WorldWideScience

Sample records for system energy savings

  1. Energy saving synergies in national energy systems

    DEFF Research Database (Denmark)

    Thellufsen, Jakob Zinck; Lund, Henrik

    2015-01-01

    In the transition towards a 100% renewable energy system, energy savings are essential. The possibility of energy savings through conservation or efficiency increases can be identified in, for instance, the heating and electricity sectors, in industry, and in transport. Several studies point...... to various optimal levels of savings in the different sectors of the energy system. However, these studies do not investigate the idea of energy savings being system dependent. This paper argues that such system dependency is critical to understand, as it does not make sense to analyse an energy saving...... without taking into account the actual benefit of the saving in relation to the energy system. The study therefore identifies a need to understand how saving methods may interact with each other and the system in which they are conducted. By using energy system analysis to do hourly simulation...

  2. Models of Energy Saving Systems

    DEFF Research Database (Denmark)

    Nørgård, Jørgen Stig

    1999-01-01

    The paper first describes the concepts and methods around energy saving, such as energy chain, energy services, end-use technologies, secondary energy, etc. Next are discussed the problems of defining and adding energy services and hence end-use energy efficiency or intensity. A section is devoted...... to what is termed lifestyle efficiency, including the cultural values and the ability of the economy to provide the services wanted. As explained, integrated resource planning with its optimizing the whole energy chain cannot be combined with sub-optimizing part of it, for instance the supply technology...... only. The need for including also the economic policy in the energy planning is illustrated with what is termed the efficiency pittfall. This points towards difficulties in imaging an integrated resource planning combined with a liberalized market. The three variable parameters, population, energy...

  3. An energy saving system for hospital laundries

    Energy Technology Data Exchange (ETDEWEB)

    Katsanis, J.S.; Tsarabaris, P.T.; Polykrati, A.D.; Proios, A.N. [National Technical Univ. of Athens, Athens (Greece). School of Electrical and Computer Engineering; Koufakis, E.I. [Public Power Corp. S.A., Crete (Greece)

    2009-07-01

    Hospital laundries are one of the largest consumers of water and electrical and thermal energy. This paper examined the energy savings achieved by a system using the hot wastewater from the washing process. Hospital laundries consume thermal energy using steam, which is produced in boilers by burning diesel oil or natural gas. Electrical energy for the mechanical drives, ventilation and also the lighting required in the laundry area are big consumers of energy. The paper presented the proposed system and discussed the parameters of the system and system dimensioning. The paper also provided and discussed an interpretation of steam and energy savings. The proposed system was considered to be economically viable, simple in its construction, installation and operation. From the application of the suggested system, the cost savings resulted in a satisfactory payback period for the capital invested of approximately three to five years. 14 refs., 4 tabs., 2 figs.

  4. Energy Saving and Efficient Energy Use By Power Electronic Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Wang, Huai; Davari, Pooya

    2017-01-01

    energy in different applications. This chapter will give an overview of challenges and possibilities in terms of energy saving and also energy efficient use. This includes a discussion on high efficiency power electronics devices and the systems they are used for energy loss reduction. The key enabling......In the development of the modern society, one of the key factors is to save energy in order to become more independent of other energy resources. Two important approaches can be taken—one is to change behavior and thereby save energy—the second one is to develop new technology which is able to save...... technologies are power electronics, Information and Communication Technology (ICT) as well as systems to carry the electrical energy through power transmission, conversion and distribution. A couple of examples will be given to demonstrate the energy saving possibilities by power electronics systems...

  5. Energy Savings for Solar Heating Systems

    DEFF Research Database (Denmark)

    Thür, Alexander; Furbo, Simon; Shah, Louise Jivan

    2006-01-01

    showed a good degree of similarity. With the boiler model, various simulations of solar domestic hot water heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal...... system. For some conditions the fuel reduction can be up to the double of the solar gain due to a strong increase of the system efficiency. As the monitored boilers were not older than 3 years, it can be assumed that the saving potential with older boilers could be even higher than calculated...

  6. Save Energy: Save Money!

    Science.gov (United States)

    Eccli, Eugene; And Others

    This publication is a collection of inexpensive energy saving tips and home improvements for home owners, particularly in low-income areas or in older homes. Section titles are: (1) Keeping Warm; (2) Getting Heat Where You Need It; (3) Using the Sun; (4) Furnaces, Stoves, and Fireplaces; (5) Insulation and Other Energy Needs; (6) Do-It-Yourself…

  7. Energy savings for solar heating systems; Solvarmeanlaegs energibesparelser

    Energy Technology Data Exchange (ETDEWEB)

    Furbo, S.; Fan, J.

    2011-01-15

    Energy savings for a number of new solar heating systems in one family houses have been determined by means of information on the energy consumption of the houses before and after installation of the solar heating systems. The investigated solar heating systems are marketed by Velux Danmark A/S, Sonnnenkraft Scandinavia A/S and Batec Solvarme A/S. Solar domestic hot water systems as well as solar combi systems are included in the investigations The houses have different auxiliary energy supply systems: Natural gas boilers, oil fired burners, electrical heating and district heating. Some of the houses have a second auxiliary energy supply system. The collector areas vary from 1.83 m{sup 2} to 9.28 m{sup 2}. Some of the solar heating systems are based on energy units with a new integrated natural gas boiler and a heat storage for the solar heating system. The existing energy systems in the houses are for most of the houses used as the auxiliary energy systems for the solar heating systems. The yearly energy savings for the houses where the only change is the installation of the solar heating system vary from 300 kWh per m{sup 2} solar collector to 1300 kWh per m{sup 2} solar collector. The average yearly energy savings is about 670 kWh per m{sup 2} solar collector for these solar heating systems. The energy savings per m{sup 2} solar collector are not influenced by the solar heating system type, the company marketing the system, the auxiliary energy supply system, the collector area, the collector tilt, the collector azimuth, the energy consumption of the house or the location of the house. The yearly energy savings for the houses with solar heating systems based on energy units including a new natural gas boiler vary from 790 kWh per m{sup 2} solar collector to 2090 kWh per m{sup 2} solar collector. The average yearly energy savings is about 1520 kWh per m{sup 2} solar collector for these solar heating systems. The energy savings per m{sup 2} solar collector for

  8. Opportunities of energy saving in lighting systems for public buildings

    Directory of Open Access Journals (Sweden)

    Ayman Abd El-khalek

    2017-03-01

    Full Text Available The lighting system provides many options for cost-effective energy saving with low or no inconvenience. Lighting improvements are excellent investments in most public buildings, it is usually cost-effective to address because lighting improvements are often easier to make than many process upgrades.For public buildings, the easy no and low cost options to help save money and improve the energy performance are:Understand energy use.Identify optionsPrioritize actionsMake the changes and measure the savings.Continue managing energy efficiency.The challenge is to retrofit traditional lamps with LED lamps of good quality. The benefits of LED light bulbs are long-lasting, durable, cool, mercury free, more efficient, and cost effective.The light Emitting Diode (LED bulb uses a semiconductor as its light source, and is currently one of the most energy efficient and quickly developing types of bulbs for lighting. LEDs increasingly are being purchased to replace traditional bulbs. LEDs are relatively more expensive than other types of bulbs, but are very cost-effective because they use only a fraction of electricity of traditional lighting methods nd can last for longer.Benchmarking guides decision makers to policies aimed at the energy sector through better understanding of energy consumption trends nationwide, e.g.: energy price, moderating, peak demand, and encouraging sectors, low energy expansions.The “Improving Energy Efficiency Project of Lighting and Appliances” carried out energy audits and implemented opportunities of energy saving in lighting for different type of public buildings.To rationalize the use of energy by giving guidelines to consumers, the IEEL&A project prepared some brochures.This paper leads with the results of case studies as energy audits, opportunities in lighting systems, energy saving and CO2 reduction.

  9. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    One of the important issues related to the implementation of future sustainable smart energy systems based on renewable energy sources is the heating of buildings. Especially, when it comes to long‐term investment in savings and heating infrastructures it is essential to identify long‐term least......‐cost strategies. With Denmark as a case, this paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used. Based on a concrete proposal to implement the Danish governmental long...... that a least‐cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps. Keywords: Energy Efficiency, Renewable energy, Heating strategy, Heat savings, District heating, Smart energy...

  10. Energy saving certificates

    International Nuclear Information System (INIS)

    2005-11-01

    The French ministry of economy, finances and industry and the French agency of environment and energy mastery (Ademe) have organized on November 8, 2005, a colloquium for the presentation of the energy saving certificates, a new tool to oblige the energy suppliers to encourage their clients to make energy savings. This document gathers the transparencies presented at this colloquium about the following topics: state-of-the-art and presentation of the energy saving certificates system: presentation of the EEC system, presentation of the EEC standard operations; the energy saving certificates in Europe today: energy efficiency commitment in UK, Italian white certificate scheme, perspectives of the different European systems. (J.S.)

  11. Energy Savings for Solar Heating Systems

    DEFF Research Database (Denmark)

    Thür, Alexander; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    , various simulations of solar heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal system. For some conditions the fuel reduction can be up to the double of the solar...

  12. Energy saving and recovery measures in integrated urban water systems

    Science.gov (United States)

    Freni, Gabriele; Sambito, Mariacrocetta

    2017-11-01

    The present paper describes different energy production, recovery and saving measures which can be applied in an integrated urban water system. Production measures are often based on the installation of photovoltaic systems; the recovery measures are commonly based on hydraulic turbines, exploiting the available pressure potential to produce energy; saving measures are based on substitution of old pumps with higher efficiency ones. The possibility of substituting some of the pipes of the water supply system can be also considered in a recovery scenario in order to reduce leakages and recovery part of the energy needed for water transport and treatment. The reduction of water losses can be obtained through the Active Leakage Control (ALC) strategies resulting in a reduction in energy consumption and in environmental impact. Measures were applied to a real case study to tested it the efficiency, i.e., the integrated urban water system of the Palermo metropolitan area in Sicily (Italy).

  13. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    2014-01-01

    This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish...

  14. Matrix converter applied to energy saving for street lighting systems

    OpenAIRE

    Román Lumbreras, Manuel; Velasco Quesada, Guillermo; Conesa Roca, Alfons

    2010-01-01

    This work presents a three-phase AC-AC converter, with independent phase control, based on matrix-converter structure. This converter is applied to electrical energy saving on the public lighting systems by means of regulation and control of the voltage applied to the lamps. The developed converter represents a technological improvement with respect to the traditional systems based on an autotransformer: it reduces system cost and volume, and increases lamps lifetime.

  15. Potential Energy Savings in Refrigeration Systems Using Optimal Setpoints

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Slot; Thybo, Claus

    2004-01-01

    Energy efficiency of refrigeration systems has gradually been improved with help of control schemes utilizing the more flexible components. This paper proposes an approach in line with this trend, where a suboptimal condenser pressure is found in order to minimize the energy consumption....... The objective is to give an idea of how this optimization scheme works as well as to show what amount of energy it is possible to save. A steady state model of a simple refrigeration system will be used as a basis for the optimization....

  16. Heat Saving Strategies in Sustainable Smart Energy Systems

    Directory of Open Access Journals (Sweden)

    Henrik Lund

    2014-06-01

    Full Text Available This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps.

  17. Compressed air systems. A guidebook on energy and cost savings

    Energy Technology Data Exchange (ETDEWEB)

    1984-03-30

    This guidebook shows how energy can be saved in compressed air systems. It discusses basic compressed air systems which are typical of those found in industry and describes them and the engineering practices behind them. Energy conservation recommendations follow. These recommendations cover equipment selection, design, maintenance, and operation. Included is information which will help the reader to make economic evaluations of various engineering and equipment alternatives as they affect operations and costs. The appendices include some modern computer based approaches to predicting pressure drop for designing compressed air distribution systems. Also included is a bibliography providing leads for further and more detailed technical information on these and related subjects.

  18. A New Hybrid Bathroom System Based on Energy Saving Concept

    Directory of Open Access Journals (Sweden)

    Cui Bo-wen

    2016-01-01

    Full Text Available Based on the characteristics of hot water supply in bathroom, this article proposes a new hybrid energy hot water supply system. The programmable logic controller(PLC as the master controller was adopted in this system, which could automatically detect and storage main thermal physical of the system, such as temperature, water level, solar radiation intensity, power consumption and so on. The active thermal utilization technology of solar energy, air-source heat pump technology, solar energy intensive natural ventilation technology and low temperature hot water floor radiant heating technology were organically integrated in this system, which has the advantages of energy conservation and environment protection, high automation, safe and reliable operation, etc. At the same time, it can make good use of electric power cost between on-peak and off-peak, and promote the optimal allocation of power resources and reduce the cost, which can achieve the goal of intelligent control and energy saving.

  19. ASSESSMENT OF ENERGY SAVING IN WASTE RECYCLING USING SYSTEM DYNAMICS

    Directory of Open Access Journals (Sweden)

    Eugênio de Oliveira Simonetto

    2013-06-01

    Full Text Available Recycling is a topic of great importance in integrated waste management, evidence of this is verified in the National Policy of Solid Waste, decreed in 2010, where it is considered one of the priorities. In this article is presented a computer simulation model, since their development until its validation, which aims to support environmental managers in their decisions regarding the definition and / or maintenance of solid waste policies recycling, as well as evaluating the benefits of process in the environment (in this article we evaluated the energy savings. For the model development was considered: the rate of natural population growth (births and deaths, percentage of solid waste recycled (for each type of material, gravimetric composition of the material in the total waste generated, the amount of waste generated per inhabitant and energy savings caused by each distinct type of material. Through the model results generated, end users (environmental managers thereof may, for example, set incentives to reduce the total generation of solid waste, produce campaigns enhancing reuse and recycling and to assess the relative benefits of energy savings caused by recycling. Model validation was through analysis of future scenarios for a given municipality in southern Brazil. For modeling and system validation was used Vensim from Ventana Systems.

  20. Energy Saving and Efficient Energy Use By Power Electronic Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Wang, Huai; Davari, Pooya

    2017-01-01

    , such as in the applications of adjustable speed drives and solid-state lighting systems. Power electronics gives also a high flexibility when renewable power production is introduced to electrical energy systems. Future research opportunities and challenges will finally be discussed....

  1. Health Externalities and Heat savings in Energy System Modelling

    DEFF Research Database (Denmark)

    Zvingilaite, Erika

    of pollutant release. Furthermore, combustion of all fuels, including biomass, results in emissions of the local/regionalair pollutants. Impacts on human health are the most significant damage category of the air pollution in Europe today. This PhD study focuses on human health impacts of local/regional air...... and technologies, more remote location of energy plants and by reducing energy consumption. Considerable technical potential for energy demand reduction exists, particularly in buildings. In countries with cold climate, such as Denmark, energy demand for heating of buildings accounts for a significant share...... optimisation model Balmorel. Consequently, in the model, cost effective levels of heat savings can be identified and analysed in the context of the optimal heat and power system. The results of the PhD study indicate that locationof buildings is an important factor for an overall optimal penetration of heat...

  2. Studies on energy system for an energy-saving society; Sho energy gata shakai ni okeru energy system kento

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The system to which new energy technology and energy saving technology were introduced was constructed for case studies of urban areas including core cities and the peripheral areas, and the quantitative analysis was conducted on environmental effects, etc. In the energy supply system model, the following element technologies were all considered: cogeneration system, sewage water heat, river water heat, the photovoltaic power generation, energy storage/heat storage/cold heat storage, adsorption type refrigerator, etc. Also considered were power interchange between clusters, system power buying/power selling, heat interchange or no heat interchange, etc. As a result, it was found that when constructing the energy system which synthetically takes into account thermoelectric ratios, rates of simultaneous loads, ratios of daytime/nighttime in the energy supply and demand in the urban area, the energy saving effect multiplicatively increases, and the energy system using cogeneration and unused energy such as refuse and sewage in the urban area and river water brings an energy saving effect of 32% especially in the concentrated cluster. 83 figs., 45 tabs.

  3. Energy performance and energy saving of life-support systems in ...

    African Journals Online (AJOL)

    The contemporary automation systems of buildings ensure the most efficient control automation for heating, ventilation, lighting, hot water supply systems. This leads to significant increase of operation efficiency and reduction of energy costs. The integrated energy saving processes and functions are optimized depending ...

  4. Evaluating energy saving system of data centers based on AHP and fuzzy comprehensive evaluation model

    Science.gov (United States)

    Jiang, Yingni

    2018-03-01

    Due to the high energy consumption of communication, energy saving of data centers must be enforced. But the lack of evaluation mechanisms has restrained the process on energy saving construction of data centers. In this paper, energy saving evaluation index system of data centers was constructed on the basis of clarifying the influence factors. Based on the evaluation index system, analytical hierarchy process was used to determine the weights of the evaluation indexes. Subsequently, a three-grade fuzzy comprehensive evaluation model was constructed to evaluate the energy saving system of data centers.

  5. Fossil energy savings potential of sugar cane bio-energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thu Lan T. [Department of Agroecology, Aarhus University, Tjele (Denmark); The Joint Graduate School of Energy and Environment, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Hermansen, John E. [Department of Agroecology, Aarhus University, Tjele (Denmark); Sagisaka, Masayuki [Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology, Tsukuba (Japan)

    2009-11-15

    One important rationale for bio-energy systems is their potential to save fossil energy. Converting a conventional sugar mill into a bio-energy process plant would contribute to fossil energy savings via the extraction of renewable electricity and ethanol substituting for fossil electricity and gasoline, respectively. This paper takes a closer look at the Thai sugar industry and examines two practical approaches that will enhance fossil energy savings. The first one addresses an efficient extraction of energy in the form of electricity from the excess bagasse and cane trash. The second while proposing to convert molasses or sugar cane to ethanol stresses the use of bagasse as well as distillery spent wash to replace coal in meeting ethanol plants' energy needs. The savings potential achieved with extracting ethanol from surplus sugar versus current practice in sugar industry in Thailand amounts to 15 million barrels of oil a year. Whether the saving benefits could be fully realized, however, depends on how well the potential land use change resulting from an expansion of ethanol production is managed. The results presented serve as a useful guidance to formulate strategies that enable optimum utilization of biomass as an energy source. (author)

  6. Heat savings in energy systems with substantial distributed generation

    DEFF Research Database (Denmark)

    Østergaard, PA

    2003-01-01

    . A lowered district heating demand and thereby lowered CHP-bound electricity generation would appear to increase the possibility of integration wind power but due to the ancillary services supplied by CHP plants, the situation is in fact the opposite. Heat savings may not be technically feasible......, if a certain production is required regardless of whether over-all electricity generation is sufficient. This article analyses this and although heat savings do have a negative impact on the amount of wind power the system may integrate a given moment in certain cases, associated fuel savings are notable......In Denmark, the integration of wind power is affected by a large amount of cogeneration of heat and power. With ancillary services supplied by large-scale condensation and combined heat and power (CHP) plants, a certain degree of large-scale generation is required regardless of momentary wind input...

  7. The Energy Savings and Environmental Benefits for Small and Medium Enterprises by Cloud Energy Management System

    Directory of Open Access Journals (Sweden)

    Yen-Chieh Tseng

    2016-06-01

    Full Text Available Small and medium enterprises (SMES play an important role in Taiwan’s economy. The reduction of energy costs and carbon dioxide (CO2 emissions are critical to preserving the environment. This paper uses the experimental results from 65 sites, gathered over two years since 2012, to determine how the integration of Internet communication, cloud computing technologies and a cloud energy management service (cloud EMS can reduce energy consumption by cost-effective means. The EMS has three levels: infrastructure as a service (IaaS, platform as a service (PaaS and software as a service (SaaS. Working jointly with ChungHwa Telecom, Taiwan’s leading telecom service provider, data from detection devices, control devices, air-conditioning and lighting systems are all uploaded to a cloud EMS platform, to give a so called intelligent energy management network application service platform (IEN-ASP. Various energy saving management functions are developed using this platform: (1 air conditioning optimization; (2 lighting system optimization; (3 scheduling control; (4 power billing control and (5 occupancy detection and timing control. Using the international performance measurement and verification protocol (IPMVP, the energy used at the test sites, before and after the use of the IEN-ASP, are compared to calculate the energy saved. The experimental results show that there is an average energy saving of 5724 kWh per year, which represents a saving ratio of 5.84%. This translates to a total reduction in CO2 emissions of 9,926,829 kg per year. Using the data collected, a regression model is used to demonstrate the correlation between the power that is consumed, the energy that is saved and the area of the sites. Another interesting result is that, if the experimental sites are maintained by experienced electricians or other personnel and EMS protocols are followed, the energy saving can be as great as 6.59%.

  8. Multi-fuctional heat recovery systems. Really energy saving; Multifunktionale Waermerueckgewinnung. Wie man wirklich Energie spart

    Energy Technology Data Exchange (ETDEWEB)

    Schilling, Heinz [SEW Systemtechnik fuer Energierecycling und Waermeflussbegrenzung GmbH, Kempen (Germany)

    2009-10-15

    An energy saving leeds only to a correct optimized operation, if a demand-oriented total design is integrated into the building. In special for air-conditioning energy saving measures are presented and essential criteria named, to save in fact effectively, efficiently, reliably and profitably energy and enhance simultanously user quality. (orig./GL)

  9. Energy Saving in Data Processing and Communication Systems

    Directory of Open Access Journals (Sweden)

    Giuseppe Iazeolla

    2014-01-01

    Full Text Available The power management of ICT systems, that is, data processing (Dp and telecommunication (Tlc systems, is becoming a relevant problem in economical terms. Dp systems totalize millions of servers and associated subsystems (processors, monitors, storage devices, etc. all over the world that need to be electrically powered. Dp systems are also used in the government of Tlc systems, which, besides requiring Dp electrical power, also require Tlc-specific power, both for mobile networks (with their cell-phone towers and associated subsystems: base stations, subscriber stations, switching nodes, etc. and for wired networks (with their routers, gateways, switches, etc.. ICT research is thus expected to investigate into methods to reduce Dp- and Tlc-specific power consumption. However, saving power may turn into waste of performance, in other words, into waste of ICT quality of service (QoS. This paper investigates the Dp and Tlc power management policies that look at compromises between power saving and QoS.

  10. The influence of an estimated energy saving due to natural ventilation on the Mexican energy system

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    This article shows the impacts of the extensive use of NV (natural ventilation) in the Mexican residential sector on the Mexican energy system. By integrating a thermal-airflow simulation programme with an energy systems analysis model, the impact on the Mexican energy system of replacing air...... conditioning, in particular, with natural ventilation to cool residential buildings is determined. It is shown that when, as in Mexico, there is a relatively simple connection between supply and electricity demand, NV creates savings which could be used to reduce either the fossil-fuel-based generation...

  11. Ultra high benefits system for electric energy saving and management of lighting energy in buildings

    International Nuclear Information System (INIS)

    Fathabadi, Hassan

    2014-01-01

    Highlights: • Presenting a novel multi channel smart system to manage lighting energy in buildings. • Saving considerable electric energy which is converted to lighting in buildings. • Providing desired constant and adjustable luminance for each location in buildings. • Capability of working with all AC electric power sources. • To automatically control and manage lighting energy in buildings. - Abstract: This paper presents a smart system, including a multi channel dimmer and a central process unit (CPU) together with an exact multi channel feedback mechanism, which automatically regulates and manages lighting in buildings. Based on a multi channel luminance feedback, a high benefits technique is utilized to convert the electric energy to lighting energy. Saving a lot of the electric energy which should be converted to lighting energy in buildings, managing the lighting energy in buildings, providing desired constant and adjustable luminance for each room (location), and the capability of working with all AC electric power sources regardless of frequency and voltage amplitude are some advantages of using the proposed system and technique, thus it will be widely used in buildings. An experimental prototype of the proposed smart system has been constructed to validate the theoretical results and to carry out the experimental tests. Experimental results earned by utilizing the proposed smart system in a sample building are presented to prove the benefits of using the system. The experimental results explicitly show a considerable electric energy saving (about 27%) in the sample building while the proposed system has provided desired constant and adjustable luminance for each location of the building

  12. Energy saving report; Energispareredegoerelse

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-05-01

    Making the energy consumption more efficient in Denmark by means of energy saving are connected to the Danish government's overall National Growth Strategy. A reduced consumption of energy as a result of economic attractive energy saving initiatives leads to reduced energy costs and consequently an improvement of Denmark's competitive power. Furthermore, reducing the energy consumption decreases the vulnerability towards rising energy prices, and the security of supplies is increased. Finally energy conservation serves as a means of reducing environmental impact from the energy sector. Energy consumption is not damaging to the environment in itself, however, to the extent that energy consumption causes negative impact on the environment, e.g. through discharge of environmentally damaging substances generated during energy production, a reduction of the energy consumption will benefit the environment. Energy saving in itself does not lead to a decrease in CO{sub 2} emission in Denmark unless it is accompanied by an adjustment of CO{sub 2} quotas on production of electricity. The Danish Government emphasizes that the energy saving efforts are cost-effective both for the society and for the consumers. The energy saving report contains an updated projection of the Danish energy consumption and an evaluation of the impacts of the energy saving efforts. The impacts of more effective end use of energy are described, and an account of the barriers preventing the realization of a number of potential economic attractive energy saving initiatives is made. Finally the energy saving report presents a number of proposals for new energy saving initiatives. (BA)

  13. Design of energy saving monitoring system on isothermal oilless lubricated air compressor

    Science.gov (United States)

    Ma, S. N.; Liu, Q.; Xu, B. L.; Liu, Y.; Hu, F.

    2017-10-01

    This design introduces a kind of STM32F051C8T6 circuit monitoring system which is based on the ARM core. According to the operating principle of air compressor, the reduction of temperature and current is converted to save electricity and directly displayed, save electricity information stored at the same time, to achieve real-time monitoring air compressor energy saving effect in the process of operation.

  14. Measuring industrial energy savings

    International Nuclear Information System (INIS)

    Kelly Kissock, J.; Eger, Carl

    2008-01-01

    Accurate measurement of energy savings from industrial energy efficiency projects can reduce uncertainty about the efficacy of the projects, guide the selection of future projects, improve future estimates of expected savings, promote financing of energy efficiency projects through shared-savings agreements, and improve utilization of capital resources. Many efforts to measure industrial energy savings, or simply track progress toward efficiency goals, have had difficulty incorporating changing weather and production, which are frequently major drivers of plant energy use. This paper presents a general method for measuring plant-wide industrial energy savings that takes into account changing weather and production between the pre and post-retrofit periods. In addition, the method can disaggregate savings into components, which provides additional resolution for understanding the effectiveness of individual projects when several projects are implemented together. The method uses multivariable piece-wise regression models to characterize baseline energy use, and disaggregates savings by taking the total derivative of the energy use equation. Although the method incorporates search techniques, multi-variable least-squares regression and calculus, it is easily implemented using data analysis software, and can use readily available temperature, production and utility billing data. This is important, since more complicated methods may be too complex for widespread use. The method is demonstrated using case studies of actual energy assessments. The case studies demonstrate the importance of adjusting for weather and production between the pre- and post-retrofit periods, how plant-wide savings can be disaggregated to evaluate the effectiveness of individual retrofits, how the method can identify the time-dependence of savings, and limitations of engineering models when used to estimate future savings

  15. Fan System Optimization Improves Ventilation and Saves Energy at a Computer Chip Manufacturer

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-01-01

    This case study describes an optimization project implemented on a fan system at Ash Grove Cement Company, which led to annual energy and maintenance savings of $16,000 and 175,000 kilowatt-hours (kWh).

  16. Energy savings from operation and maintenance training for apartment boiler heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Tooze, David

    1992-02-01

    The Portland Energy Office provided operation and maintenance (O M) training to the operators of boiler heating systems for ten low-income apartment complexes in the Fall of 1990. This study tracked energy usage before and after O M training to see if savings occurred. Training was provided on both weatherized and non-weatherized apartments to find out if weatherization impacted the amount of O M savings to be obtained. Also, energy savings from the O M training and building shell weatherization are compared. The O M training averaged about four hours per building. Content was adjusted at each site to match needs of the boiler and operator. The Energy Office also provided a boiler tune-up by a service technician. The training stressed low-cost and no-cost measures which operators could either do themselves or hire service help to implement. It also emphasized boiler safety. Nine of the ten apartment complexes in the study used less energy per heating degree-day after the O M help. Average savings were 10%. Four apartments chosen randomly as controls had negative savings; they used slightly more energy during the same post-O M time frame. Weatherized and unweatherized apartments showed similar savings after the O M help, 10% and 11% percent respectively. Savings from weatherization of six of the apartments in the winter of 1988--1989 were also measured. A low average of only 4% was observed, reflecting negative savings in two buildings.

  17. Another Approach to Save Energy in OFDM Systems

    NARCIS (Netherlands)

    Shao, X.; Slump, Cornelis H.

    2010-01-01

    In this paper, we propose an energy-efficient error correction scheme to lower the power consumption of the ADCs in the OFDM system. The proposed opportunistic error correction scheme is based on resolution adaptive ADCs and fountain codes. The key idea is to reduce the dynamic range of the channel

  18. Heat savings in energy systems with substantial distributed generation

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2004-01-01

    The integration of flutuating wind power is an important issue for the future development of sustainable energy systems. In Denmark, the integration is affected by a large amount of cogeneration of heat and power. This gives possibilities as well as sets restraints. The paper shows...... that with ancillary services supplied by large-scale condensation and CHP-plants, a certain degree of large-scale generation is required regardless of momentary wind input....

  19. Potential energy savings using dynamically optimizing control in refrigeration systems under daily variations in ambient temperature

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Sloth; Thybo, Claus; Wisniewski, Rafal

    2007-01-01

    The objective of this study is to investigate the energy saving potential for refrigeration systems by refrigeration more at the colder night time than at the warmer day time. The potential is evaluated using an optimal control policy and illustrated on a simulation example. The results show...... that the significant potential savings depends on two system parameters and the variation of the outdoor temperature. The system dependency is illustrated in a parameter study....

  20. Energy saving house utilizing photovoltaic system. 3; Taiyoko hatsuden wo donyushita sho energy jutaku. 3

    Energy Technology Data Exchange (ETDEWEB)

    Itsumi, J. [Kumamoto Institute of Technology, Kumamoto (Japan)

    1997-11-25

    Various measurements are conducted in an energy-efficient house equipped with a photovoltaic power generation system and actually lived in by people, and matching between the household load and photovoltaic power generation, and the consumption of power, are examined. As the result investigation of power consumption in the house, it is found that 13.31kWh is consumed in the daytime in winter, and 14.15kWh in summer. Thirty-two 153W modules are used, and they produce 12.74kWh in four hours on a fine summer day, which amount nearly satisfies the demand of the household. As for the records during a year beginning in May, 1996, it is found that an annual amount of 4326kWh was generated, with 68% being surplus and 32% consumed for the household. Details of the household consumption were that 49.2% was consumed for house heating and cooling and 34.1% for cooking, the two in total occupying more than 80% of the whole household consumption. Energy-saving behavior is evaluated by comparing the energy-efficient house with some ordinary residential houses in Kumamoto City, and it is found that there is a yearly difference of 104,310 yen in electricity bill or 47% in energy saving effect. 5 refs., 4 figs., 4 tabs.

  1. Millwater Pumping System Optimization Improves Efficiency and Saves Energy at an Automotive Glass Plant

    Energy Technology Data Exchange (ETDEWEB)

    2003-03-01

    In 2001, the Visteon automotive glass plant in Nashville, Tennessee renovated its millwater pumping system. This improvement saved the plant $280,000 annually in energy and operating costs, reduced annual energy consumption by 3.2 million kilowatt-hours, reduced water consumption, improved system performance, and reduced use of water treatment chemicals.

  2. Energy Savings Lifetimes and Persistence

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Billingsley, Megan A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schwartz, Lisa C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from a national collection of costs and savings for electric efficiency programs and portfolios.

  3. Energy and cost saving results for advanced technology systems from the Cogeneration Technology Alternatives Study (CTAS)

    Science.gov (United States)

    Sagerman, G. D.; Barna, G. J.; Burns, R. K.

    1979-01-01

    An overview of the organization and methodology of the Cogeneration Technology Alternatives Study is presented. The objectives of the study were to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the future and to assess the advantages of advanced technology systems compared to those systems commercially available today. Advanced systems studied include steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics. Steam turbines, open cycle gas turbines, combined cycles, and diesel engines were also analyzed in versions typical of today's commercially available technology to provide a base against which to measure the advanced systems. Cogeneration applications in the major energy consuming manufacturing industries were considered. Results of the study in terms of plant level energy savings, annual energy cost savings and economic attractiveness are presented for the various energy conversion systems considered.

  4. Fossil energy savings potential of sugar cane bio-energy systems

    DEFF Research Database (Denmark)

    Nguyen, Thu Lan T; Hermansen, John Erik; Sagisaka, Masayuki

    2009-01-01

    and gasoline, respectively. This paper takes a closer look at the Thai sugar industry and examines two practical approaches that will enhance fossil energy savings. The first one addresses an efficient extraction of energy in the form of electricity from the excess bagasse and cane trash. The second while...... proposing to convert molasses or sugar cane to ethanol stresses the use of bagasse as well as distillery spent wash to replace coal in meeting ethanol plants' energy needs. The savings potential achieved with extracting ethanol from surplus sugar versus current practice in sugar industry in Thailand amounts...

  5. Stationary super-capacitor energy storage system to save regenerative braking energy in a metro line

    International Nuclear Information System (INIS)

    Teymourfar, Reza; Asaei, Behzad; Iman-Eini, Hossein; Nejati fard, Razieh

    2012-01-01

    Highlights: ► Super-capacitors are used to store regenerative braking energy in a metro network. ► A novel approach is proposed to model easily and accurately the metro network. ► An efficient approach is proposed to calculate the required super-capacitors. ► Maximum energy saving is around 44% at off-peak period and 42% at peak period. ► Benefit/cost analyses are performed for the suggested ESS. - Abstract: In this paper, the stationary super-capacitors are used to store a metro network regenerative braking energy. In order to estimate the required energy storage systems (ESSs), line 3 of Tehran metro network is modeled through a novel approach, in peak and off-peak conditions based on the real data obtained from Tehran metro office. A useful method is proposed to predict the maximum instantaneous regenerative energy which is delivered to each station before applying ESS and based on that the ESS configuration for each station is determined. Finally, the effectiveness of the proposed ESS is confirmed by economic evaluations and benefit/cost analyses on line 3 of Tehran metro network.

  6. Variable flow controls of closed system pumps for energy savings in maritime power systems

    DEFF Research Database (Denmark)

    Su, Chun-Lien; Liao, Chi-Hsiang; Chou, Tso-Chu

    2016-01-01

    pumps on marine vessels. The existing problem of traditional control methods for closed system pumps is analyzed and a mathematical model for variable flow controls with the appropriate control settings is derived. The performance of the proposed method is demonstrated and verified through experimental...... and field tests of a practical auxiliary boiler feed water management system on a commercial vessel. It is proved that the proposed method can maintain constant water pressure for closed system pumps and provide an efficient way to measure energy savings and maintenance benefits. The results serve......Pumps are extensively used in maritime industries as marine vessels utilize a wide range of pumps and pumping techniques to transfer and distribute all types of air and fluids. The electrical energy consumed by the various motors accounts for about 70% of a vessel’s total power consumption...

  7. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Florida Solar Energy Center (FSEC); IBACOS; National Renewable Energy Laboratory (NREL)

    2006-08-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in Cold Climates on a cost-neutral basis.

  8. Energy-Saving Analysis of Solar Heating System with PCM Storage Tank

    Directory of Open Access Journals (Sweden)

    Juan Zhao

    2018-01-01

    Full Text Available A solar heating system (SHS with a phase change material (PCM thermal storage tank is proposed with the view that traditional heat water storage tanks present several problems including large space requirements, significant heat loss and unstable system performance. An entire heating season (November–March is selected as the research period on the basis of numerical models of the SHS-PCM. In addition, taking a public building in Lhasa as the object, the heating conditions, contribution rate of solar energy, and overall energy-saving capability provided by the heating system are analyzed under different PCM storage tanks and different terminal forms. The results show that an SHS with a PCM tank provides a 34% increase in energy saving capability compared to an ordinary water tank heating system. It is suggested that the design selection parameters of the PCM storage tank should specify a daily heat storage capacity that satisfies 70~80% of the entire heating season. A floor radiant system with supply/return water temperatures of 40/35 °C provides the optimal operation and the largest energy saving capability.

  9. Potency of energy saving and emission reduction from lighting system in residential sector of Indonesia

    Science.gov (United States)

    Ambarita, H.

    2018-03-01

    The Government of Indonesia (GoI) has a strong commitment to the target of decreasing energy intensity and reducing Greenhouse gas emissions. One of the significant solutions to reach the target is increasing energy efficiency in the lighting system in the residential sector. The objective of this paper is twofold, to estimate the potency of energy saving and emission reduction from lighting in the residential sector. Literature related to the lighting system in Indonesia has been reviewed to provide sufficient data for the estimation of the energy saving and emission reduction. The results show that the in the year 2016, a total of 95.33 TWh of nationally produced electricity is used in the residential sector. This is equal to 44% of total produced electricity. The number of costumers is 64.78 million houses. The average number of lamps and average wattage of lamps used in Indonesia are 8.35 points and 13.8 W, respectively. The number of lighting and percentage of electricity used for lighting in the residential sector in Indonesia are 20.03 TWh (21.02 %) and 497 million lamps, respectively. The projection shows that in the year 2026 the total energy for lighting and number of lamps in the residential sector are 25.05 TWh and 619 million, respectively. By promoting the present technology of high efficient lamps (LED), the potency of energy saving and emission reduction in 2026 are 2.6 TWh and 2.1 million tons CO2eq, respectively.

  10. Energy-Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

    Directory of Open Access Journals (Sweden)

    Min-Suk Jo

    2017-11-01

    Full Text Available This paper aimed to evaluate the applicability of adiabatic humidification in the heating, ventilation, and air conditioning (HVAC systems of semiconductor cleanrooms. Accurate temperature and humidity control are essential in semiconductor cleanrooms and high energy consumption steam humidification is commonly used. Therefore, we propose an adiabatic humidification system employing a pressurized water atomizer to reduce the energy consumption. The annual energy consumption of three different HVAC systems were analyzed to evaluate the applicability of adiabatic humidification. The studied cases were as follows: (1 CASE 1: a make-up air unit (MAU with a steam humidifier, a dry cooling coil (DCC, and a fan filter unit (FFU; (2 CASE 2: a MAU with the pressurized water atomizer, a DCC, and a FFU; and (3 CASE 3: a MAU, a DCC, and a FFU, and the pressurized water atomizer installed in the return duct. The energy saving potential of adiabatic humidification over steam humidification has been proved, with savings of 8% and 23% in CASE 2 and CASE 3 compared to CASE 1, respectively. Furthermore, the pressurized water atomizer installed in the return duct exhibits greater energy saving effect than when installed in the MAU.

  11. Energy-saving control model of inverter for centrifugal pump systems

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2015-06-01

    Full Text Available The inverter control strategy is the key to pump energy-saving operation and should be established based on the current system configurations and system requirements, which is not the case in practice. As a result, the characteristics of pump system requirements and a combination pump with inverter were studied, and the mathematical models were established. A new model for an optimal inverter control strategy based on the current system configurations and system requirements was then established, and a method combining golden section search and genetic algorithm was formulated to solve this optimal model. This model sets up an optimal inverter control strategy to increase the efficiency of pump operation following a process line near the minimum requirements to improve operation conditions. The implementation difficulty of the control law was also reduced. Finally, the optimized model was applied to an industrial circulating pump system, and the result showed that the model can not only determine the optimal inverter control strategy but also evaluate the current operation situation of the pump configuration and determine the energy-saving potential for the current configuration, which can aid in the subsequent energy-saving reconstruction.

  12. Revolving fund for energy saving

    International Nuclear Information System (INIS)

    Prebensen, K.

    1993-01-01

    A key issue in Eastern Europe is the adjustment of prices from the former COMECON level to a level conforming with free market conditions. In the case of household heating, this issue involves the removal of government subsidies leading to sharply increasing prices, metering of individual consumption, improving the efficiency of energy production, distribution and use - where savings of 30-50% in each link are technically feasible - thereby providing a potential for a adapting consumption patterns to higher energy prices, provided that funds are available. Currently, investment in commercial heat production and distribution systems have received substantial international support - whereas investment in reduction of demand has been little exploited. The Revolving Fund for Energy Savings in Polish Households is a concept for efficient financing of small-scale projects. It aims at financing, on the level of housing cooperatives, on the basis of a simplified lending and project evaluation procedure, well suited to current Polish conditions or an organizationally and financially weak banking system and little developed technical knowledge in the field of energy saving. A general introduction to the issue is given and technical problems are elaborated. The implementation of Energy Savings in Housing seen from the banking point of view, and a current pilot scheme for financing, are described. (AB)

  13. Energy and cost savings results for advanced technology systems from the Cogeneration Technology Alternatives Study /CTAS/

    Science.gov (United States)

    Sagerman, G. D.; Barna, G. J.; Burns, R. K.

    1979-01-01

    The Cogeneration Technology Alternatives Study (CTAS), a program undertaken to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the 1985-2000 time period, is described, and preliminary results are presented. Two cogeneration options are included in the analysis: a topping application, in which fuel is input to the energy conversion system which generates electricity and waste heat from the conversion system is used to provide heat to the process, and a bottoming application, in which fuel is burned to provide high temperature process heat and waste heat from the process is used as thermal input to the energy conversion system which generates energy. Steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics are examined. Expected plant level energy savings, annual energy cost savings, and other results of the economic analysis are given, and the sensitivity of these results to the assumptions concerning fuel prices, price of purchased electricity and the potential effects of regional energy use characteristics is discussed.

  14. An energy-saving nonlinear position control strategy for electro-hydraulic servo systems.

    Science.gov (United States)

    Baghestan, Keivan; Rezaei, Seyed Mehdi; Talebi, Heidar Ali; Zareinejad, Mohammad

    2015-11-01

    The electro-hydraulic servo system (EHSS) demonstrates numerous advantages in size and performance compared to other actuation methods. Oftentimes, its utilization in industrial and machinery settings is limited by its inferior efficiency. In this paper, a nonlinear backstepping control algorithm with an energy-saving approach is proposed for position control in the EHSS. To achieve improved efficiency, two control valves including a proportional directional valve (PDV) and a proportional relief valve (PRV) are used to achieve the control objectives. To design the control algorithm, the state space model equations of the system are transformed to their normal form and the control law through the PDV is designed using a backstepping approach for position tracking. Then, another nonlinear set of laws is derived to achieve energy-saving through the PRV input. This control design method, based on the normal form representation, imposes internal dynamics on the closed-loop system. The stability of the internal dynamics is analyzed in special cases of operation. Experimental results verify that both tracking and energy-saving objectives are satisfied for the closed-loop system. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Burlington, MA (United States); Shandross, Richard [Navigant Consulting, Burlington, MA (United States); Young, Jim [Navigant Consulting, Burlington, MA (United States); Petritchenko, Oxana [Navigant Consulting, Burlington, MA (United States); Ringo, Decker [Navigant Consulting, Burlington, MA (United States); McClive, Sam [Navigant Consulting, Burlington, MA (United States)

    2017-12-01

    The Building Technologies Office (BTO) commissioned this characterization and technology assessment of heating, ventilation, and air-conditioning (HVAC) systems for commercial buildings. The main objectives of this study: Identify a wide range of technology options in varying stages of development that could reduce commercial HVAC energy consumption; Characterize these technology options based on their technical energy-savings potential, development status, non-energy benefits, and other factors affecting end-user acceptance and the ability to compete with conventional HVAC technologies; Make specific recommendations to DOE and other stakeholders on potential research, development, and demonstration (RD&D) activities that would support further development of the most promising technology options.

  16. Energy savings from temperature setpoints and deadband: Quantifying the influence of building and system properties on savings

    International Nuclear Information System (INIS)

    Ghahramani, Ali; Zhang, Kenan; Dutta, Kanu; Yang, Zheng; Becerik-Gerber, Burcin

    2016-01-01

    Highlights: • We provide a systematic approach to quantify the impact of factors on energy usage. • We study setpoints, deadbands, building size, construction, occupancy, and climate. • We derive the HVAC optimal control parameters with respect to dynamic factors. • We present quantification of optimal setpoints and deadbands energy usages. • Daily optimal setpoints based on outside temperature improves energy efficiency. - Abstract: This paper provides a systematic approach for quantifying the influence of building size, construction category, climate, occupancy schedule, setpoint, and deadband on HVAC energy consumption in office buildings. Simulating the DOE reference office buildings of three sizes and three construction categories in all United States climate zones, using the EnergyPlus, we conducted several N-way ANOVA analyses to study the interrelationships between setpoints, deadbands and several building related and environment related factors. In summary, daily optimal deadband selection of 0, 1, 2, 4, 5, and 6 K would result in an average energy savings of −70.0%, −34.9%, −13.7%, 9.6%, 16.4%, and 21.2%, respectively, compared to baseline deadline of 3 K. Selecting the daily optimal setpoint in the range of 22.5 ± 1 °C, 22.5 ± 2 °C, and 22.5 ± 3 °C would result in an average savings of 7.5%, 12.7%, and 16.4%, respectively, compared to the baseline setpoint of 22.5 °C. Additionally, we found that when the outdoor temperature is within −20 to 30 °C, the optimal setpoint depends on the building size. We also observed a range of outdoor temperatures (e.g., 9–14 °C for small buildings and 8–11 °C for medium buildings) where the setpoint selection would only slightly influence the energy consumption. However, the choice of setpoints becomes very influential (up to 30% of energy savings) where the outdoor temperatures are slightly outside the mentioned ranges on either direction. The potential savings from selecting daily optimal

  17. An Intelligent Energy Saving System for Controlling the Lighting and Ventilation of an Area

    OpenAIRE

    Kadiri Kamoru. O; Omotosho O. J

    2014-01-01

    Intelligent Energy Saving System is a control system used to control a particular environment in other to optimize the energy. It can be used to control the lighting or air conditioning of an area. An example is the library which can be well illuminated with many lamps. When people are not present at a reading place, the lighting can be made OFF and when they are present, the lighting is made ON by using a sensor to sense the environment condition example temperature, obstacle etc. All these ...

  18. Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts

    Energy Technology Data Exchange (ETDEWEB)

    Doulos, L.; Topalis, F. [Laboratory of Photometry, National Technical University of Athens, Iroon Politexniou 9, 157 80 Zografou (Greece); Tsangrassoulis, A. [Department of Architecture, University of Thessaly, Pedion Areos, 383 34 Volos (Greece)

    2008-07-01

    The application of lighting control technologies with photosensors has led to an increase in public interest. Although these technologies have been promoted during the last years their successful use in buildings has been accomplished in a small percentage of new projects. One reason is the difficulty in quantifying the energy savings and thus the subsequent payback period. Daylight responsive dimming systems consist of three basic components: photosensor, controller, and dimming unit. Electronic dimming ballast (EDB) is one substantial component of these lighting control systems which can adjust the light output due to the transferred signal from the photosensor and lighting controller. The aim of this study is to quantify energy savings among different EDBs. Eighteen commercial EDBs were selected and various sets of electrical and illuminance measurements were taken for different dimming levels, in order to develop polynomial functions between light output and consumed power. Using the measured data, a set of simulations were performed for a photosensor with an ideal cosine spatial sensitivity distribution installed in a typical office room using two control algorithms, closed loop and integral reset, trying to quantify the relative differences in energy savings. (author)

  19. Tourists' attitudes for selecting accommodation with investments in renewable energy and energy saving systems

    International Nuclear Information System (INIS)

    Tsagarakis, Konstantinos P.; Bounialetou, Fanouria; Gillas, Konstantinos; Profylienou, Maroulitsa; Pollaki, Antrianna; Zografakis, Nikolaos

    2011-01-01

    This paper aims at providing useful insights into tourists' preferences for choosing to stay in hotels equipped with Energy Saving Installations (ESI) and Renewable Energy Sources (RES). Factors related to these decisions were studied through 2308 face to face interviews taken at the departure terminals of the two international airports of Crete, Greece. Results show that 86% of the respondents would prefer to stay in hotels equipped with ESI, and 87% in hotels with RES, rather than staying in hotels of identical quality which do not have either ESI or RES. Furthermore, the percentages of respondents who would be willing to pay fee surcharges for a hotel equipped with ESI or RES are 75 and 77%, respectively, as compared to hotels of identical quality which do not have either ESI or RES. Tourists from countries with high energy awareness, prove to be more willing to choose to stay at and pay for hotels with ESI and RES. (author)

  20. Design and Development of an Intelligent Energy Controller for Home Energy Saving in Heating/Cooling System

    Science.gov (United States)

    Abaalkhail, Rana

    Energy is consumed every day at home as we perform simple tasks, such as watching television, washing dishes and heating/cooling home spaces during season of extreme weather conditions, using appliances, or turning on lights. Most often, the energy resources used in residential systems are obtained from natural gas, coal and oil. Moreover, climate change has increased awareness of a need for expendable, energy resources. As a result, carbon dioxide emissions are increasing and creating a negative effect on our environment and on our health. In fact, growing energy demands and limited natural resource might have negative impacts on our future. Therefore, saving energy is becoming an important issue in our society and it is receiving more attention from the research community. This thesis introduces a intelligent energy controller algorithm based on software agent approach that reduce the energy consumption at home for both heating and cooling spaces by considering the user's occupancy, outdoor temperature and user's preferences as input to the system. Thus the proposed approach takes into consideration the occupant's preferred temperature, the occupied and unoccupied spaces, as well as the time spent in each area of the home. A Java based simulator has been implemented to simulate the algorithm for saving energy in heating and cooling systems. The results from the simulator are compared to the results of using HOT2000, which is Canada's leading residential energy analysis and rating software developed by CanmetENERGY's Housing, Buildings, Communities and Simulation (HBCS) group. We have calculated how much energy a home modelled will use under emulated conditions. The results showed that the implementation of the proposed energy controller algorithm can save up to 50% in energy consumption in homes dedicated to heating and cooling systems compared to the results obtained by using HOT2000.

  1. The environmental performance of solar energy systems and related energy saving installations

    NARCIS (Netherlands)

    Veenstra, A.; Oversloot, H.P.; Spoorenberg, H.H.R.

    2001-01-01

    Renewable energy systems are contributing to environmental protection if looked upon from the energy point of view. But also aspects like resource depletion and waste production need attention. A desired large-scale introduction of renewable energy systems will require large quantities of resources

  2. Economic benefits of an economizer system: Energy savings and reduced sick leave

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Seppanen, Olli; Faulkner, David; Huang, Joe

    2004-02-01

    This study estimated the health, energy, and economic benefits of an economizer ventilation control system that increases outside air supply during mild weather to save energy. A model of the influence of ventilation rate on airborne transmission of respiratory illnesses was used to extend the limited data relating ventilation rate with illness and sick leave. An energy simulation model calculated ventilation rates and energy use versus time for an office building in Washington, D.C. with fixed minimum outdoor air supply rates, with and without an economizer. Sick leave rates were estimated with the disease transmission model. In the modeled 72-person office building, our analyses indicate that the economizer reduces energy costs by approximately $2000 and, in addition, reduces sick leave. The annual financial benefit of the decrease in sick leave is estimated to be between $6,000 and $16,000. This modeling suggests that economizers are much more cost effective than currently recognized.

  3. Thermal analysis of a hybrid solar energy saving system inside a greenhouse

    International Nuclear Information System (INIS)

    Ntinas, G.K.; Fragos, V.P.; Nikita-Martzopoulou, Ch.

    2014-01-01

    Highlights: • A hybrid solar system consisted of water filled polyethylene sleeves was examined. • The thermal behaviour of the system was studied based on the sleeves energy balance. • Water temperature and heat exchanges of the sleeves were dynamically estimated. • Experimental data used to validate the predictions of the mathematical model. • The use of the system led to an energy saving of 23% inside a heated greenhouse. - Abstract: The intensive greenhouse energy requirements are a major operational and economical problem for producers around the world. Energy conservation techniques and innovative applications of solar energy for heating are being employed in greenhouse operation to reduce heating costs during cold periods. The present study investigated the development of a mathematical model to predict the thermal efficiency of a novel hybrid solar energy saving system inside a heated greenhouse. The solar system consisted of a transparent water-filled polyethylene sleeve and two perforated air-filled polyethylene tubes on the top peripheral sides of it. Above the sleeve and between the two tubes, rockwool substrates were placed for hydroponic cultivation of tomato crop. In order to validate this model, experiments were carried out in two identical parts of a polyethylene arched-type greenhouse to obtain data during winter. By comparing the measured and the predicted values, a correlation of 95% was found, indicating that the model can simulate the water temperature inside the hybrid solar sleeves. Moreover, the additional energy provided by the hybrid solar system reached approximately 23% during the examined period, depending on solar radiation levels

  4. Feasibility study on renewable energy systems and selected insulation applications : smart solutions for energy saving

    OpenAIRE

    Cuadra Fonseca, Sergio

    2013-01-01

    Energy represents a big challenge for future generations; not only mineral and fossil energy sources are being exhausted, but also GHG emissions pollute the environment and disrupt life natural cycles bringing serious irreversible impacts on earth. Renewable energy sources, on the other hand, are unexhausted and free of pollution; solar power systems play an important role in the generation of clean energy, being one of the most cost-effective solutions. Besides, solar power systems have ...

  5. Energy-Saving Control of a Novel Hydraulic Drive System for Field Walking Robot

    Science.gov (United States)

    Fang, Delei; Shang, Jianzhong; Xue, Yong; Yang, Junhong; Wang, Zhuo

    2018-01-01

    To improve the efficiency of the hydraulic drive system in field walking robot, this paper proposed a novel hydraulic system based on two-stage pressure source. Based on the analysis of low efficiency of robot single-stage hydraulic system, the paper firstly introduces the concept and design of two-stage pressure source drive system. Then, the new hydraulic system energy-saving control is planned according to the characteristics of walking robot. The feasibility of the new hydraulic system is proved by the simulation of the walking robot squatting. Finally, the efficiencies of two types hydraulic system are calculated, indicating that the novel hydraulic system can increase the efficiency by 41.5%, which can contribute to enhance knowledge about hydraulic drive system for field walking robot.

  6. Stepless control system for reciprocating compressors: energy savings + process control improvement

    Energy Technology Data Exchange (ETDEWEB)

    Grande, Alvaro; Wenisch, Markus [Hoerbiger Ventilwerke GmbH and Co KG, Wien (Austria); Jacobs, Denis [HOERBIGER do Brasil Industria de Equipamentos, Cajamar, SP (Brazil)

    2012-07-01

    In the past, the capacity of reciprocating compressors was typically controlled by on/off unloaders (step-control) and recycle valves. But due to the fact that the power ratings of new reciprocating compressors for the oil and gas industry increase significantly, advanced control systems are required to reduce power costs and save energy. On top of that, multi-stage compressors are frequently integrated into complex process plants that demand precise control and operational flexibility. There are several solutions for this equation, but maybe the most successful is the use of the reverse flow principle applied to an electronically controlled and hydraulically actuated suction valve unloaders system. (author)

  7. Energy Saving and GHG Emission Reduction in a Micro-CCHP System by Use of Solar Energy

    OpenAIRE

    Ion, I; Ciocea, G; Popescu, F

    2012-01-01

    In this work, the reduction of greenhouse gas emission, and the energy saving by integrating solar collectors and photovoltaic panels in a Stirling engine based microcombined cooling, heating and power (mCCHP) system are studied. The mCCHP system consists of a natural gas Stirling CHP and an adsorber chiller. When the thermal outputs of the Stirling CHP and solar collectors are not sufficient to cover the heat demand for domestic hot water (DHW), heating/cooling, an au...

  8. Modeling Urban Energy Savings Scenarios Using Earth System Microclimate and Urban Morphology

    Science.gov (United States)

    Allen, M. R.; Rose, A.; New, J. R.; Yuan, J.; Omitaomu, O.; Sylvester, L.; Branstetter, M. L.; Carvalhaes, T. M.; Seals, M.; Berres, A.

    2017-12-01

    We analyze and quantify the relationships among climatic conditions, urban morphology, population, land cover, and energy use so that these relationships can be used to inform energy-efficient urban development and planning. We integrate different approaches across three research areas: earth system modeling; impacts, adaptation and vulnerability; and urban planning in order to address three major gaps in the existing capability in these areas: i) neighborhood resolution modeling and simulation of urban micrometeorological processes and their effect on and from regional climate; ii) projections for future energy use under urbanization and climate change scenarios identifying best strategies for urban morphological development and energy savings; iii) analysis and visualization tools to help planners optimally use these projections.

  9. Energy savings in CSFR - building sector

    International Nuclear Information System (INIS)

    Jacobsen, F.R.

    1993-01-01

    The Czechoslovak/Danish project on energy savings in buildings proves that it is possible to save up to 30% of the energy in buildings. 10% can be saved at an investment of 27 bill KCS. The total investment that is needed to save 30% is 140 bill KCS. Further energy savings can be obtained through more energy efficient supply systems. Information dissemination is important for the energy saving programme as are economic incentives. Investments in energy savings should be profitable for the investor, but this is not the case in the Czech and Slovak republics today. Changes are needed. Energy prices are still to low, compared to investment costs. Financial possibilities are not satisfactory for private investors. Price systems are not favourable to investment in energy savings. Training is needed for boiler men and energy consultants. Legislation is essential for the support of the full range of activities in the energy sector. Research and Development activities must back up the development of the sector. Pilot projects can illuminate the savings potential. The production of technical equipment for control and metering and production of insulation materials must be promoted. (AB)

  10. Dynamic target high pressure control of a VRF system for heating energy savings

    International Nuclear Information System (INIS)

    Yun, Geun Young; Lee, Je Hyeon; Kim, Inhan

    2017-01-01

    Highlights: • We developed the dynamic target high pressure control of a VRF system. • We created the VRF control model using the EnergyPlus runtime language. • Multicalorimeter experimental results indicate that the energy efficiency improved by 21%. • EnergyPlus simulations demonstrate that the annual heating energy consumption was lowered by 22%. - Abstract: Variable refrigerant flow (VRF) systems are widely used because of their ability to provide individualized comfort control with energy-saving potential. This study develops load responsive high pressure control of a VRF system with the aim of reducing the heating energy consumption of a VRF system under part load conditions. The developed control consists of two parts: one part that determines the level of heating load, and the other that assigns a target high pressure based on the level of heating load. In this way, the compressor speed can be accurately matched to heating load, which improves the energy performance of the VRF system. A series of multicalorimeter experiments revealed that the heating capacity of the VRF system varied by 45% by modulating the target high pressure and that its efficiency was enhanced by 21% by changing the high pressure from 30 kgf/cm 2 to 25 kgf/cm 2 . To evaluate the annual heating energy performance of the VRF system with the developed control, a custom computer code was developed to implement the developed control using a programming language called EnergyPlus Runtime Language. Simulation outcomes showed that the annual heating energy consumption of a medium-size office building was reduced by 22% when the developed control was applied.

  11. Compressed Air System Optimization Saves Energy and Improves Production at a Textile Manufacturing Mill (Peerless Division, Thomastown Mills, Inc.)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-06-01

    This case study is one in a series on industrial firms who are implementing energy efficient technologies and system improvements into their manufacturing processes. This case study documents the activities, savings, and lessons learned on the textile manufacturing mill project.

  12. Energy-Saving Tunnel Illumination System Based on LED's Intelligent Control

    International Nuclear Information System (INIS)

    Guo Shanshan; Wu Lan; Gu Hanting; Jiang Shuixiu

    2011-01-01

    At present there is a lot of electric energy wastage in tunnel illumination, whose design is based on the maximum brightness outside and the maximum vehicle speed all year round. LED's energy consumption is low, and the control of its brightness is simple and effective. It can be quickly adjusted between 0-100% of its maximum brightness, and will not affect the service life. Therefore, using LED as tunnel's illumination source, we can achieve a good energy saving effect. According to real-time data acquisition of vehicle speed, traffic flow and brightness outside the tunnel, the auto real-time control of tunnel illumination can be achieved. And the system regulated the LED luminance by means of combination of LED power module and intelligent control module. The tunnel information was detected by inspection equipments, which included luminometer, vehicle detector, and received by RTU(Remote Terminal Unit), then synchronously transmitted to PC. After data processing, RTU emitted the dimming signal to the LED driver to adjust the brightness of LED. Despite the relatively high cost of high-power LED lights, the enormous energy-saving effect and the well-behaved controllability is beyond compare to other lighting devices.

  13. Hot times in Whistler : energy saving hybrid systems in area hotels

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2008-01-15

    The resort of Whistler in British Columbia is to host the 2010 Winter Olympics, and the town of Whistler has committed to reducing energy consumption and emissions output in the community's 9500 dwelling units. Commercial hotels and mountain operations in the region are facing higher costs associated with tanked propane supply systems and higher infrastructure costs for some of the proposed alternatives. This article described a hybrid heating system designed by Sempa Power Systems. The systems have now been installed in conference centres and on all large mountain lodge complexes in the region. The hybrid heating system is a patent-pending system that automatically load-balances fossil fuel sources with electricity consumption to reduce energy costs, decrease GHG emissions, and increase efficiencies. Clients at the complexes are monitored online in real time and analyses of empirical data are compared with actual consumption to historical baseline averages. It was concluded that complexes in which the systems have been installed are averaging 28 per cent energy savings, a 39 per cent reduction in greenhouse gases (GHGs), and a 13 per cent reduction in energy consumption. 2 figs.

  14. Saving and gaining energy

    International Nuclear Information System (INIS)

    Lauritzen, T.

    2008-01-01

    In this interview with Dirk U. Hindrichs from the Schueco International KG company, differences between ecological and economical points of view in general are discussed, as is the world's energy consumption and the visions held by the Schueco company in this respect. The importance of building facades, windows and photovoltaics for his business is discussed, as are solar thermal systems for the production of heat and cold. Further, energy-efficiency and examples of buildings realised internationally are discussed and co-operation with important players in the climate protection area is noted. Hindrichs' opinion, that pro-active actions must be taken by entrepreneurs, is noted.

  15. European Union Energy Saving Policy

    Directory of Open Access Journals (Sweden)

    Nikolay Y. Kaveshnikov

    2014-01-01

    Full Text Available This article analyses methods of energy efficiency stimulation in the European Union. The author investigates basic areas of the EU activity; in particular, the author estimates results of implementation of the Energy Star program, new provisions of labeling of energy-using products, measures to increase energy efficiency in buildings. The paper also analyzes the provisions of the Directive 2012/27 that is the first EU document, providing for a comprehensive approach to energy saving at all stages: production, transformation and consumption. Today EU policy includes: 7 a general political and regulatory framework laid down by the European action plan on energy efficiency and Directive 2012/27; 2 national action plans on energy efficiency, which should be in line with indicative targets set at the EU level; 3 special EU documents in key areas of energy efficiency (buildings, energy-consuming equipment etc.; 4 accompanying instruments, such as target funding, information dissemination, support of specialized networks. The paper gives a comprehensive analysis of the key methods of implementation of EU policy in the area of energy saving. The author concludes that EU operates within the framework of the open method of coordination. The system of mandatory/voluntary technical standards has allowed to achieve significant success, but indicative planning and monitoring of national actions are not completely effective. In the long term EU policy in the area of energy efficiency is restrained by member states unwillingness to delegate to the European Union a more detailed powers in this field and to give the EU bodies facilities to execute more strict control. In the short term - in conditions of economic crisis, the EU countries are not ready to invest significant budget funds in projects with long payback period.

  16. Combinatorial Optimization for Energy Saving in Nickel Industry Non-Newtonian Fluid Pumping System

    International Nuclear Information System (INIS)

    Hernández Ramírez, Gabriel; Legra Lobaina, Aristides; Columbié Navarro, Angel; Marcos Aníbal León Segovia

    2017-01-01

    In the present work a study of the influence of the rheological parameters of the lateritic hydromixtures with the energetic ones of the pumping systems that guarantee the productivity of nickel company 'Commander Pedro Sotto Alba' is carried out. From an experimental study and through an estimator, the rheological parameters are modeled as a function of the factors: temperature, solids content, chemical and granulometric composition. From an appropriate discretization of the model of the lateritic hydrometer pumping system and the application of a Discrete Combination Optimization Double Sequencing procedure, the operating parameters of this system were obtained, in order to guarantee a flow rate of 1600 m3 / h and one Adequate solids concentration. It is concluded that the use of a mathematical model that relates the rheological parameters of the lateritic pulp and the energy parameters of the pumping system, guarantee the metallurgical and energy efficiency in the acid leaching process with an average increase in production between 1000-1500 T Ni + Co / y and an energy saving of 30 MWh /year. (author)

  17. Energy-saving implications from supply chain improvement: An exploratory study on China's consumer goods retail system

    International Nuclear Information System (INIS)

    Wang, Xi; Cai, Hua; Florig, H. Keith

    2016-01-01

    Despite significant public attentions to green supply chain management, few studies have explicitly addressed the energy implications of consumer-goods supply surplus, especially in developing countries like China. This study explored the energy-saving potential from improving supply chain efficiencies and reducing excess inventory in China's retail system from a life-cycle perspective. Through embodied energy analysis, we found that energy invested pre-manufacture contributed 80–95% of the total energy embodied in consumer products. Although embodied energy intensities had declined by 60–90% since the mid-1990s, the lessened marginal improvements implied that "low hanging fruits" have largely been captured, and the search for new opportunities for energy-saving is in demand. Positive correlations between total economic inputs and embodied energy in consumer goods indicated possible synergy effect between cost-reduction and energy-saving in supply system management. And structural path analysis identified sector-specific energy management priorities for each retail-related sector. This study suggested that improving supply chain efficiencies provides a promising supplement to China's current industrial energy-efficient projects which target reducing direct energy use per se as an intra-firm cost-saving measure. From the life-cycle perspective, the definition of "green sector" might have to be reconsidered in China towards a more energy-efficient economy and society.

  18. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document

  19. Saving energy by using underfloor-air-distribution (UFAD) system in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Alajmi, Ali [Department of Mechanical Engineering, College of Technological Studies, Public Authority of Applied Education and Training, P.O. Box 3831, Mishref 40189 (Kuwait); El-Amer, Wid [Mechanical Department Head in Option One International Office, P.O. Box 29667, Safat 13157 (Kuwait)

    2010-08-15

    The number of attempts by researchers to reduce building energy consumption has increased, ever since global warming became a serious issue. In this trend, a relatively new approach of air distribution, underfloor-air-distribution system (UFAD), has been widely used in new commercial buildings. This technique is simply accomplished by supplying air through a raised floor using different types of distribution configurations and outlets. In UFAD, the air is directly supplied to the occupants' area (occupied zone) causing occupants plumes and zone heat load stratify to the upper layer of the zone (unoccupied zone), which are later extracted from return points at high level. This flow pattern gives UFAD the advantage of using less energy than a conventional air-distribution system, ceiling-based air distribution (CBAD) due to lower pressure drop and lower air flow rate. This paper investigates the effectiveness of UFAD systems in commercial buildings for various types of application and at different air supply temperatures in a hot climate (The State of Kuwait). The findings show that UFAD has a significant saving of energy compared to CBAD ({proportional_to}30%); in particular with high ceiling building types, as well as providing satisfactory comfort conditions for the occupants. Ultimately, more investigations should be done on conventional building heights (offices) to optimize the utilization of thermal stratification at design and operation stages. (author)

  20. Saving energy by using underfloor-air-distribution (UFAD) system in commercial buildings

    International Nuclear Information System (INIS)

    Alajmi, Ali; El-Amer, Wid

    2010-01-01

    The number of attempts by researchers to reduce building energy consumption has increased, ever since global warming became a serious issue. In this trend, a relatively new approach of air distribution, underfloor-air-distribution system (UFAD), has been widely used in new commercial buildings. This technique is simply accomplished by supplying air through a raised floor using different types of distribution configurations and outlets. In UFAD, the air is directly supplied to the occupants' area (occupied zone) causing occupants plumes and zone heat load stratify to the upper layer of the zone (unoccupied zone), which are later extracted from return points at high level. This flow pattern gives UFAD the advantage of using less energy than a conventional air-distribution system, ceiling-based air distribution (CBAD) due to lower pressure drop and lower air flow rate. This paper investigates the effectiveness of UFAD systems in commercial buildings for various types of application and at different air supply temperatures in a hot climate (The State of Kuwait). The findings show that UFAD has a significant saving of energy compared to CBAD (∼30%); in particular with high ceiling building types, as well as providing satisfactory comfort conditions for the occupants. Ultimately, more investigations should be done on conventional building heights (offices) to optimize the utilization of thermal stratification at design and operation stages.

  1. The High Cost of Saving Energy Dollars.

    Science.gov (United States)

    Rose, Patricia

    1985-01-01

    In alternative financing a private company provides the capital and expertise for improving school energy efficiency. Savings are split between the school system and the company. Options for municipal leasing, cost sharing, and shared savings are explained along with financial, procedural, and legal considerations. (MLF)

  2. Potential of energy saving with photovoltaic systems; Potencialidad de ahorro de energia con sistemas fotovoltaicos

    Energy Technology Data Exchange (ETDEWEB)

    Guzman S, Eusebio; Bratu S, Neagu [Universidad Autonoma Metropolitana, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents an approach on the application of photovoltaic systems in energy saving. The problem of the electric energy demand in the coming years is analyzed and its consequences on the environment and on the energy reserves of conventional sources. A model of the electric circuit equivalent to a photovoltaic cell illustrates the behavior of the photovoltaic cell in function of the climatological conditions. The former in order to show some of the limiting factors in this type of generator. Also, the evolution of the applications of the photovoltaic systems and its forecasting in the installed capacity in the next 20 years, is described. [Espanol] En este trabajo se presenta un enfoque de la aplicacion de los sistemas fotovoltaicos en el ahorro de energia. Se plantea el problema del crecimiento de la demanda energetica en los proximos anos y sus consecuencias sobre el medio ambiente y las reservas de energia por fuentes convencionales. Un modelo del circuito electrico equivalente de una celda fotovoltaica ilustra el comportamiento del generador fotovoltaico en funcion de las condiciones climatologicas. Lo anterior con el fin de mostrar algunas limitantes de este tipo de generador. Tambien se describe la evolucion de las aplicaciones de los sistemas fotovoltaicos y el pronostico de la potencia instalada en los proximos 20 anos.

  3. Geothermal heating saves energy

    International Nuclear Information System (INIS)

    Romsaas, Tor

    2003-01-01

    The article reviews briefly a pioneer project for a construction area of 200000 m''2 with residences, business complexes, a hotel and conference centre and a commercial college in Oslo. The energy conservation potential is estimated to be about 60-70 % compared to direct heating with oil, gas or electricity as sources. There will also be substantial reduction in environmentally damaging emissions. The proposed energy central combines geothermal energy sources with heat pump technology, utilises water as energy carrier and uses terrestrial wells for energy storage. A cost approximation is presented

  4. ENERGY EFFICIENCY, ENERGY SAVING POTENTIAL AND ENVIRONMENTAL IMPACT RESEARCH OF LPG CARRIER REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    V. О. Bedrosov

    2016-12-01

    Full Text Available Nowadays energy efficiency improvement and global warming are issues of current interest because of the natural resources depletion and extreme climate change. Thus, the problem of formation of strict regulations regarding emissions into the air arises. This paper presents the study of cascade refrigeration system for re-condensing of associated petroleum gas during sea transportation for LPG carrier. The structural optimization has been performed. LPG gas carriers with 266 000 m3 ethane capacity require 15 MW cascade refrigeration system for re-condensing if the temperature in the coastal LPG storage is -70°C, and the temperature for transported Ethan is maintained at  -75°C. For current storage conditions the required system cooling capacity is only 1,078 MW intended for the heat gain rejection from the environment during Ethane transportation. The replacement of ozone-depleting refrigerant R22 to alternative agents: R407C, R404A, R402A, R717, R290, R1270 was estimated. The results of analysis have shown that the proposed improvements can be used to optimize the LPG carrier cascade refrigeration system

  5. Energy conservation. Federal shared energy savings contracting

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Milans, Flora H.; Kirk, Roy J.; Welker, Robert A.; Sparling, William J.; Butler, Sharon E.; Irwin, Susan W.

    1989-04-01

    A number of impediments have discouraged federal agencies from using shared energy savings contracts. As of November 30, 1988, only two federal agencies - the U.S. Postal Service (USPS) and the Department of the Army -had awarded such contracts even though they can yield significant energy and cost savings. The three major impediments we identified were uncertainty about the applicability of a particular procurement policy and practice, lack of management incentives, and difficulty in measuring energy and cost savings. To address the first impediment, the Department of Energy (DOE) developed a manual on shared energy savings contracting. The second impediment was addressed when the 100th Congress authorized incentives for federal agencies to enter into shared savings contracts. DOE addressed the third impediment by developing a methodology for calculating energy consumption and cost savings. However, because of differing methodological preferences, this issue will need to be addressed on a contract-by-contract basis. Some state governments and private sector firms are using performance contracts to reduce energy costs in their buildings and facilities. We were able to identify six states that were using performance contracts. Five have established programs, and all six states have projects under contract. The seven energy service companies we contacted indicated interest in federal shared energy savings contracting

  6. Designing Rainwater Harvesting Systems Cost-Effectively in a Urban Water-Energy Saving Scheme by Using a GIS-Simulation Based Design System

    Directory of Open Access Journals (Sweden)

    Yie-Ru Chiu

    2015-11-01

    Full Text Available Current centralized urban water supply depends largely on energy consumption, creating critical water-energy challenge especially for many rapid growing Asian cities. In this context, harvesting rooftop rainwater for non-potable use has enormous potential to ease the worsening water-energy issue. For this, we propose a geographic information system (GIS-simulation-based design system (GSBDS to explore how rainwater harvesting systems (RWHSs can be systematically and cost-effectively designed as an innovative water-energy conservation scheme on a city scale. This GSBDS integrated a rainfall data base, water balance model, spatial technologies, energy-saving investigation, and economic feasibility analysis based on a case study of eight communities in the Taipei metropolitan area, Taiwan. Addressing both the temporal and spatial variations in rainfall, the GSBDS enhanced the broad application of RWHS evaluations. The results indicate that the scheme is feasible based on the optimal design when both water and energy-savings are evaluated. RWHSs were observed to be cost-effective and facilitated 21.6% domestic water-use savings, and 138.6 (kWh/year-family energy-savings. Furthermore, the cost of per unit-energy-saving is lower than that from solar PV systems in 85% of the RWHS settings. Hence, RWHSs not only enable water-savings, but are also an alternative renewable energy-saving approach that can address the water-energy dilemma caused by rapid urbanization.

  7. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Marine Climates; January 2006 - December 2006

    Energy Technology Data Exchange (ETDEWEB)

    Building America Industrialized Housing Partnership (BAIHP); Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Davis Energy Group (DEG); IBACOS; National Association of Home Builders Research Center (NAHBRC); National Renewable Energy Laboratory (NREL)

    2006-12-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Marine Climate Region on a cost neutral basis.

  8. Energy savings in Polish buildings

    Energy Technology Data Exchange (ETDEWEB)

    Markel, L.C.; Gula, A.; Reeves, G.

    1995-12-31

    A demonstration of low-cost insulation and weatherization techniques was a part of phase 1 of the Krakow Clean Fossil Fuels and Energy Efficient Project. The objectives were to identify a cost-effective set of measures to reduce energy used for space heating, determine how much energy could be saved, and foster widespread implementation of those measures. The demonstration project focused on 4 11-story buildings in a Krakow housing cooperative. Energy savings of over 20% were obtained. Most important, the procedures and materials implemented in the demonstration project have been adapted to Polish conditions and applied to other housing cooperatives, schools, and hospitals. Additional projects are being planned, in Krakow and other cities, under the direction of FEWE-Krakow, the Polish Energie Cities Network, and Biuro Rozwoju Krakowa.

  9. Energy saving potential of presence detection for lighting systems in utility buildings. Final report; Besparingspotentie aanwezigheidsdetectie voor verlichting in utiliteitsgebouwen

    Energy Technology Data Exchange (ETDEWEB)

    Van den Ham, E.R.; Nobel, K.C.J.

    2002-01-22

    A method to determine the energy saving potential of the title system is presented. [Dutch] Dit rapport geeft een methode voor het bepalen van de besparingpotentie van aanwezigheidsdetectie (AWD) op verlichtingsenergie in een gebouw of deel van een gebouw. Verder is een eenvoudige methode afgeleid om de besparing met AWD in te schatten.

  10. Saving Green on Energy Costs

    Science.gov (United States)

    Tacke, Diane L.

    2006-01-01

    In recent years, colleges and universities have begun efforts to reduce their energy costs, an initiative that can not only save an institution money, but also strengthen relationships across campus. Board leadership has been central to this endeavor in setting goals, prioritizing projects, and financing those projects. Using her experiences with…

  11. Experimental study on cooling performance and energy saving of gas engine-driven heat pump system with evaporative condenser

    International Nuclear Information System (INIS)

    Liu, Huanwei; Zhou, Qiushu; Zhao, Haibo

    2016-01-01

    Highlights: • GEHP air conditioning system with evaporative condenser was proposed. • Cooling performances under different conditions were investigated. • PER increased with increasing of evaporative condenser air velocity. • The maximum value of PER was 1.55. • The economical amount of GEHP with evaporative condenser was 28.1%. - Abstract: The gas engine-driven heat pump (GEHP) is widely utilized to the process of cooling, heating or food drying. Aiming at improving the coefficient of performance (COP), primary energy ratio (PER) and energy saving of GEHP, a GEHP system with evaporative condenser was developed and the cooling performances were experimented over a wide range of ambient air temperature (30–36 °C), evaporative condenser air velocity (2.2–3.9 m/s) and gas engine speeds (1200–2200 rpm). Experimental results showed that the cooling capacity and PER of the GEHP system with evaporative condenser increased as the increasing of evaporative condenser air velocity and decreasing of ambient air temperature. The increasing and decreasing extents of cooling capacity and PER were 12.1%, 4.8% and 8.2%, 9.0%, respectively. However, the gas engine energy consumption and gas engine waste heat decreased with the increasing of evaporative air velocity and decreasing of ambient air temperature. Meanwhile, the cooling capacity, gas engine energy consumption, gas engine waste heat increased with increasing of gas engine speed, and the increase amplitude was 75.64%, 153.2% and 153.3%, respectively. The maximum value of PER of GEHP system with evaporative condenser was 1.55, and the waste heat recovered from gas engine was more than 55% of gas engine energy consumption. The energy saving and emission saving of the GEHP with evaporative condenser were also analyzed, the PER savings of GEHP system with evaporative condenser compared to conventional air-cooled condenser were 28.1%. Furthermore, compared to the GEHP with air-cooled condenser, the primary energy

  12. SAVE ENERGY IN TEXTILE SMES

    Directory of Open Access Journals (Sweden)

    SCALIA Mauro

    2016-05-01

    Full Text Available Efficiency and competitiveness in textile and clothing manufacturing sector must take into account the current and future energy challenges. Energy efficiency is a subject of critical importance for the Textile & Clothing industry, for other sectors and for the society in general. EURATEX has initiated Energy Made-to-Measure, an information campaign running until 2016 to empower over 300 textile & clothing companies, notably SMEs, to become more energy efficient. SET( Save Energy in Textile SMEs a collaborative project co-funded within the European Programme Intelligent Energy Europe II helps companies to understand their energy consumption and allows them to compare the sector benchmarks in different production processes. SET has developed the SET tool, Energy Saving and Efficiency Tool, a free of charge tool customized for textile manufacturers. The SET tool is made up of 4 elements: a stand-alone software (SET Tool for self-assessment based on an Excel application; an on-line part (SET tool Web for advanced benchmarking and comparison of the performances across years; a guiding document for the companies and overview of financial incentives and legal obligations regarding energy efficiency. Designed specifically for small and medium enterprises (SMEs, the SET tool enables the evaluation of energy consumption and recommends measures to reduce the consumption. Prior to modifying the company’s production processes and making investments to increase energy efficiency, textile SMEs need to get different type of information, including legal context, economic and technical peculiarities.

  13. Simulation of energy saving potential of a centralized HVAC system in an academic building using adaptive cooling technique

    International Nuclear Information System (INIS)

    Bhaskoro, Petrus Tri; Gilani, Syed Ihtsham Ul Haq; Aris, Mohd Shiraz

    2013-01-01

    Highlights: • We have simulated and validated the cooling loads of a multi-zone academic building, in a tropical region. • We have analyzed the effect of occupancy patterns on the cooling loads. • Adaptive cooling technique has been utilized to minimize the energy usage of HVAC system. • The results are promising and show a reduction of energy saving in the range of 20–30%. - Abstract: Application of adaptive comfort temperature as room temperature set points potentially reduce energy usage of the HVAC system during a cooling and heating period. The savings are mainly due to higher indoor temperature set point during hot period and lower indoor temperature set point during cold period than the recommended value. Numerous works have been carried out to show how much energy can be saved during cooling and heating period by applying adaptive comfort temperature. The previous work, however, focused on a continuous cooling load as found in many office and residential buildings. Therefore, this paper aims to simulate the energy saving potential for an academic glazed building in tropical Malaysian climate by developing adaptive cooling technique. A building simulation program (TRNSYS) was used to model the building and simulate the cooling load characteristic using current and proposed technique. Two experimental measurements were conducted and the results were used to validate the model. Finally, cooling load characteristic of the academic building using current and proposed technique were compared and the results showed that annual energy saving potential as much as 305,150 kW h can be achieved

  14. Modelling energy savings in the Danish building sector combined with internalisation of health related externalities in a heat and power system optimisation model

    International Nuclear Information System (INIS)

    Zvingilaite, Erika

    2013-01-01

    A substantial untapped energy saving potential rests in the building sector and is expected to play an important role in achieving reduction of environmental impacts of energy. In order to utilise this potential, effective policy measures need to be adopted to remove the existing barriers and create incentives. For that purpose, the cost effective energy saving options together with an optimal level of savings and expected environmental benefits have to be identified. The paper reports on a study that analyses these questions by including heat-saving measures in buildings into an energy system optimisation model of the Danish heat and power sector. The achieved optimal level of heat savings reaches 11% of projected heat demand in 2025 under the model assumptions. Moreover, the analysis reveals the importance of considering energy conservation options in a system wide perspective. Furthermore, the results suggest that changes in the energy generation sector are the prime driver behind the reduction of environmental externalities of energy. Heat savings in buildings play only a small role under model assumptions. - Highlights: ► Heat savings in buildings are analysed together with a heat and power system. ► Heat savings compete with electricity to heat technologies, mainly heat pumps. ► Cost effective heat-savings bring small decrease in health impacts and CO 2 emissions. ► Cost-effectiveness of heat savings depends on the marginal heat generation technology

  15. Energy savings from operation and maintenance training for apartment boiler heating systems. An energy study on ten low-income apartments

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    The Portland Energy Office provided operation and maintenance (O&M) training to the operators of boiler heating systems for ten low-income apartment complexes in the Fall of 1990. This study tracked energy usage before and after O&M training to see if savings occurred. Training was provided on both weatherized and non-weatherized apartments to find out if weatherization impacted the amount of O&M savings to be obtained. Also, energy savings from the O&M training and building shell weatherization are compared. The O&M training averaged about four hours per building. Content was adjusted at each site to match needs of the boiler and operator. The Energy Office also provided a boiler tune-up by a service technician. The training stressed low-cost and no-cost measures which operators could either do themselves or hire service help to implement. It also emphasized boiler safety. Nine of the ten apartment complexes in the study used less energy per heating degree-day after the O&M help. Average savings were 10%. Four apartments chosen randomly as controls had negative savings; they used slightly more energy during the same post-O&M time frame. Weatherized and unweatherized apartments showed similar savings after the O&M help, 10% and 11% percent respectively. Savings from weatherization of six of the apartments in the winter of 1988--1989 were also measured. A low average of only 4% was observed, reflecting negative savings in two buildings.

  16. When financiers are concerned with energy saving

    International Nuclear Information System (INIS)

    Chauveau, J.

    2005-01-01

    Innovative financial systems allow to finance investments for the energy efficiency improvement of public or residential buildings. Such solutions are implemented in Belgium and Germany. They are based on the association between a financial company, an energy supplier who makes an energy audit and the building owner who refunds the investments with the saving made on the space heating and power consumption of the building. Short paper. (J.S.)

  17. An energy-saving set-point optimizer with a sliding mode controller for automotive air-conditioning/refrigeration systems

    International Nuclear Information System (INIS)

    Huang, Yanjun; Khajepour, Amir; Ding, Haitao; Bagheri, Farshid; Bahrami, Majid

    2017-01-01

    Highlights: • A novel two-layer energy-saving controller for automotive A/C-R system is developed. • A set-point optimizer at the outer loop is designed based on the steady state model. • A sliding mode controller in the inner loop is built. • Extensively experiments studies show that about 9% energy can be saving by this controller. - Abstract: This paper presents an energy-saving controller for automotive air-conditioning/refrigeration (A/C-R) systems. With their extensive application in homes, industry, and vehicles, A/C-R systems are consuming considerable amounts of energy. The proposed controller consists of two different time-scale layers. The outer or the slow time-scale layer called a set-point optimizer is used to find the set points related to energy efficiency by using the steady state model; whereas, the inner or the fast time-scale layer is used to track the obtained set points. In the inner loop, thanks to its robustness, a sliding mode controller (SMC) is utilized to track the set point of the cargo temperature. The currently used on/off controller is presented and employed as a basis for comparison to the proposed controller. More importantly, the real experimental results under several disturbed scenarios are analysed to demonstrate how the proposed controller can improve performance while reducing the energy consumption by 9% comparing with the on/off controller. The controller is suitable for any type of A/C-R system even though it is applied to an automotive A/C-R system in this paper.

  18. Energy supply and energy saving in Ukraine

    Directory of Open Access Journals (Sweden)

    V.M. Ilchenko

    2015-09-01

    Full Text Available The article examines the main problems and solutions of energy saving and energy supply in Ukraine. Low energy efficiency has become one of the main factors of the crisis in the Ukrainian economy. The most relevant scientific and methodical approaches to assessment of the level of energy consumption and saving are indicated. The comparative analysis of annual energy use has been made. A potential to solve energy supply problems is strongly correlated with the ability to ensure the innovative development of economy for efficient and economical use of existing and imported energy resources. The ways for reducing of energy resource consumption have been suggested. Creation of technological conditions for the use of alternative energy sources is considered to be rational also. The development of renewable sources of energy (alternative and renewable energy sources will provide a significant effect in reducing the use of traditional energy sources, harmful emissions and greenhouse gas. Under these conditions, increasing of energy efficiency of economy and its competitiveness can be real. Improvement of environmental and social conditions of citizens of the country will mark a positive step towards the EU, and also will cancel some problems of the future generation.

  19. Energy Savings Measure Packages: Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Casey, S.; Booten, C.

    2011-11-01

    This document presents the most cost effective Energy Savings Measure Packages (ESMP) for existing mixed-fuel and all electric homes to achieve 15% and 30% savings for each BetterBuildings grantee location across the US. These packages are optimized for minimum cost to homeowners for given source energy savings given the local climate and prevalent building characteristics (i.e. foundation types). Maximum cost savings are typically found between 30% and 50% energy savings over the reference home. The dollar value of the maximum annual savings varies significantly by location but typically amounts to $300 - $700/year.

  20. Risk transfer via energy-savings insurance

    International Nuclear Information System (INIS)

    Mills, Evan

    2003-01-01

    Among the key barriers to investment in energy efficiency are uncertainties about attaining projected energy savings and potential disputes over stipulated savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building diagnostics and commissioning), financial methods are less developed in the energy management arena than in other segments of the economy. Energy-savings insurance (ESI) - formal insurance of predicted energy savings - transfers and spreads both types of risk over a larger pool of energy efficiency projects and reduces barriers to market entry of smaller energy service firms who lack sufficiently strong balance sheets to self-insure the savings. ESI encourages those implementing energy-saving projects to go beyond standard measures and thereby achieve more significant levels of energy savings. Insurance providers are proponents of improved savings measurement and verification techniques, as well as maintenance, thereby contributing to national energy-saving objectives. If properly applied, ESI can potentially reduce the net cost of energy-saving projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Governmental agencies have been pioneers in the use of ESI and could continue to play a role

  1. Energy savings in heating systems for nursery pigs; Uso racional de energia eletrica em sistema de aquecimento para creches de leitoes

    Energy Technology Data Exchange (ETDEWEB)

    Sarubbi, Juliana; Rossi, Luiz Antonio; Moura, Daniella Jorge de; Oliveira, Rafael Augustus de; David, Eduardo [Universidade Estadual de Campinas (FEAGRI/UNICAMP), SP (Brazil). Fac. de de Engenharia Agricola], Emails: rossi@feagri.unicamp.br, daniella.moura@feagri.unicamp.br, augustus@feagri.unicamp.br

    2009-07-01

    Energy saving procedures in pig industry are important to bring sustainability to this economic activity. Energy savings can contribute to the economic and environmental feasibility of the livestock and improve animal welfare conditions. This research work aimed to perform a comparison among three heating technologies for nursery pigs related to the energy saving aspects. Three heating systems were studied: TR - suspended electrical resistors, TP - heated floor and TA - convection heating. The heated floor system was considered better than other under the aspect of electrical energy use. (author)

  2. A variable water flow strategy for energy savings in large cooling systems / Gideon Edgar du Plessis

    OpenAIRE

    Du Plessis, Gideon Edgar

    2013-01-01

    Large cooling systems consume up to 25% of the total electricity used on deep level mines. These systems are integrated with the water reticulation system to provide chilled service water and cool ventilation air. Improving the energy efficiency of these large cooling systems is an important electrical demand-side management initiative. However, it is critical that the service delivery and system performance be maintained so as to not adversely affect productivity. A novel dema...

  3. A Review on Energy-Saving Optimization Methods for Robotic and Automatic Systems

    Directory of Open Access Journals (Sweden)

    Giovanni Carabin

    2017-12-01

    Full Text Available In the last decades, increasing energy prices and growing environmental awareness have driven engineers and scientists to find new solutions for reducing energy consumption in manufacturing. Although many processes of a high energy consumption (e.g., chemical, heating, etc. are considered to have reached high levels of efficiency, this is not the case for many other industrial manufacturing activities. Indeed, this is the case for robotic and automatic systems, for which, in the past, the minimization of energy demand was not considered a design objective. The proper design and operation of industrial robots and automation systems represent a great opportunity for reducing energy consumption in the industry, for example, by the substitution with more efficient systems and the energy optimization of operation. This review paper classifies and analyses several methodologies and technologies that have been developed with the aim of providing a reference of existing methods, techniques and technologies for enhancing the energy performance of industrial robotic and mechatronic systems. Hardware and software methods, including several subcategories, are considered and compared, and emerging ideas and possible future perspectives are discussed.

  4. Chinese hotel general managers' perspectives on energy-saving practices

    Science.gov (United States)

    Zhu, Yidan

    As hotels' concern about sustainability and budget-control is growing steadily, energy-saving issues have become one of the important management concerns hospitality industry face. By executing proper energy-saving practices, previous scholars believed that hotel operation costs can decrease dramatically. Moreover, they believed that conducting energy-saving practices may eventually help the hotel to gain other benefits such as an improved reputation and stronger competitive advantage. The energy-saving issue also has become a critical management problem for the hotel industry in China. Previous research has not investigated energy-saving in China's hotel segment. To achieve a better understanding of the importance of energy-saving, this document attempts to present some insights into China's energy-saving practices in the tourist accommodations sector. Results of the study show the Chinese general managers' attitudes toward energy-saving issues and the differences among the diverse hotel managers who responded to the study. Study results indicate that in China, most of the hotels' energy bills decrease due to the implementation of energy-saving equipments. General managers of hotels in operation for a shorter period of time are typically responsible for making decisions about energy-saving issues; older hotels are used to choosing corporate level concerning to this issue. Larger Chinese hotels generally have official energy-saving usage training sessions for employees, but smaller Chinese hotels sometimes overlook the importance of employee training. The study also found that for the Chinese hospitality industry, energy-saving practices related to electricity are the most efficient and common way to save energy, but older hotels also should pay attention to other ways of saving energy such as water conservation or heating/cooling system.

  5. A New Energy-Saving Catalytic System: Carbon Dioxide Activation by a Metal/Carbon Catalyst.

    Science.gov (United States)

    Yun, Danim; Park, Dae Sung; Lee, Kyung Rok; Yun, Yang Sik; Kim, Tae Yong; Park, Hongseok; Lee, Hyunjoo; Yi, Jongheop

    2017-09-22

    The conversion of CO 2 into useful chemicals is an attractive method to reduce greenhouse gas emissions and to produce sustainable chemicals. However, the thermodynamic stability of CO 2 means that a lot of energy is required for its conversion into chemicals. Here, we suggest a new catalytic system with an alternative heating system that allows minimal energy consumption during CO 2 conversion. In this system, electrical energy is transferred as heat energy to the carbon-supported metal catalyst. Fast ramping rates allow high operating temperatures (T app =250 °C) to be reached within 5 min, which leads to an 80-fold decrease of energy consumption in methane reforming using CO 2 (DRM). In addition, the consumed energy normalized by time during the DRM reaction in this current-assisted catalysis is sixfold lower (11.0 kJ min -1 ) than that in conventional heating systems (68.4 kJ min -1 ). © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Energy-saving technical solutions for local and central microclimate systems using heat pumps as local aggregates united into one water circuit

    OpenAIRE

    O.V. Averyanova

    2011-01-01

    One of the priorities of energy savings is to implement energy saving measures in the work of heating systems, heating, ventilation and air conditioning systems based on heat pumps (HP). The dissertation considers using of a multizone central air-conditioning system with chilled beams for increase of power efficiency of a building was offered. In a transition period (the spring, autumn) in a building are observed both surplus of heat in one premises, and shortage of heat in others. At the exp...

  7. Study on the Improvement of Expected Energy Savings and Actual Energy Savings in Apartments

    Directory of Open Access Journals (Sweden)

    Won-Jun Park

    2018-04-01

    Full Text Available Regulating energy consumption can reduce both greenhouse gas emissions and expenditures. In order to maximize efficiency, appropriate energy protocols for buildings must be devised and implemented. This study examines predicted and real energy savings, the differences between them, and the methods which might reduce these discrepancies. Analyses for 195 high-efficiency apartment units (certified based on the energy efficiency rating system in use in Korea indicated an average difference of 23% between predicted and real energy savings. This was found to be due to the fact that predictions failed to take variables such as Heating Type, Corridor Type, and Climate into account. By accounting for these factors, an appropriate calculation formula may be established. Using the revised calculation formula to reevaluate the predicted energy savings of 13 apartment units resulted in a reduction of 7% in the aforementioned discrepancy between predicted and real energy savings. Using the proposed formula to predict energy savings in buildings could improve accuracy, thus facilitating the setting of appropriate standards for restrictions on greenhouse gas emissions of buildings.

  8. Housing-related lifestyle and energy saving

    DEFF Research Database (Denmark)

    Thøgersen, John

    2017-01-01

    in the home and for the energy-consumer’s openness to new energy saving opportunities (i.e., energy saving innovativeness) is investigated. The HRL instrument’s 71 items load on 16 dimensions within five lifestyle elements. Multi-group confirmatory factor analysis reveals that the instrument possesses metric....... However, these two behavioural tendencies vary significantly and substantially between lifestyle segments. The study shows that HRL segmentation is a useful tool for creating more targeted and effective energy-saving campaigns....

  9. Energy saving effect of desiccant ventilation system using Wakkanai siliceous shale

    Science.gov (United States)

    Nabeshima, Yuki; Togawa, Jun-ya; Nagano, Katsunori; Kazuyo, Tsuzuki

    2017-10-01

    The nuclear power station accident resulting from the Great East Japan Earthquake disaster has resulted in a constrained electricity supply. However, in this Asian region there is high temperature and high humidity and consequently dehumidification process requires a huge amount of energy. This is the reason for the increasing energy consumption in the residential and commercial sectors. Accordingly, a high efficiency air-conditioning system is needed to be developed. The desiccant ventilation system is effective to reduce energy consumption for the dehumidification process. This system is capable of dehumidifying without dew condensing unlike a conventional air-conditioning system. Then we focused on Wakkanai Siliceous Shale (WSS) as a desiccant material to develop a new desiccant ventilation system. This is low priced, high performance, new type of thing. The aim of this study is to develop a desiccant ventilation unit using the WSS rotor which can be regenerated with low-temperature by numerical calculation. The results of performance prediction of the desiccant unit, indicate that it is possible to regenerate the WSS rotor at low-temperature of between 35 - 45 °C. In addition, we produced an actual measurement for the desiccant unit and air-conditioning unit. This air-conditioning system was capable to reduce roughly 40 % of input energy consumption.

  10. Energy Savings Measure Packages. Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-11-01

    This document presents the most cost effective Energy Savings Measure Packages (ESMP) for existing mixed-fuel and all electric homes to achieve 15% and 30% savings for each BetterBuildings grantee location across the United States. These packages are optimized for minimum cost to homeowners for source energy savings given the local climate and prevalent building characteristics (i.e. foundation types). Maximum cost savings are typically found between 30% and 50% energy savings over the reference home; this typically amounts to $300 - $700/year.

  11. Management and monitoring of public buildings through ICT based systems: Control rules for energy saving with lighting and HVAC services

    OpenAIRE

    Aghemo, C.; Virgone, J.; Fracastoro, G.V.; Pellegrino, A.; Blaso, L.; Savoyat, J.; Johannes, Kevyn

    2013-01-01

    The presented work addresses the topic of energy savings in existing public buildings, when no significant retrofits on building envelope or plants can be done and savings can be achieved by designing intelligent ICT-based service to monitor and control environmental conditions, energy loads and plants operation. At the end of 2010 the European Commission, within the Seventh Framework Program, has founded a project entitled “Smart Energy Efficient Middleware for Public Spaces” (SEEMPubS). To ...

  12. ENERGY SAVING MODES DEFINITION OF TRAINS HANDLING

    Directory of Open Access Journals (Sweden)

    D. M. Kyslyi

    2016-02-01

    function of traction control of locomotive for the corresponding uniform velocity, which depends on the weight of the train and bias. Practical value. In contrast to existing development of rational management of trains, this function requires much less computing time with a high accuracy of calculations. It allows using the algorithms in the onboard control systems, locomotive and energy savings.

  13. Building automation: Photovoltaic assisted thermal comfort management system for energy saving

    International Nuclear Information System (INIS)

    Khan, M Reyasudin Basir; Jidin, Razali; Shaaya, Sharifah Azwa; Pasupuleti, Jagadeesh

    2013-01-01

    Building automation plays an important key role in the means to reduce building energy consumption and to provide comfort for building occupants. It is often that air conditioning system operating features ignored in building automation which can result in thermal discomfort among building occupants. Most automation system for building is expensive and incurs high maintenance cost. Such system also does not support electricity demand side management system such as load shifting. This paper discusses on centralized monitoring system for room temperature and photovoltaic (PV) output for feasibility study of PV assisted air conditioning system in small office buildings. The architecture of the system consists of PV modules and sensor nodes located at each room. Wireless sensor network technology (WSN) been used for data transmission. The data from temperature sensors and PV modules transmitted to the host personal computer (PC) wirelessly using Zigbee modules. Microcontroller based USB data acquisition device used to receive data from sensor nodes and displays the data on PC.

  14. Building automation: Photovoltaic assisted thermal comfort management system for energy saving

    Science.gov (United States)

    Reyasudin Basir Khan, M.; Jidin, Razali; Pasupuleti, Jagadeesh; Azwa Shaaya, Sharifah

    2013-06-01

    Building automation plays an important key role in the means to reduce building energy consumption and to provide comfort for building occupants. It is often that air conditioning system operating features ignored in building automation which can result in thermal discomfort among building occupants. Most automation system for building is expensive and incurs high maintenance cost. Such system also does not support electricity demand side management system such as load shifting. This paper discusses on centralized monitoring system for room temperature and photovoltaic (PV) output for feasibility study of PV assisted air conditioning system in small office buildings. The architecture of the system consists of PV modules and sensor nodes located at each room. Wireless sensor network technology (WSN) been used for data transmission. The data from temperature sensors and PV modules transmitted to the host personal computer (PC) wirelessly using Zigbee modules. Microcontroller based USB data acquisition device used to receive data from sensor nodes and displays the data on PC.

  15. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    a short account of the technical energy-saving possibilities that are present in existing dwellings and presents a financial methodology used for assessing energy-saving measures. In order to estimate the total savings potential detailed calculations have been performed in a case with two typical...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock......A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...

  16. Energy-saving illumination systems. For administrative buildings, shops, and industrial halls. 2. ed. Energiesparende Beleuchtungsanlagen. Fuer Buerogebaeude, Verkaufsstaetten und Werkhallen

    Energy Technology Data Exchange (ETDEWEB)

    Richter, H.J. (Ingenieurbuero Sonntag und Muehling GmbH, Stuttgart (Germany)); Sonntag, G. (Ingenieurbuero Sonntag und Muehling GmbH, Stuttgart (Germany)); Bouse, D. (Landesgewerbeamt Baden-Wuerttemberg, Stuttgart (Germany))

    1994-08-01

    Almost 40,000 million kWh of electric power are consumed by illumination systems in West Germany every year. In some industrial enterprises, this amounts to 70% of their total electricity consumption. This fact underlines the necessity of saving energy in this field, especially as this would also serve to relieve the environment. This brochure informs on energy-saving illumination systems for offices, production halls, shops and indoor transportation roads. (orig./UA)

  17. Natural gas decompression energy recovery: Energy savings potential in Italy

    International Nuclear Information System (INIS)

    Piatti, A.; Piemonte, C.; Rampini, E.; Vatrano, F.; Techint SpA, Milan; ENEA, Rome

    1992-01-01

    This paper surveyed the natural gas distribution systems employed in the Italian civil, industrial and thermoelectric sectors to identify those installations which can make use of gas decompression energy recovery systems (consisting of turbo-expanders or alternative expanders) to economically generate electric power. Estimates were then made of the total amount of potential energy savings. The study considered as eligible for energy savings interventions only those plants with a greater than 5,000 standard cubic meter per hour plant capacity. It was evaluated that, with suitable decompression equipment installed at 50 key installations (33 civil, 15 industrial), about 200 GWh of power could be produced annually, representing potential savings of about 22,000 petroleum equivalent tonnes of energy. A comparative analysis was done on three investment alternatives involving inputs of varying amounts of Government financial assistance

  18. Energy saving potential in existing industrial compressors

    International Nuclear Information System (INIS)

    Vittorini, Diego; Cipollone, Roberto

    2016-01-01

    The Compressed Air Sector accounts for a mean 10% worldwide electricity consumption, which ensures about its importance, when energy saving and CO 2 emissions reduction are in question. Since the compressors alone account for 15% overall industry electricity consumption, it appears vital to pay attention to machine performances. The paper presents an overview of present compressor technology and focuses on saving directions for screw and sliding vanes machines, according to data provided by the Compressed Air and Gas Institute and PNEUROP. Data were processed to obtain consistency with fixed reference pressures and organized as a function of main operating parameters. Each sub-term, contributing to the overall efficiency (adiabatic, volumetric, mechanical, electric, organic), was considered separately: the analysis showed that the thermodynamic improvement during compression achievable by splitting the compression in two stages, with a lower compression ratio, opens the way to significantly reduce the energy specific consumption. - Highlights: • Compressors technology overview in industrial compressed air systems. • Market compressors efficiency baseline definition. • Energy breakdown and evaluation of main efficiency terms. • Assessment of air cooling-related energy saving potential. • Energy specific consumption reduction through dual stage compression.

  19. Builder System Performance Package Targeting 30% - 40% Savings in Space Conditioning Energy Use: December 2002 - December 2003

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-06-01

    The Consortium for Advanced Residential Building (CARB) describes recommended best practices to achieve 30% - 40% energy savings without compromising health or safety in houses built in cold climates, hot-humid climates, and hot-dry climates.

  20. Performance analysis of proposed hybrid air conditioning and humidification–dehumidification systems for energy saving and water production in hot and dry climatic regions

    International Nuclear Information System (INIS)

    Nada, S.A.; Elattar, H.F.; Fouda, A.

    2015-01-01

    Highlights: • Integrative air-conditioning (A/C) and humidification–dehumidification desalination systems are proposed. • Effects of operating parameters on the proposed systems are investigated. • System configurations that have the highest fresh water production rate, power saving and total cost saving are identified. - Abstract: Performance of integrative air-conditioning (A/C) and humidification–dehumidification desalination systems proposed for hot and dry climatic regions is theoretically investigated. The proposed systems aim to energy saving and systems utilization in fresh water production. Four systems with evaporative cooler and heat recovery units located at different locations are proposed, analyzed and evaluated at different operating parameters (fresh air ratio, supply air temperature and outside air wet bulb temperature). Other two basic systems are used as reference systems in proposed systems assessment. Fresh water production rate, A/C cooling capacity, A/C electrical power consumption, saving in power consumptions and total cost saving (TCS) parameters are used for systems evaluations and comparisons. The results show that (i) the fresh water production rates of the proposed systems increase with increasing fresh air ratio, supply air temperature and outdoor wet bulb temperature, (ii) powers saving of the proposed systems increase with increasing fresh air ratio and supply air temperature and decreasing of the outdoor air wet bulb temperature, (iii) locating the evaporative cooling after the fresh air mixing remarkably increases water production rate, and (vi) incorporating heat recovery in the air conditioning systems with evaporative cooling may adversely affect both of the water production rate and the total cost saving of the system. Comparison study has been presented to identify systems configurations that have the highest fresh water production rate, highest power saving and highest total cost saving. Numerical correlations for

  1. Modeling of Energy-saving System of Conditioning Mine Air for Shallow Underground Mines

    Science.gov (United States)

    Nikolaev, Alexandr; Miftakhov, Timur; Nikolaeva, Evgeniya

    2017-11-01

    Mines of Verkhnekamsk potassium-magnesium salt deposit in Perm Krai can be subsumed under shallow mines (depth less than 500 meters). At the present moment in shallow underground mines the are problem of condensate formation in large quantities, when ventilation warm seasons of the year. This problem is more actual for salt mine, where during contact between water and potassium-magnesium ore produced electrolyte, which give rise wear of equipment. For prevent/quantity reduction condensate formation in mine used system of conditioning (refrigerating and dehumidifying) mine air (ACS). However, application this system is limited by reason of tremendous costs of electric energy for their work.

  2. A switched energy saving position controller for variable-pressure electro-hydraulic servo systems.

    Science.gov (United States)

    Tivay, Ali; Zareinejad, Mohammad; Rezaei, S Mehdi; Baghestan, Keivan

    2014-07-01

    The electro-hydraulic servo system (EHSS) demonstrates a relatively low level of efficiency compared to other available actuation methods. The objective of this paper is to increase this efficiency by introducing a variable supply pressure into the system and controlling this pressure during the task of position tracking. For this purpose, an EHSS structure with controllable supply pressure is proposed and its dynamic model is derived from the basic laws of physics. A switching control structure is then proposed to control both the supply pressure and the cylinder position at the same time, in a way that reduces the overall energy consumption of the system. The stability of the proposed switching control system is guaranteed by proof, and its performance is verified by experimental testing. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  3. User behaviour impact on energy savings potential

    DEFF Research Database (Denmark)

    Rose, Jørgen

    2014-01-01

    When buildings are to undergo energy upgrading in Denmark, the national compliance checker, Be10, is often used to calculate expected energy savings for different energy-saving measures. The Be10 calculation is, however, very dependent on a variety of standard assumptions concerning the building...... and the residents' behaviour and if these defaults do not reflect actual circumstances, it can result in non-realisation of expected energy savings. Furthermore, a risk also exists that residents' behaviour change after the energy upgrading, e.g. to obtain improved comfort than what was possible before...... the upgrading and this could lead to further discrepancies between the calculated and the actual energy savings. This paper presents an analysis on how residents’ behaviour and the use of standard assumptions may influence expected energy savings. The analysis is performed on two typical single-family houses...

  4. Savings in Cooling Energy with a Thermal Management System for LED Lighting in Office Buildings

    Directory of Open Access Journals (Sweden)

    Byung-Lip Ahn

    2015-06-01

    Full Text Available Light-emitting diode (LED lighting should be considered for lighting efficiency enhancement, however, waste heat from light-emitting diode (LED lighting increases the internal cooling load during the summer season. In order to solve this problem we propose a thermal management system for light-emitting diode (LED lighting with a heat exchanger module integrated with the building’s heating, ventilation, and air conditioning (HVAC system to move the lighting’s waste heat outdoors. An experiment was carried out to investigate the thermal effects in a test chamber and the heat exchange rate between the heat sink and the duct air. The heat generated by the light-emitting diode (LED lighting was calculated as 78.1% of light-emitting diode (LED input power and the heat exchange rate of the lighting heat exchange module was estimated to be between 86.5% and 98.1% according to the light-emitting diode (LED input power and the flow rate of air passing the heat sink. As a result, the average light-emitting diode (LED lighting heat contribution rate for internal heat gain was determined as 0.05; this value was used to calculate the heating and cooling energy demand of the office building through an energy simulation program. In the simulation results, the cooling energy demand was reduced by 19.2% compared with the case of conventionally installed light-emitting diode (LED lighting.

  5. An automatic energy-saving and thermal monitoring/controlling system for a pond

    Directory of Open Access Journals (Sweden)

    Cheng Ching-Chien

    2017-01-01

    Full Text Available Because of low temperatures and oxygen in cold water, fish will die when cold currents arrive. This will cause tremendous loss of money. In order reduce the cooling of the pond, an automatic thermal detecting and cold-roofing system using a wind-proofing device, heaters, and thermal detectors is proposed. To reduce heat loss due to thermal convection above the pond surface, a motor-driven wind-proofing device automatically controlled by a PLC controller is adopted. Here, the wind-proofing device, thermal detectors, and heating system are connected to the PLC controller. The PLC will also be connected to the PC interface. The temperature thresholds used to trigger the heater and the wind proofing device can be set at the PC interface. Two options for manipulating the heating and the automatic heating can be selected. The related wind-proofing area and the number of heaters will be determined according to the current temperature. Moreover, the PLC can be wirelessly connected to the server PC in the control room. The pond keeper can monitor everything online and control the pond water's temperature. With this, the problem of fish dying in a cold wave can be solved. Consequently, to reduce the electrical exhaust when heating up the pond water, green energy, solar energy and wind energy, is used.

  6. Energy Savers Tips on Saving Energy& Money at Home

    Energy Technology Data Exchange (ETDEWEB)

    2003-06-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances

  7. Energy Savers: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-12-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  8. Energy Saver: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  9. Energy Savers: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-05-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  10. FY 1999 report on energy conservation potential survey of measurement and control systems and energy-saving equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Studies are conducted with a view to connecting a survey in Egypt to CDM (clean development mechanism) adopted at COP3 (Third Session of the Conference of the Parties to the United Nations Framework Convention on Climate Change). The survey covers the textile industry which is one of Egypt's main industries, and investigation is conducted for extending technical recommendation to 11 textile mills (including dyeing plants) about how to reduce greenhouse gas (CO2) emissions through energy conservation efforts. Required investment, investment recovery period, and reduction in CO2 emissions are calculated. About CO2 reduction, it is found that there will be a CO2 reduction of 44,702 tons/year at a rate of 22.4%, investment of 838.56-million yen, CO2 reduction of 53.3 tons/million yen, and investment of 18,750-yen/t-CO2. As for energy conservation, there will be a reduction at a rate of 14,449 toe/year in energy consumption, investment of 838.56-million yen, energy saved at a rate of 17.2 toe/million yen, and investment of 5,800 yen/toe. There will be an annual reduction in utility cost of 125.79-million yen at a cost reduction rate of 10.3%. The investment recovery period is calculated to be 5.8 years. The Egyptian textile has high potentials for CO2 reduction, and will present an excellent opportunity for a CDM project. (NEDO)

  11. Smart buildings: an energy saving and control system in the CNR Research Area, Pisa

    OpenAIRE

    Barsocchi, Paolo; Crivello, Antonino; Ferro, Erina; Fortunati, Luigi; Mavilia, Fabio; Riolo, Giancarlo

    2014-01-01

    "Renewable Energy and ICT for Sustainability Energy" (or "Energy Sustainability") is a project led by the Department of Engineering, ICT, and Technologies for Energy and Transportations (DIITET) of the Italian National Research Council (CNR). This project aims to study and test a coordinated set of innovative solutions to make cities sustainable, with respect to their energy consumption.

  12. Factors underlying the investment decision in energy-saving systems in Dutch horticulture

    NARCIS (Netherlands)

    Aramyan, L.H.; Oude Lansink, A.G.J.M.; Verstegen, J.A.A.M.

    2007-01-01

    In the Netherlands the greenhouse sector is a major user of energy. It accounts for 7% of the total national energy use and for 79% of the total energy use in agriculture. In order to sustain this sector on the long term, it is important that its use of energy is lowered. One way of reducing energy

  13. Risk transfer via energy savings insurance

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan

    2001-10-01

    Among the key barriers to investment in energy efficiency improvements are uncertainties about attaining projected energy savings and apprehension about potential disputes over these savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building commissioning), financial risk transfer techniques are less developed in the energy management arena than in other more mature segments of the economy. Energy Savings Insurance (ESI) - formal insurance of predicted energy savings - is one method of transferring financial risks away from the facility owner or energy services contractor. ESI offers a number of significant advantages over other forms of financial risk transfer, e.g. savings guarantees or performance bonds. ESI providers manage risk via pre-construction design review as well as post-construction commissioning and measurement and verification of savings. We found that the two mos t common criticisms of ESI - excessive pricing and onerous exclusions - are not born out in practice. In fact, if properly applied, ESI can potentially reduce the net cost of energy savings projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Debt service can also be ensured by matching loan payments to projected energy savings while designing the insurance mechanism so that payments are made by the insurer in the event of a savings shortfall. We estimate the U.S. ESI market potential of $875 million/year in premium income. From an energy-policy perspective, ESI offers a number of potential benefits: ESI transfers performance risk from the balance sheet of the entity implementing the energy savings project, thereby freeing up capital otherwise needed to ''self-insure'' the savings. ESI reduces barriers to market entry of smaller energy services firms who do not have sufficiently strong balance

  14. Risk transfer via energy savings insurance; TOPICAL

    International Nuclear Information System (INIS)

    Mills, Evan

    2001-01-01

    Among the key barriers to investment in energy efficiency improvements are uncertainties about attaining projected energy savings and apprehension about potential disputes over these savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building commissioning), financial risk transfer techniques are less developed in the energy management arena than in other more mature segments of the economy. Energy Savings Insurance (ESI) - formal insurance of predicted energy savings - is one method of transferring financial risks away from the facility owner or energy services contractor. ESI offers a number of significant advantages over other forms of financial risk transfer, e.g. savings guarantees or performance bonds. ESI providers manage risk via pre-construction design review as well as post-construction commissioning and measurement and verification of savings. We found that the two mos t common criticisms of ESI - excessive pricing and onerous exclusions - are not born out in practice. In fact, if properly applied, ESI can potentially reduce the net cost of energy savings projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Debt service can also be ensured by matching loan payments to projected energy savings while designing the insurance mechanism so that payments are made by the insurer in the event of a savings shortfall. We estimate the U.S. ESI market potential of$875 million/year in premium income. From an energy-policy perspective, ESI offers a number of potential benefits: ESI transfers performance risk from the balance sheet of the entity implementing the energy savings project, thereby freeing up capital otherwise needed to ''self-insure'' the savings. ESI reduces barriers to market entry of smaller energy services firms who do not have sufficiently strong balance sheets to self

  15. Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Modeling and Installation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Thomas; Liu, Zan; Sickinger, David; Regimbal, Kevin; Martinez, David

    2017-02-01

    The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device, the thermosyphon cooler (TSC), with an open cooling tower. A combination of equipment and controls, this new heat rejection system embraces the 'smart use of water,' using evaporative cooling when it is most advantageous and then saving water and modulating toward increased dry sensible cooling as system operations and ambient weather conditions permit. Innovative fan control strategies ensure the most economical balance between water savings and parasitic fan energy. The unique low-pressure-drop design of the TSC allows water to be cooled directly by the TSC evaporator without risk of bursting tubes in subfreezing ambient conditions. Johnson Controls partnered with the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to deploy the TSC as a test bed at NREL's high-performance computing (HPC) data center in the first half of 2016. Located in NREL's Energy Systems Integration Facility (ESIF), this HPC data center has achieved an annualized average power usage effectiveness rating of 1.06 or better since 2012. Warm-water liquid cooling is used to capture heat generated by computer systems direct to water; that waste heat is either reused as the primary heat source in the ESIF building or rejected using evaporative cooling. This data center is the single largest source of water and power demand on the NREL campus, using about 7,600 m3 (2.0 million gal) of water during the past year with an hourly average IT load of nearly 1 MW (3.4 million Btu/h) -- so dramatically reducing water use while continuing efficient data center operations is of significant interest. Because Sandia's climate is similar to NREL's, this new heat rejection system being deployed at NREL has gained interest at Sandia. Sandia's data centers utilize an hourly average of 8.5 MW (29 million Btu/h) and are also one of the largest consumers of

  16. 78 FR 20097 - Energy Savings Performance Contracts

    Science.gov (United States)

    2013-04-03

    ... implement energy savings projects where the up-front capital cost is financed by an Energy Services Company... since 1996. DOE is publishing this RFI to obtain ideas and input from ESPC [[Page 20098

  17. Low-Cost and Energy-Saving Wireless Sensor Network for Real-Time Urban Mobility Monitoring System

    Directory of Open Access Journals (Sweden)

    Joyoung Lee

    2015-01-01

    Full Text Available This paper presents a low-cost and energy-saving urban mobility monitoring system based on wireless sensor networks (WSNs. The primary components of the proposed sensor unit are a Bluetooth sensor and a Zigbee transceiver. Within the WSN, the Bluetooth sensor captures the MAC addresses of Bluetooth units equipped in mobile devices and car navigation systems. The Zigbee transceiver transmits the collected MAC addresses to a data center without any major communications infrastructures (e.g., fiber optics and 3G/4G network. A total of seven prototype sensor units have been deployed on roadway segments in Newark, New Jersey, for a proof of concept (POC test. The results of the POC test show that the performance of the proposed sensor unit appears promising, resulting in 2% of data drop rates and an improved Bluetooth capturing rate.

  18. Contemporary energy storage sources. Energy saving

    International Nuclear Information System (INIS)

    Manev, Veselin

    2011-01-01

    The development of renewable energy system for electricity production is impede because of needs to be stabilized with nearly equivalent installed power of energy storage devices. The development of more electrical energy storage facilities will be extremely important for electricity generation in the future. Using hydro pumping, combined with a long life and fast charge/discharge rate, highly efficient contemporary power energy storage as Altairnano lithium ion battery, currently is seems to be the best solution for fast penetration rate of wind and solar energy systems

  19. User behaviour impact on energy savings potential

    DEFF Research Database (Denmark)

    Rose, Jørgen

    2014-01-01

    and the residents' behaviour and if these defaults do not reflect actual circumstances, it can result in non-realisation of expected energy savings. Furthermore, a risk also exists that residents' behaviour change after the energy upgrading, e.g. to obtain improved comfort than what was possible before...... the upgrading and this could lead to further discrepancies between the calculated and the actual energy savings. This paper presents an analysis on how residents’ behaviour and the use of standard assumptions may influence expected energy savings. The analysis is performed on two typical single-family houses......, 3) Domestic hot water consumption and 4) Air change rate. Based on the analysis, a methodology is established that can be used to make more realistic and accurate predictions of expected energy savings associated with energy upgrading taking into account user behaviour....

  20. Analysis of Applications to Improve the Energy Savings in Residential Buildings Based on Systemic Quality Model

    Directory of Open Access Journals (Sweden)

    Antoni Fonseca i Casas

    2016-10-01

    Full Text Available Creating a definition of the features and the architecture of a new Energy Management Software (EMS is complex because different professionals will be involved in creating that definition and in using the tool. To simplify this definition and aid in the eventual selection of an existing EMS to fit a specific need, a set of metrics that considers the primary issues and drawbacks of the EMS is decisive. This study proposes a set of metrics to evaluate and compare EMS applications. Using these metrics will allow professionals to highlight the tendencies and detect the drawbacks of current EMS applications and to eventually develop new EMS applications based on the results of the analysis. This study presents a list of the applications to be examined and describes the primary issues to be considered in the development of a new application. This study follows the Systemic Quality Model (SQMO, which has been used as a starting point to develop new EMS, but can also be used to select an existing EMS that fits the goals of a company. Using this type of analysis, we were able to detect the primary features desired in an EMS software. These features are numerically scaled, allowing professionals to select the most appropriate EMS that fits for their purposes. This allows the development of EMS utilizing an iterative and user-centric approach. We can apply this methodology to guide the development of future EMS and to define the priorities that are desired in this type of software.

  1. Energy Savings in a Market Economy

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1998-01-01

    suppliers. The recently debated case of building a new combined heat and powerplants because of the need for the "waste" heat is discussed on the background of a couple of decades of ignoring heat savings. The open and more hidden conflict between a quest for economic growth and energy savings are described...

  2. Energy saving certificates; Les certificats d'economies d'energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-11-15

    The French ministry of economy, finances and industry and the French agency of environment and energy mastery (Ademe) have organized on November 8, 2005, a colloquium for the presentation of the energy saving certificates, a new tool to oblige the energy suppliers to encourage their clients to make energy savings. This document gathers the transparencies presented at this colloquium about the following topics: state-of-the-art and presentation of the energy saving certificates system: presentation of the EEC system, presentation of the EEC standard operations; the energy saving certificates in Europe today: energy efficiency commitment in UK, Italian white certificate scheme, perspectives of the different European systems. (J.S.)

  3. Application of Autonomous Smart Inverter Volt-VAR Function for Voltage Reduction Energy Savings and Power Quality in Electric Distribution Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Nagarajan, Adarsh; Baggu, Murali; Chakraborty, Sudipta; Nguyen, Andu; Walinga, Sarah; McCarty, Michael; Bell, Frances

    2017-05-01

    This paper evaluated the impact of smart inverter Volt-VAR function on voltage reduction energy saving and power quality in electric power distribution systems. A methodology to implement the voltage reduction optimization was developed by controlling the substation LTC and capacitor banks, and having smart inverters participate through their autonomous Volt-VAR control. In addition, a power quality scoring methodology was proposed and utilized to quantify the effect on power distribution system power quality. All of these methodologies were applied to a utility distribution system model to evaluate the voltage reduction energy saving and power quality under various PV penetrations and smart inverter densities.

  4. SWEEP - Save Water & Energy Education Program

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Gregory P.; Elliott, Douglas B.; Hillman, Tim C.; Hadley, Adam; Ledbetter, Marc R.; Payson, David R.

    2001-05-03

    The objective of this study was to develop, monitor, analyze, and report on an integrated resource-conservation program highlighting efficient residential appliances and fixtures. The sites of study were 50 homes in two water-constrained communities located in Oregon. The program was designed to maximize water savings to these communities and to serve as a model for other communities seeking an integrated approach to energy and water resource efficiency. The program included the installation and in-place evaluation of energy- and water-efficient devices including the following: horizontal axis clothes washers (and the matching clothes dryers), resource-efficient dishwashers, an innovative dual flush low-flow toilet, low-flow showerheads, and faucet aerators. The significance of this activity lies in its integrated approach and unique metering evaluation of individual end-use, aggregated residential total use, and system-wide energy and water benefits.

  5. Public-opinion poll on energy saving

    International Nuclear Information System (INIS)

    1982-01-01

    A public-opinion poll was carried out on energy saving from November 26 to December 2, 1981, across the country. The number of persons participated in the survey was 5,000, whose age was 20 and above. The recovery ratio was 4,007 persons (80.1 %). The results of the survey and also the question-answer form are given with respective percentages. The questions were in the following three categories: (1) cognizance of energy saving - space-heating temperature, energy saving conscience use of private cars, purchase of highenergy consumption appliances; (2) energy for future - energy consumption, energy consumption trend, new types of energy, main sources of power generation, nuclear power in the overall electric power, apprehension toward nuclear power plants, safety measures in nuclear power plants; (3) governmental energy policy measures. (J.P.N.)

  6. Control Evaluation Information System Savings

    Directory of Open Access Journals (Sweden)

    Eddy Sutedjo

    2011-05-01

    Full Text Available The purpose of this research is to evaluate the control of information system savings in the banking and to identify the weaknesses and problem happened in those saving systems. Research method used are book studies by collecting data and information needed and field studies by interview, observation, questioner, and checklist using COBIT method as a standard to assess the information system control of the company. The expected result about the evaluation result that show in the problem happened and recommendation given as the evaluation report and to give a view about the control done by the company. Conclusion took from this research that this banking company has met standards although some weaknesses still exists in the system.Index Terms - Control Information System, Savings

  7. Behaviour : Seeing heat saves energy

    NARCIS (Netherlands)

    Steg, Linda

    2016-01-01

    Household energy conservation can help to significantly lower energy consumption. Visual cues provided by thermal imaging of heat loss in buildings are now shown to increase energy conserving behaviours and implementations among homeowners more effectively than just performing carbon footprint

  8. Values and Technologies in Energy Savings

    DEFF Research Database (Denmark)

    Nørgård, Jørgen Stig

    2000-01-01

    of this saving can cause what is called the rebound effect, which reduces the savings obtained from the technology. Ways to avoid this effect are suggested, and they require value changes, primarly around frugality, consumption, and hard-working. There are indications that some of the necessary changes are well......The chapter is based on the assumption, that technology improvement is not sufficient to achieve a sustainable world community. Changes in people´s values are necessary. A simple model suggest how values, together with basic needs and with the environmental and societal frames, determine people......´s behavioural pattern and lifestyles. Deliberate changes in social values are illustrated by a historical example. From the side of technology the basic principles in the economy of energy savings are briefly described. The marginally profitable energy savings provides an economic saving. The application...

  9. Advanced Energy Saving and its Applications in Industry

    CERN Document Server

    Matsuda, Kazuo; Fushimi, Chihiro; Tsutsumi, Atsushi; Kishimoto, Akira

    2013-01-01

    The conventional approach for energy saving in a process system is to maximize heat recovery without changing any process conditions by using pinch technology. “Self-heat recuperation technology” was developed to achieve further energy saving in the process system by eliminating the necessity for any external heat input, such as firing or imported steam. Advanced Energy Saving and its Applications in Industry introduces the concept of self-heat recuperation and the application of such technology to a wide range of processes from heavy chemical complexes to other processes such as drying and gas separation processes, which require heating and cooling during operation.   Conventional energy saving items in a utility system are applied and implemented based on a single site approach, however, when looking at heavy chemical complexes, it was apparent that the low-grade heat discharged as waste from a refinery could also be used in an adjacent petrochemical plant. There could therefore be a large energy savin...

  10. Save Maritime Systems Testbed

    Directory of Open Access Journals (Sweden)

    Bolles André

    2014-06-01

    Full Text Available ‘Safe voyage from berth to berth’ — this is the goal of all e-navigation strains, driven by new technologies, new infrastructures and new organizational structures on bridge, on shore as well as in the cloud. To facilitate these efforts suitable engineering and safety/risk assessment methods have to be applied. Understanding maritime transportation as a sociotechnical system allows system engineering methods to be applied. Formal and simulation based verification and validation of e-navigation technologies are important methods to obtain system safety and reliability. The modelling and simulation toolset HAGGIS provides methods for system specification and formal risk analysis. It provides a modelling framework for processes, fault trees and generic hazard specification and a physical world and maritime traffic simulation system. HAGGIS is accompanied by the physical test bed LABSKAUS which implements a reference port and waterway. Additionally, it contains an experimental Vessel Traffic Services (VTS implementation and a mobile integrated bridge enabling in situ experiments for technology evaluation, testing, ground research and demonstration. This paper describes an integrated seamless approach for developing new e-navigation technologies starting with virtual simulation based assessment and ending in physical real world demonstrations.

  11. Marketing strategy - sales system for energy saving technology in the heat market

    Energy Technology Data Exchange (ETDEWEB)

    Dommann, D.

    1984-06-04

    Modern industrial society is undergoing a period of upheaval which is sparing no company. Today's greatest challenge to management is to get this transition under control. The process of change inevitably effects marketing policies and company employees. There are doubtlessly many viable marketing strategies available, but they are of little use if they cannot be applied in the market by qualified personnel. In this article the author gives suggestions for selling energy conserving technology in today's heat market using a systematic sales method.

  12. Energy-Saving Automation and LED Lighting Systems in Industry, Transport, Building and Municipal Sector

    Directory of Open Access Journals (Sweden)

    V.P. Klimenko

    2013-09-01

    Full Text Available Protocol of diverse technological data unification providing the ability to scale with a minimal increase in auxiliary information volume that allows its usage, ranging from the simplest microcontrollers to integration of automation equipment in global systems was designed for industrial automation systems. Basic technical solutions implemented in development of LED lighting systems of salon subway cars, including a schematic diagram of the lamp, the main technical characteristics of the lamp power supply, the peculiarities of developed design of LED modules are described.

  13. Short Communication: Electrical energy saving through lamps ...

    African Journals Online (AJOL)

    Modern Buildings of all types relies heavily on the use of electrical energy. This energy has to be properly utilized in order to avoid many problems both to the electric utilities supply companies and also to the consumer. This paper presents energy saving through replacement process of conventional electric lamps known ...

  14. Energy-saving Lighting Technology of Petrochemical Enterprises

    Directory of Open Access Journals (Sweden)

    Baohu Gu

    2015-12-01

    Full Text Available The shortage of energy resources is a serious problem our country is facing the world today, petrochemical enterprises are the main pillar of our economy, in our country, because petrochemical companies accounted for about 30.2% of the total energy consumption of energy. This paper focuses on the traditional energy-saving lighting methods proposed intelligent energy-saving system based on a fuzzy control. The purpose is to make the electrical equipment to fully meet, under the premise of improving its functional requirements, as far as possible to reduce energy consumption and improve energy efficiency.

  15. Savings impact of a corporate energy manager

    International Nuclear Information System (INIS)

    Sikorski, B.D.; O'Donnell, B.A.

    1999-01-01

    This paper discusses the cost savings impact of employing an energy manager with a 16,000-employee corporation. The corporation, Canada's second largest airline, is currently operating nearly 3,000,000 ft 2 of mixed-use facilities spread across the country, with an annual energy budget for ground facilities of over Cdn $4,000,000. This paper outlines the methodology used by the energy manager to deploy an energy management program over a two-year period between April 1995 and May 1997. The paper examines the successes and the lessons learned during the period and summarizes the costs and benefits of the program. The energy manager position was responsible for developing an energy history database with more than 100 active accounts and for monitoring and verifying energy savings. The energy manager implemented many relatively low-cost energy conservation measures, as well as some capital projects, during the first two years of the program. In total, these measures provided energy cost savings of $210,000 per year, or 5% of the total budget. In each case, technologies installed as part of the energy retrofit projects provided not only cost savings but also better control, reduced maintenance, and improved working conditions for employees

  16. Planning of the district heating system in copenhagen from an economic perspective comparing energy-savings versus fossil-free supply

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    geothermal heating plants, may lead to oversized heating plants that are too expensive to build compared to implementing energy savings. Therefore reducing heat demand of existing buildings before investing in supply capacity will save society half the investment, indicating the importance of carrying out......The Danish government has adopted a long-term energy policy of being independent of fossil fuels by 2050, and that the energy supply for buildings should be independent of fossil fuels by 2035. Therefore, urgent action is needed to meet the requirements for the future energy system. One way...... of becoming independent of fossil fuels is to energy upgrade the existing building stock and change the energy supply to renewable energy sources. A sustainable way of providing space heating (SH) and domestic hot water (DHW) to buildings in densely populated areas is through the use of district heating (DH...

  17. Negotiated agreements - blueprint for energy saving

    International Nuclear Information System (INIS)

    Stacey, K.

    2001-01-01

    A 5-step model for achieving energy saving targets which are set out in Climate Change Levy (CCL) Negotiated Agreements is presented. The model for energy management and conservation entails the development of an energy policy, planning and organising involving formalised responsibilities for achieving the objectives of the energy policy, monitoring and control of plans, management reports on energy use, and regular reviews. Web addresses for CCL documents and information are provided

  18. A technical analysis for cogeneration systems with potential applications in twelve California industrial plants. [energy saving heat-electricity utility systems

    Science.gov (United States)

    Moretti, V. C.; Davis, H. S.; Slonski, M. L.

    1978-01-01

    In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass

  19. Energy Savings from Industrial Water Reductions

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Prakash; McKane, Aimee; de Fontaine, Andre

    2015-08-03

    Although it is widely recognized that reducing freshwater consumption is of critical importance, generating interest in industrial water reduction programs can be hindered for a variety of reasons. These include the low cost of water, greater focus on water use in other sectors such as the agriculture and residential sectors, high levels of unbilled and/or unregulated self-supplied water use in industry, and lack of water metering and tracking capabilities at industrial facilities. However, there are many additional components to the resource savings associated with reducing site water use beyond the water savings alone, such as reductions in energy consumption, greenhouse gas emissions, treatment chemicals, and impact on the local watershed. Understanding and quantifying these additional resource savings can expand the community of businesses, NGOs, government agencies, and researchers with a vested interest in water reduction. This paper will develop a methodology for evaluating the embedded energy consumption associated with water use at an industrial facility. The methodology developed will use available data and references to evaluate the energy consumption associated with water supply and wastewater treatment outside of a facility’s fence line for various water sources. It will also include a framework for evaluating the energy consumption associated with water use within a facility’s fence line. The methodology will develop a more complete picture of the total resource savings associated with water reduction efforts and allow industrial water reduction programs to assess the energy and CO2 savings associated with their efforts.

  20. Saving energy: bringing down Europe's enery prices

    NARCIS (Netherlands)

    Molenbroek, E.; Blok, K.

    2012-01-01

    In June 2011 the European Commission proposed a new Directive on Energy Efficiency. Its purpose is to put forward a framework to deliver the EU’s target of reducing its energy consumption by 20% by 2020. Currently, the EU is only on track to achieve half of those savings. Apart from the

  1. Daylight metrics and energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Mardaljevic, John; Heschong, Lisa; Lee, Eleanor

    2009-12-31

    The drive towards sustainable, low-energy buildings has increased the need for simple, yet accurate methods to evaluate whether a daylit building meets minimum standards for energy and human comfort performance. Current metrics do not account for the temporal and spatial aspects of daylight, nor of occupants comfort or interventions. This paper reviews the historical basis of current compliance methods for achieving daylit buildings, proposes a technical basis for development of better metrics, and provides two case study examples to stimulate dialogue on how metrics can be applied in a practical, real-world context.

  2. Electric energy savings from new technologies

    Energy Technology Data Exchange (ETDEWEB)

    Moe, R.J.; Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.; Imhoff, K.L.; Fisher, Z.J.

    1986-01-01

    Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for ten technologies were prepared. The total projected annual savings for the year 2000 for all ten technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In the Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Thus, the savings projected here represent between 4% and 14% of total consumption projected for 2000. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference forecast, reducing projected electricity consumption from what it otherwise would have been, the savings estimated here should not be directly subtracted from the reference forecast.

  3. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  4. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Young, Jim [Navigant Consulting, Inc., Burlington, MA (United States); Schmidt, Justin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-10-01

    This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  5. Technical Support Document: 50% Energy Savings for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  6. Verification of electricity savings through energy-efficient train management - Concept and system architecture - Annex 1; Verifizierung der Stromeinsparung durch energieeffizientes Zugsmanagement - Anhang 1: Konzept und Systemarchitektur

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, M.; Lerjen, M.; Menth, S. [emkamatik GmbH, Wettingen (Switzerland); Luethi, M. [Swiss Federal Insitute of Technology (ETHZ), Institute for Transport Planning and Systems (IVT), Zuerich (Switzerland); Tuchschmid, M. [SBB AG, BahnUmwelt-Center, 3000 Bern (Switzerland)

    2009-11-15

    This appendix to a final report for the Swiss Federal Office of Energy (SFOE) discusses a system concept that can be used to help save energy in the Swiss rail network. The concept proposes that the highest level of energy savings can be achieved by controlling the trains to provide a high level of smooth flow as far as speed is concerned. In particular, various situations are described where, for example, double and single track working exists and unnecessary breaking when trains have to pass each other can be avoided. Predictor algorithms are described and discussed and possible indicators for train drivers are proposed. The system architecture required is examined and recommendations are made concerning the implementation of the system. Restrictions caused by the running of non-equipped foreign trains on the Swiss rail network are also discussed.

  7. Investigating Energy-Saving Potentials in the Cloud

    Science.gov (United States)

    Lee, Da-Sheng

    2014-01-01

    Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI) of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D) data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit. PMID:24561405

  8. Investigating energy-saving potentials in the cloud.

    Science.gov (United States)

    Lee, Da-Sheng

    2014-02-20

    Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI) of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D) data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit.

  9. Energy Savings Performance Contract Energy Sales Agreement Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-08-14

    FEMP developed the Energy Savings Performance Contracting Energy Sales Agreement (ESPC ESA) Toolkit to provide federal agency contracting officers and other acquisition team members with information that will facilitate the timely execution of ESPC ESA projects.

  10. A review of different strategies for HVAC energy saving

    International Nuclear Information System (INIS)

    Vakiloroaya, Vahid; Samali, Bijan; Fakhar, Ahmad; Pishghadam, Kambiz

    2014-01-01

    Highlights: • Various strategies for HVAC energy saving are described and reviewed. • The influence of each strategy on the HVAC energy saving is investigated. • Combination of existing air conditioning technologies appears to be effective for the energy conservation and comfort. • A comparison study between these approaches is carried out. • Changing the HVAC configuration has the potential to increase or reduce energy savings, depending on several factors. - Abstract: Decreasing the energy consumption of heating, ventilation and air conditioning (HVAC) systems is becoming increasingly important due to rising cost of fossil fuels and environmental concerns. Therefore, finding novel ways to reduce energy consumption in buildings without compromising comfort and indoor air quality is an ongoing research challenge. One proven way of achieving energy efficiency in HVAC systems is to design systems that use novel configurations of existing system components. Each HVAC discipline has specific design requirements and each presents opportunities for energy savings. Energy efficient HVAC systems can be created by re-configuring traditional systems to make more strategic use of existing system parts. Recent research has demonstrated that a combination of existing air conditioning technologies can offer effective solutions for energy conservation and thermal comfort. This paper investigates and reviews the different technologies and approaches, and demonstrates their ability to improve the performance of HVAC systems in order to reduce energy consumption. For each strategy, a brief description is first presented and then by reviewing the previous studies, the influence of that method on the HVAC energy saving is investigated. Finally, a comparison study between these approaches is carried out

  11. Tip Saves Energy, Money for Pennsylvania Plant

    Science.gov (United States)

    A wastewater treatment plant in Berks County, Pennsylvania is saving nearly $45,000 a year and reducing hundreds of metric tons of greenhouse gases since employing an energy conservation tip offered by the Water Protection Division in EPA’s R3 and PADEP.

  12. Energy saving estimation on radiation process

    International Nuclear Information System (INIS)

    Kinuta, Hidetoshi

    1982-01-01

    The Irradiation Application Group, Radiation Utilization Study Committee, Japan Atomic Industrial Forum Inc., has examined radiation process from the viewpoint of energy saving for one year. In this paper, the results related to the cross-linking of cable coating and rubber are reported. In these fields, the chemical cross-linking is made generally by mixing cross-linking agents in raw materials and passing through the atmosphere with large heat source, but the effect of energy saving when this process is substituted with electron beam cross-linking was calculated for trial. The application of electron beam irradiation to the reform of cable coating has been carried out from old time, but it is mostly for appliance wires of up to 1.5 mm thickness, and it has not been applied to high voltage power cables. The present state of the cross-linking method for high voltage power cables, the comparison of electron beam cross-linking and other methods from the viewpoint of energy saving and others are described. It was shown that the electron beam cross-linking is very effective means for energy saving, but the actual application in Japan is still few. (Kako, I.)

  13. Reactors Save Energy, Costs for Hydrogen Production

    Science.gov (United States)

    2014-01-01

    While examining fuel-reforming technology for fuel cells onboard aircraft, Glenn Research Center partnered with Garrettsville, Ohio-based Catacel Corporation through the Glenn Alliance Technology Exchange program and a Space Act Agreement. Catacel developed a stackable structural reactor that is now employed for commercial hydrogen production and results in energy savings of about 20 percent.

  14. Energy saving estimation on radiation process

    International Nuclear Information System (INIS)

    Kaneko, Hideaki; Maekawa, H.; Ito, Y.; Nishikawa, I.; Fujii, H.; Murata, K.

    1982-01-01

    When the quantity of paint used for industrial coating is assumed to be 420,000 tons, it is estimated that the area being coated is 2.8 billion m 2 , the petroleum required for pretreatment steam, drying and baking is 1.68 million tons, and the required amount of energy saving is 120,000 tons per year in terms of petroleum. The authors examined how the adoption of electron beam curing for surface coating contributes to the energy saving. So far, it has been said that electron beam curing is more efficient than thermal or light curing in energy consumption, but the premise condition was not clear. The theoretical energy requirement for thermal curing, light curing and electron beam curing was calculated and compared. The comparison of the measured values was also performed. The amount of energy required for thermal curing, UV light curing and electron beam curing was roughly 100:10:1, and the cost of energy for them was 50:5:1. In spite of the large merit of electron beam curing, it has not spread as expected, because of the repayment cost of the facility and the cost of inert gas required for the process. Energy saving is brought about by electron beam curing, but the overall cost must be examined case by case. (Kako, I.)

  15. Energy saving strategies in an actual confectionery plant

    Energy Technology Data Exchange (ETDEWEB)

    Grimaldi, C.N.; Lunghi, P.; Mariani, F. [Universita di Perugia, Dip. di Ingegneria Industriale, Perugia (Italy)

    2000-07-01

    The achievements of a more rational use of energy can be difficult when large and complex industrial plants are considered. In the present work, an example is given of how a well-focused energy analysis, based on experimental data, can help to point out possible relevant energy savings. In particular, two different refrigeration systems have been examined for a confectionery plant in different seasons, atmospheric and production conditions, allowing us to understand the actual operation. Based on the analysis of the results, energy saving strategies have been proposed and discussed. (Author)

  16. Predictive Maintenance (PdM) Centralization for Significant Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Dale

    2010-09-15

    Cost effective predictive maintenance (PdM) technologies and basic energy calculations can mine energy savings form processes or maintenance activities. Centralizing and packaging this information correctly empowers facility maintenance and reliability professionals to build financial justification and support for strategies and personnel to weather global economic downturns and competition. Attendees will learn how to: Systematically build a 'pilot project' for applying PdM and tracking systems; Break down a typical electrical bill to calculate energy savings; Use return on investment (ROI) calculations to identify the best and highest value options, strategies and tips for substantiating your energy reduction maintenance strategies.

  17. Structured packing: an opportunity for energy savings

    International Nuclear Information System (INIS)

    Chavez T, R.H.; Guadarrama G, J.J.

    1996-01-01

    This work emphasizes the advantages about the use of structured packing. This type of packings allows by its geometry to reduce the processing time giving energy savings and throw down the production costs in several industries such as heavy water production plants, petrochemical industry and all industries involved with separation processes. There is a comparative results of energy consumption utilizing the structured vs. Raschig packings. (Author)

  18. Does energy labelling on residential housing cause energy savings?

    Energy Technology Data Exchange (ETDEWEB)

    Kjaerbye, V.H.

    2009-07-01

    Danish households use more than 30% of the total amount of energy being used in Denmark. More than 80% of this energy is dedicated to space heating. The same relation is seen in many OECD countries. The corresponding energy savings potential was recently estimated at 30% of the energy used in buildings. Energy labelling is seen as an important instrument to target these potential energy savings. This paper evaluates the effects of the Danish Energy Labelling Scheme on energy consumption in existing single-family houses with propensity score matching using real metered natural gas consumption and a very wide range of register data describing the houses and households. The study did not find significant energy savings due to the Danish Energy Labelling Scheme, but more research would be needed to complement this conclusion

  19. A Study of Energy Saving Shoes for Walking Robot

    Science.gov (United States)

    Minakata, Hideaki; Tadakuma, Susumu

    In this paper, we propose flexible shoe system to apply passive walking manner to ordinary humanoid biped. In this system, 2DOF (FF & FB) control scheme is used and realize walking with less ankle torque. The effectiveness is confirmed by computer simulation and experimental result, so we call this system as “energy saving shoes".

  20. Mission aware energy saving strategies for Army ground vehicles

    Science.gov (United States)

    Dattathreya, Macam S.

    Fuel energy is a basic necessity for this planet and the modern technology to perform many activities on earth. On the other hand, quadrupled automotive vehicle usage by the commercial industry and military has increased fuel consumption. Military readiness of Army ground vehicles is very important for a country to protect its people and resources. Fuel energy is a major requirement for Army ground vehicles. According to a report, a department of defense has spent nearly $13.6 billion on fuel and electricity to conduct ground missions. On the contrary, energy availability on this plant is slowly decreasing. Therefore, saving energy in Army ground vehicles is very important. Army ground vehicles are embedded with numerous electronic systems to conduct missions such as silent and normal stationary surveillance missions. Increasing electrical energy consumption of these systems is influencing higher fuel consumption of the vehicle. To save energy, the vehicles can use any of the existing techniques, but they require complex, expensive, and time consuming implementations. Therefore, cheaper and simpler approaches are required. In addition, the solutions have to save energy according to mission needs and also overcome size and weight constraints of the vehicle. Existing research in the current literature do not have any mission aware approaches to save energy. This dissertation research proposes mission aware online energy saving strategies for stationary Army ground vehicles to save energy as well as to meet the electrical needs of the vehicle during surveillance missions. The research also proposes theoretical models of surveillance missions, fuzzy logic models of engine and alternator efficiency data, and fuzzy logic algorithms. Based on these models, two energy saving strategies are proposed for silent and normal surveillance type of missions. During silent mission, the engine is on and batteries power the systems. During normal surveillance mission, the engine is

  1. Does nuclear energy save global environment?

    International Nuclear Information System (INIS)

    Matsui, Kazuaki

    2006-01-01

    Since the ecological footprint analysis in 1970s suggested changing consumption patterns and overpopulation concerns, energy policy such as energy conservation and use of renewable energy has become of prime importance. Several results of the long-term energy demand and supply analysis in 2050 or 2100 to reduce drastically carbon dioxide emission as a measure against global warming, showed the necessity of nuclear power deployment as well as maximum efforts to save energy, exploitation of the separation and disposal of carbon dioxide, and shifting energy sources to fuels that emit less greenhouse gases or non-fossil fuels. As a promising means to contribute to long-term energy supply, nuclear power generation is expected with improving safety, economic efficiency, environmental adaptability, and nuclear proliferation resistance of the technologies. (T.Tanaka)

  2. Energy Savings Potential of Radiative Cooling Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Alvine, Kyle J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-30

    Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), conducted a study to estimate, through simulation, the potential cooling energy savings that could be achieved through novel approaches to capturing free radiative cooling in buildings, particularly photonic ‘selective emittance’ materials. This report documents the results of that study.

  3. Save Energy Now Assessments Results 2008 Detailed Report

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Anthony L [ORNL; Martin, Michaela A [ORNL; Nimbalkar, Sachin U [ORNL; Quinn, James [U.S. Department of Energy; Glatt, Ms. Sandy [DOE Industrial Technologies Program; Orthwein, Mr. Bill [U.S. Department of Energy

    2010-09-01

    In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to

  4. Energy saving and energy efficiency concepts for policy making

    NARCIS (Netherlands)

    Oikonomou, V.; Becchis, F.; Steg, L.; Russolillo, D.

    2009-01-01

    Departing from the concept of rational use of energy, the paper outlines the microeconomics of end-use energy saving as a result of frugality or efficiency measures. Frugality refers to the behaviour that is aimed at energy conservation, and with efficiency we refer to the technical ratio between

  5. How to prevent greenhouse gas emissions in electrical installations: lighting energy savings and solar energy approaches

    International Nuclear Information System (INIS)

    Yavuz, C.; Aksoy, C.

    2012-01-01

    Day by day greenhouse gas emissions increase dramatically. A passive adaptive method of lighting energy savings, daylight responsive systems are considered one of the best solutions for energy efficiency, saving and prevent CO 2 emissions. Results of an annual experiment which was held in Sakarya University proves the necessity of daylight responsive systems with a 41% energy saving and 942.5 kg of prevented CO 2 emissions Thinking this prevention is realized just only in a 36 m 2 room with the use of 8 luminaries spreading such systems to nationwide, a major amount of greenhouse gas emissions would be prohibited. On the other hand energy saving is not the only way to reduce CO 2 emissions. Again in Sakarya University a project has started to investigate the possibility of illumination of a complete building by using solar energy. This paper evaluates these mentioned systems both in energy efficiency, greenhouse gas emissions prevention and economic point of views. (author)

  6. Incorporating Non-energy Benefits into Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Peter; Goldman, Charles; Gilligan, Donald; Singer, Terry

    2012-06-01

    This paper evaluates the issue of non-energy benefits within the context of the U.S. energy services company (ESCO) industry?a growing industry comprised of companies that provide energy savings and other benefits to customers through the use of performance-based contracting. Recent analysis has found that ESCO projects in the public/institutional sector, especially at K-12 schools, are using performance-based contracting, at the behest of the customers, to partially -- but not fully -- offset substantial accumulated deferred maintenance needs (e.g., asbestos removal, wiring) and measures that have very long paybacks (roof replacement). This trend is affecting the traditional economic measures policymakers use to evaluate success on a benefit to cost basis. Moreover, the value of non-energy benefits which can offset some or all of the cost of the non-energy measures -- including operations and maintenance (O&M) savings, avoided capital costs, and tradable pollution emissions allowances-- are not always incorporated into a formal cost-effectiveness analysis of ESCO projects. Nonenergy benefits are clearly important to customers, but state and federal laws that govern the acceptance of these types of benefits for ESCO projects vary widely (i.e., 0-100percent of allowable savings can come from one or more non-energy categories). Clear and consistent guidance on what types of savings are recognized in Energy Savings agreements under performance contracts is necessary, particularly where customers are searching for deep energy efficiency gains in the building sector.

  7. Economic and Environmental Impact of Energy Saving in Healthcare Buildings

    Directory of Open Access Journals (Sweden)

    Justo García-Sanz-Calcedo

    2018-03-01

    Full Text Available The purpose of this article is to estimate the economic and environmental impacts of energy consumption derived from healthcare buildings and proposes several energy-saving options in the sector. An experimental energy consumption study was development between 2005 and 2013 in 12 hospitals and 70 healthcare centres in Spain, built between 1980 and 2005 through audits carried out between 2005 and 2012, performed by the Extremadura Energy Agency. The study focused on electric energy, HVAC, DWH, lighting systems, renewable energies, maintenance strategy, thermal insulation, and optimal building size. Specifically, the following parameters were evaluated: energy savings, investment emission of CO2, NO2, and SO2 gases, and payback. The results revealed that through an appropriate energy management of healthcare buildings it is possible to save up to 8.60 kWh/m2 per year, for buildings of less than 5000 m2 (with no beds, which represents an expense of 1.55 €/m2. In healthcare buildings larger than 5000 m2 (with beds, it was possible to save up to 6.88 kWh/m2 per year, which represents an expense of 1.25 €/m2.

  8. Good practice in saving energy at school

    Science.gov (United States)

    Veronesi, Paola; Bonazzi, Enrico

    2014-05-01

    We teach students between 14 and 18 years old at a high school in Italy. In the first class, one of the topics we treat is related to the atmosphere. The students learn the composition of air, the importance of the natural greenhouse effect in keeping the average temperature of the planet and how human activity is increasing the level of greenhouse gases, enhancing greenhouse effect and causing global warming. It is possible to reach this knowledge using different materials and methods such as schoolbooks, articles, websites or films, individual or group work, but as students gradually become aware of the problem of climate change due to global warming, it is necessary to propose a solution that can be experienced and measured by students. This is the aim of the project "Switch off the light, to switch on the future". The project doesn't need special materials to be carried out but all the people in the community who work and "live" at school should participate in it. The project deals directly with saving electric energy, by changing the habits of the use of electricity. Saving electric energy means saving CO2 emitted to atmosphere, and consequently contributing to the reduction of greenhouse gases emission. Normally, lights in the school are switched on in the early morning and switched off at the end of lessons. Nobody is responsible to turn out the lights in classes, so students choose one or two "Light guardians" who are responsible for the light management. Simple rules for light management are written and distributed in the classes so that the action of saving energy is spread all over the school. One class participates in the daily data collection from the electricity meter, before and after the beginning of the action. At the end of the year the data are treated and presented to the community, verifying if the electric consumption has been cut down or not. This presentation is public, with students who directly introduce collected data, results and

  9. Making the results of bottom-up energy savings comparable

    Directory of Open Access Journals (Sweden)

    Moser Simon

    2012-01-01

    Full Text Available The Energy Service Directive (ESD has pushed forward the issue of energy savings calculations without clarifying the methodological basis. Savings achieved in the Member States are calculated with rather non-transparent and hardly comparable Bottom-up (BU methods. This paper develops the idea of parallel evaluation tracks separating the Member States’ issue of ESD verification and comparable savings calculations. Comparability is ensured by developing a standardised BU calculation kernel for different energy efficiency improvement (EEI actions which simultaneously depicts the different calculation options in a structured way (e.g. baseline definition, system boundaries, double counting. Due to the heterogeneity of BU calculations the approach requires a central database where Member States feed in input data on BU actions according to a predefined structure. The paper demonstrates the proposed approach including a concrete example of application.

  10. Energy-saving lamps - the hit in horticulture

    Energy Technology Data Exchange (ETDEWEB)

    Domke, O.

    1984-01-01

    In lighting chains, it is not possible to exchange energy saving lamps for light bulbs (market gardening). In the shop sector, however, there will be a number of useful purposes for them (important: long life). Energy-saving lamps function like fluorescent lamps. They can be exchanged for ordinary bulbs because they have the same screw-in system. Economy lamps and fluorescent tubes use approximately 75% less electricity than comparable bulbs, and at the same time, they last about five times as long. What sort of lamp is used should be carefully considered according to what it is to be used for. (orig.).

  11. Modelling of electricity savings in the Danish households sector: from the energy system to the end-user

    DEFF Research Database (Denmark)

    Baldini, Mattia; Trivella, Alessio

    2017-01-01

    In this paper, we examine the value of investing in energy-efficient household appliances from both an energy system and end-user perspectives. We consider a set of appliance categories constituting the majority of the electricity consumption in the private household sector, and focus on the stock...... of products which need to be replaced. First, we look at the energy system and investigate whether investing in improved energy efficiency can compete with the cost of electricity supply from existing or new power plants. To assess the analysis, Balmorel, a linear optimization model for the heat and power...... sectors, has been extended in order to endogenously determine the best possible investments in more efficient home appliances. Second, we propose a method to relate the optimal energy system solution to the end-user choices by incorporating consumer behaviour and electricity price addition due to taxes...

  12. A hybrid method of incorporating extended priority list into equal incremental principle for energy-saving generation dispatch of thermal power systems

    International Nuclear Information System (INIS)

    Cheng, Chuntian; Li, Shushan; Li, Gang

    2014-01-01

    The energy-saving generation dispatch (ESGD) policy released by Chinese Government in 2007 is a new code for optimally dispatching electric power generation portfolio in the country with the dual objectives of improving energy efficiency and reducing environmental pollution. The ESGD is substantially different from the competitive market in the developed economies, the traditional economic dispatching or the rational dispatching principle implemented in China prior to the new policy. This paper develops a hybrid method that integrates the extended priority list (EPL), the equal incremental principle (EIP) and a heuristic method to optimize daily generation schedules under ESGD. The EPL is presented to search desirable units set that satisfies the complicated duration period requirements based on thermal unit generation priority list. The EIP is developed to allocate load among the committed units within the combined set. A heuristic method is proposed to deal with inequality constraints, which usually result in difficulty for power allocation, and used to improve these results. The algorithm has been embedded into a newly developed decision support system that is currently being used by operators of the Guizhou Province Power Grid to make day-ahead quarter-hourly generation schedules. - Highlights: • Electric power industry is one of key and important fields for energy conservation and emission reduction in China. • The energy-saving generation dispatch policy was released by Chinese government in 2007. • A Hybrid algorithm for energy-saving generation dispatch scheduling of thermal power system is presented. • The algorithm has been embedded into a newly developed decision support system

  13. 48 CFR 23.205 - Energy-savings performance contracts.

    Science.gov (United States)

    2010-10-01

    ... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Energy and Water Efficiency and Renewable Energy 23.205 Energy-savings... the National Energy Conservation Policy Act (42 U.S.C. 8287) to use an energy-savings performance...

  14. Decentralized energy-saving hydraulic concepts for mobile working machines

    OpenAIRE

    Lodewyks, Johann; Zurbrügg, Pascal

    2016-01-01

    The high price of batteries in working machines with electric drives offer a potential for investment in energy-saving hydraulic systems. The decentralized power network opens up new approaches for hydraulic- and hybrid circuits. In addition, the regeneration of energy can be used at any point of the machine. For the example of an excavator arm drive with a double cylinder two compact hydraulic circuits are presented, which relieve a central hydraulic system.

  15. How to estimate realistic energy savings in Energy Performance Certificates

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Altmann, Nagmeh; Berecová, Monika

    to suggested building energy upgrading in the EPC will also deviate from the actual achieved energy savings. Adjusting input boundary condition to the actual values, will often result in realistic (comparable with measured energy consumption) calculated energy demands. This even happens in simple, quasi...... renovation. In this context, it is important to distinguish between benchmarking/certification and calculation of expected energy demand based on realistic input data.......Given the fact that most MS use fixed or other kinds of default values as boundary condition input for energy performance calculations, it is not surprising that the calculated energy performance differs from the measured energy consumption. As a consequence, the calculated energy savings due...

  16. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in the Hot-Dry and Mixed-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Davis Energy Group (DEG); Florida Solar Energy Center (FSEC); IBACOS; National Association of Home Builders Research Center (NAHBRC); National Renewable Energy Laboratory (NREL)

    2006-01-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Hot-Dry/Mixed-Dry Climate Region on a cost neutral basis.

  17. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Mixed-Humid Climates; January 2006 - December 2006

    Energy Technology Data Exchange (ETDEWEB)

    Building America Industrialized Housing Partnership (BAIHP); Building Industry Research Alliance (BIRA); Building Science Consortium (BSC); Consortium for Advanced Residential Buildings (CARB); Davis Energy Group (DEG); IBACOS; National Association of Home Builders Research Center (NAHBRC); National Renewable Energy Laboratory (NREL)

    2006-12-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.

  18. The EU must triple its energy saving policy effect

    NARCIS (Netherlands)

    Wesselink, B.; Eichhammer, W.; Harmsen, R.

    2010-01-01

    The impact of EU energy savings policy must triple to achieve the bloc’s 2020 energy savings goal. But such efforts could get a much better foundation if European leaders set a binding energy consumption target, rather than the current indicative savings target. The evidence for such

  19. THEORETICAL ASPECTS OF BASIC PROVISIONS OF THE ENERGY SAVING MANAGEMENT SYSTEM IN THE FIELD OF HOUSING AND PUBLIC UTILITIES THROUGH INTRODUCTION OF SMALL INNOVATIVE ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Kiseleva Ekaterina Alexandrovna

    2012-10-01

    Full Text Available The author addresses solutions to problems of the housing and utilities sector (including a substantial depreciation of fixed assets of the municipal infrastructure, a gap between domestic utilities management technologies and those employed worldwide, and the fund raising problem through power saving actions to be facilitated by small innovative enterprises. The proposed solutions contribute to formation of new jobs in the regions, reduction of power consumption and higher efficiency of regional economies due to reduced costs and rates (prices set for utilities-related services, and improvement of the standard and quality of living. The principal objective is to develop a set of procedures and criteria to serve as the basis for the selection of tools of power saving innovations in the housing and utilities sector of regions and municipalities. The above actions are to be implemented through the involvement of small innovative enterprises. The basic tools (instruments of the state social and economic (including innovation-related policy, that are to stimulate subjects of innovative activities to implement innovative projects in this sector stimulate energy efficiency innovations in the housing and utilities sector. The proposed set of tools includes tax holidays, subsidies, grants, soft loans, concessional loans, state and municipal orders, etc. The procedure of selection of instruments of state-initiated innovations designated for the improvement of the power efficiency of the housing and public utilities sector to be implemented by regional and municipal authorities is proposed by the author. The author identifies several types of energy saving innovations in the housing and utilities sector, based on their systemic effects. Upon identification of the top-priority recipients of state support, financial resources are to be distributed. Advantages of innovative energy saving projects in the housing and utilities sector, developed and implemented

  20. The energy-saving effects of ground-coupled heat pump system integrated with borehole free cooling: A study in China

    International Nuclear Information System (INIS)

    Zhou, Zhihua; Wu, Shengwei; Du, Tao; Chen, Guanyi; Zhang, Zhiming; Zuo, Jian; He, Qing

    2016-01-01

    Highlights: • Investigate the suitable application scope of free cooling system. • Simulate and predict its COP and carbon reduction. • Compare the temperature changes of underground soil between free cooling mode and conventional cooling mode. • Suggest the use of free cooling. - Abstract: Ground coupled heat pump (GCHP) systems have been widely implemented due to its potential benefits of energy savings. However, very few studies attempted to examine the operational performance of GCHP system integrated with borehole free cooling (i.e. using the circulating water in ground heat exchanger for the cooling purpose). A typical office building in Tianjin was chosen for a detailed case study. Both experiments and numerical simulation are employed to examine the efficiency of proposed GCHP system by means of comparing the normal running mode (NRM) and the energy-saving running mode (ESRM) in terms of the energy consumption and soil temperature variation. The results showed that the energy efficiency ratio (EER system ) of the system increased every year in winter but decreased gradually in summer during 10 years of operation. In winter, the EER system of NRM was 3.4% higher than that of ESRM. In summer, the EER system of NRM was 0.5% lower than that of ESRM under the same normal cooling mode (NM c ). The EER system of free cooling mode (FM c ) could reach as high as 23.35, which was 5.2 times higher than that of NM c . In summer, the EER system of ESRM was 13.58 on average, which was 2.6 times higher than that of NRM. The soil temperature gained minor rise under both modes during 10 years’ operation. This study revealed that there are significant energy savings benefits if the GCHP system is integrated with FM c . Meanwhile, the requirements related to temperature and humidity can be satisfied when the indoor thermal and moisture load are not too high. Therefore, the integration of FM c with GCHP system could be considered for the operation of office buildings

  1. Government control or low carbon lifestyle? – Analysis and application of a novel selective-constrained energy-saving and emission-reduction dynamic evolution system

    International Nuclear Information System (INIS)

    Fang, Guochang; Tian, Lixin; Fu, Min; Sun, Mei

    2014-01-01

    This paper explores a novel selective-constrained energy-saving and emission-reduction (ESER) dynamic evolution system, analyzing the impact of cost of conserved energy (CCE), government control, low carbon lifestyle and investment in new technology of ESER on energy intensity and economic growth. Based on artificial neural network, the quantitative coefficients of the actual system are identified. Taking the real situation in China for instance, an empirical study is undertaken by adjusting the parameters of the actual system. The dynamic evolution behavior of energy intensity and economic growth in reality are observed, with the results in perfect agreement with actual situation. The research shows that the introduction of CCE into ESER system will have certain restrictive effect on energy intensity in the earlier period. However, with the further development of the actual system, carbon emissions could be better controlled and energy intensity would decline. In the long run, the impacts of CCE on economic growth are positive. Government control and low carbon lifestyle play a decisive role in controlling ESER system and declining energy intensity. But the influence of government control on economic growth should be considered at the same time and the controlling effect of low carbon lifestyle on energy intensity should be strengthened gradually, while the investment in new technology of ESER can be neglected. Two different cases of ESER are proposed after a comprehensive analysis. The relations between variables and constraint conditions in the ESER system are harmonized remarkably. A better solution to carry out ESER is put forward at last, with numerical simulations being carried out to demonstrate the results. - Highlights: • Use of nonlinear dynamical method to model the selective-constrained ESER system. • Monotonic evolution curves of energy intensity and economic growth are obtained. • Detailed analysis of the game between government control and low

  2. Energy saving and energy efficiency concepts for policy making

    Energy Technology Data Exchange (ETDEWEB)

    Oikonomou, V. [SOM, University of Groningen, PO Box 800, 9700 AV Groningen (Netherlands); Becchis, F. [POLIS Department, University of East Piedmont, via Duomo, 6-13100 Vercelli (Italy); Steg, L. [Faculty of Behavioural and Social Sciences, University of Groningen, P.O. Box 72 9700 AB (Netherlands); Russolillo, D. [Fondazione per l' Ambiente ' T. Fenoglio' , Via Gaudenzio Ferrari 1, I-10124 Torino (Italy)

    2009-11-15

    Departing from the concept of rational use of energy, the paper outlines the microeconomics of end-use energy saving as a result of frugality or efficiency measures. Frugality refers to the behaviour that is aimed at energy conservation, and with efficiency we refer to the technical ratio between energy input and output services that can be modified with technical improvements (e.g. technology substitution). Changing behaviour from one side and technology from the other are key issues for public energy policy. In this paper, we attempt to identify the effects of parameters that determine energy saving behaviour with the use of the microeconomic theory. The role of these parameters is crucial and can determine the outcome of energy efficiency policies; therefore policymakers should properly address them when designing policies. (author)

  3. Energy saving and energy efficiency concepts for policy making

    International Nuclear Information System (INIS)

    Oikonomou, V.; Becchis, F.; Steg, L.; Russolillo, D.

    2009-01-01

    Departing from the concept of rational use of energy, the paper outlines the microeconomics of end-use energy saving as a result of frugality or efficiency measures. Frugality refers to the behaviour that is aimed at energy conservation, and with efficiency we refer to the technical ratio between energy input and output services that can be modified with technical improvements (e.g. technology substitution). Changing behaviour from one side and technology from the other are key issues for public energy policy. In this paper, we attempt to identify the effects of parameters that determine energy saving behaviour with the use of the microeconomic theory. The role of these parameters is crucial and can determine the outcome of energy efficiency policies; therefore policymakers should properly address them when designing policies.

  4. Estimating the energy saving potential of telecom operators in China

    International Nuclear Information System (INIS)

    Yang, Tian-Jian; Zhang, Yue-Jun; Huang, Jin; Peng, Ruo-Hong

    2013-01-01

    A set of models are employed to estimate the potential of total energy saved of productions and segmented energy saving for telecom operators in China. During the estimation, the total energy saving is divided into that by technology and management, which are derived from technical reform and progress, and management control measures and even marketing respectively, and the estimating methodologies for energy saving potential of each segment are elaborated. Empirical results from China Mobile indicate that, first, the technical advance in communications technology accounts for the largest proportion (70%–80%) of the total energy saved of productions in telecom sector of China. Second, technical reform brings about 20%–30% of the total energy saving. Third, the proportions of energy saving brought by marketing and control measures appear relatively smaller, just less than 3%. Therefore, China's telecom operators should seize the opportunity of the revolution of communications network techniques in recent years to create an advanced network with lower energy consumption

  5. Breakthrough Energy Savings with Waterjet Technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee W. Saperstein; R. Larry Grayson; David A. Summers; Jorge Garcia-Joo; Greg Sutton; Mike Woodward; T.P. McNulty

    2007-05-15

    Experiments performed at the University of Missouri-Rolla's Waterjet Laboratory have demonstrated clearly the ability of waterjets to disaggregate, in a single step, four different mineral ores, including ores containing iron, lead and copper products. The study focused mainly on galena-bearing dolomite, a lead ore, and compared the new technology with that of traditional mining and milling to liberate the valuable constituent for the more voluminous host rock. The technical term for the disintegration of the ore to achieve this liberation is comminution. The potential for energy savings if this process can be improved, is immense. Further, if this separation can be made at the mining face, then the potential energy savings include avoidance of transportation (haulage and hoisting) costs to move, process and store this waste at the surface. The waste can, instead, be disposed into the available cavities within the mine. The savings also include the elimination of the comminution, crushing and grinding, stages in the processing plant. Future prototype developments are intended to determine if high-pressure waterjet mining and processing can be optimized to become cheaper than traditional fragmentation by drilling and blasting and to optimize the separation process. The basic new mining process was illustrated in tests on two local rock types, a low-strength sandstone with hematite inclusions, and a medium to high-strength dolomite commonly used for construction materials. Illustrative testing of liberation of minerals, utilized a lead-bearing dolomite, and included a parametric study of the optimal conditions needed to create a size distribution considered best for separation. The target goal was to have 50 percent of the mined material finer than 100 mesh (149 microns). Of the 21 tests that were run, five clearly achieved the target. The samples were obtained as run-of-mine lumps of ore, which exhibited a great deal of heterogeneity within the samples. This

  6. Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.; Zhang, Jian; Cohan, David F.

    2016-08-22

    An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

  7. Potential opportunities for energy savings in a Jordanian poultry company

    International Nuclear Information System (INIS)

    AlQdah, K.

    2010-01-01

    Rising concern about energy resource availability and energy prices in Jordan, cost of energy has become an issue that cannot be ignored in Jordan's industrial sector. In this study, energy auditing in a meat production factory related to poultry company was carried out. Based on the collected data and the conservation laws of energy, the performance of steam boilers, domestic hot water boilers, compressors, refrigeration systems, chillers, pumps, daily consumption of diesel and water were reviewed. The percentage of energy consumed by the refrigeration units, with respect to the total energy consumed, has been estimated. The results demonstrated a normal operation with thermal efficiency of 80.66% for the steam boiler, ability to save 18818.99 JD by installing economizer with payback period of 0.637 year and a 12.3% reduction of the energy cost achieved by reducing the blow down rate. The rate of diesel consumption was reduced by 12.87% over the last period of the study as a result of the recommendations that have been submitted to the technicians and professionals. The sum of 22223.77 JD can be saved by using heavy fuel oil instead of diesel oil. Moreover, this study demonstrated that energy saving can be considered as an ideal choice to increase profit and promote competition within the poultry industry if the company adopts all the proposals and recommendations that have been offered by this study.

  8. Energy aspects and potential energy savings of the new DASI process for milk sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Frey, B.C. (Univ. of Maryland, College Park); Stewart, L.E.; Chandarana, D.; Wolfson, R.P.

    1981-01-01

    An experimental study was conducted to determine the difference in total processing energy required by the DASI ultra-high temperature (UHT) system and a conventional high temperature short time (HTST) fluid milk system. Data available in the literature were used to develop an energy use profile for the current US fluid milk system from processor to consumer. The energy data measured and the profile developed were used to estimate the potential energy savings resulting from the introduction of sterile milk in the US fluid milk market. Savings of energy resulting from the introduction of sterile milk were estimated to be 12 million barrels of oil annually.

  9. Compressed Air System Optimization Saves Energy and Improves Production at a Textile Manufacturing Mill (Peerless Division, Thomaston Mills, Inc.): Office of Industrial Technologies (OIT) BestPractices Technical Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Wogsland, J.

    2001-06-18

    This case study is one in a series on industrial firms who are implementing energy efficient technologies and system improvements into their manufacturing processes. This case study documents the activities, savings, and lessons learned on the textile manufacturing mill project.

  10. An Environmental Analysis of the Effect of Energy Saving, Production and Recovery Measures on Water Supply Systems under Scarcity Conditions

    Directory of Open Access Journals (Sweden)

    Valeria Puleo

    2015-06-01

    Full Text Available Water is one of the primary resources provided for maintaining quality of life and social status in urban areas. As potable water is considered to be a primary need, water service has usually been managed without examining the economic and environmental sustainability of supply processes. Currently, due to increases in energy costs and the growth of environment preservation policies, reducing water leakage, energy consumption and greenhouse gas (GHG production have become primary objectives in reducing the environmental footprint of water service. The present paper suggests the implementation of some performance indicators that show the interdependence of water loss, energy consumption and GHG emission. These indicators are used to compare a few possible mitigation scenarios involving water loss reduction and increasing the system’s energy efficiency. The proposed indicators were applied to a complex urban water supply system serving the city of Palermo (Italy.

  11. Food and drink processing: Introducing energy saving opportunities for business

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-04-15

    The food and drink processing industry is the fourth highest industrial energy user in the UK. In 2000, it consumed nearly 70TWh (enough energy to power one million homes for nearly 15 years) and emitted around 13 million tonnes of carbon dioxide into the atmosphere. Energy consumption in the sector could be considerably reduced by implementing simple and effective energy saving measures, reducing carbon emissions and cutting the costs for businesses. This publication is aimed at managers in the industry working in all sub-sectors. Focusing on the low and no-cost measures and actions which will have the quickest payback, this overview demonstrates the best energy saving opportunities in the sector. The industry is very diverse with many sub-sectors. Each sub-sector employs a range of industrial processes. This guide concentrates on technologies and management techniques that offer the greatest potential for energy saving and that are common to the widest range of sub-sectors. These are: Refrigeration; Process measurement and control; Compressed air; Motors and drives; Boilers and heat distribution; Cooking; Distillation, drying and evaporation; Energy management. The relative importance of each area will also depend on the sub-sector. For example, refrigeration cost will make up a large proportion of energy bills in the frozen and chilled foods sub-sector. Equally, for a business that produces confectionery, boilers and heat distribution systems will make the largest contribution. (GB)

  12. An air-conditioning, ventilation and automatic ventilation monitoring and recording system constructed in an unsealed radioisotope laboratory. Energy-saving measures in Nagasaki University Radioisotope Center

    International Nuclear Information System (INIS)

    Takatsuji, Toshihiro; Yoshida, Masahiro; Takao, Hideaki; Okumura, Yutaka; Ooura, Tosinobu; Kotoura, Kazuki; Yamanaka, Yasushi; Yanagita, Hiroyoshi.

    1998-01-01

    We constructed an automatic operation system of air-conditioners and ventilators in a radiation controlled area to minimize electric consumption. The system operates the air-conditioner and the ventilator of each ventilation unit when someone is staying in rooms belonging to the unit based on information from an access control system to the controlled area and lighting switches in front of individual room. For understanding of operation conditions and confirmation of radioactive concentration in air lower than the legal limit at the ventilation stack, we also constructed an automatic ventilation monitoring and recording system, which makes complete operation records of each ventilator automatically. These systems enabled to achieve sharp energy-saving compatible with radiation protection. (author)

  13. Building America Residential System Research Results. Achieving 30% Whole House Energy Savings Level in Hot-Dry and Mixed-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hendron, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Eastment, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jalalzadeh-Azar, A. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2006-01-01

    This report summarizes Building America research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Hot-Dry/Mixed-Dry Climate Region on a cost-neutral basis.

  14. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Mixed-Humid Climates; January 2006 - December 2006

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hendron, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Eastment, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jalalzadeh-Azar, A. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2006-12-01

    This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.

  15. Energy Savings Potential and Research & Development Opportunities for Commercial Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2009-09-01

    This study documents the energy consumption of commercial refrigeration equipment (CRE) in the U.S. and evaluated the energy savings potential of various technologies and energy efficiency measures that could be applied to such equipment. The study provided an overview of CRE applications, assessed the energy-savings potential of CRE in the U.S., outline key barriers to adoption of energy-savings technologies, and recommended opportunities for advanced energy saving technology research. The study was modeled after an earlier 1996 report by Arthur D. Little, Inc., and updated key information, examined more equipment types, and outlined long-term research and development opportunities.

  16. COMPUTER MODELLING OF ENERGY SAVING EFFECTS

    Directory of Open Access Journals (Sweden)

    Marian JANCZAREK

    2016-09-01

    Full Text Available The paper presents the analysis of the dynamics of the heat transfer through the outer wall of the thermal technical spaces, taking into account the impact of the sinusoidal nature of the changes in atmospheric temperature. These temporal variations of the input on the outer surface of the chamber divider result at the output of the sinusoidal change on the inner wall of the room, but suitably suppressed and shifted in phase. Properly selected phase shift is clearly important for saving energy used for the operation associated with the maintenance of a specific regime of heat inside the thermal technical chamber support. Laboratory tests of the model and the actual object allowed for optimal design of the chamber due to the structure of the partition as well as due to the orientation of the geographical location of the chamber.

  17. Energy-Saving in Brew-Rectification

    Directory of Open Access Journals (Sweden)

    N. I. Ulyanau

    2008-01-01

    Full Text Available The paper investigates dynamics of rectification process on one plate of a column. The basic channels controlling brew-rectification process are described in the paper.The paper also considers problems pertaining to synthesis of an adaptive system that controls non-stationary objects with delay. Synthesis of adaptive systems that automatically control product quality and saving on power resources and productivity with the help of the second method of Lyapunov has been carried out in the paper.Industrial introduction of the given automatic control system of technological process shall permit to increase productivity of a rectification (10–15 %, to decrease specific power consumption by (5–10 % while preserving the specified quality of rectified ethyl alcohol and decrease alcohol losses with luting water and malt-residue.

  18. Energy conservation, energy efficiency and energy savings regulatory hypotheses - taxation, subsidies and underlying economics

    Energy Technology Data Exchange (ETDEWEB)

    Trumpy, T. [International Legal Counsel, Brussels (Belgium)

    1995-12-01

    More efficient use of energy resources can be promoted by various regulatory means, i.e., taxation, subsidies, and pricing. Various incentives can be provided by income and revenue tax breaks-deductible energy audit fees, energy saving investment credits, breaks for energy saving entrepreneurs, and energy savings accounts run through utility accounts. Value added and excise taxes can also be adjusted to reward energy saving investments and energy saving entrepreneurial activity. Incentives can be provided in the form of cash refunds, including trade-in-and-scrap programs and reimbursements or subsidies on audit costs and liability insurance. Pricing incentives include lower rates for less energy use, prepayment of deposit related to peak load use, electronically dispatched multiple tariffs, savings credits based on prior peak use, and subsidized {open_quotes}leasing{close_quotes} of more efficient appliances and lights. Credits, with an emphasis on pooling small loans, and 5-year energy savings contracts are also discussed.

  19. ANALYSIS OF ENERGY SAVING AND ENERGY EFFICIENCY ISSUES DURING OPERATION OF THE METRO ROLLING STOCK

    Directory of Open Access Journals (Sweden)

    A. V. Donchenko

    2016-06-01

    Full Text Available Purpose.Nowadays a problem of significant power consumption of the rolling stock during its operation is a current issue. In connection with staged electricity rates increase further development of the rail electric transport, including metro rolling stock is impossible without a use of modern energy saving solutions and energy-efficient systems. To solve the specified problem it is necessary to carry out analysis of measures and determine prospective directions in energy saving and increase of energy efficiency on the metro rolling stock. Methodology. Using methods of scientific analysis, generalization, comparative analysis, forecasting and using results of experimental studies, the authors determined main ways for reduction of energy consumption during operation of the metro rolling stock. Energy cost analysis for metro rolling stock of the public utility (PU «Kiev Metro» was carried out. A great number of research works of native and foreign authors concerning the above mentioned problem were analyzed. Findings. Principal directions in energy saving and increase of energy efficiency of the metro rolling stock are implementation of recuperation systems, energy storage systems and energy-efficient control systems. It was determined that implementation of recuperation and energy storage systems helps to save a considerable amount of energy, consumed for traction, but it involves substantial investments. It is pointed out that in current complicated conditions of economic development of Ukraine, use of energy-efficient control systems is a perspective direction in energy saving. Main advantage of this direction is the economic effect obtaining without significant investments. Originality. For the first time was performed potential assessment for energy saving as a result of energy-efficient control systems use at type routine rolling stock operation modes on sections «Khreschatik –Teatralnaya – Khreschatik» and «Shulyavskaya

  20. Super Energy Savings Performance Contracts: Federal Energy Management Program (FEMP) Program Overview (revision)

    International Nuclear Information System (INIS)

    Pitchford, P.

    2001-01-01

    This four-page publication describes the U.S. Department of Energy's (DOE's) streamlined energy savings performance contracting, or ''Super ESPC,'' process, which is managed by DOE's Federal Energy Management Program (FEMP). Under a Super ESPC, a qualifying energy service company (ESCO) from the private sector pays for energy efficiency improvements or advanced renewable energy technologies (e.g., photovoltaic systems, wind turbines, or geothermal heat pumps, among others) for a facility of a government agency. The ESCO is then repaid over time from the agency's resulting energy cost savings. Delivery orders under these contracts specify the level of performance (energy savings) and the repayment schedule; the contract term can be up to 25 years, although many Super ESPCs are for about 10 years or less

  1. Renewable energy for Canada's northern communities - quantifying potential fuel savings

    International Nuclear Information System (INIS)

    Brothers, C.

    1998-01-01

    The probable impact of renewable energy technologies on fuel consumption in Canada's remote northern communities was discussed. These communities currently meet their electricity requirements using expensive diesel powered generators. It was noted that change to renewable energy in Canada's remote communities will only be made if the economic benefits can be clearly demonstrated. A study was conducted in Cambridge Bay, Northwest Territories, in which electrical load requirements and wind and solar resource data from the community was acquired to estimate savings in diesel fuel consumption for various renewable energy technologies. Wind was found to provide the most fuel displacement and was considered to be the most appropriate technology for these communities. A photovoltaic (PV) system of equivalent size would have significantly less impact on fuel savings in a community like Cambridge Bay, in part because a PV system would be poorly correlated on a seasonal basis with the energy requirements of the community. A wind-diesel system would be the most advantageous in terms of fuel savings due to its relatively high capacity factor, and due to the fact that is it is available year around. 4 refs., 1 tab., 4 figs

  2. Annual Energy Usage Reduction and Cost Savings of a School: End-Use Energy Analysis

    Science.gov (United States)

    Alghoul, M. A.; Bakhtyar, B.; Asim, Nilofar; Sopian, K.

    2014-01-01

    Buildings are among the largest consumers of energy. Part of the energy is wasted due to the habits of users and equipment conditions. A solution to this problem is efficient energy usage. To this end, an energy audit can be conducted to assess the energy efficiency. This study aims to analyze the energy usage of a primary school and identify the potential energy reductions and cost savings. A preliminary audit was conducted, and several energy conservation measures were proposed. The energy conservation measures, with reference to the MS1525:2007 standard, were modelled to identify the potential energy reduction and cost savings. It was found that the school's usage of electricity exceeded its need, incurring an excess expenditure of RM 2947.42. From the lighting system alone, it was found that there is a potential energy reduction of 5489.06 kWh, which gives a cost saving of RM 2282.52 via the improvement of lighting system design and its operating hours. Overall, it was found that there is a potential energy reduction and cost saving of 20.7% when the energy conservation measures are earnestly implemented. The previous energy intensity of the school was found to be 50.6 kWh/m2/year, but can theoretically be reduced to 40.19 kWh/mm2/year. PMID:25485294

  3. Annual Energy Usage Reduction and Cost Savings of a School: End-Use Energy Analysis

    Directory of Open Access Journals (Sweden)

    Aiman Roslizar

    2014-01-01

    Full Text Available Buildings are among the largest consumers of energy. Part of the energy is wasted due to the habits of users and equipment conditions. A solution to this problem is efficient energy usage. To this end, an energy audit can be conducted to assess the energy efficiency. This study aims to analyze the energy usage of a primary school and identify the potential energy reductions and cost savings. A preliminary audit was conducted, and several energy conservation measures were proposed. The energy conservation measures, with reference to the MS1525:2007 standard, were modelled to identify the potential energy reduction and cost savings. It was found that the school’s usage of electricity exceeded its need, incurring an excess expenditure of RM 2947.42. From the lighting system alone, it was found that there is a potential energy reduction of 5489.06 kWh, which gives a cost saving of RM 2282.52 via the improvement of lighting system design and its operating hours. Overall, it was found that there is a potential energy reduction and cost saving of 20.7% when the energy conservation measures are earnestly implemented. The previous energy intensity of the school was found to be 50.6 kWh/m2/year, but can theoretically be reduced to 40.19 kWh/mm2/year.

  4. Improving Energy Saving Techniques by Ambient Intelligence Scheduling

    DEFF Research Database (Denmark)

    Cristani, Matteo; Karafili, Erisa; Tomazzoli, Claudio

    2015-01-01

    Energy saving is one of the most challenging aspects of modern ambient intelligence technologies, for both domestic and business usages. In this paper we show how to combine Ambient Intelligence and Artificial Intelligence techniques to solve the problem of scheduling a set of devices under a given...... for Ambient Intelligence to a specific framework and exhibit a sample usage for a real life system, Elettra, that is in use in an industrial context....

  5. Passive annual heat storage principles in earth sheltered housing, a supplementary energy saving system in residential housing

    Energy Technology Data Exchange (ETDEWEB)

    Anselm, Akubue Jideofor [Green Architecture Department, School of Architecture and Urban Planning, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2008-07-01

    This paper looks through the many benefits of earth not only as a building element in its natural form but as a building mass, energy pack and spatial enclosure which characterized by location, unique physical terrain and climatic factors can be utilized in developing housing units that will provide the needed benefits of comfort alongside the seasons. Firstly the study identifies existing sunken earth houses in the North-west of China together with identifying the characters that formed the ideas behind the choice of going below the ground. Secondly, the study examines the pattern of heat exchange, heat gains and losses as to identify the principles that makes building in earth significant as an energy conservation system. The objective of this, is to relate the ideas of sunken earth home design with such principles as the passive annual heat storage systems (PAHS) in producing houses that will serve as units used to collect free solar heat all summer and cools passively while heating the earth around it and also keeping warm in winter by retrieving heat from the soil while utilizing the free solar heat stored throughout the summer as a year-round natural thermal resource. (author)

  6. Household preferences for energy-saving measures : A conjoint analysis

    NARCIS (Netherlands)

    Poortinga, Wouter; Steg, Linda; Vlek, Charles; Wiersma, Gerwin

    Studies on household energy use generally focus on social and psychological factors influencing the acceptability of energy-saving measures. However, the influence of physical characteristics of energy-saving measures on their acceptability is largely ignored. In this study, preferences for

  7. Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration.

    Science.gov (United States)

    Collignan, Bernard; Powaga, Emilie

    2017-11-23

    For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. ONU Power Saving Scheme for EPON System

    Science.gov (United States)

    Mukai, Hiroaki; Tano, Fumihiko; Tanaka, Masaki; Kozaki, Seiji; Yamanaka, Hideaki

    PON (Passive Optical Network) achieves FTTH (Fiber To The Home) economically, by sharing an optical fiber among plural subscribers. Recently, global climate change has been recognized as a serious near term problem. Power saving techniques for electronic devices are important. In PON system, the ONU (Optical Network Unit) power saving scheme has been studied and defined in XG-PON. In this paper, we propose an ONU power saving scheme for EPON. Then, we present an analysis of the power reduction effect and the data transmission delay caused by the ONU power saving scheme. According to the analysis, we propose an efficient provisioning method for the ONU power saving scheme which is applicable to both of XG-PON and EPON.

  9. Economic Efficiency and Investment Implementation in Energy Saving Projects

    Directory of Open Access Journals (Sweden)

    Venelin Terziev

    2017-09-01

    Full Text Available Investment in building thermoinsulation is a subject to appraisal for efficiency from the position of discounted cash flows taken specifically by energy saving. The appraisal of investment as optimal is attended by achieving the shortest term for investment implementation, the lowest investment outlays, the maximum total net value of energy savings, the shortest investment payback period. The complex application of the dynamic methods for appraising economic efficiency of an investment – net present value, internal rate of return, profitability index and discounted payback period, involves drawing of particular values which comparison definitely will show if this kind of investment is practically “attractive”. However, the question for significance weight of each of these indicators above in decision making for implementation a particular real investment still remains unsolved. This requires working out a system of criteria, priorities that can determine which of the indicators for economic efficiency of specific investment project will have the highest significance.

  10. Concept for Specific Lines of Business, Energy Saving Tourism

    International Nuclear Information System (INIS)

    Jilek, W.

    1998-01-01

    In the spirit of the objectives of the Energy Plan 1995 in order to make more efficient use of energy and thus to reduce energy requirements, to promote the use of renewable energies, and to attach maximum importance to the ecological compatibility of the energy systems, among other project the provincial government of Styria is pursuing the option of consulting small and medium-sized enterprises in a target manner. Three years after being launched, this Ecological Company Consulting scheme for various lines of business is now producing successful results, demonstrating that energy saving, business profit and ecology can go hand in hand by example of numerous pilot projects. Trade-specific concepts have been elaborated for foodstuffs, carpenters and car repair and sales firms, bakeries and hairdressers and, most recently, for tourist industry business /hotels, bars, restaurants, etc.). The province of Styria, represented by the Energy Commissioner and the department of waste management, is co-operating closely in the Ecological Company Consulting scheme with the Styrian Chamber of Commerce and the Economy Promotion Institute (Wirtschaftsfoerderungsinstitut). In several cases, other provinces, the Federal Ministry of Environmental, Youth and Family Affairs, and the Federal Chamber of Commerce have adopted the results of this co-operation, while in some cases subsidy schemes are linked to these trade-specific concepts. In the course of the scheme, the aim is to investigate energy requirements, saving potentials and questions of waste management. (author)

  11. Modelling energy savings in the Danish building sector combined with internalisation of health related externalities in a heat and power system optimisation model

    DEFF Research Database (Denmark)

    Zvingilaite, Erika

    2013-01-01

    A substantial untapped energy saving potential rests in the building sector and is expected to play an important role in achieving reduction of environmental impacts of energy. In order to utilise this potential, effective policy measures need to be adopted to remove the existing barriers and cre...

  12. Demonstration of energy savings of cool roofs

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Gartland, L.; Akbari, H. [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.; Rainer, L. [Davis Energy Group, Davis, CA (United States)

    1998-06-01

    Dark roofs raise the summertime air-conditioning demand of buildings. For highly-absorptive roofs, the difference between the surface and ambient air temperatures can be as high as 90 F, while for highly-reflective roofs with similar insulative properties, the difference is only about 20 F. For this reason, cool roofs are effective in reducing cooling energy use. Several experiments on individual residential buildings in California and Florida show that coating roofs white reduces summertime average daily air-conditioning electricity use from 2--63%. This demonstration project was carried out to address some of the practical issues regarding the implementation of reflective roofs in a few commercial buildings. The authors monitored air-conditioning electricity use, roof surface temperature, plenum, indoor, and outdoor air temperatures, and other environmental variables in three buildings in California: two medical office buildings in Gilroy and Davis and a retail store in San Jose. Coating the roofs of these buildings with a reflective coating increased the roof albedo from an average of 0.20--0.60. The roof surface temperature on hot sunny summer afternoons fell from 175 F--120 F after the coating was applied. Summertime average daily air-conditioning electricity use was reduced by 18% (6.3 kWh/1000ft{sup 2}) in the Davis building, 13% (3.6 kWh/1000ft{sup 2}) in the Gilroy building, and 2% (0.4 kWh/1000ft{sup 2}) in the San Jose store. In each building, a kiosk was installed to display information from the project in order to educate and inform the general public about the environmental and energy-saving benefits of cool roofs. They were designed to explain cool-roof coating theory and to display real-time measurements of weather conditions, roof surface temperature, and air-conditioning electricity use. 55 figs., 15 tabs.

  13. Fractional-Order Modeling and Sliding Mode Control of Energy-Saving and Emission-Reduction Dynamic Evolution System

    DEFF Research Database (Denmark)

    Huang, Sunhua; Zhou, Bin; Li, Canbing

    2018-01-01

    represent complex dynamic behaviours with chaotic and unstable states on the energy conservation, carbon emissions, economic growth, and renewable energy development, and have a great impact on the formulation of government energy policies. Furthermore, based on the fractional Lyapunov stability and robust...

  14. Solar Energy as an Alternative to Energy Saving and Pollutant Emissions Reduction

    Directory of Open Access Journals (Sweden)

    Arina Negoițescu

    2016-10-01

    Full Text Available In the paper is analyzed thermal solar systems efficiency from the point of view of energy savings and pollutant emissions concentrations exhausted during these installations operation. For this purpose were taking into account four versions of solar panel systems combined with different types of conventional heating sources, for which were simulated the operation conditions. As a result of the simulation, there were obtained the values of energy savings and pollutant emissions during the four systems operation. By analyzing these values, the combined thermal system optimum solution was selected.

  15. Energy-saving measures in multi-storage housing construction

    Directory of Open Access Journals (Sweden)

    Мария Дмитриевна Коровина

    2017-05-01

    Full Text Available In this article the main directions of energy saving in multi-storey housing construction and methods for increasing energy efficiency are considered. The main problems of implementing energy-saving measures were touched; the need for their analysis during the development of each construction project with a view to choosing the most effective complex from the energy, economic, ecological and social points of view was justified. It is noted that such an approach can become an important factor of saving energy in the sphere of housing construction and reducing the energy intensity of the entire Russian economy.

  16. Energy saving potential of energy services - experimentation on the life cycle of energy conversion equipment

    International Nuclear Information System (INIS)

    Dupont, M.

    2006-12-01

    Energy efficiency services are growing in Europe but their role is still limited. In order to evaluate the potential, we focused first of all on policy, economical and environmental mechanisms that support their development. European natural gas and electricity markets, that are now almost wholly de-regulated, are analysed and compared to their historical structure. By introducing uncertainty on energy prices, this new deal translates better the real energy costs. Energy performance contracts (EPC) limit the impact of these uncertainties on the customer energy bills by guaranteeing a financial result. As a result of the modelling of these contracts, namely operation and maintenance ones, we prove that they transfer technical and financial risks from building owners to energy service companies (ESCO) making energy saving measures easier and less expensive at the same time. These contracts are relatively widespread for heating or compressed-air processes but remain marginal for air-conditioning systems. So new methods were needed to guarantee on the long terms the efficiency of air-conditioning systems demand (1) to master the process and its performances and (2) to be able to determine precisely the energy saving potential and its realisation costs. A detailed energy audit is thus necessary for which we propose a guidance. Conclusions of audits carried out prove that energy saving potential is mainly located in equipment management and control. These optimizations are not always carried out because of a lack of contractual incentive and due to the weaknesses of audit methods. Through the involvement of an independent expert, the mandatory and regular inspection of air-conditioning systems may allow to verify and guide such practices. A three-step analysis procedure has been developed in order to maximize the inspection potential and to get higher benefits from service contracts. (author)

  17. Proceedings of V International Conference of Renewable Energy, Energy Saving and Energy Education. CIER 2007. International Workshop of Eolic Energy

    International Nuclear Information System (INIS)

    2007-05-01

    The CD-ROM presents papers submitted to the International Conference of Renewable Energy, Energy Saving and Energy Education. CIER 2007, held in Havana, Cuba, on May 22-25, 2007. The purpose of the CIER 2007 are to offer an opportunity to engineers, investigators, academic, makers and specialists in the energy topic from all over the world to exchange experiences, to share their successes and to discuss their focuses to future in the topic of the energy renewable, the energy saving, the energy efficiency and the energy education. The objective of the International Workshop of Eolic Energy is in advancing in the dialogue international on the systems in question and their applications around the world, you they analyzed the perspectives of possible programs of cooperation in this field and their use in Cuba

  18. Demonstration of Energy Savings in Commercial Buildings for Tiered Trim and Respond Method in Resetting Static Pressure for VAV Systems

    Science.gov (United States)

    2017-03-01

    Use Intensity EW Energy and Water GHG Greenhouse Gas GWh Gigawatt hours IAARNG Iowa Army National Guard IE&E Installations, Energy...demonstrate the cost effectiveness of applying the proposed method to different DoD building types using a basic life-cycle cost analysis. Demonstration... Effects of diffuser airflow minima on occupant comfort, air mixing, and building energy use (RP-1515), Sci.Technol. Built Environ. 21 1075–1090

  19. E-SMARRT: Energy Saving Melting and Revert Reduction Technology

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-11-01

    This factsheet describes the Energy-Saving Melting and Revert Reduction Technology (E-SMARRT) program developed by Advanced Technology Institute (ATI). E-SMARRT is a balanced portfolio of projects to address energy-saving opportunities in the metalcasting industry.

  20. Energy Savings Forecast of SSL in General Illumination Report Summary

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-09-30

    Summary of the DOE report Energy Savings Forecast of Solid-State Lighting in General Illumination Applications, a biannual report that models the adoption of LEDs in the U.S. general-lighting market, along with associated energy savings, based on the full potential DOE has determined to be technically feasible over time.

  1. The energy-saving anaerobic baffled reactor membrane bioreactor (EABR-MBR) system for recycling wastewater from a high-rise building.

    Science.gov (United States)

    Ratanatamskul, Chavalit; Charoenphol, Chakraphan

    2015-01-01

    A novel energy-saving anaerobic baffled reactor-membrane bioreactor (EABR-MBR) system has been developed as a compact biological treatment system for reuse of water from a high-rise building. The anaerobic baffled reactor (ABR) compartment had five baffles and served as the anaerobic degradation zone, followed by the aerobic MBR compartment. The total operating hydraulic retention time (HRT) of the EABR-MBR system was 3 hours (2 hours for ABR compartment and very short HRT of 1 hour for aerobic MBR compartment). The wastewater came from the Charoen Wisawakam building. The results showed that treated effluent quality was quite good and highly promising for water reuse purposes. The average flux of the membrane was kept at 30 l/(m2h). The EABR-MBR system could remove chemical oxygen demand, total nitrogen and total phosphorus from building wastewater by more than 90%. Moreover, it was found that phosphorus concentration was rising in the ABR compartment due to the phosphorus release phenomenon, and then the concentration decreased rapidly in the aerobic MBR compartment due to the phosphorus uptake phenomenon. This implies that phosphorus-accumulating organisms inside the EABR-MBR system are responsible for biological phosphorus removal. The research suggests that the EABR-MBR system can be a promising system for water reuse and reclamation for high-rise building application in the near future.

  2. Energy saving and use of alternative energy at Kaercher; Energiesparen und alternative Energiekonzepte bei Kaercher

    Energy Technology Data Exchange (ETDEWEB)

    Leschtar, A. [Kaercher GmbH und Co KG, Winnenden (Germany)

    2006-07-01

    Summary: In 1996 already the environmental management system of the Kaercher head office in Winnenden was certified under ISO 14001. For its environmental commitment Kaercher was awarded several prizes. The company's activities comprise 1. General environmental activities: planting vegetation on the roof, promotion of environment sound mobility forms, co-operation with the Global Nature Fund, solvent free powder coatings, water recycling, biotope maintenance, continuous environmental training for staff members. 2. Internal measures with focus on energy saving and climate protection: photovoltaic, geothermal energy, solar energy, district heat supply from wood chip-fired heating station, heat recovery, energy saving driving techniques, energy saving competition, conversion to gas building heating, heat insulation. 3. Product-related measures: Kaercher standard 'environmental sound products' and environmental checklist for the development of new equipments. Research co-operation with the Technical University Darmstadt. Numerous technical modifications of Kaercher equipment to reduce environmental impacts. (orig.)

  3. Modelling the impact of social network on energy savings

    International Nuclear Information System (INIS)

    Du, Feng; Zhang, Jiangfeng; Li, Hailong; Yan, Jinyue; Galloway, Stuart; Lo, Kwok L.

    2016-01-01

    Highlights: • Energy saving propagation along a social network is modelled. • This model consists of a time evolving weighted directed network. • Network weights and information decay are applied in savings calculation. - Abstract: It is noted that human behaviour changes can have a significant impact on energy consumption, however, qualitative study on such an impact is still very limited, and it is necessary to develop the corresponding mathematical models to describe how much energy savings can be achieved through human engagement. In this paper a mathematical model of human behavioural dynamic interactions on a social network is derived to calculate energy savings. This model consists of a weighted directed network with time evolving information on each node. Energy savings from the whole network is expressed as mathematical expectation from probability theory. This expected energy savings model includes both direct and indirect energy savings of individuals in the network. The savings model is obtained by network weights and modified by the decay of information. Expected energy savings are calculated for cases where individuals in the social network are treated as a single information source or multiple sources. This model is tested on a social network consisting of 40 people. The results show that the strength of relations between individuals is more important to information diffusion than the number of connections individuals have. The expected energy savings of optimally chosen node can be 25.32% more than randomly chosen nodes at the end of the second month for the case of single information source in the network, and 16.96% more than random nodes for the case of multiple information sources. This illustrates that the model presented in this paper can be used to determine which individuals will have the most influence on the social network, which in turn provides a useful guide to identify targeted customers in energy efficiency technology rollout

  4. Understanding usage patterns of electric kettle and energy saving potential

    International Nuclear Information System (INIS)

    Murray, D.M.; Liao, J.; Stankovic, L.; Stankovic, V.

    2016-01-01

    Highlights: • Time-of-use analysis to motivate kettle usage and consumption prediction. • Identification of households whose kettle usage and consumption is outside the norm. • Mathematical model to estimate water volume from consumed power measurements only. • Quantification of energy savings if a household uses its kettle more efficiently. • Kettle usage and demand prediction using an Adaptive Neuro Fuzzy Inference System. - Abstract: The availability of smart metering and smart appliances enables detecting and characterising appliance use in a household, quantifying energy savings through efficient appliance use and predicting appliance-specific demand from load measurements is possible. With growing electric kettle ownership and usage, lack of any efficiency labelling guidelines for the kettle, slow technological progress in improving kettle efficiency relative to other domestic appliances, and current consumer attitudes, urgent investigation into consumer kettle usage patterns is warranted. From an efficiency point of view, little can be done about the kettle, which is more efficient than other methods of heating water such as the stove top kettle. However, since a majority households use the kettle inefficiently by overfilling, in order to meet energy targets, it is imperative to quantify inefficient usage and predict demand. For the purposes of scalability, we propose tools that depend only on load measurement data for quantifying and visualising kettle usage and energy consumption, assessing energy wastage through overfilling via our proposed electric kettle model, and predicting kettle-specific demand, from which we can estimate potential energy savings in a household and across a housing stock. This is demonstrated using data from a longitudinal study across a sample of 14 UK households for a two-year period.

  5. An analysis of the energy saving investment programmes in Latvia

    Energy Technology Data Exchange (ETDEWEB)

    Blumberga, D.; Veidenbergs, I.; Kaas, I.; Blumberga, A.; Bokta, H. [Riga Technical Univ. (Latvia)

    1997-11-01

    In the energy economy of Latvia there are different investment programs of energy efficiency improvement of energy systems and their elements. Both creditors and loan users have actions limited by legislation, financial economical, environmental, psychological and other conditions. Swedish governmental Programme `Environmentally adapted energy systems in Baltic States and Eastern Europe` started 1993 and is oriented more or less to municipalities and their owner heat energy producers and users. Three years experience allow to evaluate and estimate advantages and shortages from different viewpoints. Dutch governmental PSO Programme `Energy conservation and clean production in Latvian Agrofood Industry` started in June 1996 and is oriented to industrial branch which are developing now in Latvia. Some aspects discussed more detailed in this presentation are following: influence of state energy policy and strategy on implementation of projects; sequence of implementation of projects and need for changes in arrangement year by year; transfer of know how and technology; comparison of technical, economical and environmental data of different projects; human aspects of success of implementation of projects of energy efficiency improvement. Above mentioned Programs as well as other Energy Saving Programs in Latvia energy economy (USAID, EBRD, Danish governmental etc.) have common features characterized process in countries of post-socialism and different specific issues. (au)

  6. Large Hospital 50% Energy Savings: Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Studer, D.; Parker, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document documents the technical analysis and design guidance for large hospitals to achieve whole-building energy savings of at least 50% over ANSI/ASHRAE/IESNA Standard 90.1-2004 and represents a step toward determining how to provide design guidance for aggressive energy savings targets. This report documents the modeling methods used to demonstrate that the design recommendations meet or exceed the 50% goal. EnergyPlus was used to model the predicted energy performance of the baseline and low-energy buildings to verify that 50% energy savings are achievable. Percent energy savings are based on a nominal minimally code-compliant building and whole-building, net site energy use intensity. The report defines architectural-program characteristics for typical large hospitals, thereby defining a prototype model; creates baseline energy models for each climate zone that are elaborations of the prototype models and are minimally compliant with Standard 90.1-2004; creates a list of energy design measures that can be applied to the prototype model to create low-energy models; uses industry feedback to strengthen inputs for baseline energy models and energy design measures; and simulates low-energy models for each climate zone to show that when the energy design measures are applied to the prototype model, 50% energy savings (or more) are achieved.

  7. Builder System Performance Package Targeting 30% -- 40% Savings in Space Conditioning Energy Use: Period of Performance; December 2002 to December 2003

    Energy Technology Data Exchange (ETDEWEB)

    2004-07-01

    The Consortium for Advanced Residential Building (CARB), one of the Building America teams, describes recommended best practices to achieve 30% - 40% energy savings without compromising health or safety in houses built in cold climates, hot-humid climates, and hot-dry climates.

  8. Incentives for Energy Saving and Renewable Energy in the Netherlands

    International Nuclear Information System (INIS)

    Cace, J.

    2008-01-01

    Energy saving and renewable energy are again on the Dutch political agenda. Based on the governmental energy report, market parties have developed the action plan for the realisation of national renewable energy targets. The evaluation of recently closed subsidy programmes and development of new incentives take place in close cooperation among governmental organisations and market parties. For the financing of the action plan the government has reserved the budget up to 2011. The government believes that the implementation of energy efficiency and renewable energy will strengthen the national economy and that the benefits of these measures will exceed the costs. The main obstacles related to the implementation of a large scale wind power generation are: spatial integration, permits and connection to the grid. Also, the large scale biomass plants meet problems because of the lack of clear environmental and sustainability criteria. The Dutch targets for 2020 are: increasing of energy efficiency with 20%, 20% renewable energy and decreasing of CO 2 -emissions with 30%.(author)

  9. Potential energy savings by using direct current for residential applications

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2017-01-01

    This paper presents a study of the potential energy savings by implementing dc distribution systems for residential applications. In general, it is commonly accepted that the use of dc voltage improves the efficiency of the distribution, due to a decrease in the conduction losses and an efficiency...... improvement in the power converter units. However, for residential applications, the efficiency is not always improved. A grid connected residential microgrid, with renewable energy sources (RES), energy storage systems (ESS) and local loads, is presented in this work. The microgrid has been modelled...... loads. However, for isolated microgrids, the use of dc voltage has the potential to bring a significant efficiency improvement. Nevertheless the potential for cost reduction in all scenarios is very promising....

  10. Energy savings in the Danish building stock until 2050

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper

    2014-01-01

    are energy upgraded according to the requirements stipulated in the Danish Building Regulations 2010. Furthermore, scenario analyses was made for the potential impact on the energy consumption of introducing different levels of tightening of the energy requirements for existing buildings in the Danish...... savings, due to the level of the current requirements. Higher energy savings can, though, be achieved e.g. by setting requirements for balanced mechanical ventilation with heat recovery and use of solar heating for domestic hot water.......A study has been conducted analysing the energy savings for space heating and domestic hot water in the Danish building stock due to renovation of building components at the end of their service life. The purpose of the study was to estimate the energy savings until 2050 as building components...

  11. Technical energy savings versus changes in human behaviour

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1996-01-01

    Energy savings seems to be the most environmentally benign element in an energy policy. The paper is a reflection on the work on saving energy both by improving technology and by adapting human daily behaviour. A simple model is suggested for the energy chain which converts the primary energy all...... the way into human satisfaction via energy services. Results of various analyses and field experiments show saving potentials for electricity of 50 - 80 per cents. Barriers for implementing these technical saving options are discussed. Also the necessity and potentials for changing behavioural or life...... style is discussed, including survey results which points towards a change in values towards more demand for leisure time rather than more income. Finally result from a study for a low electricity Europe is included....

  12. Biopulping: A new energy-saving technology for papermaking

    International Nuclear Information System (INIS)

    Scott, G.M.; Akhtar, M.; Lentz, M.J.; Kirk, T.K.; Swaney, R.; Shipley, D.F.

    1997-01-01

    Biopulping is defined as the treatment of wood chips with lignin-degrading fungi prior to pulping. Fungal pretreatment prior to mechanical pulping reduces electrical energy requirements during refining or increases mill throughput, improves paper strength, reduces the pitch content, reduces cooking time for sulfite pulping, and reduces the environmental impact of pulping. The recent work involved scaling up the biopulping process towards the industrial level, investigating both the engineering and economic feasibility of the technology. The authors envision the process to be done in either a chip-pile or silo-based system for which several factors need to be considered. These factors include the degree of decontamination, a hospitable environment for the fungus, and the overall process economics. Currently, treatment of the chips with low pressure steam is sufficient for decontamination. Furthermore, a simple, forced ventilation system can be used to maintain the proper temperature, humidity, and moisture content throughout the chip bed, thus promoting uniform growth of the fungus. The pilot-scale trial resulted in the successful treatment of 4 tons, of wood chips (dry weight basis) with results comparable to those on a laboratory scale. For mechanical pulping, a 2-week treatment results in approximately 30% energy savings that, considering the additional equipment and operating costs, results in an overall savings of $9 to $20/ton of pulp in a chip-pile system. The other benefits that biopulping confers improve the economics considerably A larger, 40-ton trial was also successful, with energy savings and paper properties comparable with the laboratory scale

  13. Energy Saving in Industrial Annealing Furnaces

    Directory of Open Access Journals (Sweden)

    Fatma ÇANKA KILIÇ

    2018-03-01

    Full Text Available In this study, an energy efficiency studies have been carried out in a natural gas-fired rolling mill annealing furnace of an industrial establishment. In this context, exhaust gas from the furnace has been examined in terms of waste heat potential. In the examinations that have been made in detail; waste heat potential was found as 3.630,31 kW. Technical and feasibility studies have been carried out to realize electricity production through an Organic Rankine Cycle (ORC system for evaluating the waste heat potential of the annealing furnace. It has been calculated that 1.626.378,88 kWh/year of electricity can be generated by using the exhaust gas waste heat of the annealing furnace through an ORC system to produce electric energy with a net efficiency of 16%. The financial value of this energy was determined as 436.032,18 TL/year and the simple repayment period of the investment was 8,12 years. Since the annealing period of the annealing furnace is 2800 hours/year, the investment has not been found to be feasible in terms of the feasibility studies. However, the investment suitability can be assured when the annealing furnace is operating at full capacity for 8,000 hours or more annually.

  14. Ore concentrate line efficient operation: some energy saving implications

    Energy Technology Data Exchange (ETDEWEB)

    Ihle, Christian F. [BRASS Engineering Chile S.A., Santiago (Chile)

    2009-07-01

    Among the outstanding attributes slurry pipelines must have is the need to optimize production efficiency and, in particular, minimize energy consumption. In the present paper, the energy saving implications of three different factors, namely process variable uncertainties, transport control variables and pipeline availability are referred to and exemplified using an idealized Bingham-type slurry pipeline. Present examples suggest that important energy savings can be achieved with proper designs, equipment and operations scheduling. (author)

  15. Measured energy savings from using night temperature setback

    International Nuclear Information System (INIS)

    Szydlowski, R.F.; Wrench, L.E.; O'Neill, P.J.

    1993-01-01

    The measured energy savings resulting from using night temperature setback in typical light-construction wooden office buildings was determined. Researchers installed monitoring equipment in a six-building sample of two-story wooden buildings at Fort Devens, Massachusetts. Data obtained during both single-setting and night-setback operating modes were used to develop models of each building's heat consumption as a function of the difference between inside and outside temperature. These models were used to estimate seasonal savings that could be obtained from the use of night-setback thermostat control. The measured savings in heating energy from using night temperature setback for the six Fort Devens buildings ranged from 14% to 25%; the mean savings was 19.2%. Based on an energy cost of $0.65/therm of natural gas, the estimated average cost savings of using automatic setback thermostats in these buildings is $780 per year per building

  16. Energy Savers---Tips on Saving Energy and Money at Home (Fifth Printing)

    Energy Technology Data Exchange (ETDEWEB)

    DOE Office of Building Technology, State and Community Programs

    2001-08-13

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  17. Energy Savers--Tips on Saving Energy and Money at Home (Fifth Printing)

    International Nuclear Information System (INIS)

    DOE Office of Building Technology, State and Community Programs

    2001-01-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances

  18. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Chemical Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. chemical manufacturing. The study relies on multiple sources to estimate the energy used in the production of 74 individual chemicals, representing 57% of sector-wide energy consumption. Energy savings opportunities for individual chemicals and for 15 subsectors of chemicals manufacturing are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  19. Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Petroleum Refining

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. petroleum refining. The study relies on multiple sources to estimate the energy used in nine individual process areas, representing 68% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  20. Energy Saving Evaluation of the Ventilated BIPV Walls

    Directory of Open Access Journals (Sweden)

    Yi-Pin Lin

    2011-06-01

    Full Text Available This study integrates photovoltaic (PV system, building structure, and heat flow mechanism to propose the notion of ventilated Building-Integrated Photovoltaic (BIPV walls. The energy-saving potential of the ventilated BIPV walls was investigated via engineering considerations and computational fluid dynamics (CFD simulations. The results show that the heat removal rate and indoor heat gain of the proposed ventilated BIPV walls were dominantly affected by outdoor wind velocity and airflow channel width. Correlations for predicting the heat removal rate and indoor heat gain, the reduction ratio of the indoor heat gain, CO2 reduction, and induced indoor air exchange are introduced.

  1. Energy saving certificates. Gear up for three years... and more

    International Nuclear Information System (INIS)

    Signoret, Stephane; Petitot, Pauline; Zebboudj, Idir; Kim, Caroline; Mary, Olivier; De Santis, Audrey

    2015-01-01

    As the third period of Energy Saving Certificates (EEC) enter their third period, a first article comments the evolutions of the principles and modalities of this arrangement under the influence of the directive on energy efficiency, and how the involved actors cope with these evolutions. The main differences with the previous period are presented. They concern energy providers and eligible bodies, the level of 'cumac' KWh (cumac stands for cumulated and actualised), controls and sanctions, eligible operations, and modalities. A second article describes how the arrangement has been simplified by means of a declarative system, and outlines that the control has been strengthened and may lead to heavy sanctions. The next articles comment the consequences for the building sector, notably for thermal insulation, the implications for communities (notably for the development of the use of LEDs for public lighting and for heat networks), for the transport sector (fuel dealers, good transport optimisation programs, fossil energy saving in logistic and mobility programs), and for the agriculture sector. Some key figures related to the second period (January 2011 - December 2014) are given: number of supplied cumac KWh, distribution of EECs among sectors, evolution of the weighted monthly average price of EECs

  2. Tradable certificates for renewable electricity and energy savings

    International Nuclear Information System (INIS)

    Bertoldi, Paolo; Huld, Thomas

    2006-01-01

    Tradable green certificates (TGCs) schemes have been developed and tested in several European countries to foster market-driven penetration of renewables. These certificates guarantee that a specific volume of electricity is generated from renewable-energy source (RES). More recently certificates (tradable white certificates (TWCs)) for the electricity saved by demand-side energy-efficiency measures (EEMs) have been introduced in some European countries. Recent advances in information and communication technology have opened up new possibilities for improving energy efficiency and increasing utilization of RESs. Use of technological resources such as the Internet and smart metering can permit real-time issuing and trading of TGCs. These technologies could also permit issuing of TWC. This paper reviews current renewable TGC and TWCs schemes in Europe and describes the possibilities for combining them in an Internet-based system. In the proposed combined tradable certificate scheme, both RESs and demand-side EEMs could bid in real time through the Internet to meet a specific obligation. The energy savings from the demand-side measures would be equivalent to the same amount of green electricity production. The paper describes the needed common targets and obligations, the certificate trading rules and the possible monitoring protocol. In particular, the paper focuses on the TWCs verification issues, including the assessment of the baseline, as these poses additional problems for TWCs compared to TGCs

  3. Energy savings in drastic climate change policy scenarios

    International Nuclear Information System (INIS)

    Isoard, Stephane; Wiesenthal, Tobias

    2005-01-01

    This paper reports a climate change policy scenario compatible with long-term sustainable objectives set at EU level (6th Environment Action Plan). By setting ambitious targets for GHG emissions reduction by 2030, this normative scenario relies on market-based instruments and flexible mechanisms. The integrated policy that is simulated (i.e. addressing energy, transport, agriculture and environmental impacts) constitutes a key outlook for the next 5-year report of the European Environment Agency (EEA). This scenario highlights what it would take to drastically curb EU GHG emissions and how much it might cost. The findings show that such a 'deep reduction' climate policy could work as a powerful catalyst for (1) substantial energy savings, and (2) promoting sustainable energy systems in the long term. The implications of this policy lever on the energy system are many-fold indeed, e.g. a substantial limitation of total energy demand or significant shifts towards energy and environment-friendly technologies on the supply side. Clear and transparent price signals, which are associated with market-based instruments, appear to be a key factor ensuring sufficient visibility for capital investment in energy efficient and environment-friendly options. Finally it is suggested that market-based policy options, which are prone to lead to win-win situations and are of particular interest from an integrated policy-making perspective, would also significantly benefit from an enhanced energy policy framework

  4. DEVELOPMENT OF A ENERGY SAVING GRAIN DRYING INVENTION

    Energy Technology Data Exchange (ETDEWEB)

    STEVE SHIVVERS

    2005-09-30

    The project goal is to develop the world's best grain dryer, where best is defined in terms of energy efficiency, grain quality protection, and minimal environmental impact. A technique was developed to recapture enthalpy from a continuous flow drying system and to carry that energy back into the grain kernels. Process design assures that the recaptured energy is used to provide latent heat for evaporation of moisture from the kernels. Maximum kernel temperatures are tightly controlled by the design and can be selected through the system controls. The drying system process has been simulated, the mechanical design for a prototype was completed, and the prototype has been fabricated and installed. Simulation results show energy use that is a fraction of that required by the most efficient heat assisted grain dryer systems available at this time. Unfortunately, project time has expired, funding has been exhausted, and the system has yet to be fully run in order to validate the process design. Additional development work is required to run tests with the prototype, improve the simulation model, optimize the process and mechanical design, and bring this energy saving system to market.

  5. Effectiveness Of UVC Lights Irradiation To Improve Energy Saving

    Directory of Open Access Journals (Sweden)

    Sameer A. Bilal

    2015-08-01

    Full Text Available HVAC Heating Ventilation and Air conditioning is the largest consumer of energy in commercial and industrial buildings. HVAC systems account for an approximated 50 of energy use in buildings. The sources of contamination and odour comes from the growth of bacteria mold and fungus that accumulate and develop on wet surfaces of HVAC coils and drain pans causing respiratory infection cough tight chest and wheezing. Besides the effects on human health Fungal contamination that adheres to the fins of cooling coil of air handling unit AHU cause a significant increase in pressure drop across the coil and decrease in heat exchange efficiency which Leeds to loss of cooling capacity and additional energy use. To prevent the fungal and microorganism growth on the cooling coil and drain pan of HVAC systems many studies conducted but not all these solutions were sufficient to remove microbial organism from the HVAC 100 . The UV-C light options through a process known as UVGI Ultraviolet germicidal irradiation is a technology showed a significant impact to produce clean air and improve indoor air quality 16. UVGI lights produce short wavelength light kills microorganisms including viruses bacteria mold and many other fungi by disrupting their DNA. The effectiveness of UVGI installed inside HVAC systems depends on many factors and the application Methods in HVAC systems. A few studies showed whether the use of UVGI results in energy saving. The objective of this study is to find the effect of fungal growth on the cooling coil surface by using field measurements at actual operating conditions of heat transfer and air flow for a non-irradiated coil in comparison to irradiated coil .Hence evaluate if there would be an enthalpy change at the coil and document the effectiveness of UVGI coil cleaning on restoring cooling capacity and save energy.

  6. An energy saving mechanism of EPON networks for real time video transmission

    Science.gov (United States)

    Liu, Chien-Ping; Wu, Ho-Ting; Chiang, Yun-Ting; Chien, Shieh-Chieh; Ke, Kai-Wei

    2015-07-01

    Modern access networks are constructed widely by passive optical networks (PONs) to meet the growing bandwidth demand. However, higher bandwidth means more energy consumption. To save energy, a few research works propose the dual-mode energy saving mechanism that allows the ONU to operate between active and sleep modes periodically. However, such dual-mode energy saving design may induce unnecessary power consumption or packet delay increase in the case where only downstream data exist for most of the time. In this paper, we propose a new tri-mode energy saving scheme for Ethernet PON (EPON). The new tri-mode energy saving design, combining the dual-mode saving mechanism with the doze mode, allows the ONU to switch among these three modes alternatively. In the doze mode, the ONU may receive downstream data while keeping its transmitter close. Such scenario is often observed for real time video downstream transmission. Furthermore, the low packet delay of high priority upstream data can be attained through the use of early wake-up mechanism employed in both energy saving modes. The energy saving and system efficiency can thus be achieved jointly while maintaining the differentiated QoS for data with various priorities. Performance results via simulation have demonstrated the effectiveness of such mechanism.

  7. SWEEP - Save Water and Energy Education Program; FINAL

    International Nuclear Information System (INIS)

    Sullivan, Gregory P; Elliott, Douglas B; Hillman, Tim C; Hadley, Adam; Ledbetter, Marc R; Payson, David R

    2001-01-01

    The objective of this study was to develop, monitor, analyze, and report on an integrated resource-conservation program highlighting efficient residential appliances and fixtures. The sites of study were 50 homes in two water-constrained communities located in Oregon. The program was designed to maximize water savings to these communities and to serve as a model for other communities seeking an integrated approach to energy and water resource efficiency. The program included the installation and in-place evaluation of energy- and water-efficient devices including the following: horizontal axis clothes washers (and the matching clothes dryers), resource-efficient dishwashers, an innovative dual flush low-flow toilet, low-flow showerheads, and faucet aerators. The significance of this activity lies in its integrated approach and unique metering evaluation of individual end-use, aggregated residential total use, and system-wide energy and water benefits

  8. Strategies for Power/Energy Saving in Distribution Networks

    Directory of Open Access Journals (Sweden)

    GRIGORAS, G.

    2010-05-01

    Full Text Available The power/energy losses reduction in distribution systems is an important issue during planning and operation, with important technical and economical implications. Thus, the energy losses minimization implies not only the technical improvement of the network, through its renewal with the introduction of the technological innovations in the equipment and circuit components as well as the optimal planning of the design and development of the network, but also requires the use of the methods and software tools to facilitate the operation process. The paper presents a strategy for power/energy saving which replacement of the 6 kV voltage level with 20 kV voltage level in correlation with the extent of using efficient transformers. In this line, different urban distribution networks were analyzed using fuzzy techniques.

  9. New 100 + Year Road RALE System With T-Beam Foundation Saves Energy and Increases Safety by Reducing Work Zones

    Science.gov (United States)

    Pressler, David

    2007-05-01

    Traffic crashes represents a loss of 2.2 percent of the U.S. Gross Domestic Product a year. By reducing congestion and the number of dangerous construction zones it is possible to increase user safety with fewer accidents. This new system once implemented eliminates many major national road preservation projects, which include replacing or reconstructing the highway pavements over the long period. Other included costs like those of lost time and lost fuel incurred by passenger and freight transportation on the section being reconstructed amount to well over 100 billion dollars a year. All other things being equal, thicker concrete highway pavements will last longer, however, thicker pavement costs more. By utilizing the physics of the T-Beam or the ``floor-joist,'' concept where the upper deck of the highway is supported and reinforced by longitude beams or rails that protrude into the soil, there is a great improvement in the strength of the pavement system. The pavement structure configuration of rails supports and carries vehicle loads, which is transferred ``down-the-road.'' Much like a snowshoe or like a rail bridge this device spreads out the applied stresses over a much larger area and the high strength pavement resists flexing of the concrete. Stress reduction reduces concrete fatigue and this allows the highway to last three to four times as long without major road reconstruction. To cite this abstract, use the following reference: http://meetings.aps.org/link/BAPS.2007.OSS07.P1.2

  10. Trigeneration primary energy saving evaluation for energy planning and policy development

    International Nuclear Information System (INIS)

    Chicco, Gianfranco; Mancarella, Pierluigi

    2007-01-01

    Trigeneration or combined heat, cooling and power (CHCP) is becoming an increasingly important energy option, particularly on a small-scale basis (below 1 MW e ), with several alternatives nowadays available for the cooling power production and the coupling to cogeneration systems. This paper deals with the introduction of a suitable framework for assessing the energy saving performance of trigeneration alternatives, orientated towards energy planning studies and the development of regulatory policies. In particular, a new generalized performance indicator-the trigeneration primary energy saving (TPES)-is introduced and discussed, with the aim of effectively evaluating the primary energy savings from different CHCP alternatives. The potential of the TPES indicator is illustrated through specific analyses run over different combinations of trigeneration equipment, providing numerical examples based on time-domain simulations to illustrate the dependence of the energy saving characteristics on the CHCP system configurations and equipment, as well as on the loading levels. In addition, the key aspect of adequately establishing the reference efficiencies for the conventional separate production of electrical, thermal and cooling power is addressed in detail. This aspect affects both equipment selection and potential profitability of the considered solutions under the outlook of receiving financial incentives

  11. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-10-14

    The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

  12. General Merchandise 50% Energy Savings Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E.; Leach, M.; Hirsch, A.; Torcellini, P.

    2009-09-01

    This report documents technical analysis for medium-box general merchandise stores aimed at providing design guidance that achieves whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.

  13. Crop based climate regimes for energy saving in greenhouse cultivation

    NARCIS (Netherlands)

    Körner, O.

    2003-01-01

    Key words: Biocides, cut chrysanthemum, Chrysanthemum grandiflorum , CO 2 , crop photosynthesis, DIF , energy saving, fungal diseases, humidity control, plant quality, simulation model, stem elongation, temperature integration.Sustainability is one of the major aims in greenhouse

  14. the Use of Solar Light for Energy Saving

    Directory of Open Access Journals (Sweden)

    Antonio Peña-García

    2011-01-01

    Full Text Available Shifting the threshold zone of road tunnels with semitransparent tension structures has shown itself to be an effective way of saving energy in regards to electricity consumption, maintenance, and construction materials used in the electrical lighting, thus lessening negative environmental impacts. Even though the shape of the tension structure has a major influence on energy savings, the optimal type of structure for each tunnel is often difficult to determine, because experiments using real tunnels are extremely expensive. It is thus necessary to find methods of doing this that are both reliable as well as economical. In this research study, three candidate structures were set up at the portal of a scale model of a real tunnel. The energy savings in each case were analyzed and compared. As a result, it was possible to formulate a new equation that calculates the energy savings in the threshold zone.

  15. Effect of lifestyle on energy use estimations and predicted savings

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.; Fuller, L.C.

    1988-03-01

    Audit predictions of energy-conservation savings are usually much higher than the savings actually achieved. Speculation about possible causes for this discrepancy has often centered around residents' lifestyle, specifically their indoor temperature management. Detailed indoor temperature data and extensive demographic information were available for 300 homes in Hood River, Oregon. These data were analyzed to examine the effect of demographic variables on indoor temperature and energy use. Changes in indoor temperature before and after retrofit were also examined. The effects of these variables were very small. Some small improvements to auditing procedures can be suggested based on this analysis. However, the major conclusion is that while some takeback of energy savings is occurring, it is very small in magnitude and cannot explain the large differences between predicted and achieved energy savings. 8 refs., 19 figs., 5 tabs.

  16. Savings potential of ENERGY STAR (registered trademark) voluntary labeling programs

    International Nuclear Information System (INIS)

    Webber, Carrie A.; Brown, Richard E.

    1998-01-01

    In 1993 the U.S. Environmental Protection Agency (EPA) introduced ENERGY STAR (registered trademark), a voluntary labeling program designed to identify and promote energy-efficient products. Since then EPA, now in partnership with the U.S. Department of Energy (DOE), has introduced programs for more than twenty products, spanning office equipment, residential heating and cooling equipment, new homes, commercial and residential lighting, home electronics, and major appliances. We present potential energy, dollar and carbon savings forecasts for these programs for the period 1998 to 2010. Our target market penetration case represents our best estimate of future ENERGY STAR savings. It is based on realistic market penetration goals for each of the products. We also provide results under the assumption of 100% market penetration; that is, we assume that all purchasers buy ENERGY STAR-compliant products instead of standard efficiency products throughout the analysis period. Finally, we assess the sensitivity of our target penetration case forecasts to greater or lesser marketing success by EPA and DOE, lower-than-expected future energy prices, and higher or lower rates of carbon emission by electricity generators. The potential savings of ENERGY STAR are substantial. If all purchasers chose Energy Star-compliant products instead of standard efficiency products over the next 15 years, they would save more than$100 billion on their energy bills during those 15 years. (Bill savings are in 1995 dollars, discounted at a 4% real discount rate.)

  17. Energy saving: From engineering to crop management

    NARCIS (Netherlands)

    Dieleman, J.A.; Hemming, S.

    2011-01-01

    In greenhouse horticulture, energy costs form an increasingly larger part of the total production costs. Energy is primarily used for temperature control, reduction of air humidity, increase of light intensity and CO2 supply. Use of fossil energy can be reduced by limiting the energy demand of the

  18. Energy saving behaviours: Development of a practice-based model

    International Nuclear Information System (INIS)

    Sweeney, Jillian C.; Kresling, Johannes; Webb, Dave; Soutar, Geoffrey N.; Mazzarol, Tim

    2013-01-01

    Financial pressure and concern for the environment has meant many consumers are aware of the need to reduce their consumption of many resources, including energy, which is the focus of the present study. While potential energy use deterrents in the form of access constraints and price increases are forms of extrinsic control, it is not clear how effective these are at reducing consumption and, indeed, it is not clear if such measures are consistent with people's underlying energy saving motivations. Beyond behavioural motivations, people's desires to reduce energy can be thwarted (barriers) and/or supported by a variety of factors, some within their control, while others are perhaps less so. Using a practice-based framework and a qualitative focus group approach, this study presents an exploratory study of these issues. Policy suggestions for overcoming barriers, as well suggestions as to how energy saving behaviours can be supported are offered. - Highlights: • We obtained consumers views about energy saving motivations, barriers and support. • Attitudes towards energy saving are not sufficient to change behaviours. • A practice-based approach to understanding energy saving behaviours is applied. • A practice-based energy-cultures framework (PBECF) is developed. • Barriers and support factors are identified that can be conceptualised within a PBECF

  19. A multifunctional energy-saving magnetic field generator

    Science.gov (United States)

    Xiong, Hui; Sun, Wanpeng; Liu, Jinzhen; Shi, Jinhua

    2018-03-01

    To improve the energy utilization of magnetic field generators for biological applications, a multifunctional energy-saving magnetic field generator (ESMFG) is presented. It is capable of producing both an alternating magnetic field (AMF) and a bipolar pulse magnetic field (BPMF) with high energy-saving and energy-reuse rates. Based on a theoretical analysis of an RLC second-order circuit, the energy-saving and energy-reuse rates of both types of magnetic fields can be calculated and are found to have acceptable values. The results of an experimental study using the proposed generator show that for the BPMF, the peak current reaches 130 A and the intensity reaches 70.3 mT. For the AMF, the intensity is 11.0 mT and the RMS current is 20 A. The energy-saving and energy-reuse rates for the AMF generator are 61.3% and 63.5%, respectively, while for the BPMF generator, the energy-saving rate is 33.6%. Thus, the proposed ESMFG has excellent potential for use in biomedical applications.

  20. Proceedings of VI International Conference for Renewable Energy, Energy Saving and Energy Education (CIER 2009)

    International Nuclear Information System (INIS)

    2009-01-01

    The CD-ROM presents papers submitted to the International Conference of Renewable Energy, Energy Saving and Energy Education. CIER 2009, held in Havana, Cuba, on Jun 9-13, 2009 May. The purpose of the CIER 2009 are to offer an opportunity to engineers, investigators, academic, makers and specialists in the energy topic from all over the world to exchange experiences, to share their successes and to discuss their focuses to future in the topic of the energy renewable, the energy saving, the energy efficiency and the energy education

  1. Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO)

    Energy Technology Data Exchange (ETDEWEB)

    McIntosh, Jane [MDA; Schumacher, Leon [University of Missouri

    2014-10-23

    The Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO) program brought together a team of representatives from government, academia, and private industry to enhance the availability of energy efficiency services for small livestock producers in the State of Missouri. The Missouri Department of Agriculture (MDA) managed the project via a subcontract with the University of Missouri (MU), College of Agriculture Food and Natural Resources, MU Extension, the MU College of Human Environmental Sciences, the MU College of Engineering, and the Missouri Agricultural and Small Business Development Authority (MASBDA). MU teamed with EnSave, Inc, a nationally-recognized expert in agricultural energy efficiency to assist with marketing, outreach, provision of farm energy audits and customer service. MU also teamed with independent home contractors to facilitate energy audits of the farm buildings and homes of these livestock producers. The goals of the project were to: (1) improve the environment by reducing fossil fuel emissions and reducing the total energy used on small animal farms; (2) stimulate the economy of local and regional communities by creating or retaining jobs; and (3) improve the profitability of Missouri livestock producers by reducing their energy expenditures. Historically, Missouri scientists/engineers conducted programs on energy use in agriculture, such as in equipment, grain handling and tillage practices. The MAESTRO program was the first to focus strictly on energy efficiency associated with livestock production systems in Missouri and to investigate the applicability and potential of addressing energy efficiency in animal production from a building efficiency perspective. A. Project Objectives The goal of the MAESTRO program was to strengthen the financial viability and environmental soundness of Missouri's small animal farms by helping them implement energy efficient technologies for the production facility, farm

  2. Potential for the Use of Energy Savings Performance Contracts to Reduce Energy Consumption and Provide Energy and Cost Savings in Non-Building Applications

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Charles; Green, Andrew S.; Dahle, Douglas; Barnett, John; Butler, Pat; Kerner, David

    2013-08-01

    The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) inits buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achieving savings in non-building applications.

  3. Management of Financing the Energy Saving in Terms of Construction Enterprises: International Experience

    Directory of Open Access Journals (Sweden)

    Klimchuk Marina N.

    2016-02-01

    Full Text Available The article is aimed at studying the experience of financing the energy saving projects by leading countries of the world from the perspective of adapting the contemporary management-regulatory conditions of technology in terms of enterprises of the construction complex of Ukraine. On the basis of a content analysis of the existing practices of implementation of energy saving and enhancing energy efficiency, the following classification has been suggested: depending on the institutional socio-economic and environmental development, in accordance with the course of sustainable development, depending on the structure of economic system, depending on both time interval and subsectoral characteristic. Based on a scientific approach to the five levels in the structure of economic systems, barriers and recommendations for their prevention in the management of energy saving in construction at each of these levels have been identified. The article proposes strategic priorities of the State policy of energy saving in the construction industry, in particular holding of energy audits and energy performance certification of buildings, increasing the share of renewable energy sources in the energy balance of country; implementation of contemporary concepts of energy saving ("Green Lease", "Passive House", "Triple Zero"; establishing consulting-information centers for promoting energy saving measures.

  4. Potential energy savings and thermal comfort

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Rudbeck, Claus Christian; Schultz, Jørgen Munthe

    1996-01-01

    Results of simulations carried out on four different buildings with common windows, commercial low-energy windows and xerogel windows are presented. The results are the annual energy consumption for space heating and the indoor air temperature level.......Results of simulations carried out on four different buildings with common windows, commercial low-energy windows and xerogel windows are presented. The results are the annual energy consumption for space heating and the indoor air temperature level....

  5. Energy savings in the Danish building stock until 2050

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Kragh, Jesper

    2014-01-01

    A study has been conducted analysing the energy savings for space heating and domestic hot water in the Danish building stock due to renovation of building components at the end of their service life. The purpose of the study was to estimate the energy savings until 2050 as building components...... are energy upgraded according to the requirements stipulated in the Danish Building Regulations 2010. Furthermore, scenario analyses was made for the potential impact on the energy consumption of introducing different levels of tightening of the energy requirements for existing buildings in the Danish...... Building Regulations. Compliance with the requirements in the Danish Building Regulations will potentially result in energy savings for space heating and domestic hot water around 30 % until 2050. Further tightening of the component insulation level requirements will only result in marginally higher...

  6. A novel sensor platform matching the improved version of IPMVP option C for measuring energy savings.

    Science.gov (United States)

    Tseng, Yen-Chieh; Lee, Da-Sheng; Lin, Cheng-Fang; Chang, Ching-Yuan

    2013-05-22

    It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon

  7. A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

    Directory of Open Access Journals (Sweden)

    Ching-Yuan Chang

    2013-05-01

    Full Text Available It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP was proposed by the Efficiency Valuation Organization (EVO to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS. A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the

  8. Computational Support for the Selection of Energy Saving Building Components

    NARCIS (Netherlands)

    De Wilde, P.J.C.J.

    2004-01-01

    Buildings use energy for heating, cooling and lighting, contributing to the problems of exhaustion of fossil fuel supplies and environmental pollution. In order to make buildings more energy-efficient an extensive set of âenergy saving building componentsâ has been developed that contributes to

  9. The use of environmental accounting to determine energy saving in Mpumalanga Hotels, South Africa

    CSIR Research Space (South Africa)

    Machete, Fannie

    2016-12-01

    Full Text Available saving characterisation should be based on a confirmed reduction of energy demand, cost and carbon footprint. However, the paper points out that the selection of energy saving technologies and characterisation of activities as energy saving method can...

  10. Customer-economics of residential photovoltaic systems (Part 1): The impact of high renewable energy penetrations on electricity bill savings with net metering

    International Nuclear Information System (INIS)

    Darghouth, Naïm R.; Barbose, Galen; Wiser, Ryan H.

    2014-01-01

    Residential photovoltaic (PV) systems in the US are often compensated at the customer's underlying retail electricity rate through net metering. Given the uncertainty in future retail rates and the inherent links between rates and the customer–economics of behind-the-meter PV, there is growing interest in understanding how potential changes in rates may impact the value of bill savings from PV. In this article, we first use a production cost and capacity expansion model to project California hourly wholesale electricity market prices under two potential electricity market scenarios, including a reference and a 33% renewables scenario. Second, based on the wholesale electricity market prices generated by the model, we develop retail rates (i.e., flat, time-of-use, and real-time pricing) for each future scenario based on standard retail rate design principles. Finally, based on these retail rates, the bill savings from PV is estimated for 226 California residential customers under two types of net metering, for each scenario. We find that high renewable penetrations can drive substantial changes in residential retail rates and that these changes, together with variations in retail rate structures and PV compensation mechanisms, interact to place substantial uncertainty on the future value of bill savings from residential PV. - Highlights: • We investigate the impact of high renewables on customer economics of solar. • We model three types of residential retail electricity rates. • Based on the rates, we calculate the bill savings from photovoltaic (PV) generation. • High renewables penetration can lead to lower bill savings with time-varying rates. • There is substantial uncertainty in the future bill savings from residential PV

  11. Honeywell starts energy-management service: savings guaranteed; BOSS replaced

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, R.

    1983-01-24

    Honeywell Inc. guarantees that its new Honeywell Service Link Operation (HSLO), a time-sharing service, will produce greater energy savings than its monthly fees. There are no front-end costs because the central computer is located at the supplier's Atlanta site, making energy management cost-affordable for facilities as small as 25,000 square feet. HSLO replaces Honeywell's Building Operations Service System (BOSS) that has a minimum-size requirement of 100,000 square feet. BOSS customers will be automatically changed to HSLO at no charge. All 21 regional computer centers will be available to users. Johnson Controls, Inc. also operates a time-sharing operation called Total Automated Building Services (TABS). (DCK)

  12. Evaluation of realised energy savings with simulation models. A new policy tool for the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M. [ECN Policy Studies, Petten (Netherlands)

    2013-01-15

    This report describes a new analysis tool for the evaluation of realised energy savings, and effects of savings policy, in the Netherlands. It aims to meet the information needs of policymakers, both at national and EU level, using the monitoring results of the NL Agency. The system builds on the Protocol Monitoring Energy Savings to calculate realised savings. The innovation consists of the option to adjust energy models per sector, as already used for scenario analysis, to simulate past developments. The simulations can estimate total savings and assess the contribution of policy measures. The detailed simulation approach also enables the decomposition of energy trends into volume-effects due to growth, structural effects such as fuel substitution and import/exports, and various saving effects. As the modeling system is already used for the analysis of future trends, it enables a good comparison between ex-ante (expected) savings and ex-post (realised) savings. Finally, the system enables a faster delivery of calculation results than presently is the case.

  13. A simple and efficient formula for saving electric energy in lighting systems; Una formula sencilla y eficaz para ahorrar energia electrica en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa Noriega, L. R. [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico, Mexico, D. F. (Mexico)

    1995-12-31

    In the Metropolitan Area of Mexico City, as well as in other regions with a similar climate, there are an important number of users of the electric energy service, whose main load consists of lighting, since systems such as environmental conditioning, refrigeration, pumping and others are either not necessary or lack of importance as electric energy consumers. These are classified in the range of small users that altogether represent a significant saving, but the precarious diffusion of the technological advances have not contemplated the need of carrying on corrective actions. Among these users are the offices, sites of entertainment and a range of commerces and services such as clothing stores, pharmacies, shoe stores, printing shops, dry cleaner`s, restaurants, barber shops, etc. The present paper pretends to provide a simple methodology easy to carry on, derived form a demonstrative project that FIDE (Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico) successfully carried out for the Club Deportivo Berinbau. [Espanol] En el area Metropolitana de la ciudad de Mexico, asi como en otras regiones con clima similar, existe un numero importante de usuarios del servicio de energia electrica cuya carga principal consiste en iluminacion, ya que sistemas como acondicionamiento ambiental, refrigeracion, bombeo y otros, o bien no son necesarios o carecen de la importancia en cuanto a consumo de energia electrica. Estos se catalogan dentro del rango de pequenos usuarios que en conjunto representan un potencial de ahorro significativo pero que, debido a la precaria difusion de los adelantos tecnologicos, no han contemplado la posibilidad de llevar a cabo acciones correctivas. Entre estos usuarios se encuentran oficinas, lugares de esparcimiento, planteles educativos y una gama de comercios y servicios como tiendas de ropa, farmacias, zapaterias, imprentas, tintorerias, restaurantes, peluquerias, etc. El presente trabajo pretende proporcionarles una

  14. Developments in indoor sustainable plant production with emphasis on energy saving

    NARCIS (Netherlands)

    Bot, G.P.A.

    2001-01-01

    In conventional greenhouse crop production the high level of energy input conflicts with international agreements on reduction of CO2 emission. To reduce absolute energy consumption, energy friendly greenhouse systems have to be designed. If today's available technology is applied energy saving will

  15. Sustainable roofs with real energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.; Petrie, T.W.

    1996-12-31

    This paper addresses the general concept of sustainability and relates it to the building owner`s selection of a low-slope roof. It offers a list of performance features of sustainable roofs. Experiences and data relevant to these features for four unique roofs are then presented which include: self-drying systems, low total equivalent warming foam insulation, roof coatings and green roofs. The paper concludes with a list of sustainable roofing features worth considering for a low-slope roof investment. Building owners and community developers are showing more interest in investing in sustainability. The potential exists to design, construct, and maintain roofs that last twice as long and reduce the building space heating and cooling energy loads resulting from the roof by 50% (based on the current predominant design of a 10-year life and a single layer of 1 to 2 in. (2.5 to 5.1 cm) of insulation). The opportunity to provide better low-slope roofs and sell more roof maintenance service is escalating. The general trend of outsourcing services could lead to roofing companies` owning the roofs they install while the traditional building owner owns the rest of the building. Such a situation would have a very desirable potential to internalize the costs of poor roof maintenance practices and high roof waste disposal costs, and to offer a profit for installing roofs that are more sustainable. 14 refs., 12 figs.

  16. Investigation of thin film energy-saving coatings

    Directory of Open Access Journals (Sweden)

    Bukhmirov Vyacheslav

    2017-01-01

    Full Text Available The report presents the results of an experimental study of the thermophysical properties and energy efficiency of thin-film energy-saving coatings consisting of hollow microspheres and a binder material from styrene-acrylic dispersion. The value of the thermal conductivity coefficient of the energy-saving paint is estimated depending on its composition and temperature, and the thermal diffusivity coefficient is determined. Experimental results of energy efficiency of using thin-film coatings for insulation of facades of buildings and as thermal insulation for pipelines with a hot coolant are presented.

  17. Saving energy for the data collection point in WBAN network

    Science.gov (United States)

    Nguyen-Duc, Toan; Kamioka, Eiji

    2017-11-01

    Wireless sensor networking (WSN) has been rapidly developed and become essential in various domains including health care systems. Such systems use WSN to collect real-time medical sensed data, aiming at improving the patient safety. For instance, patients suffered from adverse events, i.e., cardiac or respiratory arrests, are monitored so as to prevent them from getting harm. Sensors are placed on, in or near the patients' body to continuously collect sensing data such as the electrocardiograms, blood oxygenation, breathing, and heart rate. In this case, the sensors form a subcategory of WSN called wireless body area network (WBAN). In WBAN, sensing data are sent to one or more data collection points called personal server (PS). The role of PS is important since it forwards sensed data, to a medical server via a Bluetooth/WLAN connection in real time to support storage of information and real-time diagnosis, the device can also issue a notification of an emergency status. Since PS is a battery-based device, when its battery is empty, it will disconnect the sensed medical data with the rest network. To best of our knowledge, very few studies that focus on saving energy for the PS. To this end, this work investigates the trade-off between energy consumption for wireless communication and the amount of sensing data. An energy consumption model for wireless communication has been proposed based on direct measurement using real testbed. According to our findings, it is possible to save energy for the PS by selecting suitable wireless technology to be used based on the amount of data to be transmitted.

  18. Evaluation of methods used to determine realized energy savings

    International Nuclear Information System (INIS)

    Boonekamp, Piet G.M.

    2006-01-01

    Most methods to determine realized total energy savings at national or sectoral level make choices, or neglect problems, which hamper the calculation of sound and useful energy-saving figures. Issues are the choice of the right aggregation level, the appropriate variables to construct a reference energy consumption trend, the energy quantities to be applied and interaction between various effects. Uncertainty margins for results lack in most presentations as well. This paper presents six methods, illustrates the adverse effects of certain choices and problems, and investigates how these methods deal with them. The methods are scored with respect to the issues mentioned above. Finally, a number of improvements are suggested, among which the use of final energy demand expressed in primary energy units, and bottom-up analyses at the level of real saving options. The last option is the more important, as it could provide top-down evaluation results (total savings from decomposition) as well as bottom-up policy monitoring results, both being crucial to new European energy-saving policy

  19. Energy Saving Glass Lamination via Selective Radio Frequency Heating

    Energy Technology Data Exchange (ETDEWEB)

    Shawn M. Allan; Patricia M. Strickland; Holly S. Shulman

    2009-11-11

    Ceralink Inc. developed FastFuse™, a rapid, new, energy saving process for lamination of glass and composites using radio frequency (RF) heating technology. The Inventions and Innovations program supported the technical and commercial research and development needed to elevate the innovation from bench scale to a self-supporting technology with significant potential for growth. The attached report provides an overview of the technical and commerical progress achieved for FastFuse™ during the course of the project. FastFuse™ has the potential to revolutionize the laminate manufacturing industries by replacing energy intensive, multi-step processes with an energy efficient, single-step process that allows higher throughput. FastFuse™ transmits RF energy directly into the interlayer to generate heat, eliminating the need to directly heat glass layers and the surrounding enclosures, such as autoclaves or vacuum systems. FastFuse™ offers lower start-up and energy costs (up to 90% or more reduction in energy costs), and faster cycles times (less than 5 minutes). FastFuse™ is compatible with EVA, TPU, and PVB interlayers, and has been demonstrated for glass, plastics, and multi-material structures such as photovoltaics and transparent armor.

  20. Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Garibay Mendoza, V. [Lumisistemas, departamento de aseguramineto de calidad, Naucalpan (Mexico); Hernandez Bernal, J. M. [UNICORP, Mexico, D. F. (Mexico)

    1995-12-31

    In a lighting system the discharge lamps (fluorescent and high intensity discharge (HID)), ballast and controls are generating elements of harmonics. As a consequence of the tendency of saving energy, the use of electronic ballasts and controls that integrate dimmers, daylight and present sensors has increased in order to optimize the energy use. This paper presents the harmonics generation resulting from the fluorescent lamps operating different electronic ballasts as well as their electronic controls. Likewise, are also shown the effects caused by generation of harmonics components by the lighting system in the electric system that go from the voltage and current distortion, the presence of currents in the neutral conductor in balanced systems to the repercussions in the metering equipment such as watthour meters and the effects the lighting equipment suffer due to the presence of harmonics, such as the power factor decrease in ballasts that are of high power factor and the temperature increment in the magnetic type ballasts. [Espanol] Dentro de un sistema de iluminacion, las lamparas de descarga (fluorescentes y alta intensidad de descarga {sup H}ID{sup )}, balastros y los controles son elementos generadores de armonicas. A consecuencia de la tendencia al ahorro de energia se ha incrementado el uso de balastros electronicos y controles que integran atenuadores de luz (dimmers), sensores de luz natural y de presencia con el fin de optimizar el uso de la energia. Este trabajo presenta los resultados de generacion de armonicas para lamparas fluorescentes, operando diferentes balastros electronicos asi como con controles electronicos. Asi mismo son presentados los efectos causados por la generacion de componentes armonicas por el sistema de iluminacion dentro del sistema electrico que van desde la distorsion en voltaje y corriente, la presencia de corrientes dentro del conductor neutro en sistemas balanceados, asi como la repercusion en los equipos de medicion tales

  1. Keeping Energy Savings in the LOOP

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mercado, Andrea [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-11-01

    Mesa Lane Partners (MLP) partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to a build a new, low-energy mixed-use building that consumes at least 50% less energy than requirements set by Energy Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of America (IESNA), as part of DOE’s Commercial Building Partnerships (CBP)3 Program. Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program. The privately developed 46,000-square-foot LOOP project, which is intended to provide affordable off-campus student housing in an underserved community next to University of California at Santa Barbara, will contain more than 7,000 square feet of retail space, a roof deck, an event space, a gym, and 48 apartments. The project developer, MLP, is aiming to exceed CBP requirement, targeting energy consumption that is at least 65% less than that required by the standard. If the LOOP meets this goal, it is expected to achieve Leadership in Energy and Environmental Design (LEED) Gold certification. To meet this goal, the project design incorporates a variety of energy efficiency measures (EEMs) that address the needs of the multiple use types that the project will house.

  2. Does extending daylight saving time save energy? Evidence from an Australian experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kellogg, R. [California Univ., Berkeley, CA (United States). Dept. of Agricultural and Resource Economics; Wolff, H. [California Univ., Berkeley, CA (United States). Dept. of Agricultural and Resource Economics]|[Forschungsinstitut zur Zukunft der Arbeit (IZA), Bonn (Germany)

    2007-03-15

    Several countries are considering extending Daylight Saving Time (DST) in order to conserve energy, and the U.S. will extend DST by one month beginning in 2007. However, projections that these extensions will reduce electricity consumption rely on extrapolations and simulations rather than empirical evidence. This paper, in contrast, examines a quasiexperiment in which parts of Australia extended DST in 2000 to facilitate the Sydney Olympics. Using detailed panel data and a triple differences specification, we show that the extension did not conserve electricity, and that a prominent simulation model overstates electricity savings when it is applied to Australia. (orig.)

  3. Technical Support Document: Development of the Advanced Energy Design Guide for Large Hospitals - 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Leach, M.; Pless, S.

    2013-06-01

    This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Large Hospitals: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-LH) ASHRAE et al. (2011b). The AEDG-LH is intended to provide recommendations for achieving 50% whole-building energy savings in large hospitals over levels achieved by following Standard 90.1-2004. The AEDG-LH was created for a 'standard' mid- to large-size hospital, typically at least 100,000 ft2, but the strategies apply to all sizes and classifications of new construction hospital buildings. Its primary focus is new construction, but recommendations may be applicable to facilities undergoing total renovation, and in part to many other hospital renovation, addition, remodeling, and modernization projects (including changes to one or more systems in existing buildings).

  4. Energy efficiency monitoring and economic analysis for energy saving potential in UNITEN

    Science.gov (United States)

    Reyasudin Basir Khan, M.; Jidin, Razali; Pasupuleti, Jagadeesh; Yew, Kang Chin; Azwa Shaaya, Sharifah

    2013-06-01

    This paper discusses on energy efficiency survey for typical buildings in Universiti Tenaga Nasional (UNITEN). Undeniably, wastage of energy will cause the increase of operation cost and depletion of fossil fuel resources which contributes to the climate change issue in the world. UNITEN was commenced in the late 1990s and most of the buildings in this university are not equipped with energy management system. Such system is the solution to reduce energy use while maximizing the comfort levels of the occupants. Disregard to the energy management system, the implementation of other energy saving measures is the main objective of this paper. By taking the right measures, the energy wastage in the buildings of this university can be reduced.

  5. Potential of energy savings in the hotel sector in Jordan

    International Nuclear Information System (INIS)

    Ali, Yahya; Mustafa, Mairna; Al-Mashaqbah, Shireen; Mashal, Kholoud; Mohsen, Mousa

    2008-01-01

    This paper presents some insights into Jordan's energy consumption in the tourist accommodation sector. The results of a recent survey on environmental performance in the tourist accommodation sector in Jordan were used to evaluate energy conservation in hotels. A survey was designed and distributed to hotels' managers and departments' supervisors in order to understand the environmental performance in the tourist accommodation sector in Jordan during the period 10-17 August 2006. Also some field visits were conducted to fully understand hotels interaction regarding the environment, in addition to help interpreting the results of the survey. The study is limited to all classified hotels in Jordan. It was found that lighting hotels' main building and outside areas, and air conditioning consume more electricity compared to other departments. The results show that few classified hotels already installed energy saving equipments, though, it was noticed that managers of one star hotels were not really willing to make such changes in their hotels, on the other hand, other classified hotels (2-5 star hotels) have shown a high willingness to make changes in their hotels to reduce the consumption of different types of energy. Hotel's classification played a significant role in explaining variations in most of the results, particularly when it comes to long-term investments to reduce energy consumption by using energy efficient appliances. Five and four star hotels were the most hotels willing to use energy efficient appliances to reduce energy consumption. The study suggested some strategies to help reduce the negative impacts of high energy consumption in hotels. These strategies include better insulation, and enhanced insulation for the hot water reticulation system. Moreover, enhancing and increasing the level of awareness among all hoteliers through a directed and well-designed campaign. Also offer interest free loans; and activate precise standards and specifications

  6. Energy saving scheme for internet provision in rural africa: LESS

    CSIR Research Space (South Africa)

    Masonta, MT

    2010-05-01

    Full Text Available are among the reasons for the growing digital divide gap. In this paper, we present a Low cost Energy Saving Scheme Medium Access Control (LESS-MAC) protocol for broadband wireless networks suitable for deployments in energy-constrained rural areas. Our...

  7. Water and energy saving bioprocess for bioethanol production from ...

    African Journals Online (AJOL)

    Water and energy saving bioprocess for bioethanol production from corn grain applying stillage liquid part recirculation. ... from corn constitutes the way which could significantly reduce the water and energy consumption, what essentially reduce whole general production costs without ethanol efficiency decreasing.

  8. Energy-saving technologies of cultivation of sugar sorghum

    Science.gov (United States)

    Kashapov, N. F.; Nafikov, M. M.; Gilmanshin, I. R.; Gazetdinov, M. Kh; Nafikova, M. M.; Nigmatzyanov, A. R.

    2017-09-01

    The article describes the main elements of energy-saving technologies of cultivation of sugar sorghum, which, in particular, is the introduction of the combined units. Integrated units allow for one pass across the field to perform up to eight operations, thereby ensuring a significant reduction in energy costs, but there are certain negative points.

  9. The Association between Energy Saving and Guest Comfort in ...

    African Journals Online (AJOL)

    This article presents the association between energy saving in guesthouses and guest comfort. The study was conducted in the Mpumalanga Province, one of the nine provinces of South Africa and a leading tourism destination. The focus was to determine the relationship between energy reduction and its impact on the ...

  10. Methods for assessing the energy-saving efficiency of industrial symbiosis in industrial parks.

    Science.gov (United States)

    Li, Wenfeng; Cui, Zhaojie; Han, Feng

    2015-01-01

    The available energy resources are being depleted worldwide. Industrial symbiosis (IS) provides a promising approach for increasing the efficiency of energy utilization, with numerous studies reporting the superiority of this technology. However, studies quantifying the energy-saving efficiency of IS remain insufficient. This paper proposes an index system for the quantitative evaluation of the energy-saving efficiency of IS. Both energy-saving and financial indexes were selected, the former include the IS energy-saving index, the contribution rate of energy saved through IS, fractional energy savings, and cut rate of energy consumption per total output value; and the latter include the IS investment payback period, IS input-output ratio, net present value (NPV), and internal rate of return (IRR) of IS. The proposed methods were applied to a case study on the XF Industrial Park (XF IP), in the city of Liaocheng in Shandong Province of China. Three energy-saving channels using IS were found in the XF IP: (a) utilizing the energy of high-temperature materials among industrial processes, (b) recovering waste heat and steam between different processes, and (c) saving energy by sharing infrastructures. The results showed that the energy efficiency index of IS was 0.326, accounting for 34.6% of the comprehensive energy-saving index in 2011, and the fractional energy-savings were 12.42%. The index of energy consumption per total industrial output value varied from 90.9 tce/MRMB to 51.6 tce/MRMB. Thus, the cut rate of energy consumption per total industrial output value was 43.42%. The average values of the IS input-output ratio was 406.2 RMB/tce, 57.2% lower than the price of standard coal. Static investment payback period in the XF IP was 8.5 months, indicating that the XF IP began to earn profit 8.5 months after the construction of all IS modes. The NVP and IRR of each IS mode in the XF IP were greater than zero, with average values equal to 1,789.96 MRMB and 140

  11. CHP Energy and Emissions Savings Calculator

    Science.gov (United States)

    Download the CHP Emissions Calculator, a tool that calculates the difference between the anticipated carbon dioxide, methane, nitrous oxide, sulfur dioxide, and nitrogen oxide emissions from a CHP system to those of a separate heat and power system.

  12. Novel energy saving technologies evaluation tool

    NARCIS (Netherlands)

    Klemeš, J.; Bulatov, I.; Koppejan, J.

    2009-01-01

    The lead-time for the development of a new energy technology, from the initial idea to the commercial application, can take many years. The reduction of this time has been the main objective of the EC DGTREN, who have funded two related recent projects, EMINENT and EMINENT2 (Early Market

  13. Saving energy via high-efficiency fans.

    Science.gov (United States)

    Heine, Thomas

    2016-08-01

    Thomas Heine, sales and market manager for EC Upgrades, the retrofit arm of global provider of air movement solutions, ebm-papst A&NZ, discusses the retrofitting of high-efficiency fans to existing HVAC equipment to 'drastically reduce energy consumption'.

  14. Evaluation of environmental benefits and energy saving of urban heating systems; Valutazione dei benefici ambientali e del risparmio energetico dei sistemi diriscaldamento urbano

    Energy Technology Data Exchange (ETDEWEB)

    Bazzano, E. [CISE, Milan (Italy); Cancelli, F. [ASM, Brescia (Italy); Bassi, F.; Corso, S. [AEM, Milan (Italy); Franceschelli, F. [AMI, Imola (Italy); Caminiti, N.; Casagrande, A.; Degli Espinosa, P. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Energia; Fraternali, D. [Servizi Territoriali, Cinisello Balsamo, Milan (Italy); Riva, A. [SNAM, San Donato Milanese, Milan (Italy); Magnelli, T.

    1995-10-01

    Scope of the report is the definition of environmental benefits and energy saving potential achievable through application of CHP-DH (Combined Heat Power and District Heating) to the Italian situation. An economic analysis is also performed to the actual Italian institutional and legislative frame, and is achievable through a full exploitation of available economic resources and provided local decision-makers be significantly involved in the process. The assessment is based on experience coming from existing CHP-DH plants, or from plant designs yet in advanced development stage, adopting proven technologies.

  15. Achieving Energy Savings in Municipal Construction in Long Beach, CA

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Regnier, Cindy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-01-01

    Long Beach Gas and Oil (LBGO), the public gas utility in Long Beach, California, partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to build a new, low-energy modular office building that is at least 50% below requirements set by Energy Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) program.3 The LBGO building, which demonstrates that modular construction can be very energy efficient, is expected to exceed the ASHRAE baseline by about 45%. The new 15,000-square foot (ft2) LBGO office building has two stories and houses private offices, open-plan cubicle offices, and a conference room and call center on the second floor. The building’s modular nature allowed LBGO to realize the cost benefits of fasttracked construction while saving substantial energy and reducing operational costs. The project was funded by the utility’s ratepayer revenue, which imposed a tight budget limit. The design process was a collaborative effort involving LBGO and its design-build team, Lawrence Berkeley National Laboratory (Berkeley Lab), and subcontractors Stantec (formerly Burt Hill) and LHB Inc. The team proposed efficiency measures based on computer modeling of the building in full compliance with ASHRAE 90.1-2007; in the modeled building, the lighting and cooling systems were the largest energy users, so increasing the efficiency of these systems was a top priority. Promising measures were modeled to estimate their energy performance, and each measure was evaluated for its feasibility within the budget.

  16. The Impact of Process Scaling on Scratchpad Memory Energy Savings

    Directory of Open Access Journals (Sweden)

    Bennion Redd

    2014-09-01

    Full Text Available Scratchpad memories have been shown to reduce power consumption, but the different characteristics of nanometer scale processes, such as increased leakage power, motivate an examination of how the benefits of these memories change with process scaling. Process and application characteristics affect the amount of energy saved by a scratchpad memory. Increases in leakage as a percentage of total power particularly impact applications that rarely access memory. This study examines how the benefits of scratchpad memories have changed in newer processes, based on the measured performance of the WIMS (Wireless Integrated MicroSystems microcontroller implemented in 180- and 65-nm processes and upon simulations of this microcontroller implemented in a 32-nm process. The results demonstrate that scratchpad memories will continue to improve the power dissipation of many applications, given the leakage anticipated in the foreseeable future.

  17. Energy Saving by Novel Bed-Integrated Local Exhaust Ventilation

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Kehayova, Nushka; Melikov, Arsen Krikor

    2016-01-01

    was used alone at 4, 6 and 12 ACH. The air exhausted through the mattress was 1.5 L/s. The occupants were present 24 hours every day including weekends. Compared to the CAV ventilation used alone at 4, 6 and 12 ACH the use of the VM in the single-bed room decreased the annual energy consumption......-bed hospital patient room (1.3 air changes per hour (ACH)) and double-bed patient room (1.6 ACH) was assessed by means of dynamic computer simulations. The estimated annual energy consumption for the rooms using the VM combined with CAV was compared to the annual energy consumption when the CAV ventilation...... the mattress to the exhaust of the room background ventilation system. Comprehensive research reveals that the method is highly efficient for removal of bio-effluents. The energy saving potential of the VM combined with constant air volume (CAV) ventilation operating at reduced ventilation rate in a single...

  18. Comparison of Software Models for Energy Savings from Cool Roofs

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [ORNL; Miller, William A [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2014-01-01

    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

  19. TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    A. E. Denysova

    2017-09-01

    Full Text Available The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.

  20. Does energy labelling on residential housing cause energy savings? Working paper

    Energy Technology Data Exchange (ETDEWEB)

    Kjaerbye, V.H.

    2008-12-15

    More than 80% of energy used in households is dedicated to space heating. Large potential energy savings have been identified in the existing housing stock. Energy labelling of single-family houses is seen as an important instrument to provide new house owners with information on efficient energy saving investments that can be made on the house. This paper evaluates the effects of the Danish Energy Labelling Scheme on energy consumption in existing single-family houses with propensity score matching using actual consumption of energy and register data describing the houses and households. We do not find significant energy savings due to the Danish Energy Labelling Scheme. (Author)

  1. DETERMINING ENERGY SAVINGS IN BUILDINGS USING THE REDUCING COSTS METHOD

    Directory of Open Access Journals (Sweden)

    STAN IVAN F.E.

    2015-03-01

    Full Text Available The paper is structured in four parts. The first part presents the importance of thermal insulation for buildings energy economy and some insulation properties. In the second part of the paper it is described the reducing cost method to determine the energy savings. The third part of the paper includes an analysis and a comparison for an exterior wall provided with different thicknesses of insulation layer in order to determine the average savings cost. The last part presents conclusions and discussion.

  2. Traffic-aware Elastic Optical Networks to leverage Energy Savings

    DEFF Research Database (Denmark)

    Turus, Ioan; Fagertun, Anna Manolova; Dittmann, Lars

    2014-01-01

    Because of the static nature of the deployed optical networks, large energy wastage is experienced today in production networks such as Telecom networks . With power-adaptive optical interfaces and suitable grooming procedures, we propose the design of more energy efficient transport networks......-Europea n COST37 network, for both symbol-rate and modulation format adaptations significant savings are obtained . Mixed adaptation (jointly performing symbol-rate and modulation format adaptations) used together with optical grooming allows up to 4 4 % and 4 7 % power savings in DT17 and COST37 networks...

  3. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Ahlfeldt, Christopher [Navigant Consulting, Inc., Burlington, MA (United States); Hiraiwa, Hirokazu [Navigant Consulting, Inc., Burlington, MA (United States); Sathe, Amul [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States)

    2009-12-01

    This study characterizes and assesses the appliances used in commercial buildings. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development and demonstration (RD&D) opportunities for efficiency improvements, excluding product categories such as HVAC, building lighting, refrigeration equipment, and distributed generation systems. The study included equipment descriptions, characteristics of the equipment’s market, national energy consumption, estimates of technical potential for energy-saving technologies, and recommendations for U.S. Department of Energy programs that can promote energy savings in commercial appliances.

  4. The Program Administrator Cost of Saved Energy for Utility Customer-Funded Energy Efficiency Programs

    Energy Technology Data Exchange (ETDEWEB)

    Billingsley, Megan A.; Hoffman, Ian M.; Stuart, Elizabeth; Schiller, Steven R.; Goldman, Charles A.; LaCommare, Kristina

    2014-03-19

    End-use energy efficiency is increasingly being relied upon as a resource for meeting electricity and natural gas utility system needs within the United States. There is a direct connection between the maturation of energy efficiency as a resource and the need for consistent, high-quality data and reporting of efficiency program costs and impacts. To support this effort, LBNL initiated the Cost of Saved Energy Project (CSE Project) and created a Demand-Side Management (DSM) Program Impacts Database to provide a resource for policy makers, regulators, and the efficiency industry as a whole. This study is the first technical report of the LBNL CSE Project and provides an overview of the project scope, approach, and initial findings, including: • Providing a proof of concept that the program-level cost and savings data can be collected, organized, and analyzed in a systematic fashion; • Presenting initial program, sector, and portfolio level results for the program administrator CSE for a recent time period (2009-2011); and • Encouraging state and regional entities to establish common reporting definitions and formats that would make the collection and comparison of CSE data more reliable. The LBNL DSM Program Impacts Database includes the program results reported to state regulators by more than 100 program administrators in 31 states, primarily for the years 2009–2011. In total, we have compiled cost and energy savings data on more than 1,700 programs over one or more program-years for a total of more than 4,000 program-years’ worth of data, providing a rich dataset for analyses. We use the information to report costs-per-unit of electricity and natural gas savings for utility customer-funded, end-use energy efficiency programs. The program administrator CSE values are presented at national, state, and regional levels by market sector (e.g., commercial, industrial, residential) and by program type (e.g., residential whole home programs, commercial new

  5. Engaging energy saving through motivation-specific social comparison

    OpenAIRE

    Petkov, Petromil;Köbler, Felix;Foth, Marcus;Medland, Richard C.;Krcmar, Helmut

    2014-01-01

    Comparison is widely used in research projects and commercial products whose goal is to motivate energy saving at home. This research builds on fundamental theories from social psychology in an attempt to shed light on how to motivate consumers to conserve energy by providing relevant people for social comparison depending on consumer?s motivation to compare. To support the research process, the mobile application EnergyWiz was developed through a theory-driven design approach. Along with oth...

  6. Energy savings opportunities in the global digital television transition

    OpenAIRE

    Park, WY; Gopal, A; Phadke, A

    2017-01-01

    © 2016, The Author(s). Globally, terrestrial television (TV) broadcasting is in the midst of a complete transition to digital signals. The last analog terrestrial broadcast is expected to be switched off in the early 2020s. This transition presents huge energy savings opportunities that have thus far been ignored. Digital TV switchovers have likely increased energy consumption as countries have completed transitions by providing digital TV converters to analog TV users, which increase energy ...

  7. Future of energy savings policy in Denmark (in Japanese)

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    2007-01-01

    After a brief description of Denmark, its energy development and CO2 emission is outlined, especially in the years after 1973. Energy consumption within the country has remained almost constant, but including the country's large merchant fleet, energy consumption has grown by more than 50% to now...... 260 GJ annually per person. Danish energy saving policies with energy taxes, etc. are described. One important measure has been the use of heat from combined heat and power plants to heat buildings, which used to account for 40% of all energy consumption....

  8. Proceedings of VII International Conference for Renewable Energy, Energy Saving and Energy Education (CIER 2011)

    International Nuclear Information System (INIS)

    2011-01-01

    In this work scientists, engineers, manufactures, investors, policy makers, energy users, businessmen and other specialists present their professional experiences and commercial samples with view to reach common objectives in a climate of friendship and solidarity. Within the conference's framework there will be multiple workshops in Renewable Energy, Energy Saving and Energy Education and related fields. CIER provides an excellent platform to share experiences and promote synergies towards the challenge of achieving a sustainable energy culture

  9. Proceedings of VI International Conference for Renewable Energy, Energy Saving and Energy Education (CIER 2009)

    International Nuclear Information System (INIS)

    2009-01-01

    In this work scientists, engineers, manufactures, investors, policy makers, energy users and other specialists present their professional experiences and commercial samples with view to reach common objectives in a climate of friendship and solidarity. Within the conference's framework there will be multiple workshops in Renewable Energy, Energy Saving and Energy Education and related fields. CIER provides an excellent platform to share experiences and promote synergies towards the challenge of achieving a sustainable energy culture

  10. Energy Savings Assessment for Digital-to-Analog Converter Boxes

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Hoi Ying Iris; Meier, Alan; Brown, Richard

    2011-01-18

    The Digital Television (DTV) Converter Box Coupon Program was administered by the U.S. government to subsidize purchases of digital-to-analog converter boxes, with up to two $40 coupons for each eligible household. In order to qualify as Coupon Eligible Converter Boxes (CECBs), these devices had to meet a number of minimum performance specifications, including energy efficiency standards. The Energy Star Program also established voluntary energy efficiency specifications that are more stringent than the CECB requirements. In this study, we measured the power and energy consumptions for a sample of 12 CECBs (including 6 Energy Star labeled models) in-use in homes and estimated aggregate energy savings produced by the energy efficiency policies. Based on the 35 million coupons redeemed through the end of the program, our analysis indicates that between 2500 and 3700 GWh per year are saved as a result of the energy efficiency policies implemented on digital-to-analog converter boxes. The energy savings generated are equivalent to the annual electricity use of 280,000 average US homes.

  11. Development of Design Guidance for K-12 Schools from 30% to 50% Energy Savings: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Torcellini, P.; Long, N.

    2008-07-01

    This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating.

  12. Saving more to consume more. EDF's communication ambiguities during the energy saving era

    International Nuclear Information System (INIS)

    Bouvier, Yves

    2012-01-01

    Since 1974, EDF is placed between a communication scheme imposed for energy savings and an industrial strategy of massive investment in nuclear power. In ten years, the company managed to increase households electricity consumption without advertising, due in particular to electric heating. But strong tensions were generated by this situation and led the company to develop an institutional communication to the employees and to the general public

  13. Evaluation of Daylight Availability for Energy Savings

    Directory of Open Access Journals (Sweden)

    Laura Bellia

    2015-06-01

    Full Text Available Dynamic daylight simulations are very useful instruments in daylighting design process. They allow an in depth analysis of indoor daylight availability levels and define if they are adequate to perform a particular visual task. Their results can be used to design shading devices or lighting control systems and compare different technical solutions. The use of these simulations is likely to spread in the common design practice since some regulations and green building rating systems suggest their use. This paper presents dynamic daylight simulation results related to an open-plan office, performed with Autodesk 3ds Max Design®, which is a calculation software validated by recent researches. It is not used in academic context but it is very widespread between technicians for photorenderings production purposes. The goal of this research is to demonstrate the functionality of this software also in dynamic daylight simulations field and propose an analysis' methodology to use it.

  14. Dual-Cell HSDPA for Network Energy Saving

    DEFF Research Database (Denmark)

    Micallef, Gilbert

    2010-01-01

    The increasing demand for mobile broadband is pushing existing 3G networks closer to their capacity limit. Additional carriers together with new HSPA features (HSPA+) are expected to provide the next necessary boost in network capacity. One specific feature in HSPA+ is referred to as Dual...... consumption. This paper proposes an energy saving feature that exploits variations in network traffic. Based on the individual load of each sector, the feature determines if the secondary carrier is detrimental for reaching some pre-set minimum requirements. Each sector is allowed to switch off one...... of their two carriers, during periods of low network traffic. It is concluded that an energy saving ranging between 14% and 36% is possible. This saving comes without degradation of network performance....

  15. Electric energy savings from new technologies. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.; Imhoff, K.L.; Fisher, Z.J.

    1986-09-01

    Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for 10 technologies were prepared. The total projected annual savings for the year 2000 for all 10 technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In the Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference projection, only 25% of the savings estimated here should be subtracted from the reference projection for analysis purposes.

  16. Energy Saver: Tips on Saving Energy and Money in Your Home

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Allison L [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-04

    This guide shows you how easy it is to reduce your energy use at home and on the road. You'll find quick tips you can use to start saving today, as well as information on larger projects that will help save you money over the long term. Find even more information about saving money and energy at home by visiting our website, EnergySaver.gov.

  17. Energy-saving methodology for material handling applications

    Energy Technology Data Exchange (ETDEWEB)

    Makris, P.A.; Makri, A.P.; Provatidis, C.G. [National Technical University of Athens, School of Mechanical Engineering, Mechanical Design and Control Systems Division, 9 Iroon Polytechniou Street, Zografou Campus, GR-15773 Athens (Greece)

    2006-10-15

    This paper presents an energy saving approach to the problem of order picking in warehousing environment, which is directly related to the well-known Traveling Salesman Problem (TSP). While the available heuristic algorithms for the order-picking problem search for the route that minimizes the travel time, here the problem is addressed from the energy saving point of view. In a few words, the least energy-consuming route is identified in order to quantify the trade off in time and energy between the fastest route and the most energy economic one. Keeping in mind that often energy is as important as time, especially during a low-demand period, the current paper sheds some light into a two dimensional way of addressing the warehouse material handling problem, which saves time as well as energy. A very interesting finding is that a relatively small loss of service time in many cases may lead to a significant decrease of consumed energy without any additional cost. (author)

  18. Investing EU ETS auction revenues into energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Sijm, J.P.M.; Boonekamp, P.G.M. [ECN Policy Studies, Petten (Netherlands); Summerton, P.; Pollitt, H.; Billington, S. [Cambridge Econometrics CE, Cambridge (United Kingdom)

    2013-05-15

    The overall objective of this study is to analyse the effects of using EU ETS auction revenues to stimulate investments in energy savings in three key target sectors, i.e. Households, Tertiary and Industry (including both ETS and non-ETS industrial installations). The scenarios used refer basically to the situation before the recent agreement on the Energy Efficiency Directive (EED) and include (a mixture of) different policy options to enhance energy savings in the target sectors, in particular (1) reducing the ETS cap, (2) introducing an Energy Efficiency Obligation (EEO) for energy suppliers or distributors, and/or (3) using ETS auction revenues to support additional (private) investments in raising energy efficiency. In order to meet this objective a variety of different policy scenarios have been defined and analysed by means of the 'Energy-Environment-Economy Model for Europe (E3ME)'. The study presents and discusses a large variety of scenario modelling results by the year 2020 at the EU27 level. These results refer to, among others, energy savings, GHG emissions, the ETS carbon price, household electricity bills and to changes in some macro- or socio-economic outcomes such as GDP, inflation, employment or international trade. Finally, the study discusses some policy findings and implications, including options to enhance the effectiveness of some EE policies, in particular those having a potential adverse effect on the ETS carbon price.

  19. Walmart - Saving Energy, Saving Money Through Comprehensive Retrofits, Commercial Building Energy Efficiency (Fact Sheet); Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-01

    Walmart partnered with the U.S. Department of Energy (DOE) in 2009 to develop and demonstrate energy retrofits for existing buildings. The goal was to reduce energy consumption by at least 30% versus ASHRAE Standard 90.1-2007, as part of DOE's Commercial Building Partnerships (CBP) Program. The project presented here, the retrofit of a 213,000 square foot store in Centennial, Colorado, withefficiency measures across multiple building systems, is part of Walmart's ongoing environmental sustainability program, which originated in 2005.

  20. Facilitating Energy Savings through Enhanced Usability of Thermostats

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan; Aragon, Cecilia; Peffer, Therese; Perry, Daniel; Pritoni, Marco

    2011-05-23

    Residential thermostats play a key role in controlling heating and cooling systems. Occupants often find the controls of programmable thermostats confusing, sometimes leading to higher heating consumption than when the buildings are controlled manually. A high degree of usability is vital to a programmable thermostat's effectiveness because, unlike a more efficient heating system, occupants must engage in specific actions after installation to obtain energy savings. We developed a procedure for measuring the usability of thermostats and tested this methodology with 31 subjects on five thermostats. The procedure requires first identifying representative tasks associated with the device and then testing the subjects ability to accomplish those tasks. The procedure was able to demonstrate the subjects wide ability to accomplish tasks and the influence of a device's usability on success rates. A metric based on the time to accomplish the tasks and the fraction of subjects actually completing the tasks captured the key aspects of each thermostat's usability. The procedure was recently adopted by the Energy Star Program for its thermostat specification. The approach appears suitable for quantifying usability of controls in other products, such as heat pump water heaters and commercial lighting.

  1. Energy saving work of frequency controlled induction cage machine

    International Nuclear Information System (INIS)

    Gnacinski, P.

    2007-01-01

    Energy saving work, understood as lowering the supply voltage when load torque is much less than rated, is one way of reducing power losses in an induction cage machine working with a variable load. Reduction in power losses also affects the thermal properties of an induction machine because the energy saving work allows the temperature rise of the windings to decrease. Thanks to a lower temperature of the windings, the same load torque can be carried by a machine of less rated power. The ability of energy saving work to reduce the temperature of windings depends on the thermal properties of an induction machine, which are different in the case of a machine with foreign ventilation and its own ventilation. This paper deals with the thermal effect of energy saving work on a frequency controlled induction cage machine. A comparison of the properties of a machine with its own and outside ventilation is presented. The results of the investigations are shown for a 3 kW induction cage machine with the two previously mentioned ways of ventilation: one provided with a fan placed on a shaft and the other provided with a fan driven by an auxiliary motor

  2. Energy Saving Bulbs: An Emerging Threat to Public Health, from ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    SUMMARY. Energy saving bulbs are promoted for their efficiency and capacity to reduce the emission of greenhouse gases, the acknowledged cause of global warming and climate change. They however contain varying quantity of mercury that can easily contaminate the environment. Mercury is a neuro-toxin, but ...

  3. Energy-saving technology choices by Dutch glasshouse firms

    NARCIS (Netherlands)

    Pietola, K.; Oude Lansink, A.G.J.M.

    2006-01-01

    This paper estimates a sequence of energy-saving technology choices by Dutch glasshouse firms. The model allows for time-constant, firm-specific effects and serial correlation of errors and it is estimated on panel data over the period 1991¿1995. The unobserved error sequences are simulated in the

  4. Leveraging Lighting for Energy Savings: GSA Northwest/Artic Region

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-01-01

    Case study describes how the Northwest/Arctic Region branch of the General Services Administration (GSA) improved safety and energy efficiency in its Fairbanks Federal Building parking garage used by federal employees, U.S. Marshals, and the District Court. A 74% savings was realized by replacing 220 high-pressure sodium fixtures with 220 light-emitting diode fixtures.

  5. Energy Saving Bulbs: An Emerging Threat to Public Health, from ...

    African Journals Online (AJOL)

    Energy saving bulbs are promoted for their efficiency and capacity to reduce the emission of greenhouse gases, the acknowledged cause of global warming and climate change. They however contain varying quantity of mercury that can easily contaminate the environment. Mercury is a neuro-toxin, but damage has also ...

  6. Effectiveness of energy renovations: a reassessment based on actual consumption savings

    OpenAIRE

    Filippidou, F.; Nieboer, N.E.T.; Visscher, H.J.

    2018-01-01

    Energy renovations offer unique opportunities to increase the energy efficiency of the built environment and for the existing housing stock; they are the most important solution. Usually, energy savings are based on modeling calculations. However, recent research has shown that the predicted energy consumption differs largely from the actual consumption. In this paper, the effectiveness of energy measures is re-assessed based on actual consumption data. We use a monitoring system, which conta...

  7. Advisory Systems Save Time, Fuel for Airlines

    Science.gov (United States)

    2012-01-01

    Heinz Erzberger never thought the sky was falling, but he knew it could benefit from enhanced traffic control. Throughout the 1990s, Erzberger led a team at Ames Research Center to develop a suite of automated tools to reduce restrictions and improve the efficiency of air traffic control operations. Called CTAS, or Center-TRACON (Terminal Radar Approach Control) Automation System, the software won NASA s Software of the Year award in 1998, and one of the tools in the suite - the traffic management advisor - was adopted by the Federal Aviation Administration and implemented at traffic control centers across the United States. Another one of the tools, Direct-To, has followed a different path. The idea behind Direct-To, explains Erzberger, a senior scientist at Ames, was that airlines could save fuel and money by shortening the routes they flew between take-off and landing. Aircraft are often limited to following established airways comprised of inefficient route segments. The routes are not easily adjusted because neither the pilot nor the aircraft controller can anticipate the constantly changing air traffic situation. To make the routes more direct while in flight, Erzberger came up with an idea for a software algorithm that could automatically examine air traffic in real-time, check to see if a shortcut was available, and then check for conflicts. If there were no conflicts and the shortcut saved more than 1 minute of flight time, the controller could be notified. "I was trying to figure out what goes on in the pilot and controller s minds when they decide to guide the aircraft in a certain way. That resulted in a different kind analysis," Erzberger says. As the engineer s idea went from theory to practice, in 2001, NASA demonstrated Direct-To in the airspace of Dallas-Ft. Worth. Estimations based on the demonstration found the technology was capable of saving 900 flying minutes per day for the aircraft in the test area.

  8. A comprehensive framework to quantify energy savings potential from improved operations of commercial building stocks

    International Nuclear Information System (INIS)

    Azar, Elie; Menassa, Carol C.

    2014-01-01

    While studies highlight the significant impact of actions performed by occupants and facility managers on building energy performance, current policies ignore the importance of human actions and the potential energy savings from a more efficient operation of building systems. This is mainly attributed to the lack of methods that evaluate non-technological drivers of energy use for large stocks of commercial buildings to support policy making efforts. Therefore, this study proposes a scientific approach to quantifying the energy savings potential due to improved operations of any stock of commercial buildings. The proposed framework combines energy modeling techniques, studies on human actions in buildings, and surveying and sampling methods. The contributions of this study to energy policy are significant as they reinforce the role of human actions in energy conservation, and support efforts to integrate operation-focused solutions in energy conservation policy frameworks. The framework's capabilities are illustrated in a case study performed on the stock of office buildings in the United States (US). Results indicate a potential 21 percent reduction in the current energy use levels of these buildings through realistic changes in current building operation patterns. - Highlights: • Human actions highly influence energy performance of commercial building stocks. • It is challenging to quantify operation-related energy savings potential. • The proposed framework quantifies potential energy savings from improved operations. • The framework can be applied on any stock of commercial buildings. • Applications include support for operation-focused solutions in energy policies

  9. The application of fuzzy control on energy saving for multi-unit room air-conditioners

    International Nuclear Information System (INIS)

    Chiou, C.B.; Chiou, C.H.; Chu, C.M.; Lin, S.L.

    2009-01-01

    Most research, on energy saving methods for air-conditioners have focused on large chillers as its subject. As most school offices, laboratories, and classrooms are equipped with unitary systems for air-conditioning, this paper discusses methods for energy savings with regard to unitary systems. This paper will put forward the fuzzy temperature control method for multi-unit air-conditioners to enhance energy efficiency. The results show that the use of fuzzy control is efficient for energy saving as well as causing temperature control be steadier, even if there is a change to the thermal loading, the fuzzy control system is able to control the air-conditioning in stable conditions

  10. Material and energy flows in rotary kiln-electric furnace smelting of ferronickel alloy with energy saving

    International Nuclear Information System (INIS)

    Liu, Peng; Li, Baokuan; Cheung, Sherman C.P.; Wu, Wenyuan

    2016-01-01

    Highlights: • Establish the synergy relationship of material and energy in key RKEF processes. • Develop an analysis model to study energy saving with internal cycling of energy. • Analyze material and energy flow parameters and assess its associated synergy effect. • A methodology to evaluate the synergy and design indices of RKEF processes. - Abstract: An energy saving strategy with two energy saving measures has been proposed for reducing energy loss in the rotary kiln-electric furnace (RKEF) for the smelting of ferronickel alloy. One of the measures is to recover the waste heat of exhaust gas from the rotary kiln for preheating and dehydrating the wet laterite ores in the rotary dryer. Another measure is to recycle the furnace gas from the electric furnace into the rotary kiln as fuel. Based on the mass conservation and energy conservation laws, an analysis model of material and energy flows has been developed to understand the potential energy saving with the internal cycling of material and energy in the RKEF process. The analysis model not only considers the energy efficiency but also assess the synergy degree of system. Furthermore, the model also predicts the ratio of raw materials and the energy flow distribution to investigate residual heat and energy and analyze the effects of nickel content on energy flow. Finally, the evaluation methodology of synergy and the technic indices are also presented. Through the investigation of the synergy effect, the performance of the RKEF process can be evaluated and quantified for performance optimization in future.

  11. Energy Saving by Chopping off Peak Demand Using Day Light

    Directory of Open Access Journals (Sweden)

    Ashok Kumar Maitra

    2011-08-01

    Full Text Available An artificial intelligent technique has been implemented in this research using real time datas to calculate how much energy can be chopped from peak load demand. The results are based on real time data that are taken from power delivering centers. These datas do reflect the present condition of power and a solution to those critical conditions during the peak period. These are done in such a way such that helps in judicious scheduling of load. The time based load scheduling has been done so as to understand the basic criteria for solving power crisis during morning peak and early evening peak. The sunray availability and percentage of load that will use day light saving (DLS technique has been taken into account in this work. The results shows that about 0.5% to 1% of load can be shedded off from the peak load period which otherwise is reduction of power. Thus it otherwise also means that an equivalent amount of energy is saved which amounts to a large saving of national money. This result is obtained on monthly and even daily basis. Thus this paper justifies DLS gives a new renewable technique to save energy.

  12. Energy savings potential from improved building controls for the US commercial building sector

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin; Xie, Yulong; Zhao, Mingjie

    2017-09-27

    The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29

  13. Energy Saving Glass Lamination via Selective Radio-Frequency Heating

    Energy Technology Data Exchange (ETDEWEB)

    Shulman, Holly S.; Allan, Shawn M.

    2009-11-11

    This Inventions and Innovations program supported the technical and commercial research and development needed to elevate Ceralink's energy saving process for flat glass lamination from bench scale to a self-supporting technology with significant potential for growth. Radio-frequency heating was any un-explored option for laminating glass prior to this program. With significant commercial success through time and energy savings in the wood, paper, and plastics industries, RF heating was found to have significant promise for the energy intensive glass lamination industry. A major technical goal of the program was to demonstrate RF lamination across a wide range of laminate sizes and materials. This was successfully accomplished, dispelling many skeptics' concerns about the abilities of the technology. Ceralink laminated panels up to 2 ft x 3 ft, with four sets processed simultaneously, in a 3 minute cycle. All major categories of interlayer materials were found to work with RF lamination. In addition to laminating glass, other materials including photovoltaic silicon solar cells, light emitting diodes, metallized glass, plastics (acrylic and polycarbonate), and ceramics (alumina) were found compatible with the RF process. This opens up a wide range of commercial opportunities beyond the initially targeted automotive industry. The dramatic energy savings reported for RF lamination at the bench scale were found to be maintained through the scale up of the process. Even at 2 ft x 3 ft panel sizes, energy savings are estimated to be at least 90% compared to autoclaving or vacuum lamination. With targeted promotion through conference presentations, press releases and internet presence, RF lamination has gained significant attention, drawing large audiences at American Ceramic Society meetings. The commercialization success of the project includes the establishment of a revenue-generating business model for providing process development and demonstrations for

  14. Problems of Technology of Energy-Saving Buildings and Their Impact on Energy Efficiency in Buildings

    Science.gov (United States)

    Kwasnowski, Pawel; Fedorczak-Cisak, Malgorzata; Knap, Katarzyna

    2017-10-01

    Introduction of EPBD in legislation of the EU member states caused that buildings must meet very stringent requirements of thermal protection and energy efficiency. On the basis of EPBD provisions, EU Member States introduce standard of NZEB (Nearly Zero-Energy Buildings). Such activities cause a need for new, innovative materials and technologies, and new approaches to design, construction and retrofitting of buildings. Indispensable is the precise coordination of the design of structure and technical installations of building, which may be provided in an integrated design process in the system BIM. Good coordination and cooperation of all contractors during the construction phase is also necessary. The article presents the problems and the new methodology for the design, construction and use of energy efficient buildings in terms of energy saving technologies, including discussion of the significant impact of the automation of technical installations on the building energy efficiency.

  15. Green Energy in New Construction: Maximize Energy Savings and Minimize Cost

    Science.gov (United States)

    Ventresca, Joseph

    2010-01-01

    People often use the term "green energy" to refer to alternative energy technologies. But green energy doesn't guarantee maximum energy savings at a minimum cost--a common misconception. For school business officials, green energy means getting the lowest energy bills for the lowest construction cost, which translates into maximizing green energy…

  16. Energy at the author's house for saving conventional fuels

    International Nuclear Information System (INIS)

    Nandwani, S.S.

    2006-01-01

    About 20 years ago, we decided to make our house. Being working on the utilization of solar energy and with the objective of saving maximum conventional fuel and some family budget, we dicided to make use of maximum this free and clean fuel. After buying the land with proper orientation, we installed different cheap devices and left the proper provision for another devices to installed in future. At present we solar energy mainly for cooking, water heating for bath and dish washing, drying clothes/fruits/vegetables, purification (pasteurization) of water. In addition. we also use solar cells for some electrical devices like solar radio, solar lamp for emergency, charging batteries and mobile phone etc. For our family of five persons, having 3 coloured TV, 2 computers using many hours of Internet, without any use of fuel other than electricity and sun, our electricity consumption is of the order of 270 (dry/summer)-350 (wet/rainy) kWh/month, depending on the season (US$16-21/month). This is roughly 40-50% of the electricity consumed by my other colleagues who do not use solar energy. With this saving, the initial cost of solar devices (US$1200-1400) is already recovered. In this presentation, construction and results of working of these solar thermal, electrical devices and other energy saving means at our house are mentioned.(Author)

  17. Assessment of Energy-Saving Practices of the Hospitality Industry in Macau

    OpenAIRE

    Xu Wang; NaiQi Wu; Yan Qiao; QingBin Song

    2018-01-01

    Macau is building a world tourism and leisure center. In the context of flourishing hospitality development, energy issues have attracted more and more attention in recent years. On the basis of the field survey of 28 hotels, an evaluation index system is built to assess the status of energy-saving and environmental protection practices in the hospitality industry in Macau. This system is built by selecting some credits from Leadership in Energy and Environmental Design (LEED) and adding seve...

  18. Prices make energy savings more then a slogan

    International Nuclear Information System (INIS)

    Jesny, M.; Hruz, J.

    2003-01-01

    Energy has become a commodity with economic price in Slovakia. For years the energy price has not fulfilled the basic economic criteria - covering of production costs. It was used as one of the instruments of Governments social policy. But the situation is changing. Another phase of bringing the prices to a realistic level brought along a price increase by tens of percents. As the energy prices are increasing and there is a perspective that they will grow further all possible reserves and cheaper energy sources have to be identified. A simplified energetic model of Slovak economy identifies three basic energy-consumer kinds - industry, buildings and transport. Industry uses about one half of the Slovakia's yearly energy-consume. Aim private companies to survive in a competitive environment guarantees of a rational approach towards energy consume. The fact that even in companies that use high volumes of primary raw material the energy consume is the highest cost item (many times higher then the labour costs) is the main incentive for looking for saving possibilities in this area. A decrease of the industries' share in energy consume may indicate some positive trends. The energy consume in industries has dropped by ten percent within ten years and its share on the overall consume is approaching the 45-percent level. This was partially caused by decreasing production volumes or closing down of production in several companies. Energy consume of buildings represents about 35 - 40 percent of the national consume i.e. is on a level similar to other European countries. This is a sector is the most important. It is its structure that is important. Currently there are 1,8 million flat units in Slovakia. Family houses represent 48 percent and the remaining 52 percent go to flats. In close to 800-thousand family houses owned by the people living in them nobody has to stress the importance of energy savings. The user knows exactly how much energy has been used. The ownership is

  19. Energy saving by using natural energy from the shallow ground depths – many years operating results

    Directory of Open Access Journals (Sweden)

    Besler Maciej

    2017-01-01

    Full Text Available We pay back more and more larger attention on solutions which saving energy produced from conventional fuels. This is possible to obtainment in significant quantities in fields in which use up the large quantities of energy. The formation the microclimate of interiors is an example of such situation. Especially in the case air conditioning, heating and mechanical ventilation. There is, however, a possibility of energy saving as well as considerable reducing the pollution coming from combustion of raw materials by utilising the natural renewable energy from the shallow ground. In the paper the results gained during several year of continuous measurement on the exchanger were presented. In summer periods an air cooling occurs 10–12 K, e. g. from +30 °C to +20 °C. In winter on the other hand, a preparatory preheating of the air is possible, e.g. from-18°C to about ± 0°C. It is then possible to obtain for the air conditioning system the total energy needed for cooling purposes at the summer periods, or up to 50% of the ventilation heat energy in winter picks.

  20. Energy saving by using natural energy from the shallow ground depths - many years operating results

    Science.gov (United States)

    Besler, Maciej; Skrzycki, Maciej; Cepiński, Wojciech

    2017-11-01

    We pay back more and more larger attention on solutions which saving energy produced from conventional fuels. This is possible to obtainment in significant quantities in fields in which use up the large quantities of energy. The formation the microclimate of interiors is an example of such situation. Especially in the case air conditioning, heating and mechanical ventilation. There is, however, a possibility of energy saving as well as considerable reducing the pollution coming from combustion of raw materials by utilising the natural renewable energy from the shallow ground. In the paper the results gained during several year of continuous measurement on the exchanger were presented. In summer periods an air cooling occurs 10-12 K, e. g. from +30 °C to +20 °C. In winter on the other hand, a preparatory preheating of the air is possible, e.g. from-18°C to about ± 0°C. It is then possible to obtain for the air conditioning system the total energy needed for cooling purposes at the summer periods, or up to 50% of the ventilation heat energy in winter picks.

  1. Chapter 21: Estimating Net Savings - Common Practices. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Violette, Daniel M. [Navigant, Boulder, CO (United States); Rathbun, Pamela [Tetra Tech, Madison, WI (United States)

    2017-11-02

    This chapter focuses on the methods used to estimate net energy savings in evaluation, measurement, and verification (EM and V) studies for energy efficiency (EE) programs. The chapter provides a definition of net savings, which remains an unsettled topic both within the EE evaluation community and across the broader public policy evaluation community, particularly in the context of attribution of savings to a program. The chapter differs from the measure-specific Uniform Methods Project (UMP) chapters in both its approach and work product. Unlike other UMP resources that provide recommended protocols for determining gross energy savings, this chapter describes and compares the current industry practices for determining net energy savings but does not prescribe methods.

  2. Energy Saving Potential by Utilizing Natural Ventilation under Warm Conditions

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    –airflow simulations of 27 common cases of dwellings (considered as one thermal zone) based on the combination of specific features of the building design, occupancy and climate conditions. The energy saving potential is assessed then by the use of a new assessment method suitable for large-scale scenarios using......The objective of this article is to show the potential of natural ventilation as a passive cooling method within the residential sector of countries which are located in warm conditions using Mexico as a case study. The method is proposed as performing, with a simplified ventilation model, thermal...... the actual number of air-conditioned dwellings distributed among the 27 cases. Thereby, the energy saving is presented as the difference in the cooling demand of the dwelling during one year without and with natural ventilation, respectively. Results indicate that for hot-dry conditions, buildings with high...

  3. Energy saving through trail following in a marine snail.

    Science.gov (United States)

    Davies, Mark S; Blackwell, Janine

    2007-05-07

    Most snails and slugs locomote over a layer of mucus and although the resultant mucus trail is expensive to produce, we show that this expense can be reduced by trail following. When tracking over fresh conspecific trails, the marine intertidal snail Littorina littorea (L.) produced only approximately 27% of the mucus laid by marker snails. When tracking over weathered trails, snails adjusted their mucus production to recreate a convex trail profile of similar shape and thickness to the trail as originally laid. Maximum energy saving occurs when following recently laid trails which are little weathered. Many and diverse ecological roles for trail following have been proposed. Energy saving is the only role that applies across the Gastropoda and so may help to explain why trail following is such a well-established behaviour.

  4. To understand the new world of energy - Energy saving and energy efficiency: the world of energy 2.0

    International Nuclear Information System (INIS)

    Maestroni, Myriam; Chevalier, J.M.; Derdevet, Michel

    2013-01-01

    This bibliographical note contains the table of contents and a brief presentation of a book which proposes a general overview of the world of modern energy, focuses on the main associated political and climatic stakes and challenges. It also addresses the crucial issue of energy efficiency and energy savings which are the pillars of the current energy transition. The chapters address the world energy stakes and challenges, the emergence of a new energetic paradigm, the issues of energy efficiency and energy savings, the main sources of energy savings to be exploited and valorised, the situation in Europe and in the World regarding energy efficiency, the relationship between energy transition and local territories, the necessary continuous innovation

  5. Analyzing the Life Cycle Energy Savings of DOE Supported Buildings Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Hostick, Donna J.; Dirks, James A.; Elliott, Douglas B.

    2009-08-31

    This report examines the factors that would potentially help determine an appropriate analytical timeframe for measuring the U.S. Department of Energy's Building Technology (BT) benefits and presents a summary-level analysis of the life cycle savings for BT’s Commercial Buildings Integration (CBI) R&D program. The energy savings for three hypothetical building designs are projected over a 100-year period using Building Energy Analysis and Modeling System (BEAMS) to illustrate the resulting energy and carbon savings associated with the hypothetical aging buildings. The report identifies the tasks required to develop a long-term analytical and modeling framework, and discusses the potential analytical gains and losses by extending an analysis into the “long-term.”

  6. Computer simulation for optimizing windbreak placement to save energy for heating and cooling buildings

    Science.gov (United States)

    Gordon M. Heisler

    1991-01-01

    Saving energy has recently acquired new importance because of increased concern for dwindling fossil fuel supplies and for the problem of carbon dioxide contributions to global climate change. Many studies have indicated that windbreaks have the ability to save energy for heating buildings. Suggested savings have ranged up 40 percent; though more commonly savings of...

  7. Efficient energy-saving targets for APEC economies

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J.-L. [Institute of Business and Management, National Chiao Tung University, 4F, 114 Chung-Hsiao W. Rd., Sec. 1, Taipei City 100, Taiwan (China)]. E-mail: jinlihu@mail.nctu.edu.tw; Kao, C.-H. [Institute of Business and Management, National Chiao Tung University, 4F, 114 Chung-Hsiao W. Rd., Sec. 1, Taipei City 100, Taiwan (China); Bureau of Energy, Ministry of Economic Affairs, Taiwan (China)

    2007-01-15

    Energy-saving target ratios (ESTR) for 17 APEC economies during 1991-2000 are computed in a total-factor framework. All nominal variables are transformed into real variables by the purchasing power parity (PPP) at the 1995 price level. The data envelopment analysis (DEA) approach is used to find the energy-saving target (EST) for APEC economies without reducing their maximum potential gross domestic productions (GDPs) in each year. Energy, labor, and capital are the three inputs, while GDP is the single output. Our major findings are as follows: (1) China has the largest EST up to almost half of its current usage. (2) Hong Kong, the Philippines, and the United States have the highest energy efficiency. (3) The energy efficiency generally increases for APEC economies except for Canada and New Zealand. (4) Chile, Mexico, and Taiwan have significantly improved their energy efficiency in the last 5 years. (5) An inverted U-shape relation exists between per capita EST and per capita GDP. (6) ESTR has a positive relation with the value-added percentage of GDP of the industry sector and a negative relation with that of the service sector.

  8. Efficient energy-saving targets for APEC economies

    International Nuclear Information System (INIS)

    Hu, J.-L.; Kao, C.-H.

    2007-01-01

    Energy-saving target ratios (ESTR) for 17 APEC economies during 1991-2000 are computed in a total-factor framework. All nominal variables are transformed into real variables by the purchasing power parity (PPP) at the 1995 price level. The data envelopment analysis (DEA) approach is used to find the energy-saving target (EST) for APEC economies without reducing their maximum potential gross domestic productions (GDPs) in each year. Energy, labor, and capital are the three inputs, while GDP is the single output. Our major findings are as follows: (1) China has the largest EST up to almost half of its current usage. (2) Hong Kong, the Philippines, and the United States have the highest energy efficiency. (3) The energy efficiency generally increases for APEC economies except for Canada and New Zealand. (4) Chile, Mexico, and Taiwan have significantly improved their energy efficiency in the last 5 years. (5) An inverted U-shape relation exists between per capita EST and per capita GDP. (6) ESTR has a positive relation with the value-added percentage of GDP of the industry sector and a negative relation with that of the service sector

  9. Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Vossos, Vagelis; Sanstad, Alan; Burch, Gabriel

    2011-10-13

    An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly

  10. Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Grevatt, Jim [Energy Futures Group (United States); Hoffman, Ian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hoffmeyer, Dale [US Department of Energy, Washington, DC (United States)

    2017-07-05

    After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residential savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in

  11. Proceedings of IX International Conference for Renewable Energy, Energy Saving and Energy Education (CIER 2017)

    International Nuclear Information System (INIS)

    2017-01-01

    The Study Centre for Renewable Energy Technologies (CETER) located at the Technological University of Havana Jose Antonio Echeverria (CUJAE) Cuba hosted the IX International Renewable Energy Conference, Energy Saving and Energy Education (CIER 2017). The current focus on Cuba's renewable energy sector is ambitious with the Government proposing to boost investment by USD 3.5 billion in order to reach its goal of generating 24 per cent of its power from renewable energy by 2030. CIER 2017 brought together hundreds of scientist, engineers, manufactures, investors, policy makers, energy users and other specialists from across the entire international renewable energy spectrum to exchange knowledge, debate and analyze the global efforts currently being carried out in the field. This is all with the objective of intensifying the introduction of renewable energy technologies and promoting the sustainable energetic development in Cuba and the Caribe.

  12. Defining The Energy Saving Potential of Architectural Design

    DEFF Research Database (Denmark)

    Naboni, Emanuele; Malcangi, Antonio; Zhang, Yi

    2015-01-01

    Designers, in response to codes or voluntary " green building " programs, are increasingly concerned with building energy demand reduction, but they are not fully aware of the energy saving potential of architectural design. According to literature, building form, construction and material choices...... million different buildings constitute the optimization search space, and the most energy efficient design solutions were explored for 8 different climate zones. The building designs are varied by shape, orientation, window to wall ratio, component and construction types, materials, and different occupant...... results from building energy simulations made with limited computational resources available at the time. The research presented in this paper uses a genetic algorithms based approach for the optimization of heating, cooling and lighting energy demands of different building designs. In total, over 25...

  13. Energy saving by firms. Decision-making, barriers and policies

    International Nuclear Information System (INIS)

    De Groot, H.L.F.; Verhoef, E.T.; Nijkamp, P.

    2001-01-01

    Promoting investments in energy-saving technologies is an important means for achieving environmental goals. Empirical evidence on success conditions of associated policies, however, is scarce. Based on a survey among Dutch firms, this paper sets out to identify the factors that determine the investment behaviour of firms, their attitude towards various types of energy policy, and their responsiveness to changes in environmental policy in the Netherlands. On the basis of discrete choice models, this paper aims to investigate empirically, whether (and how) these strategic features vary over firm characteristics and over sectors

  14. New Energy-Saving Technologies Use Induction Generators

    Science.gov (United States)

    Nola, F.

    1982-01-01

    Two energy-saving technologies tested recently at Marshall Space Flight Center use an induction motor operated in reverse (as an induction generator). In the first, energy ordinarily dissipated during load testing of machinery is recovered and returned to powerline. In the second, efficiency of wind-driven induction generator is improved, and useful range of windspeed is broadened. Both technologies take advantage of ac voltage developed across terminals of an induction motor when rotated at higher than-synchronous speed in the direction it normally turns when power is appled.

  15. Economic aspects of energy saving in greenhouses: physical considerations

    CERN Document Server

    Danloy, L; Gay, J B; Mercier, J A; Reist, A

    1989-01-01

    An important result of experiments carried out over the past six years in a trial greenhouse at CERN (The European Organization for Nuclear Research, Geneva, Switzerland) was the development of a simple and precise method for calculating the energy requirements of a glasshouse; this is valid for any type of greenhouse and climate. An economic study is made using the above method for evaluating the financial effectiveness of various energy-saving methods: double glazing of the side walls, low emissivity glass 'Hortiplus' roofing, soil level heating and a thermal screen.

  16. Energy saving in housing in Syria; Energieeinsparung im Wohnungsbau in Syrien

    Energy Technology Data Exchange (ETDEWEB)

    Hantouch, Yaser

    2009-06-03

    The demand for energy is increasing in Syria annually by 10-11% and the population increases annually 2.54% This growth leads also to increase in the housing,that it is energy-unconscious and consumes many energy. This large increase in energy consumption is an important problem in the housing in Syria, particularly with the lack of observance of various climatic factors,this leads to install the heating or cooling system in all housing in order to improve thermal comfort. The aim of this work is to provide insights into residential buildings with very high energy efficiency. The starting point is the experience from other countries (such as Germany), which have extensive policies, experience and rules for energy-saving buildings. The aim of this work is to provide insights into residential buildings with very high energy efficiency to win. The starting point is the experience from other countries such as Germany, which has extensive policies and rules for energy-saving buildings have. These are transferred with appropriate additions to residential buildings in Syria, and they are specified for special conditions, as well as the economic, social, climatic and regulatory requirements in Syria. There is a new architectural concepts in the design of residential buildings in Syria on their energy issues to research.it was discussed the links between architecture, energy and ecology, concepts of energy-saving building and influencing factors in energy consumption in buildings analyzed and influence of these factors on building and energy in the study area (Syria). This work includes the calculations of energy-efficient building (temperature and energy consumption) for different variants with different simulation programs, and these are assessed socially and economically through interviews, surveys and calculations of Energy Price and the Cost of Buildings. It turns out that there are many opportunities for energy saving in housing in Syria by architectural, design

  17. Energy savings certificates 2011-2013 - Companies. Knowledge for action

    International Nuclear Information System (INIS)

    2013-03-01

    As fossil energy resources are depleted and the environmental impacts of their use are increasingly addressed, energy costs will continue to rise. In this context it is vital for businesses - in the service sector, industry or agriculture - to take steps now to start managing their energy consumption. A number of tools and mechanisms are currently being implemented to help companies in this process, at the national and European levels. Among these, Energy Savings Certificates (ESCs) were introduced in France by the Energy Policy Law of 13 July 2005, with the aim of achieving energy savings in sectors of dispersed activity, mainly buildings, but also light industry, agriculture and transport. For businesses this mechanism is an additional financial leverage tool that can be used to support their energy management projects. Under this scheme energy suppliers must promote energy-efficient investments, and thus are potential sources of financing for project owners. The Grenelle environmental conference forcefully reiterated the need to take action, in particular to renovate existing building stock. In order to achieve the ambitious goals that have been set, the financial mechanisms put into place, including the ESC scheme, must be amplified. Following the first conclusive test period (2006-2009), the ESC scheme is being ramped up during a second and more ambitious three-year period that began on 1 January 2011. The present document is intended to inform companies of changes in the ESC scheme to be implemented for the second period covering 2011-2013. This guidance is divided into two parts: the first section describes the principles of the ESC scheme, and the second offers advice to companies that want to use this scheme for an energy management project. You will also find a practical information sheet listing all the steps to be taken to submit an ESC claim

  18. Assessment of energy savings and of side effects associated with consumption cutoffs. Complete report + abridged version

    International Nuclear Information System (INIS)

    2016-03-01

    As France has been the first European country to implement a legal and regulatory framework which acknowledges the role of cut-off operators, and promotes their direct participation to markets, this report aims at preparing an evolution of this framework, notably by focusing on the notion of energy saving. It highlights the importance of definitions regarding levels of consumption deferment and of energy saving associated with consumption cutoffs. The report first analyses the context: assessment of energy savings associated with consumption cutoffs, discussion of the existence or absence of a typical profile of consumption deferment, and definition of a consumption deferment rate, importance of these works for cut-off integration into the electric power system. It proposes a presentation of the present status of knowledge on energy savings and side effects, defines the energy saving rate, and discusses the sensitivity of this rate to calculation parameters. The next part presents the method adopted to analyse results obtained during experiments. The obtained results are then discussed by distinguishing those obtained in the industrial sector, in the tertiary sector, and in the residential sector. Economic studies are then reported regarding the impact of a wrong choice for the deferment rate on market mechanism rules, and the impact of an explicit taking of the deferment into account. Appendices contain detailed presentations of some specific aspects of these assessments and studies. An abridged version of the report is then provided

  19. Energy Savings and Peak Demand Reduction of a SEER 21 Heat Pump vs. a SEER 13 Heat Pump with Attic and Indoor Duct Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, J.; Withers, C.

    2014-03-01

    This report describes results of experiments that were conducted in an unoccupied 1600 square foot house--the Manufactured Housing (MH Lab) at the Florida Solar Energy Center (FSEC)--to evaluate the delivered performance as well as the relative performance of a SEER 21 variable capacity heat pump versus a SEER 13 heat pump. The performance was evaluated with two different duct systems: a standard attic duct system and an indoor duct system located in a dropped-ceiling space.

  20. Energy efficiency: a source of savings; a priority objective

    International Nuclear Information System (INIS)

    Bethencourt, Anne de; Chorin, Jacky

    2013-01-01

    Energy efficiency is defined as consumption of less energy whilst delivering the same service. Significant progress has been made through the impact of technology, price increases and awareness of waste. Too often viewed as a constraint, energy efficiency nonetheless constitutes the leading potential source of domestic energy for the 2020 goal. Energy efficiency is or will be (depending on the will of the stakeholders, public authorities and society as a whole) a key market for the future and a pathway to creative innovation. Everything is pointing in that direction: the obligation to reduce greenhouse gas emissions fourfold, the new European Directive on Energy Efficiency to be incorporated, the expected increase in energy prices, the presence in France of industry leaders and of a small-scale but important industry in this sector. The goals in energy efficiency entail: - at Community level, that the objective of 20% energy savings for the 2020 goal becomes binding; - at national level, that public policies for energy efficiency are part of a long-term vision, based on the achievements of the Grenelle Environment Forum and avoid sending out any wrong signals which might adversely affect progress. The ESEC proposals are built around the following four themes: - (residential and service sector) buildings: Make energy efficiency into a real sector and a new opportunity 'work together', Optimise tools and regulations, Be innovative in terms of financial support; - fuel poverty; - industry and agriculture; - the particular situation of the overseas departments

  1. Evaluation of energy saving tasks performed by the energy transmission and distribution companies; Denmark; Evaluering af energiselskabernes energibespareaktiviteter

    Energy Technology Data Exchange (ETDEWEB)

    Togeby, M. (Ea Energianalyse A/S, Copenhagen (Denmark))

    2012-05-15

    The evaluation is described in the Agreement of 20 November 2009 between the Danish Climate and Energy Minister and the distribution companies for electricity, natural gas, district heating and oil about the companies' future energy conservation efforts. The evaluation was conducted to provide recommendations for adjusting the system. The results of the evaluation show that energy companies and utilities meet the overall savings obligation. In 2011, 2,098 GWh savings are recorded, which is more than the obligation. The evaluation shows that the net effect is about 760 GWh (36%). When looking at types of energy companies, then the oil companies' activities generally have a low net effect and additionally is assessed to be low in relation to the district heating companies' renovation of the district heating network. The greatest additionally exists among large savings in the industry. The means that energy companies use to achieve savings obligations are significantly different today than a few years ago. Today there are grants for more than 85% of registered savings. Before 2006 primarily information and advice was used. Thus an estimated 400 million DKK annually is used for grants. Socio-economics is positive for the part of the effort that is aimed at businesses. The socio-economic value of the savings is calculated to be twice as large as the total cost when you only look at the industry. The system can thus be readily seen as a useful instrument to promote energy conservation in industry. For households, it is estimated that the net effect is 20% of the reported savings, while for industry the net effect is estimated to be 45%. Also, for renovations of the heat distribution networks the net effect is estimated to be low. (LN)

  2. Water and energy saving at Dutch pastry factory Verkade; Koekjesbakker bespaart water en energie

    Energy Technology Data Exchange (ETDEWEB)

    Van Gool, J. (ed.)

    2003-11-01

    A pastry factory (Verkade in Zaandam, Netherlands) produces 27,000 ton of cookies and biscuits, using 2.2 million m{sup 3} natural gas, 6.7 million kWh and 67,000 m{sup 3} water. By means of new cooling systems a considerable amount of energy and water is saved. [Dutch] Verkade in Zaandam produceert jaarlijks 27.000 ton biscuit, waarvoor 2,2 miljoen m{sup 3} gas, 6,7 miljoen kilowattuur en 67.000 m{sup 3} water nodig is. Dankzij vernieuwde koelsystemen is het water- en energieverbruik flink gedaald.

  3. ESPC Overview. Cash Flows, Scenarios, and Associated Diagrams for Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Tetreault, T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Regenthal, S. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-05-01

    This document is meant to inform state and local decision makers about the process of energy savings performance contracts, and how projected savings and allocated energy-related budgets can be impacted by changes in utility prices.

  4. ESPC Overview: Cash Flows, Scenarios, and Associated Diagrams for Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Tetreault, T.; Regenthal, S.

    2011-05-01

    This document is meant to inform state and local decision makers about the process of energy savings performance contracts, and how projected savings and allocated energy-related budgets can be impacted by changes in utility prices.

  5. Challenges and Opportunities To Achieve 50% Energy Savings in Homes. National Laboratory White Papers

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, Marcus V.A. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-07-01

    This report summarizes the key opportunities, gaps, and barriers identified by researchers from four national laboratories (Lawrence Berkeley National Laboratory, National Renewable Energy Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory) that must be addressed to achieve the longer term 50% saving goal for Building America to ensure coordination with the Building America industry teams who are focusing their research on systems to achieve the near-term 30% savings goal. Although new construction was included, the focus of the effort was on deep energy retrofits of existing homes.

  6. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  7. Year-round daylight saving time will save more energy in India than corresponding DST or time zones

    International Nuclear Information System (INIS)

    Ahuja, Dilip R.; SenGupta, D.P.

    2012-01-01

    Many countries have experimented with daylight saving time (DST) to save energy and to align human activities more closely to the daily cycle of light and darkness. Using a novel methodology, we estimate the year-round energy savings to be obtained from advancing Indian Standard Time (IST), from the introduction of DST, and from dividing the country into two time zones. We find that the option of advancing IST consistently saves more energy than the corresponding DST option, which in turn saves more energy than the corresponding time zones option. This is because the energy benefits of advancing IST accrue for the entire year throughout the country, whereas the benefits of DST are confined to summer months and the benefits of two time zones are largely in the lower energy consuming eastern region. We recommend advancing IST by half-hour to being six hours ahead of UTC. This confers the advantages of DST and time zones without their disadvantages and is forecast to save more than 2 billion kWh of electricity every year during evening peaks that are difficult to supply. While these results are India-specific, similar exercises would be useful to many other countries. - Highlights: ► Advancing IST (YRDST) consistently saves more energy than the corresponding DST. ► DST consistently saves more energy than dividing India into two time zones. ► There are also many non-energy benefits of advancing IST. ► Results are for India; countries with DST may find it useful to consider YRDST.

  8. Development of an Energy-Savings Calculation Methodology for Residential Miscellaneous Electric Loads: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, R.; Eastment, M.

    2006-08-01

    In order to meet whole-house energy savings targets beyond 50% in residential buildings, it will be essential that new technologies and systems approaches be developed to address miscellaneous electric loads (MELs). These MELs are comprised of the small and diverse collection of energy-consuming devices found in homes, including what are commonly known as plug loads (televisions, stereos, microwaves), along with all hard-wired loads that do not fit into other major end-use categories (doorbells, security systems, garage door openers). MELs present special challenges because their purchase and operation are largely under the control of the occupants. If no steps are taken to address MELs, they can constitute 40-50% of the remaining source energy use in homes that achieve 60-70% whole-house energy savings, and this percentage is likely to increase in the future as home electronics become even more sophisticated and their use becomes more widespread. Building America (BA), a U.S. Department of Energy research program that targets 50% energy savings by 2015 and 90% savings by 2025, has begun to identify and develop advanced solutions that can reduce MELs.

  9. Exemplary role of the government in the domain of energy saving

    International Nuclear Information System (INIS)

    2005-09-01

    The objectives of the French energy policy is a progressive reduction of the energy intensity and a progressive abatement of greenhouse gas emissions. In this context, the government administrations wish to show the example with the implementation of exemplary actions in 3 domains: use of low consumption and low pollution vehicles, renovation of administrative buildings and use of low energy consumption equipments (lighting systems, lifts, space heating systems and boilers, windows, appliances and computers), and saving paper. Also, the administrations have to analyze the commercial offers for the purchase of electricity coming from renewable energy sources and for the improvement of the energy efficiency and the mastery of electricity demand. (J.S.)

  10. Energy saving in a deep well pump with splitter blade

    Energy Technology Data Exchange (ETDEWEB)

    Goelcue, Mustafa [Department of Mechanical Education, Pamukkale University, 20017 Kinikli, Denizli (Turkey)]. E-mail: mgolcu@pamukkale.edu.tr; Pancar, Yasar [Department of Mechanical Engineering, Osman Gazi University, 26480 Eskisehir (Turkey); Sekmen, Yakup [Karabuk Vocational Collage, Zonguldak Karaelmas University, 78100 Karabuk (Turkey)

    2006-03-15

    Design parameters, like blade number, blade outlet angle and impeller outlet diameter, affect pump performance and energy consumption. Deep well pumps with splitter blades (DWPwsb) are manufactured to achieve energy saving and improve efficiency. Splitter blades are generally located at the centerline of the main blades. Blade number and blade discharge angle should be conveniently determined when splitter blades are used on the impellers. In this study, impellers having different numbers of blades (z = 5, 6, 7) with and without splitter blades (35%, 60% and 80% of the main blade length) were tested in a deep well pump. Tests have been conducted on a total of 12 impellers, and the characteristics of deep well pumps without splitter blade (DWPwosb) and DWPwsb were obtained experimentally. These results show that splitter blades cause negative effects on pump performance in impellers with blade numbers of 6 and 7. When the splitter blade is added to the impeller with the blade number of 5, the efficiency increases with flow up to 10 l/s flow rate, after which it decreases as the splitter blade length increases. The highest efficiency and the lowest energy consumption were obtained in DWPwsb with 80% of the main blade length. At the best efficiency point (b.e.p), an energy saving of 6.6% and an improvement of 1.14% in efficiency were achieved. An analysis of the additional cost of the splitter blade and the application in an agricultural area were performed.

  11. Energy saving in a deep well pump with splitter blade

    International Nuclear Information System (INIS)

    Goelcue, Mustafa; Pancar, Yasar; Sekmen, Yakup

    2006-01-01

    Design parameters, like blade number, blade outlet angle and impeller outlet diameter, affect pump performance and energy consumption. Deep well pumps with splitter blades (DWPwsb) are manufactured to achieve energy saving and improve efficiency. Splitter blades are generally located at the centerline of the main blades. Blade number and blade discharge angle should be conveniently determined when splitter blades are used on the impellers. In this study, impellers having different numbers of blades (z = 5, 6, 7) with and without splitter blades (35%, 60% and 80% of the main blade length) were tested in a deep well pump. Tests have been conducted on a total of 12 impellers, and the characteristics of deep well pumps without splitter blade (DWPwosb) and DWPwsb were obtained experimentally. These results show that splitter blades cause negative effects on pump performance in impellers with blade numbers of 6 and 7. When the splitter blade is added to the impeller with the blade number of 5, the efficiency increases with flow up to 10 l/s flow rate, after which it decreases as the splitter blade length increases. The highest efficiency and the lowest energy consumption were obtained in DWPwsb with 80% of the main blade length. At the best efficiency point (b.e.p), an energy saving of 6.6% and an improvement of 1.14% in efficiency were achieved. An analysis of the additional cost of the splitter blade and the application in an agricultural area were performed

  12. Energy savings solutions: passive solar design in Iranian cold climate

    Energy Technology Data Exchange (ETDEWEB)

    Nassehzadeh Tabriz, Shahram [Department of Architecture, Miyaneh Branch, Islamic Azad University (Iran, Islamic Republic of)], email: sh_nassehzadeh@m-iau.ac.ir; Mahdavi Tabatabaei Fard, Fariborz [SABAT TARH CO. (Iran, Islamic Republic of)], email: sabat_arc@yahoo.com; Aliyev, Fagan [International Eco-energy Academy (Azerbaijan)], email: ie_academy@yahoo.com

    2011-07-01

    In recent years, there has been a significant increase in the cost of fuel gas, fuel oil and electricity and much thought has been given to the use of solar energy. Living in a solar heated house gives peace of mind and body and it makes good sense in mountainous regions. Severe winters in such regions make more energy for standard living activities in buildings necessary. This paper discusses passive solar building design as an energy saving solution. In this type of design, windows, walls and floors act as storage and distribution devices for solar energy in winter and deflect solar heat in summer. Passive solar design techniques influence the choice of building site, design and materials within the general framework of enriching the quality of life of the inhabitants. As a result, natural resources are saved and the environment is conserved for future generations. In conclusion, it is seen that passive design keeps a home cool and comfortable in summer and warm and cozy in winter with minimal heating and cooling requirements.

  13. Promoting energy-saving and environmentally friendly generation dispatching model in China: Phase development and case studies

    DEFF Research Database (Denmark)

    Ding, Yi; Yang, Hongliang

    2013-01-01

    Energy saving and environmental protection are important conditions for the sustainable development of Chinese economy. However current widely used generation scheduling model based on predefined production quota and tariff results in heavy energy consumption and severe environment pollution. From...... 2007, as concerns over energy shortage and environmental pollution, the Chinese authorities introduced the implementation of energy-saving generation dispatching model, which is an important approach to facilitating energy-saving and reduction of pollutant emission. The objective of implementing energy......-saving generation dispatching model is to prioritize the use of renewable energy resources and new power plants with high efficiency without compromising power system security and reliability. This paper analyzes the necessity and feasibility of implementing energy-efficient and environmentally friendly generation...

  14. Energy Saving: Scaling Network Energy Efficiency Faster than Traffic Growth

    NARCIS (Netherlands)

    Chen, Y.; Blume, O.; Gati, A.; Capone, A.; Wu, C.-E.; Barth, U.; Marzetta, T.; Zhang, H.; Xu, S.

    2013-01-01

    As the mobile traffic is expected to continue its exponential growth in the near future, energy efficiency has gradually become a must criterion for wireless network design. Three fundamental questions need to be answered before the detailed design could be carried out, namely what energy efficiency

  15. Energy Saving Scheme Based On Traffic Forwarding For Optical Fiber Access Networks

    DEFF Research Database (Denmark)

    Lopez, G. Arturo Rodes; Estaran Tolosa, Jose Manuel; Vegas Olmos, Juan José

    2013-01-01

    We report on an energy saving block that regroups and powers off OLTs during low traffic periods, resulting in energy savings up to 87,5% in the central office of optical access networks.......We report on an energy saving block that regroups and powers off OLTs during low traffic periods, resulting in energy savings up to 87,5% in the central office of optical access networks....

  16. Potentials for energy savings and long term energy demand of Croatian households sector

    International Nuclear Information System (INIS)

    Pukšec, Tomislav; Vad Mathiesen, Brian; Duić, Neven

    2013-01-01

    Highlights: ► Long term energy demand of Croatian households sector has been modelled. ► Developed model can describe the whole households sector. ► Main modes include heating, cooling, electrical appliances, cooking and hot water. ► Different scenarios regarding future energy demand are presented and discussed. -- Abstract: Households represent one of the most interesting sectors, when analyzing Croatia’s energy balance. It makes up one of the largest energy consumers with around 75 PJ per year, which is almost 29% of Croatia’s final energy demand. Considering this consumption, implementing various mechanisms, which would lead to improvements in energy efficiency of this sector, seems relevant. In order to plan future energy systems, important would be to know future possibilities and needs regarding energy demand of different sectors. Through this paper, long term energy demand projections of Croatian households sector will be shown. Focus of the paper will be on various mechanisms influencing future energy demand scenarios. Important would be to quantify this influence, whether positive or negative, and see which mechanisms would be the most significant. Energy demand projections in this paper are based upon bottom-up approach model which combines and processes a large number of input data. The model will be compared to Croatian National Energy Strategy and certain differences and conclusions will be presented. One of the major conclusions shown in this paper is significant possibilities for energy efficiency improvements and lower energy demand in the future, based on careful and rational energy planning. Different financial, legal and technological mechanisms can lead to significant savings in the households sector which leads to lower GHG emissions and lower Croatian dependence on foreign fossil fuels.

  17. The unrecognized contribution of renewable energy to Europe's energy savings target

    NARCIS (Netherlands)

    Harmsen, R.; Wesselink, B.; Eichhammer, W.; Worrell, E.

    2011-01-01

    We show that renewable energy contributes to Europe's 2020 primary energy savings target. This contribution, which is to a large extent still unknown and not recognized by policy makers, results from the way renewable energy is dealt with in Europe's energy statistics. We discuss the policy

  18. Analysis on energy saving and emission reduction of clean energy technology in ports

    Science.gov (United States)

    Zhu, Li; Qin, Cuihong; Peng, Chuansheng

    2018-02-01

    This paper discusses the application of clean energy technology in ports. Using Ningbo port Co. Ltd. Beilun second container terminal branch as an example, we analyze the effect of energy saving and emission reduction of CO2 and SO2 by clean energy alternative to fuel oil, and conclude that the application of clean energy technology in the container terminal is mature, and can achieve effect of energy-saving and emission reduction of CO2 and SO2. This paper can provide as a reference for the promotion and application of clean energy in ports.

  19. French people, energy transition, and energy savings. IFOP for Energie Perspective

    International Nuclear Information System (INIS)

    Fourquet, Jerome; Chasles-Parot, Marion

    2014-10-01

    After a presentation of the adopted methodology, this report presents under the form of tables, and comments the results of a survey performed on the perception and relationship French people have on and with energy transition and energy savings. Different aspects have been addressed and assessed by this survey: confidence in local authorities, recognition of energy transition, sensitivity of the issue of energy transition, an example of a local authority communication about energy issues, notoriety of subsidies and primes awarded by the local authority for energy-related works, assessment of well-being in housing, housing occupation status, intention to perform energy-related renovation works in the housing, choice between a large national group or a local company to perform these works

  20. Do LEED-certified buildings save energy? Yes, but...

    Energy Technology Data Exchange (ETDEWEB)

    Newsham, Guy R.; Mancini, Sandra; Birt, Benjamin J. [National Research Council Canada - Institute for Research in Construction, Ottawa (Canada)

    2009-08-15

    We conducted a re-analysis of data supplied by the New Buildings Institute and the US Green Buildings Council on measured energy use data from 100 LEED-certified commercial and institutional buildings. These data were compared to the energy use of the general US commercial building stock. We also examined energy use by LEED certification level, and by energy-related credits achieved in the certification process. On average, LEED buildings used 18-39% less energy per floor area than their conventional counterparts. However, 28-35% of LEED buildings used more energy than their conventional counterparts. Further, the measured energy performance of LEED buildings had little correlation with certification level of the building, or the number of energy credits achieved by the building at design time. Therefore, at a societal level, green buildings can contribute substantial energy savings, but further work needs to be done to define green building rating schemes to ensure more consistent success at the individual building level. Note, these findings should be considered as preliminary, and the analyses should be repeated when longer data histories from a larger sample of green buildings are available. (author)

  1. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Iron and Steel Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Keith Jamison, Caroline Kramer, Sabine Brueske, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. iron and steel manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas and select subareas, representing 82% of sector-wide energy consumption. Energy savings opportunities for individual processes and subareas are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  2. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Pulp and Paper Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. pulp and paper manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas, representing 52% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity

  3. Reported Energy and Cost Savings from the DOE ESPC Program: FY 2014

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Bob S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-03-01

    The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 156 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project. For all 156 projects, there was sufficient information to compare estimated, reported, and guaranteed cost savings. For this group, the total estimated cost savings for the reporting periods addressed were $210.6 million, total reported cost savings were $215.1 million, and total guaranteed cost savings were $204.5 million. This means that on average: ESPC contractors guaranteed 97% of the estimated cost savings; projects reported achieving 102% of the estimated cost savings; and projects reported achieving 105% of the guaranteed cost savings. For 155 of the projects examined, there was sufficient information to compare estimated and reported energy savings. On the basis of site energy, estimated savings for those projects for the previous year totaled 11.938 million MMBtu, and reported savings were 12.138 million MMBtu, 101.7% of the estimated energy savings. On the basis of source energy, total estimated energy savings for the 155 projects were 19.052 million MMBtu, and reported saving were 19.516 million MMBtu, 102.4% of the estimated energy savings.

  4. Energy and Cost Saving of a Photovoltaic-Phase Change Materials (PV-PCM System through Temperature Regulation and Performance Enhancement of Photovoltaics

    Directory of Open Access Journals (Sweden)

    Ahmad Hasan

    2014-03-01

    Full Text Available The current research seeks to maintain high photovoltaic (PV efficiency and increased operating PV life by maintaining them at a lower temperature. Solid-liquid phase change materials (PCM are integrated into PV panels to absorb excess heat by latent heat absorption mechanism and regulate PV temperature. Electrical and thermal energy efficiency analysis of PV-PCM systems is conducted to evaluate their effectiveness in two different climates. Finally costs incurred due to inclusion of PCM into PV system and the resulting benefits are discussed in this paper. The results show that such systems are financially viable in higher temperature and higher solar radiation environment.

  5. Technical Support Document: Development of the Advanced Energy Design Guide for Grocery Stores--50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E. T.; Macumber, D. L.; Long, N. L.; Griffith, B. T.; Benne, K. S.; Pless, S. D.; Torcellini, P. A.

    2008-09-01

    This report provides recommendations that architects, designers, contractors, developers, owners, and lessees of grocery store buildings can use to achieve whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.

  6. CHP systems to save money and cut carbon.

    Science.gov (United States)

    Hopkins, Ian

    2014-10-01

    According to Ian Hopkins, a director of ENER-G Combined Power--which has delivered more than 50 CHP-led energy services contracts within the healthcare sector, having, for the past 30 years, designed and manufactured CHP systems at its global headquarters and R&D centre in Salford--'the energy cost and carbon-saving benefits of combined heat and power are difficult to match where there is a large heating/cooling demand over extended periods'. In this article, he explains how hospitals and other busy healthcare facilities thus 'make ideal bedfellows' for CHP, and outlines the key criteria and considerations, such as sizing, for healthcare engineers, when looking to specify such a system.

  7. Saving energy and protecting environment of electric vehicles

    Science.gov (United States)

    Yuan, Lina; Chen, Huajun; Gong, Jing

    2017-05-01

    With the concept of low carbon economy, saving energy, and protecting environment spread, the development of the electric promotes the research pace of wireless charging electronic vehicles, which will become the best choice of energy supply in the future. To generalize and exploit the corresponding alternative fuels and the research and development, and promotion of electric vehicles, becomes the effective means to directly reduce the consumption of fuel, effectively relieves the problem of nervous energy and environmental pollution, and really conforms to the requirements of the national strategy of sustainable development in China. This paper introduces the status of electronic cars and wireless charging, expounds the principle of wireless charging, and concludes the full text.

  8. Energy saving in refrigeration machinery; Energiebesparing bij koelinstallaties

    Energy Technology Data Exchange (ETDEWEB)

    Kappenberg, B.; Brautigam, F. [DK Kaelteanlagen GmbH, Emsdetten (Germany)

    2009-07-15

    The Germany-based company DK Kaelteanlagen GmbH is specialized in recovering all forms of thermal energy that become available during the operation of refrigeration plants. High efficiency of those plants can be achieved by a smart application of the various DK heat exchangers and storage tanks. This article shows how heat can be generated by the production of cold and how this can lead to a substantial saving in the energy costs of a project. [Dutch] Het Duitse bedrijf DK Kaelteanlagen GmbH heeft zich gespecialiseerd in het terugwinnen van alle vormen van thermische energie die beschikbaar komen tijdens het operationele bedrijf van een koude-installatie. Het slim toepassen van de diverse DK warmtewisselaars voor warmteterugwinning, resulteert in een hogere systeemefficiency van de totate installatie. Aangetoond wordt hoe warmte kan worden geproduceerd door koudeopwekking en hoe daardoor kan worden bespaard op de totale energiekosten van een project.

  9. A practical review of energy saving technology for ageing populations.

    Science.gov (United States)

    Walker, Guy; Taylor, Andrea; Whittet, Craig; Lynn, Craig; Docherty, Catherine; Stephen, Bruce; Owens, Edward; Galloway, Stuart

    2017-07-01

    Fuel poverty is a critical issue for a globally ageing population. Longer heating/cooling requirements combine with declining incomes to create a problem in need of urgent attention. One solution is to deploy technology to help elderly users feel informed about their energy use, and empowered to take steps to make it more cost effective and efficient. This study subjects a broad cross section of energy monitoring and home automation products to a formal ergonomic analysis. A high level task analysis was used to guide a product walk through, and a toolkit approach was used thereafter to drive out further insights. The findings reveal a number of serious usability issues which prevent these products from successfully accessing an important target demographic and associated energy saving and fuel poverty outcomes. Design principles and examples are distilled from the research to enable practitioners to translate the underlying research into high quality design-engineering solutions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Market structure and investor interests frustrate energy savings

    International Nuclear Information System (INIS)

    Van Eck, T.

    2008-01-01

    Major energy savings can be achieved in the Netherlands by bringing demand and supply of heating of cooling closer together and by connecting processes in the correct energetic order. This is already done when one party owns an entire chain, for example in the case of refineries. As soon as several parties are involved, this is seldom achieved. Analysis shows that technical incompetence is seldom an obstacle. Most of the time organizational and economic actors are to blame. Moreover, main influences come from the attitude of the required investors and the position of the government. [mk] [nl

  11. Grant management procedure for energy saving TDM-PONs

    Science.gov (United States)

    Alaelddin, Fuad Yousif Mohammed; Newaz, S. H. Shah; AL-Hazemi, Fawaz; Choi, Jun Kyun

    2018-01-01

    In order to minimize energy consumption in Time Division Multiplexing-Passive Optical Network (TDM-PON), IEEE and ITU-T have mandated sleep mode mechanism for Optical Network Units (ONUs) in the latest TDM-PON standards (e.g. IEEE P1904.1 SIEPON, ITU-T G.sup45). The sleep mode mechanism is a promising mean for maximizing energy saving in an ONU. An ONU in sleep mode flips between sleep and active state depending on the presence or absent of upstream and downstream frames. To ensure Quality of Service (QoS) of upstream frames, the recent TDM-PON standards introduced an early wake-up mechanism, in which an ONU is forced to leave the sleep state on upstream frame arrival. When the Optical Line Terminal (OLT) of a TDM-PON allows early wake-up of its connected ONUs, it allocates gratuitous grants for the sleeping ONUs along with allocating upstream grants for the ONUs in active state. Note that, the gratuitous grants control message sent periodically by the OLT on Inter-Gratuitous grant Interval (IGI) time. After leaving sleep state due to the arrival of upstream frame, the ONU uses its allocated gratuitous grant to send a control message mentioning the amount of upstream bandwidth (upstream grant) required in order to forward the remaining frames in its buffer. However, the existing early wake-up process of ONU can lead to increase the energy consumption of an ONU. It is because of the ONU wakes-up immediately from the sleep state on arrival of the upstream frame, but even so, it needs to wait for forwarding the frame until its allocated gratuitous grant period, resulting in spending energy unnecessarily. In addition, current energy saving solution for TDM-PONs do not provide a clear solution on how to manage different types of grants (e.g. listening grant, upstream transmission grant) within a Dynamic Bandwidth Allocation (DBA) polling cycle. To address this problem, we propose a state-of-art Grant Management Procedure (GMP) in order to maximize energy saving in a TDM

  12. Energy efficiency improvement and cost saving opportunities forpetroleum refineries

    Energy Technology Data Exchange (ETDEWEB)

    Worrell, Ernst; Galitsky, Christina

    2005-02-15

    The petroleum refining industry in the United States is the largest in the world, providing inputs to virtually any economic sector,including the transport sector and the chemical industry. The industry operates 146 refineries (as of January 2004) around the country,employing over 65,000 employees. The refining industry produces a mix of products with a total value exceeding $151 billion. Refineries spend typically 50 percent of cash operating costs (i.e., excluding capital costs and depreciation) on energy, making energy a major cost factor and also an important opportunity for cost reduction. Energy use is also a major source of emissions in the refinery industry making energy efficiency improvement an attractive opportunity to reduce emissions and operating costs. Voluntary government programs aim to assist industry to improve competitiveness through increased energy efficiency and reduced environmental impact. ENERGY STAR (R), a voluntary program managed by the U.S. Environmental Protection Agency, stresses the need for strong and strategic corporate energy management programs. ENERGY STAR provides energy management tools and strategies for successful corporate energy management programs. This Energy Guide describes research conducted to support ENERGY STAR and its work with the petroleum refining industry.This research provides information on potential energy efficiency opportunities for petroleum refineries. This Energy Guide introduces energy efficiency opportunities available for petroleum refineries. It begins with descriptions of the trends, structure, and production of the refining industry and the energy used in the refining and conversion processes. Specific energy savings for each energy efficiency measure based on case studies of plants and references to technical literature are provided. If available, typical payback periods are also listed. The Energy Guide draws upon the experiences with energy efficiency measures of petroleum refineries worldwide

  13. Energy Savers: Tips for Saving Energy and Money at Home

    International Nuclear Information System (INIS)

    Jones, J.

    2000-01-01

    The Department of Energy of the United States of America works to guarantee provisions of safe energy, reliable and economically accessible to support to one developing economy and to protect the atmosphere. These suggestions and ideas to increase the energy efficiency in their house represent simple ways in which our citizens can contribute to preserve the atmosphere at world-wide level, to reduce the level of contamination of the air and to reserve our natural resources for future generations.[Spanish] El Departamento de Energa de los Estados Unidos de America trabaja para garantizar suministros de energa seguros, confiables y econmicamente accesibles para apoyar a una economa en desarrollo y proteger el medio ambiente. Estas sugerencias e ideas para aumentar la eficiencia energetica en su casa representan maneras sencillas en que nuestros ciudadanos pueden contribuir a preservar el medio ambiente a nivel mundial, a reducir el nivel de contaminacin del aire y a reservar nuestros recursos naturales para las generaciones futuras

  14. Key issues in estimating energy and greenhouse gas savings of biofuels: challenges and perspectives

    Directory of Open Access Journals (Sweden)

    Dheeraj Rathore

    2016-06-01

    Full Text Available The increasing demand for biofuels has encouraged the researchers and policy makers worldwide to find sustainable biofuel production systems in accordance with the regional conditions and needs. The sustainability of a biofuel production system includes energy and greenhouse gas (GHG saving along with environmental and social acceptability. Life cycle assessment (LCA is an internationally recognized tool for determining the sustainability of biofuels. LCA includes goal and scope, life cycle inventory, life cycle impact assessment, and interpretation as major steps. LCA results vary significantly, if there are any variations in performing these steps. For instance, biofuel producing feedstocks have different environmental values that lead to different GHG emission savings and energy balances. Similarly, land-use and land-use changes may overestimate biofuel sustainability. This study aims to examine various biofuel production systems for their GHG savings and energy balances, relative to conventional fossil fuels with an ambition to address the challenges and to offer future directions for LCA based biofuel studies. Environmental and social acceptability of biofuel production is the key factor in developing biofuel support policies. Higher GHG emission saving and energy balance of biofuel can be achieved, if biomass yield is high, and ecologically sustainable biomass or non-food biomass is converted into biofuel and used efficiently.

  15. How to tackle energy saving and load leveling. Energy saving towards 2000 and measures for the coming winter (energy-saving activities by California`s SCE, demand side management activities); Sho energy fuka heijunka ni do torikumuka. Seireki 2000 nen ni muketa sho energy to konto no shoene taisaku, Kashu SCE no sho energy (DSM katsudo wo saguru)

    Energy Technology Data Exchange (ETDEWEB)

    Nasu, S. [The Energy Conservation Center Japan, Tokyo (Japan)

    1997-02-01

    Tokyo Electric Power has realized a peak shift of 5% for the maximum power demand by various measures to cope with increasing power demand and differential rate by time zone, including expansion of the differential rate system and heat-storage systems. Some of more notable recent techniques are eco-ice and eco-vendor systems, the former storing ice in the heat-storage tanks and the latter strongly cooling vending machines during nighttime. The NAS battery system is being developed as the new technique for load leveling. The energy-related advisory organ for Minister of International Trade and Industry asks each industrial unit to save at least 1% of power on the annual average as the energy-saving measure towards 2000. The energy-saving measures promoted by the government for the coming winter are controlled release of wastes, efficient use of power, setting room temperature at 19{degree}C or lower and voluntarily refrain from commuting by cars. The US power industry is abandoning the concept of DSM in the midst of deregulation and increased competition, and cutting budgets for new energy development. California`s SCE is promoting energy-saving through expanded use of high-efficiency motors, accurate grasp of customers` needs and publicity activities through internet systems. 4 figs., 1 tab.

  16. New Haven, Connecticut: Targeting Low-Income Household Energy Savings (City Energy: From Data to Decisions)

    Energy Technology Data Exchange (ETDEWEB)

    Strategic Priorities and Impact Analysis Team, Office of Strategic Programs

    2017-11-01

    This fact sheet "New Haven, Connecticut: Targeting Low-Income Household Energy Savings" explains how the City of New Haven used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.

  17. Assessment of Energy-Saving Practices of the Hospitality Industry in Macau

    Directory of Open Access Journals (Sweden)

    Xu Wang

    2018-01-01

    Full Text Available Macau is building a world tourism and leisure center. In the context of flourishing hospitality development, energy issues have attracted more and more attention in recent years. On the basis of the field survey of 28 hotels, an evaluation index system is built to assess the status of energy-saving and environmental protection practices in the hospitality industry in Macau. This system is built by selecting some credits from Leadership in Energy and Environmental Design (LEED and adding several new indices according to the social and economic characteristics of Macau. The results show that the hotels have made significant efforts to improve the energy efficiency in recent years. A total of 71.4% of the hotels have formulated and implemented the energy-saving and environmental protection programs. However, there is an apparent gap in energy and environmental performance between different star-level hotels. The higher is the star-level of a hotel, the higher enthusiasm on energy-saving a hotel has, e.g., 63.6% of the 5-star hotels carried out the carbon auditing and energy management measures, but there is no 2-star hotel that adopted them. The energy-saving performance can be great improved if more efforts are made in the future, especially for the 2-star hotels. Finally, we put forward some suggestions for how to bridge this gap and present a possible roadmap for the further improvement of energy efficiency of the hotel industry in Macau. The results from this work are useful to help the government and hotel managers to take actions for improving the energy utilization and efficiency of the hospitality industry in Macau.

  18. The Resource Mapping Algorithm of Wireless Virtualized Networks for Saving Energy in Ultradense Small Cells

    Directory of Open Access Journals (Sweden)

    Sai Zou

    2015-01-01

    Full Text Available As the current network is designed for peak loads, it results in insufficient resource utilization and energy waste. Virtualized technology makes it possible that intelligent energy perception network could be deployed and resource sharing could become an effective energy saving technology. How to make more small cells into sleeping state for energy saving in ultradense small cell system has become a research hot spot. Based on the mapping feature of virtualized network, a new wireless resource mapping algorithm for saving energy in ultradense small cells has been put forward when wireless resource amount is satisfied in every small cell. First of all, the method divides the virtual cells. Again through the alternate updating between small cell mapping and wireless resource allocation, least amount of small cells is used and other small cells turn into sleeping state on the premise of guaranteeing users’ QoS. Next, the energy consumption of the wireless access system, wireless resource utilization, and the convergence of the proposed algorithm are analyzed in theory. Finally, the simulation results demonstrate that the algorithm can effectively reduce the system energy consumption and required wireless resource amount under the condition of satisfying users’ QoS.

  19. Trimming energy costs. A well-conceived conservation program can provide significant savings for hospitals.

    Science.gov (United States)

    Kluga, T A; Dale, J

    1991-11-01

    Healthcare facilities can realize significant savings on their energy costs if they adopt an effective energy management program. For hospitals beginning such a program, an energy audit is a good first step. Auditors observe and evaluate all energy-using systems and study factors that affect energy use. They then write a report containing on-site observations, an analysis of at least one year's energy bills, and recommendations for low-cost and no-cost energy-reducing measures and capital projects, including new installations and retrofits. Lighting is one area where costs can be cut significantly. During the past few years a revolution in lighting technology has provided many choices for new installation and retrofit. Many utility companies have established rebate programs for certain relamping projects. In addition, integrated heating, ventilating, and air-conditioning systems can present hospitals opportunities to improve patient comfort and energy efficiency. Maintaining and upgrading system boilers and chillers and installing equipment designed to adapt efficiently to changing seasonal needs can generate significant energy savings. Improved energy distribution and control systems should also be a part of a hospital's energy management program.

  20. Wastewater treatment: Self-controlling, frost-free system as a way of saving lots of energy; Selbstregelndes Frostschutzsystem als grosser Energieeinsparer

    Energy Technology Data Exchange (ETDEWEB)

    Haag, J.

    2002-07-01

    This article describes the new heating elements fitted to the tops of the concrete walls of the settlement basin at the wastewater treatment plant in the Swiss mountain resort of Davos. The original system, which featured electrical heating elements cast in the concrete of the basin's walls, was slow to react and its continuous use led to high electricity bills. The article describes the new system, which keeps the tops of the walls ice-free using surface-mounted heating tapes. The reasons for the reduction in energy consumption, which is even lower than predicted, and the self-regulating behaviour of the heating tapes are discussed.

  1. J.R. Simplot: Burner Upgrade Project Improves Performance and Saves Energy at a Large Food Processing Plant

    Energy Technology Data Exchange (ETDEWEB)

    2005-09-01

    This DOE Industrial Program case study describes how the J.R. Simplot Company saved energy and money by increasing the efficiency of the steam system in its potato processing plant in Caldwell, Idaho.

  2. J.R. Simplot: Burner Upgrade Project Improves Performance and Saves Energy at a Large Food Processing Plant (Steam)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2005-09-01

    This DOE Industrial Program case study describes how the J.R. Simplot Company saved energy and money by increasing the efficiency of the steam system in its potato processing plant in Caldwell, Idaho.

  3. Solar thermal technology development: Estimated market size and energy cost savings. Volume 1: Executive summary

    Science.gov (United States)

    Gates, W. R.

    1983-02-01

    Estimated future energy cost savings associated with the development of cost-competitive solar thermal technologies (STT) are discussed. Analysis is restricted to STT in electric applications for 16 high-insolation/high-energy-price states. The fuel price scenarios and three 1990 STT system costs are considered, reflecting uncertainty over future fuel prices and STT cost projections. STT R&D is found to be unacceptably risky for private industry in the absence of federal support. Energy cost savings were projected to range from $0 to $10 billion (1990 values in 1981 dollars), dependng on the system cost and fuel price scenario. Normal R&D investment risks are accentuated because the Organization of Petroleum Exporting Countries (OPEC) cartel can artificially manipulate oil prices and undercut growth of alternative energy sources. Federal participation in STT R&D to help capture the potential benefits of developing cost-competitive STT was found to be in the national interest.

  4. Solar thermal technology development: Estimated market size and energy cost savings. Volume 1: Executive summary

    Science.gov (United States)

    Gates, W. R.

    1983-01-01

    Estimated future energy cost savings associated with the development of cost-competitive solar thermal technologies (STT) are discussed. Analysis is restricted to STT in electric applications for 16 high-insolation/high-energy-price states. The fuel price scenarios and three 1990 STT system costs are considered, reflecting uncertainty over future fuel prices and STT cost projections. STT R&D is found to be unacceptably risky for private industry in the absence of federal support. Energy cost savings were projected to range from $0 to $10 billion (1990 values in 1981 dollars), dependng on the system cost and fuel price scenario. Normal R&D investment risks are accentuated because the Organization of Petroleum Exporting Countries (OPEC) cartel can artificially manipulate oil prices and undercut growth of alternative energy sources. Federal participation in STT R&D to help capture the potential benefits of developing cost-competitive STT was found to be in the national interest.

  5. Overview of Energy Savings and Efficiency Strategies at the Hospitals

    OpenAIRE

    A. Teke; O. Timur

    2014-01-01

    Hospitals represent approximately 6% of total energy consumption in the utility buildings sector. Heating, Ventilation and Air Conditioning (HVAC) systems are the major part of electrical energy consumption at the hospitals. The air-conditioning system is responsible for around 70% of total electricity consumption. Electric motors and lighting systems in a hospital represent approximately 19% and 21% of the total energy consumption, respectively. In this paper, profiles of hospital energy end...

  6. Energy saving and emission reduction of China's urban district heating

    International Nuclear Information System (INIS)

    Chen, Xia; Wang, Li; Tong, Lige; Sun, Shufeng; Yue, Xianfang; Yin, Shaowu; Zheng, Lifang

    2013-01-01

    China's carbon dioxide (CO 2 ) emission ranks highest in the world. China is committed to reduce its CO 2 emission by 40% to 45% from the 2005 levels by 2020. To fulfill the target, China's CO 2 emission reduction must exceed 6995 million tons. Energy consumption and CO 2 emission of China's urban district heating (UDH) are increasing. The current policy implemented to improve UDH focuses on replacing coal with natural gas to reduce energy consumption and CO 2 emission to some extent. This paper proposes that heat pump heating (HPH) could serve as a replacement for UDH to help realize energy-saving and emission-reduction goals to a greater extent. The paper also analyzes the impact of this replacement on the heating and power generation sectors. The results show that replacing coal-based UDH with HPH decreases energy consumption and CO 2 emission by 43% in the heating sector. In the power generation sector, the efficiency of power generation at the valley electricity time increases by 0.512%, and the ratio of peak–valley difference decreases by 16.5%. The decreases in CO 2 emission from the heating and power generation sectors cumulatively account for 5.55% of China's total CO 2 emission reduction target in 2020. - Highlights: ► Replacing urban district heating with heat pump heating. ► Impact of heat pump heating on heating and power generation sectors. ► Potential of energy saving and emission reduction for heat pump heating. ► China should adjust current urban heating strategy

  7. Energy Efficiency Improvement and Cost Saving Opportunities for the Pharmaceutical Industry. An ENERGY STAR Guide for Energy and Plant Managers

    Energy Technology Data Exchange (ETDEWEB)

    Galitsky, Christina; Galitsky, Christina; Chang, Sheng-chieh; Worrell, Ernst; Masanet, Eric

    2008-03-01

    The U.S. pharmaceutical industry consumes almost $1 billion in energy annually. Energy efficiency improvement is an important way to reduce these costs and to increase predictable earnings, especially in times of high energy price volatility. There are a variety of opportunities available at individual plants in the U.S. pharmaceutical industry to reduce energy consumption in a cost-effective manner. This Energy Guide discusses energy efficiency practices and energy efficient technologies that can be implemented at the component, process, system, and organizational levels. A discussion of the trends, structure, and energy consumption characteristics of the U.S. pharmaceutical industry is provided along with a description of the major process steps in the pharmaceutical manufacturing process. Expected savings in energy and energy-related costs are given for many energy efficiency measures, based on case study data from real-world applications in pharmaceutical and related facilities worldwide. Typical measure payback periods and references to further information in the technical literature are also provided, when available. The information in this Energy Guide is intended to help energy and plant managers reduce energy consumption in a cost-effective manner while meeting regulatory requirements and maintaining the quality of products manufactured. At individual plants, further research on the economics of the measures?as well as their applicability to different production practices?is needed to assess potential implementation of selected technologies.

  8. Variable speed drives principles and applications for energy cost savings

    CERN Document Server

    Spitzer, David William

    2014-01-01

    Simply put, a variable speed drive is a controller that allows a motor and its associated equipment to run at different speeds depending upon automated input from an industrial process. That in turn provides the ability to provide smoother operations, and most importantly, energy savings by slowing down machinery when a process does not have to run at full speed. Long a leading book on this technology, this new edition by industry authority David William Spitzer provides insights to improving the applications of variable speed drives. Whether you have basic knowledge or advanced knowledge, you will find this book to be an extremely useful introduction to how variable speed drivers work, how they are best applied, and what to do and what to avoid when employing them as part of an overall automated industrial enterprise, all with an eye on energy savings. Inside, you will find: A basic overview of electrical, hydraulic, and instrumentation principles of variable speed drives. Coverage of the role that variabl...

  9. Hands-on solutions to improve your profits and productivity: Energy-saving tips for small businesses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This booklet leads small business owners to examine the energy consumption of their business and implement significant energy saving modifications and practices. The topics of the booklet include evaluating energy use and suggestions for energy conservation in lighting systems, building envelope and materials, space conditioning, equipment and machines, motors, and vehicles.

  10. Energy saving in heat exchangers of industrial refrigeration systems; Ahorro de energia en intercambiadores de calor en los sistemas de refrigeracion industrial

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, A.; Romero Paredes, Hernando; Ambriz, Juan Jose [Universidad Autonoma Metropolitana-Iztapalapa, Mexico, D. F. (Mexico)

    1994-12-31

    This paper presents the energy losses of the heat exchangers utilized in industrial refrigeration systems . The effects of the different scaling products on the heat transfer rates are presented and the energy not transferred because of them is evaluated. A simplified method for the evaluation is developed and applied to the evaporators and condensers more frequently employed in the industrial refrigeration systems. The internal and external heat transfer coefficients are evaluated in different types of heat exchangers. The energy losses as a function of the scale thickness on the heat exchanger is shown. [Espanol] El trabajo presenta las perdidas energeticas que se tienen en los intercambiadores de calor usados en los sistemas de refrigeracion industrial. Se presentan los efectos que tienen los diferentes incrustantes en las tasas de transferencia de calor y se evalua la energia que no se transfiere causada por aquellos. Se desarrolla un metodo simplificado de evaluacion y se aplica a los evaporadores y condensadores mas comunes empleados en los sistemas de refrigeracion industrial. Se evaluan los coeficientes internos y externos en diferentes tipos de intercambiadores. Se muestran las perdidas energeticas en funcion del espesor del incrustante en la pared del intercambiador.

  11. Retroactive effects of energy-saving lamps; Netzrueckwirkungen von Energiesparlampen

    Energy Technology Data Exchange (ETDEWEB)

    Duerrenberger, G. [Forschungsstiftung Mobilkommunikation c/o ETH Zuerich (Switzerland); Klaus, G. [Maxwave AG, Zuerich (Switzerland)

    2009-11-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at the repercussions on the power supply network that are caused by energy-saving lamps (ESL). These effects result from the operation of the lamps' electronic ballasts which operate at high frequencies. The most noticeable network repercussions that are caused by the rapid current variations in the ESL are discussed, as are ways of considerably reducing them. As for effects on the grid, the authors state that it is not to be expected that any problematic mains feedback will result in practice, particularly not in the well-dimensioned Swiss electricity grid. The methods used in the analysis and the detailed results obtained are presented in tabular and graphical form and discussed.

  12. Considerations for Emerging Markets for Energy Savings Certificates

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, B.; Bird, L.; Barbose, G.

    2008-10-01

    Early experiences with energy savings certificates (ESCs) have revealed both their merit and the challenges associated with them. In the United States, there has been little activity to date, so any lessons must be drawn from experiences in Italy, the United Kingdom (UK), France, and elsewhere. The staying power of European examples, particularly in Italy, demonstrates that ESCs can help initiate more efficiency projects. Although a robust market for renewable energy certificates (RECs) has emerged in both the voluntary and policy compliance contexts in the United States, ESCs have yet to gain significant traction. This report looks at the opportunity presented by ESCs, the unique challenges they bring, a comparison with RECs that can inform expectations about ESC market development, and the solutions and best practices early ESC market experience have demonstrated. It also examines whether there are real market barriers that have kept ESCs from being adopted and what structural features are necessary to develop effective trading programs.

  13. Energy Savings Certificate Markets: Opportunities and Implementation Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, B.; Bird, L.; Barbose, G.

    2009-07-01

    Early experiences with energy savings certificates (ESCs) have revealed their merits and the challenges associated with them. While in the United States ESC markets have yet to gain significant traction, lessons can be drawn from early experiences in the states of Connecticut and New York, as well as from established markets in Italy, France, and elsewhere. The staying power of European examples demonstrates that ESCs can help initiate more efficiency projects. This article compares ESCs with renewable energy certificates (RECs), looks at the unique opportunities and challenges they present, and reviews solutions and best practices demonstrated by early ESC markets. Three major potential ESC market types are also reviewed: compliance, voluntary, and carbon. Additionally, factors that will benefit ESC markets in the United States are examined: new state EEPS policies, public interest in tools to mitigate climate change, and the growing interest in a voluntary market for ESCs.

  14. Study on the energy performance of an energy producing and saving house. Part 3. Measurement results of the connecting system to the power grid and prediction of the PV system electric generation residence in Kyushu; So sho energy seino ni kansuru kenkyu. 3. Gyakuchoryu keito renkei system no nenkan jisseki to Kyushu ni okeru jutaku deno hatsudenryo yosoku

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, O.; Sakai, K.; Hirakawa, M. [Kumamoto University, Kumamoto (Japan). Faculty of Engineering

    1997-11-25

    Two-year study of an energy-producing/-saving house equipped with a 5kWp photovoltaic power generation system is described, in which the track records of this system capable of back-flow and system interconnection and inverter performance are analyzed, and the power expected to be obtained when photovoltaic power generation systems are installed in some residential houses in the Kyushu area is predicted. In the analysis of the yearly variance in the demand/supply of electric power, it turns out that more is generated in spring than in summer, which is thanks to the good weather in spring, typhoons in summer, and power generation efficiency degraded due to temperature rise in the modules. The amount of photovoltaic cell module-generated power is estimated by performing a multiple regression analysis involving the amount of insolation, outside air temperature, and wind speeds. Furthermore, available power is calculated using a relational expression involving inverter performance. On the assumption of 3kW-capacity photovoltaic power generation systems installed at residential houses at various locations across Kyushu, the expected amount of power to be generated is calculated, which proves to be approximately 3000kWh a year, confirming the effectiveness of the photovoltaic power generation system. 6 refs., 9 figs., 3 tabs.

  15. Relationship between people's awareness of environmental capabilities of saving energy, photovoltaic power generation and nuclear power generation

    International Nuclear Information System (INIS)

    Hashiba, Takashi

    2001-01-01

    In this research, relationship between people's awareness of environmental capabilities of saving energy, photovoltaic power generation (PV) and nuclear power generation was investigated using questionnaire method. The results showed that saving energy is conducted without reference to its environment preservation effect. However the older people tend to regard saving energy as contribution to environment preservation. The attitude toward usage of PV has a close relationship to awareness of energy environmental concerns. Acceptance of cost sharing for the introducing of wide-scale PV systems to society is related to environment protection image of PV and the attitude toward loss of social convenience lost as a result of saving energy activities. The older people become, the more priority people put on environment protection before the social convenience. There is little relationship between environmental capabilities of nuclear power generation, that never discharge CO 2 on generation, and awareness of energy environmental concerns. (author)

  16. Measuring the effect of procrastination and environmental awareness on households' energy-saving behaviours: An empirical approach

    International Nuclear Information System (INIS)

    Lillemo, Shuling Chen

    2014-01-01

    A common finding in behavioural economics is that people often procrastinate, i.e., keep postponing planned tasks or decisions that require effort to execute. The effect of procrastination on inter-temporal energy choice behaviours could be even more serious because energy is an abstract, invisible and intangible commodity. This paper uses a web survey to investigate how people's procrastination propensity and environmental awareness affect their heating-energy-saving behaviours. The results indicate that people who state that they have a higher tendency to procrastinate are significantly less likely to have engaged in most of the heating energy-saving activities, especially regarding larger purchases or investments in equipment and the insulation of doors and windows. I also found a positive relationship between environmental awareness and engaging in everyday energy-saving activities such as reducing the indoor temperature. The findings suggest that measures aimed at reducing procrastination are needed to realise energy-saving potential. It is important to find ways to either bring future benefits closer to the present or to magnify the costs of delayed action. For example, one can employ certain feedback systems and commitment devices to make current gains and future costs more visible or tangible. - Highlights: • Norwegian online survey on factors affecting households' heating energy saving activities. • Identify the effect of procrastination and environmental awareness in energy saving decision making. • People with a higher tendency to procrastinate are less likely to engage in energy saving activities. • Procrastination can limit the positive effect of environmental awareness on energy saving. • Innovative behavioural measures are suggested to bring people's “energy saving plans or decisions” to action

  17. Energy consumption and energy saving : their evolution in Spain and other countries

    International Nuclear Information System (INIS)

    Serrano Martinez, F.

    1995-01-01

    The article shows the development of energy consumption since the seventies in three main energy consuming sectors: industry, residential services and transport. While the energy intensity and consumption in the industrial sector have considerably decreased- taking 100 as index in 1973, this was 68 in 1988-in the other sectors, the increase of comfort in houses and business offices, as well as the number or automobiles, have made consumption in these sectors increase despite the efforts made in the improvement of return of installations and reduction of cars consumption. In the industry, large energy savings coincide with remarkable technological innovations and for the future, the achieved savings and future trends, as well as conditions for the energy saving, are analyzed for the rest of the sectors. (Author)

  18. 76 FR 2029 - Small Business Investment Companies-Energy Saving Qualified Investments

    Science.gov (United States)

    2011-01-12

    .... Section by Section Analysis Section 107.50--Definitions. The Energy Act provides that energy saving... Sec. 107.50. ``Energy Saving Qualified Investment'' The proposed regulatory definition of Energy... definition. SBA believes that reference wherever possible to existing standards for energy efficient products...

  19. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stern, Frank [Navigant, Boulder, CO (United States); Spencer, Justin [Navigant, Boulder, CO (United States)

    2017-10-03

    Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

  20. Information technology applications in improving energy saving; IT-sovellukset ja energiatehokkuuden kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M.; Heine, P.; Kallonen, M. (and others)

    2007-07-01

    Energy saving is becoming more and more important issue among the many actors within the strongly developing energy field. The hourly kWh-metering represents a new step in the electrical field - the number of the hourly kWh-metered customer points is increasing rapidly and the amount of the detailed data is huge. This also enables new approaches to find energy saving potentials. This project focuses to find energy saving potentials especially in households and office buildings. In this project, the hourly-metered energy data is linked with specific customer data to identify the energy saving potential and further developing products to make the energy use more efficient. (orig.)

  1. Managing Your Energy: An ENERGY STAR(R) Guide for Identifying Energy Savings in Manufacturing Plants

    Energy Technology Data Exchange (ETDEWEB)

    Worrell, Ernst; Angelini, Tana; Masanet, Eric

    2010-07-27

    In the United States, industry spends over $100 billion annually to power its manufacturing plants. Companies also spend on maintenance, capital outlay, and energy services. Improving energy efficiency is vital to reduce these costs and increase earnings. Many cost-effective opportunities to reduce energy consumption are available, and this Energy Guide discusses energy-efficiency practices and energy-efficient technologies that can be applied over a broad spectrum of companies. Strategies in the guide address hot water and steam, compressed air, pumps, motors, fans, lighting, refrigeration, and heating, ventilation, and air conditioning. This guide includes descriptions of expected energy and cost savings, based on real-world applications, typical payback periods, and references to more detailed information. The information in this Energy Guide is intended to help energy and plant managers achieve cost-effective energy reductions while maintaining product quality. Further research on the economics of all measures--as well as on their applicability to different production practices?is needed to assess their cost effectiveness at individual plants.

  2. Potential electricity savings by variable speed control of compressor for air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nasution, Henry [Bung Hatta University, Department of Mechanical Engineering, Faculty of Industrial Engineering, Padang, West Sumatera (Indonesia); Wan Hassan, Mat Nawi [Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, Skudai, Johor Bahru-Darul Ta' zim (Malaysia)

    2006-05-15

    The potential of a variable-speed compressor running on a controller to provide enhanced load-matching capability, energy saving and thermal comfort for application in air-conditioning system is demonstrated. An air-conditioning system, originally operated on a constant speed mode, is retrofitted with an inverter and a PID controller. The system was installed to a thermal environmental room together with a data acquisition system to monitor energy consumption and temperature of the room. Measurements were taken 2 h daily at a time interval of 5 min for an on/off and an inverter variable-speed conditions. The results indicate that thermal comfort of the room together with energy saving can be obtained through a proper selection of K for the controller. At a temperature setting of 22 C, the energy saving for the system is estimated to reach 25.3% for PID controllers. (orig.)

  3. Carbon and energy saving markets in compressed air

    Science.gov (United States)

    Cipollone, R.

    2015-08-01

    CO2 reduction and fossil fuel saving represent two of the cornerstones of the environmental commitments of all the countries of the world. The first engagement is of a medium to long term type, and unequivocally calls for a new energetic era. The second delays in time the fossil fuel technologies to favour an energetic transition. In order to sustain the two efforts, new immaterial markets have been established in almost all the countries of the world, whose exchanges (purchases and sales) concern CO2 emissions and equivalent fossil fuels that have not been emitted or burned. This paper goes deep inside two aspects not yet exploited: specific CO2 emissions and equivalent fossil fuel burned, as a function of compressed air produced. Reference is made to the current compressor technology, carefully analysing CAGI's (Compressed Air Gas Institute) data and integrating it with the PNUEROP (European Association of manufacturers of compressors, vacuum pumps, pneumatic tools and allied equipment) contribution on the compressor European market. On the base of energy saving estimates that could be put in place, this article also estimates the financial value of the CO2 emissions and fossil fuels avoided.

  4. Energy-saving belt conveyors installed in Polish collieries

    Directory of Open Access Journals (Sweden)

    Jerzy ANTONIAK

    2010-01-01

    Full Text Available An important problem of reducing energy consumption and dioxide emissions in the stage of construction and operation of mine belt conveyors is connected with their broad use in the industry. However, this notion is related to a reduction of electric energy consumption for conveyor drive and for production of conveyor components and assemblies (belts, rollers, load-bearing structure etc.. An essential role is played by an increased life of belt conveyors assemblies and components, principally belts. A reduced electric energy consumption results in a decreased CO2 emissions, e.g. hard coal – fired power station issues 0.28 kg CO2 per production of 1 kWh, in to answer production of 1 t steel accounts for 3.2 t CO2 emissions. The subject-matter presented in the paper concerning energy-saving in the horizontally and inclined mine belt conveyors installed in a Polish colliery – Anna, Jankowice and Marcel, has a big economic significance and it is important from the point of view of environmental protection.

  5. Quantifying Adoption Rates and Energy Savings Over Time for Advanced Manufacturing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Hanes, Rebecca [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Carpenter Petri, Alberta C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Riddle, Matt [Argonne National Laboratory; Graziano, Diane [Argonne National Laboratory

    2017-10-09

    and used to identify the technologies which offer the greatest cumulative sector-level energy savings over a period of 20 years. Preliminary analysis indicates that relatively simple technologies, such as efficient furnaces, will be adopted more quickly and result in greater cumulative energy savings compared to more complex technologies that require process retrofitting, such as advanced control systems.

  6. TRIAD AND MODUS MODEL REALIZATION OF POTENTIAL ENERGY AND RESOURCE SAVINGS ON THE ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Maryna Klimchuk

    2017-03-01

    Full Text Available The article studied categories of the resource, energy and potential energy savings that resulted in the development of triad and modus model of potential energy and resource savings enterprises based on the concept of “environmental economics”. To assess the level of energy efficiency in the company it is proposed to use a definition of “potential of energy and resource savings” which is interpreted as a synergistic approach to improve energy conservation reserves through intensification of production based on the rationalization of the use of all resources. Keywords: potential of energy savings, renewable energy, energy efficiency, environmental economics, energy resource.

  7. Evaluation of energy and cost savings in mobile Cloud RAN

    DEFF Research Database (Denmark)

    Checko, Aleksandra; Christiansen, Henrik Lehrmann; Berger, Michael Stübert

    2013-01-01

    , is sub optimal, comparing to a novel, cloud based architecture called Cloud Radio Access Network (C-RAN). In C-RAN a group of cells shares processing resources, and hence benefit from statistical multiplexing gain is expected. In this paper, the energy and cost savings in C-RAN are evaluated numerically......The load in mobile networks is subject to variations during the day, due to user mobility and varying network average usage. Therefore, the traditional or Distributed Radio Access Network (D-RAN) architecture, where the BaseBand processing Units (BBUs) are assigned statically to a number of cells...... using OPNET Modeler. A real case scenario is built upon the mobile traffic forecast for year 2017, a number of recommendations on traffic models and a proposed C-RAN implementation. The results achieved show that the maximum statistical multiplexing gain for user plane traffic in C-RAN architecture is 4...

  8. The daylight alternative for energy conservation saving in lighting systems; La luz natural alternativa para el ahorro de energia en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Escutia Perez, A.; Cruz Mendez, E. P. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico D. F. (Mexico); Buitron Sanchez, H. [Programa de Ahorro de Energia del Sector Electrico, Mexico D. F. (Mexico)

    1995-12-31

    The technological advances generate far reaching changes in all types of installation. The new spaces and the existing ones justify the introduction of new technologies taking into account important economic considerations, mostly when the advantage of daylight is taken into consideration in industrial and commercial lighting. In the daylight design it is necessary to know the solar transit, the atmospheric conditions, the architectural design of the building, the materials and the control elements, etc. to apply with precision the calculation method. The fundamental lighting technic have varied little. In the greatest part of commerces and industries the general lighting is used, that produces an illumination more or less uniform on the working areas, which guarantees a total freedom for the placement of machinery, working benches, racks, exhibitors, clothes racks, etc.. This type of lighting is obtained by means of the use of a more or less regular series of skylights. The adequate localized lighting is used in those zones where because of the presence of obstructions or unfavorable slant of the working plan are not sufficiently well lighted by the general lighting system. The daylight use in accordance with the every moment availability will permit in many working centers a sensible diminution of the artificial lighting time, provided that the characteristics of the control operation of the installation permit it, along with modern controlling devices and the great variety of efficient saving lamps. [Espanol] Los avances tecnologicos generan cambios trascendentes en todo tipo de instalacion. Los nuevos espacios y los ya existentes justifican la introduccion de nuevas tecnologias teniendo consideraciones economicas importantes, sobre todo cuando se aprovecha la luz natural en sistemas de alumbrado industrial y comercial. En el diseno de iluminacion natural, es necesario tener el conocimiento del transito solar, las condiciones atmosfericas, el diseno

  9. Business Model for Femtocells: Franchising for Energy Saving

    Directory of Open Access Journals (Sweden)

    Jonathan Rodriguez

    2011-12-01

    Full Text Available Purpose—The purpose of the paper is to analyze how business models are employed in mobile communications, in order to tune them to the Femtocell domain, in addition to studying other goals that can be achieved by looking at the business models in an alternative way.Design/methodology/approach—By analyzing the technologies directly linked to a business model, it would be possible to produce a taxonomy of their usage. An analysis of the value chain is used to understand how to enhance current approaches to achieve new goals.Findings—The article covers the perspective that mobile networks evolution and femtocell implementation in the mobile market can bring innovative services to the final user, by leveraging on alternative usage of business models.Research limitations/implications—The acceptance of the usage of particular business models by mobile operators can bring benefits to the final users in the form of innovative services. An example of these services is the implementation of techniques to save energy on the terminal side.Practical implications—As soon as the targeted technologies become mature, it will be possible to provide novel services to the final user, while increasing the operational and business benefits of the mobile operators.Originality/Value—A novel view on the current application of the business model is developed, and new innovative goals are shown to be achievable by novel approaches, or by traditional approaches applied in an innovative way. In particular, we show a case study where a novel service called C2POWER applies franchising (re-selling of services of broadband access, to save energy on the mobile terminal side.

  10. Business Model for Femtocells: Franchising for Energy Saving

    Directory of Open Access Journals (Sweden)

    Tiago Carvalho Moreira

    2013-08-01

    Full Text Available Purpose—The purpose of the paper is to analyze how business models are employed in mobile communications, in order to tune them to the Femtocell domain, in addition to studying other goals that can be achieved by looking at the business models in an alternative way. Design/methodology/approach—By analyzing the technologies directly linked to a business model, it would be possible to produce a taxonomy of their usage. An analysis of the value chain is used to understand how to enhance current approaches to achieve new goals. Findings—The article covers the perspective that mobile networks evolution and femtocell implementation in the mobile market can bring innovative services to the final user, by leveraging on alternative usage of business models. Research limitations/implications—The acceptance of the usage of particular business models by mobile operators can bring benefits to the final users in the form of innovative services. An example of these services is the implementation of techniques to save energy on the terminal side. Practical implications—As soon as the targeted technologies become mature, it will be possible to provide novel services to the final user, while increasing the operational and business benefits of the mobile operators. Originality/Value—A novel view on the current application of the business model is developed, and new innovative goals are shown to be achievable by novel approaches, or by traditional approaches applied in an innovative way. In particular, we show a case study where a novel service called C2POWER applies franchising (re-selling of services of broadband access, to save energy on the mobile terminal side.

  11. An Experimental Study of Energy-Saving Shoes for Robot as Sagittal Plane Assistance

    Science.gov (United States)

    Minakata, Hideaki; Tadakuma, Susumu

    In this paper, we propose flexible shoe system to apply passive walking manner to ordinary humanoid biped. In this system, 2DOF (FF & FB) control scheme is used and realize walking with less ankle torque. Besides, this system is consisted as reference modification of position control system, so it can be applicable to most of walking robot even if its joint servo is black box. The effectiveness and characteristics of this system is confirmed by computer simulations and experimental result. The softness of shoe is very important parameter for energy consumption and walking stability. From the discussions of the system, it is said that sagittal plane assistance shoes reduce the energy loss due to the ankle joint friction. Finally, we confirmed the reduction of energy consumption on walking experiment, so we call this system as “energy saving shoes.”

  12. Energy Saving Melting and Revert Reduction Technology (E-SMARRT): Development of Surface Engineered Coating Systems for Aluminum Pressure Die Casting Dies: Towards a 'Smart' Die Coating

    Energy Technology Data Exchange (ETDEWEB)

    Dr. John J. Moore; Dr. Jianliang Lin,

    2012-07-31

    The main objective of this research program was to design and develop an optimal coating system that extends die life by minimizing premature die failure. In high-pressure aluminum die-casting, the die, core pins and inserts must withstand severe processing conditions. Many of the dies and tools in the industry are being coated to improve wear-resistance and decrease down-time for maintenance. However, thermal fatigue in metal itself can still be a major problem, especially since it often leads to catastrophic failure (i.e. die breakage) as opposed to a wear-based failure (parts begin to go out of tolerance). Tooling costs remain the largest portion of production costs for many of these parts, so the ability prevent catastrophic failures would be transformative for the manufacturing industry.The technology offers energy savings through reduced energy use in the die casting process from several factors, including increased life of the tools and dies, reuse of the dies and die components, reduction/elimination of lubricants, and reduced machine down time, and reduction of Al solder sticking on the die. The use of the optimized die coating system will also reduce environmental wastes and scrap parts. Current (2012) annual energy saving estimates, based on initial dissemination to the casting industry in 2010 and market penetration of 80% by 2020, is 3.1 trillion BTU's/year. The average annual estimate of CO2 reduction per year through 2020 is 0.63 Million Metric Tons of Carbon Equivalent (MM TCE).

  13. A Method for Estimating Potential Energy and Cost Savings for Cooling Existing Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    Van Geet, Otto

    2017-04-24

    NREL has developed a methodology to prioritize which data center cooling systems could be upgraded for better efficiency based on estimated cost savings and economics. The best efficiency results are in cool or dry climates where 'free' economizer or evaporative cooling can provide most of the data center cooling. Locations with a high cost of energy and facilities with high power usage effectiveness (PUE) are also good candidates for data center cooling system upgrades. In one case study of a major cable provider's data centers, most of the sites studied had opportunities for cost-effective cooling system upgrades with payback period of 5 years or less. If the cable provider invested in all opportunities for upgrades with payback periods of less than 15 years, it could save 27% on annual energy costs.

  14. MUXER—A New Equipment for Energy Saving in Ethernet

    Directory of Open Access Journals (Sweden)

    Md Mehedi Hassan Onik

    2017-11-01

    Full Text Available Nowadays, the rapidly increasing energy consumption of communication equipment is an economic and environmental problem that needs to be addressed. Small Local Area Networks (LAN switches in the US alone consume about 8 TWh per year that corresponds to hundreds of millions of US dollars in electricity. A main reason is communication equipment, due to the fact that, Ethernet switches have to active all days even in low-traffic time. There are many approaches to make the switches sensitive with the different traffic load environment, but they have to put some changes to current Ethernet that cause the incompatibility issues. This paper proposes a new device called Modified Multiplexer (MUXER, which can control the power functions of switches without modifying the current Ethernet protocol. The MUXER devices are put before the switches in the network, which provide some functions to transfer incoming Media Access Control (MAC data frames to the corresponding switches managed by MUXERs. By using the proposed device, the wasted energies in the network can be reduced, especially in the specified low-traffic time. We describe the result of numerical analysis and compare detail power consumption data between a normal and a network where MUXERs are installed. In this work, the explained result shows that if a network administrator can estimate the number of MUXER needed for a particular network and install accordingly, our device can provides a significant energy saving.

  15. Dividing wall column: Improving thermal efficiency, energy savings and economic performance

    International Nuclear Information System (INIS)

    Aurangzeb, Md; Jana, Amiya K.

    2016-01-01

    Highlights: • A rigorous model is developed for a dividing wall column. • Heat transfer model for metal wall is proposed. • Performance improvement is quantified for a ternary system. • Thermal efficiency, energy savings and cost are three used indices. - Abstract: This work aims at investigating the performance improvement of a dividing wall column (DWC) for the separation of a ternary system. It is true that for fractionating a ternary mixture, at least a sequence of two conventional distillation columns is required. To improve energetic and economic potential, and reduce space requirement, two columns are proposed to merge into one shell with a dividing wall. For developing the mathematical model of a distillation column, we consider the effect of heat transfer through the metal wall placed at an intermediated position inside the cylindrical column. The simulated DWC model is verified using the Aspen Plus flowsheet simulator with a wide variety of phase equilibrium models. The superiority of this proposed heat integrated configuration is shown for a ternary hydrocarbon system over a conventional distillation sequence (CDS) in terms of mainly three performance indexes, namely thermal efficiency, energy savings and total annual cost (TAC). It is investigated that the dividing wall distillation scheme can secure a 37.5% energy efficiency, and a 22.6% savings in energy consumption and 23.23% in TAC. The promising performance can also be quantified in terms of a reasonably low payback period of 2.11 years.

  16. Social Optimization and Pricing Policy in Cognitive Radio Networks with an Energy Saving Strategy

    Directory of Open Access Journals (Sweden)

    Shunfu Jin

    2016-01-01

    Full Text Available The rapid growth of wireless application results in an increase in demand for spectrum resource and communication energy. In this paper, we firstly introduce a novel energy saving strategy in cognitive radio networks (CRNs and then propose an appropriate pricing policy for secondary user (SU packets. We analyze the behavior of data packets in a discrete-time single-server priority queue under multiple-vacation discipline. With the help of a Quasi-Birth-Death (QBD process model, we obtain the joint distribution for the number of SU packets and the state of base station (BS via the Matrix-Geometric Solution method. We assess the average latency of SU packets and the energy saving ratio of system. According to a natural reward-cost structure, we study the individually optimal behavior and the socially optimal behavior of the energy saving strategy and use an optimization algorithm based on standard particle swarm optimization (SPSO method to search the socially optimal arrival rate of SU packets. By comparing the individually optimal behavior and the socially optimal behavior, we impose an appropriate admission fee to SU packets. Finally, we present numerical results to show the impacts of system parameters on the system performance and the pricing policy.

  17. Example for electrical energy savings with the pump adjustable electric drive

    International Nuclear Information System (INIS)

    Mirchevski, Slobodan; Andonov, Zdravko; Saracevic, Fahrudin; Micevski, Darko; Buchkoski, Aleksandar

    2004-01-01

    Most used method of flow regulation is by throttling the pipeline. Development of power electronic gives opportunity for induction motor pump drives speed control. The common ways of pump flow control are throttling, reducing the working circle, usage of fore circle shovels rotating, by pass and pump speed control Only pump speed control is the most suitable for the energy possibilities. Intensive development of power electronic gives. opportunity to create devices - power converters, which can change the speed of induction motor. For that improvement the energy savings the measurements of power consumption with throttling and speed control have been made. Also, the MATLAB-SIMULINK model of the measured system has been made. The economic effects of saving energy using adjustable speed drives are analyzed for the measured values. The analysis shows that the money payback period of speed controller investment is short compared with the drive lifetime (20 years). (Author)

  18. Energy-saving analysis of hydraulic hybrid excavator based on common pressure rail.

    Science.gov (United States)

    Shen, Wei; Jiang, Jihai; Su, Xiaoyu; Karimi, Hamid Reza

    2013-01-01

    Energy-saving research of excavators is becoming one hot topic due to the increasing energy crisis and environmental deterioration recently. Hydraulic hybrid excavator based on common pressure rail (HHEC) provides an alternative with electric hybrid excavator because it has high power density and environment friendly and easy to modify based on the existing manufacture process. This paper is focused on the fuel consumption of HHEC and the actuator dynamic response to assure that the new system can save energy without sacrificing performance. Firstly, we introduce the basic principle of HHEC; then, the sizing process is presented; furthermore, the modeling period which combined mathematical analysis and experiment identification is listed. Finally, simulation results show that HHEC has a fast dynamic response which can be accepted in engineering and the fuel consumption can be reduced 21% to compare the original LS excavator and even 32% after adopting another smaller engine.

  19. Energy-Saving Analysis of Hydraulic Hybrid Excavator Based on Common Pressure Rail

    Science.gov (United States)

    Jiang, Jihai; Su, Xiaoyu

    2013-01-01

    Energy-saving research of excavators is becoming one hot topic due to the increasing energy crisis and environmental deterioration recently. Hydraulic hybrid excavator based on common pressure rail (HHEC) provides an alternative with electric hybrid excavator because it has high power density and environment friendly and easy to modify based on the existing manufacture process. This paper is focused on the fuel consumption of HHEC and the actuator dynamic response to assure that the new system can save energy without sacrificing performance. Firstly, we introduce the basic principle of HHEC; then, the sizing process is presented; furthermore, the modeling period which combined mathematical analysis and experiment identification is listed. Finally, simulation results show that HHEC has a fast dynamic response which can be accepted in engineering and the fuel consumption can be reduced 21% to compare the original LS excavator and even 32% after adopting another smaller engine. PMID:24194683

  20. International Performance Measurement and Verification Protocol: Concepts and Options for Determining Energy and Water Savings, Volume I (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    2002-03-01

    This protocol serves as a framework to determine energy and water savings resulting from the implementation of an energy efficiency program. It is also intended to help monitor the performance of renewable energy systems and to enhance indoor environmental quality in buildings.

  1. ENERGY SAVING AT OPERATION OF OUTDOOR SWIMMING POOLS

    Directory of Open Access Journals (Sweden)

    V. F. Ivin

    2013-09-01

    Full Text Available Purpose. Energy saving is a major problem in modern power engineering and various energy-consuming devices. They include outdoor swimming pools. In order to maintain them in working condition, especially in winter period, it takes significant amount of thermal energy. Task of heat loss substantial decrease in open swimming pools is considered in the article (on DNURT example. Methodology. The method of determining the mass and heat loss on the basis of criteria equations of heat and mass transfer theory is used. Findings. Calculations of the actual DNURT pool heat loss for different seasons, as for natural convection both for air forced motion above the free water surface are performed. It is shown that for the adiabatic evaporation conditions of water from the pool in winter during blow-off with wind the heat loss can be up to 2 kW/m2 on surface. To reduce these losses it is offered to cover water surface in a pool with a special material with low thermal conductivity on the basis of porous polyethylene during the time when the pool is not used for other purposes. It is shown that the implementation of these standards will reduce the actual heat loss, at least 5-6 times. Originality. The solution of important environmental and energy problem thanks to reducing heat losses by the pool in different times of a year and correspondingly lower emissions of power generating enterprises. Practical value. It is shown that the coating surface of the pool with poorly heat-conducting and easy to install coating will let, at a minimum, to reduce the actual heat loss on 5-6 times and reduce the emissions of power plants generating energy for pool heating.

  2. A New Method to Energy Saving in a Micro Grid

    Directory of Open Access Journals (Sweden)

    Andrea Vallati

    2015-10-01

    Full Text Available Optimization of energy production systems is a relevant issue that must be considered in order to follow the fossil fuels consumption reduction policies and CO2 emission regulation. Increasing electricity production from renewable resources (e.g., photovoltaic systems and wind farms is desirable but its unpredictability is a cause of problems for the main grid stability. A system with multiple energy sources represents an efficient solution, by realizing an interface among renewable energy sources, energy storage systems, and conventional power generators. Direct consequences of multi-energy systems are a wider energy flexibility and benefits for the electric grid, the purpose of this paper is to propose the best technology combination for electricity generation from a mix of renewable energy resources to satisfy the electrical needs. The paper identifies the optimal off-grid option and compares this with conventional grid extension, through the use of HOMER software. The solution obtained shows that a hybrid combination of renewable energy generators at an off-grid location can be a cost-effective alternative to grid extension and it is sustainable, techno-economically viable, and environmentally sound. The results show how this innovative energetic approach can provide a cost reduction in power supply and energy fees of 40% and 25%, respectively, and CO2 emission decrease attained around 18%. Furthermore, the multi-energy system taken as the case study has been optimized through the utilization of three different type of energy storage (Pb-Ac batteries, flywheels, and micro—Compressed Air Energy Storage (C.A.E.S..

  3. Development of the Advanced Energy Design Guide for K-12 Schools -- 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Leach, M.; Pless, S.; Torcellini, P.

    2013-02-01

    This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-K12) (ASHRAE et al. 2011a). The AEDG-K12 provides recommendations for achieving 50% whole-building energy savings in K-12 schools over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-K12 was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy (DOE).

  4. Qualitative assessment of the CEE arrangement - Second period 2011-2013. The Certificates of Energy Savings: an arrangement which catalyses decision by households for energy saving works. Synthesis

    International Nuclear Information System (INIS)

    2013-04-01

    After previous assessments on energy savings, costs, and potentials, this publication reports a qualitative assessment of the CEE arrangement (certificate of energy savings). The objective is to get a better insight into decision making by the final consumer. After a brief presentation of the survey methodology, the report describes the CEEs as a catalyst for higher performance works. The survey highlighted the incentive effect of the CEE premium, and the lever effect of advice and information. The report also outlines that the CEE is an additional tool to other public aids. It indicates that works are highly motivated by a search for energy savings, and are actually efficient to meet this objective

  5. Energy Efficiency Improvement and Cost Saving Opportunities for the Glass Industry. An ENERGY STAR Guide for Energy and Plant Managers

    Energy Technology Data Exchange (ETDEWEB)

    Galitsky, Christina; Worrell, Ernst; Galitsky, Christina; Masanet, Eric; Graus, Wina

    2008-03-01

    The U.S. glass industry is comprised of four primary industry segments--flat glass, container glass, specialty glass, and fiberglass--which together consume $1.6 billion in energy annually. On average, energy costs in the U.S. glass industry account for around 14 percent of total glass production costs. Energy efficiency improvement is an important way to reduce these costs and to increase predictable earnings, especially in times of high energy price volatility. There is a variety of opportunities available at individual plants in the U.S. glass industry to reduce energy consumption in a cost-effective manner. This Energy Guide discusses energy efficiency practices and energy-efficient technologies that can be implemented at the component, process, system, and organizational levels. A discussion of the trends, structure, and energy consumption characteristics of the U.S. glass industry is provided along with a description of the major process steps in glass manufacturing. Expected savings in energy and energy-related costs are given for many energy efficiency measures, based on case study data from real-world applications in glass production facilities and related industries worldwide. Typical measure payback periods and references to further information in the technical literature are also provided, when available. The information in this Energy Guide is intended to help energy and plant managers in the U.S. glass industry reduce energy consumption in a cost-effective manner while maintaining the quality of products manufactured. Further research on the economics of the measures--as well on as their applicability to different production practices--is needed to assess potential implementation of selected technologies at individual plants.

  6. The tax credit in favor of the renewable energies and the energy savings bear fruits

    International Nuclear Information System (INIS)

    2006-01-01

    This document presents in the first part the positive economical results obtained by the implementing in January 2005, of a tax credit majored of 40% in favor of equipments using a renewable energy source. The second part is devoted to other financial incentives in the domain of energy saving and renewable energies uses. Specifications concerning the equipments and legal aspects are presented. (A.L.B.)

  7. A CLS-based survivable and energy-saving WDM-PON architecture

    Science.gov (United States)

    Zhu, Min; Zhong, Wen-De; Zhang, Zhenrong; Luan, Feng

    2013-11-01

    We propose and demonstrate an improved survivable and energy-saving WDM-PON with colorless ONUs. It incorporates both energy-saving and self-healing operations. A simple effective energy-saving scheme is proposed by including an energy-saving control unit in the OLT and a control unit at each ONU. The energy-saving scheme realizes both dozing and sleep (offline) modes, which greatly improves the energy-saving efficiency for WDM-PONs. An intelligent protection switching scheme is designed in the OLT, which can distinguish if an ONU is in dozing/sleep (offline) state or a fiber is faulty. Moreover, by monitoring the optical power of each channel on both working and protection paths, the OLT can know the connection status of every fiber path, thus facilitating an effective protection switching and a faster failure recovery. The improved WDM-PON architecture not only significantly reduces energy consumption, but also performs self-healing operation in practical operation scenarios. The scheme feasibility is experimentally verified with 10 Gbit/s downstream and 1.25 Gbit/s upstream transmissions. We also examine the energy-saving efficiency of our proposed energy-saving scheme by simulation, which reveals that energy saving mainly arises from the dozing mode, not from the sleep mode when the ONU is in the online state.

  8. Understanding the spectrum of residential energy-saving behaviours: French evidence using disaggregated data

    International Nuclear Information System (INIS)

    Belaïd, Fateh; Garcia, Thomas

    2016-01-01

    Analysing household energy-saving behaviours is crucial to improve energy consumption predictions and energy policy making. How should we quantitatively measure them? What are their determinants? This study explores the main factors influencing residential energy-saving behaviours based on a bottom-up multivariate statistical approach using data from the recent French PHEBUS survey. Firstly, we assess energy-saving behaviours on a one-dimension scale using IRT. Secondly, we use linear regression with an innovative variable selection method via adaptive lasso to tease out the effects of both macro and micro factors on the behavioural score. The results highlight the impact of five main attributes incentivizing energy-saving behaviours based on cross-variable analyses: energy price, household income, education level, age of head of household and dwelling energy performance. In addition, our results suggest that the analysis of the inverted U-shape impact of age enables the expansion of the energy consumption life cycle theory to energy-saving behaviours. - Highlights: • We examine the main factors influencing residential energy-saving behaviours. • We use data from the recent French PHEBUS survey. • We use IRT to assess energy-saving behaviours on a one-dimension scale. • We use linear regression with an innovative variable selection method via adaptive lasso. • We highlight the impact of five main attributes incentivizing energy-saving behaviours.

  9. Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

    Energy Technology Data Exchange (ETDEWEB)

    Carmichael, Scott [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States); Robertson, Joseph [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chin, Justin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, Dane [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Jacquelyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, Doug [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-07-01

    Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partly because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.

  10. Nash Equilibrium of an Energy Saving Strategy with Dual Rate Transmission in Wireless Regional Area Network

    Directory of Open Access Journals (Sweden)

    Zhanqiang Huo

    2017-01-01

    Full Text Available Wireless regional area network (WRAN adopts centralized network architecture and is currently one of the most typical cognitive radio networks. In order to reduce the energy consumption of the communication networks with the constraint of spectrum resource utilization, a working sleep mechanism is introduced into the base station (BS, and a novel energy saving strategy with dual rate transmission is proposed. Combining the multiple-vacation queue and priority queue, using the quasi-birth-death process and the matrix-geometric solution method, we assess the average latency and the forced termination probability of secondary user packets, as well as the energy saving ratio and the channel utilization of system. Based on the revenue-expenditure structure, a profit function is built, and then the Nash equilibrium behavior and the socially optimal behavior are investigated. With the help of the particle swarm optimization, an intelligent optimization algorithm to search the socially optimal arrival rate of secondary user packets is presented. In order to unify the arrival rates of secondary user packets with Nash equilibrium and social optimization, a reasonable pricing policy is formulated. In addition, system experiments are carried out to verify the effectiveness of the energy saving strategy and the rationality of the pricing policy.

  11. Consumers’ perceptions of energy use and energy savings: A literature review

    Science.gov (United States)

    Lesic, Vedran; Bruine de Bruin, Wändi; Davis, Matthew C.; Krishnamurti, Tamar; Azevedo, Inês M. L.

    2018-03-01

    Background. Policy makers and program managers need to better understand consumers’ perceptions of their energy use and savings to design effective strategies for promoting energy savings. Methods. We reviewed 14 studies from the emerging interdisciplinary literature examining consumers’ perceptions electricity use by specific appliances, and potential savings. Results. We find that: (1) electricity use is often overestimated for low-energy consuming appliances, and underestimated for high-energy consuming appliances; (2) curtailment strategies are typically preferred over energy efficiency strategies; (3) consumers lack information about how much electricity can be saved through specific strategies; (4) consumers use heuristics for assessing the electricity use of specific appliances, with some indication that more accurate judgments are made among consumers with higher numeracy and stronger pro-environmental attitudes. However, design differences between studies, such as variations in reference points, reporting units and assessed time periods, may affect consumers’ reported perceptions. Moreover, studies differ with regard to whether accuracy of perceptions was evaluated through comparisons with general estimates of actual use, self-reported use, household-level meter readings, or real-time smart meter readings. Conclusion. Although emerging findings are promising, systematic variations in the measurement of perceived and actual electricity use are potential cause for concern. We propose avenues for future research, so as to better understand, and possibly inform, consumers’ perceptions of their electricity use. Ultimately, this literature will have implications for the design of effective electricity feedback for consumers, and related policies.

  12. An exploration of possible design options for a binding energy savings target in Europe

    NARCIS (Netherlands)

    Harmsen, Robert; Eichhammer, Wolfgang; Wesselink, Bart

    2014-01-01

    As Europe is not on track in meeting its 2020 energy savings target, there has been quite some debate to make the energy savings target binding instead of indicative. Although the final draft text of the Energy Efficiency Directive left the option of a binding target explicitly open for the period

  13. Review of the Application of Green Building and Energy Saving Technology

    Science.gov (United States)

    Tong, Zhineng

    2017-12-01

    The use of energy-saving technologies in green buildings should run through the entire process of building design, construction and use, enabling green energy-saving technologies to maximize their effectiveness in construction. Realize the sustainable development of green building, reduce energy consumption, reduce people’s interference with the natural environment, suitable for people living in “green” building.

  14. Regional Super ESPC Saves Energy and Dollars at NASA's Johnson Space Center

    International Nuclear Information System (INIS)

    Federal Energy Management Program

    2001-01-01

    This case study about energy saving performance contacts (ESPCs) presents an overview of how the NASA's Johnson Space Flight Center established an ESPC contract and the benefits derived from it. The Federal Energy Management Program instituted these special contracts to help federal agencies finance energy-saving projects at their facilities

  15. Reported Energy and Cost Savings from the DOE ESPC Program: FY 2015

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Bob S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-01-01

    The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 151 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project.

  16. The role of CSR in promoting companies’ energy-saving actions in two Asian cities

    International Nuclear Information System (INIS)

    Hori, Shiro; Shinozaki, Mami; Nogata, Daisuke; Fujita, Toshiyuki

    2014-01-01

    In Asian developing countries, energy saving has become a crucial issue in sustainable development. However, in countries that possess weak government regulations and market mechanisms, industries are expected to save energy voluntarily. Therefore, corporate social responsibility (CSR) can serve as an important incentive to encourage companies to take voluntary actions. In this paper, we analyze CSR recognition and energy-saving actions taken by companies located in two Asian cities. The results of a questionnaire survey revealed that a positive relation exists between CSR recognition and energy saving. In developing countries, CSR develops based on concerns expressed by local cultures and communities. This indicates that the positive relationships that exist between CSR and energy-saving actions reflect the social norms of these communities. The results suggest that policies that encourage companies to enhance their CSR activities in society can serve as effective incentives to encourage energy-saving actions. - Highlights: • In Asian cities, energy saving has become a crucial issue in sustainable development. • CSR can serve as an important incentive to take voluntary energy saving actions. • The survey revealed a positive relation between CSR and energy saving. • The policies enhancing their CSR activities in society can serve as effective incentives

  17. Energy Saving Recommended: Delivering improved product standards, market presence and quality

    Energy Technology Data Exchange (ETDEWEB)

    Lock, Tom; Galvanoni, Frances [Energy Saving Trust (United Kingdom)

    2007-07-01

    CO{sub 2} emissions from the home equate to 27 % of UK total emissions. In order for consumers to use less energy, and reduce their environmental impact, the Energy Saving Recommended (ESR) voluntary product labelling scheme for domestic energy saving products was established to direct the consumer to choose better products and make smarter choices. With over 2000 certified products, ESR is present across 5 sectors and covers 24 product categories; 9 sets of standards were reviewed and revised in 2005/6 and a further 13 were delivered in 2006/7. ESR is now implementing existing and developing new standards in consumer electronics - from integrated digital televisions and recorders, to intelligent mains sockets and set-top-boxes, as well as assessing the feasibility of endorsing domestic ICT equipment. The Energy Saving Trust, through its marketing activities, acts as an enabler to make energy saving action simpler, easier and cheaper for the consumer to undertake. Using a variety of communication strategies the trade is engaged through the provision of value added member benefits; a holistic approach is taken with key partners to integrate energy efficiency throughout their businesses. Merchandising support helps product standards to be implemented in the market place; evaluation and research work demonstrates that markets can be changed and shows a 1 in 3 label recognition rate. The credibility and integrity of the label are reinforced through compliance testing, in-store and online label monitoring and legal enforcement, frequent data checks and the integration of ISO best practice standards through the certification system.

  18. Energy usage and technical potential for energy saving measures in the Swedish residential building stock

    International Nuclear Information System (INIS)

    Mata, Érika; Sasic Kalagasidis, Angela; Johnsson, Filip

    2013-01-01

    This paper provides an analysis of the current energy usage (net energy and final energy by fuels) and associated carbon dioxide (CO 2 ) emissions of the Swedish residential building stock, which includes single-family dwellings and multi-family dwellings. Twelve energy saving measures (ESMs) are assessed using a bottom–up modeling methodology, in which the Swedish residential stock is represented by a sample of 1400 buildings (based on data from the year 2005). Application of the ESMs studied gives a maximum technical reduction potential in energy demand of 53%, corresponding to a 63% reduction in CO 2 emissions. Although application of the investigated ESMs would reduce CO 2 emissions, the measures that reduce electricity consumption for lighting and appliances (LA) will increase CO 2 emissions, since the saved electricity production is less CO 2 -intensive than the fuel mix used for the increased space heating required to make up for the loss in indirect heating obtained from LA. - Highlights: ► Analysis of year 2005energy use and CO2 emissions of Swedish residential buildings. ► Includes all single-family dwellings and multi-family dwellings. ► Bottom–up modeling of building stock represented by 1400 buildings. ► Technical effects of 12 energy saving measures are assessed. ► Energy demand can be reduced by53% and associated CO 2 emissions by 63%

  19. Sensitivity Analysis of Accumulated Savings in Defined Contribution Pension System

    Directory of Open Access Journals (Sweden)

    Mladen Latković

    2009-12-01

    Full Text Available In this article we analyze the effect of parameters in the standard model for calculation of accumulated savings in a defined contribution pension system. Three parameters affect accumulated savings in the standard model: saving duration, return of the pension fund and the growth in employee gross wage. By using a linear approximation we calculated marginal contributions for small changes in the parameters of the standard model and analyzed their relations for a set of referent parameters which are most suitable for the 2nd pillar pension system in Croatia. It is shown that the return of a pension fund has a major influence on accumulated savings, while the influence of the growth in employee gross wage is slightly smaller. Also, we calculated the influence of raising the contribution rate in the 2nd pillar on the accumulated savings in a simple scenario in which that rate is raised by equal amounts over the whole of a saving period. These results allow easier planning of pension insurance in the defined contribution system at a general level as well as at an individual level.

  20. Estimation of energy saving thanks to a reduced-model-based approach: Example of bread baking by jet impingement

    International Nuclear Information System (INIS)

    Alamir, M.; Witrant, E.; Della Valle, G.; Rouaud, O.; Josset, Ch.; Boillereaux, L.

    2013-01-01

    In this paper, a reduced order mechanistic model is proposed for the evolution of temperature and humidity during French bread baking. The model parameters are identified using experimental data. The resulting model is then used to estimate the potential energy saving that can be obtained using jet impingement technology when used to increase the heat transfer efficiency. Results show up to 16% potential energy saving under certain assumptions. - Highlights: ► We developed a mechanistic model of heat and mass transfer in bread including different and multiple energy sources. ► An optimal control system permits to track references trajectories with a minimization of energy consuming. ► The methodology is evaluated with jet impingement technique. ► Results show a significant energy saving of about 17% of energy with reasonable actuator variations

  1. Challenges and Opportunities To Achieve 50% Energy Savings in Homes: National Laboratory White Papers

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, M. V. A.

    2011-07-01

    In 2010, researchers from four of the national laboratories involved in residential research (Lawrence Berkeley National Laboratory, National Renewable Energy Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory) were asked to prepare papers focusing on the key longer term research challenges, market barriers, and technology gaps that must be addressed to achieve the longer term 50% saving goal for Building America to ensure coordination with the Building America industry teams who are focusing their research on systems to achieve the near-term 30% savings goal. Although new construction was included, the focus of the effort was on deep energy retrofits of existing homes. This report summarizes the key opportunities, gaps, and barriers identified in the national laboratory white papers.

  2. Returns on investments in energy-saving technologies under energy price uncertainty in Dutch greenhouse horticulture

    NARCIS (Netherlands)

    Diederen, P.J.M.; Tongeren, van F.W.; Veen, van der H.B.

    2003-01-01

    Conventional net present value calculations evaluating the profitability of investments in energy-saving technologies in Dutch horticultural outlays predict a much higher rate of adoption of these technologies than is actually observed. This paper tries to explain this gap by applying a real options

  3. Factors influencing energy-saving behavior of urban households in Jiangsu Province

    International Nuclear Information System (INIS)

    Yue, Ting; Long, Ruyin; Chen, Hong

    2013-01-01

    In this research, the willingness of households to adopt different energy-saving behavior has been analyzed, and factors influencing energy-saving behavior in Jiangsu Province, China, have been examined. The study builds on a broad and practical conceptual framework that embraces three types of energy-saving behavior and four dimensions of influencing factors, including socio-demographics, energy-saving awareness, behavioral ability, and situational factors. The empirical results are based on an Internet survey that was sent out to 638 households. The results indicate that socio-demographic characteristics, including age, gender, income level, household structure, and educational background, are all important factors influencing energy-saving behavior. At present, respondents adopt the usage-reduction type of behavior more often than the other two types, which require a greater capacity to pay for energy-efficient products and a higher level of energy-saving awareness. Situational factors have significant positive moderating effects when the variables of behavioral ability and energy-saving awareness act on energy-saving behavior. In addition, the results also show that spatial differences exist among the three regions of Jiangsu Province. Finally, some implications of these results for the design of future incentive policies and measures to encourage energy-saving behavior are presented. -- Highlights: •A broad and practical conceptual framework of energy-saving behaviors is built. •Socio-demographic characteristics are determinants of energy-saving behavior. •Respondents adopt the usage-reduction type more often than the other two types. •Situational factors have positive moderating effects on the other two variables. •Spatial differences exist among the three regions of Jiangsu Province

  4. Energy-saving method for technogenic waste processing.

    Directory of Open Access Journals (Sweden)

    Bayandy Dikhanbaev

    Full Text Available Dumps of a mining-metallurgical complex of post-Soviet Republics have accumulated a huge amount of technogenic waste products. Out of them, Kazakhstan alone has preserved about 20 billion tons. In the field of technogenic waste treatment, there is still no technical solution that leads it to be a profitable process. Recent global trends prompted scientists to focus on developing energy-saving and a highly efficient melting unit that can significantly reduce specific fuel consumption. This paper reports, the development of a new technological method-smelt layer of inversion phase. The introducing method is characterized by a combination of ideal stirring and ideal displacement regimes. Using the method of affine modelling, recalculation of pilot plant's test results on industrial sample has been obtained. Experiments show that in comparison with bubbling and boiling layers of smelt, the degree of zinc recovery increases in the layer of inversion phase. That indicates the reduction of the possibility of new formation of zinc silicates and ferrites from recombined molecules of ZnO, SiO2, and Fe2O3. Calculations show that in industrial samples of the pilot plant, the consumption of natural gas has reduced approximately by two times in comparison with fuming-furnace. The specific fuel consumption has reduced by approximately four times in comparison with Waelz-kiln.

  5. Energy-saving method for technogenic waste processing.

    Science.gov (United States)

    Dikhanbaev, Bayandy; Gomes, Chandima; Dikhanbaev, Aristan Bayandievich

    2017-01-01

    Dumps of a mining-metallurgical complex of post-Soviet Republics have accumulated a huge amount of technogenic waste products. Out of them, Kazakhstan alone has preserved about 20 billion tons. In the field of technogenic waste treatment, there is still no technical solution that leads it to be a profitable process. Recent global trends prompted scientists to focus on developing energy-saving and a highly efficient melting unit that can significantly reduce specific fuel consumption. This paper reports, the development of a new technological method-smelt layer of inversion phase. The introducing method is characterized by a combination of ideal stirring and ideal displacement regimes. Using the method of affine modelling, recalculation of pilot plant's test results on industrial sample has been obtained. Experiments show that in comparison with bubbling and boiling layers of smelt, the degree of zinc recovery increases in the layer of inversion phase. That indicates the reduction of the possibility of new formation of zinc silicates and ferrites from recombined molecules of ZnO, SiO2, and Fe2O3. Calculations show that in industrial samples of the pilot plant, the consumption of natural gas has reduced approximately by two times in comparison with fuming-furnace. The specific fuel consumption has reduced by approximately four times in comparison with Waelz-kiln.

  6. Simultaneous Energy Savings and IEQ Improvements in Relocatable Classrooms

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Dibartolomeo, Dennis; Hotchi, Toshi; Hodgson, Alfred T.; Lee, Seung-Min; Liff, Shawna M.; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

    2003-05-22

    Relocatable classrooms (RCs) are commonly used by school districts with changing demographics and enrollment sizes. We designed and constructed four energy-efficient RCs for this study to demonstrate technologies with the potential to simultaneously improve energy efficiency and indoor environmental quality (IEQ). Two were installed at each of two school districts, and energy use and IEQ parameters were monitored during occupancy. Two RCs (one per school) were finished with materials selected for reduced emissions of toxic and odorous volatile organic compounds (VOCs). Each had two HVAC systems, operated on alternate weeks, consisting of a standard heat-pump system and an indirect-direct evaporative cooling (IDEC) system with gas-fired hydronic heating. The IDEC system provides continuous outside air ventilation at {sup 3}15 CFM (7.5 L s-1) person-1, efficient particle filtration while using significantly less energy for cooling. School year long measurements included: carbon dioxide (CO2), particles, VOCs, temperature, humidity, thermal comfort, noise, meteorology, and energy use. IEQ monitoring results indicate that important ventilation-relevant indoor CO2 and health-relevant VOC concentration reductions were achieved while average cooling and heating energy costs were simultaneously reduced by 50 percent and 30 percent, respectively.

  7. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.; Zhang, Jian; Wang, Weimin

    2016-02-15

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energy code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.

  8. Technical Support Document: Development of the Advanced Energy Design Guide for Medium Box Retail -- 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E. T.; Macumber, D. L.; Long, N. L.; Griffith, B. T.; Benne, K. S.; Pless, S. D.; Torcellini, P. A.

    2008-09-01

    This report provides recommendations that architects, designers, contractors, developers, owners, and lessees of medium box retail buildings can use to achieve whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004. The recommendations are given by climate zone and address building envelope, fenestration, lighting systems, HVAC systems, building automation and controls, outside air treatment, service water heating, plug loads, and photovoltaic systems. The report presents several paths to 50% savings, which correspond to different levels of integrated design. These are recommendations only, and are not part of a code or standard. The recommendations are not exhaustive, but we do try to emphasize the benefits of integrated building design, that is, a design approach that analyzes a building as a whole system, rather than as a disconnected collection of individually engineered subsystems.

  9. Crop based climate regimes for energy saving in greenhouse cultivation

    Energy Technology Data Exchange (ETDEWEB)

    Koerner, O.

    2003-06-16

    Sustainability is one of the major aims in greenhouse horticulture. According to agreements between the Dutch grower association and the government, energy consumption and the use of chemical biocides have to be reduced. More advanced greenhouse technique is being developed to reach the target to decrease the energy efficiency-index by 65% between 1980 and 2010. However, this could also be achieved with existing technology by using more advanced climate regimes. The present thesis aimed at that, through designing and analysing climate regimes while employing existing climate control possibilities. Theoretical temperature and humidity regimes were designed to decrease energy consumption and a photosynthesis maximisation procedure was implemented to maximise growth. The basis for a crop gross photosynthesis model for control purposes was created. Crop photosynthesis models were evaluated at conditions expected to occur with more sustainable climate regimes. It was shown with experimental evidence that theoretical assumptions on the temperature - CO2 effects in a crop that are based on theoretically models scaling up leaf photosynthesis to the crop level are valid and that simplified existing models could be applied up to 28C. With higher temperatures new designs are needed and this can probably be achieved with an improved stomata-resistance model. The well known temperature integration principle was modified with two nested time-frames (24-hour and six days) and a temperature dose-response function. In a year round tomato cultivation, energy consumption was predicted to decrease with up to 9 % compared to regular temperature integration. The potential for energy saving with temperature integration is limited by humidity control when as usual fixed set points are maintained, because it counteracts temperature integration. Vents open at lower temperatures and heating is switched on at higher temperatures than required for optimal effects of temperature integration. A

  10. Where to place the saving obligation: Energy end-users or suppliers?

    International Nuclear Information System (INIS)

    Bertoldi, Paolo; Labanca, Nicola; Rezessy, Silvia; Steuwer, Sibyl; Oikonomou, Vlasis

    2013-01-01

    Obligations to save energy differentiate, among other features, by obliged parties. These are obligations on energy suppliers and energy end-users. Supplier obligations have been introduced in North America, Europe and Australia. Under supplier obligations energy suppliers have to comply with mandatory energy saving targets and thus they implement (directly or via third parties) energy efficiency projects on their clients’ premises, or they decide to trade certified project savings if this option is envisaged by their obligation scheme. In several emerging schemes such as the UK Carbon Reduction Commitment (CRC) Energy Efficiency Scheme, the Tokyo Emission Trading Scheme or the Perform Achieve and Trade (PAT) Scheme in India, the obligation to reduce energy consumption is placed on large end-users directly and end-users are allowed to trade emissions allowances or energy saving certificates. The paper starts with presenting these two conceptually different ways for introducing energy saving obligations. Then it analyses advantages and disadvantages of end-users obligations compared to suppliers obligations. The preliminary conclusion of the paper is that supplier obligations seem to be well-suited for the residential sector, but end-user saving obligations may offer advantages when it comes to the industrial and commercial sectors. - Highlights: • We present different ways for introducing energy saving obligations. • We analyse energy end-users obligations vs. supplier obligations. • Supplier obligations seem to be well-suited for the residential sector. • End-user obligations offer advantages in the industrial and commercial sectors

  11. R and D of energy saving and new energy utilization in Japanese marine engineering

    Science.gov (United States)

    Isshiki, N.; Tamaki, H.; Murayama, Y.; Tokuda, S.

    Energy saving measures being studied and implemented in Japan to reduce marine diesel fuel consumption are described. Lower ship speeds, bulb bows, better surface paint, a reaction ladder, low speed diesel engines with long stroke cylinders and superchargers are being tried. Large, low speed, controllable pitch propellers, digital engine control, and waste heat recovery with Rankine cycle generators are other methods under investigation. Blade cooling and reheating are being introduced, and a set of computer controlled maneuverable metal sails undergoing sea tests on a commercial tanker as a fuel saving technique have displayed a 20% fuel savings in tests. A windmill is under design for ship propulsion, involving several vertical airfoils revolving around a vertical axis of rotation. Direct connection to a propeller is being considered, noting that operations to windward would be possible.

  12. Energy-Saving Performance of Flap-Adjustment-Based Centrifugal Fan

    Directory of Open Access Journals (Sweden)

    Genglin Chen

    2018-01-01

    Full Text Available The current paper mainly focuses on finding a more appropriate way to enhance the fan performance at off-design conditions. The centrifugal fan (CF based on flap-adjustment (FA has been investigated through theoretical, experimental, and finite element methods. To obtain a more predominant performance of CF from the different adjustments, we carried out a comparative analysis on FA and leading-adjustment (LA in aerodynamic performances, which included the adjusted angle of blades, total pressure, efficiency, system-efficiency, adjustment-efficiency, and energy-saving rate. The contribution of this paper is the integrated performance curve of the CF. Finally, the results showed that the effects of FA and LA on economic performance and energy savings of the fan varied with the blade angles. Furthermore, FA was feasible, which is more sensitive than LA. Moreover, the CF with FA offered a more extended flow-range of high economic characteristic in comparison with LA. Finally, when the operation flow-range extends, energy-saving rate of the fan with FA would have improvement.

  13. Evolution of China's power dispatch principle and the new energy saving power dispatch policy

    International Nuclear Information System (INIS)

    Ciwei, Gao; Yang, Li

    2010-01-01

    With social economic reform in the past decades, the power industry of China is gradually evolving from a highly integrated one toward an electricity market, which can be characterized based on the transition of the power dispatch principle. To attract investment in the power generating industry, China introduced non-state-owned power plants to the original system of a highly vertically integrated power industry with annual power generation quota guarantees, which makes the traditional economic dispatch principle not applicable. The newly debuted energy saving power dispatch (ESPD) is an attempt to fully exploit the maximum energy savings and was implemented by an administrative code. Starting in August 2007, the pilot operation of the ESPD was implemented in five provinces, but after two years, it is still not widely applied all over the country. This paper details the transition of China's power dispatch principle with particular attention to its origin and content. Moreover, the factors that influence the ESPD's actual energy saving effect are discussed, as well as the sustainability of the policy. (author)

  14. Energy efficiency system development

    Science.gov (United States)

    Leman, A. M.; Rahman, K. A.; Chong, Haw Jie; Salleh, Mohd Najib Mohd; Yusof, M. Z. M.

    2017-09-01

    By subjecting to the massive usage of electrical energy in Malaysia, energy efficiency is now one of the key areas of focus in climate change mitigation. This paper focuses on the development of an energy efficiency system of household electrical appliances for residential areas. Distribution of Questionnaires and pay a visit to few selected residential areas are conducted during the fulfilment of the project as well as some advice on how to save energy are shared with the participants. Based on the collected data, the system developed by the UTHM Energy Team is then evaluated from the aspect of the consumers' behaviour in using electrical appliances and the potential reduction targeted by the team. By the end of the project, 60% of the participants had successfully reduced the electrical power consumption set by the UTHM Energy Team. The reasons for whether the success and the failure is further analysed in this project.

  15. Novel surface measurement system reading cost savings

    Energy Technology Data Exchange (ETDEWEB)

    Sword, M.

    1996-05-01

    A new state-of-the-art data acquisition system for the oil and natural gas industries is being marketed by OPSCO`92 Industries Ltd. The unit is portable, it measures surface data which is calibrated to bottom-hole conditions and designed to measure temperature and pressure information without the necessity of sending testing equipment downhole. The Surface Data System (SDS) uses silicon-crystal technology, is mounted in a suitcase size carrying case, and runs off a 12-volt battery enclosure which can be backed up by a small solar panel. The first generation system can handle 16 different channels of information input on a laptop computer. Pressure, pressure differential, temperature, frequency and pulse signals for flow meter measurements are handled by standard sensors. Areas of application include build-up and fall-off tests, pipeline evaluation, pre-frac tests, underbalanced drilling and gas well evaluation. 1 fig., 1 photo.

  16. Community based social marketing for implementation of energy saving targets at local level

    Directory of Open Access Journals (Sweden)

    Dalia Streimikiene

    2015-05-01

    Full Text Available Energy saving and greenhouse gas (GHG emission reduction policies at local level need to be investigated and new tools for climate change mitigation are necessary seeking to achieve GHG emission targets in Lithuania. Most Lithuanian municipalities have signed Covenant of Mayors and have prepared local energy action plans. However, all these plans include just energy saving measures on supply side and renovation of buildings. Nevertheless, the significant energy savings and GHG emission reductions can be achieved through behavioural changes. The aim of the paper is to apply community based social marketing approach in assessment of achievable energy saving and GHG emission reduction targets set by local energy action plans. The paper presents the results of case study implemented in Kaunas region municipality. The case study was conducted by creating focus groups and applying two scenarios: baseline or doing nothing and climate change mitigation scenario including intervention measures. The results of case study revealed that the total energy consumption reduction target set in Sustainable energy development strategy of Kaunas region county - 11% - can be achieved by combining results of energy consumption reduction in both focus groups. The survey conducted after study finalization revealed that respondents were provided with a lot of additional knowledge during the study and achieved real money savings. The major barriers of energy savings in households are related with the lack of information on energy savings and GHG emission reduction.

  17. Options for Water, Energy and Chemical Savings for Finitex, Cape Town

    DEFF Research Database (Denmark)

    Schneider, Zsig; Wenzel, Henrik

    An analysis of the options identified for saving of water, energy and chemicals was conducted at Finitex, Cape Town on the 18th October 2002. Cost savings were calculated from an estimation of the reduction in cost of water, energy and chemical usage associated with various interventions. Capital...

  18. Global Energy-saving Map of Strong Ocean Currents

    Science.gov (United States)

    2015-01-01

    Current between Taipei and Tokyo at an average speed of 12 knots. Effective use of these strong currents can yield huge savings considering that a...and the top five importers are China, United States, Japan, Taiwan, and South Korea. Overall, strong economic activities take place in the Asian Pacific...ship routers. On the route of the KC region between Tokyo and Taipei (∼ 1100 nm), ships can save 2–6% fuel with sailing speeds of around 12 knots

  19. Advanced, Integrated Control for Building Operations to Achieve 40% Energy Saving

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yan; Song, Zhen; Loftness, Vivian; Ji, Kun; Zheng, Sam; Lasternas, Bertrand; Marion, Flore; Yuebin, Yu

    2012-10-15

    We developed and demonstrated a software based integrated advanced building control platform called Smart Energy Box (SEB), which can coordinate building subsystem controls, integrate variety of energy optimization algorithms and provide proactive and collaborative energy management and control for building operations using weather and occupancy information. The integrated control system is a low cost solution and also features: Scalable component based architecture allows to build a solution for different building control system configurations with needed components; Open Architecture with a central data repository for data exchange among runtime components; Extendible to accommodate variety of communication protocols. Optimal building control for central loads, distributed loads and onsite energy resource; uses web server as a loosely coupled way to engage both building operators and building occupants in collaboration for energy conservation. Based on the open platform of SEB, we have investigated and evaluated a variety of operation and energy saving control strategies on Carnegie Mellon University Intelligent Work place which is equipped with alternative cooling/heating/ventilation/lighting methods, including radiant mullions, radiant cooling/heating ceiling panels, cool waves, dedicated ventilation unit, motorized window and blinds, and external louvers. Based on the validation results of these control strategies, they were integrated in SEB in a collaborative and dynamic way. This advanced control system was programmed and computer tested with a model of the Intelligent Workplace's northern section (IWn). The advanced control program was then installed in the IWn control system; the performance was measured and compared with that of the state of the art control system to verify the overall energy savings great than 40%. In addition advanced human machine interfaces (HMI's) were developed to communicate both with building

  20. Development of Android based Smart Power Saving System

    Science.gov (United States)

    Gupta, Ashutosh; Kumar, Pradeep; Ghosh, Tathagata; Bhawna, Shruthi. S.

    2017-08-01

    An android based smart power saving system has been presented in this paper. For this purpose, an application is developed for controlling the intensity of an AC supply using a dimmer circuit in android platform and to monitor the current flow on different intensity level a current sensor is used in the circuit. Dimmer circuit provides a 16-different intensity level to control the flow of current and help in power saving. The system is very simple and robust as it is based on android platform.