WorldWideScience

Sample records for system ii resonance

  1. Identification of problems when using long high voltage AC cable in transmission system II: Resonance & Harmonic resonance

    DEFF Research Database (Denmark)

    Rahimi, Saeed; Wiechowski, W.; Randrup, M.

    2008-01-01

    cable in transmission system. The objective of this paper and the companion paper is to address the most important problems expected in transmission system with relatively larger share of long HV underground cables. The end goal will be a guideline to special solutions and precautions to avoid dangerous...

  2. Determination of metallothioneins by fluorescence and resonance light scattering strategies based on ciprofloxacin–Cu(II) system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Lu [College of Public Health, University of South China, Hengyang 421001 (China); Wang, Yong-Sheng, E-mail: yongsheng.w@tom.com [College of Public Health, University of South China, Hengyang 421001 (China); Xue, Jin-Hua; Yang, Hui-Xian; Li, Qiu; Zhou, Bin; Wang, Jia-Cheng; Yin, Ji-Cheng; Wang, Yong-Song [College of Public Health, University of South China, Hengyang 421001 (China); Xiao, Xi-Lin [College of Chemistry and Chemical Engineering, University of South China, Hengyang 421001 (China)

    2013-06-15

    Based on ciprofloxacin (CIP)–Cu(II) system, the novel methods for the detection of metallothioneins (MTs) have been developed by fluorescence (FL) and resonance light scattering (RLS) strategies. The FL strategy avoids the label and derivatization steps in common methods, while the RLS strategy can be applied for determining bio-macromolecules and small molecules without native fluorescence. The response signals linearly correlated with the concentration of MTs over the ranges of 1.03×10{sup −8}–1.23×10{sup −6} mol L{sup −1} for FL, and of 2.56×10{sup −7}–1.54×10{sup −6} mol L{sup −1} for RLS. The limits of detection (LOD) are 3.1×10{sup −9} mol L{sup −1} for FL and 7.68×10{sup −8} mol L{sup −1} for RLS. This study represents the comparison of these two methods using the same CIP–Cu{sup 2+}–MTs system. They not only allow practical application for MTs detection but also serve as a potential choice for the operators according to their concrete needs. In addition, the mechanisms for FL and RLS enhancement of the system were also discussed. -- Highlights: ► Determination of MTs was developed based on CIP–Cu(II) system by FL and RLS strategies. ► FL strategy provides lower limit of detection and wider linear range, and avoids the label and derivatization steps. ► RLS strategy can be applied for determining bio-macromolecules and small molecules. ► The mechanism of interaction of MTs with CIP–Cu(II) chelate was discussed.

  3. High Efficiency Three Phase Resonant Conversion for Standardized Architecture Power System Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A low-cost, standardized-architecture power system is proposed for NASA electric propulsion (EP) applications. Three approaches are combined to develop a system that...

  4. Ovenized microelectromechanical system (MEMS) resonator

    Science.gov (United States)

    Olsson, Roy H; Wojciechowski, Kenneth; Kim, Bongsang

    2014-03-11

    An ovenized micro-electro-mechanical system (MEMS) resonator including: a substantially thermally isolated mechanical resonator cavity; a mechanical oscillator coupled to the mechanical resonator cavity; and a heating element formed on the mechanical resonator cavity.

  5. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  6. Quartz resonator processing system

    Science.gov (United States)

    Peters, Roswell D. M.

    1983-01-01

    Disclosed is a single chamber ultra-high vacuum processing system for the oduction of hermetically sealed quartz resonators wherein electrode metallization and sealing are carried out along with cleaning and bake-out without any air exposure between the processing steps. The system includes a common vacuum chamber in which is located a rotatable wheel-like member which is adapted to move a plurality of individual component sets of a flat pack resonator unit past discretely located processing stations in said chamber whereupon electrode deposition takes place followed by the placement of ceramic covers over a frame containing a resonator element and then to a sealing stage where a pair of hydraulic rams including heating elements effect a metallized bonding of the covers to the frame.

  7. Parametric Resonance in Dynamical Systems

    CERN Document Server

    Nijmeijer, Henk

    2012-01-01

    Parametric Resonance in Dynamical Systems discusses the phenomenon of parametric resonance and its occurrence in mechanical systems,vehicles, motorcycles, aircraft and marine craft, and micro-electro-mechanical systems. The contributors provide an introduction to the root causes of this phenomenon and its mathematical equivalent, the Mathieu-Hill equation. Also included is a discussion of how parametric resonance occurs on ships and offshore systems and its frequency in mechanical and electrical systems. This book also: Presents the theory and principles behind parametric resonance Provides a unique collection of the different fields where parametric resonance appears including ships and offshore structures, automotive vehicles and mechanical systems Discusses ways to combat, cope with and prevent parametric resonance including passive design measures and active control methods Parametric Resonance in Dynamical Systems is ideal for researchers and mechanical engineers working in application fields such as MEM...

  8. Resonance test system

    Science.gov (United States)

    Musial, Walter [Boulder, CO; White, Darris [Superior, CO

    2011-05-31

    An apparatus (10) for applying at least one load to a specimen (12) according to one embodiment of the invention may comprise a mass (18). An actuator (20) mounted to the specimen (12) and operatively associated with the mass (18) moves the mass (18) along a linear displacement path (22) that is perpendicular to a longitudinal axis of the specimen (12). A control system (26) operatively associated with the actuator (20) operates the actuator (20) to reciprocate the mass (18) along the linear displacement path (22) at a reciprocating frequency, the reciprocating frequency being about equal to a resonance frequency of the specimen (12) in a test configuration.

  9. Förster resonance energy transfer, absorption and emission spectra in multichromophoric systems. II. Hybrid cumulant expansion.

    Science.gov (United States)

    Ma, Jian; Moix, Jeremy; Cao, Jianshu

    2015-03-07

    We develop a hybrid cumulant expansion method to account for the system-bath entanglement in the emission spectrum in the multi-chromophoric Förster transfer rate. In traditional perturbative treatments, the emission spectrum is usually expanded with respect to the system-bath coupling term in both real and imaginary time. This perturbative treatment gives a reliable absorption spectrum, where the bath is Gaussian and only the real-time expansion is involved. For the emission spectrum, the initial state is an entangled state of the system plus bath. Traditional perturbative methods are problematic when the excitations are delocalized and the energy gap is larger than the thermal energy, since the second-order expansion cannot predict the displacement of the bath. In the present method, the real-time dynamics is carried out by using the 2nd-order cumulant expansion method, while the displacement of the bath is treated more accurately by utilizing the exact reduced density matrix of the system. In a sense, the hybrid cumulant expansion is based on a generalized version of linear response theory with entangled initial states.

  10. Stark resonances in disordered systems

    International Nuclear Information System (INIS)

    Grecchi, V.; Maioli, M.; Modena Univ.; Sacchetti, A.

    1992-01-01

    By slightly restricting the conditions given by Herbst and Howland, we prove the existence of resonances in the Stark effect of disordered systems (and atomic crystals) for large atomic mean distance. In the crystal case the ladders of resonances have the Wannier behavior for small complex field. (orig.)

  11. A promising magnetic resonance stem cell tracer based on natural biomaterials in a biological system: manganese(II) chelated to melanin nanoparticles.

    Science.gov (United States)

    Liu, Shi-Jie; Wang, Ling-Jie; Qiao, Ying; Zhang, Hua; Li, Li-Ping; Sun, Jing-Hua; He, Sheng; Xu, Wen; Yang, Xi; Cai, Wen-Wen; Li, Jian-Ding; Wang, Bin-Quan; Zhang, Rui-Ping

    2018-01-01

    Melanin and manganese are both indispensable natural substances that play crucial roles in the human body. Melanin has been used as a multimodality imaging nanoplatform for biology science research because of its natural binding ability with metal ions (eg, 64 Cu 2+ , Fe 3+ , and Gd 3+ ). Because of its effects on T1 signal enhancement, Mn-based nanoparticles have been used in magnetic resonance (MR) quantitative cell tracking in vivo. Stem cell tracking in vivo is an essential technology used to characterize engrafted stem cells, including cellular viability, biodistribution, differentiation capacity, and long-term fate. In the present study, manganese(II) ions chelated to melanin nanoparticles [MNP-Mn(II)] were synthesized. The characteristics, stem cell labeling efficiency, and cytotoxicity of the nanoparticles were evaluated. MR imaging of the labeled stem cells in vivo and in vitro were also further performed. In T1 relaxivity (r1), MNP-Mn(II) were significantly more abundant than Omniscan. Bone marrow-derived stem cells (BMSCs) can be labeled easily by coincubating with MNP-Mn(II), suggesting that MNP-Mn(II) had high biocompatibility. Cell Counting Kit-8 assays revealed that MNP-Mn(II) had almost no cytotoxicity when used to label BMSCs, even with a very high concentration (1,600 µg/mL). BMSCs labeled with MNP-Mn(II) could generate a hyperintense T1 signal both in vitro and in vivo, and the hyperintense T1 signal in vivo persisted for at least 28 days. Taken together, our results showed that MNP-Mn(II) possessed many excellent properties for potential quantitative stem cell tracking in vivo.

  12. A promising magnetic resonance stem cell tracer based on natural biomaterials in a biological system: manganese (II chelated to melanin nanoparticles

    Directory of Open Access Journals (Sweden)

    Liu SJ

    2018-03-01

    Full Text Available Shi-Jie Liu,1,2,* Ling-Jie Wang,1,* Ying Qiao,1 Hua Zhang,1 Li-Ping Li,1 Jing-Hua Sun,1 Sheng He,1 Wen Xu,1,2 Xi Yang,1 Wen-Wen Cai,2 Jian-Ding Li,1 Bin-Quan Wang,3 Rui-Ping Zhang2 1Medical Imaging Department, First Clinical Medical College of Shanxi Medical University, Taiyuan, Shanxi, China; 2Imaging Department, Affiliated Tumor Hospital of Shanxi Medical University, Taiyuan, Shanxi, China; 3Department of Otolaryngology, Head & Neck Surgery, The First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China *These authors contributed equally to the paper Background: Melanin and manganese are both indispensable natural substances that play crucial roles in the human body. Melanin has been used as a multimodality imaging nanoplatform for biology science research because of its natural binding ability with metal ions (eg, 64Cu2+, Fe3+, and Gd3+. Because of its effects on T1 signal enhancement, Mn-based nanoparticles have been used in magnetic resonance (MR quantitative cell tracking in vivo. Stem cell tracking in vivo is an essential technology used to characterize engrafted stem cells, including cellular viability, biodistribution, differentiation capacity, and long-term fate.Methods: In the present study, manganese(II ions chelated to melanin nanoparticles [MNP-Mn(II] were synthesized. The characteristics, stem cell labeling efficiency, and cytotoxicity of the nanoparticles were evaluated. MR imaging of the labeled stem cells in vivo and in vitro were also further performed. In T1 relaxivity (r1, MNP-Mn(II were significantly more abundant than Omniscan. Bone marrow-derived stem cells (BMSCs can be labeled easily by coincubating with MNP-Mn(II, suggesting that MNP-Mn(II had high biocompatibility.Results: Cell Counting Kit-8 assays revealed that MNP-Mn(II had almost no cytotoxicity when used to label BMSCs, even with a very high concentration (1,600 µg/mL. BMSCs labeled with MNP-Mn(II could generate a hyperintense T1 signal both in vitro

  13. Belle II production system

    Science.gov (United States)

    Miyake, Hideki; Grzymkowski, Rafal; Ludacka, Radek; Schram, Malachi

    2015-12-01

    The Belle II experiment will record a similar quantity of data to LHC experiments and will acquire it at similar rates. This requires considerable computing, storage and network resources to handle not only data created by the experiment but also considerable amounts of simulated data. Consequently Belle II employs a distributed computing system to provide the resources coordinated by the the DIRAC interware. DIRAC is a general software framework that provides a unified interface among heterogeneous computing resources. In addition to the well proven DIRAC software stack, Belle II is developing its own extension called BelleDIRAC. BelleDIRAC provides a transparent user experience for the Belle II analysis framework (basf2) on various environments and gives access to file information managed by LFC and AMGA metadata catalog. By unifying DIRAC and BelleDIRAC functionalities, Belle II plans to operate an automated mass data processing framework named a “production system”. The Belle II production system enables large-scale raw data transfer from experimental site to raw data centers, followed by massive data processing, and smart data delivery to each remote site. The production system is also utilized for simulated data production and data analysis. Although development of the production system is still on-going, recently Belle II has prepared prototype version and evaluated it with a large scale simulated data production. In this presentation we will report the evaluation of the prototype system and future development plans.

  14. Resonant Effects in Neutral beam Moderation at TJ-II

    International Nuclear Information System (INIS)

    Guasp, J.; Liniers, M.; Fuentes, C.

    1999-01-01

    The structure of fast ion losses in neutral beam moderation at TJ-II is analysed theoretically, in particular the influence of resonant effects and the radial electric field dependence. The direct losses show strong resonant effects when the ratio of the poloidal and toroidal rotation velocities pass near the values -4/3, -2 or 0. These effects are visible as strong maxima on the loss fractions and also as characteristic trajectory behaviours. The delayed losses present resonant effects also, generally at intermediate energies (5 to 20 KeV for 40 keV injection). Near the resonances the population of passing particles in these losses is very high and the loss fraction can equal or even surpass the direct losses. In these delayed losses the particles concentrate along vertical strips on the loss cone diagrams of roughly constant parallel velocity. This parallel velocity increases with the electric field, the loss maxima are reached usually when the pitch and energy of these strips are near the initial injection values. The trapped particle population in these delayed losses is maximal at null electric and decreases with the field intensity for both potential signs. The corresponding final energies are usually low (1 to 5 keV). Except at extreme potentials, where the -4 resonance can appear, no resonant effects are observed for this population. The resonance ordering is similar for all configurations and follows reasonably the predictions of a simple model. The extreme configurations are dominated by the effects of the 0 and -2 resonances, giving very high loss fractions even for null electric field. In contrast the intermediate configurations, near the Reference one, do not present resonant effects and the losses are moderate at low potentials. Only above 2000 v the resonant effects start to appear. (Author) 11 refs

  15. Symmetry and resonance in Hamiltonian systems

    NARCIS (Netherlands)

    Tuwankotta, J.M.; Verhulst, F.

    2000-01-01

    In this paper we study resonances in two degrees of freedom, autonomous, hamiltonian systems. Due to the presence of a symmetry condition on one of the degrees of freedom, we show that some of the resonances vanish as lower order resonances. After giving a sharp estimate of the resonance domain, we

  16. Symmetry and resonance in Hamiltonian systems

    NARCIS (Netherlands)

    Tuwankotta, J.M.; Verhulst, F.

    1999-01-01

    In this paper we study resonances in two degrees of freedom, autonomous, hamiltonian systems. Due to the presence of a symmetry condition on one of the degrees of freedom, we show that some of the resonances vanish as lower order resonances. After determining the size of the resonance domain, we

  17. Characterization system for resonant micro- and nanocantilevers

    DEFF Research Database (Denmark)

    Sandberg, Rasmus Kousholt; Boisen, Anja; Svendsen, Winnie Edith

    2005-01-01

    We present a system for characterization of the resonant properties of micro- and nanocantilever sensors. The system has been constructed as a vacuum chamber with capabilities for controlling environmental conditions such as pressure, temperature, and chemical constituents. Characterization can...... in resonant frequency determination, and demonstrating the importance of resonance characterization in a controlled environment. ©2005 American Institute of Physics...

  18. Enriched vibrational resonance in certain discrete systems

    Indian Academy of Sciences (India)

    We wish to report the occurrence of vibrational resonance in certain discrete systems like sine square map and sine circle map, in a unique fashion, comprising of multiple resonant peaks which pave the way for enrichment. As the systems of our choice are capable of exhibiting vibrational resonance behaviour unlike the ...

  19. Prospective Validation of a Low Rectal Cancer Magnetic Resonance Imaging Staging System and Development of a Local Recurrence Risk Stratification Model: The MERCURY II Study.

    Science.gov (United States)

    Battersby, Nicholas J; How, Peter; Moran, Brendan; Stelzner, Sigmar; West, Nicholas P; Branagan, Graham; Strassburg, Joachim; Quirke, Philip; Tekkis, Paris; Pedersen, Bodil Ginnerup; Gudgeon, Mark; Heald, Bill; Brown, Gina

    2016-04-01

    This study aimed to validate a magnetic resonance imaging (MRI) staging classification that preoperatively assessed the relationship between tumor and the low rectal cancer surgical resection plane (mrLRP). Low rectal cancer oncological outcomes remain a global challenge, evidenced by high pathological circumferential resection margin (pCRM) rates and unacceptable variations in permanent colostomies. Between 2008 and 2012, a prospective, observational, multicenter study (MERCURY II) recruited 279 patients with adenocarcinoma 6 cm or less from the anal verge. MRI assessed the following: mrLRP "safe or unsafe," venous invasion (mrEMVI), depth of spread, node status, tumor height, and tumor quadrant. MRI-based treatment recommendations were compared against final management and pCRM outcomes. Overall pCRM involvement was 9.0% [95% confidence interval (CI), 5.9-12.3], significantly lower than previously reported rates of 30%. Patients with no adverse MRI features and a "safe" mrLRP underwent sphincter-preserving surgery without preoperative radiotherapy, resulting in a 1.6% pCRM rate. The pCRM rate increased 5-fold for an "unsafe" compared with "safe" preoperative mrLRP [odds ratio (OR) = 5.5; 95% CI, 2.3-13.3)]. Posttreatment MRI reassessment indicated a "safe" ymrLRP in 33 of 113 (29.2%), none of whom had ypCRM involvement. In contrast, persistent "unsafe" ymrLRP posttherapy resulted in 17.5% ypCRM involvement. Further independent MRI assessed risk factors were EMVI (OR = 3.8; 95% CI, 1.5-9.6), tumors less than 4.0 cm from the anal verge (OR = 3.4; 95% CI, 1.3-8.8), and anterior tumors (OR = 2.8; 95% CI, 1.1-6.8). The study validated MRI low rectal plane assessment, reducing pCRM involvement and avoiding overtreatment through selective preoperative therapy and rationalized use of permanent colostomy. It also highlights the importance of posttreatment restaging.

  20. Resonance states in disordered systems

    International Nuclear Information System (INIS)

    Bentosela, F.

    1985-06-01

    To study the resonances for the Schroedinger equation of an electron in one dimensional disordered solids submitted to electric field, we use a WKB type ansatz and show that resonance widths so obtained are in good agreement with numerical computations

  1. Resonance Capture and Dynamics of 3-Planet Systems

    Science.gov (United States)

    Charalambous, C.; Martí, J. G.; Beaugé, C.; Ramos, X. S.

    2018-03-01

    We present a series of dynamical maps for fictitious 3-planets systems in initially circular coplanar orbits. These maps have unveiled a rich resonant structure involving two or three planets, as well as indicating possible migration routes from secular to double resonances or pure 3-planet commensurabilities. These structures are then compared to the present-day orbital architecture of observed resonant chains. In a second part of the paper we describe N-body simulations of type-I migration. Depending on the orbital decay timescale, we show that 3-planet systems may be trapped in different combinations of independent commensurabilities: (i) double resonances, (ii) intersection between a 2-planet and a first-order 3-planet resonance, and (iii) simultaneous libration in two first-order 3-planet resonances. These latter outcomes are found for slow migrations, while double resonances are almost always the final outcome in high-density disks. Finally, we discuss an application to the TRAPPIST-1 system. We find that, for low migration rates and planetary masses of the order of the estimated values, most 3-planet sub-systems are able to reach the observed double resonances after following evolutionary routes defined by pure 3-planet resonances. The final orbital configuration shows resonance offsets comparable with present-day values without the need of tidal dissipation. For the 8/5 resonance proposed to dominate the dynamics of the two inner planets, we find little evidence of its dynamical significance; instead, we propose that this relation between mean motions could be a consequence of the interaction between a pure 3-planet resonance and a 2-planet commensurability between planets c and d.

  2. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  3. Proton nuclear magnetic resonance and spectrophotometric studies of nickel(II)-iron(II) hybrid hemoglobins

    International Nuclear Information System (INIS)

    Shibayama, N.; Inubushi, T.; Morimoto, H.; Yonetani, T.

    1987-01-01

    Ni(II)-Fe(II) hybrid hemoglobins, α(Fe) 2 β(Ni) 2 and α(Ni) 2 β(Fe) 2 , have been characterized by proton nuclear magnetic resonance with Ni(II) protoporphyrin IX (Ni-PP) incorporated in apoprotein, which serves as a permanent deoxyheme. α(Fe) 2 β(Ni) 2 , α(Ni) 2 β(Fe) 2 , and NiHb commonly show exchangeable proton resonances at 11 and 14 ppm, due to hydrogen-bonded protons in a deoxy-like structure. Upon binding of carbon monoxide (CO) to α(Fe) 2 β(Ni) 2 , these resonances disappear at pH 6.5 to pH 8.5. On the other hand, the complementary hybrid α(Ni) 2 β(Fe-CO) 2 showed the 11 and 14 ppm resonances at low pH. Upon raising pH, the intensities of both resonances are reduced, although these changes are not synchronized. Electronic absorption spectra and hyperfine-shifted proton resonances indicate that the ligation of CO in the β(Fe) subunits induced changes in the coordination and spin states of Ni-PP in the α subunits. In a deoxy-like structure, the coordination of Ni-PP in the α subunits is predominantly in a low-spin (S = 0) four-coordination state, whereas in an oxy-like structure the contribution of a high-spin (S = 1) five-coordination state markedly increased. Ni-PP in the β subunits always takes a high-spin five-coordination state regardless of solution conditions and the state of ligation in the partner α(Fe) subunits. In the β(Ni) subunits, a significant downfield shift of the proximal histidyl N/sub δ/H resonance and a change in the absorption spectrum of Ni-PP were detected, upon changing the quaternary structure of the hybrid. The chemical shifts were analyzed in terms of the E11-Val methyls vs. the porphyrin rings in hybrid Hbs

  4. Resonances in η-light nucleus systems

    Indian Academy of Sciences (India)

    We locate resonances in -light nucleus elastic scattering using the time delay method. We solve few-body equations within the finite rank approximation in order to calculate the -matrices and hence the time delay for the - 3He and - 4He systems. We find a resonance very close to the threshold in - 3 He elastic ...

  5. Resonances in η-light nucleus systems

    Indian Academy of Sciences (India)

    We locate resonances in η-light nucleus elastic scattering using the time delay method. We solve few-body ... We planned to study the resonances in η-light nuclei systems since the few-body systems can be treated .... In an eigenphase formu- lation of the S-matrix, S = ηe2iδ (with η being the inelasticity factor), one can.

  6. Resonances in few-body systems

    International Nuclear Information System (INIS)

    Afnan, I.R.

    1990-09-01

    It is shown how the resonance poles of the scattering amplitude correspond to eigenstates of the Hamiltonian that is analytical continued into the complex r-space via the dilatation group transformation, and how the corresponding eigenstates satisfy a modified form of the orthogonality condition. As an illustration of the results, examples of resonances in π - d, and α - d scattering as a three-body system are presented. 11 refs., 4 figs

  7. Manganese and the II system in photosynthesis

    International Nuclear Information System (INIS)

    Joyard, Jacques

    1971-01-01

    The evolution during greening of some components of system II of photosynthesis has been followed in plastids extracted from Zea mays grown in the dark. Manganese studies were done by means of neutron activation, electron spin resonance (ESR) was also used in some experiments. Oxygen evolution of isolated plastids was followed by polarography (with a membrane electrode). The evolution of manganese/carotenoids ratio can be divided in three parts. During the first hour of greening, the increase shows an input of Mn in the plastids; then, whereas carotenoids content of those plastids presents no changes, Mn is released in the medium; at last, carotenoids synthesis is parallel to Mn fixation in the plastids, the ratio being constant after 24 hours of greening. From various measurements on chloroplastic manganese, it is shown that the development of system II can be divided in two main phases: during the first one (that is during the first day of light) the components are not yet bound together but the relations become more and more strong. Then, during the last period of the development, the organisation of system II is complete and the transformations of the plastids are parallel to the raise of their activity. (author) [fr

  8. Ion cyclotron resonance heating system on Aditya

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Abstract. An ion cyclotron resonance heating (ICRH) system has been designed, fabricated indigenously and commissioned on Tokamak Aditya. The system has been commissioned to operate between 20·0 and 47·0 MHz at a maximum power of 200 kW continuous wave (CW). Duration of 500 ms is sufficient for operation.

  9. Resonances in the two centers Coulomb system

    Energy Technology Data Exchange (ETDEWEB)

    Seri, Marcello

    2012-09-14

    In this work we investigate the existence of resonances for two-centers Coulomb systems with arbitrary charges in two and three dimensions, defining them in terms of generalized complex eigenvalues of a non-selfadjoint deformation of the two-center Schroedinger operator. After giving a description of the bifurcation of the classical system for positive energies, we construct the resolvent kernel of the operators and we prove that they can be extended analytically to the second Riemann sheet. The resonances are then defined and studied with numerical methods and perturbation theory.

  10. The unsaturated bistable stochastic resonance system.

    Science.gov (United States)

    Zhao, Wenli; Wang, Juan; Wang, Linze

    2013-09-01

    We investigated the characteristics of the output saturation of the classical continuous bistable system (saturation bistable system) and its impact on stochastic resonance (SR). We further proposed a piecewise bistable SR system (unsaturated bistable system) and developed the expression of signal-to-noise ratio (SNR) using the adiabatic approximation theory. Compared with the saturation bistable system, the SNR is significantly improved in our unsaturated bistable SR system. The numerical simulation showed that the unsaturated bistable system performed better in extracting weak signals from strong background noise than the saturation bistable system.

  11. Resonance eigenfunctions in chaotic scattering systems

    Indian Academy of Sciences (India)

    PRAMANA c Indian Academy of Sciences. Vol. 73, No. 3. — journal of. September 2009 physics pp. 543–551. Resonance eigenfunctions in chaotic scattering systems ... particularly convenient model is the baker map because its backward and forward ... One time step of the triadic baker map consists of stretching in.

  12. Scalar resonances as two-quark systems

    Energy Technology Data Exchange (ETDEWEB)

    Shabalin, E.P.

    1985-07-01

    On the basis of a theory with an effective U(3)xU(3)-symmetric chiral Lagrangian it is possible to determine the properties of two-quark scalar mesons and to show that the scalar resonances delta(980) and k(1240) can be treated as P-wave states of the q-barq system.

  13. Resonance eigenfunctions in chaotic scattering systems

    Indian Academy of Sciences (India)

    We study the semiclassical structure of resonance eigenstates of open chaotic systems. We obtain semiclassical estimates for the weight of these states on different regions in phase space. These results imply that the long-lived right (left) eigenstates of the non-unitary propagator are concentrated in the semiclassical limit ħ ...

  14. Resonances in a periodically driven bosonic system

    Science.gov (United States)

    Quelle, Anton; Smith, Cristiane Morais

    2017-11-01

    Periodically driven systems are a common topic in modern physics. In optical lattices specifically, driving is at the origin of many interesting phenomena. However, energy is not conserved in driven systems, and under periodic driving, heating of a system is a real concern. In an effort to better understand this phenomenon, the heating of single-band systems has been studied, with a focus on disorder- and interaction-induced effects, such as many-body localization. Nevertheless, driven systems occur in a much wider context than this, leaving room for further research. Here, we fill this gap by studying a noninteracting model, characterized by discrete, periodically spaced energy levels that are unbounded from above. We couple these energy levels resonantly through a periodic drive, and discuss the heating dynamics of this system as a function of the driving protocol. In this way, we show that a combination of stimulated emission and absorption causes the presence of resonant stable states. This will serve to elucidate the conditions under which resonant driving causes heating in quantum systems.

  15. Characterization of optical systems for the ALPS II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Spector, Aaron D. [Hamburg Univ. (Germany). Inst. fuer Experimentalphsik; Pold, Jan H.; Lindner, Axel [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Baehre, Robin; Willke, Benno [Max-Planck-Institute for Gravitational Physics, Hannover (Germany); Hannover Univ. (Germany). Inst. fuer Gravitationsphysik

    2016-09-15

    ALPS II is a light shining through a wall style experiment that will use the principle of resonant enhancement to boost the conversion and reconversion probabilities of photons to relativistic WISPs. This will require the use of long baseline low-loss optical cavities. Very high power build up factors in the cavities must be achieved in order to reach the design sensitivity of ALPS II. This necessitates a number of different sophisticated optical and control systems to maintain the resonance and ensure maximal coupling between the laser and the cavity. In this paper we report on the results of the characterization of these optical systems with a 20m cavity and discuss the results in the context of ALPS II.

  16. Characterization of optical systems for the ALPS II experiment

    International Nuclear Information System (INIS)

    Spector, Aaron D.; Baehre, Robin; Willke, Benno; Hannover Univ.

    2016-09-01

    ALPS II is a light shining through a wall style experiment that will use the principle of resonant enhancement to boost the conversion and reconversion probabilities of photons to relativistic WISPs. This will require the use of long baseline low-loss optical cavities. Very high power build up factors in the cavities must be achieved in order to reach the design sensitivity of ALPS II. This necessitates a number of different sophisticated optical and control systems to maintain the resonance and ensure maximal coupling between the laser and the cavity. In this paper we report on the results of the characterization of these optical systems with a 20m cavity and discuss the results in the context of ALPS II.

  17. Ultrasensitive and selective detection of mercury (II) in serum based on the gold film sensor using a laser scanning confocal imaging-surface plasmon resonance system in real time

    Science.gov (United States)

    Liu, Sha; Zhang, Hongyan; Liu, Weimin; Wang, Pengfei

    2015-10-01

    Hg2+ ions are one of the most toxic heavy metal ion pollutants, and are caustic and carcinogenic materials with high cellular toxicity. The Hg2+ ions can accumulate in the human body through the food chain and cause serious and permanent damage to the brain with both acute and chronic toxicity. According to the US Environment Protection Agency (EPA) guidelines, Hg2+ ions must be at concentrations below 1 ng/ml (10 nM) in drinking water. If the Hg2+ ions are higher than 2.5 ng/ml in serum, that will bring mercury poisoning. The traditional testing for Hg2+ ions includes atomic absorption, atomic fluorescence, and inductively coupled plasma mass spectrometry. These methods are usually coupled with gas chromatography, high-performance liquid chromatography, and capillary electrophoresis. However, these instrument-based techniques are rather complicated, time-consuming, costly, and unsuitable for online and portable use. An ultrasensitive and selective detection of mercury (II) in serum was investigated using a laser scanning confocal imaging-surface plasmon resonance system (LSCI-SPR). The detection limit was as low as 0.01 ng/ml for Hg2+ ions in fetal calf serum and that is lower than that was required Hg2+ ions must be at concentrations below 1 ng/ml by the US Environment Protection Agency (EPA) guidelines. This sensor was designed on a T-rich, single-stranded DNA (ssDNA)-modified gold film, which can be individually manipulated using specific T-Hg2+-T complex formation. The quenching intensity of the fluorescence images for rhodamine-labeled ssDNA fitted well with the changes in SPR. The changes varied with the Hg2+ ion concentration, which is unaffected by the presence of other metal ions. A good liner relation was got with the coefficients of 0.9116 in 30% fetal calf serums with the linear part over a range of 0.01 ng/ml to10 ng/ml.

  18. The CEBAF separator cavity resonance control system

    International Nuclear Information System (INIS)

    M. Wissmann; C. Hovater; A. Guerra; T. Plawski

    2005-01-01

    The CEBAF energy upgrade will increase the maximum beam energy from 6 GeV to 12 GeV available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three halls. The resulting increase in RF separator cavity gradient and subsequent increase in RF power needed for these higher energies will require the cavities to have active resonance control. Currently, at the present 4 to 6 GeV energies, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW) which is maintained at a constant temperature of 95 Fahrenheit. This approach is no longer feasible and an active resonance control system that controls both water temperature and flow has been designed and built. The system uses a commercial PLC with embedded PID controls to regulate water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately, closed loop control will be maintained by monitoring each cavity's reflected power. This paper describes this system

  19. The CEBAF Separator Cavity Resonance Control System

    CERN Document Server

    Wissmann, Mark J; Hovater, Curt; Plawski, Tomasz

    2005-01-01

    The CEBAF energy upgrade from 6 GeV to 12GeV will increase the range of beam energies available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three experimental halls. Consequently with the increase in RF separator cavity gradient needed for the higher energies, RF power will also increase requiring the cavities to have active resonance control. At the 6 GeV energy, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW), which is maintained at constant temperature of 95o Fahrenheit. This is no longer feasible and an active resonance control system, that controls both water temperature and flow has been built. The system uses a commercial PLC with embedded PID controls to control water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately closed loop control will be maintained by monit...

  20. The LCLS-II LLRF System

    Energy Technology Data Exchange (ETDEWEB)

    DooLittle, Lawrence [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Huang, G. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Ratti, A. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Serrano, C. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Bachimanchi, Ramakrishna [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Hovater, J. Curt [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Babel, S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Hong, B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Van Winkle, D. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Chase, B. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Cullerton, E. [FNAL, Batavia, IL; Varghese, P. [FNAL, Batavia, IL

    2015-09-01

    The SLAC National Accelerator Laboratory is planning an upgrade (LCLS-II) to the Linear Coherent Light Source with a 4 GeV CW superconducting (SCRF) linac. The SCRF linac consists of 35 ILC style cryomodules (eight cavities each) for a total of 280 cavities. Expected cavity gradients are 16 MV/m with a loaded QL of ~ 4x107. The RF system will have 3.8 kW solid state amplifiers driving single cavities. To ensure optimum field stability a single-source single-cavity control system has been chosen. It consists of a precision four-channel cavity receiver and RF stations (Forward, Reflected and Drive signals). In order to regulate the resonant frequency variations of the cavities due to He pressure, the tuning of each cavity is controlled by a Piezo actuator and a slow stepper motor. In addition the system (LLRF-amplifier-cavity) is being modeled and cavity microphonic testing has started. This paper describes the LLRF system under consideration, including recent modeling and cavity tests.

  1. Numerical analysis of resonances induced by s wave neutrons in transmission time-of-flight experiments with a computer IBM 7094 II

    International Nuclear Information System (INIS)

    Corge, Ch.

    1969-01-01

    Numerical analysis of transmission resonances induced by s wave neutrons in time-of-flight experiments can be achieved in a fairly automatic way on an IBM 7094/II computer. The involved computations are carried out following a four step scheme: 1 - experimental raw data are processed to obtain the resonant transmissions, 2 - values of experimental quantities for each resonance are derived from the above transmissions, 3 - resonance parameters are determined using a least square method to solve the over determined system obtained by equalling theoretical functions to the correspondent experimental values. Four analysis methods are gathered in the same code, 4 - graphical control of the results is performed. (author) [fr

  2. Vector resonances at LHC Run II in composite 2HDM

    Energy Technology Data Exchange (ETDEWEB)

    Chiara, Stefano Di [National Institute of Chemical Physics and Biophysics,Rävala 10, 10143 Tallinn (Estonia); Heikinheimo, Matti; Tuominen, Kimmo [Helsinki Institute of Physics, University of Helsinki,P.O. Box 64, FI-000140, Helsinki (Finland); Department of Physics, University of Helsinki,P.O. Box 64, FI-000140, Helsinki (Finland)

    2017-03-02

    We consider a model where the electroweak symmetry breaking is driven by strong dynamics, resulting in an electroweak doublet scalar condensate, and transmitted to the standard model matter fields via another electroweak doublet scalar. At low energies the effective theory therefore shares features with a type-I two Higgs doublet model. However, important differences arise due to the rich composite spectrum expected to contain new vector resonances accessible at the LHC. We carry out a systematic analysis of the vector resonance signals at LHC and find that the model remains viable, but will be tightly constrained by direct searches as the projected integrated luminosity, around 200 fb{sup −1}, of the current run becomes available.

  3. Sensitive metal ions (II) determination with resonance Raman method

    Science.gov (United States)

    Yu, Zhi; Bracero, Lucas A.; Chen, Lei; Song, Wei; Wang, Xu; Zhao, Bing

    2013-03-01

    In this paper, a new proposal for the quantitative evaluation of divalent metal ions (M2+) is developed by the use of the competitive resonance Raman (RR)-based method. Upon excitation with light of the appropriate wavelength (532 nm), a strong electric field is generated that couples with the resonance of the complex (zincon-M2+), increasing the character signals of these complexes, resulting in sensitive detection. Herein, the RR probe, zincon-M2+ complex that the RR intensity gets lower with the decreasing of the M2+ concentration, which leads to the transformation of the Raman information. As a result, by using the proposed RR-based method, we could find the liner calibration curves of Cu2+ and Ni2+, which show the potential in quantitative evaluation of an unknown sample. In addition, the abundant fingerprint information shows that RR leads to the successful analysis of a blended solution, which contains two ions: Cu2+ and Ni2+.

  4. Shimadzu magnetic resonance imaging system, SMT-50

    International Nuclear Information System (INIS)

    Oikawa, Shiro; Nishida, Takayuki; Fujio, Yasuo

    1986-01-01

    The magnetic resonance imaging (MRI) system, as a new modality of medical imaging, has already been put to practical applications on many clinical sites, through which a lot of clinical data has been accumulated. It can offer a powerful new probe of internal anatomy of the human body and its functions. Now that the MRI has established its effectiveness in diagnosis, a really practical MRI system which features high efficiency and economical design with high patient throughput is strongly called for. Introduced in this article is a superconductive magnet MRI system, SMT-50, operating at 5000 Gauss. It has realized an excellent diagnostic capability with such functions as multi-slice multi-echo imaging, high sensitive, surface coil technique and so on. High resolution image display (1024 x 1024 pixcel) unit and separate console system (viewing console and scanning console) will assist high patient throughput. The outline of the SMT-50 and its clinical data are reported here. (author)

  5. Magnetic resonance imaging of the cardiovascular system

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Imai, Hiroshi; Watanabe, Sigeru; Inagaki, Yoshiaki; Tateno, Yukio; Ikehira, Hiroo.

    1990-01-01

    Magnetic resonance imaging (MRI) is a new noninvasive technique for visualization of the cardiovascular system, and is used to evaluate tissue characteristics, cardiac function and blood flow abnormalities, as well as to obtain morphological information. In this paper we presented results of clinical and laboratory research obtained using conventional spin echo MRI with regard to cardiovascular anatomy, tissue characterization and physiology. Furthermore, experience with two new techniques, cine-MRI and volume-selected MR spectroscopy, and their potential clinical usefulness in detecting cardiovascular diseases are documented. (author)

  6. Preheating after multifield inflation with nonminimal couplings. II. Resonance structure

    Science.gov (United States)

    DeCross, Matthew P.; Kaiser, David I.; Prabhu, Anirudh; Prescod-Weinstein, Chanda; Sfakianakis, Evangelos I.

    2018-01-01

    This is the second in a series of papers on preheating in inflationary models comprised of multiple scalar fields coupled nonminimally to gravity. In this paper, we work in the rigid-spacetime approximation and consider field trajectories within the single-field attractor, which is a generic feature of these models. We construct the Floquet charts to find regions of parameter space in which particle production is efficient for both the adiabatic and isocurvature modes, and analyze the resonance structure using analytic and semianalytic techniques. Particle production in the adiabatic direction is characterized by the existence of an asymptotic scaling solution at large values of the nonminimal couplings, ξI≫1 , in which the dominant instability band arises in the long-wavelength limit, for comoving wave numbers k →0 . However, the large-ξI regime is not reached until ξI≥O (100 ). In the intermediate regime, with ξI˜O (1 - 10 ) , the resonance structure depends strongly on wave number and couplings. The resonance structure for isocurvature perturbations is distinct and more complicated than its adiabatic counterpart. An intermediate regime, for ξI˜O (1 - 10 ) , is again evident. For large values of ξI, the Floquet chart consists of densely spaced, nearly parallel instability bands, suggesting a very efficient preheating behavior. The increased efficiency arises from features of the nontrivial field-space manifold in the Einstein frame, which itself arises from the fields' nonminimal couplings in the Jordan frame, and has no analog in models with minimal couplings. Quantitatively, the approach to the large-ξI asymptotic solution for isocurvature modes is slower than in the case of the adiabatic modes.

  7. Magnetic resonance imaging (MRI) in obstetrics. II. Fetal anatomy.

    Science.gov (United States)

    Powell, M C; Worthington, B S; Buckley, J M; Symonds, E M

    1988-01-01

    Magnetic resonance imaging (MRI) was performed in 36 patients at between 10 and 38 weeks gestation to determine the fetal anatomy that could be identified at different gestations. Fetal motion significantly degraded the image quality in the first and second trimesters, but in the final trimester fetal anatomy was clearly demonstrated. T2 weighted sequences showed the fetal brain and lungs to have a high signal intensity. Shorter TR leading to a T1 weighting gave better resolution of the overall anatomy. MRI has revealed the potential for assessment of lung maturity and the growth-retarded fetus.

  8. FINE-STRUCTURE Fe II* EMISSION AND RESONANT Mg II EMISSION IN z ∼ 1 STAR-FORMING GALAXIES

    International Nuclear Information System (INIS)

    Kornei, Katherine A.; Shapley, Alice E.; Martin, Crystal L.; Coil, Alison L.; Lotz, Jennifer M.; Weiner, Benjamin J.

    2013-01-01

    We present a study of the prevalence, strength, and kinematics of ultraviolet Fe II and Mg II emission lines in 212 star-forming galaxies at z ∼ 1 selected from the DEEP2 survey. We find Fe II* emission in composite spectra assembled on the basis of different galaxy properties, indicating that Fe II* emission is common at z ∼ 1. In these composites, Fe II* emission is observed at roughly the systemic velocity. At z ∼ 1, we find that the strength of Fe II* emission is most strongly modulated by dust attenuation, and is additionally correlated with redshift, star formation rate, and [O II] equivalent width, such that systems at higher redshifts with lower dust levels, lower star formation rates, and larger [O II] equivalent widths show stronger Fe II* emission. We detect Mg II emission in at least 15% of the individual spectra and we find that objects showing stronger Mg II emission have higher specific star formation rates, smaller [O II] linewidths, larger [O II] equivalent widths, lower dust attenuations, and lower stellar masses than the sample as a whole. Mg II emission strength exhibits the strongest correlation with specific star formation rate, although we find evidence that dust attenuation and stellar mass also play roles in the regulation of Mg II emission. Future integral field unit observations of the spatial extent of Fe II* and Mg II emission in galaxies with high specific star formation rates, low dust attenuations, and low stellar masses will be important for probing the morphology of circumgalactic gas

  9. RF Coupler Design for the TRIUMF ISAC-II Superconducting Quarter Wave Resonator

    CERN Document Server

    Poirier, R L; Harmer, P; Laxdal, R E; Mitra, A K; Sekatchev, I; Waraich, B; Zvyagintsev, V

    2004-01-01

    An RF Coupler for the ISAC-II medium beta (β=0.058 and 0.071) superconducting quarter wave resonators was designed and tested at TRIUMF. The main goal of this development was to achieve stable operation of superconducting cavities at high acceleration gradients and low thermal load to the helium refrigeration system. The cavities will operate at 6 MV/m acceleration gradient in overcoupled mode at a forward power 200 W at 106 MHz. The overcoupling provides ±20 Hz cavity bandwidth, which improves the stability of the RF control system for fast helium pressure fluctuations, microphonics and environmental noise. Choice of materials, cooling with liquid nitrogen, aluminum nitride RF window and thermal shields insure a small thermal load on the helium refrigeration system by the Coupler. An RF finger contact which causedμdust in the coupler housing was eliminated without any degradation of the coupler performance. RF and thermal calculations, design and test results on the coupler are p...

  10. NSLS-II Radio Frequency Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rose J.; Gao F.; Goel, A.; Holub, B.; Kulpin, J.; Marques, C.; Yeddulla, M.

    2015-05-03

    The National Synchrotron Light Source II is a 3 GeV X-ray user facility commissioned in 2014. The NSLS-II RF system consists of the master oscillator, digital low level RF controllers, linac, booster and storage ring RF sub-systems, as well as a supporting cryogenic system. Here we will report on RF commissioning and early operation experience of the system.

  11. Electronic spin resonance quantitative analysis of Mn(II) complexes anti oxidative activity using phosphate or organic buffer

    Energy Technology Data Exchange (ETDEWEB)

    Souchard, J.P.; Massol, M.; Nepveu, F. [Toulouse-3 Univ., 31 (France)

    1996-01-01

    Superoxide anion is implicated in the pathogenesis of several human diseases including ischaemia, atherosclerosis and inflammation when molecular or enzymatic antioxidant systems cannot regulate its formation. In order to investigate superoxide dismutase (SOD) mimics, a method using Electron Spin Resonance (ESR) has been developed to quantify anti-oxidative activities of Mn(II) compounds. The acetaldehyde / xanthine oxidase system produced superoxide anion and the 5,5-dimethyl-I-pyroline-N-oxide (DMPO) was used as spin trap. The complexing properties of the usual phosphate buffer towards Mn{sup 2+} being not negligible comparatively to those of the studied ligands, activities of free ligands and Mn(II) complexes have been compared according to the buffer, phosphate or organic. (Authors). 7 refs., 1 tab., 2 figs.,.

  12. Gold nanorods for surface Plasmon resonance detection of mercury (II) in flow injection analysis.

    Science.gov (United States)

    Trieu, Khang; Heider, Emily C; Brooks, Scott C; Barbosa, Fernando; Campiglia, Andres D

    2014-10-01

    This article investigates the flow injection analysis of mercury (II) ions in tap water samples via surface Plasmon resonance detection. Quantitative analysis of mercury (II) is based on the chemical interaction of metallic mercury with gold nanorods immobilized on a glass substrate. A new flow cell design is presented with the ability to accommodate the detecting substrate in the sample compartment of commercial spectrometers. Two alternatives are here considered for mercury (II) detection, namely stop-flow and continuous flow injection analysis modes. The best limit of detection (2.4 ng mL(-1)) was obtained with the continuous flow injection analysis approach. The accurate determination of mercury (II) ions in samples of unknown composition is demonstrated with a fortified tap water sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Faint emission features in the Mg II resonance-line wings. [in solar spectra

    Science.gov (United States)

    Allen, M. S.; Mcallister, H. C.

    1977-01-01

    Data obtained with a rocket-borne echelle spectrograph are presented which indicate the presence of three faint emission features deep in the cores of the Mg II h and k resonance-line wings in the solar Fraunhofer spectrum. Results of wavelength measurements are discussed, and the relative intensities of the emission features are examined. It is tentatively suggested that the first feature be identified with the Fe II line at 2797.037 A, the second feature is probably the V II line at 2803.469 A, and the third feature may originate in Fe II emission at 2804.021 A. Possible emission mechanisms are proposed, and it is concluded that the detected features may be of potential diagnostic value for the analysis of depth variations of temperature and velocity in the lower chromosphere as well as for solar and possibly stellar spectroscopy.

  14. Rabi resonance in spin systems: theory and experiment.

    Science.gov (United States)

    Layton, Kelvin J; Tahayori, Bahman; Mareels, Iven M Y; Farrell, Peter M; Johnston, Leigh A

    2014-05-01

    The response of a magnetic resonance spin system is predicted and experimentally verified for the particular case of a continuous wave amplitude modulated radiofrequency excitation. The experimental results demonstrate phenomena not previously observed in magnetic resonance systems, including a secondary resonance condition when the amplitude of the excitation equals the modulation frequency. This secondary resonance produces a relatively large steady state magnetisation with Fourier components at harmonics of the modulation frequency. Experiments are in excellent agreement with the theoretical prediction derived from the Bloch equations, which provides a sound theoretical framework for future developments in NMR spectroscopy and imaging. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Nuclear Magnetic Resonance Trackbed Moisture Sensor System

    Science.gov (United States)

    2018-02-01

    In this initial phase, conducted from March 2015 through December 2016, Vista Clara and its subcontractor Zetica Rail successfully developed and tested a man-portable, non-invasive spot-check nuclear magnetic resonance (NMR) moisture sensor that dire...

  16. Hemophilic arthropathy. A scoring system for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soler, R.; Rodriguez, E.; Marini, M. [Department of Radiology, Hospital Juan Canalejo, Coruna (Spain); Lopez-Fernandez, F. [Department of Hematology, Hospital Juan Canalejo, Coruna (Spain)

    2002-04-01

    The aim of this study was to define a system for scoring hemophilic arthropathy (HA) based on MR findings, providing for objective evaluation of the degree of joint involvement and evolution after on-demand administration of FVIII substitutional therapy or prophylactic treatment. A total of 133 MR examinations (89 basal and 44 during follow-up) were performed in 25 patients. Patients were divided in two groups depending on the therapy received and the length of time that the disease had been evolving at the start of the study. Group I was composed of 10 patients with secondary prophylaxis and group II was composed by 15 treated on demand. T1-weighted and T2*-weighted images performed on a 0.5-T unit were prospectively evaluated. The joint involvement was established on a scale of 0 (no abnormalities), I (minimal amount of hemosiderin), II (large amount of hemosiderin and isolated cartilaginous erosion), III (cartilage destruction, bone erosions, and subchondral cysts) to IV (large internal joint derangement, secondary osteoarthritis and/or ankylosis). At basal MR examination, patients of group I showed no abnormalities (n=28, 75.6%), grade I (n=3), and grade II (n=6) of HA. Patients of group II corresponded to MR grades III (n=21) and IV (n=11) of HA. The MR follow-up showed improvement in three joints of group I and worsening in 5 joints in group I and 2 joints in group II. Early signs of HA were detected in 10 joints with MR imaging but were underestimated on plain radiographs. Advanced degrees of HA were classified as severe under both imaging techniques. Magnetic resonance is the preferred imaging technique to assess HA. The earliest signs of joint damage, detected by MR, are overlooked by plain radiography. The MR scoring system can be used for evaluating HA. Follow-up MR should be performed to evaluate regression or worsening of the abnormalities, primarily in the case of patients with prophylaxis who usually suffer normal or early joint involvement not

  17. Hemophilic arthropathy. A scoring system for magnetic resonance imaging

    International Nuclear Information System (INIS)

    Soler, R.; Rodriguez, E.; Marini, M.; Lopez-Fernandez, F.

    2002-01-01

    The aim of this study was to define a system for scoring hemophilic arthropathy (HA) based on MR findings, providing for objective evaluation of the degree of joint involvement and evolution after on-demand administration of FVIII substitutional therapy or prophylactic treatment. A total of 133 MR examinations (89 basal and 44 during follow-up) were performed in 25 patients. Patients were divided in two groups depending on the therapy received and the length of time that the disease had been evolving at the start of the study. Group I was composed of 10 patients with secondary prophylaxis and group II was composed by 15 treated on demand. T1-weighted and T2*-weighted images performed on a 0.5-T unit were prospectively evaluated. The joint involvement was established on a scale of 0 (no abnormalities), I (minimal amount of hemosiderin), II (large amount of hemosiderin and isolated cartilaginous erosion), III (cartilage destruction, bone erosions, and subchondral cysts) to IV (large internal joint derangement, secondary osteoarthritis and/or ankylosis). At basal MR examination, patients of group I showed no abnormalities (n=28, 75.6%), grade I (n=3), and grade II (n=6) of HA. Patients of group II corresponded to MR grades III (n=21) and IV (n=11) of HA. The MR follow-up showed improvement in three joints of group I and worsening in 5 joints in group I and 2 joints in group II. Early signs of HA were detected in 10 joints with MR imaging but were underestimated on plain radiographs. Advanced degrees of HA were classified as severe under both imaging techniques. Magnetic resonance is the preferred imaging technique to assess HA. The earliest signs of joint damage, detected by MR, are overlooked by plain radiography. The MR scoring system can be used for evaluating HA. Follow-up MR should be performed to evaluate regression or worsening of the abnormalities, primarily in the case of patients with prophylaxis who usually suffer normal or early joint involvement not

  18. LHC II system sensitivity to magnetic fluids

    CERN Document Server

    Cotae, Vlad

    2005-01-01

    Experiments have been designed to reveal the influences of ferrofluid treatment and static magnetic field exposure on the photosynthetic system II, where the light harvesting complex (LHC II) controls the ratio chlorophyll a/ chlorophyll b (revealing, indirectly, the photosynthesis rate). Spectrophotometric measurement of chlorophyll content revealed different influences for relatively low ferrofluid concentrations (10-30 mul/l) in comparison to higher concentrations (70-100 mul/l). The overlapped effect of the static magnetic field shaped better the stimulatory ferrofluid action on LHC II system in young poppy plantlets.

  19. Special resonances in two- and three-cluster systems

    International Nuclear Information System (INIS)

    Orlowski, M.

    1979-01-01

    In the framework of Schmid's N-cluster theory the resonance theory of Wildermuth-Benoehr is extended to three clusters. This three-cluster resonance model is solved in a mathematically exact formalism. The main topic of this formalism is the asymptotic behaviour of the full three-body-resolvent in the differential directions of the six-dimensional position space of the Jacobi coordinates. The scattering amplitudes and cross sections in all two-body channels and breakup are explicitly presented. Furthermore a very illustrative kinematical three-body model, the so called 'three-body-neb', is developed. Special regards in this connection are devoted to the analysis of possible interference possibilities of the main three-body-resonance with other resonance types of the three-body model. In a further section the Pauli-resonances are studied i) in the Wildermuth resonating group theory, ii) in Schmid's simulation models. It is shown under which circumstances Pauli-resonances may be positive energy bound states. (orig./HSI) [de

  20. Multiple systems atrophy: Differentiation and findings by Magnetic resonance

    International Nuclear Information System (INIS)

    Vargas Velez, Sergio Alberto; Alzate Betancur, Catalina Maria

    2006-01-01

    Multiple system atrophy (MSA) is a neuro degenerative disorder of undetermined cause, characterized clinically by Parkinson's, autonomic, cerebellar or pyramidal sing and symptoms. lts differentiation from Parkinson's disease may be difficult, mainly in the early stages owing to overlapping features. Magnetic resonance imaging has demonstrated usefulness in MSA diagnosis and in differentiation with Parkinson's disease. One case with magnetic resonance findings is described

  1. Integrated Analysis of Piezoelectric Resonators as Components of Electronic Systems

    Science.gov (United States)

    2015-09-07

    system. Purpose: Calculating free vibration frequencies and modes of AT- or SC-cut bi-convex or plano -convex quartz resonators, either...electrode thickness. Rc — radius of curvature of the convex surface of a plano -convex resonator, or half of the radius of curvature of the convex

  2. Resonant Auger studies of metallic systems

    International Nuclear Information System (INIS)

    Coulthard, I.; Antel, W. J. Jr.; Frigo, S. P.; Freeland, J. W.; Moore, J.; Calaway, W. S.; Pellin, M. J.; Mendelsohn, M.; Sham, T. K.; Naftel, S. J.

    2000-01-01

    Results of resonant Auger spectroscopy experimental are presented for Cu, Co, and oxidized Al. Sublifetime narrowing of Auger spectra and generation of sublifetime narrowed absorption spectra constructed from Auger yield measurements were observed. Resonant Auger yields are used to identify three chemical states of oxidized Al. Partial absorption yield spectra were derived giving detailed electronic information and thickness information for the various chemical states of the bulk metal, the passivating aluminum oxide layer, and the metal-oxide interface region. In addition, the total absorption yield spectrum for the oxidized Al sample was constructed from the partial yield data, supporting the consistency of our method. (c) 2000 American Vacuum Society

  3. Optical Navigation System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is for a flexible navigation system for deep space operations that does not require GPS measurements. The navigation solution is computed using an...

  4. Thioaptamer Diagnostic System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) in partnership with Sandia National Laboratories will develop a Thioaptamer Diagnostic System (TDS) in response to Topic X10.01 Reusable...

  5. Handbook of power systems II

    Energy Technology Data Exchange (ETDEWEB)

    Rebennack, Steffen [Colorado School of Mines, Golden, CO (United States). Div. of Economics and Business; Pardalos, Panos M. [Florida Univ., Gainesville, FL (United States). Dept. of Industrial and Systems Engineering; Pereira, Mario V.F. [Centro Empresarial Rio Praia de Botafogo, Rio de Janeiro (Brazil); Iliadis, Niko A. (eds.) [EnerCoRD, Athens (Greece)

    2010-07-01

    Energy is one of the world's most challenging problems, and power systems are an important aspect of energy related issues. This handbook contains state-of-the-art contributions on power systems modeling and optimization. The book is separated into two volumes with six sections, which cover the most important areas of energy systems. The first volume covers the topics operations planning and expansion planning while the second volume focuses on transmission and distribution modeling, forecasting in energy, energy auctions and markets, as well as risk management. The contributions are authored by recognized specialists in their fields and consist in either state-of-the-art reviews or examinations of state-of-the-art developments. The articles are not purely theoretical, but instead also discuss specific applications in power systems. (orig.)

  6. Particle Systems and PDEs II

    CERN Document Server

    Soares, Ana

    2015-01-01

    This book focuses on mathematical problems concerning different applications in physics, engineering, chemistry and biology. It covers topics ranging from interacting particle systems to partial differential equations (PDEs), statistical mechanics and dynamical systems. The purpose of the second meeting on Particle Systems and PDEs was to bring together renowned researchers working actively in the respective fields, to discuss their topics of expertise and to present recent scientific results in both areas. Further, the meeting was intended to present the subject of interacting particle systems, its roots in and impacts on the field of physics, and its relation with PDEs to a vast and varied public, including young researchers. The book also includes the notes from two mini-courses presented at the conference, allowing readers who are less familiar with these areas of mathematics to more easily approach them. The contributions will be of interest to mathematicians, theoretical physicists and other researchers...

  7. SOUL System Maturation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Busek Co. Inc. proposes to advance the maturity of an innovative Spacecraft on Umbilical Line (SOUL) System suitable for a wide variety of applications of interest...

  8. Calculated Resonance Line Profiles of [Mg II], [C II], and [Si IV] in the Solar Atmosphere

    Science.gov (United States)

    Avrett, E.; Landi, E.; McKillop, S.

    2013-12-01

    NASA's Interface Region Imaging Spectrograph space mission, launched 2013 June 27, is intended to study the structure of the solar chromosphere and the transition region between the chromosphere and corona. The spectral lines to be observed include the Mg II k line at 2796.5 Å, the C II 1334.5 Å line, and the Si IV line at 1393.8 Å, which are formed in the middle chromosphere, the upper chromosphere, and the lower transition region, respectively. Here we calculate the profiles of these lines from four models of the solar atmosphere, intended to represent the faint and mean internetwork, a network lane, and bright network. We show how the profiles change from the center of the solar disk toward the limb of the Sun and in response to outflows and inflows. These results are intended to cover the range of expected quiet-Sun observations and assist in their interpretation. We expect that the observations will lead to improvements in the models, which can then be used to estimate the required non-radiative heating in the different regions.

  9. Calculated resonance line profiles of [Mg II], [C II], and [Si IV] in the solar atmosphere

    International Nuclear Information System (INIS)

    Avrett, E.; McKillop, S.; Landi, E.

    2013-01-01

    NASA's Interface Region Imaging Spectrograph space mission, launched 2013 June 27, is intended to study the structure of the solar chromosphere and the transition region between the chromosphere and corona. The spectral lines to be observed include the Mg II k line at 2796.5 Å, the C II 1334.5 Å line, and the Si IV line at 1393.8 Å, which are formed in the middle chromosphere, the upper chromosphere, and the lower transition region, respectively. Here we calculate the profiles of these lines from four models of the solar atmosphere, intended to represent the faint and mean internetwork, a network lane, and bright network. We show how the profiles change from the center of the solar disk toward the limb of the Sun and in response to outflows and inflows. These results are intended to cover the range of expected quiet-Sun observations and assist in their interpretation. We expect that the observations will lead to improvements in the models, which can then be used to estimate the required non-radiative heating in the different regions.

  10. Resonances in η-light nucleus systems

    Indian Academy of Sciences (India)

    2Departamento de Fisica, Universidad de los Andes, Bogota, Colombia. E-mail: kanchanp@magnum.barc.ernet.in. Abstract. We locate resonances in η-light nucleus elastic scattering using the time delay method. We solve few-body equations within the finite rank approximation in order to calculate the t-matrices and hence ...

  11. Enriched vibrational resonance in certain discrete systems

    Indian Academy of Sciences (India)

    Corresponding author. E-mail: philominathan@gmail.com ... vibrational resonance behaviour unlike the earlier reports, they are taken for investigation and the necessary numerical and analytical results are ..... quasiperiodic route to chaos instead of period-doubling route. The effect of perturbation in the destruction of ...

  12. Positrons in biomolecular systems. II

    International Nuclear Information System (INIS)

    Glass, J.C.; Graf, G.; Costabal, H.; Ewert, D.H.; English, L.

    1982-01-01

    Pickoff-annihilation parameters, as related to the free volume model, are shown to be indicators of structural fluctuations in membranes and membrane bound proteins. Nitrous oxide anesthetic induces lateral rigidity in a membrane, and an anesthetic mechanism is suggested. Conformational changes of (Na + ,K + )ATPase in natural membrane are observed with ATP and Mg-ion binding. New positron applications to active transport and photosynthetic systems are suggested. (Auth.)

  13. Design of Wireless Readout System for Resonant Gas Sensors

    OpenAIRE

    S. Mohamed Rabeek; Mi Kyoung Park; M. Annamalai Arasu

    2016-01-01

    This paper presents a design of a wireless read out system for tracking the frequency shift of the polymer coated piezoelectric micro electromechanical resonator due to gas absorption. The measure of this frequency shift indicates the percentage of a particular gas the sensor is exposed to. It is measured using an oscillator and an FPGA based frequency counter by employing the resonator as a frequency determining element in the oscillator. This system consists of a Gas Sensing Wireless Readou...

  14. Stability Limits in Resonant Planetary Systems

    OpenAIRE

    Barnes, Rory; Greenberg, Richard

    2007-01-01

    The relationship between the boundaries for Hill and Lagrange stability in orbital element space is modified in the case of resonantly interacting planets. Hill stability requires the ordering of the planets to remain constant while Lagrange stability also requires all planets to remain bound to the central star. The Hill stability boundary is defined analytically, but no equations exist to define the Lagrange boundary, so we perform numerical experiments to estimate the location of this boun...

  15. Scalable high-performance algorithm for the simulation of exciton-dynamics. Application to the light harvesting complex II in the presence of resonant vibrational modes

    DEFF Research Database (Denmark)

    Kreisbeck, Christoph; Kramer, Tobias; Aspuru-Guzik, Alán

    2014-01-01

    the exciton dynamics within a density-matrix formalism are known, but are restricted to small systems with less than ten sites due to their computational complexity. To study the excitonic energy transfer in larger systems, we adapt and extend the exact hierarchical equation of motion (HEOM) method to various...... high-performance many-core platforms using the Open Compute Language (OpenCL). For the light-harvesting complex II (LHC II) found in spinach, the HEOM results deviate from predictions of approximate theories and clarify the time-scale of the transfer-process. We investigate the impact of resonantly...

  16. Computer control system of TARN-II

    International Nuclear Information System (INIS)

    Watanabe, S.

    1990-01-01

    This report describes the present status and future plane of TARN-II computer control system. At present, the microcomputer M-16 is used as the main control computer to regulate the 64 kinds of power supplies coupled with the serial CAMAC interface system. An excitation control of the main ring magnets is performed with the aid of self-learn technique to optimize the tracking error among them. An Rf pattern control is also performed with the microcomputer as well as the main ring control system. New computer system linked with the Ethernet is planed to develop the computing power and portability of the present control system. (author)

  17. Upgrading of TARN-II vacuum system

    International Nuclear Information System (INIS)

    Chida, K.; Arakaki, Y.; Yoshizawa, M.; Tomizawa, M.; Tanabe, T.; Katayama, I.

    1994-01-01

    Ion pumps and titanium getter pumps have been increased nearly twice in the TARN-II. The pumping speed per unit length is now improved up to 2/3 times that of TARN-I. An average vacuum pressure of 10 -11 Torr order has been achieved at beam time. Performance of the system after the upgrading is reported. (author)

  18. Ring resonator systems to perform optical communication enhancement using soliton

    CERN Document Server

    Amiri, Iraj Sadegh

    2014-01-01

    The title explain new technique of secured and high capacity optical communication signals generation by using the micro and nano ring resonators. The pulses are known as soliton pulses which are more secured due to having the properties of chaotic and dark soliton signals with ultra short bandwidth. They have high capacity due to the fact that ring resonators are able to generate pulses in the form of solitons in multiples and train form. These pulses generated by ring resonators are suitable in optical communication due to use the compact and integrated rings system, easy to control, flexibi

  19. 239Pu Resonance Evaluation for Thermal Benchmark System Calculations

    Science.gov (United States)

    Leal, L. C.; Noguere, G.; de Saint Jean, C.; Kahler, A. C.

    2014-04-01

    Analyses of thermal plutonium solution critical benchmark systems have indicated a deficiency in the 239Pu resonance evaluation. To investigate possible solutions to this issue, the Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) Working Party for Evaluation Cooperation (WPEC) established Subgroup 34 to focus on the reevaluation of the 239Pu resolved resonance parameters. In addition, the impacts of the prompt neutron multiplicity (νbar) and the prompt neutron fission spectrum (PFNS) have been investigated. The objective of this paper is to present the results of the 239Pu resolved resonance evaluation effort.

  20. Non-destructive assay of EBR-II blanket elements using resonance transmission analysis

    International Nuclear Information System (INIS)

    Klann, R.T.; Poenitz, W.P.

    1998-01-01

    Resonance transmission analysis utilizing a faltered reactor beam was examined as a means of determining the 239 Pu content in Experimental Breeder Reactor-II depleted uranium blanket elements. The technique uses cadmium and gadolinium falters along with a 239 Pu fission chamber to isolate the 0.3 eV resonance in 239 Pu. In the energy range of this resonance (0.1 eV to 0.5 ev), the total microscopic cross-section of 239 Pu is significantly greater than the cross-sections of 238 U and 235 U. This large difference allows small changes in the 239 Pu content of a sample to result in large changes in the mass signal response. Tests with small stacks of depleted uranium and 239 Pu foils indicate a significant change in response based on the 239 Pu content of the foil stack. In addition, the tests indicate good agreement between the measured and predicted values of 239 Pu up to approximately two weight percent

  1. Stochastic resonance in overdamped systems with fractional power nonlinearity

    Science.gov (United States)

    Yang, Jianhua; Sanjuán, Miguel A. F.; Chen, Pengpeng; Liu, Houguang

    2017-10-01

    The stochastic resonance phenomenon in overdamped systems with fractional power nonlinearity is thoroughly investigated. The first kind of nonlinearity is a general fractional power function. The second kind of nonlinearity is a fractional power function with deflection. For the first case, the response is clearly divergent for some fractional exponent values. The curve of the spectral amplification factor versus the fractional exponent presents some discrete regions. For the second case, the response will not be divergent for any fractional exponent value. The spectral amplification factor decreases with the increase in the fractional exponent. For both cases, the nonlinearity is the necessary ingredient to induce stochastic resonance. However, it is not the sufficient cause to amplify the weak signal. On the one hand, the noise cannot induce stochastic resonance in the corresponding linear system. On the other hand, the spectral amplification factor of the nonlinear system is lower than that of the corresponding linear system. Through the analysis carried out in this paper, we are able to find that the system with fractional deflection nonlinearity is a better stochastic resonance system, especially when an appropriate exponent value is chosen. The results in this paper might have a certain reference value for signal processing problems in relation with the stochastic resonance method.

  2. The metacompiler system META-II/X

    International Nuclear Information System (INIS)

    Kneis, W.

    1975-03-01

    It is the objective of this work to demonstrate by the properties of the META-II/X system and concrete compiler implementation for IML that a simple and universally applicable symbol processor allows to develop in a very easy manner precompilers for problem oriented languages. The main feature consists in the fact that no auxiliary routines coded manually had to be added for special implementation. The translation of IML is exclusively defined by the compiler description written in the META language. As a whole, META-II/X proves to be a system which is relatively convenient to handle in automating the translation of explicit languages. The decisive point is the choise of an assembler language as target language allowing to transfer to the assembler level references not completely resolved. Implementation includes the possibility of an uncomplicated transfer of the whole system inclusive of the internal compiler representations. (orig.) [de

  3. Numerical analysis of resonances induced by s wave neutrons in transmission time-of-flight experiments with a computer IBM 7094 II; Methodes d'analyse des resonances induites par les neutrons s dans les experiences de transmission par temps de vol et automatisation de ces methodes sur ordinateur IBM 7094 II

    Energy Technology Data Exchange (ETDEWEB)

    Corge, Ch. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-01-01

    Numerical analysis of transmission resonances induced by s wave neutrons in time-of-flight experiments can be achieved in a fairly automatic way on an IBM 7094/II computer. The involved computations are carried out following a four step scheme: 1 - experimental raw data are processed to obtain the resonant transmissions, 2 - values of experimental quantities for each resonance are derived from the above transmissions, 3 - resonance parameters are determined using a least square method to solve the over determined system obtained by equalling theoretical functions to the correspondent experimental values. Four analysis methods are gathered in the same code, 4 - graphical control of the results is performed. (author) [French] L'automatisation, sur ordinateur IBM 7094/II, de l'analyse des resonances induites par les neutrons s dans les experiences de transmission par temps de vol a ete accomplie en la decomposant selon un schema articule en quatre phases: 1 - le traitement des donnees experimentales brutes pour obtenir les transmissions interfero-resonnantes, 2 - la determination des grandeurs d'analyse a partir des transmissions precedentes, 3 - l'analyse proprement dite des resonances dont les parametres sont obtenus par la resolution d'un systeme surabondant. Quatre methodes d'analyse sont groupees en un meme programme, 4 - la procedure de verification graphique. (auteur)

  4. NSLS-II booster timing system

    International Nuclear Information System (INIS)

    Cheblakov, P.; Karnaev, S.; De Long, J.

    2012-01-01

    NSLS-II light source includes the main storage ring with beam lines and injection part consisting of 200 MeV linac, a full-energy 3 GeV booster synchrotron and two transport lines. The booster timing system is a part of NSLS-II timing system which uses hardware from MicroResearch Finland: Event Generator (EVG) and Event Receivers (EVRs). The booster timing is based on the events coming from NSLS-II EVG: 'Pre-Injection', 'Injection', 'Pre-Extraction', 'Extraction'. These events are referenced to the selected RF bucket of the storage ring and correspond to the first RF bucket of the booster. EVRs provide triggers both for the injection and the extraction pulse devices. EVRs also provide the timing of booster cycle operation and generation of events for cycle-to-cycle updates of pulsed and ramping parameters, and synchronization of the booster beam instrumentation devices. This paper describes the final design of the booster timing system. The timing system functional diagrams and block diagram are presented. (authors)

  5. LCLS-II CRYOMODULE TRANSPORT SYSTEM TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Daly, Edward F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); McGee, Michael W. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2018-04-01

    The Cryomodules (CM) for the Linear Coherent Light Source II (LCLS-II) will be shipped to SLAC (Menlo Park, California) from JLab (Newport News, Virginia) and FNAL (Batavia, Illinois). A transportation system has been designed and built to safely transport the CMs over the road. It uses an array of helical isolator springs to attenuate shocks on the CM to below 1.5g in all directions. The system rides on trailers equipped with Air-Ride suspension, which attenuates vibration loads. The prototype LCLS-II CM (pCM) was driven 750 miles to test the transport system; shock loggers recorded the shock attenuation on the pCM and vacuum gauges were used to detect any compromises in beamline vacuum. Alignment measurements were taken before and after the trip to check whether cavity positions had shifted beyond the ± 0.2mm spec. Passband frequencies and cavity gradients were measured at 2K at the Cryomodule Test Facility (CMTF) at JLab to identify any degradation of CM performance after transportation. The transport system was found to have safely carried the CM and is cleared to begin shipments from JLab and FNAL to SLAC.

  6. Resonance

    DEFF Research Database (Denmark)

    Petersen, Nils Holger

    2014-01-01

    A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice.......A chapter in a book about terminology within the field of medievalism: the chapter discusses the resonance of medieval music and ritual in modern (classical) music culture and liturgical practice....

  7. PEP-II RF feedback system simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tighe, R. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    A model containing the fundamental impedance of the PEP-II cavity along with the longitudinal beam dynamics and RF feedback system components is in use. It is prepared in a format allowing time-domain as well as frequency-domain analysis and full graphics capability. Matlab and Simulink are control system design and analysis programs (widely available) with many built-in tools. The model allows the use of compiled C-code modules for compute intensive portions. We desire to represent as nearly as possible the components of the feedback system including all delays, sample rates and applicable nonlinearities. (author)

  8. Statistics of resonances in one-dimensional continuous systems

    Indian Academy of Sciences (India)

    pp. 565–572. Statistics of resonances in one-dimensional continuous systems. JOSHUA FEINBERG. Physics Department, University of Haifa at Oranim, Tivon 36006, Israel and ... dimensional continuous open system. The disordered .... due to this integration backwards, f(x, k) can only depend on values of V (y) with y>x.

  9. MADOCA II data acquisition and storage system

    International Nuclear Information System (INIS)

    Yamashita, Akihiro; Kano, Masahiro; Sakai, Hisanobu

    2013-01-01

    In SPring-8, we are constructing MADOCA II, next generation accelerator control framework. It will be installed in the spring of 2014. We describe the part of the data acquisition and the storage system of MADOCA II. MADOCA was built on the bases of ONC-RPC for communication between processes and a relational database for data management. We designed the new framework with the long experience on MADOCA. We employ Zeromq messages packed by Messagepack for communication. NoSQL databases, Redis and Apache Cassandra, store log data. We obtained a high performance, highly reliable, well scalable and flexible data management system. In this paper, we will discuss requirements, design, implementation and the result of the long run test. (author)

  10. Space Acceleration Measurement System-II

    Science.gov (United States)

    Foster, William

    2009-01-01

    Space Acceleration Measurement System (SAMS-II) is an ongoing study of the small forces (vibrations and accelerations) on the ISS that result from the operation of hardware, crew activities, as well as dockings and maneuvering. Results will be used to generalize the types of vibrations affecting vibration-sensitive experiments. Investigators seek to better understand the vibration environment on the space station to enable future research.

  11. Electron Cyclotron Resonance Heating (ECRH) Control System

    International Nuclear Information System (INIS)

    Heefner, J.W.; Williams, C.W.; Lauze, R.R.; Karsner, P.G.

    1985-01-01

    The ECRH Control System was installed on the Tandem Mirror Experiment-Upgrade (TMX-U) in 1980. The system provides approximately 1 MW of 28 GHz microwave power to the TMX-U plasma. The subsystems of ECRH that must be controlled include high-voltage charging supplies, series pass tubes, and magnet supplies. In addition to the devices that must be controlled, many interlocks must be continuously monitored. The previous control system used relay logic and analog controls to operate the system. This approach has many drawbacks such as lack of system flexibility and maintainability. In order to address these problems, it was decided to go with a CAMAC and Modicon based system that uses a Hewlett-Packard 9836C personal computer to replace the previous analog controls. 2 figs

  12. Resonances

    DEFF Research Database (Denmark)

    an impetus or drive to that account: change, innovation, rupture, or discontinuity. Resonances: Historical Essays on Continuity and Change explores the historiographical question of the modes of interrelation between these motifs in historical narratives. The essays in the collection attempt to realize...... theoretical consciousness through historical narrative ‘in practice’, by discussing selected historical topics from Western cultural history, within the disciplines of history, literature, visual arts, musicology, archaeology, philosophy, and theology. The title Resonances indicates the overall perspective...... of the book: how connotations of past meanings may resonate through time, in new contexts, assuming new meanings without surrendering the old....

  13. Effect of ionising radiation on potassium pentacyanonitrosyl ruthenate(II): an electron spin resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Vugman, Ney V.; Pinhal, Nelson M.; Amorim, Helio S. de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Fisica. Dept. de Fisica dos Solidos. E-mail: ney@if.ufrj.br; Santos, Cristina M.P. dos; Faria, Roberto B. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Quimica. Dept. de Quimica Inorganica

    2000-06-01

    Amorphous potassium pentacyanonitrosyl ruthenate (II) was synthesized and characterized by UV, IR, X-ray diffraction and thermogravimetric analysis. Electron Spin Resonance spectroscopy reveals the presence of paramagnetic ruthenate (i) complexes and NO{sub 2} radicals in the X-irradiated diamagnetic salt. Spin-Hamiltonian parameters of the [Ru (CN){sub 5} N O]{sup 3-} complex (g=2.0064, A ({sup 14} N) = 60.7 MHz, g = 1.999, A ({sup 14} N) = 77.3 MHz) support an electron capture in a {pi}{sup *} molecular orbital of the nitrosyl group mixed with d{sub xz} and d{sub yz} ruthenium orbitals as recently predicted by theoretical calculations. Silver ions, present as impurities, are reduced to Ag(o) by X-irradiation and coordinate to four magnetically equivalent nitrogens in a distorted site, giving to a well resolved anisotropic ESR powder spectrum. (author)

  14. Embedded computer systems for control applications in EBR-II

    International Nuclear Information System (INIS)

    Carlson, R.B.; Start, S.E.

    1993-01-01

    The purpose of this paper is to describe the embedded computer systems approach taken at Experimental Breeder Reactor II (EBR-II) for non-safety related systems. The hardware and software structures for typical embedded systems are presented The embedded systems development process is described. Three examples are given which illustrate typical embedded computer applications in EBR-II

  15. Clinical software VIII for magnetic resonance imaging systems

    International Nuclear Information System (INIS)

    Kohno, Satoru; Takeo, Kazuhiro

    2001-01-01

    This report describes the latest techniques of MRA (magnetic resonance angiography) and the brain attack diagnosis protocol which are now effectively utilized in the Shimadzu-Marconi MAGNEX ECLIPSE MRI (magnetic resonance imaging) system (1.5 tesla type) and the MAGNEX POLARIS MRI system (1.0 tesla type). As for the latest techniques for MRA, this report refers to the SLINKY (sliding interleaved ky) technique, which provides high-resolution images over a wide range in the direction of slice, without using contrast agent, and to the iPass technique which enables highly reliable CE-MRA (contrast-enhanced magnetic resonance angiography), through easy and simple operation. Also reported are the techniques of diffusion imaging and perfusion imaging, utilized for stroke assessment. (author)

  16. Clinical software VIII for magnetic resonance imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Kohno, Satoru; Takeo, Kazuhiro [Medical Applications Department, Medical Systems Division, Shimadzu Corporation, Kyoto (Japan)

    2001-02-01

    This report describes the latest techniques of MRA (magnetic resonance angiography) and the brain attack diagnosis protocol which are now effectively utilized in the Shimadzu-Marconi MAGNEX ECLIPSE MRI (magnetic resonance imaging) system (1.5 tesla type) and the MAGNEX POLARIS MRI system (1.0 tesla type). As for the latest techniques for MRA, this report refers to the SLINKY (sliding interleaved ky) technique, which provides high-resolution images over a wide range in the direction of slice, without using contrast agent, and to the iPass technique which enables highly reliable CE-MRA (contrast-enhanced magnetic resonance angiography), through easy and simple operation. Also reported are the techniques of diffusion imaging and perfusion imaging, utilized for stroke assessment. (author)

  17. The SNS Resonance Control Cooling System Control Valve Upgrade Performance

    International Nuclear Information System (INIS)

    Williams, Derrick C.; Schubert, James Phillip; Tang, Johnny Y.

    2008-01-01

    The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

  18. Ion cyclotron resonance heating system on Aditya

    Indian Academy of Sciences (India)

    Duration of 500 ms is sufficient for operation on Aditya, however, the same system feeds the final stage of the 1·5 MW ICRH system being prepared for the steady-state superconducting tokamak (SST-1) for a duration of 1000 s. Radio frequency (RF) power (225 kW) has been generated and successfully tested on a dummy ...

  19. Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies

    DEFF Research Database (Denmark)

    Ghasemi, Negareh; Zare, Firuz; Davari, Pooya

    2017-01-01

    Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectri...... receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer....

  20. Forced nonlinear resonance in a system of coupled oscillators.

    Science.gov (United States)

    Glebov, Sergei; Kiselev, Oleg; Tarkhanov, Nikolai

    2011-06-01

    We consider a resonantly perturbed system of coupled nonlinear oscillators with small dissipation and outer periodic perturbation. We show that for the large time t∼ɛ(-2) one component of the system is described for the most part by the inhomogeneous Mathieu equation while the other component represents pulsation of large amplitude. A Hamiltonian system is obtained which describes for the most part the behavior of the envelope in a special case. The analytic results agree with numerical simulations.

  1. Integrated Microfluidic Sensor System with Magnetostrictive Resonators

    KAUST Repository

    Liang, Cai

    2011-12-08

    The present embodiments describe a method that integrates a magnetostrictive sensor with driving and detecting elements into a microfluidic chip to detect a chemical, biochemical or biomedical species. These embodiments may also measure the properties of a fluid such as viscosity, pH values. The whole system can be referred to lab-on-a-chip (LOC) or micro-total-analysis-systems (.mu.TAS). In particular, this present embodiments include three units, including a microfluidics unit, a magnetostrictive sensor, and driving/detecting elements. An analyzer may also be provided to analyze an electrical signal associated with a feature of a target specimen.

  2. Enriched vibrational resonance in certain discrete systems

    Indian Academy of Sciences (India)

    A JEEVAREKHA, M SANTHIAH and P PHILOMINATHAN. ∗. P.G. and Research Department of Physics, A.V.V.M. Sri Pushpam College (Autonomous), Poondi, ..... the action of low-frequency signal alone, whereas figure 9c depicts the bifurcation pattern of the system described by eq. (3). It is clearly depicted that with the ...

  3. Nuclear process heat system AVR-II

    International Nuclear Information System (INIS)

    Fassbender, J.; Altes, J.; Becker, S.; Bongartz, R.; Breitbach, G.; David, P.H.; Ehrhardt, K.D.; Hennings, W.; Jahn, W.; Katscher, W.; Koschmieder, D.; Kroeger, W.; Krohn, H.; Meessen, H.; Meister, G; Mertens, J.; Mohr, H.G.; Moormann, R.; Rehm, W.; Wolters, J.

    1983-03-01

    Concerning safety features, the AVR-II differs appreciably from the comprehensive systems with thermal output of several hundred megawatts that have been examined so far. The essential differences are: slender steel pressure vessel instead of a prestressed-concrete vessel; no seperate afterheat removal system; afterheat removal is possible through steel pressure vessel surface; control and shutdown over reflector rods only; little redundance of operational systems; simplified containment; areal cooler to cool the reactor cavern. Safety is basically founded on passive system characteristics; the requirements on active safety devices may therefore be reduced. The different plant design requires appropriate changes in the spectrum of incidents; in particular, there is a shift in the importance of certain typer of incidents. (orig./GL) [de

  4. Microwave photonics systems based on whispering-gallery-mode resonators.

    Science.gov (United States)

    Coillet, Aurélien; Henriet, Rémi; Phan Huy, Kien; Jacquot, Maxime; Furfaro, Luca; Balakireva, Irina; Larger, Laurent; Chembo, Yanne K

    2013-08-05

    Microwave photonics systems rely fundamentally on the interaction between microwave and optical signals. These systems are extremely promising for various areas of technology and applied science, such as aerospace and communication engineering, sensing, metrology, nonlinear photonics, and quantum optics. In this article, we present the principal techniques used in our lab to build microwave photonics systems based on ultra-high Q whispering gallery mode resonators. First detailed in this article is the protocol for resonator polishing, which is based on a grind-and-polish technique close to the ones used to polish optical components such as lenses or telescope mirrors. Then, a white light interferometric profilometer measures surface roughness, which is a key parameter to characterize the quality of the polishing. In order to launch light in the resonator, a tapered silica fiber with diameter in the micrometer range is used. To reach such small diameters, we adopt the "flame-brushing" technique, using simultaneously computer-controlled motors to pull the fiber apart, and a blowtorch to heat the fiber area to be tapered. The resonator and the tapered fiber are later approached to one another to visualize the resonance signal of the whispering gallery modes using a wavelength-scanning laser. By increasing the optical power in the resonator, nonlinear phenomena are triggered until the formation of a Kerr optical frequency comb is observed with a spectrum made of equidistant spectral lines. These Kerr comb spectra have exceptional characteristics that are suitable for several applications in science and technology. We consider the application related to ultra-stable microwave frequency synthesis and demonstrate the generation of a Kerr comb with GHz intermodal frequency.

  5. Photonic crystal resonator integrated in a microfluidic system

    DEFF Research Database (Denmark)

    Rodrigues de Sousa Nunes, Pedro André; Mortensen, Niels Asger; Kutter, Jörg Peter

    2008-01-01

    We report on a novel optofluidic system consisting of a silica-based 1D photonic crystal, integrated planar waveguides, and electrically insulated fluidic channels. An array of pillars in a microfluidic channel designed for electrochromatography is used as a resonator for on-column label...

  6. Nuclear magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Knaap, M.S. van der; Valk, J.

    1989-01-01

    In this article a review is given of the use of magnetic resonance imaging for the central nervous system. An example of the screening of the population for multiple scelerosis is given. A good preliminary examination and the supply of relevant information to the person which performs the imaging is necessary. (R.B.). 9 figs.; 4 tabs

  7. Neural Network Model Of The PXIE RFQ Cooling System and Resonant Frequency Response

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, Auralee [Fermilab; Biedron, Sandra [Colorado State U., Fort Collins; Bowring, Daniel [Fermilab; Chase, Brian [Fermilab; Edelen, Jonathan [Fermilab; Milton, Stephen [Colorado State U., Fort Collins; Steimel, Jim [Fermilab

    2016-06-01

    As part of the PIP-II Injector Experiment (PXIE) accel-erator, a four-vane radio frequency quadrupole (RFQ) accelerates a 30-keV, 1-mA to 10-mA H' ion beam to 2.1 MeV. It is designed to operate at a frequency of 162.5 MHz with arbitrary duty factor, including continuous wave (CW) mode. The resonant frequency is controlled solely by a water-cooling system. We present an initial neural network model of the RFQ frequency response to changes in the cooling system and RF power conditions during pulsed operation. A neural network model will be used in a model predictive control scheme to regulate the resonant frequency of the RFQ.

  8. Effects of the radial electric field resonances on the particle orbits and loss cones in TJ-II

    International Nuclear Information System (INIS)

    Guasp, J.; Liniers, M.

    1997-07-01

    The effects of the radial electric field resonances on the trapping and confinement of low and intermediate energy ions (0.1-1 keV) for the Reference configuration of TJ-II have been analysed. In TJ-II these resonances appear for electric potentials that grow with pitch and with the square root of the initial kinetic energy and are placed inside strips whose width increases with the initial radius and with the absolute value of initial pitch. The 0-Resonance is the most important one for particle trapping, it appears for high electric potential (between 1000 and 3000 V for 0.5 keV ions) with the same sign than pitch, inside very wide strips (several thousands of V). Along these band periphery, for potential intensities below the central resonant values, there exists a very strong increase of particle trapping. Instead, around the resonance center, the trapping is inhibited and a very strong increase of the passing particle population appears. This increase is higher for the torus external side (Theta approximately 0 degree centigree) and for small initial radius. For peripherical particles wide loss strips appear along the border of the resonant band corresponding to more positive potential. The 2-Resonance has small effect on trapping but affects strongly to the of peripherical passing particles. It appears for moderate electric potential (between 400 and 1000 V for 0.5 keV ions) with sign opposite than pitch and inside narrow bands than the 0-Resonance. In this case a loss of peripherical passing particles appears, placed also along the more positive potential band side. The other Resonances (except the -4) have much less effect on particle trapping and confinement. All these phenomena have been explained by the action of magnetic barriers and different mechanisms for particle orbit modification. (Author) 8 refs

  9. Harmonic-Resonance Analysis in a Maglev Feeding System

    Science.gov (United States)

    Shigeeda, Hidenori; Okui, Akinobu; Akagi, Hirofumi

    A feeding circuit for a superconducting magnetic levitation train system, or the so-called “maglev” consists of feeder cables and armature coils which show characteristics of a distributed-parameter line. Electric power is supplied to the cables and coils by PWM inverters whose output voltage contains a large amount of harmonics. As a result, a harmonic resonance may occur in the feeding circuit. Besides the above characteristics, the connecting point of sections (groups of armature coils) or the feeder cables length changes according to the movement of a maglev train, thus causing changes in the harmonic-resonance characteristics of the feeding circuit. This paper describes analytical results of the harmonic resonance in the feeding circuit for the maglev, with the focus on changes in the connecting point of sections and the feeder cables length.

  10. Resonant scattering induced thermopower in one-dimensional disordered systems

    Science.gov (United States)

    Müller, Daniel; Smit, Wilbert J.; Sigrist, Manfred

    2015-05-01

    This study analyzes thermoelectric properties of a one-dimensional random conductor which shows localization effects and simultaneously includes resonant scatterers yielding sharp conductance resonances. These sharp features give rise to a distinct behavior of the Seebeck coefficient in finite systems and incorporate the degree of localization as a means to enhance thermoelectric performance, in principle. The model for noninteracting electrons is discussed within the Landauer-Büttiker formalism such that analytical treatment is possible for a wide range of properties, if a special averaging scheme is applied. The approximations in the averaging procedure are tested with numerical evaluations showing good qualitative agreement, with some limited quantitative disagreement. The validity of low-temperature Mott's formula is determined and a good approximation is developed for the intermediate temperature range. In both regimes the intricate interplay between Anderson localization due to disorder and conductance resonances of the disorder potential is analyzed.

  11. Nuclear magnetic resonance studies of biological systems

    International Nuclear Information System (INIS)

    Antypas, W.G. Jr.

    1988-01-01

    The difference between intracellular and extracellular proton relaxation rates provides the basis for the determination of the mean hemoglobin concentration (MHC) in red blood cells. The observed water T 1 relaxation data from red blood cell samples under various conditions were fit to the complete equation for the time-dependent decay of magnetization for a two-compartment system including chemical exchange. The MHC for each sample was calculated from the hematocrit and the intracellular water fraction as determined by NMR. The binding of the phosphorylcholine (PC) analogue, 2-(trimethylphosphonio)-ethylphosphate (phosphoryl-phosphocholine, PPC) to the PC binding myeloma proteins TEPC-15, McPC 603, and MOPC 167 was studied by 31 P NMR

  12. RESONANCE

    Indian Academy of Sciences (India)

    maceutical, paper, food, dyes, petrochemi- cals, pigments, etc., to identify molecules, to monitor reaction products and so on. One of the most spectacular contributions of NMR has been in the development of magnetic resonance imaging (MRI), a method that has today revolutionized diagnosis and treatment of diseases in ...

  13. Beam Position Monitor System for PEP II

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Stephen R.; Aiello, G.Roberto; Hendrickson, Linda J.; Johnson, Ronald G.; Mills, Mark R.; Olsen, Jeff J.; /SLAC

    2011-09-12

    We describe the beam position monitor system built for PEP-II, the B-factory at SLAC. The system reports beam position for bunches of between 5 x 10{sup 8} and 8 x 10{sup 10} electron charges, either singly or as continuous streams of bunches every 4.2 ns. Resolution at full charge is to be better than 10 microns in a single turn. Higher resolution is available via on-board multi-turn averaging. The position signal is processed in a 20 MHz bandwidth around 952 MHz. This bandwidth, rather broader than that typical of RF position monitors, allows good resolution for low charge single bunches. Additional novel features include stringent control of return losses in order to minimize cross-talk between nearby bunches which may contain very different charges. The digitizing electronics is multiplexed between the two PEP-II storage rings. Design, construction, and installation experience, as well as first results with beam are presented.

  14. Study of the influence of PPO in the compatibility of the system PA6/PC/PPO through nuclear magnetic resonance II - Composition changes in the PA6/PC/PPO system; Estudo da afluencia do PPo na compatibilidade do sistema PA6/PC/PPO atraves de espectrometria de resonancia magnetica nuclear. II - Mudanca na composicao do sistema PA6/PC/PPO

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Dilma Alves; Oliveira, Clara Marize F.; Tavares, Maria Ines Bruno [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Macromoleculas; Menezes, Sonia M.C. [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisa

    1997-12-31

    This work aims to study the influence in the quantities of poly(propylene oxide) in the miscibility of the system 6-poly-amide/ poly - carbonate / poly (propylene oxide). NMR was used as chemical instrumental technique for the analysis. Results are presented 15 refs.

  15. IMPLEMENTATION OF A TUNING SYSTEM FOR HELMHOLTZ RESONATOR ARRAYS IN A HVAC DUCT

    OpenAIRE

    寺尾, 道仁; Terao, Michihito; 関根, 秀久; Sekine, Hidehisa; 鈴木, 誠人; Suzuki, Masato

    2010-01-01

    Onsite tuning is mandatory to utilize Helmholtz resonators for HVAC ducts. However, no tuning device or general-use system is yet available, and engineers have thus been avoiding the use of such resonators. The objective of this study is to develop a tuning system for resonator arrays for HVAC ducts. We employed the cavity volume, resonator neck resistanceand neck open area as control parameters to tune the resonance frequency, resonancesharpness and sound dissipation factor, respectively. To...

  16. Authentication Sensing System Using Resonance Evaluation Spectroscopy (ASSURES)

    Science.gov (United States)

    Trolinger, James D.; Dioumaev, Andrei K.; Lal, Amit K.; Dimas, Dave

    2017-08-01

    This paper describes an ongoing instrument development project to distinguish genuine manufactured components from counterfeit components; we call the instrument ASSURES (Authentication Sensing System Using Resonance Evaluation Spectroscopy). The system combines Laser Doppler Vibrometry with acoustical resonance spectroscopy, augmented with finite element analysis. Vibrational properties of components, such as resonant modes, damping, and spectral frequency response to various forcing functions depend strongly upon the mechanical properties of the material, including its size, shape, internal hardness, tensile strength, alloy/composite compositions, flaws, defects, and other internal material properties. Although acoustic resonant spectroscopy has seen limited application, the information rich signals in the vibrational spectra of objects provide a pathway to many new applications. Components with the same shape but made of different materials, different fatigue histories, damage, tampering, or heat treatment, will respond differently to high frequency stimulation. Laser Doppler Vibrometry offers high sensitivity and frequency bandwidth to measure the component's frequency spectrum, and overcomes many issues that limit conventional acoustical resonance spectroscopy, since the sensor laser beam can be aimed anywhere along the part as well as to multiple locations on a part in a non-contact way. ASSURES is especially promising for use in additive manufacturing technology by providing signatures as digital codes that are unique to specific objects and even to specific locations on objects. We believe that such signatures can be employed to address many important issues in the manufacturing industry. These include insuring the part meets the often very rigid specifications of the customer and being able to detect non-visible internal manufacturing defects or non-visible damage that has occurred after manufacturing.

  17. Interpretation of the Electron Paramagnetic Resonance Spectra of Copper(II)-Tyrosine Complex

    Science.gov (United States)

    Xu, Xiao-Hui; Kuang, Min-Quan

    2017-12-01

    The electron paramagnetic resonance (EPR) spectra of [Cu(l-tyrosine)2]n (CuA) were interpreted based on the fourth-order perturbation treatments where the contributions due to the local distortion, ligand orbit and spin-orbit coupling were included. The calculated band transitions d_{x^2} - y^2 to dxy (≈16412 cm-1) and d_{z^2} (≈14845 cm-1) agree well with the band analysis results (d_{x^2} - y^2 \\to d_{xy} ≈16410 and d_{x^2} - y^2 \\to d_{z^2} ≈14850 cm-1). The unresolved separations d_{x^2} - y^2 \\to d_{xz} and d_{x^2} - y^2 \\to d_{yz} in the absorption spectra were evaluated as 26283 and 26262 cm-1, respectively. For CuA, copper chromophores in 1,3-diaminorpropane isophtalate copper(II) complex (CuB) and N-methyl-1,2-diaminoetaane-bis copper(II) polymer (CuC), the transition d_{x^2} - y^2 \\to d_{xy} (=E1≈10Dq) suffered an increase with a decrease in R̅L which was evaluated as the mean value of the copper-ligand bond lengths. The correlations between the tetragonal elongation ratio ρ (=(Rz-R̅L)/R̅L) (or the ratio G=(gz-ge)/((gx+gy)/2-ge)) and the g isotropy gav (=(gx+gy+gz)/3) (or the covalency factor N) for CuA, CuB and CuC were acquired and all the results were discussed.

  18. A novel power amplification scheme for nuclear magnetic resonance/nuclear quadrupole resonance systems

    Science.gov (United States)

    Zhang, Xinwang; Schemm, Nathan; Balkır, Sina

    2011-03-01

    Nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR)-based chemical analysis systems have been widely utilized in various areas such as medicine, security, and academic research. In these applications, the power amplifier stage plays a key role in generating the required oscillating magnetic fields within a radio frequency coil that serves as the probe. However, the bulky size and relatively low efficiency of the traditional power amplification schemes employed present a bottleneck for the realization of compact sized and portable NMR and NQR systems. To address this problem, this work presents a class D voltage-switching power amplification scheme with novel fast-start and fast-stop functions that are suitable for generating ideal NMR and NQR excitation signals. Compared to the traditional analog power amplifiers (PAs), the proposed switched-mode PA can achieve significant improvement on the power efficiency as well as the physical volume. A PA circuit for portable NQR-based explosive detection systems has been designed and built using the proposed scheme with 1 kW possible maximum output power and 10 MHz maximum operating frequency. Test results show that the presented PA achieves more than 60% measured efficiency within a highly compact volume while sustaining fast start and stop of excitation signals in the order of microseconds.

  19. A Siren Detection System based on Mechanical Resonant Filters

    Directory of Open Access Journals (Sweden)

    John N. Avaritsiotis

    2001-09-01

    Full Text Available A system based on mechanical resonant filters is proposed that can be used for the detection of acoustical signals the frequency components of which vary according to specific periodic patterns. Usually, signals of this category produced by the siren of an emergency vehicle. The device essentially implements a mechanical narrow filter bank that covers the frequency range of a typical siren sound. Signal detection is obtained by measuring the time delay between successive activation of the filters of the bank. The whole analysis reveals how a set of simple, low-cost mechanical resonant filters can replace an electronic analog or digital system for the implementation of a filter bank. Moreover, a scaling down procedure is proposed so that a microsystem may be developed.

  20. Magnetic resonance imaging of central nervous system haemorrhage

    International Nuclear Information System (INIS)

    Silberstein, M.; Hennessy, O.

    1993-01-01

    The variable magnetic resonance imaging appearances of central nervous system haemorrhage, both intra- and extra-axial, are described. These will vary with the type of image contrast (T1 or T2 weighting), the nature of the imaging sequence (spin-echo or gradient-echo) and the time from onset of haemorrhage. Magnetic resonance imaging is a useful technique for imaging haemorrhage in the central nervous system as it yields temporal information about haematoma development, and it is the only non-invasive means of imaging intraspinal haemorrhage. However, in the imaging of haematomas within 24 h of onset and in subarachnoid haemorrhage computed tomography is the investigation of choice. 13 refs., 6 figs

  1. The CDF-II silicon tracking system

    Energy Technology Data Exchange (ETDEWEB)

    F. Palmonari et al.

    2002-01-18

    The CDFII silicon tracking system, SVX, for Run II of the Fermilab Tevatron has up to 8 cylindrical layers with average radii spanning from {approx} (1.5 to 28.7) cm, and lengths ranging from {approx} (90 to 200) cm for a total active-area of {approx} 6 m{sup 2} and {approx} 7.2 x 10{sup 5} readout channels. SVX will improve the CDFII acceptance and efficiency for both B and high-Pt physics dependent upon b-tagging. Along with the description of the SVX we report some alignment survey data from the SVX assembly phase and the actual status of the alignment as it results from the offline data analysis. The problems encountered are also reviewed.

  2. Chaos and Beyond in a Water Filled Ultrasonic Resonance System

    Science.gov (United States)

    Lazlo, Adler; Yost, W.; Cantrell, John H.

    2013-01-01

    Finite amplitude ultrasonic wave resonances in a one-dimensional liquid-filled cavity, formed by a narrow band transducer and a plane reflector, are reported. The resonances are observed to include not only the expected harmonic and subharmonic signals (1,2) but chaotic signals as well. The generation mechanism requires attaining a threshold value of the driving amplitude that the liquid-filled cavity system becomes sufficiently nonlinear in response. The nonlinear features of the system were recently investigated via the construction of an ultrasonic interferometer having optical precision. The transducers were compressional, undamped quartz and lithium niobate crystals having the frequency range 1-10 MHz, driven by a high power amplifier. Both an optical diffraction system to characterize the diffraction pattern of laser light normally incident to the cavity and a receiving transducer attached to an aligned reflector with lapped flat and parallel surfaces were used to assess the generated resonance response in the cavity. At least 5 regions of excitation are identified.

  3. Frequency-difference-dependent stochastic resonance in neural systems

    Science.gov (United States)

    Guo, Daqing; Perc, Matjaž; Zhang, Yangsong; Xu, Peng; Yao, Dezhong

    2017-08-01

    Biological neurons receive multiple noisy oscillatory signals, and their dynamical response to the superposition of these signals is of fundamental importance for information processing in the brain. Here we study the response of neural systems to the weak envelope modulation signal, which is superimposed by two periodic signals with different frequencies. We show that stochastic resonance occurs at the beat frequency in neural systems at the single-neuron as well as the population level. The performance of this frequency-difference-dependent stochastic resonance is influenced by both the beat frequency and the two forcing frequencies. Compared to a single neuron, a population of neurons is more efficient in detecting the information carried by the weak envelope modulation signal at the beat frequency. Furthermore, an appropriate fine-tuning of the excitation-inhibition balance can further optimize the response of a neural ensemble to the superimposed signal. Our results thus introduce and provide insights into the generation and modulation mechanism of the frequency-difference-dependent stochastic resonance in neural systems.

  4. Noninvasive evaluation of adult onset myopathy from carnitine palmitoyl transferase II deficiency using proton magnetic resonance spectroscopy.

    Science.gov (United States)

    Videen, J S; Haseler, L J; Karpinski, N C; Terkeltaub, R A

    1999-08-01

    The adult onset metabolic myopathy of carnitine palmitoyl transferase II (CPT II) deficiency is under-recognized, in part due to variable degrees of enzyme deficiency and symptomatology, as well as limitations in means for noninvasive evaluation. We describe a proton magnetic resonance spectroscopy (MRS) technique, using a standard clinical magnetic resonance imaging scanner, to diagnose and help monitor the response to therapy in adult CPT II deficiency. A 53-year-old woman presented with a long standing history of diffuse aching and fatigue provoked by high fat intake, fasting, or prolonged exertion. Muscle biopsy revealed myopathic features and a deficiency (33% of control) of CPT II activity with elevated palmitoyl carnitine. Proton MRS of the soleus muscle was performed using a 1.5 Tesla scanner before and during dietary therapy. Proton MRS revealed shortening of the transverse relaxation time (T2), consistent with increased acetylation of the carnitine pool. The symptoms resolved completely by treatment with frequent feedings of a high carbohydrate diet low in long chain fatty acids supplemented with medium chain triglycerides and L-carnitine. Recovery of normal muscle MRS and carnitine T2 relaxation was documented by the third month of therapy. Proton MRS is a novel, potentially useful, and readily available adjunct in the diagnosis and therapeutic monitoring of muscle CPT II deficiency.

  5. Diagnostic imaging of psoriatic arthritis. Part II: magnetic resonance imaging and ultrasonography

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2016-06-01

    Full Text Available Plain radiography reveals specific, yet late changes of advanced psoriatic arthritis. Early inflammatory changes are seen both on magnetic resonance imaging and ultrasound within peripheral joints (arthritis, synovitis, tendons sheaths (tenosynovitis, tendovaginitis and entheses (enthesitis, enthesopathy. In addition, magnetic resonance imaging enables the assessment of inflammatory features in the sacroiliac joints (sacroiliitis, and the spine (spondylitis. In this article, we review current opinions on the diagnostics of some selective, and distinctive features of psoriatic arthritis concerning magnetic resonance imaging and ultrasound and present some hypotheses on psoriatic arthritis etiopathogenesis, which have been studied with the use of magnetic resonance imaging. The following elements of the psoriatic arthritis are discussed: enthesitis, extracapsular inflammation, dactylitis, distal interphalangeal joint and nail disease, and the ability of magnetic resonance imaging to differentiate undifferentiated arthritis, the value of whole-body magnetic resonance imaging and dynamic contrast-enhanced magnetic resonance imaging.

  6. Analysis of systemic lupus erythematosus (SLE) involving the central nervous system by magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kimihiro; Hara, Masako; Nakajima, Shinji and others

    1989-04-01

    Involvement of the central nervous system (CNS) commonly occurs in systemic lupus erythematosus (SLE). But definitive diagnosis remains difficult even with computed tomography (CT). In this study, we used the recently developed technique, magnetic resonance imaging (MRI) for CNS lupus and compared it with CT scans. CT was performed with a General Electric 8800 CT/T scanner. MRI was performed using a Mitsubishi Electric MMI-150 S. Ten patients with CNS lupus were divided into 3 groups. Group I included 4 cases with neurological manifestations alone. All lesions seen on CT were also detected by MRI, with greater clarity and extent. Furthermore, MRI depicted several microinfarcts in white matter without symptoms. Group II included 5 cases with psychiatric features alone. MRI detected a thalamic microinfarct in only one case while CT showed no abnormality in all cases. Group III included 1 case with both neurological and psychiatric symptoms. MRI demonstrated a small infarct of midbrain corresponding with neurological symptoms, more clearly than CT. Therefore MRI demonstrates the degree of brain involvement in SLE more accurately than CT. (author).

  7. Analysis of systemic lupus erythematosus (SLE) involving the central nervous system by magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Suzuki, Kimihiro; Hara, Masako; Nakajima, Shinji

    1989-01-01

    Involvement of the central nervous system (CNS) commonly occurs in systemic lupus erythematosus (SLE). But definitive diagnosis remains difficult even with computed tomography (CT). In this study, we used the recently developed technique, magnetic resonance imaging (MRI) for CNS lupus and compared it with CT scans. CT was performed with a General Electric 8800 CT/T scanner. MRI was performed using a Mitsubishi Electric MMI-150 S. Ten patients with CNS lupus were divided into 3 groups. Group I included 4 cases with neurological manifestations alone. All lesions seen on CT were also detected by MRI, with greater clarity and extent. Furthermore, MRI depicted several microinfarcts in white matter without symptoms. Group II included 5 cases with psychiatric features alone. MRI detected a thalamic microinfarct in only one case while CT showed no abnormality in all cases. Group III included 1 case with both neurological and psychiatric symptoms. MRI demonstrated a small infarct of midbrain corresponding with neurological symptoms, more clearly than CT. Therefore MRI demonstrates the degree of brain involvement in SLE more accurately than CT. (author)

  8. Comparative Analysis of Resonant Converters for Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Vuchev Stoyan

    2017-01-01

    Full Text Available The following paperwork presents a comparative analysis of multiphase resonant converters for applications in energy storage systems. Models of the examined converters are developed in the software environments of MATLAB and LTspice. Results from the simulation examination of the converters during charging of supercapacitors and rechargeable batteries are presented. These results are compared to results obtained from experimental examination of the converters via a laboratory stand. For the purposes of the experimental examination, a control system is developed on the base of a virtual instrument in LabVIEW. The advantages and disadvantages of the different converters are discussed.

  9. The PEP-II abort kicker system

    International Nuclear Information System (INIS)

    Lamare, J de; Donaldson, A.; Kulikov, A. Lipari, J.

    1997-07-01

    The PEP-II project has two storage rings. The HER (High Energy Ring) has up to 1.48 A of electron beam at 9 GeV, and the LER (Low Energy Ring) has up to 2.14 A of positron beam at 3.1 GeV. To protect the HER and LER beam lines in the event of a ring component failure, each ring has an abort kicker system which directs the beam into a dump when a failure is detected. Due to the high current of the beams, the beam kick is tapered from 100% to 80% in 7.33 uS (the beam transit time around the time). This taper distributes the energy evenly across the window which separates the ring from the beam dump such that the window is not damaged. The abort kicker trigger is synchronized with the ion clearing gap of the beam allowing for the kicker field to rise from 0-80% in 370 nS. This report discusses the design of the system controls, interlocks, power supplies, and modulator

  10. The Belle II SVD data readout system

    Energy Technology Data Exchange (ETDEWEB)

    Thalmeier, R., E-mail: Richard.Thalmeier@oeaw.ac.at [Institute of High Energy Physics, Austrian Academy of Sciences, 1050 Vienna (Austria); Adamczyk, K. [H. Niewodniczanski Institute of Nuclear Physics, Krakow 31-342 (Poland); Aihara, H. [Department of Physics, University of Tokyo, Tokyo 113-0033 (Japan); Angelini, C. [Dipartimento di Fisica, Universita’ di Pisa, I-56127 Pisa (Italy); INFN Sezione di Pisa, I-56127 Pisa (Italy); Aziz, T.; Babu, V. [Tata Institute of Fundamental Research, Mumbai 400005 (India); Bacher, S. [H. Niewodniczanski Institute of Nuclear Physics, Krakow 31-342 (Poland); Bahinipati, S. [Indian Institute of Technology Bhubaneswar, Satya Nagar (India); Barberio, E.; Baroncelli, Ti.; Baroncelli, To. [School of Physics, University of Melbourne, Melbourne, Victoria 3010 (Australia); Basith, A.K. [Indian Institute of Technology Madras, Chennai 600036 (India); Batignani, G. [Dipartimento di Fisica, Universita’ di Pisa, I-56127 Pisa (Italy); INFN Sezione di Pisa, I-56127 Pisa (Italy); Bauer, A. [Institute of High Energy Physics, Austrian Academy of Sciences, 1050 Vienna (Austria); Behera, P.K. [Indian Institute of Technology Madras, Chennai 600036 (India); Bergauer, T. [Institute of High Energy Physics, Austrian Academy of Sciences, 1050 Vienna (Austria); Bettarini, S. [Dipartimento di Fisica, Universita’ di Pisa, I-56127 Pisa (Italy); INFN Sezione di Pisa, I-56127 Pisa (Italy); Bhuyan, B. [Indian Institute of Technolog y Guwahati, Assam 781039 (India); Bilka, T. [Faculty of Mathematics and Physics, Charles University, 12116 Prague (Czech Republic); Bosi, F. [INFN Sezione di Pisa, I-56127 Pisa (Italy); and others

    2017-02-11

    The Belle II Experiment at the High Energy Accelerator Research Organization (KEK) in Tsukuba, Japan, will explore the asymmetry between matter and antimatter and search for new physics beyond the standard model. 172 double-sided silicon strip detectors are arranged cylindrically in four layers around the collision point to be part of a system which measures the tracks of the collision products of electrons and positrons. A total of 1748 radiation-hard APV25 chips read out 128 silicon strips each and send the analog signals by time-division multiplexing out of the radiation zone to 48 Flash Analog Digital Converter Modules (FADC). Each of them applies processing to the data; for example, it uses a digital finite impulse response filter to compensate line signal distortions, and it extracts the peak timing and amplitude from a set of several data points for each hit, using a neural network. We present an overview of the SVD data readout system, along with front-end electronics, cabling, power supplies and data processing.

  11. Brain magnetic resonance imaging findings in patients with systemic sclerosis.

    Science.gov (United States)

    Mohamed, Reem H A; Nassef, Amr A

    2010-02-01

    Systemic sclerosis is a multisystem disease where functional and structural abnormalities of small blood vessels prevail. Recently, transient ischemic attacks, ischemic stroke, and hemorrhages have been reported as primary consequence of vascular central nervous system affection in systemic sclerosis. Magnetic resonance imaging (MRI) is considered to be the most sensitive diagnostic technique for detecting symptomatic and asymptomatic lesions in the brain in cases of multifocal diseases. Evaluate brain changes in patients with systemic sclerosis using MRI. Thirty female patients with systemic sclerosis aged 27-61 years, with disease duration of 1-9 years and with no history of other systemic disease or cerebrovascular accidents, were enrolled. An age-matched female control group of 30 clinically normal subjects, underwent brain MR examination. Central nervous system involvement in the form of white matter hyperintense foci of variable sizes were found in significantly abundant forms in systemic sclerosis patients on MR evaluation than in the age-related control group, signifying a form of central nervous system vasculopathy. Such foci showed no definite correlation with disease duration, yet they showed significant correlation to severity of peripheral vascular disease, headaches, fainting attacks and depression in the group under study. Asymptomatic as well as symptomatic central nervous system ischemic vasculopathy is not uncommon in systemic sclerosis patients and MRI is considered a sensitive noninvasive screening tool for early detection of CNS involvement in patients with systemic sclerosis.

  12. Efimov resonances in atomic three-body systems

    International Nuclear Information System (INIS)

    Mezei, J. Zs.; Papp, Z.

    2006-01-01

    In a recent work [Phys. Rev. Lett. 94, 143201 (2005)], we reported an accumulation of three-body resonant states attached to n=2 and higher two-body thresholds. A more careful investigation revealed that there are resonances of the same kind above the n=1 threshold as well. This suggests that the resonances attached to the thresholds are Efimov resonances

  13. The fluorescence and resonance Rayleigh scattering spectra study on the interactions of palladium (II)-Nootropic chelate with Congo red and their analytical applications

    Science.gov (United States)

    Chen, Fang; Peng, Jingdong; Liu, Shaopu; Peng, Huanjun; Pan, Ziyu; Bu, Lingli; Xiao, Huan; Zhang, Ruiwen

    2017-04-01

    A highly sensitive detection approach of resonance Rayleigh scattering spectra (RRS) is firstly applied to analyzing nootropic drugs including piracetam (PIR) and oxiracetam (OXI). In HCl-NaAc buffer solution (pH = 3.0), the OXI chelated with palladium (II) to form the chelate cation [Pd2·OXI]2 +, and then reacted with Congo red (CGR) by virtue of electrostatic attraction and hydrophobic force to form binary complex [Pd2·OXI]. CGR2, which could result in the great enhancement of RRS. The resonance Rayleigh scattering signal was recorded at λex = λem = 375 nm. This mixture complex not only has higher RRS, but also makes contribution to significant increase of fluorescence, and the same phenomena also were discovered in PIR. The enhanced RRS intensity is in proportion to the PIR and OXI concentration in the range of 0.03-3.0 μg mL- 1, and the detection limit (DL) of RRS method for PIR and OXI is 2.3 ng mL- 1 and 9.7 ng mL- 1. In addition, the DL of fluorescence method for PIR and OXI is 8.4 μg mL- 1 and 19.5 μg mL- 1. Obviously, the RRS is the highly sensitive method, and the recoveries of the two kinds of nootropic drugs were range from 100.4% to 101.8.0% with RSD (n = 5) from 1.1% to 3.1% by RRS method. This paper not only investigated the optimum conditions for detecting nootropics with using RRS method, but also focused on the reasons for enhancing RRS intensity and the reaction mechanism, which in order to firm and contract the resultant. Finally, The RRS method has been applied to detect nootropic drugs in human urine samples with satisfactory results. Fig. S2. The effect of ionic strength: Pd (II)-CGR system (curve a); Pd (II)-OXI-CGR system (curve b); Pd (II)-PIR- CGR system (curve c). Pd (II): 2.0 × 10- 4 mol L- 1; CGR: 1.0 × 10- 5 mol L- 1; OXI: 1.5 μg mL- 1; PIR: 2 μg mL- 1; NaCl: 1 mol L- 1. Fig. S3. The effect of time: Pd (II)-OXI-CGR system (curve a); Pd (II)-PIR-CGR system (curve b). Pd (II): 2.0 × 10- 4 mol L- 1; CGR: 1.0 × 10- 5 mol L- 1

  14. Magnetic resonance imaging of the brain in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Kodama, Kazuhiro; Sato, Toshio; Koseki, Keijiro

    1987-01-01

    Cranial magnetic resonance imaging (MRI) was performed in five patients with systemic lupus erythematosus manifested by neurologic symptoms. The results were compared with those of the concurrent X-ray computed tomography (CT). CT scans showed slight cerebral atrophy in four patients, including one with coexisting enlargement of the lateral ventricle. In three of them, MRI scans showed additional abnormal appearance, possibly reflecting cerebral infarction and reversible changes in water content of cerebral tissues. The findings of MRI and CT in a small series of patients was disappointing in the explanation of the occurrence of neurologic symptoms. (Namekawa, K.)

  15. High sensitive detection of copper II ions using D-penicillamine-coated gold nanorods based on localized surface plasmon resonance

    Science.gov (United States)

    Hong, Yoochan; Jo, Seongjae; Park, Joohyung; Park, Jinsung; Yang, Jaemoon

    2018-05-01

    In this paper, we describe the development of a nanoplasmonic biosensor based on the localized surface plasmon resonance (LSPR) effect that enables a sensitive and selective recognition of copper II ions. First, we fabricated the nanoplasmonics as LSPR substrates using gold nanorods (GNR) and the nano-adsorption method. The LSPR sensitivity of the nanoplasmonics was evaluated using various solvents with different refractive indexes. Subsequently, D-penicillamine (DPA)—a chelating agent of copper II ions—was conjugated to the surface of the GNR. The limit of detection (LOD) for the DPA-conjugated nanoplasmonics was 100 pM. Furthermore, selectivity tests were conducted using various divalent cations, and sensitivity tests were conducted on the nanoplasmonics under blood-like environments. Finally, the developed nanoplasmonic biosensor based on GNR shows great potential for the effective recognition of copper II ions, even in human blood conditions.

  16. The Dynamics of Tide and Resonances in Exoplanetary Systems

    Science.gov (United States)

    Chen, Y. Y.

    2015-05-01

    In recent years, the planet formation theory and planetary system dynamics have become an important area of astronomy. With more details of exoplanets being found, many characteristics quite different from the solar system have been found in the exoplanetary systems. A large number of planets are found to be very close to their host star, and their periods are only a few days, which brings strong tidal dissipation with the star. Many period ratios of adjacent planets in multi-planetary systems are close to the simple integer ratios, which indicates that the planets are likely in the mean motion resonances (MMRs). The range of the angles between the orbital plane of the planets and the equatorial plane of their hosts expands from ≤sssim 7(°) for the planets in the solar system to 0(°) ˜ 180(°) , and some retrograde hot Jupiters exist. These new phenomena are testing out the traditional planetary formation theory and planetary system dynamics, but also provide an unprecedented opportunity for their further improvement and development. Based on these latest observational data and statistical features, the thesis investigates some special configurations combining the resonances and tidal dissipation by the way of planetary system dynamics. The thesis first reviews the primary applications and the latest progress in the tide as well as various resonances of exoplanets. Then it gives some tidal model derivations, including the classic one and most popular one, in order to understand the assumptions of the equilibrium tide. Meanwhile, the average rates of change of orbital elements under tidal dissipation are exhibited. By both numerical simulation and theoretical analysis, the following three questions are investigated: the evolution of the eccentricity of planets in the non-synchronous spin-orbit resonances, the characteristics of nearly 2:1 MMR and Laplace resonance under tidal dissipation, and the promoting role of the gravity of outer gas disk for exciting the

  17. Magnetic Responsive Hydrogel Material Delivery System II

    Science.gov (United States)

    2010-08-29

    agents, tissue repair, immunoassay, cell separation, biomagnetic separation of biomolecules, etc. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17...hyperthermic treatment of tumors, magnetic resonance imaging (MRI) as contrasting agents, tissue repair, immunoassay, cell separation, biomagnetic ...potential step forward in the use of these core-shell MNPs in robust controlled drug delivery, tissue repair, immunoassay, cell separation, biomagnetic

  18. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging.

  19. Preparation of a Cobalt(II) Cage: An Undergraduate Laboratory Experiment That Produces a ParaSHIFT Agent for Magnetic Resonance Spectroscopy

    Science.gov (United States)

    Burns, Patrick J.; Tsitovich, Pavel B.; Morrow, Janet R.

    2016-01-01

    Laboratory experiments that demonstrate the effect of paramagnetic complexes on chemical shifts and relaxation times of protons are a useful way to introduce magnetic resonance spectroscopy (MRS) probes or magnetic resonance imaging (MRI) contrast agents. In this undergraduate inorganic chemistry experiment, a paramagnetic Co(II) cage complex is…

  20. Space-Ready Advanced Imaging System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II effort Toyon will increase the state-of-the-art for video/image systems. This will include digital image compression algorithms as well as system...

  1. Railroad Classification Yard Technology Manual: Volume II : Yard Computer Systems

    Science.gov (United States)

    1981-08-01

    This volume (Volume II) of the Railroad Classification Yard Technology Manual documents the railroad classification yard computer systems methodology. The subjects covered are: functional description of process control and inventory computer systems,...

  2. Comparison of APACHE II and SAPS II Scoring Systems in Prediction of Critically ill Patients’ Outcome

    Directory of Open Access Journals (Sweden)

    Hamed Aminiahidashti

    2017-01-01

    Full Text Available Introduction: Using physiologic scoring systems for identifying high-risk patients for mortality has been considered recently. This study was designed to evaluate the values of Acute Physiology and Chronic Health Evaluation II (APACHE II and Simplified Acute Physiologic Score (SAPS II models in prediction of 1-month mortality of critically ill patients.Methods: The present prospective cross sectional study was performed on critically ill patients presented to emergency department during 6 months. Data required for calculation of the scores were gathered and performance of the models in prediction of 1-month mortality were assessed using STATA software 11.0.Results: 82 critically ill patients with the mean age of 53.45 ± 20.37 years were included (65.9% male. Their mortality rate was 48%. Mean SAPS II (p < 0.0001 and APACHE II (p = 0.0007 scores were significantly higher in dead patients. Area under the ROC curve of SAPS II and APACHE II for prediction of mortality were 0.75 (95% CI: 0.64 - 0.86 and 0.72 (95% CI: 0.60 - 0.83, respectively (p = 0.24. The slope and intercept of SAPS II were 1.02 and 0.04, respectively. In addition, these values were 0.92 and 0.09 for APACHE II, respectively.Conclusion: The findings of the present study showed that APACHE II and SAPS II had similar value in predicting 1-month mortality of patients. Discriminatory powers of the mentioned models were acceptable but their calibration had some amount of lack of fit, which reveals that APACHE II and SAPS II are partially perfect.

  3. Study and design of the ion cyclotron resonance heating system for the stellarator Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Ongena, J.; Messiaen, A.; Van Eester, D.; Schweer, B.; Dumortier, P.; Durodie, F.; Kazakov, Ye. O.; Louche, F.; Vervier, M.; Koch, R.; Krivska, A.; Lyssoivan, A.; Van Schoor, M.; Wauters, T. [Laboratory for Plasmaphysics, Ecole Royale Militaire–Koninklijke Militaire School, TEC Partner, Brussels (Belgium); Borsuk, V.; Neubauer, O.; Schmitz, O. [IEK-4/Plasmaphysik, Forschungszentrum Juelich, TEC Partner, Juelich (Germany); Offermans, G. [ZEA-1, Forschungszentrum Juelich, Juelich (Germany); Altenburg, Y.; Baylard, C. [Max-Planck Institute für Plasmaphysik, Teilinstitut Greifswald, Greifswald (Germany); and others

    2014-06-15

    The current status of the mechanical and electromagnetic design for the ICRF antenna system for W7-X is presented. Two antenna plugins are discussed: one consisting of a pair of straps with pre-matching to cover the first frequency band, 25–38 MHz, and a second one consisting of two short strap triplets to cover a frequency band around 76 MHz. This paper focusses on the two strap antenna for the lower frequency band. Power coupling of the antenna to a reference plasma profile is studied with the help of the codes TOPICA and Microwave Studio that deliver the scattering matrix needed for the optimization of the geometric parameters of the straps and antenna box. Radiation power spectra for different phasings of the two straps are obtained using the code ANTITER II and different heating scenario are discussed. The potential for heating, fast particle generation, and current drive is discussed. The problem of RF coupling through the plasma edge and of edge power deposition is summarized. Important elements of the complete ion cyclotron resonance heating system are discussed: a resonator circuit with tap feed to limit the maximum voltage in the system, and a decoupler to counterbalance the large mutual coupling between the 2 straps. The mechanical design highlights the challenges encountered with this antenna: adaptation to a large variety of plasma configurations, the limited space within the port to accommodate the necessary matching components and the watercooling needed for long pulse operation.

  4. Disc position in clinically asymptomatic, pretreatment adolescents with Class I, II, or III malocclusion : A retrospective magnetic resonance imaging study.

    Science.gov (United States)

    Gökalp, Hatice

    2016-05-01

    To test the null hypothesis that children with Class I, II, and III malocclusions who have not undergone orthodontic therapy present with displaced discs. This study relied on retrospective material consisting of 76 unilateral left sagittal-oblique temporomandibular joint (TMJ) magnetic resonance imaging (MRIs) and lateral cephalometric radiographs taken in maximum intercuspal position in patients with clinically symptom-free and orthodontically untreated Class I (n = 30; 19 girls and 11 boys), Class II (n = 26; 10 girls and 16 boys), and Class III malocclusion (n = 20; 5 girls and 15 boys). The mean ages of patients with Class I, II, and III malocclusions were 10.55 ± 0.81, 11.71 ± 0.31, and 8.98 ± 1.80 years, respectively. Study groups were compared with one-way ANOVA analysis or Welch ANOVA test. Differences were evaluated via the Tukey HSD or Games-Howell test. Disc-condyle positions were almost within normal limits in Class I malocclusion. The disc was positioned anteriorly relative to the condyle (p Class II malocclusion (p Class III malocclusion. Disc-condyle positions were observed to be almost identical in all three malocclusion classes. Disc-condyle position was nearly normal in patients with Class I malocclusion. Nevertheless, a Class II malocclusion is more apt to reveal anterior disc displacement than a Class III malocclusion.

  5. Present status of the TJ-II remote participation system

    Energy Technology Data Exchange (ETDEWEB)

    Vega, J. [Asociacion EURATOM/CIEMAT para Fusion., Avda. Complutense 22, 28040 Madrid (Spain)]. E-mail: jesus.vega@ciemat.es; Sanchez, E. [Asociacion EURATOM/CIEMAT para Fusion., Avda. Complutense 22, 28040 Madrid (Spain); Lopez, A. [Asociacion EURATOM/CIEMAT para Fusion., Avda. Complutense 22, 28040 Madrid (Spain); Portas, A. [Asociacion EURATOM/CIEMAT para Fusion., Avda. Complutense 22, 28040 Madrid (Spain); Ochando, M. [Asociacion EURATOM/CIEMAT para Fusion., Avda. Complutense 22, 28040 Madrid (Spain); Ascasibar, E. [Asociacion EURATOM/CIEMAT para Fusion., Avda. Complutense 22, 28040 Madrid (Spain); Mollinedo, A. [CIEMAT. Computing Center, Avda. Complutense 22, 28040 Madrid (Spain); Munoz, J. [CIEMAT. Computing Center, Avda. Complutense 22, 28040 Madrid (Spain); Sanchez, A. [CIEMAT. Computing Center, Avda. Complutense 22, 28040 Madrid (Spain); Ruiz, M. [Universidad Politecnica de Madrid. Dpto. Sistemas Electronicos y de Control, Campus Sur. Ctra. Valencia, km 7, 28031 Madrid (Spain); Barrera, E. [Universidad Politecnica de Madrid. Dpto. Sistemas Electronicos y de Control, Campus Sur. Ctra. Valencia, km 7, 28031 Madrid (Spain); Lopez, S. [Universidad Politecnica de Madrid. Dpto. Sistemas Electronicos y de Control, Campus Sur. Ctra. Valencia, km 7, 28031 Madrid (Spain); Castro, R. [Red.es-RedIRIS, Edificio Bronce, Plaza Manuel Gomez Moreno, s/n, 28020 Madrid (Spain); Lopez, D. [Red.es-RedIRIS, Edificio Bronce, Plaza Manuel Gomez Moreno, s/n, 28020 Madrid (Spain)

    2005-11-15

    The TJ-II remote participation system (RPS) was designed to extend to Internet the working capabilities provided in the TJ-II local environment, i.e., tracking the TJ-II operation, monitoring/programming data acquisition and control systems, and accessing databases. The TJ-II RPS was based on web and Java technologies because of their open character, security properties and technological maturity. A web server acts as a communication front-end between remote participants and local TJ-II elements. From the server side, web services are provided by means of resources supplied by JSP pages. The client part makes use of web browsers and ad hoc Java applications. The operation requires the use of a distributed authentication and authorization system. This development employs the PAPI System. At present, approximately 1000 digitisation channels can be managed from the TJ-II RPS. Furthermore, processing software based on a 4GL language (LabView) can be downloaded to multiprocessor data acquisition systems. Also, 15 diagnostic control systems, databases and the operation logbook are available from the RPS. The system even allows for the physicist in charge of operation to be in a remote location. Four Spanish universities make use of the TJ-II remote participation system capabilities for joint collaborations: these are the Universidad Politecnica de Madrid (UPM), Universidad Nacional de Educacion a Distancia (UNED), Universidad Complutense de Madrid (UCM) and Universidad Politecnica de Cataluna (UPC)

  6. Present status of the TJ-II remote participation system

    International Nuclear Information System (INIS)

    Vega, J.; Sanchez, E.; Lopez, A.; Portas, A.; Ochando, M.; Ascasibar, E.; Mollinedo, A.; Munoz, J.; Sanchez, A.; Ruiz, M.; Barrera, E.; Lopez, S.; Castro, R.; Lopez, D.

    2005-01-01

    The TJ-II remote participation system (RPS) was designed to extend to Internet the working capabilities provided in the TJ-II local environment, i.e., tracking the TJ-II operation, monitoring/programming data acquisition and control systems, and accessing databases. The TJ-II RPS was based on web and Java technologies because of their open character, security properties and technological maturity. A web server acts as a communication front-end between remote participants and local TJ-II elements. From the server side, web services are provided by means of resources supplied by JSP pages. The client part makes use of web browsers and ad hoc Java applications. The operation requires the use of a distributed authentication and authorization system. This development employs the PAPI System. At present, approximately 1000 digitisation channels can be managed from the TJ-II RPS. Furthermore, processing software based on a 4GL language (LabView) can be downloaded to multiprocessor data acquisition systems. Also, 15 diagnostic control systems, databases and the operation logbook are available from the RPS. The system even allows for the physicist in charge of operation to be in a remote location. Four Spanish universities make use of the TJ-II remote participation system capabilities for joint collaborations: these are the Universidad Politecnica de Madrid (UPM), Universidad Nacional de Educacion a Distancia (UNED), Universidad Complutense de Madrid (UCM) and Universidad Politecnica de Cataluna (UPC)

  7. HPC Colony II: FAST_OS II: Operating Systems and Runtime Systems at Extreme Scale

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Jose [IBM, Armonk, NY (United States)

    2013-11-13

    HPC Colony II has been a 36-month project focused on providing portable performance for leadership class machines—a task made difficult by the emerging variety of more complex computer architectures. The project attempts to move the burden of portable performance to adaptive system software, thereby allowing domain scientists to concentrate on their field rather than the fine details of a new leadership class machine. To accomplish our goals, we focused on adding intelligence into the system software stack. Our revised components include: new techniques to address OS jitter; new techniques to dynamically address load imbalances; new techniques to map resources according to architectural subtleties and application dynamic behavior; new techniques to dramatically improve the performance of checkpoint-restart; and new techniques to address membership service issues at scale.

  8. Simulation of the S2 state multiline electron paramagnetic resonance signal of photosystem II: a multifrequency approach.

    OpenAIRE

    Ahrling, K A; Pace, R J

    1995-01-01

    The S2 state electron paramagnetic resonance (EPR) multiline signal of Photosystem II has been simulated at Q-band (35 Ghz), X-band (9 GHz) and S-band (4 GHz) frequencies. The model used for the simulation assumes that the signal arises from an essentially magnetically isolated MnIII-MnIV dimer, with a ground state electronic spin ST = 1/2. The spectra are generated from exact numerical solution of a general spin Hamiltonian containing anisotropic hyperfine and quadrupolar interactions at bot...

  9. Adult onset glycogen storage disease type II (adult onset Pompe disease): report and magnetic resonance images of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Del Gaizo, Andrew [Emory University School of Medicine, Radiology Resident, Atlanta, GA (United States); Banerjee, Sima [Emory University School of Medicine, Musculoskeletal Radiology Department, Atlanta, GA (United States); Terk, Michael [Emory University School of Medicine, Radiology, Division of Musculoskeletal Imaging, Atlanta, GA (United States)

    2009-12-15

    Glycogen storage disease type II (GSDII), also referred to as Pompe disease or acid maltase deficiency, is a rare inherited condition caused by a deficiency in acid alpha-glucosidase (GAA) enzyme activity. The condition is often classified by age of presentation, with infantile and late onset variants (Laforet et al. J Neurology 55:1122-8, 2000). Late onset tends to present with progressive proximal muscle weakness and respiratory insufficiency (Winkel et al. J Neurology 252:875-84, 2005). We report two cases of biopsy confirmed adult onset GSDII, along with key Magnetic Resonance (MR) images. (orig.)

  10. Adult onset glycogen storage disease type II (adult onset Pompe disease): report and magnetic resonance images of two cases

    International Nuclear Information System (INIS)

    Del Gaizo, Andrew; Banerjee, Sima; Terk, Michael

    2009-01-01

    Glycogen storage disease type II (GSDII), also referred to as Pompe disease or acid maltase deficiency, is a rare inherited condition caused by a deficiency in acid alpha-glucosidase (GAA) enzyme activity. The condition is often classified by age of presentation, with infantile and late onset variants (Laforet et al. J Neurology 55:1122-8, 2000). Late onset tends to present with progressive proximal muscle weakness and respiratory insufficiency (Winkel et al. J Neurology 252:875-84, 2005). We report two cases of biopsy confirmed adult onset GSDII, along with key Magnetic Resonance (MR) images. (orig.)

  11. Magnetic resonance imaging of living systems by remote detection

    Science.gov (United States)

    Wemmer, David; Pines, Alexander; Bouchard, Louis; Xu, Shoujun; Harel, Elad; Budker, Dmitry; Lowery, Thomas; Ledbetter, Micah

    2013-10-29

    A novel approach to magnetic resonance imaging is disclosed. Blood flowing through a living system is prepolarized, and then encoded. The polarization can be achieved using permanent or superconducting magnets. The polarization may be carried out upstream of the region to be encoded or at the place of encoding. In the case of an MRI of a brain, polarization of flowing blood can be effected by placing a magnet over a section of the body such as the heart upstream of the head. Alternatively, polarization and encoding can be effected at the same location. Detection occurs at a remote location, using a separate detection device such as an optical atomic magnetometer, or an inductive Faraday coil. The detector may be placed on the surface of the skin next to a blood vessel such as a jugular vein carrying blood away from the encoded region.

  12. Central nervous system lymphoma: magnetic resonance imaging features at presentation

    Directory of Open Access Journals (Sweden)

    Ricardo Schwingel

    2012-02-01

    Full Text Available OBJECTIVE: This paper aimed at studying presentations of the central nervous system (CNS lymphoma using structural images obtained by magnetic resonance imaging (MRI. METHODS: The MRI features at presentation of 15 patients diagnosed with CNS lymphoma in a university hospital, between January 1999 and March 2011, were analyzed by frequency and cross tabulation. RESULTS: All patients had supratentorial lesions; and four had infra- and supratentorial lesions. The signal intensity on T1 and T2 weighted images was predominantly hypo- or isointense. In the T2 weighted images, single lesions were associated with a hypointense signal component. Six patients presented necrosis, all of them showed perilesional abnormal white matter, nine had meningeal involvement, and five had subependymal spread. Subependymal spread and meningeal involvement tended to occur in younger patients. CONCLUSION: Presentations of lymphoma are very pleomorphic, but some of them should point to this diagnostic possibility.

  13. Coordination Chemistry of SCS PdII Pincer Systems

    NARCIS (Netherlands)

    van Manen, H.J.; Nakashima, Kazuaki; Nakashima, K.; Shinkai, Seiji; Kooijman, Huub; Spek, Anthony L.; van Veggel, F.C.J.M.; Reinhoudt, David

    2000-01-01

    We have studied the coordination of substituted pyridines, and phosphorus- and sulfur-containing ligands to an SCS PdII pincer system. These ligands coordinate to PdII (trans to the cyclopalladated aryl group) by quantitative substitution of the labile acetonitrile ligand in complex 1. Competition

  14. Subcellular localization and paramagnetic properties of signals observed in Krebs II ascites cells by electron spin resonance spectroscopy

    International Nuclear Information System (INIS)

    Lloveras, J.; Vincensini, P.; Ribbes, G.; Record, M.; Ferre, G.; Douste-Blazy, L.; Pescia, J.

    1980-01-01

    Subcellular fractions of Krebs II ascites cells were examined by Electron Spin Resonance spectroscopy. Three signals were observed: (1) one at g = 2.005 associated with organic free radicals; (2) another at g = 2.01 formed by three peaks with a hyperfine splitting of 16 G; and (3) a third at g = 2.03, observed only in the particulate fraction 40,000 x g (30 min) and in the cytosol. This latter signal, of endogenous origin, seems similar to the one which is assigned in the literature to dinitrosyl-non-hem-iron complexes, and the role of such complexes in the carcinogenic process is often emphasized. Therefore, Krebs II ascites cells appear to be a useful model for investigating the endogenous 2.03 complex in relation to its localization and nature

  15. An in situ resonance Raman and infrared spectroscopic study of hexacyanoferrate (II) ion adsorbed to aqueous colloidal TiO 2

    Science.gov (United States)

    Umapathy, S.; McQuillan, A. J.; Hester, R. E.

    1990-06-01

    Resonance Raman and Fourier-transform infrared spectroscopies have been used to study the charge-transfer reactions of adsorbed hexacyanoferrate(II) on colloidal TiO 2. The spectroscopic results are analysed in terms of the molecular symmetry imposed by the various possible orientations of hexacyanoferrate(II) on the TiO 2 surface. It is concluded that the hexacyanoferrate(II) is adsorbed onto colloidal TiO 2 via either one or two CN groups.

  16. Resonant Frequency Control For the PIP-II Injector Test RFQ: Control Framework and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, A. L. [Colorado State U.; Biedron, S. G.; Milton, S. V.; Bowring, D.; Chase, B. E.; Edelen, J. P.; Nicklaus, D.; Steimel, J.

    2016-12-16

    For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over the detuning, minimal manual intervention, and fast trip recovery is desired. In addition, having active control over both the walls and vanes provides a wider tuning range. For this, we intend to use model predictive control (MPC). To facilitate these objectives, we developed a dedicated control framework that handles higher-level system decisions as well as executes control calculations. It is written in Python in a modular fashion for easy adjustments, readability, and portability. Here we describe the framework and present the first control results for the PI-Test RFQ under pulsed and CW operation.

  17. A fluorescence detected magnetic resonance investigation of the carotenoid triplet states associated with Photosystem II of isolated spinach thylakoid membranes

    CERN Document Server

    Santabarbara, S; Carbonera, D; Heathcote, P

    2005-01-01

    The carotenoid triplet populations associated with the fluorescence emission chlorophyll forms of Photosystem II have been investigated in isolated spinach thylakoid membranes by means of fluorescence detected magnetic resonance in zero field (FDMR). The spectra collected in the 680-690 nm emission range, have been fitted by a global analysis procedure. At least five different carotenoid triplet states coupled to the terminal emitting chlorophyll forms of PS II, peaking at 682 nm, 687 nm and 692 nm, have been characterised. The triplets associated with the outer antenna emission forms, at 682 nm, have zero field splitting parameters D = 0.0385 cm/sup -1/, E = 0.00367 cm/sup -1/; D = 0.0404 cm/sup -1/, E = 0.00379 cm/sup -1/ and D = 0.0386 cm/sup -1/, E = 0.00406 cm/sup -1/ which are very similar to those previously reported for the xanthophylls of the isolated LHC II complex. Therefore the FDMR spectra recorded in this work provide insights into the organisation of the LHC II complex in the unperturbed enviro...

  18. Ground Enterprise Management System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Emergent Space Technologies Inc. proposes to develop the Ground Enterprise Management System (GEMS) for spacecraft ground systems. GEMS will provide situational...

  19. Development of resonance-enhanced multiphoton ionization system

    International Nuclear Information System (INIS)

    Naik, P.D.; Upadhyaya, Hari P.; Kumar, Awadhesh; Bajaj, P.N.; Sinha, A.K.; Bhatt, S.; Gupta, M.D.P.

    2009-05-01

    Radiation and Photochemistry Division has developed a Molecular Beam-Resonance Enhanced Multiphoton Ionization-Time-of-Flight spectrometer, a highly sensitive and selective analytical detection system, for investigation of photodissociation dynamics of isolated molecules. In this system, the molecular beam is intersected in the extraction region of a Wiley-McLaren type Time-of-Flight mass spectrometer by the photolysis laser beam, propagating perpendicular to both the molecular beams and the Time-of-Flight tube. The probe (ionization) laser beam counter propagating to the photolysis beam, ionizes the stable products and the radicals produced on photodissociation. The important features of the system, namely, the resolution and the detection limit, have been determined from the studies of aniline molecular beam, generated by seeding 1% aniline in helium. For the present configuration, using one metre long flight tube, the resolution has been found to be about 400, and detection limit is better than 106 species per cm 3 . The integrity of the set-up is obtained from the photodissociation dynamics studies of bromoform. (author)

  20. A Comet Surface Sample Return System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase II investigation will focus on the development of spacecraft systems required to obtain a sample from the nucleus of a comet, hermetically seal...

  1. Variable Conductance Heat Pipes for Radioisotope Stirling Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall technical objective of the proposed Phase II program is to complete a system-level demonstration to show the capability and benefits of integrating this...

  2. Electron scattering from gas phase cis-diamminedichloroplatinum(II): Quantum analysis of resonance dynamics

    Science.gov (United States)

    Carey, Ralph; Lucchese, Robert R.; Gianturco, F. A.

    2013-05-01

    We present scattering calculations of electron collisions with the platinum-containing compound cis-diamminedichloroplatinum (CDDP), commonly known as cisplatin, between 0.5 eV and 6 eV, and the corresponding isolated Pt atom from 0.1 eV to 10 eV. We find evidence of resonances in e--CDDP scattering, using an ab initio description of the target. We computed scattering matrix elements from equations incorporating exchange and polarization effects through the use of the static-exchange plus density functional correlation potential. Additionally, we made use of a purely local adiabatic model potential that allows Siegert eigenstates to be calculated, thereby allowing inspection of the possible resonant scattering wave functions. The total cross section for electron scattering from (5d10) 1S Pt displays a large magnitude, monotonic decay from the initial collision energies, with no apparent resonance scattering features in any scattering symmetry. By contrast, the e--CDDP scattering cross section shows a small feature near 3.8 eV, which results from a narrow, well localized resonance of b2 symmetry. These findings are then related to the possible electron-mediated mechanism of the action of CDDP on DNA replication as suggested by recent experiments.

  3. Resonance assignment of PsbP: an extrinsic protein from photosystem II of Spinacia oleracea

    Czech Academy of Sciences Publication Activity Database

    Rathner, A.; Chandra, K.; Rathner, P.; Horničáková, M.; Schlagnitweit, J.; Kohoutová, Jaroslava; Ettrich, Rüdiger; Müller, N.

    2015-01-01

    Roč. 9, č. 2 (2015), s. 341-346 ISSN 1874-2718 Institutional support: RVO:61388971 Keywords : PsbP * Photosystem II * Oxygen evolving complex Subject RIV: EE - Microbiology, Virology Impact factor: 0.687, year: 2015

  4. Acoustic Resonance Spectroscopy (ARS) Munition Classification System enhancements. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Vela, O.A.; Huggard, J.C.

    1997-09-18

    Acoustic Resonance Spectroscopy (ARS) is a non-destructive evaluation technology developed at the Los Alamos National Laboratory (LANL). This technology has resulted in three generations of instrumentation, funded by the Defense Special Weapons Agency (DSWA), specifically designed for field identification of chemical weapon (CW) munitions. Each generation of ARS instrumentation was developed with a specific user in mind. The ARS1OO was built for use by the U.N. Inspection Teams going into Iraq immediately after the Persian Gulf War. The ARS200 was built for use in the US-Russia Bilateral Chemical Weapons Treaty (the primary users for this system are the US Onsite Inspection Agency (OSIA) and their Russian counterparts). The ARS300 was built with the requirements of the Organization for the Prohibition of Chemical Weapons (OPCW) in mind. Each successive system is an improved version of the previous system based on learning the weaknesses of each and, coincidentally, on the fact that more time was available to do a requirements analysis and the necessary engineering development. The ARS300 is at a level of development that warrants transferring the technology to a commercial vendor. Since LANL will supply the computer software to the selected vendor, it is possible for LANL to continue to improve the decision algorithms, add features where necessary, and adjust the user interface before the final transfer occurs. This paper describes the current system, ARS system enhancements, and software enhancements. Appendices contain the Operations Manual (software Version 3.01), and two earlier reports on enhancements.

  5. Dynamic characteristics of a 20 kHz resonant power system - Fault identification and fault recovery

    Science.gov (United States)

    Wasynczuk, O.

    1988-01-01

    A detailed simulation of a dc inductor resonant driver and receiver is used to demonstrate the transient characteristics of a 20 kHz resonant power system during fault and overload conditions. The simulated system consists of a dc inductor resonant inverter (driver), a 50-meter transmission cable, and a dc inductor resonant receiver load. Of particular interest are the driver and receiver performance during fault and overload conditions and on the recovery characteristics following removal of the fault. The information gained from these studies sets the stage for further work in fault identification and autonomous power system control.

  6. Alternative pathways for angiotensin II generation in the cardiovascular system

    Directory of Open Access Journals (Sweden)

    C. Becari

    2011-09-01

    Full Text Available The classical renin-angiotensin system (RAS consists of enzymes and peptides that regulate blood pressure and electrolyte and fluid homeostasis. Angiotensin II (Ang II is one of the most important and extensively studied components of the RAS. The beneficial effects of angiotensin converting enzyme (ACE inhibitors in the treatment of hypertension and heart failure, among other diseases, are well known. However, it has been reported that patients chronically treated with effective doses of these inhibitors do not show suppression of Ang II formation, suggesting the involvement of pathways alternative to ACE in the generation of Ang II. Moreover, the finding that the concentration of Ang II is preserved in the kidney, heart and lungs of mice with an ACE deletion indicates the important role of alternative pathways under basal conditions to maintain the levels of Ang II. Our group has characterized the serine protease elastase-2 as an alternative pathway for Ang II generation from Ang I in rats. A role for elastase-2 in the cardiovascular system was suggested by studies performed in heart and conductance and resistance vessels of normotensive and spontaneously hypertensive rats. This mini-review will highlight the pharmacological aspects of the RAS, emphasizing the role of elastase-2, an alternative pathway for Ang II generation.

  7. Stochastic resonance for a metapopulation system driven by multiplicative and additive colored noises

    International Nuclear Information System (INIS)

    Wang Kang-Kang; Liu Xian-Bin

    2014-01-01

    We investigate the stochastic resonance (SR) phenomenon induced by the periodic signal in a metapopulation system with colored noises. The analytical expression of signal-to-noise is derived in the adiabatic limit. By numerical calculation, the effects of the addictive noise intensity, the multiplicative noise intensity and two noise self-correlation times on SNR are respectively discussed. It shows that: (i) in the case that the addictive noise intensity M takes a small value, a SR phenomenon for the curve of SNR appears; however, when M takes a large value, SNR turns into a monotonic function on the multiplicative noise intensity Q. (ii) The resonance peaks in the plots of the multiplicative noise intensity Q versus its self-correlation time τ 1 and the addictive noise intensity M versus its self-correlation time τ 2 translate in parallel. Meanwhile, a parallel translation also appears in the plots of τ 1 versus Q and τ 2 versus M. (iii) The interactive effects between self-correlation times τ 1 and τ 2 are opposite. (general)

  8. Scalable Gravity Offload System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is a scalable gravity off-load system that enables controlled integrated testing of Surface System elements such as rovers, habitats, and...

  9. Mars Integrated Propellant Production System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Integrated Mars In-Situ Propellant Production System (IMISPPS) is an end-to-end system that will produce rocket propellant on Mars from CO2 in the Martian...

  10. Statistics of resonances in one-dimensional continuous systems

    Indian Academy of Sciences (India)

    Our main result is an integral representation for the DOR which involves the probability density function of the ... of the scattering matrix S(E) in the complex energy plane. Resonances correspond to poles En ... conditions leads to complex eigenvalues En which correspond to resonances [1,2]. For a recent lucid discussion of ...

  11. Minimizing Risk of Nephrogenic systemic fibrosis in Cardiovascular Magnetic Resonance

    Directory of Open Access Journals (Sweden)

    Reiter Theresa

    2012-05-01

    Full Text Available Abstract Nephrogenic Systemic Fibrosis is a rare condition appearing only in patients with severe renal impairment or failure and presents with dermal lesions and involvement of internal organs. Although many cases are mild, an estimated 5 % have a progressive debilitating course. To date, there is no known effective treatment thus stressing the necessity of ample prevention measures. An association with the use of Gadolinium based contrast agents (GBCA makes Nephrogenic Systemic Fibrosis a potential side effect of contrast enhanced magnetic resonance imaging and offers the opportunity for prevention by limiting use of gadolinium based contrast agents in renal failure patients. In itself toxic, Gadolinium is embedded into chelates that allow its safe use as a contrast agent. One NSF theory is that Gadolinium chelates distribute into the extracellular fluid compartment and set Gadolinium ions free, depending on multiple factors among which the duration of chelates exposure is directly related to the renal function. Major medical societies both in Europe and in North America have developed guidelines for the usage of GBCA. Since the establishment of these guidelines and the increased general awareness of this condition, the occurrence of NSF has been nearly eliminated. Giving an overview over the current knowledge of NSF pathobiochemistry, pathogenesis and treatment options this review focuses on the guidelines of the European Medicines Agency, the European Society of Urogenital Radiology, the FDA and the American College of Radiology from 2008 up to 2011 and the transfer of this knowledge into every day practice.

  12. Fluorescence Resonance Energy Transfer Systems in Supramolecular Macrocyclic Chemistry

    Directory of Open Access Journals (Sweden)

    Xin-Yue Lou

    2017-09-01

    Full Text Available The fabrication of smart materials is gradually becoming a research focus in nanotechnology and materials science. An important criterion of smart materials is the capacity of stimuli-responsiveness, while another lies in selective recognition. Accordingly, supramolecular host-guest chemistry has proven a promising support for building intelligent, responsive systems; hence, synthetic macrocyclic hosts, such as calixarenes, cucurbiturils, cyclodextrins, and pillararenes, have been used as ideal building blocks. Meanwhile, manipulating and harnessing light artificially is always an intensive attempt for scientists in order to meet the urgent demands of technological developments. Fluorescence resonance energy transfer (FRET, known as a well-studied luminescent activity and also a powerful tool in spectroscopic area, has been investigated from various facets, of which the application range has been broadly expanded. In this review, the innovative collaboration between FRET and supramolecular macrocyclic chemistry will be presented and depicted with typical examples. Facilitated by the dynamic features of supramolecular macrocyclic motifs, a large variety of FRET systems have been designed and organized, resulting in promising optical materials with potential for applications in protein assembly, enzyme assays, diagnosis, drug delivery monitoring, sensing, photosynthesis mimicking and chemical encryption.

  13. On split Lie triple systems II

    Indian Academy of Sciences (India)

    Lie triple system with a coherent 0-root space is the direct sum of the family of its minimal ideals, each one being a simple split Lie triple system, and the simplicity of T is characterized. In the present paper we extend these results to arbitrary split Lie triple systems with no restrictions on their 0-root spaces. Keywords.

  14. White-Light Whispering Gallery Mode Optical Resonator System and Method

    Science.gov (United States)

    Matsko, Andrey B. (Inventor); Savchenkov, Anatoliy A. (Inventor); Maleki, Lute (Inventor)

    2009-01-01

    An optical resonator system and method that includes a whispering-gallery mode (WGM) optical resonator that is capable of resonating across a broad, continuous swath of frequencies is provided. The optical resonator of the system is shaped to support at least one whispering gallery mode and includes a top surface, a bottom surface, a side wall, and a first curved transition region extending between the side wall and the top surface. The system further includes a coupler having a coupling surface which is arranged to face the transition region of the optical resonator and in the vicinity thereof such that an evanescent field emitted from the coupler is capable of being coupled into the optical resonator through the first curved transition region

  15. The formation of the Mg II resonance lines in the solar atmosphere

    International Nuclear Information System (INIS)

    Greve, A.

    1978-01-01

    Synthetic LTE profiles, calculated for the HSRA, VAL, and the so-called 'Ca II and Mg II' model atmospheres introduced by Ayres and Linsky, are compared with the Mg II profiles (2760 A < approximately lambda < approximately 2820 A) of the average quiet Sun observed at μ = 1.0, 0.6 and 0.43. As a prerequisite for calculating profiles, for each model atmosphere the author derives empirically the total opacity as function of the height so that the continuum intensity and limb darkening observed at lambda 2660 A and lambda 2940 A is reproduced. For each model atmosphere the most appropriate value of Aγ* (A: abundance of Mg, γ*: multiplying factor applied to the collisional broadening calculated from Unsold's expression) is derived from the best fit of the calculated profiles and the central parts of the profiles observed at μ = 1.0 and 0.6. These values Aγ* reproduce the far wings of the Mg II flux profile. The comparison of the computed profiles and the observed profiles indicates that none of the one-component, static model atmospheres of the average quiet Sun reproduces the central parts of the Mg II profiles in their centre to limb variation. The proposal by Ayres and Linsky of higher minimum temperatures is not supported by our observations. (Auth.)

  16. Rapid Automated Mission Planning System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an automated UAS mission planning system that will rapidly identify emergency (contingency) landing sites, manage contingency routing, and...

  17. Flow imaging of the cardiovascular system using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Imai, Hitoshi; Sakakibara, Makoto; Sunami, Yuko

    1988-01-01

    Blood flow images by magnetic resonance imaging (MRI) using a 0.25 T unit were evaluated for nine normal volunteers and 108 subjects with a variety of cardiovascular abnormalities. Using the non-gated short-spin echo (SE) technique, blood flow in the cardiovascular systems was not imaged in the normal volunteers. Using end-systolic and end-diastolic SE techniques for the normal subjects, blood flow in the cardiac chambers was not clearly imaged. Blood flow in the ascending aorta and aortic arch often did not appear in the gated SE images of the normal subjects. However, blood flow in the descending aorta was often observed in the gated SE images. Blood flow imaging was demonstrated by both non-gated and gated SE techniques in regions where blood flow was relatively slow; for example, in the left atrium of mitral stenosis, in an aortic aneurysm, in a false lumen of an aortic dissection, and in the left ventricle having old myocardial infarction. Using the non-gated inversion recovery (IR) technique, no blood flow was imaged in the cardiovascular system except in the left atrium of one case with mitral stenosis. Using the non-gated short SE technique, there was good correlation between the thrombus formation and the presence of blood flow images in the left atria of 17 patients with mitral stenosis, and in the aneurysmal portions of the aorta or in the false lumens of aortic dissection of 18 patients. It was suggested that mural thrombi in such diseases were related to the relatively slow blood flow. Blood flow imaging easily distinguished stagnant blood flow from mural thrombi using non-gated short SE, end-systolic SE, and IR techniques. Thus, blood flow imaging using MRI should become an important means of evaluating the cardiovascular system. (author)

  18. Electron paramagnetic resonance in myoglobin single crystals doped with Cu(II) : conformational changes

    International Nuclear Information System (INIS)

    Nascimento, O.R.

    1976-03-01

    Single crystals of sperm whale met-Myoglobin were doped with Cu (II) by immersion in a saturaded solution of NH 3 (SO 4 ) containing diluted Cu (SO 4 ).Two isotropic EPR spectra with different parameters and three anisotropic EPR spectra corresponding to three distinct types of Cu(II) : Mb complexes were identified. A fitting of the angular variation of the EPR spectrum of one of the complexes named here Cu(II)A : Mb was done using a spin Hamiltonian with axial symmetry calculated up to second order which gave the EPR hyperfine parameters.A study of the thermal variation of the complex Cu (II)A : Mb EPR spectrum in the temperature range of 25 0 C to 55 0 C allowed an identification of a conformational variation of the molecule the spectrum evolved from the anisotropic to isotropic spectrum with different parameters. A model of the Cu(II)A : Mb complex is proposed to explain the conformational change of the molecule by means of EPR spectra before and after thermal treatment. The isotropic spectrum obtained with the crystal at 55 0 C presents the EPR parameters very similar to the same parameters obtained with the Cu (II) : Mb complex in aqueous solution at 77 0 K, whereas the isotropic spectra parameters obtained with the dried crystal are quite different. It was possible to identify two different tertiary structures of the myoglobin molecule : one corresponding to the molecule in the crystal at 55 0 C and other to the dry crystal. A slight difference in the crystalline and solution structure of the myoglobin mollecule is observed. (Author) [pt

  19. Magnetic resonance imaging in neuropsychiatric systemic lupus erythematosus: current state of the art and novel approaches.

    Science.gov (United States)

    Postal, M; Lapa, A Tamires; Reis, F; Rittner, L; Appenzeller, S

    2017-04-01

    Systemic lupus erythematosus is a chronic, inflammatory, immune-mediated disease affecting 0.1% of the general population. Neuropsychiatric manifestations in systemic lupus erythematosus have been more frequently recognized and reported in recent years, occurring in up to 75% of patients during the disease course. Magnetic resonance imaging is known to be a useful tool for the detection of structural brain abnormalities in neuropsychiatric systemic lupus erythematosus patients because of the excellent soft-tissue contrast observed with MRI and the ability to acquire multiplanar images. In addition to conventional magnetic resonance imaging techniques to evaluate the presence of atrophy and white matter lesions, several different magnetic resonance imaging techniques have been used to identify microstructural or functional abnormalities. This review will highlight different magnetic resonance imaging techniques, including the advanced magnetic resonance imaging methods used to determine central nervous system involvement in systemic lupus erythematosus.

  20. Two-dimensional nuclear magnetic resonance of quadrupolar systems

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shuanhu [Univ. of California, Berkeley, CA (United States)

    1997-09-01

    This dissertation describes two-dimensional nuclear magnetic resonance theory and experiments which have been developed to study quadruples in the solid state. The technique of multiple-quantum magic-angle spinning (MQMAS) is extensively reviewed and expanded upon in this thesis. Specifically, MQMAS is first compared with another technique, dynamic-angle spinning (DAS). The similarity between the two techniques allows us to extend much of the DAS work to the MQMAS case. Application of MQMAS to a series of aluminum containing materials is then presented. The superior resolution enhancement through MQMAS is exploited to detect the five- and six-coordinated aluminum in many aluminosilicate glasses. Combining the MQMAS method with other experiments, such as HETCOR, greatly expands the possibility of the use of MQMAS to study a large range of problems and is demonstrated in Chapter 5. Finally, the technique switching-angle spinning (SAS) is applied to quadrupolar nuclei to fully characterize a quadrupolar spin system in which all of the 8 NMR parameters are accurately determined. This dissertation is meant to demonstrate that with the combination of two-dimensional NMR concepts and new advanced spinning technologies, a series of multiple-dimensional NMR techniques can be designed to allow a detailed study of quadrupolar nuclei in the solid state.

  1. Excited, bound and resonant positron-atom systems

    Energy Technology Data Exchange (ETDEWEB)

    Bromley, M W J [Department of Physics and Computational Science Research Center, San Diego State University, San Diego CA 92182 (United States); Mitroy, J, E-mail: mbromley@physics.sdsu.ed [ARC Centre for Antimatter-Matter Studies and Faculty of Education, Health and Science, Charles Darwin University, Darwin NT 0909 (Australia)

    2010-01-01

    Calculations have demonstrated that eleven neutral atoms can bind positrons, while many more can bind positronium. This is a short review of recent progress made in understanding some of the underlying mechanisms. The emphasis here being on configuration interaction calculations with excited state configurations. These have demonstrated the existence of a {sup 2}P{sup o} excited state of e{sup +}Ca, which consists predominantly of a positronium cluster orbiting the Ca{sup +} ion in the L = 1 partial wave. Preliminary results are presented of excited state positron binding to a model alkali atom, where the excited {sup 1}P{sup o} states are stable over a limited region. Implications for the unnatural parity, {sup 2,4}S{sup o}, states of PsH, LiPs, NaPs and KPs are also discussed. The e{sup +}Mg, e{sup +}Cu, e{sup +}Zn and e{sup +}Cd systems show a lack of a {sup 2}P{sup o} excited state, each instead possessing a low-energy p-wave shape resonance of varying strength.

  2. Clenbuterol Assay by Spectral Imaging Surface Plasmon Resonance Biosensor System.

    Science.gov (United States)

    Wu, Yichuan; Yao, Manwen; Fang, Xiangyi; Yang, Yucong; Cheng, Xiaoli

    2015-11-01

    To prevent illegal use of clenbuterol and for quality control in the food industry, more efficient and reliable methods for clenbuterol detection are needed. In this study, clenbuterol was detected using a spectral imaging surface plasmon resonance sensor system via two inhibition methods: (1) the target site compensation method, in which anti-clenbuterol antibody was immobilized on the sensor chip as a bioprobe and (2) the solution competition method in which a clenbuterol-BSA conjugate was immobilized on the sensor chip as the bioprobe. The detectable clenbuterol concentration ranged between 6.25 and 100 μg/mL for both methods. The clenbuterol limit of detection for the target site compensation method and solution competition method are estimated to be 6.7 and 4.5 μg/mL, respectively. The proposed methods were successfully applied to the detection of clenbuterol molecules and were found to have high specificity and high-throughput and were label free and operationally convenient.

  3. Towards the invisible cryogenic system for Magnetic Resonance Imaging

    Science.gov (United States)

    Steinmeyer, F.; Retz, P. W.; White, K.; Lang, A.; Stautner, W.; Smith, P. N.; Gilgrass, G.

    2002-05-01

    With about 10,000 Magnetic Resonance Imaging (MRI) systems installed worldwide, helium cooled magnets have become familiar equipment in hospitals and imaging centers. Patients and operators are only aware of the hissing sound of the Gifford-MacMahon refrigerator. Service technicians, however, still work with cryogenic fluids and cold gases, e.g. for replenishing the helium reservoir, inserting retractable current leads for magnet ramps, or replacing burst disks after a magnet quench. We will describe the steps taken at Oxford Magnet Technology towards the ultimate goal of a superconducting magnet being as simple as a household fridge. Early steps included the development of resealing quench valves, as well as permanently installed transfer siphons that only open when fully cooled to 4K. On recently launched 1.5 Tesla solenoid magnets, 500 A current leads are permanently fixed into the service turret, with hardly any boil-off penalty (40-50 cc/hr total). Ramping of the magnet has been fully automated, including electronic supervision of the gas-cooled current leads. One step ahead, the 1 Tesla High Field Open magnet is refrigerated by a single 4K Gifford MacMahon coldhead, relieving the user from the necessity to refill with helium. Our conduction cooled 0.2 Tesla HTS magnet testbed does not require liquid cryogens at any time in its life, including initial cool-down.

  4. The Thorvald II Agricultural Robotic System

    Directory of Open Access Journals (Sweden)

    Lars Grimstad

    2017-09-01

    Full Text Available This paper presents a novel and modular approach to agricultural robots. Food production is highly diverse in several aspects. Even farms that grow the same crops may differ in topology, infrastructure, production method, and so on. Modular robots help us adapt to this diversity, as they can quickly be configured for various farm environments. The robots presented in this paper are hardware modular in the sense that they can be reconfigured to obtain the necessary physical properties to operate in different production systems—such as tunnels, greenhouses and open fields—and their mechanical properties can be adapted to adjust for track width, power requirements, ground clearance, load capacity, and so on. The robot’s software is generalizing to work with the great variation of robot designs that can be realized by assembling hardware modules in different configurations. The paper presents several novel ideas for agricultural robotics, as well as extensive field trials of several different versions of the Thorvald II platform.

  5. Removal of Pb(II), Cu(II) and Cd(II) from aqueous solution by some fungi and natural adsorbents in single and multiple metal systems

    International Nuclear Information System (INIS)

    Shoaib, A.; Badar, T.; Aslam, N.

    2011-01-01

    Six fungal and 10 natural biosorbents were analyzed for their Cu(II), Cd(II) and Pb(II) uptake capacity from single, binary and ternary metal ion system. Preliminary screening biosorption of assays revealed 2 fungi (Aspergillus niger and Cunninghamella echinulata) and three natural [Cicer arietinum husk, Moringa oleifera flower and soil (clay)] adsorbents hold considerable high adsorption efficiency and capacity for 3 meta l ions amongst the adsorbents. Further biosorption trials with five elected adsorbents showed a considerable reduction in metal uptake capability of adsorbents in binary- and ternary systems as compared to singly metal system. Cd(II) manifested the highest inhibitory effect on the biosorption of other metal ions, followed by Pb(II) and Cu(II). On account of metal preference, the selectivity order for metal ion towards the studied biomass matrices was Pb(II) (40-90%) > Cd(II) (2-53%) > Cu(II) (2-30%). (author)

  6. Simulation of optical soliton control in micro- and nanoring resonator systems

    CERN Document Server

    Daud, Suzairi; Ali, Jalil

    2015-01-01

    This book introduces optical soliton control in micro- and nanoring resonator systems. It describes how the ring resonator systems can be optimized as optical tweezers for photodetection by controlling the input power, ring radii and coupling coefficients of the systems. Numerous arrangements and configurations of micro and nanoring resonator systems are explained. The analytical formulation and optical transfer function for each model and the interaction of the optical signals in the systems are discussed. This book shows that the models designed are able to control the dynamical behaviour of generated signals.

  7. Tactile Data Entry System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Building on our successful Phase I Tactile Data Entry program, Barron Associates proposes development of a Glove-Enabled Computer Operations (GECO) system to permit...

  8. Lunar Materials Handling System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Materials Handling System (LMHS) is a method for transfer of lunar soil into and out of process equipment in support of in situ resource utilization...

  9. Wearable Health Monitoring Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  10. Plasma Air Decontamination System (PADS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Plasma Air Decontamination System (PADS) is a trace contaminant control device based on non-thermal atmospheric-pressure plasma technology. Compared to...

  11. Mars Aqueous Processing System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Aqueous Processing System (MAPS) is a novel technology for recovering oxygen, iron, and other constituents from lunar and Mars soils. The closed-loop...

  12. Lunar Sulfur Capture System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Sulfur Capture System (LSCS) is an innovative method to capture greater than 90 percent of sulfur gases evolved during thermal treatment of lunar soils....

  13. Carbon Monoxide Silicate Reduction System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Carbon Monoxide Silicate Reduction System (COSRS) is a novel technology for producing large quantities of oxygen on the Moon. Oxygen yields of 15 kilograms per...

  14. Advanced Green Micropropulsion System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Systima in collaboration with University of Washington is developing a high performance injection system for advanced green monopropellant AF-M315E micropropulsion...

  15. Electronic construction collaboration system -- phase II.

    Science.gov (United States)

    2010-06-01

    During the first year of research, work was completed to identify Iowa DOT needs for web-based project management system (WPMS) : and evaluate how commercially available solutions could meet these needs. Researchers also worked to pilot test custom d...

  16. Enhanced Brine Dewatering System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of the Enhanced Brine Dewatering System (EBDS) is to provide a scalable means of completely recovering usable water from byproducts created by reverse...

  17. Influence of external fields and environment on the dynamics of a phase-qubit-resonator system

    International Nuclear Information System (INIS)

    Berman, G. P.; Chumak, A. A.

    2011-01-01

    We analyze the dynamics of a qubit-resonator system coupled with a thermal bath and external electromagnetic fields. Using the evolution equations for the set of Heisenberg operators that describe the whole system, we derive an expression for the resonator field, accounting for the resonator-drive, -bath, and -qubit interaction. The renormalization of the resonator frequency caused by the qubit-resonator interaction is accounted for. Using solutions for the resonator field, we derive the equation describing qubit dynamics. The influence of the qubit evolution during measurement time on the fidelity of a single-shot measurement is studied. The relation between fidelity and measurement time is shown explicitly. Also, an expression describing relaxation of the superposition qubit state toward its stationary value is derived. The possibility of controlling this state by varying the amplitude and frequency of drive is shown.

  18. The validity of the RWA and gate operation speedup by violating RWA in resonant-driven qubit systems

    Science.gov (United States)

    Song, Yang

    The rotating wave approximation (RWA) is ubiquitously used in understanding (quasi)resonant driven systems and designing pulses for state evolution. Following the practice in atomic and NMR physics, a wide range of semiconducting qubit systems are driven resonantly to manipulate the qubit, including single-spin/resonant exchange (RX)/various singlet-triplet(ST)/spin-charge hybrid qubits. The purpose of this talk is twofold: (I) Examine the validity of RWA in different qubit systems and analyze the error in terms of quantum computation; (II) Present faster gate operations by going into RWA-invalid regime for resonant-driven qubits (esp. for ST and RX types). We measure the RWA-induced infidelity and discuss it in view of the fault-tolerant error correction threshold and operation speeds. Applying the analytical extension (two orders higher than RWA) greatly reduces the infidelity, in the regime where the RWA is attempted to be used. Moreover, we show that the resonant-driven system is not limited by the Rabi-like weak coupling limit and the associated slow gate speed, much smaller than the level splitting (e.g., the small Zeeman energy gradient in ST qubits). We demonstrate the universal one qubit gates for driving strength up to a few level splitting, achieving fast control with only simple sinusoidal pulses. We also solve for the `shifted sinusoidal' pulses needed for ST qubits where the exchange coupling cannot change signs. In collaboration with Xin Wang, Jason Kestner and Sankar Das Sarma, and supported by LPS-MPO-CMTC and IARPA-MQCO.

  19. Acceptance testing and evaluation of TOPAZ II space power systems

    Science.gov (United States)

    Follis, Hoby D.; Schmidt, Glen; Ogloblin, Boris; Sinkevich, Valery G.

    1995-01-01

    The Thermionic System Evaluation Test (TSET) facility, part of the TOPAZ International Program, in Albuquerque, New Mexico is currently testing Russian TOPAZ II space power systems (Wold 1993). The TOPAZ International Program has received six TOPAZ II Space Nuclear power Reactors. Two of these reactors (Eh-43 and Eh-44) are considered ``flight quality.'' A considerable transfer of technology has occurred during the preparations for acceptance testing of the Eh-43 and Eh-44 TOPAZ II reactors. The Eh-43 and Eh-44 are new systems that have not undergone any testing and require the coolant loop and gas cavities to be filled. The new systems will undergo an acceptance process that ranges from receipt inspection to thermal vacuum testing. The knowledge we gain from these tests will help determine the use of this technology in future applications.

  20. Optical pulling force and conveyor belt effect in resonator-waveguide system.

    Science.gov (United States)

    Intaraprasonk, Varat; Fan, Shanhui

    2013-09-01

    We present the theoretical condition and actual numerical design that achieves an optical pulling force in resonator-waveguide systems, where the direction of the force on the resonator is in the opposite direction to the input light in the waveguide. We also show that this pulling force can occur in conjunction with the lateral optical equilibrium effect, such that the resonator is maintained at the fixed distance from the waveguide while experiencing the pulling force.

  1. Assessment of Integrated Information System (IIS) in organization ...

    African Journals Online (AJOL)

    The assessment of Integrated Information System (IIS) in organisation is an important initiative to enable the Information System (IS) managers, as well as top management to understand the success status of their investment in IS integration efforts. However, without a proper assessment, an organisation will not know its IIS ...

  2. High quantum efficiency N-structure type-II superlattice mid-wavelength infrared detector with resonant cavity enhanced design

    Science.gov (United States)

    Wu, Haoyue; Xu, Yun; Li, Jian; Jiang, Yu; Bai, Lin; Yu, Hailong; Fu, Dong; Zhu, Haijun; Song, Guofeng

    2017-05-01

    We propose a resonant cavity enhanced (RCE) N-structure type-II superlattice (T2SL) mid-wavelength infrared (MWIR) photodetector which can be used for the detection of methane gas at 3.3 μm. The theoretical analysis of quantum efficiency (QE) shows that the peak QE can be enhanced from 0.45 to 0.80 at 3.3 μm after 12 period AlAs0.09Sb0.91/GaSb DBR is introduced to the N-structure T2SL detector and QE exhibits the narrow bandwidth characteristic near the target wavelength. By analyzing the refractive indices of different materials and the reflectance of different DBRs, we also discuss how to determine the component materials of quarter-wavelength DBR reflectors.

  3. Spontaneity and Equilibrium II: Multireaction Systems

    Science.gov (United States)

    Raff, Lionel M.

    2014-01-01

    The thermodynamic criteria for spontaneity and equilibrium in multireaction systems are developed and discussed. When N reactions are occurring simultaneously, it is shown that G and A will depend upon N independent reaction coordinates, ?a (a = 1,2, ..., N), in addition to T and p for G or T and V for A. The general criteria for spontaneity and…

  4. Förster Resonance Energy Transfer and Harvesting in II-VI Fractional Monolayer Structures

    Science.gov (United States)

    Shubina, T. V.; Semina, M. A.; Belyaev, K. G.; Rodina, A. V.; Toropov, A. A.; Ivanov, S. V.

    2017-07-01

    We report on Förster resonance energy transfer in the dense arrays of epitaxial quantum dots (QDs), formed by fractional monolayer CdSe insertions within a ZnSe matrix. In such arrays comprising the QDs of different sizes, the energy transfer can take place between the ground levels of small QDs and the excited levels of large radiating QDs, when these states are in resonance. This mechanism provides directional excitation of a limited number of the large QDs possessing the excited levels. It reveals itself by the shrinkage of photoluminescence (PL) bands and the appearance of the narrow single excitonic lines in micro-PL spectra. The strong shortening of characteristic PL decay times in the energy-donating QDs is observed when the distance between them and the energy-accepting QDs decreases. Photoluminescence excitation spectroscopy demonstrates the switching of the dominant energy transfer mechanism at the energy predicted by theoretical modeling of the excitonic levels in the QD arrays. Our results pave the way for engineering of the architecture of excitonic levels in the QD arrays to realize efficient nano-emitters.

  5. Design of the TJ-II remote participation system

    Science.gov (United States)

    Vega, J.; Sánchez, E.; López, A.; Portas, A.; Ochando, M.; Mollinedo, A.; Sánchez, A.; Ruiz, M.; López, S.; Barrera, E.

    2003-03-01

    The TJ-II remote participation design has focused initially on providing remote access to elements that depend exclusively on characteristics of the TJ-II environment: data acquisition, data access, and diagnostics control systems. Aspects related to advanced display tools, audio information from the control room or videoconference sessions can be addressed, at least in a first step, by using standard solutions. Remote access will be accomplished through http servers and web browsers as they are standard elements available on all platforms. Access security rests on a validation scheme in which users are identified through a username and password, these data being transferred in a secure way by using a secure socket layer (SSL). After username and password validation, the security system assigns a session ticket to the user, in which the user profile (access authorization list) is encoded. User profiles determine several access levels to the system. Such levels delimit the authorizations for accessing different services according to the allowed degree of interaction of remote users with the TJ-II environment. The ticket will be sent in every user query, in order to test user permission for the requested action. Services can be classified into five groups: Measurement channel setup, read/write access to the TJ-II databases (raw data, analyzed data, elaborated data, and relational databases), diagnostic control system monitoring/programming, advanced data acquisition system configuration and, finally, reading/writing information on TJ-II operation logbook. The TJ-II remote participation system is strongly coupled with the local data acquisition system.

  6. On split Lie triple systems II

    Indian Academy of Sciences (India)

    In the present paper we extend these results to arbitrary split Lie triple systems with no restrictions on their 0-root spaces. Author Affiliations. Antonio J Calderón Martín1 M Forero Piulestán1. Departamento de Matemáticas, Universidad de Cádiz, 11510 Puerto Real, Cádiz, Spain. Dates. Manuscript received: 24 June 2009 ...

  7. Overview of the TJ-II remote participation system

    International Nuclear Information System (INIS)

    Vega, J.; Sanchez, E.; Portas, A.; Pereira, A.; Mollinedo, A.; Munoz, J.A.; Ruiz, M.; Barrera, E.; Lopez, S.; Machon, D.; Castro, R.; Lopez, D.

    2006-01-01

    The TJ-II remote participation system (RPS) is focused on providing remote access to elements that depend exclusively on characteristics of the TJ-II environment: data acquisition, diagnostics control systems and TJ-II operation tracking. Four key points were taken into account prior to starting the software design: access security, software execution platforms, software maintenance and distribution and delivery of operation events. The first, access security, was addressed by means of a distributed authentication and authorization system, PAPI. Regarding the other points, the development was based on the use of web servers (due to their standard character, flexibility and scalability) and Java technologies (due to their open nature, security properties and technological maturity). Software deployment was prepared to make use of the Java Network Launching Protocol (JNLP). On-line message distribution was planned according to a message oriented middleware. At present, the TJ-II RPS manages over 1000 digitization channels and 20 diagnostic control systems. The TJ-II RPS architecture is flexible, scalable and powerful enough to be applied to distributed environments and, in particular, it could be used in the ITER environment

  8. Intraoperative OCT Imaging of the Argus II Retinal Prosthesis System.

    Science.gov (United States)

    Rachitskaya, Aleksandra V; Yuan, Alex; Marino, Meghan J; Reese, Jamie; Ehlers, Justis P

    2016-11-01

    Optimal placement of the Argus II Retinal Prosthesis System (Second Sight Medical Products, Sylmar, CA) is critical. Intraoperative optical coherence tomography (OCT) allows for intrasurgical visualization and confirmation of array placement. In this study, two different OCT systems were evaluated to assess the feasibility and utility of this technology during Argus II surgery. Intraoperative OCT was performed on five patients undergoing Argus II implantation at Cole Eye Institute from June 2015 to July 2016. The EnVisu portable OCT (Bioptigen, Morrisville, NC) and microscope-integrated RESCAN 700 (Zeiss, Oberkochen, Germany) intraoperative OCT systems were utilized. The EnVisu was used in three patients and the RESCAN 700 in three of the five patients. Following array tacking, intraoperative OCT was performed over the entire array including the edges and tack. Intraoperative OCT allowed for visualization of the array/retina interface. Microscope integration of the OCT system facilitated ease of focusing, real-time feedback, surgeon-directed OCT scanning to the areas of interest, and enhanced image quality at points of interest. Intraoperative imaging of the Argus II electrode array is feasible and provides information about electrode array-retina interface and distance to help guide a surgeon. Microscope integration of OCT appears to provide an optimal and efficient approach to intraoperative OCT during Argus II array placement. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:999-1003.]. Copyright 2016, SLACK Incorporated.

  9. MRI findings in central nervous system of neurofibromatosis-II

    International Nuclear Information System (INIS)

    Chen Maoen; Huang Suiqiao; Shen Jun; Hong Guobin; Wu Zhuo; Lin Xiaofeng

    2007-01-01

    Objective: To investigate the diagnostic value of MR imaging in central nervous system involvement of neurofibromatosis II. Methods: 7 patients with surgically and pathologically proved neurofibromatosis II were included. Their MR imaging findings and clinical features were retrospectively analyzed. Results: The main findings of 7 cases of neurofibraomaosis II on MR imaging included bilateral acoustic neurilemoma, multiple neurofibroma, meningioma and schwannoma. Among the 7 patients, Tl-weighted imaging after contrast enhancement displayed additional lesions which had been ignored on un-enhanced scan. Conclusion: MR imaging has advantages in the detection of central nervous sys- tem involvement of neurofibromatosis II with regard to its ability to show the lesions well, meanwhile displaying the size, morphology and signal features clearly. (authors)

  10. FISPACT-II: An Advanced Simulation System for Activation, Transmutation and Material Modelling

    Energy Technology Data Exchange (ETDEWEB)

    Sublet, J.-Ch., E-mail: jean-christophe.sublet@ukaea.uk [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Eastwood, J.W.; Morgan, J.G. [Culham Electromagnetics Ltd, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Gilbert, M.R.; Fleming, M.; Arter, W. [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2017-01-15

    Fispact-II is a code system and library database for modelling activation-transmutation processes, depletion-burn-up, time dependent inventory and radiation damage source terms caused by nuclear reactions and decays. The Fispact-II code, written in object-style Fortran, follows the evolution of material irradiated by neutrons, alphas, gammas, protons, or deuterons, and provides a wide range of derived radiological output quantities to satisfy most needs for nuclear applications. It can be used with any ENDF-compliant group library data for nuclear reactions, particle-induced and spontaneous fission yields, and radioactive decay (including but not limited to TENDL-2015, ENDF/B-VII.1, JEFF-3.2, JENDL-4.0u, CENDL-3.1 processed into fine-group-structure files, GEFY-5.2 and UKDD-16), as well as resolved and unresolved resonance range probability tables for self-shielding corrections and updated radiological hazard indices. The code has many novel features including: extension of the energy range up to 1 GeV; additional neutron physics including self-shielding effects, temperature dependence, thin and thick target yields; pathway analysis; and sensitivity and uncertainty quantification and propagation using full covariance data. The latest ENDF libraries such as TENDL encompass thousands of target isotopes. Nuclear data libraries for Fispact-II are prepared from these using processing codes PREPRO, NJOY and CALENDF. These data include resonance parameters, cross sections with covariances, probability tables in the resonance ranges, PKA spectra, kerma, dpa, gas and radionuclide production and energy-dependent fission yields, supplemented with all 27 decay types. All such data for the five most important incident particles are provided in evaluated data tables. The Fispact-II simulation software is described in detail in this paper, together with the nuclear data libraries. The Fispact-II system also includes several utility programs for code-use optimisation

  11. Inactive trials of transport systems: phase II

    International Nuclear Information System (INIS)

    Haberlin, M.M.; Hardy, A.R.; Kennedy, S.T.

    1986-11-01

    Progress made during 1984-85 is reviewed in four sections: the design and installation of a stainless steel working floor in the mock-up of a crate handling and size reduction facility; the detailed evaluation of a single air pad of the type used on commercial air-transporter; an experimental programme designed to examine the problems associated with the operation of a commercial air-transporter; the design, manufacture and commissioning trials of two powered conveyor units which when combined complete a remotely operated transfer system for transporting crated waste into and within the mock-up facility. (author)

  12. Magnetic Resonance Classification System of Cervical Intervertebral Disk Degeneration: Its Validity and Meaning.

    Science.gov (United States)

    Suzuki, Akinobu; Daubs, Michael D; Hayashi, Tetsuo; Ruangchainikom, Monchai; Xiong, Chenjie; Phan, Kevin; Scott, Trevor P; Wang, Jeffery C

    2017-06-01

    Retrospective analysis of kinetic magnetic resonance images (kMRIs). (1) To analyze the changes seen on MRI related to disk degeneration and to develop a new grading system for cervical disk degeneration. (2) To evaluate the reliability and validity of the grading system. Few have studied the relationship between changes seen on MRI with cervical disk degeneration and the chronological order of disk degeneration. A few grading systems for cervical disk degeneration have been reported; however, there have been problems related to subjectivity and lack of a clear, reliable algorithm. A total of 300 cervical intervertebral disks were graded for nucleus color, structure, disk bulge, and disk height. On the basis of the analysis, a new grading system consisting of 4 grades (grade 0-III) and algorithm were developed. Intraobserver and interobserver reliabilities were assessed. A total of 2802 intervertebral disks were then evaluated using the grading system to correlate disk degeneration grades with patient age and function and to evaluate the validity of the new system. On the basis of cross-table analysis, disk degeneration presents in the following order: (1) decrease and/or change of nucleus intensity; (2) loss of distinction between nucleus and annulus; (3) positive disk bulge; and (4) disk height decrease. The κ-coefficients for intraobserver and interobserver agreements were 0.96 and 0.90, respectively. Severe disk degeneration is most common at C5/C6 followed by C6/C7 and C4/C5, and total disk degeneration grade is correlated with age (R=0.467). There was a decrease of angular motion in grades I-III and an increase in translational motion and decrease of space available for the cord in grades II-III. We developed a new classification system of cervical disk degeneration based on analysis of the changes seen on MRI. Reliability tests indicated high reproducibility of this system, and further analysis confirmed its validity and clinical significance.

  13. System Size Resonance Associated with Canard Phenomenon in a Biological Cell System

    Science.gov (United States)

    Ma, Juan; Li, Hong-ying; Hou, Zhong-huai; Xin, Hou-wen

    2008-12-01

    The influence of internal noise on the calcium oscillations is studied. It is found that stochastic calcium oscillations occur when the internal noise is considered, while the corresponding deterministic dynamics only yields a steady state. Also, the performance of such oscillations shows two maxima with the variation of the system size, indicating the occurrence of system size resonance. This behavior is found to be intimately connected with the canard phenomenon. Interestingly, it is also found that one of the optimal system sizes matches well with the real cell size, and such a match is robust to the variation of the control parameters.

  14. Noise generation by ducted combustion systems. [resonant oscillations

    Science.gov (United States)

    Chiu, H. H.; Plett, E. G.; Summerfield, M.

    1973-01-01

    Analysis of the interaction between a zone of nonsteady combustion and its confining duct shows that resonant type oscillations occur with resulting noise intensities far greater than from corresponding unconfined flame zones. The blading action on the flow through the compressor and turbine of an engine generates discrete frequency noise which, it is found, is enhanced by the response of the combustion zone in between. Ducted combustor experiments verify the predicted resonant type noise, the amplitude and frequency of which are strongly influenced by the duct dimensions and end impedance. A convergent exit nozzle results in stronger internal resonant noise oscillations but also generates a higher jet velocity, with the attendant jet noise which exceeds noise from inside the duct at jet Mach numbers near unity.-

  15. Mark-II Data Acquisition and Trigger system

    International Nuclear Information System (INIS)

    Breidenbach, M.

    1984-06-01

    The Mark-II Data Acquisition and Trigger system requirements and general solution are described. The solution takes advantage of the synchronous crossing times and low event rates of an electron positron collider to permit a very highly multiplexed analog scheme to be effective. The system depends on a two level trigger to operate with acceptable dead time. The trigger, multiplexing, data reduction, calibration, and CAMAC systems are described

  16. Data systems in FFTF and EBR-II

    International Nuclear Information System (INIS)

    Warrick, R.P.; Ritter, W.M.

    1980-02-01

    This paper describes the Data System used to monitor operation and collect experimental data in FFTF. This data system has evolved since initial inception from a relatively simple, single computer system monitoring a relatively few (approx. 1000) instrument channels important for operation to one which has increased capability to support the long-range testing needs in FFTF. The system, while still relatively simple, now contains multiple computers which normally perform independent functions. The computers, however, provide backup processing for certain simple tasks. Operator interfacing is provided through CRT's. The output capabilities of the system are described. A description of the Data System in EBR-II is also included

  17. Photon transfer in a system of coupled superconducting microwave resonators

    Energy Technology Data Exchange (ETDEWEB)

    Muirhead, C. M., E-mail: c.m.muirhead@bham.ac.uk; Gunupudi, B.; Colclough, M. S. [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)

    2016-08-28

    A novel scheme is proposed for the study of energy transfer in a pair of coupled thin film superconducting microwave resonators. We show that the transfer could be achieved by modulating the kinetic inductance and that this has a number of advantages over earlier theoretical and experimental schemes, which use modulation of capacitance by vibrating nanobars or membranes. We show that the proposed scheme lends itself to the study of the classical analogues of Rabi and Landau-Zener-Stueckelberg oscillations and Landau-Zener transitions using experimentally achievable parameters. We consider a number of ways in which energy transfer (photon shuttle) between the two resonators could be achieved experimentally.

  18. Harmonic Resonance Damping with a Hybrid Compensation System in Power Systems with Dispersed Generation

    DEFF Research Database (Denmark)

    Chen, Zhe; Pedersen, John Kim; Blaabjerg, Frede

    2004-01-01

    A hybrid compensation system consisting of an active filter and a group of distributed passive filters has been studied previously. The passive filters are used for each distorting load or Dispersed Generation (DG) unit to remove major harmonics and provide reactive power compensation. The active...... filter is connected in parallel with the distributed passive filters and loads/DGs to correct the system unbalance and remove the remaining harmonic components. The effectiveness of the presented compensation system has also been demonstrated. This paper studies the performance of the hybrid compensation...... demonstrated that the harmonic resonance can be damped effectively. The hybrid filter system is an effective compensation system for dispersed generation systems. In the compensation system, the passive filters are mainly responsible for main harmonic and reactive power compensation of each individual load/ DG...

  19. Impedance-Based High Frequency Resonance Analysis of DFIG System in Weak Grids

    OpenAIRE

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    The impedance-based model of Doubly Fed Induction Generator (DFIG) systems, including the rotor part (Rotor Side Converter (RSC) and induction machine), and the grid part (Grid Side Converter (GSC) and its output filter), has been developed for analysis and mitigation of the Sub- Synchronous Resonance (SSR). However, the High Frequency Resonance (HFR) of DFIG systems due to the impedance interaction between DFIG system and parallel compensated weak network is often overlooked. This paper thus...

  20. Evolutionary Dynamics While Trapped in Resonance: A Keplerian Binary System Perturbed by Gravitational Radiation

    OpenAIRE

    Chicone, Carmen; Mashhoon, Bahram; Retzloff, David

    1996-01-01

    The method of averaging is used to investigate the phenomenon of capture into resonance for a model that describes a Keplerian binary system influenced by radiation damping and external normally incident periodic gravitational radiation. The dynamical evolution of the binary orbit while trapped in resonance is elucidated using the second order partially averaged system. This method provides a theoretical framework that can be used to explain the main evolutionary dynamics of a physical system...

  1. Sensory systems II senses other than vision

    CERN Document Server

    Wolfe, Jeremy M

    1988-01-01

    This series of books, "Readings from the Encyclopedia of Neuroscience." consists of collections of subject-clustered articles taken from the Encyclopedia of Neuroscience. The Encyclopedia of Neuroscience is a reference source and compendium of more than 700 articles written by world authorities and covering all of neuroscience. We define neuroscience broadly as including all those fields that have as a primary goal the under­ standing of how the brain and nervous system work to mediate/control behavior, including the mental behavior of humans. Those interested in specific aspects of the neurosciences, particular subject areas or specialties, can of course browse through the alphabetically arranged articles of the En­ cyclopedia or use its index to find the topics they wish to read. However. for those readers-students, specialists, or others-who will find it useful to have collections of subject-clustered articles from the Encyclopedia, we issue this series of "Readings" in paperback. Students in neuroscienc...

  2. Two Stochastic Resonances Induced by Two Different Multiplicative Telegraphic Noises for an Electric System

    International Nuclear Information System (INIS)

    Li Jinghui

    2008-01-01

    In this paper, an electric system with two dichotomous resistors is investigated. It is shown that this system can display two stochastic resonances, which are the amplitude of the periodic response as the functions of the two dichotomous resistors strengthes respectively. In the limits of Gaussian white noise and shot white noise (i.e., the two noises are both Gaussian white noise or shot white noise), no phenomena of resonance appear. By further study, we find that when the system is with three or more multiplicative telegraphic noises, there are three or more stochastic resonances

  3. Central nervous system abnormalities on midline facial defects with hypertelorism detected by magnetic resonance image and computed tomography

    International Nuclear Information System (INIS)

    Lopes, Vera Lucia Gil da Silva; Giffoni, Silvio David Araujo

    2006-01-01

    The aim of this study were to describe and to compare structural central nervous system (CNS) anomalies detected by magnetic resonance image (MRI) and computed tomography (CT) in individuals affected by midline facial defects with hypertelorism (MFDH) isolated or associated with multiple congenital anomalies (MCA). The investigation protocol included dysmorphological examination, skull and facial X-rays, brain CT and/or MRI. We studied 24 individuals, 12 of them had an isolated form (Group I) and the others, MCA with unknown etiology (Group II). There was no significant difference between Group I and II and the results are presented in set. In addition to the several CNS anomalies previously described, MRI (n=18) was useful for detection of neuronal migration errors. These data suggested that structural CNS anomalies and MFDH seem to have an intrinsic embryological relationship, which should be taken in account during the clinical follow-up. (author)

  4. The NASA F-15 Intelligent Flight Control Systems: Generation II

    Science.gov (United States)

    Buschbacher, Mark; Bosworth, John

    2006-01-01

    The Second Generation (Gen II) control system for the F-15 Intelligent Flight Control System (IFCS) program implements direct adaptive neural networks to demonstrate robust tolerance to faults and failures. The direct adaptive tracking controller integrates learning neural networks (NNs) with a dynamic inversion control law. The term direct adaptive is used because the error between the reference model and the aircraft response is being compensated or directly adapted to minimize error without regard to knowing the cause of the error. No parameter estimation is needed for this direct adaptive control system. In the Gen II design, the feedback errors are regulated with a proportional-plus-integral (PI) compensator. This basic compensator is augmented with an online NN that changes the system gains via an error-based adaptation law to improve aircraft performance at all times, including normal flight, system failures, mispredicted behavior, or changes in behavior resulting from damage.

  5. Evaluation of orthognathic surgery on articular disc position and temporomandibular joint symptoms in skeletal class II patients: A Magnetic Resonance Imaging study.

    Science.gov (United States)

    Firoozei, Gholamreza; Shahnaseri, Shirin; Momeni, Hasan; Soltani, Parisa

    2017-08-01

    The purpose of orthognathic surgery is to correct facial deformity and dental malocclusion and to obtain normal orofacial function. However, there are controversies of whether orthognathic surgery might have any negative influence on temporomandibular (TM) joint. The purpose of this study was to evaluate the influence of orthognathic surgery on articular disc position and temporomandibular joint symptoms of skeletal CI II patients by means of magnetic resonance imaging. For this purpose, fifteen patients with skeletal CI II malocclusion, aged 19-32 years (mean 23 years), 10 women and 5 men, from the Isfahan Department of Oral and Maxillofacial Surgery were studied. All received LeFort I and bilateral sagittal split osteotomy (BSSO) osteotomies and all patients received pre- and post-surgical orthodontic treatment. Magnetic resonance imaging was performed 1 day preoperatively and 3 month postoperatively. Descriptive statistics and Wilcoxon and Mc-Nemar tests were used for statistical analysis. P magnetic resonance imaging, temporomandibular disc.

  6. Kilowatt isotope power system phase II plan. Volume II: flight System Conceptual Design (FSCD)

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-01

    The Kilowatt Isotope Power System (KIPS) Flight System Conceptual Design (FSCD) is described. Included are a background, a description of the flight system conceptual design, configuration of components, flight system performance, Ground Demonstration System test results, and advanced development tests.

  7. Resonant behaviour of MHD waves on magnetic flux tubes. I - Connection formulae at the resonant surfaces. II - Absorption of sound waves by sunspots

    Science.gov (United States)

    Sakurai, Takashi; Goossens, Marcel; Hollweg, Joseph V.

    1991-01-01

    The present method of addressing the resonance problems that emerge in such MHD phenomena as the resonant absorption of waves at the Alfven resonance point avoids solving the fourth-order differential equation of dissipative MHD by recourse to connection formulae across the dissipation layer. In the second part of this investigation, the absorption of solar 5-min oscillations by sunspots is interpreted as the resonant absorption of sounds by a magnetic cylinder. The absorption coefficient is interpreted (1) analytically, under certain simplifying assumptions, and numerically, under more general conditions. The observed absorption coefficient magnitude is explained over suitable parameter ranges.

  8. Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    Science.gov (United States)

    Salvati, Roberto; Hitti, Eric; Bellanger, Jean-Jacques; Saint-Jalmes, Hervé; Gambarota, Giulio

    2016-06-01

    Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. Various numerical phantoms with a given fat fraction, T2* and field map were designed. The k-space of numerical phantoms was converted into RF signals to generate virtual phantoms. MRI experiments were performed at 4.7T using a multi-gradient-echo sequence on virtual and physical phantoms. The data acquisition of virtual and physical phantoms was simultaneous. Decomposition of the water and fat signals was performed using a complex-based water-fat separation algorithm. Overall, a good agreement was observed between the fat fraction, T2* and phase map values of the virtual and numerical phantoms. In particular, fat fractions of 10.5±0.1 (vs 10% of the numerical phantom), 20.3±0.1 (vs 20%) and 30.4±0.1 (vs 30%) were obtained in virtual phantoms. The ViP MRI method allows for generating imaging phantoms that i) mimic water-fat systems and ii) can be analyzed with water-fat separation algorithms based on complex data. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Integrated Monitoring System II (IMS-II). User's manual

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, M.H.

    1985-08-01

    The IMS-II was designed to monitor up to four unattended areas containing assets of safeguards interest through the use of video equipment and motion detectors. One module of the system equipment is the Inspector Display Module (IDM), which interacts with the Data Collection Module (DCM) to initialize the system and retrieve data from the DCM. This document is intended to guide an inspector through the various functions of the IDM for the purpose of initializing and retrieving information once the system is operational. 5 figs.

  10. Ruthenium (II)-bipyridyl with extended -system: Improved thermo ...

    Indian Academy of Sciences (India)

    Ruthenium(II)- bipyridyl with extended -system: Improved thermo-stable sensitizer for efficient and long-term durable dye sensitized solar cells ... The Density Functional Theory (DFT) and Time-Dependent DFT excited state calculations of the new sensitizer show that the first three HOMOs have t2g character with sizeable ...

  11. Advanced Weapon System (AWS) Sensor Prediction Techniques Study. Volume II

    Science.gov (United States)

    1981-09-01

    REPRESENTATION OF MOTION BY COMPUTER USING A THREE-DIMENSIONAL MODELO S CARNEGIE-MELLON UNIVP PITTSBURGH, COMPUTER SCIENCE THESIS PR)PJSAL A RAMER, U. E. (1973...Port_ ii SYSTEM CONTACTS Bill Lalond Norpak VOP PakenhaM (Ottawa) 1-613-624-5507, 5570 IMAGE MEMORY nw basic confi urations nevort 512 x 512 x 4 for

  12. Simulation of advanced ultrasound systems using Field II

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2004-01-01

    The background and basic features of the Field II simulation program are described. It can simulate any linear ultrasound system, which can use single or multi-element transducers. Any kind of apodization, focusing, and excitation can be used. The basic theory behind the program's use of spatial ...

  13. Open Architecture Standards and Information Systems (OASIS II ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Open Architecture Standards and Information Systems (OASIS II) - Developing Capacity, Sharing Knowledge and Good Principles Across eHealth in Africa. Health care across much of the African continent is hampered by meager resources and a growing burden of disease, with HIV/AIDS, tuberculosis (TB) and malaria ...

  14. The Electronic Structure of Mn in Oxides, Coordination Complexes, and the Oxygen-Evolving Complex of Photosystem II Studied by Resonant Inelastic X-ray Scattering

    Science.gov (United States)

    Yano, Junko; Visser, Hendrik; Robblee, John H.; Gu, Weiwei; de Groot, Frank M. F.; Christou, George; Pecoraro, Vincent L.

    2014-01-01

    Resonant inelastic X-ray scattering (RIXS) was used to collect Mn K pre-edge spectra and to study the electronic structure in oxides, molecular coordination complexes, as well as the S1 and S2 states of the oxygen-evolving complex (OEC) of photosystem II (PS II). The RIXS data yield two-dimensional plots that can be interpreted along the incident (absorption) energy or the energy transfer axis. The second energy dimension separates the pre-edge (predominantly 1s to 3d transitions) from the main K-edge, and a detailed analysis is thus possible. The 1s2p RIXS final-state electron configuration along the energy transfer axis is identical to conventional L-edge absorption spectroscopy, and the RIXS spectra are therefore sensitive to the Mn spin state. This new technique thus yields information on the electronic structure that is not accessible in conventional K-edge absorption spectroscopy. The line splittings can be understood within a ligand field multiplet model, i.e., (3d,3d) and (2p,3d) two-electron interactions are crucial to describe the spectral shapes in all systems. We propose to explain the shift of the K pre-edge absorption energy upon Mn oxidation in terms of the effective number of 3d electrons (fractional 3d orbital population). The spectral changes in the Mn 1s2p3/2 RIXS spectra between the PS II S1 and S2 states are small compared to that of the oxides and two of the coordination complexes (MnIII(acac)3 and MnIV(sal)2(bipy)). We conclude that the electron in the step from S1 to S2 is transferred from a strongly delocalized orbital. PMID:15303869

  15. Backbone and sterospecific methyl side chain resonance assignments of the homodimeric zinc sensor AdcR (32 kDa) in the apo- and Zn(II)-bound states.

    Science.gov (United States)

    Guerra, Alfredo J; Giedroc, David P

    2014-04-01

    Streptococcus pneumoniae adhesin competence repressor (AdcR) is a Zn(II)-dependent 32 kDa homodimer that controls the transcription of a zinc-specific ABC uptake system (AdcABC), three pneumococcal histidine triad proteins (PhtA, PhtD and PhtE), and an AdcA homolog AdcAII. AdcR is the first metal-dependent member of the MarR family of prokaryotic transcriptional repressors. Two-dimensional NMR studies reveal large changes in the spectrum upon Zn(II) binding. Near complete backbone and stereospecific methyl group resonance assignments for apo- and Zn(II)-AdcR are presented here.

  16. [Magnetic resonance angiography in the diagnosis of cerebrovascular diseases in systemic lupus erythematosus].

    Science.gov (United States)

    Pizova, N V; Spirin, N N; Maksimov, G A; Bakhtin, A L

    2004-01-01

    Fifty one patients with systemic lupus erythematous were examined using magnetic resonance angiography (MRA) to determine cerebral hemodynamic features. A comprehensive study revealed different cerebral circulatory changes in this abnormality.

  17. Status of NSLS-II Storage Ring Vacuum Systems

    Energy Technology Data Exchange (ETDEWEB)

    Doom,L.; Hseuh,H.; Ferreira, M.; Longo, C.; Ravindranath, V.; Settepani, P.; Sharma, S.; Wilson, K.

    2009-05-04

    National Synchrotron Light Source II (NSLS-II), being constructed at Brookhaven National Laboratory, is a 3-GeV, high-flux and high- brightness synchrotron radiation facility with a nominal current of 500 mA. The storage ring vacuum system will have extruded aluminium chambers with ante-chamber for photon fans and distributed NEG strip pumping. Discrete photon absorbers will be used to intercept the un-used bending magnet radiation. In-situ bakeout will be implemented to achieve fast conditioning during initial commissioning and after interventions.

  18. PEP-II vacuum system pressure profile modeling using EXCEL

    International Nuclear Information System (INIS)

    Nordby, M.; Perkins, C.

    1994-06-01

    A generic, adaptable Microsoft EXCEL program to simulate molecular flow in beam line vacuum systems is introduced. Modeling using finite-element approximation of the governing differential equation is discussed, as well as error estimation and program capabilities. The ease of use and flexibility of the spreadsheet-based program is demonstrated. PEP-II vacuum system models are reviewed and compared with analytical models

  19. RF system design for the PEP-II B Factory

    International Nuclear Information System (INIS)

    Schwarz, H.; Rimmer, R.

    1994-06-01

    The paper presents an overview of the design of the RF system for the PEP-II B Factory. An RF station consists of either two or four single-cell cavities driven by a 1.2 MW klystron through a waveguide distribution network. A variety of feedback loops stabilize the RF and its interaction with the beam. System parameters and all the relevant parameters of klystron and cavities are given

  20. Possibility of narrow resonances of the omega anti omega-system

    International Nuclear Information System (INIS)

    Duerr, H.P.

    1975-01-01

    The possibility of resonances of the Ω anti Ω-system is discussed on the basis of the medium and long range meson exchange forces. The total and partial widths of these resonances are estimated by using well known formulas of nuclear physics. It is demonstrated that analogously the phi- and rho-mesons may be interpreted as p-states of the K anti K- and π π-system, respectively. There appears, however, only a slim chance to interpret the new narrow resonances psi (3100) and psi (3700) as 7 d 1 - and 7 g 1 -Ω anti Ω configurations

  1. Structure and resonances of the e+–He(1s2s 3Se) system

    International Nuclear Information System (INIS)

    Ren Zhenzhong; Han Huili; Shi Tingyun; Mitroy, J

    2012-01-01

    We have studied the geometry and resonances of the e + He( 3 S e ) system in the framework of hyperspherical coordinates. A model potential proposed by us is used to describe the interaction between the out electron with the He + ionic core. The calculated binding energy and expectation distance of the system are in agreement with other calculations. In addition, two resonances below the e + –He(1s3s 3 S e ) threshold and one resonance below the Ps(n=2)–He + threshold are identified. (paper)

  2. Ferromagnetic resonance in gigahertz magneto-impedance of multilayer systems

    International Nuclear Information System (INIS)

    Cos, D. de; Garcia-Arribas, A.; Barandiaran, J.M.

    2006-01-01

    The effect of ferromagnetic resonance (FMR) on magneto-impedance (MI) of multilayer thin films is investigated. We present impedance measurements of an insulated multilayer film as a function of the applied magnetic field both in the plane of the sample and perpendicular to it, for frequencies from 300 kHz to 3 GHz. These measurements have been made using RF techniques, and the data have been treated using high-frequency models in order to minimize the contribution to the impedance of the test fixture. The results confirm that the FMR dominates the MI behavior at high frequency, allowing to reach higher MI ratios than those achieved at the quasistatic regime. However, the broad resonance lines cause a considerable drop of the sensitivity of the curves, and therefore the optimum operation frequency of GMI devices lays in the sub-GHz range

  3. Heat dissipation and information flow for delayed bistable Langevin systems near coherence resonance.

    Science.gov (United States)

    Xiao, Tiejun

    2016-11-01

    In this paper, stochastic thermodynamics of delayed bistable Langevin systems near coherence resonance is discussed. We calculate the heat dissipation rate and the information flow of a delayed bistable Langevin system under various noise intensities. Both the heat dissipation rate and the information flow are found to be bell-shaped functions of the noise intensity, which implies that coherence resonance manifests itself in the thermodynamic properties.

  4. Sub-micron surface plasmon resonance sensor systems

    Science.gov (United States)

    Glazier, James A. (Inventor); Amarie, Dragos (Inventor)

    2013-01-01

    Wearable or implantable devices combining microfluidic control of sample and reagent flow and micro-cavity surface plasmon resonance sensors functionalized with surface treatments or coatings capable of specifically binding to target analytes, ligands, or molecules in a bodily fluid are provided. The devices can be used to determine the presence and concentration of target analytes in the bodily fluids and thereby help diagnose, monitor or detect changes in disease conditions.

  5. Battle Staff Training System II: Computer-Based Instruction Supporting the Force XXI Training Program

    National Research Council Canada - National Science Library

    Wampler, Richard

    1998-01-01

    This report documents the methodology and lessons learned in the development of the Innovative Tools and Techniques for Brigade and Below Staff Training II - Battle Staff Training System II (ITTBBST-BSTS II...

  6. Automated System for Control of the Vacuum Diagnostic System for the TJ-II

    International Nuclear Information System (INIS)

    Lopez Sanchez, A.; Montoro Peinado, A.; Encabo Fernandez, J.; Gama de la Serrano, J.; Sanchez Sarabia, E.

    1999-12-01

    This report describes the monitoring and remote control systems belonging to the high vacuum systems of the TJ-II diagnostics. These systems are part of each diagnostic and their control has been integrated into the automata that carries out this task. All the controllers are connected through a Profibus network, so as to interchange data between themselves as well as between the general system of TJ-II. (Author)

  7. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    Science.gov (United States)

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Electronic paramagnetic resonance in the Mn In X (X:Te,S) diluted magnetic semiconductor system

    International Nuclear Information System (INIS)

    Vincent, Bernardo; Betancourt, Luis; Sagredo, Vicente; Alcala, Rafael

    1996-01-01

    Semiconductor compounds wit the II-III-VI stoichiometry are very interesting materials since they present very good semiconducting characteristics and, along with strong magnetic properties, these II Mn In VI compounds have a great potential as opt and magneto-electronic devices. Among the possible magnetic properties of the materials is the presence of the spin-glass phase. Electron paramagnetic resonance is one of the techniques used to confirm this phase. The chosen crystals were chosen by chemical vapor transport. The absorption lines of these two families with 0.1 x 1 were all Lorentzian in shape and centred at g=2. A large broadening of the resonance line width was observed when lowering the temperature to below 80 K. This behaviour was fitted to the known existing models, and good values of the calculated parameters were obtained (author)

  9. Automated detection of focal cortical dysplasia type II with surface-based magnetic resonance imaging postprocessing and machine learning.

    Science.gov (United States)

    Jin, Bo; Krishnan, Balu; Adler, Sophie; Wagstyl, Konrad; Hu, Wenhan; Jones, Stephen; Najm, Imad; Alexopoulos, Andreas; Zhang, Kai; Zhang, Jianguo; Ding, Meiping; Wang, Shuang; Wang, Zhong Irene

    2018-04-10

    Focal cortical dysplasia (FCD) is a major pathology in patients undergoing surgical resection to treat pharmacoresistant epilepsy. Magnetic resonance imaging (MRI) postprocessing methods may provide essential help for detection of FCD. In this study, we utilized surface-based MRI morphometry and machine learning for automated lesion detection in a mixed cohort of patients with FCD type II from 3 different epilepsy centers. Sixty-one patients with pharmacoresistant epilepsy and histologically proven FCD type II were included in the study. The patients had been evaluated at 3 different epilepsy centers using 3 different MRI scanners. T1-volumetric sequence was used for postprocessing. A normal database was constructed with 120 healthy controls. We also included 35 healthy test controls and 15 disease test controls with histologically confirmed hippocampal sclerosis to assess specificity. Features were calculated and incorporated into a nonlinear neural network classifier, which was trained to identify lesional cluster. We optimized the threshold of the output probability map from the classifier by performing receiver operating characteristic (ROC) analyses. Success of detection was defined by overlap between the final cluster and the manual labeling. Performance was evaluated using k-fold cross-validation. The threshold of 0.9 showed optimal sensitivity of 73.7% and specificity of 90.0%. The area under the curve for the ROC analysis was 0.75, which suggests a discriminative classifier. Sensitivity and specificity were not significantly different for patients from different centers, suggesting robustness of performance. Correct detection rate was significantly lower in patients with initially normal MRI than patients with unequivocally positive MRI. Subgroup analysis showed the size of the training group and normal control database impacted classifier performance. Automated surface-based MRI morphometry equipped with machine learning showed robust performance across

  10. Neuroprotective Effects and Mechanisms of Curcumin–Cu(II and –Zn(II Complexes Systems and Their Pharmacological Implications

    Directory of Open Access Journals (Sweden)

    Fa-Shun Yan

    2017-12-01

    Full Text Available Alzheimer’s disease (AD is the main form of dementia and has a steadily increasing prevalence. As both oxidative stress and metal homeostasis are involved in the pathogenesis of AD, it would be interesting to develop a dual function agent, targeting the two factors. Curcumin, a natural compound isolated from the rhizome of Curcuma longa, is an antioxidant and can also chelate metal ions. Whether the complexes of curcumin with metal ions possess neuroprotective effects has not been evaluated. Therefore, the present study was designed to investigate the protective effects of the complexes of curcumin with Cu(II or Zn(II on hydrogen peroxide (H2O2-induced injury and the underlying molecular mechanisms. The use of rat pheochromocytoma (PC12 cells, a widely used neuronal cell model system, was adopted. It was revealed that curcumin–Cu(II complexes systems possessed enhanced O2·–-scavenging activities compared to unchelated curcumin. In comparison with unchelated curcumin, the protective effects of curcumin–Cu(II complexes systems were stronger than curcumin–Zn(II system. Curcumin–Cu(II or –Zn(II complexes systems significantly enhanced the superoxide dismutase, catalase, and glutathione peroxidase activities and attenuated the increase of malondialdehyde levels and caspase-3 and caspase-9 activities, in a dose-dependent manner. The curcumin–Cu(II complex system with a 2:1 ratio exhibited the most significant effect. Further mechanistic study demonstrated that curcumin–Cu(II or –Zn(II complexes systems inhibited cell apoptosis via downregulating the nuclear factor κB (NF-κB pathway and upregulating Bcl-2/Bax pathway. In summary, the present study found that curcumin–Cu(II or –Zn(II complexes systems, especially the former, possess significant neuroprotective effects, which indicates the potential advantage of curcumin as a promising agent against AD and deserves further study.

  11. Effects of time delay on stochastic resonance of the stock prices in financial system

    International Nuclear Information System (INIS)

    Li, Jiang-Cheng; Li, Chun; Mei, Dong-Cheng

    2014-01-01

    The effect of time delay on stochastic resonance of the stock prices in finance system was investigated. The time delay is introduced into the Heston model driven by the extrinsic and intrinsic periodic information for stock price. The signal power amplification (SPA) was calculated by numerical simulation. The results indicate that an optimal critical value of delay time maximally enhances the reverse-resonance in the behaviors of SPA as a function of long-run variance of volatility or cross correlation coefficient between noises for both cases of intrinsic and extrinsic periodic information. Moreover, in both cases, being a critical value in the delay time, when the delay time takes value below the critical value, reverse-resonance increases with the delay time increasing, however, when the delay time takes value above the critical value, the reverse-resonance decrease with the delay time increasing. - Highlights: • The effects of delay time on stochastic resonance of the stock prices was investigated. • There is an optimal critical value of delay time maximally enhances the reverse-resonance • The reverse-resonance increases with the delay time increasing as the delay time takes value below the critical value • The reverse-resonance decrease with the delay time increasing as the delay time takes value above the critical value

  12. Effects of time delay on stochastic resonance of the stock prices in financial system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jiang-Cheng [Department of Physics, Yunnan University, Kunming, 650091 (China); Li, Chun [Department of Computer Science, Puer Teachers' College, Puer 665000 (China); Mei, Dong-Cheng, E-mail: meidch@ynu.edu.cn [Department of Physics, Yunnan University, Kunming, 650091 (China)

    2014-06-13

    The effect of time delay on stochastic resonance of the stock prices in finance system was investigated. The time delay is introduced into the Heston model driven by the extrinsic and intrinsic periodic information for stock price. The signal power amplification (SPA) was calculated by numerical simulation. The results indicate that an optimal critical value of delay time maximally enhances the reverse-resonance in the behaviors of SPA as a function of long-run variance of volatility or cross correlation coefficient between noises for both cases of intrinsic and extrinsic periodic information. Moreover, in both cases, being a critical value in the delay time, when the delay time takes value below the critical value, reverse-resonance increases with the delay time increasing, however, when the delay time takes value above the critical value, the reverse-resonance decrease with the delay time increasing. - Highlights: • The effects of delay time on stochastic resonance of the stock prices was investigated. • There is an optimal critical value of delay time maximally enhances the reverse-resonance • The reverse-resonance increases with the delay time increasing as the delay time takes value below the critical value • The reverse-resonance decrease with the delay time increasing as the delay time takes value above the critical value.

  13. The simulation library of the Belle II software system

    Science.gov (United States)

    Kim, D. Y.; Ritter, M.; Bilka, T.; Bobrov, A.; Casarosa, G.; Chilikin, K.; Ferber, T.; Godang, R.; Jaegle, I.; Kandra, J.; Kodys, P.; Kuhr, T.; Kvasnicka, P.; Nakayama, H.; Piilonen, L.; Pulvermacher, C.; Santelj, L.; Schwenker, B.; Sibidanov, A.; Soloviev, Y.; Starič, M.; Uglov, T.

    2017-10-01

    SuperKEKB, the next generation B factory, has been constructed in Japan as an upgrade of KEKB. This brand new e+ e- collider is expected to deliver a very large data set for the Belle II experiment, which will be 50 times larger than the previous Belle sample. Both the triggered physics event rate and the background event rate will be increased by at least 10 times than the previous ones, and will create a challenging data taking environment for the Belle II detector. The software system of the Belle II experiment is designed to execute this ambitious plan. A full detector simulation library, which is a part of the Belle II software system, is created based on Geant4 and has been tested thoroughly. Recently the library has been upgraded with Geant4 version 10.1. The library is behaving as expected and it is utilized actively in producing Monte Carlo data sets for various studies. In this paper, we will explain the structure of the simulation library and the various interfaces to other packages including geometry and beam background simulation.

  14. An electron paramagnetic resonance study of the behaviour of copper (II) in ageing catechin-based model wines

    International Nuclear Information System (INIS)

    Mitri, M.; Scollary, G.R.; Troup, G.J.; Hutton, D.R.; Hunter, C.A.; Hewitt, D.G.

    1996-01-01

    This poster reports an electron paramagnetic resonance (EPR) study of copper in a model white wine. The model consists of a saturated 12% ethanol solution of potassium hydrogen tartrate solution (the 'wine base') containing copper and catechin as the oxidizable substrate. Ascorbic acid, as a supposed anti-oxidant, was added to some solutions. A Varian E-12 EPR spectrometer (∼9.1 GHz frequency) with quartz sample tubes was used and spectra were recorded at liquid nitrogen temperature to avoid polar water losses. Solutions were examined on four successive days whilst kept at room temperature and subsequently every third day when stored at 45 degree C. Variations in signal intensity, linewidth and form will be shown and the changes related to the degree of browning, as measured by visible absorption spectroscopy at 440 nm. The ESP spectra of the brown deposits reveal that the copper (II) ion is in a low symmetry site and a well defined free radical signal was also observed. No free radical signal was found in solutions containing copper and catechin, indicating that a high degree of polymerization of the oxidized catechin is required to stabilize the free radical species

  15. High resolution spectroscopy at FRM II: neutron resonance spin echo, back scattering and time-of-flight instrumentation

    International Nuclear Information System (INIS)

    Petry, W.

    2001-01-01

    The new German neutron source FRM II is equipped with a D 2 cold source placed in the maximum of the thermal flux in the D 2 O moderator. This cold source feeds six large neutron guides. Among others a neutron resonance spin echo (NRSE), a back scattering (BS) and a time-of-flight (TOF) spectrometer will be placed at end positions of theses guides. By detailed Monte-Carlo simulations each of the instruments is optimized for highest intensity without scarifying energy resolution. A polarized neutron guide in combination with a non magnetic wave-length selector provides high flux at the sample position of the NRSE instrument with typical spin-echo times of 30 ns at all accessible scattering angles. The BS instrument uses phase-space transformation to compress a large spread of incoming wave length to an intense monoenergetic but angular disperse beam at the sample. An intensity gain by a factor of four has been calculated without losses in energy resolution of <1 μeV (fwhm) when compared to conventional BS. The TOF spectrometer suppresses background from fast neutrons by a S-curved super-mirror guide and focusses a large incoming neutron beam onto a small sample volume, thereby increasing the flux at the sample position by a factor 3.2. Energy resolution of typical 30 μeV (fwhm) at a wave length of λ=5 A is achieved by extremely fast turning chopper discs made of carbon fiber. (author)

  16. Study on frequency characteristics of wireless power transmission system based on magnetic coupling resonance

    Science.gov (United States)

    Liang, L. H.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Yue, Z. K.; Cui, S.

    2017-11-01

    In order to study the frequency characteristics of the wireless energy transmission system based on the magnetic coupling resonance, a circuit model based on the magnetic coupling resonant wireless energy transmission system is established. The influence of the load on the frequency characteristics of the wireless power transmission system is analysed. The circuit coupling theory is used to derive the minimum load required to suppress frequency splitting. Simulation and experimental results verify that when the load size is lower than a certain value, the system will appear frequency splitting, increasing the load size can effectively suppress the frequency splitting phenomenon. The power regulation scheme of the wireless charging system based on magnetic coupling resonance is given. This study provides a theoretical basis for load selection and power regulation of wireless power transmission systems.

  17. Impedance-Based High Frequency Resonance Analysis of DFIG System in Weak Grids

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    The impedance-based model of Doubly Fed Induction Generator (DFIG) systems, including the rotor part (Rotor Side Converter (RSC) and induction machine), and the grid part (Grid Side Converter (GSC) and its output filter), has been developed for analysis and mitigation of the Sub- Synchronous...... Resonance (SSR). However, the High Frequency Resonance (HFR) of DFIG systems due to the impedance interaction between DFIG system and parallel compensated weak network is often overlooked. This paper thus investigates the impedance characteristics of DFIG systems for the analysis of HFR. The influences...... of the rotor speed variation, the machine mutual inductance and the digital control delay are evaluated. Two resonances phenomena are revealed, i.e., 1) the series HFR between the DFIG system and weak power grid; 2) the parallel HFR between the rotor part and the grid part of DFIG system. The impedance...

  18. Acoustic resonance scattering by a system of concentrically multilayered shells: the inherent background and resonance coefficients

    CERN Document Server

    Choi, M S; Lee, S H

    1999-01-01

    The inherent background coefficients that exactly describe the background amplitudes in the scattered field have been presented for the scattering of plane acoustic waves by a system of concentrically multilayered solid and/or fluid shells submerged in a fluid. The coefficients have been obtained by replacing the mechanical surface admittance function with the zero-frequency limit of the admittance function for the analogous fluid system, where the shear wave speeds in the solid layers are set to zero. By taking advantage of the concept of incoming and outgoing waves, we find the surface admittance function for the fluid system in such a form that the analytical generalization for any number of layers and the physical interpretation are very easy. The background coefficients obtained are independent of the bulk wave speeds in the system: they depend on the mass densities and the thickness of the shells. With increasing frequency, the inherent background undergoes a transition from the soft to the rigid backgr...

  19. Magnetism in heterogeneous thin film systems: Resonant X-ray scattering studies

    International Nuclear Information System (INIS)

    Kortright, J.B.; Jiang, J.S.; Bader, S.D.; Hellwig, O.; Marguiles, D.T.; Fullerton, E.E.

    2002-01-01

    Magnetic and chemical heterogeneity are common in a broad range of magnetic thin film systems. Emerging resonant soft x-ray scattering techniques are well suited to resolve such heterogeneity at relevant length scales. Resonant x-ray magneto-optical Kerr effect measurements laterally average over heterogeneity but can provide depth resolution in different ways, as illustrated in measurements resolving reversible and irreversible changes in different layers of exchange-spring heterostructures. Resonant small-angle scattering measures in-plane heterogeneity and can resolve magnetic and chemical scattering sources in different ways, as illustrated in measurements of granular alloy recording media

  20. Magnetic resonance imaging of the central nervous system. Comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Kajima, Toshio; Kagawa, Yoshihiro; Katsuta, Shizutomo.

    1987-06-01

    Magnetic resonance imaging (MRI) and X-ray computed tomography (X-ray CT) have been performed in 169 consecutive patients with central nervous system diseases. The findings from the two methods were compared for the capacity to defect lesions. Magnetic resonance imaging was more sensitive than or equivalent to X-ray CT in detecting lesions - especially detecting. Arnold-Chiari malformation, syringomyelia, spinal cord injury, and pituitary adenoma - in 158 patients (94 %). In six patients (10 %), lesion detection was possible only by MRI. Magnetic resonance imaging was inferior to X-ray CT in 11 patients (7 %) in detecting calcified lesions, meningioma, and cavernous hemangioma. (Namekawa, K.).

  1. Synchrobetatron resonances

    International Nuclear Information System (INIS)

    1977-03-01

    At the 1975 Particle Accelerator Conference it was reported that a class of resonances were observed in SPEAR II that had not appeared before in SPEAR I. While the existence of sideband resonances of the main betatron oscillation frequencies has been previously observed and analyzed, the resonances observed in SPEAR do not appear to be of the same variety. Experiments were performed at SPEAR to identify the mechanism believed to be the most likely explanation. Some of the current experimental knowledge and theoretical views on the source of these resonances are presented

  2. UO2-PuO2 critical experiments based on a coupled NJOY/AMPX-II/HAMMER-TECHNION system

    International Nuclear Information System (INIS)

    Fernandes, M.A.R.

    1990-01-01

    The performance of the HAMMER-TECHNION system in the criticality analysis of mixed oxide (UO sub(2)-PuO sub(2)) fuel pins clad with Zircaloy-2 and having light water as moderator was analyzed in this work. The basic nuclear data libraries for the HAMMER-TECHNION have been generated by processing the ENDF/B-IV and JENDL-2 nuclear data files with the NJOY system. The question of the effect of Plutonium resonances close to the thermal region on the average thermal parameters was addressed by creating a special version of the HAMMER-TECHNION system with the thermal energy cut-off at 1.855 eV. The final system effective multiplication factor was calculated with the CITATION code by using the homogeneized four-group cross sections generated by the HAMMER-TECHNION system. Results are shown for the original HAMMER-TECHNION thermal cut-off and for the one at 1.855 eV. Besides that, for some selected critical systems, the effect of the resonance interference among the resonances of the Uranium and Plutonium isotopes was addressed by using the ROLAIDS module of the AMPX-II system. The effect of the thermal energy cut-off on the integral parameters of the critical systems was not found to be of extreme importance. (author)

  3. Integrated microwave resonant device for dielectric analysis of microfluidic systems

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, D J; Porch, A; Barrow, D A [School of Engineering, Cardiff University, Cardiff CF24 3AA (United Kingdom); Allender, C J, E-mail: rowedj@cf.ac.uk [Welsh School of Pharmacy, Cardiff University, Cardiff CF24 3NB (United Kingdom)

    2011-08-12

    Herein we present a device for performing non-contact dielectric spectroscopy upon liquids in a microfluidic environment. The device is comprised of a compression-sealed polytetrafluoroethylene (PTFE) chip with an embedded coaxial resonator, which is overmoded for dielectric measurements at six discrete frequencies between 1 and 8 GHz. A novel capacitive coupling structure allows transmission measurements to be taken from one end of the resonator, and an optimised microchannel design maximises sensitivity and repeatability. The use of a PTFE substrate and a non-contact measurement gives excellent chemical and biological compatibility. A simple 'fingerprint' method for identifying solvents is demonstrated, whereby a sample is characterised by air-referenced changes in complex frequency. Complex permittivity values are also obtained via a perturbation theory-based inversion. A combination of experimental and simulated results is used to characterise the device behaviour, limits of operation and measurement uncertainty. The high stability of temporal measurements, coupled with the robustness of the design, make this device ideal for analytical chemistry and industrial process control.

  4. Study on A Control Method of PAPF for Resonance Damping and Harmonics Compensation in Power System

    DEFF Research Database (Denmark)

    Zhou, Fang; Wu, Longhui; Chen, Zhe

    2009-01-01

    In power system, capacitors are widely used to compensate reactive power, which generally cause resonance problems in harmonic distorted network. In this paper, A method of using a parallel active power filter (PAPF) to damp the resonances is proposed. The proposed method is compound with traditi......In power system, capacitors are widely used to compensate reactive power, which generally cause resonance problems in harmonic distorted network. In this paper, A method of using a parallel active power filter (PAPF) to damp the resonances is proposed. The proposed method is compound...... with traditional method, it shows that whether the capacitor current is included in the detecting current of PAPF or not. Also the PAPF with proposed method has strong ability in harmonic compensation. Finally, the experiment results are presented to verify the analysis....

  5. LCLS-II high power RF system overview and progress

    Energy Technology Data Exchange (ETDEWEB)

    Yeremian, Anahid Dian

    2015-10-07

    A second X-ray free electron laser facility, LCLS-II, will be constructed at SLAC. LCLS-II is based on a 1.3 GHz, 4 GeV, continuous-wave (CW) superconducting linear accelerator, to be installed in the first kilometer of the SLAC tunnel. Multiple types of high power RF (HPRF) sources will be used to power different systems on LCLS-II. The main 1.3 GHz linac will be powered by 280 1.3 GHz, 3.8 kW solid state amplifier (SSA) sources. The normal conducting buncher in the injector will use four more SSAs identical to the linac SSAs but run at 2 kW. Two 185.7 MHz, 60 kW sources will power the photocathode dual-feed RF gun. A third harmonic linac section, included for linearizing the bunch energy spread before the first bunch compressor, will require sixteen 3.9 GHz sources at about 1 kW CW. A description and an update on all the HPRF sources of LCLS-II and their implementation is the subject of this paper.

  6. Magnetic depth profiling of an exchange bias system: X-ray resonant magnetic reflectivity of FeMn/Co

    Energy Technology Data Exchange (ETDEWEB)

    Brueck, Sebastian; Ferreras-Paz, Valeriano; Goering, Eberhard; Schuetz, Gisela [Max-Planck-Institut fuer Metallforschung, Heisenbergstrasse 3, D-70569 Stuttgart (Germany)

    2007-07-01

    X-ray resonant magnetic reflectivity (XRMR) extends reflectivity by the X-ray magnetic circular dichroism as additional contrast thus providing element selective magnetic depth information. This makes it a perfect tool to investigate magnetic coupling effects in multi-layered systems. Such systems are for example ferromagnet-antiferromagnet bilayers which can show an exchange coupling between the two layers, the so called exchange bias effect. We present results on Co/FeMn bilayers which have been investigated by XRMR at the BESSY II synchrotron, Berlin. The bilayers were prepared by molecular beam epitaxy on a Cu(100) single crystal which ensures epitaxial growth of both FeMn (in the antiferromagnetic phase) and Co. The magnetic depth profile for room temperature and for 120 K is investigated with respect to changes of the exchange coupling.

  7. Ion-imprinted nanoparticles for the concurrent estimation of Pb(II) and Cu(II) ions over a two channel surface plasmon resonance-based fiber optic platform

    Science.gov (United States)

    Shrivastav, Anand Mohan; Gupta, Banshi D.

    2018-01-01

    We report the design, fabrication, and characterization of an optical fiber sensor based on the surface plasmon resonance (SPR) technique for the simultaneous determination of lead (Pb) and copper (Cu) metal ions in aqueous samples. Two cascade channels over a single optical fiber are fabricated by removing cladding from two well-separated regions of the fiber. SPR working as a transducing mechanism for the sensor is realized by coating thin films of copper and silver over unclad cores of channel I and channel II, respectively. Ion-imprinted nanoparticles for both ions are separately synthesized and coated over the metal-coated unclad cores of the fiber as the recognition layers for sensor fabrication. A first channel having layer of Pb(II) ion-imprinted nanoparticles detects Pb(II) ions and a second channel having layer of Cu(II) ion-imprinted nanoparticles are used for the detection of Cu(II) ions. Both channels are characterized using the wavelength interrogation method. The sensor operates in the range between 0 to 1000 μg/L and 0 to 1000 mg/L for Pb(II) and Cu(II) ions, respectively. These ranges cover water resources and the human body for these ions. The sensitivities of channel I and channel II are found to be 8.19×104 nm/(μg/L) and 4.07×105 nm/(mg/L) near the lowest concentration of Pb(II) and Cu(II) ions, respectively. The sensor can detect concentrations of Pb(II) and Cu(II) ions as low as 4.06 × 10-12 g/L and 8.18 × 10-10 g/L, respectively, which are the least among the reported values in the literature. Further, the probe is simple, cost effective, highly selective, and applicable for online monitoring and remote sensing.

  8. Design layout for gas monitoring system II, GMS-2, computer system

    International Nuclear Information System (INIS)

    Vo, V.; Philipp, B.L.; Manke, M.P.

    1995-01-01

    This document provides a general overview of the computer systems software that perform the data acquisition and control for the 241-SY-101 Gas Monitoring System II (GMS-2). It outlines the system layout, and contains descriptions of components and the functions they perform. The GMS-2 system was designed and implemented by Los Alamos National Laboratory and supplied to Westinghouse Hanford Company

  9. Resonant characteristics and sensitivity dependency on the contact surface in QCM-micropillar-based system of coupled resonator sensors

    International Nuclear Information System (INIS)

    Kashan, M A M; Kalavally, V; Ramakrishnan, N; Lee, H W

    2016-01-01

    We report the characteristics and sensitivity dependence over the contact surface in coupled resonating sensors (CRSs) made of high aspect ratio resonant micropillars attached to a quartz crystal microbalance (QCM). Through experiments and simulation, we observed that when the pillars of resonant heights were placed in maximum displacement regions the resonance frequency of the QCM increased following the coupled resonance characteristics, as the pillar offered elastic loading to the QCM surface. However, the same pillars when placed in relatively lower displacement regions, in spite of their resonant dimension, offered inertial loading and resulted in a decrease in QCM resonance frequency, as the displacement amplitude was insufficient to couple the vibrations from the QCM to the pillars. Accordingly, we discovered that the coupled resonance characteristics not only depend on the resonant structure dimensions but also on the contact regions in the acoustic device. Further analysis revealed that acoustic pressure at the contact surface also influences the resonance frequency characteristics and sensitivity of the CRS. To demonstrate the significance of the present finding for sensing applications, humidity sensing is considered as the example measurand. When a sensing medium made of resonant SU-8 pillars was placed in a maximum displacement region on a QCM surface, the sensitivity increased by 14 times in comparison to a resonant sensing medium placed in a lower displacement region of a QCM surface. (paper)

  10. Resonant characteristics and sensitivity dependency on the contact surface in QCM-micropillar-based system of coupled resonator sensors

    Science.gov (United States)

    Kashan, M. A. M.; Kalavally, V.; Lee, H. W.; Ramakrishnan, N.

    2016-05-01

    We report the characteristics and sensitivity dependence over the contact surface in coupled resonating sensors (CRSs) made of high aspect ratio resonant micropillars attached to a quartz crystal microbalance (QCM). Through experiments and simulation, we observed that when the pillars of resonant heights were placed in maximum displacement regions the resonance frequency of the QCM increased following the coupled resonance characteristics, as the pillar offered elastic loading to the QCM surface. However, the same pillars when placed in relatively lower displacement regions, in spite of their resonant dimension, offered inertial loading and resulted in a decrease in QCM resonance frequency, as the displacement amplitude was insufficient to couple the vibrations from the QCM to the pillars. Accordingly, we discovered that the coupled resonance characteristics not only depend on the resonant structure dimensions but also on the contact regions in the acoustic device. Further analysis revealed that acoustic pressure at the contact surface also influences the resonance frequency characteristics and sensitivity of the CRS. To demonstrate the significance of the present finding for sensing applications, humidity sensing is considered as the example measurand. When a sensing medium made of resonant SU-8 pillars was placed in a maximum displacement region on a QCM surface, the sensitivity increased by 14 times in comparison to a resonant sensing medium placed in a lower displacement region of a QCM surface.

  11. Physics Detector Simulation Facility Phase II system software description

    International Nuclear Information System (INIS)

    Scipioni, B.; Allen, J.; Chang, C.; Huang, J.; Liu, J.; Mestad, S.; Pan, J.; Marquez, M.; Estep, P.

    1993-05-01

    This paper presents the Physics Detector Simulation Facility (PDSF) Phase II system software. A key element in the design of a distributed computing environment for the PDSF has been the separation and distribution of the major functions. The facility has been designed to support batch and interactive processing, and to incorporate the file and tape storage systems. By distributing these functions, it is often possible to provide higher throughput and resource availability. Similarly, the design is intended to exploit event-level parallelism in an open distributed environment

  12. Predictive value of the APACHE II, SAPS II, SOFA and GCS scoring systems in patients with severe purulent bacterial meningitis.

    Science.gov (United States)

    Pietraszek-Grzywaczewska, Iwona; Bernas, Szymon; Łojko, Piotr; Piechota, Anna; Piechota, Mariusz

    2016-01-01

    Scoring systems in critical care patients are essential for predicting of the patient outcome and evaluating the therapy. In this study, we determined the value of the Acute Physiology and Chronic Health Evaluation II (APACHE II), Simplified Acute Physiology Score II (SAPS II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Scale (GCS) scoring systems in the prediction of mortality in adult patients admitted to the intensive care unit (ICU) with severe purulent bacterial meningitis. We retrospectively analysed data from 98 adult patients with severe purulent bacterial meningitis who were admitted to the single ICU between March 2006 and September 2015. Univariate logistic regression identified the following risk factors of death in patients with severe purulent bacterial meningitis: APACHE II, SAPS II, SOFA, and GCS scores, and the lengths of ICU stay and hospital stay. The independent risk factors of patient death in multivariate analysis were the SAPS II score, the length of ICU stay and the length of hospital stay. In the prediction of mortality according to the area under the curve, the SAPS II score had the highest accuracy followed by the APACHE II, GCS and SOFA scores. For the prediction of mortality in a patient with severe purulent bacterial meningitis, SAPS II had the highest accuracy.

  13. High Frequency Resonance Damping of DFIG based Wind Power System under Weak Network

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    When operating in a micro or weak grid which has a relatively large network impedance, the Doubly Fed Induction Generator (DFIG) based wind power generation system is prone to suffer high frequency resonance due to the impedance interaction between DFIG system and the parallel compensated network...... (series RL + shunt C). In order to improve the performance of the DFIG system as well as other units and loads connected to the weak grid, the high frequency resonance needs to be effectively damped. In this paper, the proposed active damping control strategy is able to implement effective damping either...... in the Rotor Side Converter (RSC) or in the Grid Side Converter (GSC), through the introduction of virtual positive capacitor or virtual negative inductor to reshape the DFIG system impedance and mitigate the high frequency resonance. A detailed theoretical explanation on the virtual positive capacitor...

  14. Overview of DFIG-based Wind Power System Resonances under Weak Networks

    DEFF Research Database (Denmark)

    Song, Yipeng; Blaabjerg, Frede

    2017-01-01

    The wind power generation techniques are continuing to develop and increasing numbers of Doubly Fed Induction Generator (DFIG)-based wind power systems are connecting to the on-shore and off-shore grids, local standalone weak networks, and also micro grid applications. The impedances of the weak...... weak network respectively. This paper will discuss the SSR and the HFR phenomena based on the impedance modeling of the DFIG system and the weak networks, and the cause of these two resonances will be explained in details. The following factors including 1) transformer configuration; 2) different power...... networks are too large to be neglected and require careful attention. Due to the impedance interaction between the weak network and the DFIG system, both Sub- Synchronous Resonance (SSR) and High Frequency Resonance (HFR) may occur when the DFIG system is connected to the series or parallel compensated...

  15. System Performance of an Inertially Stabilized Gimbal Platform with Friction, Resonance, and Vibration Effects

    OpenAIRE

    Jia, Ruting; Nandikolla, Vidya K.; Haggart, Gary; Volk, Charles; Tazartes, Daniel

    2017-01-01

    The research work evaluates the quality of the sensor to perform measurements and documents its effects on the performance of the system. It also evaluates if this performance changes due to the environments and other system parameters. These environments and parameters include vibration, system friction, structural resonance, and dynamic system input. The analysis is done by modeling a gimbal camera system that requires angular measurements from inertial sensors and gyros for stabilization. ...

  16. Wide Frequency Band Active Damping Strategy for DFIG System High Frequency Resonance

    DEFF Research Database (Denmark)

    Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    As a popular renewable power generation solution, the Doubly Fed Induction Generator (DFIG) based wind power system may suffer from High Frequency Resonance (HFR) caused by the impedance interaction between the DFIG system and the parallel compensated weak network. A wide frequency band active...... damping strategy for DFIG system HFR, including a high-pass filter and a virtual resistance, is proposed in this paper. The advantages of this active damping strategy are, 1) no resonance frequency detection unit is required, thus the control complexity can be decreased; 2) no active damping parameters...

  17. Urban Integrated Industrial Cogeneration Systems Analysis. Phase II final report

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Through the Urban Integrated Industrial Cogeneration Systems Analysis (UIICSA), the City of Chicago embarked upon an ambitious effort to identify the measure the overall industrial cogeneration market in the city and to evaluate in detail the most promising market opportunities. This report discusses the background of the work completed during Phase II of the UIICSA and presents the results of economic feasibility studies conducted for three potential cogeneration sites in Chicago. Phase II focused on the feasibility of cogeneration at the three most promising sites: the Stockyards and Calumet industrial areas, and the Ford City commercial/industrial complex. Each feasibility case study considered the energy load requirements of the existing facilities at the site and the potential for attracting and serving new growth in the area. Alternative fuels and technologies, and ownership and financing options were also incorporated into the case studies. Finally, site specific considerations such as development incentives, zoning and building code restrictions and environmental requirements were investigated.

  18. Stochastic resonance in a time-delayed asymmetric bistable system with mixed periodic signal

    International Nuclear Information System (INIS)

    Yong-Feng, Guo; Wei, Xu; Liang, Wang

    2010-01-01

    This paper studies the phenomenon of stochastic resonance in an asymmetric bistable system with time-delayed feedback and mixed periodic signal by using the theory of signal-to-noise ratio in the adiabatic limit. A general approximate Fokker–Planck equation and the expression of the signal-to-noise ratio are derived through the small time delay approximation at both fundamental harmonics and mixed harmonics. The effects of the additive noise intensity Q, multiplicative noise intensity D, static asymmetry r and delay time τ on the signal-to-noise ratio are discussed. It is found that the higher mixed harmonics and the static asymmetry r can restrain stochastic resonance, and the delay time τ can enhance stochastic resonance. Moreover, the longer the delay time τ is, the larger the additive noise intensity Q and the multiplicative noise intensity D are, when the stochastic resonance appears. (general)

  19. Effects of time delay on stochastic resonance of the stock prices in financial system

    Science.gov (United States)

    Li, Jiang-Cheng; Li, Chun; Mei, Dong-Cheng

    2014-06-01

    The effect of time delay on stochastic resonance of the stock prices in finance system was investigated. The time delay is introduced into the Heston model driven by the extrinsic and intrinsic periodic information for stock price. The signal power amplification (SPA) was calculated by numerical simulation. The results indicate that an optimal critical value of delay time maximally enhances the reverse-resonance in the behaviors of SPA as a function of long-run variance of volatility or cross correlation coefficient between noises for both cases of intrinsic and extrinsic periodic information. Moreover, in both cases, being a critical value in the delay time, when the delay time takes value below the critical value, reverse-resonance increases with the delay time increasing, however, when the delay time takes value above the critical value, the reverse-resonance decrease with the delay time increasing.

  20. Evaluation of Laser Stabilization and Imaging Systems for LCLS-II - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Barry, Matthew; /Auburn U.

    2015-08-19

    This presentation covers data collected on two commercial laser stabilization systems, Guidestar-II and MRC, and two optical imaging systems. Additionally, general information about LCLS-II and how to go about continuing-testing is covered.

  1. EBR-II Cover Gas Cleanup System upgrade process control system structure

    International Nuclear Information System (INIS)

    Carlson, R.B.; Staffon, J.D.

    1992-01-01

    The Experimental Breeder Reactor II (EBR-II) Cover Gas Cleanup System (CGCS) control system was upgraded in 1991 to improve control and provide a graphical operator interface. The upgrade consisted of a main control computer, a distributed control computer, a front end input/output computer, a main graphics interface terminal, and a remote graphics interface terminal. This paper briefly describes the Cover Gas Cleanup System and the overall control system; describes the main control computer hardware and system software features in more detail; and, then, describes the real-time control tasks, and how they interact with each other, and how they interact with the operator interface task

  2. EBR-II Cover Gas Cleanup System upgrade distributed control and front end computer systems

    International Nuclear Information System (INIS)

    Carlson, R.B.

    1992-01-01

    The Experimental Breeder Reactor II (EBR-II) Cover Gas Cleanup System (CGCS) control system was upgraded in 1991 to improve control and provide a graphical operator interface. The upgrade consisted of a main control computer, a distributed control computer, a front end input/output computer, a main graphics interface terminal, and a remote graphics interface terminal. This paper briefly describes the Cover Gas Cleanup System and the overall control system; gives reasons behind the computer system structure; and then gives a detailed description of the distributed control computer, the front end computer, and how these computers interact with the main control computer. The descriptions cover both hardware and software

  3. Control strategies for DC motors driving rotor dynamic systems through resonance

    Science.gov (United States)

    Bisoi, Alfa; Samantaray, A. K.; Bhattacharyya, Ranjan

    2017-12-01

    Rotor dynamic systems require considerably higher power/torque to accelerate through the structural resonance. However, most sources of mechanical power are non-ideal, i.e., they can only provide a limited amount of power. If there is insufficient power to overcome the resonance then the rotor speed may get caught at resonance and the persistent high vibrations can damage the machine. Various proposed solutions to this problem deal with modifications to the mechanical structure and active/semi-active control of structural parameters. This article proposes modification to the prime mover so that peak available power is delivered exactly at the structural resonance frequency. The limited power/non-ideal prime mover considered in this article is a direct current (DC) motor and the structural resonance happens due to forcing from an eccentric rotor disk and vibrations of a flexible weakly damped foundation. Various control strategies to modify the torque-speed characteristics of permanent magnet, shunt and series wound DC motors to promote escape through resonance are considered. Also, the characteristic curves for rotor/motor speed versus the DC supply voltage are obtained for the considered DC motor types from which the unattainable steady angular speeds and the speed jumps due to Sommerfeld effect are computed. Transient simulations are performed using bond graph models for this multi-energy domain (here, electro-mechanical) system. It is shown that a switched control permitting to switch between shunt and series DC motor configurations gives better regulation over the power delivery at the resonant frequency as well as super-critical operating speeds in the neighborhood of structural resonance.

  4. Resonant retuning of Rabi oscillations in a two-level system

    International Nuclear Information System (INIS)

    Leonov, A.V.; Feranchuk, I.D.

    2009-01-01

    The evolution of a two-level system in a single-mode quantum field is considered beyond the rotating wave approximation. The existence of quasi-degenerate energy levels is shown to influence the essential characteristics of temporal and amplitude Rabi oscillations of the system in a resonant manner. (authors)

  5. Inner-Resonance Conditions for Honeycomb Paperboard Cushioning Packaging System with Critical Component

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2013-01-01

    Full Text Available A dynamic model was proposed for a honeycomb paperboard cushioning packaging system with critical component. Then the coupled equations of the system were solved by the variational iteration method, from which the conditions for inner-resonance were obtained, which should be avoided in the cushioning packaging design.

  6. Data acquisition system for electronic paramagnetic resonance spectrophotometer

    International Nuclear Information System (INIS)

    Pena Eguiluz, R.

    1992-01-01

    In the Atomic and Molecular Physics Laboratory at the Physics Department of the Instituto Nacional de Investigaciones Nucleares (ININ), there is in operation an electronic paramagnetic resonance spectrometer (EPR). This equipment is utilized for determine, the distribution of the absorbed energy intensity for a sample of paramagnetic substance by means of the study and analysis of its emission lines spectrum. The useful information is provided as a graphic result showing the spectrum corresponding to the analyzed sample. In similar devices like this, the researchers problem, trying to get the important information, is a hard and imprecise work, thus, this process of find the ordinate magnitudes of a approximately two hundred points, equal spaced in the spectrum, is carried out completely by hand. After this, the information is captured and processed in a personal computer. As a solution for this problem, an interface in both aspects, hardware and software adaptable to a personal computer, was designed and constructed. This interface is able to: a) To get and digitized the analogical signal, that represents the corresponding spectrum curve. b) It stores the digitized information in files and c) It displays in graphic mode the stored data, and then these are normalized in order to be transferred to a statistics and analytical software packets (Author)

  7. PHASE II VAULT TESTING OF THE ARGONNE RFID SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Willoner, T.; Turlington, R.; Koenig, R.

    2012-06-25

    The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step

  8. Phase II Vault Testing of the Argonne RFID System

    International Nuclear Information System (INIS)

    Willoner, T.; Turlington, R.; Koenig, R.

    2012-01-01

    The U.S. Department of Energy (DOE) (Environmental Management (EM), Office of Packaging and Transportation (EM-45)) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase

  9. Impact of depth and location of the wells on vibrational resonance in a triple-well system

    Science.gov (United States)

    Chen, Zhijuan; Ning, Lijuan

    2018-04-01

    The effect of depth and location of a triple-well potential on vibrational resonance is investigated in a quintic oscillator driven by a low-frequency force and a high-frequency force. The values of low-frequency ω and amplitude g of the high-frequency force at which vibrational resonance occurs are derived both numerically and theoretically. It is found that: as ω varies, at most one resonance takes place and the response amplitude at resonance depends on the depth and the location of the potential wells. When g is altered, the depth and location of wells can control the number of resonances, resulting in two, three and four resonances. The system parameters can be adjusted by controlling the depth and position of the wells to achieve optimum vibrational resonance. Furthermore, the changes induced by these two quantities in the tristable system are found to be richer than those induced in bistable systems.

  10. Earth System Grid II, Turning Climate Datasets into Community Resources

    Energy Technology Data Exchange (ETDEWEB)

    Middleton, Don

    2006-08-01

    The Earth System Grid (ESG) II project, funded by the Department of Energy’s Scientific Discovery through Advanced Computing program, has transformed climate data into community resources. ESG II has accomplished this goal by creating a virtual collaborative environment that links climate centers and users around the world to models and data via a computing Grid, which is based on the Department of Energy’s supercomputing resources and the Internet. Our project’s success stems from partnerships between climate researchers and computer scientists to advance basic and applied research in the terrestrial, atmospheric, and oceanic sciences. By interfacing with other climate science projects, we have learned that commonly used methods to manage and remotely distribute data among related groups lack infrastructure and under-utilize existing technologies. Knowledge and expertise gained from ESG II have helped the climate community plan strategies to manage a rapidly growing data environment more effectively. Moreover, approaches and technologies developed under the ESG project have impacted datasimulation integration in other disciplines, such as astrophysics, molecular biology and materials science.

  11. Effects of error feedback on a nonlinear bistable system with stochastic resonance

    International Nuclear Information System (INIS)

    Li Jian-Long; Zhou Hui

    2012-01-01

    In this paper, we discuss the effects of error feedback on the output of a nonlinear bistable system with stochastic resonance. The bit error rate is employed to quantify the performance of the system. The theoretical analysis and the numerical simulation are presented. By investigating the performances of the nonlinear systems with different strengths of error feedback, we argue that the presented system may provide guidance for practical nonlinear signal processing

  12. Movable intraoperative magnetic resonance imaging incorporating a seismic system.

    Science.gov (United States)

    Akutsu, Hiroyoshi; Yamamoto, Tetsuya; Masuda, Yosuke; Ishikawa, Eiichi; Masumoto, Tomohiko; Matsuda, Masahide; Matsumura, Akira

    2015-08-01

    A high-field ceiling-mounted and movable intraoperative MR imaging (iMRI) can minimize additional risks for MRI and enhance safety by not moving the patient. In this system, hanging the heavy magnet from the ceiling requires structural stability; this stability was confirmed in earlier studies, but not proved during a seismic event. We have installed a 1.5 T movable iMRI system with an incorporated seismic system in our hospital in Japan, a seismic event-prone region. This arrangement is the first in the world, to our knowledge. The objective of this study was to describe the mechanism of this seismic system and the first clinical experience using this system. The seismic system consists of a stabilizer pad that is mounted directly under the magnet, in addition to the structural stability. The seismic system was tested with using a shaker table testing at a test laboratory. Ninety-one patients underwent neurosurgical intervention using this iMRI and seismic system at our hospital. In all patients, intra-, pre, and/or postoperative MR images were successfully obtained, and image quality was excellent. The workflow of moving the magnet and scanning were smooth and unproblematic. We had 169 seismic events in our city during this time period, but had no incidental or accidental events related to the seismic events. With the use of the seismic system, a ceiling-mounted, movable iMRI system can be more safely used. This seismic system may contribute to the spread of movable iMRI systems in countries where seismic events occur. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Evaluation of the SLAP lesion using a low-field (0.2T) magnetic resonance system

    International Nuclear Information System (INIS)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack

    2007-01-01

    To evaluate the diagnostic capabilities of the low-field (0.2T) magnetic resonance (MR) system in the detection of the superior labrum anterior to posterior (SLAP) lesion. One hundred fifty patients underwent magnetic resonance imaging of the shoulder over a 7-month period. Forty-six patients underwent arthroscopic surgery, and the surgical results were correlated with the findings of the MR imaging. Arthroscopic procedures were performed within a mean of 8 days after MR imaging. MR imaging of the shoulder was conducted as follows: shoulder coil; T1-weighted spin echo, coronal-oblique images; T2-weighted gradient echo, coronal-oblique and axial images; and T2-weighted spin echo, coronal oblique and sagittal-oblique images. Prospectively, one radiologist interpreted the MR images. The results of surgery were as follow: SLAP II in 26 shoulders, SLAP III in 1 shoulder, SLAP IV in 1 shoulder, normal labrum in 6 shoulder. For SLAP lesions with a higher grade than type 2, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the low-field MRI were 85.7%, 55.5%. 75%, 71%, and 74%, respectively. There was relatively good agreement for the comparison of the MR results obtained using a low-field MR system with the surgical findings for identifying SLAP lesions

  14. Magnetic resonance imaging findings of paracoccidioidomycosis in the musculoskeletal system.

    Science.gov (United States)

    Savarese, Leonor G; Monsignore, Lucas M; de Andrade Hernandes, Mateus; Martinez, Roberto; Nogueira-Barbosa, Marcello H

    2015-10-01

    To describe magnetic resonance imaging (MRI) findings in musculoskeletal paracoccidioidomycosis (PCM). Retrospective case series study after IRB approval. Two musculoskeletal radiologists reviewed in consensus the MRI findings of 11 patients with microbiologically and/or pathologically proven osteoarticular PCM. The MRI evaluation included discrimination of abnormalities in joints, bones and soft tissues. Mean age of patients was 29 years (10-55 years), eight men and three women. Musculoskeletal involvement was the only or the primary presentation of the disease in seven patients (63%). Osteomyelitis was the most common presentation, with seven cases (63%). Primary arthritis was found in one patient (9%). Isolated extra-articular soft tissue PCM was found in three patients: myositis (2) and subcutaneous infection (1). All cases showed regions with signal intensity higher than or similar to the signal of muscle on T1-weighted images. Penumbra sign was present in five cases (45%). T2-weighted images showed reactive soft tissue oedema in eight cases (72%). Post-gadolinium images showed peripheral (8/9) or heterogeneous (1/9) enhancement. Synovial enhancement was present in all cases of joint involvement (6/6). Lipomatosis arborescens was documented in one case of chronic knee involvement. To our knowledge, this is the first case series describing MRI findings of musculoskeletal PCM. Musculoskeletal involvement was the primary presentation of the disease in most cases, and therefore, neoplasms were initially in the differential diagnosis. Osteomyelitis was the most common presentation, often with secondary involvement of joint and or soft tissue. © 2015 John Wiley & Sons Ltd.

  15. The CMS Level-1 Trigger system for LHC Run II

    CERN Document Server

    Tapper, Alexander

    2017-01-01

    During LHC Run II the centre-of-mass energy of pp collisions has increased up to 13 TeV and the instantaneous luminosity has progressed towards $2 \\times 10^{34} \\rm{cm}^{-2}\\rm{s}^{-1}$. In order to guarantee a successful and ambitious physics programme under these conditions, the CMS trigger system has been upgraded. The upgraded CMS Level-1 trigger is designed to improve performance at high luminosity and large number of simultaneous inelastic collisions per crossing. The trigger design, implementation and commissioning are summarised and performance results are described.

  16. The application of computed tomography and magnetic resonance imaging at diagnostics of the human maxillofacial system

    Science.gov (United States)

    Nikitin, V.; Karavaeva, E.; Cherepennikov, Yu; Miloichikova, I.

    2016-06-01

    The application of computed tomography and magnetic resonance imaging has entered into wide practice at diagnosis of the maxillofacial system. Computed tomography allows us to obtain information about only bone structures. Magnetic resonance imaging gives information about bone and soft tissue structures of the maxillofacial system. The sagittal and coronal projections should make for complete diagnosis of the temporomandibular joint, because the articular disc is very mobile structure. We suggest that the temporomandibular joint can influences the internal carotid artery at medial displacement of the articular disc. As a result of analysis of the literature and our own studies concluded that changes TMJ affect the internal carotid artery.

  17. Developing a magnetic resonance imaging scoring system for peripheral psoriatic arthritis

    DEFF Research Database (Denmark)

    McQueen, Fiona; Lassere, Marissa; Bird, Paul

    2007-01-01

    We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy, and ext......We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy...

  18. Equivalent circuit for the characterization of the resonance mode in piezoelectric systems

    Science.gov (United States)

    Fernández-Afonso, Y.; García-Zaldívar, O.; Calderón-Piñar, F.

    2015-12-01

    The impedance properties in polarized piezoelectric can be described by electric equivalent circuits. The classic circuit used in the literature to describe real systems is formed by one resistor (R), one inductance (L) and one capacitance C connected in series and one capacity (C0) connected in parallel with the formers. Nevertheless, the equation that describe the resonance and anti-resonance frequencies depends on a complex manner of R, L, C and C0. In this work is proposed a simpler model formed by one inductance (L) and one capacity (C) in series; one capacity (C0) in parallel; one resistor (RP) in parallel and one resistor (RS) in series with other components. Unlike the traditional circuit, the equivalent circuit elements in the proposed model can be simply determined by knowing the experimental values of the resonance frequency fr, anti-resonance frequency fa, impedance module at resonance frequency |Zr|, impedance module at anti-resonance frequency |Za| and low frequency capacitance C0, without fitting the impedance experimental data to the obtained equation.

  19. Equivalent circuit for the characterization of the resonance mode in piezoelectric systems

    Directory of Open Access Journals (Sweden)

    Y. Fernández-Afonso

    2015-12-01

    Full Text Available The impedance properties in polarized piezoelectric can be described by electric equivalent circuits. The classic circuit used in the literature to describe real systems is formed by one resistor (R, one inductance (L and one capacitance C connected in series and one capacity (C0 connected in parallel with the formers. Nevertheless, the equation that describe the resonance and anti-resonance frequencies depends on a complex manner of R, L, C and C0. In this work is proposed a simpler model formed by one inductance (L and one capacity (C in series; one capacity (C0 in parallel; one resistor (RP in parallel and one resistor (RS in series with other components. Unlike the traditional circuit, the equivalent circuit elements in the proposed model can be simply determined by knowing the experimental values of the resonance frequency fr, anti-resonance frequency fa, impedance module at resonance frequency |Zr|, impedance module at anti-resonance frequency |Za| and low frequency capacitance C0, without fitting the impedance experimental data to the obtained equation.

  20. On square-wave-driven stochastic resonance for energy harvesting in a bistable system

    Directory of Open Access Journals (Sweden)

    Dongxu Su

    2014-11-01

    Full Text Available Stochastic resonance is a physical phenomenon through which the throughput of energy within an oscillator excited by a stochastic source can be boosted by adding a small modulating excitation. This study investigates the feasibility of implementing square-wave-driven stochastic resonance to enhance energy harvesting. The motivating hypothesis was that such stochastic resonance can be efficiently realized in a bistable mechanism. However, the condition for the occurrence of stochastic resonance is conventionally defined by the Kramers rate. This definition is inadequate because of the necessity and difficulty in estimating white noise density. A bistable mechanism has been designed using an explicit analytical model which implies a new approach for achieving stochastic resonance in the paper. Experimental tests confirm that the addition of a small-scale force to the bistable system excited by a random signal apparently leads to a corresponding amplification of the response that we now term square-wave-driven stochastic resonance. The study therefore indicates that this approach may be a promising way to improve the performance of an energy harvester under certain forms of random excitation.

  1. Investigation based on nano-electromechanical system double Si3N4 resonant beam pressure sensor.

    Science.gov (United States)

    Yang, Chuan; Guo, Can; Yuan, Xiaowei

    2011-12-01

    This paper presents a type of NEMS (Nano-Electromechanical System) double Si3N4 resonant beams pressure sensor. The mathematical models are established in allusion to the Si3N4 resonant beams and pressure sensitive diaphragm. The distribution state of stress has been analyzed theoretically based on the mathematical model of pressure sensitive diaphragm; from the analysis result, the position of the Si3N4 resonant beams above the pressure sensitive diaphragm was optimized and then the dominance observed after the double resonant beams are adopted is illustrated. From the analysis result, the position of the Si3N4 resonant beams above the pressure sensitive diaphragm is optimized, illustrating advantages in the adoption of double resonant beams. The capability of the optimized sensor was generally analyzed using the ANSYS software of finite element analysis. The range of measured pressure is 0-400 Kpa, the coefficient of linearity correlation is 0.99346, and the sensitivity of the sensor is 498.24 Hz/Kpa, higher than the traditional sensors. Finally the processing techniques of the sensor chip have been designed with sample being successfully processed.

  2. Statistics of resonances in one-dimensional continuous systems

    Indian Academy of Sciences (India)

    dimensional continuous open system. The disordered system is semi-infinite, with white-noise random potential, and it is coupled to the external world by a semi-infinite continuous perfect lead. Our main result is an integral representation for the DOR ...

  3. Resonant X-ray scattering in correlated systems

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Youichi [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan). Inst. of Materials Structure Science; Ishihara, Sumio (ed.) [Tohoku Univ., Sendai, Miyagi (Japan). Dept. of Physics

    2017-03-01

    The research and its outcomes presented here is devoted to the use of X-ray scattering to study correlated electron systems and magnetism. Different X-ray based methods are provided to analyze three dimensional electron systems and the structure of transition-metal oxides. Finally the observation of multipole orderings with X-ray diffraction is shown.

  4. Resonant x-ray scattering in correlated systems

    CERN Document Server

    Ishihara, Sumio

    2017-01-01

    The research and its outcomes presented here is devoted to the use of x-ray scattering to study correlated electron systems and magnetism. Different x-ray based methods are provided to analyze three dimensional electron systems and the structure of transition-metal oxides. Finally the observation of multipole orderings with x-ray diffraction is shown.

  5. Microscopic anatomy of pycnogonida: II. Digestive system. III. Excretory system.

    Science.gov (United States)

    Fahrenbach, W H; Arango, Claudia P

    2007-11-01

    The digestive system of several species of sea spiders (Pycnogonida, Arthropoda) was studied by electron microscopy. It is composed of the foregut inside a long proboscis, a midgut and a hindgut. Lips near the three jaws at the tip of the proboscis receive several hundred ductules originating from salivary glands. These previously undetected glands open on the lips, a fluted, projecting ridge at the external hinge line of the jaws, i.e., to the outside of the mouth. This disposition suggests affinities to the chelicerate line. The trigonal esophagus within the proboscis contains a complex, setose filter device, operated by dedicated muscles, that serves to reduce ingested food to subcellular dimensions. The midgut has diverticula into the bases of all legs. Its cells differentiate from the basal layer and contain a bewildering array of secretion droplets, lysosomes and phagosomes. In the absence of a hepatopancreas, the midgut serves both digestive and absorptive functions. The cuticle-lined hindgut lies in the highly reduced, peg-like abdomen. Traditionally, pycnogonids have been claimed to have no excretory organ at all. Such a structure, however, has been located in at least one ammotheid, Nymphopsis spinosissima, in which a simple, but standard, excretory gland has been found in the scape of the chelifore. It consists of an end sac, a straight proximal tubule, a short distal tubule, and a raised nephropore. The end sac is a thin-walled and polygonal chamber, about 150 microm in cross section, suspended in the hemocoel of the appendage, its edges radially tethered to the cuticle at more than half a dozen locations. This wall consists of a filtration basement membrane, 1-4 microm thick, facing the hemocoel, and internally of a continuous carpet of podocytes and their pedicels. The podocytes, measuring maximally 10 by 15 microm, have complex contents, of which a labyrinthine system of connected intracellular channels stands out. These coated cisternae open into a

  6. DYNAMICAL EVOLUTION OF MULTI-RESONANT SYSTEMS: THE CASE OF GJ 876

    Energy Technology Data Exchange (ETDEWEB)

    Batygin, Konstantin; Deck, Katherine M. [Division of Geological and Planetary Sciences, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125 (United States); Holman, Matthew J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States)

    2015-05-15

    The GJ 876 system was among the earliest multi-planetary detections outside of the Solar System, and has long been known to harbor a resonant pair of giant planets. Subsequent characterization of the system revealed the presence of an additional Neptune mass object on an external orbit, locked in a three body Laplace mean motion resonance with the previously known planets. While this system is currently the only known extrasolar example of a Laplace resonance, it differs from the Galilean satellites in that the orbital motion of the planets is known to be chaotic. In this work, we present a simple perturbative model that illuminates the origins of stochasticity inherent to this system and derive analytic estimates of the Lyapunov time as well as the chaotic diffusion coefficient. We then address the formation of the multi-resonant structure within a protoplanetary disk and show that modest turbulent forcing in addition to dissipative effects is required to reproduce the observed chaotic configuration. Accordingly, this work places important constraints on the typical formation environments of planetary systems and informs the attributes of representative orbital architectures that arise from extended disk-driven evolution.

  7. Fabrication and characterization of thermally actuated micromechanical resonators for airborne particle mass sensing: II. Device fabrication and characterization

    International Nuclear Information System (INIS)

    Hajjam, Arash; Rahafrooz, Amir; Pourkamali, Siavash; Wilson, James C

    2010-01-01

    This paper, the second of two parts, presents extensive measurement and characterization results on fabricated thermally actuated single-crystal silicon MEMS resonators analyzed in part I. The resonators have been fabricated using a single mask process on SOI substrates. Resonant frequencies in a few hundreds of kHz to a few MHz and equivalent motional conductances as high as 102 mA V −1 have been measured for the fabricated resonators. The measurement results have been compared to the resonator characteristics predicted by the model developed in part I showing a good agreement between the two. Despite the relatively low frequencies, high quality factors (Q) of the order of a few thousand have been measured for the resonators under atmospheric pressure. The mass sensitivities of some of the resonators were characterized by embedding them in a custom-made test setup and deposition of artificially generated aerosol particles with known size and composition. The resulting measured mass sensitivities are of the order of tens to hundreds of Hz ng −1 and are in agreement with the expected values based on the resonator's physical dimensions. Finally, measurement of mass density of arbitrary airborne particles in the surrounding lab environment has been demonstrated

  8. Coherence resonance in an excitable system with time delay

    International Nuclear Information System (INIS)

    Sethia, Gautam C.; Kurths, Juergen; Sen, Abhijit

    2007-01-01

    We study the noise activated dynamics of a model excitable system that consists of a subcritical Hopf oscillator with a time delayed nonlinear feedback. The coherence of the noise driven pulses of the system exhibits a novel double peaked structure as a function of the noise amplitude. The two peaks correspond to separate optimal noise levels for excitation of single spikes and multiple spikes (bursts) respectively. The relative magnitudes of these peaks are found to be a sensitive function of time delay. The physical significance of our results and its practical implications in various real life systems are discussed

  9. Intelligent control of HVAC systems. Part II: perceptron performance analysis

    Directory of Open Access Journals (Sweden)

    Ioan URSU

    2013-09-01

    Full Text Available This is the second part of a paper on intelligent type control of Heating, Ventilating, and Air-Conditioning (HVAC systems. The whole study proposes a unified approach in the design of intelligent control for such systems, to ensure high energy efficiency and air quality improving. In the first part of the study it is considered as benchmark system a single thermal space HVAC system, for which it is assigned a mathematical model of the controlled system and a mathematical model(algorithm of intelligent control synthesis. The conception of the intelligent control is of switching type, between a simple neural network, a perceptron, which aims to decrease (optimize a cost index,and a fuzzy logic component, having supervisory antisaturating role for neuro-control. Based on numerical simulations, this Part II focuses on the analysis of system operation in the presence only ofthe neural control component. Working of the entire neuro-fuzzy system will be reported in a third part of the study.

  10. A QUICK METHOD TO IDENTIFY SECULAR RESONANCES IN MULTI-PLANET SYSTEMS WITH A BINARY COMPANION

    Energy Technology Data Exchange (ETDEWEB)

    Pilat-Lohinger, E.; Bazsó, A.; Funk, B. [Institute for Astronomy, University of Vienna, Türkenschanzstrasse 17, A-1180 Vienna (Austria)

    2016-11-01

    Gravitational perturbations in multi-planet systems caused by an accompanying star are the subject of this investigation. Our dynamical model is based on the binary star HD 41004 AB where a giant planet orbits HD 41004 A. We modify the orbital parameters of this system and analyze the motion of a hypothetical test planet surrounding HD 41004 A on an interior orbit to the detected giant planet. Our numerical computations indicate perturbations due to mean motion and secular resonances (SRs). The locations of these resonances are usually connected to high eccentricity and highly inclined motion depending strongly on the binary-planet architecture. As the positions of mean motion resonances can easily be determined, the main purpose of this study is to present a new semi-analytical method to determine the location of an SR without huge computational effort.

  11. Reverse resonance in stock prices of financial system with periodic information

    Science.gov (United States)

    Li, Jiang-Cheng; Mei, Dong-Cheng

    2013-07-01

    We investigate the stochastic resonance of the stock prices in a finance system with the Heston model. The extrinsic and intrinsic periodic information are introduced into the stochastic differential equations of the Heston model for stock price by focusing on the signal power amplification (SPA). We find that for both cases of extrinsic and intrinsic periodic information a phenomenon of reverse resonance emerges in the behaviors of SPA as a function of the system and external driving parameters. Moreover, in both cases, a phenomenon of double reverse resonance is observed in the behavior of SPA versus the amplitude of volatility fluctuations, by increasing the cross correlation between the noise sources in the Heston model.

  12. Localized surface plasmon resonance mercury detection system and methods

    Science.gov (United States)

    James, Jay; Lucas, Donald; Crosby, Jeffrey Scott; Koshland, Catherine P.

    2016-03-22

    A mercury detection system that includes a flow cell having a mercury sensor, a light source and a light detector is provided. The mercury sensor includes a transparent substrate and a submonolayer of mercury absorbing nanoparticles, e.g., gold nanoparticles, on a surface of the substrate. Methods of determining whether mercury is present in a sample using the mercury sensors are also provided. The subject mercury detection systems and methods find use in a variety of different applications, including mercury detecting applications.

  13. Förster resonance energy transfer, absorption and emission spectra in multichromophoric systems. III. Exact stochastic path integral evaluation.

    Science.gov (United States)

    Moix, Jeremy M; Ma, Jian; Cao, Jianshu

    2015-03-07

    A numerically exact path integral treatment of the absorption and emission spectra of open quantum systems is presented that requires only the straightforward solution of a stochastic differential equation. The approach converges rapidly enabling the calculation of spectra of large excitonic systems across the complete range of system parameters and for arbitrary bath spectral densities. With the numerically exact absorption and emission operators, one can also immediately compute energy transfer rates using the multi-chromophoric Förster resonant energy transfer formalism. Benchmark calculations on the emission spectra of two level systems are presented demonstrating the efficacy of the stochastic approach. This is followed by calculations of the energy transfer rates between two weakly coupled dimer systems as a function of temperature and system-bath coupling strength. It is shown that the recently developed hybrid cumulant expansion (see Paper II) is the only perturbative method capable of generating uniformly reliable energy transfer rates and emission spectra across a broad range of system parameters.

  14. Study on efficiency of different topologies of magnetic coupled resonant wireless charging system

    Science.gov (United States)

    Cui, S.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Yue, Z. K.; Liang, L. H.

    2017-11-01

    This paper analyses the relationship between the output power, the transmission efficiency and the frequency, load and coupling coefficient of the four kinds of magnetic coupled resonant wireless charging system topologies. Based on mutual inductance principle, four kinds of circuit models are established, and the expressions of output power and transmission efficiency of different structures are calculated. The difference between the two power characteristics and efficiency characteristics is compared by simulating the SS (series-series) and SP (series-parallel) type wireless charging systems. With the same parameters of circuit components, the SS structure is usually suitable for small load resistance. The SP structure can be applied to large load resistors, when the transmission efficiency of the system is required to keep high. If the operating frequency deviates from the system resonance frequency, the SS type system has higher transmission efficiency than the SP type system.

  15. Defect-related internal dissipation in mechanical resonators and the study of coupled mechanical systems.

    Energy Technology Data Exchange (ETDEWEB)

    Friedmann, Thomas Aquinas; Czaplewski, David A.; Sullivan, John Patrick; Modine, Normand Arthur; Wendt, Joel Robert; Aslam, Dean (Michigan State University, Lansing, MI); Sepulveda-Alancastro, Nelson (University of Puerto Rico, Mayaguez, PR)

    2007-01-01

    Understanding internal dissipation in resonant mechanical systems at the micro- and nanoscale is of great technological and fundamental interest. Resonant mechanical systems are central to many sensor technologies, and microscale resonators form the basis of a variety of scanning probe microscopies. Furthermore, coupled resonant mechanical systems are of great utility for the study of complex dynamics in systems ranging from biology to electronics to photonics. In this work, we report the detailed experimental study of internal dissipation in micro- and nanomechanical oscillators fabricated from amorphous and crystalline diamond materials, atomistic modeling of dissipation in amorphous, defect-free, and defect-containing crystalline silicon, and experimental work on the properties of one-dimensional and two-dimensional coupled mechanical oscillator arrays. We have identified that internal dissipation in most micro- and nanoscale oscillators is limited by defect relaxation processes, with large differences in the nature of the defects as the local order of the material ranges from amorphous to crystalline. Atomistic simulations also showed a dominant role of defect relaxation processes in controlling internal dissipation. Our studies of one-dimensional and two-dimensional coupled oscillator arrays revealed that it is possible to create mechanical systems that should be ideal for the study of non-linear dynamics and localization.

  16. Secular dynamics of multiplanetary circumbinary systems: stationary solutions and binary-planet secular resonance

    Science.gov (United States)

    Andrade-Ines, Eduardo; Robutel, Philippe

    2018-01-01

    We present an analytical formalism to study the secular dynamics of a system consisting of N-2 planets orbiting a binary star in outer orbits. We introduce a canonical coordinate system and expand the disturbing function in terms of canonical elliptic elements, combining both Legendre polynomials and Laplace coefficients, to obtain a general formalism for the secular description of this type of configuration. With a quadratic approximation of the development, we present a simplified analytical solution for the planetary orbits for both the single planet and the two-planet cases. From the two-planet model, we show that the inner planet accelerates the precession rate of the binary pericenter, which, in turn, may enter in resonance with the secular frequency of the outer planet, characterizing a secular resonance. We calculate an analytical expression for the approximate location of this resonance and apply it to known circumbinary systems, where we show that it can occur at relatively close orbits, for example at 2.4 au for the Kepler-38 system. With a more refined model, we analyse the dynamics of this secular resonance and we show that a bifurcation of the corresponding fixed points can affect the long- term evolution and stability of planetary systems. By comparing our results with complete integrations of the exact equations of motion, we verified the accuracy of our analytical model.

  17. Power conversion distribution system using a resonant high-frequency AC link

    Science.gov (United States)

    Sood, P. K.; Lipo, T. A.

    1986-01-01

    Static power conversion systems based on a resonant high frequency (HF) link offers a significant reduction in the size and weight of the equipment over that achieved with conventional approaches, especially when multiple sources and loads are to be integrated. A faster system response and absence of audible noise are the other principal characteristics of such systems. A conversion configuration based on a HF link which is suitable for applications requiring distributed power is proposed.

  18. Analysis and Comparison of High Frequency Resonance in Small and Large Scale DFIG System

    OpenAIRE

    Song, Yipeng; Blaabjerg, Frede; Wang, Xiongfei

    2016-01-01

    When connected to a parallel compensated weak grid network, both the small and large power scale Doubly Fed Induction Generator (DFIG) system may suffer high frequency resonance (HFR) due to the impedance interaction between the DFIG system and the parallel compensated weak network. Since the parameters of the small and large scale DFIG systems, including DFIG machine parameters and the LCL filter parameters, may vary between 10 to 100 times, the impedance modeling results of small and large ...

  19. Self-organizing systems in planetary physics: Harmonic resonances of planet and moon orbits

    Science.gov (United States)

    Aschwanden, Markus J.

    2018-01-01

    The geometric arrangement of planet and moon orbits into a regularly spaced pattern of distances is the result of a self-organizing system. The positive feedback mechanism that operates a self-organizing system is accomplished by harmonic orbit resonances, leading to long-term stable planet and moon orbits in solar or stellar systems. The distance pattern of planets was originally described by the empirical Titius-Bode law, and by a generalized version with a constant geometric progression factor (corresponding to logarithmic spacing). We find that the orbital periods Ti and planet distances Ri from the Sun are not consistent with logarithmic spacing, but rather follow the quantized scaling (Ri + 1 /Ri) =(Ti + 1 /Ti) 2 / 3 =(Hi + 1 /Hi) 2 / 3 , where the harmonic ratios are given by five dominant resonances, namely (Hi + 1 :Hi) =(3 : 2) ,(5 : 3) ,(2 : 1) ,(5 : 2) ,(3 : 1) . We find that the orbital period ratios tend to follow the quantized harmonic ratios in increasing order. We apply this harmonic orbit resonance model to the planets and moons in our solar system, and to the exo-planets of 55 Cnc and HD 10180 planetary systems. The model allows us a prediction of missing planets in each planetary system, based on the quasi-regular self-organizing pattern of harmonic orbit resonance zones. We predict 7 (and 4) missing exo-planets around the star 55 Cnc (and HD 10180). The accuracy of the predicted planet and moon distances amounts to a few percents. All analyzed systems are found to have ≈ 10 resonant zones that can be occupied with planets (or moons) in long-term stable orbits.

  20. Features of the effect of the parameters of resonance systems with different configurations on the current-voltage characteristics of resonant-tunneling nanostructures in a subterahertz frequency range

    International Nuclear Information System (INIS)

    Aleksanyan, A.A.; Volchkov, N.A.; Dravin, V.A.; Kazakov, I.P.; Karuzskij, A.L.; Murzin, V.N.; Perestoronin, A.V.; Tskhovrebov, A.M.; Shmelev, S.S.

    2014-01-01

    Features of the effect of a subterahertz microwave field on the current characteristics of a resonant-tunneling diode in resonance systems with different configurations have been studied. Changes in the current characteristics of the resonant-tunneling diode under variation of the electrophysical parameters of dielectric and microstrip resonators, in particular high-Q-factor superconducting microstrip resonators, have been experimentally studied and analyzed [ru

  1. KBGIS-II: A knowledge-based geographic information system

    Science.gov (United States)

    Smith, Terence; Peuquet, Donna; Menon, Sudhakar; Agarwal, Pankaj

    1986-01-01

    The architecture and working of a recently implemented Knowledge-Based Geographic Information System (KBGIS-II), designed to satisfy several general criteria for the GIS, is described. The system has four major functions including query-answering, learning and editing. The main query finds constrained locations for spatial objects that are describable in a predicate-calculus based spatial object language. The main search procedures include a family of constraint-satisfaction procedures that use a spatial object knowledge base to search efficiently for complex spatial objects in large, multilayered spatial data bases. These data bases are represented in quadtree form. The search strategy is designed to reduce the computational cost of search in the average case. The learning capabilities of the system include the addition of new locations of complex spatial objects to the knowledge base as queries are answered, and the ability to learn inductively definitions of new spatial objects from examples. The new definitions are added to the knowledge base by the system. The system is performing all its designated tasks successfully. Future reports will relate performance characteristics of the system.

  2. The NSLS-II Multilayer Laue Lens Deposition System

    International Nuclear Information System (INIS)

    Conley, R.; Bouet, N.; Biancarosa, J.; Shen, Q.; Boas, L.; Feraca, J.; Rosenbaum, L.

    2009-01-01

    The NSLS-II(1) program has a requirement for an unprecedented level of x-ray nanofocusing and has selected the wedged multilayer Laue lens(2,3) (MLL) as the optic of choice to meet this goal. In order to fabricate the MLL a deposition system is required that is capable of depositing depth-graded and laterally-graded multilayers with precise thickness control over many thousands of layers, with total film growth in one run up to 100 m thick or greater. This machine design expounds on the positive features of a rotary deposition system(4) constructed previously for MLLs and will contain multiple stationary, horizontally-oriented magnetron sources where a transport will move a substrate back and forth in a linear fashion over shaped apertures at well-defined velocities to affect a multilayer coating.

  3. Magnetic Resonance Spectroscopy in evaluation of central nervous system

    International Nuclear Information System (INIS)

    Krolicki, L.; Bak, M.; Grieb, P.

    1996-01-01

    The article presents the current results of MR spectroscopy in evaluation of central nervous system. This method is useful in examination of brain ischemia, brain tumors, epilepsy; white matter disorders and degeneration diseases. MR spectroscopy is unique technique for in vivo examination of the brain in physiological and pathophysiological states. (author)

  4. System-Level Design Considerations for Carbon Nanotube Electromechanical Resonators

    Directory of Open Access Journals (Sweden)

    Christian Kauth

    2013-01-01

    Full Text Available Despite an evermore complete plethora of complex domain-specific semiempirical models, no succinct recipe for large-scale carbon nanotube electromechanical systems design has been formulated. To combine the benefits of these highly sensitive miniaturized mechanical sensors with the vast functionalities available in electronics, we identify a reduced key parameter set of carbon nanotube properties, nanoelectromechanical system design, and operation that steers the sensor’s performance towards system applications, based on open- and closed-loop topologies. Suspended single-walled carbon nanotubes are reviewed in terms of their electromechanical properties with the objective of evaluating orders of magnitude of the electrical actuation and detection mechanisms. Open-loop time-averaging and 1ω or 2ω mixing methods are completed by a new 4ω actuation and detection technique. A discussion on their extension to closed-loop topologies and system applications concludes the analysis, covering signal-to-noise ratio, and the capability to spectrally isolate the motional information from parasitical feedthrough by contemporary electronic read-out techniques.

  5. Crossover from plasmonic analogue of Fano resonance to Autler-Townes splitting in a double guide mode resonances system

    Science.gov (United States)

    Wei, Buzheng; Ren, Guobin; Jian, Shuisheng

    2017-09-01

    The plasmonic analogy from Fano resonance to Autler-Townes splitting (ATS) in mid-infrared spectral range is observed assisted by a dual parallel graphene-coated grating structure. The analytical derivation exhibits a height-dependent resonance which is crucial for discerning Fano resonance from ATS. The mechanism of generating a transparency window seeks a trade-off between Fano resonance and ATS at threshold height. While within the critical height, Fano resonance dominates. The Akaike Information Criterion test is used to discern these two effects quantitatively. Moreover, the device pronounces a good tunability accompanied with a slowing light application. Our ideas open up a new insight view of designing or constructing highly integrated, multi-functional graphene-based metamaterials in nanoscale.

  6. An automated framework for NMR resonance assignment through simultaneous slice picking and spin system forming

    KAUST Repository

    Abbas, Ahmed

    2014-04-19

    Despite significant advances in automated nuclear magnetic resonance-based protein structure determination, the high numbers of false positives and false negatives among the peaks selected by fully automated methods remain a problem. These false positives and negatives impair the performance of resonance assignment methods. One of the main reasons for this problem is that the computational research community often considers peak picking and resonance assignment to be two separate problems, whereas spectroscopists use expert knowledge to pick peaks and assign their resonances at the same time. We propose a novel framework that simultaneously conducts slice picking and spin system forming, an essential step in resonance assignment. Our framework then employs a genetic algorithm, directed by both connectivity information and amino acid typing information from the spin systems, to assign the spin systems to residues. The inputs to our framework can be as few as two commonly used spectra, i.e., CBCA(CO)NH and HNCACB. Different from the existing peak picking and resonance assignment methods that treat peaks as the units, our method is based on \\'slices\\', which are one-dimensional vectors in three-dimensional spectra that correspond to certain (N, H) values. Experimental results on both benchmark simulated data sets and four real protein data sets demonstrate that our method significantly outperforms the state-of-the-art methods while using a less number of spectra than those methods. Our method is freely available at http://sfb.kaust.edu.sa/Pages/Software.aspx. © 2014 Springer Science+Business Media.

  7. Tissue culture system using a PANDA ring resonator and wavelength router for hydroponic plant.

    Science.gov (United States)

    Kamoldilok, Surachart; Suwanpayak, Nathaporn; Suttirak, Saisudawan; Yupapin, Preecha P

    2012-06-01

    A novel system of nanofluidics trapping and delivery, which is known as a tissue culture system is proposed. By using the intense optical pulse(i.e., a soliton pulse) and a system constructed by a liquid core waveguide, the optical vortices (gradient optical fields/wells) can be generated, where the trapping tools in the same way as the optical tweezers in the PANDA ring resonator can be formed. By controlling the suitable parameters, the intense optical vortices can be generated within the PANDA ring resonator, in which the nanofluidics can be trapped and moved (transported) dynamically within the Tissue culture system(a wavelength router), which can be used for tissue culture and delivery in the hydroponic plant system.

  8. The longitudinal reliability and responsiveness of the OMERACT Hand Osteoarthritis Magnetic Resonance Imaging Scoring System (HOAMRIS)

    DEFF Research Database (Denmark)

    Haugen, Ida K.; Eshed, Iris; Gandjbakhch, Frederique

    2015-01-01

    Objective. To evaluate the interreader reliability of change scores and the responsiveness of the OMERACT Hand Osteoarthritis (OA) Magnetic Resonance Image (MRI) Scoring System (HOAMRIS). Methods. Paired MRI (baseline and 5-yr followup) from 20 patients with hand OA were scored with known time se...

  9. Modeling and analysis of harmonic resonance in a power electronics based AC power system

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2013-01-01

    -based analysis approach is adopted and expanded to a meshed and balanced three-phase power network. An impedance ratio derivation method is proposed based on the nodal admittance matrix. By this means, the contribution of each inverter to the system resonance modes can be easily predicted by the Nyquist...

  10. Resonant coherent quantum tunneling of the magnetization of spin-systems: Spin-parity effects

    NARCIS (Netherlands)

    Garcia-Pablos, D; Garcia, N; de Raedt, H.A.

    1997-01-01

    We perform quantum dynamical calculations to study the reversal of the magnetization for systems of a few the presence of an external magnetic field at T=0 and with no dissipation. Collective quantum tunneling of the magnetization is demonstrated to occur only for some specific resonant values of

  11. Conventional magnetic resonance imaging in confirmed progressive supranuclear palsy and multiple system atrophy

    NARCIS (Netherlands)

    Massey, L.A.; Micallef, C.; Paviour, D.C.; O'Sullivan, S.S.; Ling, H.; Williams, D.R.; Kallis, C.; Holton, J.L.; Revesz, T.; Burn, D.J.; Yousry, T.; Lees, A.J.; Fox, N.C.; Jäger, H.R.

    2012-01-01

    Conventional magnetic resonance imaging (cMRI) is often used to aid the diagnosis of progressive supranuclear palsy (PSP) and multiple system atrophy (MSA), but its ability to predict the histopathological diagnosis has not been systematically studied. cMRI from 48 neuropathologically confirmed

  12. Resonant soft x-ray scattering and charge density waves in correlated systems

    NARCIS (Netherlands)

    Rusydi, Andrivo

    2006-01-01

    Summary This work describes results obtained on the study of charge density waves (CDW) in strongly correlated systems with a new experimental method: resonant soft x-ray scattering (RSXS). The basic motivation is the 1986 discovery by Bednorz and Müler of a new type of superconductor, based on Cu

  13. Non-integrability of first order resonances in Hamiltonian systems in three degrees of freedom

    Science.gov (United States)

    Christov, Ognyan

    2012-02-01

    The normal forms of the Hamiltonian 1:2: ω resonances to degree three for ω = 1, 3, 4 are studied for integrability. We prove that these systems are non-integrable except for the discrete values of the parameters which are well known. We use the Ziglin-Morales-Ramis method based on the differential Galois theory.

  14. Optimized design of resonant controller for stator current harmonic compensation in DFIG wind turbine systems

    DEFF Research Database (Denmark)

    Liu, Changjin; Chen, Wenjie; Blaabjerg, Frede

    2012-01-01

    This paper presents an analytical method to optimize the parameters of resonant controller which is used in a Doubly-Fed Induction Generator (DFIG). In the DFIG control system, the fundamental current loop is controlled by PI-controllers, and the stator harmonic current loop is controlled...

  15. Intense Interactions of Molecules with a Short-Wavelength Electromagnetic Radiation Field: II. Resonance Scattering of Radiation and Fluorescence

    Science.gov (United States)

    Pegarkov, A. I.

    2001-07-01

    Within the framework of the nonadiabatic approach developed in the preceding paper, the resonance scattering, resonance Raman scattering, and resonance fluorescence are studied in detail for diatomic and triatomic molecules, and polyatomic symmetric and antisymmetric top molecules, which interact with the field of short-wavelength radiation with a wavelength λ ≥ Å and an intensity up to 1014 W/cm2. The coherent excitations of high-lying Rydberg and autoionizing states are taken into account. Analytical expressions for calculating the tensors and cross sections of the above processes are derived.

  16. Amplification of weak signals via the non-adiabatic regime of stochastic resonance in a bistable dynamical system with time delay

    International Nuclear Information System (INIS)

    Du Luchun; Mei Dongcheng

    2011-01-01

    The non-adiabatic regime of stochastic resonance (SR) in a bistable system with time delay, an additive white noise and a periodic signal was investigated. The signal power amplification η was employed to characterize the SR of the system. The simulation results indicate that (i) in the case of intermediate frequency Ω of the periodic signal, the typical behavior of SR is lowered monotonically by increasing the delay time τ; in the case of large Ω, τ weakens the SR behavior and then enhances it, with a non-monotonic behavior as a function of time delay; (ii) time delay induces SR when A is above the threshold, whereas no such resonance exists in the absence of time delay; (iii) time delay induces a transition from bimodal to unimodal configuration of η; (iv) varying the particular form of time delay results in different phenomena.

  17. The data acquisition system of the Belle II Pixel Detector

    Science.gov (United States)

    Münchow, D.; Dingfelder, J.; Geßler, T.; Konorov, I.; Kühn, W.; Lange, S.; Lautenbach, K.; Levit, D.; Liu, Z.; Marinas, C.; Schnell, M.; Spruck, B.; Zhao, J.

    2014-08-01

    At the future Belle II experiment the DEPFET (DEPleted Field Effect Transistor) pixel detector will consist of about 8 million channels and is placed as the innermost detector. Because of its small distance to the interaction region and the high luminosity in Belle II, for a trigger rate of about 30 kHz with an estimated occupancy of about 3 % a data rate of about 22 GB/s is expected. Due to the high data rate, a data reduction factor higher than 30 is needed in order to stay inside the specifications of the event builder. The main hardware to reduce the data rate is a xTCA based Compute Node (CN) developed in cooperation between IHEP Beijing and University Giessen. Each node has as main component a Xilinx Virtex-5 FX70T FPGA and is equipped with 2 × 2 GB RAM , GBit Ethernet and 4 × 6.25 Gb/s optical links. An ATCA carrier board is able to hold up to four CN and supplies high bandwidth connections between the four CNs and to the ATCA backplane. To achieve the required data reduction on the CNs, regions of interest (ROI) are used. These regions are calculated in two independent systems by projecting tracks back to the pixel detector. One is the High Level Trigger (HLT) which uses data from the Silicon Vertex Detector (SVD), a silicon strip detector, and outer detectors. The other is the Data Concentrator (DATCON) which calculates ROIs based on SVD data only, in order to get low momentum tracks. With this information, only PXD data inside these ROIs will be forwarded to the event builder, while data outside of these regions will be discarded. First results of the test beam time in January 2014 at DESY with a Belle II vertex detector prototype and full DAQ chain will be presented.

  18. International workshop on resonant X-ray scattering in electrically-ordered systems

    International Nuclear Information System (INIS)

    Collins, S.P.; Pettifer, R.F.; Laundy, D.; Ishida, K.; Kokubun, J.; Giles, C.; Yokaichiya, F.; Song, C.; Lee, K.B.; Ji, S.; Koo, J.; Park, Y.J.; Kim, J.Y.; Park, J.H.; Shin, H.J.; Rhyee, J.S.; Oh, B.H.; Cho, B.K.; Wilkins Stuart, B.; Paixao, J.A.; Caciuffo, R.; Javorsky, P.; Wastin, F.; Rebizant, J.; Detlefs, C.; Bernheoft, N.; Lander, G.H.; Bombardi, A.; Bergevin, F. de; Matteo, S. di; Paolasini, L.; Rodriguez-Carvajal, J.; Carretta, P.; Millet, P.; Caciuffo, R.; Goff, J.P.; Deen, P.P.; Lee, S.; Stunault, A.; Brown, S.; Mannix, D.; McIntyre, G.J.; Ward, R.C.C.; Wells, M.R.; Lorenzo, J.E.; Joly, Y.; Nazarenko, E.; Staub, U.; Srajer, G.; Haskel, D.; Choi, Y.; Lee, D.R.; Lang, J.C.; Meersschaut, J.; Jiang, J.S.; Bader, S.D.; Bouchenoire, L.; Brown, S.D.; Beesley, A.; Herring, A.; Thomas, M.; Thompson, P.; Langridge, S.; Stirling, W.G.; Mirone, A.; Lander, G.; Wilkins, S.; Ward, R.C.C.; Wells, M.R.; Zochowski, S.W.; Garcia, J.; Subias, G.; Blasco, J.; Sanchez, M.C.; Proietti, M.G.; Lovesey, S.W.; Dmitrienko, V.E.; Ovchinnikova, E.N.; Ishida, K.; Kokubun, J.; Kirfel, A.; Collins, S.P.; Laundy, D.; Oreshko, A.P.; Strange, P.; Horne, M.; Arola, E.; Winter, H.; Szotek, Z.; Temmerman, W.M.; Igarashi, J.; Usuda, M.; Takahashi, M.; Matteo, S. di; Bernhoeft, N.; Hill, J.P.; Lang, J.C.; McWhan, D.; Lee, D.R.; Haskel, D.; Srajer, G.; Hatton Peter, D.; Katsumata, K.; Braithwaite, D.

    2004-01-01

    The research field of Resonant X-ray Scattering (RXS) has achieved tremendous progress in the last years. Nowadays RXS is rapidly becoming the crucial technique for investigating the subtleties of microscopic magnetism in systems where the ground state properties reflect a delicate balance between several different correlated processes. The aim of this workshop is to discuss present and future possibilities for RXS investigations of electronic order, including studies of charge, magnetic, and multipolar ordered states. The sessions will cover experimental and theoretical aspects of hard and soft X-ray resonant scattering from single crystals and thin films. This document gathers the summaries of the presentations

  19. Analysis of the Behavior of Undamped and Unstable High-Frequency Resonance in DFIG System

    DEFF Research Database (Denmark)

    Song, Yipeng; Blaabjerg, Frede

    2017-01-01

    As the wind power generation develops, the Doubly Fed Induction Generator (DFIG) based wind power system may suffer Sub Synchronous Resonance (SSR) and High Frequency Resonance (HFR) in the series and parallel compensated weak network. The principle and frequency of HFR have been discussed using...... the Bode diagram as an analysis tool. However, the HFR can be categorized into two different types: undamped HFR (which exists in steady state) and unstable HFR (which eventually results in complete instability and divergence), both of them are not investigated before. Since both the undamped HFR...

  20. Pulse mode actuation-readout system based on MEMS resonator for liquid sensing

    DEFF Research Database (Denmark)

    Tang, Meng; Cagliani, Alberto; Davis, Zachary James

    2014-01-01

    A MEMS (Micro-Electro-Mechanical Systems) bulk disk resonator is applied for mass sensing under its dynamic mode. The classical readout circuitry involves sophisticated feedback loop and feedthrough compensation. We propose a simple straightforward non-loop pulse mode actuation and capacitive...... readout scheme. In order to verify its feasibility in liquid bio-chemical sensing environment, an experimental measurement is conducted with humidity sensing application. The measured resonant frequency changes 60kHz of 67.7MHz with a humidity change of 0~80%....

  1. Magnetic and resonant X-ray scattering investigations of strongly correlated electron systems

    International Nuclear Information System (INIS)

    Paolasini, L.; Bergevin, F. de

    2008-01-01

    Resonant X-ray scattering is a method which combines high-Q resolution X-ray elastic diffraction and atomic core-hole spectroscopy for investigating electronic and magnetic long-range ordered structures in condensed matter. During recent years the development of theoretical models to describe resonant X-ray scattering amplitudes and the evolution of experimental techniques, which include the control and analysis of linear photon polarization and the introduction of extreme environment conditions such as low temperatures, high magnetic field and high pressures, have opened a new field of investigation in the domain of strongly correlated electron systems. (authors)

  2. SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Magda, Karoly [ORNL

    2018-01-01

    This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended.It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similar regime, with a slightly alkaline pH of 7.5 , low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time.It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH.

  3. Noise-induced transitions and resonant effects in nonlinear systems

    Science.gov (United States)

    Zaikin, Alexei

    2003-02-01

    Our every-day experience is connected with different acoustical noise or music. Usually noise plays the role of nuisance in any communication and destroys any order in a system. Similar optical effects are known: strong snowing or raining decreases quality of a vision. In contrast to these situations noisy stimuli can also play a positive constructive role, e.g. a driver can be more concentrated in a presence of quiet music. Transmission processes in neural systems are of especial interest from this point of view: excitation or information will be transmitted only in the case if a signal overcomes a threshold. Dr. Alexei Zaikin from the Potsdam University studies noise-induced phenomena in nonlinear systems from a theoretical point of view. Especially he is interested in the processes, in which noise influences the behaviour of a system twice: if the intensity of noise is over a threshold, it induces some regular structure that will be synchronized with the behaviour of neighbour elements. To obtain such a system with a threshold one needs one more noise source. Dr. Zaikin has analyzed further examples of such doubly stochastic effects and developed a concept of these new phenomena. These theoretical findings are important, because such processes can play a crucial role in neurophysics, technical communication devices and living sciences. Unsere alltägliche Erfahrung ist mit verschiedenen akustischen Einfluessen wie Lärm, aber auch Musik verbunden. Jeder weiss, wie Lärm stören kann und Kommunikation behindert oder gar unterbindet. Ähnliche optische Effekte sind bekannt: starkes Schneetreiben oder Regengüsse verschlechtern die Sicht und lassen uns Umrisse nur noch schemenhaft erkennen. Jedoch koennen ähnliche Stimuli auch sehr positive Auswirkungen haben: Autofahrer fahren bei leiser Musik konzentrierter -- die Behauptung von Schulkindern, nur bei dröhnenden Bässen die Mathehausaufgaben richtig rechnen zu können, ist allerdings nicht wissenschaftlich

  4. Breast imaging and reporting data system (BIRADS): magnetic resonance imaging.

    Science.gov (United States)

    Tardivon, Anne A; Athanasiou, Alexandra; Thibault, Fabienne; El Khoury, Carl

    2007-02-01

    This article reviews the technical aspects and interpretation criteria in breast MR imaging based on the first edition of breast imaging and reporting data system (BIRADS) published by the American College of Radiology (ACR) in 2003. In a second article, practical cases will be proposed for training the readers. The major aims of using this lexicon are: first to use a logical and standardized description of MR lesions, secondly to obtain a structured MR report with a clear final impression (BIRADS assessment categories), and thirdly to help comparison between different clinical studies based on similar breast MRI terminology.

  5. Breast imaging and reporting data system (BIRADS): Magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tardivon, Anne A. [Department of Radiology, Institut Curie, 26 rue d' Ulm, 75248 Paris Cedex 05 (France)]. E-mail: anne.tardivon@curie.net; Athanasiou, Alexandra [Department of Radiology, Institut Curie, 26 rue d' Ulm, 75248 Paris Cedex 05 (France); Thibault, Fabienne [Department of Radiology, Institut Curie, 26 rue d' Ulm, 75248 Paris Cedex 05 (France); El Khoury, Carl [Department of Radiology, Institut Curie, 26 rue d' Ulm, 75248 Paris Cedex 05 (France)

    2007-02-15

    This article reviews the technical aspects and interpretation criteria in breast MR imaging based on the first edition of breast imaging and reporting data system (BIRADS) published by the American College of Radiology (ACR) in 2003. In a second article, practical cases will be proposed for training the readers. The major aims of using this lexicon are: first to use a logical and standardized description of MR lesions, secondly to obtain a structured MR report with a clear final impression (BIRADS assessment categories), and thirdly to help comparison between different clinical studies based on similar breast MRI terminology.

  6. Multiple-quantum nuclear magnetic resonance studies of sodium-23 in model and biological systems

    Energy Technology Data Exchange (ETDEWEB)

    Pekar, J.J.

    1988-01-01

    Time-domain multiple-quantum nuclear magnetic resonance spectroscopy is applied to sodium-23 in gels, liquid crystals, cell suspensions, and intact human limbs. In many biological systems, interactions between the nuclear electric quadrupole moment and fluctuating electric field gradients cause the outer transitions, which contribute 60% of the nuclear magnetic resonance signal from the spin-3/2 nuclei, to relax faster than the central transition, which contributes the remains in 40% of the signal. New multiple-quantum experiments, designed specifically for quadrupolar spin-3/2 nuclei, reveal much information not usually available from conventional nuclear magnetic resonance spectroscopy, because they allow indirect measurement of the rapid relaxation rate of the outer transitions, and may highlight the distribution of sodium ions among microscopic physiological compartments such as intracellular space, the interstitium, and the vasculature. The use of venous occlusion plethysmography to alter this distribution is discussed.

  7. Transmission-line resonators for the study of individual two-level tunneling systems

    Science.gov (United States)

    Brehm, Jan David; Bilmes, Alexander; Weiss, Georg; Ustinov, Alexey V.; Lisenfeld, Jürgen

    2017-09-01

    Parasitic two-level tunneling systems (TLS) emerge in amorphous dielectrics and constitute a serious nuisance for various microfabricated devices, where they act as a source of noise and decoherence. Here, we demonstrate a new test bed for the study of TLS in various materials which provides access to properties of individual TLS as well as their ensemble response. We terminate a superconducting transmission-line resonator with a capacitor that hosts TLS in its dielectric. By tuning TLS via applied mechanical strain, we observe the signatures of individual TLS strongly coupled to the resonator in its transmission characteristics and extract the coupling components of their dipole moments and energy relaxation rates. The strong and well-defined coupling to the TLS bath results in pronounced resonator frequency fluctuations and excess phase noise, through which we can study TLS ensemble effects such as spectral diffusion, and probe theoretical models of TLS interactions.

  8. Transition from isolated to overlapping resonances in the open system of interacting fermions

    International Nuclear Information System (INIS)

    Celardo, G.L.; Izrailev, F.M.; Zelevinsky, V.G.; Berman, G.P.

    2008-01-01

    We study the statistical properties of resonance widths and spacings in an open system of interacting fermions. At the transition between isolated and overlapping resonances, a radical change in the width distribution occurs with segregation of broad ('super-radiant') and narrow ('trapped') states. Our main interest is to reveal how this transition is influenced by the onset of chaos in the internal dynamics regulated by the strength of random two-body interaction. In the transitional region, the width distribution and its variance, as well as the distribution of spacings between resonances are strongly affected by internal chaos. The results may be applied to the analysis of neutron cross sections, as well as in the physics of mesoscopic devices with strongly interacting electrons

  9. The Origin of the Non-Additivity in Resonance-Assisted Hydrogen Bond Systems.

    Science.gov (United States)

    Lin, Xuhui; Zhang, Huaiyu; Jiang, Xiaoyu; Wu, Wei; Mo, Yirong

    2017-11-09

    The concept of resonance-assisted hydrogen bond (RAHB) has been widely accepted, and its impact on structures and energetics can be best studied computationally using the block-localized wave function (BLW) method, which is a variant of ab initio valence bond (VB) theory and able to derive strictly electron-localized structures self-consistently. In this work, we use the BLW method to examine a few molecules that result from the merging of two malonaldehyde molecules. As each of these molecules contains two hydrogen bonds, these intramolecular hydrogen bonds may be cooperative or anticooperative, depended on their relative orientations, and compared with the hydrogen bond in malonaldehyde. Apart from quantitatively confirming the concept of RAHB, the comparison of the computations with and without π resonance shows that both σ-framework and π-resonance contribute to the nonadditivity in these RAHB systems with multiple hydrogen bonds.

  10. Blade System Design Study. Part II, final project report (GEC).

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Dayton A. (DNV Global Energy Concepts Inc., Seattle, WA)

    2009-05-01

    As part of the U.S. Department of Energy's Low Wind Speed Turbine program, Global Energy Concepts LLC (GEC)1 has studied alternative composite materials for wind turbine blades in the multi-megawatt size range. This work in one of the Blade System Design Studies (BSDS) funded through Sandia National Laboratories. The BSDS program was conducted in two phases. In the Part I BSDS, GEC assessed candidate innovations in composite materials, manufacturing processes, and structural configurations. GEC also made recommendations for testing composite coupons, details, assemblies, and blade substructures to be carried out in the Part II study (BSDS-II). The BSDS-II contract period began in May 2003, and testing was initiated in June 2004. The current report summarizes the results from the BSDS-II test program. Composite materials evaluated include carbon fiber in both pre-impregnated and vacuum-assisted resin transfer molding (VARTM) forms. Initial thin-coupon static testing included a wide range of parameters, including variation in manufacturer, fiber tow size, fabric architecture, and resin type. A smaller set of these materials and process types was also evaluated in thin-coupon fatigue testing, and in ply-drop and ply-transition panels. The majority of materials used epoxy resin, with vinyl ester (VE) resin also used for selected cases. Late in the project, testing of unidirectional fiberglass was added to provide an updated baseline against which to evaluate the carbon material performance. Numerous unidirectional carbon fabrics were considered for evaluation with VARTM infusion. All but one fabric style considered suffered either from poor infusibility or waviness of fibers combined with poor compaction. The exception was a triaxial carbon-fiberglass fabric produced by SAERTEX. This fabric became the primary choice for infused articles throughout the test program. The generally positive results obtained in this program for the SAERTEX material have led to its

  11. Automated System for Control of the Vacuum Diagnostic System for the TJ-II; Control Automatico de los Sistemas de Vacio de Diagnosticos del Dispositivos TJ-II

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Sanchez, A.; Montoro Peinado, A.; Encabo Fernandez, J.; Gama de la Serrano, J.; Sanchez Sarabia, E. [Ciemat, Madrid (Spain)

    2000-07-01

    This report describes the monitorization and remote control systems belonging to the high vacuum systems of the TJ-II diagnostics. These systems are part of each diagnostic and their control has been integrated into the automata that carries out this task. All the controllers are connected through a Profibus network, so as to interchange data between themselves as well as between the general system of TJ-II. (Author)

  12. Resonant voltage surges in power transmission systems; Sobretensiones resonantes en sistemas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Fuentes Rosado, Jesus

    1988-07-01

    The electric power transmission systems are frequently designed with several transmission lines on the same tower or in the right of way; all this justified mainly for economic or environmental reasons. The transmission power lines generally acquire substantial lengths, of several hundreds of kilometers. The capacitive effect of the transmission power lines, particularly when they are long and are with low power flow, causes high voltages and it is necessary to install reactors in derivation to be able to control the voltages within reasonable values ({+-} 5% of its nominal value). The risk exists, nevertheless, that the electrical circuit formed by the power lines and reactors presents resonance. In case of existing resonance between the capacitive effect of the power line and the inductive effect of the reactor, abnormally high voltages or current circulation of zero sequence appear that could cause damages to reactors, lightning arresters and circuit breakers; multiple reports exist on this type of incidents. It is then necessary, that the planners of electrical power systems prevent the capacity and the characteristics of the reactors for each particular application. In this thesis the equations that allow to determine the values of the reactors capacity for which there would be resonance, are developed. Results for three forms of modeling the transmission power lines are presented and compared: (i) By means of distributed parameters, (ii) By means of concentrated parameters and (iii) Considering solely the capacitive effect of the power lines, denominated electrostatic method. The differences for the problem under study between transposed and not transposed lines are discussed in detail. Also the effect of the different types of reactors; core and armor, single-phase as well as three-phase is discussed, in a similar form, the transformers are studied. The analytical developments are integrated in a digital computer program that allows to analyze the different

  13. The design of photoelectric signal processing system for a nuclear magnetic resonance gyroscope based on FPGA

    Science.gov (United States)

    Zhang, Xian; Zhou, Binquan; Li, Hong; Zhao, Xinghua; Mu, Weiwei; Wu, Wenfeng

    2017-10-01

    Navigation technology is crucial to the national defense and military, which can realize the measurement of orientation, positioning, attitude and speed for moving object. Inertial navigation is not only autonomous, real-time, continuous, hidden, undisturbed but also no time-limited and environment-limited. The gyroscope is the core component of the inertial navigation system, whose precision and size are the bottleneck of the performance. However, nuclear magnetic resonance gyroscope is characteristic of the advantage of high precision and small size. Nuclear magnetic resonance gyroscope can meet the urgent needs of high-tech weapons and equipment development of new generation. This paper mainly designs a set of photoelectric signal processing system for nuclear magnetic resonance gyroscope based on FPGA, which process and control the information of detecting laser .The photoelectric signal with high frequency carrier is demodulated by in-phase and quadrature demodulation method. Finally, the processing system of photoelectric signal can compensate the residual magnetism of the shielding barrel and provide the information of nuclear magnetic resonance gyroscope angular velocity.

  14. Progress on PEP-II magnet power conversion system

    Energy Technology Data Exchange (ETDEWEB)

    Bellomo, P.; Genova, L. [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Jackson, T. [Lawrence Berkeley National Lab., CA (United States); Shimer, D. [Lawrence Livermore National Lab., CA (United States)

    1996-06-04

    The various power systems for supplying the PEP-II DC magnets rely exclusively on switchmode conversion, utilizing a variety of means depending on the requirements. All of the larger power supplies, ranging from 10 to 200 kW, are powered from DC sources utilizing rectified 480 V AC. Choppers can be used for the series connected strings, but for smaller groups and individual magnets, inverters driving high-frequency transformers with rectifiers comprise the best approach. All of the various systems use a ``building block`` approach of multiple standard-size units connected in series or parallel to most cost-effectively deal with a great range of voltage and current requirements. Utilization of existing infrastructure from PEP-I has been a cost-effective determinant. Equipment is being purchased either off-the-shelf, through performance specification, or by hardware purchase based on design-through-prototype. The corrector magnet power system, utilizing inexpensive, off-the-shelf, four-quadrant switching motor-controllers, has already proven very reliable: 120 of the total of 900 units have been running on the injection system for four months with no failures.

  15. Analysis of Middle Frequency Resonance in DFIG System Considering Phase Locked Loop

    DEFF Research Database (Denmark)

    Song, Yipeng; Blaabjerg, Frede

    2018-01-01

    compensated weak network. Besides these two resonances, a Middle Frequency Resonance (MFR) between 200 Hz and 800 Hz may appear when the Phase Locked Loop (PLL) with fast control dynamics is applied. In order to analyze the MFR, the DFIG system impedance considering the PLL is studied based on the Vector...... Oriented Control (VOC) strategy in Rotor Side Converter (RSC) and Grid Side Converter (GSC). On the basis of the established impedance modeling of the DFIG system, it is found that the PLL with fast control dynamics may result in the occurrence of MFR due to a decreasing phase margin. The simulation...... results of both a 7.5 kW small scale DFIG system and a 2 MW large scale DFIG system are provided to validate the theoretical analysis of the MFR....

  16. Analysis and Active Damping of Multiple High Frequency Resonances in DFIG System

    DEFF Research Database (Denmark)

    Song, Yipeng; Blaabjerg, Frede; Wang, Xiongfei

    2017-01-01

    As the wind power generation develops, the Doubly Fed Induction Generator (DFIG) based wind power system are more and more likely to operate in the emerging weak network rather than the conventional stiff network. Due to the comparatively large impedance of the weak network than the stiff grid......, the DFIG system may be subject to the resonances due to the impedance interaction between the DFIG system and the weak network. Especially, when connected to a series π sections weak network, the Multiple High Frequency Resonances (MHFR) may occur and require careful studies. The impedance modeling...... of the DFIG system and the series π sections weak network is firstly demonstrated in this paper. Then, due to the multiple magnitude peaks of the series π sections of the weak network, the MHFR will be produced and can be theoretically explained based on the impedance modeling results. For the purpose...

  17. WASTES II: Waste System Transportation and Economic Simulation. Version II. User's guide

    International Nuclear Information System (INIS)

    Shay, M.R.; Buxbaum, M.E.

    1986-02-01

    The WASTES II model was developed to provide detailed analyses beyond the capabilities of other available models. WASTES uses discrete event simulation techniques to model the generation of commercial spent nuclear fuel, the buildup of spent fuel inventories within the system, and the transportation requirements for the movement of radioactive waste throughout the system. The model is written in FORTRAN 77 as an extension to the SLAM commercial simulation language package. In addition to the pool storage and dry storage located at the reactors, the WASTES model provides a choice of up to ten other storage facilities of four different types. The simulation performed by WASTES may be controlled by a combination of source- and/or destination-controlled transfers that are requested by the code user. The user supplies shipping cask characteristics for truck or rail shipment casks. As part of the facility description, the user specifies which casks the facility can use. Shipments within the system can be user specified to occur optimally, or proximally. Optimized shipping can be used when exactly two destination facilities of the same facility type are open for receipt of fuel. Optimized shipping selects source/destination pairs so that the total shipping distance or total shipping costs in a given year are minimized when both facilities are fully utilized. Proximity shipping sequentially fills the closest facility to the source according to the shipment priorities without regard for the total annual shipments. This results in sub-optimal routing of waste material but can be used to approximate an optimal shipping strategy when more than two facilities of the same type are available to receive waste. WASTES is currently able to analyze each of the commercial spent fuel logistics scenarios specified in the 1985 DOE Mission Plan

  18. EASY-II Renaissance: n, p, d, α, γ-induced Inventory Code System

    Science.gov (United States)

    Sublet, J.-Ch.; Eastwood, J. W.; Morgan, J. G.

    2014-04-01

    The European Activation SYstem has been re-engineered and re-written in modern programming languages so as to answer today's and tomorrow's needs in terms of activation, transmutation, depletion, decay and processing of radioactive materials. The new FISPACT-II inventory code development project has allowed us to embed many more features in terms of energy range: up to GeV; incident particles: alpha, gamma, proton, deuteron and neutron; and neutron physics: self-shielding effects, temperature dependence and covariance, so as to cover all anticipated application needs: nuclear fission and fusion, accelerator physics, isotope production, stockpile and fuel cycle stewardship, materials characterization and life, and storage cycle management. In parallel, the maturity of modern, truly general purpose libraries encompassing thousands of target isotopes such as TENDL-2012, the evolution of the ENDF-6 format and the capabilities of the latest generation of processing codes PREPRO, NJOY and CALENDF have allowed the activation code to be fed with more robust, complete and appropriate data: cross sections with covariance, probability tables in the resonance ranges, kerma, dpa, gas and radionuclide production and 24 decay types. All such data for the five most important incident particles (n, p, d, α, γ), are placed in evaluated data files up to an incident energy of 200 MeV. The resulting code system, EASY-II is designed as a functional replacement for the previous European Activation System, EASY-2010. It includes many new features and enhancements, but also benefits already from the feedback from extensive validation and verification activities performed with its predecessor.

  19. Nonlinear resonances

    CERN Document Server

    Rajasekar, Shanmuganathan

    2016-01-01

    This introductory text presents the basic aspects and most important features of various types of resonances and anti-resonances in dynamical systems. In particular, for each resonance, it covers the theoretical concepts, illustrates them with case studies, and reviews the available information on mechanisms, characterization, numerical simulations, experimental realizations, possible quantum analogues, applications and significant advances made over the years. Resonances are one of the most fundamental phenomena exhibited by nonlinear systems and refer to specific realizations of maximum response of a system due to the ability of that system to store and transfer energy received from an external forcing source. Resonances are of particular importance in physical, engineering and biological systems - they can prove to be advantageous in many applications, while leading to instability and even disasters in others. The book is self-contained, providing the details of mathematical derivations and techniques invo...

  20. Resonant state expansion applied to three-dimensional open optical systems

    OpenAIRE

    Doost, M. B.; Langbein, W.; Muljarov, E. A.

    2014-01-01

    The resonant-state expansion (RSE), a rigorous perturbative method in electrodynamics, is developed for three-dimensional open optical systems. Results are presented using the analytically solvable homogeneous dielectric sphere as unperturbed system. Since any perturbation which breaks the spherical symmetry mixes transverse electric (TE) and transverse magnetic (TM) modes, the RSE is extended here to include TM modes and a zero-frequency pole of the Green's function. We demonstrate the valid...

  1. Analysis and Design of CLL Resonant Converter for Solar Panel-battery Systems

    OpenAIRE

    D.Ramasubramanian; C.Nagarajan; M.Muruganandam

    2012-01-01

    This paper presents a CLL resonant converter with DSP based Fuzzy Logic Controller (FLC) for solar panel to battery charging system. The mathematical model of the converters has been developed and simulated using MATLAB. The state space model of the converter is developed; it is used to analysis the steady state stability of the system. The aim of the proposed converter is to regulate and control of the output voltage from the solar panel voltage. The performance of the proposed converter is ...

  2. System modeling of spent fuel transfers at EBR-II

    International Nuclear Information System (INIS)

    Imel, G.R.; Houshyar, A.

    1994-01-01

    The unloading of spent fuel from the Experimental Breeder Reactor-II (EBR-II) for interim storage and subsequent processing in the Fuel Cycle Facility (FCF) is a multi-stage process, involving complex operations at a minimum of four different facilities at the Argonne National Laboratory-West (ANL-W) site. Each stage typically has complicated handling and/or cooling equipment that must be periodically maintained, leading to both planned and unplanned downtime. A program was initiated in October, 1993 to replace the 330 depleted uranium blanket subassemblies (S/As) with stainless steel reflectors. Routine operation of the reactor for fuels performance and materials testing occurred simultaneously in FY 1994 with the blanket unloading. In the summer of 1994, Congress dictated the October 1, 1994 shutdown of EBR-2. Consequently, all blanket S/As and fueled drivers will be removed from the reactor tank and replaced with stainless steel assemblies (which are needed to maintain a precise configuration within the grid so that the under sodium fuel handling equipment can function). A system modeling effort was conducted to determine the means to achieve the objective for the blanket and fuel unloading program, which under the current plan requires complete unloading of the primary tank of all fueled assemblies in 2 1/2 years. A simulation model of the fuel handling system at ANL-W was developed and used to analyze different unloading scenarios; the model has provided valuable information about required resources and modifications to equipment and procedures. This paper reports the results of this modeling effort

  3. Characterization of Monomeric MnII/III/IV–Hydroxo Complexes from X- and Q-Band Dual Mode Electron Paramagnetic Resonance (EPR) Spectroscopy

    OpenAIRE

    Gupta, Rupal; Taguchi, Taketo; Borovik, A. S.; Hendrich, Michael P.

    2013-01-01

    Manganese–hydroxo species have been implicated in C–H bond activation performed by metalloenzymes, but the electronic properties of many of these intermediates are not well characterized. The present work presents a detailed characterization of three Mnn–OH complexes (where n = II, III, and IV) of the tris[(N′-tert-butylureaylato)-N-ethylene]aminato ([H3buea]3−) ligand using X- and Q-band dual mode electron paramagnetic resonance (EPR). Quantitative simulations for the [MnIIH3buea(OH)]2− comp...

  4. Nonequilibrium steady states and resonant tunneling in time-periodically driven systems with interactions

    Science.gov (United States)

    Qin, Tao; Hofstetter, Walter

    2018-03-01

    Time-periodically driven systems are a versatile toolbox for realizing interesting effective Hamiltonians. Heating, caused by excitations to high-energy states, is a challenge for experiments. While most setups so far address the relatively weakly interacting regime, it is of general interest to study heating in strongly correlated systems. Using Floquet dynamical mean-field theory, we study nonequilibrium steady states (NESS) in the Falicov-Kimball model, with time-periodically driven kinetic energy or interaction. We systematically investigate the nonequilibrium properties of the NESS. For a driven kinetic energy, we show that resonant tunneling, where the interaction is an integer multiple of the driving frequency, plays an important role in the heating. In the strongly correlated regime, we show that this can be well understood using Fermi's golden rule and the Schrieffer-Wolff transformation for a time-periodically driven system. We furthermore demonstrate that resonant tunneling can be used to control the population of Floquet states to achieve "photodoping." For driven interactions introduced by an oscillating magnetic field near a widely adopted Feshbach resonance, we find that the double occupancy is strongly modulated. Our calculations apply to shaken ultracold-atom systems and to solid-state systems in a spatially uniform but time-dependent electric field. They are also closely related to lattice modulation spectroscopy. Our calculations are helpful to understand the latest experiments on strongly correlated Floquet systems.

  5. HIGHER MODE FREQUENCY EFFECTS ON RESONANCE IN MACHINERY, STRUCTURES, AND PIPE SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R.

    2010-05-02

    The complexities of resonance in multi-degree of freedom systems (multi-DOF) may be clarified using graphic presentations. Multi-DOF systems represent actual systems, such as beams or springs, where multiple, higher order, natural frequencies occur. Resonance occurs when a cyclic load is applied to a structure, and the frequency of the applied load equals one of the natural frequencies. Both equations and graphic presentations are available in the literature for single degree of freedom (SDOF) systems, which describe the response of spring-mass-damper systems to harmonically applied, or cyclic, loads. Loads may be forces, moments, or forced displacements applied to one end of a structure. Multi-DOF systems are typically described only by equations in the literature, and while equations certainly permit a case by case analysis for specific conditions, graphs provide an overall comprehension not gleaned from single equations. In fact, this collection of graphed equations provides novel results, which describe the interactions between multiple natural frequencies, as well as a comprehensive description of increased vibrations near resonance.

  6. Dielectric micro-resonator-based opto-mechanical systems for sensing applications

    Science.gov (United States)

    Ali, Amir Roushdy

    In recent years, whispering gallery mode (WGM), or morphology dependent optical resonances (MDR) of dielectric micro-resonators have attracted interest with proposed applications in a wide range of areas due to the high optical quality factors, Q, they can exhibit (reaching ~ 10. 9 for silica spheres). Micro-resonator WGMs have been used in applications that include those in spectroscopy, micro-cavity laser technology, optical communications (switching, filtering and multiplexing), sensors technologies and even chemical and biological sensing. The WGM of these dielectric micro-resonators are highly sensitive to morphological changes (such as the size, shape, or refractive index) of the resonance cavity and hence, can be tuned by causing a minute change in the physical condition of the surrounding. In this dissertation, we have been creating opto-mechanical systems, which at their most basic, are extraordinarily sensitive sensors. One of the ultimate goals of this dissertation is to develop sensors capable of detecting the extremely small electric field changes. To improve the performance of the sensors, we couple a polymer cantilever beam to a dielectric micro-resonator. The eventual use of such ultra sensitive electric filed sensors could include neural-machine interfaces for advanced prosthetics devices. The work presented here includes a basic analysis and experimental investigations of the electric field sensitivity and range of micro-resonators of several different materials and geometries followed by the electric field sensor design, testing, and characterization. Also, the effects of angular velocity on the WGM shifts of spherical micro-resonators are also investigated. The elastic deformation that is induced on a spinning resonator due to the centrifugal force may lead to a sufficient shift in the optical resonances and therefore interfering with its desirable operational sensor design. Furthermore, this principle could be used for the development of

  7. Investigation of coherent molecular resonances in quantum dot–metallic nanoparticle systems using their spontaneous emission

    International Nuclear Information System (INIS)

    Sadeghi, S.M.; Patty, K.D.

    2014-01-01

    In the presence of metallic nanoparticles the nature of the optical excitations (pumping) of semiconductor quantum dots can be determined by their molecular states and resonances formed via coherent coupling of excitons and plasmons. We show that the spontaneous emission of such quantum dots can provide key information regarding formation and characteristics of such molecular properties. This includes an ultra-fast switching process associated with optical transition between the molecular states of the quantum dot-metallic nanoparticle system or its plasmonic meta-resonance when the intensity of the laser field responsible for the exciton–plasmon coupling reaches a critical value. We also show that by varying the intensity of this laser, the spontaneous emission exhibits characteristic features indicating tunability of the molecular resonances and excitation-power dependence of plasmonic fields of the metallic nanoparticles. - Highlights: • Investigation of collective molecular properties of quantum dot-metallic nanoparticle systems. • Impact of such collective properties on the optical excitation of quantum dots. • Effects of exciton–plasmon coupling in the spontaneous emission of the quantum dots. • Signatures of plasmonic meta-resonances in the fluorescence of quantum dots

  8. Operational upgrades to the DIII-D 60 GHz electron cyclotron resonant heating system

    International Nuclear Information System (INIS)

    Harris, T.E.; Cary, W.P.

    1993-10-01

    One of the primary components of the DIII-D radio frequency (rf) program over the past seven years has been the 60 GHz electron cyclotron resonant heating (ECRH) system. The system now consists of eight units capable of operating and controlling eight Varian VGE-8006 60 GHz, 200 kW gyrotrons along with their associated waveguide components. This paper will discuss the operational upgrades and the overall system performance. Many modifications were instituted to enhance the system operation and performance. Modifications discussed in this paper include an improved gyrotron tube-fault response network, a computer controlled pulse-timing and sequencing system, and an improved high-voltage power supply control interface. The discussion on overall system performance will include operating techniques used to improve system operations and reliability. The techniques discussed apply to system start-up procedures, operating the system in a conditioning mode, and operating the system during DIII-D plasma operations

  9. Comparison Between the Trajectories of Electric Field Resonances and those of Rational Surfaces in TJ-II

    International Nuclear Information System (INIS)

    Guasp, J.; Liniers, M.

    2000-01-01

    Both the radial electric field resonance case and the corresponding to rational magnetic surfaces, show a number of similar behaviours: a) Strong sensitivity of the passing particle loss fraction, and mainly of their los times, to lower order rational values of the ratio between the poloidal and toroidal rotation angular velocities. b) In both cases there exist similar simple analytical models that allow qualitative predictions for the phase space regions where resonant effects can be expected. c) Strong similitude of trajectories, as well in the Poincare diagrams as in the angular maps. Near the resonant regions a extreme minimization of the radial excursion appears, and both diagrams present a minimum filling. At both sides of these regions there are wide excursions, directed alternatively towards the inner and the outer parts of the plasma. Far from these resonant zones the diagrams filling comes back to be continuous. d) All these behaviours are more marked, and the topology change more sudden, the lower is the periodicity order of the resonance, and are extremely clear for the 1/3 and 1/2 cases. This wealth of similar behaviour suggests a single origin for all these phenomena, linked with the trajectory topology, that will be the subject of a specific study. (Author) 13 refs

  10. EXAMINING A SERIES RESONANT INVERTER CIRCUIT TO USE IN THE PHOTOVOLTAIC ENERGY CONVERSION SYSTEMS

    Directory of Open Access Journals (Sweden)

    Engin ÇETİN

    2004-03-01

    Full Text Available As we know, solar energy is the energy source which is environment friendly, renewable, and can be found easily. Particularly, in the recent years, interest on producing electrical energy by alternative energy sources increased because of the fact that underground sources are not enough to produce energy in the future and also these sources cause enviromental pollution. The solar energy is one of the most popular one among the alternative energy sources. Photovoltaic systems produce the electrical energy from the sunlight. In this study, a series resonant inverter circuit which is used in the photovoltaic energy conversion systems has been examined.Effects of the series resonant inverter circuit on the photovoltaic energy conversion system have been investigated and examined

  11. Resonance production in high energy collisions from small to big systems

    Science.gov (United States)

    Werner, K.; Knospe, A. G.; Markert, C.; Guiot, B.; Karpenko, Iu.; Pierog, T.; Sophys, G.; Stefaniak, M.; Bleicher, M.; Steinheimer, J.

    2018-02-01

    The aim of this paper is to understand resonance production (and more generally particle production) for different collision systems, namely proton-proton (pp), proton-nucleus (pA), and nucleus-nucleus (AA) scattering at the LHC. We will investigate in particular particle yields and ratios versus multiplicity, using the same multiplicity definition for the three different systems, in order to analyse in a compact way the evolution of particle production with the system size and the origin of a very different system size dependence of the different particles.

  12. Computer-Aided Diagnosis Systems for Brain Diseases in Magnetic Resonance Images

    Directory of Open Access Journals (Sweden)

    Yasuo Yamashita

    2009-07-01

    Full Text Available This paper reviews the basics and recent researches of computer-aided diagnosis (CAD systems for assisting neuroradiologists in detection of brain diseases, e.g., asymptomatic unruptured aneurysms, Alzheimer's disease, vascular dementia, and multiple sclerosis (MS, in magnetic resonance (MR images. The CAD systems consist of image feature extraction based on image processing techniques and machine learning classifiers such as linear discriminant analysis, artificial neural networks, and support vector machines. We introduce useful examples of the CAD systems in the neuroradiology, and conclude with possibilities in the future of the CAD systems for brain diseases in MR images.

  13. Data acquisition system for electron cyclotron resonance heating on EAST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Weiye, E-mail: xuweiye@ipp.cas.cn; Xu, Handong, E-mail: xhd@ipp.cas.cn; Liu, Fukun; Hou, Fang; Wu, Zege

    2016-12-15

    Highlights: • A steady-state data acquisition system for ECRH on EAST tokamak is developed. • Both hardware architecture and software architecture are described. • The data acquisition system is very important for gyrotron operation. - Abstract: A steady-state data acquisition system for electron cyclotron resonance heating on EAST tokamak is presented. This system is established to acquire gyrotron related signals based on PXI platform. The acquired signals are used to analyze the state of gyrotrons, and to calculate the RF power generated by gyrotrons. The acquired data are saved to the data storage server and can be recalled by the data view client.

  14. Förster resonance energy transfer, absorption and emission spectra in multichromophoric systems. I. Full cumulant expansions and system-bath entanglement.

    Science.gov (United States)

    Ma, Jian; Cao, Jianshu

    2015-03-07

    We study the Förster resonant energy transfer rate, absorption and emission spectra in multichromophoric systems. The multichromophoric Förster theory (MCFT) is determined from an overlap integral of generalized matrices related to the donor's emission and acceptor's absorption spectra, which are obtained via a full 2nd-order cumulant expansion technique developed in this work. We calculate the spectra and MCFT rate for both localized and delocalized systems, and calibrate the analytical 2nd-order cumulant expansion with the exact stochastic path integral method. We present three essential findings: (i) The role of the initial entanglement between the donor and its bath is found to be crucial in both the emission spectrum and the MCFT rate. (ii) The absorption spectra obtained by the cumulant expansion method are nearly identical to the exact spectra for both localized and delocalized systems, even when the system-bath coupling is far from the perturbative regime. (iii) For the emission spectra, the cumulant expansion can give reliable results for localized systems, but fail to provide reliable spectra of the high-lying excited states of a delocalized system, when the system-bath coupling is large and the thermal energy is small. This paper also provides a simple golden-rule derivation of the MCFT, reviews existing methods, and motivates further developments in the subsequent papers.

  15. The galenic venous system: Surgical anatomy and its angiographic and magnetic resonance venographic correlations

    International Nuclear Information System (INIS)

    Kilic, Tuerker; Ozduman, Koray; Cavdar, Safiye; Oezek, M. Memet; Pamir, M. Necmettin

    2005-01-01

    Objective: This study aims at evaluating the adequacy of digital subtraction angiography and magnetic resonance venography in imaging of the galenic venous system for surgical planning of approaches to the pineal region. Anatomical dissections were carried out in 10 cadavers of several age groups and these were compared to imaging findings in 10 living subjects. Methods: The presence or absence of 10 predetermined veins or vein groupings belonging to the galenic venous system were prospectively analyzed in 10 cadaver dissections and imaging findings of 10 age matched human subjects. The studied vessels were the vein of galen, the internal cerebral veins, both basal vein of Rosenthals, internal occipital vein, occipitotemporal veins, precentral cerebellar veins, tectal veins, pineal veins, superior vermian veins (including superior cerebellar veins (SCVs)) and posterior pericallosal veins. Each of the subjects had both digital subtraction angiography and magnetic resonance venography studies performed. Diagnostic digital subtraction angiography was performed using the transfemoral route and the venous phase was used for the study. Magnetic resonance venography was performed in 1.5 T MRI equipment using the 2D-TOF sequence. All studies were reported to be normal. Results: There was wide variation in the anatomy of the galenic venous system. There were interpersonal, intrapersonal and age related variations. Both the digital subtraction angiography and the magnetic resonance venography were efficient at demonstrating large veins. However, smaller veins were less readily demonstrated in either study. The general sensitivities of the digital subtraction angiography and the magnetic resonance venography for the galenic venous system were 45.5% and 32.5%, respectively. Surgically important veins were missed in most studies. Conclusions: Anatomically, the galenic venous system is highly variable. This variability is caused by interpersonal, intrapersonal and age related

  16. Nonterminals, homomorphisms and codings in different variations of OL-systems. II. Nondeterministic systems

    DEFF Research Database (Denmark)

    Nielsen, Mogens; Rozenberg, Grzegorz; Salomaa, Arto

    1974-01-01

    Continuing the work begun in Part I of this paper, we consider now variations of nondeterministic OL-systems. The present Part II of the paper contains a systematic classification of the effect of nonterminals, codings, weak codings, nonerasing homomorphisms and homomorphisms for all basic variat...

  17. Ultraviolet high-excitation Fe II fluorescence lines excited by O VI, C IV, and H I resonance emission as seen in IUE spectra

    International Nuclear Information System (INIS)

    Feibelman, W.A.; Bruhweiler, F.C.; Johansson, S.

    1991-01-01

    Archival high-dispersion spectra from the IUE are used in a search for Bowen emission lines of Fe II excited by the stronger transition of the O VI resonance doublet. The possibility of using these Fe II emission lines as a diagnostic of the strength of the far-ultraviolet emission of O VI at 1032 A is explored. It is found that the Fe II emission lines are quite common and strong in symbiotic stars, particularly those of the type known as 'symbiotic novae', as well as in normal novae. The lines are observed in central stars of some planetary nebulae of the O VI sequence besides a few central stars of type WR. High density, high excitation, and high temperature are suggested to be requirements for the excitation of the Fe II fluorescence lines. It is pointed out that while these lines were observed in PG 1159-035 and K1-16, they were not observed in AGNs. 22 refs

  18. Design and optimization of a 3-coil resonance-based wireless power transfer system for biomedical implants

    KAUST Repository

    Yi, Ying

    2014-09-01

    This paper presents a resonance-based wireless power transfer system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. We theoretically analyzed the system and characterized it by measuring its inductance, self-resonant frequency, and quality factor Q. In our resonance-based wireless power transfer prototype, we proposed a 3-coil system, using two 15-mm radius implantable coils, with a resonance frequency of 6.76MHz. This system can effectively transfer power for a distance of up to 50mm. Moreover, our proposed 3-coil system can achieve a high Q-factor and has a comparable power transfer efficiency (PTE) to previously reported works about 3-coil and 4-coil systems. The experimental PTE can achieve 82.4% at a separation distance of 20mm and more than 10% PTE at a distance of 40mm.

  19. Interaction of Zn(II) with hematite nanoparticles and microparticles: Part 2. ATR-FTIR and EXAFS study of the aqueous Zn(II)/oxalate/hematite ternary system.

    Science.gov (United States)

    Ha, Juyoung; Trainor, Thomas P; Farges, François; Brown, Gordon E

    2009-05-19

    Sorption of Zn(II) to hematite nanoparticles (HN) (av diam=10.5 nm) and microparticles (HM) (av diam=550 nm) was studied in the presence of oxalate anions (Ox2-(aq)) in aqueous solutions as a function of total Zn(II)(aq) to total Ox2-(aq) concentration ratio (R=[Zn(II)(aq)]tot/[Ox2-(aq)]tot) at pH 5.5. Zn(II) uptake is similar in extent for both the Zn(II)/Ox/HN and Zn(II)/Ox/HM ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)](tot)system than for the Zn(II)/Ox/HM ternary and the Zn(II)/HN and Zn(II)/HM binary systems at [Zn(II)(aq)]tot>4 mM. In contrast, Zn(II) uptake for the Zn(II)/HM binary system is a factor of 2 greater than that for the Zn(II)/Ox/HM and Zn(II)/Ox/HN ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)]totternary system at both R values examined (0.16 and 0.68), attenuated total reflectance Fourier transform infrared (ATR-FTIR) results are consistent with the presence of inner-sphere oxalate complexes and outer-sphere ZnOx(aq) complexes, and/or type A ternary complexes. In addition, extended X-ray absorption fine structure (EXAFS) spectroscopic results suggest that type A ternary surface complexes (i.e., >O2-Zn-Ox) are present. In the Zn(II)/Ox/HN ternary system at R=0.15, ATR-FTIR results indicate the presence of inner-sphere oxalate and outer-sphere ZnOx(aq) complexes; the EXAFS results provide no evidence for inner-sphere Zn(II) complexes or type A ternary complexes. In contrast, ATR-FTIR results for the Zn/Ox/HN sample with R = 0.68 are consistent with a ZnOx(s)-like surface precipitate and possibly type B ternary surface complexes (i.e., >O2-Ox-Zn). EXAFS results are also consistent with the presence of ZnOx(s)-like precipitates. We ascribe the observed increase of Zn(II)(aq) uptake in the Zn(II)/Ox/HN ternary system at [Zn(II)(aq)]tot>or=4 mM relative to the Zn(II)/Ox/HM ternary system to formation of a ZnOx(s)-like precipitate at the hematite nanoparticle/water interface.

  20. Packets of resonant modes in the Fermi–Pasta–Ulam system

    International Nuclear Information System (INIS)

    Genta, Tommaso; Giorgilli, Antonio; Paleari, Simone; Penati, Tiziano

    2012-01-01

    We reconsider the phenomenon of localization of energy in low frequency modes in the FPU system, exploiting the resonances in the lower part of the spectrum. Using the resonant normal form of Birkhoff we construct some candidates of approximate first integrals which we put in correspondence to packets of low frequency modes. By numerical calculation we show that the packet associated to the best quasi-integral involves all modes up to a frequency ω ⁎ (ε), where ε is the specific energy. The phenomenon disappears when the specific energy is bigger than a threshold value. The dependence of the relevant quantities on the number N of particles is also investigated. A final section is devoted to a first comparison with the Toda model. -- Highlights: ► We study the role of resonances for energy localization and metastability in the FPU model. ► We construct an approximated first integral associated to the metastable state. ► We propose to identify the metastable state as a packet of resonant modes. ► The packet extend up to a frequency ω ⁎ (ε), which depends only on the specific energy ε.

  1. Hybrid Active Filter with Variable Conductance for Harmonic Resonance Suppression in Industrial Power Systems

    DEFF Research Database (Denmark)

    Lee, Tzung-Lin; Wang, Yen-Ching; Li, Jian-Cheng

    2015-01-01

    Unintentional series and/or parallel resonances, due to the tuned passive filter and the line inductance, may result in severe harmonic distortion in the industrial power system. This paper presents a hybrid active filter to suppress harmonic resonance and reduce harmonic distortion as well......-tuned passive filter and an active filter in series connection, both dc voltage and kVA rating of the active filter are dramatically decreased compared with the pure shunt active filter. In real application, this feature is very attractive since the active power filter with fully power electronics is very....... The proposed hybrid filter is operated as variable harmonic conductance according to the voltage total harmonic distortion, so harmonic distortion can be reduced to an acceptable level in response to load change or parameter variation of power system. Since the hybrid filter is composed of a seventh...

  2. 3-Coil resonance-based wireless power transfer system for implantable electronic

    KAUST Repository

    Yi, Ying

    2013-05-01

    This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.

  3. Heterogeneous delay-induced asynchrony and resonance in a small-world neuronal network system

    Science.gov (United States)

    Yu, Wen-Ting; Tang, Jun; Ma, Jun; Yang, Xianqing

    2016-06-01

    A neuronal network often involves time delay caused by the finite signal propagation time in a given biological network. This time delay is not a homogenous fluctuation in a biological system. The heterogeneous delay-induced asynchrony and resonance in a noisy small-world neuronal network system are numerically studied in this work by calculating synchronization measure and spike interval distribution. We focus on three different delay conditions: double-values delay, triple-values delay, and Gaussian-distributed delay. Our results show the following: 1) the heterogeneity in delay results in asynchronous firing in the neuronal network, and 2) maximum synchronization could be achieved through resonance given that the delay values are integer or half-integer times of each other.

  4. Identification of Copper(II) Complexes in Aqueous Solution by Electron Spin Resonance: An Undergraduate Coordination Chemistry Experiment.

    Science.gov (United States)

    Micera, G.; And Others

    1984-01-01

    Background, procedures, and results are provided for an experiment which examines, through electron spin resonance spectroscopy, complex species formed by cupric and 2,6-dihydroxybenzoate ions in aqueous solutions. The experiment is illustrative of several aspects of inorganic and coordination chemistry, including the identification of species…

  5. Electronic energy transfer through non-adiabatic vibrational-electronic resonance. II. 1D spectra for a dimer

    Science.gov (United States)

    Tiwari, Vivek; Jonas, David M.

    2018-02-01

    Vibrational-electronic resonance in photosynthetic pigment-protein complexes invalidates Förster's adiabatic framework for interpreting spectra and energy transfer, thus complicating determination of how the surrounding protein affects pigment properties. This paper considers the combined effects of vibrational-electronic resonance and inhomogeneous variations in the electronic excitation energies of pigments at different sites on absorption, emission, circular dichroism, and hole-burning spectra for a non-degenerate homodimer. The non-degenerate homodimer has identical pigments in different sites that generate differences in electronic energies, with parameters loosely based on bacteriochlorophyll a pigments in the Fenna-Matthews-Olson antenna protein. To explain the intensity borrowing, the excited state vibrational-electronic eigenvectors are discussed in terms of the vibrational basis localized on the individual pigments, as well as the correlated/anti-correlated vibrational basis delocalized over both pigments. Compared to those in the isolated pigment, vibrational satellites for the correlated vibration have the same frequency and precisely a factor of 2 intensity reduction through vibrational delocalization in both absorption and emission. Vibrational satellites for anti-correlated vibrations have their relaxed emission intensity reduced by over a factor 2 through vibrational and excitonic delocalization. In absorption, anti-correlated vibrational satellites borrow excitonic intensity but can be broadened away by the combination of vibronic resonance and site inhomogeneity; in parallel, their vibronically resonant excitonic partners are also broadened away. These considerations are consistent with photosynthetic antenna hole-burning spectra, where sharp vibrational and excitonic satellites are absent. Vibrational-excitonic resonance barely alters the inhomogeneously broadened linear absorption, emission, and circular dichroism spectra from those for a

  6. Lithofacies identification using multiple adaptive resonance theory neural networks and group decision expert system

    Science.gov (United States)

    Chang, H.-C.; Kopaska-Merkel, D. C.; Chen, H.-C.; Rocky, Durrans S.

    2000-01-01

    Lithofacies identification supplies qualitative information about rocks. Lithofacies represent rock textures and are important components of hydrocarbon reservoir description. Traditional techniques of lithofacies identification from core data are costly and different geologists may provide different interpretations. In this paper, we present a low-cost intelligent system consisting of three adaptive resonance theory neural networks and a rule-based expert system to consistently and objectively identify lithofacies from well-log data. The input data are altered into different forms representing different perspectives of observation of lithofacies. Each form of input is processed by a different adaptive resonance theory neural network. Among these three adaptive resonance theory neural networks, one neural network processes the raw continuous data, another processes categorial data, and the third processes fuzzy-set data. Outputs from these three networks are then combined by the expert system using fuzzy inference to determine to which facies the input data should be assigned. Rules are prioritized to emphasize the importance of firing order. This new approach combines the learning ability of neural networks, the adaptability of fuzzy logic, and the expertise of geologists to infer facies of the rocks. This approach is applied to the Appleton Field, an oil field located in Escambia County, Alabama. The hybrid intelligence system predicts lithofacies identity from log data with 87.6% accuracy. This prediction is more accurate than those of single adaptive resonance theory networks, 79.3%, 68.0% and 66.0%, using raw, fuzzy-set, and categorical data, respectively, and by an error-backpropagation neural network, 57.3%. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.

  7. Fractal Scaling Models of Resonant Oscillations in Chain Systems of Harmonic Oscillators

    OpenAIRE

    Müller H.

    2009-01-01

    Logarithmic scaling invariance is a wide distributed natural phenomenon and was proved in the distributions of physical properties of various processes — in high en- ergy physics, chemistry, seismicity, biology, geology and technology. Based on the Gantmacher-Krein continued fraction method the present paper introduces fractal scal- ing models of resonant oscillations in chain systems of harmonic oscillators. These models generate logarithmic scaling spect...

  8. Neutron Resonances in Systems of Few Nuclei and Their Possible Role in Radiation of Overdense Stars

    International Nuclear Information System (INIS)

    Takibayev, N. Zh.

    2011-01-01

    Exact analytical solutions of three- and four-body systems made of one light particle and other heavy particles have been obtained in the model of Born-Oppenheimer approximation with two-body separable interactions. In the case of neutron scattering on a subsystem of few fixed nuclei the appearance of new resonance quantum states has been shown as well as their dependence on distances between heavy nuclei. The applications of new phenomena to overdense stars radiation are considered. (author)

  9. Damping characteristic identification of non-linear soil-structural system interaction by phase resonance

    International Nuclear Information System (INIS)

    Poterasu, V.F.

    1984-01-01

    It is presented a method and the phase resonance for damping characteristic identification of non-linear soil-structural interaction. The algorithm can be applied in case of any, not necessarily, damping characteristic of the system examined. For the identification, the system is harmonically excited and are considered the super-harmonic amplitudes for odd and even powers of the x. The response of shear beam system for different levels of base excitation and for different locations of the load is considered. (Author) [pt

  10. Analysis and optimisation of coupled winding in magnetic resonant wireless power transfer systems with orthogonal experiment results

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual ...

  11. Analysis and optimization of coupled windings in magnetic resonant wireless power transfer systems with orthogonal experiment method

    DEFF Research Database (Denmark)

    Yudi, Xiao; Xingkui, Mao; Mao, Lin

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual ...

  12. EBR-II argon cooling system restricted fuel handling I and C upgrade

    International Nuclear Information System (INIS)

    Start, S.E.; Carlson, R.B.; Gehrman, R.L.

    1995-01-01

    The instrumentation and control of the Argon Cooling System (ACS) restricted fuel handling control system at Experimental Breeder Reactor II (EBR-II) is being upgraded from a system comprised of many discrete components and controllers to a computerized system with a graphical user interface (GUI). This paper describes the aspects of the upgrade including reasons for the upgrade, the old control system, upgrade goals, design decisions, philosophies and rationale, and the new control system hardware and software

  13. Value of computed tomography and magnetic resonance imaging in diagnosis of central nervous system

    International Nuclear Information System (INIS)

    Walecka, I.; Sicinska, J.; Szymanska, E.; Rudnicka, L.; Furmanek, M.; Walecki, J.; Olszewska, M.; Rudnicka, L.; Walecki, J.

    2006-01-01

    Systemic sclerosis is an autoimmune connective tissue disease characterized by vascular abnormalities and fibrotic changes in skin and internal organs. The aim of the study was to investigate involvement of the central nervous system in systemic sclerosis and the value of computed tomography (CT) and magnetic resonance imaging (MRI) in evaluation of central nervous system involvement in systemic sclerosis. 26 patients with neuropsychiatric symptoms in the course of systemic sclerosis were investigated for central nervous system abnormalities by computed tomography (CT) and magnetic resonance imaging (MRI). Among these 26 symptomatic patients lesions in brain MRI and CT examinations were present in 54% and in 50% patients respectively. Most common findings (in 46% of all patients), were symptoms of cortical and subcortical atrophy, seen in both, MRI and CT. Single and multiple focal lesions, predominantly in the white matter, were detected by MRI significantly more frequently as compared to CT (62% and 15% patients respectively). These data indicate that brain involvement is common in patients with severe systemic sclerosis. MRI shows significantly higher than CT sensitivity in detection focal brain lesions in these patients. (author)

  14. The systems biology of MHC class II antigen presentation

    NARCIS (Netherlands)

    Paul, Petra

    2012-01-01

    Major histocompatibility class II molecules (MHC class II) are one of the key regulators of adaptive immunity because of their specific expression by professional antigen presenting cells (APC). They present peptides derived from endocytosed material to T helper lymphocytes. Consequently, MHC class

  15. Firing-rate resonances in the peripheral auditory system of the cricket, Gryllus bimaculatus.

    Science.gov (United States)

    Rau, Florian; Clemens, Jan; Naumov, Victor; Hennig, R Matthias; Schreiber, Susanne

    2015-11-01

    In many communication systems, information is encoded in the temporal pattern of signals. For rhythmic signals that carry information in specific frequency bands, a neuronal system may profit from tuning its inherent filtering properties towards a peak sensitivity in the respective frequency range. The cricket Gryllus bimaculatus evaluates acoustic communication signals of both conspecifics and predators. The song signals of conspecifics exhibit a characteristic pulse pattern that contains only a narrow range of modulation frequencies. We examined individual neurons (AN1, AN2, ON1) in the peripheral auditory system of the cricket for tuning towards specific modulation frequencies by assessing their firing-rate resonance. Acoustic stimuli with a swept-frequency envelope allowed an efficient characterization of the cells' modulation transfer functions. Some of the examined cells exhibited tuned band-pass properties. Using simple computational models, we demonstrate how different, cell-intrinsic or network-based mechanisms such as subthreshold resonances, spike-triggered adaptation, as well as an interplay of excitation and inhibition can account for the experimentally observed firing-rate resonances. Therefore, basic neuronal mechanisms that share negative feedback as a common theme may contribute to selectivity in the peripheral auditory pathway of crickets that is designed towards mate recognition and predator avoidance.

  16. Manchester code telemetry system for well logging using quasi-parallel inductive-capacitive resonance

    Science.gov (United States)

    Xu, Lijun; Chen, Jianjun; Cao, Zhang; Liu, Xingbin; Hu, Jinhai

    2014-07-01

    In this paper, a quasi-parallel inductive-capacitive (LC) resonance method is proposed to improve the recovery of MIL-STD-1553 Manchester code with several frequency components from attenuated, distorted, and drifted signal for data telemetry in well logging, and corresponding telemetry system is developed. Required resonant frequency and quality factor are derived, and the quasi-parallel LC resonant circuit is established at the receiving end of the logging cable to suppress the low-pass filtering effect caused by the distributed capacitance of the cable and provide balanced pass for all the three frequency components of the Manchester code. The performance of the method for various encoding frequencies and cable lengths at different bit energy to noise density ratios (Eb/No) have been evaluated in the simulation. A 5 km single-core cable used in on-site well logging and various encoding frequencies were employed to verify the proposed telemetry system in the experiment. Results obtained demonstrate that the telemetry system is feasible and effective to improve the code recovery in terms of anti-attenuation, anti-distortion, and anti-drift performances, decrease the bit error rate, and increase the reachable transmission rate and distance greatly.

  17. Caltrans WeatherShare Phase II System: An Application of Systems and Software Engineering Process to Project Development

    Science.gov (United States)

    2009-08-25

    In cooperation with the California Department of Transportation, Montana State University's Western Transportation Institute has developed the WeatherShare Phase II system by applying Systems Engineering and Software Engineering processes. The system...

  18. Analysis and Comparison of High Frequency Resonance in Small and Large Scale DFIG System

    DEFF Research Database (Denmark)

    Song, Yipeng; Blaabjerg, Frede; Wang, Xiongfei

    2016-01-01

    When connected to a parallel compensated weak grid network, both the small and large power scale Doubly Fed Induction Generator (DFIG) system may suffer high frequency resonance (HFR) due to the impedance interaction between the DFIG system and the parallel compensated weak network. Since...... the parameters of the small and large scale DFIG systems, including DFIG machine parameters and the LCL filter parameters, may vary between 10 to 100 times, the impedance modeling results of small and large scale DFIG system are quite different. Based on the built impedance modeling results, the HFR in small...... and large scale DFIG system are theoretically analyzed and compared in this paper with the discussion on the influence of PI controller proportional parameters and the digital control delay on the DFIG system impedance shaping. The experimental validation of small scale DFIG system and the simulation...

  19. Doubly Fed Induction Generator System Resonance Active Damping through Stator Virtual Impedance

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    (positive capacitor or negative inductor) into the stator branch through stator current feedforward control. The effectiveness of the DFIG system active damping control is verified by a 7.5 kW experimental down-scaled DFIG system, and simulation results of a commercial 2 MW DFIG system is provided as well....... converters/loads. This paper analyzes and explains first the HFR phenomenon between the DFIG system and a parallel compensated weak network (series RL + shunt C). Then on the basis of the DFIG system impedance modeling, an active damping control strategy is introduced by inserting a virtual impedance...... Frequency Resonance (HFR) due to the impedance interaction between the DFIG system and the weak grid network whose impedance is comparative large. Thus, it is important to implement an active damping for the HFR in order to ensure a safe and reliable operation of both the DFIG system and the grid connected...

  20. Multiphoton-resonance-induced fluorescence of a strongly driven two-level system under frequency modulation

    Science.gov (United States)

    Yan, Yiying; Lü, Zhiguo; Luo, JunYan; Zheng, Hang

    2018-03-01

    We study the fluorescence spectrum of a strongly driven two-level system (TLS) with modulated transition frequency, which is a bichromatically driven TLS and has multiple resonance frequencies. We are aiming to provide a reliable description of the fluorescence in a regime that is difficult to tackle with perturbation theory and the rotating-wave approximation (RWA), and illustrate the spectral features of the fluorescence under off- and multiphoton-resonance conditions. To go beyond the RWA, we use a semianalytical counter-rotating-hybridized rotating-wave method that combines a unitary transformation and Floquet theory to calculate the two-mode Floquet states and quasienergies for the bichromatically driven TLS. We then solve the master equation accounting for the spontaneous decay in the bases of the two-mode Floquet states, and derive a physically transparent fluorescence spectrum. In comparison with the numerically exact spectrum from the generalized Floquet-Liouville approach, the present spectrum is found to be applicable in a wide range of the parameters where the RWA and the secular approximation may break down. We find that the counter-rotating (CR) terms of the transverse field omitted in the RWA have non-negligible contributions to the spectrum under certain conditions. Particularly, at the multiphoton resonance the width of which is comparable with the Bloch-Siegert shift, the RWA and non-RWA spectra markedly differ from each other because of the CR-induced shift. We also analyze the symmetry of the spectrum in terms of the transition matrix elements between the two-mode Floquet states. We show that the strict symmetry of the spectrum cannot be expected without the RWA but the almost symmetric spectrum can be obtained at the single-photon resonance that takes the Bloch-Siegert shift into account if the driving is moderately strong and at the multiphoton resonance with a sufficiently weak transverse field.

  1. Solar Electric Generating System II finite element analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dohner, J.L.; Anderson, J.R.

    1994-04-01

    On June 2, 1992, Landers` earthquake struck the Solar Electric Generating System II, located in Daggett, California. The 30 megawatt power station, operated by the Daggett Leasing Corporation (DLC), suffered substantial damage due to structural failures in the solar farm. These failures consisted of the separation of sliding joints supporting a distribution of parabolic glass mirrors. At separation, the mirrors fell to the ground and broke. It was the desire of the DLC and the Solar Thermal Design Assistance Center (STDAC) of Sandia National Laboratories (SNL) and to redesign these joints so that, in the event of future quakes, costly breakage will be avoided. To accomplish this task, drawings of collector components were developed by the STDAC, from which a detailed finite element computer model of a solar collector was produced. This nonlinear dynamic model, which consisted of over 8,560 degrees of freedom, underwent model reduction to form a low order nonlinear dynamic model containing only 40 degrees of freedom. This model was then used as a design tool to estimate joint dynamics. Using this design tool, joint configurations were modified, and an acceptable joint redesign determined. The results of this analysis showed that the implementation of metal stops welded to support shafts for the purpose of preventing joint separation is a suitable joint redesign. Moreover, it was found that, for quakes of Landers` magnitude, mirror breakage due to enhanced vibration in the trough assembly is unlikely.

  2. The Belle II PXD data acquisition and reduction system

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Soeren; Gessler, Thomas; Kuehn, Wolfgang; Muenchow, David; Spruck, Bjoern [Giessen Univ. (Germany). 2. Physikalisches Inst.; Lin, Haichuan; Liu, Zhen-An; Xu, Hao; Zhao, Jingzhou [IHEP Beijing (China); Collaboration: Belle II Collaboration

    2013-07-01

    The Belle II DEPFET pixel detector (PXD) will deliver high data rates of up to 21.6 Gbytes/s for 3% detector occupancy. Data of this high rate must be buffered for 5 seconds, corresponding to the HLT (High Level Trigger) latency, and then a region-of-interest (ROI) filter is applied to reduce the data rate by a factor of ≥10 by charged track extrapolation from other detectors (SVD, CDC). The PXD readout system is based upon ATCA (Advanced Telecommunications Architecture). The 3rd PCB iteration uses a concept with a xTCA carrier board (with a Virtex-4 FX60 FPGA for ATCA backplane routing) and 4 AMC modules (each with a Xilinx Virtex-5 FX70T FPGA). The FPGA firmware implementation comprises a receiver core for the high speed optical links (≤6.25 Gbps), a buffer management with lookup of ≤270.000 pointers/s, DDR2 memory write (native port interface, ≥1.5 Gbytes/s), Gigabit ethernet (UDP stack in VHDL) and a parallelized ROI selection algorithm. Test results of all the components are presented.

  3. The redshift number density evolution of Mg II absorption systems

    International Nuclear Information System (INIS)

    Chen Zhi-Fu

    2013-01-01

    We make use of the recent large sample of 17 042 Mg II absorption systems from Quider et al. to analyze the evolution of the redshift number density. Regardless of the strength of the absorption line, we find that the evolution of the redshift number density can be clearly distinguished into three different phases. In the intermediate redshift epoch (0.6 ≲ z ≲ 1.6), the evolution of the redshift number density is consistent with the non-evolution curve, however, the non-evolution curve over-predicts the values of the redshift number density in the early (z ≲ 0.6) and late (z ≳ 1.6) epochs. Based on the invariant cross-section of the absorber, the lack of evolution in the redshift number density compared to the non-evolution curve implies the galaxy number density does not evolve during the middle epoch. The flat evolution of the redshift number density tends to correspond to a shallow evolution in the galaxy merger rate during the late epoch, and the steep decrease of the redshift number density might be ascribed to the small mass of halos during the early epoch.

  4. Rooftop PV system. Final technical progress report, Phase II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    Under this four-year PV:BONUS Program, ECD and United Solar are developing and demonstrating two new lightweight flexible building integrated Photovoltaic (BIPV) modules specifically designed as exact replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and address the even larger roofing replacement market. The modules are designed to be installed by roofing contractors without special training which minimizes the installation and balance of system costs. The modules will be fabricated from high-efficiency, multiple-junction a-Si alloy solar cells developed by ECD and United Solar. Under the Phase I Program, which ended in March 1994, we developed two different concept designs for rooftop PV modules: (1) the United Solar overlapping (asphalt shingle replacement) shingle-type modules and (2) the ECD metal roof-type modules. We also developed a plan for fabricating, testing and demonstrating these modules. Candidate demonstration sites for our rooftop PV modules were identified and preliminary engineering designs for these demonstrations were developed; a marketing study plan was also developed. The major objectives of the Phase II Program, which started in June 1994 was (1) to develop, test, and qualify these new rooftop modules; (2) to develop mechanical and electrical engineering specifications for the demonstration projects; and (3) to develop a marketing/commercialization plan.

  5. Investigations and system design for simultaneous energy and data transmission through inductively coupled resonances

    Science.gov (United States)

    Schmidt, C.; Lloret Fuentes, E.; Buchholz, M.

    2015-11-01

    Wireless Power Transfer (WPT) with simultaneous data transmission through coupled magnetic resonators is investigated in this paper. The development of this system is dedicated to serve as a basis for applications in the field of Ambient Assisted Living (AAL), for example tracking vital parameters remotely, charge and control sensors and so on. Due to these different scenarios we consider, it is important to have a system which is reliable under the circumstance of changing positioning of the receiving device. State of the art radio systems would be able to handle this. Nevertheless, energy harvesting from far field sources is not sufficient to power the devices additionally on mid-range distances. For this reason, coupled magnetic resonant circuits are proposed as a promising alternative, although suffering from more complex positioning dependency. Based on measurements on a simple prototype system, an equivalent circuit description is used to model the transmission system dependent on different transmission distances and impedance matching conditions. Additionally, the simulation model is used to extract system parameters such as coupling coefficients, coil resistance and self-capacitance, which cannot be calculated in a simple and reliable way. Furthermore, a mathematical channel model based on the schematic model has been built in MATLAB©. It is used to point out the problems occurring in a transmission system with variable transmission distance, especially the change of the passband's centre frequency and its bandwidth. Existing solutions dealing with this distance dependent behaviour, namely the change of the transmission frequency dependent on distance and the addition of losses to the resonators to increase the bandwidth, are considered as not inventive. First, changing the transmission frequency increases the complexity in the data transmission system and would use a disproportional total bandwidth compared to the actually available bandwidth

  6. Characterization and inhibition of norovirus proteases of genogroups I and II using a fluorescence resonance energy transfer assay

    International Nuclear Information System (INIS)

    Chang, Kyeong-Ok; Takahashi, Daisuke; Prakash, Om; Kim, Yunjeong

    2012-01-01

    Noroviruses are the major cause of food- or water-borne gastroenteritis outbreaks in humans. The norovirus protease that cleaves a large viral polyprotein to nonstructural proteins is essential for virus replication and an attractive target for antiviral drug development. Noroviruses show high genetic diversity with at least five genogroups, GI–GV, of which GI and GII are responsible for the majority of norovirus infections in humans. We cloned and expressed proteases of Norwalk virus (GI) and MD145 virus (GII) and characterized the enzymatic activities with fluorescence resonance energy transfer substrates. We demonstrated that the GI and GII proteases cleaved the substrates derived from the naturally occurring cleavage site in the open reading frame (ORF) 1 of G1 norovirus with similar efficiency, and that enzymatic activity of both proteases was inhibited by commercial protease inhibitors including chymostatin. The interaction of chymostatin to Norwalk virus protease was validated by nuclear magnetic resonance (NMR) spectroscopy.

  7. Characterization and inhibition of norovirus proteases of genogroups I and II using a fluorescence resonance energy transfer assay

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kyeong-Ok [Department of Diagnostic Medicine and Pathobiology, College of Veterinary Medicine, Kansas State University, KS 66506 (United States); Takahashi, Daisuke; Prakash, Om [Department of Biochemistry, Kansas State University, Manhattan, KS 66506 (United States); Kim, Yunjeong, E-mail: ykim@vet.ksu.edu [Department of Diagnostic Medicine and Pathobiology, College of Veterinary Medicine, Kansas State University, KS 66506 (United States)

    2012-02-20

    Noroviruses are the major cause of food- or water-borne gastroenteritis outbreaks in humans. The norovirus protease that cleaves a large viral polyprotein to nonstructural proteins is essential for virus replication and an attractive target for antiviral drug development. Noroviruses show high genetic diversity with at least five genogroups, GI-GV, of which GI and GII are responsible for the majority of norovirus infections in humans. We cloned and expressed proteases of Norwalk virus (GI) and MD145 virus (GII) and characterized the enzymatic activities with fluorescence resonance energy transfer substrates. We demonstrated that the GI and GII proteases cleaved the substrates derived from the naturally occurring cleavage site in the open reading frame (ORF) 1 of G1 norovirus with similar efficiency, and that enzymatic activity of both proteases was inhibited by commercial protease inhibitors including chymostatin. The interaction of chymostatin to Norwalk virus protease was validated by nuclear magnetic resonance (NMR) spectroscopy.

  8. Commissioning and Early Operation for the NSLS-II Booster RF System

    Energy Technology Data Exchange (ETDEWEB)

    Marques, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cupolo, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Davila, P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gao, F. [Brookhaven National Lab. (BNL), Upton, NY (United States); Goel, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Holub, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Kulpin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); McDonald, K. [Brookhaven National Lab. (BNL), Upton, NY (United States); Oliva, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Papu, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ramirez, G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rose, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sikora, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sorrentino, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Towne, N. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    The National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory (BNL) is a third generation 3GeV, 500mA synchrotron light source. We discuss the booster synchrotron RF system responsible for providing power to accelerate an electron beam from 200MeV to 3GeV. The RF system design and construction are complete and is currently in the operational phase of the NSLS-II project. Preliminary operational data is also discussed.

  9. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

    Science.gov (United States)

    Rabel, Annette; Köhler, Steffen Gerhard; Schmidt-Westhausen, Andrea Maria

    2007-09-01

    Primary stability has a major impact on the long-term success of dental implants. The aim of this study was to investigate the correlation of resonance frequency analysis (RFA) and insertion torque of self-tapping and non-self-tapping implants and their respective differences in primary stability. A group of 263 patients were treated with a total of 602 conically formed dental implants: 408 non-self-tapping Ankylos and 194 self-tapping Camlog. The maximum insertion torque during implant placement was recorded. Resonance frequency, measured as the implant stability quotient (ISQ), was assessed once immediately after insertion and twice 3 months later. Torque values of the non-self-tapping implants were significantly higher than those in the self-tapping group (p = 0.023). RFA did not show differences between the 2 groups (p = 0.956), but a correlation between ISQ values after implantation and 3 months after implant placement was measured (r = 0.712). Within the implant systems, no correlation between insertion torque and resonance frequency values could be determined (r = 0.305). Our study indicates that the ISQ values obtained from different implant systems are not comparable. The RFA does not appear suitable for the evaluation of implant stability when used as a single method. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical primary stability.

  10. Cross-diffusion-induced subharmonic spatial resonances in a predator-prey system

    Science.gov (United States)

    Gambino, G.; Lombardo, M. C.; Sammartino, M.

    2018-01-01

    In this paper we investigate the complex dynamics originated by a cross-diffusion-induced subharmonic destabilization of the fundamental subcritical Turing mode in a predator-prey reaction-diffusion system. The model we consider consists of a two-species Lotka-Volterra system with linear diffusion and a nonlinear cross-diffusion term in the predator equation. The taxis term in the search strategy of the predator is responsible for the onset of complex dynamics. In fact, our model does not exhibit any Hopf or wave instability, and on the basis of the linear analysis one should only expect stationary patterns; nevertheless, the presence of the nonlinear cross-diffusion term is able to induce a secondary instability: due to a subharmonic spatial resonance, the stationary primary branch bifurcates to an out-of-phase oscillating solution. Noticeably, the strong resonance between the harmonic and the subharmonic is able to generate the oscillating pattern albeit the subharmonic is below criticality. We show that, as the control parameter is varied, the oscillating solution (sub T mode) can undergo a sequence of secondary instabilities, generating a transition toward chaotic dynamics. Finally, we investigate the emergence of sub T -mode solutions on two-dimensional domains: when the fundamental mode describes a square pattern, subharmonic resonance originates oscillating square patterns. In the case of subcritical Turing hexagon solutions, the internal interactions with a subharmonic mode are able to generate the so-called "twinkling-eyes" pattern.

  11. Stochastic resonance in multi-stable coupled systems driven by two driving signals

    Science.gov (United States)

    Xu, Pengfei; Jin, Yanfei

    2018-02-01

    The stochastic resonance (SR) in multi-stable coupled systems subjected to Gaussian white noises and two different driving signals is investigated in this paper. Using the adiabatic approximation and the perturbation method, the coupled systems with four-well potential are transformed into the master equations and the amplitude of the response is obtained. The signal-to-noise ratio (SNR) is calculated numerically to demonstrate the occurrence of SR. For the case of two driving signals with different amplitudes, the interwell resonance between two wells S1 and S3 emerges for strong coupling. The SR can appear in the subsystem with weaker signal amplitude or even without driving signal with the help of coupling. For the case of two driving signals with different frequencies, the effects of SR in two subsystems driven by high and low frequency signals are both weakened with an increase in coupling strength. The stochastic multi-resonance phenomenon is observed in the subsystem subjected to the low frequency signal. Moreover, an effective scheme for phase suppressing SR is proposed by using a relative phase between two driving signals.

  12. Contribution to analytical theory of neutron resonance absorption in heterogeneous reactor systems with cylindrical geometry

    International Nuclear Information System (INIS)

    Slipicevic, K.

    1968-12-01

    Following a review of the existing theories od resonance absorption this thesis includes a new approach for calculating the effective resonance integral of absorbed neutrons, new approximate formula for the penetration factor, an analysis of the effective resonance integral and the correction of the resonance integral taking into account the interference of potential and resonance dissipation. A separate chapter is devoted to calculation of the effective resonance integral for the regular reactor lattice with cylindrical fuel elements

  13. Characterization of monomeric Mn(II/III/IV)-hydroxo complexes from X- and Q-band dual mode electron paramagnetic resonance (EPR) spectroscopy.

    Science.gov (United States)

    Gupta, Rupal; Taguchi, Taketo; Borovik, A S; Hendrich, Michael P

    2013-11-04

    Manganese-hydroxo species have been implicated in C-H bond activation performed by metalloenzymes, but the electronic properties of many of these intermediates are not well characterized. The present work presents a detailed characterization of three Mn(n)-OH complexes (where n = II, III, and IV) of the tris[(N'-tert-butylureaylato)-N-ethylene]aminato ([H3buea](3-)) ligand using X- and Q-band dual mode electron paramagnetic resonance (EPR). Quantitative simulations for the [Mn(II)H3buea(OH)](2-) complex demonstrated the ability to characterize similar Mn(II) species commonly present in the resting states of manganese-containing enzymes. The spin states of the Mn(III) and Mn(IV) complexes determined from EPR spectroscopy are S = 2 and 3/2, respectively, as expected for the C3 symmetry imposed by the [H3buea](3-) ligand. Simulations of the spectra indicated the constant presence of two Mn(IV) species in solutions of [Mn(IV)H3buea(OH)] complex. The simulations of perpendicular- and parallel-mode EPR spectra allow determination of zero-field splitting and hyperfine parameters for all complexes. For the Mn(III) and Mn(IV) complexes, density functional theory calculations are used to determine the isotropic Mn hyperfine values, to compare the excited electronic state energies, and to give theoretical estimates of the zero-field energy.

  14. Multimoded reflective delay lines and their application to resonant delay line rf pulse compression systems

    Directory of Open Access Journals (Sweden)

    Sami G. Tantawi

    2004-03-01

    Full Text Available Pulse compression systems for future linear colliders, such as NLC and JLC, involve hundreds of kilometers of waveguide runs. These waveguides are highly overmoded to reduce the rf losses. In this paper we present a novel idea for utilizing these waveguides several times by using different modes. This idea is suitable for reflective delay lines. All the modes being used have low-loss characteristics. We describe mechanically simple mode transducers that switch the propagation mode from one configuration to another with no observable dispersion. We apply this technique to a resonant delay line pulse compression system. We also present experimental results that verify these theoretical developments.

  15. Fractal Scaling Models of Resonant Oscillations in Chain Systems of Harmonic Oscillators

    Directory of Open Access Journals (Sweden)

    Müller H.

    2009-04-01

    Full Text Available Logarithmic scaling invariance is a wide distributed natural phenomenon and was proved in the distributions of physical properties of various processes — in high en- ergy physics, chemistry, seismicity, biology, geology and technology. Based on the Gantmacher-Krein continued fraction method the present paper introduces fractal scal- ing models of resonant oscillations in chain systems of harmonic oscillators. These models generate logarithmic scaling spectra. The introduced models are not based on any statements about the nature of the link or interaction between the elements of the oscillating system. Therefore the model statements are quite generally, what opens a wide field of possible applications.

  16. Study of resonant magnet exciting system for the 3 GeV proton synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, Shoichiro; Zhang, Fengqing; Watanabe, Yasuhiro; Tani, Norio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Adachi, Toshikazu; Someya, Hirohiko [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-07-01

    Exciting system for magnets of the 3 GeV Proton synchrotron is under consideration. A resonant exciting system is studied, and two type of power supply are compared. One is a parallel supply that is used generally. Another is a modified series supply. Either of them uses IGBT sinusoidal converters. Capacity of the power converter of the series supply for bending magnets becomes 28.8 MVAp. This is lager more than twice compared with the parallel supply. In the other hand, the series supply has good control performance and flexibility. More study is necessary to decide finally. (author)

  17. Multifunctional Aerogel Thermal Protection Systems for Hypersonic Vehicles, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall objective of the Phase II project is to develop lightweight reinforced aerogel materials for use as the core structural insulation material in...

  18. Recession-Tolerant Sensors for Thermal Protection Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase II project will develop a suite of diagnostic sensors using Direct Write technology to measure temperature, surface recession depth, and heat flux of an...

  19. Multi-Layered Integrated Airframe System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposed Phase II program builds on the Phase I effort addressing NASA's future mission requirements by: 1) developing higher performing TPS materials capable...

  20. An Outrigger Component for a Deployable Occulter System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase II, Roccor proposes to build upon the results of Phase I to increase the technology readiness level (TRL) of the NASA JPL deployable external occulter. An...

  1. Novel Instrumentation for Rocket Propulsion Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the proposed SBIR Phase II program is to develop, deploy and deliver novel laser-based instruments that provide rapid, in situ, simultaneous...

  2. Quantification of Uncertainties in Integrated Spacecraft System Models, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective for the Phase II effort will be to develop a comprehensive, efficient, and flexible uncertainty quantification (UQ) framework implemented within a...

  3. Intensity-based readout of resonant-waveguide grating biosensors: Systems and nanostructures

    Science.gov (United States)

    Paulsen, Moritz; Jahns, Sabrina; Gerken, Martina

    2017-09-01

    Resonant waveguide gratings (RWG) - also called photonic crystal slabs (PCS) - have been established as reliable optical transducers for label-free biochemical assays as well as for cell-based assays. Current readout systems are based on mechanical scanning and spectrometric measurements with system sizes suitable for laboratory equipment. Here, we review recent progress in compact intensity-based readout systems for point-of-care (POC) applications. We briefly introduce PCSs as sensitive optical transducers and introduce different approaches for intensity-based readout systems. Photometric measurements have been realized with a simple combination of a light source and a photodetector. Recently a 96-channel, intensity-based readout system for both biochemical interaction analyses as well as cellular assays was presented employing the intensity change of a near cut-off mode. As an alternative for multiparametric detection, a camera system for imaging detection has been implemented. A portable, camera-based system of size 13 cm × 4.9 cm × 3.5 cm with six detection areas on an RWG surface area of 11 mm × 7 mm has been demonstrated for the parallel detection of six protein binding kinetics. The signal-to-noise ratio of this system corresponds to a limit of detection of 168 M (24 ng/ml). To further improve the signal-to-noise ratio advanced nanostructure designs are investigated for RWGs. Here, results on multiperiodic and deterministic aperiodic nanostructures are presented. These advanced nanostructures allow for the design of the number and wavelengths of the RWG resonances. In the context of intensity-based readout systems they are particularly interesting for the realization of multi-LED systems. These recent trends suggest that compact point-of-care systems employing disposable test chips with RWG functional areas may reach market in the near future.

  4. Strangeness freeze-out: role of system size and missing resonances

    Directory of Open Access Journals (Sweden)

    Chatterjee Sandeep

    2018-01-01

    Full Text Available The conventional approach to treat strangeness freezeout has been to consider a unified freezeout scheme where strangeness freezes out along with the nonstrange hadrons (1CFO, with or without an additional parameter accounting for out-of-equilibrium strangeness production (γS. Several alternate scenarios have been formulated lately. Here, we will focus on flavor dependent freezeout with early freezeout of strangeness (2CFO in comparison to 1CFO and its variants with respect to the roles played by the system size and missing resonances predicted by different theoretical approaches but yet to be seen in experiments. In contrast to the performance of 1CFO with/without γS that is insensitive to system size, 2CFO exhibits a clear system size dependence-while for Pb+Pb the χ2/NDF is around 0-2, for smaller system size in p+Pb and p+p, the χ2/NDF> 5 and larger than 1CFO+γS. This clearly shows a system size dependence of the preference for the freezeout scheme, while 2CFO is preferred in Pb+Pb, 1CFO+γS is preferred in p+Pb and p+p. We have further investigated the role of the missing resonances on strangeness freezeout across SPS to LHC beam energies.

  5. CURRENT-VOLTAGE CHARACTERISTICS FOR TWO SYSTEMS OF QUANTUM WAVEGUIDES WITH CONNECTED QUANTUM RESONATORS

    Directory of Open Access Journals (Sweden)

    A. S. Bagmutov

    2016-07-01

    Full Text Available We investigate two 2D quantum systems, each consisting of a waveguide and a resonator, connected through narrow holes. Systems features are studied by the solution of scattering problem. We use zero-width slits model, where the finite radius is changed by infinitely-small one. In the framework of the proposed model, exact solutions are found and scattering problem is solved for both systems using the theory of self-adjoint extensions of symmetric operators. Obtained results are then used to calculate current-voltage characteristics of suggested systems. We show that obtained characteristics have steplike kinks disappearing with the temperature growth or increase of system sizes. Parameters are calculated with the effect still observable. The results may be useful in the design of electronic devices such as nanoelectronic transistor based on resistance control in a waveguide.

  6. Mitigation Emission Strategy Based on Resonances from a Power Inverter System in Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Li Zhai

    2016-05-01

    Full Text Available Large dv/dt and di/dt outputs of power devices in the DC-fed motor power inverter can generate conducted and/or radiated emissions through parasitics that interfere with low voltage electric systems in electric vehicles (EVs and nearby vehicles. The electromagnetic interference (EMI filters, ferrite chokes, and shielding added in the product process based on the “black box” approach can reduce the emission levels in a specific frequency range. However, these countermeasures may also introduce an unexpected increase in EMI noises in other frequency ranges due to added capacitances and inductances in filters resonating with elements of the power inverter, and even increase the weight and dimension of the power inverter system in EVs with limited space. In order to predict the interaction between the mitigation techniques and power inverter geometry, an accurate model of the system is needed. A power inverter system was modeled based on series of two-port network measurements to study the impact of EMI generated by power devices on radiated emission of AC cables. Parallel resonances within the circuit can cause peaks in the S21 (transmission coefficient between the phase-node-to-chassis voltage and the center-conductor-to-shield voltage of the AC cable connecting to the motor and Z11 (input impedance at Port 1 between the Insulated gate bipolar transistor (IGBT phase node and chassis at those resonance frequencies and result in enlarged noise voltage peaks at Port 1. The magnitude of S21 between two ports was reduced to decrease the amount of energy coupled from the noise source between the phase node and chassis to the end of the AC cable by lowering the corresponding quality factor. The equivalent circuits were built by analyzing current-following paths at three critical resonance frequencies. Interference voltage peaks can be suppressed by mitigating the resonances. The capacitances and inductances generating the parallel resonances and

  7. Enhancement effects of reducing agents on the degradation of tetrachloroethene in the Fe(II)/Fe(III) catalyzed percarbonate system

    International Nuclear Information System (INIS)

    Miao, Zhouwei; Gu, Xiaogang; Lu, Shuguang; Brusseau, Mark L.; Yan, Ni; Qiu, Zhaofu; Sui, Qian

    2015-01-01

    Highlights: • PCE degradation by reducing-agent modified Fe-catalyzed percarbonate was studied. • The addition of reducing agents significantly increased PCE degradation. • Hydroxylamine hydrochloride showed the best effect on enhancing PCE degradation. • The primary PCE degradation mechanism was oxidation by hydroxyl radical. • O 2 · − participated in the degradation of PCE in reducing-agent modified system. - Abstract: In this study, the effects of reducing agents on the degradation of tetrachloroethene (PCE) were investigated in the Fe(II)/Fe(III) catalyzed sodium percarbonate (SPC) system. The addition of reducing agents, including hydroxylamine hydrochloride, sodium sulfite, ascorbic acid and sodium ascorbate, accelerated the Fe(III)/Fe(II) redox cycle, leading to a relatively steady Fe(II) concentration and higher production of free radicals. This, in turn, resulted in enhanced PCE oxidation by SPC, with almost complete PCE removal obtained for appropriate Fe and SPC concentrations. The chemical probe tests, using nitrobenzene and carbon tetrachloride, demonstrated that HO· was the predominant radical in the system and that O 2 · − played a minor role, which was further confirmed by the results of electron spin resonance measurements. PCE degradation decreased significantly with the addition of isopropanol, a HO· scavenger, supporting the hypothesis that HO· was primarily responsible for PCE degradation. It is noteworthy that Cl − release was slightly delayed in the first 20 min, indicating that intermediate products were produced. However, these intermediates were further degraded, resulting in the complete conversion of PCE to CO 2 . In conclusion, the use of reducing agents to enhance Fe(II)/Fe(III) catalyzed SPC oxidation appears to be a promising approach for the rapid degradation of organic contaminants in groundwater.

  8. Enhancement effects of reducing agents on the degradation of tetrachloroethene in the Fe(II)/Fe(III) catalyzed percarbonate system

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Zhouwei [State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, East China University of Science and Technology, Shanghai 200237 (China); Soil, Water and Environmental Science Department, School of Earth and Environmental Sciences, The University of Arizona, 429 Shantz Building, Tucson, AZ 85721 (United States); Gu, Xiaogang [State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, East China University of Science and Technology, Shanghai 200237 (China); Lu, Shuguang, E-mail: lvshuguang@ecust.edu.cn [State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, East China University of Science and Technology, Shanghai 200237 (China); Brusseau, Mark L. [Soil, Water and Environmental Science Department, School of Earth and Environmental Sciences, The University of Arizona, 429 Shantz Building, Tucson, AZ 85721 (United States); Yan, Ni [Hydrology and Water Resources Department, School of Earth and Environmental Sciences, University of Arizona, 429 Shantz Building, Tucson, AZ 85721 (United States); Qiu, Zhaofu; Sui, Qian [State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, East China University of Science and Technology, Shanghai 200237 (China)

    2015-12-30

    Highlights: • PCE degradation by reducing-agent modified Fe-catalyzed percarbonate was studied. • The addition of reducing agents significantly increased PCE degradation. • Hydroxylamine hydrochloride showed the best effect on enhancing PCE degradation. • The primary PCE degradation mechanism was oxidation by hydroxyl radical. • O{sub 2}·{sup −} participated in the degradation of PCE in reducing-agent modified system. - Abstract: In this study, the effects of reducing agents on the degradation of tetrachloroethene (PCE) were investigated in the Fe(II)/Fe(III) catalyzed sodium percarbonate (SPC) system. The addition of reducing agents, including hydroxylamine hydrochloride, sodium sulfite, ascorbic acid and sodium ascorbate, accelerated the Fe(III)/Fe(II) redox cycle, leading to a relatively steady Fe(II) concentration and higher production of free radicals. This, in turn, resulted in enhanced PCE oxidation by SPC, with almost complete PCE removal obtained for appropriate Fe and SPC concentrations. The chemical probe tests, using nitrobenzene and carbon tetrachloride, demonstrated that HO· was the predominant radical in the system and that O{sub 2}·{sup −} played a minor role, which was further confirmed by the results of electron spin resonance measurements. PCE degradation decreased significantly with the addition of isopropanol, a HO· scavenger, supporting the hypothesis that HO· was primarily responsible for PCE degradation. It is noteworthy that Cl{sup −} release was slightly delayed in the first 20 min, indicating that intermediate products were produced. However, these intermediates were further degraded, resulting in the complete conversion of PCE to CO{sub 2}. In conclusion, the use of reducing agents to enhance Fe(II)/Fe(III) catalyzed SPC oxidation appears to be a promising approach for the rapid degradation of organic contaminants in groundwater.

  9. Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors

    Science.gov (United States)

    Patil, Hardik U.

    Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be

  10. Search for a $Z(4430)^{\\pm} \\to \\psi(2S)\\pi^{\\pm}$ resonance in hadron collisions at CDF II

    Energy Technology Data Exchange (ETDEWEB)

    Rubbo, Francesco [Univ. of Turin, Torino (Italy)

    2010-01-01

    The work described in this thesis is the first search for a Z-(4430) resonance in hadron collisions and has been conceived, carried out and concluded entirely by the author. An ad-hoc analysis framework has been developed based on reconstruction code already consolidated in other analysis, adapted and modified for the purpose of this work. The progress of the work has been periodically presented in internal meetings of the CDF B-physics group and documented in internal notes.

  11. Resonant two-photon absorption and electromagnetically induced transparency in open ladder-type atomic system.

    Science.gov (United States)

    Moon, Han Seb; Noh, Heung-Ryoul

    2013-03-25

    We have experimentally and theoretically studied resonant two-photon absorption (TPA) and electromagnetically induced transparency (EIT) in the open ladder-type atomic system of the 5S(1/2) (F = 1)-5P(3/2) (F' = 0, 1, 2)-5D(5/2) (F″ = 1, 2, 3) transitions in (87)Rb atoms. As the coupling laser intensity was increased, the resonant TPA was transformed to EIT for the 5S(1/2) (F = 1)-5P(3/2) (F' = 2)-5D(5/2) (F″ = 3) transition. The transformation of resonant TPA into EIT was numerically calculated for various coupling laser intensities, considering all the degenerate magnetic sublevels of the 5S(1/2)-5P(3/2)-5D(5/2) transition. From the numerical results, the crossover from TPA to EIT could be understood by the decomposition of the spectrum into an EIT component owing to the pure two-photon coherence and a TPA component caused by the mixed term.

  12. Intraoperative Magnetic-Resonance Tomography and Neuronavigation During Resection of Focal Cortical Dysplasia Type II in Adult Epilepsy Surgery Offers Better Seizure Outcomes.

    Science.gov (United States)

    Roessler, Karl; Kasper, Burkhard S; Heynold, Elisabeth; Coras, Roland; Sommer, Björn; Rampp, Stefan; Hamer, Hajo M; Blümcke, Ingmar; Buchfelder, Michael

    2018-01-01

    Focal cortical dysplasia (FCD) is one important cause of drug-resistant epilepsy potentially curable by epilepsy surgery. We investigated the options of using neuronavigation and intraoperative magnetic-resonance tomographical imaging (MRI) to avoid residual epileptogenic tissue during resection of patients with FCD II to improve seizure outcome. Altogether, 24 patients with FCD II diagnosed by MRI (16 female, 8 male; mean age 34 ± 10 years) suffered from drug-resistant electroclinical and focal epilepsy for a mean of 20.7 ± 5 years. Surgery was performed with preoperative stereoelectroencephalography (in 15 patients), neuronavigation, and intraoperative 1.5T-iopMRI in all 24 investigated patients. In 75% of patients (18/24), a complete resection was performed. In 89% (16/18) of completely resected patients, we documented an Engel I seizure outcome after a mean follow-up of 42 months. All incompletely resected patients had a worse outcome (Engel II-III, P < 0.0002). Patients with FCD IIB had also significant better seizure outcome compared with patients diagnosed as having FCD IIA (82% vs. 28%, P < 0.02). In 46% (11/24) of patients, intraoperative second-look surgeries due to residual lesions detected during the intraoperative MRI were performed. In these 11 patients, there were significant more completely seizure free patients (73% vs. 38% Engel IA), compared with 13 patients who finished surgery after the first intraoperative MRI (P < 0.05). Excellent seizure outcome after surgery of patients with FCD II positively correlated with the amount of resection, histologic subtype, and the use of intraoperative MRI, especially when intraoperative second-look surgeries were performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Windowed SHE-PWM of Interleaved Four-Quadrant Converters for Resonance Suppression in Traction Power Supply Systems

    DEFF Research Database (Denmark)

    Song, Kejian; Konstantinou, Georgios; Mingli, Wu

    2017-01-01

    AC electric locomotives that use a number of interleaved four-quadrant converters generate high-frequency switching harmonics which may stimulate certain resonances in traction power supply systems (TPSSs). A windowed selective harmonic elimination pulse-width modulation (SHE-PWM) method...... is proposed to suppress such resonances. Owing to the windowed design and the precalculated solutions, the proposed method covers the wide potential resonant frequency range and addresses the resonant frequency variation while keeping the low switching frequency of the traction converters. The proposed...... windowed SHE-PWM is fully tested with a closed-loop controller in a simulation model with the TPSS and the ac electric locomotive. Comparative simulation results show that the windowed SHE-PWM is an effective alternative that overcomes the resonance suppression limitations of the conventional phase...

  14. Spallation Neutron Source Drift Tube Linac Resonance Control Cooling System Modeling

    CERN Document Server

    Tang, Johnny Y; Champion, Marianne M; Feschenko, Alexander; Gibson, Paul; Kiselev, Yuri; Kovalishin, A S; Kravchuk, Leonid V; Kvasha, Adolf; Schubert, James P

    2005-01-01

    The Resonance Control Cooling System (RCCS) for the warm linac of the Spallation Neutron Source was designed by Los Alamos National Laboratory. The primary design focus was on water cooling of individual component contributions. The sizing the RCCS water skid was accomplished by means of a specially created SINDA/FLUINT model tailored to these system requirements. A new model was developed in Matlab Simulink and incorporates actual operational values and control valve interactions. Included is the dependence of RF input power on system operation, cavity detuning values during transients, time delays that result from water flows through the heat exchanger, the dynamic process of water warm-up in the cooling system due to dissipated RF power on the cavity surface, differing contributions on the cavity detuning due to drift tube and wall heating, and a dynamic model of the heat exchanger with characteristics in close agreement to the real unit. Because of the Matlab Simulink model, investigation of a wide range ...

  15. Prominent porto-systemic collateral pathways in patients with portal hypertension: demonstration by gadolinium-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Caldana, Rogerio Pedreschi; Bezerra, Alexandre Araujo Sergio; Cecin, Alexnadre Oliveira; Souza, Luis Ronan Marques Ferreira de; Goldman, Susan Menasce; D'Ippolito, Giuseppe; Szejnfeld, Jacob

    2003-01-01

    To demonstrate the usefulness of gadolinium-enhanced magnetic resonance angiography in the evaluation of prominent porto-systemic collateral pathways. We reviewed the images from 40 patients with portal hypertension studied with gadolinium-enhanced magnetic resonance angiography and selected illustrative cases of prominent porto-systemic collateral pathways. The scans were performed using high field equipment (1.5 Tesla) and a 3 D volume technique. Image were obtained after intravenous injection of paramagnetic contrast media using a power injector. Magnetic resonance angiography demonstrated with precision the porto-systemic collateral pathways, particularly when investigating extensive territories or large vessels. The cases presented show the potential of this method in the investigation of patients with portal hypertension. Gadolinium-enhanced magnetic resonance angiography is a useful method for the evaluation of patients with portal hypertension and prominent collateral pathways. (author)

  16. River Protection Project Integrated safety management system phase II verification report, volumes I and II - 8/19/99

    Energy Technology Data Exchange (ETDEWEB)

    SHOOP, D.S.

    1999-09-10

    The Department of Energy policy (DOE P 450.4) is that safety is integrated into all aspects of the management and operations of its facilities. In simple and straightforward terms, the Department will ''Do work safely.'' The purpose of this River Protection Project (RPP) Integrated Safety Management System (ISMS) Phase II Verification was to determine whether ISMS programs and processes are implemented within RFP to accomplish the goal of ''Do work safely.'' The goal of an implemented ISMS is to have a single integrated system that includes Environment, Safety, and Health (ES&H) requirements in the work planning and execution processes to ensure the protection of the worker, public, environment, and federal property over the RPP life cycle. The ISMS is comprised of the (1) described functions, components, processes, and interfaces (system map or blueprint) and (2) personnel who are executing those assigned roles and responsibilities to manage and control the ISMS. Therefore, this review evaluated both the ''paper'' and ''people'' aspects of the ISMS to ensure that the system is implemented within RPP. Richland Operations Office (RL) conducted an ISMS Phase I Verification of the TWRS from September 28-October 9, 1998. The resulting verification report recommended that TWRS-RL and the contractor proceed with Phase II of ISMS verification given that the concerns identified from the Phase I verification review are incorporated into the Phase II implementation plan.

  17. Computer measurement system of reactor period for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1997-01-01

    The author simply introduces the hardware, principle, and software of the reactor period computer measure system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between Fission yield and Pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computer measure system makes the reactor period measurement into automation and intellectualization and also improves the speed and precision of period data process on-line

  18. The computerized reactor period measurement system for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1996-01-01

    The article simply introduces the hardware, principle, and software of the computerized reactor period measurement system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between fission yield and pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computerized measurement system makes the reactor period measurement into automatical and intelligent and also improves the speed and precision of period data on-line process

  19. Performance and analysis of wireless power charging system from room temperature to HTS magnet via strong resonance coupling method

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. D.; Lee, S. Y.; Lee, T. W.; Kim, J. S. [Suwon Science College, Suwon (Korea, Republic of); Lee, C. Y. [Korea Railroad Institute, Uiwang (Korea, Republic of)

    2016-03-15

    The technology of supplying the electric power by wireless power transfer (WPT) is expected for the next generation power feeding system since it can supply the power to portable devices without any connectors through large air gap. As such a technology based on strongly coupled electromagnetic resonators is possible to deliver the large power and recharge them seamlessly; it has been considered as a noble option to wireless power charging system in the various power applications. Recently, various HTS wires have now been manufactured for demonstrations of transmission cables, motors, MAGLEV, and other electrical power components. However, since the HTS magnets have a lower index n value intrinsically, they are required to be charged from external power system through leads or internal power system. The portable area is limited as well as the cryogen system is bulkier. Thus, we proposed a novel design of wireless power charging system for superconducting HTS magnet (WPC4SM) based on resonance coupling method. As the novel system makes possible a wireless power charging using copper resonance coupled coils, it enables to portable charging conveniently in the superconducting applications. This paper presented the conceptual design and operating characteristics of WPC4SM using different shapes' copper resonance coil. The proposed system consists of four components; RF generator of 370 kHz, copper resonance coupling coils, impedance matching (IM) subsystem and HTS magnet including rectifier system.

  20. Prognostic value of left atrial function in systemic light-chain amyloidosis: a cardiac magnetic resonance study.

    Science.gov (United States)

    Mohty, Dania; Boulogne, Cyrille; Magne, Julien; Varroud-Vial, Nicolas; Martin, Sylvain; Ettaif, Hind; Fadel, Bahaa M; Bridoux, Frank; Aboyans, Victor; Damy, Thibaud; Jaccard, Arnaud

    2016-09-01

    Cardiac involvement in systemic light-chain amyloidosis (AL) imparts an adverse impact on outcome. The left atrium (LA), by virtue of its anatomical location and muscular wall, is commonly affected by the amyloid process. Although LA infiltration by amyloid fibrils leads to a reduction in its pump function, the infiltration of the left ventricular (LV) myocardium results in diastolic dysfunction with subsequent increase in filling pressures and LA enlargement. Even though left atrial volume (LAV) is an independent prognostic marker in many cardiomyopathies, its value in amyloid heart disease remains to be determined. In addition, few data are available as to the prognostic value of LA function in systemic AL. Using cardiac magnetic resonance (CMR), the current study aims to assess the prognostic significance of the maximal LAV and total LA emptying fraction (LAEF) in patients with AL. Fifty-four consecutive patients (age 66 ± 10 years, 59% males) with confirmed systemic AL and mean LV ejection fraction of 60 ± 12% underwent CMR. As compared with patients with no or minimal cardiac involvement (Mayo Clinic [MC] stage I), those at moderate and high risk (MC stages II and III) had significantly larger indexed maximal LAV (36 ± 15 vs. 46 ± 13 vs. 52 ± 19 mL/m(2), P = 0.03) and indexed minimal LAV (20 ± 6 vs. 34 ± 11 vs. 44 ± 17 mL/m(2), P 16% (37 ± 11 vs. 94 ± 4%, P = 0.001). In multivariate analysis, lower LAEF remained independently associated with a higher risk of 2-year mortality (HR = 1.08 per 1% decrease, 95% CI: 1.02-1.15, P = 0.003). In patients with systemic AL, LAEF as assessed by CMR is associated with NYHA functional class, MC stage, myocardial LGE and 2-year mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  1. Peliosis hepatis and systemic lupus erythematosus: A rare condition identified by magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Rafael Alves Cordeiro

    Full Text Available Summary Peliosis hepatis is a rare benign disorder characterized by the presence of multiple cavities filled with blood with no preferential localization in the liver parenchyma. It may be related to several etiologic conditions, especially infections and toxicity of immunosuppressive drugs. To our knowledge, there are only three articles reporting the association between peliosis hepatis and systemic lupus erythematosus. In this report, we describe a case of this rare condition, highlighting the importance of magnetic resonance imaging. A short review of this subject is also presented.

  2. A hybrid active filter for damping of harmonic resonance in industrial power systems

    OpenAIRE

    Fujita, Hideaki; Yamasaki, Takahiro; Akagi, Hirofumi

    1998-01-01

    This paper proposes a hybrid active filter for damping of harmonic resonance in industrial power systems. The hybrid filter consists of a small-rated active filter and a 5th tuned passive filter. The active filter is characterized by detecting the 5th harmonic current flowing into the passive filter. It is controlled in such a way as to behave as a negative or positive resistor by adjusting a feedback gain from a negative to positive value, and vice versa. The negative resistor presented by t...

  3. Realization of quantum state privacy amplification in a nuclear magnetic resonance quantum system

    International Nuclear Information System (INIS)

    Hao, Liang; Wang, Chuan; Long, Gui Lu

    2010-01-01

    Quantum state privacy amplification (QSPA) is the quantum analogue of classical privacy amplification. If the state information of a series of single-particle states has some leakage, QSPA reduces this leakage by condensing the state information of two particles into the state of one particle. Recursive applications of the operations will eliminate the quantum state information leakage to a required minimum level. In this paper, we report the experimental implementation of a quantum state privacy amplification protocol in a nuclear magnetic resonance system. The density matrices of the states are constructed in the experiment, and the experimental results agree well with theory.

  4. Synthetic-gauge-field-induced Dirac semimetal state in an acoustic resonator system

    Science.gov (United States)

    Yang, Zhaoju; Gao, Fei; Shi, Xihang; Zhang, Baile

    2016-12-01

    Recently, a proposal of synthetic gauge field in reduced two-dimensional (2D) system from three-dimensional (3D) acoustic structure shows an analogue of the gapped Haldane model with fixed k z , and achieves the gapless Weyl semimetal phase in 3D momentum space. Here, extending this approach of synthetic gauge flux, we propose a reduced square lattice of acoustic resonators, which exhibits Dirac nodes with broken effective time-reversal symmetry. Protected by an additional hidden symmetry, these Dirac nodes with quantized values of topological charge are characterized by nonzero winding number and the finite structure exhibits flat edge modes that cannot be destroyed by perturbations.

  5. Magnetically assisted delivery of cells using a magnetic resonance imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Riegler, J [Centre for Advanced Biomedical Imaging (CABI), Department of Medicine and Institute of Child Health, University College London (UCL), London WC1E 6DD (United Kingdom); Allain, B [Centre for Medical Image Computing (CMIC) UCL, London WC1E 6BT (United Kingdom); Cook, R J [KCL Dental Institute, Biomaterials, Biomimetics and Biophotonics Group, C/O Floor 17 Tower Wing, Guy' s Hospital Campus, Great Maze Pond, London SE1 9RT (United Kingdom); Lythgoe, M F [Centre for Mathematics and Physics in the Life Sciences and Experimental Biology (CoMPLEX), UCL, London WC1E 6BT (United Kingdom); Pankhurst, Q A, E-mail: j.riegler@ucl.ac.uk [Davy-Faraday Research Laboratory, The Royal Institution of Great Britain, 21 Albemarle Street, London W1S 4BS (United Kingdom)

    2011-02-09

    A simple analytical model is presented which enables rapid interactive prediction and control of magnetically labelled cells in an arterial bifurcation using magnetic field gradients produced by a magnetic resonance imaging (MRI) system. This model is compared against experimental results for human mononuclear cells labelled with micrometre sized superparamagnetic iron oxide particles. Experimental and theoretical results highlight the importance of cell aggregation for magnetic targeting in a strong magnetic field. These predicted aggregates are confirmed via confocal endoscopy which allows the visualization of cell aggregates and their movement inside a vascular flow model in a 9.4 T preclinical MRI scanner.

  6. A compact Class D RF power amplifier for mobile nuclear magnetic resonance systems

    Science.gov (United States)

    Zhen, J.; Dykstra, R.; Eccles, C.; Gouws, G.; Obruchkov, S.

    2017-07-01

    A 20 MHz Class D amplifier with an output of 100 W of RF power has been developed. The compact size printed circuit board area of 50 cm2 and efficiency of 73% make it suitable for mobile nuclear magnetic resonance (NMR) systems. Test results show that the rise and ring down times of the amplifier are less than 0.2 μs, and it is capable of producing constant amplitude pulses as short as 2 μs. Experiments using a Carr Purcell Meiboom Gill pulse sequence with a NMR MOUSE sensor confirm that the Class D amplifier is suitable for mobile NMR applications.

  7. A closed-loop power controller model of series-resonant-inverter-fitted induction heating system

    Directory of Open Access Journals (Sweden)

    Pal Palash

    2016-12-01

    Full Text Available This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.

  8. Kilowatt isotope power system, Phase II Plan. Volume IV. Teledyne FSCD vs GDS

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-15

    This Volume contains Teledyne's input to the Kilowatt Isotope Power System Phase II Plan. Included is a description of the Flight System Heat Generation System, Flight System Radiator, Thermal Insulation Stability, GDS Heat Generation System and GDS Radiator.

  9. Development and initial characterization of a nuclear magnetic resonance dosimetry system

    International Nuclear Information System (INIS)

    Thomasson, D.M.

    1990-01-01

    A novel high dose radiation dosimeter was developed employing NMR spectroscopic quantitation of the radiolytic products of methanol. Chemical shifts of product resonances relative to the solvent allow quantification using NMR techniques. Due to expected dynamic range limitations of NMR instrumentation, deuterated methanol is used with a presaturation suppression sequence to reduce the solvent proton signals. Methanol's 13 C-coupled proton resonances is used as an internal reference to normalize product signals otherwise subject to spectrometer variability. Data on reproducibility, dose response, and temporal stability were acquired. System reproducibility for a sample at 1 kGy is ∼10%. The dose response is linear in the range between 200 Gy and 50 kGy. No significant signal degradation was observed during a six month period. Advantages of this type dosimeter system include ease of use, large dynamic range, and temporal stability. An additional characteristic of a methanol based system is the LET dependent response in the chemical yields of formaldehyde and ethylene glycol. 70 refs., 15 figs., 9 tabs

  10. Excitation power quantities in phase resonance testing of nonlinear systems with phase-locked-loop excitation

    Science.gov (United States)

    Peter, Simon; Leine, Remco I.

    2017-11-01

    Phase resonance testing is one method for the experimental extraction of nonlinear normal modes. This paper proposes a novel method for nonlinear phase resonance testing. Firstly, the issue of appropriate excitation is approached on the basis of excitation power considerations. Therefore, power quantities known from nonlinear systems theory in electrical engineering are transferred to nonlinear structural dynamics applications. A new power-based nonlinear mode indicator function is derived, which is generally applicable, reliable and easy to implement in experiments. Secondly, the tuning of the excitation phase is automated by the use of a Phase-Locked-Loop controller. This method provides a very user-friendly and fast way for obtaining the backbone curve. Furthermore, the method allows to exploit specific advantages of phase control such as the robustness for lightly damped systems and the stabilization of unstable branches of the frequency response. The reduced tuning time for the excitation makes the commonly used free-decay measurements for the extraction of backbone curves unnecessary. Instead, steady-state measurements for every point of the curve are obtained. In conjunction with the new mode indicator function, the correlation of every measured point with the associated nonlinear normal mode of the underlying conservative system can be evaluated. Moreover, it is shown that the analysis of the excitation power helps to locate sources of inaccuracies in the force appropriation process. The method is illustrated by a numerical example and its functionality in experiments is demonstrated on a benchmark beam structure.

  11. Applications of the Hybrid Theory to the Scattering of Electrons from HE+ and Li++ and Resonances in these Systems

    Science.gov (United States)

    Bhatia, Anand K.

    2008-01-01

    Applications of the hybrid theory to the scattering of electrons from Ile+ and Li++ and resonances in these systems, A. K. Bhatia, NASA/Goddard Space Flight Center- The Hybrid theory of electron-hydrogen elastic scattering [I] is applied to the S-wave scattering of electrons from He+ and Li++. In this method, both short-range and long-range correlations are included in the Schrodinger equation at the same time. Phase shifts obtained in this calculation have rigorous lower bounds to the exact phase shifts and they are compared with those obtained using the Feshbach projection operator formalism [2], the close-coupling approach [3], and Harris-Nesbet method [4]. The agreement among all the calculations is very good. These systems have doubly-excited or Feshbach resonances embedded in the continuum. The resonance parameters for the lowest ' S resonances in He and Li+ are calculated and they are compared with the results obtained using the Feshbach projection operator formalism [5,6]. It is concluded that accurate resonance parameters can be obtained by the present method, which has the advantage of including corrections due to neighboring resonances and the continuum in which these resonances are embedded.

  12. A cryogen-free ultralow-field superconducting quantum interference device magnetic resonance imaging system

    International Nuclear Information System (INIS)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2014-01-01

    Magnetic resonance imaging (MRI) at microtesla fields using superconducting quantum interference device (SQUID) detection has previously been demonstrated, and advantages have been noted. Although the ultralow-field SQUID MRI technique would not need the heavy superconducting magnet of conventional MRI systems, liquid helium required to cool the low-temperature detector still places a significant burden on its operation. We have built a prototype cryocooler-based SQUID MRI system that does not require a cryogen. The SQUID detector and the superconducting gradiometer were cooled down to 3.7 K and 4.3 K, respectively. We describe the prototype design, characterization, a phantom image, and areas of further improvements needed to bring the imaging performance to parity with conventional MRI systems

  13. A cryogen-free ultralow-field superconducting quantum interference device magnetic resonance imaging system.

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2014-09-01

    Magnetic resonance imaging (MRI) at microtesla fields using superconducting quantum interference device (SQUID) detection has previously been demonstrated, and advantages have been noted. Although the ultralow-field SQUID MRI technique would not need the heavy superconducting magnet of conventional MRI systems, liquid helium required to cool the low-temperature detector still places a significant burden on its operation. We have built a prototype cryocooler-based SQUID MRI system that does not require a cryogen. The SQUID detector and the superconducting gradiometer were cooled down to 3.7 K and 4.3 K, respectively. We describe the prototype design, characterization, a phantom image, and areas of further improvements needed to bring the imaging performance to parity with conventional MRI systems.

  14. Characterization of Monomeric MnII/III/IV–Hydroxo Complexes from X- and Q-Band Dual Mode Electron Paramagnetic Resonance (EPR) Spectroscopy

    Science.gov (United States)

    Gupta, Rupal; Taguchi, Taketo; Borovik, A. S.; Hendrich, Michael P.

    2013-01-01

    Manganese–hydroxo species have been implicated in C–H bond activation performed by metalloenzymes, but the electronic properties of many of these intermediates are not well characterized. The present work presents a detailed characterization of three Mnn–OH complexes (where n = II, III, and IV) of the tris[(N′-tert-butylureaylato)-N-ethylene]aminato ([H3buea]3−) ligand using X- and Q-band dual mode electron paramagnetic resonance (EPR). Quantitative simulations for the [MnIIH3buea(OH)]2− complex demonstrated the ability to characterize similar MnII species commonly present in the resting states of manganese-containing enzymes. The spin states of the MnIII and MnIV complexes determined from EPR spectroscopy are S = 2 and 3/2, respectively, as expected for the C3 symmetry imposed by the [H3buea]3− ligand. Simulations of the spectra indicated the constant presence of two MnIV species in solutions of [MnIVH3buea(OH)] complex. The simulations of perpendicular- and parallel-mode EPR spectra allow determination of zero-field splitting and hyperfine parameters for all complexes. For the MnIII and MnIV complexes, density functional theory calculations are used to determine the isotropic Mn hyperfine values, to compare the excited electronic state energies, and to give theoretical estimates of the zero-field energy. PMID:24156406

  15. Mapping the extent of disease by multislice computed tomography, magnetic resonance imaging and sentinel node evaluation in stage I and II cervical carcinoma

    Directory of Open Access Journals (Sweden)

    Rajaram S

    2010-01-01

    Full Text Available Aims: (1 To map the extent of disease in women with stage I and II carcinoma cervix by multislice spiral computed tomography (CT, magnetic resonance imaging (MRI and sentinel nodes. (2 To assess accuracy of each modality individually and in conjunction with FIGO clinical staging. Design and Setting: Prospective, single-blind study. Departments of Obstetrics and Gynaecology, Radiodiagnosis, and Pathology, UCMS and GTBH and Division of Radiological Imaging and Bioinformatics, INMAS, Delhi. Material and Method: The study was conducted on 25 women with cervical cancer FIGO stage I and II. Each woman underwent clinical staging, multislice spiral CT and MRI which was compared to the gold-standard histopathology/cytology. The overall accuracy of each modality and improvement of clinical staging by CT/MRI were noted. Sentinel nodes were evaluated by intracervical Patent Blue V dye injection. Statistical Analysis: Sensitivity, specificity, positive and negative predictive values were calculated by 2Χ2 contingency tables. Results: The accuracy of staging by FIGO, CT and MRI was 68%, 52% and 80%, respectively. MRI and CT improved the overall accuracy of FIGO staging to 96% and 80%, respectively. Sentinel nodes were identified in 89% of patients with 91% accuracy. Conclusion: MRI emerges as the most valuable stand-alone modality improving accuracy of FIGO staging to 96%. Sentinel lymph-node evaluation appears promising in evaluating spread beyond cervix.

  16. Dynamical Processes in Open Quantum Systems from a TDDFT Perspective: Resonances and Electron Photoemission.

    Science.gov (United States)

    Larsen, Ask Hjorth; De Giovannini, Umberto; Rubio, Angel

    2016-01-01

    We present a review of different computational methods to describe time-dependent phenomena in open quantum systems and their extension to a density-functional framework. We focus the discussion on electron emission processes in atoms and molecules addressing excited-state lifetimes and dissipative processes. Initially we analyze the concept of an electronic resonance, a central concept in spectroscopy associated with a metastable state from which an electron eventually escapes (electronic lifetime). Resonances play a fundamental role in many time-dependent molecular phenomena but can be rationalized from a time-independent context in terms of scattering states. We introduce the method of complex scaling, which is used to capture resonant states as localized states in the spirit of usual bound-state methods, and work on its extension to static and time-dependent density-functional theory. In a time-dependent setting, complex scaling can be used to describe excitations in the continuum as well as wave packet dynamics leading to electron emission. This process can also be treated by using open boundary conditions which allow time-dependent simulations of emission processes without artificial reflections at the boundaries (i.e., borders of the simulation box). We compare in detail different schemes to implement open boundaries, namely transparent boundaries using Green functions, and absorbing boundaries in the form of complex absorbing potentials and mask functions. The last two are regularly used together with time-dependent density-functional theory to describe the electron emission dynamics of atoms and molecules. Finally, we discuss approaches to the calculation of energy and angle-resolved time-dependent pump-probe photoelectron spectroscopy of molecular systems.

  17. A steerable/distance enhanced penetrometer delivery system: Phase II. Topical report

    International Nuclear Information System (INIS)

    Amini, A.; Shenhar, J.; Lum, K.D.

    1996-05-01

    This report summarizes the phase II work on the Position Location Device (POLO) for penetrometers. Phase II was carried out to generate an integrated design of a full-scale steerable/distance enhanced penetrometer delivery system. Steering provides for the controlled and directional use of the penetrometer, while vibratory thrusting can provide greater penetration ability

  18. Analysis and optimisation of coupled winding in magnetic resonant wireless power transfer systems with orthogonal experiment results

    OpenAIRE

    Yudi, Xiao; Xingkui, Mao; Mao, Lin; Zhang, Zhe; Andersen, Michael A. E.

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of AC resistance and induct...

  19. Analysis and optimization of coupled windings in magnetic resonant wireless power transfer systems with orthogonal experiment method

    OpenAIRE

    Yudi, Xiao; Xingkui, Mao; Mao, Lin; Zhang, Zhe; Andersen, Michael A. E.

    2017-01-01

    The coupled magnetic resonant unit (CMRU) has great effect on the transmitting power capability and efficiency of magnetic resonant wireless power transfer system. The key objective i.e. the efficiency coefficient kQ is introduced in the design of CMRU or the coupled windings based on the mutual inductance model. Then the design method with orthogonal experiments and finite element method simulation is proposed to maximize the kQ due to low precise analytical model of ACresistance and inducta...

  20. Chip Scale Atomic Resonator Frequency Stabilization System With Ultra-Low Power Consumption for Optoelectronic Oscillators.

    Science.gov (United States)

    Zhao, Jianye; Zhang, Yaolin; Lu, Haoyuan; Hou, Dong; Zhang, Shuangyou; Wang, Zhong

    2016-07-01

    We present a long-term chip scale stabilization scheme for optoelectronic oscillators (OEOs) based on a rubidium coherent population trapping (CPT) atomic resonator. By locking a single mode of an OEO to the (85)Rb 3.035-GHz CPT resonance utilizing an improved phase-locked loop (PLL) with a PID regulator, we achieved a chip scale frequency stabilization system for the OEO. The fractional frequency stability of the stabilized OEO by overlapping Allan deviation reaches 6.2 ×10(-11) (1 s) and  ∼ 1.45 ×10 (-11) (1000 s). This scheme avoids a decrease in the extra phase noise performance induced by the electronic connection between the OEO and the microwave reference in common injection locking schemes. The total physical package of the stabilization system is [Formula: see text] and the total power consumption is 400 mW, which provides a chip scale and portable frequency stabilization approach with ultra-low power consumption for OEOs.

  1. Applications of Magnetic Resonance in Model Systems: Tumor Biology and Physiology

    Directory of Open Access Journals (Sweden)

    Robert J. Gillies

    2000-01-01

    Full Text Available A solid tumor presents a unique challenge as a system in which the dynamics of the relationship between vascularization, the physiological environment and metabolism are continually changing with growth and following treatment. Magnetic resonance imaging (MRI and magnetic resonance spectroscopy (MRS studies have demonstrated quantifiable linkages between the physiological environment, angiogenesis, vascularization and metabolism of tumors. The dynamics between these parameters continually change with tumor aggressiveness, tumor growth and during therapy and each of these can be monitored longitudinally, quantitatively and non-invasively with MRI and MRS. An important aspect of MRI and MRS studies is that techniques and findings are easily translated between systems. Hence, pre-clinical studies using cultured cells or experimental animals have a high connectivity to potential clinical utility. In the following review, leaders in the field of MR studies of basic tumor physiology using pre-clinical models have contributed individual sections according to their expertise and outlook. The following review is a cogent and timely overview of the current capabilities and state-of-the-art of MRI and MRS as applied to experimental cancers. A companion review deals with the application of MR methods to anticancer therapy.

  2. Assessment of numerical methods for the solution of fluid dynamics equations for nonlinear resonance systems

    Science.gov (United States)

    Przekwas, A. J.; Yang, H. Q.

    1989-01-01

    The capability of accurate nonlinear flow analysis of resonance systems is essential in many problems, including combustion instability. Classical numerical schemes are either too diffusive or too dispersive especially for transient problems. In the last few years, significant progress has been made in the numerical methods for flows with shocks. The objective was to assess advanced shock capturing schemes on transient flows. Several numerical schemes were tested including TVD, MUSCL, ENO, FCT, and Riemann Solver Godunov type schemes. A systematic assessment was performed on scalar transport, Burgers' and gas dynamic problems. Several shock capturing schemes are compared on fast transient resonant pipe flow problems. A system of 1-D nonlinear hyperbolic gas dynamics equations is solved to predict propagation of finite amplitude waves, the wave steepening, formation, propagation, and reflection of shocks for several hundred wave cycles. It is shown that high accuracy schemes can be used for direct, exact nonlinear analysis of combustion instability problems, preserving high harmonic energy content for long periods of time.

  3. Design and Construction of Power System for Induction Heating (IH) Cooker Using Resonant Converter

    International Nuclear Information System (INIS)

    Soe Thiri Thandar; Clement Saldanah; Win Khaing Moe

    2008-06-01

    Induction Heating (IH) systems using electromagnetic induction are developed in many industrial applications in Myanmar. Many industries have benefited from this new breakthrough by implementing induction heating for melting, hardening, and heating. Induction heating cooker is based on high frequency induction heating,electrical and electronic technologies. From the electronic point of view, induction heating cooker is composed of four parts.They are rectifier, filter, high frequency inverter, and resonant load. The purpose of this research is mainly objected to developed an induction heating cooker. The rectifier module is considered as full-bridge rectifier. The second protion of the system is a capacitive filter. The ripple components are minimized by this filter. The third is a high frequency converter to convert the constant DC to high frequency AC by switching the devices alternately. In this research, the Insulated Gate Bipolar Transistor (IGBT) will be used as a power source, and can be driven by the pulse signals from the pulse transformer circuit. In the resonant load, the power consumption is about 500W. Construction and testing has been carried out. The merits of this research work is that IH cooker can be developed because of having less energy consumption, safe, efficient, quick heating, and having efficiency of 90% or more

  4. Dobutamine stress MRI. Part II. Risk stratification with dobutamine cardiovascular magnetic resonance in patients suspected of myocardial ischemia

    International Nuclear Information System (INIS)

    Kuijpers, Dirkjan; Dijkman, Paul R.M. van; Janssen, Caroline H.C.; Vliegenthart, Rozemarijn; Zijlstra, Felix; Oudkerk, Matthijs

    2004-01-01

    The aim of this study was to determine the prognostic value of dobutamine cardiovascular magnetic resonance (CMR) in patients suspected of myocardial ischemia. Clinical data and dobutamine-CMR results were analyzed in 299 consecutive patients. Follow-up data were analyzed in categories of risk levels defined by the history of coronary artery disease and presence of rest wall motion abnormalities (RWMA). Major adverse cardiac events (MACE) as evaluated end points included cardiac death, nonfatal myocardial infarction and clinically indicated coronary revascularization. Follow-up was completed in 214 (99%) patients with a negative dobutamine-CMR study (no signs of inducible myocardial ischemia) with an average of 24 months. The patients with a negative dobutamine-CMR study and RWMA showed a significantly higher annual MACE rate (18%) than the patients without RWMA (0.56%) (P<0.001). Patients without RWMA showed an annual MACE rate of 2% when they had a history of coronary artery disease and <0.1% without a previous coronary event (P<0.001). Dobutamine-CMR showed a positive and negative predictive value of 95 and 93%, respectively. The cardiovascular occurrence-free survival rate was 96.2%. In patients suspected of myocardial ischemia, dobutamine-CMR is able to assess risk levels for coronary events with high accuracy. (orig.)

  5. A low noise photoelectric signal acquisition system applying in nuclear magnetic resonance gyroscope

    Science.gov (United States)

    Lu, Qilin; Zhang, Xian; Zhao, Xinghua; Yang, Dan; Zhou, Binquan; Hu, Zhaohui

    2017-10-01

    The nuclear magnetic resonance gyroscope serves as a new generation of strong support for the development of high-tech weapons, it solves the core problem that limits the development of the long-playing seamless navigation and positioning. In the NMR gyroscope, the output signal with atomic precession frequency is detected by the probe light, the final crucial photoelectric signal of the probe light directly decides the quality of the gyro signal. But the output signal has high sensitivity, resolution and measurement accuracy for the photoelectric detection system. In order to detect the measured signal better, this paper proposed a weak photoelectric signal rapid acquisition system, which has high SNR and the frequency of responded signal is up to 100 KHz to let the weak output signal with high frequency of the NMR gyroscope can be detected better.

  6. Stochastic resonances in a distributed genetic broadcasting system: the NFκB/IκB paradigm.

    Science.gov (United States)

    Wang, Zhipeng; Potoyan, Davit A; Wolynes, Peter G

    2018-01-01

    Gene regulatory networks must relay information from extracellular signals to downstream genes in an efficient, timely and coherent manner. Many complex functional tasks such as the immune response require system-wide broadcasting of information not to one but to many genes carrying out distinct functions whose dynamical binding and unbinding characteristics are widely distributed. In such broadcasting networks, the intended target sites are also often dwarfed in number by the even more numerous non-functional binding sites. Taking the genetic regulatory network of NF κ B as an exemplary system we explore the impact of having numerous distributed sites on the stochastic dynamics of oscillatory broadcasting genetic networks pointing out how resonances in binding cycles control the network's specificity and performance. We also show that active kinetic regulation of binding and unbinding through molecular stripping of DNA bound transcription factors can lead to a higher coherence of gene-co-expression and synchronous clearance. © 2018 The Author(s).

  7. Acoustic valley edge states in a graphene-like resonator system

    Science.gov (United States)

    Yang, Yahui; Yang, Zhaoju; Zhang, Baile

    2018-03-01

    The concept of valley physics, as inspired by the recent development in valleytronic materials, has been extended to acoustic crystals for manipulation of air-borne sound. Many valleytronic materials follow the model of a gapped graphene. Yet the previously demonstrated valley acoustic crystal adopted a mirror-symmetry-breaking mechanism, lacking a direct counterpart in condensed matter systems. In this paper, we investigate a two-dimensional (2D) periodic acoustic resonator system with inversion symmetry breaking, as an analogue of a gapped graphene monolayer. It demonstrates the quantum valley Hall topological phase for sound waves. Similar to a gapped graphene, gapless topological valley edge states can be found at a zigzag domain wall separating different domains with opposite valley Chern numbers, while an armchair domain wall hosts no gapless edge states. Our study offers a route to simulate novel valley phenomena predicted in gapped graphene and other 2D materials with classical acoustic waves.

  8. Absolute calibration of in vivo measurement systems using magnetic resonance imaging and Monte Carlo computations

    International Nuclear Information System (INIS)

    Mallett, M.W.

    1991-01-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. This method uses magnetic resonance imaging (MRI) to determine the anatomical makeup of an individual. A new MRI technique is also employed that is capable of resolving the fat and water content of the human tissue. This anatomical and biochemical information is used to model a mathematical phantom. Monte Carlo methods are then used to simulate the transport of radiation throughout the phantom. By modeling the detection equipment of the in vivo measurement system into the code, calibration factors are generated that are specific to the individual. Furthermore, this method eliminates the need for surrogate human structures in the calibration process. A demonstration of the proposed method is being performed using a fat/water matrix

  9. Stochastic resonance in an asymmetric bistable system driven by multiplicative colored noise and additive white noise

    International Nuclear Information System (INIS)

    Zhou Bingchang; Xu Wei

    2008-01-01

    The phenomenon of stochastic resonance (SR) in a bistable system driven by multiplicative colored and additive white noises and a periodic rectangular signal with a constant component is studied by using the unified colored noise approximation and the theory of signal-to-noise (SNR) in the adiabatic limit. The analytic expression of the SNR is obtained for arbitrary signal amplitude without being restricted to small amplitudes. The SNR is a non-monotonic function of intensities of multiplicative colored and additive white noises and correlation time of multiplicative colored noise, so SR exhibits in the bistable system. The effects of potential asymmetry r and correlation time τ of multiplicative colored noise on SNR are opposite. Moreover, It is more sensitive to control SR through adjusting the additive white noise intensity D than adjusting the multiplicative colored noise intensity Q

  10. Noise reduction efficiency of Helmholtz resonator in simulated channel of HVAC system

    Directory of Open Access Journals (Sweden)

    Hossein Ali Yousefi Rizi

    2014-01-01

    Conclusions: This research showed that the designed Helmholtz resonators at a certain frequency of low-frequency sound demonstrated the soundest decrease. The increase in the Helmholtz resonators′ chamber volume and their neck′s pass area are negatively associated with the rate of sound resonance. As a result, of determining the effective frequency range of the Helmholtz resonator, the designed resonator could be applied as an effective and efficient instrument of removing or decreasing noise.

  11. Non-Parametric, Closed-Loop Testing of Autonomy in Unmanned Aircraft Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase II program aims to develop new methods to support safety testing for integration of Unmanned Aircraft Systems into the National Airspace (NAS)...

  12. FINE-FILAMENT MAGNESIUM DIBORIDE SUPERCONDUCTOR WIRE FOR TURBOELECTRIC PROPULSION SYSTEMS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase II proposal overcomes technology barriers for developing highly efficient all electric aircraft systems for the future, with limited impact to the...

  13. Solid State Transmitters for Water Vapor and Ozone DIAL Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The focus of this Select Phase II program is to build and deliver laser components both for airborne water vapor and ozone DIAL systems. Specifically, Fibertek...

  14. Efficient Tm-Fiber-Pumped Ho:YLF Laser System for Coherent LIDAR Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary objective of the proposed Phase II program is to develop and deliver a ruggedized, compact single-frequency 2050-nm-laser system suitable for coherent...

  15. Stochastic resonance in FitzHugh-Nagumo neural system driven by correlated non-Gaussian noise and Gaussian noise

    Science.gov (United States)

    Guo, Yong-Feng; Xi, Bei; Wei, Fang; Tan, Jian-Guo

    2017-12-01

    In this paper, the phenomenon of stochastic resonance in FitzHugh-Nagumo (FHN) neural system driven by correlated non-Gaussian noise and Gaussian white noise is investigated. First, the analytical expression of the stationary probability distribution is derived by using the path integral approach and the unified colored noise approximation. Then, we obtain the expression of signal-to-noise ratio (SNR) by applying the theory of two-state model. The results show that the phenomena of stochastic resonance and multiple stochastic resonance appear in FHN neural system under different values of parameters. The effects of the multiplicative noise intensity D and the additive noise intensity Q on the SNR are entirely different. In addition, the discharge behavior of FHN neural system is restrained when the value of Q is smaller. But, it is conducive to enhance signal response of FHN neural system when the values of Q and D are relatively larger.

  16. 25 CFR 547.6 - What are the minimum technical standards for enrolling and enabling Class II gaming system...

    Science.gov (United States)

    2010-04-01

    ... and enabling Class II gaming system components? 547.6 Section 547.6 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM TECHNICAL STANDARDS FOR GAMING EQUIPMENT USED... enabling Class II gaming system components? (a) General requirements. Class II gaming systems shall provide...

  17. Zn(II, Mn(II and Sr(II Behavior in a Natural Carbonate Reservoir System. Part II: Impact of Geological CO2 Storage Conditions

    Directory of Open Access Journals (Sweden)

    Auffray B.

    2016-07-01

    Full Text Available Some key points still prevent the full development of geological carbon sequestration in underground formations, especially concerning the assessment of the integrity of such storage. Indeed, the consequences of gas injection on chemistry and petrophysical properties are still much discussed in the scientific community, and are still not well known at either laboratory or field scale. In this article, the results of an experimental study about the mobilization of Trace Elements (TE during CO2 injection in a reservoir are presented. The experimental conditions range from typical storage formation conditions (90 bar, supercritical CO2 to shallower conditions (60 and 30 bar, CO2 as gas phase, and consider the dissolution of the two carbonates, coupled with the sorption of an initial concentration of 10−5 M of Zn(II, and the consequent release in solution of Mn(II and Sr(II. The investigation goes beyond the sole behavior of TE in the storage conditions: it presents the specific behavior of each element with respect to the pressure and the natural carbonate considered, showing that different equilibrium concentrations are to be expected if a fluid with a given concentration of TE leaks to an upper formation. Even though sorption is evidenced, it does not balance the amount of TE released by the dissolution process. The increase in porosity is clearly evidenced as a linear function of the CO2 pressure imposed for the St-Emilion carbonate. For the Lavoux carbonate, this trend is not confirmed by the 90 bar experiment. A preferential dissolution of the bigger family of pores from the preexisting porosity is observed in one of the samples (Lavoux carbonate while the second one (St-Emilion carbonate presents a newly-formed family of pores. Both reacted samples evidence that the pore network evolves toward a tubular network type.

  18. Autonomous Ocean Sampling Networks II (AOSN-II): System Engineering and Project Coordination

    National Research Council Canada - National Science Library

    Bellingham, James

    2003-01-01

    .... Over 21 different autonomous robotic systems, three ships, an aircraft, CODAR, drifters, floats, and numerous moored observation assets were used in the field program to produce an unprecedented data...

  19. Magnetic resonance imaging characteristics in four dogs with central nervous system neosporosis.

    Science.gov (United States)

    Parzefall, Birgit; Driver, Colin J; Benigni, Livia; Davies, Emma

    2014-01-01

    Neosporosis is a polysystemic disease that can affect dogs of any age and can cause inflammation of the central nervous system. Antemortem diagnosis can be challenging, as clinical and conventional laboratory test findings are often nonspecific. A previous report described cerebellar lesions in brain MRI studies of seven dogs and proposed that these may be characteristic for central nervous system Neosporosis. The purpose of this retrospective study was to describe MRI characteristics in another group of dogs with confirmed central nervous system neosporosis and compare them with the previous report. The hospital's database was searched for dogs with confirmed central nervous system neosporosis and four observers recorded findings from each dog's MRI studies. A total of four dogs met inclusion criteria. Neurologic examination was indicative of a forebrain and cerebellar lesion in dog 2 and multifocal central nervous system disease in dogs 1, 3, and 4. Magnetic resonance imaging showed mild bilateral and symmetrical cerebellar atrophy in three of four dogs (dogs 2, 3, 4), intramedullary spinal cord changes in two dogs (dogs 3, 4) and a mesencephalic and metencephalic lesion in one dog (dog 2). Multifocal brain lesions were recognized in two dogs (dogs 1, 4) and were present in the thalamus, lentiform nucleus, centrum semiovale, internal capsule, brainstem and cortical gray matter of the frontal, parietal or temporal lobe. Findings indicated that central nervous system neosporosis may be characterized by multifocal MRI lesions as well as cerebellar involvement in dogs. © 2014 American College of Veterinary Radiology.

  20. A distributed computing system for magnetic resonance imaging: Java-based processing and binding of XML.

    Science.gov (United States)

    de Beer, R; Graveron-Demilly, D; Nastase, S; van Ormondt, D

    2004-03-01

    Recently we have developed a Java-based heterogeneous distributed computing system for the field of magnetic resonance imaging (MRI). It is a software system for embedding the various image reconstruction algorithms that we have created for handling MRI data sets with sparse sampling distributions. Since these data sets may result from multi-dimensional MRI measurements our system has to control the storage and manipulation of large amounts of data. In this paper we describe how we have employed the extensible markup language (XML) to realize this data handling in a highly structured way. To that end we have used Java packages, recently released by Sun Microsystems, to process XML documents and to compile pieces of XML code into Java classes. We have effectuated a flexible storage and manipulation approach for all kinds of data within the MRI system, such as data describing and containing multi-dimensional MRI measurements, data configuring image reconstruction methods and data representing and visualizing the various services of the system. We have found that the object-oriented approach, possible with the Java programming environment, combined with the XML technology is a convenient way of describing and handling various data streams in heterogeneous distributed computing systems.

  1. Design and implementation of an MRP-II system in electronics industry

    OpenAIRE

    Cankat, A Burç

    1991-01-01

    Ankara : Department of Industrial Engineering and the Institute of Engineering and Sciences of Bilkent Univ., 1991. Thesis (Master's) -- Bilkent University, 1991. Includes bibliographical references leaves102-104 Manufacturing Resource Planning (MRP II) system is a modern production planning and control method that is relatively new in our country. In today's competitive and continuously improving industrial scene MRP II systems play an important role in increasing produc...

  2. Systemic Hemodynamic Atherothrombotic Syndrome and Resonance Hypothesis of Blood Pressure Variability: Triggering Cardiovascular Events.

    Science.gov (United States)

    Kario, Kazuomi

    2016-07-01

    Blood pressure (BP) exhibits different variabilities and surges with different time phases, from the shortest beat-by-beat to longest yearly changes. We hypothesized that the synergistic resonance of these BP variabilites generates an extraordinarily large dynamic surge in BP and triggers cardiovascular events (the resonance hypothesis). The power of pulses is transmitted to the peripheral sites without attenuation by the large arteries, in individuals with stiffened arteries. Thus, the effect of a BP surge on cardiovascular risk would be especially exaggerated in high-risk patients with vascular disease. Based on this concept, our group recently proposed a new theory of systemic hemodynamic atherothromboltic syndrome (SHATS), a vicious cycle of hemodynamic stress and vascular disease that advances organ damage and triggers cardiovascular disease. Clinical phenotypes of SHATS are large-artery atherothombotic diseases such as stroke, coronary artery disease, and aortic and pheripheral artery disease; small-artery diseases, and microcirculation-related disease such as vascular cognitive dysfunction, heart failure, and chronic kidney disease. The careful consideration of BP variability and vascular diseases such as SHATS, and the early detection and management of SHATS, will achieve more effective individualized cardiovascular protection. In the near future, information and communication technology-based 'anticipation medicine' predicted by the changes of individual BP values could be a promising approach to achieving zero cardiovascular events.

  3. A cryogenic system for TIBER II [Tokamak Ignition/Burn Experimental Reactor

    International Nuclear Information System (INIS)

    Slack, D.S.; Kerns, J.A.

    1987-01-01

    Phase II of the Tokamak Ignition/Burn Experimental Reactor (TIBER II) study describes one option for a small, economical, next-generation tokamak [1,2]. Because of its small size, minimum shielding is used between the plasma and the toroidal-field (TF) coils. Consequently, a large cryogenic system (approximately 70 kW at 4.5 K) capable of delivering forced-flow helium is required. This paper describes a cryogenic system that meets this requirement and includes TIBER-II requirements. 3 refs

  4. The fluorescence and resonance Rayleigh scattering spectra study on the interactions of palladium (II)-Nootropic chelate with Congo red and their analytical applications.

    Science.gov (United States)

    Chen, Fang; Peng, Jingdong; Liu, Shaopu; Peng, Huanjun; Pan, Ziyu; Bu, Lingli; Xiao, Huan; Zhang, Ruiwen

    2017-04-15

    A highly sensitive detection approach of resonance Rayleigh scattering spectra (RRS) is firstly applied to analyzing nootropic drugs including piracetam (PIR) and oxiracetam (OXI). In HCl-NaAc buffer solution (pH=3.0), the OXI chelated with palladium (II) to form the chelate cation [Pd 2 ·OXI] 2+ , and then reacted with Congo red (CGR) by virtue of electrostatic attraction and hydrophobic force to form binary complex [Pd 2 ·OXI]. CGR 2 , which could result in the great enhancement of RRS. The resonance Rayleigh scattering signal was recorded at λ ex =λ em =375nm. This mixture complex not only has higher RRS, but also makes contribution to significant increase of fluorescence, and the same phenomena also were discovered in PIR. The enhanced RRS intensity is in proportion to the PIR and OXI concentration in the range of 0.03-3.0μgmL -1 , and the detection limit (DL) of RRS method for PIR and OXI is 2.3ngmL -1 and 9.7ngmL -1 . In addition, the DL of fluorescence method for PIR and OXI is 8.4μgmL -1 and 19.5μgmL -1 . Obviously, the RRS is the highly sensitive method, and the recoveries of the two kinds of nootropic drugs were range from 100.4% to 101.8.0% with RSD (n=5) from 1.1% to 3.1% by RRS method. This paper not only investigated the optimum conditions for detecting nootropics with using RRS method, but also focused on the reasons for enhancing RRS intensity and the reaction mechanism, which in order to firm and contract the resultant. Finally, The RRS method has been applied to detect nootropic drugs in human urine samples with satisfactory results. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A Wind Farm Electrical Systems Evaluation with EeFarm-II

    OpenAIRE

    Jan Pierik; Urban Axelsson; Emil Eriksson; Daniel Salomonsson; Pavol Bauer; Balazs Czech

    2010-01-01

    EeFarm-II is used to evaluate 13 different electrical systems for a 200 MW wind farm with a 100 km connection to shore. The evaluation is based on component manufacturer data of 2009. AC systems are compared to systems with DC connections inside the wind farm and DC connection to shore. Two options have the best performance for this wind farm size and distance: the AC system and the system with a DC connection to shore. EeFarm-II is a user friendly computer program for wind farm electrical an...

  6. Ca II H and K filter photometry on the uvby system. I - The standard system

    Energy Technology Data Exchange (ETDEWEB)

    Anthony-twarog, B.J.; Twarog, B.A.; Laird, J.B.; Payne, D. (Kansas, University, Lawrence (USA) Cerro Tololo Inter-American Observatory, La Serena (Chile) Bowling Green State University, OH (USA))

    1991-05-01

    A fifth filter (fwhm = 90 A) centered on Ca II H and K has been developed for use with the standard uvby system. The filter, called Ca, is designed primarily for applications to metal-poor dwarfs and red giants, regions where the uvby metallicity index, m(l), loses some sensitivity. An index, hk, is defined by replacing v in m(l) by Ca. The effects of interstellar extinction on the index are modeled and demonstrated to be modest and relatively insensitive to spectral type. Observations of V, (b-y), and hk for 163 primary standards are detailed and transformed to the standard V and (b-y) system. A qualitative analysis using only the primary standards indicates that hk is more sensitive than m(l) over the regions of interest by about a factor of 3. 58 refs.

  7. Coupled large earthquakes in the Baikal rift system: Response to bifurcations in nonlinear resonance hysteresis

    Directory of Open Access Journals (Sweden)

    Anatoly V. Klyuchevskii

    2013-11-01

    Full Text Available The current lithospheric geodynamics and tectonophysics in the Baikal rift are discussed in terms of a nonlinear oscillator with dissipation. The nonlinear oscillator model is applicable to the area because stress change shows up as quasi-periodic inharmonic oscillations at rifting attractor structures (RAS. The model is consistent with the space-time patterns of regional seismicity in which coupled large earthquakes, proximal in time but distant in space, may be a response to bifurcations in nonlinear resonance hysteresis in a system of three oscillators corresponding to the rifting attractors. The space-time distribution of coupled MLH > 5.5 events has been stable for the period of instrumental seismicity, with the largest events occurring in pairs, one shortly after another, on two ends of the rift system and with couples of smaller events in the central part of the rift. The event couples appear as peaks of earthquake ‘migration’ rate with an approximately decadal periodicity. Thus the energy accumulated at RAS is released in coupled large events by the mechanism of nonlinear oscillators with dissipation. The new knowledge, with special focus on space-time rifting attractors and bifurcations in a system of nonlinear resonance hysteresis, may be of theoretical and practical value for earthquake prediction issues. Extrapolation of the results into the nearest future indicates the probability of such a bifurcation in the region, i.e., there is growing risk of a pending M ≈ 7 coupled event to happen within a few years.

  8. Evaluation of Laser Stabilization and Imaging Systems for LCLS-II - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Barry, Matthew [Auburn Univ., AL (United States)

    2015-08-20

    By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performances when tested over fifteen hours, Guidestar-II kept the beam stable over approximately 70-110um while the MRC system kept it stable over approximately 90-100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (less than 10 minutes) without the assistance of a stability system, approximately 55um compared to approximately 70um, but the four lens configurations beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.

  9. Ca II H and K Filter Photometry on the UVBY System. II. The Catalog of Observations

    Science.gov (United States)

    Twarog, Bruce A.; Anthony-Twarog, Barbara J.

    1995-06-01

    A catalog of photometry of 1990 stars on the Caby system is presented. The sample includes stars covering an extensive range in spectral type, luminosity class, and metallicity, as well as apparent magnitude. The hk indices are on the standard system defined in Anthony-Twarog et al. (1991), while the V and (b -y) indices have been transformed to the system of Olsen (1993; hereafter referred to as 093), superseding the values in the original catalog of standard stars. Extensive comparisons to three earlier u V by catalogs with a large degree of overlap are made and the residual trends discussed. The qualitative sensitivity of the hk index as a function of temperature is illustrated for the primary spectral ranges.

  10. Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a (60)Co Magnetic Resonance Image Guidance Radiation Therapy System

    DEFF Research Database (Denmark)

    Wooten, H Omar; Green, Olga; Yang, Min

    2015-01-01

    PURPOSE: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating (60)Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. METHODS AND MATERIALS...

  11. Anti-saturation system for surface nuclear magnetic resonance in efficient groundwater detection

    Science.gov (United States)

    Lin, Jun; Zhang, Yang; Yang, Yujing; Sun, Yong; Lin, Tingting

    2017-06-01

    Compared to other geophysical techniques, the surface nuclear magnetic resonance (SNMR) method could provide unique insights into the hydrologic properties of groundwater in the subsurface. However, the SNMR signal is in the order of nanovolts (10-9 V), and the complex environmental noise, i.e., the spike and the harmony noise (10-4 V), can reach up to 105 times the signal amplitude. Saturation of the amplifier is therefore a serious problem in current SNMR systems. In this study, we propose an anti-saturation method based on an instantaneous floating-point amplifier. The gain of a programmable amplifier is controlled by the value of the input signal. A regulating speed of 50 kS/s is thus achieved to satisfy the self-adaptive adjustment of the real-time SNMR system, which replaces the original man-made setting gain. A large dynamic range of 192.65 dB with a 24-bit high speed analog-digital converter module is then implemented. Compared to traditional SNMR instruments, whose magnification factor is fixed during the experiment, our system can effectively inhibit the distortion of the SNMR signal in both laboratory and field settings. Furthermore, an improved SNR, which is realized by the real-time SNMR system, enables the accurate inversion of the aquifer. Our study broadens the applicability of SNMR systems to use in and around developed areas.

  12. Fluorescence resonance energy transfer in a binary organic nanoparticle system and its application.

    Science.gov (United States)

    Wu, Meng; Xu, Xinjun; Wang, Jinshan; Li, Lidong

    2015-04-22

    Fluorescent organic nanoparticles have a much better photostability than molecule-based probes. Here, we report a simple strategy to detect chemicals and biomolecules by a binary nanoparticle system based on fluorescence resonance energy transfer (FRET). Poly(9,9-di-n-octylfluorenyl-2,7-diyl) (PFO, energy donor) and poly [2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV, energy acceptor) are utilized to prepare the binary nanoparticle system through a reprecipitation method. Since the FRET process is strongly distance-dependent, a change in the interparticle distance between the two kinds of nanoparticles after introduction of analytes will alter the FRET efficiency. The response of the binary nanoparticle system to cationic polyelectrolytes was investigated by monitoring the FRET efficiency from PFO to MEH-PPV nanoparticles and the fluorescence color of the nanoparticle solutions. Furthermore, the cationic polyelectrolyte pretreated binary nanoparticle system can be used to detect DNA by desorption of nanoparticles from the polyelectrolyte's chains and the detection concentration can go down to 10(-14) M. Thus, the binary nanoparticle system shows great promise for applications in chemical sensing or biosensing.

  13. Distributed Rocket Engine Testing Health Monitoring System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  14. Magnesium Hall Thruster for Solar System Exploration, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation being developed in this program is a Mg Hall Effect Thruster system that would open the door for In-Situ Resource Utilization based solar system...

  15. MOIDSS?- Mobile Online Intelligent Decision Support System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — GRID has had a successfully completed Phase I 'Mobile Online Intelligent Decision Support System' (MOIDSS). The system developed into a total solution that supports...

  16. Brake System Design Optimization. Volume II : Supplemental Data.

    Science.gov (United States)

    1981-06-01

    Existing freight car braking systems, components, and subsystems are characterized both physically and functionally, and life-cycle costs are examined. Potential improvements to existing systems previously proposed or available are identified and des...

  17. Online Real-Time Tribology Failure Detection System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Under NASA Phase I funding, we have developed a system for the ball bearing fault detection and identification. Our system can effectively identify multiple fault...

  18. Integral Radiators for Next Generation Thermal Control Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Integral radiators integrate the primary structural system and the thermal rejection system into a dual function subsystem allowing for reduced weight. The design of...

  19. An Uninhabited Aerial System Safety Analysis Model (USAM), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The National Airspace System (NAS) in the United States will become a complex array of commercial and general aviation aircraft, unmanned aircraft systems, reusable...

  20. Advanced Microgravity Compatible, Integrated Laundry System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — An Advanced Microgravity Compatible, Integrated laundry System (AMCILS) is proposed that uses a two phase water / water vapor system to allow good agitation of...