WorldWideScience

Sample records for sweating hot plate

  1. Sweating

    Science.gov (United States)

    ... Home Body Looking and feeling your best Sweating Sweating You might think that you are only supposed to sweat when you are hot, but once you hit puberty, you will also sweat when you are nervous. Your sweat glands, which ...

  2. Cancer treatment: dealing with hot flashes and night sweats

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000826.htm Cancer treatment: dealing with hot flashes and night sweats To use ... stress reduction. Learning how to decrease stress and anxiety may help relieve hot flashes in some people. ...

  3. Hot Flashes amd Night Sweats (PDQ)

    Science.gov (United States)

    ... that it is only slightly better than a placebo (pill that has no effect). Most studies of soy and black cohosh show they are no better than a placebo in reducing hot flashes. Soy contains estrogen -like substances; the effect of soy on the risk of breast cancer ...

  4. Hydration and sweating responses to hot-weather football competition.

    Science.gov (United States)

    Kurdak, S S; Shirreffs, S M; Maughan, R J; Ozgünen, K T; Zeren, C; Korkmaz, S; Yazici, Z; Ersöz, G; Binnet, M S; Dvorak, J

    2010-10-01

    During a football match played in warm (34.3 ± 0.6 °C), humid (64 ± 2% rh) conditions, 22 male players had their pre-match hydration status, body mass change, sweat loss and drinking behavior assessed. Pre-match urine specific gravity (1.012 ± 0.006) suggested that all but three players commenced the match euhydrated. Players lost 3.1 ± 0.6 L of sweat and 45 ± 9 mmol of sodium during the 90-min match and replaced 55 ± 19% of their sweat losses and hence by the end of the game were 2.2 ± 0.9% lighter. The water volume consumed during the game was highly variable (1653 ± 487 mL; 741-2387 mL) but there was a stronger relationship between the estimated pre-game hydration status and water volume consumed, than between sweat rate and water volume consumed. In a second match, with the same players 2 weeks later in 34.4 ± 0.6 °C, 65 ± 3% rh, 11 players had a sports drink available to them before and during the match in addition to water. Total drink volume consumed during the match was the same, but approximately half the volume was consumed as sports drink. The results indicate that substantial sweat water and electrolyte losses can occur during match play in hot conditions and a substantial water and sodium deficit can occur in many players even when water or sports drink is freely available. © 2010 John Wiley & Sons A/S.

  5. Sweat

    Science.gov (United States)

    Sweat is a clear, salty liquid produced by glands in your skin. Sweating is how your body cools itself. You sweat mainly under your arms and on your feet and palms. When sweat mixes with bacteria on your skin, it can ...

  6. Association between pulse wave velocity and hot flashes/sweats in middle-aged women.

    Science.gov (United States)

    Yang, Ruwei; Zhou, Yang; Li, Changbin; Tao, Minfang

    2017-10-23

    As women age and go through menopause, they suffer a higher incidence of cardiovascular morbidity and mortality. Previous studies have shown that a relationship exists between hot flashes/sweats and an increased risk of cardiovascular disease. However, the association between hot flashes/sweats and arterial stiffness is unclear. We aim to explore the relationship between hot flashes/sweats and arterial stiffness using the modified Kupperman index (KMI) questionnaire and measure the brachial-ankle pulse wave velocity (baPWV). The prevalence of hot flashes in our research was reported to be 41.77%. There was a statistically significant difference between the mean baPWV among groups that experienced different severities of hot flashes/sweats according to one-way ANOVA test (p hot flashes/sweats based on linear regression after adjusting for established cardiovascular confounders (95% CI: (5.86, 43.23), p = 0.01). To the best of our knowledge, this study is the first investigation to propose that baPWV may serve both as an objective index for evaluating the severity of hot flashes/sweats and as a predictor of arterial stiffness beyond Cardiac Vascular Disease (CVD) risk factors in middle-aged women.

  7. Sweating

    Science.gov (United States)

    ... treat mental disorders Menopause Spicy foods (known as "gustatory sweating") Warm temperatures Withdrawal from alcohol or narcotic ... D, Chelimsky G. Disorders of the autonomic nervous system. In: Daroff RB, Fenichel GM, Jankovic J, Mazziotta ...

  8. Line Heat-Source Guarded Hot Plate

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. This facility provides for absolute measurement of thermal...

  9. Health-related quality of life of women with menopausal hot flushes and night sweats.

    Science.gov (United States)

    Ayers, B; Hunter, M S

    2013-04-01

    Despite a large body of research on menopause, there is little definitive evidence of the impact of vasomotor symptoms on health-related quality of life (HrQoL). Therefore, this study describes the HrQoL of menopausal women with hot flushes and night sweats and examines predictors of HrQoL. A total of 140 women reporting at least ten hot flushes/night sweats (vasomotor symptoms) a week for at least a month completed an assessment interview (including medical history, past and current physical and mental health and menopausal status) and questionnaires eliciting sociodemographic and help-seeking information, HrQoL and the Hot Flush Rating Scale. Women with vasomotor symptoms reported somewhat reduced HrQoL compared to SF-36 US norms and a general sample of UK menopausal women; 53% reported comorbid physical illness and 66% had current psychosocial concerns; 77% had visited their doctor about menopausal symptoms; 28% were past and 3% current users of hormone therapy. Overall, poor HrQoL was associated with having problematic hot flushes, current psychosocial concerns, (younger) age, (higher) body mass index and poor general health. This sample of relatively healthy mid-aged women with vasomotor symptoms reported reduced HrQoL compared to age-matched norms and a general sample of menopausal women. Problem rating, rather than frequency, of hot flushes was associated with reduced HrQoL, as were health and psychosocial factors.

  10. Using traditional acupuncture for breast cancer-related hot flashes and night sweats.

    Science.gov (United States)

    de Valois, Beverley A; Young, Teresa E; Robinson, Nicola; McCourt, Christine; Maher, Elizabeth J

    2010-10-01

    Women taking tamoxifen experience hot flashes and night sweats (HF&NS); acupuncture may offer a nonpharmaceutical method of management. This study explored whether traditional acupuncture (TA) could reduce HF&NS frequency, improve physical and emotional well-being, and improve perceptions of HF&NS. DESIGN/SETTINGS/LOCATION: This was a single-arm observational study using before and after measurements, located in a National Health Service cancer treatment center in southern England. Fifty (50) participants with early breast cancer completed eight TA treatments. Eligible women were ≥ 35 years old, ≥ 6 months post active cancer treatment, taking tamoxifen ≥ 6 months, and self-reporting ≥ 4 HF&NS incidents/24 hours for ≥ 3 months. Participants received weekly individualized TA treatment using a core standardized protocol for treating HF&NS in natural menopause. Hot Flash Diaries recorded HF&NS frequency over 14-day periods; the Women's Health Questionnaire (WHQ) assessed physical and emotional well-being; the Hot Flashes and Night Sweats Questionnaire (HFNSQ) assessed HF&NS as a problem. Measurements taken at five points over 30 weeks included baseline, midtreatment, end of treatment (EOT), and 4 and 18 weeks after EOT. Results for the primary outcome: Mean frequency reduced by 49.8% (95% confidence interval 40.5-56.5, p acupuncture to manage HF&NS, as well as research on nonhormonal pharmaceutical treatments. In addition to reduced HF&NS frequency, women enjoyed improved physical and emotional well-being, and few side-effects were reported. Further research is warranted into this approach, which offers breast cancer survivors choice in managing a chronic condition.

  11. A novel solar hot plate for cooking

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Mejia, Eduardo A; Osorio Jaramillo, Fidel A [Facultad de Ingenieria, UAEMex, Toluca, Edo. (Mexico)

    2000-07-01

    In Mexico and other developing countries, the use of firewood as combustible for cooking has contributed to deforestation and desertification of large zones. This is due to the lack of alternative combustibles for the poor inhabitants of the countryside and remote areas. In this paper, a new solar hot plate, intended for contributing to solve this problem, is presented. It can be used for cooking not only a great variety of prehispanic and traditional meals, like tortillas, fried meat and vegetables, but also hot cakes, bacon, eggs, steaks and fries. The hot plate solar cooker, called Tolocatzin, consists of a horizontal metallic plate, which is heated from both of its top and bottom surfaces by concentrated sun light from multicompound concentrator based on nonimaging optics, and built with nine ordinary plane glass-silvered, and two curved aluminum mirrors, so it can be manufactured easily in a small factory or at home. For an acceptance angle of 15 Celsius degrees, which allows the concentration of sun light without sun-tracking for about one hour, it can reach temperatures up to 240 Celsius degrees in a few minutes. This temperature is high enough for cooking almost all fried or grilled meals. The design was optimized using ray-trace procedures. The operational experience with early prototypes has shown that the Tolocatzin solar hot plate does an excellent cooking job and could really be massively used in sunny countries. [Spanish] En Mexico y otros paises en desarrollo, el uso de la madera como combustible para cocinar ha contribuido a la deforestacion y desertificacion de grandes zonas. Esto es debido a la falta de combustibles alternativos por parte de los habitantes pobres del campo y de areas remotas. En este articulo se presenta una nueva placa solar que tiene el proposito de contribuir a resolver este problema. Puede ser usada para cocinar no solamente una gran variedad de comidas prehispanicas y tradicionales, como tortillas, carne frita y verduras sino

  12. Hot flushes and night sweats symptom profiles over a 17-year period in mid-aged women: The role of hysterectomy with ovarian conservation.

    Science.gov (United States)

    Wilson, Louise F; Pandeya, Nirmala; Byles, Julie; Mishra, Gita D

    2016-09-01

    There is limited research on hot flushes and night sweats in women with a hysterectomy with ovarian conservation. We aimed to describe the patterns of these symptoms in a cohort of Australian women and to investigate the relationship between distinct symptom patterns and hysterectomy status. Repeated-measures latent class analysis (LCA) was used to identify hot flushes and night sweats symptom patterns across seven surveys (over 17 years) in the mid-cohort of the Australian Longitudinal Study on Women's Health. Multinomial logistic regression was used to assess the associations of the symptom patterns in women with a hysterectomy with ovarian conservation (n=1129) versus women without a hysterectomy (n=4977). A higher proportion of women with a hysterectomy than of those without experienced a constant pattern of hot flushes (15% versus 30%) and night sweats (9% versus 19%). Women with a hysterectomy had higher odds of constant hot flushes versus minimal hot flushes (OR=1.97, 95% CI: 1.64, 2.35) and constant versus minimal night sweats (OR=2.09, 95% CI: 1.70, 2.55). Smoking, a 'lower level of education to non-professional occupation' pathway and body mass index (BMI) patterns of 'always obese' and 'increasingly obese' were also associated with a higher risk of constant symptoms. Women who have a hysterectomy (with ovarian conservation) have a higher risk of hot flushes and night sweats that persist over an extended period. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Prediction of risk of depressive symptoms in menopausal women based on hot flash and sweating symptoms: a multicentre study

    Directory of Open Access Journals (Sweden)

    Zheng YW

    2017-11-01

    Full Text Available Yanwei Zheng,1 Yibei Zhou,1 Jiangshan Hu,1 Jieping Zhu,2 Qi Hua,3 Minfang Tao1 1Department of Gynecology and Obstetrics, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, 2Department of Gynecology and Obstetrics, Shanghai Sixth People’s Hospital East Branch, 3Department of Gynecology and Obstetrics, International Peace Maternal and Child Health Hospital of the China Welfare Institute, Shanghai, People’s Republic of China Objective: The present study aimed to develop a symptom-based (namely, hot flashes and sweating scoring system for predicting the risk of depressive symptoms in menopausal women via a multicentre cross-sectional survey. Methods: The data examined in the present study were obtained from 1,004 women aged 40–60 years who underwent physical examination at A Hospital. The basic information was obtained using a questionnaire-based survey. A self-rating depression scale was used to obtain the depressive symptom scores, while the Kupperman Menopausal Index was used to obtain the scores for the frequency of hot flashes and sweating. A logistic regression model was also established. The resulting β coefficient was employed to calculate and predict the risk of depressive symptoms in these women and a risk scoring system was established. The scoring system was validated using samples from 2 other centers (validation sample 1: B Hospital, 440 women; validation sample 2: C Hospital, 247 women. Results: The scoring system developed to predict the risk of depressive symptoms in menopausal women was based on hot flash and sweating symptoms and associated with menopausal status, hot flash scores, education level (high school education and below and being diabetic. The scoring system yielded a total score of 0–54 points. For women in the study sample, the area under the curve (AUC of depressive symptom risk score was 0.750 (95% CI, 0.708–0.793. Validation sample 1 had an AUC of 0.731 (95% CI, 0.667–0.794, while

  14. Sweating rates of dairy cows and beef heifers in hot conditions

    Science.gov (United States)

    Sweating rates from heat-stressed dairy and feedlot cows were measured using a “Portable Calorimeter” and a “Bovine Evaporation Meter” designed and fabricated for the studies reported herein. Measurements were taken when cows were in their natural habitat. The focus of the study was to compare swea...

  15. Cognitive-behavior therapy for menopausal symptoms (hot flushes and night sweats): moderators and mediators of treatment effects.

    Science.gov (United States)

    Norton, Sam; Chilcot, Joseph; Hunter, Myra S

    2014-06-01

    Cognitive-behavior therapy (CBT) has been found in recent randomized controlled trials (MENOS1 and MENOS2) to reduce the impact of hot flushes and night sweats (HFNS). In the MENOS2 trial, group CBT was found to be as effective as self-help CBT in reducing the impact of HFNS. This study investigates for whom and how CBT works for women in the MENOS2 trial. This study performed a secondary analysis of 140 women with problematic HFNS who were recruited to the MENOS2 trial: 48 were randomly assigned to group CBT, 47 were randomly assigned to self-help CBT, and 45 were randomly assigned to usual care. Self-report questionnaires were completed at baseline, 6 weeks postrandomization, and 26 weeks postrandomization. Potential moderators and mediators of treatment effects on the primary outcome-hot flush problem rating-were examined using linear mixed-effects models and path analysis, respectively. CBT was effective at reducing HFNS problem rating regardless of age, body mass index, menopause status, or psychological factors at baseline. Fully reading the manual in the self-help CBT arm and completing most homework assignments in the group CBT arm were related to greater improvement in problem rating at 6 weeks. The effect of CBT on HFNS problem rating was mediated by changes in cognitions (beliefs about coping/control of hot flushes, beliefs about night sweats and sleep) but not by changes in mood. These findings suggest that CBT is widely applicable for women having problematic HFNS, regardless of sociodemographic or health-related factors, and that CBT works mainly by changing the cognitive appraisal of HFNS.

  16. Treatment of Sweating, Hot Flushing and Sleep ‎Disturbance in Peri and Post Menopausal ‎Women with Oral Pometone

    Directory of Open Access Journals (Sweden)

    Milal Muhammad Al- Jeborry

    2017-12-01

    Full Text Available Vasomotor symptoms, such as hot flushes and night sweats, are very common during the menopausal transition. One of the important alternative treatments is foods or supplements enriched with phytoestrogens. Aim of the study To assess the efficacy, safety and acceptability of pometone supplements for reducing sweating, hot flushes and sleep disturbance in peri and postmenopausal women. Methods This cross sectional randomized clinical therapeutic trail involved 44 peri and postmenopausal women. All patients took oral pometone capsule 500mg twice daily for one month period. Result The mean of hot flush, sweating score before treatment was 8.11±1.72. After four weeks of treatment, it became 1.36 ±2.10; P value was < 0.0001. The mean of sleep disturbance score before treatment was 4.40±3.03. After four weeks of treatment, it become 1.22 ±1.80 ; P value was  < 0.0001 . No side effect was reported during the course of this study. Conclusion Pometone is effective, safe and cheep treatment to reduce hot flushes , night sweat and sleep disturbance in peri and postmenopausal women

  17. What's Sweat?

    Science.gov (United States)

    ... Weight for Me? Your Teeth Heart Murmurs What's Sweat? KidsHealth > For Kids > What's Sweat? Print A A ... dehydrated (say: dee-HI-drayt-ed). Why Does Sweat Smell? Sweat isn't just wet — it can ...

  18. Sweat fluid and ion losses in horses during training and competition in cool vs. hot ambient conditions: implications for ion supplementation.

    Science.gov (United States)

    McCutcheon, L J; Geor, R J

    1996-07-01

    The objectives of this study were to: 1) determine incremental and total sweat fluid and ion losses during and following (a) exercise training and (b) a treadmill Speed and Endurance exercise test (SEET) which simulated running speeds and distances required for each phase of an Olympic level (CCI****) 3-day-event in cool and hot ambient conditions and 2) determine the requirement for ion supplementation based on the calculated ion losses associated with these activities. Six exercise-trained Thoroughbred horses completed 2 weeks of exercise training in each of 2 ambient conditions: cool, dry (CD, room temperature [T] = 20-22 degrees C, relative humidity [RH] = 45-55%), or hot and humid (HH, T = 33-35 degrees C, RH = 80-85%). Following the 2 week period of training in either CD or HH conditions, horses completed a SEET under similar conditions (either CD, or hot and dry (HD, T = 33-35 degrees C, RH = 45-55%). Sweating rate and sweat ion composition for each 5 min interval was determined from sweat samples collected from a sealed pouch attached to the lateral thorax. Total sweat fluid losses during training in the heat were 2- or 3-fold greater when compared to CD. Similarly, sweat fluid losses associated with the SEET in HD were almost double (19.2 litres) the losses in CD (11.7 litres). Total calculated ion losses associated with 2 h of training in HH (3724 mmol; 115.2 g) were significantly greater when compared to CD (1413 mmol; 43.5 g). Following the SEET and a 30 min recovery period, total ion losses in CD were 3636 mmol (112.2 g) compared with 6519 mmol (200.6 g) in HD. The differences in ion losses represent the increased sweating rates stimulated by higher core temperatures during moderate to high intensity exercise in warmer ambient conditions and increases in sweat ion concentrations associated with higher sweating rates. Extracellular fluid (ECF) ion losses during daily exercise training and the SEET were also calculated from changes in plasma ion

  19. Hot-rolled Process of Multilayered Composite Metal Plate

    Directory of Open Access Journals (Sweden)

    YU Wei

    2017-02-01

    Full Text Available For multi-layer plate, it is a difficult problem to increase product yield rate and improve bonding interface quality. A high yield hot-rolled method of multilayered plate was proposed. The raw strips and plate were fixed by argon arc welding. The combined billet was put into a metal box and vacuum pumped, and then heated and rolled by multi passes at the temperature of 1000-1200℃. The 67 layered plate with the thickness of 2.5mm was successfully produced. The interfacial microstructures and diffusion behavior were investigated and analyzed by optical microscopy and scan electronic microscopy. The tensile and shear strength were tested,and the shear fractures were analyzed. The results show that the multilayered plate yield rate is more than 90% by two steps billet combination method and rolling process optimization. The good bonding interface quality is obtained, the shear strength of multilayered plate reaches 241 MPa. Nickel interlayer between 9Cr18 and 1Cr17 can not only prevent the diffusion of carbon, but also improve the microstructure characteristics.

  20. Night Sweats

    Science.gov (United States)

    Symptoms Night sweats By Mayo Clinic Staff Night sweats are repeated episodes of extreme perspiration that may soak your nightclothes or ... these episodes are usually not labeled as night sweats and typically aren't a sign of a ...

  1. Hot Flushes and Night Sweats in Midlife: Why do Some Women Have Them and Others do Not?

    Directory of Open Access Journals (Sweden)

    Filipa Pimenta

    2015-12-01

    Full Text Available AbstractThis study investigated what predicts the occurrence of hot flushes (HF and night sweats (NS. A community sample of 992 women (42-60 years answered a questionnaire to collect socio-demographic, health and menopause-related, as well as lifestyle information. Depressive mood and stress, as well as HF and NS (in terms of presence, frequency and intensity, were also assessed. Structural equation modelling was used to build a structural model to predict the occurrence of both vasomotor symptoms. Results: Stress predicted NS (β =.154; p=.006, whereas depressive mood was linked to the occurrence of HF's (β =.149; p=.006. Being peri-menopausal and post-menopausal, among several other characteristics, were also significant predictors of the occurrence of both HF and NS. This study supports a distinguished influence of stress and depressive mood in NS and HF respectively, probably due to the nature of psychological symptoms. Moreover, significant associations between vasomotor symptoms and socio-demographic, health and menopause-related characteristics, and alcohol were confirmed.

  2. Regenerating silicon biosensors through thermal ablation with a hot plate

    Directory of Open Access Journals (Sweden)

    Stephane Leahy

    2015-12-01

    Full Text Available Biosensor development is time-consuming and expensive because it requires a great deal of prototyping and specialized experimental testing using, in many cases, one-time use chips. Several biosensor regeneration techniques have been proposed so that chips may be reused, but these techniques are not convenient for rapid prototyping and experimental testing. A convenient biosensor regeneration technique using thermal ablation with a hot plate is presented. Bound biological material is removed from a Poly-L-Lysine-functionalized silicon biosensor used for testing Escherichia coli by heating the biosensor to 370 °C for 10 min. Images and resonant frequency shifts indicate that regeneration is about 82% effective. This regeneration technique may be further improved by using a higher heating rate and a higher temperature.

  3. Sweat Therapy.

    Science.gov (United States)

    Colmant, Stephen A.; Merta, Rod J.

    2000-01-01

    A study combined group sweating and group counseling. Four adolescent boys with disruptive behavior disorders participated in 12 sweat therapy sessions. They reported the sessions useful for sharing personal concerns and receiving assistance with problem solving. Three boys showed improvement in self-esteem. Advantages of sweat therapy over other…

  4. The solar hot-plates called Tolokatsin II; El nuevo comal solar Tolokatsin II

    Energy Technology Data Exchange (ETDEWEB)

    Rincon, M. E.; Osorio, J. F.; Velasco, O. E.

    2004-07-01

    An advanced version of the solar hot-plates called Tolokatsin is presented in this paper. The original hot plate solar cooker consists of a metallic or ceramic horizontal plate which is heated from both of its top and bottom surfaces by concentrated sun light from a multi compound concentrator based on non-imaging optics and built with nine ordinary plane glass-silvered and two curved aluminium mirrors, so it can be manufactured easily in a small factory or at home. This design allows temperatures of 140 degree Celsius in a few minutes. This temperature is high enough for cooking almost all fried or grilled meals. The Tolokatsin solar hot plates do an excellent cooking job, but its performance can be improved placing 2 flat and 2 curved mirrors more, and 2 simple wedge-shaped lenses whose function are described here. (Author)

  5. Numerical simulation of springback of medium-thick plates in local hot rolling

    Directory of Open Access Journals (Sweden)

    XIE Dong

    2017-10-01

    Full Text Available [Objectives] In order to understand the factors of springback in the local hot rolling of medium-thick steel plates,[Methods] a 3D thermal-elastic-plastic analysis is conducted to investigate the factors affecting the amount of springback. Through a series of numerical analyses,the influence of deformation temperature,temperature field distribution,plate size and local loading are examined. [Results] The results show that when the deformation temperature exceeds a certain level at which material yield stress begins to decrease significantly,the springback will reduce markedly with the increase in temperature. Due to the distribution characteristics of the deformation area,the influence of temperature distribution on springback where the local deformation scale is larger is dominated by the three dimensions of temperature field distribution. Changes in the length and width of the plate have a certain influence on the springback,in which changes to the length of a plate where the local deformation scale is larger have a more obvious influence on springback. The springback of the plate decreases with the increase of local loading. [Conclusions] The results of this study can assist in the optimization of parameters in the automatic hot rolling of thick plates,while also having a basic guiding effect on the further study of springback in the local hot rolling of thick plates.

  6. Sweat Allergy.

    Science.gov (United States)

    Hiragun, Takaaki; Hide, Michihiro

    2016-01-01

    For many years, sweat has been recognized as an exacerbation factor in all age groups of atopic dermatitis (AD) and a trigger of cholinergic urticaria (CholU). Recently, we reported the improvement of AD symptoms by spray with tannic acid, which suppresses basophil histamine release by semipurified sweat antigens in vitro, and showering that removes antigens in sweat from the skin surface. We finally identified MGL_1304 secreted by Malassezia globosa as a major histamine-releasing antigen in human sweat. MGL_1304 is detected as a 17-kDa protein in sweat and exhibits almost the highest histamine-release ability from basophils of patients with AD and CholU among antigens derived from Malassezia species. Moreover, serum levels of anti-MGL_1304 IgE of patients with AD and CholU were significantly higher than those of normal controls. Desensitization therapy using autologous sweat or MGL_1304 purified from culture of M. globosa or its cognates might be beneficial for patients with intractable CholU due to sweat allergy. © 2016 S. Karger AG, Basel.

  7. The Simulation of the Influence of Water Remnants on a Hot Rolled Plate after Cooling

    Directory of Open Access Journals (Sweden)

    Radek Zahradník

    2012-01-01

    Full Text Available In situations when a sheet metal plate of large dimensions is rolled, water remnants from cooling can be observed on the upper side of the plate. This paper focuses on deformations of a hot rolled sheet metal plate that are caused by water remnants after cooling. A transient finite element simulation was used to describe shape deformations of the cross profile of a metal sheet. The finite element model is fully parametric for easy simulation of multiple cases. The results from previous work were used for the boundary conditions.

  8. Thermal simulation of surface micromachined polysilicon hot plates of low power consumption

    NARCIS (Netherlands)

    Dumitrescu, Marius; Cobianu, Cornel; Lungu, Dan; Pascu, Adrian; Kolev, Spas; van den Berg, Albert

    1999-01-01

    A simple, IC compatible, surface micromachined polysilicon membrane was technologically designed and thermally simulated by 3D finite element ‘COSMOS' program in order to investigate its capability to work as a micro hot plate for a gas sensing test structure of low power consumption. For an

  9. Hot flushes

    African Journals Online (AJOL)

    without thermoregulatory homeostatic mechanisms, such as sweating, being triggered. Small fluctuations in core body. Abstract. Vasomotor symptoms, such as hot flushes and night sweats, are considered to be the cardinal symptoms of menopause, and are experienced by most women. The physiology of hot flushes is not ...

  10. Sweat electrolytes test

    Science.gov (United States)

    Sweat test; Sweat chloride; Iontophoretic sweat test; CF - sweat test; Cystic fibrosis - sweat test ... A colorless, odorless chemical that causes sweating is applied to a small area on an arm or leg. An electrode is then attached to the spot. A weak electrical ...

  11. Sweat composition in exercise and in heat.

    Science.gov (United States)

    Verde, T; Shephard, R J; Corey, P; Moore, R

    1982-12-01

    Sweat samples were collected from the forearms of eight male volunteers using light gauze pads applied for 20-min periods. Preliminary trials indicated that this technique yielded realistic figures for both sweat volume and sweat composition. Tests were conducted under three conditions: a) outdoor exercise, cool environment; b) indoor exercise, normal room temperatures; and c) sauna exposure. In all environments, proximal forearm samples indicated a larger sweat secretion than distal forearm or hand samples. [Mg2+] decreased as sweat flow increased, but after allowance for interindividual differences of sweat volume, [Na+], [K+], [Ca2+], and [Cl-] were independent of sweat flow rates. The differential effect of sweat flow suggests active regulation rather than contamination. Interindividual differences of sweat composition could not be explained in terms of differences in personal fitness. Sauna bathing yielded sweat with a higher [Mg2+] and [Ca2+] content than did exercise; however, [Na+], [K+], and [Cl-] were similar for the three experimental conditions. Again, the data are best explained in terms of an active regulation of sweat composition. Total ionic losses do not seem sufficient to deplete body mineral reserves unless many days of training are undertaken in a hot climate.

  12. Experimental Study of Water Jet Impingement Cooling of Hot Steel Plates

    OpenAIRE

    Karwa, Nitin

    2012-01-01

    Liquid jet impingement cooling is critical in many industrial applications. Principle applications include extracting large heat flux from metal parts, such as hot fuel bundle post-loss-of-coolant-accident in nuclear reactors, heat treatment of steel plates post-hot-processing, etc. The ability of liquid jets to extract high heat flux at controlled rates from metal parts, with temperatures as high as 800-1000 ºC, at moderate flow rates has made them indispensable in these applications. Due to...

  13. Sweating Like a Pig: Physics or Irony?

    Science.gov (United States)

    Bohren, Craig F.

    2016-01-01

    In his interesting and informative book "Is That a Fact?," Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on…

  14. A hot plate solar cooker with electricity generation-Combining a parabolic trough mirror with a sidney tube and heat pipe

    NARCIS (Netherlands)

    Kaasjager, A.D.J.; Moeys, G.P.G.

    2012-01-01

    Solar cookers supply clean and sustainable energy for cooking and so limit the use of wood or charcoal. A new type of solar cooker is developed with a hot plate. The hot plate offers comfortable access to the food under preparation. The hot plate opens up the opportunity to generate small amounts of

  15. Laser-multi-pass-narrow-gap-welding of hot crack sensitive thick aluminum plates

    OpenAIRE

    Dittrich, D.; Schedewy, R.; Brenner, B.; Standfuß, J.

    2013-01-01

    Although the current process limitations for laser beam welding of thick aluminum plates (>10 mm) have been overcome by high brilliant multi-kilowatt laser, there are still difficulties resulting from the material physical properties, e.g. the high heat conductivity, the large heat capacity and the high thermal expansion coefficient of aluminum. Especially for very deep weld seams, insufficient dilution of filler wire material in the root of the weld seam and the danger of hot cracks increase...

  16. Design and construction of a guarded hot plate apparatus operating down to liquid nitrogen temperature.

    Science.gov (United States)

    Li, Manfeng; Zhang, Hua; Ju, Yonglin

    2012-07-01

    A double-sided guarded hot plate apparatus (GHP) is specifically designed, fabricated, and constructed for the measurement of thermal conductivities of insulation specimens operated down to liquid nitrogen temperature (-196 °C), at different controlled pressures from 0.005 Pa to 0.105 MPa. The specimens placed in this apparatus are 300 mm in diameter at various thicknesses ranging from 4 mm to 40 mm. The apparatus is different from traditional GHP in terms of structure, supporting and heating method. The details of the design and construction of the hot plate, the cold plates, the suspensions, the clampings, and the vacuum chamber of the system are presented. The measurement methods of the temperatures, the input power, the meter area, and the thickness of the specimens are given. The apparatus is calibrated with teflon plates as sample and the maximum deviation from the published data is about 6% for thermal conductivity. The uncertainties for the measurement are also discussed in this paper.

  17. Investigation of Hot Rolling Influence on the Explosive-Welded Clad Plate

    Directory of Open Access Journals (Sweden)

    Guanghui ZHAO

    2016-11-01

    Full Text Available The microstructure, the shear strength and tensile strength of stainless steel explosive-welded clad plate at different rolling reduction were studied. The mechanical properties of the explosive-welded and explosive-rolled clad plates were experimentally measured. Simultaneously, the microstructures of the clad plate were investigated by the Ultra deep microscope and the tensile fracture surface were observed by the scan electron microscope (SEM. It was observed that the tensile strength has been increased considerably, whereas the elongation percentage has been reduced with the increase of hot rolling reduction. In the tensile shear test, the bond strength is higher than the strength of the ferritic stainless steel layer and meets the relevant known standard criterion. Microstructural evaluations showed that the grain of the stainless steel and steel refined with the increase of thickness reduction. Examination of the tensile fracture surfaces reveal that, after hot rolling, the fracture in the low alloy steel and ferritic stainless steel clad plates is of the ductile type.DOI: http://dx.doi.org/10.5755/j01.ms.22.4.12409

  18. Precipitation Strengthening by Induction Treatment in High Strength Low Carbon Microalloyed Hot-Rolled Plates

    Science.gov (United States)

    Larzabal, G.; Isasti, N.; Rodriguez-Ibabe, J. M.; Uranga, P.

    2018-01-01

    The use of microalloyed steels in the production of thick plates is expanding due to the possibility of achieving attractive combinations of strength and toughness. As market requirements for high strength plates are increasing and new applications require reduced weight and innovative designs, novel approaches to attaining cost-effective grades are being developed. The mechanism of precipitation strengthening has been widely used in thin strip products, since the optimization of the coiling strategy offers interesting combinations in terms of final properties and microalloying additions. Precipitation strengthening in thick plates, however, is less widespread due to the limitation of interphase precipitation during continuous cooling after hot rolling. With the main objective of exploring the limits of this strengthening mechanism, laboratory thermomechanical simulations that reproduced plate hot rolling mill conditions were performed using low carbon steels microalloyed with Nb, NbMo, and TiMo additions. After continuous cooling to room temperature, a set of heat treatments using fast heating rates were applied simulating the conditions of induction heat treatments. An important increase of both yield and tensile strengths was measured after induction treatment without any important impairment in toughness properties. A significant precipitation hardening is observed in Mo-containing grades under specific heat treatment parameters.

  19. Changes in the index of sweat ion concentration with increasing sweat during passive heat stress in humans.

    Science.gov (United States)

    Shamsuddin, A K M; Yanagimoto, S; Kuwahara, T; Zhang, Y; Nomura, C; Kondo, N

    2005-06-01

    To investigate the pattern changes in the index of sweat ion concentration at skin surface with increasing sweat during passive heat stress in humans, we measured conductivity of the perfused water with sweat as the index of sweat ion concentration and sweat rate, continuously at the chest skin surface. Eight healthy subjects (22.4 +/-1.0 years) were passively heated by lower-leg immersion in a hot water bath of 42 degrees C for 50 min in an ambient temperature of 28 degrees C and relative humidity of 50%. The internal temperature (Tor) thresholds of sweat rate and index of sweat ion concentration were almost similar. Concomitant onset for the index of sweat ion concentration and sweat rate occurred but two types of linear regression lines were identified in the relationship between the index of sweat ion concentration and sweat rate at a boundary sweat rate value of 0.30 +/- 0.08 mg cm(-2) min(-1). The slope of the regression line at low levels of sweat (slope 0.02 +/- 0.01 V mg(-1) cm(-2) min(-1)) was significantly gradual compared with that at moderate levels of sweat (slope 0.30 +/- 0.08 V mg(-1) cm(-2) min(-1)) (P<0.05). These results suggest that at low levels of sweat the index of sweat ion concentration responds gradually with respect to sweat rate, which may be due to the ion reabsorption capacity of the sweat duct, and then the index of sweat ion concentration increased steeply with sweat rate.

  20. Hot Isostatic Press Manufacturing Process Development for Fabrication of RERTR Monolithic Fuel Plates

    Energy Technology Data Exchange (ETDEWEB)

    Crapps, Justin M. [Los Alamos National Laboratory; Clarke, Kester D. [Los Alamos National Laboratory; Katz, Joel D. [Los Alamos National Laboratory; Alexander, David J. [Los Alamos National Laboratory; Aikin, Beverly [Los Alamos National Laboratory; Vargas, Victor D. [Los Alamos National Laboratory; Montalvo, Joel D. [Los Alamos National Laboratory; Dombrowski, David E. [Los Alamos National Laboratory; Mihaila, Bogdan [Los Alamos National Laboratory

    2012-06-06

    We use experimentation and finite element modeling to study a Hot Isostatic Press (HIP) manufacturing process for U-10Mo Monolithic Fuel Plates. Finite element simulations are used to identify the material properties affecting the process and improve the process geometry. Accounting for the high temperature material properties and plasticity is important to obtain qualitative agreement between model and experimental results. The model allows us to improve the process geometry and provide guidance on selection of material and finish conditions for the process strongbacks. We conclude that the HIP can must be fully filled to provide uniform normal stress across the bonding interface.

  1. Thermal response simulation for tuning PID controllers in a 1016 mm guarded hot plate apparatus.

    Science.gov (United States)

    Thomas, William C; Zarr, Robert R

    2011-07-01

    A mathematical model has been developed and used to simulate the controlled thermal performance of a large guarded hot-plate apparatus. This highly specialized apparatus comprises three interdependent components whose temperatures are closely controlled in order to measure the thermal conductivity of insulation materials. The simulation model was used to investigate control strategies and derive controller gain parameters that are directly transferable to the actual instrument. The simulations take orders-of-magnitude less time to carry out when compared to traditional tuning methods based on operating the actual apparatus. The control system consists primarily of a PC-based PID control algorithm that regulates the output voltage of programmable power amplifiers. Feedback parameters in the form of controller gains are required for the three heating circuits. An objective is to determine an improved set of gains that meet temperature control criteria for testing insulation materials of interest. The analytical model is based on aggregated thermal capacity representations of the primary components and includes the same control algorithm as used in the actual hot-plate apparatus. The model, accounting for both thermal characteristics and temperature control, was validated by comparisons with test data. The tuning methodology used with the simulation model is described and results are presented. The resulting control algorithm and gain parameters have been used in the actual apparatus without modification during several years of testing materials over wide ranges of thermal conductivity, thickness, and insulation resistance values. Published by Elsevier Ltd on behalf of ISA.

  2. Design Guideline for New Generation of High-Temperature Guarded Hot Plate

    Science.gov (United States)

    Wu, J.; Hameury, J.; Failleau, G.; Blahut, A.; Vachova, T.; Strnad, R.; Krause, M.; Rafeld, E.; Hammerschmidt, U.

    2018-02-01

    This paper complements the existing measurement standards and literature for high-temperature guarded hot plates (HTGHPs) by addressing specific issues relating to thermal conductivity measurement of technical insulation at high temperatures. The examples given are focused on the designs of HTGHPs for measuring thin thermal insulation. The sensitivity studies have been carried out on major influencing factors that affect the thermal conductivity measurements using HTGHPs, e.g., the uncertainty of temperature measurements, plate flatness and center-guard gap design and imbalance. A new configuration of center-guard gap with triangular shape cross section has been optimized to obtain the same thermal resistance as a 2 mm wide gap with rectangular shape cross section that has been used in the HTGHPs at NPL and LNE. Recommendations have been made on the selections of heater plate materials, high-temperature high-emissivity coatings and miniature temperature sensors. For the first time, thermal stress analysis method has been applied to the field of HTGHPs, in order to estimate the effect of differential thermal expansion on the flatness of thin rigid specimens during thermal conductivity tests in a GHP.

  3. Formula study for plate heat exchanger in the central heating regulation of the indirect connection hot water heating system

    Directory of Open Access Journals (Sweden)

    Minghui CUI

    2016-10-01

    Full Text Available Plate heat exchanger has unique advantages and becomes dominant heat exchange equipment in heating engineering, but there is no heating regulation formula of plate exchanger applied in central heating regulation of indirect connection hot water heating. This paper analyzes the condition that the heating user's system adopts quality regulation method and the hot water network system adopts quality-flow regulation method, and obtains the regulation formulas of plate exchanger applied in central heating regulation of indirect connection hot water heating used for the above two systems. Empirical calculation shows that the formula can be applied to the quality regulation and the mass flow regulation of the different flow optimization adjustment coefficient, and it is an all-round formula.

  4. Antinociceptive effects of voluntarily ingested buprenorphine in the hot-plate test in laboratory rats

    DEFF Research Database (Denmark)

    Kristensen, Sara Hestehave; Munro, Gordon; Brønnum Pedersen, Tina

    2017-01-01

    . In addition, it is desirable to provide post-operative analgesia using methods that are minimally invasive and stressful. This study investigated the antinociceptive effects of orally administered buprenorphine ingested in Nutella® in comparison with subcutaneous buprenorphine administration. By exposing...... the animal to a thermal stimulus using a hot plate, significant antinociceptive effects of voluntarily ingested buprenorphine administered in Nutella® were demonstrated. This was evident at doses of 1.0 mg/kg 60 and 120 min post administration (P... as with subcutaneous administration, and had a later onset. It is advised to administer the oral formulation of buprenorphine in Nutella® in a 10-fold higher dose, as well as approximately 60 min earlier, than with the more commonly employed subcutaneous route of administration....

  5. Is the Juan Fernandez Ridge (nazca Plate) a Deep-Mantle Hot SPOT Trail?

    Science.gov (United States)

    Lara, L. E.; Selles, D.; Díaz, A.; Piña-Gauthier, M.

    2011-12-01

    The Juan Fernández Ridge on the oceanic Nazca plate is thought to be a classic hot spot trail because of the apparent westward rejuvenation of the eruptive ages. Geochronological data is still scarce to prove this is the case, and other hypothesis should be taken into account. There are a few constrains, like the ca. 9 Ma Ar-Ar age of the O'Higgins seamount (115 km from the Chile-Perú trench), published K-Ar ages of ca. 3-4 Ma in Robinson Crusoe island (580 km from the trench) and ca. 1 Ma in Alejandro Selkirk (180 km further west). New reconnaissance K-Ar ages in Robinson Crusoe yield ca. 1-3 Ma, which partially overlap with the age of Alejandro Selkirk, breaking the expected age progression given that the Nazca plate moves eastwards at ca. 6-8 cm/yr. New geological mapping also shows a sharp unconformity between the older, strongly altered sequences and more recent, post-erosional volcanic piles, where only the vent facies have disappeared. A fixed deep-mantle plume origin for Pacific hot spots has been widely debated and concurrent phenomena arose as a possible explanation for non-linear age progressions and/or long-lived volcanic activity. In fact, intraplate regional tectonics, plume displacement, and mantle heterogeneities could be the main factor of the ridge architecture or the mask for a first-order linear trend. An ongoing mapping and dating effort is aimed to understand the evolution of the Juan Fernández Ridge, testing the main hypothesis. Fondecyt grant 110966 is acknowledged for financial support.

  6. Hot Plate Method with Two Simultaneous Temperature Measurements for Thermal Characterization of Building Materials

    Science.gov (United States)

    Osséni, Sibiath O. G.; Ahouannou, Clément; Sanya, Emile A.; Jannot, Yves

    2017-07-01

    This paper presents a study of the hot plate method with two simultaneous temperature measurements, on the heated and unheated faces of a sample to characterize. The thermal properties of polyvinyl chloride, plaster and laterite were considered to be a representative range of building materials. A 1D quadrupolar model was developed to represent the temperature evolution on the two faces over time. Three-dimensional numerical modeling of a quarter of the testing device with COMSOL software allowed defining the domain of the 1D hypothesis validity. The analysis of estimation possibilities of materials' thermal characteristics, with the developed method, revealed that thermal effusivity can be accurately estimated by using the temperature of the heated face at the beginning of heating. We showed that the simultaneous use of two temperatures enables the estimation of the thermal conductivity with a greater accuracy and over a shorter time interval than using the temperature of the heated face alone. We also demonstrated that under certain conditions (samples with a high ratio of thickness to width) the method with two temperature measurements enabled the estimation of the thermal effusivity and conductivity, while the method with one temperature allowed only the thermal effusivity to be estimated, because of 3D effects. This conclusion was confirmed by experimental results obtained with a mortar sample.

  7. The Study of Analgesic Effects of Leonurus cardiaca L. in Mice by Formalin, Tail Flick and Hot Plate Tests.

    Science.gov (United States)

    Rezaee-Asl, Masoume; Sabour, Mandana; Nikoui, Vahid; Ostadhadi, Sattar; Bakhtiarian, Azam

    2014-01-01

    Leonurus cardiaca, commonly known as motherwort, is a member of the Lamiaceae family. It has a number of interesting biological activities, for example, sedative and hypotensive, antioxidant, anti-inflammatory, and antimicrobial activities. The aim of the present study was to investigate the effect of alcoholic extract of aerial part of Leonurus cardiaca on nociceptive response using formalin, tail flick, and hot plate tests in mice. The acute treatment of mice with an ethanolic extract at doses of 500 and 250 mg/kg by intraperitoneal administration produced a significant antinociceptive in the first and second phases of formalin test, respectively. The hot plate and tail flick tests showed an increase in the antinociceptive effect at dose 500 mg/kg. These results suggest that Leonurus cardiaca possesses central and peripheral antinociceptive actions.

  8. Normative data for regional sweat sodium concentration and whole-body sweating rate in athletes.

    Science.gov (United States)

    Baker, Lindsay B; Barnes, Kelly A; Anderson, Melissa L; Passe, Dennis H; Stofan, John R

    2016-01-01

    The purpose of this study was to establish normative data for regional sweat sodium concentration ([Na+]) and whole-body sweating rate in athletes. Data from 506 athletes (367 adults, 139 youth; 404 male, 102 female) were compiled from observational athlete testing for a retrospective analysis. The participants were skill/team-sport (including American football, baseball, basketball, soccer and tennis) and endurance (including cycling, running and triathlon) athletes exercising in cool to hot environmental conditions (15-50 °C) during training or competition in the laboratory or field. A standardised regional absorbent patch technique was used to determine sweat [Na+] on the dorsal mid-forearm. Whole-body sweat [Na+] was predicted using a published regression equation (y = 0.57x+11.05). Whole-body sweating rate was calculated from pre- to post-exercise change in body mass, corrected for fluid/food intake (ad libitum) and urine output. Data are expressed as mean ± SD (range). Forearm sweat [Na+] and predicted whole-body sweat [Na+] were 43.6 ± 18.2 (12.6-104.8) mmol · L(-1) and 35.9 ± 10.4 (18.2-70.8) mmol · L(-1), respectively. Absolute and relative whole-body sweating rates were 1.21 ± 0.68 (0.26-5.73) L · h(-1) and 15.3 ± 6.8 (3.3-69.7) ml · kg(-1) · h(-1), respectively. This retrospective analysis provides normative data for athletes' forearm and predicted whole-body sweat [Na+] as well as absolute and relative whole-body sweating rate across a range of sports and environmental conditions.

  9. Correction on the influence of thermal contact resistance in thermal conductivity measurements using the guarded hot plate method

    Directory of Open Access Journals (Sweden)

    Stepanić Nenad

    2009-01-01

    Full Text Available This work considers the influence of finite thermal contact resistances which exist in thermal conductivity measurements of homogeneous and poor thermal conductive materials using the guarded hot plate method. As an example of correction method proposed in this work, different experimental results obtained from a standard reference material sample (with the conductivity of about 1 W/mK have been presented.

  10. Sweating Like a Pig: Physics or Irony?

    Science.gov (United States)

    Bohren, Craig F.

    2016-03-01

    In his interesting and informative book Is That a Fact?, Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on the "pig." But this explanation, which I have seen on the Internet, lacks a few caveats. It implies that molten iron, solidifying and cooling, anywhere, anytime, accretes liquid water, as if this were a special property of cooling iron. Set aside that real pigs sweat perceptibly from their snouts; kiss a pig and verify for yourself. Pigs also sweat imperceptibly. Imperceptible (insensible) perspiration is water vapor from the skin and lungs exuded without sensible condensation. That from humans is about 1 liter/day. Sweat is 99% liquid water, NaCl the dominant solute, secreted quickly, sometimes profusely, by subcutaneous sweat glands in response to thermal stress, in contrast to the slow, continuous diffusion of water vapor through skin.

  11. A development of the method of the control signal formation for the hot plate mill automation systems to improve the flatness of the finish plate

    Directory of Open Access Journals (Sweden)

    Voronin Stanislav S.

    2016-01-01

    Full Text Available This article describes how to control of the hot plate mill automation system to improve the quality metrics if the final strip. Based on the data of the modern hot rolling mills the classification of the cage equipment was designed. Depending on the degree of influence on the magnitude of reduction, the equipment was divided into categories. The functioning of every system including the main and the vertical cages was described. The conditions of electrical and hydraulic mechanisms was marked. The developed algorithm allows to improve defects based on the finite number of the thickness measurements given by special non-contact sensors. The example of regulators signals calculating was shown. The result of the algorithm operating was illustrated.

  12. Efficient sweat reduction of three different antiperspirant application forms during stress-induced sweating.

    Science.gov (United States)

    Schmidt-Rose, T; Lehmbeck, F; Bürger, A; Windisch, B; Keyhani, R; Max, H

    2013-12-01

    Stress sweating can occur in everyday situations independently of thermally-induced perspiration. It is triggered by emotionally challenging situations and leads to underarm wetness and a characteristic unpleasant malodor. In this study, we aimed to determine the long-term efficacy of three unperfumed antiperspirant (AP) formulas for different application forms (roll-on, stick, aerosol) against stress-induced sweating and malodor formation. We utilized the widely accepted Trier Social Stress Test (TSST) to induce psychosocial stress in female and male volunteers (18 - 40 years) and determined physiological stress parameters. To additionally assess the efficacy of the test AP roll-on against thermally-induced sweating, a hot room study was performed. Increasing heart rates and an augmentation of saliva cortisol levels during the TSST indicated a substantial stress reaction which was paralleled by a pronounced sweat production in the untreated axillae of both males and females. Forty-eight hours after application, all three test APs significantly decreased the amount of sweat in the treated axillae independent of gender. With respect to AP effects on malodor production, trained sniffers assessed sweat samples collected during the TSST from the untreated axillae as significantly more malodorous than comparable samples from the AP-treated axillae. Also, independent of gender the test AP roll-on significantly decreased the thermally-induced sweat in the AP-treated axilla. We show for the first time a highly effective reduction of emotionally-induced axillary sweating and malodor production for three different application forms 48 h after the last product use. The specially developed roll-on, stick, and aerosol AP provide long-term protection against stress-induced sweat which is of high relevance in everyday life. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  13. Eccrine sweat gland development and sweat secretion.

    Science.gov (United States)

    Cui, Chang-Yi; Schlessinger, David

    2015-09-01

    Eccrine sweat glands help to maintain homoeostasis, primarily by stabilizing body temperature. Derived from embryonic ectoderm, millions of eccrine glands are distributed across human skin and secrete litres of sweat per day. Their easy accessibility has facilitated the start of analyses of their development and function. Mouse genetic models find sweat gland development regulated sequentially by Wnt, Eda and Shh pathways, although precise subpathways and additional regulators require further elucidation. Mature glands have two secretory cell types, clear and dark cells, whose comparative development and functional interactions remain largely unknown. Clear cells have long been known as the major secretory cells, but recent studies suggest that dark cells are also indispensable for sweat secretion. Dark cell-specific Foxa1 expression was shown to regulate a Ca(2+) -dependent Best2 anion channel that is the candidate driver for the required ion currents. Overall, it was shown that cholinergic impulses trigger sweat secretion in mature glands through second messengers - for example InsP3 and Ca(2+) - and downstream ion channels/transporters in the framework of a Na(+) -K(+) -Cl(-) cotransporter model. Notably, the microenvironment surrounding secretory cells, including acid-base balance, was implicated to be important for proper sweat secretion, which requires further clarification. Furthermore, multiple ion channels have been shown to be expressed in clear and dark cells, but the degree to which various ion channels function redundantly or indispensably also remains to be determined. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  14. Sweating rate and sweat composition during exercise and recovery in ambient heat and humidity.

    Science.gov (United States)

    McCutcheon, L J; Geor, R J; Hare, M J; Ecker, G L; Lindinger, M I

    1995-11-01

    The objective of this study was to determine the composition and extent of sweat losses during submaximal exercise under hot and humid conditions and to compare these findings with the same exercise protocol conducted under cool, dry and hot, dry conditions. Five Thoroughbred horses (age 3 to 6) completed exercise tests under each of 3 environmental conditions in random order: cool, dry (CD), room temperature (T) = 20 degrees C, relative humidity (RH) = 45-55%; hot, dry (HD), T = 32-34 degrees C, RH = 45-55%; and hot, humid (HH), T = 32-34 degrees C, RH = 80-85%. Horses exercised at 50% of their predetermined VO2max on a treadmill set at a 10% slope until attainment of a pulmonary artery blood temperature of 41.5 degrees C followed by a 60 min recovery. Sweat was collected from a sealed polyethylene pouch enclosing a 150 cm2 area on the lateral thorax. During exercise and the first 30 min of recovery, sweat fluid losses were 7.9 +/- 0.7 litres, 9.9 +/- 0.5 litres and 6.6 +/- 1.2 litres (mean +/- s.e.m.) for CD, HD and HH, respectively. Sweating rate (SR), calculated from sweat volume per unit area of enclosed skin, was lowest in CD and similar in HD and HH during exercise such that at end of exercise in HH (16.5 min) calculated sweat losses were approximately 5% and 32% higher than in HD and CD, respectively. In recovery, SR declined in all conditions but was significantly lower in CD (P Sweating was detectable until 30 min recovery in CD, 45 min recovery in HD and 60 min recovery in HH. Sweat composition and osmolality was different under the 3 environmental conditions and changed gradually during exercise and recovery in all conditions. Osmolality and [Na] was highest in HD and lowest in CD. During exercise, [Na] increased with increasing SR. Although exercise duration was significantly decreased in HH (16.5 +/- 1 min) when compared to HD (28 +/- 2 min) and CD (37 +/- 2 min), fluid and ion losses in HH were comparable to those in HD as a result of a high SR and

  15. Immunohistochemical sweat gland profiles.

    Science.gov (United States)

    Noël, Fanchon; Piérard, Gérald E; Delvenne, Philippe; Quatresooz, Pascale; Humbert, Philippe; Piérard-Franchimont, Claudine

    2013-09-01

    Human sweat glands are heterogeneous in their structures and functions. Accordingly, eccrine, apocrine, and apoeccrine glands are distinguished. Some immunohistochemical markers are expected to distinguish the sweat gland types in their secretory and excretory parts. This study used two sets of antibodies. The first panel was composed of antibodies directed to well-defined sweat gland structures. The molecular targets included the low-molecular-weight cytokeratins CAM 5.2, the S100-B protein, the epithelial membrane antigen (EMA), the carcinoembryonic antigen (CEA), and the lectin Ulex europaeus agglutinin-1 (UEA-1). A second exploratory panel of antibodies targeted syndecan-1 (CD138), NKI-C3 (CD63), and CD68. They were used to disclose some undescribed antigen expressions in human sweat glands. The first set of antibodies confirmed previous findings. The immunoreactivities of the three sweat gland types were similar in the excretory ducts. By contrast, they were distinguished in the deeper coiled secretory portions of the glands. Clues supporting their distinction and probably their functional activity were obtained by immunohistochemistry using the S100-B protein, CEA and CD63 antibodies. The immunoreactivity to the S100-B protein, CEA and CD63 possibly help identifying apoeccrine sweat glands or a peculiar functional activity of eccrine sweat glands. © 2013 Wiley Periodicals, Inc.

  16. In-situ Investigation of Lead-free Solder Alloy Formation Using a Hot-plate Microscope

    DEFF Research Database (Denmark)

    Bergmann, René; Tang, Peter Torben; Hansen, Hans Nørgaard

    2007-01-01

    This work presents the advantages of using a hot-plate microscope for investigation of new (high-temperature) lead- free solders as in-situ analysis tool and preparation equipment. A description of the equipment and the preparation method is given and some examples are outlined. The formation...... of small AuSn-based, homogeneous and un-oxidized solder spheres will be demonstrated. Moreover the possibility of using this equipment as a sample preparation method to further investigation is shown. As example the equipment was used to produce samples for Vickers microhardness measurement of important...

  17. Microstructure and Mechanical Properties in Hot-Rolled Extra High-Yield-Strength Steel Plates for Offshore Structure and Shipbuilding

    Science.gov (United States)

    Liu, Dongsheng; Li, Qingliang; Emi, Toshihiko

    2011-05-01

    Key parameters for a thermomechanically controlled processing and accelerated cooling process (TMCP-AcC) were determined for integrated mass production to produce extra high-yield-strength microalloyed low carbon SiMnCrNiCu steel plates for offshore structure and bulk shipbuilding. Confocal scanning microscopy was used to make in-situ observations on the austenite grain growth during reheating. A Gleeble 3800 thermomechanical simulator was employed to investigate the flow stress behavior, static recrystallization (SRX) of austenite, and decomposition behavior of the TMCP conditioned austenite during continuous cooling. The Kocks-Mecking model was employed to describe the constitutive behavior, while the Johnson-Mehl-Avrami-Kolmogorov (JMAK) approach was used to predict the SRX kinetics. The effects of hot rolling schedule and AcC on microstructure and properties were investigated by test-scale rolling trials. The bridging between the laboratory observations and the process parameter determination to optimize the mass production was made by integrated industrial production trials on a set of a 5-m heavy plate mill equipped with an accelerated cooling system. Successful production of 60- and 50-mm-thick plates with yield strength in excess of 460 MPa and excellent toughness at low temperature (213 K (-60 °C)) in the parent metal and the simulated coarse-grained heat affected zone (CGHAZ) provides a useful integrated database for developing advanced high-strength steel plates via TMCP-AcC.

  18. Effect of DT4 Interlayer on Properties of Hot-roll Bonding TA2/Q235B Plate

    Science.gov (United States)

    Yu, Chao; Xiao, Hong; Li, Na; Qi, Zichen; Ren, Zhongkai

    2017-09-01

    In this paper, a Q235B/TA2/DT4/Q235B plate was bonded by hot-rolling in a vacuum, and the effect of including a DT4 interlayer within the TA2/Q235B plate was studied. The microstructure and properties of the composite plate at different reduction ratios were investigated by scanning electron microscopy, as well as tensile-shear, bending and tensile tests. The results show that when the reduction ratio is below 18%, the shear strength of the interface is higher with the DT4 interlayer than without it. At 35% reduction, the shear strength is similar in both cases. At a reduction ratio of 68%, with the DT4 interlayer, fracture of the bonding interface occurs on the TA2 side, whereas without the DT4 interlayer, fracture occurs on both the TA2 side and the compound layer on the interface. Including the DT4 interlayer improves the bending and tensile properties of the TA2/Q235B plate appreciably.

  19. Sweat collection capsule

    Science.gov (United States)

    Greenleaf, J. E.; Delaplaine, R. W. (Inventor)

    1980-01-01

    A sweat collection capsule permitting quantitative collection of sweat is described. The device consists of a frame held immobile on the skin, a closure secured to the frame and absorbent material located next to the skin in a cavity formed by the frame and the closure. The absorbent material may be removed from the device by removing the closure from the frame while the frame is held immobile on the skin.

  20. Processing of low carbon steel plate and hot strip—an overview

    Indian Academy of Sciences (India)

    Unknown

    before due to increasing costs of alloying elements. The control that can ... properties in steel a stark reality not visualized previously. (Siemens .... is increased. Dynamic or static recovery follows with development of sub-grains within austenite (McQueen and. Jonas 1973). Alloying elements can increase the hot strength of ...

  1. Processing of low carbon steel plate and hot strip—an overview

    Indian Academy of Sciences (India)

    Soaking temperature, drafting schedule, finish rolling and coiling temperatures all play important roles in processing of low carbon plate and strip. They control the kinetics of various physical and metallurgical processes, viz. austenitization, recrystallization and precipitation behaviour. The final transformed microstructures ...

  2. Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers

    Directory of Open Access Journals (Sweden)

    KE Amori

    2012-06-01

    Full Text Available This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

  3. Aluminium in human sweat.

    Science.gov (United States)

    Minshall, Clare; Nadal, Jodie; Exley, Christopher

    2014-01-01

    It is of burgeoning importance that the human body burden of aluminium is understood and is measured. There are surprisingly few data to describe human excretion of systemic aluminium and almost no reliable data which relate to aluminium in sweat. We have measured the aluminium content of sweat in 20 healthy volunteers following mild exercise. The concentration of aluminium ranged from 329 to 5329μg/L. These data equate to a daily excretion of between 234 and 7192μg aluminium and they strongly suggest that perspiration is the major route of excretion of systemic aluminium in humans. Copyright © 2013 Elsevier GmbH. All rights reserved.

  4. [What causes English sweats?].

    Science.gov (United States)

    Rimar, Yossi

    2004-09-01

    English sweating disease also known as Sudor Anglicus is one of the least familiar epidemics of the Middle Ages, striking England 5 times during the 15th and 16th centuries before fading. This article will discuss the knowledge available to us about this fascinating epidemic, its characteristics and causes.

  5. Hyperhidrosis (Excessive Sweating)

    Science.gov (United States)

    ... medicines also can cause this type of hyperhidrosis. Anxiety and embarrassment Both types of hyperhidrosis can cause people to feel extremely anxious and embarrassed. Students often avoid raising their hand during class. Many teens never date. Adults may hide the sweat stains ...

  6. Sweat bees on hot chillies: provision of pollination services by native bees in traditional slash-and-burn agriculture in the Yucatán Peninsula of tropical Mexico.

    Science.gov (United States)

    Landaverde-González, Patricia; Quezada-Euán, José Javier G; Theodorou, Panagiotis; Murray, Tomás E; Husemann, Martin; Ayala, Ricardo; Moo-Valle, Humberto; Vandame, Rémy; Paxton, Robert J

    2017-12-01

    Traditional tropical agriculture often entails a form of slash-and-burn land management that may adversely affect ecosystem services such as pollination, which are required for successful crop yields. The Yucatán Peninsula of Mexico has a >4000 year history of traditional slash-and-burn agriculture, termed 'milpa'. Hot 'Habanero' chilli is a major pollinator-dependent crop that nowadays is often grown in monoculture within the milpa system.We studied 37 local farmers' chilli fields (sites) to evaluate the effects of landscape composition on bee communities. At 11 of these sites, we undertook experimental pollination treatments to quantify the pollination of chilli. We further explored the relationships between landscape composition, bee communities and pollination service provision to chilli.Bee species richness, particularly species of the family Apidae, was positively related to the amount of forest cover. Species diversity decreased with increasing proportion of crop land surrounding each sampling site. Sweat bees of the genus Lasioglossum were the most abundant bee taxon in chilli fields and, in contrast to other bee species, increased in abundance with the proportion of fallow land, gardens and pastures which are an integral part of the milpa system.There was an average pollination shortfall of 21% for chilli across all sites; yet the shortfall was unrelated to the proportion of land covered by crops. Rather, chilli pollination was positively related to the abundance of Lasioglossum bees, probably an important pollinator of chilli, as well indirectly to the proportion of fallow land, gardens and pastures that promote Lasioglossum abundance. Synthesis and applications . Current, low-intensity traditional slash-and-burn ( milpa ) agriculture provides Lasioglossum spp. pollinators for successful chilli production; fallow land, gardens and pasture therefore need to be valued as important habitats for these and related ground-nesting bee species. However, the

  7. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature......’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through...

  8. Skin Effect Simulation for Area 11 Dense Plasma Focus Hot Plate

    Energy Technology Data Exchange (ETDEWEB)

    Meehan, B. Timothy [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-07-27

    Two arc flashover events occurred at the DPF Area 11 facility. These flashover events happened in the same location on the bank current delivery plates. The damage from one of these events can be seen on the left-hand side of Figure 1. Since the flashovers occurred in the same area of the bank, and the reliability of the bank is important for future DPF experiments, a failure analysis effort was initiated. Part of this failure analysis effort was an effort to understand the physical reasons behind why the flashover happened, and why it happened in the same place twice. This paper summarizes an effort to simulate the current flow in the bank in order to understand the reasons for the flashover.

  9. [Study on sweat gland regeneration induced by microenvironment of three-dimensional bioprinting].

    Science.gov (United States)

    Yao, B; Xie, J F; Huang, S; Fu, X B

    2017-01-20

    Sweat glands are abundant in the body surface and essential for thermoregulation. Sweat glands fail to conduct self-repair in patients with large area of burn and trauma, and the body temperature of patients increases in hot climate, which may cause shock or even death. Now, co-culture system, reprogramming, and tissue engineering have made progresses in inducing sweat gland regeneration, but the inductive efficiency and duration need to be improved. Cellular microenvironment can regulate cell biological behavior, including cell migration and cell differentiation. This article reviews the studies of establishment of microenvironment in vitro by three-dimensional bioprinting technology to induce sweat gland regeneration.

  10. Juan Fernández Ridge (Nazca Plate): petrology and thermochronology of a rejuvenated hot spot trail

    Science.gov (United States)

    Reyes, J.; Lara, L. E.

    2012-04-01

    The Juan Fernández Ridge on the oceanic Nazca plate is thought to be a classic hot spot trail because of the apparent westward rejuvenation of the eruptive ages. However, geochronological data is still scarce and there are a few constrains to support this hypothesis like the ca. 9 Ma Ar-Ar age of the O'Higgins seamount (115 km from the Chile-Perú trench), some published K-Ar ages of ca. 3-4 Ma in Robinson Crusoe island (580 km from the trench) and ca. 1 Ma in Alejandro Selkirk (180 km further west). New reconnaissance K-Ar ages and specially the ongoing Ar-Ar dating effort in Robinson Crusoe define a ca. 1-4 Ma time span, which partially overlap with the age of Alejandro Selkirk, breaking the expected age progression given that the Nazca plate moves eastwards at ca. 6-8 cm/yr. In addition, new geological mapping shows a sharp unconformity between the older (ca. 4 Ma), strongly altered sequences and the more recent (ca. 1 Ma), post-erosional volcanic piles, where the proximal facies are still preserved. Petrological evidence also supports this evolution pattern. In fact, the partially altered older sequence is tholeiitic (Ba/Yb=12.70; La/Yb=8.12; Ba/Y=6.51; Ba/Zr=0.89). The shield stage (ca. 1-3 Ma) is transicional from tholeiitic to alkaline (Ba/Yb=18.07-8.32; La/Yb=4.59-9.84; Ba/Y=4.24-8.18; Ba/Zr=0.73-1.09) and the younger (ca. 1 Ma) is mostly alkaline (Ba/Yb=38.15; La/Yb=15.66; Ba/Y=20.27; Ba/Zr=2.31). A fixed deep-mantle plume origin for Pacific hot spots has been widely debated and concurrent phenomena arose as a possible explanation for non-linear age progressions and/or long-lived volcanic activity. In fact, intraplate regional tectonics, plume displacement, and mantle heterogeneities could be the main factor of the ridge architecture or the mask for a first-order linear trend. An ongoing mapping and dating effort is aimed to understand the evolution of the Juan Fernández Ridge, testing the main hypothesis. This research is supported by FONDECYT Project

  11. Printing and Curing of Conductive Ink Track on Fabric using Syringe Deposition System with DLP Projector and Hot Plate

    Directory of Open Access Journals (Sweden)

    Khirotdin Rd. Khairilhijra

    2017-01-01

    Full Text Available Printing is a technique to transfer ink onto substrates to create pattern and syringe deposition system has shown some great potential in printing due to its ability to produce filamentary bead tracks which is important concerning conductivity and easily adopted on conformal surfaces which could not be realized by conventional technique. Fabrics with integrated electrical features able to create intelligent articles and may potentially open up new perspective areas of application in textile printing. However, the applicability of this technique on fabrics remains unknown which the ink used has to meet certain requirements including high electrical conductivity, resistance to oxidation, dry out without clogging, good adhesion with suitable viscosity and surface tension. Thus, there is a need to do this study which is to determine the feasibility of syringe deposition system to print a conductive ink tracks using silver epoxy-based conductive ink on fabric substrate via lycra material. This study is also aim to investigate the feasibility of using DLP projector with hot plate as another source of heat to be used in curing the ink tracks on fabric. The effect of printing and curing parameters to the characteristics and conductivity of the ink track is investigated. Several mechanical and electrical tests were also administered to determine the cure, hardness, adhesion and resistance level of the ink tracks. The results obtained were as expected which higher printing speed and lower deposition height used, a narrower and thinner ink tracks were produced. Sample with 4 mm/s of printing speed and deposition height of 1 mm resulted in dimension closer to the targeted dimension. The longer curing time and higher temperature used, a lower resistance is produced. The lowest resistance achieved is 0.9 Ω cured at 150°C for 60 minutes. The conductivity of the ink track was affected by curing process and cross-sectional area of the ink track. It is proven

  12. Wearable Sweat Rate Sensors for Human Thermal Comfort Monitoring.

    Science.gov (United States)

    Sim, Jai Kyoung; Yoon, Sunghyun; Cho, Young-Ho

    2018-01-19

    We propose watch-type sweat rate sensors capable of automatic natural ventilation by integrating miniaturized thermo-pneumatic actuators, and experimentally verify their performances and applicability. Previous sensors using natural ventilation require manual ventilation process or high-power bulky thermo-pneumatic actuators to lift sweat rate detection chambers above skin for continuous measurement. The proposed watch-type sweat rate sensors reduce operation power by minimizing expansion fluid volume to 0.4 ml through heat circuit modeling. The proposed sensors reduce operation power to 12.8% and weight to 47.6% compared to previous portable sensors, operating for 4 hours at 6 V batteries. Human experiment for thermal comfort monitoring is performed by using the proposed sensors having sensitivity of 0.039 (pF/s)/(g/m 2 h) and linearity of 97.9% in human sweat rate range. Average sweat rate difference for each thermal status measured in three subjects shows (32.06 ± 27.19) g/m 2 h in thermal statuses including 'comfortable', 'slightly warm', 'warm', and 'hot'. The proposed sensors thereby can discriminate and compare four stages of thermal status. Sweat rate measurement error of the proposed sensors is less than 10% under air velocity of 1.5 m/s corresponding to human walking speed. The proposed sensors are applicable for wearable and portable use, having potentials for daily thermal comfort monitoring applications.

  13. Ninhydrin sweat test in leprosy.

    Science.gov (United States)

    Markendeya, N; Srinivas, C R

    2004-01-01

    Loss of sensation is an important feature of leprosy. Loss of sweating over the affected site due to loss of autonomic function occurs in leprosy. We have studied a simple, non-invasive, rapid method, using 1% ninhydrin in acetone, to detect loss of sweat function. The test was effective in detecting and grading the sweat function in 84 cases of different types of leprosy. We were able to detect normal sweating in 16 patients with hypopigmented lesion due to causes other than Hansen's disease.

  14. Sweating dysfunction in Parkinson's disease

    NARCIS (Netherlands)

    Swinn, L; Schrag, A; Viswanathan, R; Lees, A; Quinn, N; Bloem, Bastiaan R.

    2003-01-01

    We sought to determine the prevalence and nature of sweating disturbances in patients with Parkinson's disease (PD), and investigated their correlation with other clinical features and with Quality of Life (QoL) measures. A questionnaire on symptoms and consequences of sweating dysfunction was

  15. Formula study for plate heat exchanger in the central heating regulation of the indirect connection hot water heating system

    National Research Council Canada - National Science Library

    Minghui CUI; Dezhi MENG; Chengming NI

    2016-01-01

    Plate heat exchanger has unique advantages and becomes dominant heat exchange equipment in heating engineering, but there is no heating regulation formula of plate exchanger applied in central heating...

  16. Comparison of fabric skins for the simulation of sweating on thermal manikins

    Science.gov (United States)

    Koelblen, Barbara; Psikuta, Agnes; Bogdan, Anna; Annaheim, Simon; Rossi, René M.

    2017-09-01

    Sweating is an important thermoregulatory process helping to dissipate heat and, thus, to prevent overheating of the human body. Simulations of human thermo-physiological responses in hot conditions or during exercising are helpful for assessing heat stress; however, realistic sweating simulation and evaporative cooling is needed. To this end, thermal manikins dressed with a tight fabric skin can be used, and the properties of this skin should help human-like sweat evaporation simulation. Four fabrics, i.e., cotton with elastane, polyester, polyamide with elastane, and a skin provided by a manikin manufacturer (Thermetrics) were compared in this study. The moisture management properties of the fabrics have been investigated in basic tests with regard to all phases of sweating relevant for simulating human thermo-physiological responses, namely, onset of sweating, fully developed sweating, and drying. The suitability of the fabrics for standard tests, such as clothing evaporative resistance measurements, was evaluated based on tests corresponding to the middle phase of sweating. Simulations with a head manikin coupled to a thermo-physiological model were performed to evaluate the overall performance of the skins. The results of the study showed that three out of four evaluated fabrics have adequate moisture management properties with regard to the simulation of sweating, which was confirmed in the coupled simulation with the head manikin. The presented tests are helpful for comparing the efficiency of different fabrics to simulate sweat-induced evaporative cooling on thermal manikins.

  17. Acute effects of dehydration on sweat composition in men during prolonged exercise in the heat.

    Science.gov (United States)

    Morgan, R M; Patterson, M J; Nimmo, M A

    2004-09-01

    To determine whether acute exercise-heat-induced dehydration affects sweat composition, eight males cycled for 2 h at 39.5 +/- 1.6% VO2peak on two separate occasions in a hot-humid environment (38.0 +/- 0.0 degrees C, 60.0 +/- 0.1% relative humidity). During exercise, subjects ingested either no fluid (dehydration) or a 20 mmol L(-1) sodium chloride solution (euhydration). The volume of solution, calculated from whole-body sweat loss and determined in a familiarization trial, was ingested at 0 min and every 15 min thereafter. Venous blood was collected at 0, 60 and 120 min of exercise and sweat was aspirated from a patch located on the dominant forearm at 120 min. Following the 2-h cycling exercise, sweat [Na+] and [Cl-] was greater (P sweat [Na+] and [Cl-] which was potentially related to greater extracellular fluid [Na+], plasma aldosterone or sympathetic nervous activity.

  18. Sweat secretion rates in growth hormone disorders

    DEFF Research Database (Denmark)

    Sneppen, S B; Main, K M; Juul, A

    2000-01-01

    While increased sweating is a prominent symptom in patients with active acromegaly, reduced sweating is gaining status as part of the growth hormone deficiency (GHD) syndrome.......While increased sweating is a prominent symptom in patients with active acromegaly, reduced sweating is gaining status as part of the growth hormone deficiency (GHD) syndrome....

  19. Why Do I Sweat So Much?

    Science.gov (United States)

    ... Your Parents - or Other Adults Why Do I Sweat So Much? KidsHealth > For Teens > Why Do I Sweat So Much? Print A A A en español ¿Por qué sudo tanto? It's perfectly normal to sweat. Sweating plays an important health role because it ...

  20. Sweat mechanisms and dysfunctions in atopic dermatitis.

    Science.gov (United States)

    Hendricks, Aleksi J; Vaughn, Alexandra R; Clark, Ashley K; Yosipovitch, Gil; Shi, Vivian Y

    2018-02-01

    Skin barrier dysfunction is inherent to atopic dermatitis (AD), causing dryness, irritation, and increased permeability to irritants, allergens and pathogens. Eccrine sweat functions as part of the skin's protective barrier. Variations in sweat responses have been observed in patients with AD, and altered sweat composition and dynamics are under-recognized as important factors in the disease cycle. This review discusses the role that sweat plays in the pathogenesis of AD, examines evidence on abnormal sweat composition, secretion, and neuro-immune responses to sweat in atopic skin, and highlights the value of sweat management. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  1. The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise-heat stress.

    Science.gov (United States)

    Hayden, Gavin; Milne, Helen C; Patterson, Mark J; Nimmo, Myra A

    2004-05-01

    Seven active male subjects cycled for 60 min at 29.5 (0.8)% peak work rate on three separate occasions in a hot environmental condition [36.0 (0.1) degrees C, 60 (1)% relative humidity] in order to determine the reproducibility of a closed-pouch sweat collection technique for sweat composition at the scapula, forearm and thigh. To confirm that sweat composition was not influenced by between-trial variations in sudomotor drive, local sweat rate, whole-body sweat rate, heart rate (HR), rectal temperature (T(re)) and mean skin temperature (T(sk)) responses were also measured, consequently reproducibility was also established for these variables. Sweat composition did not differ among trials, with the mean coefficients of variation (CVs) for sweat [Na(+)], [K(+)] and pH being 10.4 (7.4)%, 8.1 (6.5)% and 1.3 (1.1)%, respectively. Local sweat rates did not differ among the three trials (P>0.05) although whole-body sweat rate was reduced in the third trial (Psweat rates, respectively. Between-trial differences were not evident for T(re), T(sk) or HR with mean CVs of 0.3 (0.2)%, 0.7 (0.6)% and 3.9 (1.7)%, respectively, although HR tended to be greater in the first trial ( P=0.08). It is proposed that moderate variations in sweat composition were influenced by variations in the local sweat rate, which were induced by application of the pouch.

  2. The effects of oxotremorine, epibatidine, atropine, mecamylamine and naloxone in the tail-flick, hot-plate, and formalin tests in the naked mole-rat (Heterocephalus glaber)

    DEFF Research Database (Denmark)

    Dulu, Thomas D; Kanui, Titus I; Towett, Philemon K

    2014-01-01

    in antinociception by investigating the involvement of muscarinic, nicotinic and opioid receptors in nociceptive tests in this species. The effects of systemic administration of the muscarinic receptor agonist oxotremorine and the nicotinic receptor agonist epibatidine were investigated in the tail-flick, the hot......-plate, and the formalin tests. The effects of co-administration of the muscarinic receptor antagonist atropine, the nicotinic receptor antagonist mecamylamine, and the opioid receptor antagonist naloxone were also investigated. Oxotremorine and epibatidine induced a significant, dose-dependent antinociceptive effect...

  3. Hot Isostatic Press Can Optimization for Aluminum Cladding of U-10Mo Reactor Fuel Plates: FY12 Final Report and FY13 Update

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Kester D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Crapps, Justin M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Scott, Jeffrey E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Aikin, Beverly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vargas, Victor D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Duffield, Andrew N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Weinberg, Richard Y. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alexander, David J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Montalvo, Joel D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hudson, Richard W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mihaila, Bogdan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Liu, Cheng [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lovato, Manuel L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dombrowski, David E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2013-08-26

    Currently, the proposed processing path for low enriched uranium – 10 wt. pct. molybdenum alloy (LEU-10Mo) monolithic fuel plates for high power research and test reactors includes hot isostatic pressing (HIP) to bond the aluminum cladding that encapsulates the fuel foil. Initial HIP experiments were performed at Idaho National Laboratory (INL) on approximately ¼ scale “mini” fuel plate samples using a HIP can design intended for these smaller experimental trials. These experiments showed that, with the addition of a co-rolled zirconium diffusion barrier on the LEU-10Mo alloy fuel foil, the HIP bonding process is a viable method for producing monolithic fuel plates. Further experimental trials at Los Alamos National Laboratory (LANL) effectively scaled-up the “mini” can design to produce full-size fuel prototypic plates. This report summarizes current efforts at LANL to produce a HIP can design that is further optimized for higher volume production runs. The production-optimized HIP can design goals were determined by LANL and Babcock & Wilcox (B&W) to include maintaining or improving the quality of the fuel plates produced with the baseline scaled-up mini can design, while minimizing material usage, improving dimensional stability, easing assembly and disassembly, eliminating machining, and significantly reducing welding. The initial small-scale experiments described in this report show that a formed-can approach can achieve the goals described above. Future work includes scaling the formed-can approach to full-size fuel plates, and current progress toward this goal is also summarized here.

  4. Magma production rate along the Ninetyeast Ridge and its relationship to Indian plate motion and Kerguelen hot spot activity

    Digital Repository Service at National Institute of Oceanography (India)

    Sreejith, K.M.; Krishna, K.S.

    ., 1998; Krishna et al., 2001, 2009; Sager et al., 2013]. New geochronology data from core samples from the Deep Sea Drilling Project (DSDP) Sites 216, 214, 254, and Ocean Drilling Program (ODP) Sites 758, 756 along the NER suggest a linear age...; Krishna et al., 2012]. Magma production rate along the hot spot track is important for understanding the spatial and temporal behavior of mantle plumes, hot spot-spreading ridge interactions and variations in plume conduits [Mjelde et al., 2010...

  5. Determination of the maximum rate of eccrine sweat glands’ ion reabsorption using the galvanic skin conductance to local sweat rate relationship.

    Science.gov (United States)

    Amano, Tatsuro; Gerrett, Nicola; Inoue, Yoshimitsu; Nishiyasu, Takeshi; Havenith, George; Kondo, Narihiko

    2016-02-01

    The purpose of the present study was to develop and describe a simple method to evaluate the rate of ion reabsorption of eccrine sweat glands in human using the measurement of galvanic skin conductance (GSC) and local sweating rate (SR). This purpose was investigated by comparing the SR threshold for increasing GSC with following two criteria of sweat ion reabsorption in earlier studies such as (1) the SR threshold for increasing sweat ion was at approximately 0.2–0.5 mg/cm2/min and (2) exercise heat acclimation improved the sweat ion reabsorption ability and would increase the criteria 1. Seven healthy non-heat-acclimated male subjects received passive heat treatment both before and after 7 days of cycling in hot conditions (50% maximum oxygen uptake, 60 min/day, ambient temperature 32 °C, and 50% relative humidity). Subjects became partially heat-acclimated, as evidenced by the decreased end-exercise heart rate (p rate of perceived exhaustion (p maximum rate of sweat ion reabsorption of eccrine sweat glands in humans.

  6. Assessment of Uncertainties for the NIST 1016 mm Guarded-Hot-Plate Apparatus: Extended Analysis for Low-Density Fibrous-Glass Thermal Insulation.

    Science.gov (United States)

    Zarr, Robert R

    2010-01-01

    An assessment of uncertainties for the National Institute of Standards and Technology (NIST) 1016 mm Guarded-Hot-Plate apparatus is presented. The uncertainties are reported in a format consistent with current NIST policy on the expression of measurement uncertainty. The report describes a procedure for determination of component uncertainties for thermal conductivity and thermal resistance for the apparatus under operation in either the double-sided or single-sided mode of operation. An extensive example for computation of uncertainties for the single-sided mode of operation is provided for a low-density fibrous-glass blanket thermal insulation. For this material, the relative expanded uncertainty for thermal resistance increases from 1 % for a thickness of 25.4 mm to 3 % for a thickness of 228.6 mm. Although these uncertainties have been developed for a particular insulation material, the procedure and, to a lesser extent, the results are applicable to other insulation materials measured at a mean temperature close to 297 K (23.9 °C, 75 °F). The analysis identifies dominant components of uncertainty and, thus, potential areas for future improvement in the measurement process. For the NIST 1016 mm Guarded-Hot-Plate apparatus, considerable improvement, especially at higher values of thermal resistance, may be realized by developing better control strategies for guarding that include better measurement techniques for the guard gap thermopile voltage and the temperature sensors.

  7. Bioanalytical devices: Technological leap for sweat sensing

    Science.gov (United States)

    Heikenfeld, Jason

    2016-01-01

    Sweat analysis is an ideal method for continuously tracking a person's physiological state, but developing devices for this is difficult. A wearable sweat monitor that measures several biomarkers is a breakthrough. See Letter p.509

  8. Working Up a Good Sweat - The Challenges of Standardising Sweat Collection for Metabolomics Analysis.

    Science.gov (United States)

    Hussain, Joy N; Mantri, Nitin; Cohen, Marc M

    2017-02-01

    Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. A literature review of human sweat analysis over the past 10 years (2006-2016) was performed to identify studies with metabolomics or similarly applicable 'omics' analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease.

  9. Sweat Therapy Theory, Practice, and Efficacy

    Science.gov (United States)

    Eason, Allen; Colmant, Stephen; Winterowd, Carrie

    2009-01-01

    The purpose of this article is to examine the potential application of sweat rituals to group counseling, adventure therapy, and other forms of group work by describing a theoretical model for how sweat rituals work and presenting the results of a randomized comparative outcome study on the efficacy of sweat therapy. The theoretical model proposes…

  10. Emergence of silicic continents as the lower crust peels off on a hot plate-tectonic Earth

    Science.gov (United States)

    Chowdhury, Priyadarshi; Gerya, Taras; Chakraborty, Sumit

    2017-09-01

    The rock record and geochemical evidence indicate that continental recycling has been occurring since the early history of the Earth. The stabilization of felsic continents in place of Earth's early mafic crust about 3.0 to 2.0 billion years ago, perhaps due to the initiation of plate tectonics, implies widespread destruction of mafic crust during this time interval. However, the physical mechanisms of such intense recycling on a hotter, (late) Archaean and presumably plate-tectonic Earth remain largely unknown. Here we use thermomechanical modelling to show that extensive recycling via lower crustal peeling-off (delamination but not eclogitic dripping) during continent-continent convergence was near ubiquitous during the late Archaean to early Proterozoic. We propose that such destruction of the early mafic crust, together with felsic magmatism, may have caused both the emergence of silicic continents and their subsequent isostatic rise, possibly above the sea level. Such changes in the continental character have been proposed to influence the Great Oxidation Event and, therefore, peeling-off plate tectonics could be the geodynamic trigger for this event. A transition to the slab break-off controlled syn-orogenic recycling occurred as the Earth aged and cooled, leading to reduced recycling and enhanced preservation of the continental crust of present-day composition.

  11. Do elephants need to sweat?

    African Journals Online (AJOL)

    higher increase (Clifford, Kerslake & Waddell 1959). Thus a number of factors studied under laboratory condi- tions in non-sweating human skin are pertinenl to this con- sideration of evaporative waler loss froro elephant skin and we have shown that the evaporative loss could provide the heat transfer necessary for thermal ...

  12. Validation of the DIFFAL, HPAC and HotSpot Dispersion Models Using the Full-Scale Radiological Dispersal Device (FSRDD) Field Trials Witness Plate Deposition Dataset.

    Science.gov (United States)

    Purves, Murray; Parkes, David

    2016-05-01

    Three atmospheric dispersion models--DIFFAL, HPAC, and HotSpot--of differing complexities have been validated against the witness plate deposition dataset taken during the Full-Scale Radiological Dispersal Device (FSRDD) Field Trials. The small-scale nature of these trials in comparison to many other historical radiological dispersion trials provides a unique opportunity to evaluate the near-field performance of the models considered. This paper performs validation of these models using two graphical methods of comparison: deposition contour plots and hotline profile graphs. All of the models tested are assessed to perform well, especially considering that previous model developments and validations have been focused on larger-scale scenarios. Of the models, HPAC generally produced the most accurate results, especially at locations within ∼100 m of GZ. Features present within the observed data, such as hot spots, were not well modeled by any of the codes considered. Additionally, it was found that an increase in the complexity of the meteorological data input to the models did not necessarily lead to an improvement in model accuracy; this is potentially due to the small-scale nature of the trials.

  13. Sweat as an Efficient Natural Moisturizer.

    Science.gov (United States)

    Shiohara, Tetsuo; Sato, Yohei; Komatsu, Yurie; Ushigome, Yukiko; Mizukawa, Yoshiko

    2016-01-01

    Although recent research on the pathogenesis of allergic skin diseases such as atopic dermatitis has focused on defects in skin genes important for maintaining skin barrier function, the fact that excreted sweat has an overwhelmingly great capacity to increase skin surface hydration and contains moisturizing factors has long been ignored: the increase in water loss induced by these gene defects could theoretically be compensated fully by a significant increase in sweating. In this review, the dogma postulating the detrimental role of sweat in these diseases has been challenged on the basis of recent findings on the physiological functions of sweat, newly recognized sweat gland-/duct-related skin diseases, and therapeutic approaches to the management of these diseases. We are now beginning to appreciate that sweat glands/ducts are a sophisticated regulatory system. Furthermore, depending on their anatomical location and the degree of the impairment, this system might have a different function: sweating responses in sweat glands/ducts located at the folds in hairy skin such as on the trunk and extremities could function as natural regulators that maintain skin hydration under quiescent basal conditions, in addition to the better-studied thermoregulatory functions, which can be mainly mediated by those at the ridges. The normal functioning of sweat could be disturbed in various inflammatory skin diseases. Thus, we should recognize sweating disturbance as an etiologic factor in the development of these diseases. © 2016 S. Karger AG, Basel.

  14. Urea transporters and sweat response to uremia.

    Science.gov (United States)

    Keller, Raymond W; Bailey, James L; Wang, Yanhua; Klein, Janet D; Sands, Jeff M

    2016-06-01

    In humans, urea is excreted in sweat, largely through the eccrine sweat gland. The urea concentration in human sweat is elevated when compared to blood urea nitrogen. The sweat urea nitrogen (UN) of patients with end-stage kidney disease (ESRD) is increased when compared with healthy humans. The ability to produce sweat is maintained in the overwhelming majority of ESRD patients. A comprehensive literature review found no reports of sweat UN neither in healthy rodents nor in rodent models of chronic kidney disease (CKD). Therefore, this study measured sweat UN concentrations in healthy and uremic rats. Uninephrectomy followed by renal artery ligation was used to remove 5/6 of renal function. Rats were then fed a high-protein diet to induce uremia. Pilocarpine was used to induce sweating. Sweat droplets were collected under oil. Sweat UN was measured with a urease assay. Serum UN was measured using a fluorescent ortho-pthalaldehyde reaction. Immunohistochemistry (IHC) was accomplished with a horseradish peroxidase and diaminobenzidine technique. Sweat UN in uremic rats was elevated greater than two times compared to healthy pair-fed controls (220 ± 17 and 91 ± 15 mmol/L, respectively). Post hoc analysis showed a significant difference between male and female uremic sweat UN (279 ± 38 and 177 ± 11 mmol/L, respectively.) IHC shows, for the first time, the presence of the urea transporters UT-B and UT-A2 in both healthy and uremic rat cutaneous structures. Future studies will use this model to elucidate how rat sweat UN and other solute excretion is altered by commonly prescribed diuretics. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  15. Thermal influence on palmar sweating and mental influence on generalized sweating in man.

    Science.gov (United States)

    Ogawa, T

    1975-01-01

    Sweat rates on the forearm and on the palm were simultaneously recorded by resistance hygrometry and the mode of sweating in these areas in response to thermal and non-thermal stimuli were compared with each other. In Series A, periodic infrared irradiation (1 min on, 1 min off) was done to the back of the trunk, and reflex responses in sweat rate were recorded on both test areas. A high correlation was noted between the mean changes in the palmar sweat rate and those in the forearm one during the irradiation cycle in a majority of cases. However the magnitude of the sweat response was much less on the palm than on the forearm. These observations reveal that the central mechanism of palmar sweating may be affected to some extent by the thermoregulatory mechanism. Series B was concerned with the pattern of response in forearm sweating to various non-thermal stimuli. Careful observations showed that the forearm sweating responded diversely to various mental stimuli, unlike the palmar sweating whose response was always an increase. Mental arithmetic, mental testing and physical exercise caused an immediate increase in the palmar sweating but often elicited a transient decrease in the forearm sweating, whereas pain, noise, and emotional stimuli consistently provoked an increase of sweating on the forearm as well as on the palm. These observations suggest that the activities of higher centers, presumably involving neocortex and limbic cortex, exert various influences on the central mechanisms of palmar and generalized sweating.

  16. The Laser Welding with Hot Wire of 316LN Thick Plate Applied on ITER Correction Coil Case

    CERN Document Server

    Fang, Chao; Wu, Weiyue; Wei, Jing; Zhang, Shuquan; Li, Hongwei; Dolgetta, N; Libeyre, P; Cormany, C; Sgobba, S

    2014-01-01

    ITER correction coil (CC) cases have characteristics of small cross section, large dimensions, and complex structure. The cases are made of heavy thick (20 mm), high strength and high toughness austenitic stainless steel 316LN. The multi-pass laser welding with hot wire technology is used for the case closure welding, due to its low heat input and deformation. In order to evaluate the reliability of this welding technology, 20 mm welding samples with the same groove structure and welding depth as the cases were welded. High purity argon was used as the shielding gas to prevent oxidation because of the narrowness and depth of the weld. In this paper investigation of, microstructure characteristics and mechanical properties of welded joints using optimized welding parameters are presented. The results show that the base metal, fusion metal, and heat affected zone (HAZ) are all have fully austenitic microstructure, and that the grain size of fusion metal was finer than that of the base metal. The welding resulte...

  17. Carbon dioxide cooling systems in Denmark. Supermarkets, plate freezers, transport cooling, hot water heat pumps; CO2-koelinstallaties in Denemarken. Supermarkten, platenvriezers, transportkoeling, heetwaterwarmtepompen

    Energy Technology Data Exchange (ETDEWEB)

    Kauffeld, M.; Bertelsen, P.; Hansen, T.M.; Christensen, K.G. [Dansk Teknologisk Institut, Aarhus (Denmark)

    2002-08-01

    To avoid future problems with new synthetic refrigerants, natural refrigerants are preferable. The choice should be guided by a Life Cycle Analysis, to make sure that the environmental impact of energy consumption does not exceed that of synthetic refrigerants. For commercial refrigeration, the combination of propane in a central plant with a secondary refrigerant for chill conditions and a cascade with CO2 for freeze conditions offers efficient solutions. Plate freezers are served best by CO2 in cascade with NH3, or in singular application, especially for fishing vessels in cold seas. For Container Reefer Units, the transcritical compression cycle equals the conventional R134a cycle. Hydrocarbons present solutions for road transport. The CO2 compression cycle promises better energy efficiency of hot water heat pumps at large temperature differences. Demonstration objects were realised in cooperation with related industries. 3 Supermarket plants with propane and secondary circuit are operational, two of which were built in cooperation with DTI, the first since May 2000, without failures. First operational experiences are gathered from a CO2 plate freezer. A new defrosting method was registered for patent. The CO2 container reefer unit exists as operational prototype, equally efficient as R134a units. Presently a CO2 hot water heat pump is being built for testing early 2002. [Dutch] Ter voorkoming van toekomstige problemen met steeds nieuwe synthetische koudemiddelen verdienen natuurlijke koudemiddelen de voorkeur. Aan de keuze van een natuurlijk koudemiddelen moet echter een Life Cycle Analyse voorafgaan, om veilig te stellen dat de totale emissie van broeikasgassen door energiegebruik die van synthetische koudemiddelen niet overstijgt. Voor commerciele koeling ligt de keuze van een centrale R290 (propaan) installatie voor de hand, met een koudedrager voor koelcondities en CO2 in cascade voor vriescondities. Platenvriezers met NH3 en CO2 in cascade tonen

  18. Sweat sensor for sports physiological monitoring

    OpenAIRE

    Benito-Lopez, Fernando; Coyle, Shirley; Diamond, Dermot

    2011-01-01

    The fabrication and the performance of a novel, wearable, robust, flexible and disposable micro-fluidic device which incorporates miniature optical components as a detection system, for wireless monitoring in real time mode of sweat pH during an exercise session is presented. This micro-fluidic platform is completely non-invasive, providing a continuous flow of fresh sweat for continuous real time analysis, ensuring immediate feedback regarding sweat composition to an athlete and/or coach.

  19. Distinguishing hyperhidrosis and normal physiological sweat production

    DEFF Research Database (Denmark)

    Thorlacius, Linnea; Gyldenløve, Mette; Zachariae, Claus

    2015-01-01

    of this study was to establish reference intervals for normal physiological axillary and palmar sweat production. METHODS: Gravimetric testing was performed in 75 healthy control subjects. Subsequently, these results were compared with findings in a cohort of patients with hyperhidrosis and with the results...... 100 mg/5 min. CONCLUSIONS: A sweat production rate of 100 mg/5 min as measured by gravimetric testing may be a reasonable cut-off value for distinguishing axillary and palmar hyperhidrosis from normal physiological sweat production....

  20. Working Up a Good Sweat – The Challenges of Standardising Sweat Collection for Metabolomics Analysis

    Science.gov (United States)

    Hussain, Joy N; Mantri, Nitin; Cohen, Marc M

    2017-01-01

    Introduction Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. Methods A literature review of human sweat analysis over the past 10 years (2006–2016) was performed to identify studies with metabolomics or similarly applicable ‘omics’ analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. Results Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. Conclusion Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease. PMID:28798503

  1. Sweating the small stuff: adequacy and accuracy in sweat chloride determination.

    Science.gov (United States)

    DeMarco, Mari L; Dietzen, Dennis J; Brown, Sarah M

    2015-04-01

    Sweat chloride testing is the gold standard for diagnosis of cystic fibrosis (CF). Our objectives were to: 1) describe variables that determine sweat rate; 2) determine the analytic and diagnostic capacity of sweat chloride analysis across the range of observed sweat rates; and 3) determine the biologic variability of sweat chloride concentration. A retrospective analysis was performed using data from all sweat chloride tests performed at St. Louis Children's Hospital over a 21-month period. A total of 1397 sweat chloride tests (1155 sufficient [≥75 mg], 242 insufficient [sweat weight collected from forearms was statistically greater than that collected from legs. There was a negligible correlation between sweat weight and chloride concentration (r=-0.06). The mean individual biologic CV calculated from individuals with two or more sweat collections ≥75 mg was 13.1% (95% CI: 11.3-14.9%; range 0-88%) yielding a reference change value of 36%. Using 60 mmol/L as the diagnostic chloride cutoff, 100% of CF cases were detected whether a minimum sweat weight of 75, 40, or 20 mg was required. 1) Collection of sweat from forearms is preferable to upper legs, particularly in very young infants; 2) sweat chloride concentrations are not highly dependent upon sweat rate; 3) a change in sweat chloride concentration exceeding 36% may be considered a clinically significant response to cystic fibrosis transmembrane receptor targeted therapy, and 4) sweat collections of less than 75 mg provide clinically accurate information. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Cation transport by sweat ducts in primary culture. Ionic mechanism of cholinergically evoked current oscillations

    DEFF Research Database (Denmark)

    Larsen, Erik Hviid; Novak, I; Pedersen, P S

    1990-01-01

    1. The coiled reabsorptive segment of human sweat ducts was cultured in vitro. Cells were then harvested and plated onto a dialysis membrane which was glued over a hole in a small disc. Cultures were maintained in a low serum, hormone-supplemented medium that allowed the cells to grow to confluency...

  3. Does Replacing Sodium Excreted in Sweat Attenuate the Health Benefits of Physical Activity?

    Science.gov (United States)

    Turner, Martin J; Avolio, Alberto P

    2016-08-01

    International guidelines suggest limiting sodium intake to 86-100 mmol/day, but average intake exceeds 150 mmol/day. Participants in physical activities are, however, advised to increase sodium intake before, during and after exercise to ensure euhydration, replace sodium lost in sweat, speed rehydration and maintain performance. A similar range of health benefits is attributable to exercise and to reduction in sodium intake, including reductions in blood pressure (BP) and the increase of BP with age, reduced risk of stroke and other cardiovascular diseases, and reduced risk of osteoporosis and dementia. Sweat typically contains 40-60 mmol/L of sodium, leading to approximately 20-90 mmol of sodium lost in one exercise session with sweat rates of 0.5-1.5 L/h. Reductions in sodium intake of 20-90 mmol/day have been associated with substantial health benefits. Homeostatic systems reduce sweat sodium as low as 3-10 mmol/L to prevent excessive sodium loss. "Salty sweaters" may be individuals with high sodium intake who perpetuate their "salty sweat" condition by continual replacement of sodium excreted in sweat. Studies of prolonged high intensity exercise in hot environments suggest that sodium supplementation is not necessary to prevent hyponatremia during exercise lasting up to 6 hr. We examine the novel hypothesis that sodium excreted in sweat during physical activity offsets a significant fraction of excess dietary sodium, and hence may contribute part of the health benefits of exercise. Replacing sodium lost in sweat during exercise may improve physical performance, but may attenuate the long-term health benefits of exercise.

  4. Sweat function in the diabetic foot

    Directory of Open Access Journals (Sweden)

    Markendeya Nirmala

    2004-01-01

    Full Text Available Background: Autonomic dysfunction, an early manifestation of diabetic neuropathy, presents with altered sweating patterns, leading to dryness and fissuring. We conducted a study to assess the sweat function in the diabetic foot and to determine the interrelation between the duration of diabetes, sensation, fissuring, and sweating. Methods: The sweat function was assessed in 30 diabetic patients, 28 of whom had fissuring of the feet, using Ninhydrin impregnated discs. Results: There was a significant association between fissuring and sensation, but not between the duration of diabetes and fissuring and between loss of sweating and fissuring. In 18 patients (60% there was impairment or absence of sweating in the presence of normal sensation. Conclusion: Although fissuring increases with long-standing diabetes and sweating is reduced in diabetic patients with fissures on the foot, the correlation between these entities was not statistically significant. Since 60% patients had altered sweating in the presence of normal sensations, the sweat test can be used as an early indicator of diabetic neuropathy.

  5. Hot Plate Annealing at a Low Temperature of a Thin Ferroelectric P(VDF-TrFE Film with an Improved Crystalline Structure for Sensors and Actuators

    Directory of Open Access Journals (Sweden)

    Rahman Ismael Mahdi

    2014-10-01

    Full Text Available Ferroelectric poly(vinylidene fluoride-trifluoroethylene (P(VDF-TrFE copolymer 70/30 thin films are prepared by spin coating. The crystalline structure of these films is investigated by varying the annealing temperature from the ferroelectric phase to the paraelectric phase. A hot plate was used to produce a direct and an efficient annealing effect on the thin film. The dielectric, ferroelectric and pyroelectric properties of the P(VDF-TrFE thin films are measured as a function of different annealing temperatures (80 to 140 °C. It was found that an annealing temperature of 100 °C (slightly above the Curie temperature, Tc has induced a highly crystalline β phase with a rod-like crystal structure, as examined by X-ray. Such a crystal structure yields a high remanent polarization, Pr = 94 mC/m2, and pyroelectric constant, p = 24 μC/m2K. A higher annealing temperature exhibits an elongated needle-like crystal domain, resulting in a decrease in the crystalline structure and the functional electrical properties. This study revealed that highly crystalline P(VDF-TrFE thin films could be induced at 100 °C by annealing the thin film with a simple and cheap method.

  6. Precise measurement of instantaneous volume of eccrine sweat gland in mental sweating by optical coherence tomography

    Science.gov (United States)

    Sugawa, Yoshihiko; Fukuda, Akihiro; Ohmi, Masato

    2015-03-01

    We have demonstrated dynamic analysis of the physiological function of eccrine sweat glands underneath skin surface by optical coherence tomography (OCT). We propose a method for extraction of the target eccrine sweat gland by use of the connected component extraction process and the adaptive threshold method, where the en-face OCT images are constructed by the SS-OCT. Furthermore, we demonstrate precise measurement of instantaneous volume of the sweat gland in response to the external stimulus. The dynamic change of instantaneous volume of eccrine sweat gland in mental sweating is performed by this method during the period of 300 sec with the frame intervals of 3.23 sec.

  7. Sweat rate and sweat electrolyte composition in international female soccer players during game specific training.

    Science.gov (United States)

    Kilding, A E; Tunstall, H; Wraith, E; Good, M; Gammon, C; Smith, C

    2009-06-01

    The purpose of this study was to determine the sweat rate and sweat electrolyte composition in female international level soccer players. Thirteen soccer players performed two 90 min soccer-specific training sessions (T1 and T2) on separate days. Hydration status was determined prior to each session and sweat loss, sweat rate and sweat composition (Na (+), K (+), Mg (++) and Ca (+)) were determined from patches worn during training. The mean sweat rate during T1 and T2 was 0.50+/-0.20 and 0.43+/-0.18 L.h (-1) respectively (P>0.05). The mean sweat electrolyte composition during T1 and T2 was: [Na (+)]: 43.9+/-15.0 and 46.2+/-7.9 mmol.L (-1); [K (+)]: 6.1+/-1.1 and 5.2+/-1.1 mmol.L (-1); [Mg (++)]: 0.1+/-0.0 and 0.1+/-0.0 mmol.L (-1); [Ca (+)]: 1.2+/-0.5 and 0.7+/-0.1 mmol.L (-1), respectively. When data from T1 and T2 were combined, there were no relationships between sweat rate and sweat concentration of any electrolyte. In conclusion, the sweat rate and sweat electrolyte losses in this cohort of international female soccer players, during soccer-specific training in cool conditions, were small. Electrolyte losses of this magnitude are unlikely to require special consideration in terms of optimising player hydration.

  8. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study

    OpenAIRE

    Kaneko, Sakae; Murota, Hiroyuki; Murata, Susumu; Katayama, Ichiro; Morita, Eishin

    2017-01-01

    Background. Sweat is an aggravating factor in atopic dermatitis (AD), regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy’s involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years) to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine rele...

  9. Development of ion-plated aluminide diffusion coatings for thermal cyclic oxidation and hot corrosion protection of a nickel-based superalloy and a stainless steel

    Science.gov (United States)

    Elsawy, Abdel Raouf

    This project was carried out at the University of Toronto and Cametoid Ltd of Whitby, Ontario. Ohno continuous casting; a novel net shape casting technique, was used to generate, Al-Y, Al-Ce, Al-La, and Al-Si-Y, in form of 1.6 to 1.7 mm diameter alloy wires. These alloy wires exhibited suitable properties for use as feed materials to an Ion Vapor Deposition facility. The deposition parameters were optimized to provide coatings with a compact and cohesive columnar structure with reduced porosity and diffusion barriers that were essential to ensure the success of the diffusion process in the subsequent stage. Solid-state diffusion heat treatment processes were developed in order to form the stable aluminide phases, AlNi and FeAl, on IN738 and S310 substrates, respectively. Experiments simulating the coating service conditions and environments encountered during the prospective aerospace and fuel cell applications were conducted to evaluate the performance of each aluminide coating developed during this study. Thermal cyclic oxidation and molten sulfate corrosion studies were performed on coated IN738 pins at 1050°C and 900°C, respectively, simulating the service environment of turbine engine blades and other hot section components. Molten carbonate corrosion behavior was investigated for coated S310 coupons that were immersed in, or covered with a thin film of molten carbonate, at 650°C, in air plus 30%CO2, to simulate the operating conditions of the cathode-side separator plates of molten carbonate fuel cells. The behavior of the reactive elements, yttrium, cerium, lanthanum, and silicon in enhancing the adhesion of the protective aluminum oxide scale was determined by weight variation experiments, structural examination and compositional analysis. The influence of the base material elements, nickel, chromium, and iron, on the formation of protective oxides was investigated. All coatings were found to provide significant improvement for thermal cyclic oxidation

  10. Sex differences in amino acids lost via sweating could lead to differential susceptibilities to disturbances in nitrogen balance and collagen turnover.

    Science.gov (United States)

    Dunstan, R H; Sparkes, D L; Dascombe, B J; Stevens, C J; Murphy, G R; Macdonald, M M; Gottfries, J; Gottfries, C-G; Roberts, T K

    2017-08-01

    Fluid collected during sweating is enriched with amino acids derived from the skin's natural moisturising factors and has been termed "faux" sweat. Little is known about sex differences in sweat amino acid composition or whether faux sweat amino acid losses affect nitrogen balance. Faux sweat collected by healthy adults (n = 47) after exercise, and at rest by chronic fatigue patients, was analysed for amino acid composition. Healthy females had higher total amino acid concentrations in sweat (10.5 ± 1.2 mM) compared with healthy males (6.9 ± 0.9 mM). Females had higher levels of 13 amino acids in sweat including serine, alanine and glycine. Higher hydroxyproline and proline levels suggested greater collagen turnover in females. Modelling indicated that with conservative levels of exercise, amino acid losses in females via faux sweat were triple than those predicted for urine, whereas in males they were double. It was concluded that females were more susceptible to key amino acid loss during exercise and/or hot conditions. Females reporting chronic fatigue had higher levels of methionine in faux sweat than healthy females. Males reporting chronic fatigue had higher levels of numerous amino acids in faux sweat compared to healthy males. Higher amino acid loss in faux sweat associated with chronic fatigue could contribute to a hypometabolic state. Depending on activity levels, climatic conditions and gender, amino acid losses in sweat and skin leachate could influence daily protein turnover where periods of continuously high turnover could lead to a negative net nitrogen balance.

  11. Experimental analysis of solar thermal integrated MD system for cogeneration of drinking water and hot water for single family villa in dubai using flat plate and evacuated tube solar collectors

    DEFF Research Database (Denmark)

    Asim, Muhammad; Imran, Muhammad; Leung, Michael K.H.

    2017-01-01

    This paper presents the experimental analysis performed on solar thermal integrated membrane distillation (MD) system using flat plate and evacuated tube collectors. The system will be utilized for cogeneration of drinking water and domestic hot water for single family in Dubai comprising of four...... on MD setup at optimized flow rates of 6 L/min on hot side and 3 L/min on cold side for producing the desired distillate. The hot side and cold side MD temperature has been maintained between 60°C and 70°C, and 20°C and 30°C. The total annual energy demand comes out to be 8,223 kWh (6,000 k...

  12. Collaborative guarded-hot-plate tests between the Laboratoire national de métrologie et d’essais and the National Institute of Standards and Technology

    Science.gov (United States)

    Zarr, Robert R.; Guthrie, William F.; Hay, Bruno; Koenen, Alain

    2017-02-01

    A collaborative study to compare the long-term measurement performance between guarded-hot-plate facilities at the Laboratoire national de métrologie et d’essais (LNE) in France and the National Institute of Standards and Technology (NIST) in the United States is presented. Thermal conductivity data were compiled from three international comparisons organized from 1997 to 2014. Measurements were conducted in accordance with standardized test methods (ISO 8302 or ASTM C 177) over a temperature range from 280 K to 320 K. Nine thermal insulating materials (either mineral fiber or expanded polystyrene) were examined covering broad ranges of bulk densities (13 kg · m-3-200 kg · m-3) and thicknesses (13 mm-70 mm). A different set of specimens was utilized for each comparison. Results of this study indicate that, over a 17 year interval, the majority of test data from LNE and NIST agreed to within  ±1.0%, or less, for mineral fiber materials and to within  ±0.5%, or less, for expanded polystyrene. The long-term variability limit of 1% between the two laboratories is in good agreement with their current measurement uncertainties. Regression coefficients and their standard uncertainties for a straight-line model relating thermal conductivity to temperature from 280 K to 320 K were computed by material and laboratory. Graphical analysis of the data and corresponding fits exhibit consistent behavior by material type between the two laboratories. Sources of measurement variability are addressed.

  13. Variability of measurements of sweat sodium using the regional absorbent-patch method.

    Science.gov (United States)

    Dziedzic, Christine E; Ross, Megan L; Slater, Gary J; Burke, Louise M

    2014-09-01

    There is interest in including recommendations for the replacement of the sodium lost in sweat in individualized hydration plans for athletes. Although the regional absorbent-patch method provides a practical approach to measuring sweat sodium losses in field conditions, there is a need to understand the variability of estimates associated with this technique. Sweat samples were collected from the forearms, chest, scapula, and thigh of 12 cyclists during 2 standardized cycling time trials in the heat and 2 in temperate conditions. Single measure analysis of sodium concentration was conducted immediately by ion-selective electrodes (ISE). A subset of 30 samples was frozen for reanalysis of sodium concentration using ISE, flame photometry (FP), and conductivity (SC). Sweat samples collected in hot conditions produced higher sweat sodium concentrations than those from the temperate environment (P = .0032). A significant difference (P = .0048) in estimates of sweat sodium concentration was evident when calculated from the forearm average (mean ± 95% CL; 64 ± 12 mmol/L) compared with using a 4-site equation (70 ± 12 mmol/L). There was a high correlation between the values produced using different analytical techniques (r2 = .95), but mean values were different between treatments (frozen FP, frozen SC > immediate ISE > frozen ISE; P sweat sodium concentration estimates differed depending on the number of sites included in the calculation. Environmental testing conditions should be considered in the interpretation of results. The impact of sample freezing and subsequent analytical technique was small but statistically significant. Nevertheless, when undertaken using a standardized protocol, the regional absorbent-patch method appears to be a relatively robust field test.

  14. Precise measurement of volume of eccrine sweat gland in mental sweating by optical coherence tomography

    Science.gov (United States)

    Sugawa, Yoshihiko; Fukuda, Akihiro; Ohmi, Masato

    2015-04-01

    We have demonstrated dynamic analysis of the physiological function of eccrine sweat glands underneath skin surface by optical coherence tomography (OCT). In this paper, we propose a method for extraction of the specific eccrine sweat gland by means of the connected component extraction process and the adaptive threshold method, where the en face OCT images are constructed by the swept-source OCT. In the experiment, we demonstrate precise measurement of the volume of the sweat gland in response to the external stimulus.

  15. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study.

    Science.gov (United States)

    Kaneko, Sakae; Murota, Hiroyuki; Murata, Susumu; Katayama, Ichiro; Morita, Eishin

    2017-01-01

    Background . Sweat is an aggravating factor in atopic dermatitis (AD), regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy's involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years) to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine release tests (HRT). Furthermore, 24 of the patients received instructions on methods of sweat management, and their outcomes were evaluated on a 10-point scale. Results. Sweat HRT results were class ≥ 2 in 13 patients, but HRT results were not correlated with the patients' self-assessments of symptom aggravation by sweat. One month after receiving sweat management instructions, a low mean score of 4.6 was obtained regarding whether active sweating was good, but a high mean score of 7.0 was obtained in response to whether the sweat management instructions had been helpful. Conclusion . Our investigation showed that patients' negative impressions of sweat might derive from crude personal experiences that are typically linked to sweating. Sweat management for patients with adult atopic dermatitis was extremely useful regardless of sweat allergy.

  16. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Sakae Kaneko

    2017-01-01

    Full Text Available Background. Sweat is an aggravating factor in atopic dermatitis (AD, regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy’s involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine release tests (HRT. Furthermore, 24 of the patients received instructions on methods of sweat management, and their outcomes were evaluated on a 10-point scale. Results. Sweat HRT results were class ≥ 2 in 13 patients, but HRT results were not correlated with the patients’ self-assessments of symptom aggravation by sweat. One month after receiving sweat management instructions, a low mean score of 4.6 was obtained regarding whether active sweating was good, but a high mean score of 7.0 was obtained in response to whether the sweat management instructions had been helpful. Conclusion. Our investigation showed that patients’ negative impressions of sweat might derive from crude personal experiences that are typically linked to sweating. Sweat management for patients with adult atopic dermatitis was extremely useful regardless of sweat allergy.

  17. Recent Developments in Sweat Analysis and Its Applications

    Directory of Open Access Journals (Sweden)

    Saima Jadoon

    2015-01-01

    Full Text Available Currently, the clinical use of sweat as biofluid is limited. The collection of sweat and its analysis for determining ethanol, drugs, ions, and metals have been encompassed in this review article to assess the merits of sweat compared to other biofluids, for example, blood or urine. Moreover, sweat comprises various biomarkers of different diseases including cystic fibrosis and diabetes. Additionally, the normalization of sampled volume of sweat is also necessary for getting efficient and useful results.

  18. Evolution: plastic sociality in a sweat bee.

    Science.gov (United States)

    Chapuisat, Michel

    2010-11-23

    How and why do bees become social? A transplant experiment shows that sweat bees can adopt a solitary or social lifestyle in response to their environment. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. 7 CFR 29.3554 - Sweating.

    Science.gov (United States)

    2010-01-01

    ... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  20. 7 CFR 29.3553 - Sweated.

    Science.gov (United States)

    2010-01-01

    ... INSPECTION Standards Official Standard Grades for Dark Air-Cured Tobacco (u.s. Types 35, 36, 37 and Foreign Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  1. Effects of short-term exercise in the heat on thermoregulation, blood parameters, sweat secretion and sweat composition of tropic-dwelling subjects.

    Science.gov (United States)

    Saat, Mohamed; Sirisinghe, Roland Gamini; Singh, Rabindarjeet; Tochihara, Yutaka

    2005-09-01

    This study investigates the effects of a short-term aerobic training program in a hot environment on thermoregulation, blood parameters, sweat secretion and composition in tropic-dwellers who have been exposed to passive heat. Sixteen healthy Malaysian-Malay male volunteers underwent heat acclimation (HA) by exercising on a bicycle ergometer at 60% of VO2max for 60 min each day in a hot environment (Ta: 31.1+/-0.1 degrees C, rh: 70.0+/-4.4%) for 14 days. All parameters mentioned above were recorded on Day 1 and at the end of HA (Day 16). On these two days, subjects rested for 10 min, then cycled at 60% of VO2max for 60 min and rested again for 20 min (recovery) in an improvised heat chamber. Rectal temperature (Tre), mean skin temperature (Tsk) heart rate (HR), ratings of perceived exertion (RPE), thermal sensation (TS), local sweat rate and percent dehydration were recorded during the test. Sweat concentration was analysed for sodium [Na+]sweat and potassium. Blood samples were analysed for biochemical changes, electrolytes and hematologic indices. Urine samples were collected before and after each test and analysed for electrolytes.After the period of acclimation the percent dehydration during exercise significantly increased from 1.77+/-0.09% (Day 1) to 2.14+/-0.07% (Day 16). Resting levels of hemoglobin, hematocrit and red blood cells decreased significantly while [Na+]sweat increased significantly. For Tre and Tsk there were no differences at rest. Tre, HR, RPE, TS, plasma lactate concentration, hemoglobin and hematocrit at the 40th min of exercise were significantly lower after the period of acclimation but mean corpuscular hemoglobin and serum osmolality were significantly higher while no difference was seen in [Na+]sweat and Tsk. It can be concluded that tropic-dwelling subjects, although exposed to prolonged passive heat exposure, were not fully heat acclimatized. To achieve further HA, they should gradually expose themselves to exercise-heat stress in a

  2. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability

    OpenAIRE

    Baker, Lindsay B.

    2017-01-01

    Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for a...

  3. A new method of sweat testing: the CF Quantum®sweat test.

    Science.gov (United States)

    Rock, Michael J; Makholm, Linda; Eickhoff, Jens

    2014-09-01

    Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland-Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97-0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94-100%) and 96% (95% confidence interval: 89-99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%) (p sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  4. Tropical Malaysians and temperate Koreans exhibit significant differences in sweating sensitivity in response to iontophoretically administered acetylcholine

    Science.gov (United States)

    Lee, Jeong-Beom; Bae, Jun-Sang; Matsumoto, Takaaki; Yang, Hun-Mo; Min, Young-Ki

    2009-03-01

    Natives of the tropics are able to tolerate high ambient temperatures. This results from their long-term residence in hot and often humid tropical climates. This study was designed to compare the peripheral mechanisms of thermal sweating in tropical natives with that of their temperate counterparts. Fifty-five healthy male subjects including 20 native Koreans who live in the temperate Korean climate (Temperate-N) and 35 native tropical Malaysian men that have lived all of their lives in Malaysia (Tropical-N) were enrolled in this study after providing written informed consent to participate. Quantitative sudomotor axon reflex testing after iontophoresis (2 mA for 5 min) with 10% acetylcholine (ACh) was used to determine directly activated (DIR) and axon reflex-mediated (AXR) sweating during ACh iontophoresis. The sweat rate, activated sweat gland density, sweat gland output per single gland activated, and oral and skin temperature changes were measured. The sweat onset time of AXR (nicotinic-receptor-mediated) was 56 s shorter in the Temperate-N than in the Tropical-N subjects ( P stress.

  5. Sweating the small stuff: Glycoproteins in human sweat and their unexplored potential for microbial adhesion.

    Science.gov (United States)

    Peterson, Robyn A; Gueniche, Audrey; Adam de Beaumais, Ségolène; Breton, Lionel; Dalko-Csiba, Maria; Packer, Nicolle H

    2016-03-01

    There is increasing evidence that secretory fluids such as tears, saliva and milk play an important role in protecting the human body from infection via a washing mechanism involving glycan-mediated adhesion of potential pathogens to secretory glycoproteins. Interaction of sweat with bacteria is well established as the cause of sweat-associated malodor. However, the role of sweat glycoproteins in microbial attachment has received little, if any, research interest in the past. In this review, we demonstrate how recent published studies involving high-throughput proteomic analysis have inadvertently, and fortuitously, exposed an abundance of glycoproteins in sweat, many of which have also been identified in other secretory fluids. We bring together research demonstrating microbial adhesion to these secretory glycoproteins in tears, saliva and milk and suggest a similar role of the sweat glycoproteins in mediating microbial attachment to sweat and/or skin. The contribution of glycan-mediated microbial adhesion to sweat glycoproteins, and the associated impact on sweat derived malodor and pathogenic skin infections are unchartered new research areas that we are beginning to explore. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Hydration, sweat and thermoregulatory responses to professional football training in the heat.

    Science.gov (United States)

    Duffield, Rob; McCall, Allan; Coutts, Aaron James; Peiffer, Jeremiah John

    2012-01-01

    AbstThis study examined the relationship between intensity of training and changes in hydration status, core temperature, sweat rate and composition and fluid balance in professional football players training in the heat. Thirteen professional football players completed three training sessions; "higher-intensity" (140 min; HI140), "lower-intensity" (120 min; LI120) and "game-simulation" (100 min; GS100). Movement demands were measured by Global Positioning System, sweat rate and concentration were determined from dermal patches and body mass change. Despite similar environmental conditions (26.9 ± 0.1 °C and 65.0 ± 7.0% relative humidity [Rh]), higher relative speeds (m · min(-1)) and increased perceptions of effort and thermal strain were observed in HI140 and GS100 compared with LI120 (P sweat rate (L · h(-1)) and electrolyte losses (g) were observed in HI140 and GS100 compared with LI120. Rate of rise in core temperature was correlated with mean speed (r = 0.85), session rating of perceived exertion (sRPE) (r = 0.61), loss of potassium (K+) (r = 0.51) sweat rate (r = 0.49), and total sweat loss (r = 0.53), with mean speed the strongest predictor. Sodium (Na+) (r = 0.39) and K+ (r = 0.50) losses were associated with total distance covered. In hot conditions, individualised rehydration practices should be adopted following football training to account for differences in sweat rate and electrolyte losses in response to intensity and overall activity within a session.

  7. Whole body sweat collection in humans: an improved method with preliminary data on electrolyte content.

    Science.gov (United States)

    Shirreffs, S M; Maughan, R J

    1997-01-01

    Previous methods used to collect human sweat for electrolyte analysis have been criticized because they involve only regional sampling or because of methodological problems associated with whole body-washdown techniques. An improved method for collection of whole body sweat from exercising subjects is described. It involved construction of a plastic frame that supports a large plastic bag within which the subject exercises. The subject and the equipment are washed with distilled, deionized water before exercise begins. After exercise is completed, the subject and equipment are again washed with water containing a marker not present in sweat (ammonium sulfate). Total sweat loss is calculated from the change in body mass, and the volume of sweat not evaporated is calculated from dilution of the added marker. Recovery of added water was 102 +/- 2% (SD) of the added volume, and recovery of added electrolytes was 99 +/- 2% for sodium, 98 +/- 9% for potassium, and 101 +/- 4% for chloride. Repeated trials (n = 4) on five subjects to establish the reproducibility of the method gave a coefficient of variation of 17 +/- 5% for sodium, 23 +/- 6% for potassium, and 15 +/- 6% for chloride. These values include the biological variability between trials as well as the error within the method. The biological variability thus appears to be far greater than the methodological error. Normal values for the composition of sweat induced by exercise in a hot, humid environment in healthy young men and women were (in mM) 50.8 +/- 16.5 sodium, 4.8 +/- 1.6 potassium, 1.3 +/- 0.9 calcium, 0.5 +/- 0.5 magnesium, and 46.6 +/- 13.1 chloride.

  8. Hot flushes | van Schoor | South African Family Practice

    African Journals Online (AJOL)

    Vasomotor symptoms, such as hot flushes and night sweats, are considered to be the cardinal symptoms of menopause, and are experienced by most women. The physiology of hot flushes is not fully understood, and is likely to reflect the interplay between multiple central and peripheral physiological systems. Reproductive ...

  9. Real-time sweat analysis via alternating current conductivity of artificial and human sweat

    Science.gov (United States)

    Liu, Gengchen; Alomari, Mahmoud; Sahin, Bunyamin; Snelgrove, Samuel E.; Edwards, Jeffrey; Mellinger, Axel; Kaya, Tolga

    2015-03-01

    Dehydration is one of the most profound physiological challenges that significantly affects athletes and soldiers if not detected early. Recently, a few groups have focused on dehydration detection using sweat as the main biomarker. Although there are some proposed devices, the electrical and chemical characteristics of sweat have yet to be incorporated into the validations. In this work, we have developed a simple test setup to analyze artificial sweat that is comprised the main components of human sweat. We provide theoretical and experimental details on the electrical and chemical behavior of the artificial sweat for various concentration values within a temperature range of 5 °C to 50 °C. We have also developed an efficient sweat collecting and detection system based on 3D printing. Human studies were conducted and this particular protocol has shown that dehydration starts to take effect as early as 40 min into the physical activity if there is no fluid intake during the exercise. We believe that our device will lead to developing viable real-time sweat analysis systems.

  10. Biological variability of the sweat chloride in diagnostic sweat tests: A retrospective analysis.

    Science.gov (United States)

    Vermeulen, F; Lebecque, P; De Boeck, K; Leal, T

    2017-01-01

    The sweat test is the current gold standard for the diagnosis of cystic fibrosis (CF). CF is unlikely when sweat chloride (Cl sw ) is lower than 30mmol/L, Cl sw >60 is suggestive of CF, with intermediate values between 30 and 60mmol/L. To correctly interpret a sweat chloride value, the biological variability of the sweat chloride has to be known. Sweat tests performed in two centers using the classic Gibson and Cooke method were retrospectively reviewed (n=5904). Within test variability of Cl sw was measured by comparing results from right and left arm collected on the same day. Between test variability was calculated from subjects with sweat tests performed on more than one occasion. Within test variability of Cl sw calculated in 1022 subjects was low with differences between -3.2 (p5) and +3.6mmol/L (p95). Results from left and right arm were classified differently in only 3 subjects. Between test variability of Cl sw in 197 subjects was larger, with differences between -18.2mmol/L (p5) and +14.1mmol/L (p95) between repeat tests. Changes in diagnostic conclusion were seen in 55/197 subjects, the most frequent being changing from indeterminate to 'CF unlikely' range (48/102). Variability of sweat chloride is substantial, with frequent changes in diagnostic conclusion, especially in the intermediate range. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  11. Hydrochromic Approaches to Mapping Human Sweat Pores.

    Science.gov (United States)

    Park, Dong-Hoon; Park, Bum Jun; Kim, Jong-Man

    2016-06-21

    Hydrochromic materials, which undergo changes in their light absorption and/or emission properties in response to water, have been extensively investigated as humidity sensors. Recent advances in the design of these materials have led to novel applications, including monitoring the water content of organic solvents, water-jet-based rewritable printing on paper, and hydrochromic mapping of human sweat pores. Our interest in this area has focused on the design of hydrochromic materials for human sweat pore mapping. We recognized that materials appropriate for this purpose must have balanced sensitivities to water. Specifically, while they should not undergo light absorption and/or emission transitions under ambient moisture conditions, the materials must have sufficiently high hydrochromic sensitivities that they display responses to water secreted from human sweat pores. In this Account, we describe investigations that we have carried out to develop hydrochromic substances that are suitable for human sweat pore mapping. Polydiacetylenes (PDAs) have been extensively investigated as sensor matrices because of their stimulus-responsive color change property. We found that incorporation of headgroups composed of hygroscopic ions such as cesium or rubidium and carboxylate counterions enables PDAs to undergo a blue-to-red colorimetric transition as well as a fluorescence turn-on response to water. Very intriguingly, the small quantities of water secreted from human sweat pores were found to be sufficient to trigger fluorescence turn-on responses of the hydrochromic PDAs, allowing precise mapping of human sweat pores. Since the hygroscopic ion-containing PDAs developed in the initial stage display a colorimetric transition under ambient conditions that exist during humid summer periods, a new system was designed. A PDA containing an imidazolium ion was found to be stable under all ambient conditions and showed temperature-dependent hydrochromism corresponding to a

  12. Excretion of Δ9-Tetrahydrocannabinol in Sweat

    Science.gov (United States)

    Huestis, Marilyn A.; Scheidweiler, Karl B.; Saito, Takeshi; Fortner, Neil; Abraham, Tsadik; Gustafson, Richard A.; Smith, Michael L.

    2008-01-01

    Sweat testing is a noninvasive technique for monitoring drug exposure over a 7-day period in treatment, criminal justice, and employment settings. We evaluated Δ9-tetrahydrocannabinol (THC) excretion in 11 daily cannabis users after cessation of drug use. PharmChek® sweat patches worn for 7 days were analyzed for THC by gas chromatography-mass spectrometry (GC/MS). The limit of quantification (LOQ) for the method was 0.4 ng THC/patch. Sweat patches worn the first week of continuously monitored abstinence had THC above the United States Substance Abuse Mental Health Services Administration’s proposed cutoff concentration for federal workplace testing of 1 ng THC/patch. Mean ± S.E.M. THC concentrations were 3.85 ± 0.86 ng THC/patch. Eight of 11 subjects had negative patches the second week and one produced THC positive patches for four weeks of monitored abstinence. We also tested daily and weekly sweat patches from 7 subjects who were administered oral doses of up to 14.8 mg THC/day for five consecutive days. In this oral THC administration study, no daily or weekly patches had THC above the LOQ; concurrent plasma THC concentrations were all less than 6.1 μg/L. In conclusion, using proposed federal cutoff concentrations, most daily cannabis users will have a positive sweat patch in the first week after ceasing drug use and a negative patch after subsequent weeks, although patches may remain positive for four weeks or more. Oral ingestion of up to 14.8 mg THC daily does not produce a THC positive sweat patch test. PMID:17481836

  13. Surface contamination artificially elevates initial sweat mineral concentrations

    Science.gov (United States)

    During exercise in the heat, sweat is initially concentrated in minerals, but serial sweat samples appear more dilute. Possible causes include reduced dermal mineral concentrations or flushing of surface contamination. PURPOSE: To simultaneously sample mineral concentrations in transdermal fluid (T...

  14. Cannabis Use Surveillance by Sweat Analysis.

    Science.gov (United States)

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  15. 'My sweat my health': Real time sweat analysis using wearable micro-fluidic devices

    OpenAIRE

    Curto, Vincenzo F.; Angelov, Nikolay; Coyle, Shirley; Byrne, Robert; Hughes, Sarah; Moyna, Niall; Diamond, Dermot; Benito-Lopez, Fernando

    2011-01-01

    In this work a robust, non-invasive and wearable micro-fluidic system was developed and employed to analyse pH of sweat in real time during exercise. The device is incorporated in an optical detection platform designed to provide real-time information on sweat composition. The device has been tested by monitoring the pH of sweat during 55 minutes of cycling activity. During these trials, the data obtained by the micro-fluidic system was compared to pH measurements obtained in parallel studies...

  16. Prediction of Water Requirements to Replace Sweat Losses

    Science.gov (United States)

    2010-10-01

    RTO-MP-HFM-202 P6 - 1 Prediction of Water Requirements to Replace Sweat Losses Samuel N. Cheuvront, Ph.D., Richard R. Gonzalez, Ph.D...3. DATES COVERED - 4. TITLE AND SUBTITLE Prediction of Water Requirements to Replace Sweat Losses 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...Prediction of Water Requirements to Replace Sweat Losses P6 - 2 RTO-MP-HFM-202 Conclusion OSEC and PW provide for more accurate sweat

  17. A portable optical human sweat sensor

    Science.gov (United States)

    Al-omari, Mahmoud; Liu, Gengchen; Mueller, Anja; Mock, Adam; Ghosh, Ruby N.; Smith, Kyle; Kaya, Tolga

    2014-11-01

    We describe the use of HNQ (2-hydroxy-1,4-naphthoquinone or Lawsone) as a potential sweat sensor material to detect the hydration levels of human beings. We have conducted optical measurements using both artificial and human sweat to validate our approach. We have determined that the dominant compound that affects HNQ absorbance in artificial sweat is sodium. The presence of lactate decreases the reactivity of HNQ while urea promotes more interactions of sodium and potassium ions with HNQ. The interactions between the hydroxyl group of HNQ and the artificial sweat components (salts, lactic acid, and urea) were investigated comprehensively. We have also proposed and developed a portable diode laser absorption sensor system that converts the absorbance at a particular wavelength range (at 455 ± 5 nm, where HNQ has an absorbance peak) into light intensity measurements via a photocell. The absorbance intensity values obtained from our portable sensor system agrees within 10.4% with measurements from a laboratory based ultraviolet-visible spectrometer. Findings of this research will provide significant information for researchers who are focusing on real-time, in-situ hydration level detection.

  18. OUT Success Stories: Solar Hot Water Technology

    Energy Technology Data Exchange (ETDEWEB)

    Clyne, R.

    2000-08-31

    Solar hot water technology was made great strides in the past two decades. Every home, commercial building, and industrial facility requires hot water. DOE has helped to develop reliable and durable solar hot water systems. For industrial applications, the growth potential lies in large-scale systems, using flat-plate and trough-type collectors. Flat-plate collectors are commonly used in residential hot water systems and can be integrated into the architectural design of the building.

  19. OUT Success Stories: Solar Hot Water Technology

    Science.gov (United States)

    Clyne, R.

    2000-08-01

    Solar hot water technology was made great strides in the past two decades. Every home, commercial building, and industrial facility requires hot water. DOE has helped to develop reliable and durable solar hot water systems. For industrial applications, the growth potential lies in large-scale systems, using flat-plate and trough-type collectors. Flat-plate collectors are commonly used in residential hot water systems and can be integrated into the architectural design of the building.

  20. Comparison of sweat loss estimates for women during prolonged high-intensity running.

    Science.gov (United States)

    Cheuvront, Samuel N; Haymes, Emily M; Sawka, Michael N

    2002-08-01

    This study evaluated the error produced by four commonly used field estimates and two prediction equations of total body sweat loss. Eight women distance runners were studied during a 30-km treadmill run (approximately 70% .VO(2max)) in a warm (30 degrees C T(db)) and a cool (14 degrees C T(db)) environment. Total sweat loss (TSL) was determined from changes in body mass corrected for fluid intake (FI), urine losses (UL), clothing (trapped sweat, TS), CO(2)-O(2) exchange (metabolic mass loss, MML), and respiratory water loss (RWL). TSL was compared with four estimates of sweat losses (often employed in the field) from body mass changes corrected for: a) FI only (F-1); b) FI and TS (F-2); c) FI and UL (F-3); or d) FI, TS, and UL (F-4). Two prediction equations were used also for comparison to TSL values. In the warm environment, F-1, F-3, and F-4 accurately estimated (0.2-6.9%; P > 0.05) TSL, whereas F-2 produced a large error (15.3%; P equations markedly underestimated (20-22%) TSL in the warm environment and underestimated (41%) or overestimated (20%) TSL in the cool environment. TSL can be accurately estimated from changes in body mass using F-1, F-3, or F-4 methods in hot environments; however, none of the methods accurately estimated actual TSL values in a cool environment. Neither prediction equation provided accurate estimates of TSL in warm or cool conditions for women runners. These results illustrate the difficulty of accurately estimating and predicting sweat losses in the field.

  1. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

    Science.gov (United States)

    Baker, Lindsay B

    2017-03-01

    Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes' SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.

  2. Variations in regional sweat composition in normal human males.

    Science.gov (United States)

    Patterson, M J; Galloway, S D; Nimmo, M A

    2000-11-01

    This project aimed to quantify the regional distribution of sweat composition over the skin surface and to determine whether sweat constituent concentrations collected from regional sites can estimate whole-body concentrations. Ten males cycled for 90 min in a 20 degrees C (50% relative humidity) environment at 45% peak aerobic power. Sweat was collected from eleven skin regions and the whole body, using a wash-down technique. Strong relationships were evident between the regional and whole-body sweat [Na+] and [Cl-], such that the thigh and calf exhibited greater correlation coefficients than area-weighted means derived from four and eight skin regions. Therefore, in this particular protocol the whole-body sweat [Na+] and [Cl-] could be predicted from regional sweat collections. Relationships between sweat constituents were evident for sweat [Na+] and pH, and sweat [K+] and [lactate] when data were pooled between skin regions and subjects. To our knowledge this is the first investigation to report a positive relationship between sweat [K+] and [lactate]. The exact mechanism responsible for the positive relationship between sweat [K+] and [lactate] is uncertain although it is speculated to occur at the secretory coil.

  3. Skin Tattoos Alter Sweat Rate and Na+ Concentration.

    Science.gov (United States)

    Luetkemeier, Maurie Joe; Hanisko, Joseph Michael; Aho, Kyle Mathiew

    2017-07-01

    The popularity of tattoos has increased tremendously in the last 10 yr particularly among athletes and military personnel. The tattooing process involves permanently depositing ink under the skin at a similar depth as eccrine sweat glands (3-5 mm). The purpose of this study was to compare the sweat rate and sweat Na concentration of tattooed versus nontattooed skin. The participants were 10 healthy men (age = 21 ± 1 yr), all with a unilateral tattoo covering a circular area at least 5.2 cm. Sweat was stimulated by iontophoresis using agar gel disks impregnated with 0.5% pilocarpine nitrate. The nontattooed skin was located contralateral to the position of the tattooed skin. The disks used to collect sweat were composed of Tygon® tubing wound into a spiral so that the sweat was pulled into the tubing by capillary action. The sweat rate was determined by weighing the disk before and after sweat collection. The sweat Na concentration was determined by flame photometry. The mean sweat rate from tattooed skin was significantly less than nontattooed skin (0.18 ± 0.15 vs 0.35 ± 0.25 mg·cm·min; P = 0.001). All 10 participants generated less sweat from tattooed skin than nontattooed skin and the effect size was -0.79. The mean sweat Na concentration from tattooed skin was significantly higher than nontattooed skin (69.1 ± 28.9 vs 42.6 ± 15.2 mmol·L; P = 0.02). Nine of 10 participants had higher sweat Na concentration from tattooed skin than nontattooed skin, and the effect size was 1.01. Tattooed skin generated less sweat and a higher Na concentration than nontattooed skin when stimulated by pilocarpine iontophoresis.

  4. Study on unified fatigue strength assessment method for welded structure. Hot spot stress evaluating method for various combinations of plate thickness and weld leg length; Yosetsu kozo no toitsutekina hiro kyodo hyokaho ni kansuru kenkyu. Itaatsu to yosetsu ashinaga no kumiawase ni taisuru hot spot oryoku sanshutsu ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Nihei, K.; Inamura, F.; Koe, S. [Kawasaki Heavy Industries, Ltd., Kobe (Japan)

    1996-12-31

    There has been tried to apply unified assessment method using hot spot stress, which is effective to evaluate fatigue strength of fillet welded structures for ships and marine structures. This method can be applied to complicated structures and is independent of welding processes. In this study, first, stress analysis has been conducted for two-dimensional fillet welded joint models with various combinations of plate thickness and weld leg length of general fillet structures by means of boundary element method. Then, critical position, which is not affected by local stress concentration due to bead, was determined from the detailed stress distribution in the vicinity of weld toe. As a result, a general equation has been proposed to estimate the hot spot stress by one-point representative method. Second, the fatigue tests of typical fillet welded joints have been conducted by applying this method. Consequently, it was demonstrated that the unified fatigue strength can be evaluated by the S-N data based on hot spot stress range determined from the proposed equation, independent of structural stress concentration. 22 refs., 14 figs.

  5. Interindividual variability in sweat electrolyte concentration in marathoners.

    Science.gov (United States)

    Lara, Beatriz; Gallo-Salazar, César; Puente, Carlos; Areces, Francisco; Salinero, Juan José; Del Coso, Juan

    2016-01-01

    Sodium (Na(+)) intake during exercise aims to replace the Na(+) lost by sweat to avoid electrolyte imbalances, especially in endurance disciplines. However, Na(+) needs can be very different among individuals because of the great inter-individual variability in sweat electrolyte concentration. The aim of this investigation was to determine sweat electrolyte concentration in a large group of marathoners. A total of 157 experienced runners (141 men and 16 women) completed a marathon race (24.4 ± 3.6 °C and 27.7 ± 4.8 % of humidity). During the race, sweat samples were collected by using sweat patches placed on the runners' forearms. Sweat electrolyte concentration was measured by using photoelectric flame photometry. As a group, sweat Na(+) concentration was 42.9 ± 18.7 mmol·L(-1) (minimal-maximal value = 7.0-95.5 mmol·L(-1)), sweat Cl(-) concentration was 32.2 ± 15.6 mmol·L(-1) (7.3-90.6 mmol·L(-1)) and sweat K(+) concentration was 6.0 ± 0.9 mmol·L(-1) (3.1-8.0 mmol·L(-1)). Women presented lower sweat Na(+) (33.9 ± 12.1 vs 44.0 ± 19.1 mmol·L(-1); P = 0.04) and sweat Cl(-) concentrations (22.9 ± 10.5 vs 33.2 ± 15.8 mmol·L(-1); P = 0.01) than men. A 20 % of individuals presented a sweat Na(+) concentration higher than 60 mmol·L(-1) while this threshold was not surpassed by any female marathoner. Sweat electrolyte concentration did not correlate to sweat rate, age, body characteristics, experience or training. Although there was a significant correlation between sweat Na(+) concentration and running pace (r = 0.18; P = 0.03), this association was weak to interpret that sweat Na(+) concentration increased with running pace. The inter-individual variability in sweat electrolyte concentration was not explained by any individual characteristics except for individual running pace and sex. An important portion (20 %) of marathoners might need special sodium intake recommendations due to

  6. Vitamin B12 deficiency causing night sweats.

    Science.gov (United States)

    Rehman, H U

    2014-11-01

    Vitamin B12 deficiency is common. It is known to cause a wide spectrum of neurological syndromes, including autonomic dysfunction. Three cases are discussed here in which drenching night sweats were thought to be caused by vitamin B12 deficiency. All three responded dramatically to vitamin B12 therapy. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Testing in artificial sweat - Is less more? Comparison of metal release in two different artificial sweat solutions.

    Science.gov (United States)

    Midander, Klara; Julander, Anneli; Kettelarij, Jolinde; Lidén, Carola

    2016-11-01

    Metal release from materials immersed in artificial sweat can function as a measure of potential skin exposure. Several artificial sweat models exist that, to various degree, mimic realistic conditions. Study objective was to evaluate metal release from previously examined and well characterized materials in two different artificial sweat solutions; a comprehensive sweat model intended for use within research, based on the composition of human sweat; and the artificial sweat, EN1811, intended for testing compliance with the nickel restriction in REACH. The aim was to better understand whether there are advantages using either of the sweat solutions in bio-elution testing of materials. Metal release in two different artificial sweat solutions was compared for discs of a white gold alloy and two hard metals, and a rock drilling insert of tungsten carbide at 1 h, 24 h, 1 week and 1 month. The released amount of metal was analysed by means of inductively coupled plasma mass spectrometry. Similar levels of released metals were measured from test materials in the two different artificial sweat solutions. For purposes in relation to legislations, it was concluded that a metal release test using a simple artificial sweat composition may provide results that sufficiently indicate the degree of metal release at skin contact. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Quantification of sweat gland volume and innervation in neuropathy: Correlation with thermoregulatory sweat testing.

    Science.gov (United States)

    Loavenbruck, Adam; Wendelschaefer-Crabbe, Gwen; Sandroni, Paola; Kennedy, William R

    2014-10-01

    No study has correlated thermoregulatory sweat testing (TST) with histopathologic study of sweat glands (SGs) and SG nerve fibers (SGNFs). We studied 10 neuropathy patients in whom anhidrosis was found by TST and 10 matched controls. Skin biopsies were taken from both anhidrotic and sweating skin and immunohistochemical staining was done for nerves and basement membrane. For each biopsy, total tissue volume, total SG volume, and total SGNF length were measured. SGNF length per biopsy volume, SG volume per biopsy volume (SG%), and SGNF length per SG volume were calculated. SGNF length per biopsy volume was reduced in anhidrotic site biopsies of patients compared with controls. SG% was decreased and SGNF length per SG volume increased in patients compared with controls. The results suggest a concomitant loss of SG volume and SGNF length in neuropathy, with greater loss of SGNFs in anhidrotic skin, possibly exceeding collateral reinnervation. Copyright © 2014 Wiley Periodicals, Inc.

  9. Quality of sweat test (ST) based on the proportion of sweat sodium (Na) and sweat chloride (Cl) as diagnostic parameter of cystic fibrosis: are we on the right way?

    Science.gov (United States)

    Faria, Alethéa Guimarães; Marson, Fernando Augusto Lima; Gomez, Carla Cristina de Souza; Ribeiro, Maria Ângela Gonçalves de Oliveira; Morais, Lucas Brioschi; Servidoni, Maria de Fátima; Bertuzzo, Carmen Sílvia; Sakano, Eulália; Goto, Maura; Paschoal, Ilma Aparecida; Pereira, Mônica Corso; Hessel, Gabriel; Levy, Carlos Emílio; Toro, Adyléia Aparecida Dalbo Contrera; Peixoto, Andressa Oliveira; Simões, Maria Cristina Ribeiro; Lomazi, Elizete Aparecida; Nogueira, Roberto José Negrão; Ribeiro, Antônio Fernando; Ribeiro, José Dirceu

    2016-10-26

    To assess the quality of sweat test (ST) based on the proportion of sweat sodium and sweat chloride as diagnostic parameter of cystic fibrosis (CF). A retrospective study of 5,721 sweat samples and subsequent descriptive analysis were carried out. The test was considered "of good quality" (correct) when: (i) sweat chloride was lower than 60 mEq/L, and sweat sodium was higher than sweat chloride; (ii) sweat chloride was higher than 60 mEq/L, and sweat sodium was lower than sweat chloride. The study included 5,692/5,721 sweat samples of ST which had been requested due to clinical presentations compatible with CF and/or neonatal screenings with altered immunoreactive trypsinogen values. Considering the proportion of sweat sodium and sweat chloride as ST quality parameter, the test was performed correctly in 5,023/5,692 (88.2 %) sweat samples. The sweat chloride test results were grouped into four reference ranges for chloride (i) chloride sweat weight (p = 0.416). However, there was a positive association with: (i) gender, (ii) results of ST (p sweat chloride/sodium ratio (p sweat chloride values (p = 0.047), (iii) subject's age at the time of the ST grouped by numerical order (p = 0.001). Considering that the quality of ST can be assessed by levels of sweat sodium and sweat chloride, an increasing number of low-quality tests could be observed in our sweat samples. The quality of the test was associated with important factors, such as gender, CF diagnosis, and subjects' age.

  10. Influence of digoxin and diuretic therapy on sweat fluid composition.

    Science.gov (United States)

    Mor, A; Benzon, L; Aladjem, M

    1985-01-01

    The effect of digitalis and diuretic therapy on sweat fluid composition was investigated. Patients treated for congestive heart failure with a combination of digoxin and diuretics demonstrated a higher concentration of sodium and chloride in their sweat fluid when compared to age-matched controls. The administration of diuretics alone did not affect sweat fluid composition. The digoxin-induced increase in sodium concentration was significantly higher than that observed for chloride. These data suggest that digoxin markedly inhibits sodium reabsorption along the sweat gland tubule, whereas chloride transport is affected to a lesser degree. A significant correlation between sweat fluid sodium and serum digoxin concentrations was observed. We conclude that the increased digoxin-induced sweat sodium and chloride losses may affect sodium homeostasis in patients with congestive heart failure.

  11. Voluntary drinking versus imposed drinking in the methodology of investigations about the drinking-induced thermoregulatory sweating.

    Science.gov (United States)

    Hosseinlou, Abdollah; Khamnei, Saeed; Zamanlu, Masumeh

    2014-01-01

    Studies have shown that dehydrated humans or animals in a warm environment begin to sweat within seconds to minutes after drinking. This phenomenon is one of the drinking-induced thermoregulatory responses; being investigated from different aspects. Our objective is to show the difference of voluntary drinking and imposed drinking in the methodology of these experiments. Six healthy subjects 23.7 ± 0.6 yr old and 80.7 ± 5.7 kg wt were dehydrated by performing mild exercise (ergometer cycling) in a hot and humid chamber (38-40°C, 20-28% relative humidity). We incorporated two protocols: after dehydration, subjects were allowed to drink water with 1) imposed volumes of 1, 3, 5 ml/kg and 2) voluntary volumes; on four separate days. The sweating rate was measured on the forehead area before and after drinking. Sweating increased markedly just a few minutes after the onset of drinking. The mean sweat rates of the imposed volumes of 1, 3, 5 ml/Kg were 0.33 ± 0.15, 0.31 ± 0.17, 0.47 ± 0.21 respectively and for the voluntary volume it was 0.54 ± 0.19. The mean intake in the voluntary trial was 6.58 ± 1.14 ml/Kg, more than the imposed volume of 5 ml/Kg. The trend of the rate of the sweating response in the imposed trials was distinct from the response in the voluntary trial. There exists a difference between voluntary drinking and imposed drinking in the sweating response that follows rehydration. So it is suggested to use the methods of voluntary drinking in the investigations of this phenomenon, to reveal the natural events that happen in the actual circumstances.

  12. Sweat conductivity: an accurate diagnostic test for cystic fibrosis?

    Science.gov (United States)

    Mattar, Ana Claudia Veras; Leone, Claudio; Rodrigues, Joaquim Carlos; Adde, Fabíola Villac

    2014-09-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. Sweat conductivity is widely used although still considered a screening test. This was a prospective, cross-sectional, diagnostic research conducted at the laboratory of the Instituto da Criança of the Hospital das Clínicas, São Paulo, Brazil. Sweat chloride (quantitative pilocarpine iontophoresis) and sweat conductivity tests were simultaneously performed in patients referred for a sweat test between March 2007 and October 2008. Conductivity and chloride cut-off values used to rule out or diagnose CF were sweat chloride and conductivity values were 11 and 25 mmol/L in these populations, respectively. Twenty-four patients who had received a diagnosis of CF presented median sweat chloride and conductivity values of 87 and 103 mmol/L, respectively. Conductivity values above 90 mmol/L had 83.3% sensitivity, 99.7% specificity, 90.9% PPV and 99.4% NPV to diagnose CF. The best conductivity cut-off value to exclude CF was sweat conductivity test yielded a high degree of diagnostic accuracy and it showed good agreement with sweat chloride. We suggest that it should play a role as a diagnostic test for CF in the near future. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  13. Decreased sweating in seven patients with Laron syndrome

    DEFF Research Database (Denmark)

    Main, K M; Price, D A; Savage, M O

    1993-01-01

    Previous studies have shown that sweat secretion was reduced in patients with GH deficiency and increased during GH treatment, indicating an influence of GH on sweat gland function. Thus, patients with GH deficiency have impaired thermoregulation. We report on sweat secretion rates (SSRs) in seven......). These observations further supported the hypothesis that sweat gland function in humans is under the influence of the GH-insulin-like growth factor-I axis. It remains to be seen whether the decrease in SSR also leads to altered thermoregulation in patients with Laron syndrome....

  14. [Amounts of sweat and salt loss due to sweating during a three-hour badminton practice in summer].

    Science.gov (United States)

    Hashimoto, Yoshiaki; Watanabe, Nobuko; Futamura, Azusa

    2007-11-01

    In 7 men and 5 women, we measured the amounts of sweat and fluid intake, and the ionic composition of sweat during a 3-hour badminton practice in summer. The amount of sweat was calculated as follows; body weight before practice (g)--body weight after practice (g)--urine volume (ml) +fluid intake (ml). We collected sweat by covering the non-dominant forearm with a plastic bag. The amounts of sweat and fluid intake during the 3-hour practice were 1809 +/- 715ml (mean +/- SD) and 658 +/- 344ml, respectively. Weight loss after the practice was 2.0 +/- 0.9% of their weight before the practice. The Na(+) and Cl(-) levels of the sweat about 30 min after the start of practice were 66 +/- 34 mEq/l and 54 +/- 32mEq/l, respectively. There was no significant difference between those ionic levels of the sweat about 30 min after the start of practice and those about 30 min before the end of practice. The sum of Na(+) and Cl(-) loss into sweat during a 3-hour practice session was supposed to be 6.9 +/- 5.3g, and to be above 10 g in 4 of 7 men, assuming that there were no regional differences in the ionic composition of sweat. The findings suggested that most of the participants should take more fluid and some of them might need salt intake during the practice.

  15. Effect of plasma prolactin on sweat rate and sweat composition during exercise in men.

    Science.gov (United States)

    Boisvert, P; Brisson, G R; Péronnet, F

    1993-05-01

    We investigated the role of the exercise-induced elevation of plasma prolactin (PRL) concentration on sweat rate and composition during prolonged exercise in men. Two groups of healthy young males (20-26 yr old) showing a high (high responders; n = 8) or a low (low responders; n = 7) response of plasma PRL concentration to exercise were studied during a 60-min period of exercise on a cycle ergometer (65% maximum O2 consumption) in warm conditions (26.2 +/- 0.1 degrees C; 57 +/- 1% relative humidity), 1 h after receiving 1.25 mg bromocriptine (BRC) per os or a placebo. In high responders, administration of BRC totally abolished the threefold increase in plasma PRL observed in response to exercise with placebo [placebo, 10 +/- 2 (rest) and 30 +/- 2 micrograms/l (exercise); BRC, 9 +/- 1 (rest) and 8 +/- 1 microgram/l (exercise)]. The latter was associated with a significant decrease in sweat rate (2.7 +/- 0.5 to 1.9 +/- 0.3 microliter.cm-2.min-1) and a significant increase in sweat Na+ concentration (57 +/- 7 to 68 +/- 5 mmol/l). BRC also reduced the small response in plasma PRL concentration observed in low responders [placebo, 10 +/- 1 (rest) and 15 +/- 1 microgram/l (exercise); BRC, 9 +/- 1 (rest) and 7 +/- 1 microgram/l (exercise)], but this was not associated with any change in sweat rate (2.2 +/- 0.2 to 1.9 +/- 0.3 microliter.cm-2.min-1) or in sweat Na+ concentration (63 +/- 10 to 64 +/- 9 mmol/l).(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Characteristics of sweating responses and peripheral sweat gland function during passive heating in sprinters.

    Science.gov (United States)

    Amano, Tatsuro; Koga, Shunsaku; Inoue, Yoshimitsu; Nishiyasu, Takeshi; Kondo, Narihiko

    2013-08-01

    The purpose of this study was to compare sweating function in sprinters who have trained for several years with untrained subjects and trained endurance runners. Two separate experiments were conducted. Nine sprinters, eight untrained men, and nine distance runners (VO2 max 50.9 ± 1.4, 38.2 ± 1.8, and 59.1 ± 1.2 mL/kg/min, respectively; P sprinters, 11 untrained men and nine distance runners (similar VO2 max levels compared with Experiment 1 in each group) had their sweat gland capacity assessed based on acetylcholine-induced sweating rate (SR) (Experiment 2). The slope of the mean non-glabrous SR plotted against change in mean body temperature during passive heating did not differ significantly between sprinters and untrained men (1.21 ± 0.10 and 0.97 ± 0.12 mg cm(-2)/min/°C, respectively); in contrast, compared with untrained men, distance runners exhibited a significantly greater slope (1.42 ± 0.11 mg cm(-2)/min/°C, P sprinters and untrained men, whereas distance runners showed a significantly higher induced SR compared with untrained men. The sweating function was not improved in sprinters who have trained 2-3 h/day, 5 days/week, for at least 3 years compared with untrained men, although the VO2 max was markedly greater in sprinters. Thus, there is a case that daily training was not sufficient to improve sweating function in sprinters relative to those in distance runners.

  17. Working in a hot environment; perspiration loss; a drink for persons working under hot conditions, part 2

    Science.gov (United States)

    Glatzel, H.

    1978-01-01

    Losses of various nutrients through sweat of persons working under hot conditions were considered. On the basis of these considerations a supplemental drink was formulated consisting of 1 liter of water per hour containing salt, potassium chloride, iron, thiamine and ascorbic acid.

  18. Chloride and potassium conductances of cultured human sweat ducts

    DEFF Research Database (Denmark)

    Novak, I; Pedersen, P S; Larsen, Erik Hviid

    1992-01-01

    The purpose of this study was to characterize the ion conductances, in particular those for Cl- and K+, of human sweat duct cells grown in primary culture. Sweat duct cells from healthy individuals were grown to confluence on a dialysis membrane, which was then mounted in a mini-Ussing chamber...

  19. Sweat chloride concentrations in children with Idiopathic Nephrotic Syndrome.

    Science.gov (United States)

    Guglani, Lokesh; Moir, Devin; Jain, Amrish

    2016-01-01

    Idiopathic Nephrotic Syndrome (INS) has been believed to cause a false positive elevation of sweat chloride concentrations, as measured by the sweat test. Sweat tests were done for 11 children with acute onset INS at admission and again while they were in remission, with results being compared to normal historical controls. The initial sweat chloride concentration for 10 patients was normal (mean16.7 ± 11.02 mmol/L) and 1 patient had inadequate collection. This latter patient and two others were excluded during follow-up because of diagnoses other than INS. Sweat test results for the eight INS patients during follow up remained unchanged when they were in remission (16.94 ± 7.88 mmol/L; P = 0.98; Wilcoxon Matched-Pairs Signed Rank Test). In comparing sweat chloride concentrations from INS patients to those from 20 historical control subjects, we found no significant differences (Mann-Whitney Test; initial vs. control P = 0.643; follow up vs. control P = 0.806). INS does not cause a false positive sweat test. Further studies should be done to objectively assess the conditions that have been reported to affect sweat chloride concentrations. © 2015 Wiley Periodicals, Inc.

  20. Equine sweat composition: effects of adrenaline infusion, exercise and training.

    Science.gov (United States)

    McConaghy, F F; Hodgson, D R; Evans, D L; Rose, R J

    1995-11-01

    Significant alterations in plasma electrolyte concentrations have been reported in horses following prolonged exercise, resulting from loss of hypertonic sweat. Sweat was collected from 10 horses undergoing a 10 week training programme; 5 at moderate intensity, to speeds of 10 m/s and 5 at low intensity, to speeds of 5 m/s. Sweat was collected from 2 sites in response to a submaximal exercise test (30 min at 50% VO2max and during an adrenaline infusion (dose mean +/- s.d.; 0.3 +/- 0.05 g/kg over 30 min). Sweat samples were analysed for sodium, chloride, potassium, protein, magnesium, calcium and urea concentrations. Sweat produced in response to exercise and adrenaline infusion was hypertonic and showed no significant differences in composition following training. However, the [NaCl] of sweat rose with increased duration of sweating. Sweat produced in response to adrenaline infusion was more dilute than that produced in response to exercise, which may be related to sympathetic outflow during exercise.

  1. [Estimation of the sweat composition of fatty acids].

    Science.gov (United States)

    Solovskaia, S S; Varus, V I; Briuzgina, T S; Belov, A A; Ivanov, D A

    2007-05-01

    Changes in the fatty acid composition of sweat lipid were studied in persons whose activity was associated with military service. There were significant changes in essential fatty acids of sweat lipids, which made it possible to use this noninvasive biological object as a criterion for rating dysadaptive processes in armed forces personnel.

  2. Hot Flashes among Prostate Cancer Patients Undergoing Androgen Deprivation Therapy: Psychosocial and Quality of Life Issues

    Science.gov (United States)

    2006-12-01

    and the menstrual cycle on hot flash-related thermoregulatory parameters. Menopause-The Journal of the North American Menopause Society, 12(2), 156...Kuwahara, T., Ogura, Y., & Ueda, H. (2005). Sex- and menstrual cycle -related differences in sweating and cutaneous blood flow in response to...on aerobic capability ( VO2max ) and surface area-to-weight ratio (Frye & Kamon, 1981). Young men had significantly greater sweat rates on the chest

  3. Hydration: special issues for playing football in warm and hot environments.

    Science.gov (United States)

    Shirreffs, S M

    2010-10-01

    The high metabolic rates and body temperatures sustained by football players during training and matches causes sweating--particularly when in warm or hot environments. There is limited published data on the effects of this sweat loss on football performance. The limited information available, together with knowledge of the effects of sweat loss in other sports with skill components as well as endurance and sprint components, suggests that the effects of sweating will be similar as in these other activities. Therefore, the generalization that, on average, a body mass reduction equivalent to 2% should be the acceptable limit of sweat losses seems reasonable. This magnitude and more, of sweat loss is a common occurrence for some players. Sodium is the main electrolyte lost in sweat but there is large variability in sodium losses between players. However, the extent of sodium losses in some players may be such that its replacement is warranted for these players. Although football is a team sport, the great individual variability in sweat and electrolyte losses of players in the same training session or match dictates that individual monitoring to determine individual water and electrolyte requirements should be an essential part of a player's nutrition strategy. © 2010 John Wiley & Sons A/S.

  4. Composition of the secretion from the eccrine sweat glands of the cat's foot pad.

    Science.gov (United States)

    Foster, K G

    1966-05-01

    1. The sweat composition from the cat's foot pad was examined at various rates of secretion. Sodium pentobarbitone or chloralose anaesthesia were used.2. Cat's pad sweat contains lactate, glucose is almost absent, and the sodium and chloride concentrations increased with increasing sweat rate. In these respects the secretion resembles human eccrine sweat.3. The sodium, chloride, and potassium concentrations are much higher than in human sweat; also the potassium level decreased with increasing rate. Consequently, whereas human sweat is hypotonic with respect to the plasma, cat's pad sweat is slightly hypertonic with respect to the plasma even at low rates of secretion. In contrast to human sweat glands, which produce a slightly acidic secretion containing ammonia, cat's pad sweat glands produce an alkaline secretion containing bicarbonate. Also in contrast to human sweat, lactate levels decreased with increasing sweat rate.

  5. Improved Devices for Collecting Sweat for Chemical Analysis

    Science.gov (United States)

    Feeback, Daniel L.; Clarke, Mark S. F.

    2011-01-01

    Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available

  6. Effect of salt supplementation on the rate of inadequate sweat collection for infants less than 3 months of age referred for the sweat test.

    Science.gov (United States)

    Guglani, Lokesh; Abdulhamid, Ibrahim

    2015-01-01

    Sweat testing in young infants (≤ 3 months) with a positive newborn screen for Cystic Fibrosis (CF) can yield higher rates of inadequate sweat collection. The role of salt supplements in improving sweat collection has not been studied before. All young infants referred to our CF center for sweat testing were randomized to either receive salt supplements {1/8th teaspoon salt (750 mg)} mixed in formula feeds 1 day prior to sweat testing (study group) or no salt supplement (controls). Of the 151 young infants that underwent sweat testing over 18 months, 75 received salt supplements, while 76 did not. A total of 9 (11.8%) infants in the salt supplement group had inadequate sweat collection, as compared to 4 (5.2%) infants in the control group (p = 0.16, Fisher's Exact Test). Oral salt supplementation for young infants prior to sweat testing does not help to reduce the rates of inadequate sweat collection.

  7. Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics

    Science.gov (United States)

    Munje, Rujuta D.; Muthukumar, Sriram; Panneer Selvam, Anjan; Prasad, Shalini

    2015-09-01

    An ultra-sensitive and highly specific electrical double layer (EDL) modulated biosensor, using nanoporous flexible substrates for wearable diagnostics is demonstrated with the detection of the stress biomarker cortisol in synthetic and human sweat. Zinc oxide thin film was used as active region in contact with the liquid i.e. synthetic and human sweat containing the biomolecules. Cortisol detection in sweat was accomplished by measuring and quantifying impedance changes due to modulation of the double layer capacitance within the electrical double layer through the application of a low orthogonally directed alternating current (AC) electric field. The EDL formed at the liquid-semiconductor interface was amplified in the presence of the nanoporous flexible substrate allowing for measuring the changes in the alternating current impedance signal due to the antibody-hormone interactions at diagnostically relevant concentrations. High sensitivity of detection of 1 pg/mL or 2.75 pmol cortisol in synthetic sweat and 1 ng/mL in human sweat is demonstrated with these novel biosensors. Specificity in synthetic sweat was demonstrated using a cytokine IL-1β. Cortisol detection in human sweat was demonstrated over a concentration range from 10-200 ng/mL.

  8. The effect of heat acclimation on sweat microminerals: Artifact of surface contamination

    Science.gov (United States)

    Heat acclimation (HA) reportedly conveys conservation in sweat micromineral concentrations when sampled from arm sweat, but time course is unknown. The observation that comprehensive cleaning of the skin surface negates sweat micromineral reductions during prolonged sweating raises the question of w...

  9. Sweat rate and fluid intake in young elite basketball players on the FIBA Europe U20 Championship

    Directory of Open Access Journals (Sweden)

    Vukašinović-Vesić Milica

    2015-01-01

    Full Text Available Background/Aim. Previous investigations in many sports indicated that continued exercise, especially in hot environments, can cause high sweat rate and huge water and electrolyte losses, thus impairing the performance of athletes. Most these studies were conducted during training sessions, but rarely during an official competition. Therefore, the aim of our study was to determine pre- and post-competition hydration, fluid intake and sweat loss of young elite basketball players during the FIBA Europe U20 Championship. Methods. The study included 96 basketball male players, (19 ± 0.79 years of eight national teams. Ambient temperature was 30 ± 2ºC, humidity 55 ± 4% and the mean playing time in game 18.8 ± 10.5 min. The following parameters related to hydration status were measured: fluid intake, urine output, sweat rate, percent of dehydration, urine parameters (specific gravity, color and osmolarity, body mass and body surface area. Results. We found that the mean fluid intake was 1.79 ± 0.8 L/h, sweat rate 2.7 ± 0.9 L/h, urine output 55 ± 61 mL and the percentage of dehydration 0.99 ± 0.7%. According to urine osmolarity more than 75% of players were dehydrated before the game and the process continued during the game. The difference in body mass (0.9 ± 0.7 kg before and after the game was statistically significant. There were statistically significant correlations between the sweat rate and fluid intake, urine osmolarity, body mass loss, body surface area and percentage of dehydration. Fluid intake correlated with the percentage of dehydration, body mass loss, urine specific gravity and urine color. The sweat rate, which varied between the teams, was the highest for centers when this parameter was calculated on the effective time in game. Conclusion. Most of the athletes start competition dehydrated, fail to compensate sweat loss during the game and continue to be dehydrated, regardless what kind of drink was used. These results

  10. Night sweats, sleep disturbance, and depression associated with diminished libido in late menopausal transition and early postmenopause: baseline data from the Herbal Alternatives for Menopause Trial (HALT).

    Science.gov (United States)

    Reed, Susan D; Newton, Katherine M; LaCroix, Andrea Z; Grothaus, Lou C; Ehrlich, Kelly

    2007-06-01

    The objective of the study was to evaluate the association of depression, sleep disturbance, and menopausal symptoms with diminished libido. Data from a 2001-2002 baseline survey of 341 peri- and postmenopausal women, aged 45-55 years, participating in a randomized trial, was analyzed. Eligibility included at least 2 hot flashes and/or night sweats per day and no hormone therapy for at least the prior 3 months. The survey evaluated sexual function, depression, sleep, and vasomotor symptoms. We examined the association between these factors, using multivariate regression models. Of 341 women, 64% had diminished libido, 18% had moderate to severe depression, and 43% had poor sleep quality. Women averaged 4.6 hot flashes and 1.9 night sweats per day. Depressive symptoms (P = .003), poor sleep (P = .02), and night sweats (P = .04) were significantly associated with diminished libido. Factors associated with diminished libido in midlife are complex but include depression, disturbed sleep, and night sweats, all common symptoms of the menopausal transition and early menopause.

  11. Genetics Home Reference: cold-induced sweating syndrome

    Science.gov (United States)

    ... my area? Other Names for This Condition CISS CNTF receptor-related disorders Crisponi syndrome Sohar-Crisponi syndrome ... of cardiotrophin-like cytokine, a second ligand for ciliary neurotrophic factor receptor, leads to cold-induced sweating syndrome in ...

  12. Cystic fibrosis with normal sweat chloride concentration: case report

    Directory of Open Access Journals (Sweden)

    Silva Filho Luiz Vicente Ferreira da

    2003-01-01

    Full Text Available Cystic fibrosis is a genetic disease usually diagnosed by abnormal sweat testing. We report a case of an 18-year-old female with bronchiectasis, chronic P. aeruginosa infection, and normal sweat chloride concentrations who experienced rapid decrease of lung function and clinical deterioration despite treatment. Given the high suspicion ofcystic fibrosis, broad genotyping testing was performed, showing a compound heterozygous with deltaF508 and 3849+10kb C->T mutations, therefore confirming cystic fibrosis diagnosis. Although the sweat chloride test remains the gold standard for the diagnosis of cystic fibrosis, alternative diagnostic tests such as genotyping and electrophysiologic measurements must be performed if there is suspicion of cystic fibrosis, despite normal or borderline sweat chloride levels.

  13. Sweat Gland Progenitors in Development, Homeostasis, and Wound Repair

    Science.gov (United States)

    Lu, Catherine; Fuchs, Elaine

    2014-01-01

    The human body is covered with several million sweat glands. These tiny coiled tubular skin appendages produce the sweat that is our primary source of cooling and hydration of the skin. Numerous studies have been published on their morphology and physiology. Until recently, however, little was known about how glandular skin maintains homeostasis and repairs itself after tissue injury. Here, we provide a brief overview of sweat gland biology, including newly identified reservoirs of stem cells in glandular skin and their activation in response to different types of injuries. Finally, we discuss how the genetics and biology of glandular skin has advanced our knowledge of human disorders associated with altered sweat gland activity. PMID:24492848

  14. \\'Sweat Equity\\': Women\\'s Participation in Subsidised Housing in ...

    African Journals Online (AJOL)

    Abstract. The notion of \\"sweat equity\\" has been promoted as an integral part of subsidised housing in South African Housing policy. It\\'s tougher for females, though. Africa Insight Vol.34(2/3) 2004: 58-64 ...

  15. Influence of sex and growth hormone deficiency on sweating

    DEFF Research Database (Denmark)

    Main, K; Nilsson, K O; Skakkebaek, N E

    1991-01-01

    Sweat secretion rate (SSR) was measured by the pilocarpine iontophoresis test in (a) 254 healthy children and adolescents (aged 6.0 to 19.2 years, mean age 11.2 years); in (b) 58 healthy adults (aged 20.4 to 75.2 years, mean age 37.6 years); and in (c) eight prepubertal patients with growth hormone...... in sweat excretion rate from childhood to adulthood showed a difference between the sexes. Both pre-pubertal and pubertal boys had a lower secretion value than adult men (p less than 0.001 and 0.01, respectively), whereas girls showed higher secretion values than adult women (p less than 0.01 and p less...... min-1). We conclude that (a) sweat secretion pattern in children shows a significant sex difference and (b) sweating in children is dependent on growth hormone....

  16. Lack of harmonization in sweat testing for cystic fibrosis

    DEFF Research Database (Denmark)

    Lindegaard Christiansen, Anne; Nybo, Mads

    2014-01-01

    Abstract Introduction. Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study...... fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use....... a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. Conclusion. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic...

  17. Observation of the sweating in lipstick by scanning electron microscopy.

    Science.gov (United States)

    Seo, S Y; Lee, I S; Shin, H Y; Choi, K Y; Kang, S H; Ahn, H J

    1999-06-01

    The relationship between the wax matrix in lipstick and sweating has been investigated by observing the change of size and shape of the wax matrix due to sweating by Scanning Electron Microscopy (SEM). For observation by SEM, a lipstick sample was frozen in liquid nitrogen. The oil in the lipstick was then extracted in cold isopropanol (-70 degrees C) for 1-3 days. After the isopropanol was evaporated, the sample was sputtered with gold and examined by SEM. The change of wax matrix underneath the surface from fine, uniform structure to coarse, nonuniform structure resulted from the caking of surrounding wax matrix. The oil underneath the surface migrated to the surface of lipstick with sweating; consequently the wax matrix in that region was rearranged into the coarse matrix. In case of flamed lipstick, sweating was delayed and the wax matrix was much coarser than that of the unflamed one. The larger wax matrix at the surface region was good for including oil. The effect of molding temperature on sweating was also studied. As the molding temperature rose, sweating was greatly reduced and the size of the wax matrix increased. It was found that sweating was influenced by the compatibility of wax and oil. A formula consisting of wax and oil that have good compatibility has a tendency to reduce sweating and increase the size of the wax matrix. When pigments were added to wax and oil, the size of the wax matrix was changed, but in all cases sweating was increased due to the weakening of the binding force between wax and oil. On observing the thick membrane of wax at the surface of lipstick a month after molding it was also found that sweating was influenced by ageing. In conclusion, the structure of the wax matrix at the surface region of lipstick was changed with the process of flaming, molding temperature, compatibility of wax and oil, addition of pigment, and ageing. In most cases, as the size of the wax matrix was increased, sweating was reduced and delayed.

  18. Metabolomics analysis of human sweat collected after moderate exercise.

    Science.gov (United States)

    Delgado-Povedano, M M; Calderón-Santiago, M; Luque de Castro, M D; Priego-Capote, F

    2018-01-15

    Sweat is a promising biofluid scarcely used in clinical analysis despite its non-invasive sampling. A more frequent clinical use of sweat requires to know its whole composition, especially concerning to non-polar compounds, and the development of analytical strategies for its characterization. The aim of the present study was to compare different sample preparation strategies to maximize the detection of metabolites in sweat from humans collected after practicing moderate exercise. Special emphasis was put on non-polar compounds as they have received scant attention in previous studies dealing with this biofluid. Sample preparation by liquid-liquid extraction (LLE) using extractants with different polarity index was compared to deproteination. Then, derivatization by methoxymation with subsequent silylation was compared to direct analysis of sweat extracts to check the influence of derivatization on the subsequent determination of volatile organic compounds (VOCs). 135 compounds were tentatively identified by combining spectral and retention time information after analysis by gas chromatography coupled to mass spectrometry in high resolution mode (GC-TOF/MS). Lipids, VOCs, benzenoids and other interesting metabolites such as alkaloids and ethanolamines were identified. Among the tested protocols, methyoxiamination plus silylation after LLE with dichloromethane was the best option to obtain a representative snapshot of sweat metabolome collected from different body parts after moderate exercise. Passive and active sweat pools from a cohort of volunteers (n = 6) were compared to detect compositional differences which can be explained by the sampling process and sweating induction. As most of the identified compounds are metabolites involved in key biochemical pathways, this study opens new opportunities to extend the applicability of human sweat as a source of metabolite biomarkers of pathologies or specific processes such as dehydration or nutritional unbalance

  19. Operational test of bonded magnetocaloric plates

    DEFF Research Database (Denmark)

    Bahl, Christian; Navickaité, Kristina; Neves Bez, Henrique

    2017-01-01

    Bonded plates made by hot pressing La0.85Ce0.15Fe11.25Mn0.25Si1.5Hy particles and resin have been tested as active magnetic regenerators in a small scale magnetocaloric device. Firstly the plates were carefully characterised magnetically and thermally. The plates were prepared with 5 wt% resin......, and from density measurements it was found that the volume ratio of the magnetocaloric material in the plates was 0.53, due to the resin and porosity. The best operating conditions for the plate regenerator were determined at which a temperature span of 6.4 K was measured along the plates....

  20. Sweat lipid mediator profiling: a noninvasive approach for cutaneous research.

    Science.gov (United States)

    Agrawal, Karan; Hassoun, Lauren A; Foolad, Negar; Pedersen, Theresa L; Sivamani, Raja K; Newman, John W

    2017-01-01

    Recent advances in analytical and sweat collection techniques provide new opportunities to identify noninvasive biomarkers for the study of skin inflammation and repair. This study aims to characterize the lipid mediator profile including oxygenated lipids, endocannabinoids, and ceramides/sphingoid bases in sweat and identify differences in these profiles between sweat collected from nonlesional sites on the unflared volar forearm of subjects with and without atopic dermatitis (AD). Adapting routine procedures developed for plasma analysis, over 100 lipid mediators were profiled using LC-MS/MS and 58 lipid mediators were detected in sweat. Lipid mediator concentrations were not affected by sampling or storage conditions. Increases in concentrations of C30-C40 [NS] and [NdS] ceramides, and C18:1 sphingosine, were observed in the sweat of study participants with AD despite no differences being observed in transepidermal water loss between study groups, and this effect was strongest in men (P Sweat mediator profiling may therefore provide a noninvasive diagnostic for AD prior to the presentation of clinical signs.

  1. Trapped sweat in basketball uniforms and the effect on sweat loss estimates.

    Science.gov (United States)

    Baker, Lindsay B; Reimel, Adam J; Sopeña, Bridget C; Barnes, Kelly A; Nuccio, Ryan P; De Chavez, Peter John D; Stofan, John R; Carter, James M

    2017-09-01

    The aims of this study were to determine: (1) trapped sweat (TS) in basketball uniforms and the effect on sweat loss (SL) estimates during a laboratory-based basketball simulation protocol; (2) the impact of exercise intensity, body mass, age, and SL on TS; and (3) TS during on-court training to assess the ecological validity of the laboratory-based results. Twenty-four recreational/competitive male basketball players (23 ± 10 years, 77.0 ± 16.7 kg) completed three randomized laboratory-based trials (Low, Moderate, and High intensity) consisting of 150-min intermittent exercise. Eighteen elite male players (23 ± 4 years, 92.0 ± 20.6 kg) were observed during coach-led, on-court training. Nude and clothed body mass were measured pre and postexercise to determine TS. Data are mean ± SD. There was a significant effect of intensity on SL and TS ( P  < 0.001, Lowsweat and TS was 0.11 ± 0.15 kg (8.0 ± 5.1% SL). During Moderate, subjects lost 1.60 ± 0.56 kg sweat and TS was 0.21 ± 0.21 kg (11.6 ± 6.3% SL). During High, subjects lost 2.12 ± 0.66 kg sweat and TS was 0.38 ± 0.28 kg (16.0 ± 7.4% SL). Multiple regression and partial correlation analysis suggested TS was significantly related to SL ( P  < 0.0001; partial r  = 0.81-0.89), whereas the contributions of body mass ( P  = 0.22-0.92) and age ( P  = 0.29-0.44) were not significant. TS during on-court training was 0.35 ± 0.36 kg, which was associated with a 14.1 ± 11.5% underestimation in SL, and was not statistically different than laboratory-based results ( P  = 0.59). Clothed body mass measurements should be used with caution, as TS is highly variable and can cause a significant underestimation in SL in athletes with high sweating rates. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological

  2. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  3. Matrigel basement membrane matrix induces eccrine sweat gland cells to reconstitute sweat gland-like structures in nude mice.

    Science.gov (United States)

    Li, Haihong; Chen, Lu; Zeng, Shaopeng; Li, Xuexue; Zhang, Xiang; Lin, Changmin; Zhang, Mingjun; Xie, Sitian; He, Yunpu; Shu, Shenyou; Yang, Lvjun; Tang, Shijie; Fu, Xiaobing

    2015-03-01

    Severe burn results in irreversible damage to eccrine sweat glands, for which no effective treatment is available. Interaction between the extracellular matrix and epithelial cells is critical for proper three-dimensional organization and function of the epithelium. Matrigel-embedded eccrine sweat gland cells were subcutaneously implanted into the inguinal regions of nude mice. Two weeks later, the Matrigel plugs were removed and evaluated for series of detection items. Sweat gland cells developed into sweat gland-like structures in the Matrigel plugs based on: (1) de novo formation of tubular-like structures with one or more hollow lumens, (2) expression of epithelial and sweat gland markers (pancytokeratin, CK5/7/14/19, α-SMA and CEA), (3) basement membrane formation, (4) myoepithelial cells presenting in and encompassing the tubular-like structures, (5) cellular polarization, evident by the expression of tight junction proteins (claudin-1 and ZO-2), anchoring junctions (desmoglein-1 and -2 and E-cadherin) and CEA in the luminal membrane, (6) expression of proteins related to sweat secretion and absorption (Na(+)-K(+)-ATPase α/β, Na(+)-K(+)-2Cl-cotranspoter 1, Na(+)/H(+) exchanger 1, aquaporin-5, epithelial sodium channel, cystic fibrosis transmembrane conductance regulator, potassium channel and vacuolar-type H+-ATPase), and (7) about 20% of the tubular-like structures are de novo coils and 80% are de novo ducts. This study provides not only an excellent model to study eccrine sweat gland development, cytodifferentiation and reconstitution, but also an in vivo model for regeneration of eccrine sweat glands. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Sweat Farm Road Fire in Georgia

    Science.gov (United States)

    2007-01-01

    Dense plumes of blue-white smoke billowed from the Sweat Farm Road Fire in southern Georgia on April 19, 2007, when the Landsat 5 satellite captured this detailed image. The fire started on April 16, when a tree fell on a power line and, fanned by strong winds, quickly exploded into a major fire. By April 19, the fire had forced officials to close several roads, including U.S. Highway 1, and to evacuate hundreds of people from the perimeter of the city of Waycross, the silver cluster along the top edge of the image. The nearness of the fire is evident in the dark brown, charred land just south of the city. The active fire front is along the south edge of the burned area, where the flames are eating into the dark green hardwood forests, pine plantations, and shrubs in Okefenokee Swamp. Because of the difficult terrain, the fire and the adjoining Big Turnaround Complex fire are expected to burn until significant rain falls, said the morning report issued by the Southern Area Coordination Center on May 4. 'In the long term, the burning of the swamp will ultimately benefit the swamp wilderness habitat, which is a fire-dependent ecosystem,' said a press release issued from the Okefenokee National Wildlife Refuge on May 4. Such ecosystems require fire to remain healthy. In the case of southern pine forests, many pine species need fire to remove litter from the ground and release soil nutrients so that new seedlings can grow.

  5. Claudin-3 loss causes leakage of sweat from the sweat gland to contribute to the pathogenesis of atopic dermatitis.

    Science.gov (United States)

    Yamaga, Kosuke; Murota, Hiroyuki; Tamura, Atsushi; Miyata, Hirofumi; Ohmi, Masato; Kikuta, Junichi; Ishii, Masaru; Tsukita, Sachiko; Katayama, Ichiro

    2017-12-22

    The transfer of sweat to the skin surface without leakage is important for the homeostatic regulation of skin and is impaired in atopic dermatitis (AD). Although the precise composition of the leakage barrier remains obscure, there is a large contribution from claudins, the major components of tight junctions. In humans, claudin-1, -3, and -15 are expressed on sweat ducts, and claudin-3 and -10 are expressed on secretory coils. Although only two claudins are expressed in murine sweat glands, we found that the expression of claudin-3 is conserved. AD lesional skin had decreased claudin-3 expression in sweat glands, which was accompanied by sweat leakage. This critical role in water barrier function was confirmed in Cldn3 -/- and Cldn3 +/- mice and those with experimentally decreased claudin-3. Our results reveal the crucial role of claudin-3 in preventing sweat gland leakage and suggest that the pathogenesis of dermatoses accompanied by hypohidrosis involves abnormally decreased claudin-3. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring.

    Science.gov (United States)

    Brueck, Andrew; Iftekhar, Tashfin; Stannard, Alicja B; Yelamarthi, Kumar; Kaya, Tolga

    2018-02-10

    There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 µL/min/cm², with an average error in accuracy of 18% compared to manual sweat rate readings.

  7. Hot Flashes

    Science.gov (United States)

    ... Risk factors Not all women who go through menopause have hot flashes, and it's not clear why some women do have them. Factors that may increase your risk include: Smoking. Women who smoke are more likely to get hot flashes. Obesity. A high body mass index (BMI) is associated ...

  8. Solar Hot Water Heater

    Science.gov (United States)

    1978-01-01

    The solar panels pictured below, mounted on a Moscow, Idaho home, are part of a domestic hot water heating system capable of providing up to 100 percent of home or small business hot water needs. Produced by Lennox Industries Inc., Marshalltown, Iowa, the panels are commercial versions of a collector co-developed by NASA. In an effort to conserve energy, NASA has installed solar collectors at a number of its own facilities and is conducting research to develop the most efficient systems. Lewis Research Center teamed with Honeywell Inc., Minneapolis, Minnesota to develop the flat plate collector shown. Key to the collector's efficiency is black chrome coating on the plate developed for use on spacecraft solar cells, the coating prevents sun heat from "reradiating," or escaping outward. The design proved the most effective heat absorber among 23 different types of collectors evaluated in a Lewis test program. The Lennox solar domestic hot water heating system has three main components: the array of collectors, a "solar module" (blue unit pictured) and a conventional water heater. A fluid-ethylene glycol and water-is circulated through the collectors to absorb solar heat. The fluid is then piped to a double-walled jacket around a water tank within the solar module.

  9. Systematic review focusing on the excretion and protection roles of sweat in the skin.

    Science.gov (United States)

    Peng, Yan; Cui, Xiao; Liu, Yanhua; Li, Yaoyin; Liu, Jian; Cheng, Biao

    2014-01-01

    The skin excretes substances primarily through sweat glands. Several conditions have been demonstrated to be associated with diminished sweating. However, few studies have concentrated on the metabolism and excretion of sweat. This review focuses on the relationship between temperature and the thermoregulatory efficacy of sweat, and then discusses the excretion of sweat, which includes the metabolism of water, minerals, proteins, vitamins as well as toxic substances. The potential role of sweat secretion in hormone homeostasis and the effects on the defense system of the skin are also clarified. © 2014 S. Karger AG, Basel.

  10. Human Elimination of Organochlorine Pesticides: Blood, Urine, and Sweat Study.

    Science.gov (United States)

    Genuis, Stephen J; Lane, Kevin; Birkholz, Detlef

    2016-01-01

    Background . Many individuals have been exposed to organochlorinated pesticides (OCPs) through food, water, air, dermal exposure, and/or vertical transmission. Due to enterohepatic reabsorption and affinity to adipose tissue, OCPs are not efficiently eliminated from the human body and may accrue in tissues. Many epidemiological studies demonstrate significant exposure-disease relationships suggesting OCPs can alter metabolic function and potentially lead to illness. There is limited study of interventions to facilitate OCP elimination from the human body. This study explored the efficacy of induced perspiration as a means to eliminate OCPs. Methods . Blood, urine, and sweat (BUS) were collected from 20 individuals. Analysis of 23 OCPs was performed using dual-column gas chromatography with electron-capture detectors. Results . Various OCPs and metabolites, including DDT, DDE, methoxychlor, endrin, and endosulfan sulfate, were excreted into perspiration. Generally, sweat samples showed more frequent OCP detection than serum or urine analysis. Many OCPs were not readily detected in blood testing while still being excreted and identified in sweat. No direct correlation was found among OCP concentrations in the blood, urine, or sweat compartments. Conclusions . Sweat analysis may be useful in detecting some accrued OCPs not found in regular serum testing. Induced perspiration may be a viable clinical tool for eliminating some OCPs.

  11. Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes.

    Science.gov (United States)

    Rose, Daniel P; Ratterman, Michael E; Griffin, Daniel K; Hou, Linlin; Kelley-Loughnane, Nancy; Naik, Rajesh R; Hagen, Joshua A; Papautsky, Ian; Heikenfeld, Jason C

    2015-06-01

    Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive radio-frequency identification (RFID) sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of solutes in sweat, and surface temperature, as read by an Android smartphone app with 96% accuracy at 50 mM Na(+) (in vitro tests). All circuitry is solder-reflow integrated on a standard Cu/polyimide flexible-electronic layer including an antenna, but while also allowing electroplating for simple integration of exotic metals for sensing electrodes. Optional paper microfluidics wick sweat from a sweat porous adhesive allowing flow to the sensor, or the sensor can be directly contacted to the skin. The wearability of the patch has been demonstrated for up to seven days, and includes a protective textile which provides a feel and appearance similar to a standard Band-Aid. Applications include hydration monitoring, but the basic capability is extendable to other mM ionic solutes in sweat (Cl(-), K(+), Mg(2+), NH4(+), and Zn(2+)). The design and fabrication of the patch are provided in full detail, as the basic components could be useful in the design of other wearable sensors.

  12. Early-stage mucinous sweat gland adenocarcinoma of eyelid

    Directory of Open Access Journals (Sweden)

    Nizawa T

    2011-05-01

    Full Text Available Tomohiro Nizawa1, Toshiyuki Oshitari1, Ryuta Kimoto1, Fusae Kajita1, Jiro Yotsukura1, Kaoru Asanagi1, Takayuki Baba1, Yoko Takahashi2, Takashi Oide2, Takako Kiyokawa2, Takashi Kishimoto2, Shuichi Yamamoto11Department of Ophthalmology and Visual Science, 2Department of Molecular Pathology, Chiba University Graduate School of Medicine, Chuo-ku, Chiba, JapanAbstract: We present the findings of an early-stage primary mucinous sweat gland adenocarcinoma in the lower eyelid of a Japanese patient. The patient was a 73-year-old man who had had a nodule on the left lower eyelid for two years. He was referred to our hospital with a diagnosis of a swollen chalazion. The clinical and histopathological records were reviewed and the mass was excised. Histopathological examination revealed a mucinous sweat gland adenocarcinoma. Postoperative magnetic resonance imaging and positron emission tomography excluded systemic metastases. After the histopathological findings, a complete surgical excision of the margins of the adenocarcinoma was performed, with histopathological confirmation of negative margins. After the final histopathological examination, the patient was diagnosed with a primary mucinous sweat gland adenocarcinoma of the left eyelid. Six months after the surgery, no recurrence has been observed. Because the appearance of mucinous sweat gland adenocarcinoma of the eyelid is quite variable, the final diagnosis can only be made by histopathological examination. A complete surgical excision is recommended.Keywords: complete surgical excision, eyelid, initial stage, mucinous sweat gland adenocarcinoma

  13. Sweat mineral-element responses during 7 h of exercise-heat stress.

    Science.gov (United States)

    Montain, Scott J; Cheuvront, Samuel N; Lukaski, Henry C

    2007-12-01

    Uncertainty exists regarding the effect of sustained sweating on sweat mineral-element composition. To determine the effect of multiple hours of exercise-heat stress on sweat mineral concentrations. Seven heat-acclimated subjects (6 males, 1 female) completed 5 x 60 min of treadmill exercise (1.56 m/s, 2% grade) with 20 min rest between exercise periods in 2 weather conditions (27 degrees C, 40% relative humidity, 1 m/s and 35 degrees C, 30%, 1 m/s). Sweat was collected from a sweat-collection pouch attached to the upper back during exercise bouts 1, 3, and 5. Mineral elements were determined by using inductively coupled plasma-emission spectrography. At 27 degrees C, sweat sodium (863 [563] microg/mL; mean [SD]), potassium (222 [48] microg/mL), calcium (16 [7]) microg/mL), magnesium (1265 [566] ng/mL), and copper (80 [56] ng/mL) remained similar to baseline over 7 h of exercise-heat stress, whereas sweat zinc declined 42-45% after the initial hour of exercise-heat stress (Ex1 = 655 [362], Ex3 = 382 [168], Ex5 = 355 [288] microg/mL, P sweat zinc at 35 degrees C when sweat rates were higher. Sweat rate had no effect on sweat trace-element composition. Sweat sodium, potassium, and calcium losses during multiple hours of sustained sweating can be predicted from initial sweat composition. Estimates of sweat zinc losses, however, will be overestimated if sweat zinc conservation is not accounted for in sweat zinc-loss estimates.

  14. Sweat, the driving force behind normal skin: an emerging perspective on functional biology and regulatory mechanisms.

    Science.gov (United States)

    Murota, Hiroyuki; Matsui, Saki; Ono, Emi; Kijima, Akiko; Kikuta, Junichi; Ishii, Masaru; Katayama, Ichiro

    2015-01-01

    The various symptoms associated with excessive or insufficient perspiration can significantly reduce a patient's quality of life. If a versatile and minimally invasive method could be established for returning sweat activity to normalcy, there is no question that it could be used in the treatment of many diseases that are believed to involve perspiration. For this reason, based on an understanding of the sweat-gland control function and sweat activity, it was necessary to conduct a comprehensive search for the factors that control sweating, such as the central and peripheral nerves that control sweat-gland function, the microenvironment surrounding the sweat glands, and lifestyle. We focused on the mechanism by which atopic dermatitis leads to hypohidrosis and confirmed that histamine inhibits acetylcholinergic sweating. Acetylcholine promotes the phosphorylation of glycogen synthesis kinase 3β (GSK3β) in the sweat-gland secretory cells and leads to sensible perspiration. By suppressing the phosphorylation of GSK3β, histamine inhibits the movement of sweat from the sweat-gland secretory cells through the sweat ducts, which could presumably be demonstrated by dynamic observations of the sweat glands using two-photon microscopy. It is expected that the discovery of new factors that control sweat-gland function can contribute to the treatment of diseases associated with dyshidrosis. Copyright © 2014 Japanese Society for Investigative Dermatology. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Acquired defects in CFTR-dependent β-adrenergic sweat secretion in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Courville, Clifford A; Tidwell, Sherry; Liu, Bo; Accurso, Frank J; Dransfield, Mark T; Rowe, Steven M

    2014-02-25

    Smoking-induced chronic obstructive pulmonary disease (COPD) is associated with acquired systemic cystic fibrosis transmembrane conductance regulator (CFTR) dysfunction. Recently, sweat evaporimetry has been shown to efficiently measure β-adrenergic sweat rate and specifically quantify CFTR function in the secretory coil of the sweat gland. To evaluate the presence and severity of systemic CFTR dysfunction in smoking-related lung disease using sweat evaporimetry to determine CFTR-dependent sweat rate. We recruited a cohort of patients consisting of healthy never smokers (N = 18), healthy smokers (12), COPD smokers (25), and COPD former smokers (12) and measured β-adrenergic sweat secretion rate with evaporative water loss, sweat chloride, and clinical data (spirometry and symptom questionnaires). β-adrenergic sweat rate was reduced in COPD smokers (41.9 ± 3.4, P sweat chloride was significantly greater in COPD smokers (32.8 ± 3.3, P sweat rate and female gender (β = 0.26), age (-0.28), FEV1% (0.35), dyspnea (-0.3), and history of smoking (-0.27; each P sweat rate was significantly reduced in COPD patients, regardless of smoking status, reflecting acquired CFTR dysfunction and abnormal gland secretion in the skin that can persist despite smoking cessation. β-adrenergic sweat rate and sweat chloride are associated with COPD severity and clinical symptoms, supporting the hypothesis that CFTR decrements have a causative role in COPD pathogenesis.

  16. Wheelspace windage cover plate for turbine

    Science.gov (United States)

    Lathrop, Norman Douglas

    2002-01-01

    Windage cover plates are secured between the wheels and spacer of a turbine rotor to prevent hot flow path gas ingestion into the wheelspace cavities. Each cover plate includes a linear, axially extending body curved circumferentially with a radially outwardly directed wall at one axial end. The wall defines a axially opening recess for receiving a dovetail lug. The cover plate includes an axially extending tongue received in a circumferential groove of the spacer. The cover plate is secured with the tongue in the groove and dovetail lug in the recess. Lap joints between circumferentially adjacent cover plates are provided.

  17. Excretion of ciprofloxacin in sweat and multiresistant Staphylococcus epidermidis

    DEFF Research Database (Denmark)

    Høiby, N; Jarløv, J O; Kemp, M

    1997-01-01

    BACKGROUND: Staphylococcus epidermidis develops resistance to ciprofloxacin rapidly. That this antibiotic is excreted in apocrine and eccrine sweat of healthy individuals might be the reason for the development of such resistance. We assessed whether S epidermidis isolated from the axilla and nasal...... flora of healthy people could develop resistance to ciprofloxacin after a 1-week course of this antibiotic. METHODS: The concentration of ciprofloxacin in sweat was measured in seven volunteers after oral administration of 750 mg ciprofloxacin twice daily for 7 days, and the development of resistance...... in S epidermidis from axilla and nostrils was monitored during and 2 months after the treatment. Genotyping of S epidermidis was done by restriction fragment length polymorphism. FINDINGS: The mean concentration of ciprofloxacin in sweat increased during the 7 days of treatment-from 2.2 micrograms/mL 2...

  18. Normal sweat chloride test does not rule out cystic fibrosis.

    Science.gov (United States)

    Başaran, Abdurrahman Erdem; Karataş-Torun, Nimet; Maslak, İbrahim Cemal; Bingöl, Ayşen; Alper, Özgül M

    2017-01-01

    Başaran AE, Karataş-Torun N, Maslak İC, Bingöl A, Alper ÖM. Normal sweat chloride test does not rule out cystic fibrosis. Turk J Pediatr 2017; 59: 68-70. A 5-month-old patient presented with complaints of fever and cough. He was hospitalized with the diagnosis of bronchopneumonia and pseudo-Bartter's syndrome. Patient was further investigated for diagnosis of cystic fibrosis. The chloride (Cl) level in sweat was determined within the normal range (25.1 mmol/L, 20.3 mmol/L). CFTR (Cystic Fibrosis Transmembrane Regulator gene; NM_000492.2) genotyping results were positive for p.E92K; p.F1052V mutations. The patient was diagnosed with cystic fibrosis. In our patient, with features of CF and normal sweat test, mutation analysis was helpful for the diagnosis of cystic fibrosis.

  19. Effect of induced metabolic alkalosis on sweat composition in men.

    Science.gov (United States)

    Patterson, M J; Galloway, Stuart D R; Nimmo, M A

    2002-01-01

    To determine whether induced metabolic alkalosis affects sweat composition, 10 males cycled for 90 min at 62.5 +/- 1.3% peak oxygen uptake, on two separate occasions. Subjects ingested either empty capsules (placebo) or capsules containing NaHCO3- (0.3 g kg-1 body mass; six equal doses) over a 2-h period, which commenced 3 h prior to exercise. Arterialized-venous blood samples were drawn prior to and after 15, 30, 60 and 90 min of exercise. Sweat was aspirated at the end of exercise from a patch located on the right scapula region. NaHCO3- ingestion elevated blood pH, [HCO3-] and serum [Na+], whereas serum [Cl-] and [K+] were reduced, both at rest and during exercise (P Sweat pH was greater in the NaHCO3- trial (6.24 +/- 0.18 vs. 6.38 +/- 0.18; P sweat [Na+] (49.5 +/- 4.8 vs. 50.2 +/- 4.3 mEq L-1), [Cl-] (37.5 +/- 5.1 vs. 39.3 +/- 4.2 mEq L-1) and [K+] (4.66 +/- 0.19 vs. 4.64 +/- 0.34 mEq L-1) did not differ between trials (P > 0.05). Sweat [HCO3-] (2.49 +/- 0.58 vs. 3.73 +/- 1.10 mEq L-1) and [lactate] (8.92 +/- 0.79 vs. 10.51 +/- 0.32 mmol L-1) tended to be greater after NaHCO3- ingestion, although significance was not reached (P=0.07 and P=0.08, respectively). These data indicate that induced metabolic alkalosis can modify sweat composition, although it is unclear whether the secretory coil, reabsorptive duct, or both are responsible for this alteration.

  20. Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data.

    Science.gov (United States)

    Accurso, Frank J; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J; Dong, Qunming; Ordonez, Claudia L; Rowe, Steven M; Clancy, John Paul; Konstan, Michael W; Hoch, Heather E; Heltshe, Sonya L; Ramsey, Bonnie W; Campbell, Preston W; Ashlock, Melissa A

    2014-03-01

    We examined data from a Phase 2 trial {NCT00457821} of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with aG551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing,and analysis was employed for the first time. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators.

  1. [Analysis of fatty acid composition of sweat lipids in children and adults with skin disease].

    Science.gov (United States)

    Andrashko, Iu V; Koliadenko, V G; Briuzgina, T S; Prokhorova, M P

    2002-01-01

    Gas-chromatographic analysis of fatty acid composition of sweat lipids in children and adults with neurodermatitis, atopic dermatitis, and eczema showed that sweat can be used as a new noninvasive biological object for evaluation of lipid metabolism disorders.

  2. Hot Soak

    OpenAIRE

    Goldwater, H.

    2005-01-01

    The DVD is documentation of Hot Soak, as performed at the Queen’s Hotel, Penzance, Cornwall in an en suite bathroom, for Tract: Live Art Festival, 2006, curated by Art Surgery/ Newlyn Art Gallery. Hot Soak was originally made for home, London, 2005. This piece marries an everyday environment (bathroom) with extraordinary materials (ice cubes/ dress bleeding red into water) creating the surreal. Sontag’s understanding of camp as a love of the unnatural, artifice and exaggeration, can be ci...

  3. Sweat sodium loss influences serum sodium concentration in a marathon.

    Science.gov (United States)

    Lara, B; Salinero, J J; Areces, F; Ruiz-Vicente, D; Gallo-Salazar, C; Abián-Vicén, J; Del Coso, J

    2017-02-01

    The aim of this investigation was to determine the influence of sweat electrolyte concentration on body water and electrolyte homeostasis during a marathon. Fifty-one runners completed a marathon race in a warm and dry environment (24.4 ± 3.6 °C). Runners were classified as low-salt sweaters (n = 21; sweat Na + concentration), typical sweaters (n = 20; ≥30 and sweat Na + concentration), and salty sweaters (n = 10; ≥60 mmol/L of sweat Na + concentration). Before and after the race, body mass and a sample of venous blood were obtained. During the race, sweat samples were collected by using sweat patches, and fluid and electrolyte intake were recorded by using self-reported questionnaires. Low-salt, typical and salty sweaters presented similar sweat rates (0.93 ± 0.2, 0.92 ± 0.29, 0.99 ± 0.21 L/h, respectively), body mass changes (-3.0 ± 1.0, -3.3 ± 1.0, -3.2 ± 0.8%), total Na + intake (12.7 ± 8.1, 11.5 ± 9.7, 14.5 ± 16.6 mmol), and fluid intake (1.3 ± 0.8, 1.2 ± 0.8, 1.2 ± 0.6 L) during the race. However, salty sweaters presented lower post-race serum Na + concentration (140.8 ± 1.3 vs 142.5 ± 1.1, 142.4 ± 1.4 mmol/L; P Sweat electrolyte concentration could influence post-race serum electrolyte concentration in the marathon. However, even the saltiest sweaters did not develop exercise-associated hyponatremia or associated symptoms. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Bullous lesions, sweat gland necrosis and rhabdomyolysis in alcoholic coma

    Directory of Open Access Journals (Sweden)

    Neelakandhan Asokan

    2014-01-01

    Full Text Available A 42-year-old male developed hemorrhagic bullae and erosions while in alcohol induced coma. The lesions were limited to areas of the body in prolonged contact with the ground in the comatose state. He developed rhabdomyolysis, progressing to acute renal failure (ARF. Histopathological examination of the skin showed spongiosis, intraepidermal vesicles, and necrosis of eccrine sweat glands with denudation of secretory epithelial lining cells. With supportive treatment and hemodialysis, the patient recovered in 3 weeks time. This is the first reported case of bullous lesions and sweat gland necrosis occurring in alcohol-induced coma complicated by rhabdomyolysis and ARF.

  5. Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis

    Science.gov (United States)

    Blackman, Scott M.; Raraigh, Karen S.; Corvol, Harriet; Rommens, Johanna M.; Pace, Rhonda G.; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R.; Strug, Lisa J.; Knowles, Michael R.; Cutting, Garry R.

    2016-01-01

    Rationale: Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. Objectives: To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. Methods: A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Measurements and Main Results: Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H2 = 0; 95% confidence interval, 0.0–0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Conclusions: Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker

  6. Wearable technologies for sweat rate and conductivity sensors

    CERN Document Server

    Salvo, Pietro

    2012-01-01

    Hauptbeschreibung Wearable sensors present a new frontier in the development of monitoring techniques. They are of great importance in sectors such as sports and healthcare, as they permit the continuous monitoring of physiological and biological elements, such as ECG and human sweat. Until recently, this could only be carried out in specialized laboratories in the presence of cumbersome, and usually, expensive devices. Sweat monitoring sensors integrated onto textile substrates are not only part of a new field of work but, they also represent the first attempt to implement such an

  7. Immediate Wheal Reactivity to Autologous Sweat in Atopic Dermatitis Is Associated with Clinical Severity, Serum Total and Specific IgE and Sweat Tryptase Activity.

    Science.gov (United States)

    Ilves, Tiina; Virolainen, Anu; Harvima, Ilkka Tapani

    2016-01-01

    Sweating can worsen atopic dermatitis (AD). The purpose of this work was to study the associations between reactivity to autologous sweat and the clinical severity of AD as well as investigate the possible wheal-inducing factors of sweat. Intracutaneous skin tests with autologous sweat were performed on 50 AD patients and 24 control subjects. In skin biopsies, tryptase and PAR-2 were enzyme and immunohistochemically stained. The associations between skin test reactivity and sweat histamine concentration, tryptase or chymase activity levels, tryptase or PAR-2 expression and AD clinical severity or IgE levels were investigated. The wheal reactions in the intracutaneous tests with autologous sweat were positive, weakly positive and negative in 38, 34 and 28% of the AD patients, respectively, and in 4, 46 and 50% of the healthy controls, respectively (p = 0.008). In AD, the wheal reaction was associated significantly with clinical severity, serum total and specific IgE levels and sweat tryptase activity, but not with sweat histamine and chymase. In nonlesional AD skin, the percentage of PAR-2+ mast cells (MCs) or the number of tryptase+ MCs did not differ significantly between the intracutaneous test reactivity groups. Reactivity to autologous sweat correlates with the clinical severity of AD, and tryptase may be one of the factors involved in the sweat-induced wheal. © 2016 S. Karger AG, Basel.

  8. Transient elevation of sweat chloride concentration in a malnourished girl with the Mauriac syndrome.

    Science.gov (United States)

    Polack, F P; Transue, D J; Belknap, W M; Freij, B J; Aughton, D J

    1995-02-01

    Elevated sweat chloride concentration in a patient with Mauriac syndrome has been reported only once. The authors of that report regarded their patient's underlying malnutrition, and not Mauriac syndrome per se, as the cause of the elevated sweat chloride concentration. We describe a second example of transient elevation of sweat chloride concentration, which confirms that the malnutrition intrinsic to Mauriac syndrome, rather than the syndrome itself, was the probable cause of elevated sweat chloride values.

  9. Simple barcode system based on ionogels for real time pH-sweat monitoring

    OpenAIRE

    Benito-Lopez, Fernando; Coyle, Shirley; Byrne, Robert; O’Toole, Corinne; Barry, Caroline; Diamond, Dermot

    2010-01-01

    This paper presents the fabrication, characterization and the performance of a wearable, robust, flexible and disposable barcode system based on novel ionic liquid polymer gels (ionogels) for monitoring in real time mode the pH of the sweat generated during an exercise period. Up to now sweat analysis has been carried out using awkward methods of collecting sweat followed by laboratory analysis. The approach presented here can provide immediate feedback regarding sweat composition. The great ...

  10. Hot flashes in breast cancer survivors and an association with calcium supplement use

    OpenAIRE

    Gretchen Kimmick; Gloria Broadwater; Mara Vitolins

    2010-01-01

    Gretchen Kimmick1,2, Gloria Broadwater2, Mara Vitolins31Medical Oncology, Wake Forest University School of Medicine, Winston-Salem; 2Cancer Center Biostatistics, Duke University Medical Center, Durham; 3Department of Epidemiology and Prevention, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USAAims: In breast cancer survivors, we aimed to describe the frequency of hot flashes and night sweats, frequency and type of treatment, and the association of hot flashes and ...

  11. Sweat lipid mediator profiling: a non-invasive approach for cutaneous research

    Science.gov (United States)

    Sweat is a complex biological fluid with potential diagnostic value for the investigation of skin disorders. Previous efforts in sweat testing focused on analysis of small molecules and ions for forensic and diagnostic testing, but with advances in analytical and sweat collection techniques, there h...

  12. Sweat it Out : Johannes de Gorter and Sudorifics in the Dutch Republic

    NARCIS (Netherlands)

    Verwaal, Ruben

    2017-01-01

    Today, many go for a run, cover themselves under blankets, or sit in the sauna believing that they can ‘sweat out’ the common cold. Whereas modern medicine has falsified the efficacy of sweating as treatment, this paper considers the development of medical research about sweating in the early modern

  13. Crying for a Vision: The Native American Sweat Lodge Ceremony as Therapeutic Intervention

    Science.gov (United States)

    Garrett, Michael Tlanusta; Torres-Rivera, Edil; Brubaker, Michael; Portman, Tarrell Awe Agahe; Brotherton, Dale; West-Olatunji, Cirecie; Conwill, William; Grayshield, Lisa

    2011-01-01

    The Native American sweat lodge ceremony or sweat therapy is being used increasingly in various medical, mental health, correctional, and substance abuse treatment centers serving both Native and non-Native clients. This article explores the sweat lodge ceremony's background, elements of Native American spirituality, origin story, cultural…

  14. Artificial sweat composition to grow and sustain a mixed human axillary microbiome.

    Science.gov (United States)

    Callewaert, Chris; Buysschaert, Benjamin; Vossen, Els; Fievez, Veerle; Van de Wiele, Tom; Boon, Nico

    2014-08-01

    A novel artificial sweat composition, Skin Community Interaction simulation, designed to mimic the human axillary sweat, was compared to other artificial sweat compositions. Axillary microbiota grown in the novel composition closely resembled the original community. Volatile organic compound analysis showed good correlations with in vivo axillary (mal)odor components. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Effects of stimulation technique, anatomical region and time on human sweat lipid mediator profiles.

    Science.gov (United States)

    Few studies compare sampling protocol effect on sweat composition. Here we evaluate the impact of sweat stimulation mode and site of collection on lipid mediator composition. Sweat from healthy males (n = 7) was collected weekly for three weeks from the volar forearm following either pilocarpine ion...

  16. Pituitary adenylate cyclase-activating polypeptide promotes eccrine gland sweat secretion

    DEFF Research Database (Denmark)

    Sasaki, S; Watanabe, J; Ohtaki, H

    2017-01-01

    BACKGROUND: Sweat secretion is the major function of eccrine sweat glands; when this process is disturbed (paridrosis), serious skin problems can arise. To elucidate the causes of paridrosis, an improved understanding of the regulation, mechanisms and factors underlying sweat production is requir...

  17. The Sweat Lodge Ceremony in Challenge/Adventure Programming.

    Science.gov (United States)

    Quinn, William J.; Smith, Thomas E.

    This paper advocates the potentials of "sweat lodge" rituals for adventure education programs. Historically, rituals and ceremonies have been instrumental in passing major philosophical and sociological paradigms from one generation to the next. However, there is little theory and research about how ritual and ceremony results in the…

  18. Do elephants need to sweat? | Wright | African Zoology

    African Journals Online (AJOL)

    An adequate rate of evaporative water loss is considered essential for the maintenance of thermal balance in the elephant in warm climatic conditions. Histological studies have failed to reveal the existence of sweat glands in elephant skin. Transepidermal water-loss rate has been measured and shown to be sufficiently ...

  19. the comfort, measured by means of a sweating manikin (waltertm)

    African Journals Online (AJOL)

    user

    Anton F Botha*, Marguerite E Stoffberg & Lawrance Hunter. ABSTRACT. With the growing importance of clothing comfort in South African and overseas markets for locally produced clothing, the Council for. Scientific Industrial Research (CSIR) acquired an advanced sweating fabric manikin for measuring clothing comfort.

  20. Sweating, thirst perception and plasma electrolyte composition in ...

    African Journals Online (AJOL)

    Thirst is a perception, the subjective experience evoked by fluid deficits. Exercise induces sweating and subsequently electrolyte loss and thirst but there is little documented on post exercise thirst perception in women of varying body mass indices. 40 apparently healthy young women (19-25years) in the follicular phase of ...

  1. Pituitary adenylate cyclase-activating polypeptide promotes eccrine gland sweat secretion.

    Science.gov (United States)

    Sasaki, S; Watanabe, J; Ohtaki, H; Matsumoto, M; Murai, N; Nakamachi, T; Hannibal, J; Fahrenkrug, J; Hashimoto, H; Watanabe, H; Sueki, H; Honda, K; Miyazaki, A; Shioda, S

    2017-02-01

    Sweat secretion is the major function of eccrine sweat glands; when this process is disturbed (paridrosis), serious skin problems can arise. To elucidate the causes of paridrosis, an improved understanding of the regulation, mechanisms and factors underlying sweat production is required. Pituitary adenylate cyclase-activating polypeptide (PACAP) exhibits pleiotropic functions that are mediated via its receptors [PACAP-specific receptor (PAC1R), vasoactive intestinal peptide (VIP) receptor type 1 (VPAC1R) and VPAC2R]. Although some studies have suggested a role for PACAP in the skin and several exocrine glands, the effects of PACAP on the process of eccrine sweat secretion have not been examined. To investigate the effect of PACAP on eccrine sweat secretion. Reverse transcriptase-polymerase chain reaction and immunostaining were used to determine the expression and localization of PACAP and its receptors in mouse and human eccrine sweat glands. We injected PACAP subcutaneously into the footpads of mice and used the starch-iodine test to visualize sweat-secreting glands. Immunostaining showed PACAP and PAC1R expression by secretory cells from mouse and human sweat glands. PACAP immunoreactivity was also localized in nerve fibres around eccrine sweat glands. PACAP significantly promoted sweat secretion at the injection site, and this could be blocked by the PAC1R-antagonist PACAP6-38. VIP, an agonist of VPAC1R and VPAC2R, failed to induce sweat secretion. This is the first report demonstrating that PACAP may play a crucial role in sweat secretion via its action on PAC1R located in eccrine sweat glands. The mechanisms underlying the role of PACAP in sweat secretion may provide new therapeutic options to combat sweating disorders. © 2016 British Association of Dermatologists.

  2. Exercise- and methylcholine-induced sweating responses in older and younger men: effect of heat acclimation and aerobic fitness

    Science.gov (United States)

    Inoue, Y.; Havenith, George; Kenney, W. Larry; Loomis, Joseph L.; Buskirk, Elsworth R.

    The purpose of this investigation was to examine the effects of aging and aerobic fitness on exercise- and methylcholine-induced sweating responses during heat acclimation. Five younger [Y group - age: 23+/-1 (SEM) years; maximal oxygen consumption (V.O2max): 47+/-3 ml.kg-1.min-1], four highly fit older (HO group - 63+/-3 years; 48+/-4 ml.kg-1.min-1) and five normally fit older men (NO group - 67+/-3 years; 30+/-1 ml.kg-1.min-1) who were matched for height, body mass and percentage fat, were heat acclimated by daily cycle exercise ( 35% V.O2max for 90 min) in a hot (43°C, 30% RH) environment for 8 days. The heat acclimation regimen increased performance time, lowered final rectal temperature (Tre) and percentage maximal heart rate (%HRmax), improved thermal comfort and decreased sweat sodium concentration similarly in all groups. Although total body sweating rates (M.sw) during acclimation were significantly greater in the Y and HO groups than in the NO group (Pgroup), the M.sw did not change in all groups with the acclimation sessions. Neither were local sweating rates (m.sw) on chest, back, forearm and thigh changed in all groups by the acclimation. The HO group presented greater forearm m.sw (30-90 min) values and the Y group had greater back and thigh m.sw (early in exercise) values, compared to the other groups (PHO>NO, and on the forearm Y=HO>NO. No group differences were observed for activated sweat gland density at any site. The SGO at the respective sites increased in the post-acclimation test regardless of group (Pgroups than in the Y group. These findings suggest that heat tolerance and the improvement with acclimation are little impaired not only in highly fit older but also normally fit older men, when the subjects exercised at the same relative exercise intensity. Furthermore, the changes induced by acclimation appear associated with an age-related decrease in V.O2max. However methylcholine-activated SGO and the magnitude of improvement of SGO with

  3. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    OpenAIRE

    Meyer,F.; Laitano,O.; Bar-Or,O.; McDougall,D.; Heigenhauser,G.J.F.

    2007-01-01

    The dependence of sweat composition and acidity on sweating rate (SR) suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac-) and ammonia (NH3) and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men) cycled in the heat (42ºC, 20% relative humidity) at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During b...

  4. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    OpenAIRE

    Meyer, Flavia; Lionello Neto, Orlando Laitano

    2007-01-01

    The dependence of sweat composition and acidity on sweating rate (SR) suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac-) and ammonia (NH3) and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men) cycled in the heat (42ºC, 20% relative humidity) at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject’s lower back. During b...

  5. Sweat output measurement of the post-ganglion sudomotor response by Q-Sweat Test: a normative database of Chinese individuals

    Directory of Open Access Journals (Sweden)

    Chen Shu-Fang

    2012-06-01

    Full Text Available Abstract Background Q-Sweat is a model used for evaluating the post-ganglionic sudomotor function by assessing sweat response. This study aimed to establish the normative database of Q-Sweat test among Chinese individuals since this type of information is currently lacking. Results One hundred and fifty (150 healthy volunteers, 76 men and 74 women with age range of 22–76 years were included. Skin temperature and sweat onset latency measured at the four sites (i.e., the forearm, proximal leg, distal leg, and the foot did not significantly correlate with age, gender, body height (BH, body weight (BW, and body mass index (BMI but the total sweat volume measured in all four sites significantly correlated with sex, BH, and BW. Except for the distal leg, the total sweat volume measured at the other three sites had a significant correlation with BMI. In terms of gender, men had larger total sweat volume, with median differences at the forearm, proximal leg, distal leg, and foot of 0.591 μl, 0.693 μl, 0.696 μl, and 0.358 μl, respectively. Regarding BW difference (≥62 and  Conclusion This is the first report to show the normative database of sweat response in Chinese participants evaluated using Q-Sweat device. This normative database can help guide further research on post-ganglionic sudomotor or related clinical practice involving a Chinese population.

  6. Plate tectonics

    Digital Repository Service at National Institute of Oceanography (India)

    Chaubey, A.K.

    Content-Type text/plain; charset=UTF-8 209 Plate Tectonics A. K. Chaubey National Institute of Oceanography, Dona Paula, Goa-403 004. chaubey@nio.org Introduction The theory of continental drift, which paved the way for discovery... of plate tectonics, was put forward by Alfred Lother Wegener - a meteorologist from Germany - in 1912. The theory states that continents are not fixed, but have been slowly wandering during the course of Earth’s geological history. Although Wegener...

  7. Hot spots

    National Research Council Canada - National Science Library

    Nia, Amir M; Gassanov, Natig; Er, Fikret

    2014-01-01

    ..., several reddened skin lesions were observed. The obvious ''hot spots'' were located on both sides in the groin and above the bladder, with extension to the genital region, compli- cating the ability to catheterize the patient (Figure 1). The rest of the body surface was not affected, and no infectious source for the skin lesions was evident. After suc...

  8. Hot flushes: are there effective alternatives to estrogen?

    Science.gov (United States)

    Sassarini, Jenifer; Lumsden, Mary Ann

    2010-06-01

    Hot flushes are the most common indication for the prescription of hormone replacement therapy (HRT) since it is effective in over 80% of cases. In 1995, 37% of American women took HRT, principally for this purpose. However, over the last five years, publications such as those from the Women's Health Initiative (WHI) have caused concern among women since they perceive that the risks outweigh the benefits. Following this publication, half of the women taking HRT in the UK, USA and New Zealand discontinued HRT. With the discontinuation of estrogen many women re-developed hot flushes; however only a small number (18%) of women report restarting hormone therapy. The majority of these (76%) for the recurrence of severe hot flushes or night sweats. Alternatives are available, but limited knowledge on aetiology and mechanisms of hot flushing represents a major obstacle for the development of new, targeted, non-hormonal treatments, and no current alternatives are as effective as estrogen.

  9. A novel organotypic 3D sweat gland model with physiological functionality.

    Directory of Open Access Journals (Sweden)

    Patricia Klaka

    Full Text Available Dysregulated human eccrine sweat glands can negatively impact the quality-of-life of people suffering from disorders like hyperhidrosis. Inability of sweating can even result in serious health effects in humans affected by anhidrosis. The underlying mechanisms must be elucidated and a reliable in vitro test system for drug screening must be developed. Here we describe a novel organotypic three-dimensional (3D sweat gland model made of primary human eccrine sweat gland cells. Initial experiments revealed that eccrine sweat gland cells in a two-dimensional (2D culture lose typical physiological markers. To resemble the in vivo situation as close as possible, we applied the hanging drop cultivation technology regaining most of the markers when cultured in its natural spherical environment. To compare the organotypic 3D sweat gland model versus human sweat glands in vivo, we compared markers relevant for the eccrine sweat gland using transcriptomic and proteomic analysis. Comparing the marker profile, a high in vitro-in vivo correlation was shown. Carcinoembryonic antigen-related cell adhesion molecule 5 (CEACAM5, muscarinic acetylcholine receptor M3 (CHRM3, Na+-K+-Cl- cotransporter 1 (NKCC1, calcium-activated chloride channel anoctamin-1 (ANO1/TMEM16A, and aquaporin-5 (AQP5 are found at significant expression levels in the 3D model. Moreover, cholinergic stimulation with acetylcholine or pilocarpine leads to calcium influx monitored in a calcium flux assay. Cholinergic stimulation cannot be achieved with the sweat gland cell line NCL-SG3 used as a sweat gland model system. Our results show clear benefits of the organotypic 3D sweat gland model versus 2D cultures in terms of the expression of essential eccrine sweat gland key regulators and in the physiological response to stimulation. Taken together, this novel organotypic 3D sweat gland model shows a good in vitro-in vivo correlation and is an appropriate alternative for screening of potential

  10. Sweat output measurement of the post-ganglion sudomotor response by Q-Sweat Test: a normative database of Chinese individuals

    Science.gov (United States)

    2012-01-01

    Background Q-Sweat is a model used for evaluating the post-ganglionic sudomotor function by assessing sweat response. This study aimed to establish the normative database of Q-Sweat test among Chinese individuals since this type of information is currently lacking. Results One hundred and fifty (150) healthy volunteers, 76 men and 74 women with age range of 22–76 years were included. Skin temperature and sweat onset latency measured at the four sites (i.e., the forearm, proximal leg, distal leg, and the foot) did not significantly correlate with age, gender, body height (BH), body weight (BW), and body mass index (BMI) but the total sweat volume measured in all four sites significantly correlated with sex, BH, and BW. Except for the distal leg, the total sweat volume measured at the other three sites had a significant correlation with BMI. In terms of gender, men had larger total sweat volume, with median differences at the forearm, proximal leg, distal leg, and foot of 0.591 μl, 0.693 μl, 0.696 μl, and 0.358 μl, respectively. Regarding BW difference (≥62 and sweat volume. Median differences at the forearm, proximal leg, distal leg, and foot were 0.538 μl, 0.744 μl, 0.695 μl, and 0.338 μl, respectively. There was an uneven distribution of male and female participants in the two BW groups. In all conditions, the total sweat volume recorded at the foot site was the smallest. Conclusion This is the first report to show the normative database of sweat response in Chinese participants evaluated using Q-Sweat device. This normative database can help guide further research on post-ganglionic sudomotor or related clinical practice involving a Chinese population. PMID:22682097

  11. Endoscopic lumbar sympathectomy for women: effect on compensatory sweat

    Directory of Open Access Journals (Sweden)

    Marcelo de Paula Loureiro

    2008-01-01

    Full Text Available INTRODUCTION: Plantar hyperhidrosis is present in 50% of patients with hyperhidrosis. Thoracic sympathectomy is an important tool for the treatment of this condition, which is successful in about 60% of patients. For the remaining patients, lumbar sympathectomy is the procedure of choice. As new minimally invasive techniques have been developed, a significant demand for this type of access has led to its adaptation to the lumbar sympathectomy. The objective of this study was to evaluate the effectiveness of endoscopic retroperitoneal lumbar sympathectomy in controlling plantar hyperhidrosis and its effects on compensatory sweat. MATERIALS AND METHODS: Thirty female patients with persistent plantar hyperhidrosis after thoracic sympathectomy were enrolled. They were randomly assigned to laparoscopic retroperitoneal lumbar sympathectomy (Group A or no surgical intervention (Group B - control groups. Quality-of-life modifications were assessed by specific questionnaires before and after surgery. In the same manner, direct sweat measurements were also performed pre- and post-intervention by evaluating trans-epidermal water loss. Despite the lack of intervention, the control group was evaluated at similar timepoints. RESULTS: In Group A, no major complications occurred in the peri-operative period. During the immediate post-operative period, three patients (20% experienced prolonged pain (more than ten days. Eight patients suffered from worsened compensatory sweating (53.3%. In Group A, after lumbar sympathectomy, the quality of life significantly improved (p<0.05, intra-group comparison beyond that of the control group (p<0.05, inter-group comparison. Also, lumbar sympathectomy resulted in significantly lower values of foot sweat (pre- vs. post-operative periods, p<0.05; Group A vs. Group B, p<0.05. These patients also developed higher values of sweat measurements on specific points of their dorsal and abdominal regions after the procedure (p<0

  12. Thermoregulation, Fluid Balance, and Sweat Losses in American Football Players.

    Science.gov (United States)

    Davis, Jon K; Baker, Lindsay B; Barnes, Kelly; Ungaro, Corey; Stofan, John

    2016-10-01

    Numerous studies have reported on the thermoregulation and hydration challenges athletes face in team and individual sports during exercise in the heat. Comparatively less research, however, has been conducted on the American Football player. Therefore, the purpose of this article is to review data collected in laboratory and field studies and discuss the thermoregulation, fluid balance, and sweat losses of American Football players. American Football presents a unique challenge to thermoregulation compared with other sports because of the encapsulating nature of the required protective equipment, large body size of players, and preseason practice occurring during the hottest time of year. Epidemiological studies report disproportionately higher rates of exertional heat illness and heat stroke in American Football compared with other sports. Specifically, larger players (e.g., linemen) are at increased risk for heat ailments compared with smaller players (e.g., backs) because of greater body mass index, increased body fat, lower surface area to body mass ratio, lower aerobic capacity, and the stationary nature of the position, which can reduce heat dissipation. A consistent finding across studies is that larger players exhibit higher sweating rates than smaller players. Mean sweating rates from 1.0 to 2.9 L/h have been reported for college and professional American Football players, with several studies reporting 3.0 L/h or more in some larger players. Sweat sodium concentration of American Football players does not seem to differ from that of athletes in other sports; however, given the high volume of sweat loss, the potential for sodium loss is higher in American Football than in other sports. Despite high sweating rates with American Football players, the observed disturbances in fluid balance have generally been mild (mean body mass loss ≤2 %). The majority of field-based studies have been conducted in the northeastern part of the United States, with limited

  13. Sweating responses to isometric hand-grip exercise and forearm muscle metaboreflex in prepubertal children and elderly.

    Science.gov (United States)

    Amano, Tatsuro; Kai, Seiko; Nakajima, Michi; Ichinose-Kuwahara, Tomoko; Gerrett, Nicola; Kondo, Narihiko; Inoue, Yoshimitsu

    2017-02-01

    What is the central question of this study? Non-thermal factors (e.g. muscle metaboreflex) contribute to the sweating response during exercise. Although it is well recognized that the sweating responses caused by core temperature elevation in prepubertal children and the elderly are attenuated compared with young adults, it is unknown whether non-thermal sweating is also attenuated in these populations. What is the main finding and its importance? The non-thermal sweating response during isometric hand-grip exercise and isolated muscle metaboreflex were attenuated in prepubertal children compared with young adults in a non-uniform manner over the body, but only during the muscle metaboreflex in the elderly. This may explain the maturation- and ageing-related decline of sweating during exercise. The purpose of the present study was to investigate sweating responses to isometric hand-grip (IH) exercise and muscle metaboreflex in prepubertal children and the elderly. In hot conditions (ambient temperature, 35°C; relative humidity, 45%), 13 healthy young adults, 10 prepubertal children and 10 elderly subjects (aged 20.4 ± 1.2, 11.4 ± 0.5 and 63.5 ± 3.1 years, respectively) repeated a three hand-grip exercise protocol that consisted of 1 min IH exercise at 15, 30 or 45% of maximal voluntary contraction (MVC) followed by 2 min postexercise forearm occlusion. Local sweat rates (SRs) on the forehead, chest, forearm, thigh and palm were continuously measured (ventilated capsule method). The forehead SR in prepubertal children during IH exercise at 45% MVC was significantly lower than that of young adults (0.26 ± 0.22 and 0.08 ± 0.15 mg cm-2  min-1 for young adults and children, respectively; P elderly at any exercise intensities. The SR on the chest (0.22 ± 0.22 and -0.01 ± 0.05 mg cm-2  min-1 for young adults and children, respectively), forearm (0.14 ± 0.12 and 0.03 ± 0.04 mg cm-2  min-1 ) and thigh (0.13 ± 0.10 and 0.02 ± 0

  14. HOT 2017

    DEFF Research Database (Denmark)

    Hannibal, Sara Stefansen

    HOT er en kvalitativ undersøgelse, der hvert år diskuterer og undersøger en lille udvalgt skare af danskkyndige fagpersoners bud på, hvad de er optagede af på literacyområdet her og nu – altså hvilke emner, de vil vurdere som aktuelle at forholde sig til i deres nuværende praksis....

  15. Body Odor Trait Disgust Sensitivity Predicts Perception of Sweat Biosamples.

    Science.gov (United States)

    Liuzza, Marco Tullio; Olofsson, Jonas K; Sabiniewicz, Agnieszka; Sorokowska, Agnieszka

    2017-07-01

    Body odors are potent triggers of disgust and regulate social behaviors in many species. The role of olfaction in disgust-associated behaviors has received scant attention in the research literature, in part because olfactory disgust assessments have required laboratory testing with odors. We have devised the "Body Odor Disgust Scale" (BODS) to facilitate research on olfactory disgust. In this study, we evaluated whether individual differences in BODS scores would be associated with the perception of disgust for sweat samples in a laboratory setting. Results show that BODS was a strong predictor of disgust ratings of sweat samples even when controlling for general disgust sensitivity. In contrast, odor intensity ratings were unrelated to BODS scores. Our findings suggest that the BODS scores reflect body odor disgust perception. The BODS scale might facilitate research on olfactory disgust responses and associated behaviors. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. 3D modeling and characterization of a calorimetric flow rate sensor for sweat rate sensing applications

    Science.gov (United States)

    Iftekhar, Ahmed Tashfin; Ho, Jenny Che-Ting; Mellinger, Axel; Kaya, Tolga

    2017-03-01

    Sweat-based physiological monitoring has been intensively explored in the last decade with the hopes of developing real-time hydration monitoring devices. Although the content of sweat (electrolytes, lactate, urea, etc.) provides significant information about the physiology, it is also very important to know the rate of sweat at the time of sweat content measurements because the sweat rate is known to alter the concentrations of sweat compounds. We developed a calorimetric based flow rate sensor using PolydimethylSiloxane that is suitable for sweat rate applications. Our simple approach on using temperature-based flow rate detection can easily be adapted to multiple sweat collection and analysis devices. Moreover, we have developed a 3D finite element analysis model of the device using COMSOL Multiphysics™ and verified the flow rate measurements. The experiment investigated flow rate values from 0.3 μl/min up to 2.1 ml/min, which covers the human sweat rate range (0.5 μl/min-10 μl/min). The 3D model simulations and analytical model calculations covered an even wider range in order to understand the main physical mechanisms of the device. With a verified 3D model, different environmental heat conditions could be further studied to shed light on the physiology of the sweat rate.

  17. Laboratory performance of sweat conductivity for the screening of cystic fibrosis.

    Science.gov (United States)

    Greaves, Ronda F; Jolly, Lisa; Massie, John; Scott, Sue; Wiley, Veronica C; Metz, Michael P; Mackay, Richard J

    2017-10-09

    There are several complementary English-language guidelines for the performance of the sweat chloride test. These guidelines also incorporate information for the collection of conductivity samples. However, recommendations for the measurement and reporting of sweat conductivity are less clear than for sweat chloride. The aim of the study was to develop an understanding of the testing and reporting practices of sweat conductivity in Australasian laboratories. A survey specifically directed at conductivity testing was sent to the 12 laboratories registered with the Royal College of Pathologists of Australasia Quality Assurance Programs. Nine (75%) laboratories participated in the survey, seven of whom used Wescor Macroduct® for collecting sweat and the Wescor SWEAT·CHEK™ for conductivity testing, and the remaining two used the Wescor Nanoduct®. There was considerable variation in frequency and staffing for this test. Likewise, criteria about which patients it was inappropriate to test, definitions of adequate collection sweat rate, cutoffs and actions recommended on the basis of the result showed variations between laboratories. Variations in sweat conductivity testing and reporting reflect many of the same issues that were revealed in sweat chloride test audits and have the potential to lead to uncertainty about the result and the proper action in response to the result. We recommend that sweat testing guidelines should include clearer statements about the use of sweat conductivity.

  18. Topics in histopathology of sweat gland and sebaceous neoplasms.

    Science.gov (United States)

    Ansai, Shin-Ichi

    2017-03-01

    This article reviews several topics regarding sweat gland and sebaceous neoplasms. First, the clinicopathological characteristics of poroid neoplasms are summarized. It was recently reported that one-fourth of poroid neoplasms are composite tumors and one-fourth are apocrine type lesions. Recent progress in the immunohistochemical diagnosis of sweat gland neoplasms is also reviewed. CD117 can help to distinguish sweat gland or sebaceous tumors from other non-Merkel cell epithelial tumors of the skin. For immunohistochemical differential diagnosis between sweat gland carcinoma (SGC) other than primary cutanesous apocrine carcinoma and skin metastasis of breast carcinoma (SMBC), a panel of antibodies may be useful, including p63 (SGC+ , SMBC- ), CK5/6 (SGC+ , SMBC- ), podoplanin (SGC+ , SMBC- ) and mammaglobin (SGC- , SMBC+ ). Comparison of antibodies used for immunohistochemical diagnosis of sebaceous carcinoma (SC) suggests that adipophilin has the highest sensitivity and specificity. Some authors have found that immunostaining for survivin, androgen receptor and ZEB2/SIP1 has prognostic value for ocular SC, but not extraocular SC. In situ SC is rare, especially extraocular SC, but there have been several recent reports that actinic keratosis and Bowen's disease are the source of invasive SC. Finally, based on recent reports, classification of sebaceous neoplasms into three categories is proposed, which are sebaceoma (a benign neoplasm with well-defined architecture and no atypia), borderline sebaceous neoplasm (low-grade SC; an intermediate tumor with well-defined architecture and nuclear atypia) and SC (a malignant tumor with invasive growth and evident nuclear atypia). © 2017 Japanese Dermatological Association.

  19. Concentration of electrolytes in the sweat of malnourished children.

    OpenAIRE

    Rodrigues, M. E.; M. C. MELO; Reis, F J; Penna, F J

    1994-01-01

    The sweat test was performed by the method of Gibson and Cooke on 36 children with second and third degree malnutrition, aged from 2 months to 4 years. The results were compared with those from 32 healthy, well nourished controls in the same age range. Determinations were made of sodium and chloride concentrations, chloride/sodium ratio, and the sum of the concentrations of the two electrolytes in each sample. The malnourished children were found to have higher sodium and chloride concentrati...

  20. Coloured sweat in two brothers: First report of familial chromhidrosis.

    Science.gov (United States)

    Gaffney, Daniel C; Cooper, Hywel L

    2016-02-01

    The uncommon diagnosis of chromhidrosis is most frequently made in young adults. This sweat gland disease, although benign, may impact significantly on the patient's quality of life. We describe the first report of familial chromhidrosis of pseudo-eccrine type (pseudochromhidrosis) occurring in two brothers aged 9 and 12 years. The classification and causality of chromhidrosis is described and approaches to assessment and management are outlined. © 2015 The Australasian College of Dermatologists.

  1. The English 'sweate' (Sudor Anglicus) and Hantavirus pulmonary syndrome.

    Science.gov (United States)

    Bridson, E

    2001-01-01

    A rapidly fatal viral infectious disease appeared in England in 1485, persisted for the summer months and disappeared as winter approached. This pattern of infection re-appeared in 1508, 1517, 1528, and finally 1551. The epidemic never returned. It had no respect for wealth or rank, and predominantly attacked males between the ages of 15 and 45 years. The incubation period was frighteningly short and the outcome normally fatal. The symptoms of acute respiratory disease and copious sweating were characteristic, providing the name 'the English sweating disease'. It was never in the big league of killer epidemics, such as plague and influenza, but its pockets of instant lethality in communities gave it a special ranking of horror. The infective cause of this disease remained a total mystery until it was compared with Hantavirus pulmonary syndrome (HPS) in 1994. The strength of this theory is examined in this paper, and it is concluded that, although there is a close resemblance, HPS does not match the English sweating disease completely and positive identification of a possible rodent carrier for the latter was not established.

  2. Anthropometric profile and sweat rate in young soccer players

    Directory of Open Access Journals (Sweden)

    Luciana Rossi

    2009-04-01

    Full Text Available Soccer is a sport whose worldwide acceptance has been growing year after year, and is one of the most important events in the sports world. A growing number of children and teenagers are engaged in this activity, but studies regarding risk factors such as adiposity and negative impacts such as dehydration and hyperthermia are scarce. The aim of this study was to evaluate the anthropometric profile, sweat rate and risk of dehydration among young soccer players. For anthropometric assessment, weight, height, circumference measures and skinfold thickness were collected and used for the determination of body mass index and percent body fat of each player. For determination of the sweat rate, players were weighed before and after pre-competition training. Analysis of fat percentage (14.4 ± 3.6% and the sum of skinfolds showed that the players presented an optimal percentage and activity pattern, probably related to their role in the game. Although low (8.8 ± 6.6 mL/min, the sweat rate varied widely among players, wit the observation of a significant reduction (p<0.05 in final weight. The risk of dehydration was low, but the same cannot be stated for the risk of hyperthermia. Further studies involving this population are necessary to establish an adequate hydration strategy, with emphasis on the monitoring of signs of hyperthermia.

  3. Anthropometric profile and sweat rate in young soccer players

    Directory of Open Access Journals (Sweden)

    Vanessa Aparecida de Brito Reis

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n2p134   Soccer is a sport whose worldwide acceptance has been growing year after year, and is one of the most important events in the sports world. A growing number of children and teenagers are engaged in this activity, but studies regarding risk factors such as adiposity and negative impacts such as dehydration and hyperthermia are scarce. The aim of this study was to evaluate the anthropometric profile, sweat rate and risk of dehydration among young soccer players. For anthropometric assessment, weight, height, circumference measures and skinfold thickness were collected and used for the determination of body mass index and percent body fat of each player. For determination of the sweat rate, players were weighed before and after pre-competition training. Analysis of fat percentage (14.4 ± 3.6% and the sum of skinfolds showed that the players presented an optimal percentage and activity pattern, probably related to their role in the game. Although low (8.8 ± 6.6 mL/min, the sweat rate varied widely among players, wit the observation of a significant reduction (p < 0.05 in final weight. The risk of dehydration was low, but the same cannot be stated for the risk of hyperthermia. Further studies involving this population are necessary to establish an adequate hydration strategy, with emphasis on the monitoring of signs of hyperthermia.

  4. Metastatic apocrine sweat gland adenocarcinoma in a terrier dog.

    Science.gov (United States)

    Baharak, Akhtardanesh; Reza, Kheirandish; Shahriar, Dabiri; Omid, Azari; Daruoosh, Vosoogh; Nasrin, Askari

    2012-08-01

    This report describes the clinical and pathological aspects of an apocrine sweat gland carcinoma with distant metastasis in an aged dog. A 7-year-old male terrier dog was referred to small animal hospital of Shahid Bahonar University of Kerman with a 5.5×3.5 centimeter pedunculated mass on its head near left auricular region which had been progressively growing since three months ago. The radiography showed no local and distant metastasis. Surgical excision and histological evaluation was done. Histologically, the mass was composed of epithelial cells arranged in glandular and solid patterns. The morphologic findings suggested either a primary or metastatic apocrine-gland carcinoma. Immunohistochemically, the tumor cells were intensely positive for cytokeratin 7 and 20 and negative for S100 protein. On the basis of histopathological and clinical findings, the tumor was diagnosed as a malignant apocrine gland tumor, arising from apocrine sweat glands of the skin. Local tumor recurrence with anorexia and weight loss was reported by the owner nine month later. Severe submandibular and prescapular lymphadenomegaly was noted in clinical examination. Several large pulmonary nodules were noted in chest radiographs resembling mediastinal lymph node metastasis. Second surgery and chemotherapy was rejected by the owner due to grave prognosis of the patient. The animal was died 45 days later due to respiratory complications. Tumors of apocrine sweat glands are relatively uncommon in dogs whereas apocrine gland adenocarcinoma with distant metastasis is extremely rare.

  5. The Mechanical Strength of Acrylic Palatal Plates Reinforced with Net or Bundle Glass Fibers

    OpenAIRE

    Hedzelek, W.; Gajdus, P.; Joniak, S.

    2002-01-01

    The aim of the study was to evaluate the resistant forces of acrylic palatal plates reinforced with glass net and unidirectional glass fibers. The form and models of the edentulous jaw (Frasaco) were used in the study. Palatal plates were made from hot polymerised acrylic SR Triplex Hot (Ivoclar). In the total reinforced method the studied palatal plates used were reinforced with one or three layers of fiber glass net (Stick Net). In the partial reinforced method acrylic palatal plates wer...

  6. On sweat analysis for quantitative estimation of dehydration during physical exercise.

    Science.gov (United States)

    Ring, Matthias; Lohmueller, Clemens; Rauh, Manfred; Eskofier, Bjoern M

    2015-08-01

    Quantitative estimation of water loss during physical exercise is of importance because dehydration can impair both muscular strength and aerobic endurance. A physiological indicator for deficit of total body water (TBW) might be the concentration of electrolytes in sweat. It has been shown that concentrations differ after physical exercise depending on whether water loss was replaced by fluid intake or not. However, to the best of our knowledge, this fact has not been examined for its potential to quantitatively estimate TBW loss. Therefore, we conducted a study in which sweat samples were collected continuously during two hours of physical exercise without fluid intake. A statistical analysis of these sweat samples revealed significant correlations between chloride concentration in sweat and TBW loss (r = 0.41, p sweat osmolality and TBW loss (r = 0.43, p sweat samples.

  7. Bounds on geologically current rates of motion of groups of hot spots

    Science.gov (United States)

    Wang, Chengzu; Gordon, Richard G.; Zhang, Tuo

    2017-06-01

    It is widely believed that groups of hot spots in different regions of the world are in relative motion at rates of 10 to 30 mm a-1 or more. Here we present a new method for analyzing geologically current motion between groups of hot spots beneath different plates. In an inversion of 56 globally distributed, equally weighted trends of hot spot tracks, the dispersion is dominated by differences in trend between different plates rather than differences within plates. Nonetheless the rate of hot spot motion perpendicular to the direction of absolute plate motion, vperp, differs significantly from zero for only 3 of 10 plates and then by merely 0.3 to 1.4 mm a-1. The global mean upper bound on |vperp| is 3.2 ± 2.7 mm a-1. Therefore, hot spots move slowly and can be used to define a global reference frame for plate motions.

  8. Imaging calcium carbonate distribution in human sweat pore in vivo using nonlinear microscopy

    Science.gov (United States)

    Chen, Xueqin; Gasecka, Alicja; Formanek, Florian; Galey, Jean-Baptiste; Rigneault, Hervé

    2015-03-01

    Nonlinear microscopies, including two-photon excited autofluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS), were used to study individual human sweat pore morphology and topically applied antiperspirant salt penetration inside sweat pore, in vivo on human palms. Sweat pore inner morphology in vivo was imaged up to the depth of 100 μm by TPEF microscopy. The 3D penetration and distribution of "in situ calcium carbonate" (isCC), an antiperspirant salt model, was investigated using CARS microscopy.

  9. The effect of heat acclimation on sweat microminerals: artifact of surface contamination.

    Science.gov (United States)

    Ely, Matthew R; Kenefick, Robert W; Cheuvront, Samuel N; Chinevere, Troy; Lacher, Craig P; Lukaski, Henry C; Montain, Scott J

    2013-10-01

    Heat acclimation (HA) reportedly conveys conservation in sweat micromineral concentrations when sampled from arm sweat, but time course is unknown. The observation that comprehensive cleaning of the skin surface negates sweat micromineral reductions during prolonged sweating raises the question of whether the reported HA effect is real or artifact of surface contamination. To measure sweat mineral concentrations serially during HA and determine if surface contamination plays a role in the reported mineral reductions. Calcium (Ca), copper (Cu), magnesium (Mg), and zinc (Zn) were measured in sweat obtained from 17 male volunteers using an arm bag on Day 1, 5, and 10 of a HA protocol. To study the role of contamination, sweat was simultaneously (n = 10 subjects) sampled twice daily from a cleaned site (WASH) and unclean site (NO WASH) on the scapular surface. Sweat Ca, Cu, and Mg from Arm Bag trended progressively downward from Day 1 to Day 10 of HA (p = .10-0.25). Micromineral concentrations from the WASH site did not change between Day 1, 5, or 10 (Ca = 0.30 ± 0.12 mmol/L, Cu 0.41 ± 0.53 μmol/L; Zn 1.11 ± 0.80 μmol/L). Surface contamination can confound sweat mineral estimates, as sweat Ca and Cu from NO WASH site were initially higher than WASH (p Heat acclimation does not confer reductions in sweat Ca, Cu, Mg, or Zn. When the skin surface is not cleaned, mineral residue inflates initial sweat mineral concentrations. Earlier reports of micromineral reductions during HA may have been confounded by interday cleaning variability.

  10. Multidimensional Raman spectroscopic signature of sweat and its potential application to forensic body fluid identification.

    Science.gov (United States)

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-03-09

    This proof-of-concept study demonstrated the potential of Raman microspectroscopy for nondestructive identification of traces of sweat for forensic purposes. Advanced statistical analysis of Raman spectra revealed that dry sweat was intrinsically heterogeneous, and its biochemical composition varies significantly with the donor. As a result, no single Raman spectrum could adequately represent sweat traces. Instead, a multidimensional spectroscopic signature of sweat was built that allowed for the presentation of any single experimental spectrum as a linear combination of two fluorescent backgrounds and three Raman spectral components dominated by the contribution from lactate, lactic acid, urea and single amino acids. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Characterization of sweat induced with pilocarpine, physical exercise, and collected passively by metabolomic analysis.

    Science.gov (United States)

    Souza, S L; Graça, G; Oliva, A

    2017-11-12

    The elimination of the pain associated with needle picking is a strong motivation for the development of clinical non-invasive diagnostic methods. Sweat has been described as an alternative biological sample that may have a direct relation to the plasma composition. In this study, analysis of sweat of human volunteers obtained by induction with pilocarpine is compared with sweat samples obtained by physical exercise and by passive collection along 7 hours. The sweat samples have been analyzed by 1H nuclear magnetic resonance spectroscopy. A range of 34 different metabolites has been detected in sweat samples, including lactate, several amino acids, pyroglutamate, and urocanate. Most of the metabolites identified were quantified. The majority of the amino acids detected in sweat seem to have origin in the epidermis surface. No significant differences in sweat samples from female and male were observed by 1H NMR metabolomic analysis. Principal component analysis (PCA) shows that both physical exercise and pilocarpine methods seem to be equally reproducible methods in terms of sweat metabolite composition presenting better repeatability than natural sweat collection. Nevertheless, this difference is mainly originated from amino acids with origin from the skin surface. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Composition of sweat of the horse during prolonged epinephrine (adrenaline) infusion, heat exposure, and exercise.

    Science.gov (United States)

    Kerr, M G; Snow, D H

    1983-08-01

    Temporal changes in sweat composition were studied in 4 horses during epinephrine (adrenaline) infusion (0.13 to 0.31 micrograms/kg/min for 3 hours), heat exposure (41 C, [33 C wet bulb] for 5 to 6 hours), and exercise (16 to 18 km/hr for 58 to 80 km). Four ponies also were studied during heat exposure. Sweat produced by each of the stimuli was hypertonic for Na+, K+, and Cl-. These electrolyte concentrations remained constant during the central period of the experiments, with changes occurring near the beginning and toward the end. The Na+ was significantly higher and K+ significantly lower in epinephrine-induced sweat than in heat-induced sweat, and the pattern of change in sweat Na/K ratio varied among the 3 stimuli. The Ca2+ concentration decreased with time and was hypotonic after 15 minutes of epinephrine-induced sweating. Concentrations of Mg2+ and protein decreased exponentially with time. There was a high correlation between them, although the Mg2+ was not protein-bound. Sweat urea concentration was directly related to plasma urea concentration. When plasma glucose concentration became greater than 10 to 12 mmole/L during epinephrine infusion, glucose appeared in the sweat and its concentration rose to 8 to 12 mmole/L of sweat when plasma glucose was more than 20 mmole/L.

  13. In vivo sweat film layer thickness measured with Fourier-domain optical coherence tomography

    CSIR Research Space (South Africa)

    Jonathan, E

    2008-01-01

    Full Text Available the added advantage of supporting near-real time or video rate imaging speed. Consequently, FD-OCT supports assessment of tissue structure as well as near-real time imaging of functioning small organs in tissue [16–19]. The focus of this paper is direct... accurate measurement of SFL thickness as a diagnostic parameter of sweat intensity while near-real time imaging of the responsible small organs, namely sweat glands, sweat ducts and sweat pores is also of interest. 2. Experimental 2.1. Apparatus OCT...

  14. Low abundance of sweat duct Cl− channel CFTR in both healthy and cystic fibrosis athletes with exceptionally salty sweat during exercise

    Science.gov (United States)

    Haack, Karla K. V.; Pollack, Brian P.; Millard-Stafford, Mindy; McCarty, Nael A.

    2011-01-01

    To understand potential mechanisms explaining interindividual variability observed in human sweat sodium concentration ([Na+]), we investigated the relationship among [Na+] of thermoregulatory sweat, plasma membrane expression of Na+ and Cl− transport proteins in biopsied human eccrine sweat ducts, and basal levels of vasopressin (AVP) and aldosterone. Lower ductal luminal membrane expression of the Cl− channel cystic fibrosis transmembrane conductance regulator (CFTR) was observed in immunofluorescent staining of sweat glands from healthy young adults identified as exceptionally “salty sweaters” (SS) (n = 6, P sweat [Na+] (control, n = 6). Genetic testing of healthy subjects did not reveal any heterozygotes (“carriers”) for any of the 39 most common disease-causing CFTR mutations in the United States. SS had higher baseline plasma [AVP] compared with control (P = 0.029). Immunostaining to investigate a potential relationship between higher plasma [AVP] (and sweat [Na+]) and ductal membrane aquaporin-5 revealed for all groups a relatively sparse and location-dependent ductal expression of the water channel with localization primarily to the secretory coil. Availability of CFTR for NaCl transport across the ductal membrane appears related to the significant physiological variability observed in sweat salt concentration in apparently healthy humans. At present, a heritable link between healthy salty sweaters and the most prevalent disease-causing CFTR mutations cannot be established. PMID:21228336

  15. Sweat control in male by the use of alunogen and cypripedium pubescens

    Directory of Open Access Journals (Sweden)

    Lorenzo Martini

    2015-01-01

    Full Text Available Aim of my study is to investigate upon the quality and quantity of the free fatty acids secreted by apocrine glands, as chief index to determine the real efficacy of a new model of antiperspirant-deodorant, that interferes directly with apocrine glands (by reducing drastically the secretion of free fatty acids and indirectly with eccrine glands, by minimising the salted water secretion. I created an innovative cosmetic formula that comprises the Alunogen, idest the heptadecahydrated form of aluminium sulphate, since the generic aluminium sulphate has been recently accused of the onset of the Alzheimer’s disease, when penetrating the epidermis, although definitive scientific proof is difficult to establish due to the lack of longitudinal studies, and therefore could be banished in the very next future. The formula comprises also the concrète of Cypripedium Pubescens (Lady’s slipper which contains, inter alia, the cypripedin, a quinine-analog, endowed by anticholinergic activities, that can be reputed useful as astringent agent with regards to eccrine glands, synergically to the action upon apocrine glands performed by alunogen. I recruited 11 young men, 11 bricklayers that customarily have to work 9 hours pro day after the hot summer sun and assert without doubt to sweat copiously, in order to carry out my experience.

  16. A wearable multisensing patch for continuous sweat monitoring.

    Science.gov (United States)

    Anastasova, Salzitsa; Crewther, Blair; Bembnowicz, Pawel; Curto, Vincenzo; Ip, Henry Md; Rosa, Bruno; Yang, Guang-Zhong

    2017-07-15

    In sport, exercise and healthcare settings, there is a need for continuous, non-invasive monitoring of biomarkers to assess human performance, health and wellbeing. Here we report the development of a flexible microfluidic platform with fully integrated sensing for on-body testing of human sweat. The system can simultaneously and selectively measure metabolite (e.g. lactate) and electrolytes (e.g. pH, sodium) together with temperature sensing for internal calibration. The construction of the platform is designed such that continuous flow of sweat can pass through an array of flexible microneedle type of sensors (50µm diameter) incorporated in a microfluidic channel. Potentiometric sodium ion sensors were developed using a polyvinyl chloride (PVC) functional membrane deposited on an electrochemically deposited internal layer of Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer. The pH sensing layer is based on a highly sensitive membrane of iridium oxide (IrOx). The amperometric-based lactate sensor consists of doped enzymes deposited on top of a semipermeable copolymer membrane and outer polyurethane layers. Real-time data were collected from human subjects during cycle ergometry and treadmill running. A detailed comparison of sodium, lactate and cortisol from saliva is reported, demonstrating the potential of the multi-sensing platform for tracking these outcomes. In summary, a fully integrated sensor for continuous, simultaneous and selective measurement of sweat metabolites, electrolytes and temperature was achieved using a flexible microfluidic platform. This system can also transmit information wirelessly for ease of collection and storage, with the potential for real-time data analytics. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Towards Addressing the Body Electrolyte Environment via Sweat Analysis:Pilocarpine Iontophoresis Supports Assessment of Plasma Potassium Concentration.

    Science.gov (United States)

    Vairo, Donato; Bruzzese, Laurie; Marlinge, Marion; Fuster, Lea; Adjriou, Nabil; Kipson, Nathalie; Brunet, Philippe; Cautela, Jennifer; Jammes, Yves; Mottola, Giovanna; Burtey, Stephane; Ruf, Jean; Guieu, Regis; Fenouillet, Emmanuel

    2017-09-18

    Electrolyte concentration in sweat depends on environmental context and physical condition but also on the pathophysiological status. Sweat analyzers may be therefore the future way for biological survey although how sweat electrolyte composition can reflect plasma composition remains unclear. We recruited 10 healthy subjects and 6 patients to have a broad range of plasma electrolyte concentrations (chloride, potassium and sodium) and pH. These variables were compared to those found in sweat produced following cycling exercise or pilocarpine iontophoresis, a condition compatible with operating a wearable device. We found no correlation between plasma and sweat parameters when exercise-induced sweat was analyzed, and we could identify a correlation only between plasma and sweat potassium concentration (R = 0.78, p sweat was induced using pilocarpine iontophoresis. We tested measurement repeatability in sweat at 24hr-interval for 3 days in 4 subjects and found a great intra-individual variability regarding all parameters in exercise-induced sweat whereas similar electrolyte levels were measured in pilocarpine-induced sweat. Thus, electrolyte concentration in sweat sampled following physical activity does not reflect concentration in plasma while pilocarpine iontophoresis appears to be promising to reproducibly address sweat electrolytes, and to make an indirect evaluation of plasma potassium concentration in chronic kidney disease and arrhythmia.

  18. Create Your Plate

    Medline Plus

    Full Text Available ... A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective ... and that your options are endless. Create Your Plate! Click on the plate sections below to add ...

  19. Sweat patterns differ between tilt-induced reflex syncope and tilt-induced anxiety among youth.

    Science.gov (United States)

    Heyer, Geoffrey L; Harvey, Rebecca A; Islam, Monica P

    2016-08-01

    Profound sweating can occur with reflex-syncope and with emotional distress, but little is known about the similarities and differences between these sweat responses when they occur during orthostatic challenge. We sought to characterize and compare the sweat patterns related to tilt-induced syncope, presyncope, anxiety, and normal tilt testing. In a prospective observational study, quantitative sweat rate was measured from the abdomen, forearm, ankle, and thigh during head-upright tilt. Sweat characteristics were compared across tilt diagnoses of syncope, presyncope, anxiety, and normal testing. When anxiety and syncope/presyncope occurred during the same study (separated by ≥6 min), both were diagnosed. Our cohort comprised150 patients (15.1 ± 2.3 years; 82.9 % female) with 156 diagnoses: 76 with reflex-syncope, 31 with presyncope, 23 with anxiety, and 26 with normal results. All syncope/presyncope patients and 20 (87 %) of the anxiety patients had corresponding sweat responses. Minimal or negligible sweating occurred among patients with normal tests. Neither basal sweat (19.4 ± 4.7 versus 18.3 ± 3.7 versus 18.5 ± 3.7 nL/min/cm(2)) nor peak sweat (171 ± 47.4 versus 149.4 ± 64.4 versus 154.4 ± 59.2 nL/min/cm(2)) differed between patients with syncope, presyncope, or anxiety, p = .32 and p = .12, respectively. However, the qualitative sweat patterns related to syncope/presyncope (diffuse, smoothly contoured, symmetrical, single peaks) differed considerably from the sweat patterns related to anxiety (heterogeneous, asymmetrical, roughly contoured single-peak, multi-peak, or progressive sweat changes). The sweat patterns related to syncope/presyncope are distinguishable from the sweat patterns related to anxiety. Recognition of the different sweat patterns can inform how signs and symptoms are interpreted during clinical orthostatic challenge.

  20. Fungal protein MGL_1304 in sweat is an allergen for atopic dermatitis patients.

    Science.gov (United States)

    Hiragun, Takaaki; Ishii, Kaori; Hiragun, Makiko; Suzuki, Hidenori; Kan, Takanobu; Mihara, Shoji; Yanase, Yuhki; Bartels, Joachim; Schröder, Jens-M; Hide, Michihiro

    2013-09-01

    Sweat is a major aggravating factor of atopic dermatitis (AD) and approximately 80% of patients with AD show type I hypersensitivity against sweat. To identify and characterize an antigen in sweat that induces histamine release from basophils of patients with AD. Basophil histamine-releasing activity in sweat was purified by a combination of chromatographies, and proteins were analyzed with mass spectrometry. Recombinant proteins of the sweat antigen were generated, and their biological characteristics were studied by immunoblots, histamine release tests, and neutralization assays. We identified a fungal protein, MGL_1304, derived from Malassezia globosa (M globosa) in the purified sweat antigen. Recombinant MGL_1304 induced histamine release from basophils of most of the patients with AD, in accordance with the semi-purified sweat antigen. Moreover, recombinant MGL_1304 abolished the binding of serum IgE of patients with AD to the semi-purified sweat antigen, or vice versa in immunoblot analysis, and attenuated the sensitization of RBL-48 mast cells expressing human FcɛRI by serum IgE. Studies of truncated mutants of MGL_1304 indicated that IgE of patients with AD recognized the conformational structure of MGL_1304 rather than short peptide sequences. Western blot analysis of the whole lysate, the culture supernatant of M globosa, and the semi-purified sweat antigen showed that MGL_1304 was produced as a minor immunological antigen of M globosa with posttranslational modification, cleaved, and secreted as a 17-kDa major histamine-releasing sweat antigen. MGL_1304 is a major allergen in human sweat and could cause type I allergy in patients with AD. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  1. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    Science.gov (United States)

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  2. Volume and composition of hand sweat of White and Black men and women in desert walks.

    Science.gov (United States)

    Dill, D B; Yousef, M K; Goldman, A; Hillyard, S D; Davis, T P

    1983-05-01

    Many investigators have sought, but failed to find, ethnic differences in the number and regional distribution of active sweat glands. In this study measurements have been made of sweat secreted on one hand and also on the whole body of Whites and Blacks walking in desert heat. Whites numbered 31 men and 27 women, ages 30 to 88 years; there were 21 Black men and 31 Black women, ages 16 to 61 years. Each walked on three occasions for 1 hour at a rate that required an oxygen consumption of about 40% of aerobic capacity. Ambient temperature ranged from 32 to 44 degrees C in 1979 and 1980; means were 38.4 degrees C in 1979 and 36.7 degrees C in 1980. There was no sweat in the gloves of many Blacks; this was true of only a few Whites. Volume of body sweat increased in both races with rate of walking; volume of hand sweat increased more in Whites than in Blacks. The Mann-Whitney test revealed that volumes of hand sweat were significantly greater for Whites than for Blacks. It was concluded that in desert walks most Whites and few Blacks sweat freely on their hands. In samples of hand sweat, Na+, K+, and Cl- were determined. Concentrations of each ion varied widely in both races, and were unrelated to race. Concentrations of Na+ and Cl- generally are somewhat higher in hand sweat than in body sweat; concentrations of K+ are much higher. It follows that the values for concentration of Na+ and Cl- reported in Table 3 probably are somewhat higher than would have been found in body sweat, and concentrations of K+ are probably much higher.

  3. Comparison of three methods for estimation of exercise-related ion losses in sweat of horses.

    Science.gov (United States)

    Kingston, J K; McCutcheon, L J; Geor, R J

    1999-10-01

    To quantify total fluid loss in sweat of Thoroughbreds during >3 hours of low-intensity exercise in controlled conditions and to calculate and compare estimated ion losses in sweat, according to 3 methods. 6 exercise-trained Thoroughbreds. Fluid and ion losses in sweat were measured in 6 horses exercising at 40% of the speed that elicited maximum oxygen consumption for 45 km. Horses were given a 15-minute rest period at the end of three 15-km exercise phases. Horses completed 2 exercise trials. Ion losses in sweat were calculated, using measurements of local sweating rate and sweat ion composition (SWT), change in net exchangeable cation content (CAT), and change in extracellular ion content (PLAS) derived from plasma total solids and ion concentrations. Measurement of SWT revealed a mean (+/- SEM) fluid loss in sweat during 45 km of exercise of 27.5 +/- 1.6 L. Total ion loss in sweat was approximately 241 g or 7.8 mol with higher sodium losses in the second and third phases of exercise compared with the first phase. Losses of sodium and potassium calculated by SWT or CAT were not significantly different from each other, whereas losses of these ions as determined by PLAS were significantly lower. Calculation of ion losses from a mean whole body sweating rate extrapolated from either local sweating rate and sweat ion composition or from change in net exchangeable cation content provide similar results, whereas ion losses determined by changes in extracellular ion content derived from plasma total solids and ion concentration results in underestimation of actual losses.

  4. Metastatic apocrine sweat gland adenocarcinoma in a terrier dog

    OpenAIRE

    Baharak, Akhtardanesh; Reza, Kheirandish; Shahriar, Dabiri; Omid, Azari; Daruoosh, Vosoogh; Nasrin, Askari

    2012-01-01

    This report describes the clinical and pathological aspects of an apocrine sweat gland carcinoma with distant metastasis in an aged dog. A 7-year-old male terrier dog was referred to small animal hospital of Shahid Bahonar University of Kerman with a 5.5×3.5 centimeter pedunculated mass on its head near left auricular region which had been progressively growing since three months ago. The radiography showed no local and distant metastasis. Surgical excision and histological evaluation was don...

  5. Sex differences in amino acids lost via sweating could lead to differential susceptibilities to disturbances in nitrogen balance and collagen turnover

    OpenAIRE

    Dunstan, R. H.; Sparkes, D. L.; Dascombe, B. J.; Stevens, C. J.; Murphy, G. R.; Macdonald, M. M.; Gottfries, J.; Gottfries, C.-G.; Roberts, T. K.

    2017-01-01

    Fluid collected during sweating is enriched with amino acids derived from the skin?s natural moisturising factors and has been termed ?faux? sweat. Little is known about sex differences in sweat amino acid composition or whether faux sweat amino acid losses affect nitrogen balance. Faux sweat collected by healthy adults (n?=?47) after exercise, and at rest by chronic fatigue patients, was analysed for amino acid composition. Healthy females had higher total amino acid concentrations in sweat ...

  6. Comparison of Quantitative Sweat Chloride Methods after Positive Newborn Screen for Cystic Fibrosis

    Science.gov (United States)

    Laguna, Theresa A.; Lin, Nan; Wang, Qi; Holme, Bonnie; McNamara, John; Regelmann, Warren E.

    2013-01-01

    Summary Objectives Rapid and reliable confirmatory sweat testing following a positive newborn screen (NBS) for cystic fibrosis (CF) is preferred to allow for early diagnosis and to decrease parental anxiety. The Cystic Fibrosis Foundation (CFF) recently recommended a quantity not sufficient (QNS) rate of ≤ 10% in infants sweat chloride analysis. Two CFF-approved methods are available by which to quantitatively measure chloride concentration in sweat. Our objective was to compare the performance of the Macroduct® sweat collection system (MSCS) with the Gibson and Cooke technique (GCT) in the acquisition of samples for the determination of sweat chloride concentration in infants with a positive Minnesota State NBS for cystic fibrosis. Methods A retrospective database review of infants referred to the core Minnesota CF Center or its affiliate site for confirmatory sweat testing was performed to compare the QNS rates for the two techniques. Associations between birthweight, age at test, race and QNS rates were examined. Results 568 infants were referred for 616 sweat tests from March 2006–January 2010. The mean age was 32.8 days at the initial sweat test. The GCT had a significantly higher QNS rate compared to the MSCS (15.4% vs. 2.1%, psweat testing in infants following a positive state NBS. PMID:22786625

  7. Sweat : Materiality and Fluidity of Perspiration in in Eighteenth-Century Medicine

    NARCIS (Netherlands)

    Verwaal, Ruben

    2015-01-01

    How can a bodily excretion like sweat, often accompanied with a stench or associated with anxiety and distress, enrich our view of the history of science? This paper argues that following the fluid and flow of sweat has in fact particular advantages, because it provides a unique perspective by

  8. Lactate and ammonia concentration in blood and sweat during incremental cycle ergometer exercise

    NARCIS (Netherlands)

    Ament, W; Huizenga, [No Value; Mook, GA; Gips, CH; Verkerke, GJ

    It is known that the concentrations of ammonia and lactate in blood increase during incremental exercise. Sweat also contains lactate and ammonia. The aim of the present study was to investigate the physiological response of lactate and ammonia in plasma and sweat during a stepwise incremental cycle

  9. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications

    Science.gov (United States)

    Sonner, Z.; Wilder, E.; Heikenfeld, J.; Kasting, G.; Beyette, F.; Swaile, D.; Sherman, F.; Joyce, J.; Hagen, J.; Kelley-Loughnane, N.; Naik, R.

    2015-01-01

    Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat. PMID:26045728

  10. Relationship between sweat chloride, sodium, and age in clinically obtained samples.

    Science.gov (United States)

    Traeger, Nadav; Shi, Qiuhu; Dozor, Allen J

    2014-01-01

    The relationship between sweat electrolytes and age is uncertain, as is the value of measuring sodium or the chloride:sodium ratio. 13,785 sweat tests performed over 23 years at one center through the Macroduct collection in clinically obtained samples were analyzed. Sweat chloride tended to decrease over the first year of life, slowly increase until the fourth decade, then either level off or slightly decrease. In children, sweat sodium overlapped between those with positive and negative sweat tests, but not in adults. If the sweat test was positive, there was a higher likelihood of having a chloride:sodium ratio >1, but most subjects with a ratio >1 did not have CF. Sweat chloride and sodium vary with age. Measurement of sweat sodium did not add discriminatory value. The proportion of subjects with a chloride:sodium ratio >1, with or without CF, varied greatly between age ranges. © 2013. Published by Elsevier B.V. on behalf of European Cystic Fibrosis Society. All rights reserved.

  11. The detection of cortisol in human sweat: implications for measurement of cortisol in hair.

    Science.gov (United States)

    Russell, Evan; Koren, Gideon; Rieder, Michael; Van Uum, Stan H M

    2014-02-01

    Hair cortisol analysis has been shown to be an effective measure of chronic stress. Cortisol is assumed to incorporate into hair via serum, sebum, and sweat sources; however, the extent to which sweat contributes to hair cortisol content is unknown. Sweat and saliva samples were collected from 17 subjects after a period of intensive exercise and analyzed by salivary enzyme-linked immunosorbent assay (ELISA). Subsequently, an in vitro test on exposure of hair to hydrocortisone was conducted. Residual hair samples were immersed in a 50-ng/mL hydrocortisone solution for periods lasting 15 minutes to 24 hours, followed by a wash or no-wash condition. Hair cortisol content was determined using our modified protocol for a salivary ELISA. Postexercise control sweat cortisol concentrations ranged from 8.16 to 141.7 ng/mL and correlated significantly with the log-transformed time of day. Sweat cortisol levels significantly correlated with salivary cortisol concentrations. In vitro hair exposure to a 50-ng/mL hydrocortisone solution (mimicking sweat) for 60 minutes or more resulted in significantly increased hair cortisol concentrations. Washing with isopropanol did not affect immersion-increased hair cortisol concentrations. Human sweat contains cortisol in concentrations comparable with salivary cortisol levels. This study suggests that perfuse sweating after intense exercise may increase cortisol concentrations detected in hair. This increase likely cannot be effectively decreased with conventional washing procedures and should be considered carefully in studies using hair cortisol as a biomarker of chronic stress.

  12. A Simple and Valid Method to Determine Thermoregulatory Sweating Threshold and Sensitivity

    Science.gov (United States)

    2009-01-01

    therefore, preferred for sweating threshold temperature and sensitivity analysis (32). Volunteers spit into a cup during data collection to avoid spurious...MA, Stephenson LA. Control of sweating during the human menstrual cycle. Eur J Appl Physiol 58: 890–895, 1989. 21. Kondo N, Shibasaki M, Aoki K, Koga

  13. Biological Variation of Chloride and Sodium in Sweat Obtained by Pilocarpine Iontophoresis in Adults: How Sure are You About Sweat Test Results?

    Science.gov (United States)

    Willems, Philippe; Weekx, Steven; Meskal, Anissa; Schouwers, Sofie

    2017-04-01

    The measurement of chloride and sodium concentrations in sweat is an important test for the diagnosis of cystic fibrosis (CF). The aim of this study was to assess the analytical variation (CV A ) and within-subject (CV I ) and between-subject (CV G ) biological variation of chloride and sodium concentrations in sweat, collected by pilocarpine iontophoresis and to determine their effect on the clinical interpretation of sweat test results. Twelve Caucasian adults (six male and six female) without symptoms suggestive for CF and with a mean age of 41 years (range 28-59) were included in the study. At least eight samples of sweat were collected from each individual by pilocarpine iontophoresis. Chloride and sodium concentrations were measured in duplicate for each sample using ion selective electrodes. After the removal of outliers, the CV A , CV I , and CV G of chloride and sodium were determined, and their impact on measurement uncertainty and reference change value were calculated. The CV A , CV I , and CV G of chloride in sweat samples were 6.5, 17.7, and 47.2%, respectively. The CV A , CV I , and CV G of sodium sweat samples were 6.0, 17.5, and 42.6%, respectively. Our study indicates that sweat chloride and sodium concentration results must be interpreted with great care. Different components of variation, particularly the biological variations, have a considerable impact on the interpretation of these results. If no pre-analytical, analytical, or post-analytical errors are suspected, repeated sweat testing to confirm first-measurement results might not be desirable.

  14. Immunological multimetal deposition for rapid visualization of sweat fingerprints.

    Science.gov (United States)

    He, Yayun; Xu, Linru; Zhu, Yu; Wei, Qianhui; Zhang, Meiqin; Su, Bin

    2014-11-10

    A simple method termed immunological multimetal deposition (iMMD) was developed for rapid visualization of sweat fingerprints with bare eyes, by combining the conventional MMD with the immunoassay technique. In this approach, antibody-conjugated gold nanoparticles (AuNPs) were used to specifically interact with the corresponding antigens in the fingerprint residue. The AuNPs serve as the nucleation sites for autometallographic deposition of silver particles from the silver staining solution, generating a dark ridge pattern for visual detection. Using fingerprints inked with human immunoglobulin G (hIgG), we obtained the optimal formulation of iMMD, which was then successfully applied to visualize sweat fingerprints through the detection of two secreted polypeptides, epidermal growth factor and lysozyme. In comparison with the conventional MMD, iMMD is faster and can provide additional information than just identification. Moreover, iMMD is facile and does not need expensive instruments. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Corrosion behavior of nickel-containing alloys in artificial sweat.

    Science.gov (United States)

    Randin, J P

    1988-07-01

    The corrosion resistance of various nickel-containing alloys was measured in artificial sweat (perspiration) using the Tafel extrapolation method. It was found that Ni, CuNi 25 (coin alloy), NiAl (colored intermetallic compounds), WC + Ni (hard metal), white gold (jewelry alloy), FN42 and Nilo Alby K (controlled expansion alloys), and NiP (electroless nickel coating) are in an active state and dissolve readily in oxygenated artificial sweat. By contrast, austenitic stainless steels, TiC + Mo2C + Ni (hard metal), NiTi (shape-memory alloy), Hastelloy X (superalloy), Phydur (precipitation hardening alloy), PdNi and SnNi (nickel-containing coatings) are in a passive state but may pit under certain conditions. Cobalt, Cr, Ti, and some of their alloys were also investigated for the purpose of comparison. Cobalt and its alloys have poor corrosion resistance except for Stellite 20. Chromium and high-chromium ferritic stainless steels have a high pitting potential but the latter are susceptible to crevice corrosion. Ti has a pitting potential greater than 3 V. Comparison between the in vitro measurements of the corrosion rate of nickel-based alloys and the clinical observation of the occurrence of contact dermatitis is discussed.

  16. Proteomic and peptidomic analysis of human sweat with emphasis on proteolysis.

    Science.gov (United States)

    Yu, Yijing; Prassas, Ioannis; Muytjens, Carla M J; Diamandis, Eleftherios P

    2017-02-23

    Sweat is produced by eccrine and apocrine glands and represents a biological fluid with established roles in thermo-regulation and host infection defense. The composition of sweat is highly dynamic and alters significantly in various skin and other disorders. Therefore, in-depth profiling of sweat protein composition is expected to augment our understanding of the pathobiology of several skin diseases and may lead to the identification of useful sweat-based disease biomarkers. We here reported an in-depth analysis of the human sweat proteome and peptidome. Sweat was collected from healthy males and healthy females of ages 20-60years, following strenuous exercise. Two sweat pools were prepared (1 for males and 1 for females) and were subjected to sample preparation for mass spectrometric analysis. We identified a total of 861 unique proteins during our proteomic analysis and 32,818 endogenous peptides (corresponding to additional 1067 proteins) from our peptidomics workflow. As expected, the human skin was identified as the most abundant source of sweat proteins and peptides. Several skin proteases and protease inhibitors were identified in human sweat, highlighting the intense proteolytic activity of human skin. The presence of several antimicrobial peptides supports the functional roles of sweat in host defense and innate immunity. Sweat is a skin-associated biological fluid, secreted by eccrine and apocrine glands, with essential function in body thermo-regulation and host infection defense. In the present study, we performed in-depth profiling of both sweat proteome and peptidome composition. Our data provide the most in-depth characterization of the skin's catalytic network present in sweat. For the first time, we brought to light novel peptides in human sweat that potentially have antimicrobial activity, which highlight the important role of this fluid in innate immunity. All these findings allow us to have a better understanding of the complex web of

  17. Towards Addressing the Body Electrolyte Environment via Sweat Analysis:Pilocarpine Iontophoresis Supports Assessment of Plasma Potassium Concentration

    OpenAIRE

    Vairo, Donato; Bruzzese, Laurie; Marlinge, Marion; Fuster, Lea; Adjriou, Nabil; Kipson, Nathalie; Brunet, Philippe; Cautela, Jennifer; Jammes, Yves; Mottola, Giovanna; Burtey, Stephane; Ruf, Jean; Guieu, Regis; Fenouillet, Emmanuel

    2017-01-01

    Electrolyte concentration in sweat depends on environmental context and physical condition but also on the pathophysiological status. Sweat analyzers may be therefore the future way for biological survey although how sweat electrolyte composition can reflect plasma composition remains unclear. We recruited 10 healthy subjects and 6 patients to have a broad range of plasma electrolyte concentrations (chloride, potassium and sodium) and pH. These variables were compared to those found in sweat ...

  18. Brain blood flow and cardiovascular responses to hot flashes in postmenopausal women.

    Science.gov (United States)

    Lucas, Rebekah A I; Ganio, Matthew S; Pearson, James; Crandall, Craig G

    2013-03-01

    This study tested two related hypotheses: (1) brain blood flow is reduced during postmenopausal hot flashes, and (2) the magnitude of this reduction in brain blood flow is greater during hot flashes when blood pressure is reduced. Eleven healthy, normotensive postmenopausal women rested in a temperature-controlled laboratory (∼ 25°C) for approximately 120 minutes while waiting for a hot flash to occur. The onset of a hot flash was objectively identified by an abrupt increase in sternal sweat rate (capacitance hygrometry). Middle cerebral artery blood velocity (MCAv; transcranial Doppler) and mean arterial pressure (Finometer) were measured continuously. Each hot flash was divided into eight equal segments, and the segment with the largest reduction in MCAv and mean arterial pressure was identified for each hot flash. During experimental sessions, 25 hot flashes occurred (lasting a mean [SD] of 6.2 [2.8] min, with a mean frequency of 3 [1] hot flashes per participant). Seventy-six percent of hot flashes were accompanied by a clear reduction (>5%) in brain blood flow. For all hot flashes, the mean maximal decrease in MCAv was 12% (9%) (7 [6] cm s). This value did not correlate with corresponding changes in mean arterial pressure (R = 0.36). These findings demonstrate that hot flashes are often accompanied by clear reductions in brain blood flow that do not correspond with short-term reductions in mean arterial blood pressure.

  19. Alternatives to hormone therapy for hot flashes: many choices but science is lacking.

    Science.gov (United States)

    Richardson, Marcie K

    2013-09-01

    A 51-year-old postmenopausal third-grade teacher requests help for her hot flashes. She finds them especially troubling as she stands in front of her class and starts sweating. Although one student offers her tissues, others make fun of her--disrupting the class. Her sleep is interrupted several times a night. She refuses to use any form of estrogen because her mother died of breast cancer at the age of 60 years. Perhaps alternative therapies can help her.

  20. Sweat-inducing physiological challenges do not result in acute changes in hair cortisol concentrations.

    Science.gov (United States)

    Grass, Juliane; Kirschbaum, Clemens; Miller, Robert; Gao, Wei; Steudte-Schmiedgen, Susann; Stalder, Tobias

    2015-03-01

    Hair cortisol concentrations (HCC) are assumed to provide a stable, integrative marker of long-term systemic cortisol secretion. However, contrary to this assumption, some recent observations have raised the possibility that HCC may be subject to acute influences, potentially related to cortisol incorporation from sweat. Here, we provide a first detailed in vivo investigation of this possibility comprising two independent experimental studies: study I (N=42) used a treadmill challenge to induce sweating together with systemic cortisol reactivity while in study II (N=52) a sauna bathing challenge induced sweating without systemic cortisol changes. In both studies, repeated assessments of HCC, salivary cortisol, cortisol in sweat and individuals' sweating rate (single assessment) were conducted on the experimental day and at a next-day follow-up. Results across the two studies consistently revealed that HCC were not altered by the acute interventions. Further, HCC were found to be unrelated to acute salivary cortisol reactivity, sweat cortisol levels, sweating rate or the time of examination. In line with previous data, cortisol levels in sweat were strongly related to total salivary cortisol output across the examined periods. The present results oppose recent case report data by showing that single sweat-inducing interventions do not result in acute changes in HCC. Our data also tentatively speak against the notion that cortisol in sweat may be a dominant source of HCC. Further, our findings also indicate that HCC are not subject to diurnal variation. This research provides further support for hair cortisol analysis as a marker of integrated long-term systemic cortisol secretion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Attitudes about Advances in Sweat Patch Testing in Drug Courts: Insights from a Case Study in Southern California

    Science.gov (United States)

    Polzer, Katherine

    2010-01-01

    Drug courts are reinventing the drug testing framework by experimenting with new methods, including use of the sweat patch. The sweat patch is a band-aid like strip used to monitor drug court participants. The validity and reliability of the sweat patch as an effective testing method was examined, as well as the effectiveness, meaning how likely…

  2. Responses of distance runners and sprinters to exercise in a hot environment.

    Science.gov (United States)

    Irion, G L

    1987-10-01

    The responses of highly trained distance runners and track sprinters and age-matched untrained men were compared during bicycle ergometry in a 40 degree temperature-controlled environmental chamber. There were no differences among groups in rectal temperature following the 90 min exercise bout. Distance runners had a lower heart rate than either sprinters or untrained subjects. There was no difference in heart rate between sprinters and untrained subjects. Distance runners and sprinters had a much greater sweat rate than untrained subjects and dissipated a greater proportion of their total heat load by evaporation of sweat. Sprinters, however, had a lower sweat rate than distance runners in the hot environment and could only maintain as low a skin temperature as distance runners for 75 min of the 90 min session. Both aerobic training and anaerobic training confer some degree of protection from heat injury during exercise in a hot environment. However, sprinters have a higher heart rate and cannot sustain a low skin temperature as long as distance runners. Sprinters lost their advantage over untrained subjects in skin temperature after 75 min of exercise in a hot environment and did not have a lower heart rate than untrained subjects. Distance runners had a significantly lower heart rate and maintained a lower skin temperature than untrained subjects for the entire 90 min exercise bout.

  3. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat.

    Science.gov (United States)

    Meyer, F; Laitano, O; Bar-Or, O; McDougall, D; Heigenhauser, G J F; Heingenhauser, G J F

    2007-01-01

    The dependence of sweat composition and acidity on sweating rate (SR) suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac-) and ammonia (NH3) and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men) cycled in the heat (42 degrees C, 20% relative humidity) at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During bout 1, sweat from girls and boys had higher Lac- concentrations (23.6 +/- 1.2 and 21.2 +/- 1.7 mM; P sweat from women and men (18.2 +/- 1.9 and 14.8 +/- 1.6 mM, respectively), but Lac- was weakly associated with SR (P > 0.05; r = -0.27). Sweat Lac- concentration dropped during exercise bout 2, reaching similar levels among all groups (overall mean = 13.7 +/- 0.4 mM). Children had a higher sweat NH3 than adults during bout 1 (girls = 4.2 +/- 0.4, boys = 4.6 +/- 0.6, women = 2.7 +/- 0.2, and men = 3.0 +/- 0.2 mM; P sweat pH was lower than that of adults (mean +/- SEM, girls = 5.4 +/- 0.2, boys = 5.0 +/- 0.1, women = 6.2 +/- 0.5, and men = 6.2 +/- 0.4 for bout 1, and girls = 5.4 +/- 0.2, boys = 6.5 +/- 0.5, women = 5.2 +/- 0.2, and men = 6.9 +/- 0.4 for bout 2). This may have favored NH3 transport from plasma to sweat as accounted for by a significant correlation between sweat NH3 and H+ (r = 0.56). Blood pH increased from rest (mean +/- SEM; 7.3 +/- 0.02) to the end of exercise (7.4 +/- 0.01) without differences among groups. These results, however, are representative of sweat induced by moderate exercise in the absence of acidosis.

  4. Eccrine Sweat Contains IL-1α, IL-1β and IL-31 and Activates Epidermal Keratinocytes as a Danger Signal

    Science.gov (United States)

    Dai, Xiuju; Okazaki, Hidenori; Hanakawa, Yasushi; Murakami, Masamoto; Tohyama, Mikiko; Shirakata, Yuji; Sayama, Koji

    2013-01-01

    Eccrine sweat is secreted onto the skin's surface and is not harmful to normal skin, but can exacerbate eczematous lesions in atopic dermatitis. Although eccrine sweat contains a number of minerals, proteins, and proteolytic enzymes, how it causes skin inflammation is not clear. We hypothesized that it stimulates keratinocytes directly, as a danger signal. Eccrine sweat was collected from the arms of healthy volunteers after exercise, and levels of proinflammatory cytokines in the sweat were quantified by ELISA. We detected the presence of IL-1α, IL-1β, and high levels of IL-31 in sweat samples. To investigate whether sweat activates keratinocytes, normal human keratinocytes were stimulated with concentrated sweat. Western blot analysis demonstrated the activation of NF-κB, ERK, and JNK signaling in sweat-stimulated keratinocytes. Real-time PCR using total RNA and ELISA analysis of supernatants showed the upregulation of IL-8 and IL-1β by sweat. Furthermore, pretreatment with IL-1R antagonist blocked sweat-stimulated cytokine production and signal activation, indicating that bioactive IL-1 is a major factor in the activation of keratinocytes by sweat. Moreover, IL-31 seems to be another sweat stimulator that activates keratinocytes to produce inflammatory cytokine, CCL2. Sweat is secreted onto the skin's surface and does not come into contact with keratinocytes in normal skin. However, in skin with a defective cutaneous barrier, such as atopic dermatitis-affected skin, sweat cytokines can directly act on epidermal keratinocytes, resulting in their activation. In conclusion, eccrine sweat contains proinflammatory cytokines, IL-1 and IL-31, and activates epidermal keratinocytes as a danger signal. PMID:23874436

  5. Eccrine sweat contains IL-1α, IL-1β and IL-31 and activates epidermal keratinocytes as a danger signal.

    Directory of Open Access Journals (Sweden)

    Xiuju Dai

    Full Text Available Eccrine sweat is secreted onto the skin's surface and is not harmful to normal skin, but can exacerbate eczematous lesions in atopic dermatitis. Although eccrine sweat contains a number of minerals, proteins, and proteolytic enzymes, how it causes skin inflammation is not clear. We hypothesized that it stimulates keratinocytes directly, as a danger signal. Eccrine sweat was collected from the arms of healthy volunteers after exercise, and levels of proinflammatory cytokines in the sweat were quantified by ELISA. We detected the presence of IL-1α, IL-1β, and high levels of IL-31 in sweat samples. To investigate whether sweat activates keratinocytes, normal human keratinocytes were stimulated with concentrated sweat. Western blot analysis demonstrated the activation of NF-κB, ERK, and JNK signaling in sweat-stimulated keratinocytes. Real-time PCR using total RNA and ELISA analysis of supernatants showed the upregulation of IL-8 and IL-1β by sweat. Furthermore, pretreatment with IL-1R antagonist blocked sweat-stimulated cytokine production and signal activation, indicating that bioactive IL-1 is a major factor in the activation of keratinocytes by sweat. Moreover, IL-31 seems to be another sweat stimulator that activates keratinocytes to produce inflammatory cytokine, CCL2. Sweat is secreted onto the skin's surface and does not come into contact with keratinocytes in normal skin. However, in skin with a defective cutaneous barrier, such as atopic dermatitis-affected skin, sweat cytokines can directly act on epidermal keratinocytes, resulting in their activation. In conclusion, eccrine sweat contains proinflammatory cytokines, IL-1 and IL-31, and activates epidermal keratinocytes as a danger signal.

  6. Sweat gland tumor (Eccrine Porocarcinoma of scalp: A rare tumor

    Directory of Open Access Journals (Sweden)

    Rana Roshani

    2005-01-01

    Full Text Available Eccrine Porocarcinoma is a rare neoplasm arising from sweat glands. It was first described by Pinkus and Mehregan as ′Epidermotropic eccrine carcinoma′. It may occur de novo or as a malignant transformation of an eccrine poroma. It is commonly found in older age group and in the lower extremities. Clinically, it may present as a verrucous plaque, polypoid growth or an ulcerative lesion of long duration. Local recurrence and metastasis to skin, lymphnodes, viscera, and bone may occur. Treatment is wide local excision. Metastatic lesions can be treated with chemotherapy. We report a case of eccrine porocarcinoma of the scalp in a 50 years old female who presented to us with a bosselated, firm, painless, non-tender, freely mobile swelling over left fronto-parietal region of 12 years duration. It was excised and histopathological diagnosis was Eccrine Porocarcinoma. In literature, scalp porocarcinoma is a very rare tumor.

  7. Sweat: a sample with limited present applications and promising future in metabolomics.

    Science.gov (United States)

    Mena-Bravo, A; Luque de Castro, M D

    2014-03-01

    Sweat is a biofluid with present scant use as clinical sample. This review tries to demonstrate the advantages of sweat over other biofluids such as blood or urine for routine clinical analyses and the potential when related to metabolomics. With this aim, critical discussion of sweat samplers and equipment for analysis of target compounds in this sample is made. Well established routine analyses in sweat as is that to diagnose cystic fibrosis, and the advantages and disadvantages of sweat versus urine or blood for doping control have also been discussed. Methods for analytes such as essential metals and xenometals, ethanol and electrolytes in sweat in fact constitute target metabolomics approaches or belong to any metabolomics subdiscipline such as metallomics, ionomics or xenometabolomics. The higher development of biomarkers based on genomics or proteomics as omics older than metabolomics is discussed and also the potential role of metabolomics in systems biology taking into account its emergent implementation. Normalization of the volume of sampled sweat constitutes a present unsolved shortcoming that deserves investigation. Foreseeable trends in this area are outlined. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. A Proteomic Analysis of Eccrine Sweat: Implications for the Discovery of Schizophrenia Biomarker Proteins

    Science.gov (United States)

    Raiszadeh, Michelle M.; Ross, Mark M.; Russo, Paul S.; Schaepper, Mary Ann H.; Zhou, Weidong; Deng, Jianghong; Ng, Daniel; Dickson, April; Dickson, Cindy; Strom, Monica; Osorio, Carolina; Soeprono, Thomas; Wulfkuhle, Julia D.; Kabbani, Nadine; Petricoin, Emanuel F.; Liotta, Lance A.; Kirsch, Wolff M.

    2012-01-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) and multiple reaction monitoring mass spectrometry (MRM-MS) proteomics analyses were performed on eccrine sweat of healthy controls, and the results were compared with those from individuals diagnosed with schizophrenia (SZ). This is the first large scale study of the sweat proteome. First, we performed LC-MS/MS on pooled SZ samples and pooled control samples for global proteomics analysis. Results revealed a high abundance of diverse proteins and peptides in eccrine sweat. Most of the proteins identified from sweat samples were found to be different than the most abundant proteins from serum, which indicates that eccrine sweat is not simply a plasma transudate, and may thereby be a source of unique disease-associated biomolecules. A second independent set of patient and control sweat samples were analyzed by LC-MS/MS and spectral counting to determine qualitative protein differential abundances between the control and disease groups. Differential abundances of selected proteins, initially determined by spectral counting, were verified by MRM-MS analyses. Seventeen proteins showed a differential abundance of approximately two-fold or greater between the SZ pooled sample and the control pooled sample. This study demonstrates the utility of LC-MS/MS and MRM-MS as a viable strategy for the discovery and verification of potential sweat protein disease biomarkers. PMID:22256890

  9. Effects of stimulation technique, anatomical region, and time on human sweat lipid mediator profiles.

    Science.gov (United States)

    Agrawal, Karan; Waller, Justin D; Pedersen, Theresa L; Newman, John W

    2018-01-01

    Few studies compare sampling protocol effect on sweat composition. Here we evaluate the impact of sweat stimulation mode and site of collection on lipid mediator composition. Sweat from healthy males (n=7) was collected weekly for three weeks from the volar forearm following either pilocarpine iontophoresis or exercise, and from the forearm, back and thigh following pilocarpine iontophoresis only. Sweat content of over 150 lipid mediators were measured by liquid chromatography-tandem mass spectrometry. Seventy lipid mediators were routinely detected, including prostanoids, alcohols, diols, epoxides, ketones, nitrolipids, N-acylethanolamides, monoacylglycerols, and ceramides. Detected lipid mediators appeared unaffected by sampling site, though the forearm was the most consistent source of sweat. Pilocarpine-induced sweat showed increased concentrations of most detected compounds. Moreover, lipid mediator concentrations and profiles were temporally stable over the study duration. Sweat therefore appears to be a consistent and anatomically-stable source of lipid mediators, but care must be taken in comparing results obtained from different stimulation techniques. Published by Elsevier Inc.

  10. [Cholinergic urticaria successfully treated by immunotherapy with partially purified sweat antigen].

    Science.gov (United States)

    Tanaka, Toshihiko; Ishii, Kaori; Suzuki, Hidenori; Kameyoshi, Yoshikazu; Hide, Michihiro

    2007-01-01

    A 24-years-old man was referred to our University Hospital because of one and a half-year history of disabling symptoms related to physical exertion. Multiple small round-shaped wheals with severe itch were induced by exercise, warmth and psychological stress. These symptoms were resistant to histamine H1-receptor antagonists. Similar eruptions were induced by sauna-bathing, and skin test with autologous sweat showed a flare and wheal reaction. Incubation of his peripheral-blood leukocytes with partially purified sweat antigen evoked marked histamine release, indicating that he has been IgE-sensitized to an antigen(s) in human sweat. Specific immunotherapy using partially purified sweat antigen was performed every other week. Both pruritus and wheals improved gradually, and the reactivity of his peripheral blood leukocytes against sweat antigen decreased as immunotherapy was proceeded. Specific immunotherapy using sweat antigen may be valuable for patients with cholinergic urticaria with type I hypersensitivity to sweat antigen(s).

  11. SWEAT: Snow Water Equivalent with AlTimetry

    Science.gov (United States)

    Agten, Dries; Benninga, Harm-Jan; Diaz Schümmer, Carlos; Donnerer, Julia; Fischer, Georg; Henriksen, Marie; Hippert Ferrer, Alexandre; Jamali, Maryam; Marinaci, Stefano; Mould, Toby JD; Phelan, Liam; Rosker, Stephanie; Schrenker, Caroline; Schulze, Kerstin; Emanuel Telo Bordalo Monteiro, Jorge

    2017-04-01

    To study how the water cycle changes over time, satellite and airborne remote sensing missions are typically employed. Over the last 40 years of satellite missions, the measurement of true water inventories stored in sea and land ice within the cryosphere have been significantly hindered by uncertainties introduced by snow cover. Being able to determine the thickness of this snow cover would act to reduce such error, improving current estimations of hydrological and climate models, Earth's energy balance (albedo) calculations and flood predictions. Therefore, the target of the SWEAT (Snow Water Equivalent with AlTimetry) mission is to directly measure the surface Snow Water Equivalent (SWE) on sea and land ice within the polar regions above 60°and below -60° latitude. There are no other satellite missions currently capable of directly measuring SWE. In order to achieve this, the proposed mission will implement a novel combination of Ka- and Ku-band radioaltimeters (active microwave sensors), capable of penetrating into the snow microstructure. The Ka-band altimeter (λ ≈ 0.8 cm) provides a low maximum snow pack penetration depth of up to 20 cm for dry snow at 37 GHz, since the volume scattering of snow dominates over the scattering caused by the underlying ice surface. In contrast, the Ku-band altimeter (λ ≈ 2 cm) provides a high maximum snowpack penetration depth of up to 15 m in high latitudes regions with dry snow, as volume scattering is decreased by a factor of 55. The combined difference in Ka- and Ku-band signal penetration results will provide more accurate and direct determination of SWE. Therefore, the SWEAT mission aims to improve estimations of global SWE interpreted from passive microwave products, and improve the reliability of numerical snow and climate models.

  12. A Preliminary Study of Biomonitoring for Bisphenol-A in Human Sweat.

    Science.gov (United States)

    Porucznik, Christina A; Cox, Kyley J; Wilkins, Diana G; Anderson, David J; Bailey, Nicole M; Szczotka, Kathryn M; Stanford, Joseph B

    2015-09-01

    Measurement of human exposure to the endocrine disruptor bisphenol-A (BPA) is hampered by the ubiquitous but transient exposure for most individuals, coupled with a short metabolic half-life which leads to high inter- and intra-individual variability. We investigated the possibility of measuring multiday exposure to BPA in human sweat among volunteer participants with the goal of identifying an exposure assessment method less affected by temporal variability. We recruited 50 participants to wear a sweat collection patch (PharmChek(®)) for 7 days with concurrent collection of daily first-morning urine. Urines and sweat patch extracts were analyzed with quantitative LC-MS-MS using a method we previously validated. In addition, a human volunteer consumed one can of commercially available soup (16 oz, 473 cm(3)) daily for 3 days and collected urine. Sweat patches (n = 2, 1 per arm) were worn for the 3 days of the study. BPA was detected in quality control specimens prepared by fortification of BPA to sweat patches, but was only detected at 5× above average background on three participant patches. Although the highest measured urine BPA concentration was 195 ng/mL for an individual with deliberate exposure, no BPA was detected above background in the corresponding sweat patches. In this preliminary investigation, the use of sweat patches primarily worn on the upper-outer arm did not detect BPA exposures that were documented by urine monitoring. The absence of BPA in sweat patches may be due to several factors, including insufficient quantity of specimen per patch, or extremely low concentrations of BPA in naturally occurring sweat, among others. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Transition duration of ingested deuterium oxide to eccrine sweat during exercise in the heat.

    Science.gov (United States)

    Church, Adam; Lee, Fanny; Buono, Michael J

    2017-01-01

    The time necessary for the initial appearance of ingested water as sweat during exercise in the heat remains unknown. Based on the current literature, we estimated fluid transition through the body, from ingestion to appearance as sweat, to have a minimum time duration of approximately three minutes. The purpose of this study was to test this prediction and identify the time necessary for the initial enrichment of deuterium oxide (D2O) in sweat following ingestion during exercise in the heat. Eight participants performed moderate intensity (40% of maximal oxygen uptake) treadmill exercise in an environmental chamber (40°C, 40% rH) to induce active sweating. After fifteen minutes, while continuing to walk, participants consumed D2O (0.15mlkg-1) in a final volume of 50ml water. Scapular sweat samples were collected one minute prior to and ten minutes post-ingestion. Samples were analyzed for sweat D2O concentration using isotope ratio mass spectrometry and compared to baseline. Mean±SD ∆ sweat D2O concentration at minutes one and two post-ingestion were not significantly higher than baseline (0min). Minutes three (9±3ppm) through ten (23±11ppm) post-ingestion had ∆ sweat D2O concentrations significantly (P<0.05) higher than baseline. Such results suggest that ingested water rapidly transports across the mucosal membrane of the alimentary canal into the vasculature space, enters the extravascular fluid, and is actively secreted by the eccrine sweat glands onto the surface of the skin for potential evaporation in as little as three minutes during exercise in the heat. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Accumulation of 2H2O in plasma and eccrine sweat during exercise-heat stress.

    Science.gov (United States)

    Armstrong, Lawrence E; Klau, Jennifer F; Ganio, Matthew S; McDermott, Brendon P; Yeargin, Susan W; Lee, Elaine C; Maresh, Carl M

    2010-02-01

    The purpose of this research was to characterize the movement of ingested water through body fluids, during exercise-heat stress. Deuterium oxide ((2)H(2)O) accumulation in plasma and eccrine sweat was measured at two sites (back and forehead). The exercise of 14 males was controlled via cycle ergometry in a warm environment (60 min; 28.7 degrees C, 51%rh). Subjects consumed (2)H(2)O (0.15 mg kg(-1), 99.9% purity) mixed in flavored, non-caloric, colored water before exercise, then consumed 3.0 ml kg(-1) containing no (2)H(2)O every 15 min during exercise. We hypothesized that water transit from mouth to skin would occur before 15 min. (2)H(2)O appeared rapidly in both plasma and sweat (P deuterium accumulation (DeltaD:H min(-1)) in plasma was 14.9 and 23.7 times greater than in forehead and back sweat samples, respectively. Mean (+/-SE) whole-body sweat rate was 1.04 +/- 0.05 L h(-1) and subjects with the greatest whole-body sweat rate exhibited the greatest peak deuterium enrichment in sweat (r(2) = 0.87, exponential function); the peak (2)H(2)O enrichment in sweat was not proportional (P > 0.05) to body mass, volume of the deuterium dose, or total volume of fluid consumed. These findings clarify the time course of fluid movement from mouth to eccrine sweat glands, and demonstrate considerable differences of (2)H(2)O enrichment in plasma versus sweat.

  15. [Sweat chloride measurement using direct potentiometry: Spotchem(®) (Elitech-Arkray) evaluation and comparison with coulometry and conductivity].

    Science.gov (United States)

    Nguyen-Khoa, Thao; Borgard, Jean-Pierre; Miled, Ryad; Rota, Michèle

    2013-01-01

    Sweat chloride (Cl(-)) measurement is a key step for the diagnosis of cystic fibrosis. The coulometric technique is validated in this context by international guidelines. The aim of our study was to evaluate the assay for sweat Cl(-) ions using direct potentiometry on disposable cassette (Spotchem™ SE EL-1520, Elitech-Arkray) by comparing results to those obtained on the same sample, by coulometry (Chloride analyser Sherwood 926S, Dutscher). To complete our table of correspondence between the results of Cl(-) ions and sweat conductivity (Sweat Check™ 3100), conductivity has been also achieved for 99 of the 139 sweat samples studied. Linearity of each technique performed extends from 10 to 120 mmol/L. The coefficients of variation within and between runs are Sweat Cl(-) determinations using Spotchem™ analyser meet the criteria required by analytical recommendations. The technique is standardized, easy to perform and fast. Its good practicability makes the sweat test independent to operator and allows point-of care use.

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Pacific Islanders American Indian/Alaska Native Programs Older Adults Family Link Diabetes EXPO Upcoming Diabetes EXPOs EXPO ... Plate! Click on the plate sections below to add your food choices. Reset Plate Share Create Your ...

  17. Growth Plate Fractures

    Science.gov (United States)

    .org Growth Plate Fractures Page ( 1 ) The bones of children and adults share many of the same risks for ... also subject to a unique injury called a growth plate fracture. Growth plates are areas of cartilage ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... Plate! Click on the plate sections below to add your food choices. Reset Plate Share Create Your ... your protein. See this list of protein foods . Add a serving of fruit , a serving of dairy ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and ... Steps to Create Your Plate It's simple and effective for both managing diabetes and losing weight. Creating ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... that your options are endless. Create Your Plate! Click on the plate sections below to add your ... down the middle of the plate. Then on one side, cut it again so you will have ...

  1. The response of the malaria mosquito, Anopheles gambiae, to two components of human sweat, ammonia and L-lactic acid, in an olfactometer

    NARCIS (Netherlands)

    Braks, M.A.H.; Meijerink, J.; Takken, W.

    2001-01-01

    In an olfactometer study on the response of the anthropophilic malaria mosquito Anopheles gambiae s.s. (Diptera, Culicidae) to human sweat it was found that freshly collected sweat, mostly of eccrine origin, was attractive, but that incubated sweat was significantly more attractive than fresh sweat.

  2. Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

    Science.gov (United States)

    Gomez, Carla Cristina Souza; Servidoni, Maria de Fatima; Marson, Fernando Augusto de Lima; Canavezi, Paulo Jose Coelho; Vinagre, Adriana Mendes; Costa, Eduardo Tavares; Ribeiro, Antonio Fernando; Ribeiro, Maria Angela Gonçalves de Oliveira; Toro, Adyleia Aparecida Dalbo Contrera; Pavan, Celia Regina; Rondon, Michelle Vivine Sá Dos Santos; Lorena, Sonia Leticia Silva; Vieria, Francisco Ubaldi; Ribeiro, Jose Dirceu

    2014-12-13

    The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.

  3. PIXE analysis of cystic fibrosis sweat samples with an external proton beam

    Science.gov (United States)

    Sommer, F.; Massonnet, B.

    1987-03-01

    PIXE analysis with an external proton beam is used to study, in four control and five cystic fibrosis children, the elemental composition of sweat samples collected from different parts of the body during entire body hyperthermia. We observe no significant difference of sweat rates and of temperature variations between the two groups during sweat test. The statistical study of results obtained by PIXE analysis allows us to pick out amongst 8 elements studied, 6 elements (Na, Cl, Ca, Mn, Cu, Br) significatively different between the two groups of subjects. Using regression analysis, Na, Cl and Br concentrations could be used in a predictive equation of the state of health.

  4. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    Directory of Open Access Journals (Sweden)

    F. Meyer

    Full Text Available The dependence of sweat composition and acidity on sweating rate (SR suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac- and ammonia (NH3 and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men cycled in the heat (42ºC, 20% relative humidity at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During bout 1, sweat from girls and boys had higher Lac- concentrations (23.6 ± 1.2 and 21.2 ± 1.7 mM; P 0.05; r = -0.27. Sweat Lac- concentration dropped during exercise bout 2, reaching similar levels among all groups (overall mean = 13.7 ± 0.4 mM. Children had a higher sweat NH3 than adults during bout 1 (girls = 4.2 ± 0.4, boys = 4.6 ± 0.6, women = 2.7 ± 0.2, and men = 3.0 ± 0.2 mM; P < 0.05. This difference persisted through bout 2 only in females. On average, children's sweat pH was lower than that of adults (mean ± SEM, girls = 5.4 ± 0.2, boys = 5.0 ± 0.1, women = 6.2 ± 0.5, and men = 6.2 ± 0.4 for bout 1, and girls = 5.4 ± 0.2, boys = 6.5 ± 0.5, women = 5.2 ± 0.2, and men = 6.9 ± 0.4 for bout 2. This may have favored NH3 transport from plasma to sweat as accounted for by a significant correlation between sweat NH3 and H+ (r = 0.56. Blood pH increased from rest (mean ± SEM; 7.3 ± 0.02 to the end of exercise (7.4 ± 0.01 without differences among groups. These results, however, are representative of sweat induced by moderate exercise in the absence of acidosis.

  5. Effect of age and gender on sweat lactate and ammonia concentrations during exercise in the heat

    Directory of Open Access Journals (Sweden)

    F. Meyer

    2007-01-01

    Full Text Available The dependence of sweat composition and acidity on sweating rate (SR suggests that the lower SR in children compared to adults may be accompanied by a higher level of sweat lactate (Lac- and ammonia (NH3 and a lower sweat pH. Four groups (15 girls, 18 boys, 8 women, 8 men cycled in the heat (42ºC, 20% relative humidity at 50% VO2max for two 20-min bouts with a 10-min rest before bout 1 and between bouts. Sweat was collected into plastic bags attached to the subject's lower back. During bout 1, sweat from girls and boys had higher Lac- concentrations (23.6 ± 1.2 and 21.2 ± 1.7 mM; P 0.05; r = -0.27. Sweat Lac- concentration dropped during exercise bout 2, reaching similar levels among all groups (overall mean = 13.7 ± 0.4 mM. Children had a higher sweat NH3 than adults during bout 1 (girls = 4.2 ± 0.4, boys = 4.6 ± 0.6, women = 2.7 ± 0.2, and men = 3.0 ± 0.2 mM; P < 0.05. This difference persisted through bout 2 only in females. On average, children's sweat pH was lower than that of adults (mean ± SEM, girls = 5.4 ± 0.2, boys = 5.0 ± 0.1, women = 6.2 ± 0.5, and men = 6.2 ± 0.4 for bout 1, and girls = 5.4 ± 0.2, boys = 6.5 ± 0.5, women = 5.2 ± 0.2, and men = 6.9 ± 0.4 for bout 2. This may have favored NH3 transport from plasma to sweat as accounted for by a significant correlation between sweat NH3 and H+ (r = 0.56. Blood pH increased from rest (mean ± SEM; 7.3 ± 0.02 to the end of exercise (7.4 ± 0.01 without differences among groups. These results, however, are representative of sweat induced by moderate exercise in the absence of acidosis.

  6. Wearable sweat detector device design for health monitoring and clinical diagnosis

    Science.gov (United States)

    Wu, Qiuchen; Zhang, Xiaodong; Tian, Bihao; Zhang, Hongyan; Yu, Yang; Wang, Ming

    2017-06-01

    Miniaturized sensor is necessary part for wearable detector for biomedical applications. Wearable detector device is indispensable for online health care. This paper presents a concept of an wearable digital health monitoring device design for sweat analysis. The flexible sensor is developed to quantify the amount of hydrogen ions in sweat and skin temperature in real time. The detection system includes pH sensor, temperature sensor, signal processing module, power source, microprocessor, display module and so on. The sweat monitoring device is designed for sport monitoring or clinical diagnosis.

  7. Analysis of methamphetamine in hair, nail, sweat, and saliva by mass fragmentography.

    Science.gov (United States)

    Suzuki, S; Inoue, T; Hori, H; Inayama, S

    1989-01-01

    A method for the detection and quantitation of methamphetamine and its major metabolite in hair, nails, sweat, and saliva from habitual users of methamphetamine by mass fragmentography has been developed. Hair and nail samples were washed with water and methanol to remove the external contamination, processed with 0.6M HCl, alkalinized, and extracted with CHCl3/isopropanol (3:1 v/v). Sweat and saliva samples were extracted with methanol. After trifluoroacetyl derivatization, the samples were analyzed by mass fragmentography. Methamphetamine and its major metabolite, amphetamine, were detected in hair, nail, and sweat samples, but methamphetamine alone was detected in saliva samples.

  8. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans

    Science.gov (United States)

    2013-01-01

    Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6–2.3 L, with the hands (80–160 g.h−1) and feet (50–150 g.h−1) losing the most, the head and neck losing intermediate amounts (40–75 g.h−1) and all remaining sites losing 15–60 g.h−1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm−2) and the lowest on the upper lip (16 glands.cm−2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min−1, the forehead (0.99 mg.cm−2.min−1), dorsal fingers (0.62 mg.cm−2.min−1) and upper back (0.59 mg.cm−2.min−1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm−2.min−1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm−2.min−1, sodium losses of 26.5–49.7 mmol.L−1 could be expected, with the corresponding chloride loss being 26.8–36.7 mmol.L−1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise. PMID:23849497

  9. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans.

    Science.gov (United States)

    Taylor, Nigel As; Machado-Moreira, Christiano A

    2013-02-01

    Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6-2.3 L, with the hands (80-160 g.h-1) and feet (50-150 g.h-1) losing the most, the head and neck losing intermediate amounts (40-75 g.h-1) and all remaining sites losing 15-60 g.h-1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm-2) and the lowest on the upper lip (16 glands.cm-2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min-1, the forehead (0.99 mg.cm-2.min-1), dorsal fingers (0.62 mg.cm-2.min-1) and upper back (0.59 mg.cm-2.min-1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm-2.min-1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm-2.min-1, sodium losses of 26.5-49.7 mmol.L-1 could be expected, with the corresponding chloride loss being 26.8-36.7 mmol.L-1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise.

  10. Neurokinin B administration induces hot flushes in women.

    Science.gov (United States)

    Jayasena, Channa N; Comninos, Alexander N; Stefanopoulou, Evgenia; Buckley, Adam; Narayanaswamy, Shakunthala; Izzi-Engbeaya, Chioma; Abbara, Ali; Ratnasabapathy, Risheka; Mogford, Julianne; Ng, Noel; Sarang, Zubair; Ghatei, Mohammad A; Bloom, Stephen R; Hunter, Myra S; Dhillo, Waljit S

    2015-02-16

    Neurokinin B (NKB) is a hypothalamic neuropeptide binding preferentially to the neurokinin 3 receptor. Expression of the gene encoding NKB is elevated in postmenopausal women. Furthermore, rodent studies suggest that NKB signalling may mediate menopausal hot flushes. However, the effects of NKB administration on hot flushes have not been investigated in humans. To address this, we performed a randomised, double-blinded, placebo-controlled, 2-way cross-over study. Ten healthy women were admitted to a temperature and humidity-controlled research unit. Participants received 30 minute intravenous infusions of NKB and vehicle in random order. Symptoms, heart rate, blood pressure, sweating and skin temperature were compared between NKB and vehicle in a double-blinded manner. Eight of ten participants experienced flushing during NKB infusion with none experiencing flushing during vehicle infusion (P = 0.0007). Significant elevations in heart rate (P = 0.0106 vs. pre-symptoms), and skin temperature measured using skin probe (P = 0.0258 vs. pre-symptoms) and thermal imaging (P = 0.0491 vs. pre-symptoms) characteristic of menopausal flushing were observed during hot flush episodes. Our findings provide evidence that NKB administration can cause hot flushes in women. Further studies are required to determine if pharmacological blockade of NKB signalling could inhibit hot flushes during the menopause and during treatment for sex-steroid dependent cancers.

  11. Sound Radiation of Aerodynamically Excited Flat Plates into Cavities

    Directory of Open Access Journals (Sweden)

    Johannes Osterziel

    2017-10-01

    Full Text Available Flow-induced vibrations and the sound radiation of flexible plate structures of different thickness mounted in a rigid plate are experimentally investigated. Therefore, flow properties and turbulent boundary layer parameters are determined through measurements with a hot-wire anemometer in an aeroacoustic wind tunnel. Furthermore, the excitation of the vibrating plate is examined by laser scanning vibrometry. To describe the sound radiation and the sound transmission of the flexible aluminium plates into cavities, a cuboid-shaped room with adjustable volume and 34 flush-mounted microphones is installed at the non flow-excited side of the aluminium plates. Results showed that the sound field inside the cavity is on the one hand dependent on the flow parameters and the plate thickness and on the other hand on the cavity volume which indirectly influences the level and the distribution of the sound pressure behind the flexible plate through different excited modes.

  12. A case of localized adrenergic urticaria mimicking an allergic reaction to a sweat chloride test.

    Science.gov (United States)

    Klebanova, Y; LeGrys, V; Cooper, D; Levy, D; Santora, D; Schwindt, C

    2009-09-01

    Adrenergic urticaria (AU) is a rare type of physical urticaria triggered by stress. It is frequently confused with IgE-mediated urticaria or other physical urticarias. This report describes a case of localized adrenergic urticaria triggered by a sweat chloride test in an adolescent male with multiple atopic disorders. A pruritic papular rash at the site of a sweat chloride test prompted an evaluation for allergic and physical urticarias using multiple skin test methods. A positive intradermal skin test to noradrenaline, which reproduced the rash observed during the sweat test, lead to the diagnosis of adrenergic urticaria. This is the first case report describing an immediate adrenergic urticarial reaction to sweat chloride testing in a patient with other atopic disorders. Copyright 2009 Wiley-Liss, Inc.

  13. Abnormal Axon Reflex-Mediated Sweating Correlates with High State of Anxiety in Atopic Dermatitis

    Directory of Open Access Journals (Sweden)

    Akiko Kijima

    2012-01-01

    Conclusions: Although the number of study subjects was little, abnormal AXR sweating in patients with AD was observed. Correlative analysis suggests possible involvement of continuous anxiety and the immune system in such abnormal sudomotor function.

  14. Sweat Rate Prediction Equations for Outdoor Exercise with Transient Solar Radiation

    Science.gov (United States)

    2012-01-01

    clothing, aerobic fitness, and progressive dehydration . J Therm Biol 22: 331–342, 1997. 25. Matthew WT, Santee WR, Berglund LG. Solar Load Inputs for...code) Sweat rate prediction equations for outdoor exercise with transient solar radiation Richard R. Gonzalez,1 Samuel N. Cheuvront,2 Brett R. Ely,2...Moran DS, Hadid A, Endrusick TL, Sawka MN. Sweat rate prediction equations for outdoor exercise with transient solar radiation. J Appl Phys- iol 112

  15. System-level design of an RFID sweat electrolyte sensor patch.

    Science.gov (United States)

    Rose, Daniel P; Ratterman, M; Griffin, Daniel K; Hou, Linlin; Kelley-Loughnane, Nancy; Naik, Rajesh K; Hagen, Joshua A; Papautsky, I; Heikenfeld, Jason

    2014-01-01

    Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive RFID sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of mM ionic solutes in sweat, and surface temperature, as read by an Android smart-phone app (in-vitro tests).

  16. A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs)

    OpenAIRE

    Munje, Rujuta D.; Muthukumar, Sriram; Jagannath, Badrinath; Prasad, Shalini

    2017-01-01

    Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membran...

  17. Sweat composition in Arabian horses performing endurance exercise on forage-based, low Na rations.

    Science.gov (United States)

    Spooner, H S; Nielsen, B D; Schott, H C; Harris, P A

    2010-11-01

    Excessive sweat loss during endurance exercise may lead to electrolyte disturbances and previous research suggests dietary factors may affect hydration status. While investigating the effect of dietary fibre type on hydration status, sweat samples were collected which allowed for the evaluation of sweat composition in horses consuming forage-based, low sodium (Na) rations. To investigate sweat composition in Arabian horses performing endurance type exercise while fed forage-based, rations low in Na. Six 2-year-old Arabian horses were fed, according to a replicated 3 × 3 Latin square, either grass hay (G), 50:50 grass hay:alfalfa hay (GA), or 50:50 grass hay: chopped fibres (GM) without any additional electrolyte supplementation. After 14 days on each diet, horses performed a 60 km treadmill exercise test. Sweat was collected from sealed pouches on the dorsal thorax after each of four 15 km exercise bouts. Intake (g/day) of Na (2.5 ± 0.4), Cl (72 ± 16), and Mg (18 ± 3) were not different between diets but K and Ca intakes (g/day) were greater (P sweat pH (7.65 ± 0.04) or concentrations (mmol/l) of K (46 ± 3), Cl (133 ± 7), Ca (8.5 ± 1.1), or Mg (2.3 ± 0.3); yet diet did influence sweat Na concentration (P sweat constituents due to diet were observed, but more importantly both Na and Cl concentration are lower than those previously reported perhaps due to low dietary Na intake or breed of animal. © 2010 EVJ Ltd.

  18. Hydration profile and sweat loss perception of male and female division II basketball players during practice.

    Science.gov (United States)

    Thigpen, Lauren K; Green, James M; OʼNeal, Eric K

    2014-12-01

    Hydration affects multiple aspects of basketball performance, but few investigations have examined the hydration profiles of collegiate basketball players. We examined multiday prepractice hydration status of 11 male and 11 female NCAA (National Collegiate Athletic Association) Division II basketball players' sweat losses, fluid intake, and how accurately players estimated their sweat losses. Urine-specific gravity (USG) was spontaneously assessed before 2 practices. Sweat losses and fluid intakes were measured during a conditioning practice (CP) and sport-specific practice (SP). After practices, players filled 1,030 ml practice bottles to estimate their sweat losses. Urine-specific gravity between practices exhibited a moderate correlation (r = 0.54; p = 0.012) and were consistently high (17% of samples = USG >1.030) with no difference in mean USG between men (1.026 ± 0.004) and women (1.022 ± 0.008). Athletes' estimations of their sweat loss volumes between CP and the longer SP were strongly correlated (r = 0.88; p < 0.001). Estimation error was high (absolute error for both practices = 71 ± 52%) and error direction varied greatly within men. Women consistently underestimated sweat losses by 63 ± 28% and 65 ± 20% during CP and SP. Sweat losses during SP equaled 2,471 ± 495 ml and 1,910 ± 441 ml for men and women, respectively, but high practice fluid intake limited body mass losses to 1.1 ± 0.6% by the end of practice. It is plausible that hypohydration is related to poor conceptualization of sweat losses. Simulating the methodology of this study could help identify chronically hypohydrated athletes and be used to educate on between-practice fluid needs.

  19. A COMPARATIVE HISTOLOGICAL STUDY ON THE SWEAT GLAND OF CATTLE (B. INDICUS AND YAK (P. POEPHAGUS

    Directory of Open Access Journals (Sweden)

    Partha Das

    2014-12-01

    Full Text Available Yak and cattle are the species of different habitats, but are of the same genus Bos. In order to adapt to different habitats some changes may occur in cellular organizations, sweat gland morphology being one of the part of this cellular organization. The skin samples were collected from six adult nondescript male cattle and yak from five different anatomical regions viz., neck, dewlap, abdomen, back and prepuce. Sweat glands appeared tubular consisting of a secretary coil which was embedded in the dermis in cattle. In yak, the glands were saccular in the neck and dewlap regions and tubular in other regions. The sweat gland number (1729±3.44 in cattle was almost three times higher (P<0.01 than yak (615.82±3.44.Highest number of sweat gland population was found in back (1563.24±5.44 and lowest in abdomen (900.26±5.44 in both the species. Descending order of sweat gland number was detected in dewlap, neck and prepuce respectively in both the species. In cattle the sweat gland diameter was significantly (32.78±0.38 µm higher as compared to yak (27.68±0.38 ìm. The sweat gland number and nuclear diameter in cattle was more than yak. Acidophilic secretory granules of the glands were numerous in the supra-nuclear cytoplasm in case of cattle. These results suggest the hyper activity of sweat gland in controlling the thermo dynamics in cattle as compared to yak.

  20. Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat (Postprint)

    Science.gov (United States)

    2016-05-04

    lactate dehydrogenase; energy harvester (EH); micropotentiostat (MP) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT: SAR 18. NUMBER OF...Band-Aid like RFID sensor patches and temporary tattoo-based sensors have been developed for electrolyte and lactate sensing in sweat as part of on...2008. ISABEL’08. First International Symposium on. 2008. IEEE. 27. D. P. Rose et al., “Adhesive RFID sensor patch for monitoring of sweat electrolytes

  1. Thin, Soft, Skin-Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono-Sampling of Sweat.

    Science.gov (United States)

    Choi, Jungil; Kang, Daeshik; Han, Seungyong; Kim, Sung Bong; Rogers, John A

    2017-03-01

    Systems for time sequential capture of microliter volumes of sweat released from targeted regions of the skin offer the potential to enable analysis of temporal variations in electrolyte balance and biomarker concentration throughout a period of interest. Current methods that rely on absorbent pads taped to the skin do not offer the ease of use in sweat capture needed for quantitative tracking; emerging classes of electronic wearable sweat analysis systems do not directly manage sweat-induced fluid flows for sample isolation. Here, a thin, soft, "skin-like" microfluidic platform is introduced that bonds to the skin to allow for collection and storage of sweat in an interconnected set of microreservoirs. Pressure induced by the sweat glands drives flow through a network of microchannels that incorporates capillary bursting valves designed to open at different pressures, for the purpose of passively guiding sweat through the system in sequential fashion. A representative device recovers 1.8 µL volumes of sweat each from 0.8 min of sweating into a set of separate microreservoirs, collected from 0.03 cm 2 area of skin with approximately five glands, corresponding to a sweat rate of 0.60 µL min -1 per gland. Human studies demonstrate applications in the accurate chemical analysis of lactate, sodium, and potassium concentrations and their temporal variations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.

    Science.gov (United States)

    Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F

    2014-02-01

    The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.

  3. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat.

    Science.gov (United States)

    Koh, Ahyeon; Kang, Daeshik; Xue, Yeguang; Lee, Seungmin; Pielak, Rafal M; Kim, Jeonghyun; Hwang, Taehwan; Min, Seunghwan; Banks, Anthony; Bastien, Philippe; Manco, Megan C; Wang, Liang; Ammann, Kaitlyn R; Jang, Kyung-In; Won, Phillip; Han, Seungyong; Ghaffari, Roozbeh; Paik, Ungyu; Slepian, Marvin J; Balooch, Guive; Huang, Yonggang; Rogers, John A

    2016-11-23

    Capabilities in health monitoring enabled by capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible, and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of the skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose, and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH, and concentration of chloride and lactate. Copyright © 2016, American Association for the Advancement of Science.

  4. Estimation of sweat rates during cycling exercise by means of the closed chamber condenser technology.

    Science.gov (United States)

    Clarys, P; Clijsen, R; Barel, A O; Schouteden, R; van Olst, B; Aerenhouts, D

    2017-02-01

    Knowledge of local sweating patterns is of importance in occupational and exercise physiology settings. The recently developed closed chamber condenser technology (Biox Aquaflux ® ) allows the measurement of evaporative skin water loss with a greater measurement capacity (up to 1325 g/h/m 2 ) compared to traditional evaporimeters. The aim of this study was to evaluate the applicability of the Biox Aquaflux ® to estimate sweat production during exercise. Fourteen healthy subjects performed a 20-min cycle ergometer trial at respectively 55% heart rate (HR reserve and 75% HR reserve . Sweat production was estimated by measuring body weight before and after exercise, by calculating the amount of sweat collected in a patch, and by measuring the water flux (in g/h/m 2 ) with the Biox Aquaflux ® instrument. The Biox Aquaflux ® instrument allowed the follow up of sweat kinetics at both intensities. Correlations between the measurement methods were all significant for the 75% HR reserve trial (with r ranging from 0.68 to 0.76) whilst for the 55% HR reserve a significant relation was detected between the patch method and the Biox Aquaflux ® only (with r ranging from 0.41 to 0.79). The Biox Aquaflux ® instrument is a practical and direct method for the estimation of local sweat rates under field conditions. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Noninvasive monitoring of plasma L-dopa concentrations using sweat samples in Parkinson's disease.

    Science.gov (United States)

    Tsunoda, Makoto; Hirayama, Masaaki; Tsuda, Takao; Ohno, Kinji

    2015-03-10

    L-dopa (l-3,4-dihydroxyphenylalanine) is commonly used for treating Parkinson's disease (PD). However, regardless of its prominent effect, therapeutic range of L-dopa narrows down with disease progression, which leads to development of motor complications including wearing off and dyskinesias. In addition, intestinal absorption of L-dopa is inversely correlated with the amount of oral protein intake, and shows intra- and inter-day variability. Hence, frequent monitoring of plasma L-dopa concentrations is beneficial, but frequent venipuncture imposes physical and psychological burdens on patients with PD. We investigated the usefulness of sweat samples instead of plasma samples for monitoring L-dopa concentrations. With a monolithic silica disk-packed spin column and the high-performance liquid chromatography-electrochemical detection system, L-dopa in sweat samples was successfully quantified and analyzed in 23 PD patients. We found that the Pearson's correlation coefficient of the plasma and sweat l-dopa concentrations was 0.678. Although the disease durations and severities were not correlated with the deviation of the actual sweat L-dopa concentrations from the fitted line, acquisition of the sweat samples under a stable condition was technically difficult in severely affected patients. The deviations may also be partly accounted for by skin permeability of L-dopa. Measuring L-dopa concentrations in sweat is suitable to get further insights into the L-dopa metabolism. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module

    Science.gov (United States)

    Lee, Hyunjae; Song, Changyeong; Hong, Yong Seok; Kim, Min Sung; Cho, Hye Rim; Kang, Taegyu; Shin, Kwangsoo; Choi, Seung Hong; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2017-01-01

    Electrochemical analysis of sweat using soft bioelectronics on human skin provides a new route for noninvasive glucose monitoring without painful blood collection. However, sweat-based glucose sensing still faces many challenges, such as difficulty in sweat collection, activity variation of glucose oxidase due to lactic acid secretion and ambient temperature changes, and delamination of the enzyme when exposed to mechanical friction and skin deformation. Precise point-of-care therapy in response to the measured glucose levels is still very challenging. We present a wearable/disposable sweat-based glucose monitoring device integrated with a feedback transdermal drug delivery module. Careful multilayer patch design and miniaturization of sensors increase the efficiency of the sweat collection and sensing process. Multimodal glucose sensing, as well as its real-time correction based on pH, temperature, and humidity measurements, maximizes the accuracy of the sensing. The minimal layout design of the same sensors also enables a strip-type disposable device. Drugs for the feedback transdermal therapy are loaded on two different temperature-responsive phase change nanoparticles. These nanoparticles are embedded in hyaluronic acid hydrogel microneedles, which are additionally coated with phase change materials. This enables multistage, spatially patterned, and precisely controlled drug release in response to the patient’s glucose level. The system provides a novel closed-loop solution for the noninvasive sweat-based management of diabetes mellitus. PMID:28345030

  7. Sweat lipid mediator profiling: a noninvasive approach for cutaneous research[S

    Science.gov (United States)

    Hassoun, Lauren A.; Foolad, Negar; Pedersen, Theresa L.; Sivamani, Raja K.; Newman, John W.

    2017-01-01

    Recent advances in analytical and sweat collection techniques provide new opportunities to identify noninvasive biomarkers for the study of skin inflammation and repair. This study aims to characterize the lipid mediator profile including oxygenated lipids, endocannabinoids, and ceramides/sphingoid bases in sweat and identify differences in these profiles between sweat collected from nonlesional sites on the unflared volar forearm of subjects with and without atopic dermatitis (AD). Adapting routine procedures developed for plasma analysis, over 100 lipid mediators were profiled using LC-MS/MS and 58 lipid mediators were detected in sweat. Lipid mediator concentrations were not affected by sampling or storage conditions. Increases in concentrations of C30–C40 [NS] and [NdS] ceramides, and C18:1 sphingosine, were observed in the sweat of study participants with AD despite no differences being observed in transepidermal water loss between study groups, and this effect was strongest in men (P Sweat mediator profiling may therefore provide a noninvasive diagnostic for AD prior to the presentation of clinical signs. PMID:27875258

  8. Lack of harmonization in sweat testing for cystic fibrosis - a national survey.

    Science.gov (United States)

    Christiansen, Anne Lindegaard; Nybo, Mads

    2014-11-01

    Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study was to investigate how performance of the test is organized in Denmark. Departments conducting the sweat test were contacted and interviewed following a premade questionnaire. They were asked about methods performed, applied NPU (Nomenclature for Properties and Units) code, reference interval, recommended interpretation and referred literature. 14 departments performed the sweat test. One department measured chloride and sodium concentration, while 13 departments measured conductivity. One department used a non-existing NPU code, two departments applied NPU codes inconsistent with the method performed, four departments applied no NPU code and seven applied a correct NPU code. Ten of the departments measuring conductivity applied reference intervals. Nine departments measuring conductivity had recommendations of a normal area, a grey zone and a pathological value, while four departments only applied a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use.

  9. Stretchable, wireless sensors and functional substrates for epidermal characterization of sweat.

    Science.gov (United States)

    Huang, Xian; Liu, Yuhao; Chen, Kaile; Shin, Woo-Jung; Lu, Ching-Jui; Kong, Gil-Woo; Patnaik, Dwipayan; Lee, Sang-Heon; Cortes, Jonathan Fajardo; Rogers, John A

    2014-08-13

    This paper introduces materials and architectures for ultrathin, stretchable wireless sensors that mount on functional elastomeric substrates for epidermal analysis of biofluids. Measurement of the volume and chemical properties of sweat via dielectric detection and colorimetry demonstrates some capabilities. Here, inductively coupled sensors consisting of LC resonators with capacitive electrodes show systematic responses to sweat collected in microporous substrates. Interrogation occurs through external coils placed in physical proximity to the devices. The substrates allow spontaneous sweat collection through capillary forces, without the need for complex microfluidic handling systems. Furthermore, colorimetric measurement modes are possible in the same system by introducing indicator compounds into the depths of the substrates, for sensing specific components (OH(-) , H(+) , Cu(+) , and Fe(2+) ) in the sweat. The complete devices offer Young's moduli that are similar to skin, thus allowing highly effective and reliable skin integration without external fixtures. Experimental results demonstrate volumetric measurement of sweat with an accuracy of 0.06 μL/mm(2) with good stability and low drift. Colorimetric responses to pH and concentrations of various ions provide capabilities relevant to analysis of sweat. Similar materials and device designs can be used in monitoring other body fluids. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Higher sweat chloride levels in patients with asthma: a case-control study.

    Science.gov (United States)

    Awasthi, Shally; Dixit, Pratibha; Maurya, Nutan

    2015-02-01

    To screen asthmatic patients by sweat chloride test to identify proportion with Cystic Fibrosis (CF); (Sweat chloride level >60 mmol/L). Also, to compare sweat chloride levels between cases of bronchial asthma and age and sex matched healthy children aged 5 mo-15 y. The present case-control study was conducted in a tertiary care hospital in India. Cases of bronchial asthma, diagnosed by GINA guideline 2008, and age matched healthy controls were included. Case to control ratio was 2:1. Sweat Chloride test was done by Pilocarpine Iontophoresis method. From April 2010 through May 2012, 216 asthmatics and 112 controls were recruited. Among asthmatics, there was no case of Cystic Fibrosis. Mean sweat chloride levels in asthmatics was 22.39 ± 8.45 mmol/L (inter-quartile range - 15-28 mmol/L) and in controls 19.55 ± 7.04 mmol/L (inter-quartile range - 15-23.5 mmol/L) (p value = 0.048). No Cystic Fibrosis case was identified among asthmatics. Mean sweat chloride levels were higher in asthmatics as compared to controls.

  11. Rate and composition of sweat fluid losses are unaltered by hypohydration during prolonged exercise in horses.

    Science.gov (United States)

    Kingston, J K; Geor, R J; McCutcheon, L J

    1997-10-01

    Rate and ionic composition of sweat fluid losses and partitioning of evaporative heat loss into respiratory and cutaneous components were determined in six horses during three 15-km phases of exercise at approximately 40% of maximal O2 uptake. Pattern of change in sweat rate (SR) and composition was similar during each phase. SR increased rapidly for the first 20 min of exercise but remained at approximately 24-28 ml . m-2 . min-1 during the remainder of each phase. Similarly, the concentrations of Na and Cl in sweat increased until 30 min of exercise but were unchanged thereafter. Sweat osmolality and concentrations of Na and Cl were positively correlated with SR. Sweat K concentration decreased during exercise but was not correlated with SR. Fluid losses were 33.8 +/- 1.5 liters, resulting in decreases of approximately 21% in plasma volume and approximately 11% in total body water. The approximately 6% hypohydration was not associated with an alteration in SR, sweat composition, or heat storage. Respiratory and cutaneous evaporative heat loss represented approximately 23 and 70%, respectively, of the total heat dissipated, and the partitioning of heat loss was similar in each exercise phase. We conclude that SR and the relative proportions of respiratory and cutaneous evaporative heat loss are unchanged in horses during prolonged low-intensity exercise despite moderate hypohydration.

  12. A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs).

    Science.gov (United States)

    Munje, Rujuta D; Muthukumar, Sriram; Jagannath, Badrinath; Prasad, Shalini

    2017-05-16

    Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membranes. Temporal studies were performed using both infrared spectroscopic, dynamic light scattering, and impedimetric spectroscopy to demonstrate stability in detection of analytes, Interleukin-6 (IL-6) and Cortisol, from human sweat in RTILs. Temporal stability in sensor performance was performed as follows: (a) detection of target analytes after 0, 24, 48, 96, and 168 hours post-antibody sensor functionalization; and (b) continuous detection of target analytes post-antibody sensor functionalization. Limit of detection of IL-6 in human sweat was 0.2 pg/mL for 0-24 hours and 2 pg/mL for 24-48 hours post-antibody sensor functionalization. Continuous detection of IL-6 over 0.2-200 pg/mL in human sweat was demonstrated for a period of 10 hours post-antibody sensor functionalization. Furthermore, combinatorial detection of IL-6 and Cortisol in human sweat was established with minimal cross-talk for 0-48 hours post-antibody sensor functionalization.

  13. Higher sweating rate and skin blood flow during the luteal phase of the menstrual cycle.

    Science.gov (United States)

    Lee, Haneul; Petrofsky, Jerrold; Shah, Nirali; Awali, Abdulaziz; Shah, Karan; Alotaibi, Mohammed; Yim, JongEun

    2014-10-01

    Evaporation by sweating is the most effective way to remove heat from the body. Sweat rates increase under both local and whole-body heat stress. Men and women differ in how they respond to heat, because sexual steroids alter resting body core temperature and the threshold for sweating and skin blood flow (SBF) during heating. The purpose of the present study was to compare local sweat rates and cutaneous vasodilatation during heat exposure in women with a regular menstrual cycle. The cutaneous vasodilatation was judged by measuring the SBF. Eight female and nine male subjects participated in this study, and their age range was 24-29 years. Female subjects were tested twice throughout one full menstrual cycle: once during the middle follicular phases and once during the luteal phase. Subjects remained in a temperature-regulated room at 41°C and 21% of relative humidity for 40 minutes. Sweat rate was recorded from the forehead, forearm, and thigh, and skin temperature and SBF were measured on the thigh and forehead. We found that the sweating rate and SBF were greater in the luteal phase compared to follicular phase (p0.05). We propose the enhanced sympathetic activity in the luteal phase with a regular menstrual cycle.

  14. Control of sweating in man after work-induced thermal load and symmetrically applied cooling.

    Science.gov (United States)

    Heising, M; Werner, J

    1987-01-01

    To examine the compensatory effects of work-induced thermal load and symmetrically applied local cooling on local sweat rates, two kinds of experiment were carried out on eight male subjects in a climatic chamber: 1) Experiments at 36 degrees C ambient temperature with a work load of about 25 W by the right leg. 2) Experiments at 36 degrees C ambient temperature with a work load of about 25 W by the right leg as in 1., but with additional compensatory cooling of the left leg controlled throughout by heat balance calculations at 75-85 W, equal to the heat produced in the working leg, the necessary air temperature being dependent on local sweat rate. Work load without cooling brought about a significant increase in core temperatures, metabolism, heart rate and local sweat rates. With unchanged local skin temperatures local sweat rate increase was higher in the working leg. Therefore the existence of muscle thermoreceptors should be assumed, the afferent information from which is processed and weighted in a different way to that provided by skin receptors. Work load combined with additional cooling reduced local and mean skin temperatures and heart rate, but had no significant influence on core temperature or metabolism. However, local sweat rate was generally lower in both thighs, with a major reduction in the cooled leg confirming control of local sweat rate by local temperature.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Normative data on regional sweat-sodium concentrations of professional male team-sport athletes.

    Science.gov (United States)

    Ranchordas, Mayur K; Tiller, Nicholas B; Ramchandani, Girish; Jutley, Raj; Blow, Andrew; Tye, Jonny; Drury, Ben

    2017-01-01

    The purpose of this paper was to report normative data on regional sweat sweat-sodium concentrations of various professional male team-sport athletes, and to compare sweat-sodium concentrations among sports. Data to this effect would inform our understanding of athlete sodium requirements, thus allowing for the individualisation of sodium replacement strategies. Accordingly, data from 696 athletes (Soccer, n = 270; Rugby, n = 181; Baseball, n = 133; American Football, n = 60; Basketball, n = 52) were compiled for a retrospective analysis. Regional sweat-sodium concentrations were collected using the pilocarpine iontophoresis method, and compared to self-reported measures collected via questionnaire. Sweat-sodium concentrations were significantly higher (p sports. There were strong positive correlations between sweat-sodium concentrations and self-reported sodium losses in American football (rs = 0.962, p sports science/medicine practitioners in generating bespoke hydration and electrolyte-replacement strategies to meet the sodium demands of professional team-sport athletes. Moreover, these novel data suggest that self-reported measures of sodium loss might serve as an effective surrogate in the absence of direct measures; i.e., those which are more expensive or non-readily available.

  16. Maximum rate of sweat ions reabsorption during exercise with regional differences, sex, and exercise training.

    Science.gov (United States)

    Amano, Tatsuro; Hirose, Megumi; Konishi, Kana; Gerrett, Nicola; Ueda, Hiroyuki; Kondo, Narihiko; Inoue, Yoshimitsu

    2017-07-01

    It is recently reported that determining sweat rate (SR) threshold for increasing galvanic skin conductance (GSC) would represent a maximum rate of sweat ion reabsorption in sweat glands. We evaluate the maximum rate of sweat ion reabsorption over skin regions, sex, and long-term exercise training by using the threshold analysis in the present study. Ten males (2 untrained, 4 sprinters, and 4 distance runners) and 12 females (5 untrained, 4 sprinters, and 3 distance runners) conducted graded cycling exercise for 45 min at low, middle, and high exercise intensities (heart rate 100-110, 120-130, and 140-150 beats/min, respectively) for 10, 15, and 20 min, respectively, at 30 °C and 50% relative humidity. Comparisons were made between males and females and among untrained individuals, distance runners, and sprinters on the back and forearm. SR threshold for increasing GSC on back was significantly higher than that of forearm (P sprinters showed higher SR threshold for increasing GSC than that of untrained subjects on back (P sprinters, respectively). These results suggest that the maximum sweat ion reabsorption rate on the back is higher than that of forearm without sex differences. Furthermore, exercise training in distance runners and sprinters improves the maximum sweat ion reabsorption rate on the back.

  17. Current plate motions

    Science.gov (United States)

    Demets, C.; Gordon, R. G.; Argus, D. F.; Stein, S.

    1990-05-01

    A global plate motion model, named NUVEL-1, which describes current plate motions between 12 rigid plates is described, with special attention given to the method, data, and assumptions used. Tectonic implications of the patterns that emerged from the results are discussed. It is shown that wide plate boundary zones can form not only within the continental lithosphere but also within the oceanic lithosphere; e.g., between the Indian and Australian plates and between the North American and South American plates. Results of the model also suggest small but significant diffuse deformation of the oceanic lithosphere, which may be confined to small awkwardly shaped salients of major plates.

  18. Episodic plate tectonics on Venus

    Science.gov (United States)

    Turcotte, Donald

    1992-01-01

    Studies of impact craters on Venus from the Magellan images have placed important constraints on surface volcanism. Some 840 impact craters have been identified with diameters ranging from 2 to 280 km. Correlations of this impact flux with craters on the Moon, Earth, and Mars indicate a mean surface age of 0.5 +/- 0.3 Ga. Another important observation is that 52 percent of the craters are slightly fractured and only 4.5 percent are embayed by lava flows. These observations led researchers to hypothesize that a pervasive resurfacing event occurred about 500 m.y. ago and that relatively little surface volcanism has occurred since. Other researchers have pointed out that a global resurfacing event that ceased about 500 MYBP is consistent with the results given by a recent study. These authors carried out a series of numerical calculations of mantle convection in Venus yielding thermal evolution results. Their model considered crustal recycling and gave rapid planetary cooling. They, in fact, suggested that prior to 500 MYBP plate tectonics was active in Venus and since 500 MYBP the lithosphere has stabilized and only hot-spot volcanism has reached the surface. We propose an alternative hypothesis for the inferred cessation of surface volcanism on Venus. We hypothesize that plate tectonics on Venus is episodic. Periods of rapid plate tectonics result in high rates of subduction that cool the interior resulting in more sluggish mantle convection.

  19. New functions and applications of walter, the sweating fabric manikin.

    Science.gov (United States)

    Fan, Jintu; Qian, Xiaoming

    2004-09-01

    In this paper, latest developments on Walter, a sweating fabric manikin, are reported. These include the improved simulation of "walking motion", the design and construction of an automated water supply, and real-time measurement of evaporative water loss and regulation of "skin" temperature through the regulation of the pumps inside the manikin body. Testing of commercial garment ensembles showed that the measurement of thermal insulation and moisture-vapour resistance of clothing is very reproducible with the coefficient of variation being generally less than 5%. It was also shown that, in addition to the thermal insulation and moisture-vapour resistance, the percentage of moisture accumulation within clothing is a very useful parameter of clothing comfort. The improved manikin has been used to investigate the effects of walking motion on thermal insulation and evaporative resistance of clothing. The trend of the effects of walking speed up to 1.13 m s(-1) for the nude manikin and when it was wearing garments of different sizes are reported.

  20. Corrosion Performance of Cu-Based Coins in Artificial Sweat

    Directory of Open Access Journals (Sweden)

    J. Porcayo-Calderon

    2016-01-01

    Full Text Available The performance of different Cu-based coins in artificial sweat was evaluated. The electrochemical behavior of the coins was determined by potentiodynamic polarization curves, linear polarization resistance, and electrochemical impedance spectroscopy. Regardless of the chemical composition of the Cu-based coins, they showed similar polarization curves; particularly, the observed similarity in the anodic zone suggests that the corrosion mechanism is the same in all cases. The presence of Ni and Zn does not appreciably affect the corrosion resistance of Cu. However, the presence of both elements affects the corrosion resistance of Cu. Electrochemical impedance spectroscopy measurements showed the presence of three time constants with very similar characteristics, again indicating that the main corrosion mechanism is the same in all cases. Equivalent circuits confirmed that the corrosion performance of the Ni-Zn-Cu coins depends on the Zn/Ni ratio, such that decreasing this value decreases the corrosion resistance of the alloy. In general, nickel has a detrimental effect due to the formation of highly soluble Ni-based corrosion products.

  1. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C.

    Science.gov (United States)

    Dunstan, R Hugh; Sparkes, Diane L; Dascombe, Benjamin J; Macdonald, Margaret M; Evans, Craig A; Stevens, Christopher J; Crompton, Marcus J; Gottfries, Johan; Franks, Jesse; Murphy, Grace; Wood, Ryan; Roberts, Timothy K

    2016-01-01

    Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF) produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32-34°C and 20-30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as "faux" sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine, serine, glycine

  2. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C.

    Directory of Open Access Journals (Sweden)

    R Hugh Dunstan

    Full Text Available Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32-34°C and 20-30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as "faux" sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine

  3. Variability of sweat chloride concentration in subjects with cystic fibrosis and G551D mutations.

    Science.gov (United States)

    Vermeulen, F; Le Camus, C; Davies, J C; Bilton, D; Milenković, D; De Boeck, K

    2017-01-01

    Sweat chloride concentration, a biomarker of CFTR function, is an appropriate outcome parameter in clinical trials aimed at correcting the basic CF defect. Although there is consensus on a cut-off value to diagnose CF, we have only limited information on the within subject variability of sweat chloride over time. Such information would be useful for sample size calculations in clinical trials. Therefore, we retrospectively analyzed repeated sweat chloride values obtained in patients with G551D mutation(s) assigned to placebo in an ivacaftor interventional trial. In subjects with G551D at least 12years of age, a pilocarpine sweat test using Macroduct collector was taken on both arms at 8 time points over 48weeks. We explored 1062 pilocarpine sweat test values obtained in 78 placebo patients of the VX08-770-102 trial. Mean overall sweat chloride value (all patients, all tests, n=1062) was 100.8mmol/L (SD 12.7mmol/L). Using a multilevel mixed model, the between-subject standard deviation (SD) for sweat chloride was 8.9mmol/L (95% CI 7.4-10.6) and within-subject SD was 8.1mmol/L (95% CI 7.5-8.7). Limits of repeatability for repeat measurements were -19.7 to +21.6mmol/L using values from one arm, and -13.3 to 11.8mmol/L using mean of values obtained at 4 test occasions. Sample size calculations showed that the minimal treatment effect on sweat chloride concentration that can be demonstrated for a group of 5 patients is around 15mmol/L, using a cross-over design and combinations of 4 tests for each phase of the trial. Although the sweat test is considered a robust measure, sweat chloride measurements in patients with CF and a G551D mutation had an inherent biological variability that is higher than commonly considered. Further analyses of placebo group data are crucial to learn more about the natural variability of this outcome parameter. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  4. Normal sweat secretion despite impaired growth hormone-insulin-like growth factor-I axis in obese subjects

    DEFF Research Database (Denmark)

    Rasmussen, Michael Højby; Juul, Anders; Main, Katharina M

    2011-01-01

    Adults with GH deficiency are known to exhibit reduced sweating. Whether sweating capacity is impacted in obese subjects with impaired GH secretion have not previously been investigated. The main objective was to investigate sweat secretion rate and the GH-IGF-I axis in obese subjects before......, and impaired insulin sensitivity, which all were normalised after diet-induced weight loss of 30 ± 5 kg. Sweat secretion rates were similar comparing obese and nonobese subjects (78 ± 10 versus 82 ± 9 mg/30 minutes) and sweat secretion did not change after a diet-induced weight loss in obese subjects. We...... conclude that although obese subjects have markedly reduced GH release and impaired IGF-I levels, sweat secretion rate is found to be normal....

  5. Association of sweat chloride concentration at time of diagnosis and CFTR genotype with mortality and cystic fibrosis phenotype.

    Science.gov (United States)

    McKone, Edward F; Velentgas, Priscilla; Swenson, Anna J; Goss, Christopher H

    2015-09-01

    The extent to which sweat chloride concentration predicts survival and clinical phenotype independently of CFTR genotype in cystic fibrosis is not well understood. We analyzed the US Cystic Fibrosis Foundation Patient Registry data using Cox regression to examine the relationship between sweat chloride concentration (sweat chloride, CFTR genotype, and measures of lung function and growth. When included in the same model, CFTR genotype, but not sweat chloride, was independently associated with survival and with lung function, height, and BMI. Among patients with unclassified CFTR genotype, sweat chloride was an independent predictor of survival (Sweat chloride concentration may be a useful predictor of mortality and clinical phenotype when CFTR genotype functional class is unclassified. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  6. Increase in dermcidin-derived peptides in sweat of patients with atopic eczema caused by a humorous video.

    Science.gov (United States)

    Kimata, Hajime

    2007-01-01

    Dermcidin (DCD)-derived peptide is an antimicrobial peptide produced by the sweat glands. However, the levels of DCD-derived peptide in sweat were decreased in patients with atopic eczema (AE). The effect of viewing a humorous video on the levels of DCD-derived peptide was studied. Twenty patients with AE viewed an 87-min humorous video (Modern Times, featuring Charlie Chaplin). Just before and immediately after viewing, sweat was collected, and the levels of DCD-derived peptide and total protein in sweat were measured. Viewing a humorous video increased the levels of DCD-derived peptide without affecting the levels of total protein in sweat. Viewing a humorous video increased DCD-derived peptide in sweat of patients with AE, and thus, it may be helpful in the treatment of skin infection of AE.

  7. Heat transfer studies on spiral plate heat exchanger

    Directory of Open Access Journals (Sweden)

    Rajavel Rangasamy

    2008-01-01

    Full Text Available In this paper, the heat transfer coefficients in a spiral plate heat exchanger are investigated. The test section consists of a plate of width 0.3150 m, thickness 0.001 m and mean hydraulic diameter of 0.01 m. The mass flow rate of hot water (hot fluid is varying from 0.5 to 0.8 kg/s and the mass flow rate of cold water (cold fluid varies from 0.4 to 0.7 kg/s. Experiments have been conducted by varying the mass flow rate, temperature, and pressure of cold fluid, keeping the mass flow rate of hot fluid constant. The effects of relevant parameters on spiral plate heat exchanger are investigated. The data obtained from the experimental study are compared with the theoretical data. Besides, a new correlation for the Nusselt number which can be used for practical applications is proposed.

  8. Solar hot water system installed at Las Vegas, Nevada

    Science.gov (United States)

    1981-01-01

    A solar energy hot water system installed in a motor inn at Las Vegas, Nevada is described. The inn is a three story building with a flat roof for installation of the solar panels. The system consists of 1,200 square feet of liquid flat plate collectors, a 2,500 gallon insulated vertical steel storage tank, two heat exchangers, and pumps and controls. The system was designed to supply approximately 74 percent of the total hot water load.

  9. Epidermal Microfluidic Electrochemical Detection System: Enhanced Sweat Sampling and Metabolite Detection.

    Science.gov (United States)

    Martín, Aida; Kim, Jayoung; Kurniawan, Jonas F; Sempionatto, Juliane R; Moreto, Jose R; Tang, Guangda; Campbell, Alan S; Shin, Andrew; Lee, Min Yul; Liu, Xiaofeng; Wang, Joseph

    2017-12-22

    Despite tremendous recent efforts, noninvasive sweat monitoring is still far from delivering its early analytical promise. Here, we describe a flexible epidermal microfluidic detection platform fabricated through hybridization of lithographic and screen-printed technologies, for efficient and fast sweat sampling and continuous, real-time electrochemical monitoring of glucose and lactate levels. This soft, skin-mounted device judiciously merges lab-on-a-chip and electrochemical detection technologies, integrated with a miniaturized flexible electronic board for real-time wireless data transmission to a mobile device. Modeling of the device design and sweat flow conditions allowed optimization of the sampling process and the microchannel layout for achieving attractive fluid dynamics and rapid filling of the detection reservoir (within 8 min from starting exercise). The wearable microdevice thus enabled efficient natural sweat pumping to the electrochemical detection chamber containing the enzyme-modified electrode transducers. The fabricated device can be easily mounted on the epidermis without hindrance to the wearer and displays resiliency against continuous mechanical deformation expected from such epidermal wear. Amperometric biosensing of lactate and glucose from the rapidly generated sweat, using the corresponding immobilized oxidase enzymes, was wirelessly monitored during cycling activity of different healthy subjects. This ability to monitor sweat glucose levels introduces new possibilities for effective diabetes management, while similar lactate monitoring paves the way for new wearable fitness applications. The new epidermal microfluidic electrochemical detection strategy represents an attractive alternative to recently reported colorimetric sweat-monitoring methods, and hence holds considerable promise for practical fitness or health monitoring applications.

  10. Long-term outcomes of children with intermediate sweat chloride values in infancy.

    Science.gov (United States)

    Groves, Tyler; Robinson, Paul; Wiley, Veronica; Fitzgerald, Dominic A

    2015-06-01

    To describe the clinical course of children who have intermediate sweat chloride values on initial screening for cystic fibrosis (CF). We performed a retrospective review of children with intermediate sweat chloride values (raised immunoreactive trypsinogen/1 copy of p.F508del CF mutation on newborn screening (NBS)/sweat chloride value of 30-59 mmol/L) presenting to The Children's Hospital at Westmead over 15 years. Patients with an intermediate sweat chloride evolving to a formal diagnosis of CF (termed "delayed CF") were matched (2:1) with NBS positive patients with CF (termed "NBS positive CF"). Clinical outcomes were compared. Fourteen of 29 (48%, 95% CI 0.3-0.66) patients with intermediate sweat chloride value evolved to a diagnosis of CF and were matched with 28 NBS positive patients with CF. Delayed CF had less pancreatic insufficiency (OR 0.06, 95% CI 0.01-0.44, P = .006), less colonization with nonmucoid Pseudomonas aeruginosa (OR 0.04, 95% CI 0.01-0.38, P = .005), milder obstructive lung disease (forced expiratory volume in 1 second/forced vital capacity ratio), and overall disease severity (Shwachman scores) at 10 years (mean difference 5.93, 95% CI 0.39-11.46, P = .04; mean difference 4.72, 95% CI 0.9-8.53, P = .015, respectively). Nutritional outcomes were better at 2 years for delayed CF but did not persist to later ages. In this cohort, approximately one-half of infants with intermediate sweat chloride value were later diagnosed with CF. The clinical course of delayed CF was milder in some aspects compared with NBS positive CF. These results emphasize the importance of ongoing follow-up of infants with intermediate sweat chloride values. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  11. Resistance training for hot flushes in postmenopausal women: Randomized controlled trial protocol.

    Science.gov (United States)

    Berin, Emilia; Hammar, Mats L; Lindblom, Hanna; Lindh-Åstrand, Lotta; Spetz Holm, Anna-Clara E

    2016-03-01

    Hot flushes and night sweats affect 75% of all women after menopause and is a common reason for decreased quality of life in mid-aged women. Hormone therapy is effective in ameliorating symptoms but cannot be used by all women due to contraindications and side effects. Engagement in regular exercise is associated with fewer hot flushes in observational studies, but aerobic exercise has not proven effective in randomized controlled trials. It remains to be determined whether resistance training is effective in reducing hot flushes and improves quality of life in symptomatic postmenopausal women. The aim of this study is to investigate the effect of standardized resistance training on hot flushes and other health parameters in postmenopausal women. This is an open, parallel-group, randomized controlled intervention study conducted in Linköping, Sweden. Sixty symptomatic and sedentary postmenopausal women with a mean of at least four moderate to severe hot flushes per day or 28 per week will be randomized to an exercise intervention or unchanged physical activity (control group). The intervention consists of 15 weeks of standardized resistance training performed three times a week under supervision of a physiotherapist. The primary outcome is hot flush frequency assessed by self-reported hot flush diaries, and the difference in change from baseline to week 15 will be compared between the intervention group and the control group. The intention is that this trial will contribute to the evidence base regarding effective treatment for hot flushes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Acupuncture as Treatment of Hot Flashes and the Possible Role of Calcitonin Gene-Related Peptide

    Directory of Open Access Journals (Sweden)

    Anna-Clara E. Spetz Holm

    2012-01-01

    Full Text Available The mechanisms behind hot flashes in menopausal women are not fully understood. The flashes in women are probably preceded by and actually initiated by a sudden downward shift in the set point for the core body temperature in the thermoregulatory center that is affected by sex steroids, β-endorphins, and other central neurotransmitters. Treatments that influence these factors may be expected to reduce hot flashes. Since therapy with sex steroids for hot flashes has appeared to cause a number of side effects and risks and women with hot flashes and breast cancer as well as men with prostate cancer and hot flashes are prevented from sex steroid therapy there is a great need for alternative therapies. Acupuncture affecting the opioid system has been suggested as an alternative treatment option for hot flashes in menopausal women and castrated men. The heat loss during hot flashes may be mediated by the potent vasodilator and sweat gland activator calcitonin gene-related peptide (CGRP the concentration of which increases in plasma during flashes in menopausal women and, according to one study, in castrated men with flushes. There is also evidence for connections between the opioid system and the release of CGRP. In this paper we discuss acupuncture as a treatment alternative for hot flashes and the role of CGRP in this context.

  13. The mechanism of eccrine sweat pore plugging by aluminium salts using microfluidics combined with small angle X-ray scattering.

    Science.gov (United States)

    Bretagne, Alice; Cotot, Franck; Arnaud-Roux, Mireille; Sztucki, Michael; Cabane, Bernard; Galey, Jean-Baptiste

    2017-05-24

    Aluminium salts are widely used to control sweating for personal hygiene purposes. Their mechanism of action as antiperspirants was previously thought to be a superficial plugging of eccrine sweat pores by the aluminium hydroxide gel. Here we present a microfluidic T junction device that mimics sweat ducts, and is designed for the real time study of interactions between sweat and ACH (Aluminium Chloro Hydrate) under conditions that lead to plug formation. We used this device to image and measure the diffusion of aluminium polycationic species in sweat counter flow. We report the results of small angle X-ray scattering experiments performed to determine the structure and composition of the plug, using BSA (Bovine Serum Albumin) as a model of sweat proteins. Our results show that pore occlusion occurs as a result of the aggregation of sweat proteins by aluminium polycations. Mapping of the device shows that this aggregation is initiated in the T junction at the location where the flow of aluminium polycations joins the flow of BSA. The mechanism involves two stages: (1) a nucleation stage in which aggregates of protein and polycations bind to the wall of the sweat duct and form a tenuous membrane, which extends across the junction; (2) a growth stage in which this membrane collects proteins that are carried by hydrodynamic flow in the sweat channel and polycations that diffuse into this channel. These results could open up perspectives to find new antiperspirant agents with an improved efficacy.

  14. Latherin: a surfactant protein of horse sweat and saliva.

    Directory of Open Access Journals (Sweden)

    Rhona E McDonald

    2009-05-01

    Full Text Available Horses are unusual in producing protein-rich sweat for thermoregulation, a major component of which is latherin, a highly surface-active, non-glycosylated protein. The amino acid sequence of latherin, determined from cDNA analysis, is highly conserved across four geographically dispersed equid species (horse, zebra, onager, ass, and is similar to a family of proteins only found previously in the oral cavity and associated tissues of mammals. Latherin produces a significant reduction in water surface tension at low concentrations (< or = 1 mg ml(-1, and therefore probably acts as a wetting agent to facilitate evaporative cooling through a waterproofed pelt. Neutron reflection experiments indicate that this detergent-like activity is associated with the formation of a dense protein layer, about 10 A thick, at the air-water interface. However, biophysical characterization (circular dichroism, differential scanning calorimetry in solution shows that latherin behaves like a typical globular protein, although with unusual intrinsic fluorescence characteristics, suggesting that significant conformational change or unfolding of the protein is required for assembly of the air-water interfacial layer. RT-PCR screening revealed latherin transcripts in horse skin and salivary gland but in no other tissues. Recombinant latherin produced in bacteria was also found to be the target of IgE antibody from horse-allergic subjects. Equids therefore may have adapted an oral/salivary mucosal protein for two purposes peculiar to their lifestyle, namely their need for rapid and efficient heat dissipation and their specialisation for masticating and processing large quantities of dry food material.

  15. Baseline Evaluation With a Sweating Thermal Manikin of Personal Protective Ensembles Recommended for Use in West Africa.

    Science.gov (United States)

    Coca, Aitor; DiLeo, Travis; Kim, Jung-Hyun; Roberge, Raymond; Shaffer, Ronald

    2015-10-01

    Experience with the use of personal protective equipment (PPE) ensembles by health care workers responding to the Ebola outbreak in the hot, humid conditions of West Africa has prompted reports of significant issues with heat stress that has resulted in shortened work periods. A sweating thermal manikin was used to ascertain the time to achievement of a critical core temperature of 39 °C while wearing 4 different PPE ensembles similar to those recommended by the World Health Organization and Médecins Sans Frontières (Doctors Without Borders) at 2 different ambient conditions (32 °C/92% relative humidity and 26 °C/80% relative humidity) compared with a control ensemble. PPE ensembles that utilized coveralls with moderate to high degrees of impermeability attained the critical core temperature in significantly shorter times than did other ensembles. Encapsulation of the head and neck region resulted in higher model-predicted subjective impressions of heat sensation. To maximize work capacity and to protect health care workers in the challenging ambient conditions of West Africa, consideration should be given to adjustment of work and rest schedules, improvement of PPE (e.g., using less impermeable and more breathable fabrics that provide the same protection), and the possible use of cooling devices worn simultaneously with PPE.

  16. Skin pretreatment with microneedles prior to pilocarpine iontophoresis increases sweat production.

    Science.gov (United States)

    Wing, David; Prausnitz, Mark R; Buono, Michael J

    2013-11-01

    Collection of sweat via pilocarpine iontophoresis is commonly used to diagnose cystic fibrosis (CF), with thousands of tests performed each day. The main source of resistance to the passage of pilocarpine ions to the sweat glands is the electrical resistance of the stratum corneum. It was hypothesized that pretreating the skin with 0·5 mm-long microneedles would significantly decrease this resistance, thus increasing pilocarpine's permeation into the skin. Improved permeation should result in significantly reduced time to sweat initiation, time to collection of a clinically meaningful amount of sweat, and increased total amount of sweat produced in 15 min. Subjects (n = 12) had two 5 cm(2) areas on the forearm measured, marked and randomized to experimental (microneedles + iontophoresis) or control (iontophoresis alone). Microneedle pretreatment was conducted using a 35-needle microneedle stamp in a manner that 20 applications completely covered the 5 cm(2) treatment area. This was repeated five times for a total of 100 applications. Both experimental and control sites were placed under iontophoresis (1·5 mA) for 5 min. Microneedle pretreatment significantly decreased mean skin resistance (260 ± 27 kΩ versus 160 ± 19 kΩ, P = 0·006), while significantly increasing mean sweat rate (0·76 ± 0·35 versus 0·54 ± 0·19 μl cm(2) min(-1) , P = 0·007). No significant difference was found concerning pain (P = 0·059), number of active sweat glands (P = 0·627) or the osmolality of the collected sweat (P = 0·636). The results of this study suggest that microneedle pretreatment prior to pilocarpine iontophoresis significantly increases sweat production. Such results have the potential to improve the methodology currently used to diagnose cystic fibrosis and, more broadly, to administer drugs via the skin. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  17. Growth Plate Injuries

    Science.gov (United States)

    ... plate injuries includes: Falling down. Competitive sports (like football). Recreational activities. Sometimes growth plate injuries happen when ... knee. For More Info U.S. Food and Drug Administration Toll free: 888-INFO-FDA (888-463-6332) ...

  18. Create Your Plate

    Science.gov (United States)

    ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... of Diabetes Research & Practice Home We Are Research Leaders World's Largest Diabetes Meeting Recent Advances Type 1 ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but changes the portion sizes so you are getting larger ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... this interactive tool. The healthy meal combinations are endless! Ready to try it at home? Just follow ... non-starchy vegetables and that your options are endless. Create Your Plate! Click on the plate sections ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... treatments for those living with diabetes. Other Ways to Give Become a Member Vehicle Donation Planned Giving ... Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective for ...

  5. Sweat osmolarity shows intra-animal regional variation in the horse.

    Science.gov (United States)

    Potts, Samantha; Thatcher, Rhys; Jones, Arwel W; Warren, Lori K; Tenbroeck, Saundra H; Nottage, Florence; McEwan, Neil R

    2015-10-01

    Sweating is important in regulating body temperature but can be a source of loss of both fluids and electrolytes. Although the process has been studied in horses, the variation in sweat osmolarity across the body has not. This work describes an investigation to determine if there is regional variation in the osmolarity of sweat across different anatomical regions of the horse. Ten horses were used in the study and were animals either stabled for riding lessons or had livery on-site. Sweat samples were collected from five regions on each horse following exercise and the osmolarity measurements were made using an Osmomat 030 (Gonotec, Berlin, Germany). Values were analysed by paired t-tests and analysis of variance. Samples from the back and ears had statistically (P sweat collected from the horse's back. The current work demonstrates that these values are probably an underestimation of electrolyte loss, which may have implications for the composition and administration of rehydration compounds. © 2015 ESVD and ACVD.

  6. Correlation of sweat chloride and percent predicted FEV1in cystic fibrosis patients treated with ivacaftor.

    Science.gov (United States)

    Fidler, Meredith C; Beusmans, Jack; Panorchan, Paul; Van Goor, Fredrick

    2017-01-01

    Ivacaftor, a CFTR potentiator that enhances chloride transport by acting directly on CFTR to increase its channel gating activity, has been evaluated in patients with different CFTR mutations. Several previous analyses have reported no statistical correlation between change from baseline in ppFEV 1 and reduction in sweat chloride levels for individuals treated with ivacaftor. The objective of the post hoc analysis described here was to expand upon previous analyses and evaluate the correlation between sweat chloride levels and absolute ppFEV 1 changes across multiple cohorts of patients with different CF-causing mutations who were treated with ivacaftor. The goal of the analysis was to help define the potential value of sweat chloride as a pharmacodynamic biomarker for use in CFTR modulator trials. For any given study, reductions in sweat chloride levels and improvements in absolute ppFEV 1 were not correlated for individual patients. However, when the data from all studies were combined, a statistically significant correlation between sweat chloride levels and ppFEV 1 changes was observed (psweat chloride level changes in response to potentiation of the CFTR protein by ivacaftor appear to be a predictive pharmacodynamic biomarker of lung function changes on a population basis but are unsuitable for the prediction of treatment benefits for individuals. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Feasibility and normal values of an integrated conductivity (Nanoduct™) sweat test system in healthy newborns.

    Science.gov (United States)

    Kuehni, Claudia E; Schindler, Matthias; Mazur, Agnieszka; Malzacher, Andreas; Hornung, René; Barben, Juerg

    2017-07-01

    Nanoduct™ is a simple and practical sweat analysis system measuring conductivity in situ. It requires only three microlitres of sweat, making it especially applicable to newborns. We measured conductivity in 260 healthy term infants at the age of four days, and again at four weeks to determine the proportion of successful tests, test duration, and normal values for sweat conductivity in newborns. Sufficient sweat was collected in 159/260 of four-day olds (61%), and in 225/239 of four-week olds (94%). Mean (sd) test duration was 27 (5) and 25 (5) min. Mean (sd, range) conductivity was 53mmol/l (16, 8-114) at age four days, and 36 (9, 12-64) at four weeks. Determination of sweat conductivity using Nanoduct™ cannot be recommended for four-day old newborns. However, at the age of four weeks the success rate is high (94%), and conductivity values at that age are comparable to older healthy children. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  8. Realistic Facial Expression of Virtual Human Based on Color, Sweat, and Tears Effects

    Directory of Open Access Journals (Sweden)

    Mohammed Hazim Alkawaz

    2014-01-01

    Full Text Available Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry and blushing (anger and happiness is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics.

  9. Realistic facial expression of virtual human based on color, sweat, and tears effects.

    Science.gov (United States)

    Alkawaz, Mohammed Hazim; Basori, Ahmad Hoirul; Mohamad, Dzulkifli; Mohamed, Farhan

    2014-01-01

    Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry) and blushing (anger and happiness) is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs) of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH) methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics.

  10. Realistic Facial Expression of Virtual Human Based on Color, Sweat, and Tears Effects

    Science.gov (United States)

    Alkawaz, Mohammed Hazim; Basori, Ahmad Hoirul; Mohamad, Dzulkifli; Mohamed, Farhan

    2014-01-01

    Generating extreme appearances such as scared awaiting sweating while happy fit for tears (cry) and blushing (anger and happiness) is the key issue in achieving the high quality facial animation. The effects of sweat, tears, and colors are integrated into a single animation model to create realistic facial expressions of 3D avatar. The physical properties of muscles, emotions, or the fluid properties with sweating and tears initiators are incorporated. The action units (AUs) of facial action coding system are merged with autonomous AUs to create expressions including sadness, anger with blushing, happiness with blushing, and fear. Fluid effects such as sweat and tears are simulated using the particle system and smoothed-particle hydrodynamics (SPH) methods which are combined with facial animation technique to produce complex facial expressions. The effects of oxygenation of the facial skin color appearance are measured using the pulse oximeter system and the 3D skin analyzer. The result shows that virtual human facial expression is enhanced by mimicking actual sweating and tears simulations for all extreme expressions. The proposed method has contribution towards the development of facial animation industry and game as well as computer graphics. PMID:25136663

  11. Accelerated plate tectonics.

    Science.gov (United States)

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Share: Print Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy veggies ...

  13. In Vivo Readout of CFTR Function: Ratiometric Measurement of CFTR-Dependent Secretion by Individual, Identifiable Human Sweat Glands

    Science.gov (United States)

    Wine, Jeffrey J.; Char, Jessica E.; Chen, Jonathan; Cho, Hyung-ju; Dunn, Colleen; Frisbee, Eric; Joo, Nam Soo; Milla, Carlos; Modlin, Sara E.; Park, Il-Ho; Thomas, Ewart A. C.; Tran, Kim V.; Verma, Rohan; Wolfe, Marlene H.

    2013-01-01

    To assess CFTR function in vivo, we developed a bioassay that monitors and compares CFTR-dependent and CFTR-independent sweat secretion in parallel for multiple (∼50) individual, identified glands in each subject. Sweating was stimulated by intradermally injected agonists and quantified by optically measuring spherical sweat bubbles in an oil-layer that contained dispersed, water soluble dye particles that partitioned into the sweat bubbles, making them highly visible. CFTR-independent secretion (M-sweat) was stimulated with methacholine, which binds to muscarinic receptors and elevates cytosolic calcium. CFTR-dependent secretion (C-sweat) was stimulated with a β-adrenergic cocktail that elevates cytosolic cAMP while blocking muscarinic receptors. A C-sweat/M-sweat ratio was determined on a gland-by-gland basis to compensate for differences unrelated to CFTR function, such as gland size. The average ratio provides an approximately linear readout of CFTR function: the heterozygote ratio is ∼0.5 the control ratio and for CF subjects the ratio is zero. During assay development, we measured C/M ratios in 6 healthy controls, 4 CF heterozygotes, 18 CF subjects and 4 subjects with ‘CFTR-related’ conditions. The assay discriminated all groups clearly. It also revealed consistent differences in the C/M ratio among subjects within groups. We hypothesize that these differences reflect, at least in part, levels of CFTR expression, which are known to vary widely. When C-sweat rates become very low the C/M ratio also tended to decrease; we hypothesize that this nonlinearity reflects ductal fluid absorption. We also discovered that M-sweating potentiates the subsequent C-sweat response. We then used potentiation as a surrogate for drugs that can increase CFTR-dependent secretion. This bioassay provides an additional method for assessing CFTR function in vivo, and is well suited for within-subject tests of systemic, CFTR-directed therapeutics. PMID:24204751

  14. Exercise-induced trace mineral element concentration in regional versus whole-body wash-down sweat.

    Science.gov (United States)

    Baker, Lindsay B; Stofan, John R; Lukaski, Henry C; Horswill, Craig A

    2011-06-01

    Simultaneous whole-body wash-down (WBW) and regional skin surface sweat collections were completed to compare regional patch and WBW sweat calcium (Ca), magnesium (Mg), copper (Cu), manganese (Mn), iron (Fe), and zinc (Zn) concentrations. Athletes (4 men, 4 women) cycled in a plastic open-air chamber for 90 min in the heat. Before exercise, the subjects and cycle ergometer (covered in plastic) were washed with deionized water. After the onset of sweating, sterile patches were attached to the forearm, back, chest, forehead, and thigh and removed on saturation. After exercise, the subjects and cycle ergometer were washed with 5 L of 15-mM ammonium sulfate solution to collect all sweat minerals and determine the volume of unevaporated sweat. Control trials were performed to measure mineral contamination in regional and WBW methods. Because background contamination in the collection system was high for WBW Mn, Fe, and Zn, method comparisons were not made for these minerals. After correction for minimal background contamination, WBW sweat [Ca], [Mg], and [Cu] were 44.6 ± 20.0, 9.8 ± 4.8, and 0.125 ± 0.069 mg/L, respectively, and 5-site regional (weighted for local sweat rate and body surface area) sweat [Ca], [Mg], and [Cu] were 59.0 ± 15.9, 14.5 ± 4.8, and 0.166 ± 0.031 mg/L, respectively. Five-site regional [Ca], [Mg], and [Cu] overestimated WBW by 32%, 48%, and 33%, respectively. No individual regional patch site or 5-site regional was significantly correlated with WBW sweat [Ca] (r = -.21, p = .65), [Mg] (r = .49, p = .33), or [Cu] (r = .17, p = .74). In conclusion, regional sweat [Ca], [Mg], and [Cu] are not accurate surrogates for or significantly correlated with WBW sweat composition.

  15. Eccrine sweat gland anatomy in cockayne syndrome: a possible diagnostic aid.

    Science.gov (United States)

    Landing, B H; Sugarman, G; Dixon, L G

    1983-01-01

    Cockayne syndrome is an autosomal recessive disease, which includes as major features motor and mental retardation (beginning in the second year), microcephaly, ataxia, retinal degeneration and pigmentation, cataracts, progeroid features, intracranial calcification, hypogonadism, and growth retardation. Many other diseases have some of these features, so that diagnosis of Cockayne syndrome can be difficult, especially in younger children. Eccrine sweat glands were microdissected from autopsy or biopsy specimens from patients with Cockayne syndrome, and mean values for duct length, secretory coil volume, ratio of coil volume to duct length, and axis ratio of the secretory coil were determined. In comparison with values for eccrine glands of patients with no known genetic or chromosomal disease, eccrine glands in Cockayne syndrome are abnormally small for age. Whether other diseases with various similarities to Cockayne syndrome produce similar growth abnormality of eccrine sweat glands is not known, but determination of sweat gland size may provide data suggesting or supporting the diagnosis of Cockayne syndrome.

  16. Amino acid composition, including key derivatives of eccrine sweat: potential biomarkers of certain atopic skin conditions.

    Science.gov (United States)

    Mark, Harker; Harding, Clive R

    2013-04-01

    The free amino acid (AA) composition of eccrine sweat is different from other biological fluids, for reasons which are not properly understood. We undertook the detailed analysis of the AA composition of freshly isolated pure human eccrine sweat, including some of the key derivatives of AA metabolism, to better understand the key biological mechanisms governing its composition. Eccrine sweat was collected from the axillae of 12 healthy subjects immediately upon formation. Free AA analysis was performed using an automatic AA analyser after ninhydrin derivatization. Pyrrolidine-5-carboxylic acid (PCA) and urocanic acid (UCA) levels were determined using GC/MS. The free AA composition of sweat was dominated by the presence of serine accounting for just over one-fifth of the total free AA composition. Glycine was the next most abundant followed by PCA, alanine, citrulline and threonine, respectively. The data obtained indicate that the AA content of sweat bears a remarkable similarity to the AA composition of the epidermal protein profilaggrin. This protein is the key source of free AAs and their derivatives that form a major part of the natural moisturizing factor (NMF) within the stratum corneum (SC) and plays a major role in maintaining the barrier integrity of human skin. As perturbations in the production of NMF can lead to abnormal barrier function and can arise as a consequence of filaggrin genotype, we propose the quantification of AAs in sweat may serve as a non-invasive diagnostic biomarker for certain atopic skin conditions, that is, atopic dermatitis (AD). © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  17. Role of Sweat in Accumulation of Orally Administered Griseofulvin in Skin

    Science.gov (United States)

    Shah, Vinod P.; Epstein, William L.; Riegelman, Sidney

    1974-01-01

    Griseofulvin, an orally effective antimicrobial agent, appears in the stratum corneum within 4-8 h after oral administration. Griseofulvin distribution was found to be highest in the outermost layers of the stratum corneum (level I, 20.8±1.5 ng/mg) and lowest inside (level II, 10.0±1.5; level III, 7.5±2.2 ng/mg). In order to study the precise mechanism of griseofulvin transfer to stratum corneum, the role of sweat in the accumulation of griseofulvin was considered. Heat-induced total body sweating decreased the mean stratum corneum concentration of griseofulvin by 55%, and 200-300 ng of griseofulvin accumulated per ml of sweat. A silicone hydrophobic resin was used to differentiate between “wash-off” and carrier properties of sweat for griseofulvin. Prevention of transepidermal water and sweat loss by (a) topical application of formaldehyde-releasing cream to one palm, (b) occlusion by a 2 × 2-cm patch on one arm, and (c) wearing a rubber glove for 24 h, showed a lower griseofulvin concentration when compared to control areas in the same subjects. The results of the gloved hand experiment show that a complete equilibrium is established at all three levels of stratum corneum, thereby removing the reversed gradient. These results support the hypothesis that a “wick effect” is responsible for the observed reversed drug gradient within the stratum corneum. The results of the experiments suggest that sweat and transepidermal fluid loss play an important role in griseofulvin transfer in stratum corneum. PMID:4830229

  18. Geologically current plate motions

    Science.gov (United States)

    DeMets, Charles; Gordon, Richard G.; Argus, Donald F.

    2010-04-01

    We describe best-fitting angular velocities and MORVEL, a new closure-enforced set of angular velocities for the geologically current motions of 25 tectonic plates that collectively occupy 97 per cent of Earth's surface. Seafloor spreading rates and fault azimuths are used to determine the motions of 19 plates bordered by mid-ocean ridges, including all the major plates. Six smaller plates with little or no connection to the mid-ocean ridges are linked to MORVEL with GPS station velocities and azimuthal data. By design, almost no kinematic information is exchanged between the geologically determined and geodetically constrained subsets of the global circuit-MORVEL thus averages motion over geological intervals for all the major plates. Plate geometry changes relative to NUVEL-1A include the incorporation of Nubia, Lwandle and Somalia plates for the former Africa plate, Capricorn, Australia and Macquarie plates for the former Australia plate, and Sur and South America plates for the former South America plate. MORVEL also includes Amur, Philippine Sea, Sundaland and Yangtze plates, making it more useful than NUVEL-1A for studies of deformation in Asia and the western Pacific. Seafloor spreading rates are estimated over the past 0.78 Myr for intermediate and fast spreading centres and since 3.16 Ma for slow and ultraslow spreading centres. Rates are adjusted downward by 0.6-2.6mmyr-1 to compensate for the several kilometre width of magnetic reversal zones. Nearly all the NUVEL-1A angular velocities differ significantly from the MORVEL angular velocities. The many new data, revised plate geometries, and correction for outward displacement thus significantly modify our knowledge of geologically current plate motions. MORVEL indicates significantly slower 0.78-Myr-average motion across the Nazca-Antarctic and Nazca-Pacific boundaries than does NUVEL-1A, consistent with a progressive slowdown in the eastward component of Nazca plate motion since 3.16 Ma. It also

  19. Hot flushes still occur in a population of 85-year-old Swedish women.

    Science.gov (United States)

    Vikström, J; Spetz Holm, A-C; Sydsjö, G; Marcusson, J; Wressle, E; Hammar, M

    2013-08-01

    Hot flushes and night sweats often cause discomfort and may negatively affect sleep and quality of life. Studies have shown that menopausal symptoms, like hot flushes, may persist for up to 20 years after the menopausal transition, but there are no published studies regarding the occurrence of hot flushes among women older than 80 years. The aim of this study is to determine the prevalence of hot flushes in 85-year-old women. All 85-year old women living in Linköping municipality in 2007 (n = 415) received a postal questionnaire. The majority, 74% (n = 307), answered the questionnaire and 47% (n = 194) agreed to visit the Department of Geriatric Medicine; during this visit questions regarding hot flushes and use of hormone therapy were asked. About 16% (n = 29) of the women experienced hot flushes during the day and/or during the night and 6.5% (n = 12) of the women were currently using hormone therapy. Almost 10% (n = 17) of all responding women were very to moderately distressed by their hot flushes. Our results confirm and extend previous knowledge based on studies of younger postmenopausal women in showing that menopausal symptoms still occur in elderly women. We found that, while the prevalence of menopausal symptoms decreases with age, these symptoms are still experienced by some 85-year-old women.

  20. Clinical hypnosis in the treatment of postmenopausal hot flashes: a randomized controlled trial.

    Science.gov (United States)

    Elkins, Gary R; Fisher, William I; Johnson, Aimee K; Carpenter, Janet S; Keith, Timothy Z

    2013-03-01

    The use of estrogen and progesterone to manage vasomotor symptoms (ie, hot flashes and night sweats) has declined because of concerns about their risks, and there is an increased interest in alternate, effective, and low-risk treatments. This study reports the results of a randomized controlled trial of clinical hypnosis for treating vasomotor symptoms among postmenopausal women. This is a randomized, single-blind, controlled, clinical trial involving 187 postmenopausal women reporting a minimum of seven hot flashes per day (or at least 50 hot flashes a week) at baseline between December 2008 and April 2012. Eligible participants received five weekly sessions of either clinical hypnosis or structured-attention control. Primary outcomes were hot flash frequency (subjectively and physiologically recorded) and hot flash score assessed by daily diaries on weeks 2 to 6 and week 12. Secondary outcomes included measures of hot flash-related daily interference, sleep quality, and treatment satisfaction. In a modified intent-to-treat analysis that included all randomized participants who provided data, reported subjective hot flash frequency from baseline to week 12 showed a mean reduction of 55.82 (74.16%) hot flashes for the clinical hypnosis intervention versus a mean reduction of 12.89 (17.13%) hot flashes for controls (P hypnosis intervention as compared with 3.53 (15.38%) for controls (P hypnosis and 0.88 (9.94%) for controls (P hypnosis results in significant reductions in self-reported and physiologically measured hot flashes and hot flash scores in postmenopausal women.

  1. Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening

    NARCIS (Netherlands)

    Vernooij-van Langen, Annette; Dompeling, Edward; Yntema, Jan-Bart; Arets, HGM|info:eu-repo/dai/nl/244205698; Tiddens, Harm; Loeber, Gerard; Dankert-Roelse, Jeannette

    After a positive newborn screening test for cystic fibrosis (CF), a sweat test is performed to confirm the diagnosis. The success rate of the generally acknowledged methods (Macroduct/Gibson and Cooke) in newborns varies between 73 and 99 %. The Nanoduct sweat test system is easier to perform and

  2. Highly abundant defense proteins in human sweat as revealed by targeted proteomics and label free quantification mass spectrometry

    Science.gov (United States)

    Csősz, Éva; Emri, Gabriella; Kalló, Gergő; Tsaprailis, George; Tőzsér, József

    2015-01-01

    BACKGROUND The healthy human skin with its effective antimicrobial defense system forms an efficient barrier against invading pathogens. There is evidence suggesting that the composition of this chemical barrier varies between diseases, making the easily-collected sweat an ideal candidate for biomarker discoveries. OBJECTIVE Our aim was to provide information about the normal composition of the sweat, and to study the chemical barrier found at the surface of skin. METHODS Sweat samples from healthy individuals were collected during sauna bathing, and the global protein panel was analyzed by label-free mass spectrometry. SRM-based targeted proteomic methods were designed and stable isotope labeled reference peptides were used for method validation. RESULTS 95 sweat proteins were identified, 20 of them were novel proteins. It was shown that dermcidin is the most abundant sweat protein, and along with apolipoprotein D, clusterin, prolactin inducible protein and serum albumin, they make up 91% of secreted sweat proteins. The roles of these highly abundant proteins were reviewed; all of which have protective functions, highlighting the importance of sweat glands in composing the first line of innate immune defense system, and maintaining the epidermal barrier integrity. CONCLUSION Our findings in regards to the proteins forming the chemical barrier of the skin as determined by label free quantification and targeted proteomics methods are in accordance with previous studies, and can be further used as a starting point for non-invasive sweat biomarker research. PMID:26307449

  3. 3D bioprinted extracellular matrix mimics facilitate directed differentiation of epithelial progenitors for sweat gland regeneration.

    Science.gov (United States)

    Huang, Sha; Yao, Bin; Xie, Jiangfan; Fu, Xiaobing

    2016-03-01

    Sweat glands perform a vital thermoregulatory function in mammals. Like other skin appendages, they originate from epidermal progenitors. However, they have low regenerative potential in response to injury, and whether adult epidermal progenitors could be specified to differentiate to a sweat gland cell lineage remains largely unexplored. We used bioprinting technology to create a functional in vitro cell-laden 3D extracellular matrix mimics (3D-ECM) with composite hydrogels based on gelatin and sodium alginate because of chemical and structural similarity to ECM components. To achieve specific cell differentiation, mouse plantar dermis and epidermal growth factor were synchronously incorporated into the 3D-ECM mimics to create an inductive niche for epidermal progenitor cells obtained from mice. The biological 3D construct could maintain cell viability, thereby facilitating cell spreading and matrix formation. In vitro data by immunofluorescence and gene expression assay of key cell-surface markers demonstrated that the bioprinted 3D-ECM could effectively create a restrictive niche for epidermal progenitors that ensures unilateral differentiation into sweat gland cells. Furthermore, direct delivery of bioprinted 3D-ECM into burned paws of mice resulted in functional restoration of sweat glands. This study represents the rational design to enhance the specific differentiation of epidermal lineages using 3D bioprinting and may have clinical and translational implications in regenerating sweat glands. Sweat gland regeneration after injury is of clinical importance but remains largely unsolved because of low regenerative potential and lack of a definite niche. Some studies have shown sweat gland regeneration with gene-based interventions or cell-based induction via embryonic components, but translation to clinic is challenging. The novelty and significance of the work lies in the fact that we design a 3D bioprinted extracellular matrix that provides the spatial

  4. Real-time sweat analysis: Concept and development of an autonomous wearable micro-fluidic platform

    OpenAIRE

    Curto, Vincenzo F.; Coyle, Shirley; Byrne, Robert; Diamond, Dermot; Benito-Lopez, Fernando

    2011-01-01

    In this work the development of an autonomous, robust and wearable micro-fluidic platform capable of performing on-line analysis of pH in sweat is discussed. Through the means of an optical detection system based on a surface mount light emitting diode (smLED) and a photodiode as a detector, a wearable system was achieved in which realtime monitoring of sweat pH can be performed during sport activity. We show how through systems engineering, integrating miniaturised electrical com...

  5. The Effect of Varying the Composition of Fingerprint Sweat Deposits on the Corrosion of Brass and Fingerprint Visibility.

    Science.gov (United States)

    Cooper-Dunn, Alice; Jones, Owen; Bond, John W

    2017-09-01

    Corrosion of α-phase brass by sebaceous sweat fingerprint deposits produced identifiable impressions in a majority of samples (n = 40) 4 days after deposition. Combining sebaceous with eccrine sweat yielded a greater percentage of identifiable fingerprint deposits, although this increase was not statistically significant. Production of identifiable fingerprints from eccrine sweat deposits was dependent on the sampling time of year with deposits taken during summer months giving similar percentages of identifiable fingerprints to sebaceous deposits. A statistically significant positive correlation was found between elapsed days after deposition and identifiable eccrine (ρ = 0.787, p sweat deposits was statistically significant compared to winter eccrine deposits (p sweat. © 2017 American Academy of Forensic Sciences.

  6. Normal sweat secretion despite impaired growth hormone-insulin-like growth factor-I axis in obese subjects

    DEFF Research Database (Denmark)

    Rasmussen, M H; Juul, Anders; Main, Katharina M

    2011-01-01

    and after weight loss. Sixteen severely obese women (BMI, 40.6 ± 1.1 kg/m(2)) were investigated before and after a diet-induced weight loss. Sixteen age-matched nonobese women served as controls. The obese subjects presented the characteristic decreased GH release, hyperinsulinaemia, increased FFA levels......, and impaired insulin sensitivity, which all were normalised after diet-induced weight loss of 30 ± 5 kg. Sweat secretion rates were similar comparing obese and nonobese subjects (78 ± 10 versus 82 ± 9 mg/30 minutes) and sweat secretion did not change after a diet-induced weight loss in obese subjects. We......Adults with GH deficiency are known to exhibit reduced sweating. Whether sweating capacity is impacted in obese subjects with impaired GH secretion have not previously been investigated. The main objective was to investigate sweat secretion rate and the GH-IGF-I axis in obese subjects before...

  7. Rice-based electrolyte drinks more effective than water in replacing sweat losses during hot weather training and operations.

    Science.gov (United States)

    Gerold, Kevin B; Greenough, William B

    2013-01-01

    Heat-related injury presents significant threats to the health and operational effectiveness of Soldiers and military operations. In 2012, active component, U.S. Armed Forces experienced 365 incident cases of heat stroke and 2,257 incident cases of ?other heat injury.? Most of these occurred among recruit and enlisted personnel and most were under the age of 30. In conditioned military personnel, a rice-based oral rehydration solution was superior to water alone at maintaining body weight and, by inference, enabled Soldiers to better maintain their the state of hydration during prolonged exercise in high ambient temperatures. In view of the health risks associated with dehydration and their effects on training and operations, this study suggests that the consumption of beverages containing electrolytes and a rice-based carbohydrate is superior to the consumption of water alone in preventing dehydration and heat related illness. 2013.

  8. Sauna, sweat and science - quantifying the proportion of condensation water versus sweat using a stable water isotope ((2)H/(1)H and (18)O/(16)O) tracer experiment.

    Science.gov (United States)

    Zech, Michael; Bösel, Stefanie; Tuthorn, Mario; Benesch, Marianne; Dubbert, Maren; Cuntz, Matthias; Glaser, Bruno

    2015-01-01

    Most visitors of a sauna appreciate the heat pulse that is perceived when water is poured on the stones of a sauna stove. However, probably only few bathers are aware that this pleasant heat pulse is caused by latent heat being released onto our skin due to condensation of water vapour. In order to quantify the proportion of condensation water versus sweat to dripping water of test persons we conducted sauna experiments using isotopically labelled (δ(18)O and δ(2)H) thrown water as tracer. This allows differentiating between 'pure sweat' and 'condensation water'. Two ways of isotope mass balance calculations were applied and yielded similar results for both water isotopes. Accordingly, condensation contributed considerably to dripping water with mean proportions of 52 ± 12 and 54 ± 7% in a sauna experiment in winter semester 2011/12 and 30 ± 13 and 33 ± 6% in a sauna experiment in winter semester 2012/13, respectively, depending on the way of calculating the isotope mass balance. It can be concluded from the results of our dual isotope labelling sauna experiment that it is not all about sweat in the sauna.

  9. Store-operated Ca2+ entry regulates Ca2+-activated chloride channels and eccrine sweat gland function.

    Science.gov (United States)

    Concepcion, Axel R; Vaeth, Martin; Wagner, Larry E; Eckstein, Miriam; Hecht, Lee; Yang, Jun; Crottes, David; Seidl, Maximilian; Shin, Hyosup P; Weidinger, Carl; Cameron, Scott; Turvey, Stuart E; Issekutz, Thomas; Meyts, Isabelle; Lacruz, Rodrigo S; Cuk, Mario; Yule, David I; Feske, Stefan

    2016-11-01

    Eccrine sweat glands are essential for sweating and thermoregulation in humans. Loss-of-function mutations in the Ca2+ release-activated Ca2+ (CRAC) channel genes ORAI1 and STIM1 abolish store-operated Ca2+ entry (SOCE), and patients with these CRAC channel mutations suffer from anhidrosis and hyperthermia at high ambient temperatures. Here we have shown that CRAC channel-deficient patients and mice with ectodermal tissue-specific deletion of Orai1 (Orai1K14Cre) or Stim1 and Stim2 (Stim1/2K14Cre) failed to sweat despite normal sweat gland development. SOCE was absent in agonist-stimulated sweat glands from Orai1K14Cre and Stim1/2K14Cre mice and human sweat gland cells lacking ORAI1 or STIM1 expression. In Orai1K14Cre mice, abolishment of SOCE was associated with impaired chloride secretion by primary murine sweat glands. In human sweat gland cells, SOCE mediated by ORAI1 was necessary for agonist-induced chloride secretion and activation of the Ca2+-activated chloride channel (CaCC) anoctamin 1 (ANO1, also known as TMEM16A). By contrast, expression of TMEM16A, the water channel aquaporin 5 (AQP5), and other regulators of sweat gland function was normal in the absence of SOCE. Our findings demonstrate that Ca2+ influx via store-operated CRAC channels is essential for CaCC activation, chloride secretion, and sweat production in humans and mice.

  10. A novel TMEM16A splice variant lacking the dimerization domain contributes to calcium-activated chloride secretion in human sweat gland epithelial cells.

    Science.gov (United States)

    Ertongur-Fauth, Torsten; Hochheimer, Andreas; Buescher, Joerg Martin; Rapprich, Stefan; Krohn, Michael

    2014-11-01

    Sweating is an important physiological process to regulate body temperature in humans, and various disorders are associated with dysregulated sweat formation. Primary sweat secretion in human eccrine sweat glands involves Ca(2+) -activated Cl(-) channels (CaCC). Recently, members of the TMEM16 family were identified as CaCCs in various secretory epithelia; however, their molecular identity in sweat glands remained elusive. Here, we investigated the function of TMEM16A in sweat glands. Gene expression analysis revealed that TMEM16A is expressed in human NCL-SG3 sweat gland cells as well as in isolated human eccrine sweat gland biopsy samples. Sweat gland cells express several previously described TMEM16A splice variants, as well as one novel splice variant, TMEM16A(acΔe3) lacking the TMEM16A-dimerization domain. Chloride flux assays using halide-sensitive YFP revealed that TMEM16A is functionally involved in Ca(2+) -dependent Cl(-) secretion in NCL-SG3 cells. Recombinant expression in NCL-SG3 cells showed that TMEM16A(acΔe3) is forming a functional CaCC, with basal and Ca(2+) -activated Cl(-) permeability distinct from canonical TMEM16A(ac). Our results suggest that various TMEM16A isoforms contribute to sweat gland-specific Cl(-) secretion providing opportunities to develop sweat gland-specific therapeutics for treatment of sweating disorders. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Hot-pressed geopolymer

    DEFF Research Database (Denmark)

    Ranjbar, Navid; Mehrali, Mohammad; Maheri, Mahmoud R.

    2017-01-01

    /FA, duration of hot-pressing and sodium concentration are studied. Together with detailed experimental studies, our results reveal that the most dominant factor is the induced pressure. The main results indicated that the highest compressive strength of the geopolymer (134 MPa) could be obtained by employing...... the hot pressing, temperature and duration of 41.4 MPa, 350 °C and 20 min, respectively. The microstructure of the hot-pressed specimens showed more developed geopolymer matrix compared with conventional ones leading to higher compressive strength in much shortest time. The improved mechanical properties...

  12. Biomonitoring and Elimination of Perfluorinated Compounds and Polychlorinated Biphenyls through Perspiration: Blood, Urine, and Sweat Study

    Science.gov (United States)

    Genuis, Stephen J.; Beesoon, Sanjay; Birkholz, Detlef

    2013-01-01

    Perfluorinated compounds (PFCs) are man-made organofluorine chemicals manufactured and marketed for their stain-resistant properties. Polychlorinated biphenyls (PCBs) are anthropogenic organochlorine compounds previously used in various industrial and chemical applications prior to being banned in the Western world in the 1970s. Both PFCs and PCBs are persistent contaminants within the human organism and both have been linked to adverse health sequelae. Data is lacking on effective means to facilitate clearance of PFCs and PCBs from the body. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for PFCs and PCBs using high performance liquid chromatography tandem mass spectrometry. Results. Some individual PCB congeners, but not all, were released into sweat at varying concentrations. None of the PFCs found in serum testing appeared to be excreted efficiently into perspiration. Conclusions. Induced perspiration may have some role in facilitating elimination of selected PCBs. Sweat analysis may be helpful in establishing the existence of some accrued PCBs in the human body. Sweating does not appear to facilitate clearance of accrued PFHxS (perfluorohexane sulfonate), PFOS (perfluorooctane sulfonate), or PFOA (perfluorooctanoic acid), the most common PFCs found in the human body. PMID:24083032

  13. Determination of silver nanoparticle release from antibacterial fabrics into artificial sweat

    Directory of Open Access Journals (Sweden)

    Kulthong Kornphimol

    2010-04-01

    Full Text Available Abstract Silver nanoparticles have been used in numerous commercial products, including textiles, to prevent bacterial growth. Meanwhile, there is increasing concern that exposure to these nanoparticles may cause potential adverse effects on humans as well as the environment. This study determined the quantity of silver released from commercially claimed nanosilver and laboratory-prepared silver coated fabrics into various formulations of artificial sweat, each made according to AATCC, ISO and EN standards. For each fabric sample, the initial amount of silver and the antibacterial properties against the model Gram-positive (S. aureus and Gram-negative (E. coli bacteria on each fabric was investigated. The results showed that silver was not detected in some commercial fabrics. Furthermore, antibacterial properties of the fabrics varied, ranging from 0% to greater than 99%. After incubation of the fabrics in artificial sweat, silver was released from the different fabrics to varying extents, ranging from 0 mg/kg to about 322 mg/kg of fabric weight. The quantity of silver released from the different fabrics was likely to be dependent on the amount of silver coating, the fabric quality and the artificial sweat formulations including its pH. This study is the unprecedented report on the release of silver nanoparticles from antibacterial fabrics into artificial sweat. This information might be useful to evaluate the potential human risk associated with the use of textiles containing silver nanoparticles.

  14. The Italian pilot external quality assessment program for cystic fibrosis sweat test.

    Science.gov (United States)

    Salvatore, Marco; Floridia, Giovanna; Amato, Annalisa; Censi, Federica; Carta, Claudio; de Stefano, Maria Chiara; Ferrari, Gianluca; Tosto, Fabrizio; Capoluongo, Ettore; Caruso, Ubaldo; Castaldo, Giuseppe; Cirilli, Natalia; Corbetta, Carlo; Padoan, Rita; Raia, Valeria; Taruscio, Domenica

    2016-05-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. In 2014 the Istituto Superiore di Sanità established the Italian pilot external quality assessment program for CF sweat test (IEQA-ST). Ten laboratories, included among the 33 Italian CF Referral Centers, were selected and enrolled on the basis of their attitude to perform sweat test (ST) analysis by using methods recommended by the Italian Guidelines. They received three different sweat-like samples (normal, borderline and pathologic chloride concentration), with mock clinical indications, for analysis according to routine procedures. Assessment, performed by a panel of experts, covered analytical performance, interpretation and reporting of results; categories of "poor" and "satisfactory" performance were not defined. All data were managed through a web utility. The program identified important areas of interest and, in some case, of concern. It is important to underline that results are referred to a small proportion, i.e. about 30%, of Italian laboratories performing CF ST in the context of the Referral Centers. Data collected highlight the importance of participation in EQA programs as it may improve laboratory/clinical performance; our study represents a model for the setting up of a large-scale EQA scheme for ST. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Sweating Rates of Dairy and Feedlot Cows in Stressful Thermal Environments

    Science.gov (United States)

    Sweating rates from heat-stressed dairy and feedlot cows were measured using a portable calorimeter. Measurements were made when cows were in shade and exposed to direct sunlight (120 to 1100 W/m2) under different air velocities (0.1 to 1.8 m/s). The effect of color of hair coat (black and white) on...

  16. Human communication of emotion via sweat : How specific is it? (abstract)

    NARCIS (Netherlands)

    Smeets, M.A.M.; Toet, A.; Duinkerken, R.; Groot, J. de; Kaldewaij, A.; Hout, M.A. van den; et al

    2011-01-01

    Females evaluate ambiguous facial expression – morphed between happy and fearful – faces as more fearful when exposed to fear sweat as compared to control odor (Zhou & Chen, 2009). We investigated the specificity of this effect, i.e. whether processing of fearful faces is affected specifically by

  17. Morphological study of human sweat ducts for the investigation of THz-wave interaction (Conference Presentation)

    Science.gov (United States)

    Kawase, Kodo; Tripathi, Saroj R.

    2016-03-01

    Recently, some studies reported that the sweat ducts act as a low-Q-factor helical antenna due to their helical structure, and resonate in the terahertz frequency range according to their structural parameters. According to the antenna theory, when the duct works as a helical antenna, the dimension of the helix plays a key role to determine the frequency of resonance. Therefore, the accurate determination of structural parameters of sweat duct is crucially important to obtain the reliable frequency of resonance and modes of operations. Therefore, here we performed the optical coherence tomography (OCT) of human subjects on their palm and foot to investigate the density, distribution and morphological features of sweat ducts. Moreover, we measured the dielectric properties of stratum corneum using terahertz time domain spectroscopy and based upon this information, we determined the frequency of resonance. We recruited 32 subjects for the measurement and the average duct diameter was 95±11μm. Based upon this information on diameter of duct and THz dielectric properties of stratum corneum (ɛ=5.1±1.3), we have calculated the frequency of resonance of sweat duct. Finally, we determined that the center frequency of resonance was 442±76 GHz. We believe that these findings will facilitate further investigation of the THz-skin interaction and provide guidelines for safety levels with respect to human exposure. We will also report on the EEG measurement while being shined by micro watt order THz waves.

  18. Genotoxicological assessment of two reactive dyes extracted from cotton fibres using artificial sweat.

    Science.gov (United States)

    Leme, Daniela Morais; de Oliveira, Gisele Augusto Rodrigues; Meireles, Gabriela; dos Santos, Tuane Cristina; Zanoni, Maria Valnice Boldrin; de Oliveira, Danielle Palma

    2014-02-01

    Human eyes have a remarkable ability to recognize hundreds of colour shades, which has stimulated the use of colorants, especially for clothing, but toxicological studies have shown that some textile dyes can be hazardous to human health. Under conditions of intense perspiration, dyes can migrate from coloured clothes and penetrate into human skin. Garments made from cotton fabrics are the most common clothing in tropical countries, due to their high temperatures. Aiming to identify safe textile dyes for dyeing cotton fabrics, the genotoxicity [in vitro Comet assay with normal human dermal fibroblasts (NHDF), Tail Intensity] and mutagenicity [Salmonella/microsome preincubation assay (30min), tester strains TA98, TA100, YG1041 and YG1042] of Reactive Blue 2 (RB2, CAS No. 12236-82-7, C.I. 61211) and Reactive Green 19 (RG19, CAS No. 61931-49-5, C.I. 205075) were evaluated both in the formulated form and as extracted from cotton fibres using different artificial sweats. Both the dyes could migrate from cotton fibres to sweat solutions, the sweat composition and pH being important factors during this extraction. However, the dye sweat solutions showed no genotoxic/mutagenic effects, whereas a weak mutagenic potential was detected by the Ames test for both dyes in their formulated form. These findings emphasize the relevance of textile dyes assessment under conditions that more closely resemble human exposure, in order to recognize any hazard. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Regional and circadian variations of sweating rate and body surface temperature in camels (Camelus dromedarius).

    Science.gov (United States)

    Abdoun, Khalid A; Samara, Emad M; Okab, Aly B; Al-Haidary, Ahmed A

    2012-07-01

    It was the aim of this study to investigate the regional variations in surface temperature and sweating rate and to visualize body thermal windows responsible for the dissipation of excess body heat in dromedary camels. This study was conducted on five dromedary camels with mean body weight of 450 ± 20.5 kg and 2 years of age. Sweating rate, skin and body surface temperature showed significant (P surface temperature measured on seven regions of the camel body did not significantly differ. The variation in body surface temperature compared to the variation in skin temperature was higher in the hump compared to the axillary and flank regions, indicating the significance of camel's fur in protecting the skin from daily variation in ambient temperature. Infrared thermography revealed that flank and axillary regions had lower thermal gradients at higher ambient temperature (T(a) ) and higher thermal gradients at lower T(a) , which might indicate the working of flank and axillary regions as thermal windows dissipating heat during the night. Sweating rate showed moderate correlation to skin and body surface temperatures, which might indicate their working as potential thermal drivers of sweating in camels. © 2012 The Authors. Animal Science Journal © 2012 Japanese Society of Animal Science.

  20. Using the Sweat Lodge Ceremony as Group Therapy for Navajo Youth.

    Science.gov (United States)

    Colmant, Stephen A.; Merta, Rod J.

    1999-01-01

    Describes the sweat lodge ceremony used at a residential treatment center located on the Navajo Nation and compares the ceremony to modern group work identifying Yalom's (1995) 11 therapeutic factors of group therapy within the ceremony. Considers widespread use of the ceremony with Native Americans and nonnative Americans as well as…

  1. Measurements of clothing evaporative resistance using a sweating thermal manikin: an overview

    Science.gov (United States)

    WANG, Faming

    2017-01-01

    Evaporative resistance has been widely used to describe the evaporative heat transfer property of clothing. It is also a critical variable in heat stress models for predicting human physiological responses in various environmental conditions. At present, sweating thermal manikins provide a fast and cost-effective way to determine clothing evaporative resistance. Unfortunately, the measurement repeatability and reproducibility of evaporative resistance are rather low due to the complicated moisture transfer processes through clothing. This review article presents a systematical overview on major influential factors affecting the measurement precision of clothing evaporative resistance measurements. It also illustrates the state-of-the-art knowledge on the development of test protocol to measure clothing evaporative resistance by means of a sweating manikin. Some feasible and robust test procedures for measurement of clothing evaporative resistance using a sweating manikin are described. Recommendations on how to improve the measurement accuracy of clothing evaporative resistance are addressed and expected future trends on development of advanced sweating thermal manikins are finally presented. PMID:28566566

  2. Utility of No-Sweat Labels for Apparel Consumers: Profiling Label Users and Predicting Their Purchases.

    Science.gov (United States)

    Dickson, Marsha A.

    2001-01-01

    Responses from 547 of 2,000 consumers indicated consumer support for socially responsible purchasing. For 16%, "No-Sweat" labels indicating the working conditions of apparel makers were a strong purchasing influence. Women, especially unmarried females with lower educational attainment, were most likely to purchase clothing with No-Sweat…

  3. Corrections to the Shapiro Equation used to Predict Sweating and Water Requirements

    Science.gov (United States)

    2008-01-01

    USARIEM TECHNICAL REPORT T07-## CORRECTIONS TO THE SHAPIRO EQUATION USED TO PREDICT SWEATING AND WATER REQUIREMENTS Richard R...daily water requirements based on metabolic rate, climatic conditions, and clothing” as a research priority. Adequate hydration and core temperature...work/rest cycles, water requirements , and maximum endurance times for a given environmental activity and clothing system scenario. The second

  4. The comfort, measured by means of a sweating manikin (WalterTM ...

    African Journals Online (AJOL)

    With the growing importance of clothing comfort in South African and overseas markets for locally produced clothing, the Council for Scientific Industrial Research (CSIR) acquired an advanced sweating fabric manikin for measuring clothing comfort. This preliminary investigation covers the comfort related properties, ...

  5. COGNITIVE AND BEHAVIORAL TREATMENTS OF FEAR OF BLUSHING, SWEATING OR TREMBLING

    NARCIS (Netherlands)

    SCHOLING, A; EMMELKAMP, PMG

    Social phobic patients (n = 30) with fear of blushing, sweating or trembling as the predominant complaint were randomly assigned to three treatment conditions: (1) exposure in vivo followed by cognitive therapy, (2) cognitive therapy followed by exposure in vivo, or (3) a cognitive-behavioural

  6. Determination of silver nanoparticle release from antibacterial fabrics into artificial sweat.

    Science.gov (United States)

    Kulthong, Kornphimol; Srisung, Sujittra; Boonpavanitchakul, Kanittha; Kangwansupamonkon, Wiyong; Maniratanachote, Rawiwan

    2010-04-01

    Silver nanoparticles have been used in numerous commercial products, including textiles, to prevent bacterial growth. Meanwhile, there is increasing concern that exposure to these nanoparticles may cause potential adverse effects on humans as well as the environment. This study determined the quantity of silver released from commercially claimed nanosilver and laboratory-prepared silver coated fabrics into various formulations of artificial sweat, each made according to AATCC, ISO and EN standards. For each fabric sample, the initial amount of silver and the antibacterial properties against the model Gram-positive (S. aureus) and Gram-negative (E. coli) bacteria on each fabric was investigated. The results showed that silver was not detected in some commercial fabrics. Furthermore, antibacterial properties of the fabrics varied, ranging from 0% to greater than 99%. After incubation of the fabrics in artificial sweat, silver was released from the different fabrics to varying extents, ranging from 0 mg/kg to about 322 mg/kg of fabric weight. The quantity of silver released from the different fabrics was likely to be dependent on the amount of silver coating, the fabric quality and the artificial sweat formulations including its pH. This study is the unprecedented report on the release of silver nanoparticles from antibacterial fabrics into artificial sweat. This information might be useful to evaluate the potential human risk associated with the use of textiles containing silver nanoparticles.

  7. Sweating responses and the muscle metaboreflex under mildly hyperthermic conditions in sprinters and distance runners.

    Science.gov (United States)

    Amano, Tatsuro; Ichinose, Masashi; Koga, Shunsaku; Inoue, Yoshimitsu; Nishiyasu, Takeshi; Kondo, Narihiko

    2011-08-01

    To investigate the effects of different training methods on nonthermal sweating during activation of the muscle metaboreflex, we compared sweating responses during postexercise muscle occlusion in endurance runners, sprinters, and untrained men under mild hyperthermia (ambient temperature, 35°C; relative humidity, 50%). Ten endurance runners, nine sprinters, and ten untrained men (maximal oxygen uptakes: 57.5 ± 1.5, 49.3 ± 1.5, and 36.6 ± 1.6 ml·kg(-1)·min(-1), respectively; P sprinters than in untrained men (32.2 ± 4.4 vs. 17.3 ± 2.6 mmHg, respectively; P sprinters and untrained men (0.38 ± 0.07, 0.19 ± 0.03, and 0.11 ± 0.04 mg·cm(-2)·min(-1), respectively; P sprinters and untrained men. Our results suggest that the specificity of training modalities influences the sweating response during activation of the muscle metaboreflex. In addition, these results imply that a greater activation of the muscle metaboreflex does not cause a greater sweating response in sprinters.

  8. In vivo single human sweat gland activity monitoring using coherent anti-Stokes Raman scattering and two-photon excited autofluorescence microscopy.

    Science.gov (United States)

    Chen, X; Gasecka, P; Formanek, F; Galey, J-B; Rigneault, H

    2016-04-01

    Eccrine sweat secretion is of central importance for control of body temperature. Although the incidence of sweat gland dysfunction might appear of minor importance, it can be a real concern for people with either hypohidrosis or hyperhidrosis. However, sweat gland function remains relatively poorly explored. To investigate the function of single human sweat glands. We describe a new approach for noninvasive imaging of single sweat gland activity in human palms in vivo up to a depth of 100 μm, based on nonlinear two-photon excited autofluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS). These techniques appear to be useful compared with approaches already described for imaging single sweat gland activity, as they allow better three-dimensional spatial resolution of sweat pore inner morphology and real-time monitoring of individual sweat events. By filling the sweat pore with oil and tuning the CARS contrast at 2845 cm(-1) , we imaged the ejection of sweat droplets from a single sweat gland when oil is pushed out by sweat flow. On average, sweat events lasted for about 30 s every 3 min under the conditions studied. On the other hand, about 20% of sweat glands were found inactive. TPEF and CARS were also used to study, at the single pore level, the antiperspirant action of aluminium chlorohydrate (ACH) and to reveal, for the first time in vivo, the formation of a plug at the pore entrance, in agreement with reported ACH antiperspirant mechanisms. Although data were acquired on human palms, these techniques show great promise for a better understanding of sweat secretion physiology and should be helpful to improve the efficacy of antiperspirant formulations. © 2015 British Association of Dermatologists.

  9. Peran Kecepatan Angin Terhadap Peningkatan Kenyamanan Termis Manusia Di Lingkungan Beriklim Tropis Lembab (the Role of Wind Velocity on Increasing Human Thermal Comfort in Hot and Humid Environment)

    OpenAIRE

    Sangkertadi, Sangkertadi

    2006-01-01

    The most important factors which influence the condition of thermal comfort are clothing, temperature, humidity, air velocity, and types of activities. In hot and humid climate, feeling of comfort are associated with sweating. Air velocity can cool building occupants by increasing convective and evaporative heat loses. This paper intends to explore the techniques for evaluating of thermal comfort especially with introduction of PMV and DISC scales for the tropical humid environment. The study...

  10. Laser-Based Characterization of Nuclear Fuel Plates

    Energy Technology Data Exchange (ETDEWEB)

    James A. Smith; David L. Cottle; Barry H. Rabin

    2013-07-01

    Ensuring the integrity of fuel-clad and clad-clad bonding in nuclear fuels is important for safe reactor operation and assessment of fuel performance, yet the measurement of bond strengths in actual fuels has proved challenging. The laser shockwave technique (LST) originally developed to characterize structural adhesion in composites is being employed to characterize interface strength in a new type of plate fuel being developed at Idaho National Laboratory (INL). LST is a non-contact method that uses lasers for the generation and detection of large-amplitude acoustic waves and is well suited for application to both fresh and irradiated nuclear-fuel plates. This paper will report on initial characterization results obtained from fresh fuel plates manufactured by different processes, including hot isostatic pressing, friction stir welding, and hot rolling.

  11. Recovery of energy from geothermal brine and other hot water sources

    Science.gov (United States)

    Wahl, III, Edward F.; Boucher, Frederic B.

    1981-01-01

    Process and system for recovery of energy from geothermal brines and other hot water sources, by direct contact heat exchange between the brine or hot water, and an immiscible working fluid, e.g. a hydrocarbon such as isobutane, in a heat exchange column, the brine or hot water therein flowing countercurrent to the flow of the working fluid. The column can be operated at subcritical, critical or above the critical pressure of the working fluid. Preferably, the column is provided with a plurality of sieve plates, and the heat exchange process and column, e.g. with respect to the design of such plates, number of plates employed, spacing between plates, area thereof, column diameter, and the like, are designed to achieve maximum throughput of brine or hot water and reduction in temperature differential at the respective stages or plates between the brine or hot water and the working fluid, and so minimize lost work and maximize efficiency, and minimize scale deposition from hot water containing fluid including salts, such as brine. Maximum throughput approximates minimum cost of electricity which can be produced by conversion of the recovered thermal energy to electrical energy.

  12. China's 'Hot Money' Problems

    National Research Council Canada - National Science Library

    Martin, Michael F; Morrison, Wayne M

    2008-01-01

    .... The recent large inflow of financial capital into China, commonly referred to as "hot money," has led some economists to warn that such flows may have a destabilizing effect on China's economy...

  13. Hot Weather Tips

    Science.gov (United States)

    ... hot, heavy meals and don’t use the oven. Monitor medications: Find out if the person’s medications ... nia.nih.gov Photo: By High Contrast (Own work) [CC BY 3.0 de ( http://creativecommons.org/ ...

  14. Hot Dry Rock; Geothermal Energy

    Energy Technology Data Exchange (ETDEWEB)

    None

    1990-01-01

    The commercial utilization of geothermal energy forms the basis of the largest renewable energy industry in the world. More than 5000 Mw of electrical power are currently in production from approximately 210 plants and 10 000 Mw thermal are used in direct use processes. The majority of these systems are located in the well defined geothermal generally associated with crustal plate boundaries or hot spots. The essential requirements of high subsurface temperature with huge volumes of exploitable fluids, coupled to environmental and market factors, limit the choice of suitable sites significantly. The Hot Dry Rock (HDR) concept at any depth originally offered a dream of unlimited expansion for the geothermal industry by relaxing the location constraints by drilling deep enough to reach adequate temperatures. Now, after 20 years intensive work by international teams and expenditures of more than $250 million, it is vital to review the position of HDR in relation to the established geothermal industry. The HDR resource is merely a body of rock at elevated temperatures with insufficient fluids in place to enable the heat to be extracted without the need for injection wells. All of the major field experiments in HDR have shown that the natural fracture systems form the heat transfer surfaces and that it is these fractures that must be for geothermal systems producing from naturally fractured formations provide a basis for directing the forthcoming but, equally, they require accepting significant location constraints on HDR for the time being. This paper presents a model HDR system designed for commercial operations in the UK and uses production data from hydrothermal systems in Japan and the USA to demonstrate the reservoir performance requirements for viable operations. It is shown that these characteristics are not likely to be achieved in host rocks without stimulation processes. However, the long term goal of artificial geothermal systems developed by systematic

  15. Leaching from the stratum corneum does not explain the previously reported elevated potassium ion concentration in sweat.

    Science.gov (United States)

    Buono, Michael J; Stone, Michael; Cannon, Daniel T

    2016-03-01

    The purpose of this study was to determine if K+ is leached from the stratum corneum when sweat is present on the skin's surface. The results will help address whether sweat [K+] previously reported in the literature are artifactually elevated as a result of K+ leaching. Twelve (six female, six male) healthy volunteers participated in this study. After thorough skin cleansing and preparation with isopropyl alcohol and high-performance liquid chromatography-grade distilled water, three sites were chosen and a 50 μL drop of artificial sweat was pipetted directly onto the skin. The artificial sweat had a [K+] of 4 mEq·L-1, an osmolality of 120 mosm·L-1, and a pH of 6.0. Immediately following, a clear plastic cover slip (~6 cm2) with a shallow 0.8 cm2 convex impression in the center was applied over each drop, preventing evaporation. Each sample was allowed to sit on the forearm, under the plastic cover slip, for 10 min. The mean (±SD) [K+] in 'artificial' sweat not exposed to the skin was measured to be 4.2±0.4 mEq·L-1. After 10 min of exposure to the stratum corneum of the forearm, the artificial sweat had a mean (±SD) [K+] of 3.9±0.3 mEq·L-1. There was no significant difference (p>0.05) in the [K+] between the control artificial sweat and the samples collected after 10 min of exposure to forearm skin. These results do not support the hypothesis that significant K+ leaching from the stratum corneum into standing sweat is the cause for the previously reported elevated sweat [K+].

  16. Effect of periglandular ionic composition and transport inhibitors on rhesus monkey eccrine sweat gland function in vitro.

    Science.gov (United States)

    Sato, F; Sato, K

    1987-12-01

    1. The effects of peritubular ions and transport inhibitors were studied on methacholine (MCH)-induced sweat secretion by the isolated, cannulated monkey palm sweat glands in vitro and on the transepithelial and basolateral membrane potential (p.d.). 2. Sweat secretory rate was a curvilinear function of peritubular Na+ and Cl- concentration. Among the anion substitutes only Br- was able to totally substitute for Cl-. Presence of HCO3- or H2PO4- in the bath was not essential. 3. Both bumetanide and furosemide inhibited sweat secretion in a dose-dependent manner with the median effective concentration (EC50) of 3 X 10(-6) and 3 X 10(-5) M, respectively. 4. Bumetanide (10(-4) M) had no significant effect on basolateral membrane p.d. but nearly abolished the transepithelial p.d. 5. Hydrochlorothiazide (HCTZ, 3 X 10(-4) M) inhibited sweat secretion by only 35%. Inhibitors of ion exchangers amiloride (10(-4) M) and DIDS (4,4'-diisothiocyanostilbene-2,2'-disulphonic acid, 10(-4) M) lowered sweat secretion by less than 20%. 6. Removal of peritubular K+ as well as addition of 5 mM-Ba2+ also inhibited sweat rate. 5 mM-Ba2+ abolished the transepithelial p.d. and depolarized the basolateral p.d. by 26 mV, although the effects of Ba2+ on sweating and the transepithelial p.d. were only transient. 7. The data raise a possibility that either the NaCl or Na+-K+-2Cl- co-transport system or both may be involved in MCH-induced sweat secretion, whereas the role of parallel ion exchangers, if any, may be rather minor.

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the ... Help Enroll in the Living WIth Type 2 Diabetes Program Food & Fitness Food Recipes Planning Meals What Can I Eat Weight Loss Fitness In My Community Calendar of Events ...

  18. mill grinding plates

    African Journals Online (AJOL)

    User

    ABSTRACT. Maize was milled either 'wet' or ''dry'' using locally-manufactured milling plates. Samples of milled maize were taken and analyzed for elemental iron (Fe). Results show that iron particles from milling plates contaminates the milled maize and that the level of contamination increases with the quantity of milled ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday ... Foods donate en -- Limited Time MATCH Offer - limited- ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  2. Accumulation of FDG in axillary sweat glands in hyperhidrosis: a pitfall in whole-body PET examination

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsson, H. [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Celsing, F. [Department of Haematology and Infectious Diseases, Karolinska Hospital, Stockholm (Sweden); Ingvar, M. [Department of Cognitive Neurophysiology, Karolinska Hospital, Stockholm (Sweden); Stone-Elander, S. [Department of Cognitive Neurophysiology, Karolinska Hospital, Stockholm (Sweden)]|[Karolinska Pharmacy, Stockholm (Sweden); Larsson, S.A. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden)

    1998-03-27

    A diabetic male with severe autonomic neuropathy and recently discovered Hodgkin`s disease demonstrated bilateral uptake of [2-{sup 18}F]-2-fluoro-2-deoxy-d-glucose (FDG) in the axillary sweat glands during profuse sweating caused by hypoglycaemia at positron emission tomography examination. It is not yet clear whether the sweating interfered with the distribution of the radiopharmaceutical. Regardless of the cause or mechanism for the uptake, the finding is clinically relevant. A bilateral symmetrical accumulation of FDG in the axillae of a tumour patient does not necessarily indicate malignant involvement of the lymph nodes. (orig.) With 1 fig., 9 refs.

  3. Wetting dynamics beneath fluid drops impacting on hot surfaces

    Science.gov (United States)

    Harth, Kirsten; van Limbeek, Michiel A. J.; Shirota, Minori; Sun, Chao; Lohse, Detlef

    Fluid droplets encountering a phase transition when they impact a target surface are involved in many applications, e.g., spray cooling or painting / coating, ink-jet and 3D printing, soldering, firefighting using sprinklers. Drop impact on hot plates is an emerging topic, involving a complex interplay of hydrodynamics, heat flux and the occurring phase transition, involving large spatial and temporal gradients. Whether and to what extent droplets touch the surface is of immense importance for the overall heat transfer. High-speed total internal reflection imaging allows us to discriminate wetted and vapor-covered regions of the substrate. We study the transient wetting behaviour of the plate by varying the latent heat of the droplet. The characteristic cooling time of the plate is not solely determined by the plate properties. In addition to current literature, we show that in those cases the wetting pattern is both spatially and temporally inhomogeneous.

  4. Pixelated neutron image plates

    Science.gov (United States)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  5. Development of equipment for in situ studies of biofilm in hot water systems

    DEFF Research Database (Denmark)

    Bagh, Lene Karen; Albrechtsen, Hans-Jørgen; Arvin, Erik

    1999-01-01

    New equipment was developed for in situ studies of biofilms in hot water tanks and hot water pipes under normal operation and pressure. Sampling ports were installed in the wall of a hot water tank and through these operating shafts were inserted with a test plug in the end. The surface of the test...... in sampling ports in a by-pass. Heterotrophic plate counts (HPC) revealed 10(4)-10(6) CFU cm(-2) on the test plugs in the hot water system after an exposure period of 7 d. The number of bacteria was not influenced by the location of the plug within each cluster of plugs in the distribution system...

  6. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  7. Plating in Top Agar

    OpenAIRE

    sprotocols

    2014-01-01

    1. Warm plates to room temperature before use. Cold plates causes the top agar to solidify irregularly. DO not warm plates to 37° as the top agar will take forever to solidify. - Prepare top agar as the appropriate liquid medium with 0.7% agar. Keeping 100 mL bottles is convenient. For phages, use λ top agar, which is less rich and yields bigger plaques. - Melt top agar in the microwave completely. Allow the agar to boil after liquification; incompletely melted agar looks liquid, but is...

  8. IR Hot Wave

    Energy Technology Data Exchange (ETDEWEB)

    Graham, T. B.

    2010-04-01

    The IR Hot Wave{trademark} furnace is a breakthrough heat treatment system for manufacturing metal components. Near-infrared (IR) radiant energy combines with IR convective heating for heat treating. Heat treatment is an essential process in the manufacture of most components. The controlled heating and cooling of a metal or metal alloy alters its physical, mechanical, and sometimes chemical properties without changing the object's shape. The IR Hot Wave{trademark} furnace offers the simplest, quickest, most efficient, and cost-effective heat treatment option for metals and metal alloys. Compared with other heat treatment alternatives, the IR Hot Wave{trademark} system: (1) is 3 to 15 times faster; (2) is 2 to 3 times more energy efficient; (3) is 20% to 50% more cost-effective; (4) has a {+-}1 C thermal profile compared to a {+-}10 C thermal profile for conventional gas furnaces; and (5) has a 25% to 50% smaller footprint.

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths Common Terms Research Resources ... to manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy- ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... on one side, cut it again so you will have three sections on your plate. Fill the ...

  14. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  15. Create Your Plate

    Medline Plus

    Full Text Available ... one side, cut it again so you will have three sections on your plate. Fill the largest ... home, the office, or somewhere in between, you have an easy portion control solution that works. Last ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... and Pacific Islanders American Indian/Alaska Native Programs Older Adults Family Link Diabetes EXPO Upcoming Diabetes EXPOs ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... losing weight. Creating your plate lets you still choose the foods you want, but changes the portion ... dairy or both as your meal plan allows. Choose healthy fats in small amounts. For cooking, use ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... of Diabetes Research & Practice Home We Are Research Leaders World's Largest Diabetes Meeting Recent Advances Type 1 ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ...

  19. Humvee Armor Plate Drilling

    National Research Council Canada - National Science Library

    2004-01-01

    When drilling holes in hard steel plate used in up-armor kits for Humvee light trucks, the Anniston Army Depot, Anniston, Alabama, requested the assistance of the National Center for Defense Manufacturing and Machining (NCDMM...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food Choices In ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ... Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice Resources Ways ...

  2. Tactile cues significantly modulate the perception of sweat-induced skin wetness independently of the level of physical skin wetness.

    Science.gov (United States)

    Filingeri, Davide; Fournet, Damien; Hodder, Simon; Havenith, George

    2015-06-01

    Humans sense the wetness of a wet surface through the somatosensory integration of thermal and tactile inputs generated by the interaction between skin and moisture. However, little is known on how wetness is sensed when moisture is produced via sweating. We tested the hypothesis that, in the absence of skin cooling, intermittent tactile cues, as coded by low-threshold skin mechanoreceptors, modulate the perception of sweat-induced skin wetness, independently of the level of physical wetness. Ten males (22 yr old) performed an incremental exercise protocol during two trials designed to induce the same physical skin wetness but to induce lower (TIGHT-FIT) and higher (LOOSE-FIT) wetness perception. In the TIGHT-FIT, a tight-fitting clothing ensemble limited intermittent skin-sweat-clothing tactile interactions. In the LOOSE-FIT, a loose-fitting ensemble allowed free skin-sweat-clothing interactions. Heart rate, core and skin temperature, galvanic skin conductance (GSC), and physical (w(body)) and perceived skin wetness were recorded. Exercise-induced sweat production and physical wetness increased significantly [GSC: 3.1 μS, SD 0.3 to 18.8 μS, SD 1.3, P FIT and LOOSE-FIT (P > 0.05). However, the limited intermittent tactile inputs generated by the TIGHT-FIT ensemble reduced significantly whole-body and regional wetness perception (P < 0.01). This reduction was more pronounced when between 40 and 80% of the body was covered in sweat. We conclude that the central integration of intermittent mechanical interactions between skin, sweat, and clothing, as coded by low-threshold skin mechanoreceptors, significantly contributes to the ability to sense sweat-induced skin wetness. Copyright © 2015 the American Physiological Society.

  3. Study on moisture absorption and sweat discharge of honeycomb polyester fiber

    Science.gov (United States)

    Feng, Aifen; Zhang, Yongjiu

    2015-07-01

    The moisture absorption and liberation properties of honeycomb polyester fiber were studied in order to understand its moisture absorption and sweat discharge. Through testing moisture absorption and liberation regains of honeycomb polyester fiber and normal polyester fiber in standard atmospheric conditions, their moisture absorption and liberation curves were depicted, and the regression equations of moisture regains to time during their reaching the balance of moisture absorption and moisture liberation were obtained according to the curves. Their moisture absorption and liberation rate curves were analyzed and the regression equations of the rates to time were obtained. The results shows that the moisture regain of honeycomb polyester fiber is much bigger than the normal polyester fiber's, and the initial moisture absorption and moisture liberation rates of the former are much higher than the latter's, so that the moisture absorbance and sweat discharge of honeycomb polyester fiber are excellent.

  4. A comparison of fingerprint sweat corrosion of different alloys of brass.

    Science.gov (United States)

    Sykes, Stephanie; Bond, John W

    2013-01-01

    Fingerprint sweat from 40 donors was deposited onto samples of five α and α + β phase brasses, comprising five alloys with different copper and zinc concentrations, two of which also had the addition of small concentrations of lead. Visual grading of the visibility of the corrosion revealed that brasses with the least amount of zinc produced the most visible and fully formed fingerprints from the most donors. Consideration of previously reported mechanisms for the corrosion of brass suggests red copper (I) oxide as a likely corrosion product for low zinc brasses, and a consideration of the color, composition, and solubility of fingerprint sweat corrosion products suggests that copper (I) oxide produces good contrast and visibility with the brass substrate. Scanning electron microscope images of the corrosion of all five alloys confirmed the enhanced contrast between corroded and uncorroded areas for low zinc alloys. © 2012 American Academy of Forensic Sciences.

  5. Optimization study for metabolomics analysis of human sweat by liquid chromatography-tandem mass spectrometry in high resolution mode.

    Science.gov (United States)

    Calderón-Santiago, M; Priego-Capote, F; Jurado-Gámez, B; Luque de Castro, M D

    2014-03-14

    Sweat has recently gained popularity as a potential tool for diagnostics and biomarker monitoring as it is a non-invasive biofluid the composition of which could be modified by certain pathologies, as is the case with cystic fibrosis, which increases chloride levels in sweat. The aim of the present study was to develop an analytical method for analysis of human sweat by liquid chromatography-mass spectrometry (LC-Q-TOF MS/MS) in high resolution mode. Thus, different sample preparation strategies and different chromatographic modes (HILIC and C18 reverse modes) were compared to check their effect on the profile of sweat metabolites. Forty-one compounds were identified by the MS/MS information obtained with a mass tolerance window below 4 ppm. Amino acids, dicarboxylic acids and other interesting metabolites such as inosine, choline, uric acid and tyramine were identified. Among the tested protocols, direct analysis after dilution was a suited option to obtain a representative snapshot of sweat metabolome. In addition, sample clean up by C18 SpinColumn SPE cartridges improved the sensitivity of most identified compounds and reduced the number of interferents. As most of the identified metabolites are involved in key biochemical pathways, this study opens new possibilities to the use of sweat as a source of metabolite biomarkers of specific disorders. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Prediction of mean skin temperature for use as a heat strain scale by introducing an equation for sweating efficiency

    Science.gov (United States)

    Kubota, H.; Kuwabara, K.; Hamada, Y.

    2014-09-01

    The present paper made the heat balance equation (HBE) for nude or minimally clad subjects a linear function of mean skin temperature ( t sk) by applying new equations for sweating efficiency ( η sw) and thermoregulatory sweat rate ( S wR). As the solution of the HBE, the equation predicting t sk was derived and used for a heat strain scale of subjects. The η sw was proportional to the reciprocal of S w/ E max ( S w, sweat rate; E max maximum evaporative capacity) and the S wR was proportional to t sk with a parameter of the sweating capacity of the subject. The errors of predicted t sk from observations due to the approximation of η sw were examined based on experimental data conducted on eight young male subjects. The value of errors of t sk was -0.10 ± 0.42 °C (mean ± sample standard deviation (SSD)). We aim to apply the predicted t sk of a subject at a level of sweating capacity as a heat strain scale of a function of four environmental factors (dry- and wet-bulb temperatures, radiation, and air velocity) and three human factors (metabolic rate, sweating capacity, and clothing (≤0.2clo)).

  7. Nanoduct Sweat Conductivity Measurements in 2664 Patients: Relationship to Age, Arterial Blood Gas, Serum Electrolyte Profiles and Clinical Diagnosis

    Science.gov (United States)

    Sezer, Rabia Gonul; Aydemir, Gokhan; Akcan, Abdullah Baris; Paketci, Cem; Karaoglu, Abdulbaki; Aydinoz, Secil; Bozaykut, Abdulkadir

    2013-01-01

    Background The Nanoduct® device has acceptable diagnostic accuracy, but there is not enough systematic data supporting its usage in the diagnosis of cystic fibrosis (CF). Methods A retrospective review of patients with an indication for the sweat test was conducted. The conductivity test was repeated in patients who had values higher than 60 mmol/L, and they were referred for sweat chloride measurements. Associations between sweat conductivity measurements and age, gender, (pH, HCO3, pCO2, Na, K, Cl), family history, consanguinity, indications for the test and number of hospitalization were studied. Results Among 2,664 patients, 16 children had sweat conductivity values higher than 80. The median age of patients diagnosed with CF was 4 months old. Age, pH, HCO3, Na, Cl, K and the sweat conductivity test were statistically related (P conductivity test and the sweat test. Conclusions Patients suspected to have CF can be screened using the Nanoduct® conductivity device in non-qualified centers. PMID:23390474

  8. Epidemiological and histopathological analysis of 40 apocrine sweat gland carcinomas in dogs: a retrospective study

    Directory of Open Access Journals (Sweden)

    Kycko Anna

    2016-09-01

    Full Text Available Introduction: Apocrine sweat gland carcinomas (ASGCs are malignant neoplasms of dogs and other animals, rarely reported worldwide. The aim of this study was to summarise the occurrence of this cancer in a population of dogs in Poland between 2009 and 2014 with regards to histological features and body location of the tumours, as well as age, sex and breed of the cancer-affected dogs.

  9. Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress.

    Science.gov (United States)

    Schlader, Zachary J; Gagnon, Daniel; Lucas, Rebekah A I; Pearson, James; Crandall, Craig G

    2015-02-15

    This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm(-2)·min(-1)) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm(-2)·min(-1), P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm(-2)·min(-1); P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress. Copyright © 2015 the American Physiological Society.

  10. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    Science.gov (United States)

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  11. Dissolution of cemented carbide powders in artificial sweat: implications for cobalt sensitization and contact dermatitis.

    Science.gov (United States)

    Stefaniak, Aleksandr B; Harvey, Christopher J; Virji, M Abbas; Day, Gregory A

    2010-10-06

    Skin exposure to cobalt-containing materials can cause systemic immune sensitization and upon repeat contact, elicitation of allergic contact dermatitis (ACD). Data on cobalt dissolution rates are needed to calculate uptake through skin and for development of models to understand risk of sensitization or dermatitis. The purpose of this research was to measure the dissolution kinetics of feedstock and process-sampled powders encountered in the production of hard metal alloys using artificial sweat. The physicochemical properties of each material were characterized prior to evaluation of dissolution behavior. Variations in artificial sweat solvent pH and chemistry were used to understand critical factors in dissolution. Dissolution of cobalt, tungsten, and tungsten carbide was often biphasic with the initial rapid phase being up to three orders of magnitude faster than the latter long-term phase. Artificial sweat pH did not influence dissolution of cobalt or tungsten carbide. Solvent composition had little influence on observed dissolution rates; however, vitamin E suppressed the dissolution of cobalt and tungsten carbide from sintered particles obtained from a chamfer grinder. There was no effect of particle size on dissolution of feedstock cobalt, tungsten, tungsten carbide, and admixture powders. Particle physicochemical properties influenced observed dissolution rates with more cobalt and tungsten carbide dissolving from chamfer grinder particles compared to the feedstock powders or admixture powder. Calculations using the observed dissolution rates revealed that skin exposure concentrations were similar to concentrations known to induce cobalt sensitization and elicit ACD. Observed dissolution rates for cobalt in artificial sweat indicate that dermal uptake may be sufficient to induce cobalt sensitization and allergic dermatitis.

  12. Analisis Brand Equity Pocari Sweat Dalam Persaingan Industri Minuman (Studi Kasus: Mahasiswa Di Bogor)

    OpenAIRE

    Pratama, Fredie; Jono M Munandar

    2010-01-01

    Isotonic drink is a new kind of product in Indonesian consumer goods. This kind of product entered Indonesian market in mid-80s. However, isotonic drink industry is growing up along with the increase of people's welfare and awareness of body health. One of isotonic drinks marketed in Indonesia is Pocari Sweat, produced by PT Amerta Indah Otsuka, which is the market leader in Indonesian isotonic drink industry. High level of competition put more burdens on the producer. PT Amerta has to ensure...

  13. Effects of age on histological parameters of the sweat glands of Nellore cattle

    Directory of Open Access Journals (Sweden)

    Mara Regina Bueno de Mattos Nascimento

    2015-04-01

    Full Text Available The sweat glands are important in thermoregulation of cattle in a warm environment as they help dissipate heat through evaporation. Studies on gland histology are important to define its secretion potential and the capacity of perspiration and heat removal. The objective of this study was to determine, by histomorphometry, glandular epithelium height, the depth of the gland, length of the glandular portion and number of glands per cm2 of the sweat glands of the three age groups of Nellore cattle. Thirty females were used in this study. They were equally divided into calves, heifers and cows. Histological sections were obtained and analyzed by digital images in Trinocular BX40 Olympus microscope coupled to an Oly - 200 camera, connected to a computer. The images were obtained with microscope with 2x, 4x, 10x and 40x magnification objectives. The measurements were performed using HL Image 97 program. The height of glandular epithelium, depth of the glands, length and density of the glandular portion per cm2 , were all analyzed. The calves showed greater height of the glandular epithelium than heifers (P = 0.0024, and cows (P = 0.0191. The depth of the gland was not influenced by age. Cows had higher length of secretory portion than heifers (P = 0.0379 and calves (P = 0.0077. Heifers had a greater number of sweat glands per cm2 of skin than cows (P = 0.023. In cattle, the height of glandular epithelium and the density decreases as animals get older. On the other hand, the length of the secretor portion increases but with no changes in the depth of the sweat glands

  14. Control of skin blood flow, sweating, and heart rate - Role of skin vs. core temperature

    Science.gov (United States)

    Wyss, C. R.; Brengelmann, G. L.; Johnson, J. M.; Rowell, L. B.; Niederberger, M.

    1974-01-01

    A study was conducted to generate quantitative expressions for the influence of core temperature, skin temperature, and the rate of change of skin temperature on sweat rate, skin blood flow, and heart rate. A second goal of the study was to determine whether the use of esophageal temperature rather than the right atrial temperature as a measure of core temperature would lead to different conclusions about the control of measured effector variables.

  15. Exercise performance over the menstrual cycle in temperate and hot, humid conditions.

    Science.gov (United States)

    Janse DE Jonge, Xanne A K; Thompson, Martin W; Chuter, Vivienne H; Silk, Leslie N; Thom, Jeanette M

    2012-11-01

    This study investigated the effects of the menstrual cycle on prolonged exercise performance both in temperate (20°C, 45% relative humidity) and hot, humid (32°C, 60% relative humidity) conditions. For each environmental condition, 12 recreationally active females were tested during the early follicular (day 3-6) and midluteal (day 19-25) phases, verified by measurement of estradiol and progesterone. For all four tests, thermoregulatory, cardiorespiratory, and perceptual responses were measured during 60 min of exercise at 60% of maximal oxygen consumption followed by an incremental test to exhaustion. No differences in exercise performance between menstrual cycle phases were found during temperate conditions (n = 8) despite a higher resting and submaximal exercise core temperature (Tc) in the luteal phase. In hot, humid conditions (n = 8), however, prolonged exercise performance, as exercise time to fatigue, was significantly reduced during the luteal phase. This finding was not only accompanied by higher resting and submaximal exercise Tc but also a higher rate of increase in Tc during the luteal phase. Furthermore, submaximal exercise HR, minute ventilation, and RPE measures were higher during the luteal phase in hot, humid conditions. No significant differences were found over the menstrual cycle in heat loss responses (partitional calorimetry, sweat rate, upper arm sweat composition) and Tc at exhaustion. In temperate conditions, no changes in prolonged exercise performance were found over the menstrual cycle, whereas in hot, humid conditions, performance was decreased during the luteal phase. The combination of both exercise and heat stress with the elevated luteal phase Tc at the onset of exercise resulted in physiological and perceptual changes and a greater thermosensitivity, which may explain the decrease in performance.

  16. Venlafaxine in management of hot flashes in women with breast cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Ramaswami, Ramya; Villarreal, Marcos Daniel; Pitta, Dina Marie; Carpenter, Janet S; Stebbing, Justin; Kalesan, Bindu

    2015-07-01

    Toxicity due to treatment causes a negative impact on quality of life in breast cancer survivors. Hot flash symptoms, described as intense sensations of heat, sweating and flushing occur in more than 50 % of breast cancer patients taking tamoxifen. We hypothesized that venlafaxine, a selective-norepinephrine reuptake inhibitor drug, was effective for reducing patient-reported hot flash scores among women treated for breast cancer compared to other non-hormonal treatments. We searched Medline, Scopus, and Cochrane Central Register of Controlled Trials from inception till May 2015 for venlafaxine (75 mg once daily or greater) with non-hormonal comparators for the treatment of hot flashes in female breast cancer patients. The primary outcome was hot flash score (derived from patient-reported hot flash severity and frequency) in randomized controlled trials. Standardized mean differences (SMD) were calculated for each study due to variation in the outcome measures. Heterogeneity was determined using I (2) statistics, and publication bias was assessed using a contour funnel plot and Egger's tests. Pooled analyses demonstrated that venlafaxine significantly reduced hot flash scores compared to the trial comparators (overall SMD 2.06; 95% confidence interval (CI) [0.40, 3.72]). There was significant heterogeneity among these studies (I (2) = 98.7%, P hot flashes among women with breast cancer. This review highlights methodological issues that arise from eligible trials and recommends a collaborative approach in survivorship studies.

  17. Men Smelling Women: Null Effects of Exposure to Ovulatory Sweat on Men's Testosterone

    Directory of Open Access Journals (Sweden)

    James R. Roney

    2012-10-01

    Full Text Available Males of many species, humans included, exhibit rapid testosterone increases after exposure to conspecific females. Female chemical stimuli are sufficient to trigger these responses in many nonhuman species, which raises the possibility of similar effects in humans. Recently, Miller and Maner (2010 reported that smelling T-shirts worn by women near ovulation can trigger testosterone responses in men; however, men were aware that they were smelling women's scents, and thus mental imagery associated with that knowledge may have contributed to the hormone responses. Here, we collected axillary sweat samples from women on days near ovulation. In a crossover design, men who were not explicitly aware of the specific stimuli smelled the sweat samples in one session and water samples in a second session. There were no differences in testosterone responses across the experimental conditions. Our null findings suggest that the relevant chemical signal is not found in axillary sweat, and/or that knowledge of the stimulus source is necessary for hormone responses. These results thus suggest boundary conditions for the effects reported in Miller and Maner (2010, and recommend further research to define the precise circumstances under which men's testosterone may respond to chemosensory cues from women.

  18. Indirect measurements of sweat electrolyte concentration in the laboratory diagnosis of cystic fibrosis

    Science.gov (United States)

    Heeley, M.; Woolf, D.; Heeley, A.

    2000-01-01

    AIM—To investigate whether analytical methods based on the colligative physical chemical properties of ions or solutes in sweat are less effective than the specific measurement of electrolytes in the diagnosis of cystic fibrosis (CF).
METHODS—A single sweat sample was collected (Macroduct) from each of 211 infants and children, of whom 57 had CF, for the measurment of sodium, chloride, osmolality, and conductivity.
RESULTS—The ranges within which CF and non-CF individual values overlapped (equivocal ranges), were wider for sodium and osmolality measurement than for chloride or conductivity. Neither of the latter two measurements provided a discriminatory advantage over the other. The utilisation of broadly based age related ranges for non-CF control subjects served to improve the discriminatory power of all four measurements to an extent that, in this cohort, both chloride and conductivity provided complete discrimination.
CONCLUSION—Sweat conductivity is as effective as chloride measurement in the laboratory diagnosis of CF.

 PMID:10799439

  19. Intraparotid Location of the Great Auricular Nerve: A New Anatomical Basis for Gustatory Sweating Syndrome.

    Science.gov (United States)

    Toure, Gaoussou

    2015-11-01

    Gustatory sweating syndrome (also known as Frey syndrome or auriculotemporal nerve syndrome) is thought to result from a lesion of the auriculotemporal nerve. A lesion of this nerve can lead to aberrant regeneration of nerve fibers to the sweat glands and blood vessels. The occurrence of signs outside the region of the auriculotemporal nerve prompted the author to search for another anatomical basis for this syndrome. The author dissected 46 great auricular nerves from their origin to the parotid gland and in the infratemporal fossa. The author investigated the different connections of the great auricular nerve with the facial nerve and the auriculotemporal nerve. The great auricular nerve was found to essentially be a parotid nerve. There was a set of intraparotid nerve connections on 14 of the 46 half-heads that were dissected. The author was able to discern three types of parotid great auricular nerve connections, which he designates as either type 1, connection with the trunk of the facial nerve and its branches; type 2, connection with the auriculotemporal nerve; or type 3, connection with the auriculotemporal nerve and the facial nerve with the formation of an intraparotid nerve circle. Having clearly established the nerve connections of the great auricular nerve, the author believes that it is primarily this nerve that is responsible for gustatory sweating syndrome. This allows for a better understanding of the sympathetic nervous system features and the manifestation of the syndrome outside the region of the auriculotemporal nerve.

  20. Formaldehyde solutions in simulated sweat increase human melanoma but not normal human keratinocyte cells proliferation.

    Science.gov (United States)

    Rizzi, M; Cravello, B; Tonello, S; Renò, F

    2016-12-01

    Our skin is in close contact with clothes most of the time thus risking potentially noxious chemicals contact. One of the potentially harmful manufacturing by-products that can be released by textiles when sweating is formaldehyde, used as an anti-crease treatment. As it is known to be carcinogenic to humans and a potent skin sensitizer, the aim of this study was to investigate its effects on both normal human keratinocytes (HaCaT cells) and on a highly invasive malignant melanoma cell line (SK-MEL-28) in order to contribute to the definition of safety cut-off to be applied to the production processes. Formaldehyde concentrations below the commonly accepted limits (10-50μM) were obtained by diluting formaldehyde in simulated sweat (UNI EN ISO 105-E04). The effects on cell proliferation were evaluated by cell counting, while ERK pathway activation was evaluated by western blot. Low concentrations of formaldehyde (10μM) in both acidic and alkaline simulated sweat were able to increase malignant melanoma cell proliferation, while not affecting normal keratinocytes. Melanoma proliferation increase was greater in acidic (pH=5.5) than in alkaline (pH=8) conditions. Moreover, formaldehyde stimulation was able to induce ERK pathway activation. The data obtained suggest the need for an even increasing attention to the potentially harmful effects of textile manufacturing by-products. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Circular polarization induced by the three-dimensional chiral structure of human sweat ducts.

    Science.gov (United States)

    Hayut, Itai; Ben Ishai, Paul; Agranat, Aharon J; Feldman, Yuri

    2014-04-01

    The upper part of the human eccrine sweat ducts, embedded within the epidermis layer, have a well-defined helical structure. It was recently suggested that, as electromagnetic entities, the sweat ducts interact with sub-mm waves [Y. Feldman et al., Phys. Rev. Lett. 100, 128102 (2008)]. Although correlation between changes in the reflectance spectrum in this frequency range and physiological activities has been shown, a direct link between the electromagnetic reflection and the helical structure itself has remained to be established. The fact that the sweat ducts manifest natural homochirality is henceforth used to produce this link. We report the detection of circular polarization asymmetry in the electromagnetic reflection from the human skin at sub-THz frequencies in vivo. We compare the results to numerical simulations and to measurements of a fabricated metamaterial. We argue that the observed circular dichroism can be interpreted uniquely as the signature of the helical structure itself. By twisting reflected electromagnetic waves, the human skin exhibits properties which are usually discussed only in the framework of metamaterial science.

  2. Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques.

    Science.gov (United States)

    Goulet, Eric D B; Asselin, Audrey; Gosselin, Jonathan; Baker, Lindsay B

    2017-08-01

    Sweat sodium concentration (SSC) can be determined using different analytical techniques (ATs), which may have implications for athletes and scientists. This study compared the SSC measured with 5 ATs: ion chromatography (IChr), flame photometry (FP), direct (DISE) and indirect (IISE) ion-selective electrode, and ion conductivity (IC). Seventy sweat samples collected from 14 athletes were analyzed with 5 instruments: the 883 Basic IC Plus (IChr, reference instrument), AAnalyst 200 (FP), Cobas 6000 (IISE), Sweat-Chek (IC), and B-722 Laqua Twin (DISE). Instruments showed excellent relative (intraclass correlation coefficient (ICC) ≥ 0.999) and absolute (coefficient of variation (CV) ≤ 2.6%) reliability. Relative validity was also excellent between ATs (ICC ≥ 0.961). In regards to the inter-AT absolute validity, compared with IChr, standard error of the estimates were similar among ATs (2.8-3.8 mmol/L), but CV was lowest with DISE (3.9%), intermediate with IISE (7.6%), and FP (6.9%) and highest with IC (12.3%). In conclusion, SSC varies depending on the AT used to analyze samples. Therefore, results obtained from different ATs are scarcely comparable and should not be used interchangeably. Nevertheless, taking into account the normal variability in SSC (∼±12%), the imprecision of the recommendations deriving from FP, IISE, IC, and DISE should have trivial health and physiological consequences under most exercise circumstances.

  3. Textile Functionalization and Its Effects on the Release of Silver Nanoparticles into Artificial Sweat.

    Science.gov (United States)

    Wagener, Sandra; Dommershausen, Nils; Jungnickel, Harald; Laux, Peter; Mitrano, Denise; Nowack, Bernd; Schneider, Gregor; Luch, Andreas

    2016-06-07

    This study addresses the release of total silver (Ag) and silver nanoparticles (Ag-NPs) from textiles into artificial sweat, particularly considering the functionalization technology used in textile finishing. Migration experiments were conducted for four commercially available textiles and for six laboratory-prepared textiles. Two among these lab-prepared textiles represent materials in which Ag-NPs were embedded within the textile fibers (composites), whereas the other lab-prepared textiles contain Ag particles on the respective fiber surfaces (coatings). The results indicate a smaller release of total Ag from composites in comparison to surface-coated textiles. The particulate fraction determined within the artificial sweat was negligible for most textiles, meaning that the majority of the released Ag is present as dissolved Ag. It is also relevant to note that nanotextiles do not release more particulate Ag than conventional Ag textiles. The results rather indicate that the functionalization type is the most important parameter affecting the migration. Furthermore, after measuring different Ag-NP types in their pristine form with inductively coupled plasma mass spectrometry in the single particle mode, there is evidence that particle modifications, like surface coating, may also influence the dissolution behavior of the Ag-NPs in the sweat solutions. These factors are important when discussing the likelihood of consumer exposure.

  4. Vibration and Buckling of Web Plate of the Plate Girder

    OpenAIRE

    高橋, 和雄; 呉, 明強; 中澤, 聡志; 筑紫, 宏之

    1998-01-01

    The vibration and buckling of the web of the plate girder are studied in this paper. The small deflection theory of the thin plate is used. The finite strip method is employed to solve vibration and buckling of the plate girder. Natural frequenies of buckling properties are shown for various plate girder bridges.

  5. Experience with hot catchpots

    Energy Technology Data Exchange (ETDEWEB)

    1945-02-02

    The first part of this report was actually a letter regarding the question, ''could the hot circulating pump be omitted when processing pitch at 700 atm.'' It had been stated that the hot circulation pump could be omitted if the quantity of cold letdown was correspondingly increased. The latest experiences with the catchpot at Poelitz showed the following. When running pitch, tar, or petroleum in the liquid-phase stalls, frequent trouble with the hot catchpot was encountered due to the coking. This coking was caused by irregular letdown yield, which could not be avoided due to small temperature fluctuations in the stall. This caused interruption of the uniform flow in the hot catchpot and the deposition of the solids contained in the letdown, largely catalyst solids, due to the asphalt content. Coking of the product was initiated by this concentration of catalyst solids. A perforated double jacket was inserted in the conical part of the catchpot through which about 3000 m/sup 3/ per hour of cold gas was blown in continuously. By this agitation and cooling in the lowest part of the catchpot, catalyst deposits were prevented from forming and the product received a continuous added supply of hydrogen. Another letter was given discussing the same question and an alternate solution. This second letter described Welheim's design for the hot catchpot. It featured introduction of 5000 to 6000 m/sup 3//hr of cold circulating gas into the lower part of the catchpot, and withdrawal of letdown from a point above the gas inlet. The advantages were continued agitation and cooling of the sludge and constant retention of some cold sludge in the catchpot (which evened out throughput and content fluctuations)

  6. The effects of different air velocities on heat storage and body temperature in humans cycling in a hot, humid environment.

    Science.gov (United States)

    Saunders, A G; Dugas, J P; Tucker, R; Lambert, M I; Noakes, T D

    2005-03-01

    The purposes of this study were to determine (i) the effects of different facing air velocities on body temperature and heat storage during exercise in hot environmental conditions and (ii) the effects of ingesting fluids at two different rates on thermoregulation during exercise in hot conditions with higher air velocities. On five occasions nine subjects cycled for 2 h at 33.0 +/- 0.4 degrees C with a relative humidity of 59 +/- 3%. Air velocity was maintained at 0.2 km h(-1) (0 WS), 9.9 +/- 0.3 km h(-1) (10 WS), 33.3 +/-2.2 km h(-1) (100 WS) and 50.1 +/- 3.2 km h(-1) (150 WS) while subjects replaced 58.8 +/- 6.8% of sweat losses. In the fifth condition, air velocity was maintained at 33.7 +/- 2.2 km h(-1) and subjects replaced 80.0 +/- 6.8% of sweat losses (100.80 WS). Heat storage, body temperature and rating of perceived exertion were higher in 0 and 10 WS compared with all other conditions. There were no differences in any measured variable between 100 and 150 WS, or between 100 and 100.80 WS. Thus, the evaporative capacity of the environment is increased with higher air velocities, reducing heat storage and body temperature. At higher air velocities, a higher rate of fluid ingestion did not influence heat storage, body temperature or sweat rate. The finding of previous laboratory studies showing a beneficial effect of high rates of fluid ingestion on thermoregulation during exercise in hot, humid, windstill conditions cannot be extrapolated to out-of-doors exercise in which facing air velocities are seldom lower than the athlete's rate of forward progression.

  7. Appearance of D2O in sweat after oral and oral-intravenous rehydration in men.

    Science.gov (United States)

    Emmanuel, Holly; Casa, Douglas J; Beasley, Kathleen N; Lee, Elaine C; McDermott, Brendon P; Yamamoto, Linda M; Armstrong, Lawrence E; Maresh, Carl M

    2011-08-01

    Intravenous (IV) rehydration is common in athletics, but its thermoregulatory benefits and ergogenicity have not been elucidated. Availability of orally ingested fluid is dependent on gastric emptying and intestinal absorption rate. Deuterium oxide (D2O) has been used to demonstrate that fluid ingested during exercise appears in sweat within 10 minutes. The purpose of this study was to determine the effect of concurrent IV rehydration on D2O appearance in sweat samples after per ora rehydration with D2O labeled fluid. We hypothesized that the combination method would not be superior to the oral method. Ten fit men (age 23 ± 4, VO2max 59.49 ± 4.09 L·min(-1)) underwent 20 hours of fluid restriction resulting in 1.95 ± 0.25% body weight loss before beginning treadmill exercise and cycling. Exercise was performed in an environmental chamber (35.6 ± 0.2° C, 35.0 ± 1.8% relative humidity) for 2 hours at 55% VO2max, and the participants exhibited a mean body weight deficit of 4.50 ± 0.04%. Thermoregulatory measures were recorded while subjects were rehydrated with oral (OR) or oral combined with intravenous (IVO) fluid traced with D2O. After 30 minutes of rehydration and 30 minutes of seated recovery, the subjects began treadmill exercise at 55-60% VO2max. Forehead sweat samples were collected 0, 5, 10, 20, and 75 minutes from the start of rehydration. The samples were analyzed for D2O via isotope ratio mass spectrometry. D2O did not appear in the sweat within 20 minutes of rehydration; however, it did appear during the subsequent exercise bout. There was no significant difference between rehydration modes. Plasma volume increases and decreased volume of orally ingested fluid did not significantly alter transit time from ingestion to appearance in excreted sweat. The IVO method does not appear to be superior to the traditional OR method of rehydration.

  8. Hot Fuel Examination Facility (HFEF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Hot Fuel Examination Facility (HFEF) is one of the largest hot cells dedicated to radioactive materials research at Idaho National Laboratory (INL). The nation's...

  9. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  10. Potential Analysis of Thunderstorm Occurrence Using SWEAT Method at Meteorology Station Sultan Iskandar Muda

    Directory of Open Access Journals (Sweden)

    Ulfah Kurnia

    2018-01-01

    Full Text Available Salah satu hal penting dalam mengutamakan keselamatan penerbangan ialah informasi meteorologi yang tepat dan akurat terutama mengenai kondisi cuaca buruk seperti thunderstorm. Oleh karena itu, perlu dilakukan prakiraan potensi terjadinya thunderstorm, sehingga pihak maskapai penerbangan dapat menyesuaikan prosedur keselamatan baik pada saat take off, on the route, maupun landing. Pada penelitian ini dilakukan analisis data radiosonde pada 2 (dua musim, yaitu musim kemarau dan musim hujan untuk memprakirakan potensi terjadinya thunderstorm selama periode April-Desember 2016 dan Januari-Maret 2017. Data radiosonde tersebut diperoleh dari Stasiun Meteorologi Sultan Iskandar Muda yang telah diukur setiap dua kali dalam satu hari. Waktu pengukurannya ialah pada pukul 00Z dan pukul 12Z. Dengan menggunakan Software Rawinsonde Observation (RAOB versi 5.7, dilakukan pengolahan data radiosonde sehingga diperoleh informasi parameter atmosfer seperti temperatur, titik embun, dan kecepatan angin. Parameter atmosfer tersebut dapat digunakan untuk memprakirakan potensi terjadinya thunderstorm selama dua belas jam kedepan, yaitu dengan menggunakan metode SWEAT (Severe Weather Threat sehingga diperoleh SWEAT Indeks untuk setiap pengukuran radiosonde. Berdasarkan penelitian yang telah dilakukan, diketahui SWEAT Indeks untuk wilayah Stasiun Meteorologi Sultan Iskandar Muda berkisar antara 39,8 - 355,4. Hasil analisis metode SWEAT diverifikasi dengan data aktual (data synop yang diamati di Stasiun Meteorologi Sultan Iskandar Muda dan diketahui persentase kesesuaian antara data prakiraan dengan kondisi aktual yaitu 58,62-66,67%.   One of the most important things in aviation safety is the accurate information of meteorology especially on bad weather conditions as thunderstorm. Therefore, need to forecast about potential occurrence of thunderstorm, so the airlines can adjust safety aviation when take of, an the route, and landing. In this research was analysis of

  11. Tick resistance and heat tolerance characteristics in cattle. III. Sweating rate

    Directory of Open Access Journals (Sweden)

    Cecília José Veríssimo

    2012-12-01

    Full Text Available Cattle in a sustainable tropical livestock should be heat tolerant and resistant to ticks. The relationship between Rhipicephalus (Boophilus microplus infestation and sweating rate, an important heat tolerance characteristic, was studied in six Nellore and four Holstein steers of seven-month-old. They were artificial infested (a.i. with 10,000 (Holstein and 20,000 (Nellore larvae in 16/Apr/2011. In days 20, 23 and 24 after the infestation, the 10 bigger females ticks found in whole animal were weighed and put in a chamber (27 oC and 80% RH, weighing the egg mass of each female tick fourteen days after. The sweating rate (SRskin, measured by Scheleger and Turner, 1963, method, in a shaved area of shoulder skin was evaluated in 14/Apr (2 days before the a.i. and in 05/May (19 days after a.i.. In 14/Apr the Scheleger and Turner, 1963, method was done on the coat not shaved (SRcoat. The sweating rate was measured in the afternoon (from 2 P.M., after 30 minutes of direct sunlight, on April. On May, the animals remained 60 minutes in direct sunlight because this day was colder. The experimental design was a non-probability sample restricted to the 10 available animals. Data from the steers’ sweating rate were analyzed using the General linear models of the SPSS® statistical package (version 12.0 using SRskin as dependent variable and breed and sampling date as independent variables. For SRcoat breed was the independent variable. Nellore, a tropical cattle breed, had higher SRskin (1,000.82 ± 64.59 g m-2 h-1, P< 0.001 than Holstein (620.45 ± 79.10 g m-2 h-1. SRskin was higher on May (1,187.33 ± 71.49 g m-2 h-1, P< 0.001 than on April (433.93 ± 71.49 g m-2 h-1. The correlation between the two different measurements of SR was positive and significant (r= 0,545, P<0,01, Pearson correlation. But in SRcoat the breed effect disappeared because the Holstein SRcoat increased (Holstein: 884.95 ± 472.12 g m-2 h-1 and Nellore: 1,060.72 ± 318.21 g m-2 h-1

  12. The significance of hypersensitivity to autologous sweat and serum in cholinergic urticaria: cholinergic urticaria may have different subtypes.

    Science.gov (United States)

    Kim, Jung Eun; Jung, Kwan Ho; Cho, Hyun Hee; Kang, Hoon; Park, Young Min; Park, Hyun Jeong; Lee, Jun Young

    2015-07-01

    The pathogenesis of cholinergic urticaria (ChU) has been unclear except for the involvement of acetylcholine. Attempts to classify ChU according to etiology have rarely been performed. To evaluate the significance of responsiveness to autologous sweat and serum in ChU in relation to their clinical characteristics. This study involved 18 patients diagnosed with ChU between January 2010 and April 2011 in the Catholic Medical Center-St. Paul's Hospital. History taking included symptom duration, association with atopy, decreased sweat secretions, seasonal variation, and response to treatment. Intradermal autologous serum skin test (ASST) and autologous sweat skin test (ASwST) and basophil histamine release test with sweat were done. Sweat hypersensitivity was proven by a positive ASwST and basophil histamine release test in only 37.5% of patients with ChU, and in none of the healthy controls. The weal size of ASwST correlated with percentage basophil histamine release. A positive response to autologous serum was displayed by 38.9% of patients, whereas 10% of healthy controls showed a positive ASST response. Intriguingly, patients with a positive ASwST had a negative ASST, and vice versa. Despite this, there was no difference in the clinical characteristics between positive ASST and positive ASwST groups. The frequency of hypersensitivity to autologous sweat and serum was significantly higher in patients with ChU, compared with healthy controls. This suggests that autoimmunity to an unknown serum factor as well as sweat hypersensitivity may be involved in the pathogenesis of ChU. © 2014 The International Society of Dermatology.

  13. Rectal temperature, distal sweat rate, and forearm blood flow following mild exercise at two phases of the circadian cycle.

    Science.gov (United States)

    Waterhouse, Jim; Aizawa, Seika; Nevill, Alan; Edwards, Benjamin; Weinert, Dietmar; Atkinson, Greg; Reilly, Thomas

    2007-01-01

    Changes in rectal temperature during mild exercise in the middle of the rising (11:00 h) and falling (23:00 h) phases of the circadian rhythm of resting core temperature have been compared. Seven healthy males were studied at rest, while exercising on a cycle ergometer (60 min at 80 W), and during the first 30 min of recovery. Rectal temperature, forearm blood flow, and forearm sweat rate were measured at 1 min intervals throughout. During exercise, there were significant time-of-day differences in the profiles of all three variables, and in the thresholds for increases in forearm blood flow and sweating. Forearm blood flow and sweat rate were recruited more rapidly and to a greater extent with evening exercise, and rectal temperature rose less. Analysis of covariance, with rectal temperature as the covariate, indicated the associations between it and forearm blood flow or sweating were significantly different (ptimes of day. There were also significant (ptime-of-day effects for forearm blood flow and sweating that were independent of rectal temperature. During recovery, rectal temperature fell more quickly in the late evening than late morning. Forearm blood flow and sweating also showed time-of-day differences, but these did not co-vary with rectal temperature. Control of rectal temperature during exercise and recovery appears to be more effective in the late evening than late morning, and differences in forearm blood flow and sweating, as well as factors independent of these two variables, contribute to this difference. The results support our "heat-gain/heat-loss modes" hypothesis.

  14. The hot chocolate effect

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, Frank S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States)

    1982-05-01

    The "hot chocolate effect" was investigated quantitatively, using water. If a tall glass cylinder is filled nearly completely with water and tapped on the bottom with a softened mallet one can detect the lowest longitudinal mode of the water column, for which the height of the water column is one quarter wavelength. If the cylinder is rapidly filled with hot tap water containing dissolved air the pitch of that mode may descend by nearly three octaves during the first few seconds as the air comes out of solution and forms bubbles. Then the pitch gradually rises as the bubbles float to the top. A simple theoretical expression for the pitch ratio is derived and compared with experiment. The agreement is good to within the ten percent accuracy of the experiments.

  15. Diurnal rhythm and concordance between objective and subjective hot flashes: The Hilo Women’s Health Study

    Science.gov (United States)

    Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.

    2010-01-01

    Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538

  16. Evaluating formability of LCP plate for sacral fractures with one step inverse forming finite element analysis.

    Science.gov (United States)

    Li, Xiaoda; Zhang, Xiangkui; Hu, Ping; Liu, Weijie; Shen, Guozhe; Zhan, Xianghui

    2015-01-01

    The locking compression plate fixation treatment for the unstable sacral fractures is simple and effective, with less trauma and complications. Some locking compression plate parts have been made of high-strength Plate manufactured by hot stamping process since the demand for lightweight biomedical materials. Finite Element (FE) method of One-Step inverse forming based on deformation theory is the tool to evaluate the formability of locking compression plate panel quickly in initial design for reducing costs and development cycle of Plate. But current one-step inverse forming methods are all suitable for cold stamping, not hot-stamping. This paper proposed one-step inverse forming method and workflow for hot-stamping of locking compression Plate. And the B pillar of a sacral bone was simulated and its computing result was compared with experimental value. The result shows that the proposed method in this paper can quickly evaluate high temperature formability of high-strength Plate. And the method is proposed to be used in initial design.

  17. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  18. Create Your Plate

    Medline Plus

    Full Text Available ... meal-planning, In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods ... your year-end donation today and help fight diabetes. Donate Today We Can Help - we-can-help. ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... to curing diabetes and better treatments for those living with diabetes. Other Ways to Give Become a ... glucose levels and lose weight. With this method, you fill your plate with more non-starchy veggies and smaller portions of starchy foods ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... Donations Travel bookings completed through Hotels.com give 5% back to the Association. » « Connect With Us Register ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy ... Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Can I Drink? Fruit Dairy Food ...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables Fats Alcohol What Can I Drink? Fruit Dairy Food ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid ... We Can Help - we-can-help.html Chat Online Chat Closed engagement en -- Free Type 2 Education ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  8. Solar domestic hot water system installed at Texas City, Texas. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-12-01

    The Solar Energy System located at LaQuinta Motor Inn, Texas City, Texas was designed to supply 63% of the total hot water load. The Solar Energy System consists of a 2100 square foot Raypack Liquid Flat Plate Collector Subsystem and a 2500 gallon storage subsystem circulating hot water producing 3.67 x 10/sup 8/ Btu/y. Abstracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

  9. The Use of Solar Energy for Preparing Domestic Hot Water in a Multi-Storey Building

    OpenAIRE

    Giedrius Šiupšinskas; Solveiga Adomėnaitė

    2012-01-01

    The article analyses the possibilities of solar collectors used for a domestic hot water system and installed on the roofs of modernized multi-storey buildings under the existing climate conditions. A number of combinations of flat plate and vacuum solar collectors with accumulation tank systems of various sizes have been examined. Heat from the district heating system is used as an additional heat source for preparing domestic hot water. The paper compares calculation results of energy and e...

  10. Morphology of human sweat ducts observed by optical coherence tomography and their frequency of resonance in the terahertz frequency region

    Science.gov (United States)

    Tripathi, Saroj R.; Miyata, Eisuke; Ishai, Paul Ben; Kawase, Kodo

    2015-03-01

    It is crucial to understand the various biological effects induced by terahertz (THz) electromagnetic waves with the rapid development of electronic and photonic devices operating in the THz frequency region. The presence of sweat glands plays an important role in THz wave interactions with human skin. We investigated the morphological features of sweat ducts using optical coherence tomography (OCT) to further understand such phenomena. We observed remarkable features of the ducts, such as their clear helical structure. The intersubject and intrasubject variations in the diameter of sweat ducts were considerably smaller than the variations in other structural parameters, such as length and number of turns. Based on the sweat duct dimensions and THz dielectric properties of skin measured using terahertz time-domain spectroscopy (THz-TDS), we calculated the resonating frequency of the sweat duct under the assumption of it functioning as a helical antenna. Here, we show that the resonance frequency in the axial mode of operation lies in the THz wave region with a centre frequency of 0.44 +/- 0.07 THz. We expect that these findings will further our understanding of the various health consequences of the interaction of THz waves with human beings.

  11. 2nd dimensional GC-MS analysis of sweat volatile organic compounds prepared by solid phase micro-extraction.

    Science.gov (United States)

    Choi, Mi-Jung; Oh, Chang-Hwan

    2014-01-01

    The characteristics of an individual's odor from sweat, breath and skin provide important information for criminal tracking in field of forensic science. Solid phase micro-extraction gas chromatography/mass spectrometry (SPME-GC/MS) was used to determine human sweat volatile organic compounds (VOCs) profiles. The mass spectrometric analysis (with electron impact mode) followed by 2nd dimensional separation with two different GC columns (one polar and one relatively nonpolar) connected in parallel were used to identify the 574 compounds from sweat samples. The components included alcohols, aldehydes, aliphatics/aromatics, carboxylic acids, esters, ketones, and other organic compounds (amides/amines, thio/thioesters, oxide, sulfides, nitro compounds). Of these compounds, 1-tridecanol, 1,3-bis(1,1-dimethyl ethyl)-benzene, 4,4'-(1-methylethylidene) bis-phenol and 7-acetyl-6-ethyl-1,1,4,4,-tetramethyl-tetraline were common components in all donor's sweat volatile samples. Age-related specific compounds were also detected. The results suggest that characteristic volatile profiles of human sweat emanations could provide the valuable information to forensic scientists.

  12. A new method of artificial latent fingerprint creation using artificial sweat and inkjet printer.

    Science.gov (United States)

    Hong, Sungwook; Hong, Ingi; Han, Aleum; Seo, Jin Yi; Namgung, Juyoung

    2015-12-01

    In order to study fingerprinting in the field of forensic science, it is very important to have two or more latent fingerprints with identical chemical composition and intensity. However, it is impossible to obtain identical fingerprints, in reality, because fingerprinting comes out slightly differently every time. A previous research study had proposed an artificial fingerprint creation method in which inkjet ink was replaced with amino acids and sodium chloride solution: the components of human sweat. But, this method had some drawbacks: divalent cations were not added while formulating the artificial sweat solution, and diluted solutions were used for creating weakly deposited latent fingerprint. In this study, a method was developed for overcoming the drawbacks of the methods used in the previous study. Several divalent cations were added in this study because the amino acid-ninhydrin (or some of its analogues) complex is known to react with divalent cations to produce a photoluminescent product; and, similarly, the amino acid-1,2-indanedione complex is known to be catalyzed by a small amount of zinc ions to produce a highly photoluminescent product. Also, in this study, a new technique was developed which enables to adjust the intensity when printing the latent fingerprint patterns. In this method, image processing software is used to control the intensity of the master fingerprint patterns, which adjusts the printing intensity of the latent fingerprints. This new method opened the way to produce a more realistic artificial fingerprint in various strengths with one artificial sweat working solution. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Luteal phase of the menstrual cycle increases sweating rate during exercise

    Directory of Open Access Journals (Sweden)

    Garcia A.M.C.

    2006-01-01

    Full Text Available The present study evaluated whether the luteal phase elevation of body temperature would be offset during exercise by increased sweating, when women are normally hydrated. Eleven women performed 60 min of cycling exercise at 60% of their maximal work load at 32ºC and 80% relative air humidity. Each subject participated in two identical experimental sessions: one during the follicular phase (between days 5 and 8 and the other during the luteal phase (between days 22 and 25. Women with serum progesterone >3 ng/mL, in the luteal phase were classified as group 1 (N = 4, whereas the others were classified as group 2 (N = 7. Post-exercise urine volume (213 ± 80 vs 309 ± 113 mL and specific urine gravity (1.008 ± 0.003 vs 1.006 ± 0.002 changed (P < 0.05 during the luteal phase compared to the follicular phase in group 1. No menstrual cycle dependence was observed for these parameters in group 2. Sweat rate was higher (P < 0.05 in the luteal (3.10 ± 0.81 g m-2 min-1 than in the follicular phase (2.80 ± 0.64 g m-2 min-1 only in group 1. During exercise, no differences related to menstrual cycle phases were seen in rectal temperature, heart rate, rate of perceived exertion, mean skin temperature, and pre- and post-exercise body weight. Women exercising in a warm and humid environment with water intake seem to be able to adapt to the luteal phase increase of basal body temperature through reduced urinary volume and increased sweating rate.

  14. Evaporimeter and Bubble-Imaging Measures of Sweat Gland Secretion Rates.

    Science.gov (United States)

    Kim, Jeeyeon; Farahmand, Miesha; Dunn, Colleen; Davies, Zoe; Frisbee, Eric; Milla, Carlos; Wine, Jeffrey J

    2016-01-01

    Beta-adrenergically-stimulated sweat rates determined by evaporimetry or by sweat bubble imaging are useful for measuring CFTR function because they provide a near-linear readout across almost the full range of CFTR function. They differentiate cystic fibrosis (CF) subjects from CF carriers and carriers from controls. However, evaporimetry, unlike bubble imaging, appears to be unable to detect improved levels of CFTR function in G551D subjects taking the CFTR modulator ivacaftor. Here, we quantify the sensitivity of evaporimetry and bubble imaging methods for assessing low levels of CFTR-dependent sweat rates. To establish sensitivity, we did dose-ranging studies using intradermally injected [cAMP]i-elevating cocktails. We reduced isoproterenol/aminophylline levels while maintaining a high level of atropine to block muscarinic elevation of [Ca2+]i. We stimulated the same sets of glands for both assays and recorded responses for 20 min. In response to a 3-log dilution of the stimulating cocktail (0.1%), bubble responses were detected in 12/12 tests (100%), with 49% ± 3% of glands secreting to produce an aggregate volume of 598 nl across the 12, 20-min tests. This was ~5% of the response to full cocktail. Evaporimetry detected responses in 3/12 (25%) tests with an aggregate secretion volume of 175 nl. After stimulation with a still more dilute cocktail (0.03%), bubble imaging detected 15 ± 13% of glands secreting at a rate ~0.9% of the response to full cocktail, while zero responding was seen with evaporimetry. The bubble imaging method detected secretion down to aggregate rates of bubble imaging may be required to detect small but physiologically important increases in secretion rates produced by CFTR modulators.

  15. Electrochemical behaviour of brass in chloride solution concentrations found in eccrine fingerprint sweat

    Energy Technology Data Exchange (ETDEWEB)

    Bond, John W., E-mail: jwb13@le.ac.uk [Department of Chemistry, George Porter Building, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Lieu, Elaine [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom)

    2014-09-15

    Highlights: • Corrosion of brass in NaCl concentrations found in eccrine sweat was investigated. • Concentrations < 0.2 M produce a layer of mainly zinc oxide after 24 h. • A concentration of 0.2 M enables active corrosion of brass at room temperature. • 0.2 M NaCl gives both zinc and copper dissolution. • 24-h immersion of brass in 0.2 M NaCl gives an oxide film thickness of 1.3 nm. - Abstract: In this work, the corrosion properties of α phase brass immersed in concentrations of aqueous NaCl solutions that are typically found in eccrine fingerprint sweat and range between 0.01 M and 0.2 M have been analysed. Analysis methods employed were electrochemical techniques, X-ray photoelectron spectroscopy and optical profiling. For NaCl concentrations <0.2 M, active corrosion did not occur although, after a period of 24 h, a passivating layer of mainly zinc oxide formed. At a concentration of 0.2 M active corrosion did occur, with measured corrosion potentials consistent with both brass and copper dissolution. A 1 h contact time at this concentration (0.2 M) resulted in the formation of a zinc oxide passivating layer with the surface ratio of zinc oxide to copper oxide increasing with time. Film thickness was calculated to be of the order of 1.3 nm after 24 h contact. Formation of oxide layers on brass by fingerprint sweat as observed here may well have implications for the successful investigation of crime by the visualisation of corrosion fingerprint ridge patterns or the reduction of hospital environmental contamination by hand contact with brass objects such as door handles or taps.

  16. Luteal phase of the menstrual cycle increases sweating rate during exercise

    Directory of Open Access Journals (Sweden)

    A.M.C. Garcia

    Full Text Available The present study evaluated whether the luteal phase elevation of body temperature would be offset during exercise by increased sweating, when women are normally hydrated. Eleven women performed 60 min of cycling exercise at 60% of their maximal work load at 32ºC and 80% relative air humidity. Each subject participated in two identical experimental sessions: one during the follicular phase (between days 5 and 8 and the other during the luteal phase (between days 22 and 25. Women with serum progesterone >3 ng/mL, in the luteal phase were classified as group 1 (N = 4, whereas the others were classified as group 2 (N = 7. Post-exercise urine volume (213 ± 80 vs 309 ± 113 mL and specific urine gravity (1.008 ± 0.003 vs 1.006 ± 0.002 changed (P < 0.05 during the luteal phase compared to the follicular phase in group 1. No menstrual cycle dependence was observed for these parameters in group 2. Sweat rate was higher (P < 0.05 in the luteal (3.10 ± 0.81 g m-2 min-1 than in the follicular phase (2.80 ± 0.64 g m-2 min-1 only in group 1. During exercise, no differences related to menstrual cycle phases were seen in rectal temperature, heart rate, rate of perceived exertion, mean skin temperature, and pre- and post-exercise body weight. Women exercising in a warm and humid environment with water intake seem to be able to adapt to the luteal phase increase of basal body temperature through reduced urinary volume and increased sweating rate.

  17. Maintenance of sweat glands by stem cells located in the acral epithelium

    Energy Technology Data Exchange (ETDEWEB)

    Ohe, Shuichi [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Dermatology, Kansai Medical University, Osaka 573-1010 (Japan); Tanaka, Toshihiro [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Third Department of Internal Medicine, Kansai Medical University, Osaka 573-1010 (Japan); Yanai, Hirotsugu [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Surgery, Kansai Medical University, Osaka 573-1010 (Japan); Komai, Yoshihiro [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Urology and Andrology, Kansai Medical University, Osaka 573-1010 (Japan); Omachi, Taichi [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Pediatrics, Kansai Medical University, Osaka 573-1010 (Japan); Kanno, Shohei; Tanaka, Kiyomichi; Ishigaki, Kazuhiko; Saiga, Kazuho [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Nakamura, Naohiro [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Third Department of Internal Medicine, Kansai Medical University, Osaka 573-1010 (Japan); Ohsugi, Haruyuki [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Department of Urology and Andrology, Kansai Medical University, Osaka 573-1010 (Japan); Tokuyama, Yoko; Atsumi, Naho; Hisha, Hiroko; Yoshida, Naoko; Kumano, Keiki [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan); Yamazaki, Fumikazu; Okamoto, Hiroyuki [Department of Dermatology, Kansai Medical University, Osaka 573-1010 (Japan); Ueno, Hiroo, E-mail: hueno@hirakata.kmu.ac.jp [Department of Stem Cell Pathology, Kansai Medical University, Osaka 573-1010 (Japan)

    2015-10-23

    The skin is responsible for a variety of physiological functions and is critical for wound healing and repair. Therefore, the regenerative capacity of the skin is important. However, stem cells responsible for maintaining the acral epithelium had not previously been identified. In this study, we identified the specific stem cells in the acral epithelium that participate in the long-term maintenance of sweat glands, ducts, and interadnexal epidermis and that facilitate the regeneration of these structures following injury. Lgr6-positive cells and Bmi1-positive cells were found to function as long-term multipotent stem cells that maintained the entire eccrine unit and the interadnexal epidermis. However, while Lgr6-positive cells were rapidly cycled and constantly supplied differentiated cells, Bmi1-positive cells were slow to cycle and occasionally entered the cell cycle under physiological conditions. Upon irradiation-induced injury, Bmi1-positive cells rapidly proliferated and regenerated injured epithelial tissue. Therefore, Bmi1-positive stem cells served as reservoir stem cells. Lgr5-positive cells were rapidly cycled and maintained only sweat glands; therefore, we concluded that these cells functioned as lineage-restricted progenitors. Taken together, our data demonstrated the identification of stem cells that maintained the entire acral epithelium and supported the different roles of three cellular classes. - Highlights: • The acral epithelium have two types of stem cells. • Lgr6-positive cells are rapid-cycling, short-term stem cells. • Bmi1-positive cells are slow-cycling stem cells that act as reserver stem cells. • Lgr5 may be a useful sweat gland marker in mice.

  18. Acupuncture and traditional Chinese medicine for hot flushes in menopause: a randomized trial.

    Science.gov (United States)

    Baccetti, Sonia; Da Frè, Monica; Becorpi, Angelamaria; Faedda, Marina; Guerrera, Antonella; Monechi, M Valeria; Munizzi, Rosa Maria; Parazzini, Fabio

    2014-07-01

    To evaluate the effect of acupuncture on hot flushes and other menopause-related symptoms used in an integrated system, including such therapeutic techniques as diet therapy and Tuina self-massage. Randomized trial. Outpatient center. One hundred women in spontaneous menopause with at least three episodes of hot flushes daily were randomly allocated to two treatment groups (50 per group): Women in group A were given diet, self-massage training, and treatment with acupuncture, and women in group B (the control group) were given the same diet and self-massage training, but treatment with acupuncture started 6 weeks after they were enrolled into the study. Acupuncture treatments were scheduled twice weekly for 6 consecutive weeks. Mean change in frequency and/or intensity in menopause-related symptoms were estimated by questionnaire after treatment at week 4. Treatment with acupuncture significantly reduced the occurrence of hot flushes and sudden sweating (pAcupuncture in an integrated system that includes therapeutic techniques such as diet therapy and Tuina self-massage can be used to treat hot flushes and selected symptoms in postmenopausal women.

  19. Potential role of gabapentin and extended- release gabapentin in the management of menopausal hot flashes

    Directory of Open Access Journals (Sweden)

    Yadav M

    2013-08-01

    Full Text Available Manisha Yadav, Judith Volkar Center for Specialized Women’s Health, Cleveland Clinic Foundation, Cleveland, Ohio, USA Abstract: About 80% of postmenopausal women experience vasomotor symptoms, such as hot flashes and night sweats – symptoms that are associated with sleep disruption and can lead to fatigue and mood changes. Moreover, hot flashes can be embarrassing for women, causing difficulties at work and in their social lives. Many therapies have been advocated for relief of vasomotor symptoms, but only hormone therapy has been US Food and Drug Administration approved. However, after the Women's Health Initiative Study suggested that there was a correlation between hormone therapy and increased risk for breast cancer and cardiovascular events, many women stopped taking hormone therapy, and many do not want to initiate it. Hormone therapy is also contraindicated in certain women, such as those with a history of hormone-stimulated cancer like breast and uterine cancer. Gabapentin (Neurontin has shown efficacy in relieving vasomotor symptoms and is used as off-label for this indication. A new extended-release formulation of gabapentin has also shown efficacy in treating hot flashes and improving sleep quality with possibly fewer side effects than regular gabapentin. Keywords: Hot flushes, vasomotor symptoms, postmenopausal, hormone-sensitive cancer, non-hormonal therapy, gastric-retentive, Breeze

  20. Evaluation of fluid intake, weight loss and sweat rate in young triathletes

    Directory of Open Access Journals (Sweden)

    María Cristina Sellés López de Castro

    2015-10-01

    Full Text Available Introduction: Triathlon is an endurance sport comprising three disciplines: swimming, cycling and running. It is necessary to purpose guidelines in order to avoid dehydration during training or competition and keep good hydration before, during and after physical activity. The aim of this study is to evaluation of fluid intake, weight loss and sweat rate in young triathletes, during different trainings.Material and Methods: A descriptive-observational study in 14 triathletes (7 boys and 7 girls during a session of swimming, other session of cycling, another session of running. Fluid intake, weight loss, % of total body water, % dehydration and sweat rate, were assessed. Triathletes drank water in their drums of 750 ml and urine measurement was performed in containers.Results: The results of our study following the next order: swimming, cycling and running. Water intake 2.66±1.94ml/min, 7.91±7.69ml/min y 7.08±4.13ml/min in boys and 3.43±1.53ml/min, 6.39±5.36ml/min y 8.33±2.74ml/min in girls; weight loss 0.83±0.5kg, 0.47±0.3kg y 0.98±0.4kg in boys and 0.79±0.3kg, 0.47±0.58kg y 0.28±0.21kg in girls; and sweating rate 4.44±4.9ml/ min, 11.81±6.46ml/min y 5.29±3.13ml/min in boys and 3.89±2.4ml/min, 4.69±4.20ml/min and 7.96±5.06ml/min in girls.Conclusions: The percentage of body water and dehydration, loss of weight and sweat rate were compared with other studies and it´s shown that our results are lower than others studies, being below the recommendations of liquid intake in athletes.