

    OpenAIRE

    LIU, FEI

    2016-01-01

    The exploratory search for complex search tasks requires an effective search behavior model to evaluate and predict user search performance. Few studies have investigated the relationship between user search behavior and search performance in exploratory search. This research adopts a mixed approach combining search system development, user search experiment, search query log analysis, and multivariate regression analysis to resolve the knowledge gap. Through this study, it is shown that expl...

  4. Performance evaluation software moving object detection and tracking in videos

    CERN Document Server

    Karasulu, Bahadir

    2013-01-01

    Performance Evaluation Software: Moving Object Detection and Tracking in Videos introduces a software approach for the real-time evaluation and performance comparison of the methods specializing in moving object detection and/or tracking (D&T) in video processing. Digital video content analysis is an important item for multimedia content-based indexing (MCBI), content-based video retrieval (CBVR) and visual surveillance systems. There are some frequently-used generic algorithms for video object D&T in the literature, such as Background Subtraction (BS), Continuously Adaptive Mean-shift (CMS),

  5. Design and Performance Evaluation of an Adaptive Resource Management Framework for Distributed Real-Time and Embedded Systems

    Directory of Open Access Journals (Sweden)

    Chen Yingming

    2008-01-01

    Full Text Available Abstract Achieving end-to-end quality of service (QoS in distributed real-time embedded (DRE systems require QoS support and enforcement from their underlying operating platforms that integrates many real-time capabilities, such as QoS-enabled network protocols, real-time operating system scheduling mechanisms and policies, and real-time middleware services. As standards-based quality of service (QoS enabled component middleware automates integration and configuration activities, it is increasingly being used as a platform for developing open DRE systems that execute in environments where operational conditions, input workload, and resource availability cannot be characterized accurately a priori. Although QoS-enabled component middleware offers many desirable features, however, it historically lacked the ability to allocate resources efficiently and enable the system to adapt to fluctuations in input workload, resource availability, and operating conditions. This paper presents three contributions to research on adaptive resource management for component-based open DRE systems. First, we describe the structure and functionality of the resource allocation and control engine (RACE, which is an open-source adaptive resource management framework built atop standards-based QoS-enabled component middleware. Second, we demonstrate and evaluate the effectiveness of RACE in the context of a representative open DRE system: NASA's magnetospheric multiscale mission system. Third, we present an empirical evaluation of RACE's scalability as the number of nodes and applications in a DRE system grows. Our results show that RACE is a scalable adaptive resource management framework and yields a predictable and high-performance system, even in the face of changing operational conditions and input workload.

  6. Design and Performance Evaluation of an Adaptive Resource Management Framework for Distributed Real-Time and Embedded Systems

    Directory of Open Access Journals (Sweden)

    Chenyang Lu

    2008-04-01

    Full Text Available Achieving end-to-end quality of service (QoS in distributed real-time embedded (DRE systems require QoS support and enforcement from their underlying operating platforms that integrates many real-time capabilities, such as QoS-enabled network protocols, real-time operating system scheduling mechanisms and policies, and real-time middleware services. As standards-based quality of service (QoS enabled component middleware automates integration and configuration activities, it is increasingly being used as a platform for developing open DRE systems that execute in environments where operational conditions, input workload, and resource availability cannot be characterized accurately a priori. Although QoS-enabled component middleware offers many desirable features, however, it historically lacked the ability to allocate resources efficiently and enable the system to adapt to fluctuations in input workload, resource availability, and operating conditions. This paper presents three contributions to research on adaptive resource management for component-based open DRE systems. First, we describe the structure and functionality of the resource allocation and control engine (RACE, which is an open-source adaptive resource management framework built atop standards-based QoS-enabled component middleware. Second, we demonstrate and evaluate the effectiveness of RACE in the context of a representative open DRE system: NASA's magnetospheric multiscale mission system. Third, we present an empirical evaluation of RACE's scalability as the number of nodes and applications in a DRE system grows. Our results show that RACE is a scalable adaptive resource management framework and yields a predictable and high-performance system, even in the face of changing operational conditions and input workload.

  7. Human-system interface evaluation system for advanced control room based on SQL database

    International Nuclear Information System (INIS)

    Zhang Yan; Zhou Zhiwei; Bian Zhiqiang; Xu Li

    2005-01-01

    User Interface (UI) plays an important role in the advanced control room (ACR) of a nuclear power plant (NPP). In this paper, we present a rule-based ACR Human-system Interface Evaluation System (AHSIES) using expert system technology, which can evaluate UI design shortcomings, propose modification suggestions, and help designer improve the ACR interface design. AHSIES consists of four programs: the UI Editor, the Operation Procedure Manager, the Operation Simulator and the UI Design Evaluator. These four parts respectively function for: editing a set of UI icons employed as the operation screens of an advanced control room; for editing operation procedures aiming at any specified operation with simple language; for simulate the operation sequences dynamically and recording the relevant information for design performance of the UIs; and for evaluating both static and dynamic performance of the ACR UI design according to well established design guidelines and criteria with the information gained from the first three programs. Microsoft SQL Server 2000 DBMS is adopted to manage the voluminous data and its complex relationships. The preliminary test application of AHSIES for a simplified ACR UI design of a PWR NPP has shown that the expert evaluation system is capable of achieving satisfactory evaluation results. (authors)

  8. Frequency domain performance analysis of marginally stable LTI systems with saturation

    NARCIS (Netherlands)

    Berg, van den R.A.; Pogromski, A.Y.; Rooda, J.E.; Leonov, G.; Nijmeijer, H.; Pogromsky, A.; Fradkov, A.

    2009-01-01

    In this paper we discuss the frequency domain performance analysis of a marginally stable linear time-invariant (LTI) system with saturation in the feedback loop. We present two methods, both based on the notion of convergent systems, that allow to evaluate the performance of this type of systems in

  9. Environmental performance evaluation of hot water supplying systems for domestic use

    OpenAIRE

    Luiz Alexandre Kulay; Rafael Selvaggio Viñas; Ivanildo Hespanhol

    2015-01-01

    The consumption profile of Brazilian citizens is changing as alternatives are sought to reduce costs. A major focus of this change of attitude involves expenditures for electricity, particularly in relation to water heating systems. The manufacturers of these devices add value to their products beyond price. A usual strategy is the enhancement of the environmental performance of the product. This study compared four water heating systems: electric, gas, solar and hybrid, using an environmenta...

  10. UN Women’s experience with strengthening evaluation systems in Africa: Enhancing quantity, quality and use of evaluations

    Directory of Open Access Journals (Sweden)

    Caspar Merkle

    2016-12-01

    Full Text Available Background: Following the adoption of the Women Evaluation Policy in 2012, a series of systems and mechanisms were introduced in the organisation to strengthen the evaluation function at both central and decentralised levels. They were based on a systemic approach and a Theory of Change for building an enabling environment for evaluation in UN Women. Objectives: The purpose of this article was to analyse progress made and challenges with respect to establishing evaluation systems and institutionalising an evaluation culture in the UN Women Africa region. Method: The article draws on UN Women evaluation performance data collected over the past five years, discussions and practical experience by the author of working on evaluation with UN Women since 2009. It also analyses UN Women documents and the broader literature on the topic. Results: The findings illustrate that the different mechanisms to strengthen the evaluation function in UN Women show progress in the Africa region on four out of the five selected evaluation performance indicators. The Theory of Change to strengthen the UN Women evaluation function is largely validated by the wider literature on evaluation use. External assessments confirm that the UN Women evaluation function is sound overall. Conclusion: The article concludes that evaluation performance indicators only provide a partial snapshot of the many different factors that help or undermine evaluative thinking and a learning culture within an organisation. Institutional systems and mechanisms are necessary but not sufficient for nurturing an evaluation culture and ensuring utilisation of evaluation for better development effectiveness.

  11. Research on Appraisal System of Procurator Performance by Using High-Order CFA Model

    Directory of Open Access Journals (Sweden)

    Yong-mao Huang

    2014-01-01

    Full Text Available The prosecutor is the main body of procuratorial organs. The performance appraisal system plays an important role in promoting the work efficiency of procurator. In this paper, we establish the performance appraisal system of procurators by high-order confirmatory factor analysis method and evaluate procurators’ performance by fuzzy comprehensive evaluation method based on the 360 degrees. The results have some help to performance management of procuratorial organs.

  12. The Evaluation of Higher Education Expenditure Performance and Investment Mechanism Reform

    Science.gov (United States)

    Wang, De; Fu, Meiying

    2009-01-01

    Along with the reform of Chinese Government public finance, higher education belongs to the public product, gradually changes from "fund investment management" to the "expenditure performance management". The evaluation of expenditure performance system becomes the key point of higher education investment mechanism reform. This…

  13. Dual throat NaK pump performance evaluation (conceptual design of prototype)

    International Nuclear Information System (INIS)

    Johnson, J.L.

    1972-01-01

    An evaluation of the performance of the dual throat NaK pump for the 5 Kwe Reactor TE System is discussed. Performance at nominal operating conditions and at startup conditions is predicted. The basis for selection of this pump design is presented. (U.S.)

  14. Evaluation of heat exchange performance for primary pressurized water cooler in HTTR

    International Nuclear Information System (INIS)

    Tochio, Daisuke; Nakagawa, Shigeaki

    2006-01-01

    In High Temperature Engineering Test Reactor (HTTR), the rated thermal power of 30 MW, the generated heat at reactor core is finally dissipated at the air-cooler by way of the heat exchangers of the primary cooling system, such as the primary pressurized water cooler (PPWC) and the intermediate heat exchanger (IHX). The heat exchangers in the primary cooling system are required the heat exchange performance to remove reactor generated heat 30 MW under the condition of reactor coolant outlet temperature 850degC/950degC. Therefore, the heat exchanges are required to satisfy the design criteria of heat exchange performance. In this report, heat exchange performance data of the rise-to-power-up test and the in-service operation for the PPWC in the main cooling system was evaluated. Moreover, the evaluated values were compared with the design values, and it is confirmed that PPWC has the required heat exchange performance in the design. (author)

  15. Evaluation of heat exchange performance for secondary pressurized water cooler in HTTR

    International Nuclear Information System (INIS)

    Tochio, Daisuke; Watanabe, Syuji; Saikusa, Akio; Oyama, Sunao; Nemoto, Takahiro; Hamamoto, Shinpei; Shinohara, Masanori; Isozaki, Minoru; Nakagawa, Shigeaki

    2006-02-01

    In High Temperature Engineering Test Reactor (HTTR), the rated thermal power of 30MW, the generated heat at reactor core is finally dissipated at the air-cooler by way of the heat exchangers of the primary cooling system, such as the intermediate heat exchanger (IHX) and the secondary pressurized water cooler (SPWC). The heat exchangers in the main cooling system are required the heat exchange performance to remove the reactor-generated-heat of 30MW under the condition of reactor coolant outlet temperature of 850degC/950degC. Therefore, the heat exchanges are required to satisfy the design criteria of heat exchange performance. In this report, heat exchange performance of the SPWC in the main cooling system was evaluated with the rise-to-power-up test and the in-service operation data. Moreover, evaluated value is compared with designed one, it is confirmed that the SPWC has required heat exchange performance. (author)

  16. [Performance evaluation of Rapid™ Yeast Plus (Remel) system from two different culture media].

    Science.gov (United States)

    Romeo, Ana M; Snitman, Gabriela V; Marucco, Andrea P; Ponce, Graciela Del V; Cataldi, Silvana P; Guelfand, Liliana I; Arechavala, Alicia

    Within the genus Candida, Candida albicans is the most commonly isolated species from clinical samples. Due to the emergence of other species which can show a higher index of antifungal resistance, a fast identification of these species is necessary. The aim of this work was to evaluate the performance of the RapID Yeast Plus system from two different subculture media formulations: Sabouraud dextrose agar adjusted by Emmons (the medium is indicated in the equipment insert) and Sabouraud glucose agar, which is the most frequently used in Buenos Aires City laboratories. One hundred and sixty-six clinical sample strains coming from different hospitals belonging to the Mycology Network of Buenos Aires City were studied. From the obtained results, we conclude that the conditions and culture medium indicated by the manufacturer should be followed. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  18. Solar power plant performance evaluation: simulation and experimental validation

    Science.gov (United States)

    Natsheh, E. M.; Albarbar, A.

    2012-05-01

    In this work the performance of solar power plant is evaluated based on a developed model comprise photovoltaic array, battery storage, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P&O) algorithm is used for maximizing the generated power based on maximum power point tracker (MPPT) implementation. The outcome of the developed model are validated and supported by a case study carried out using operational 28.8kW grid-connected solar power plant located in central Manchester. Measurements were taken over 21 month's period; using hourly average irradiance and cell temperature. It was found that system degradation could be clearly monitored by determining the residual (the difference) between the output power predicted by the model and the actual measured power parameters. It was found that the residual exceeded the healthy threshold, 1.7kW, due to heavy snow in Manchester last winter. More important, the developed performance evaluation technique could be adopted to detect any other reasons that may degrade the performance of the P V panels such as shading and dirt. Repeatability and reliability of the developed system performance were validated during this period. Good agreement was achieved between the theoretical simulation and the real time measurement taken the online grid connected solar power plant.

  19. Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications

    DEFF Research Database (Denmark)

    Hiller, Jochen; Maisl, Michael; Reindl, Leonard M

    2012-01-01

    This paper presents physical and metrological characterization measurements conducted for an industrial x-ray micro-computed tomography (CT) system. As is well known in CT metrology, many factors, e.g., in the scanning and reconstruction process, the image processing, and the 3D data evaluation...... components of a CT scanner, i.e. the x-ray tube and the flat-panel detector, are characterized. The contrast and noise transfer property of the scanner is obtained using image-processing methods based on linear systems theory. A long-term temperature measurement in the scanner cabinet has been carried out....... The dimensional measurement property has been quantified by using a calibrated ball-bar and uncertainty budgeting. Information about the performance of a CT scanner system in terms of contrast and noise transmission and sources of geometrical errors will help plan CT scans more efficiently. In particular...

  20. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    International Nuclear Information System (INIS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-01-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance

  1. Evaluation of pipeline leak detection systems

    International Nuclear Information System (INIS)

    Glauz, W.D.; Flora, J.D.; Hennon, G.J.

    1993-01-01

    Leaking underground storage tank system presents an environmental concern and a potential health hazard. It is well known that leaks in the piping associated with these systems account for a sizeable fraction of the leaks. EPA has established performance standards for pipeline leak detection systems, and published a document presenting test protocols for evaluating these systems against the standards. This paper discusses a number of facets and important features of evaluating such systems, and presents results from tests of several systems. The importance of temperature differences between the ground and the product in the line is shown both in theory and with test data. The impact of the amount of soil moisture present is addressed, along with the effect of frozen soil. These features are addressed both for line tightness test systems, which must detect leaks of 0.10 gal/h (0.38 L/h) at 150% of normal line pressure, or 0.20 gal/h (0.76 L/h) at normal line pressure, and for automatic line leak detectors that must detect leaks of 3 gal/h (11 L/h) at 10 psi (69 kPa) within an hour of the occurrence of the leak. This paper also addresses some statistical aspects of the evaluation of these systems. Reasons for keeping the evaluation process ''blind'' to the evaluated company are given, along with methods for assuring that the tests are blind. Most importantly, a test procedure is presented for evaluating systems that report a flow rate (not just a pass/fail decision) that is much more efficient than the procedure presented in the EPA protocol, and is just as stringent

  2. Corrosion evaluation of service water system materials

    International Nuclear Information System (INIS)

    Stein, A.A.; Felder, C.M.; Martin, R.L.

    1994-01-01

    The availability and reliability of the service water system is critical for safe operation of a nuclear power plant. Degradation of the system piping and components has forced utilities to re-evaluate the corrosion behavior of current and alternative system materials, to support assessments of the remaining service life of the service water system, selection of replacement materials, implementation of corrosion protection methods and corrosion monitoring programs, and identification of maintenance and operational constraints consistent with the materials used. TU Electric and Stone and Webster developed a service water materials evaluation program for the Comanche Peak Steam Electric Station. Because of the length of exposure and the generic interest in this program by the nuclear power industry, EPRI joined TU to co-sponsor the test program. The program was designed to evaluate the corrosion behavior of current system materials and candidate replacement materials and to determine the operational and design changes which could improve the corrosion performance of the system. Although the test program was designed to be representative of service water system materials and environments targeted to conditions at Comanche Peak, these conditions are typical of and relevant to other fresh water cooled nuclear service water systems. Testing was performed in raw water and water treated with biocide under typical service water operating conditions including continuous flow, intermittent flow, and stagnant conditions. The test program evaluated the 300 Series and 6% molybdenum stainless steels, copper-nickel, titanium, carbon steel, and a formed-in-place nonmetallic pipe lining to determine susceptibility to general, crevice, and microbiologically influenced corrosion and pitting attack. This report presents the results of the test program after 4 years of exposure

  3. Performance of a thermal neutron radiographic system using imaging plates

    International Nuclear Information System (INIS)

    Silvani, Maria Ines; Almeida, Gevaldo L. de; Furieri, Rosanne; Lopes, Ricardo T.

    2009-01-01

    A performance evaluation of a neutron radiographic system equipped with a thermal neutron sensitive imaging plate has been undertaken. It includes the assessment of spatial resolution, linearity, dynamic range and the response to exposure time, as well as a comparison of these parameters with the equivalent ones for neutron radiography employing conventional films and a gadolinium foil as converter. The evaluation and comparison between the radiographic systems have been performed at the Instituto de Engenharia Nuclear - CNEN, using the Argonauta Reactor as source of thermal neutrons and a commercially available imaging plate reader. (author)

  4. Research on the Environmental Performance Evaluation of Electronic Waste Reverse Logistics Enterprise

    Science.gov (United States)

    Yang, Yu-Xiang; Chen, Fei-Yang; Tong, Tong

    According to the characteristic of e-waste reverse logistics, environmental performance evaluation system of electronic waste reverse logistics enterprise is proposed. We use fuzzy analytic hierarchy process method to evaluate the system. In addition, this paper analyzes the enterprise X, as an example, to discuss the evaluation method. It's important to point out attributes and indexes which should be strengthen during the process of ewaste reverse logistics and provide guidance suggestions to domestic e-waste reverse logistics enterprises.

  5. System performance optimization

    International Nuclear Information System (INIS)

    Bednarz, R.J.

    1978-01-01

    The System Performance Optimization has become an important and difficult field for large scientific computer centres. Important because the centres must satisfy increasing user demands at the lowest possible cost. Difficult because the System Performance Optimization requires a deep understanding of hardware, software and workload. The optimization is a dynamic process depending on the changes in hardware configuration, current level of the operating system and user generated workload. With the increasing complication of the computer system and software, the field for the optimization manoeuvres broadens. The hardware of two manufacturers IBM and CDC is discussed. Four IBM and two CDC operating systems are described. The description concentrates on the organization of the operating systems, the job scheduling and I/O handling. The performance definitions, workload specification and tools for the system stimulation are given. The measurement tools for the System Performance Optimization are described. The results of the measurement and various methods used for the operating system tuning are discussed. (Auth.)

  6. Oil Bypass Filter Technology Performance Evaluation - First Quarterly Report

    Energy Technology Data Exchange (ETDEWEB)

    Zirker, L.R.; Francfort, J.E.

    2003-01-31

    This report details the initial activities to evaluate the performance of the oil bypass filter technology being tested by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy's FreedomCAR & Vehicle Technologies Program. Eight full-size, four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass systems from the puraDYN Corporation. Each bus averages about 60,000 miles a year. The evaluation includes an oil analysis regime to monitor the presence of necessary additives in the oil and to detect undesirable contaminants. Very preliminary economic analysis suggests that the oil bypass system can reduce life-cycle costs. As the evaluation continues and oil avoidance costs are quantified, it is estimated that the bypass system economics may prove increasingly favorable, given the anticipated savings in operational costs and in reduced use of oil and waste oil avoidance.

  7. Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93

    International Nuclear Information System (INIS)

    Muhogora, Wilbroad; Padovani, Renato; Bonutti, Faustino; Msaki, Peter; Kazema, R.

    2011-01-01

    The performances of three clinical computed radiography (CR) systems (Agfa CR 75 (with CRMD 4. 0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers' characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly. (author)

  8. Performance evaluation of three computed radiography systems using methods recommended in American Association of Physicists in Medicine Report 93

    Directory of Open Access Journals (Sweden)

    Wilbroad Muhogora

    2011-01-01

    Full Text Available The performances of three clinical computed radiography (CR systems, (Agfa CR 75 (with CRMD 4.0 image plates, Kodak CR 850 (with Kodak GP plates and Kodak CR 850A (with Kodak GP plates were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers′ characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009 and for Kodak CR systems (P=0.006 probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284 suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly.

  9. Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013.

    Science.gov (United States)

    Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Jendrike, Nina; Haug, Cornelia; Freckmann, Guido

    2016-05-01

    Objective For patients with diabetes, regular self-monitoring of blood glucose (SMBG) is essential to ensure adequate glycemic control. Therefore, accurate and reliable blood glucose measurements with SMBG systems are necessary. The international standard ISO 15197 describes requirements for SMBG systems, such as limits within which 95% of glucose results have to fall to reach acceptable system accuracy. The 2013 version of this standard sets higher demands, especially regarding system accuracy, than the currently still valid edition. ISO 15197 can be applied by manufacturers to receive a CE mark for their system. Research design and methods This study was an accuracy evaluation following ISO 15197:2013 section 6.3 of two recently updated SMBG systems (Contour * and Contour TS; Bayer Consumer Care AG, Basel, Switzerland) with an improved algorithm to investigate whether the systems fulfill the requirements of the new standard. For this purpose, capillary blood samples of approximately 100 participants were measured with three test strip lots of both systems and deviations from glucose values obtained with a hexokinase-based comparison method (Cobas Integra † 400 plus; Roche Instrument Center, Rotkreuz, Switzerland) were determined. Percentages of values within the acceptance criteria of ISO 15197:2013 were calculated. This study was registered at clinicaltrials.gov (NCT02358408). Main outcome Both updated systems fulfilled the system accuracy requirements of ISO 15197:2013 as 98.5% to 100% of the results were within the stipulated limits. Furthermore, all results were within the clinically non-critical zones A and B of the consensus error grid for type 1 diabetes. Conclusions The technical improvement of the systems ensured compliance with ISO 15197 in the hands of healthcare professionals even in its more stringent 2013 version. Alternative presentation of system accuracy results in radar plots provides additional information with certain advantages. In addition

  10. System evaluation of logistics performance: Proposal for a supply network in a Public Higher Education Institution

    Directory of Open Access Journals (Sweden)

    Alberto de Oliveira Cardoso Neto

    2017-06-01

    Full Text Available The recent quest for efficiency in public companies in Brazil was one of the motives to elaborate this paper, which had a public Institution of Higher Education (IHE as its subject of study. The IHE profiled possesses a multi-campus structure and the distribution of its consumer items is performed by the institution’s own warehouse. Through field research, it became apparent that the supply of these items had some problems, such as items out of stock, orders with delayed delivery, items past their shelf life etc. Therefore, this paper article aimed to propose an evaluation system of the logistical services at the IHE studied, based on performance indicators developed from mangers’ perceptions about the problems occurring in the distribution of consumer items. In addition, an index, calculated from diverse indicators, was proposed which would be able to express the performance of the logistics service of the IHE studied, and reflect the perceptions of the main users of this service. It is understood that the solution proposed here can be applied to any two-echelon supply network.

  11. An Examination of Organizatinal Performance Measurement System Utilization

    OpenAIRE

    DeBusk, Gerald Kenneth

    2003-01-01

    This dissertation provides results of three studies, which examine the utilization of organizational performance measurement systems. Evidence gathered in the first study provides insight into the number of perspectives or components found in the evaluation of an organization's performance and the relative weight placed on those components. The evidence suggests that the number of performance measurement components and their relative composition is situational. Components depend heavily on th...

  12. Performance metrics for the evaluation of hyperspectral chemical identification systems

    Science.gov (United States)

    Truslow, Eric; Golowich, Steven; Manolakis, Dimitris; Ingle, Vinay

    2016-02-01

    Remote sensing of chemical vapor plumes is a difficult but important task for many military and civilian applications. Hyperspectral sensors operating in the long-wave infrared regime have well-demonstrated detection capabilities. However, the identification of a plume's chemical constituents, based on a chemical library, is a multiple hypothesis testing problem which standard detection metrics do not fully describe. We propose using an additional performance metric for identification based on the so-called Dice index. Our approach partitions and weights a confusion matrix to develop both the standard detection metrics and identification metric. Using the proposed metrics, we demonstrate that the intuitive system design of a detector bank followed by an identifier is indeed justified when incorporating performance information beyond the standard detection metrics.

  13. Manipulator system man-machine interface evaluation program. [technology assessment

    Science.gov (United States)

    Malone, T. B.; Kirkpatrick, M.; Shields, N. L.

    1974-01-01

    Application and requirements for remote manipulator systems for future space missions were investigated. A manipulator evaluation program was established to study the effects of various systems parameters on operator performance of tasks necessary for remotely manned missions. The program and laboratory facilities are described. Evaluation criteria and philosophy are discussed.

  14. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-01-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  15. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-05-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  16. Performance Evaluation of Hadoop-based Large-scale Network Traffic Analysis Cluster

    Directory of Open Access Journals (Sweden)

    Tao Ran

    2016-01-01

    Full Text Available As Hadoop has gained popularity in big data era, it is widely used in various fields. The self-design and self-developed large-scale network traffic analysis cluster works well based on Hadoop, with off-line applications running on it to analyze the massive network traffic data. On purpose of scientifically and reasonably evaluating the performance of analysis cluster, we propose a performance evaluation system. Firstly, we set the execution times of three benchmark applications as the benchmark of the performance, and pick 40 metrics of customized statistical resource data. Then we identify the relationship between the resource data and the execution times by a statistic modeling analysis approach, which is composed of principal component analysis and multiple linear regression. After training models by historical data, we can predict the execution times by current resource data. Finally, we evaluate the performance of analysis cluster by the validated predicting of execution times. Experimental results show that the predicted execution times by trained models are within acceptable error range, and the evaluation results of performance are accurate and reliable.

  17. Hanford high-level waste melter system evaluation data packages

    International Nuclear Information System (INIS)

    Elliott, M.L.; Shafer, P.J.; Lamar, D.A.; Merrill, R.A.; Grunewald, W.; Roth, G.; Tobie, W.

    1996-03-01

    The Tank Waste Remediation System is selecting a reference melter system for the Hanford High-Level Waste vitrification plant. A melter evaluation was conducted in FY 1994 to narrow down the long list of potential melter technologies to a few for testing. A formal evaluation was performed by a Melter Selection Working Group (MSWG), which met in June and August 1994. At the June meeting, MSWG evaluated 15 technologies and selected six for more thorough evaluation at the Aug. meeting. All 6 were variations of joule-heated or induction-heated melters. Between the June and August meetings, Hanford site staff and consultants compiled data packages for each of the six melter technologies as well as variants of the baseline technologies. Information was solicited from melter candidate vendors to supplement existing information. This document contains the data packages compiled to provide background information to MSWG in support of the evaluation of the six technologies. (A separate evaluation was performed by Fluor Daniel, Inc. to identify balance of plant impacts if a given melter system was selected.)

  18. Performance modelling for product development of advanced window systems

    DEFF Research Database (Denmark)

    Appelfeld, David

    properties (chapter 5) of CFSs. The last chapter concludes the thesis and the individual investigations. It is complicated to holistically evaluate the performance of a prototyped system, since simulation programs evaluate standardised products such as aluminium venetian blinds. State-of-the-art tools......The research presented in this doctoral thesis shows how the product development (PD) of Complex Fenestration Systems (CFSs) can be facilitated by computer-based analysis to improve the energy efficiency of fenestration systems as well as to improve the indoor environment. The first chapter defines...... the hypothesis and objectives of the thesis, which is followed by an extended introduction and background. The third chapter briefly suggests the PD framework which is suitable for CFSs. The fourth and fifth chapter refer to the detailed performance modelling of thermal properties (chapter 4) and optical...

  19. Design and Performance Evaluation on Ultra-Wideband Time-Of-Arrival 3D Tracking System

    Science.gov (United States)

    Ni, Jianjun; Arndt, Dickey; Ngo, Phong; Dusl, John

    2012-01-01

    A three-dimensional (3D) Ultra-Wideband (UWB) Time--of-Arrival (TOA) tracking system has been studied at NASA Johnson Space Center (JSC) to provide the tracking capability inside the International Space Station (ISS) modules for various applications. One of applications is to locate and report the location where crew experienced possible high level of carbon-dioxide and felt upset. In order to accurately locate those places in a multipath intensive environment like ISS modules, it requires a robust real-time location system (RTLS) which can provide the required accuracy and update rate. A 3D UWB TOA tracking system with two-way ranging has been proposed and studied. The designed system will be tested in the Wireless Habitat Testbed which simulates the ISS module environment. In this presentation, we discuss the 3D TOA tracking algorithm and the performance evaluation based on different tracking baseline configurations. The simulation results show that two configurations of the tracking baseline are feasible. With 100 picoseconds standard deviation (STD) of TOA estimates, the average tracking error 0.2392 feet (about 7 centimeters) can be achieved for configuration Twisted Rectangle while the average tracking error 0.9183 feet (about 28 centimeters) can be achieved for configuration Slightly-Twisted Top Rectangle . The tracking accuracy can be further improved with the improvement of the STD of TOA estimates. With 10 picoseconds STD of TOA estimates, the average tracking error 0.0239 feet (less than 1 centimeter) can be achieved for configuration "Twisted Rectangle".

  20. CTBT integrated verification system evaluation model supplement

    Energy Technology Data Exchange (ETDEWEB)

    EDENBURN,MICHAEL W.; BUNTING,MARCUS; PAYNE JR.,ARTHUR C.; TROST,LAWRENCE C.

    2000-03-02

    Sandia National Laboratories has developed a computer based model called IVSEM (Integrated Verification System Evaluation Model) to estimate the performance of a nuclear detonation monitoring system. The IVSEM project was initiated in June 1994, by Sandia's Monitoring Systems and Technology Center and has been funded by the U.S. Department of Energy's Office of Nonproliferation and National Security (DOE/NN). IVSEM is a simple, ''top-level,'' modeling tool which estimates the performance of a Comprehensive Nuclear Test Ban Treaty (CTBT) monitoring system and can help explore the impact of various sensor system concepts and technology advancements on CTBT monitoring. One of IVSEM's unique features is that it integrates results from the various CTBT sensor technologies (seismic, in sound, radionuclide, and hydroacoustic) and allows the user to investigate synergy among the technologies. Specifically, IVSEM estimates the detection effectiveness (probability of detection), location accuracy, and identification capability of the integrated system and of each technology subsystem individually. The model attempts to accurately estimate the monitoring system's performance at medium interfaces (air-land, air-water) and for some evasive testing methods such as seismic decoupling. The original IVSEM report, CTBT Integrated Verification System Evaluation Model, SAND97-25 18, described version 1.2 of IVSEM. This report describes the changes made to IVSEM version 1.2 and the addition of identification capability estimates that have been incorporated into IVSEM version 2.0.