WorldWideScience

Sample records for swales converting turf

  1. Compost-amended biofiltration swale evaluation.

    Science.gov (United States)

    2011-09-01

    From May 2009 through June 2010, Herrera Environmental Consultants conducted hydrologic : and water quality monitoring of a compost-amended biofiltration swale and a standard (control) : biofiltration swale in the median of State Route 518 for the Wa...

  2. EAP, Business English and Swales' approach to genre analysis

    OpenAIRE

    Revilla Vicente, Rosa

    2008-01-01

    One of the most influential genre scholars is John Swales. His 1990 book Genre Analysis is a point of reference in the field and he is considered one of the most widely respected and cited researchers. The aim of this article is to demonstrate how John Swales' approach to genre analysis, which was originally designed to research English in academic and research settings, can al so be used for the textual analysis of occupational genres. The theory he develops in his latest two books (1990, 20...

  3. PIXE Analysis of Artificial Turf

    Science.gov (United States)

    Conlan, Skye; Chalise, Sajju; Porat, Zachary; Labrake, Scott; Vineyard, Michael

    2017-09-01

    In recent years, there has been debate regarding the use of the crumb rubber infill in artificial turf on high school and college campuses due to the potential presence of heavy metals and carcinogenic chemicals. We performed Proton-Induced X-Ray Emission (PIXE) analysis of artificial turf infill and blade samples collected from high school and college campuses around the Capital District of NYS to search for potentially toxic substances. Crumb rubber pellets were made by mixing 1g of rubber infill and 1g of epoxy. The pellets and the turf blades were bombarded with 2.2 MeV proton beams from a 1.1-MV tandem Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory and x-ray energy spectra were collected with an Amptek silicon drift detector. We analyzed the spectra using GUPIX software to determine the elemental concentrations of the samples. The turf infill showed significant levels of Ti, Fe, Co, Ni, Cu, Zn, Br, and Pb. The highest concentration of Br in the crumb rubber was 1500 +/-100 ppm while the highest detectable amount of Pb concentration was 110 +/-20 ppm. The artificial turf blades showed significant levels of Ti, Fe, and Zn with only the yellow blade showing concentrations of V and Bi.

  4. Pollutant Removal and Hydraulic Reduction Performance of Field Grassed Swales during Runoff Simulation Experiments

    National Research Council Canada - National Science Library

    Terry Lucke; Mohamed Ansaf Kachchu Mohamed; Neil Tindale

    2014-01-01

      Four different field swales were tested in this study, using 24 standardised synthetic runoff simulation experiments to evaluate their performance in removing Total Suspended Solids (TSS), Total Nitrogen (TN...

  5. A review of football injuries on third and fourth generation artificial turfs compared with natural turf.

    Science.gov (United States)

    Williams, Sean; Hume, Patria A; Kara, Stephen

    2011-11-01

    Football codes (rugby union, soccer, American football) train and play matches on natural and artificial turfs. A review of injuries on different turfs was needed to inform practitioners and sporting bodies on turf-related injury mechanisms and risk factors. Therefore, the aim of this review was to compare the incidence, nature and mechanisms of injuries sustained on newer generation artificial turfs and natural turfs. Electronic databases were searched using the keywords 'artificial turf', 'natural turf', 'grass' and 'inj*'. Delimitation of 120 articles sourced to those addressing injuries in football codes and those using third and fourth generation artificial turfs or natural turfs resulted in 11 experimental papers. These 11 papers provided 20 cohorts that could be assessed using magnitude-based inferences for injury incidence rate ratio calculations pertaining to differences between surfaces. Analysis showed that 16 of the 20 cohorts showed trivial effects for overall incidence rate ratios between surfaces. There was increased risk of ankle injury playing on artificial turf in eight cohorts, with incidence rate ratios from 0.7 to 5.2. Evidence concerning risk of knee injuries on the two surfaces was inconsistent, with incidence rate ratios from 0.4 to 2.8. Two cohorts showed beneficial inferences over the 90% likelihood value for effects of artificial surface on muscle injuries for soccer players; however, there were also two harmful, four unclear and five trivial inferences across the three football codes. Inferences relating to injury severity were inconsistent, with the exception that artificial turf was very likely to have harmful effects for minor injuries in rugby union training and severe injuries in young female soccer players. No clear differences between surfaces were evident in relation to training versus match injuries. Potential mechanisms for differing injury patterns on artificial turf compared with natural turf include increased peak torque and

  6. Laboratory based experiments to assess the use of green and food based compost to improve water quality in a Sustainable Drainage (SUDS) device such as a swale.

    Science.gov (United States)

    Charlesworth, S M; Nnadi, E; Oyelola, O; Bennett, J; Warwick, F; Jackson, R; Lawson, D

    2012-05-01

    Many tonnes of compost are generated per year due to door step composting of both garden and kitchen waste. Whilst there are commercial outlets for the finer grade of compost (nurseries, there is little demand for the coarser material (>25 mm). This paper reports part of a WRAP-sponsored (Waste Resources Action Programme) study which investigated the potential for green (GC) and mixed green and food (MC) composts to be incorporated into Sustainable Drainage (SUDS) devices such as swales, and replace the topsoil (TS) onto which turf is laid or grass seed distributed. However, it is not known whether compost can replace TS in terms of pollutant remediation, both the trapping of polluted particulates and in dealing with hydrocarbons such as oil, but also from a biofilm development and activity perspective. Using laboratory based experiments utilising leaching columns and an investigation of microbiological development in the composts studied, it was found that many of the differences in performance between MC and GC were insignificant, whilst both composts performed better in terms of pollutant retention than TS. Mixed compost in particular could be used in devices where there may be oil spillages, such as the lorry park of a Motorway Service Area due to its efficiency in degrading oil. Samples of GC and MC were found to contain many of the bacteria and fungi necessary for an active and efficient biofilm which would be an argument in their favour for replacement of TS and incorporation in swales. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Performance of infiltration swales with regard to operation in winter times in an Alpine region.

    Science.gov (United States)

    Fach, Stefan; Engelhard, Carolina; Wittke, Nina; Rauch, Wolfgang

    2011-01-01

    In cold climate regions winter conditions significantly influence the performance of stormwater infiltration devices. Frozen soil and water storage by snow changes their operation. In this paper winter operation of a grassed infiltration swale was investigated using on-site and laboratory measurements. The field investigation of a grassed swale at a parking place in an Alpine region showed that the swale fulfilled its function properly. Although the top layer was frozen for some time, the storage capacity of the swale was sufficient to store the precipitation until the conditions improved. The soil attenuated the air temperature, at 20 cm below ground surface the soil was only frozen for one week. winter maintenance proved to be a problem, together with the snow from the parking place a lot of gravel and fine particles were deposited at one end of the swale. This decreased the hydraulic conductivity at that point significantly. The laboratory tests with soil columns showed an increase of flow time through the soil column with decreasing soil moisture content. For soil temperatures below 0 degrees C the hydraulic conductivity was reduced for increasing initial soil moisture contents. All in all the hydraulic conductivity was best around 0 degrees C for all soil water contents. However, also at minus 5 degrees C the coefficient of hydraulic conductivity was always at least above 10(-6) m/s, thus within the range of tolerated hydraulic conductivity specified in the national guidelines. Nevertheless, the handling of the soil was found to have high influence on the results. The results indicate that in the Alpine region infiltration swales operate sufficiently under winter conditions although with decreased performance.

  8. A very Freudian affair: Erich Fromm, Peter Swales and the future of psychoanalytic historiography.

    Science.gov (United States)

    Burston, Daniel

    2008-01-01

    Despite steadfast denials by Ernest Jones, Peter Gay and Paul Roazen (among others), a recent discovery by Franz Maciejewski renders it reasonably certain that Freud had an affair with his sister-in-law, Minna Bernays. While this discovery vindicates certain claims made by the controversial Freud scholar, Peter Swales, other claims of his vis-a-vis Freud's personality and ideas are open to doubt. Meanwhile, the reception of Swales's ideas, and indeed the whole controversy about Freud's love life, provide ample confirmation of many of Erich Fromm's prescient theses about Freud's personality and the politics and historiography of psychoanalysis.

  9. Ornamental and Turf Pest Control. Bulletin 764.

    Science.gov (United States)

    Bowyer, Timothy H.; And Others

    This manual gives descriptions of and methods for control of diseases and insect pests of ornamental plants, weeds, and diseases and insect pests of turf plants. Included are diseases caused by fungi such as cankers, leaf galls, and rust; diseases caused by bacteria such as bacterial blight and crown gall; and diseases caused by nematodes and…

  10. Thermophysics Universal Research Framework (TURF) Tutorial Package

    Science.gov (United States)

    2017-03-02

    Currently, the set of elliptic solvers in TURF is relatively minimal and includes only red-black Gauss-Seidel and tri-diagonal ADI-type solvers as...noisy. The agreement between the two codes was very reasonable considering all the particle trajectories are coupled to the field solution and vice...conditions for our domain; particles continue on their trajectory beyond the bounds of the simulation. Fig. 1. The final state of the helium particles

  11. Natural turf surfaces: the case for continued research.

    Science.gov (United States)

    Stiles, Victoria H; James, Iain T; Dixon, Sharon J; Guisasola, Igor N

    2009-01-01

    It is well documented that health and social benefits can be attained through participation in sport and exercise. Participation, particularly in sports, benefits from appropriate surface provisions that are safe, affordable and high quality preferably across the recreational to elite continuum. Investment, construction and research into artificial sports surfaces have increased to meet this provision. However, not all sports (e.g. golf, rugby and cricket) are suited to training and match-play on artificial turf without compromising some playing characteristics of the games. Therefore, full sport surface provision cannot be met without the use of natural turf surfaces, which also have an important role as green spaces in the built environment. Furthermore, a significant number of people participate in outdoor sport on natural turf pitches, although this is a declining trend as the number of synthetic turf surfaces increases. Despite natural turf being a common playing surface for popular sports such as soccer, rugby and cricket, few biomechanical studies have been performed using natural turf conditions. It is proposed that if natural turf surfaces are to help meet the provision of sports surfaces, advancement in the construction and sustainability of natural turf surface design is required. The design of a natural turf surface should also be informed by knowledge of surface-related overuse injury risk factors. This article reviews biomechanical, engineering, soil mechanics, turfgrass science, sports medicine and injury-related literature with a view to proposing a multidisciplinary approach to engineering a more sustainable natural turf sport surface. The present article concludes that an integrated approach incorporating an engineering and biomechanical analysis of the effects of variations in natural turf media on human movement and the effects of variations in human movement on natural turf is primarily required to address the longer-term development of

  12. Study on Storm-Water Management of Grassed Swales and Permeable Pavement Based on SWMM

    Directory of Open Access Journals (Sweden)

    Jianguang Xie

    2017-10-01

    Full Text Available Grassed swales and permeable pavement that have greater permeable underlying surface relative to hard-pressing surface can cooperate with the city pipe network on participating in urban storm flood regulation. This paper took Nanshan village in Jiangsu Province as an example, the storm-water management model (SWMM was used to conceptualize the study area reasonably, and the low-impact development (LID model and the traditional development model were established in the region. Based on the storm-intensity equation, the simulation scene employed the Chicago hydrograph model to synthesize different rainfall scenes with different rainfall repetition periods, and then contrasted the storm-flood-management effect of the two models under the condition of using LID facilities. The results showed that when the rainfall repetition period ranged from 0.33a to 10a (a refers to the rainfall repetition period, the reduction rate of total runoff in the research area that adopted LID ranged from 100% to 27.5%, while the reduction rate of peak flow ranged from 100% to 15.9%, and when the values of unit area were the same, the combined system (permeable pavement + grassed swales worked more efficiently than the sum of the individuals in the reduction of total runoff and peak flow throughout. This research can provide technical support and theoretical basis for urban LID design.

  13. Risk assessment of pesticide runoff from turf.

    Science.gov (United States)

    Haith, Douglas A; Rossi, Frank S

    2003-01-01

    The TurfPQ model was used to simulate the runoff of 15 pesticides commonly applied to creeping bentgrass (Agrostis stolonifera L.) fairways and greens on golf courses in the northeastern USA. Simulations produced 100-yr daily records of water runoff, pesticide runoff, and pesticide concentration in runoff for three locations: Boston, MA, Philadelphia, PA, and Rochester, NY. Results were summarized as annual and monthly means and annual maximum daily loads (AMDLs) corresponding to 10- and 20-yr return periods. Mean annual pesticide runoff loads did not exceed 3% of annual applications for any pesticide or site, and most losses were substantially less than 1% of application. However, annual or monthly mean concentrations of chlorothalonil, iprodione, and PCNB in fairway runoff often exceeded concentrations that result in 50% mortality of the affected species (LC50) for aquatic organisms. Concentrations of azoxystrobin, bensulide, cyfluthrin, and trichlorfon in extreme (1 in 10 yr or 1 in 20 yr) events often approached or exceeded LC50 levels. Concentrations of halofenozide, mancozeb, MCPP, oxadiazon, propiconazole, thiophanate-methyl, triadimefon, and trinexapac-ethyl were well below LC50 levels, and turf runoff of these chemicals does not appear to be hazardous to aquatic life in surface waters.

  14. From Star Wars to 'turf wars'.

    Science.gov (United States)

    1999-09-01

    Just as we are witnessing the re-emergence of Star Wars, it seems the 'turf wars' that have dogged A&E care are back. Since its inception as a specialty, A&E nurses have been accused of being 'Jacks (and Jill's, to be politically correct) of all trades and masters of none'. The inference being that all we do is 'mind' patients until they receive definitive care. Clearly this is not the case. As A&E nurses have demonstrated over the years, our skills are in the recognition and management of acute illness or injury, regardless of the patient's age, physical or psychological condition. Rather than being a 'master of none' we are masters of immediate care.

  15. Lawn and Turf Pest Control: A Guide for Commercial Applicators.

    Science.gov (United States)

    Khan, M. S.

    This manual is designed for use in training commercial pesticide applicators. It gives identification and control information for common lawn and turf diseases, insects, nematodes, weeds, and vertebrate pests. It also discusses phytotoxicity, environmental concerns, and application methods. (BB)

  16. Three-Dimensional Investigation of a 5 m Deflected Swale along the San Andreas Fault in the Carrizo Plain

    KAUST Repository

    Akciz, S. O.

    2014-10-21

    Topographic maps produced from Light Detection and Ranging (LiDAR) data are useful for paleoseismic and neotectonic research because they provide submeter representation of faulting-related surface features. Offset measurements of geomorphic features, made in the field or on a remotely sensed imagery, commonly assume a straight or smooth (i.e., undeflected) pre-earthquake geometry. Here, we present results from investigation of an ∼20 cm deep and >5 m wide swale with a sharp bend along the San Andreas fault (SAF) at the Bidart fan site in the Carrizo Plain, California. From analysis of LiDAR topography images and field measurements, the swale was initially interpreted as a channel tectonically offset ∼4:7 m. Our observations from exposures in four backhoe excavations and 25 hand-dug trenchettes show that even though a sharp bend in the swale coincides with the trace of the A.D. 1857 fault rupture, the swale formed after the 1857 earthquake and was not tectonically offset. Subtle fractures observed within a surficial gravel unit overlying the 1857 rupture trace are similar to fractures previously documented at the Phelan fan and LY4 paleoseismic sites 3 and 35 km northwest of Bidart fan, respectively. Collectively, the fractures suggest that a post-1857 moderate-magnitude earthquake caused ground cracking in the Carrizo and Cholame stretches of the SAF. Our observations emphasize the importance of excavation at key locations to validate remote and ground-based measurements, and we advocate more geomorphic characterization for each site if excavation is not possible.

  17. Assessment of Biosorption Activated Media Under Roadside Swales for the Removal of Phosphorus from Stormwater

    Directory of Open Access Journals (Sweden)

    Andrew Hood

    2013-01-01

    Full Text Available Stormwater runoff from highways is a source of pollution to surface water bodies and groundwater. Excess loadings of phosphorus in stormwater discharged to surface water bodies can result in eutrophication. Treatment of stormwater for phosphorus is necessary in order to sustain ecological and economical benefits related to aquatic resources. If phosphorus is removed, the water can be sustained for other uses, such as irrigation and industrial applications. The data presented in this paper is used to evaluate the treatment performance of a roadside biosorption activated media system with regards to the removal of total phosphorus and soluble reactive phosphorus from highway runoff. The evaluation also compares removal efficiencies and effluent concentrations using biosorption activated media (BAM to that with sandy soil commonly found in the Florida area. The results presented in this paper indicate that BAM bio-filtration systems are a feasible treatment method for removing phosphorus from highway runoff. A discussion concerning the additional treatment and reuse of water by harvesting, as part of a Bio-filtration & Harvesting Swale System, is also presented in the paper.

  18. Simulation of Rainfall-Runoff Response in Ecological Swale with On-Line Subsurface Detention Using Infoworks SD.

    Science.gov (United States)

    Ghadim, Hamed Benisi; Hin, Lai Sai

    2017-09-01

      The Bio-Ecological Drainage System (BIOECODS) is a sustainable drainage (SUDS) to demonstrate the 'control at source' approaches for urban stormwater management in Malaysia. It is an environmentally friendly drainage system that was designed to increase infiltration, reduce peak flow at outlet, improve water quality, through different BMPs, such as grass swale, retention pond, etc. A special feature of BIOECODS is ecological swale with on-line subsurface detention. This study attempted to create a model of ecological swale with on-line subsurface conveyance system with InfoWorks SD. The new technique has been used Storm Water Management Model (SWMM) model to describe overland flow routing and Soil Conservation Service Method (SCS) used to model infiltration or subsurface flow. The modeling technique has been proven successful, as the predicted and observed closely match each other, with a mean error of 4.58 to 7.32%. The calibrated model then used to determine the ratio of the flow exchange between the surface and subsurface drainage system. Results from the model showed that the runoff ratio exchange between the surface and subsurface is 60 to 90%.

  19. Competitive interactions between corals and turf algae depend on coral colony form

    NARCIS (Netherlands)

    Swierts, T.; Vermeij, M.J.A.

    2016-01-01

    Turf algae are becoming more abundant on coral reefs worldwide, but their effects on other benthic organisms remain poorly described. To describe the general characteristics of competitive interactions between corals and turf algae, we determined the occurrence and outcomes of coral–turf algal

  20. Competitive interactions between corals and turf algae depend on coral colony form.

    Science.gov (United States)

    Swierts, Thomas; Vermeij, Mark Ja

    2016-01-01

    Turf algae are becoming more abundant on coral reefs worldwide, but their effects on other benthic organisms remain poorly described. To describe the general characteristics of competitive interactions between corals and turf algae, we determined the occurrence and outcomes of coral-turf algal interactions among different coral growth forms (branching, upright, massive, encrusting, plating, and solitary) on a shallow reef in Vietnam. In total, the amount of turf algal interaction, i.e., the proportion of the coral boundary directly bordering turf algae, was quantified for 1,276 coral colonies belonging to 27 genera and the putative outcome of each interaction was noted. The amount of turf algal interaction and the outcome of these interactions differed predictably among the six growth forms. Encrusting corals interacted most often with turf algae, but also competed most successfully against turf algae. The opposite was observed for branching corals, which rarely interacted with turf algae and rarely won these competitive interactions. Including all other growth forms, a positive relationship was found between the amount of competitive interactions with neighboring turf algae and the percentage of such interaction won by the coral. This growth form dependent ability to outcompete turf algae was not only observed among coral species, but also among different growth forms in morphologically plastic coral genera (Acropora, Favia, Favites, Montastrea, Montipora, Porites) illustrating the general nature of this relationship.

  1. In vitro chemical mutagenesis improves the turf quality of bahiagrass

    NARCIS (Netherlands)

    Kannan, Baskaran; Davila Olivas, N.H.; Lomba, Paula; Altpeter, Fredy

    2015-01-01

    Bahiagrass (Paspalum notatum Flugge) is a warm season, low-input, perennial turfgrass used for residential lawns and sides of road ways. The turf quality of bahiagrass is limited by its open growth habit, light green color, and prolific production of tall seedheads. Genetic improvement of the

  2. Covering path generation for autonomous turf-care vehicle

    DEFF Research Database (Denmark)

    Mai, Christian; Jouffroy, Jerome; Top, Søren

    2017-01-01

    A covering path generation algorithm is developed to generate a lengthwise pattern based on a polygon describing the outer boundary and obstacles (polygon holes) of a geographical area. The algorithm is applied to an autonomous lawn-care robot for application to large grass turfs, for example golf...

  3. Turf Conversion Measurement and Verification Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Stoughton, Kate M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Figueroa, Jorge [Western Resource Advocates, Boulder, CO (United States)

    2017-12-05

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings as a result of water conservation measures (WCMs) in energy performance contracts associated with converting turfgrass or other water-intensive plantings to water-wise and sustainable landscapes. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  4. The Ecology of Turf Algae on Coral Reefs

    OpenAIRE

    Harris, Jill L.

    2015-01-01

    Coral reefs are one of the most diverse and productive ecosystems on the planet. Globally, corals are declining and algae are increasing due to anthropogenic activities. While most research and conservation efforts focus on the proliferation of macroalgae, in fact most algae on coral reefs are turf algae: heterogeneous assemblages of many species of small algae. These ubiquitous and abundant algal “shag carpets” are typically overlooked or studied as a homogenous functional group. I examine c...

  5. Effect of turf on the cutting movement of female football players

    OpenAIRE

    Gerda Strutzenberger; Hue-Man Cao; Janina Koussev; Wolfgang Potthast; Gareth Irwin

    2014-01-01

    Purpose: The globalisation of artificial turf and the increase in player participation has driven the need to examine injury risk in the sport of football. The purpose of this study was to investigate the surface–player interaction in female football players between natural and artificial turf. Methods: Eight university level female football players performed an unanticipated cutting manoeuvre at an angle of 30° and 60°, on a regulation natural grass pitch (NT) and a 3G artificial turf pit...

  6. Taxonomic and Functional Metagenomic Signature of Turfs in the Abrolhos Reef System (Brazil.

    Directory of Open Access Journals (Sweden)

    Juline M Walter

    Full Text Available Turfs are widespread assemblages (consisting of microbes and algae that inhabit reef systems. They are the most abundant benthic component in the Abrolhos reef system (Brazil, representing greater than half the coverage of the entire benthic community. Their presence is associated with a reduction in three-dimensional coral reef complexity and decreases the habitats available for reef biodiversity. Despite their importance, the taxonomic and functional diversity of turfs remain unclear. We performed a metagenomics and pigments profile characterization of turfs from the Abrolhos reefs. Turf microbiome primarily encompassed Proteobacteria (mean 40.57% ± s.d. 10.36, N = 1.548,192, Cyanobacteria (mean 35.04% ± s.d. 15.5, N = 1.337,196, and Bacteroidetes (mean 11.12% ± s.d. 4.25, N = 424,185. Oxygenic and anoxygenic phototrophs, chemolithotrophs, and aerobic anoxygenic phototrophic (AANP bacteria showed a conserved functional trait of the turf microbiomes. Genes associated with oxygenic photosynthesis, AANP, sulfur cycle (S oxidation, and DMSP consumption, and nitrogen metabolism (N2 fixation, ammonia assimilation, dissimilatory nitrate and nitrite ammonification were found in the turf microbiomes. Principal component analyses of the most abundant taxa and functions showed that turf microbiomes differ from the other major Abrolhos benthic microbiomes (i.e., corals and rhodoliths and seawater. Taken together, these features suggest that turfs have a homogeneous functional core across the Abrolhos Bank, which holds diverse microbial guilds when comparing with other benthic organisms.

  7. Elite football on artificial turf versus natural grass: Movement patterns, technical standards, and player impressions

    DEFF Research Database (Denmark)

    Andersson, Helena; Ekblom, Björn; Krustrup, Peter

    2008-01-01

    The aim of the present study was to examine the movement patterns, ball skills, and the impressions of Swedish elite football players during competitive games on artificial turf and natural grass. Time - motion analyses (36 observations) and technical analyses (16 team observations) were performed....... The observed change in playing style could partly explain the male players' negative impression of artificial turf....

  8. Effect of Changes in Artificial Turf on Sports Injuries in Male University Soccer Players.

    Science.gov (United States)

    Fujitaka, Kohei; Taniguchi, Akira; Kumai, Tsukasa; Otuki, Shingo; Okubo, Mamoru; Tanaka, Yasuhito

    2017-08-01

    Studies comparing the types and severity of trauma and injuries caused by different types of field surfaces have been conducted. However, there have been no studies on sports injuries caused by temporal deterioration of long-pile artificial turf fields and related decreases in the rubber chip and silica sand infill. To investigate the influence of an artificial turf field on sports injuries in a university soccer team. Descriptive epidemiological study. A total of 397 male soccer players who were members of a single university soccer team were surveyed over a 12-year period, from April 2003 to March 2015. During this period, the team played for 4 years on a soil field (2003-2006) and 8 years on artificial turf (2007-2014). We analyzed the effect of changes in the artificial turf on the incidence rate of sports injuries (injury rate per 1000 athlete-exposures). We calculated the incidence rate of injuries sustained by the team and compared the results for each year of the study. After conversion of the field to artificial turf, there was a significant increase in the incidence of upper extremity trauma (P artificial turf (P artificial turf, there was a significant increase in the incidence of upper extremity trauma. After the refurbishing with additional rubber chips, the incidence of lower extremity muscle strain significantly declined. When analyzing measures that could prevent sports injuries related to soccer, it is necessary to take into consideration the changes that occur to the artificial turf over time.

  9. Covering path generation for autonomous turf-care vehicle

    DEFF Research Database (Denmark)

    Mai, Christian; Jouffroy, Jerome; Top, Søren

    2017-01-01

    A covering path generation algorithm is developed to generate a lengthwise pattern based on a polygon describing the outer boundary and obstacles (polygon holes) of a geographical area. The algorithm is applied to an autonomous lawn-care robot for application to large grass turfs, for example golf......-courses, which require structured and precise cutting patterns. The geographical polygon is recorded by manually driving the vehicle around the contour, resulting in a polygon given as geographical (latitude, longitude) coordinates of the vertices, which together with machine parameters are used to generate...

  10. The effects of nutrient enrichment and herbivore abundance on the ability of turf algae to overgrow coral in the Caribbean.

    Directory of Open Access Journals (Sweden)

    Mark J A Vermeij

    Full Text Available Turf algae are multispecies communities of small marine macrophytes that are becoming a dominant component of coral reef communities around the world. To assess the impact of turf algae on corals, we investigated the effects of increased nutrients (eutrophication on the interaction between the Caribbean coral Montastraea annularis and turf algae at their growth boundary. We also assessed whether herbivores are capable of reducing the abundance of turf algae at coral-algae boundaries. We found that turf algae cause visible (overgrowth and invisible negative effects (reduced fitness on neighbouring corals. Corals can overgrow neighbouring turf algae very slowly (at a rate of 0.12 mm 3 wk(-1 at ambient nutrient concentrations, but turf algae overgrew corals (at a rate of 0.34 mm 3 wk(-1 when nutrients were experimentally increased. Exclusion of herbivores had no measurable effect on the rate turf algae overgrew corals. We also used PAM fluorometry (a common approach for measuring of a colony's "fitness" to detect the effects of turf algae on the photophysiology of neighboring corals. Turf algae always reduced the effective photochemical efficiency of neighbouring corals, regardless of nutrient and/or herbivore conditions. The findings that herbivores are not capable of controlling the abundance of turf algae and that nutrient enrichment gives turf algae an overall competitive advantage over corals together have serious implications for the health of Caribbean coral reef systems. At ambient nutrient levels, traditional conservation measures aimed at reversing coral-to-algae phase shifts by reducing algal abundance (i.e., increasing herbivore populations by establishing Marine Protected Areas or tightening fishing regulations will not necessarily reduce the negative impact of turf algae on local coral communities. Because turf algae have become the most abundant benthic group on Curaçao (and likely elsewhere in the Caribbean, new conservation

  11. Catalytic converter

    Energy Technology Data Exchange (ETDEWEB)

    Liber, B.

    1991-08-22

    A catalytic converter is provided which is economical to manufacture and is not readily poisoned by contaminants in a gas stream such as would be encountered in the operation of an internal combustion engine, whereby an improved life expectancy of the unit can be achieved. The converter of the invention comprises a sintered porous body including molybdenum or a molybdenum-containing compound or a molybdenum complex. A method of forming a catlytic converter unit comprises forming a slurry including molybdenum or a molybdenum compound, forming the slurry into a sintered body member, and hardening or curing the same to form a self-sustaining body member. A method for treating an exhaust gas using the above catalytic converter is also disclosed. A preferred embodiment for an internal combustion engine is described. Examples of different catalytic compositions are included. 13 figs.

  12. Turf, team, and town: a geriatric interprofessional education program.

    Science.gov (United States)

    Macrae, Nancy

    2012-01-01

    This program provides an interprofessional course to students, allowing them to learn together with each other and their elder teachers. include refining their professional parameters (turf), learning how to successfully collaborate with other professionals (team), and determining how to effectively design intervention plans for elders within their own communities (town). Various methods of evaluation, such as journals, participation in rounds, and OSCEs, used to assess students' status are described. Both students and faculty gained clearer perceptions of other professions through their work with each other and the ability to more effectively communicate with other profession. Both also learned, through their relationships with their elder teachers, more about how their specific professions' contributions can affect elders and how elders perceive and contribute to their own communities. This program has been a successful venture. The challenge is now to devise a way to provide similar experiences to a larger group of students.

  13. Phenological observations on shrubs to predict weed emergence in turf

    Science.gov (United States)

    Masin, Roberta; Zuin, Maria Clara; Zanin, Giuseppe

    2005-09-01

    Phenology is the study of periodic biological events. If we can find easily recognizable events in common plants that precede or coincide with weed emergences, these plants could be used as indicators. Weed seedlings are usually difficult to detect in turf, so the use of phenological indicators may provide an alternative approach to predict the time when a weed appears and consequently guide management decisions. A study was undertaken to determine whether the phenological phases of some plants could serve as reliable indicators of time of weed emergence in turf. The phenology of six shrubs (Crataegus monogyna Jacq., Forsythia viridissima Lindl., Sambucus nigra L., Syringa vulgaris L., Rosa multiflora Thunb., Ziziphus jujuba Miller) and a perennial herbaceous plant [Cynodon dactylon (L.) Pers.] was observed and the emergence dynamics of four annual weed species [Digitaria sanguinalis (L.) Scop., Eleusine indica (L.) Gaertner, Setaria glauca (L.) Beauv., Setaria viridis (L.) Beauv.] were studied from 1999 to 2004 in northern Italy. A correlation between certain events and weed emergence was verified. S. vulgaris and F. viridissima appear to be the best indicators: there is a quite close correspondence between the appearance of D. sanguinalis and lilac flowering and between the beginning of emergence of E. indica and the end of lilac flowering; emergences of S. glauca and S. viridis were predicted well in relation to the end of forsythia flowering. Base temperatures and starting dates required to calculate the heat unit sums to reach and complete the flowering phase of the indicators were calculated using two different methods and the resultant cumulative growing degree days were compared.

  14. Hall et al., 2016 Artificial Turf Surrogate Surface Methods Paper Data File

    Data.gov (United States)

    U.S. Environmental Protection Agency — Mercury dry deposition data quantified via static water surrogate surface (SWSS) and artificial turf surrogate surface (ATSS) collectors. This dataset is associated...

  15. Artificial turf surfaces: perception of safety, sporting feature, satisfaction and preference of football users.

    Science.gov (United States)

    Burillo, Pablo; Gallardo, Leonor; Felipe, Jose Luis; Gallardo, Ana Maria

    2014-01-01

    The aim of this research is to understand the experience of the football sector on the use of artificial turf (satisfaction, safety, sporting feature, or the advantages and disadvantages). The study was conducted on a random selection of 627 male participants (404 amateur/semi-professional footballers, 101 coaches and 122 referees) that regularly train/compete on artificial turf in Spanish football leagues. The results of the skin abrasion, muscle strain and the possibility of sustaining an injury, on a Likert-type 10-point interval scale, gave a perception of 'somewhat dissatisfied' for the participants. The main advantages of artificial turf were their sports features, the evenness of the surface and the good state of conservation. Participants were satisfied with the artificial turf surface. Approximately three out of four participants gave an overall ranking of highly satisfied. The players were significantly less satisfied than the coaches and referees. The overall satisfaction with artificial turf fields was strongly influenced by previous experience, particularly those who had previously played on dirt pitches. These results highlight the versatility of artificial turf to adapt to any circumstance or requirement for local sport and top-level professional competitions alike.

  16. Time-dependent contact behavior between diamond and a CNT turf

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, A; Bahr, D F [School of Mechanical and Materials Engineering, Washington State University, 99164-2920 WA (United States); Fowler, S P; Jiao, J [Department of Physics, Portland State University, Portland, 97207-0751 OR (United States); Kiener, D, E-mail: anqi_qiu@wsu.edu, E-mail: dbahr@wsu.edu [Department of Materials Physics, University of Leoben, A-8700 Leoben (Austria)

    2011-07-22

    The elastic and adhesive properties of nominally vertically aligned carbon nanotube (CNT) turfs have been measured using nanoindentation. The perceived stiffness of a CNT turf is dependent on the unloading rate, which decreases at slower unloading rates. Depth-controlled nanoindentation was used to examine adhesion effects. Adhesive loads between the turf and the probe tip increased as the time the tip is in contact with the turf increased. As these effects could be from either more tubes coming into contact with the tip due to relaxation and motion of CNTs relative to one another or each tube in contact increasing its adhesive behavior and sub-contact stiffness due to tube-tube interactions within the turf, electrical resistance measurements during nanoindentation were carried out. When the tip is held at a fixed nominal depth, the current remains constant while the contact load decreases, suggesting the number of tubes in contact with the tip stays constant with time while the relaxation mechanisms in the turf occur at positions lower than the contact surface. These observations, in conjunction with in situ TEM compression test of CNT arrays, are used to describe the relative effects the various length and time scales may have on the perceived properties measured during experiments, including elastic modulus and adhesion for gecko-like dry adhesives.

  17. Time-dependent contact behavior between diamond and a CNT turf

    Science.gov (United States)

    Qiu, A.; Fowler, S. P.; Jiao, J.; Kiener, D.; Bahr, D. F.

    2011-07-01

    The elastic and adhesive properties of nominally vertically aligned carbon nanotube (CNT) turfs have been measured using nanoindentation. The perceived stiffness of a CNT turf is dependent on the unloading rate, which decreases at slower unloading rates. Depth-controlled nanoindentation was used to examine adhesion effects. Adhesive loads between the turf and the probe tip increased as the time the tip is in contact with the turf increased. As these effects could be from either more tubes coming into contact with the tip due to relaxation and motion of CNTs relative to one another or each tube in contact increasing its adhesive behavior and sub-contact stiffness due to tube-tube interactions within the turf, electrical resistance measurements during nanoindentation were carried out. When the tip is held at a fixed nominal depth, the current remains constant while the contact load decreases, suggesting the number of tubes in contact with the tip stays constant with time while the relaxation mechanisms in the turf occur at positions lower than the contact surface. These observations, in conjunction with in situ TEM compression test of CNT arrays, are used to describe the relative effects the various length and time scales may have on the perceived properties measured during experiments, including elastic modulus and adhesion for gecko-like dry adhesives.

  18. Data Converter

    NARCIS (Netherlands)

    Schinkel, Daniel; Nuijten, Petrus A.C.M.

    2005-01-01

    A data converter comprises a discrete- time sigma delta modulator e.g. for driving a Class-D power amplifier. The low-pass filter of the sigma delta modulator is modified by adding a suitably positioned pole to lower the oscillation frequency (limit cycle) of the sigma delta modulator in order to

  19. Data Converter

    NARCIS (Netherlands)

    Schinkel, Daniel

    2005-01-01

    A data converter comprises a discrete-time sigma delta modulator e.g. for driving a Class-D power amplifier. The low-pass filter of the sigma delta modulator is modified by adding a suitably positioned pole to lower the oscillation frequency (limit cycle) of the sigma delta modulator in order to

  20. Data Converter

    NARCIS (Netherlands)

    Schinkel, Daniel

    2006-01-01

    A data converter comprises a discrete-time sigma delta modulator e.g. for driving a Class-D power amplifier. The low-pass filter of the sigma delta modulator is modified by adding a suitably positioned pole to lower the oscillation frequency (limit cycle) of the sigma delta modulator in order to

  1. Wavelength Converters

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Wolfson, David

    1999-01-01

    . It is predicted that jitter accumulation can be minimised by using a 9-10 dB ratio between the signal and CW power also assuring a high extinction ratio. Using this guideline simulations show that 20 cross-gain modulation converters can be cascaded at 10 Gbit/s with only ~20 ps of accumulated jitter...... and an extinction ratio of ~10 dB.The regenerative capabilities of the cross-phase converters are described and verified experimentally at 20 Gbit/s, where the noise redistribution and improvement of the signal-to-noise ratio clearly is demonstrated by controlling the input power to an EDFA. In a similar experiment...... at 2.5 Gbit/s, the regeneration causes a reduction of the required input power to an in-line EDFA of ~6 dB for a power penalty of 1 dB at a bit error rate of 10-9. If two converters are concatenated the power requirement is reduced ~8 dB. Obviously, the power reduction allows for longer spans between...

  2. Emerging technologies advancing forage and turf grass genomics.

    Science.gov (United States)

    Kopecký, David; Studer, Bruno

    2014-01-01

    Grassland is of major importance for agricultural production and provides valuable ecosystem services. Its impact is likely to rise in changing socio-economic and climatic environments. High yielding forage grass species are major components of sustainable grassland production. Understanding the genome structure and function of grassland species provides opportunities to accelerate crop improvement and thus to mitigate the future challenges of increased feed and food demand, scarcity of natural resources such as water and nutrients, and high product qualities. In this review, we will discuss a selection of technological developments that served as main drivers to generate new insights into the structure and function of nuclear genomes. Many of these technologies were originally developed in human or animal science and are now increasingly applied in plant genomics. Our main goal is to highlight the benefits of using these technologies for forage and turf grass genome research, to discuss their potentials and limitations as well as their relevance for future applications. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. An Artificial Turf-Based Surrogate Surface Collector for the ...

    Science.gov (United States)

    This paper describes the development of a new artificial turf surrogate surface (ATSS) sampler for use in the measurement of mercury (Hg) dry deposition. In contrast to many existing surrogate surface designs, the ATSS utilizes a three-dimensional deposition surface that may more closely mimic the physical structure of many natural surfaces than traditional flat surrogate surface designs (water, filter, greased Mylar film). The ATSS has been designed to overcome several complicating factors that can impact the integrity of samples with other direct measurement approaches by providing a passive system which can be deployed for both short and extended periods of time (days to weeks), and is not contaminated by precipitation and/or invalidated by strong winds. Performance characteristics including collocated precision, in-field procedural and laboratory blanks were evaluated. The results of these performance evaluations included a mean collocated precision of 9%, low blanks (0.8 ng), high extraction efficiency (97%–103%), and a quantitative matrix spike recovery (100%). In recent years, a growing number of intensive field campaigns and routine measurement networks have provided valuable information on the rates of total mercury (Hg) wet deposition in North America (Guentzel et al., 1995; Rea et al., 1996; Dvonch et al., 1999; Landis and Keeler, 2002; Dvonch et al., 2005; Hall et al., 2005; Keeler et al., 2005; Keeler et al., 2006; Butler et al., 2008; Prestbo an

  4. Convertible barge

    Energy Technology Data Exchange (ETDEWEB)

    Howson, R.E.

    1988-08-23

    This patent describes a convertible barge, comprising: a. a deck; b. modules positioned on the deck in end to end relation and at least some of which contain pipeline processing equipment. The modules being removably attached to the deck, each module comprising a floor, ceiling, and a pair of side walls extending longitudinally of the barge between the ends; and c. means defining a closable opening comprising a roll-up door in at least one end of the modules for passing a pipeline portion from the module to a respectively adjacent module as the pipeline is being processed, for sealing the module during storage and for providing passageways between the modules and a view of pipe laying operations during use. A method for converting a barge to a lay barge, comprising: a. positioning on a deck of the barge in end to end relation of modules each of which has a floor, ceiling, and a pair of sidewalls extending longitudinally of the barge between the ends; b. providing pipeline process stations in at least some of the modules; c. removably attaching the modules to the deck; and d. providing a roll-up door in at least one of the modules ends of each module for passing a pipeline portion from the module to a respectively adjacent module as the pipeline is being processed and for providing passageways between the modules and a view of pipe laying operations during use.

  5. Football Injuries Occurring on Natural Grass and Tartan Turf. A Comparison Study Covering 17 Years at the University of Wisconsin.

    Science.gov (United States)

    Keene, J. S.; And Others

    A longitudinal study of university football players who played on Tartan Turf and/or natural grass was conducted to determine the types and severity of injuries occuring on the different field surfaces. Overall injury rates on Tartan Turf were found to be significantly lower than those sustained on natural grass. (JD)

  6. The effects of nutrient enrichment and herbivore abundance on the ability of turf algae to overgrow coral in the Caribbean

    NARCIS (Netherlands)

    Vermeij, M.J.A.; van Moorselaar, I.; Engelhard, S.; Hörnlein, C.; Vonk, S.M.; Visser, P.M.

    2010-01-01

    Turf algae are multispecies communities of small marine macrophytes that are becoming a dominant component of coral reef communities around the world. To assess the impact of turf algae on corals, we investigated the effects of increased nutrients (eutrophication) on the interaction between the

  7. A kinematic analysis of the spine during rugby scrummaging on natural and synthetic turfs.

    Science.gov (United States)

    Swaminathan, Ramesh; Williams, Jonathan M; Jones, Michael D; Theobald, Peter S

    2016-01-01

    Artificial surfaces are now an established alternative to grass (natural) surfaces in rugby union. Little is known, however, about their potential to reduce injury. This study characterises the spinal kinematics of rugby union hookers during scrummaging on third-generation synthetic (3G) and natural pitches. The spine was sectioned into five segments, with inertial sensors providing three-dimensional kinematic data sampled at 40 Hz/sensor. Twenty-two adult, male community club and university-level hookers were recruited. An equal number were analysed whilst scrummaging on natural or synthetic turf. Players scrummaging on synthetic turf demonstrated less angular velocity in the lower thoracic spine for right and left lateral bending and right rotation. The general reduction in the range of motion and velocities, extrapolated over a prolonged playing career, may mean that the synthetic turf could result in fewer degenerative injuries. It should be noted, however, that this conclusion considers only the scrummaging scenario.

  8. Turf algal epiphytes metabolically induce local pH increase, with implications for underlying coralline algae under ocean acidification

    DEFF Research Database (Denmark)

    Short, J.A.; Pedersen, Ole; Kendrick, G.A.

    2015-01-01

    The presence of epiphytic turf algae may modify the effects of ocean acidification on coralline algal calcification rates by altering seawater chemistry within the diffusive boundary layer (DBL) above coralline algal crusts. We used microelectrodes to measure the effects of turf algal epiphytes...... on seawater pH and the partial pressure of oxygen (pO2) within the DBL at the surface of Hydrolithoideae coralline algal crusts under ambient (36 Pa) CO2 and an ocean acidification scenario with elevated CO2 (200 Pa). Turf algae significantly increased the mean diel amplitude of pH and pO2, and this effect...... was more pronounced under elevated CO2. We suggest that increases in seawater CO2 under ocean acidification conditions may drive an increase in the abundance of epiphytic turf algae, consequently modifying the chemistry within the DBL. Thus, the effect of epiphytic turf algae on microscale pH is striking...

  9. Convertible Stadium

    Science.gov (United States)

    1978-01-01

    Air flotation technology used in NASA's Apollo program has found an interesting application in Hawaii's Aloha Stadium near Honolulu. The stadium's configuration can be changed, by moving entire 7,000-seat sections on a cushion of air, for best accommodation of spectators and participants at different types of events. In most stadiums, only a few hundred seats can be moved, by rolling sections on wheels or rails. At Aloha Stadium, 28,000 of the 50,000 seats can be repositioned for better spectator viewing and, additionally, for improved playing conditions. For example, a stadium designed primarily for football may compromise the baseball diamond by providing only a shallow outfield. Aloha's convertibility allows a full-size baseball field as well as optimum configurations for many other types of sports and special events. The photos show examples. The stadium owes its versatility to air flotation technology developed by General Motors. Its first large-scale application was movement of huge segments of the mammoth Saturn V moonbooster during assembly operations at Marshall Space Flight Center.

  10. Multimodal Physicochemical Characterization of Tire Crumbs Used at Synthetic Turf Fields

    Science.gov (United States)

    As part of a U.S. Federal Research Acton Plan to study possible environmental and human health implications of tire crumbs used as infill for synthetic turf, the Environmental Protection Agency (EPA) is evaluating the potential of human exposure to various chemicals from tire cru...

  11. The case of latex removal for carpet and artificial turf recycling

    NARCIS (Netherlands)

    Bottenberg, E. (Eliza); Bouwhuis, G.H. (Gerrit); Brinks, G.J. (Ger)

    2014-01-01

    For the recycling of carpet and artificial turf the latex backing is often a real stumble block. Many strategies have been developed like freezing the carpet, followed by grinding and subsequent separation of the milled particles. Once it has been separated from its backing materials, PA 6 is

  12. Comprehensive multipathway risk assessment of chemicals associated with recycled ("crumb") rubber in synthetic turf fields.

    Science.gov (United States)

    Peterson, Michael K; Lemay, Julie C; Pacheco Shubin, Sara; Prueitt, Robyn L

    2018-01-01

    Thousands of synthetic turf fields in the US are regularly used by millions of individuals (particularly children and adolescents). Although many safety assessments have concluded that there are low or negligible risks related to exposure to chemicals found in the recycled rubber used to make these fields, concerns remain about the safety of this product. Existing studies of recycled rubber's potential health risks have limitations such as small sample sizes and limited evaluation of relevant exposure pathways and scenarios. Conduct a comprehensive multipathway human health risk assessment (HHRA) of exposure to chemicals found in recycled rubber. All available North American data on the chemical composition of recycled rubber, as well as air sampling data collected on or near synthetic turf fields, were identified via a literature search. Ingestion, dermal contact, and inhalation pathways were evaluated according to US Environmental Protection Agency (US EPA) guidance, and exposure scenarios for adults, adolescents, and children were considered. Estimated non-cancer hazards and cancer risks for all the evaluated scenarios were within US EPA guidelines. In addition, cancer risk levels for users of synthetic turf field were comparable to or lower than those associated with natural soil fields. This HHRA's results add to the growing body of literature that suggests recycled rubber infill in synthetic turf poses negligible risks to human health. This comprehensive assessment provides data that allow stakeholders to make informed decisions about installing and using these fields. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Characterization of Exposure Potential during Activities on Synthetic Turf Fields with Recycled Tire Crumb Rubber Infill

    Science.gov (United States)

    The Federal Research Action Plan on Recycled Tire Crumb Used on Playing Fields and Playgrounds (FRAP), released in February 2016, is a multi-agency research plan in response to concerns over the use of tire crumb rubber as infill on synthetic turf fields. The FRAP outlines specif...

  14. Evaluation of health risks of playing sports on synthetic turf pitches with rubber granulate

    NARCIS (Netherlands)

    Oomen AG; de Groot GM; CPV; M&V

    2017-01-01

    New research by the Dutch National Institute for Public Health and the Environment (RIVM) indicates that the health risk of playing sports on synthetic turf pitches with an infill of rubber granulate is virtually negligible. Therefore, it is considered safe for people to play sports on such pitches.

  15. Differences in friction and torsional resistance in athletic shoe-turf surface interfaces.

    Science.gov (United States)

    Heidt, R S; Dormer, S G; Cawley, P W; Scranton, P E; Losse, G; Howard, M

    1996-01-01

    This study evaluated the shoe-surface interaction of 15 football shoes made by 3 manufacturers in both anterior translation and rotation using a specially designed pneumatic testing system. The shoes included traditional cleated football shoes, "court" shoes (basketball-style shoes), molded-cleat shoes, and turf shoes. Under an 11.35-kg (25-pound) axial load, all shoes were tested on synthetic turf under wet and dry conditions and on natural stadium grass. Test-retest reliability, as calculated using the Pearson Product-Moment Correlation test, was 0.85 for force of translation and 0.55 for the moment of rotation. The wet versus dry surface values on translation were significantly different for rotation about the tibial axis. Spatting, which is protective taping of the ankle and heel applied on the outside of the shoe, resulted in a reduction of forces generated in both translation and rotation. No overall difference between shoes on grass versus AstroTurf was noted. However, there were significant differences for cleated and turf shoes. Shoes tested in conditions for which they were not designed exhibited reproducible excessive or extreme minimal friction characteristics that may have safety implications. On the basis of this study, we urge shoe manufacturers to display suggested indications and playing surface conditions for which their shoes are recommended.

  16. The potential of established turf cover for cleaning oily desert soil using rhizosphere technology.

    Science.gov (United States)

    Mahmoud, H M; Suleman, P; Sorkhoh, N A; Salamah, S; Radwan, Samir S

    2011-02-01

    The rhizosphere of two turf cover sorts; Bermuda grass and American grass contained high numbers, 8.1 to 16.8 x 10(6) g(-1) of cultivable oil-utilizing and diazotrophic bacteria belonging predominantly to the genera Agrobacterium, Arthrobacter, Pseudomonas, Gordonia, and Rhodococcus. Those bacteria also grew on a nitrogen-free medium and demonstrated the ability to reduce acetylene to ethylene. These isolates grew on a wide range of n-alkanes (C9 to C40) and aromatic hydrocarbons, as sole sources of carbon. Quantitative determinations revealed that predominant bacteria consumed crude oil and representative aliphatic (n-octadecane) and aromatic (phenanthrene) hydrocarbons efficiently. The fact that those organisms had the combined activities of hydrocarbon-utilization and nitrogen-fixation makes them suitable tools for bioremediating oily desert areas that are normally poor in nitrogenous compounds. Phytoremediation experiments showed that spreading turf cover on oily desert soil inhibited oil volatilization and enhanced oil loss in soil by about 15%. Oil loss was also enhanced in turf free soil samples fertilized with NH4NO3. In conclusion, covering this oil-polluted soil with turf cover minimized atmospheric pollution, increased the numbers of the oil-utilizing/nitrogen-fixing bacteria by about 20 to 46% thus, encouraging oil attenuation.

  17. A qualitative vision of artificial turf football fields: Elite players and ...

    African Journals Online (AJOL)

    This study identified the most important parameters for the design and safety of artificial turf football fields according to professional footballers and coaches. Two semi-structured interviews were conducted. The sample consisted of 32 professional players and 25 professional coaches. The players and coaches emphasised ...

  18. Removal of nitrogen by Algal Turf Scrubber Technology in recirculating aquaculture system

    NARCIS (Netherlands)

    Valeta, J.; Verdegem, M.C.J.

    2015-01-01

    Ongoing research in recirculation aquaculture focuses on evaluating and improving the purification potential of different types of filters. Algal Turf Scrubber (ATS) are special as they combine sedimentation and biofiltration. An ATS was subjected to high nutrient loads of catfish effluent to

  19. Is genetic engineering ever going to take off in forage, turf and bioenergy crop breeding?

    Science.gov (United States)

    Wang, Zeng-Yu; Brummer, E. Charles

    2012-01-01

    Background Genetic engineering offers the opportunity to generate unique genetic variation that is either absent in the sexually compatible gene pool or has very low heritability. The generation of transgenic plants, coupled with breeding, has led to the production of widely used transgenic cultivars in several major cash crops, such as maize, soybean, cotton and canola. The process for regulatory approval of genetically engineered crops is slow and subject to extensive political interference. The situation in forage grasses and legumes is more complicated. Scope Most widely grown forage, turf and bioenergy species (e.g. tall fescue, perennial ryegrass, switchgrass, alfalfa, white clover) are highly self-incompatible and outcrossing. Compared with inbreeding species, they have a high potential to pass their genes to adjacent plants. A major biosafety concern in these species is pollen-mediated transgene flow. Because human consumption is indirect, risk assessment of transgenic forage, turf and bioenergy species has focused on their environmental or ecological impacts. Although significant progress has been made in genetic modification of these species, commercialization of transgenic cultivars is very limited because of the stringent and costly regulatory requirements. To date, the only transgenic forage crop deregulated in the US is ‘Roundup Ready’ (RR) alfalfa. The approval process for RR alfalfa was complicated, involving several rounds of regulation, deregulation and re-regulation. Nevertheless, commercialization of RR alfalfa is an important step forward in regulatory approval of a perennial outcrossing forage crop. As additional transgenic forage, turf and bioenergy crops are generated and tested, different strategies have been developed to meet regulatory requirements. Recent progress in risk assessment and deregulation of transgenic forage and turf species is summarized and discussed. PMID:22378838

  20. Autonomous Mower vs. Rotary Mower: Effects on Turf Quality and Weed Control in Tall Fescue Lawn

    Directory of Open Access Journals (Sweden)

    Michel Pirchio

    2018-02-01

    Full Text Available Autonomous mowers are battery-powered machines designed for lawn mowing that require very low human labour. Autonomous mowers can increase turf quality and reduce local noise and pollution compared with gasoline-powered rotary mowers. However, very little is known about the effects of autonomous mowing on encroaching weeds. The aim of this research was to compare the effects of an autonomous mower and an ordinary gasoline-powered mower on weed development in an artificially infested tall fescue (Festuca arundinacea Schreb. turf with different nitrogen (N rates. A three-way factor experimental design with three replications was adopted. Factor A consisted of three N rates (0, 75, and 150 kg ha−1, factor B consisted of two mowing systems (autonomous mower vs. walk-behind gasoline rotary mower equipped for mulching, and factor C which consisted of four different transplanted weed species: (a Bellis perennis L., (b Trifolium repens L.; (c Trifolium subterraneum L.; and (d Lotus corniculatus L. Of these, B. perennis is a rosette-type plant, while the other three species are creeping-type plants. The interaction between mowing system and transplanted weed species showed that the four transplanted weed species were larger when mowed by the autonomous mower than by the rotary mower. The autonomous mower yielded larger weeds probably because the constant mowing height caused the creeping weed species to grow sideways, since the turfgrass offered no competition for light. N fertilization increased turf quality and mowing quality, and also reduced spontaneous weed infestation. Autonomous mowing increased turf quality, mowing quality, but also the percentage of spontaneous weed cover.

  1. Effect of turf on the cutting movement of female football players

    Directory of Open Access Journals (Sweden)

    Gerda Strutzenberger

    2014-12-01

    Conclusion: These findings provide some support for the use of AT in female football, with no evidence to suggests that there is an increased risk of injury when performing on an artificial turf. The ankle response was less clear and further research is warranted. This initial study provides a platform for more detailed analysis, and highlights the importance of exploring the biomechanical changes in performance and injury risk with the introduction of AT.

  2. Effect of Salinity on Germination and Seedling Growth of Turf Grasses

    Directory of Open Access Journals (Sweden)

    SH Riahinia

    2012-02-01

    Full Text Available Environmental stresses, such as salinity can play an important role in disturbing different stages of plant growth, development, and especially seed germination in arid and semiarid regions in Iran. Turf grasses are highly dissipation in areas associated with saline soils and/or saline irrigation water. In order to study the effects of salinity on turf grasses germination, an experiment was conducted in factorial arrangement based on completely randomized design with three replications. Ten bulks of turf grasses were evaluated in four levels of salt treatment in Department of Agriculture in Isfahan University of Technology.These seeds included Bromus tomentolus (Semirom, Agropyron deserterom (Tabriz, Secal sp (Feraidonshahr, Stippa barbata (Mote, Agropyron sp (Semirom, Sorghum halopance (Isfahan, Agropyron elongatum (Hamedan, Bromus tomentolus-(Feraidonshahr, Hordeum morinum (Semirom, Secal sp (Pheraidan that collected from different regions of Iran. Salt treatments were, 0.5, 1, 1.5 and 2 percent of NaCl solutions (Equivalent to EC of 7.8, 15.6, 23.4 and 31.2 dS/m and H2O as control. Results showed that germination indices between bulks were significantly different (at 1% level. Increasing salinity caused a significant decrease in germination percentage and delayed mean germination time. Based on the percentage of germination and germination rate, Secale sp (Feraidonshahr and, Bromus tomentolus (Semirom, had the highest and the lowest tolerances, respectively.

  3. Advanced phenotyping offers opportunities for improved breeding of forage and turf species

    Science.gov (United States)

    Walter, Achim; Studer, Bruno; Kölliker, Roland

    2012-01-01

    Background and Aims Advanced phenotyping, i.e. the application of automated, high-throughput methods to characterize plant architecture and performance, has the potential to accelerate breeding progress but is far from being routinely used in current breeding approaches. In forage and turf improvement programmes, in particular, where breeding populations and cultivars are characterized by high genetic diversity and substantial genotype × environment interactions, precise and efficient phenotyping is essential to meet future challenges imposed by climate change, growing demand and declining resources. Scope This review highlights recent achievements in the establishment of phenotyping tools and platforms. Some of these tools have originally been established in remote sensing, some in precision agriculture, while others are laboratory-based imaging procedures. They quantify plant colour, spectral reflection, chlorophyll-fluorescence, temperature and other properties, from which traits such as biomass, architecture, photosynthetic efficiency, stomatal aperture or stress resistance can be derived. Applications of these methods in the context of forage and turf breeding are discussed. Conclusions Progress in cutting-edge molecular breeding tools is beginning to be matched by progress in automated non-destructive imaging methods. Joint application of precise phenotyping machinery and molecular tools in optimized breeding schemes will improve forage and turf breeding in the near future and will thereby contribute to amended performance of managed grassland agroecosystems. PMID:22362662

  4. Seasonal variation and occurrence of algal turf community in Lake Ladik, Turkey.

    Science.gov (United States)

    Maraşlioğlu, Faruk; Soylu, Elif Neyran; Gönülol, Arif

    2013-01-01

    The composition and seasonal variation of the algal turf of Lake Ladik were studied using samples collected from one station between June 2000 and May 2001. 50 taxa of diatoms were identified in the epiphyton. Navicula veneta, N. halophila, Nitzschia fonticola and Aulacoseira distans were particularly important on turf community. During the October month several Novicula species become progressively more important. Gomphonema lateripunctatum was particularly notable. Other diatoms were occasionally abundant, including Cymbella affinis, C. silesiaca, Navicula cryptocephala, Gomphonema olivaceum and Cyclotella ocellata. Also Navicula lanceolata and Anomoeoneis brachysira were conspicuous, owing to their large size, but were never numerically abundant. Fragilaria ulna and Nitzschia palea were found in low numbers in study area and this pointed out there has not been a remarkable abundance of algal pollution in Lake Ladik. The associations between July and August with bonds to June, January and February with bonds to April were most significant in the study period obtained by cluster analysis. Shannon diversity and evenness presented small variations during the study period. Lake Ladik presented low values of species richness particularly during summer period and highest values were recorded in April. According to canonical correspondence analysis, there was association between some Navicula and Nitzschia species with PO4-, NH3-N. Also the multivariate analysis showed, temperature as the most important factor in the distribution and abundance of diatoms on turf biomass.

  5. Agricultural runoff pollution control by a grassed swales coupled with wetland detention ponds system: a case study in Taihu Basin, China.

    Science.gov (United States)

    Zhao, Jinhui; Zhao, Yaqian; Zhao, Xiaoli; Jiang, Cheng

    2016-05-01

    The performance of a field grassed swales (GSs) coupled with wetland detention ponds (WDPs) system was monitored under four typical rainfall events to assess its effectiveness on agricultural runoff pollution control in Taihu Basin, China. The results indicated that suspended solids (SS) derived from the flush process has significant influence on pollution loads in agricultural runoff. Determination of first flush effect (FFE) indicated that total suspended solids (TSS) and total phosphorus (TP) exhibited moderate FFE, while chemical oxygen demand (COD) and total nitrogen (TN) showed weak FFE. Average removal efficiencies of 83.5 ± 4.5, 65.3 ± 6.8, 91.6 ± 3.8, and 81.3 ± 5.8 % for TSS, COD, TN, and TP were achieved, respectively. The GSs played an important role in removing TSS and TP and acted as a pre-treatment process to prevent clogging of the subsequent WDPs. Particle size distributions (PSDs) analysis indicated that coarse particles larger than 75 μm accounted for 80 % by weight of the total particles in the runoff. GSs can effectively reduce coarse particles (≥75 μm) in runoff, while its removal efficiency for fine particles (agricultural runoff pollution control.

  6. Unusual algal turfs associated with the rhodophyta Phyllophora crispa: Benthic assemblages along a depth gradient in the Central Mediterranean Sea

    Science.gov (United States)

    Bonifazi, Andrea; Ventura, Daniele; Gravina, Maria Flavia; Lasinio, Giovanna Jona; Belluscio, Andrea; Ardizzone, Gian Domenico

    2017-02-01

    Macroalgal assemblages dominated by the turf-forming alga Phyllophora crispa are described in detail for the first time in the Central Mediterranean Sea. This particular form of algal growth, which comprises an upper mixed layer of multiple algal species with a basal stratum formed by entangled thalli of P. crispa, was observed for the first time in 2012 along the promontory of Punta del Lazzaretto (Giglio Island, Italy). In this study, this assemblage was analysed to document the diversity of macroalgae and invertebrate associated communities and assess their distribution along a depth gradient. The algae forming turfs grow directly on the rock at low depth up to 10-15 m depth, while they grow above P. crispa from 15 m to 35 m depth, resulting in luxuriant beds covering up to 100% of the substrate. Multivariate analysis revealed clear differences regarding algae and invertebrate species richness and abundance between shallow and deep strata because of the dominance of Phyllophora crispa at depths greater than 20 m. The long laminal thalli of P. crispa favoured sessile fauna colonization, while the vagile species were principally linked to the architectural complexity of the turf layer created by the P. crispa, which increased the microhabitat diversity and favoured sediment deposition within the turf layer. The complex structures of these turf assemblages and their widespread distribution along the whole coast of the island suggest a well-established condition of the communities linked to the high natural sedimentation rate observed in the area.

  7. Snow mould prevalence on perennial ryegrass (Lolim perenne L. in relation to the light conditions and intensity of turf maintenance

    Directory of Open Access Journals (Sweden)

    Maria Prończuk

    2012-12-01

    Full Text Available Effect of shade, nutrition, height of mowing and density of turf on snow mould (Microdochium nivale prevalence on Lolium perenne under turf maintenance were studied in 2000-2004 at Radzików (central Poland. The materials for studies were cultivars of L. perenne originated from Poland and abroad. The turf experiments were performed in three series of trials where each factor were analysed independently. The cultivars were assessed for: density of turf, the first symptom of disease and snow mould injury in spring. The investigations revealed that shade as well as high nutrition applied in autumn and high mowing of grass influenced significantly snow mould prevalence on L. perenne. The cultivars expressed a wide range of susceptibility to snow mould. The cultivars with high density of turf were the most injured by snow mould. Disease occurred at different periods of autumn and winter, usually before snow fall. Winter weather conditions had a slight effect on changes in snow mould injury of L. perenne in subsequent years.

  8. Safety of third-generation artificial turf in male elite professional soccer players in Italian major league.

    Science.gov (United States)

    Lanzetti, R M; Ciompi, A; Lupariello, D; Guzzini, M; De Carli, A; Ferretti, A

    2017-04-01

    Our hypothesis is that there are no difference in the injury incidence on artificial turf and natural grass. During the 2011/2012 season, we recorded injuries which occurred to two Italian stadiums equipped with third-generation artificial turf during 36 games (391 players). Data were compared with the injuries which occurred in the same season in two stadiums equipped with natural grass (372 players). We recorded 43 injuries during the playing time (16.7 per 1000 h). About 23 (18.1 per 1000 h) injuries occurred on artificial turf, while 20 (15.2 per 1000 h) on the natural grass with no statistical differences P > 0.05. We recorded 10 (7.87 per 1000 h) contact and 13 (10.23 per 1000 h) non-contact injuries on artificial turf, while 5 (3.8 per 1000 h) contact and 15 (11.4 per 1000 h) non-contact injuries on natural grass P > 0.05. The overall relative risk was 1.15; 95% CI: 0.64-2.07). Our study demonstrates a substantial equivalence in injury risk on natural grass and artificial turf in elite professional soccer athletes during official matches. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers....

  10. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on air-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on air-optical wavelength converter types based on semiconductor optical amplifiers....

  11. Technologies for converter topologies

    Science.gov (United States)

    Zhou, Yan; Zhang, Haiyu

    2017-02-28

    In some embodiments of the disclosed inverter topologies, an inverter may include a full bridge LLC resonant converter, a first boost converter, and a second boost converter. In such embodiments, the first and second boost converters operate in an interleaved manner. In other disclosed embodiments, the inverter may include a half-bridge inverter circuit, a resonant circuit, a capacitor divider circuit, and a transformer.

  12. Power Converters for Accelerators

    CERN Document Server

    Visintini, R.

    2015-06-15

    Particle accelerators use a great variety of power converters for energizing their sub-systems; while the total number of power converters usually depends on the size of the accelerator or combination of accelerators (including the experimental setup), the characteristics of power converters depend on their loads and on the particle physics requirements: this paper aims to provide an overview of the magnet power converters in use in several facilities worldwide.

  13. Response of Canada geese to a turf application of diazinon AG500.

    Science.gov (United States)

    Kendall, R J; Brewer, L W; Hitchcock, R R

    1993-07-01

    We investigated the effects of a turf application of the insecticide diazinon AG500 on Canada geese (Branta canadensis) on a golf course in coastal Washington (USA). On both 19 and 26 March 1987, 1 ha of turf on a golf course located in Birch Bay, Washington was treated with diazinon AG500 at a target application rate of 2.2 kg active ingredient per hectare (AI/ha). Treated areas were then irrigated with 6 mm water. Grass and water samples were collected from three different sites one day before and 1, 3, 7 and 14 days after each application. Diazinon residues > or = 20 ppm were found in golf course grasses for one week after each application. Diazinon residues in study area ponds and creeks were > or = 17 ppb. Samples from two irrigation puddles one day post-application had 1.00 and 0.20 ppm of diazinon, respectively. Numbers of geese present declined following diazinon application; however, no goose mortality was observed. Geese spent 422 and 538 min feeding on the treated areas after the first and second diazinon applications, respectively. One goose feeding in treated areas demonstrated signs of poisoning (lethargy, ataxia) for several hours. Two other geese feeding in the treated areas may have been slightly intoxicated. During carcass searches, three American wigeon (Anas americana) carcasses were found. Based on brain cholinesterase (ChE) levels and gastrointestinal (GI) tract residues of diazinon present, we concluded that these wigeon died from diazinon poisoning. Numerous songbirds (Passeriformes) also fed on the treated turf but no apparent response to the insecticide was observed.

  14. Conservation Biological Control and Pest Performance in Lawn Turf: Does Mowing Height Matter?

    Science.gov (United States)

    Dobbs, Emily K.; Potter, Daniel A.

    2014-03-01

    With >80 million United States households engaged in lawn and gardening activities, increasing sustainability of lawn care is important. Mowing height is an easily manipulated aspect of lawn management. We tested the hypothesis that elevated mowing of tall fescue lawn grass promotes a larger, more diverse community of arthropod natural enemies which in turn provides stronger biological control services, and the corollary hypothesis that doing so also renders the turf itself less suitable for growth of insect pests. Turf-type tall fescue was mowed low (6.4 cm) or high (10.2 cm) for two growing seasons, natural enemy populations were assessed by vacuum sampling, pitfall traps, and ant baits, and predation and parasitism were evaluated with sentinel prey caterpillars, grubs, and eggs. In addition, foliage-feeding caterpillars and root-feeding scarab grubs were confined in the turf to evaluate their performance. Although some predatory groups (e.g., rove beetles and spiders) were more abundant in high-mowed grass, predation rates were uniformly high because ants, the dominant predators, were similarly abundant regardless of mowing height. Lower canopy temperatures in high-mowed grass were associated with slower growth of grass-feeding caterpillars. Higher lawn mowing reduces fuel consumption and yard waste, and promotes a deep, robust root system that reduces need for water and chemical inputs. Although in this study elevated mowing height did not measurably increase the already-high levels of predation, it did suggest additional ways through which bottom-up effects on insect pest growth might interact with natural enemies to facilitate conservation biological control.

  15. Complex and interactive effects of ocean acidification and temperature on epilithic and endolithic coral-reef turf algal assemblages

    Science.gov (United States)

    Johnson, Maggie D.; Comeau, Steeve; Lantz, Coulson A.; Smith, Jennifer E.

    2017-12-01

    Turf algal assemblages are ubiquitous primary producers on coral reefs, but little is known about the response of this diverse group to ocean acidification (OA) across different temperatures. We tested the hypothesis that CO2 influences the functional response of epilithic and endolithic turf assemblages to increasing temperature. Replicate carbonate plugs covered by turf were collected from the reef and exposed to ambient and high pCO2 (1000 µatm) conditions for 3 weeks. Each pCO2 treatment was replicated across six temperatures (24.0-31.5 °C) that spanned the full seasonal temperature range on a fringing reef in Moorea, French Polynesia, and included one warming treatment (3 °C above daily average temperatures). Temperature and CO2 enrichment had complex, and sometimes interactive, effects on turf metabolism and growth. Photosynthetic and respiration rates were enhanced by increasing temperature, with an interactive effect of CO2 enrichment. Photosynthetic rates were amplified by high CO2 in the warmest temperatures, while the increase in respiration rates with temperature were enhanced under ambient CO2. Epilithic turf growth rates were not affected by temperature, but increased in response to CO2 enrichment. We found that CO2 and temperature interactively affected the endolithic assemblage, with the highest growth rates under CO2 enrichment, but only at the warmest temperatures. These results demonstrate how OA may influence algal physiology and growth across a range of ecologically relevant temperatures, and indicate that the effects of CO2 enrichment on coral-reef turf assemblages can be temperature dependent. The complex effects of CO2 enrichment and temperature across a suite of algal responses illustrates the importance of incorporating multiple stressors into global change experiments.

  16. Physical and Physiological Responses of Amateur Football Players on Third-Generation Artificial Turf Systems During Simulated Game Situations.

    Science.gov (United States)

    Sánchez-Sánchez, Javier; García-Unanue, Jorge; Felipe, José L; Jiménez-Reyes, Pedro; Viejo-Romero, David; Gómez-López, Maite; Hernando, Enrique; Burillo, Pablo; Gallardo, Leonor

    2016-11-01

    Sánchez-Sánchez, J, García-Unanue, J, Felipe, JL, Jiménez-Reyes, P, Viejo-Romero, D, Gómez-López, M, Hernando, E, Burillo, P, and Gallardo, L. Physical and physiological responses of amateur football players on third generation artificial turf systems during simulated game situations. J Strength Cond Res 30(11): 3165-3177, 2016-The aim of this study is to evaluate the physical and physiological load imposed on amateur football players in a simulated game situation on different artificial turf systems. For that purpose, 20 football players (21.65 ± 3.10 year old) were monitored with Global Positioning Systems and heart rate bands during 45-minutes games on 4 selected artificial turf systems. The results show more covered distance in high-intensity ranges on the system with lower levels of damping and higher rates of rotational traction (p ≤ 0.05). Likewise, this system of artificial turf demonstrated a high number of sprints (12.65 ± 5.67) and more elevated maximum speed peaks during the last part of the game (28.16 ± 2.90 km·h) in contrast to the systems with better damping capacity (p ≤ 0.05). On the other hand, the physiological load was similar across the 4 artificial turf systems (p > 0.05). Finally, the regression analysis demonstrated a significant influence of the mechanical properties of the surface on global distance (15.4%), number (12.6%), and maximum speed (16.6%) of the sprints. To conclude, the mechanical variability of the artificial turf systems resulted in differences in the activity profiles and the players' perceptions during simulated football games.

  17. Dynamics of the nitrogen content in aboveground phytomass on the turf after fertilization of different forms of fertilizers

    OpenAIRE

    HRIC, Peter; Ján JANČOVIČ; KOVÁR, Peter; Ľuboš VOZÁR

    2017-01-01

    The aim of this experiment was to find out dynamics of the nitrogen (N) content in aboveground phytomass on the turf after fertilization of different forms of fertilizers under non–irrigated conditions. The experiment was carried out in warm and dry conditions in the area of Nitra (Slovak Republic). There were included 7 treatments: 1. Without fertilization, 2. Saltpetre with dolomite, Superphosphate, Potassium salt, 3. Turf fertilizer 15–3–8 (+ 3MgO + 0.8Fe + 18S), 4. Slow release fertilizer...

  18. The Effect of Varying Speed Release of Nutrients from Fertilizers on Growth-production Process of Turf

    OpenAIRE

    Peter Hric; Ján Jančovič; Peter Kovár; Ľuboš Vozár

    2016-01-01

    The aim of this experiment was to compare the influence of fertilizers with different speed of nutrients release on growth–production indicators of turf under non–irrigated conditions. The experiment was carried in warm and dry conditions in area Nitra (Slovak Republic). In the experiment were followed 5 treatments (1. without fertilization, 2. Nitre with dolomite, Superphosphate, Potassium salt, 3. Turf fertilizer Travcerit®, 4. Slow release fertilizer SRF NPK 14–5–14 (+ 4CaO + 4MgO + 7S), 5...

  19. Turf algae-mediated coral damage in coastal reefs of Belize, Central America

    KAUST Repository

    Wild, Christian

    2014-09-16

    Many coral reefs in the Caribbean experienced substantial changes in their benthic community composition during the last decades. This often resulted in phase shifts from scleractinian coral dominance to that by other benthic invertebrate or algae. However, knowledge about how the related role of coral-algae contacts may negatively affect corals is scarce. Therefore, benthic community composition, abundance of algae grazers, and the abundance and character of coral-algae contacts were assessed in situ at 13 Belizean reef sites distributed along a distance gradient to the Belizean mainland (12–70 km): Mesoamerican Barrier Reef (inshore), Turneffe Atoll (inner and outer midshore), and Lighthouse Reef (offshore). In situ surveys revealed significantly higher benthic cover by scleractinian corals at the remote Lighthouse Reef (26–29%) when compared to the other sites (4–19%). The abundance of herbivorous fish and the sea urchin Diadema antillarum significantly increased towards the offshore reef sites, while the occurrence of direct coral-algae contacts consequently increased significantly with decreasing distance to shore. About 60% of these algae contacts were harmful (exhibiting coral tissue damage, pigmentation change, or overgrowth) for corals (mainly genera Orbicella and Agaricia), particularly when filamentous turf algae were involved. These findings provide support to the hypothesis that (turf) algae-mediated coral damage occurs in Belizean coastal, near-shore coral reefs.

  20. Turf algae-mediated coral damage in coastal reefs of Belize, Central America

    Directory of Open Access Journals (Sweden)

    Christian Wild

    2014-09-01

    Full Text Available Many coral reefs in the Caribbean experienced substantial changes in their benthic community composition during the last decades. This often resulted in phase shifts from scleractinian coral dominance to that by other benthic invertebrate or algae. However, knowledge about how the related role of coral-algae contacts may negatively affect corals is scarce. Therefore, benthic community composition, abundance of algae grazers, and the abundance and character of coral-algae contacts were assessed in situ at 13 Belizean reef sites distributed along a distance gradient to the Belizean mainland (12–70 km: Mesoamerican Barrier Reef (inshore, Turneffe Atoll (inner and outer midshore, and Lighthouse Reef (offshore. In situ surveys revealed significantly higher benthic cover by scleractinian corals at the remote Lighthouse Reef (26–29% when compared to the other sites (4–19%. The abundance of herbivorous fish and the sea urchin Diadema antillarum significantly increased towards the offshore reef sites, while the occurrence of direct coral-algae contacts consequently increased significantly with decreasing distance to shore. About 60% of these algae contacts were harmful (exhibiting coral tissue damage, pigmentation change, or overgrowth for corals (mainly genera Orbicella and Agaricia, particularly when filamentous turf algae were involved. These findings provide support to the hypothesis that (turf algae-mediated coral damage occurs in Belizean coastal, near-shore coral reefs.

  1. Turf algae-mediated coral damage in coastal reefs of Belize, Central America.

    Science.gov (United States)

    Wild, Christian; Jantzen, Carin; Kremb, Stephan Georg

    2014-01-01

    Many coral reefs in the Caribbean experienced substantial changes in their benthic community composition during the last decades. This often resulted in phase shifts from scleractinian coral dominance to that by other benthic invertebrate or algae. However, knowledge about how the related role of coral-algae contacts may negatively affect corals is scarce. Therefore, benthic community composition, abundance of algae grazers, and the abundance and character of coral-algae contacts were assessed in situ at 13 Belizean reef sites distributed along a distance gradient to the Belizean mainland (12-70 km): Mesoamerican Barrier Reef (inshore), Turneffe Atoll (inner and outer midshore), and Lighthouse Reef (offshore). In situ surveys revealed significantly higher benthic cover by scleractinian corals at the remote Lighthouse Reef (26-29%) when compared to the other sites (4-19%). The abundance of herbivorous fish and the sea urchin Diadema antillarum significantly increased towards the offshore reef sites, while the occurrence of direct coral-algae contacts consequently increased significantly with decreasing distance to shore. About 60% of these algae contacts were harmful (exhibiting coral tissue damage, pigmentation change, or overgrowth) for corals (mainly genera Orbicella and Agaricia), particularly when filamentous turf algae were involved. These findings provide support to the hypothesis that (turf) algae-mediated coral damage occurs in Belizean coastal, near-shore coral reefs.

  2. An optimal management of water for a turf irrigation system in Milan area (Italy)

    Science.gov (United States)

    Deangelis, Maria Laura; Mazzoleni, Abramo

    2015-04-01

    The design of an irrigation system is not just "draw", but a complex organization that takes into account of a whole range of information that are inherently contained in the graphic representation of the final plan. The various stages that make up the activity of designing an irrigation system include: general survey of the site to be irrigated, meteorological analysis of the site and the calculation of the water requirement, development of the project with the choice and location of the components. The use of a numerical model based on water balance in a soil-water-atmosphere system allows the evaluation of the optimal water requirement as a function of meteorological characteristics. The water saving is enabled through a smart programming of a modern automation system for irrigation. The meteorological data analysis was conducted choosing from the series of two special years: the year 2002, particularly rainy, and the other in 2007, extraordinarily drought. The determination of the water requirements of turf was conducted on a daily scale. The water consumption was calculated in a classic irrigation system that covers the delivery of 5 mm of water per day, interrupted only by a rain sensor. In the second case water consumption was analysed by managing an irrigation controller based on actual water needs of turf day by day. For the two years in question water savings ranges between 13 and 27%.

  3. Morphological and community changes of turf algae in competition with corals

    Science.gov (United States)

    Cetz-Navarro, Neidy P.; Quan-Young, Lizette I.; Espinoza-Avalos, Julio

    2015-08-01

    The morphological plasticity and community responses of algae competing with corals have not been assessed. We evaluated eight morphological characters of four species of stoloniferous clonal filamentous turf algae (FTA), including Lophosiphonia cristata (Lc) and Polysiphonia scopulorum var. villum (Psv), and the composition and number of turf algae (TA) in competition for space with the coral Orbicella spp. under experimental and non-manipulated conditions. All FTA exhibited morphological responses, such as increasing the formation of new ramets (except for Psv when competing with O. faveolata). Opposite responses in the space between erect axes were found when Psv competed with O. faveolata and when Lc competed with O. annularis. The characters modified by each FTA species, and the number and composition of TA species growing next to coral tissue differed from that of the TA growing at ≥3 cm. The specific and community responses indicate that some species of TA can actively colonise coral tissue and that fundamental competitive interactions between the two types of organisms occur within the first millimetres of the coral-algal boundary. These findings suggest that the morphological plasticity, high number, and functional redundancy of stoloniferous TA species favour their colonisation of coral tissue and resistance against coral invasion.

  4. Power converters definitions, classification and converter topologies

    CERN Document Server

    Bordry, Frederick

    2006-01-01

    This paper introduces power conversion principles and defines the terminology. The concepts of sources and switches are defined and classified. From the basic laws of source interconnections, a generic method of power converter synthesis is presented. Some examples illustrate this systematic method. Finally, the notions of commutation cell and soft commutation are introduced and discussed.

  5. Restoring species-rich meadow by means of turf transplantation: long-term colonization of ex-arable land

    Czech Academy of Sciences Publication Activity Database

    Mudrák, Ondřej; Fajmon, K.; Jongepierová, I.; Doležal, Jiří

    2017-01-01

    Roč. 20, č. 1 (2017), s. 62-73 ISSN 1402-2001 R&D Projects: GA ČR GA13-13368S Institutional support: RVO:67985939 Keywords : Turf transfer * Grassland restoration * Spontaneous colonization Subject RIV: EH - Ecology, Behaviour OBOR OECD: Ecology Impact factor: 2.474, year: 2016

  6. Tribological behaviour of skin equivalents and ex-vivo human skin against the material components of artificial turf in sliding

    NARCIS (Netherlands)

    Morales Hurtado, Marina; Peppelman, P.; Zeng, Xiangqiong; van Erp, P.E.J.; van der Heide, Emile

    2016-01-01

    This research aims to analyse the interaction of three artificial skin equivalents and human skin against the main material components of artificial turf. The tribological performance of Lorica, Silicone Skin L7350 and a recently developed Epidermal Skin Equivalent (ESE) were studied and compared to

  7. An Artificial Turf-Based Surrogate Surface Collector for the Direct Measurement of Atmospheric Mercury Dry Deposition

    Science.gov (United States)

    This paper describes the development of a new artificial turf surrogate surface (ATSS) sampler for use in the measurement of mercury (Hg) dry deposition. In contrast to many existing surrogate surface designs, the ATSS utilizes a three-dimensional deposition surface that may more...

  8. High speed data converters

    CERN Document Server

    Ali, Ahmed MA

    2016-01-01

    This book covers high speed data converters from the perspective of a leading high speed ADC designer and architect, with a strong emphasis on high speed Nyquist A/D converters. For our purposes, the term 'high speed' is defined as sampling rates that are greater than 10 MS/s.

  9. Electrical Power Converter

    NARCIS (Netherlands)

    Ferreira, J.A.

    2014-01-01

    Electrical power converter for converting electrical power of a power source connected or connectable at an input to electrical DC-power at an output, wherein between the input and the output a first circuit of submodules is provided, wherein said first circuit of submodules and the power source

  10. Digital to Analog Converter

    NARCIS (Netherlands)

    Westra, Jan R.; Annema, Anne J.; van den Boom, Jeroen M.; Dijkmans, Eise C.

    2001-01-01

    A digital to analog converter (DAC) for converting a digital signal (DS) having a maximum voltage range which corresponds to a first supply voltage (UL) into an analog signal (UOUT) having a maximum voltage range which corresponds to a second supply voltage (UH). The first supply voltage (UL) is

  11. Digital to Analog Converter

    NARCIS (Netherlands)

    Westra, Jan R.; Annema, Anne J.; van den Boom, Jeroen M.; Dijkmans, Eise C.

    2006-01-01

    A digital to analog converter (DAC) for converting a digital signal (DS) having a maximum voltage range which corresponds to a first supply voltage (UL) into an analog signal (UOUT) having a maximum voltage range which corresponds to a second supply voltage (UH). The first supply voltage (UL) is

  12. Turf Toe

    Science.gov (United States)

    ... a 5-digit zip code. Please enter a city or last name. Search Where do you hurt? Interactive Foot Diagram Sesamoid Injuries in the Foot What Is a Sesamoid? A sesamoid is a bone embedded in a tendon. Sesamoids are found in ...

  13. Comparison of the incidence, nature and cause of injuries sustained on dirt field and artificial turf field by amateur football players

    Directory of Open Access Journals (Sweden)

    Kordi Ramin

    2011-02-01

    Full Text Available Abstract Background Data on the incidence, nature, severity and cause of match football injuries sustained on dirt field are scarce. The objectives of this study was to compare the incidence, nature, severity and cause of match injuries sustained on dirt field and artificial turf field by amateur male football players. Methods A prospective two-cohort design was employed. Participants were 252 male football players (mean age 27 years, range 18-43 in 14 teams who participated in a local championship carried on a dirt field and 216 male football players (mean age 28 years, range 17-40 in 12 teams who participated in a local championship carried on a artificial turf field in the same zone of the city. Injury definitions and recording procedures were compliant with the international consensus statement for epidemiological studies of injuries in football. Results The overall incidence of match injuries for men was 36.9 injuries/1000 player hours on dirt field and 19.5 on artificial turf (incidence rate ratio 1.88; 95% CI 1.19-3.05. Most common injured part on dirt field was ankle (26.7% and on artificial turf was knee (24.3%. The most common injury type in the dirt field was skin injuries (abrasion and laceration and in the artificial turf was sprain and ligament injury followed by haematoma/contusion/bruise. Most injuries were acute (artificial turf 89%, dirt field 91% and resulted from player-to-player contact (artificial turf 59.2%, dirt field 51.4%. Most injuries were slight and minimal in dirt field cohort but in artificial turf cohort the most injuries were mild. Conclusions There were differences in the incidence and type of football match injuries sustained on dirt field and artificial turf.

  14. Dynamics of the nitrogen content in aboveground phytomass on the turf after fertilization of different forms of fertilizers

    Directory of Open Access Journals (Sweden)

    Peter HRIC

    2017-06-01

    Full Text Available The aim of this experiment was to find out dynamics of the nitrogen (N content in aboveground phytomass on the turf after fertilization of different forms of fertilizers under non–irrigated conditions. The experiment was carried out in warm and dry conditions in the area of Nitra (Slovak Republic. There were included 7 treatments: 1. Without fertilization, 2. Saltpetre with dolomite, Superphosphate, Potassium salt, 3. Turf fertilizer 15–3–8 (+ 3MgO + 0.8Fe + 18S, 4. Slow release fertilizer SRF NPK 14–5–14 (+ 4CaO + 4MgO + 7S, 5. Controlled release fertilizer Duslocote NPK (S 13-9-18 (+ 6S, 6. Organic fertilizer Condit (5-1-1 and 7. Organic fertilizer Veget (3-2-1. In the begging of the seasons fertilizing by controlled release fertilizer Duslocote NPK (S 13-9-18 (+ 6S had a slow onset of action. The opposite trend had use of organic fertilizer Condit (5-1-1 on nitrogen content in aboveground turf phytomass. The nitrogen concentration was statistically higher in variants fertilized with inorganic fertilizer and organic fertilizer Condit (5-1-1 (33,727 mg*kg-1 – 36,737 mg*kg-1 as a non-fertilized turf (28,446 mg*kg-1. Higher nitrogen content in aboveground phytomass was after application of organic fertilizer Condit (5-1-1 into the turf in comparison with fertilization inorganic fertilizers.

  15. Re-aerosolization of Bacillus thuringiensis spores from concrete and turf.

    Science.gov (United States)

    Bishop, A H; O'Sullivan, C M; Lane, A; Butler Ellis, M C; Sellors, W J

    2017-05-01

    Spores of Bacillus anthracis deposited on surfaces can become airborne again as a result of air currents and mechanical forces. As such, they are a potential source of infection by inhalation. Spores of Bacillus thuringiensis were used to quantify this phenomenon in a simulation of outdoor conditions. Concrete and turf surfaces were inoculated by aerosol to produce high spore densities (greater than 1 × 10 9  CFU per m 2 ) which were then subjected to the passage of air at 10 ms -1 with and without simulated walking. Re-aerosolized spores were sampled by wetted wall cyclone air samplers. The mean total re-aerosolization rate from concrete (m -2  min -1 ) was 1·16 × 10 -3 for wind alone and 3·2 × 10 -3 for wind and simulated walking while for turf the respective values were 2·7 × 10 -4 and 6·7 × 10 -4 . Following the malicious and/or accidental release of an aerosol of Bacillus anthracis spores, the immediate risk of human inhalation would decrease as the spores were deposited on surfaces or diluted by wind flow. There is, however, a concern that the deposited spores could become re-aerosolized and so present an ongoing hazard. Using an accurate simulant for B. anthracis spores a method is reported here that allowed the enumeration of re-aerosolized spores from concrete and turf by wind flow and footfall. Under the conditions used, the rates of re-aerosolization were low. These findings will need to be verified under real outdoor conditions before the true significance in terms of secondary exposure to pathogenic spores can be assessed. © 2017 Crown copyright. Letter of Applied Microbiology © 2017 The Society for Applied Microbiology. This article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland.

  16. Human health risk assessment of synthetic turf fields based upon investigation of five fields in Connecticut.

    Science.gov (United States)

    Ginsberg, Gary; Toal, Brian; Simcox, Nancy; Bracker, Anne; Golembiewski, Brian; Kurland, Tara; Hedman, Curtis

    2011-01-01

    Questions have been raised regarding possible exposures when playing sports on synthetic turf fields cushioned with crumb rubber. Rubber is a complex mixture with some components possessing toxic and carcinogenic properties. Exposure is possible via inhalation, given that chemicals emitted from rubber might end up in the breathing zone of players and these players have high ventilation rates. Previous studies provide useful data but are limited with respect to the variety of fields and scenarios evaluated. The State of Connecticut investigated emissions associated with four outdoor and one indoor synthetic turf field under summer conditions. On-field and background locations were sampled using a variety of stationary and personal samplers. More than 20 chemicals of potential concern (COPC) were found to be above background and possibly field-related on both indoor and outdoor fields. These COPC were entered into separate risk assessments (1) for outdoor and indoor fields and (2) for children and adults. Exposure concentrations were prorated for time spent away from the fields and inhalation rates were adjusted for play activity and for children's greater ventilation than adults. Cancer and noncancer risk levels were at or below de minimis levels of concern. The scenario with the highest exposure was children playing on the indoor field. The acute hazard index (HI) for this scenario approached unity, suggesting a potential concern, although there was great uncertainty with this estimate. The main contributor was benzothiazole, a rubber-related semivolatile organic chemical (SVOC) that was 14-fold higher indoors than outdoors. Based upon these findings, outdoor and indoor synthetic turf fields are not associated with elevated adverse health risks. However, it would be prudent for building operators to provide adequate ventilation to prevent a buildup of rubber-related volatile organic chemicals (VOC) and SVOC at indoor fields. The current results are generally

  17. Effects of temperature and photoperiod on postponing bermudagrass (Cynodon dactylon [L.] Pers.) turf dormancy.

    Science.gov (United States)

    Esmaili, Somayeh; Salehi, Hassan

    2012-06-15

    Growth chamber and field experiments were carried out to determine the effects of extended photoperiod under low and freezing temperatures on bermudagrass turf dormancy at Bajgah, in the southern part of Iran. The experiment in the growth chamber was conducted with four temperature regimes (15, 7.5, 0 and -7.5°C) and three light durations (8, 12 and 16h) in a completely randomized design with four replications. The field study was conducted in two consecutive years (2008-2009) with three light durations (8, 12 and 16h) in months with natural short day length and arranged in a randomized complete blocks design with three replications. Results in both experiments showed that decreasing temperature and photoperiod decreased verdure fresh and dry weight, shoot height, tiller density, leaf area and chlorophyll and relative water contents (RWC). However, rooting depth and fresh weight of roots increased in the growth chamber. Decreasing the temperature and light duration increased electrolyte leakage and proline content. Reducing sugars increased with decreasing temperature and declined with lowering light duration in both shoots and roots. Starch content of both shoots and roots showed an adverse trend compared to reducing sugars; starch content increased in both shoots and roots in all treatments by shortening the photoperiod. Practically, the problem of bermudagrass turf's dormancy could be solved via increasing the photoperiod in months with short day lengths. This treatment would be efficient and useful for turfgrass managers to apply in landscapes and stadiums. Copyright © 2012 Elsevier GmbH. All rights reserved.

  18. Microminiature thermionic converters

    Science.gov (United States)

    King, Donald B.; Sadwick, Laurence P.; Wernsman, Bernard R.

    2001-09-25

    Microminiature thermionic converts (MTCs) having high energy-conversion efficiencies and variable operating temperatures. Methods of manufacturing those converters using semiconductor integrated circuit fabrication and micromachine manufacturing techniques are also disclosed. The MTCs of the invention incorporate cathode to anode spacing of about 1 micron or less and use cathode and anode materials having work functions ranging from about 1 eV to about 3 eV. Existing prior art thermionic converter technology has energy conversion efficiencies ranging from 5-15%. The MTCs of the present invention have maximum efficiencies of just under 30%, and thousands of the devices can be fabricated at modest costs.

  19. Improving Power Converter Reliability

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental...

  20. Microsatellite CONVERT Input File

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Microsatellite data formatted for the software CONVERT, which includes dataset numerical IDs, sampling site names, and locus identifiers. Rows 291-294 provides...

  1. Advanced converter technology

    Science.gov (United States)

    Banic, C. V.; Eckhouse, S. A.; Kornbrust, F. J.; Lifman, K.; Peterson, J. L.; Rosati, R. W.; Young, D.

    An advanced converter system for use in electrochemical energy storge was defined. Improved and experimental apparatus are designed to measure these characteristics and to enable better definition of the battery power conditioner interface. Improvement of energy storage system performance through modification of battery converter characteristics is investigated. Power conditioning based on fuel cell use was evaluated. It is concluded that this high switching frequency concept has the potential for significantly reducing the size and cost of battery plant power conditioners.

  2. Comparison of the incidence, nature and cause of injuries sustained on grass and new generation artificial turf by male and female football players. Part 2: training injuries.

    Science.gov (United States)

    Fuller, Colin W; Dick, Randall W; Corlette, Jill; Schmalz, Rosemary

    2007-08-01

    To compare the incidence, nature, severity and cause of training injuries sustained on new generation artificial turf and grass by male and female footballers. The National Collegiate Athletic Association Injury Surveillance System was used for a two-season (August to December) prospective study involving American college and university football teams (2005 season: men 52 teams, women 64 teams; 2006 season: men 54 teams, women 72 teams). Injury definitions and recording procedures were compliant with the international consensus statement for epidemiological studies of injuries in football. Athletic trainers recorded details of the playing surface and the location, diagnosis, severity and cause of all training injuries. The number of days lost from training and match play was used to define the severity of an injury. Training exposures (player hours) were recorded on a team basis. The overall incidence of training injuries for men was 3.34 injuries/1000 player hours on artificial turf and 3.01 on grass (incidence ratio 1.11; p = 0.21) and for women it was 2.60 injuries/1000 player hours on artificial turf and 2.79 on grass (incidence ratio 0.93; p = 0.46). For men, the mean severity of injuries that were not season ending injuries was 9.4 days (median 5) on artificial turf and 7.8 days (median 4) on grass and, for women, 10.5 days (median 4) on artificial turf and 10.0 days (median 5) on grass. Joint (non-bone)/ligament/cartilage and muscle/tendon injuries to the lower limbs were the most common general categories of injury on artificial turf and grass for both male and female players. Most training injuries were acute (men: artificial turf 2.92, grass 2.63, p = 0.24; women: artificial turf 1.94, grass 2.23, p = 0.21) and resulted from player-to-player contact (men: artificial turf 1.08, grass 0.85, p = 0.10; women: artificial turf 0.47, grass 0.56; p = 0.45). There were no major differences between the incidence, severity, nature or cause of training injuries

  3. Comparison of the incidence, nature and cause of injuries sustained on grass and new generation artificial turf by male and female football players. Part 1: match injuries.

    Science.gov (United States)

    Fuller, Colin W; Dick, Randall W; Corlette, Jill; Schmalz, Rosemary

    2007-08-01

    To compare the incidence, nature, severity and cause of match injuries sustained on grass and new generation artificial turf by male and female footballers. The National Collegiate Athletic Association Injury Surveillance System was used for a two-season (August to December) prospective study of American college and university football teams (2005 season: men 52 teams, women 64 teams; 2006 season: men 54 teams, women 72 teams). Injury definitions and recording procedures were compliant with the international consensus statement for epidemiological studies of injuries in football. Athletic trainers recorded details of the playing surface and the location, diagnosis, severity and cause of all match injuries. The number of days lost from training and match play was used to define the severity of an injury. Match exposures (player hours) were recorded on a team basis. The overall incidence of match injuries for men was 25.43 injuries/1000 player hours on artificial turf and 23.92 on grass (incidence ratio 1.06; p = 0.46) and for women was 19.15 injuries/1000 player hours on artificial turf and 21.79 on grass (incidence ratio = 0.88; p = 0.16). For men, the mean severity of non-season ending injuries was 7.1 days (median 5) on artificial turf and 8.4 days (median 5) on grass and, for women, 11.2 days (median 5) on artificial turf and 8.9 days (median 5) on grass. Joint (non-bone)/ligament/cartilage and contusion injuries to the lower limbs were the most common general categories of match injury on artificial turf and grass for both male and female players. Most injuries were acute (men: artificial turf 24.60, grass 22.91; p = 0.40; women: artificial turf 18.29, grass 20.64; p = 0.21) and resulted from player-to-player contact (men: artificial turf 14.73, grass 13.34; p = 0.37; women: artificial turf 10.72; grass 11.68; p = 0.50). There were no major differences in the incidence, severity, nature or cause of match injuries sustained on new generation artificial turf and

  4. Grazing Effects of Fish versus Sea Urchins on Turf Algae and Coral Recruits: Possible Implications for Coral Reef Resilience and Restoration

    OpenAIRE

    Leor Korzen; Alvaro Israel; Avigdor Abelson

    2011-01-01

    Herbivory is an important structuring factor in coral reefs, influencing seaweed abundance, competitive interactions between seaweeds and corals, and coral reef resilience. Despite reports of a drastic increase in the cover of benthic algae and turf dominancy in the coral reefs of Eilat, Red Sea, very little is known about the factors responsible for this phenomenon or the possible effects of herbivory on turf algae and coral recruits. Here, we examine the effects of herbivory by experimental...

  5. Incidence, Mechanisms, and Severity of Match-Related Collegiate Men's Soccer Injuries on FieldTurf and Natural Grass Surfaces: A 6-Year Prospective Study.

    Science.gov (United States)

    Meyers, Michael C

    2017-03-01

    Numerous injuries have been attributed to playing on artificial turf. More recently, newer generations of artificial turf have been developed to duplicate the playing characteristics of natural grass. Although artificial turf has been deemed safer than natural grass in some studies, few long-term studies have been conducted comparing match-related collegiate soccer injuries between the 2 playing surfaces. Collegiate male soccer athletes do not experience any difference in the incidence, mechanisms, or severity of match-related injuries between FieldTurf and natural grass. Cohort study; Level of evidence, 2. Male soccer athletes from 11 universities were evaluated over 6 seasons. Demographic features and predictors included player position, cleat design, player weight, turf age, and environmental factors. Outcomes of interest included injury incidence, injury category, time loss, injury mechanism and situation, type of injury, injury grade and anatomic location, injury severity, head and lower extremity trauma, and elective medical procedures. All match-related injuries were evaluated by the attending head athletic trainer and team physicians on site and subsequently in the physician's office when further follow-up and treatment were deemed necessary. In sum, 765 collegiate games were evaluated for match-related soccer injuries sustained on FieldTurf or natural grass during 6 seasons. Overall, 380 team games (49.7%) were played on FieldTurf versus 385 team games (50.3%) played on natural grass. A total of 722 injuries were documented, with 268 (37.1%) occurring on FieldTurf and 454 (62.9%) on natural grass. Multivariate analysis per 10 team games indicated a significant playing surface effect: F2,720 = 7.260, P = .001. A significantly lower total injury incidence rate (IIR) of 7.1 (95% CI, 6.6-7.5) versus 11.8 (95% CI, 11.3-12.2; P soccer. The findings of this study, however, may not be generalizable to other levels of competition or to other artificial surfaces.

  6. Torsional injuries of the lower limb: an analysis of the frictional torque between different types of football turf and the shoe outsole.

    Science.gov (United States)

    Smeets, Kristof; Jacobs, Pieter; Hertogs, Robbin; Luyckx, Jean-Philippe; Innocenti, Bernardo; Corten, Kristoff; Ekstrand, Jan; Bellemans, Johan

    2012-12-01

    Football turf is increasingly used in European soccer competition. Little is known on the rotational torque that players experience on these fields. High rotational torques between the shoe outsole and the sports surface has been correlated with torsional injuries of the lower limb and knee. To evaluate the effect of six parameters that could influence the rotational torque between the shoe outsole and the latest generation football turf. Controlled laboratory study. A testing apparatus was constructed to measure the peak torque generated during a controlled rotation of the foot. Six parameters that could potentially influence the frictional forces, were considered: (1) the sports surface, (2) the shoe outsole cleat design, (3) the weather conditions, (4) the weight, (5) the presence of an impact and (6) the direction of rotation. The football turf without infill showed significantly lower frictional torques than natural grass whereas a football turf with sand/rubber infill had significantly higher torques. Blades were associated with significantly higher torques than studs on natural grass and on one football turf with sand/rubber infill. Dry weather was associated with higher torques only for the football turf without infill. The torque increased linearly and significantly with an increasing vertical load. The rotational torque increased significantly following an impact. Torques on external rotational movements were significantly higher with blades. Important differences in rotational torques are found and could be seen as potential risk factors for torsional injuries of the lower limb.

  7. SSG Wave Energy Converter

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Vicinanza, Diego; Frigaard, Peter

    2008-01-01

    The SSG (Sea Slot-cone Generator) is a wave energy converter of the overtopping type. The structure consists of a number of reservoirs one on the top of each others above the mean water level, in which the water of incoming waves is stored temporary. In each reservoir, expressively designed low...... head hydroturbines are converting the potential energy of the stored water into power. A key to success for the SSG will be the low cost of the structure and its robustness. The construction of the pilot plant is scheduled and this paper aims to describe the concept of the SSG wave energy converter...... and the studies behind the process that leads to its construction. The pilot plant is an on-shore full scale module in 3 levels with an expected power production of 320 MWh/y in the North Sea. Location, wave climate and laboratory tests results will be used here to describe the pilot plant and its characteristics....

  8. Effects of experimental overgrowth on survival and change in the turf assemblage of a giant kelp forest

    Science.gov (United States)

    Miles, A.K.; Meslow, E.C.

    1990-01-01

    Crustose coralline algae were the prevalent cover among sessile organisms that paved or grew near the substratum, and also the most commonly overgrown species in a giant kelp Macrocystis pyrifera (L.) C.A. Agardh forest located off San Nicolas Island, California. Giant kelp was the largest and most conspicuous species that overgrew large patches of the substrata; overgrowth among turf organisms also appeared common. To determine the effects of giant kelp holdfasts on crustose coralline algae and other turf organisms,'artificial holdfasts' were placed on 0.125-m2 plots for 5, 8 and 12 months. In these treatments, 50?57% of the crustose coralline algae survived. Because these algae also recruited while covered, the total cover (survivorship plus recruitment) differed by only 7?26% from that sampled at the start of the study. The decline of these algae in control plots was similar to that in the treatment plots mostly because of overgrowth by sessile invertebrates. Bryozoans increased markedly on the control plots, whereas 0?12% survived in the treatment plots. Bryozoans and sponges also recruited under the artificial holdfasts. Some arborescent turf algae survived in the 5- and 8-month treatments; articulated coralline algae survived better than did foliose algae. High survival recruitment of crustose coralline algae while overgrown contributed to their prevalence in benthic communities.

  9. A Prospective Analysis of the Injury Incidence of Young Male Professional Football Players on Artificial Turf

    Science.gov (United States)

    Bianco, Antonino; Spedicato, Mirco; Petrucci, Marco; Messina, Giuseppe; Thomas, Ewan; Nese Sahin, Fatma; Paoli, Antonio; Palma, Antonio

    2016-01-01

    Background: The effects of synthetic surfaces on the risk of injuries is still debated in literature and the majority of published data seems to be contradictory. For such reasons the understanding of injury incidence on such surfaces, especially in youth sport, is fundamental for injury prevention. Objectives: The aim of this study was to prospectively report the epidemiology of injuries in young football players, playing on artificial turfs, during a one sports season. Patients and Methods: 80 young male football players (age 16.1 ± 3.7 years; height 174 ± 6.6 cm; weight 64.2 ± 6.3 kg) were enrolled in a prospective cohort study. The participants were then divided in two groups; the first included players age ranging from 17 to 19 (OP) whereas the second included players age ranging from 13 to 16 (YP). Injury incidence was recorded prospectively, according to the consensus statement for soccer. Results: A total of 107 injuries (35 from the OP and 72 from the YP) were recorded during an exposure time of 83.760 hours (incidence 1.28/1000 per player hours); 22 during matches (incidence 2.84/1000 per player hours, 20.5%) and 85 during training (incidence 1.15/1000 per player hours, 79.5%). Thigh and groin were the most common injury locations (33.6% and 21.5%, respectively) while muscle injuries such as contractures and strains were the most common injury typologies (68.23%). No statistical differences between groups were displayed, except for the rate of severe injuries during matches, with the OP displaying slightly higher rates compared to the YP. Severe injuries accounted for 10.28% of the total injuries reported. The average time lost due to injuries was 14 days. Re-injuries accounted for 4.67% of all injuries sustained during the season. Conclusions: In professional youth soccer injury rates are reasonably low. Muscle injuries are the most common type of injuries while groin and thigh the most common locations. Artificial turf pitches don’t seem to

  10. Incidence and risk factors for turf toe injuries in intercollegiate football: data from the national collegiate athletic association injury surveillance system.

    Science.gov (United States)

    George, Elizabeth; Harris, Alex H S; Dragoo, Jason L; Hunt, Kenneth J

    2014-02-01

    Turf toe is the general term for a sprain of the first metatarsophalangeal (MTP) joint complex. Previously attributed to shoe design and artificial turf, the incidence of turf toe injury has been thought to decline with the advent of newer turf designs. However, the current incidence and epidemiology remain unknown as the majority of the literature consists of small series and addresses diagnosis and treatment rather than epidemiology and prevention. We examined data from the NCAA's Injury Surveillance System (ISS) for 5 football seasons (2004-2005 through 2008-2009), including all preseason, regular season, and postseason practice and competition data. The incidence, epidemiology, and risk factors for turf toe injury, defined as injury to the connective tissue of the first MTP joint, plantar plate complex, and/or sesamoid fracture, were determined. The overall incidence of turf toe injuries in NCAA football players was 0.062 per 1000 athlete-exposures (A-Es; 95% CI 0.052, 0.072). Athletes were nearly 14 times more likely to sustain the injury during games compared to practice, with a mean days lost due to injury of 10.1 (7.9, 12.4). Fewer than 2% of turf toe injuries required operative intervention. There was a significantly higher injury rate on third-generation artificial surfaces compared to natural grass (0.087 per 1000 A-E [0.067, 0.11] vs 0.047 per 1000 A-E [0.036, 0.059]). The majority of injuries occurred as a result of contact with the playing surface (35.4%) or contact with another player (32.7%), and running backs and quarterbacks were the most common positions to suffer turf toe injury. Our data suggest a significantly higher incidence of turf toe injuries during games, a greater susceptibility among running backs and quarterbacks, and a significant contribution of playing surface to risk of injury. Though turf toe injuries may be less common that previously reported in elite football players, these injuries warrant appropriate acute and long

  11. Angiotensin-converting enzyme

    DEFF Research Database (Denmark)

    Sørensen, P G; Rømer, F K; Cortes, D

    1984-01-01

    In order to evaluate bleomycin-associated lung damage in humans, lung function parameters and serum levels of the endothelial-bound angiotensin-converting enzyme (ACE) were determined by serial measurements in 11 patients who were treated for testicular cancer. None developed clinical or radiolog...

  12. Thermionic energy converters

    Science.gov (United States)

    Monroe, Jr., James E.

    1977-08-09

    A thermionic device for converting nuclear energy into electrical energy comprising a tubular anode spaced from and surrounding a cylindrical cathode, the cathode having an outer emitting surface of ruthenium, and nuclear fuel on the inner cylindrical surface. The nuclear fuel is a ceramic composition of fissionable material in a metal matrix. An axial void is provided to collect and contain fission product gases.

  13. Definition of Power Converters

    CERN Document Server

    Bordry, F

    2015-01-01

    The paper is intended to introduce power conversion principles and to define common terms in the domain. The concept s of sources and switches are defined and classified. From the basic laws of source interconnections, a generic method of power converter synthesis is presented. Some examples illustrate this systematic method. Finally, the commutation cell and soft commuta tion are introduced and discussedd.

  14. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  15. Influence of the mechanical properties of third-generation artificial turf systems on soccer players' physiological and physical performance and their perceptions.

    Directory of Open Access Journals (Sweden)

    Javier Sánchez-Sánchez

    Full Text Available The aim of this research was to evaluate the influence of the mechanical properties of artificial turf systems on soccer players' performance. A battery of perceptive physiological and physical tests were developed on four different structural systems of artificial turf (System 1: Compacted gravel sub-base without elastic layer; System 2: Compacted gravel sub-base with elastic layer; System 3: Asphalt sub-base without elastic layer; System 4: Asphalt sub-base with elastic layer. The sample was composed of 18 soccer players (22.44±1.72 years who typically train and compete on artificial turf. The artificial turf system with less rotational traction (S3 showed higher total time in the Repeated Sprint Ability test in comparison to the systems with intermediate values (49.46±1.75 s vs 47.55±1.82 s (S1 and 47.85±1.59 s (S2; p0.05. The physiological load was similar in all four artificial turf systems. However, players felt more comfortable on the harder and more rigid system (S4; visual analogue scale = 70.83±14.28 than on the softer artificial turf system (S2; visual analogue scale = 54.24±19.63. The lineal regression analysis revealed a significant influence of the mechanical properties of the surface of 16.5%, 15.8% and 7.1% on the mean time of the sprint, the best sprint time and the maximum mean speed in the RSA test respectively. Results suggest a mechanical heterogeneity between the systems of artificial turf which generate differences in the physical performance and in the soccer players' perceptions.

  16. Influence of the mechanical properties of third-generation artificial turf systems on soccer players' physiological and physical performance and their perceptions.

    Science.gov (United States)

    Sánchez-Sánchez, Javier; García-Unanue, Jorge; Jiménez-Reyes, Pedro; Gallardo, Ana; Burillo, Pablo; Felipe, José Luis; Gallardo, Leonor

    2014-01-01

    The aim of this research was to evaluate the influence of the mechanical properties of artificial turf systems on soccer players' performance. A battery of perceptive physiological and physical tests were developed on four different structural systems of artificial turf (System 1: Compacted gravel sub-base without elastic layer; System 2: Compacted gravel sub-base with elastic layer; System 3: Asphalt sub-base without elastic layer; System 4: Asphalt sub-base with elastic layer). The sample was composed of 18 soccer players (22.44±1.72 years) who typically train and compete on artificial turf. The artificial turf system with less rotational traction (S3) showed higher total time in the Repeated Sprint Ability test in comparison to the systems with intermediate values (49.46±1.75 s vs 47.55±1.82 s (S1) and 47.85±1.59 s (S2); p0.05). The physiological load was similar in all four artificial turf systems. However, players felt more comfortable on the harder and more rigid system (S4; visual analogue scale = 70.83±14.28) than on the softer artificial turf system (S2; visual analogue scale = 54.24±19.63). The lineal regression analysis revealed a significant influence of the mechanical properties of the surface of 16.5%, 15.8% and 7.1% on the mean time of the sprint, the best sprint time and the maximum mean speed in the RSA test respectively. Results suggest a mechanical heterogeneity between the systems of artificial turf which generate differences in the physical performance and in the soccer players' perceptions.

  17. Influence of the Mechanical Properties of Third-Generation Artificial Turf Systems on Soccer Players’ Physiological and Physical Performance and Their Perceptions

    Science.gov (United States)

    Sánchez-Sánchez, Javier; García-Unanue, Jorge; Jiménez-Reyes, Pedro; Gallardo, Ana; Burillo, Pablo; Felipe, José Luis; Gallardo, Leonor

    2014-01-01

    The aim of this research was to evaluate the influence of the mechanical properties of artificial turf systems on soccer players’ performance. A battery of perceptive physiological and physical tests were developed on four different structural systems of artificial turf (System 1: Compacted gravel sub-base without elastic layer; System 2: Compacted gravel sub-base with elastic layer; System 3: Asphalt sub-base without elastic layer; System 4: Asphalt sub-base with elastic layer). The sample was composed of 18 soccer players (22.44±1.72 years) who typically train and compete on artificial turf. The artificial turf system with less rotational traction (S3) showed higher total time in the Repeated Sprint Ability test in comparison to the systems with intermediate values (49.46±1.75 s vs 47.55±1.82 s (S1) and 47.85±1.59 s (S2); p0.05). The physiological load was similar in all four artificial turf systems. However, players felt more comfortable on the harder and more rigid system (S4; visual analogue scale = 70.83±14.28) than on the softer artificial turf system (S2; visual analogue scale = 54.24±19.63). The lineal regression analysis revealed a significant influence of the mechanical properties of the surface of 16.5%, 15.8% and 7.1% on the mean time of the sprint, the best sprint time and the maximum mean speed in the RSA test respectively. Results suggest a mechanical heterogeneity between the systems of artificial turf which generate differences in the physical performance and in the soccer players’ perceptions. PMID:25354188

  18. A Meta-Analysis of Soccer Injuries on Artificial Turf and Natural Grass

    Directory of Open Access Journals (Sweden)

    Jay H. Williams

    2013-01-01

    Full Text Available The goal of this investigation was to determine if playing or training on third-generation artificial turf (AT surfaces increases the incidence rate of injuries compared to natural grass (NG surfaces. This was accomplished by a meta-analysis performed on previously published research. Eight studies met the criteria of competitive soccer players, participation on both surfaces, and presentation of both exposure time and injury occurrence. Exposure time and injury incidence values were used to generate injury rate ratios (IRRs, AT/NG for all injuries as well as specific injuries. Subgroup analyses were also performed by condition (match or training, gender, and age (youth or adult. The overall IRR was 0.86 ( suggesting a lower injury risk on AT than NG. However, there was considerable heterogeneity between studies. Analyses of individual injuries and subgroups found that in many cases IRR values were significantly less than 1.0. In no case was the IRR significantly greater than 1.0. Based on this, it appears that the risk of sustaining an injury on AT under some conditions might be lowered compared to NG. However, until more is known about how issues such as altered playing styles affect injury incidence, it is difficult to make firm conclusions regarding the influence of AT on player safety.

  19. The microminiature thermionic converter

    Science.gov (United States)

    King, Donald B.; Luke, James R.; Zavadil, Kevin R.

    2001-02-01

    A new generation of thermionic converter, the microminiature thermionic converter (MTC) has been fabrication using semiconductor integrated circuit (IC) fabrication methods and micromachining manufacturing (MM) techniques. The use of IC and MM techniques allows the fabrication of MTCs with micron scale cathode to anode spacing and with anode and cathode materials which will have work functions ranging from 1 eV to 2.5 eV. The use of small cathode to anode spacing and variable electrode work functions gives the MTC the potential to convert heat energy to relatively large current densities (up to 10s of Amps/cm2) at relatively high conversion efficiencies (~25%), well within the range of high end conventional electrical generation equipment. Tests of prototype MTCs have demonstrated energy conversion at several emitter and collector temperatures. Power generated by the prototype MTC is less than expected because of less than optimal emission characteristics encountered with the low work function materials used for the first MTC prototypes. Work is in progress to improve the thermionic emission characteristics of the low work function electrodes. .

  20. Multilevel converters -- A new breed of power converters

    Energy Technology Data Exchange (ETDEWEB)

    Lai, J.S. [Oak Ridge National Lab., TN (United States). Engineering Technology Div.; Peng, F.Z. [Univ. of Tennessee, Knoxville, TN (United States)]|[Oak Ridge National Lab., TN (United States)

    1995-09-01

    Multilevel voltage source converters are emerging as a new breed of power converter options for high-power applications. The multilevel voltage source converters typically synthesize the staircase voltage wave from several levels of dc capacitor voltages. One of the major limitations of the multilevel converters is the voltage unbalance between different levels. The techniques to balance the voltage between different levels normally involve voltage clamping or capacitor charge control. There are several ways of implementing voltage balance in multilevel converters. Without considering the traditional magnetic coupled converters, this paper presents three recently developed multilevel voltage source converters: (1) diode-clamp, (2) flying-capacitors, and (3) cascaded-inverters with separate dc sources. The operating principle, features, constraints, and potential applications of these converters will be discussed.

  1. Biological responses of the coral Montastraea annularis to the removal of filamentous turf algae.

    Directory of Open Access Journals (Sweden)

    Neidy P Cetz-Navarro

    Full Text Available Coral reef degradation increases coral interactions with filamentous turf algae (FTA and macroalgae, which may result in chronic stress for the corals. We evaluated the effects of short (2.5 month and long (10 month periods of FTA removal on tissue thickness (TT, zooxanthellae density (ZD, mitotic index (MI, and concentration of chlorophyll a (Chl a in Montastraea annularis at the beginning and end of gametogenesis. Ramets (individual lobes within a colony consistently surrounded by FTA and ramets surrounded by crustose coralline algae (CCA were used as controls. FTA removal reduced coral stress, indicated by increased TT and ZD and lower MI. The measured effects were similar in magnitude for the short and long periods of algal removal. Ramets were more stressed at the end of gametogenesis compared with the beginning, with lower ZD and Chl a cm(-2, and higher MI. However, it was not possible to distinguish the stress caused by the presence of FTA from that caused by seasonal changes in seawater temperature. Ramets surrounded by CCA showed less stress in comparison with ramets surrounded by FTA: with higher TT, Chl a cm(-2 and ZD, and lower MI values. Coral responses indicated that ramets with FTA suffered the most deleterious effects and contrasted with those measured in ramets surrounded by CCA. According to published studies and our observations, there could be at least six mechanisms associated to FTA in the stress caused to M. annularis by FTA. Owing to the high cover of FTA (in contrast to macroalgae and CCA in the Caribbean, the chronic stress, the overgrowth and mortality that this functional algal group can cause on M. annularis species complex, a further decline of this important reef-building coral in the Caribbean is expected.

  2. EFFECTS OF ARTIFICIAL TURF AND NATURAL GRASS ON PHYSICAL AND TECHNICAL PERFORMANCE OF PROFESSIONAL SOCCER PLAYERS

    Directory of Open Access Journals (Sweden)

    Juan Carlos Ávalos Guillén

    2017-05-01

    Full Text Available The purpose of this study was to compare the effect of artificial turf (AT and natural grass (NG on the physical and technical performance of professional soccer players. A total of 17 healthy male soccer players (24.0 ± 4.1 years, height 174 ± 6.1 cm; body weight 73.4 ± 6.3 kg; body fat % 14.2 ± 2.3; VO2max 55.5 ± 5.3 ml/kg/min from a Costa Rican Professional Soccer League club were subjected to different tests in both types of surfaces (technical test, agility test, repeated sprint ability test, and a small-sided game [8 minutes, 32 x 32 meters, 5 vs. 5]. Players were monitored using a GPS in two sessions, separated by 48 hours, during the club’s pre-season. There were no significant differences between the two types of surfaces for the technical, agility, and repeated sprint ability tests. The physiological and kinematic variables analyzed during the small-sided game presented significant differences in average heart rate (NG = 168.5 ± 8.8, AT = 154.8 ± 11.8, p <.001, maximum heart rate (NG = 183.2 ± 8.3, AT = 175.9 ± 10.4, p =.02, body load (NG = 34.3 ± 11.2, AT = 30.5 ± 11.4, p =.03, and total impacts (NG = 230.1 ± 89.5, AT = 194. 8 ± 86.4, p=.03. It is concluded that playing on the natural grass surface caused more impact on physiological and perceived body load in players. In the case of technical variables, it is concluded that there were no statistically significant differences between the two types of surfaces (p <0.05.

  3. Biological responses of the coral Montastraea annularis to the removal of filamentous turf algae.

    Science.gov (United States)

    Cetz-Navarro, Neidy P; Espinoza-Avalos, Julio; Hernández-Arana, Héctor A; Carricart-Ganivet, Juan P

    2013-01-01

    Coral reef degradation increases coral interactions with filamentous turf algae (FTA) and macroalgae, which may result in chronic stress for the corals. We evaluated the effects of short (2.5 month) and long (10 month) periods of FTA removal on tissue thickness (TT), zooxanthellae density (ZD), mitotic index (MI), and concentration of chlorophyll a (Chl a) in Montastraea annularis at the beginning and end of gametogenesis. Ramets (individual lobes within a colony) consistently surrounded by FTA and ramets surrounded by crustose coralline algae (CCA) were used as controls. FTA removal reduced coral stress, indicated by increased TT and ZD and lower MI. The measured effects were similar in magnitude for the short and long periods of algal removal. Ramets were more stressed at the end of gametogenesis compared with the beginning, with lower ZD and Chl a cm(-2), and higher MI. However, it was not possible to distinguish the stress caused by the presence of FTA from that caused by seasonal changes in seawater temperature. Ramets surrounded by CCA showed less stress in comparison with ramets surrounded by FTA: with higher TT, Chl a cm(-2) and ZD, and lower MI values. Coral responses indicated that ramets with FTA suffered the most deleterious effects and contrasted with those measured in ramets surrounded by CCA. According to published studies and our observations, there could be at least six mechanisms associated to FTA in the stress caused to M. annularis by FTA. Owing to the high cover of FTA (in contrast to macroalgae and CCA) in the Caribbean, the chronic stress, the overgrowth and mortality that this functional algal group can cause on M. annularis species complex, a further decline of this important reef-building coral in the Caribbean is expected.

  4. X-Y Converter Family

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Sanjeevikumar, Padmanaban; Wheeler, Patrick

    2016-01-01

    A New breed of a buck boost converter, named as the XY converter family is proposed in this article. In the XY family, 16 topologies are presented which are highly suitable for renewable energy applications which require a high ratio of DC-DC converter; such as a photovoltaic multilevel inverter...... system, high voltage automotive applications and industrial drives. Compared to the traditional boost converter and existing recent converters, the proposed XY converter family has the ability to provide a higher output voltage by using less number of power devices and reactive components. Other distinct...... features of the XY converter family are i) Single control switch ii) Provide negative output voltage iii) Non-isolated topologies iv) High conversion ratio without making the use of high duty cycle and v) modular structure. XY family is compared with the recent high step-up converters and the detailed...

  5. Feedbacks between vegetation and solifluction processes on hillslopes: a case study of an alpine turf-banked solifluction lobe

    Science.gov (United States)

    Eichel, Jana; Draebing, Daniel; Wieland, Markus; Eling, Christian; Klingbeil, Lasse; Dikau, Richard

    2015-04-01

    Solifluction is one of the most widespread processes transporting soil on hillslopes in periglacial environments. While periglacial geomorphologists identified climatic and soil parameters as most important factors influencing solifluction, ecologist have long recognized the importance of vegetation and the co-occurrence of certain species and vegetation communities with solifluction processes and landforms. However, the mechanism of vegetation influences on solifluction, as well as feedbacks between solifluction processes and vegetation, which result in specific vegetation organization and specific landforms, e.g., turf-banked solifluction lobes, is only partly understood. The aim of our study is to improve the understanding of feedbacks between vegetation and solifluction processes and landforms by using established and up-to-date methods in a detailed small-scale study on a turf-banked solifluction lobe in the Turtmann glacier forefield (Switzerland). Our objectives are (i) to examine the effects of species composition and vegetation organization on landform properties; (ii) to investigate the effects of landform properties on species composition and vegetation organization and (iii) to evaluate if feedbacks create turf-banked solifluction lobes as biogeomorphic structures. To assess solifluction lobe and vegetation properties, we employed a detailed geomorphic and vegetation mapping (1:50), complemented by an UAV derived high-resolution orthophoto and DEM, and 2D and 3D electrical resistivity tomography (ERT) measurements in combination with soil moisture measurements. Vegetation mapping shows that (i) dwarf shrubs, which through their plant functional traits can act as engineer species, are the main species covering the solifluction lobe. Geomorphic mapping, DEM terrain analyses and 3D ERT indicate that (ii) lobe geomorphometry and material properties (grain size, moisture) strongly influence species distribution and diversity. 2D ERT shows permafrost

  6. The Effect of Varying Speed Release of Nutrients from Fertilizers on Growth-production Process of Turf

    Directory of Open Access Journals (Sweden)

    Peter Hric

    2016-01-01

    Full Text Available The aim of this experiment was to compare the influence of fertilizers with different speed of nutrients release on growth–production indicators of turf under non–irrigated conditions. The experiment was carried in warm and dry conditions in area Nitra (Slovak Republic. In the experiment were followed 5 treatments (1. without fertilization, 2. Nitre with dolomite, Superphosphate, Potassium salt, 3. Turf fertilizer Travcerit®, 4. Slow release fertilizer SRF NPK 14–5–14 (+ 4CaO + 4MgO + 7S, 5. Controlled release fertilizer Duslocote® NPK (S 13–9–18 (+6S. The highest gain of height reached variant fertilized by fertilizer SRF NPK 14–5–14 (+ 4CaO + 4MgO + 7S. Comparison of the individual treatments for the whole period showed significantly lower average daily gains of height on control treatment compared to fertilizing treatments Nitre with dolomite, Superphosphate, Potassium salt, SRF NPK 14–5–14 (+ 4CaO + 4MgO + 7S and Duslocote® NPK (S 13–9–18 (+6S. During the reported period the highest gain of weight reached treatment by application fertilizer Duslocote® NPK (S 13– 9–18 (+ 6S. Comparison of the individual treatments for the whole period, were found significantly lower average daily production of phytomass on control treatment in comparison with fertilization turfs by Travcerit® and Duslocote® NPK (S 13–9–18 (+6S.

  7. Cycloidal Wave Energy Converter

    Energy Technology Data Exchange (ETDEWEB)

    Stefan G. Siegel, Ph.D.

    2012-11-30

    This program allowed further advancing the development of a novel type of wave energy converter, a Cycloidal Wave Energy Converter or CycWEC. A CycWEC consists of one or more hydrofoils rotating around a central shaft, and operates fully submerged beneath the water surface. It operates under feedback control sensing the incoming waves, and converts wave power to shaft power directly without any intermediate power take off system. Previous research consisting of numerical simulations and two dimensional small 1:300 scale wave flume experiments had indicated wave cancellation efficiencies beyond 95%. The present work was centered on construction and testing of a 1:10 scale model and conducting two testing campaigns in a three dimensional wave basin. These experiments allowed for the first time for direct measurement of electrical power generated as well as the interaction of the CycWEC in a three dimensional environment. The Atargis team successfully conducted two testing campaigns at the Texas A&M Offshore Technology Research Center and was able to demonstrate electricity generation. In addition, three dimensional wave diffraction results show the ability to achieve wave focusing, thus increasing the amount of wave power that can be extracted beyond what was expected from earlier two dimensional investigations. Numerical results showed wave cancellation efficiencies for irregular waves to be on par with results for regular waves over a wide range of wave lengths. Using the results from previous simulations and experiments a full scale prototype was designed and its performance in a North Atlantic wave climate of average 30kW/m of wave crest was estimated. A full scale WEC with a blade span of 150m will deliver a design power of 5MW at an estimated levelized cost of energy (LCOE) in the range of 10-17 US cents per kWh. Based on the new results achieved in the 1:10 scale experiments these estimates appear conservative and the likely performance at full scale will

  8. Resonant power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2012-01-01

    This book is devoted to resonant energy conversion in power electronics. It is a practical, systematic guide to the analysis and design of various dc-dc resonant inverters, high-frequency rectifiers, and dc-dc resonant converters that are building blocks of many of today's high-frequency energy processors. Designed to function as both a superior senior-to-graduate level textbook for electrical engineering courses and a valuable professional reference for practicing engineers, it provides students and engineers with a solid grasp of existing high-frequency technology, while acquainting them wit

  9. The effect of filamentous turf algal removal on the development of gametes of the coral Orbicella annularis.

    Directory of Open Access Journals (Sweden)

    Neidy P Cetz-Navarro

    Full Text Available Macroalgae and filamentous turf algae (FTA are abundant on degraded coral reefs, and the reproductive responses of corals may indicate sub-lethal stress under these conditions. The percentage of gametogenic stages (PGS and the maximum diameter of eggs (MDE; or egg size of Orbicella annularis were used to evaluate the effect of long- (7-10 months and short-term (2.5 months FTA removal (treatments T1 and T2, respectively at both the beginning (May and the end (August of gametogenesis. Ramets (individual lobes of a colony surrounded by FTA (T3 or crustose coralline algae (CCA; T4 were used as controls. The removal of FTA enhanced the development of gametes (i.e., a larger and higher percentage of mature gametes (PMG of O. annularis for T1 vs. T3 ramets in May and T1 and T2 vs. T3 ramets in August. Similar values of PGS and MDE between gametes from T3 and T4 in both May and August were unexpected because a previous study had shown that the same ramets of T4 (with higher tissue thickness, chlorophyll a cm-2 and zooxanthellae density and lower mitotic index values were less stressed than ramets of T3. Evaluating coral stress through reproduction can reveal more sensitive responses than other biological parameters; within reproductive metrics, PGS can be a better stress indicator than egg size. The presence of turf algae strongly impacted the development of gametes and egg size (e.g., PMG in ramets with FTA removal increased almost twofold in comparison with ramets surrounded by FTA in August, most likely exerting negative chronic effects in the long run due to the ubiquity and permanence of turf algae in the Caribbean. These algae can be considered a stressor that affects coral sexual reproduction. Although the effects of turf algae on O. annularis are apparently less severe than those of other stressors, the future of this species is uncertain because of the combined impacts of these effects, the decline of O. annularis populations and the almost

  10. The effect of filamentous turf algal removal on the development of gametes of the coral Orbicella annularis.

    Science.gov (United States)

    Cetz-Navarro, Neidy P; Carpizo-Ituarte, Eugenio J; Espinoza-Avalos, Julio; Chee-Barragán, Guillermina

    2015-01-01

    Macroalgae and filamentous turf algae (FTA) are abundant on degraded coral reefs, and the reproductive responses of corals may indicate sub-lethal stress under these conditions. The percentage of gametogenic stages (PGS) and the maximum diameter of eggs (MDE; or egg size) of Orbicella annularis were used to evaluate the effect of long- (7-10 months) and short-term (2.5 months) FTA removal (treatments T1 and T2, respectively) at both the beginning (May) and the end (August) of gametogenesis. Ramets (individual lobes of a colony) surrounded by FTA (T3) or crustose coralline algae (CCA; T4) were used as controls. The removal of FTA enhanced the development of gametes (i.e., a larger and higher percentage of mature gametes (PMG)) of O. annularis for T1 vs. T3 ramets in May and T1 and T2 vs. T3 ramets in August. Similar values of PGS and MDE between gametes from T3 and T4 in both May and August were unexpected because a previous study had shown that the same ramets of T4 (with higher tissue thickness, chlorophyll a cm-2 and zooxanthellae density and lower mitotic index values) were less stressed than ramets of T3. Evaluating coral stress through reproduction can reveal more sensitive responses than other biological parameters; within reproductive metrics, PGS can be a better stress indicator than egg size. The presence of turf algae strongly impacted the development of gametes and egg size (e.g., PMG in ramets with FTA removal increased almost twofold in comparison with ramets surrounded by FTA in August), most likely exerting negative chronic effects in the long run due to the ubiquity and permanence of turf algae in the Caribbean. These algae can be considered a stressor that affects coral sexual reproduction. Although the effects of turf algae on O. annularis are apparently less severe than those of other stressors, the future of this species is uncertain because of the combined impacts of these effects, the decline of O. annularis populations and the almost complete

  11. Nutrient loss with runoff from fairway turf: an evaluation of core cultivation practices and their environmental impact.

    Science.gov (United States)

    Rice, Pamela J; Horgan, Brian P

    2011-11-01

    The presence of excess nutrients in surface waters can result in undesirable environmental and economic consequences, including nuisance algal blooms and eutrophication. Fertilizer use in highly managed turf systems has raised questions concerning the contribution of nutrients to surrounding surface waters. Experiments were designed to quantify phosphorus and nitrogen transport with runoff from turf plots maintained as a golf course fairway to identify which cultural practice, solid tine (ST) or hollow tine (HT) core cultivation, maximized phosphorus and nitrogen retention at the site of fertilizer application. Simulated precipitation and collection of resulting runoff were completed 26 ± 13 h following granular fertilizer application (18-3-18: N-P₂O₅-K₂O) and 63 d and 2 d following core cultivation. Runoff volumes were reduced in fairway turf plots aerated with HT relative to ST (63 d: 10%, 2 d: 55% reduction). Analysis of the runoff revealed a reduction in soluble phosphorus, ammonium nitrogen, and nitrate nitrogen losses with runoff from plots managed with HT; a 5 to 27% reduction after 63 d; and a 39 to 77% reduction at 2 d. Golf course runoff-to-surface water scenarios were used to calculate estimated environmental concentrations (EECs) of nitrogen and phosphorus in surface water receiving runoff from turf managed with ST or HT core cultivation. Surface water concentrations of phosphorus remained above the U.S. Environmental Protection Agency's water quality criteria to limit eutrophication, with the exception of concentrations associated with HT core cultivation at 2 d. Regardless of management practice (ST or HT) and time between core cultivation and runoff (63 d or 2 d), all EECs of nitrogen were below levels associated with increased algal growth. Understanding nutrient transport with runoff and identifying strategies that reduce off-site transport will increase their effectiveness at intended sites of application and

  12. Bidirectional DC/DC Converter

    Science.gov (United States)

    Pedersen, F.

    2008-09-01

    The presented bidirectional DC/DC converter design concept is a further development of an already existing converter used for low battery voltage operation.For low battery voltage operation a high efficient low parts count DC/DC converter was developed, and used in a satellite for the battery charge and battery discharge function.The converter consists in a bidirectional, non regulating DC/DC converter connected to a discharge regulating Buck converter and a charge regulating Buck converter.The Bidirectional non regulating DC/DC converter performs with relatively high efficiency even at relatively high currents, which here means up to 35Amps.This performance was obtained through the use of power MOSFET's with on- resistances of only a few mille Ohms connected to a special transformer allowing paralleling several transistor stages on the low voltage side of the transformer. The design is patent protected. Synchronous rectification leads to high efficiency at the low battery voltages considered, which was in the range 2,7- 4,3 Volt DC.The converter performs with low switching losses as zero voltage zero current switching is implemented in all switching positions of the converter.Now, the drive power needed, to switch a relatively large number of low Ohm , hence high drive capacitance, power MOSFET's using conventional drive techniques would limit the overall conversion efficiency.Therefore a resonant drive consuming considerable less power than a conventional drive circuit was implemented in the converter.To the originally built and patent protected bidirectional non regulating DC/DC converter, is added the functionality of regulation.Hereby the need for additional converter stages in form of a Charge Buck regulator and a Discharge Buck regulator is eliminated.The bidirectional DC/DC converter can be used in connection with batteries, motors, etc, where the bidirectional feature, simple design and high performance may be useful.

  13. Fluorescent radiation converter

    Science.gov (United States)

    Viehmann, W. (Inventor)

    1981-01-01

    A fluorescence radiation converter is described which includes a substantially undoped optically transparent substrate and a waveshifter coating deposited on at least one portion of the substrate for absorption of radiation and conversion of fluorescent radiation. The coating is formed to substantially 1000 g/liter of a solvent, 70 to 200 g/liter of an organic polymer, and 0.2 to 25 g/liter of at least one organic fluorescent dye. The incoming incident radiation impinges on the coating. Radiation is absorbed by the fluorescent dye and is re-emitted as a longer wavelength radiation. Radiation is trapped within the substrate and is totally internally reflected by the boundary surface. Emitted radiation leaves the substrate ends to be detected.

  14. Electromagnetic wave energy converter

    Science.gov (United States)

    Bailey, R. L. (Inventor)

    1973-01-01

    Electromagnetic wave energy is converted into electric power with an array of mutually insulated electromagnetic wave absorber elements each responsive to an electric field component of the wave as it impinges thereon. Each element includes a portion tapered in the direction of wave propagation to provide a relatively wideband response spectrum. Each element includes an output for deriving a voltage replica of the electric field variations intercepted by it. Adjacent elements are positioned relative to each other so that an electric field subsists between adjacent elements in response to the impinging wave. The electric field results in a voltage difference between adjacent elements that is fed to a rectifier to derive dc output power.

  15. Integrated power electronic converters and digital control

    CERN Document Server

    Emadi, Ali; Nie, Zhong

    2009-01-01

    Non-isolated DC-DC ConvertersBuck ConverterBoost ConverterBuck-Boost ConverterIsolated DC-DC ConvertersFlyback ConverterForward ConverterPush-Pull ConverterFull-Bridge ConverterHalf-Bridge ConverterPower Factor CorrectionConcept of PFCGeneral Classification of PFC CircuitsHigh Switching Frequency Topologies for PFCApplication of PFC in Advanced Motor DrivesIntegrated Switched-Mode Power ConvertersSwitched-Mode Power SuppliesThe Concept of Integrated ConverterDefinition of Integrated Switched-Mode Power Supplies (ISMPS)Boost-Type Integrated TopologiesGeneral Structure of Boost-Type Integrated T

  16. Advanced power electronics converters PWM converters processing AC voltages

    CERN Document Server

    dos Santos, Euzeli

    2014-01-01

    This book covers power electronics, in depth, by presenting the basic principles and application details, which can be used both as a textbook and reference book.  Introduces a new method to present power electronics converters called Power Blocks Geometry. Applicable for courses focusing on power electronics, power electronics converters, and advanced power converters. Offers a comprehensive set of simulation results to help understand the circuits presented throughout the book

  17. Impedance source power electronic converters

    CERN Document Server

    Liu, Yushan; Ge, Baoming; Blaabjerg, Frede; Ellabban, Omar; Loh, Poh Chiang

    2016-01-01

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding control methods. Presents the latest power conversion solutions that aim to advance the role of pow...

  18. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well......Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...

  19. Genetic characterization of Kyrgyzstan fine-leaved Festuca valesiaca germplasm for use in semi-arid low-maintenance turf applications

    Science.gov (United States)

    Fine-leaved Festuca valesiaca Shleidcher ex. Gaudin (2n = 2x-4x) is native to heavily grazed, cold, semi-arid, Asian rangelands. However, its potential for low-maintenance turf applications in the semi-arid western United States and its relatedness to other agriculturally important Festuca species ...

  20. Athletes’ Selected Micro-Activities on Turf Fields: Utilizing Extant Videography for Quantification of Events During Soccer, American Football, and Field Hockey Play

    Science.gov (United States)

    Concerns have been recently raised about the potential exposures of athletes to chemicals when playing on synthetic turf fields. Previous research has shown that micro-activities (i.e., hand-to mouth and skin-to-surface contacts) are important factors in people’s exposures to che...

  1. Endocrine-disrupting compounds in reclaimed water and residential ponds and exposure potential for dislodgeable residues in turf irrigated with reclaimed water.

    Science.gov (United States)

    Sidhu, Harmanpreet S; Wilson, Patrick C; O'Connor, George A

    2015-07-01

    Endocrine-disrupting chemicals (EDCs) occur in reclaimed water (RW), which may serve as an exposure source for humans. The presence of EDCs in RW used to irrigate turf and in nearby water-retention ponds was determined. In addition, the total dislodgeable mass of each EDC was determined after irrigation (using RW) to simulate exposure of a 3-year-child playing in turf grass recently irrigated with RW. Five EDCs (estrone, 17β-estradiol, 17α-ethynylestradiol, bisphenol A, and 4-n-nonylphenol) were quantified in 28 samples of RWs (wastewater-treatment plant effluents) and 88 samples from residential surface water-retention ponds. St. Augustine variety of turf grass was irrigated with spiked RW to study dislodgement of the five EDCs overtime using a drag-sled method. Grass clippings were analyzed to relate masses of EDC on grass with masses dislodged. EDCs were detected in both RW and ponds at ng/L concentrations. Maximum EDC masses were dislodged immediately after irrigation. Dislodged masses of estrone and 17β-estradiol are two separate EDCs, 17β-estradiol and 17α-ethynylestradiol decreased rapidly and were lower than detection limits 4 h after application. Dislodged bisphenol-A and nonylphenol decreased more slowly but were not detected 6 h after application. Avoiding contact with recently irrigated turf grass should decrease the risks of exposure to these EDCs.

  2. Grazing Effects of Fish versus Sea Urchins on Turf Algae and Coral Recruits: Possible Implications for Coral Reef Resilience and Restoration

    Directory of Open Access Journals (Sweden)

    Leor Korzen

    2011-01-01

    Full Text Available Herbivory is an important structuring factor in coral reefs, influencing seaweed abundance, competitive interactions between seaweeds and corals, and coral reef resilience. Despite reports of a drastic increase in the cover of benthic algae and turf dominancy in the coral reefs of Eilat, Red Sea, very little is known about the factors responsible for this phenomenon or the possible effects of herbivory on turf algae and coral recruits. Here, we examine the effects of herbivory by experimentally exposing turf algae and coral recruits to grazing activities of herbivorous fish and sea urchins. Using remote video cameras to document removal of algae and coral spats, we show that the main grazing impact is due to daily grazing by fishes, whereas the significant impact of sea urchins is mainly expressed in their adverse effect on the survival of coral recruits, with a relatively low effect on algal biomass. These findings contribute to our understanding of the factors influencing turf algae establishment and proliferation, and the survival of coral recruits on the coral reefs of Eilat. The clear differences between the impact of herbivorous fish and that of sea urchins, on the Eilat reefs, have critical implications for reef resilience and restoration measures.

  3. Expression in yeast of the T-urf13 protein from Texas male-sterile maize mitochondria confers sensitivity to methomyl and to Texas-cytoplasm-specific fungal toxins.

    Science.gov (United States)

    Huang, J; Lee, S H; Lin, C; Medici, R; Hack, E; Myers, A M

    1990-01-01

    The mitochondrial gene T-urf13 from maize (Zea mays L.) with Texas male-sterile (T) cytoplasm codes for a unique 13 kd polypeptide, T-URF13, which is implicated in cytoplasmic male sterility and sensitivity to the insecticide methomyl and to host-specific fungal toxins produced by Helminthosporium maydis race T (HmT toxin) and Phyllosticta maydis (Pm toxin). A chimeric gene coding for T-URF13 fused to the mitochondrial targeting peptide from the Neurospora crassa ATP synthase subunit 9 precursor was constructed. Expression of this gene in the yeast Saccharomyces cerevisiae yielded a polypeptide that was translocated into the membrane fraction of mitochondria and processed to give a protein the same size as maize T-URF13. Methomyl, HmT toxin and Pm toxin inhibited growth of yeast cells expressing the gene fusion on medium containing glycerol as sole carbon source and stimulated respiration with NADH as substrate by isolated mitochondria from these cells. These effects were not observed in yeast cells expressing T-URF13 without a targeting peptide. The results show that T-URF13 is sufficient to confer sensitivity to methomyl and the fungal toxins in a heterologous eukaryotic system, and suggest that mitochondrial localization of T-URF13 is critical for these functions. Images Fig. 2. Fig. 3. Fig. 5. PMID:2303028

  4. Controlling factors of turf-banked solifluction lobe evolution in the Turtmann glacier forefield (Switzerland)

    Science.gov (United States)

    Draebing, Daniel; Eichel, Jana

    2016-04-01

    Soil structure and moisture, thermal conditions and vegetation control solifluction movement, however, the spatial distribution of controlling factors and resultant spatial variability of movement are poorly understood. We use a (1) geomorphological and vegetation mapping of solifluction lobe properties, (2) temperature loggers to quantify thermal conditions, (3) 2D Electrical Resistivity Tomography (ERT), Puerkhauer drilling and TDR measurements to evaluate material properties as well as (4) 3D Time-Lapse ERT to quantify spatial variability of material properties. Our results are used to (5) evaluate the influence of potential controlling factors on solifluction movement. Investigations took place on three turf-banked lobes (TBL) located at proximal and distal slopes of Little Ice Age and 1920s lateral moraines in the Turtmann glacier forefield, Swiss Alps. (1) Vegetation is spatially differentiated at TBLs. The treads are mostly covered by the ecosystem engineer Dryas octopetala, while other dwarf shrubs, shrubs and pioneer species were found at the high lobe risers (0.8-1.8 m). In contrast, less vegetated ridge-like features at the upper part of the treads are colonized by frost-tolerant species. Large blocks are located at the lobe fronts, probably impeding the lobe movement. (2) Temperature loggers show a lack of ground cooling due to snow isolation at the vegetated lower tread between 2014 and 2015. Thus, significant ground cooling in winter is reduced to the wind-exposed upper parts (ridges). (3) TBL material consists of sandy silt, thus, lobe material is much finer than subjacent moraine till and indicates former colluviation. As a consequence, 2D ERT demonstrates low-resistant areas until depths equal to riser height, thus, the finer TBL body is higher saturated than the coarser surrounding parent slope and more susceptible to gelifluction. On the contrary, risers show high resistivities indicating dry conditions which are supported by TDR results

  5. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well......Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...

  6. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key......Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well...

  7. Comparative kinematic analysis of the leading and trailing forelimbs of horses cantering on a turf and a synthetic surface.

    Science.gov (United States)

    Crevier-Denoix, N; Falala, S; Holden-Douilly, L; Camus, M; Martino, J; Ravary-Plumioen, B; Vergari, C; Desquilbet, L; Denoix, J-M; Chateau, H; Pourcelot, P

    2013-12-01

    The relationship between track surface properties and limb kinematics is poorly understood. Hoof orientation within the track surface has never been quantified under training conditions. Previously described kinematic and dynamic differences between leading and trailing forelimbs at the canter poorly correlate with epidemiological data regarding injuries. To compare joint kinematics and hoof orientation in the leading and trailing forelimbs of horses cantering on turf and on a synthetic surface. Noninvasive experimental study. The right forelimb of 5 horses was equipped with markers facing the main joints while markers and a dynamometric horseshoe were placed on the hoof. The horses were filmed with 2 high-speed cameras (1000 Hz) while cantering (30 km/h). Recordings were repeated at each lead and alternated on turf and on a synthetic surface. Joint angles and angles of the hoof and limb to the track were measured from the 2-dimensional coordinates of the markers. Elbow, carpus and fetlock were more maximally flexed during swing and had a larger range of motion throughout the stride in the leading forelimb. Maximal carpal extension during stance was also larger on this limb, which had a more toe-up orientation. Comparing surfaces, the limb was more oblique at landing, the range of motion of the hoof into the surface was larger, most kinematic events were delayed and fetlock and carpus extension velocities were smaller on the synthetic surface. The differences between limbs were more prominent than those between surfaces and the more toe-up orientation on the hoof of the leading forelimb suggests a different loading of that limb's joints and tendons. Differences between limbs may be important in the interpretation of lead changes in lame horses. While the synthetic surface appears to be less strenuous for the joints in the forelimbs, it was associated with changes in timing of the kinematic events of the stride. © 2013 EVJ Ltd.

  8. Radiation tolerant power converter controls

    CERN Document Server

    Todd, B; King, Q; Uznanski, S

    2012-01-01

    The Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is the world's most powerful particle collider. The LHC has several thousand magnets, both warm and super-conducting, which are supplied with current by power converters. Each converter is controlled by a purpose-built electronic module called a Function Generator Controller (FGC). The FGC allows remote control of the power converter and forms the central part of a closed-loop control system where the power converter voltage is set, based on the converter output current and magnet-circuit characteristics. Some power converters and FGCs are located in areas which are exposed to beam-induced radiation. There are numerous radiation induced effects, some of which lead to a loss of control of the power converter, having a direct impact upon the accelerator's availability. Following the first long shut down (LS1), the LHC will be able to run with higher intensity beams and higher beam energy. This is expected to lead to signifi...

  9. New fault tolerant matrix converter

    Energy Technology Data Exchange (ETDEWEB)

    Ibarra, Edorta; Andreu, Jon; Kortabarria, Inigo; Ormaetxea, Enekoitz; Alegria, Inigo Martinez de; Martin, Jose Luis [Department of Electronics and Telecommunications, University of the Basque Country, Alameda de Urquijo s/n, E-48013 Bilbao (Spain); Ibanez, Pedro [TECNALIA, Energy Unit, Parque Tecnologico de Zamudio, E-48170 Bizkaia (Spain)

    2011-02-15

    The matrix converter (MC) presents a promising topology that will have to overcome certain barriers (protection systems, durability, the development of converters for real applications, etc.) in order to gain a foothold in the industry. In some applications, where continuous operation must be insured in the case of a system failure, improved reliability of the converter is of particular importance. In this sense, this article focuses on the study of a fault tolerant MC. The fault tolerance of a converter is characterized by its total or partial response in the case of a breakage of any of its components. Taking into consideration that virtually no work has been done on fault tolerant MCs, this paper describes the most important studies in this area. Moreover, a new method is proposed for detecting the breakage of MC semiconductors. Likewise, a new variation of SVM modulation with failure tolerance capacity is presented. This guarantees the continuous operation of the converter and the pseudo-optimum control of a PMSM. This paper also proposes a novel MC topology, which allows the flexible reconfiguration of this converter, when one or several of its semiconductors are damaged. In this way, the MC can continue operating at 100% of its performance without having to double its resources. In this way, it can be said that the solution described in this article represents a step forward towards the development of reliable matrix converters for real applications. (author)

  10. Multilevel converters for industrial applications

    CERN Document Server

    Gonzalez, Sergio Alberto

    2013-01-01

    Modern semiconductor devices have reached high current and voltage levels, and their power-handling limits can be extended if they are used in multilevel converter configurations. To create high-performance and reliable control designs, however, engineers need in-depth understanding of the characteristics and operation of these topologies. Multilevel Converters for Industrial Applications presents a thorough and comprehensive analysis of multilevel converters with a common DC voltage source. The book offers a novel perspective to help readers understand the principles of the operation of volta

  11. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well...... as different industrial applications. Provides an overview of existing challenges, solutions and future trends. Supported by calculation examples, simulation models and results....

  12. Wind/water energy converter

    Science.gov (United States)

    Paulkovich, J.

    1979-01-01

    Device will convert wind, water, tidal or wave energy into electrical or mechanical energy. Is comprised of windmill-like paddles or blades synchronously geared to orient themselves to wind direction for optimum energy extraction.

  13. Time-to-digital converters

    CERN Document Server

    Henzler, Stephan

    2010-01-01

    This text covers the fundamentals of time-to-digital converters on analog and digital conversion principles. It includes a theoretical investigation into quantization, linearity, noise and variability, and it details a range of advanced TDC architectures.

  14. Analog-to-digital converter

    Science.gov (United States)

    Lewyn, L. L. (Inventor)

    1965-01-01

    An analog to digital converter circuit arrangement is reported that is suitable for use in ultra fast pulse height analysis. The circuit uses series connected tunnel diodes to quantize a voltage signal into discrete levels.

  15. Laser system with wavelength converter

    DEFF Research Database (Denmark)

    2012-01-01

    The present invention relates to an apparatus comprising a diode laser (10) providing radiation in a first wavelength interval, a radiation conversion unit (12) having an input and an output, the radiation converter configured to receive the radiation in the first wavelength interval from the diode...... laser at the input, the radiation conversion unit configured to convert the radiation in the first wavelength interval to radiation in a second wavelength interval and the output configured to output the converted radiation, the second wavelength interval having one end point outside the first...... wavelength interval. Further, the invention relates to a method of optically pumping a target laser (14) in a laser system, the laser system comprising a laser source providing radiation at a first frequency, the laser source being optically connected to an input of a frequency converter, the frequency...

  16. Radiation tolerant power converter controls

    Science.gov (United States)

    Todd, B.; Dinius, A.; King, Q.; Uznanski, S.

    2012-11-01

    The Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is the world's most powerful particle collider. The LHC has several thousand magnets, both warm and super-conducting, which are supplied with current by power converters. Each converter is controlled by a purpose-built electronic module called a Function Generator Controller (FGC). The FGC allows remote control of the power converter and forms the central part of a closed-loop control system where the power converter voltage is set, based on the converter output current and magnet-circuit characteristics. Some power converters and FGCs are located in areas which are exposed to beam-induced radiation. There are numerous radiation induced effects, some of which lead to a loss of control of the power converter, having a direct impact upon the accelerator's availability. Following the first long shut down (LS1), the LHC will be able to run with higher intensity beams and higher beam energy. This is expected to lead to significantly increased radiation induced effects in materials close to the accelerator, including the FGC. Recent radiation tests indicate that the current FGC would not be sufficiently reliable. A so-called FGClite is being designed to work reliably in the radiation environment in the post-LS1 era. This paper outlines the concepts of power converter controls for machines such as the LHC, introduces the risks related to radiation and a radiation tolerant project flow. The FGClite is then described, with its key concepts and challenges: aiming for high reliability in a radiation field.

  17. Boron nitride converted carbon fiber

    Science.gov (United States)

    Rousseas, Michael; Mickelson, William; Zettl, Alexander K.

    2016-04-05

    This disclosure provides systems, methods, and apparatus related to boron nitride converted carbon fiber. In one aspect, a method may include the operations of providing boron oxide and carbon fiber, heating the boron oxide to melt the boron oxide and heating the carbon fiber, mixing a nitrogen-containing gas with boron oxide vapor from molten boron oxide, and converting at least a portion of the carbon fiber to boron nitride.

  18. Current status of converter steelmaking

    Energy Technology Data Exchange (ETDEWEB)

    Oghbasialasie, H.; Holappa, L.

    1995-12-31

    This literature work is mainly focusing on the mechanisms of modern converter steelmaking and related with the evaluation of converter technology applied during the last decades and further to the future. The history of steelmaking has been briefly reviewed from bloomeries and early-steelmaking processes to the progress of modern converter process. The pneumatic converter processes were developed in the 1850`s and thereafter the basis for the rapid growth of steel industries was established for the next 100 years. The world production of steel has not continuously grown but fluctuating quite much. It reached 723 Mt in 1994. The production is believed to grow the forecast for the year 2003 being approximately 800 Mt. Electric arc furnace production is estimated to reach 280 Mt by 2003, and BOFIOH will reach 520 Mt by 2003. The current status of the converter steelmaking process is briefly described both on its theoretical bases and practical technological progresses. Developments which significantly improve the process are briefly discussed. Several more recent developments such as combined oxygen blowing process, increased scrap melting, post combustion and hot metal pretreatment are discussed. The future progress will be in further development of these process characteristics as well as in eventual emerging of the continuous converter process. (author)

  19. The Simulation of DFIG Grid Side Converter

    National Research Council Canada - National Science Library

    LU Yan-Ling; LU Jian-qiang; BAO Jie

    2017-01-01

    Firstly,DFIG basic structure of grid side converter was analyzed according to basic principles of voltage converter, and a mathematical model of grid side converter was established in the three-phase...

  20. Transplantation of subalpine wood-pasture turfs along a natural climatic gradient reveals lower resistance of unwooded pastures to climate change compared to wooded ones.

    Science.gov (United States)

    Gavazov, Konstantin; Spiegelberger, Thomas; Buttler, Alexandre

    2014-04-01

    Climate change could impact strongly on cold-adapted mountain ecosystems, but little is known about its interaction with traditional land-use practices. We used an altitudinal gradient to simulate a year-round warmer and drier climate for semi-natural subalpine grasslands across a landscape of contrasting land-use management. Turf mesocosms from three pasture-woodland land-use types-unwooded pasture, sparsely wooded pasture, and densely wooded pasture-spanning a gradient from high to low management intensity were transplanted downslope to test their resistance to two intensities of climate change. We found strong overall effects of intensive (+4 K) experimental climate change (i.e., warming and reduced precipitation) on plant community structure and function, while moderate (+2 K) climate change did not substantially affect the studied land-use types, thus indicating an ecosystem response threshold to moderate climate perturbation. The individual land-use types were affected differently under the +4 K scenario, with a 60% decrease in aboveground biomass (AGB) in unwooded pasture turfs, a 40% decrease in sparsely wooded pasture turfs, and none in densely wooded ones. Similarly, unwooded pasture turfs experienced a 30% loss of species, advanced (by 30 days) phenological development, and a mid-season senescence due to drought stress, while no such effects were recorded for the other land-use types. The observed contrasting effects of climate change across the pasture-woodland landscape have important implications for future decades. The reduced impact of climate change on wooded pastures as compared to unwooded ones should promote the sustainable land use of wooded pastures by maintaining low management intensity and a sparse forest canopy, which buffer the immediate impacts of climate change on herbaceous vegetation.

  1. Modeling of asymmetrical boost converters

    Directory of Open Access Journals (Sweden)

    Eliana Isabel Arango Zuluaga

    2014-01-01

    Full Text Available The asymmetrical interleaved dual boost (AIDB is a fifth-order DC/DC converter designed to interface photovoltaic (PV panels. The AIDB produces small current harmonics to the PV panels, reducing the power losses caused by the converter operation. Moreover, the AIDB provides a large voltage conversion ratio, which is required to step-up the PV voltage to the large dc-link voltage used in grid-connected inverters. To reject irradiance and load disturbances, the AIDB must be operated in a closed-loop and a dynamic model is required. Given that the AIDB converter operates in Discontinuous Conduction Mode (DCM, classical modeling approaches based on Continuous Conduction Mode (CCM are not valid. Moreover, classical DCM modeling techniques are not suitable for the AIDB converter. Therefore, this paper develops a novel mathematical model for the AIDB converter, which is suitable for control-pur-poses. The proposed model is based on the calculation of a diode current that is typically disregarded. Moreover, because the traditional correction to the second duty cycle reported in literature is not effective, a new equation is designed. The model accuracy is contrasted with circuital simulations in time and frequency domains, obtaining satisfactory results. Finally, the usefulness of the model in control applications is illustrated with an application example.

  2. Modeling of asymmetrical boost converters

    Directory of Open Access Journals (Sweden)

    Eliana Isabel Arango Zuluaga

    2014-03-01

    Full Text Available The asymmetrical interleaved dual boost (AIDB is a fifth-order DC/DC converter designed to interface photovoltaic (PV panels. The AIDB produces small current harmonics to the PV panels, reducing the power losses caused by the converter operation. Moreover, the AIDB provides a large voltage conversion ratio, which is required to step-up the PV voltage to the large dc-link voltage used in grid-connected inverters. To reject irradiance and load disturbances, the AIDB must be operated in a closed-loop and a dynamic model is required. Given that the AIDB converter operates in Discontinuous Conduction Mode (DCM, classical modeling approaches based on Continuous Conduction Mode (CCM are not valid. Moreover, classical DCM modeling techniques are not suitable for the AIDB converter. Therefore, this paper develops a novel mathematical model for the AIDB converter, which is suitable for control-pur-poses. The proposed model is based on the calculation of a diode current that is typically disregarded. Moreover, because the traditional correction to the second duty cycle reported in literature is not effective, a new equation is designed. The model accuracy is contrasted with circuital simulations in time and frequency domains, obtaining satisfactory results. Finally, the usefulness of the model in control applications is illustrated with an application example.

  3. The Boost Converter – Revisited

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2015-12-01

    Full Text Available The dc-to-dc boost converter is a single-switch, single-inductor, switching circuit used to efficiently transform energy from one dc voltage level to a greater voltage level of the same relative polarity. For a specific resistive load range, as the duty cycle decreases, the boost converter inductor enters a discontinuous current mode of operation - the output load current having decreased to a definable level. This paper analyses the fact that a further reduction of load current, as the duty cycle decreases towards zero, will always result in the re-emergence of a continuous inductor current condition. Further, at the other load extreme, high-current, progressively for increasing load current, starting at low duty cycle conditions, the minimum inductor current always increases from a fixed normalised current level, for a specific load range. These and other hitherto unexplored boost converter properties are analysed and verified mathematically and with PSpice simulations. 

  4. Simplified design of data converters

    CERN Document Server

    Lenk, John

    1997-01-01

    Simplified Design of Data Converters shows how to design and experiment with data converters, both analog-to-digital and digital to analog. The design approach here is the same one used in all of John Lenk's best-selling books on simplified and practical design. Throughout the book, design problems start with guidelines for selecting all components on a trial-value basis, assuming a specific design goal and set of conditions. Then, using the guideline values in experimental circuits, the desired results are produced by varying the experimental component values, if needed.If you are a w

  5. An Artificial Turf-Based Surrogate Surface Collector for the Direct Measurement of Atmospheric Mercury Dry Deposition

    Directory of Open Access Journals (Sweden)

    Naima L. Hall

    2017-02-01

    Full Text Available This paper describes the development of a new artificial turf surrogate surface (ATSS sampler for use in the measurement of mercury (Hg dry deposition. In contrast to many existing surrogate surface designs, the ATSS utilizes a three-dimensional deposition surface that may more closely mimic the physical structure of many natural surfaces than traditional flat surrogate surface designs (water, filter, greased Mylar film. The ATSS has been designed to overcome several complicating factors that can impact the integrity of samples with other direct measurement approaches by providing a passive system which can be deployed for both short and extended periods of time (days to weeks, and is not contaminated by precipitation and/or invalidated by strong winds. Performance characteristics including collocated precision, in-field procedural and laboratory blanks were evaluated. The results of these performance evaluations included a mean collocated precision of 9%, low blanks (0.8 ng, high extraction efficiency (97%–103%, and a quantitative matrix spike recovery (100%.

  6. The response of earthworms (Eisenia fetida) and soil microbes to the crumb rubber material used in artificial turf fields.

    Science.gov (United States)

    Pochron, Sharon T; Fiorenza, Andrew; Sperl, Cassandra; Ledda, Brianne; Lawrence Patterson, Charles; Tucker, Clara C; Tucker, Wade; Ho, Yuwan Lisa; Panico, Nicholas

    2017-04-01

    Municipalities have been replacing grass fields with artificial turf, which uses crumb rubber infill made from recycled tires. Crumb rubber contains hydrocarbons, organic compounds, and heavy metals. Water runoff from crumb rubber fields contains heavy metals. These components can damage the environment. We contaminated topsoil with new crumb rubber and measured its impact on earthworms and soil microbes. Specifically, we compared soil microbe activity and earthworm health, survivorship, and longevity in heat and light stress under two soil regimes: clean topsoil and clean topsoil contaminated with crumb rubber. We then characterized levels of metals, nutrients, and micronutrients of both soil treatments and compared those to published New York soil background levels and to levels set by the New York State Department of Environmental Conservation (DEC) as remediation goals. We found that: 1) contaminated soil did not inhibit microbial respiration rates, 2) earthworm survivorship was not impacted by exposure to contaminated soil, 3) earthworms' ability to cope with heat and light stress remained unchanged after living in contaminated soil, but 4) earthworms living in contaminated soil gained 14% less body weight than did earthworms living in uncontaminated soil. We also found that, with the exception of zinc, heavy metals in our contaminated soil did not exceed the background levels found throughout New York State or the remediation targets set by the DEC. Published by Elsevier Ltd.

  7. Reestablishing a spawning population of lake trout in Lake Superior with fertilized eggs in artificial turf incubators

    Science.gov (United States)

    Bronte, Charles R.; Schram, Stephen T.; Selgeby, James H.; Swanson, Bruce L.

    2002-01-01

    Fertilized eggs from lake trout Salvelinus namaycush were placed in artificial turf incubators and deployed on Devils Island Shoal, Lake Superior, in an attempt to reestablish a spawning population on this once important spawning area. Efficacy was measured by the changes in catch rates, age composition, and origin of adult lake trout returning to the shoal in the fall in subsequent years. The abundance of lake trout spawners without fin clips, which implies that these fish hatched in the lake, increased throughout the sampling period, whereas the abundance of hatchery-reared fish (indicated by one or more fin clips) stocked for restoration purposes remained low. Year-class-specific stock-recruitment analysis suggested that the recruitment of unclipped spawners was related to the number of eggs planted in previous years rather than to spawning by the few adult lake trout visiting the reef. Increases in adult fish at Devils Island Shoal were independent of trends at adjacent sites, where unclipped spawner abundances remained low. Enhanced survival to hatch and apparent site imprinting of young lake trout make this technique a viable alternative to stocking fingerling and yearling lake trout to reestablish spawning populations on specific sites in the Great Lakes.

  8. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  9. A digital to analog converter

    NARCIS (Netherlands)

    Westra, Jan R.; Annema, Anne J.

    2000-01-01

    A digital to analog converter for a multibit digital input signal has a set of conversion elements for the positive signal excursions and a set of conversion elements for the negative signal excursions. In each set the conversion elements are selected according to a dynamic element matching

  10. A digital to analog converter

    NARCIS (Netherlands)

    Westra, Jan R.; Annema, Anne J.

    2006-01-01

    A digital to analog converter for a multibit digital input signal has a set of conversion elements for the positive signal excursions and a set of conversion elements for the negative signal excursions. In each set the conversion elements are selected according to a dynamic element matching

  11. XML Docbook to Mediawiki Converter

    Directory of Open Access Journals (Sweden)

    Maria Chiara Pievatolo

    2013-05-01

    Full Text Available A Perl script, based on the work of Stefano Selleri, to migrate XML-Docbook 4.X documents to Wiki markup. I added some lines to meet my need to convert my Kant translations from Docbook to MediaWiki. A sample of the output can be...

  12. Multilevel converters for power system applications

    Energy Technology Data Exchange (ETDEWEB)

    Lai, J.S.; Stovall, J.P. [Oak Ridge National Lab., TN (United States); Peng, F.Z. [Univ. of Tennessee, Knoxville, TN (United States)]|[Oak Ridge National Lab., TN (United States)

    1995-09-01

    Multilevel converters are emerging as a new breed of power converter options for power system applications. These converters are most suitable for high voltage high power applications because they connect devices in series without the need for component matching. One of the major limitations of the multilevel converters is the voltage unbalance between different levels. To avoid voltage unbalance between different levels, several techniques have been proposed for different applications. Excluding magnetic-coupled converters, this paper introduces three multilevel voltage source converters: (1) diode-clamp, (2) flying-capacitors, and (3) cascaded inverters with separate dc sources. The operation principle, features, constraints, and potential applications of these converters will be discussed.

  13. Multilevel push pull power converter

    DEFF Research Database (Denmark)

    2007-01-01

    A power converter for converting an input voltage (Vin) into an output voltage (Vout), comprising a first supply potential and a second supply potential established by the input voltage, and at least one primary winding having two terminals, a center tap arranged between the two terminals...... and connected to the first supply potential, and at least one secondary winding magnetically coupled to the primary winding for providing at least one output voltage (Vout); and a first controllable switch connected between the second supply potential and one terminal of the primary winding and a second...... controllable switch connected between the second supply potential and the other terminal of the primary winding and a third controllable switch connected between the second supply potential and the one terminal of the primary winding and a fourth controllable switch connected between the second supply...

  14. Efficiency of Capacitively Loaded Converters

    DEFF Research Database (Denmark)

    Andersen, Thomas; Huang, Lina; Andersen, Michael A. E.

    2012-01-01

    This paper explores the characteristic of capacitance versus voltage for dielectric electro active polymer (DEAP) actuator, 2kV polypropylene film capacitor as well as 3kV X7R multi layer ceramic capacitor (MLCC) at the beginning. An energy efficiency for capacitively loaded converters...... is introduced as a definition of efficiency. The calculated and measured efficiency curves for charging DEAP actuator, polypropylene film capacitor and X7R MLCC are provided and compared. The attention has to be paid for the voltage dependent capacitive load, like X7R MLCC, when evaluating the charging...... efficiency of converter. Based on the capacitancevoltage curve, the correct capacitance should be chosen when calculating the stored energy; otherwise misleading optimistic efficiency can always be obtained. Actually, when DEAP actuator is not available at the early developing stage, the voltage independent...

  15. Radiated EMI from power converters

    Directory of Open Access Journals (Sweden)

    Arnautovski-Toševa Vesna

    2005-01-01

    Full Text Available With the continuous increase of switching frequency together with the ongoing trend to higher complexity and functionality, power converters as a part of electronic systems have raised more and more electromagnetic energy pollution to the local system environment. In the same time, stringent demands are imposed on the designers of new circuits that electromagnetic interference (EMI has to be suppressed at its source before it is allowed to propagate into other circuits and systems. In this paper, the authors present a full-wave numerical method for calculation and simulation of electromagnetic field radiated by power converter circuitry. The main objective is to analyze the layout geometry in order to obtain competitive PCB layout that will enable suitably attenuated level of the radiated electric field to safe level. By this it would be possible to ensure reliable operation of the sensitive electronic components in the proximity.

  16. A digital to analog converter

    OpenAIRE

    Westra, Jan R.; Annema, Anne J.

    2000-01-01

    A digital to analog converter for a multibit digital input signal has a set of conversion elements for the positive signal excursions and a set of conversion elements for the negative signal excursions. In each set the conversion elements are selected according to a dynamic element matching algorithm. To improve the mismatch-noise shaping of these algorithms, excess conversion elements may be additionally selected.

  17. Development of a Compact Matrix Converter

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2009-01-01

    Full Text Available This paper deals with the development of a matrix converter. Matrix converters belong to the category of direct frequency converters. A converter does not contain DC-link and the output voltage is provided by direct switching of voltage from the input phases. This is enabled by 9 bidirectional switches, which are provided by anti-serial connection of 18 IGBT transistors. The absence of a DC-link is great advantage of the matrix converter, but it also increases the requirements on the converter control. For this reason a new prototype of a matrix converter is being developed with sophisticated modern components (FPGA, Power PC equipped in the control part of the converter. The converter will be used for testing new control algorithms and commutation methods. 

  18. Computerized simulation of converter process

    Energy Technology Data Exchange (ETDEWEB)

    Jalkanen, H.; Suomi, M.L.; Wallgren, M. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Metallurgy

    1996-12-31

    Converter process is essentially an oxidising refining process aiming in addition to (1) the primary refining action, decarburisation of high carbon iron melt, also to (2) maximal elimination of impurity elements, especially silicon, phosphorus and sulphur, (3) melting of substantial amounts of scrap using the extra heat released in oxidation reactions and (4) to exact final steel temperature control, optimal for further treatments. `Quantitative modelling of such a complex non-stationary chemical process as oxygen converting necessitates extensive formulation of chemical and thermal evolution of the process in connection with the technological properties of the reactor and the process control measures. A comprehensive converter simulation program like CONSIM-3. 1 and its preceding versions that is based on the theoretical and practical knowledge on the process can be used for (1) educating specialists and smelter personnel, (2) planning of the blowing programs, (3) developing and testing of process control systems and after some elaboration and restructuring (4) it can be integrated to static or dynamic process control systems. (orig.) SULA 2 Research Programme; 10 refs.

  19. High efficiency thermionic converter studies

    Science.gov (United States)

    Huffman, F. N.; Sommer, A. H.; Balestra, C. L.; Briere, D. P.; Oettinger, P. E.

    1976-01-01

    The objective is to improve thermionic converter performance by means of reduced interelectrode losses, greater emitter capabilities, and lower collector work functions until the converter performance level is suitable for out-of-core space reactors and radioisotope generators. Electrode screening experiments have identified several promising collector materials. Back emission work function measurements of a ZnO collector in a thermionic diode have given values less than 1.3 eV. Diode tests were conducted over the range of temperatures of interest for space power applications. Enhanced mode converter experiments have included triodes operated in both the surface ionization and plasmatron modes. Pulsed triodes were studied as a function of pulse length, pulse potential, inert gas fill pressure, cesium pressure, spacing, emitter temperature and collector temperature. Current amplifications (i.e., mean output current/mean grid current) of several hundred were observed up to output current densities of one amp/sq cm. These data correspond to an equivalent arc drop less than 0.1 eV.

  20. Simulation Results of Double Forward Converter

    Directory of Open Access Journals (Sweden)

    P. Vijaya KUMAR

    2009-12-01

    Full Text Available This work aims to find a better forward converter for DC to DC conversion.Simulation of double forward converter in SMPS system is discussed in this paper. Aforward converter with RCD snubber to synchronous rectifier and/or to current doubleris also discussed. The evolution of the forward converter is first reviewed in a tutorialfashion. Performance parameters are discussed including operating principle, voltageconversion ratio, efficiency, device stress, small-signal dynamics, noise and EMI. Itscircuit operation and its performance characteristics of the forward converter with RCDsnubber and double forward converter are described and the simulation results arepresented.

  1. Analysis and comparison of modern methods of turf irrigation, verifying the capability of existing information systems through the use of numerical modeling

    Science.gov (United States)

    Deangelis, Maria Laura; Facoetti, Nicola

    2016-04-01

    The automated irrigation of parks and gardens in public areas has become more and more a common practice due to the many benefits it brings in terms of improving the quality of urban green areas. Since this practice requires significant volumes of water, and this becomes increasingly scarce and expensive, it is necessary that the design criteria and use management aim at maximizing the irrigation efficiency. There are conflicting relationship and competition between trees and turf for several reasons. On one hand the different irrigation needs can cause excess water in the root zones of the trees, on the other hand the surface roots of trees and the shade created from the leaves by the dripline (projection line of the canopy) determine an unfavorable area to the growth of the turf because of light factor. It follows that for an optimal design of an irrigation system is necessary to separate the turf areas from trees, with the disadvantage of considerably complicate the geometries of the sprinklers. Each tree or group of trees need to be associated to a not irrigated area. This problem seems not to have a specifically bibliographical evidence, although there are operating standards primarily used to define buffer zones for trees from constructions (British Standard 5837:2005). Ideally, a high number of sprinklers is required to follow the shape of the areas perfectly. Hence, an additional step is necessary to simplify these geometries, identifying a correct scheme for the sprinkler spacing. Such a sequence of geometric operations has been tested on the "Indro Montanelli" park in Milan, obtaining a reduction of the irrigated area of 47% and a water saving of around 30%. We intend to continue the research applying the model to other parks, verifying its applicability in different situations.

  2. Electromechanical converters for electric vehicles

    Science.gov (United States)

    Ambros, T.; Burduniuc, M.; Deaconu, S. I.; Rujanschi, N.

    2018-01-01

    The paper presents the analysis of various constructive schemes of synchronous electromechanical converters with permanent magnets fixed on the rotor and asynchronous with the short-circuit rotor. Various electrical stator winding schemes have also been compared, demonstrating the efficiency of copper utilization in toroidal windings. The electromagnetic calculus of the axial machine has particularities compared to the cylindrical machine, in the paper is presented the method of correlating the geometry of the cylindrical and axial machines. In this case the method and recommendations used in the design of such machines may be used.

  3. OAM mode converter in twisted fibers

    DEFF Research Database (Denmark)

    Usuga Castaneda, Mario A.; Beltran-Mejia, Felipe; Cordeiro, Cristiano

    2014-01-01

    We analyze the case of an OAM mode converter based on a twisted fiber, through finite element simulations where we exploit an equivalence between geometric and material transformations. The obtained converter has potential applications in MDM. © 2014 OSA.......We analyze the case of an OAM mode converter based on a twisted fiber, through finite element simulations where we exploit an equivalence between geometric and material transformations. The obtained converter has potential applications in MDM. © 2014 OSA....

  4. 12 CFR 1.6 - Convertible securities.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Convertible securities. 1.6 Section 1.6 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY INVESTMENT SECURITIES § 1.6 Convertible securities. A national bank may not purchase securities convertible into stock at the option of...

  5. Convertible Subspaces of Hessenberg-Type Matrices

    Directory of Open Access Journals (Sweden)

    Henrique F. da Cruz

    2017-12-01

    Full Text Available We describe subspaces of generalized Hessenberg matrices where the determinant is convertible into the permanent by affixing ± signs. An explicit characterization of convertible Hessenberg-type matrices is presented. We conclude that convertible matrices with the maximum number of nonzero entries can be reduced to a basic set.

  6. Ecologically Optimal Solution of Power Semiconductors Converters

    Directory of Open Access Journals (Sweden)

    Pavol Spanik

    2003-01-01

    Full Text Available One of the relevant scientific programs of Department of Power Electrical Systems is research of ecologically optimal topologies main circuits of power converters. This paper presents some methods how to reduce unfavourable influences of power converters on the grid. The achieved results were applieed in praxis, especially in the power converters produced by Electrotechnical Research and Projecting Institute in Nova Dubnica.

  7. A novel converter topology for TEM applications

    Indian Academy of Sciences (India)

    and energy levels of the TEM system, require special type of excitation technique. Power converters for ... This paper proposes a novel converter topology to meet these excitation current require- ments. A novel ... The converter control system is given a square wave current reference of required amplitude,. ON duration TS ...

  8. Hybrid thermionic-photovoltaic converter

    Science.gov (United States)

    Datas, A.

    2016-04-01

    A conceptual device for the direct conversion of heat into electricity is presented. This concept hybridizes thermionic (TI) and thermophotovoltaic (TPV) energy conversion in a single thermionic-photovoltaic (TIPV) solid-state device. This device transforms into electricity both the electron and photon fluxes emitted by an incandescent surface. This letter presents an idealized analysis of this device in order to determine its theoretical potential. According to this analysis, the key advantage of this converter, with respect to either TPV or TI, is the higher power density in an extended temperature range. For low temperatures, TIPV performs like TPV due to the negligible electron flux. On the contrary, for high temperatures, TIPV performs like TI due to the great enhancement of the electron flux, which overshadows the photon flux contribution. At the intermediate temperatures, ˜1650 K in the case of this particular study, I show that the power density potential of TIPV converter is twice as great as that of TPV and TI. The greatest impact concerns applications in which the temperature varies in a relatively wide range, for which averaged power density enhancement above 500% is attainable.

  9. Hybrid thermionic-photovoltaic converter

    Energy Technology Data Exchange (ETDEWEB)

    Datas, A. [Instituto de Energía Solar, Universidad Politécnica de Madrid, 28040 Madrid (Spain)

    2016-04-04

    A conceptual device for the direct conversion of heat into electricity is presented. This concept hybridizes thermionic (TI) and thermophotovoltaic (TPV) energy conversion in a single thermionic-photovoltaic (TIPV) solid-state device. This device transforms into electricity both the electron and photon fluxes emitted by an incandescent surface. This letter presents an idealized analysis of this device in order to determine its theoretical potential. According to this analysis, the key advantage of this converter, with respect to either TPV or TI, is the higher power density in an extended temperature range. For low temperatures, TIPV performs like TPV due to the negligible electron flux. On the contrary, for high temperatures, TIPV performs like TI due to the great enhancement of the electron flux, which overshadows the photon flux contribution. At the intermediate temperatures, ∼1650 K in the case of this particular study, I show that the power density potential of TIPV converter is twice as great as that of TPV and TI. The greatest impact concerns applications in which the temperature varies in a relatively wide range, for which averaged power density enhancement above 500% is attainable.

  10. Small-sided football games on sand are more physical-demanding but less technical-specific compared to artificial turf.

    Science.gov (United States)

    Rago, Vincenzo; Rebelo, António N; Pizzuto, Federico; Barreira, Daniel

    2016-09-15

    The use of sand has been suggested as fitness-enhancing surface in field-based team sports. However, concerns have arisen in regard whether physical responses associated to sand training are sport-specific. We compared physical and technical demands during small-sided football games (4v4 + goalkeeper; SSGs) played on artificial turf and on sand. Movement patterns, rating of perceived exertion (RPE) and technical parameters were obtained from eight adult male footballers (20.1±1.0 years, 176±4 cm and 70.1±2.0 kg) using Global Positioning Systems, Visual Analogue Scale questionnaires and Notational analysis respectively. High-intensity actions (high intensity running, high intensity activities), low changes of speed, as well as peak and average speed were higher on artificial turf (ptraining, when the training goal is to tax lower-limb muscle strength or to require high-ball situations. Nonetheless, sand training is not appropriate when the achievement of maximal speed is desired. Further research should clarify the suitability of sand training within football conditioning programmes.

  11. Converting pest insects into food

    DEFF Research Database (Denmark)

    Offenberg, Hans Joachim; Wiwatwittaya, Decha

    2010-01-01

    Canopy dwelling weaver ants (Oecophylla spp.) are used to control a variety of pests in a number of tropical tree crops. What is less familiar is the existence of commercial markets where these ants and their brood are sold for (i) human consumption, (ii) pet food or (iii) traditional medicine...... on management, 32-115 kg ant brood (mainly new queens) was harvested per ha per year without detrimental effect on colony survival and worker ant densities. This suggest that ant biocontrol and ant harvest can be sustainable integrated in plantations and double benefits derived. As ant production is fuelled...... by pest insects, problematic pests are converted into food and additional earnings. To assess the profitability of providing additional food for the ants, O. smaragdina food conversion efficiency (ECI) was estimated in the laboratory. This estimate suggests the feeding of weaver ants in ant farms...

  12. High-Performance Data Converters

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    in a standard CMOS technology, they can be designed to yield 100 dB performance at 10 times oversampling. The proposed scaled-element mismatch-shaping D/A converters are well suited for use as the feedback stage in oversampled delta-sigma quantizers. It is, however, not easy to make full use of their potential...... this problem. This way, the delta-sigma quantizer's feedback signal is obtained by a multiple-stage quantization, where the loop quantizer (low-resolution and minimum-delay) implements only the last-stage quantization. Hence, high-speed, high-resolutiondelta-sigma quantization is feasible without using complex...... circuitry. An improved version of the MASH topology is also proposed. A delta-sigma quantizer is used to quantize the input signal into an oversampled digital representation of low-to-moderate resolution. The delta-sigma quantizer'struncation error is estimated either directly, or as the first...

  13. Reliability of Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon

    There are many different working principles for wave energy converters (WECs) which are used to produce electricity from waves. In order for WECs to become successful and more competitive to other renewable electricity sources, the consideration of the structural reliability of WECs is essential...... WEPTOS. Calibration of safety factors are performed for welded structures at theWavestar device including different control systems for harvesting energy from waves. In addition, a case study of different O&M strategies for WECs is discussed, and an example of reliability-based structural optimization....... Structural reliability considerations and optimizations impact operation and maintenance (O&M) costs as well as the initial investment costs. Furthermore, there is a control system for WEC applications which defines the harvested energy but also the loads onto the structure. Therefore, extreme loads but also...

  14. Reliability of Wave Energy Converters

    DEFF Research Database (Denmark)

    Ambühl, Simon

    There are many different working principles for wave energy converters (WECs) which are used to produce electricity from waves. In order for WECs tobecome successful and more competitive to other renewable electricity sources,the consideration of the structural reliability of WECs is essential...... for welded structures at the Wavestar device includingdifferent control systems for harvesting energy from waves. In addition, a casestudy of different O&M strategies for WECs is discussed, and an example ofreliability-based structural optimization of the Wavestar foundation ispresented. The work performed.......Structural reliability considerations and optimizations impact operation andmaintenance (O&M) costs as well as the initial investment costs.Furthermore, there is a control system for WEC applications which defines theharvested energy but also the loads onto the structure. Therefore, extremeloads but also fatigue loads...

  15. The SSG Wave Energy Converter

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Margheritini, Lucia; Kofoed, Jens Peter

    2012-01-01

    The Sea-wave Slot-cone Generator concept (SSG) is a Wave Energy Converter based on the wave overtopping principle utilizing several reservoirs placed on top of each other, in which the energy of the incoming wave will be stored as potential energy. The water captured in the reservoirs will then run...... through turbines for electricity production. The system utilizes a wide spectrum of different wave conditions by means of multiple reservoirs, located at different levels above the still water level. Thereby, it obtains a high overall efficiency and it can be suitable for shoreline and breakwater...... at the Svaaheia site (Norway), Port of Hanstholm (Denmark) and Port of Garibaldi (Oregon, USA). In the last-mentioned two projects, the Sea-wave Slot-cone Generator technology is integrated into outer harbor breakwater and jetty reconstruction projects. Comprehensive studies have been performed in the last years...

  16. Three-phase AC-AC power converters based on matrix converter topology matrix-reactance frequency converters concept

    CERN Document Server

    Szczesniak, Pawel

    2013-01-01

    AC voltage frequency changes is one of the most important functions of solid state power converters. The most desirable features in frequency converters are the ability to generate load voltages with arbitrary amplitude and frequency, sinusoidal currents and voltages waveforms; the possibility of providing unity power factor for any load; and, finally, a simple and compact power circuit. Over the past decades, a number of different frequency converter topologies have appeared in the literature, but only the converters with either a voltage or current DC link are commonly used in industrial app

  17. Multilevel converters for 10 MW Wind Turbines

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2011-01-01

    Several promising multi-level converter configurations for 10 MW Wind Turbines both with direct drive and one-stage gear box drive using Permanent Magnet Synchronous Generator (PMSG) are proposed, designed and compared. Reliability is a crucial indicator for large scale wind power converters......, therefore the evaluations are mainly focused on the power device thermal performances, which are closely related to the life time and cost of the converter. Simulation results of different converter candidates regarding the loss and junction temperature are presented and analyzed. It is concluded...... that the three-level and five-level H-bridge converter topologies both have potential to achieve improved thermal performances compared to the three-level Neutral-Point-Clamped converter topology in the wind power application....

  18. Gadolinium sheet converter for neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lima, C.T.S. [Laboratorio de Neutrongrafia em Tempo Real (LNRTR/PEN/COPPE), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil); Crispim, V.R. [Laboratorio de Neutrongrafia em Tempo Real (LNRTR/PEN/COPPE), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil); PEN/COPPE-DNC/Escola Politecnica CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil)], E-mail: verginia@con.ufrj.br; Santos, W.M.S. [Laboratorio de Colisao Atomica e Molecular (LACAM/IF), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68528, 21941-972 Rio de Janeiro, RJ (Brazil)

    2007-12-15

    This work describes a methodology developed for the confection of gadolinium sheet converter for neutron radiography using the gadolinium chloride (GdCl{sub 3}) as material converter. Though manufactured at a relatively low cost, they are as good as the sheet converter on the market. Here, we present neutron radiography of the penetrameter, the edge spread function, the modulation transfer function and characteristic curves for each set sheet-AA400 Kodak film.

  19. Ocean floor mounting of wave energy converters

    Science.gov (United States)

    Siegel, Stefan G

    2015-01-20

    A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.

  20. Commutation Processes in Multiresonant ZVS Bridge Converter

    Directory of Open Access Journals (Sweden)

    Miroslaw Luft

    2008-01-01

    Full Text Available The analysis of the multiresonant ZVS DC/DC bridge converter is presented. The control system of the converter is basedon the method of frequency control at the constant time of transistor turn-off with a phase shift. The operation of the circuit is givenand the operating range of the converter is defined where ZVS switching operation is assured. Control characteristics are given andthe converter’s efficiency is defined. The circuit’s operation is analysed on the basis of results of the converter simulation tests using Simplorer programme.

  1. Conducted Emission Evaluation for Direct Matrix Converters

    Science.gov (United States)

    Nothofer, A.; Tarisciotti, L.; Greedy, S.; Empringham, L.; De Lillo, L.; Degano, M.

    2016-05-01

    Matrix converters have been recently proposed as an alternative solution to the standard back-to-back converter in aerospace applications. However, Electromagnetic Interference (EMI), in particular, conducted emissions represent a critical aspect for this converter family. Direct Matrix Converter (DMC) are usually modelled only at the normal operating frequency, but for the research presented in this paper, the model is modified in order to include a detailed high frequency description, which is of interest for conducted emission studies.This paper analyzes the performance of DMC, when different control and modulation techniques are used. Experimental results are shown to validate the simulation models.

  2. Soil Carbon and Carbon/Nitrogen Ratio Change under Tree Canopy, Tall Grass, and Turf Grass Areas of Urban Green Space.

    Science.gov (United States)

    Livesley, S J; Ossola, A; Threlfall, C G; Hahs, A K; Williams, N S G

    2016-01-01

    Soils in urban green spaces are an important carbon (C) store, but urban soils with a high carbon to nitrogen (C/N) ratio can also buffer N eutrophication from fertilizer use or atmospheric deposition. The influence of vegetation management practices on soil C cycling and C/N ratios in urban green spaces is largely unknown. In 2013, we collected replicate ( = 3) soil samples from tree canopy, tall grass, and short turf grass areas ( = 3) at four random plot locations ( = 4) established in 13 golf courses ( = 13). At each sample point, soil was separated into 0- to 0.1-, 0.1- to 0.2-, and 0.2- to 0.3-m depths (total = 1404). Linear mixed models investigated the relationships between soil properties, vegetation attributes, and green space age. Tree canopy soil was less compacted (1.07 g cm) than grassy areas (1.32 g cm). Similarly, tree canopy soil had mean C/N ratios of 17.2, as compared with between 14.2 and 15.3 in grassy areas. Soil properties in tree canopy areas were best explained by tree basal area and understory vegetation volume. Soil C/N increased with increasing understory vegetation, and the difference in soil C/N between tree canopy and short turf grass areas increased over time. The soil properties in tree canopy areas of urban green space mean they can increasingly buffer the localized use of N fertilizers and atmospheric N deposition. Managers of urban green spaces concerned about N pollution of groundwater and waterways could consider planting trees in suitable topographic locations and promoting understory vegetation and surface litter accumulation. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  3. Modeling and Simulation of Matrix Converter

    DEFF Research Database (Denmark)

    Liu, Fu-rong; Klumpner, Christian; Blaabjerg, Frede

    2005-01-01

    This paper discusses the modeling and simulation of matrix converter. Two models of matrix converter are presented: one is based on indirect space vector modulation and the other is based on power balance equation. The basis of these two models is• given and the process on modeling is introduced...

  4. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    The main aims of power electronic converter systems (PECS) are to control, convert, and condition electrical power flow from one form to another through the use of solid-state electronics. This book outlines current research into the scientific modeling, experimentation, and remedial measures for...

  5. Time-Interleaved Analog to Digital Converters

    NARCIS (Netherlands)

    Louwsma, S.M.; van Tuijl, Adrianus Johannes Maria; Nauta, Bram

    2010-01-01

    This book describes the research carried out by our PhD student Simon Louwsma at the University of Twente, The Netherlands in the field of high-speed Analogto- Digital (AD) converters. AD converters are crucial circuits for modern systems where information is stored or processed in digital form. Due

  6. Synchronous Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede; Bose, Bimal K.

    2002-01-01

    for each module and the composed voltage at the output of the converter. Multilevel output voltage of the converter has quarter-wave symmetry during the whole range including the zone of overmodulation. Both continuous and discontinuous versions of synchronous PWM, based on vector approach...

  7. High Precision Current Measurement for Power Converters

    CERN Document Server

    Cerqueira Bastos, M

    2015-01-01

    The accurate measurement of power converter currents is essential to controlling and delivering stable and repeatable currents to magnets in particle accelerators. This paper reviews the most commonly used devices for the measurement of power converter currents and discusses test and calibration methods.

  8. RF digital-to-analog converter

    Science.gov (United States)

    Conway, P.H.; Yu, D.U.L.

    1995-02-28

    A digital-to-analog converter is disclosed for producing an RF output signal proportional to a digital input word of N bits from an RF reference input, N being an integer greater or equal to 2. The converter comprises a plurality of power splitters, power combiners and a plurality of mixers or RF switches connected in a predetermined configuration. 18 figs.

  9. Modelling and Control of Grid converter

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede; Iov, Florin

    The present report describes the work done in the Phase 1a during the research project "Modelling and Control of Grid Converter". The developed models for the plant and different control strategies for the grid converter are presented in detail. Simulation results under different operating...

  10. Modelling and Control of Grid converter

    DEFF Research Database (Denmark)

    Iov, Florin; Teodorescu, Remus; Blaabjerg, Frede

    The present report describes the work done in the Phase 1b during the research project "Modelling and Control of Grid Converter". The models used in simulations are presented in detail. Two control strategies for the grid converter are considered for investigations, namely the Adaptive Band...

  11. Present trends in HVDC converter station design

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, Lennart; Asplund, Gunnar; Bjorklund, Hans; Flisberg, Gunnar [ABB Power Systems AB, Ludvika (Sweden)

    1994-12-31

    HVDC converter station technology has developed rapidly to satisfy increasing requirements during past 10 - 15 years, but there has not been any dramatic changes since thyristor valves were introduced in the mid 70s. This paper describes some recent and expected future developments, that will substantiality change and simplify future converter stations. (author) 4 refs., 7 figs.

  12. Step-Up DC-DC converters

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam P.; Gorji, Saman A.

    2017-01-01

    on the general law and framework of the development of next-generation step-up dc-dc converters, this paper aims to comprehensively review and classify various step-up dc-dc converters based on their characteristics and voltage-boosting techniques. In addition, the advantages and disadvantages of these voltage...

  13. Transformer Isolated Buck-Boost Converters

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2016-12-01

    Full Text Available Of the single-switch dc-to-dc converters, those with the buck-boost voltage transfer function offer most potential for transformer coupling, hence isolation, at the kilowatt level. This paper highlights the limitations of the traditional magnetic coupled, buck-boost topology. Then four split-capacitor transformer-coupled topologies (specifically the Cuk, sepic, zeta, and a new, converters with a common ac equivalent circuit are explored, that do not temporarily store core magnetic energy as does the traditional isolated buck-boost converter nor have a core dc magnetizing current bias, as with the sepic and zeta transformer coupled topologies. Core dc bias capacitive voltage compensation is a practical design constraint in three of the four topologies, while all four must cater for stray and leakage inductance effects. Simulations and experimental results for the new converter at 408W support the transformer-coupled, single-switch dc-to-dc converter concepts investigated.

  14. Modelling, analyses and design of switching converters

    Science.gov (United States)

    Cuk, S. M.; Middlebrook, R. D.

    1978-01-01

    A state-space averaging method for modelling switching dc-to-dc converters for both continuous and discontinuous conduction mode is developed. In each case the starting point is the unified state-space representation, and the end result is a complete linear circuit model, for each conduction mode, which correctly represents all essential features, namely, the input, output, and transfer properties (static dc as well as dynamic ac small-signal). While the method is generally applicable to any switching converter, it is extensively illustrated for the three common power stages (buck, boost, and buck-boost). The results for these converters are then easily tabulated owing to the fixed equivalent circuit topology of their canonical circuit model. The insights that emerge from the general state-space modelling approach lead to the design of new converter topologies through the study of generic properties of the cascade connection of basic buck and boost converters.

  15. Periodic Control of Power Electronic Converters

    DEFF Research Database (Denmark)

    Zhou, Keliang; Danwei, Wang; Yang, Yongheng

    Advanced power electronic converters convert, control and condition electricity. Power converters require control strategies for periodic signal compensation to assure good power quality and stable power system operation. This comprehensive text presents the most recent internal model principle...... based periodic control technology, which offers the perfect periodic control solution for power electronic conversion. It also provides complete analysis and synthesis methods for periodic control systems, and plenty of practical examples to demonstrate the validity of proposed periodic control...... technology for power converters. It proposes a unified framework for housing periodic control schemes for power converters, and provides a general proportional-integral-derivative control solution to periodic signal compensation in extensive engineering applications. Periodic Control of Power Electronic...

  16. A review of Indirect Matrix Converter Topologies

    Directory of Open Access Journals (Sweden)

    Salem Rahmani

    2015-08-01

    Full Text Available Abstract—Matrix Converter (MC is a modern direct AC/AC electrical power converter without dc-link capacitor. MC is operated in four quadrant, assuring a control of the output voltage, amplitude and frequency. The matrix converter has recently attracted significant attention among researchers and it has become increasing attractive for applications of wind energy conversion, military power supplies, induction motor drives, etc. Recently, different MC topologies have been proposed and developed which have their own advantages and disadvantages. Matrix converter can be classified as direct and indirect structures. The direct one has been elaborated in previous work. In this paper the indirect MCs are reviewed. Different characteristics of the indirect MC topologies are mentioned to show the strengths and weaknesses of such converter topologies.

  17. Switched Mode Four-Quadrant Converters

    CERN Document Server

    Thurel, Y

    2015-01-01

    This paper was originally presented at CAS-2004, and was slightly modified for CAS-2014. It presents a review of the key parameters that impact the design choices for a true four-quadrant power converter, in the range 1-10 kW, mainly based on switching mode converter topology. This paper will first describe the state-of-the-art for this power converter family, giving the drawbacks and advantages of different possible solutions. It will also present practical results obtained from the CERN-designed converter. It will finally give some important tips regarding critical phases like test one, when conducting a project dealing with this type of power converter.

  18. single-phase dc phase dc-ac boost converter ac boost converter

    African Journals Online (AJOL)

    User

    This paper describes a new power conversion circuit dc-dc boost converter. It boost converter. It boost converter. It comprises an H comprises an H. Change of load .... A full-wave rectified signal is used to produce an AC reference voltage v* o. The outer voltage loop generates the reference current command i* f. A common.

  19. Electromagnetic Compatibility of Matrix Converter System

    Directory of Open Access Journals (Sweden)

    S. Fligl

    2006-12-01

    Full Text Available The presented paper deals with matrix converters pulse width modulation strategies design with emphasis on the electromagnetic compatibility. Matrix converters provide an all-silicon solution to the problem of converting AC power from one frequency to another, offering almost all the features required of an ideal static frequency changer. They possess many advantages compared to the conventional voltage or current source inverters. A matrix converter does not require energy storage components as a bulky capacitor or an inductance in the DC-link, and enables the bi-directional power flow between the power supply and load. The most of the contemporary modulation strategies are able to provide practically sinusoidal waveforms of the input and output currents with negligible low order harmonics, and to control the input displacement factor. The perspective of matrix converters regarding EMC in comparison with other types of converters is brightly evident because it is no need to use any equipment for power factor correction and current and voltage harmonics reduction. Such converter with proper control is properly compatible both with the supply mains and with the supplied load. A special digital control system was developed for the realized experimental test bed which makes it possible to achieve greater throughput of the digital control system and its variability.

  20. Underwater noise from a wave energy converter

    DEFF Research Database (Denmark)

    Tougaard, Jakob

    A recent addition to the anthropogenic sources of underwater noise is offshore wave energy converters. Underwater noise was recorded from the Wavestar wave energy converter located at Hastholm, Denmark (57°7.73´N, 8°37.23´E). The Wavestar is a full-scale test and demonstration converter...... in full operation and start and stop of the converter. Median broad band (10 Hz – 20 kHz) sound pressure level (Leq) was 123 dB re. 1 Pa, irrespective of status of the wave energy converter (stopped, running or starting/stopping). The most pronounced peak in the third-octave spectrum was in the 160 Hz...... significant noise above ambient could be detected above the 250 Hz band. The absolute increase in noise above ambient was very small. L50 third-octave levels in the four bands with the converter running were thus only 1-2 dB above ambient L50 levels. The noise recorded 25 m from the wave energy converter...

  1. Selective harmonic control for power converters

    DEFF Research Database (Denmark)

    Zhou, Keliang; Yang, Yongheng; Blaabjerg, Frede

    2014-01-01

    This paper proposes an Internal Model Principle (IMP) based Selective Harmonic Controller (SHC) for power converters. The proposed SHC offers an optimal control solution for power converters to mitigate power harmonics. It makes a good trade-off among cost, complexity and performance. It has high...... accuracy and fast transient response, and it is cost-effective, easy for real-time implementation, and compatible for design rules-of-thumb. An application on a three-phase PWM converter has confirmed the effectiveness of the proposed control scheme in terms of harmonic mitigation....

  2. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    for advancing the reliability, availability, system robustness, and maintainability of PECS at different levels of complexity. Drawing on the experience of an international team of experts, this book explores the reliability of PECS covering topics including an introduction to reliability engineering in power......-tolerant adjustable speed drive systems; mission profile oriented reliability design in wind turbine and photovoltaic systems; reliability of power conversion systems in photovoltaic applications; power supplies for computers; and high-power converters. Reliability of Power Electronic Converter Systems is essential...... reading for researchers, professionals and students working with power electronics and their applications, particularly those specializing in the development and application of power electronic converters and systems....

  3. A Discrete Modeling Approach for Buck Converter

    Science.gov (United States)

    Zhaoxia, Leng; Qingfeng, Liu; Jinkun, Sun; Huamin, Wang

    In this paper, a discrete modeling approach for Buck converters based on continuous condition mode (CCM) and discontinuous condition mode (DCM) was presented. The unified coefficient matrixes of discrete model were described by building a mathematical function and the calculation methods of the parameters in coefficient matrixes were given. The working states of Buck converter on various work conditions were described adopting one discrete equation. The validity of the proposed modeling approach was proved by contrasting the output of discrete model with the operation result of Buck converter system in Simulink.

  4. High-power converters and AC drives

    CERN Document Server

    Wu, Bin

    2017-01-01

    This new edition reflects the recent technological advancements in the MV drive industry, such as advanced multilevel converters and drive configurations. It includes three new chapters, Control of Synchronous Motor Drives, Transformerless MV Drives, and Matrix Converter Fed Drives. In addition, there are extensively revised chapters on Multilevel Voltage Source Inverters and Voltage Source Inverter-Fed Drives. This book includes a systematic analysis on a variety of high-power multilevel converters, illustrates important concepts with simulations and experiments, introduces various megawatt drives produced by world leading drive manufacturers, and addresses practical problems and their mitigations methods.

  5. Pseudolog Digital-to-Analog Converter

    Science.gov (United States)

    Gooder, S. T.

    1986-01-01

    Sensitivity decreases by 10 at beginning of each input decade. Method conceived to convert binary-coded data to suitable linear form for stripchart recording. Strip-chart recordings obtained from typical pressure readings in a vacuum system during pumpdown. In reading curve, BCD digital vacuum-gage output processed by analog-to-digital converter in such way that only reading digits (but not range) appear in output. In range and reading, range also converted to analog and placed as most significant digit.

  6. Programmable Analog-To-Digital Converter

    Science.gov (United States)

    Kist, Edward H., Jr.

    1993-01-01

    High-speed analog-to-digital converter with programmable voltage steps that can be changed during operation. Allows concentration of converter resolution over specific portion of waveform. Particularly useful in digitizing wind-shear radar and lidar return signals, in digital oscilloscopes, and other applications in which desirable to increase digital resolution over specific area of waveform while accepting lower resolution over rest of waveform. Effective increase in dynamic range achieved without increase in number of analog-to-digital converter bits. Enabling faster analog-to-digital conversion.

  7. Heatsink Design of High Power Converter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Ki [Chungang University (Korea)

    1999-04-01

    Various ways of designing heat sink are available for commercial high power converters and among them, the method of air cooling is the most popular and practical method than any other ones. In this paper, a practical method of cooling high power converter, which includes a method of reducing noise and vibration caused by the fan and a method of estimating the gap and contact resistances existing between the thyristor and heat sink, is presented. Finally, the heat transfer analysis and implementation methods of heat sink for high power converter is presented. (author). 14 refs., 11 figs., 3 tabs.

  8. Power Electronics Converters for Wind Turbine Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Liserre, Marco; Ma, Ke

    2012-01-01

    The steady growth of installed wind power together with the upscaling of the single wind turbine power capability has pushed the research and development of power converters toward full-scale power conversion, lowered cost pr kW, increased power density, and also the need for higher reliability......, in the latter case with attention to series connection and parallel connection either electrical or magnetic ones (multiphase/windings machines/transformers). It is concluded that as the power level increases in wind turbines, medium-voltage power converters will be a dominant power converter configuration...

  9. multilevel buck converter for automotive electrical load

    African Journals Online (AJOL)

    user

    MULTILEVEL BUCK CONVERTER FOR AUTOMOTIVE ELECTRICAL LOAD. E. T. Yabefa1,* and D. Ebregbe2. 1ELECTRICAL DEPARTMENT, BAYELSA STATE COLLEGE OF ARTS & SCIENCE (BYCAS) YENAGOA, BAYELSA STATE NIGERIA. 2ELECTRICAL ENGINEERING DEPARTMENT, NIGER DELTA UNIVERSITY, ...

  10. Reliability of power electronic converter systems

    CERN Document Server

    Chung, Henry Shu-hung; Blaabjerg, Frede; Pecht, Michael

    2016-01-01

    This book outlines current research into the scientific modeling, experimentation, and remedial measures for advancing the reliability, availability, system robustness, and maintainability of Power Electronic Converter Systems (PECS) at different levels of complexity.

  11. State estimation for wave energy converters

    Energy Technology Data Exchange (ETDEWEB)

    Bacelli, Giorgio; Coe, Ryan Geoffrey

    2017-04-01

    This report gives a brief discussion and examples on the topic of state estimation for wave energy converters (WECs). These methods are intended for use to enable real-time closed loop control of WECs.

  12. Load balancing multimodule switching power converters

    Science.gov (United States)

    Mclyman, W. T.; Wester, G. W.

    1979-01-01

    Regulating system individually adjusts duty cycles of modules so that all share load equally, thus, protects individual modules and their components from overload and increases reliability and life expectancy. Converters are alternative to high-power, single unit systems.

  13. A three-port direct current converter

    DEFF Research Database (Denmark)

    2016-01-01

    The three-port direct current converter comprising: at least one input direct current source; at least one storage battery; a primary side circuit; a secondary side circuit; a first single magnetic component shared by the primary side circuit and the secondary side circuit, wherein the primary side...... circuit comprises a connection between the at least one input direct current source and the at least one storage battery, the primary side circuit configured for operating as a buck converter; a second magnetic component serially coupled to the first single magnetic component, wherein the first and second...... magnetic components are configured to perform a voltage step-up, wherein the secondary side circuit comprises a connection between the at least one storage battery and at least one load, the secondary side configured for operating as a tapped boost converter; wherein the three-port direct current converter...

  14. Catalytic converters as a source of platinum

    Directory of Open Access Journals (Sweden)

    A. Fornalczyk

    2011-10-01

    Full Text Available The increase of Platinum Group Metals demand in automotive industry is connected with growing amount of cars equipped with the catalytic converters. The paper presents the review of available technologies during recycling process. The possibility of removing platinum from the used catalytic converters applying pyrometallurgical and hyrdometallurgical methods were also investigated. Metals such as Cu, Pb, Ca, Mg, Cd were used in the pyrometallurgical research (catalytic converter was melted with Cu, Pb and Ca or Mg and Cd vapours were blown through the whole carrier. In hydrometallurgical research catalytic converters was dissolved in aqua regia. Analysis of Pt contents in the carrier before and after the process was performed by means of atomic absorption spectroscopy. Obtained result were discussed.

  15. Third order digital-to-analog converter

    Science.gov (United States)

    Dotson, W. P.

    1972-01-01

    System, consisting of sample and hold digital-to-analog converter, clock circuit, sample delay circuit, initial condition circuit and interpolator circuit, improves accuracy of reconstructed analog signal without increasing sample rates.

  16. (PFC) converters feeding brushless DC motor drive

    African Journals Online (AJOL)

    DR OKE

    1Department of Electrical Engineering, Indian Institute of Technology Delhi, INDIA ... configurations of PFC converters feeding BLDC motor drive are presented as low ..... In future, it is expected for a continuing research in the quest of energy ...

  17. Input-output rearrangement of isolated converters

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Kovacevic, Milovan; Mønster, Jakob Døllner

    2015-01-01

    This paper presents a new way of rearranging the input and output of isolated converters. The new arrangement posses several advantages, as increased voltage range, higher power handling capabilities, reduced voltage stress and improved efficiency, for applications where galvanic isolation...

  18. Fast simulation techniques for switching converters

    Science.gov (United States)

    King, Roger J.

    1987-01-01

    Techniques for simulating a switching converter are examined. The state equations for the equivalent circuits, which represent the switching converter, are presented and explained. The uses of the Newton-Raphson iteration, low ripple approximation, half-cycle symmetry, and discrete time equations to compute the interval durations are described. An example is presented in which these methods are illustrated by applying them to a parallel-loaded resonant inverter with three equivalent circuits for its continuous mode of operation.

  19. Solid-state power converter repeatability analysis

    CERN Document Server

    Dal Gobbo, Anthony; Aguglia, Davide

    2015-01-01

    This paper presents a method for evaluating power converter repeatability. The focus is on solid-state switch mode power converter for which the most problematic non-repeatability sources are the jitter of the drivers and of the switches leading to output voltage pulses bad repeatability. Both driver and switch turn-on and turn-off delay dispersion have been measured. These measurements confirm that the delay is Gaussian distributed and that the repeatability prediction method is valid.

  20. Switching power converters medium and high power

    CERN Document Server

    Neacsu, Dorin O

    2013-01-01

    An examination of all of the multidisciplinary aspects of medium- and high-power converter systems, including basic power electronics, digital control and hardware, sensors, analog preprocessing of signals, protection devices and fault management, and pulse-width-modulation (PWM) algorithms, Switching Power Converters: Medium and High Power, Second Edition discusses the actual use of industrial technology and its related subassemblies and components, covering facets of implementation otherwise overlooked by theoretical textbooks. The updated Second Edition contains many new figures, as well as

  1. Utilization of Nonlinear Converters for Audio Amplification

    OpenAIRE

    Iversen, Niels; Birch, Thomas; Knott, Arnold

    2012-01-01

    Class D ampliers ts the automotive demands quite well. The traditional buck-based amplier has reduced both the cost and size of ampliers. However the buck topology is not without its limitations. The maximum peak AC output voltage produced by the power stage is only equal the supply voltage. The introduction ofnon-linear converters for audio amplication defeats this limitation. A Cuk converter, designed to deliver an AC peak output voltage twice the supply voltage, is presented in this paper....

  2. ANALOG-TO-DIGITAL DATA CONVERTER

    Science.gov (United States)

    Rodgers, G.W.; Althouse, J.E.; Anderson, D.P.; Bussey, G.R.; Minnear, L.H.

    1960-09-01

    Electrical apparatus is described, particularly useful in telemetry work, for converting analog signals into electrical pulses and recording them. An electronic editor commands the taking of signal readings at a frequency which varies according to linearity of the analog signal being converted. Readings of information signals are recorded, along with time base readings and serial numbering, if desired, on magnetic tape and the latter may be used to operate a computer or the like. Magnetic tape data may be transferred to punched cards.

  3. Mitigation of EMI in a flyback converter

    OpenAIRE

    2013-01-01

    M.Ing. (Electrical & Electronic Engineering Science) This study investigates the mitigation of conducted electromagnetic interference (EMI) in a flyback DC-DC converter. Without the use of filters, the maximum mitigation of EMI possible without significantly decreasing converter operating efficiency is investigated. The following parameters are found to influence EMI: · Switching speed: Decreasing switching speed (increasing rise and fall times of the MOSFET) effectively reduces both commo...

  4. TOTAL HARMONIC DISTORTION ANALYSIS OF MATRIX CONVERTER

    OpenAIRE

    K. Kandan; Senthilkumar,K.; Dhivya, K.

    2016-01-01

    This paper deals with the validation and design analysis of Matrix converter for variable frequency using mathematical equations. The analysis was done using Venturini modulation algorithm. The PI controller is used for Matrix converter to reduce Total Harmonic Distortion (THD) in the output current. The comparative study is done for open loop and closed loop PI compensation in MATLAB-Simulink. Furthermore, the output waveforms are produced with significant reduction in the Total Harmonic Dis...

  5. LHC Power Converters: A Precision Game

    CERN Multimedia

    2001-01-01

    The LHC test-bed, String 2, is close to commissioning and one important element to get a first chance to prove what it can do is the power converter system. In String 2 there are 16 converters, in the full LHC there will be almost 1800. This article takes a look at what is so special about the power converters for the LHC. The 13 000 Amps power converters with the watercooled cables going to the String 2 feedboxes. The LHC's superconducting magnets will be the pinnacle of high technology. But to work, they'll need the help of high-precision power converters to supply them with extremely stable DC current. Perfection will be the name of the game, with an accuracy of just 1-2 parts per million (ppm) required. LEP, for the sake of comparison, could live with 10-20 ppm. The LHC's power converters will be very different from those of LEP or the SPS since the new accelerator's magnets are mostly superconducting. That means that they require much higher currents at a lower voltage since superconductors have no re...

  6. Adaptive electrothermal protection of power converters

    Directory of Open Access Journals (Sweden)

    Baraniuk G. A.

    2017-06-01

    Full Text Available Thermal management for power converters during normal operation and transient modes when electrical components are warmed up is an actual problem. This can be particularly important for converters with intermittent duty operation, e.g. power supplies for resistance welding. According to some research, nearly 60% of failures are temperature-induced, and for every 10°C temperature rise in operating environment the failure rate nearly doubles. In this paper, thermal motion of state equations eigenvalue is analysed. It is shown, that in semiconductor converters with an output smoothing filter it is appropriate to use thermal protection devices based on thermal normalisation of the converter filter and, while for cases when short circuits are possible it is appropriate to use a soft start system with thermal adaptation for soft start time factor. Based on these results, two systems of thermal protections operating for semiconductor power converters are introduced. Simulation of combined electromagnetic and thermal processes in buck converter operating with both thermal management systems in overlapping environments MATLAB/Simulink and PLECS showed the possibility to significantly reduce thermal shock on semiconductor components. Using the system of filter parameters normalisation decreases the temperature of the crystal from 210°C to 85°C, using the adaptive soft start system decreases the temperature from 180°C to 80°C. The simulation results are confirmed by tests on real devices.

  7. Isolated and soft-switched power converter

    Science.gov (United States)

    Peng, Fang Zheng; Adams, Donald Joe

    2002-01-01

    An isolated and soft-switched power converter is used for DC/DC and DC/DC/AC power conversion. The power converter includes two resonant tank circuits coupled back-to-back through an isolation transformer. Each resonant tank circuit includes a pair of resonant capacitors connected in series as a resonant leg, a pair of tank capacitors connected in series as a tank leg, and a pair of switching devices with anti-parallel clamping diodes coupled in series as resonant switches and clamping devices for the resonant leg. The power converter is well suited for DC/DC and DC/DC/AC power conversion applications in which high-voltage isolation, DC to DC voltage boost, bidirectional power flow, and a minimal number of conventional switching components are important design objectives. For example, the power converter is especially well suited to electric vehicle applications and load-side electric generation and storage systems, and other applications in which these objectives are important. The power converter may be used for many different applications, including electric vehicles, hybrid combustion/electric vehicles, fuel-cell powered vehicles with low-voltage starting, remote power sources utilizing low-voltage DC power sources, such as photovoltaics and others, electric power backup systems, and load-side electric storage and generation systems.

  8. Understanding delta-sigma data converters

    CERN Document Server

    Pavan, Shanti; Temes, Gabor C

    2017-01-01

    This new edition introduces novel analysis and design techniques for delta-sigma (ΔΣ) converters in physical and conceptual terms, and includes new chapters that explore developments in the field over the last decade. This book explains the principles and operation of delta-sigma analog-to-digital converters (ADCs) in physical and conceptual terms in accordance with the most recent developments in the field. The interest of ΔΣ converter designers has shifted significantly over the past decade, due to many new applications for data converters at the far ends of the frequency spectrum. Continuous-time delta-sigma A/D converters with GHz clocks, of both lowpass and bandpass types, are required for wireless applications. At the other extreme, multiplexed ADCs with very narrow (sometimes 10 Hz wide) signal bandwidths, but very high accuracy are needed in the interfaces of biomedical and environmental sensors. To reflect the changing eeds of designers, the second edition includes significant new material on bo...

  9. A resonant dc-dc power converter assembly

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor of the s......The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor...

  10. Converters for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng

    2015-01-01

    Power electronics technology has become the enabling technology for the integration of distributed power generation systems (DPGS) such as offshore wind turbine power systems and commercial photovoltaic power plants. Depending on the applications, a vast array of DPGS-based power converter...... presents an overview of the power converters for the DPGS, mainly based on wind turbine systems and photovoltaic systems, covering a wide range of applications. Moreover, the modulation schemes and interfacing power filters for the power converters are also exemplified. Finally, the general control...... topologies has been developed and more are coming into the market in order to achieve an efficient and reliable power conversion from the renewables. In addition, stringent demands from both the distribution system operators and the consumers have been imposed on the renewable-based DPGS. This article...

  11. Data Converter for Multistandard Mobile Phones

    DEFF Research Database (Denmark)

    Yurttas, Aziz; Bruun, Erik; Jensen, Rasmus Glarborg

    2004-01-01

    This paper describes an analog to digital converter (ADC) for mobile communication systems using a direct down conversion architecture. The ADC can be programmed to meet the requirements of different communication standards, including GSM (Global System for Mobile communication) and WCDMA (Wideband...... Code Division Multiple Access). The ADC is realized with a pipeline ADC architecture for WCDMA and a Sigma-Delta architecture for GSM. In order to have an optimized area and power consumption, the basic building blocks (opamps) of the converters are shared between the two converter architectures....... The entire ADC consumes about 5.5 mW and occupies an active area of about 0.36 mm(2). A test circuit has been developed and fabricated and measurements show that both the required programmability and the required performance can be obtained using the proposed configurations....

  12. Self-oscillating resonant power converter

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to resonant power converters and inverters comprising a self-oscillating feedback loop coupled from a switch output to a control input of a switching network comprising one or more semiconductor switches. The self-oscillating feedback loop sets a switching frequency...... of the power converter and comprises a first intrinsic switch capacitance coupled between a switch output and a control input of the switching network and a first inductor. The first inductor is coupled in-between a first bias voltage source and the control input of the switching network and has...... a substantially fixed inductance. The first bias voltage source is configured to generate an adjustable bias voltage applied to the first inductor. The output voltage of the power converter is controlled in a flexible and rapid manner by controlling the adjustable bias voltage....

  13. Metamaterial polarization converter analysis: limits of performance

    DEFF Research Database (Denmark)

    Markovich, Dmitry L.; Andryieuski, Andrei; Zalkovskij, Maksim

    2013-01-01

    In this paper, we analyze the theoretical limits of a metamaterial-based converter with orthogonal linear eigenpolarizations that allow linear-to-elliptical polarization transformation with any desired ellipticity and ellipse orientation. We employ the transmission line approach providing a needed...... level of the design generalization. Our analysis reveals that the maximal conversion efficiency for transmission through a single metamaterial layer is 50 %, while the realistic reflection configuration can give the conversion efficiency up to 90 %. We show that a double layer transmission converter...... and a single layer with a ground plane can have 100 % polarization conversion efficiency. We tested our conclusions numerically reaching the designated limits of efficiency using a simple metamaterial design. Our general analysis provides useful guidelines for the metamaterial polarization converter design...

  14. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    for advancing the reliability, availability, system robustness, and maintainability of PECS at different levels of complexity. Drawing on the experience of an international team of experts, this book explores the reliability of PECS covering topics including an introduction to reliability engineering in power...... electronic converter systems; anomaly detection and remaining-life prediction for power electronics; reliability of DC-link capacitors in power electronic converters; reliability of power electronics packaging; modeling for life-time prediction of power semiconductor modules; minimization of DC......-link capacitance in power electronic converter systems; wind turbine systems; smart control strategies for improved reliability of power electronics system; lifetime modelling; power module lifetime test and state monitoring; tools for performance and reliability analysis of power electronics systems; fault...

  15. High Efficiency Reversible Fuel Cell Power Converter

    DEFF Research Database (Denmark)

    Pittini, Riccardo

    The large scale integration of renewable energy sources requires suitable energy storage systems to balance energy production and demand in the electrical grid. Bidirectional fuel cells are an attractive technology for energy storage systems due to the high energy density of fuel. Compared...... to traditional unidirectional fuel cell, bidirectional fuel cells have increased operating voltage and current ranges. These characteristics increase the stresses on dc-dc and dc-ac converters in the electrical system, which require proper design and advanced optimization. This work is part of the PhD project...... entitled "High Efficiency Reversible Fuel Cell Power Converter" and it presents the design of a high efficiency dc-dc converter developed and optimized for bidirectional fuel cell applications. First, a brief overview of fuel cell and energy storage technologies is presented. Different system topologies...

  16. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    -link capacitance in power electronic converter systems; wind turbine systems; smart control strategies for improved reliability of power electronics system; lifetime modelling; power module lifetime test and state monitoring; tools for performance and reliability analysis of power electronics systems; fault......The main aims of power electronic converter systems (PECS) are to control, convert, and condition electrical power flow from one form to another through the use of solid-state electronics. This book outlines current research into the scientific modeling, experimentation, and remedial measures...... for advancing the reliability, availability, system robustness, and maintainability of PECS at different levels of complexity. Drawing on the experience of an international team of experts, this book explores the reliability of PECS covering topics including an introduction to reliability engineering in power...

  17. Parametric pendulum based wave energy converter

    Science.gov (United States)

    Yurchenko, Daniil; Alevras, Panagiotis

    2018-01-01

    The paper investigates the dynamics of a novel wave energy converter based on the parametrically excited pendulum. The herein developed concept of the parametric pendulum allows reducing the influence of the gravity force thereby significantly improving the device performance at a regular sea state, which could not be achieved in the earlier proposed original point-absorber design. The suggested design of a wave energy converter achieves a dominant rotational motion without any additional mechanisms, like a gearbox, or any active control involvement. Presented numerical results of deterministic and stochastic modeling clearly reflect the advantage of the proposed design. A set of experimental results confirms the numerical findings and validates the new design of a parametric pendulum based wave energy converter. Power harvesting potential of the novel device is also presented.

  18. Reliability of Power Electronic Converter Systems

    DEFF Research Database (Denmark)

    The main aims of power electronic converter systems (PECS) are to control, convert, and condition electrical power flow from one form to another through the use of solid-state electronics. This book outlines current research into the scientific modeling, experimentation, and remedial measures...... for advancing the reliability, availability, system robustness, and maintainability of PECS at different levels of complexity. Drawing on the experience of an international team of experts, this book explores the reliability of PECS covering topics including an introduction to reliability engineering in power......-link capacitance in power electronic converter systems; wind turbine systems; smart control strategies for improved reliability of power electronics system; lifetime modelling; power module lifetime test and state monitoring; tools for performance and reliability analysis of power electronics systems; fault...

  19. Nutrient removal from horticultural wastewater by benthic filamentous algae Klebsormidium sp., Stigeoclonium spp. and their communities: From laboratory flask to outdoor Algal Turf Scrubber (ATS).

    Science.gov (United States)

    Liu, Junzhuo; Danneels, Bram; Vanormelingen, Pieter; Vyverman, Wim

    2016-04-01

    Benthic filamentous algae have evident advantages in wastewater treatment over unicellular microalgae, including the ease in harvesting and resistance to predation. To assess the potentials of benthic filamentous algae in treating horticultural wastewater under natural conditions in Belgium, three strains and their mixture with naturally wastewater-borne microalgae were cultivated in 250 ml Erlenmeyer flasks in laboratory as well as in 1 m(2) scale outdoor Algal Turf Scrubber (ATS) with different flow rates. Stigeoclonium competed well with the natural wastewater-borne microalgae and contributed to most of the biomass production both in Erlenmeyer flasks and outdoor ATS at flow rates of 2-6 L min(-1) (water velocity 3-9 cm s(-1)), while Klebsormidium was not suitable for growing in horticultural wastewater under the tested conditions. Flow rate had great effects on biomass production and nitrogen removal, while phosphorus removal was less influenced by flow rate due to other mechanisms than assimilation by algae. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Impedance coordinative control for cascaded converter in bidirectional application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Deng, Fujin

    2016-01-01

    A two-stage cascaded converter is formed by connecting two sub-converters in series. Output impedance of one sub-converter will therefore interact with input impedance of the other sub-converter. Such interaction may affect the system dynamics and stability, especially when one sub-converter is c......A two-stage cascaded converter is formed by connecting two sub-converters in series. Output impedance of one sub-converter will therefore interact with input impedance of the other sub-converter. Such interaction may affect the system dynamics and stability, especially when one sub......-converter is constant-power-controlled, and hence has different impedance characteristics when its power reverses. To lessen such constant-power effects, a control scheme that can coordinate impedance behaviors of the two sub-converters is proposed. The idea is to reshape the lowfrequency negative impedance...

  1. Hydrodynamic Performance of a Wave Energy Converter

    Science.gov (United States)

    Yang, Yingchen

    2010-11-01

    To harvest energy from ocean waves, a new wave energy converter (WEC) was proposed and tested in a wave tank. The WEC freely floats on the water surface and rides waves. It utilizes its wave-driven angular oscillation to convert the mechanical energy of waves into electricity. To gain the maximum possible angular oscillation of the WEC under specified wave conditions, both floatation of the WEC and wave interaction with the WEC play critical roles in a joint fashion. During the experiments, the submersion condition of the WEC and wave condition were varied. The results were analyzed in terms of the oscillation amplitude, stability, auto-orientation capability, and wave frequency dependency.

  2. The Angiotensin-Converting-Enzyme-Induced Angioedema.

    Science.gov (United States)

    Bas, Murat

    2017-02-01

    The bradykinin B2 receptor antagonist icatibant is effective in angiotensin-converting enzyme inhibitor-induced angioedema. The drug is not approved officially for this indication and has to be administered in an emergency situation off-label. Corticosteroids or antihistamines do not seem to work in this condition. The effectiveness of C1-esterase-inhibitor in angiotensin-converting enzyme-induced angioedema must be verified in a double-blind study. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Generalized modular multilevel converter and modulation

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    Modular multilevel converter (MMC) has gained popularity recently with its modulation, capacitor voltage balancing and circulating current issues widely discussed. Contributing to this effort, a study is presented here to show how the MMC topology can be derived from the viewpoint of two series...... converters regulating a power grid. The generalized topology derived and notated as GMMC can then be altered to create various types of MMC, including the traditional topology that is presently well-known. This effort has not been previously discussed, and may smoothen the understanding of MMC operation...

  4. Soft switched DC-DC converter

    Science.gov (United States)

    Subramanian, K.; Kavitha, K. V. N.; Saravanan, K.

    2017-11-01

    A soft switched single switch isolated dc-dc conveys proposed in this paper. This converter works on the principle of zero current switching (zcs) and zero voltage switching (zvs). The circuit comprises lossless snubber with low rating. The switch works on zcs during turn on and zvs during turnoff. The diodes are based on zcs turn on and turnoff conditions. This paper presents the concept of soft switching and its applications to dc-dc converter. The losses due to soft switching and hard switching are compared.

  5. Combination solar photovoltaic heat engine energy converter

    Science.gov (United States)

    Chubb, Donald L.

    1987-01-01

    A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

  6. A quadratic analog-to-digital converter

    Science.gov (United States)

    Harrison, D. C.; Staples, M. H.

    1980-01-01

    An analog-to-digital converter with a square root transfer function has been developed for use with a pair of CCD imaging detectors in the White Light Coronagraph/X-ray XUV Telescope experiment to be flown as part of the Internal Solar Polar Mission. It is shown that in background-noise-limited instrumentation systems a quadratic analog-to-digital converter will allow a maximum dynamic range with a fixed number of data bits. Low power dissipation, moderately fast conversion time, and reliability are achieved in the proposed design using standard components and avoiding nonlinear elements.

  7. Electrodes For Alkali-Metal Thermoelectric Converters

    Science.gov (United States)

    Williams, Roger M.; Wheeler, Bob L.; Jeffries-Nakamura, Barbara; Lamb, James L.; Bankston, C. Perry; Cole, Terry

    1989-01-01

    Combination of thin, porous electrode and overlying collector grid reduces internal resistance of alkali-metal thermoelectric converter cell. Low resistance of new electrode and grid boosts power density nearly to 1 W/cm2 of electrode area at typical operating temperatures of 1,000 to 1,300 K. Conductive grid encircles electrode film on alumina tube. Bus wire runs along tube to collect electrical current from grid. Such converters used to transform solar, nuclear, and waste heat into electric power.

  8. Converting ODM Metadata to FHIR Questionnaire Resources.

    Science.gov (United States)

    Doods, Justin; Neuhaus, Philipp; Dugas, Martin

    2016-01-01

    Interoperability between systems and data sharing between domains is becoming more and more important. The portal medical-data-models.org offers more than 5.300 UMLS annotated forms in CDISC ODM format in order to support interoperability, but several additional export formats are available. CDISC's ODM and HL7's framework FHIR Questionnaire resource were analyzed, a mapping between elements created and a converter implemented. The developed converter was integrated into the portal with FHIR Questionnaire XML or JSON download options. New FHIR applications can now use this large library of forms.

  9. IGBT Based DC/DC Converter

    Directory of Open Access Journals (Sweden)

    M. Akherraz

    1997-12-01

    Full Text Available This paper presents an in-depth analytical and experimental investigation of an indirect DC-DC converter. The DC-AC conversion is a full bridge based on IGBT power modules, and the AC-DC conversion is done via a high  frequency AC link and a first diode bridge. The AC link, which consists of snubbing capacitors and a variable air-gap transformer, is analytically designed to fulfill Zero Voltage commutation requirement. The proposed converter is simulated using PSPICE and a prototype is designed built and tested in the laboratory. PSPICE simulation and experimental results are presented and compared.

  10. Efficient modelling of a modular multilevel converter

    DEFF Research Database (Denmark)

    El-Khatib, Walid Ziad; Holbøll, Joachim; Rasmussen, Tonny Wederberg

    2013-01-01

    Looking at the near future, we see that offshore wind penetration into the electrical grid will continue increasing rapidly. Until very recently, the trend has been to place the offshore wind farms close to shore within the reach for transmission using HVAC cables but for larger distances HVDC...... are calculated for the converter. Time-domain simulations on a MMC HVDC test system are performed in the PSCAD/EMTDC software environment based on the new model. The results demonstrate that the modeled MMC-HVDC system with or without converter transformer is able to operate under specific fault conditions....

  11. Efficient, lightweight dc/dc switching converter

    Science.gov (United States)

    Cuk, S.; Middlebrook, R. D.

    1981-01-01

    Converters have input properties of boost power stage and output properties of buck power stage, yet they perform general conversion function with high efficiency. Other features include non-pulsating input/output currents, use of capacitive energy transfer, low output voltage ripple, reduced EMI, and small size.

  12. Power electronics converters for wind turbine systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Liserre, Marco; Ma, Ke

    2011-01-01

    The steady growth of installed wind power which reached 200 GW capacity in 2010, together with the up-scaling of the single wind turbine power capability - 7 MW’s has been announced by manufacturers - has pushed the research and development of power converters towards full scale power conversion,...

  13. STIFF: Converting Scientific FITS Images to TIFF

    Science.gov (United States)

    Bertin, Emmanuel

    2011-10-01

    STIFF is a program that converts scientific FITS1 images to the more popular TIFF2 format for illustration purposes. Most FITS readers and converters do not do a proper job at converting FITS image data to 8 bits. 8-bit images stored in JPEG, PNG or TIFF files have the intensities implicitely stored in a non-linear way. Most current FITS image viewers and converters provide the user an incorrect translation of the FITS image content by simply rescaling linearly input pixel values. A first consequence is that the people working on astronomical images usually have to apply narrow intensity cuts or square-root or logarithmic intensity transformations to actually see something on their deep-sky images. A less obvious consequence is that colors obtained by combining images processed this way are not consistent across such a large range of surface brightnesses. Though with other software the user is generally afforded a choice of nonlinear transformations to apply in order to make the faint stuff stand out more clearly in the images, with the limited selection of choices provides, colors will not be accurately rendered, and some manual tweaking will be necessary. The purpose of STIFF is to produce beautiful pictures in an automatic and consistent way.

  14. Assay for Angiotensin-Converting Enzyme.

    Science.gov (United States)

    Russo, Salvatore F.

    1983-01-01

    Describes a three-hour experiment designed to introduce students to chemistry of the angiotensis-converting enzyme, illustrate design of a quenched fluorescence substrate, and examine considerations necessary in designing a clinical assay. Includes background information on the biochemistry of hypertension, reagents/materials needed, procedures…

  15. Online Scheduling in Distributed Message Converter Systems

    NARCIS (Netherlands)

    Risse, Thomas; Wombacher, Andreas; Surridge, Mike; Taylor, Steve; Aberer, Karl

    The optimal distribution of jobs among hosts in distributed environments is an important factor to achieve high performance. The optimal strategy depends on the application. In this paper we present a new online scheduling strategy for distributed EDI converter system. The strategy is based on the

  16. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Erah

    Pharmacotherapy Group,. Faculty of Pharmacy, University of Benin,. Benin City, 300001 Nigeria. All rights reserved. Available online at http://www.tjpr.org. Research Article. Angiotensin Converting Enzyme Insertion/Deletion. Gene Polymorphism: An Observational Study among. Diabetic Hypertensive Subjects in Malaysia.

  17. Multilevel converters for large electric drives

    Energy Technology Data Exchange (ETDEWEB)

    Tolbert, L.M.; Peng, F.Z.

    1997-11-01

    Traditional two-level high frequency pulse width modulation (PWM) inverters for motor drives have several problems associated with their high frequency switching which produces common-mode voltage and high voltage change (dV/dt) rates to the motor windings. Multilevel inverters solve these problems because their devices can switch at a much lower frequency. Two different multilevel topologies are identified for use as a converter for electric drives, a cascade inverter with separate dc sources and a back-to-back diode clamped converter. The cascade inverter is a natural fit for large automotive all electric drives because of the high VA ratings possible and because it uses several levels of dc voltage sources which would be available from batteries or fuel cells. The back to back diode damped converter is ideal where a source of ac voltage is available such as a hybrid electric vehicle. Simulation and experimental results show the superiority of these two converters over PWM based drives.

  18. Development of the Wave Energy Converter

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter; Sørensen, Hans Christian

    2000-01-01

    The development of the wave energy converter Wave Dragon (WD) is presented. The WD is based on the overtopping principle. Initially a description of the WD is given. Then the development over time in terms of the various research and development projects working with the concept is described...

  19. Aquabuoy Wave Energy Converter

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Margheritini, Lucia; Frigaard, Peter

    The work reported here is part of the contract agreement between the Finavera Renewables Ocean Energy Ltd. and the Department of Civil Engineering Hydraulics and Coastal Engineering Laboratory to instrument a model in scale 1:10 to prototype of the AquaBuOY (AB) wave energy converter and to analyse...

  20. Layout Optimisation of Wave Energy Converter Arrays

    DEFF Research Database (Denmark)

    Ruiz, Pau Mercadé; Nava, Vincenzo; Topper, Mathew B. R.

    2017-01-01

    This paper proposes an optimisation strategy for the layout design of wave energy converter (WEC) arrays. Optimal layouts are sought so as to maximise the absorbed power given a minimum q-factor, the minimum distance between WECs, and an area of deployment. To guarantee an efficient optimisation...

  1. multilevel buck converter for automotive electrical load

    African Journals Online (AJOL)

    ... from internal combustion engine (ICE). The mass production of the hybrid electric (HE) and the electric vehicle (EV) is still awaited due to subsystem inefficiencies. Increasing the efficiencies of the power converters within subsystems of these HEVs and EVs will increase the performance of the new transportation vehicles.

  2. Gourami lenses convert tryptophan into 3-hydroxykynurenine.

    Science.gov (United States)

    Truscott, R J; Wood, A M

    1994-01-01

    Although free tryptophan was found in the lens of both the kissing gourami (Helostoma temmincki) and the 3-spot gourami (Trichogaster trichopterus), only the lens of the latter species contained 3-hydroxykynurenine. Radiolabel experiments carried out on 3-spot gourami lenses in culture demonstrated that, as in humans, lenticular tryptophan is converted to 3-hydroxykynurenine probably via the intermediate kynurenine.

  3. Mathematical modeling of the flash converting process

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, H.Y.; Perez-Tello, M.; Riihilahti, K.M. [Utah Univ., Salt Lake City, UT (United States)

    1996-12-31

    An axisymmetric mathematical model for the Kennecott-Outokumpu flash converting process for converting solid copper matte to copper is presented. The model is an adaptation of the comprehensive mathematical model formerly developed at the University of Utah for the flash smelting of copper concentrates. The model incorporates the transport of momentum, heat, mass, and reaction kinetics between gas and particles in a particle-laden turbulent gas jet. The standard k-{epsilon} model is used to describe gas-phase turbulence in an Eulerian framework. The particle-phase is treated from a Lagrangian viewpoint which is coupled to the gas-phase via the source terms in the Eulerian gas-phase governing equations. Matte particles were represented as Cu{sub 2}S yFeS, and assumed to undergo homogeneous oxidation to Cu{sub 2}O, Fe{sub 3}O{sub 4}, and SO{sub 2}. A reaction kinetics mechanism involving both external mass transfer of oxygen gas to the particle surface and diffusion of oxygen through the porous oxide layer is proposed to estimate the particle oxidation rate Predictions of the mathematical model were compared with the experimental data collected in a bench-scale flash converting facility. Good agreement between the model predictions and the measurements was obtained. The model was used to study the effect of different gas-injection configurations on the overall fluid dynamics in a commercial size flash converting shaft. (author)

  4. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Purpose: This study investigated the influence of angiotensin-1 converting enzyme (ACE) insertiondeletion (ID) gene polymorphism on the treatment responses of type 2 diabetic subjects at varying stages of nephropathy to ACE inhibitors (ACEI) with regard to blood pressure (MAP) and renal response (GFR). Methods: The ...

  5. Methods for Converter Sludge Dehydration Intensification

    Science.gov (United States)

    Vakhromeev, M. I.; Moreva, Y. A.; Starkova, L. G.

    2017-11-01

    The article considers the intensification methods for converter sludge dehydration exemplified by the sludges of the Oxygen Converter Workshop (OCW) of the Open Joint-Stock Company “Magnitogorsk Iron and Steel Works” (MMK, OJSC), one of the largest metallurgical companies in the Southern Urals. Converter sludges can contain up to 45-70% of ferrum [21] which is interesting in terms of their use as an addition to a sinter-feed mixture. Sludge intensifies the sintering process. It positively influences pelletizing and fusion mixture melting dynamics at sintering. Over the period of the converter sludge dehydration complex operation at the OCW, MMK, OJSC, it was revealed that processing results in obtaining of high humidity sludge. It causes sludge freezing during the winter period, thus, its transportation involves extra costs for sludge warming up. To resolve the above-mentioned problem, the following works were performed in 2016: - experimental studies of how the application of the low-molecular anionic flocculate “SEURVEY” FL-3 influences sludge humidity reduction. - experimental studies of how the filtering press process operation parameters influence sludge humidity reduction. The new flocculate application didn't lower the dehydrated sludge humidity (the objective was the humidity of not more than 15%). Basing upon the conducted research results, we can make a conclusion that putting into operation the sewage water reactant treatment technology with the use of “SEURVEY”, FL-3 (H-10) is not recommended. The research of the influence the filtering press process parameters have on the dehydration process intensification demonstrated that reaching of the obtained residue humidity value lower than 15% is possible under the reduction of the filtering press chamber depths to 30 mm and with the application of additional operation “Residue drying” with compressed air. This way of the sludge dehydration problem resolving at filtering presses of the

  6. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...... ratio. The dc-dc converter controls the battery charge/discharge current while the grid converter controls the common dc-link voltage and the grid current. The applied control structures and the hardware implementation of both converters are presented, together with their interaction. Experimental...

  7. High-frequency matrix converter with square wave input

    Science.gov (United States)

    Carr, Joseph Alexander; Balda, Juan Carlos

    2015-03-31

    A device for producing an alternating current output voltage from a high-frequency, square-wave input voltage comprising, high-frequency, square-wave input a matrix converter and a control system. The matrix converter comprises a plurality of electrical switches. The high-frequency input and the matrix converter are electrically connected to each other. The control system is connected to each switch of the matrix converter. The control system is electrically connected to the input of the matrix converter. The control system is configured to operate each electrical switch of the matrix converter converting a high-frequency, square-wave input voltage across the first input port of the matrix converter and the second input port of the matrix converter to an alternating current output voltage at the output of the matrix converter.

  8. Dual Converter Fed Open-End Transformer Topology with Parallel Converters and Integrated Magnetics

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus

    2016-01-01

    A converter system for high power applications, connected to a medium-voltage network using a stepup transformer, is presented in this paper. The converterside winding of the transformer is configured as an openend and both the ends of the windings are fed from two different converter groups. Each...... that flows between the parallel interleaved VSCs. An integrated inductor is proposed which suppresses the circulating current in both the converter groups. In addition, the functionality of the line filter inductor is also integrated. Flux in various parts of the integrated inductor is analyzed and a design...

  9. Three-level neutral-point-clamped matrix converter topology

    OpenAIRE

    Lee, Meng Yeong

    2009-01-01

    Matrix converter is a direct AC-AC converter topology that is able to directly convert energy from an AC source to an AC load without the need of a bulky and limited lifetime energy storage element. Due to the significant advantages offered by matrix converter, such as adjustable power factor, capability of regeneration and high quality sinusoidal input/output waveforms, matrix converter has been one of the AC – AC topologies that receive extensive research attention for being an alternative ...

  10. Imbalance between pulmonary angiotensin-converting enzyme and angiotensin-converting enzyme 2 activity in acute respiratory distress syndrome

    NARCIS (Netherlands)

    Wosten-van Asperen, Roelie M.; Bos, Albert; Bem, Reinout A.; Dierdorp, Barbara S.; Dekker, Tamara; van Goor, Harry; Kamilic, Jelena; van der Loos, Chris M.; van den Berg, Elske; Bruijn, Martijn; van Woensel, Job B.; Lutter, Rene

    2013-01-01

    Objective: Angiotensin-converting enzyme and its effector peptide angiotensin II have been implicated in the pathogenesis of acute respiratory distress syndrome. Recently, angiotensin-converting enzyme 2 was identified as the counter-regulatory enzyme of angiotensin-converting enzyme that converts

  11. The incidence and nature of injuries sustained on grass and 3rd generation artificial turf: a pilot study in elite Saudi National Team footballers.

    Science.gov (United States)

    Almutawa, M; Scott, M; George, K P; Drust, B

    2014-02-01

    To compare the incidence, severity and nature of injuries sustained by Saudi National Team footballers during match-play and training on natural grass and 3rd generation (3G) artificial turf. Injury data was collected on all Saudi National Team players competing at the Gulf Cup (Yemen December 2010: 3G) and the Asian Cup (Qatar January 2011; grass). A total of 49 players were studied (mean ± SD; Age 27 ± 4 yr; body mass 71.4 ± 6.7 kg; height 176.8 ± 6.3 cm; professional playing experience 9 ± 3 yr) of which 31 competed at the Gulf Cup, 32 at the Asian Cup (14 at both). A prospective cohort design was used to investigate the incidence, nature and severity of injuries sustained with data collected using a standardised injury questionnaire. All data were collected by the team physiotherapist with the definition of injury set at any injury that required player and clinician contact. Injury and exposure data were collected and reported for games, training and all football activity. A total of 82 injuries [incidence - 56.1 per 1000 h total game and training exposure] were recorded at the Asian Cup (grass) and 72 injuries [incidence - 37.9 per 1000 h total game and training exposure] were recorded at the Gulf Cup (3G). Incidence data for training, game and all football exposure injury rates were higher when playing on grass. The vast majority of injuries on both surfaces were very minor that, whilst requiring medical attention, did not result in loss of match/training exposure. Injuries that resulted in 1-3 days absence from training or game play had similar incidence rates (Grass: 7.4 vs. 3G: 7.4 injuries per 1000 h exposure). More severe injuries were less frequent but with a higher incidence when playing on grass. Lower limb injuries were the most common in both tournaments with a higher incidence on grass (Grass: 14.2 vs. 3G: 7.9 injuries per 1000 h exposure). Muscle injuries were the most frequent of all injuries with similar incidence rates on

  12. Analog-digital converters for industrial applications including an introduction to digital-analog converters

    CERN Document Server

    Ohnhäuser, Frank

    2015-01-01

    This book offers students and those new to the topic of analog-to-digital converters (ADCs) a broad introduction, before going into details of the state-of-the-art design techniques for SAR and DS converters, including the latest research topics, which are valuable for IC design engineers as well as users of ADCs in applications. The book then addresses important topics, such as correct connectivity of ADCs in an application, the verification, characterization and testing of ADCs that ensure high-quality end products. Analog-to-digital converters are the central element in any data processing system and regulation loops such as modems or electrical motor drives. They significantly affect the performance and resolution of a system or end product. System development engineers need to be familiar with the performance parameters of the converters and understand the advantages and disadvantages of the various architectures. Integrated circuit development engineers have to overcome the problem of achieving high per...

  13. Multi-output DC-DC converters based on diode-clamped converters configuration

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ghosh, A.

    2010-01-01

    for a diode-clamed inverter in the grid connection systems, where boosting low rectified output-voltage and series DC link capacitors is required. To verify the proposed topology, steady-state and dynamic analyses of a MOB converter are examined. A simple control strategy has been proposed to demonstrate......This study presents a new DC DC multi-output boost (MOB) converter which can share its total output between different series of output voltages for low- and high-power applications. This configuration can be utilised instead of several single output power supplies. This is a compatible topology...... the performance of the proposed topology for a double-output boost converter. The topology and its control strategy can easily be extended to offer multiple outputs. Simulation and experimental results are presented to show the validity of the control strategy for the proposed converter....

  14. The Multi-Scale Response of Water Quality, Biodiversity and Carbon Sequestration to Coupled Macronutrient Cycling from Source to Sea: TURF2SURF

    Science.gov (United States)

    Wade, Andrew; Emmett, Bridget; Jago, Colin; Stutter, Marc; Biggs, Jeremy

    2016-04-01

    Turf2Surf is a large, multi-disciplinary project that aims to test the hypothesis that the spatial and temporal patterns of water quality, C sequestration and biodiversity are better explained through the large-scale coupling of C, N and P cycles than by single cycle, single system approaches. To achieve this, a catchment-scale study of the River Conwy (349 km2) in Wales is being done with emphasis on determining when, where and how coupled macronutrient (C, N, P) cycling occurs in the biogeochemical hot-spots of the soils, the riparian zone, instream and in the river-estuarine transition zone. A major integrated measurement programme is now largely complete. New data are being analysed to understand which soil properties have greatest influence on above and below-ground productivity including plant traits and how microbial processing is controlled by stoichiometry and nutrient priming. Within the stream network, new understanding is being produced on the in-river algal and whole ecosystem (metabolic) response to CNP additions and the factors affecting the fate and cycling of organic matter. In the estuary, initial results indicate a subsurface jet is causing stratification and a velocity anomaly has been observed. Both are important in terms of suspended matter transport and floc break-up. An integrated model is being built to describe the soil-atmosphere-vegetation processes which is linked, firstly, to flow and water quality models that describe the CNP flux transport and transformations from the headwaters to the estuary and, secondly, to biodiversity models. The purpose of the integrated model is to quantify how coupled CNP cycles may respond to environmental change and thereby affect C sequestration, water quality and biodiversity in the future. The team are now in the major phase of data synthesis and model development and are interested in linking with similar studies involving coupled CNP cycles across the atmospheric

  15. A Variational Inequality from Pricing Convertible Bond

    Directory of Open Access Journals (Sweden)

    Yan Huiwen

    2011-01-01

    Full Text Available The model of pricing American-style convertible bond is formulated as a zero-sum Dynkin game, which can be transformed into a parabolic variational inequality (PVI. The fundamental variable in this model is the stock price of the firm which issued the bond, and the differential operator in PVI is linear. The optimal call and conversion strategies correspond to the free boundaries of PVI. Some properties of the free boundaries are studied in this paper. We show that the bondholder should convert the bond if and only if the price of the stock is equal to a fixed value, and the firm should call the bond back if and only if the price is equal to a strictly decreasing function of time. Moreover, we prove that the free boundaries are smooth and bounded. Eventually we give some numerical results.

  16. Boost Converter with Active Snubber Network

    Directory of Open Access Journals (Sweden)

    HIMMELSTOSS, F. A.

    2017-02-01

    Full Text Available A new concept for reducing the losses in a boost converter is described. With the help of an auxiliary switch and a resonant circuit, zero-voltage switching at turn-off and zero-current switching during turn-on are achieved. The modes of the circuit are shown in detail. The energy recovery of the turn-off is analyzed and the recovered energy is calculated; an optimized switching concept therefore is described. The influence of the parasitic capacity of the switch is discussed. Dimensioning hints for the converter and the design of the recuperation circuit are given. A bread-boarded design shows the functional efficiency of the concept.

  17. Terahertz broadband polarization converter based on metamaterials

    Science.gov (United States)

    Li, Yonghua; Zhao, Guozhong

    2018-01-01

    Based on the metamaterial composed of symmetrical split resonant ring, a broadband reflective terahertz polarization converter is proposed. The numerical simulation shows that it can rotate the polarization direction of linear polarized wave 90° in the range of 0.7-1.8THz and the polarization conversion ratio is over 90%. The reflection coefficient of the two electric field components in the diagonal direction is the same and the phase difference is 180° ,which leads to the cross-polarization rotation.In order to further study the physical mechanism of high polarization conversion, we analyze the surface current distribution of the resonant ring. The polarization converter has potential applications in terahertz wave plate and metamaterial antenna design.

  18. Component technology for Stirling power converters

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, L.G.

    1994-09-01

    NASA Lewis Research Center has organized a component technology program as part of the efforts to develop Stirling converter technology for space power applications. The Stirling space power program is part of the NASA High Capacity Power Project of the Civil Space Technology Initiative (CSTI). NASA Lewis is also providing technical management for a DOE/Sandia program to develop Stirling converters for solar terrestrial power producing electricity for the utility grid. The primary contractors for the space power and solar terrestrial programs develop component technologies directly related to their program goals. This Lewis component technology effort, while coordinated with the main programs, aims at longer term issues, advanced technologies, and independent assessments. This paper will present an overview of work on linear alternators, engine/alternator/load interactions and controls, heat exchangers, materials, life and reliability, and bearings.

  19. MOCCASIN: converting MATLAB ODE models to SBML.

    Science.gov (United States)

    Gómez, Harold F; Hucka, Michael; Keating, Sarah M; Nudelman, German; Iber, Dagmar; Sealfon, Stuart C

    2016-06-15

    MATLAB is popular in biological research for creating and simulating models that use ordinary differential equations (ODEs). However, sharing or using these models outside of MATLAB is often problematic. A community standard such as Systems Biology Markup Language (SBML) can serve as a neutral exchange format, but translating models from MATLAB to SBML can be challenging-especially for legacy models not written with translation in mind. We developed MOCCASIN (Model ODE Converter for Creating Automated SBML INteroperability) to help. MOCCASIN can convert ODE-based MATLAB models of biochemical reaction networks into the SBML format. MOCCASIN is available under the terms of the LGPL 2.1 license (http://www.gnu.org/licenses/lgpl-2.1.html). Source code, binaries and test cases can be freely obtained from https://github.com/sbmlteam/moccasin : mhucka@caltech.edu More information is available at https://github.com/sbmlteam/moccasin. © The Author 2016. Published by Oxford University Press.

  20. Converter topologies for common mode voltage reduction

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Fernando

    2017-11-21

    An inverter includes a three-winding transformer, a DC-AC inverter electrically coupled to the first winding of the transformer, a cycloconverter electrically coupled to the second winding of the transformer, and an active filter electrically coupled to the third winding of the transformer. The DC-AC inverter is adapted to convert the input DC waveform to an AC waveform delivered to the transformer at the first winding. The cycloconverter is adapted to convert an AC waveform received at the second winding of the transformer to the output AC waveform having a grid frequency of the AC grid. The active filter is adapted to sink and source power with one or more energy storage devices based on a mismatch in power between the DC source and the AC grid. At least two of the DC-AC inverter, the cycloconverter, or the active filter are electrically coupled via a common reference electrical interconnect.

  1. MAGIC: Model and Graphic Information Converter

    Science.gov (United States)

    Herbert, W. C.

    2009-01-01

    MAGIC is a software tool capable of converting highly detailed 3D models from an open, standard format, VRML 2.0/97, into the proprietary DTS file format used by the Torque Game Engine from GarageGames. MAGIC is used to convert 3D simulations from authoritative sources into the data needed to run the simulations in NASA's Distributed Observer Network. The Distributed Observer Network (DON) is a simulation presentation tool built by NASA to facilitate the simulation sharing requirements of the Data Presentation and Visualization effort within the Constellation Program. DON is built on top of the Torque Game Engine (TGE) and has chosen TGE's Dynamix Three Space (DTS) file format to represent 3D objects within simulations.

  2. Analog current mode analog/digital converter

    Science.gov (United States)

    Hadidi, Khayrollah (Inventor)

    1996-01-01

    An improved subranging or comparator circuit is provided for an analog-to-digital converter. As a subranging circuit, the circuit produces a residual signal representing the difference between an analog input signal and an analog of a digital representation. This is achieved by subdividing the digital representation into two or more parts and subtracting from the analog input signal analogs of each of the individual digital portions. In another aspect of the present invention, the subranging circuit comprises two sets of differential input pairs in which the transconductance of one differential input pair is scaled relative to the transconductance of the other differential input pair. As a consequence, the same resistor string may be used for two different digital-to-analog converters of the subranging circuit.

  3. Component technology for Stirling power converters

    Science.gov (United States)

    Thieme, Lanny G.

    1991-01-01

    NASA Lewis Research Center has organized a component technology program as part of the efforts to develop Stirling converter technology for space power applications. The Stirling Space Power Program is part of the NASA High Capacity Power Project of the Civil Space Technology Initiative (CSTI). NASA Lewis is also providing technical management for the DOE/Sandia program to develop Stirling converters for solar terrestrial power producing electricity for the utility grid. The primary contractors for the space power and solar terrestrial programs develop component technologies directly related to their goals. This Lewis component technology effort, while coordinated with the main programs, aims at longer term issues, advanced technologies, and independent assessments. An overview of work on linear alternators, engine/alternator/load interactions and controls, heat exchangers, materials, life and reliability, and bearings is presented.

  4. Strained quantum well photovoltaic energy converter

    Science.gov (United States)

    Freundlich, Alexandre (Inventor); Renaud, Philippe (Inventor); Vilela, Mauro Francisco (Inventor); Bensaoula, Abdelhak (Inventor)

    1998-01-01

    An indium phosphide photovoltaic cell is provided where one or more quantum wells are introduced between the conventional p-conductivity and n-conductivity indium phosphide layer. The approach allows the cell to convert the light over a wider range of wavelengths than a conventional single junction cell and in particular convert efficiently transparency losses of the indium phosphide conventional cell. The approach hence may be used to increase the cell current output. A method of fabrication of photovoltaic devices is provided where ternary InAsP and InGaAs alloys are used as well material in the quantum well region and results in an increase of the cell current output.

  5. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    . Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. Thisimplicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development...... stages, and results thereby in a need for specific testobjectives and procedures for each development stage. This PhD thesis has looked into the different development stages and more specifically in the performance assessment of wave energy converters based on tank testing and sea trials. The objective......Ocean waves provide a sustainable, power-dense, predictable and widely available source of energy that could provide about 10 % of worlds energy needs. While research into waveenergy has been undertaken for decades, a significant increase in related activities has been seen in the recent years...

  6. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    . Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. This implicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development...... stages, and results thereby in a need for specific test objectives and procedures for each development stage. This PhD thesis has looked into the different development stages and more specifically in the performance assessment of wave energy converters based on tank testing and sea trials. The objective......Ocean waves provide a sustainable, power-dense, predictable and widely available source of energy that could provide about 10 % of worlds energy needs. While research into wave energy has been undertaken for decades, a significant increase in related activities has been seen in the recent years...

  7. Performance Evaluation of Waste Plastic Oil Converter

    Directory of Open Access Journals (Sweden)

    Elmo C. Rapsing, Jr.

    2017-05-01

    Full Text Available This research aimed to evaluate the performance of the waste plastic oil converter. The equipment is a prototype model powered by electricity and utilizes a non-catalytic pyrolysis process of converting waste plastic to oil. The primary objective of the study is to identify the type of waste plastic that the equipment can process and determine its performance in terms of conversion efficiency (wt %, waste reduction efficiency (wt % and oil recovery (ml oil/kg waste plastic. The equipment was initially tested for Type 1-Polyethylene Terephthalate, Type 2-High Density Polyethylene, Type 4-Low Density Polyethylene, Type 5-Polypropylene and Type 6 -Polystyrene. It was observed that the equipment is only capable of converting Type 5 and 6 waste plastic into oil. For the performance evaluation of the equipment, 1000g Type 5 and 1000g Type 6 waste plastic were used as feedstock. The experiments were performed separately for each of them. Five trials using 200g per trial for each type of plastic was conducted to test the equipment. The temperature at the bottom of the reactor was set to 4000C and the operating time was 2 hour per trial with 15 minutes cracking time, 1 minute vapor residence time and 1 minute vapor evacuation time. Results show that the conversion efficiency of the equipment for Type 5 was 60.90% and for Type 6 was 83.6%. Waste reduction efficiency was 94.8% for Type 5 and 95.6% for Type 6. The oil recovery of the equipment was 766 ml/kg for Type 5 and 919 ml/kg for Type 6. Thus, the waste plastic oil converter is a potential solution in reducing the amount of plastic waste due to its capability of producing oil out ofwaste Type 5 and Type 6 plastics.

  8. Reversible thyristor converters of brushless synchronous compensators

    Directory of Open Access Journals (Sweden)

    А.М.Galynovskiy

    2013-12-01

    Full Text Available Behavior of models of three-phase-to-single-phase rotary reversible thyristor converters of brushless synchronous compensators in a circuit simulation system is analyzed. It is shown that combined control mode of opposite-connected thyristors may result in the exciter armature winding short circuits both at the thyristor feed-forward and lagging current delay angles. It must be taken into consideration when developing brushless compensator excitation systems.

  9. Converting low dose radiation to redox signaling

    OpenAIRE

    Pristov, Jelena Bogdanović; Spasić, Mihajlo; Spasojević, Ivan

    2013-01-01

    In contrast to the damaging effects of high doses, low dose radiation (UV, gamma) has been reported to provoke constructive changes in plants. However, the mechanisms by which plants recognize and respond to low dose radiation are not understood. We have shown recently that polygalacturonic acid, cell wall polysaccharide, converts the highly reactive product of radiation - hydroxyl radical into superoxide which may be further dismutated to hydrogen peroxide. Superoxide has been proposed to ac...

  10. Fracture imaging with converted elastic waves

    Energy Technology Data Exchange (ETDEWEB)

    Nihei, K.T.; Nakagawa, S.; Myer, L.R.

    2001-05-29

    This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

  11. Three-phase Resonant DC-link Converter

    DEFF Research Database (Denmark)

    Munk-Nielsen, Stig

    . The high speed of the switches cannot be fully utilizied. By using a parallel resonant converter the switching happens at low or zero voltage which reduses switch losses. The dv/dt is controlled by the resonant circuit, and it is therefore reduced significantly. The perspective using a resonant converter...... is high switching frequency combined with a high converter efficiency and low dv/dt. In the first report several resonant converters are investigated to find a resonant converter that can complete with the standard PWM-VSI converter. Four converters were selected for the theoretical analysis....... A resonant converter efficiency of 97 [%] was measured. The low dv/dt of the converter makes it possible to drive long cables without filtering. A successful test with a 300 [m] long cable and an induction machine load was carried out. It is concluded that a stable, high efficiency and high switching...

  12. Converter fed sub sea motor drives

    Energy Technology Data Exchange (ETDEWEB)

    Raad, R.O.

    1995-09-01

    Minor offshore gas and oil resources located 20-50 km from existing installations may often be commercially exploited only by use of complete sub sea solutions. This thesis deals with analyses of a sub sea adjustable speed electric motor which is fed by a frequency converter via a long cable (up to 50 km) between the converter and the motor. The author develops a general model for analysing such motor drive systems with the objective of verifying the feasibility of specific applications and of specifying the requirements on the system components. The simulation model is used to identify the critical frequency ranges in which the converter must not generate significant harmonics, to verify the start-up strategy chosen, and to verify the stability with potential disturbances applied to the system. Simulation models are developed for both transient and steady state analyses. They are accurate up to 5 kHz and can incorporate the frequency dependency of the motor and cable parameters. Ideal thyristors and diodes are used. The models are implemented in existing simulation tools. Most of the results relate to a base case with a 670 kW squirrel cage motor fed from a 30 km long cable, but cases with 3 MW rating or with 50 km cable have also been analyzed and found to be feasible. Each specific application must be separately studied. Results of simulation calculations are presented and conclusions given. 53 refs., 124 figs., 23 tabs.

  13. Fault isolation in parallel coupled wind turbine converters

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Thøgersen, Paul Bach; Stoustrup, Jakob

    2010-01-01

    Parallel converters in wind turbine give a number advantages, such as fault tolerance due to the redundant converters. However, it might be difficult to isolate gain faults in one of the converters if only a combined power measurement is available. In this paper a scheme using orthogonal power...... references to the converters is proposed. Simulations on a wind turbine with 5 parallel converters show a clear potential of this scheme for isolation of this gain fault to the correct converter in which the fault occurs....

  14. Novel screening techniques for wind turbine power converters

    DEFF Research Database (Denmark)

    Jørgensen, Asger Bjørn; Sønderskov, Simon Dyhr; Christensen, Nicklas

    2016-01-01

    Power converters represent one of the highest failure rates in the wind turbine. Therefore converter manufacturers perform burn-in tests to prevent shipping of faulty converters. Recent developments in junction temperature estimation, based on accurate online IGBT collector-emitter voltage...... converters for wind turbines applications....... measurements, allow for thermal stress estimation of the IGBT modules. This is utilized to detect infant mortalities in power converters, by comparing thermal responses of IGBTs for faulty and non-faulty converters. The method proves to be a time and cost efficient candidate to replace burn-in tests of power...

  15. One-Quadrant Switched-Mode Power Converters

    CERN Document Server

    Petrocelli, R.

    2015-06-15

    This article presents the main topics related to one-quadrant power convert- ers. The basic topologies are analysed and a simple methodology to obtain the steady-state output–input voltage ratio is set out. A short discussion of dif- ferent methods to control one-quadrant power converters is presented. Some of the reported derived topologies of one-quadrant power converters are also considered. Some topics related to one-quadrant power converters such as syn- chronous rectification, hard and soft commutation, and interleaved converters are discussed. Finally, a brief introduction to resonant converters is given.

  16. Modulation and control of matrix converter for aerospace application

    Science.gov (United States)

    Kobravi, Keyhan

    In the context of modern aircraft systems, a major challenge is power conversion to supply the aircraft's electrical instruments. These instruments are energized through a fixed-frequency internal power grid. In an aircraft, the available sources of energy are a set of variable-speed generators which provide variable-frequency ac voltages. Therefore, to energize the internal power grid of an aircraft, the variable-frequency ac voltages should be converted to a fixed-frequency ac voltage. As a result, an ac to ac power conversion is required within an aircraft's power system. This thesis develops a Matrix Converter to energize the aircraft's internal power grid. The Matrix Converter provides a direct ac to ac power conversion. A major challenge of designing Matrix Converters for aerospace applications is to minimize the volume and weight of the converter. These parameters are minimized by increasing the switching frequency of the converter. To design a Matrix Converter operating at a high switching frequency, this thesis (i) develops a scheme to integrate fast semiconductor switches within the current available Matrix Converter topologies, i.e., MOSFET-based Matrix Converter, and (ii) develops a new modulation strategy for the Matrix Converter. This Matrix Converter and the new modulation strategy enables the operation of the converter at a switching-frequency of 40kHz. To provide a reliable source of energy, this thesis also develops a new methodology for robust control of Matrix Converter. To verify the performance of the proposed MOSFET-based Matrix Converter, modulation strategy, and control design methodology, various simulation and experimental results are presented. The experimental results are obtained under operating condition present in an aircraft. The experimental results verify the proposed Matrix Converter provides a reliable power conversion in an aircraft under extreme operating conditions. The results prove the superiority of the proposed Matrix

  17. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  18. Coordinated Control of Wave Energy Converters Subject to Motion Constraints

    National Research Council Canada - National Science Library

    Wang, Liguo; Engström, Jens; Leijon, Mats; Isberg, Jan

    2016-01-01

    ...) damping of each wave energy converter in the frequency domain in each sea state. In a case study, a wave energy farm consisting of four converters based on the concept developed by Uppsala University is studied...

  19. Highly linear, sensitive analog-to-digital converter

    Science.gov (United States)

    Cox, J.; Finley, W. R.

    1969-01-01

    Analog-to-digital converter converts 10 volt full scale input signal into 13 bit digital output. Advantages include high sensitivity, linearity, low quantitizing error, high resistance to mechanical shock and vibration loads, and temporary data storage capabilities.

  20. Stability of interacting grid-connected power converters

    National Research Council Canada - National Science Library

    Wan, Cheng; Huang, Meng; Tse, Chi K; Ruan, Xinbo

    2013-01-01

    .... Thus, grid-connected converters interact with each other via the non-ideal grid. In this study, we consider the practical scenario of voltage-source converters connected to a three-phase voltage source with significant impedance...

  1. Optical analog-to-digital converter

    Science.gov (United States)

    Evanchuk, Vincent L. (Inventor)

    1984-01-01

    A method and apparatus for converting the intensity of an unknown optical signal (B) into an electrical signal in digital form utilizes two elongated optical attenuators (11, 13), one for the unknown optical signal from a source (10) and one for a known optical signal (A) from a variable source (12), a plurality of photodetectors (e.g., 17, 18) along each attenuator for detecting the intensity of the optical signals, and a plurality of comparators (e.g., 21) connected to the photodetectors in pairs to determine at what points being compared the attenuated known signal equals the attenuated unknown signal. The intensity of the unknown relative to the known is thus determined by the output of a particular comparator. That output is automatically encoded to a relative intensity value in digital form through a balancing feedback control (24) and encoder (23). The digital value may be converted to analog form in a D-to-A converter (27) and used to vary the source of the known signal so that the attenuated intensity of the known signal at a predetermined point (comparator 16) equals the attenuated intensity of the unknown signal at the predetermined point of comparison. If the known signal is then equal to the unknown, there is verification of the analog-to-digital conversion being complete. Otherwise the output of the comparator indicating equality at some other point along the attenuators will provide an output which is encoded and added, through an accumulator comprised of a register (25) and an adder (26), to a previous relative intensity value thereby to further vary the intensity of the known signal source. The steps are repeated until full conversion is verified.

  2. Faults and Diagnosis Systems in Power Converters

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Choi, Uimin

    2014-01-01

    frequently. Therefore, it is important to monitor the power device and capacitor fault to increase the reliability of power electronics. In this chapter, the diagnosis methods for power device fault will be discussed by dividing into open- and short-circuit faults. Then, the condition monitoring methods...... efforts have been put into making these systems better in terms of reliability in order to achieve high power source availability, reduce the cost of energy and also increase the reliability of overall systems. Among the components used in power converters, a power device and a capacitor fault occurs most...

  3. Capacitor Monitoring for Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Deng, Fujin; Liu, Dong; Wang, Yanbo

    2017-01-01

    The modular multilevel converter (MMC) is attractive for medium- or high-power applications because of the advantages of its high modularity, availability, and high power quality. Reliability is one of the most important challenges for the MMC consisting of a large number of submodules (SMs......). The capacitor monitoring in each SM of the MMC is an important issue, which would affect the performance of the MMC. This paper proposed an effective monitoring method for the capacitance in each SM of the MMC. The proposed method reveals the relationship between the arm average capacitance and the capacitance...

  4. Converting skeletal structures to quad dominant meshes

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Misztal, Marek Krzysztof; Welnicka, Katarzyna

    2012-01-01

    We propose the Skeleton to Quad-dominant polygonal Mesh algorithm (SQM), which converts skeletal structures to meshes composed entirely of polar and annular regions. Both types of regions have a regular structure where all faces are quads except for a single ring of triangles at the center of each...... polar region. The algorithm produces high quality meshes which contain irregular vertices only at the poles or where several regions join. It is trivial to produce a stripe parametrization for the output meshes which also lend themselves well to polar subdivision. After an initial description of SQM, we...

  5. Design, modeling and testing of data converters

    CERN Document Server

    Kiaei, Sayfe; Xu, Fang

    2014-01-01

    This book presents the a scientific discussion of the state-of-the-art techniques and designs for modeling, testing and for the performance analysis of data converters. The focus is put on sustainable data conversion. Sustainability has become a public issue that industries and users can not ignore. Devising environmentally friendly solutions for data conversion designing, modeling and testing is nowadays a requirement that researchers and practitioners must consider in their activities. This book presents the outcome of the IWADC workshop 2011, held in Orvieto, Italy.

  6. Dead time optimization method for power converter

    Science.gov (United States)

    Deselaers, C.; Bergmann, U.; Gronwald, F.

    2013-07-01

    This paper introduces a method for dead time optimization in variable speed motor drive systems. The aim of this method is to reduce the conduction time of the freewheeling diode to a minimum without generation of cross conduction. This results in lower losses, improved EMC, and less overshooting of the phase voltage. The principle of the method is to detect beginning cross currents without adding additional components in the half bridge like resistors or inductances. Only the wave shape of the phase voltage needs to be monitored during switching. This is illustrated by an application of the method to a real power converter.

  7. Near-Shore Floating Wave Energy Converters

    DEFF Research Database (Denmark)

    Ruol, Piero; Zanuttigh, Barbara; Martinelli, Luca

    2011-01-01

    Aim of this note is to analyse the possible application of a Wave Energy Converter (WEC) as a combined tool to protect the coast and harvest energy. Physical model tests are used to evaluate wave transmission past a near-shore floating WEC of the wave activated body type, named DEXA. Efficiency...... and transmission characteristics are approximated to functions of wave height, period and obliquity. Their order of magnitude are 20% and 80%, respectively. It is imagined that an array of DEXA is deployed in front of Marina di Ravenna beach (IT), a highly touristic site of the Adriatic Coast. Based on the CERC...

  8. Waste Plastic Converting into Hydrocarbon Fuel Materials

    Energy Technology Data Exchange (ETDEWEB)

    Sarker, Moinuddin; Mamunor Rashid, Mohammad; Molla, Mohammad

    2010-09-15

    The increased demand and high prices for energy sources are driving efforts to convert organic compounds into useful hydrocarbon fuels. Although much of this work has focused on biomass, there are strong benefits to deriving fuels from waste plastic material. Natural State Research Inc. (NSR) has invented a simple and economically viable process to decompose the hydrocarbon polymers of waste plastic into the shorter chain hydrocarbon of liquid fuel (patent pending). The method and principle of the production / process will be discussed. Initial tests with several widely used polymers indicate a high potential for commercialization.

  9. Power converters for medium voltage networks

    CERN Document Server

    Islam, Md Rabiul; Zhu, Jianguo

    2014-01-01

    This book examines a number of topics, mainly in connection with advances in semiconductor devices and magnetic materials and developments in medium and large-scale renewable power plant technologies, grid integration techniques and new converter topologies, including advanced digital control systems for medium-voltage networks. The book's individual chapters provide an extensive compilation of fundamental theories and in-depth information on current research and development trends, while also exploring new approaches to overcoming some critical limitations of conventional grid integration te

  10. Converting Afrikaans to Dutch for technology recycling

    OpenAIRE

    Pilon, Suléne; van Huyssteen, Gerhard; Augustinus, Liesbeth

    2010-01-01

    HLT resource development for a resource scarce language (L2) can be expedited by recycling existing technologies for a closely related language (L1). To improve the success of L1 technologies on L2 data, one can convert L2 data to make it appear more L1-like. We explore this possibility by developing an Afrikaans-to-Dutch lexical conversion module and using it as pre-processing step before applying a Dutch part of speech tagger to Afrikaans data. The accuracy of the Dutch tagger increased ...

  11. A New Modular Multilevel Converter with Integrated Energy Storage

    DEFF Research Database (Denmark)

    Trintis, Ionut; Munk-Nielsen, Stig; Teodorescu, Remus

    2011-01-01

    This paper introduces a new modular converter with integrated energy storage based on the cascaded half-bridge modular multilevel converter with common DC bus. It represents a complete modular solution with power electronics and energy storage building blocks, for medium and high voltage...... in the future HVDC meshed grids. Its functionality and flexibility makes the converter independent on the energy storage unit characteristic. The converter concept with its basic functions and control schemes are described and evaluated in this paper....

  12. Highly-Efficient and Modular Medium-Voltage Converters

    Science.gov (United States)

    2015-09-28

    of the modular multilevel converter based on si and sic switching devices for medium/high-voltage applications," IEEE Trans. Electron Devices, vol...4. TITLE AND SUBTITLE Highly-Efficient and Modula Medium-Voltage Converters 6. AUTHOR(S) Maryam Saeedifard 7. PERFORMING ORGANIZATIC i NAME(S...improving the converter’s efficiency and power density. 15. SUBJECT TERMS Modular Multilevel Converters , DC-DC Conversion, DC-AC Conversion 16

  13. Estimation on the switching losses at IGBT bridges power converter

    OpenAIRE

    Stefanov, Goce; Karacinov, Ljupco; Cundev, Dobri

    2011-01-01

    ABSTRACT. In the paper estimation on the switching losses at IGBT bridge converter with the output serial resonant load is given. The converter works on frequency higher than resonant frequency and supports the work of IGBT transistors in the bridge with zero voltage turn on. In the analysis of the converter, PowerSim and SemiSiel simulation programs is used. The results to the switching losses estimated by simulation are compared with the results in a practical realized converter.

  14. Novel Vortex Generator and Mode Converter for Electron Beams

    OpenAIRE

    Schattschneider, P.; Stoeger-Pollach, M.; Verbeeck, J.

    2012-01-01

    Abstract: A mode converter for electron vortex beams is described. Numerical simulations, confirmed by experiment, show that the converter transforms a vortex beam with a topological charge m = +/- 1 into beams closely resembling Hermite-Gaussian HG(10) and HG(01) modes. The converter can be used as a mode discriminator or filter for electron vortex beams. Combining the converter with a phase plate turns a plane wave into modes with topological charge m = +/- 1. This combination serves as a g...

  15. Development of a test platform for controlling parallel converters

    DEFF Research Database (Denmark)

    Bede, Lorand; Kopacz, Csaba; Kerekes, Tamas

    2014-01-01

    a proper interleaving angle between the converters the current ripple can be reduced considerably. In order to be able to investigate the performance of these converters a safe and cheap platform is essential. The development of a test platform for such an application is challenging, since a proper...... synchronization has to be established between the converters. In this paper a universal platform is presented, which allows to parallel n converters with arbitrary interleaving angle between each other....

  16. Three new DC-to-DC Single-Switch Converters

    OpenAIRE

    Barry W. Williams; Mona Fouad Moussa

    2017-01-01

    This paper presents a new family of three previously unidentified dc-to-dc converters, buck, boost, and buck-boost voltage-transfer-function topologies, which offer advantageous transformer coupling features and low capacitor dc voltage stressing. The three single-switch, single-diode, converters offer the same features as basic dc-to-dc converters, such as the buck function with continuous output current and the boost function with continuous input current. Converter time-domain simulations ...

  17. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    points in this type of converter is dc-voltage control. In this paper, a novel multi output dc-dc converter connected to a diode clamped topology is presented. This converter, for a given duty cycles, is able to regulate the capacitor voltage to provide an appropriate input voltage for NPC regardless...

  18. Use of Electrically Heated Metal Catalytic Converter in Cold Starting ...

    African Journals Online (AJOL)

    The easiest way to preheat the converter is to use electric resistance heaters. The electrical systems on most cars provide enough energy or power to heat the catalytic converter fast enough. So, in this research the main converter remains its usual position, whereas the heated catalyst is placed close to the exhaust manifold ...

  19. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path...

  20. Convertible Arbitrage Price Pressure and Short-Sale Constraints

    NARCIS (Netherlands)

    de Jong, Abe; Dutordoir, Marie; van Genuchten, Nathalie; Verwijmeren, Patrick

    2012-01-01

    Using a sample of 4,148 convertibles issued over 1990-2009 by companies listed in 35 countries, the authors exploited worldwide differences in short-sale constraints to examine whether short selling by convertible arbitrageurs creates downward pressure on convertible issuers' stock prices. They

  1. Isolated Boost Converter with Bidirectional Operation for Supercapacitor Applications

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gökhan

    2013-01-01

    This paper presents an isolated bidirectional dc/dc converter based on primary parallel isolated boost converter (PPIBC). This topology is an efficient solution in low voltage high power applications due to its ability to handle high currents in the low voltage side. In this paper, the converter ...

  2. New configurations of power converters for grid interconnection systems

    OpenAIRE

    Rivera, Marco; Toleda, Sergio; Nasir, Usman; Costabeber, Alessando; Wheeler, Patrick

    2016-01-01

    The increased penetration of renewable energy sources and other distributed energy sources has been seen nowadays. In this scenario power converters play a crucial role by providing the interconnection of these energy sources. This paper presents new configurations of power converters for grid interconnection systems. Several topologies are analyzed which are based on isolated ac-ac matrix converters.

  3. 26 CFR 1.544-5 - Convertible securities.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Convertible securities. 1.544-5 Section 1.544-5...) INCOME TAXES (CONTINUED) Personal Holding Companies § 1.544-5 Convertible securities. Under section 544(b) outstanding securities of a corporation such as bonds, debentures, or other corporate obligations, convertible...

  4. Treatment of dairy manure effluent using freshwater algae: algal productivity and recovery of manure nutrients using pilot-scale algal turf scrubbers.

    Science.gov (United States)

    Mulbry, Walter; Kondrad, Shannon; Pizarro, Carolina; Kebede-Westhead, Elizabeth

    2008-11-01

    Cultivating algae on nitrogen (N) and phosphorus (P) in animal manure effluents presents an alternative to the current practice of land application. The objective of this study was to determine values for productivity, nutrient content, and nutrient recovery using filamentous green algae grown in outdoor raceways at different loading rates of raw and anaerobically digested dairy manure effluent. Algal turf scrubber raceways (30m2 each) were operated in central Maryland for approximately 270 days each year (roughly April 1-December 31) from 2003 to 2006. Algal biomass was harvested every 4-12 days from the raceways after daily additions of manure effluent corresponding to loading rates of 0.3 to 2.5g total N (TN) and 0.08 to 0.42g total P (TP) m(-2)d(-1). Mean algal productivity values increased from approximately 2.5g DW m(-2)d(-1) at the lowest loading rate (0.3g TN m(-2)d(-1)) to 25g DW m(-2)d(-1) at the highest loading rate (2.5g TN m(-2)d(-1)). Mean N and P contents in the dried biomass increased 1.5-2.0-fold with increasing loading rate up to maximums of 7% N and 1% P (dry weight basis). Although variable, algal N and P accounted for roughly 70-90% of input N and P at loading rates below 1g TN, 0.15g TP m(-2)d(-1). N and P recovery rates decreased to 50-80% at higher loading rates. There were no significant differences in algal productivity, algal N and P content, or N and P recovery values from raceways with carbon dioxide supplementation compared to values from raceways without added carbon dioxide. Projected annual operational costs are very high on a per animal basis ($780 per cow). However, within the context of reducing nutrient inputs in sensitive watersheds such as the Chesapeake Bay, projected operational costs of $11 per kgN are well below the costs cited for upgrading existing water treatment plants.

  5. Swales' Cars Model and the Metaphor of Research Space: An ...

    African Journals Online (AJOL)

    ANDCORPgh changing the world

    H. Asaah, Department of French (UG); and Dr. Charles Asante, Language Centre (UG). Adika, G. S. K. / Legon ..... constructing syntax and imagery that are imprecise and opaque is that he draws his creative inspiration and ... section 3 looks at the definition of SVCs from a typological perspective whilst section 4 examines ...

  6. Efficiency and reliability improvement in wind turbine converters by grid converter adaptive control

    DEFF Research Database (Denmark)

    Trintis, Ionut; Munk-Nielsen, Stig; Abrahamsen, Flemming

    2013-01-01

    This paper presents a control method that reduces the losses in wind turbine converters adaptively controlling the grid converter. The dc-link voltage adapts its reference based on the system state and therefore reduces the stored energy, and is therefore kept at the minimum necessary for the grid...... and generator side. Operating in this way, the electrical and thermal stress factors are decreased on the power electronic devices, increasing their lifetime. The simulation results using this method show efficiency increase and devices temperature cycles slightly decreased. Experimental results on a wind...... turbine power stack shows efficiency increase in the high power region....

  7. CCLIBS: The CERN Power Converter Control Libraries

    CERN Document Server

    AUTHOR|(SzGeCERN)404953; Lebioda, Krzysztof Tomasz; Magrans De Abril, Marc; Martino, Michele; Murillo Garcia, Raul; Nicoletti, Achille

    2015-01-01

    Accurate control of power converters is a vital activity in large physics projects. Several different control scenarios may coexist, including regulation of a circuit’s voltage, current, or field strength within a magnet. Depending on the type of facility, a circuit’s reference value may be changed asynchronously or synchronously with other circuits. Synchronous changes may be on demand or under the control of a cyclic timing system. In other cases, the reference may be calculated in real-time by an outer regulation loop of some other quantity, such as the tune of the beam in a synchrotron. The power stage may be unipolar or bipolar in voltage and current. If it is unipolar in current, it may be used with a polarity switch. Depending on the design, the power stage may be controlled by a firing angle or PWM duty-cycle reference, or a voltage or current reference. All these cases are supported by the CERN Converter Control Libraries (CCLIBS). These open-source C libraries include advanced reference generati...

  8. Polarization-switching D/A converter.

    Science.gov (United States)

    Sun, Shunming; Kalkur, Thottam S

    2005-05-01

    This paper describes a novel digital-to-analog (D/A) conversion technique, which uses the analog quantity polarization as a D/A conversion medium. It can be implemented by CMOS capacitors or by ferroelectric capacitors, which exhibit strong nonlinearity in charge versus voltage behavior. Because a ferroelectric material inherently has spontaneous polarization and generally has a large dielectric constant, the effective capacitance of a ferroelectric capacitor is much larger than that of a CMOS capacitor of the same size. This ensures less influence of bottom-electrode parasitic capacitance on a ferroelectric capacitor. Furthermore, a data converter based on ferroelectric capacitors possesses the potential nonvolatile memory function owing to ferroelectric hysteresis. Along with the architecture proposed for polarization-switching digital-to-analog converter (PDAC), its circuit implementation is introduced. Described is implementation of two 9-bit bipolar PDACs: one is based on CMOS capacitors and the other on off-chip ferroelectric capacitors. Experimental results are presented for the performance of these two prototypes.

  9. Angiotensin converting enzyme 2 and atherosclerosis.

    Science.gov (United States)

    Wang, Yutang; Tikellis, Chris; Thomas, Merlin C; Golledge, Jonathan

    2013-01-01

    Angiotensin converting enzyme 2 (ACE2) is a homolog of angiotensin converting enzyme (ACE) which generates angiotensin II from angiotensin I. ACE, its product angiotensin II and the downstream angiotensin type I receptor are important components of the renin-angiotensin system (RAS). Angiotensin II, the most important component of the RAS, promotes the development of atherosclerosis. The identification of ACE2 in 2000 opened a new chapter of research on the regulation of the RAS. ACE2 degrades pro-atherosclerotic angiotensin II and generates anti-atherosclerotic angiotensin 1-7. In this review, we explored the importance of ACE2 in protecting experimental animals from developing atherosclerosis and its involvement in human atherosclerosis. We also examined the published evidence assessing the importance of ACE2 in different cell types relevant to atherosclerosis and putative underlying cellular and molecular mechanisms linking ACE2 with protection from atherosclerosis. ACE2 shifts the balance from angiotensin II to angiotensin 1-7 inhibiting the progression of atherosclerosis in animal models. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Resonant Tunneling Analog-To-Digital Converter

    Science.gov (United States)

    Broekaert, T. P. E.; Seabaugh, A. C.; Hellums, J.; Taddiken, A.; Tang, H.; Teng, J.; vanderWagt, J. P. A.

    1995-01-01

    As sampling rates continue to increase, current analog-to-digital converter (ADC) device technologies will soon reach a practical resolution limit. This limit will most profoundly effect satellite and military systems used, for example, for electronic countermeasures, electronic and signal intelligence, and phased array radar. New device and circuit concepts will be essential for continued progress. We describe a novel, folded architecture ADC which could enable a technological discontinuity in ADC performance. The converter technology is based on the integration of multiple resonant tunneling diodes (RTD) and hetero-junction transistors on an indium phosphide substrate. The RTD consists of a layered semiconductor hetero-structure AlAs/InGaAs/AlAs(2/4/2 nm) clad on either side by heavily doped InGaAs contact layers. Compact quantizers based around the RTD offer a reduction in the number of components and a reduction in the input capacitance Because the component count and capacitance scale with the number of bits N, rather than by 2 (exp n) as in the flash ADC, speed can be significantly increased, A 4-bit 2-GSps quantizer circuit is under development to evaluate the performance potential. Circuit designs for ADC conversion with a resolution of 6-bits at 25GSps may be enabled by the resonant tunneling approach.

  11. Converting DYNAMO simulations to Powersim Studio simulations

    Energy Technology Data Exchange (ETDEWEB)

    Walker, La Tonya Nicole; Malczynski, Leonard A.

    2014-02-01

    DYNAMO is a computer program for building and running 'continuous' simulation models. It was developed by the Industrial Dynamics Group at the Massachusetts Institute of Technology for simulating dynamic feedback models of business, economic, and social systems. The history of the system dynamics method since 1957 includes many classic models built in DYANMO. It was not until the late 1980s that software was built to take advantage of the rise of personal computers and graphical user interfaces that DYNAMO was supplanted. There is much learning and insight to be gained from examining the DYANMO models and their accompanying research papers. We believe that it is a worthwhile exercise to convert DYNAMO models to more recent software packages. We have made an attempt to make it easier to turn these models into a more current system dynamics software language, Powersim © Studio produced by Powersim AS2 of Bergen, Norway. This guide shows how to convert DYNAMO syntax into Studio syntax.

  12. Comparison of single-phase matrix converter and H-bridge converter for radio frequency induction heating

    OpenAIRE

    Nguyen-Quang, N.; Stone, D. A.; Bingham, Chris; Foster, M. P.

    2007-01-01

    This paper compares the newly developed single-phase matrix converter and the more conventional H- bridge converter for radio frequency induction heating. Both the converters exhibit unity power factor, very low total harmonic distortion at the utility supply interface, good controllability under soft switching condition for a wide range of power, and high efficiencies, whilst still having simple structures. A novel switching control pattern has been proposed for the matrix converter in order...

  13. Two phase interleaved buck converter for driving high power LEDs

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2011-01-01

    The goal of this paper is to evaluate an interleaved buck topology for driving high current light-emitting diodes. Low output capacitor value allows the use of non-electrolytic capacitors extending the lifetime of the converter. Converter is operated as a constant, regulated current source which ...... be operated close to the 50% duty cycle, where the ripple attenuation is the highest....... increases luminous efficacy of LED compared to PWM dimmed system. Because of the low dynamic resistance of LEDs the duty cycle of the converter does not change greatly with controlled current. By setting the input voltage of the buck converter to around twice the voltage of diode strings, converter can...

  14. Three new DC-to-DC Single-Switch Converters

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2017-06-01

    Full Text Available This paper presents a new family of three previously unidentified dc-to-dc converters, buck, boost, and buck-boost voltage-transfer-function topologies, which offer advantageous transformer coupling features and low capacitor dc voltage stressing. The three single-switch, single-diode, converters offer the same features as basic dc-to-dc converters, such as the buck function with continuous output current and the boost function with continuous input current. Converter time-domain simulations and experimental results (including transformer coupling support and extol the dc-to-dc converter concepts and analysis presented.

  15. A novel unipolar converter for switched reluctance motor

    Science.gov (United States)

    Le-Huy, Hoang; Viarouge, Philippe; Francoeur, Bruno

    1990-10-01

    A configuration of a unipolar converter with improved switching performance suitable for switched-reluctance motor supply is presented. The switched-reluctance motor operation principle is presented, and its ideal characteristics are considered. The proposed converter is described, and its operation is analyzed. The converter characteristics are studied with the aid of computer simulation. Current control of the proposed converter is considered. A prototype converter has been built to verify the analysis results and to validate the simulation. The design procedure is presented, and experimental results which confirm the analysis are given and discussed.

  16. Direct Sensitivity Analysis of the DC-to-DC Converters

    Directory of Open Access Journals (Sweden)

    Elena Niculescu

    2009-05-01

    Full Text Available The mathematical principle of the directsensitivity analysis of the dynamic systems and itsapplication to the DC-to-DC PWM converters arepresented. The model of the dynamic system associatedto the PWM Sepic converter with parasitic includedand continuous conduction mode (CCM, and coupledinductors was used in this study. The modelling of theconverter and the state sensitivity analysis with respectto some parameters of the converter have beenperformed with MATLAB environment. The algorithmcarried out for computing the state sensitivity functionsof converter can be applied to other configurations ofDC-to-DC PWM converters, for the two operatingmodes (CCM and DCM, with parasitic included andwith coupled or separate inductors, regardless ofsystem order.

  17. Comparative Analysis of Resonant Converters for Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Vuchev Stoyan

    2017-01-01

    Full Text Available The following paperwork presents a comparative analysis of multiphase resonant converters for applications in energy storage systems. Models of the examined converters are developed in the software environments of MATLAB and LTspice. Results from the simulation examination of the converters during charging of supercapacitors and rechargeable batteries are presented. These results are compared to results obtained from experimental examination of the converters via a laboratory stand. For the purposes of the experimental examination, a control system is developed on the base of a virtual instrument in LabVIEW. The advantages and disadvantages of the different converters are discussed.

  18. Evaluation of permeable friction course (PFC), roadside filter strips, dry swales, and wetland swales for treatment of highway stormwater runoff.

    Science.gov (United States)

    2011-01-07

    Stormwater runoff from roadways is a source of surface water pollution in North Carolina. The North Carolina Department of Transportation (NCDOT) is required to implement stormwater control measures (SCMs) in the linear environment. NCDOT has specifi...

  19. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    . A detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance. • If optimally designed, boost converters......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, if a converter is properly designed, primary side voltage clamp circuits will not even work in low voltage high power converters. • Very high conversion efficiency can be achieved. Peak efficiency of 98% and worst case minimum efficiency of 96.8% are demonstrated on a 1.5 kW converter. The ability...

  20. Benefits and Drawbacks of A High Frequency Gan Zvzcps Converter

    Directory of Open Access Journals (Sweden)

    Blanes J. M.

    2017-01-01

    Full Text Available This paper presents the benefits and drawbacks of replacing the traditional Si Mosfets transistors with enhancement mode GaN transistors in a Half-Bridge Zero Voltage and Zero Current Switching Power Switching (ZVZCPS converter. This type of converters is usually used as Electronic Power Converters (EPC for telecommunication satellites travelling-wave tube amplifiers (TWTAs. In this study, firstly the converter is theoretically analysed, obtaining its operation, losses and efficiency equations. From these equations, optimizations maps based on the main system parameters are obtained. These optimization maps are the key to quantify the potential benefits of GaN transistors in this type of converters. Theoretical results show that using GaN transistors, the frequency of the converter can be pushed from 125kHz to 830kHz without sacrificing the converter efficiency. This frequency increase is directly related to reduction on the EPC size and weight.

  1. Converter applications and their influence on large electrical machines

    CERN Document Server

    Drubel, Oliver

    2013-01-01

    Converter driven applications are applied in more and more processes. Almost any installed wind-farm, ship drives, steel mills, several boiler feed water pumps, extruder and many other applications operate much more efficient and economic in case of variable speed solutions. The boundary conditions for a motor or generator will change, if it is supplied by a converter. An electrical machine, which is operated by a converter, can no longer be regarded as an independent component, but is embedded in a system consisting of converter and machine. This book gives an overview of existing converter designs for large electrical machines. Methods for the appropriate calculation of machine phenomena, which are implied by converters are derived in the power range above 500kVA. It is shown how due to the converter inherent higher voltage harmonics and pulse frequencies special phenomena are caused inside the machine which can be the reason for malfunction. It is demonstrated that additional losses create additional tempe...

  2. Passive components used in power converters

    CERN Document Server

    Rufer, A; Barrade, P

    2006-01-01

    In power converters, passive components play an important role, and have in general specific nature and properties. The goal of this tutorial is to give an overview, first on inductive components for power conversion, and second on dedicated power capacitors. In a third part, new components— supercapacitors—will be presented. Generally, inductors for power applications must be custom designed. In this tutorial, the most important effects encountered when realising inductive components will be presented in the first part, without entering into the detailed design of such components. For that purpose, the referenced documents that have served as a base for this tutorial must be consulted [1], [2], and mainly [3]. The second part of this tutorial (Capacitors used in power electronics) is dedicated to power capacitors. Unlike inductors, capacitors cannot be specifically designed, but must be selected from a manufacturer’s list of components. Here, the documentation corresponds to a subset of Ref. [4] that h...

  3. DC-to-DC switching converter

    Science.gov (United States)

    Cuk, Slobodan M. (Inventor); Middlebrook, Robert D. (Inventor)

    1980-01-01

    A dc-to-dc converter having nonpulsating input and output current uses two inductances, one in series with the input source, the other in series with the output load. An electrical energy transferring device with storage, namely storage capacitance, is used with suitable switching means between the inductances to DC level conversion. For isolation between the source and load, the capacitance may be divided into two capacitors coupled by a transformer, and for reducing ripple, the inductances may be coupled. With proper design of the coupling between the inductances, the current ripple can be reduced to zero at either the input or the output, or the reduction achievable in that way may be divided between the input and output.

  4. Converting energy from fusion into useful forms

    CERN Document Server

    Kovari, M; Jenkins, I; Kiely, C

    2014-01-01

    If fusion power reactors are to be feasible, it will still be necessary to convert the energy of the nuclear reaction into usable form. The heat produced will be removed from the reactor core by a primary coolant, which might be water, helium, molten lithium-lead, molten lithium-containing salt, or CO2. The heat could then be transferred to a conventional Rankine cycle or Brayton (gas turbine) cycle. Alternatively it could be used for thermochemical processes such as producing hydrogen or other transport fuels. Fusion presents new problems because of the high energy neutrons released. These affect the selection of materials and the operating temperature, ultimately determining the choice of coolant and working cycle. The limited temperature ranges allowed by present day irradiated structural materials, combined with the large internal power demand of the plant, will limit the overall thermal efficiency. The operating conditions of the fusion power source, the materials, coolant, and energy conversion system w...

  5. Mechanical vibration to electrical energy converter

    Science.gov (United States)

    Kellogg, Rick Allen [Tijeras, NM; Brotz, Jay Kristoffer [Albuquerque, NM

    2009-03-03

    Electromechanical devices that generate an electrical signal in response to an external source of mechanical vibrations can operate as a sensor of vibrations and as an energy harvester for converting mechanical vibration to electrical energy. The devices incorporate a magnet that is movable through a gap in a ferromagnetic circuit, wherein a coil is wound around a portion of the ferromagnetic circuit. A flexible coupling is used to attach the magnet to a frame for providing alignment of the magnet as it moves or oscillates through the gap in the ferromagnetic circuit. The motion of the magnet can be constrained to occur within a substantially linear range of magnetostatic force that develops due to the motion of the magnet. The devices can have ferromagnetic circuits with multiple arms, an array of magnets having alternating polarity and, encompass micro-electromechanical (MEM) devices.

  6. A system for converting print into braille.

    Science.gov (United States)

    Blenkhorn, P

    1997-06-01

    This paper describes a method for converting text into braille, in the form in which it is stored as in a computer. The system has been designed to be configurable for a wide range of languages and character sets, and uses a predominantly table driven method to achieve this. The algorithm is explained in the context of the conversion of text into Standard English Braille (British), and the tables for this transformation are given. Particular importance has been attached to enabling braille specialists, who are not experts in computer algorithms, to be able to modify the system for either slight modifications to an existing braille code translator, or for producing a braille code translator for a new language.

  7. Generators for gearless wind energy converters

    Energy Technology Data Exchange (ETDEWEB)

    Grauers, A. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1996-12-01

    This paper discusses some design alternatives for directly driven generators, and one specific generator type is investigated for a wide range of rated power. First, the specification for a directly driven generator is presented, then different design alternatives are discussed. A radial-flux permanent magnet generator for frequency converter connection has been chosen for a more detailed investigation. The design, optimization and performance of that generator type are presented. Generators from 30 kW to 3 MW are designed and compared with conventional four-pole generators with gear. It is found that a directly driven generator can be more efficient than a conventional generator and gear and have a rather small diameter and a low active weight. 8 refs, 7 figs, 2 tabs

  8. Modular Multilevel Converters: Control and Applications

    Directory of Open Access Journals (Sweden)

    Fernando Martinez-Rodrigo

    2017-10-01

    Full Text Available This review article is mainly oriented to the control and applications of modular multilevel converters (MMC. The main topologies of the switching modules are presented, for normal operation and for the elimination of DC faults. Methods to keep the capacitor voltage balanced are included. The voltage and current modulators, that are the most internal loops of control, are detailed. Voltage control and current control schemes are included which regulate DC link voltage and reactive power. The cases of unbalanced and distorted networks are analyzed, and schemes are proposed so that MMC contribute to improve the quality of the grid in these situations. The main applications in high voltage direct current (HVDC transmission along with other medium voltage (MV and low voltage (LV applications are included. Finally, the application to offshore wind farms is specifically analyzed.

  9. Pseudomonas spp. convert metmyoglobin into deoxymyoglobin.

    Science.gov (United States)

    Motoyama, Michiyo; Kobayashi, Miho; Sasaki, Keisuke; Nomura, Masaru; Mitsumoto, Mitsuru

    2010-01-01

    Meat 'reddening' by bacteria was observed in chilled beef. To identify the reddening bacteria, isolates were inoculated onto beef and the changes in CIE L*a*b* values monitored. As a result, two Pseudomonas spp., including Pseudomonas fragi which is commonly observed in raw meat, were selected and identified as reddening bacteria. The reddening was coincidentally occurred with the appearance of slime, and the increase in thiobarbituric acid-reactive substances (TBARS) was simultaneously suppressed. In myoglobin-containing nutrient broth, it is shown spectroscopically that P. fragi converted metmyoglobin into deoxymyoglobin. It was concluded that the meat reddening was due to the formation of deoxymyoglobin, induced by the very-low-oxygen tension brought about by Pseudomonad's oxygen consumption: This oxygen depletion simultaneously suppressed TBARS increase.

  10. Power Generation Using Mechanical Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Srinivasan Chandrasekaran

    2012-03-01

    Full Text Available Ocean wave energy plays a significant role in meeting the growing demand of electric power. Economic, environmental, and technical advantages of wave energy set it apart from other renewable energy resources. Present study describes a newly proposed Mechanical Wave Energy Converter (MEWC that is employed to harness heave motion of floating buoy to generate power. Focus is on the conceptual development of the device, illustrating details of component level analysis. Employed methodology has many advantages such as i simple and easy fabrication; ii easy to control the operations during rough weather; and iii low failure rate during normal sea conditions. Experimental investigations carried out on the scaled model of MWEC show better performance and its capability to generate power at higher efficiency in regular wave fields. Design Failure Mode and Effect Analysis (FMEA shows rare failure rates for all components except the floating buoy.

  11. Layout Optimisation of Wave Energy Converter Arrays

    Directory of Open Access Journals (Sweden)

    Pau Mercadé Ruiz

    2017-08-01

    Full Text Available This paper proposes an optimisation strategy for the layout design of wave energy converter (WEC arrays. Optimal layouts are sought so as to maximise the absorbed power given a minimum q-factor, the minimum distance between WECs, and an area of deployment. To guarantee an efficient optimisation, a four-parameter layout description is proposed. Three different optimisation algorithms are further compared in terms of performance and computational cost. These are the covariance matrix adaptation evolution strategy (CMA, a genetic algorithm (GA and the glowworm swarm optimisation (GSO algorithm. The results show slightly higher performances for the latter two algorithms; however, the first turns out to be significantly less computationally demanding.

  12. Will oscillating wave surge converters survive tsunamis?

    Directory of Open Access Journals (Sweden)

    L. O’Brien

    2015-07-01

    Full Text Available With an increasing emphasis on renewable energy resources, wave power technology is becoming one of the realistic solutions. However, the 2011 tsunami in Japan was a harsh reminder of the ferocity of the ocean. It is known that tsunamis are nearly undetectable in the open ocean but as the wave approaches the shore its energy is compressed, creating large destructive waves. The question posed here is whether an oscillating wave surge converter (OWSC could withstand the force of an incoming tsunami. Several tools are used to provide an answer: an analytical 3D model developed within the framework of linear theory, a numerical model based on the non-linear shallow water equations and empirical formulas. Numerical results show that run-up and draw-down can be amplified under some circumstances, leading to an OWSC lying on dry ground!

  13. Hybrid-free Josephson Parametric Converter

    Science.gov (United States)

    Frattini, N. E.; Narla, A.; Sliwa, K. M.; Shankar, S.; Hatridge, M.; Devoret, M. H.

    A necessary component for any quantum computation architecture is the ability to perform efficient quantum operations. In the microwave regime of superconducting qubits, these quantum-limited operations can be realized with a non-degenerate Josephson junction based three-wave mixer, the Josephson Parametric Converter (JPC). Currently, the quantum signal of interest must pass through a lossy 180 degree hybrid to be presented as a differential drive to the JPC. This hybrid therefore places a limit on the quantum efficiency of the system and also increases the device footprint. We present a new design for the JPC eliminating the need for any external hybrid. We also show that this design has nominally identical performance to the conventional JPC. Work supported by ARO, AFOSR and YINQE.

  14. Simplifying the circuit of Josephson parametric converters

    Science.gov (United States)

    Abdo, Baleegh; Brink, Markus; Chavez-Garcia, Jose; Keefe, George

    Josephson parametric converters (JPCs) are quantum-limited three-wave mixing devices that can play various important roles in quantum information processing in the microwave domain, including amplification of quantum signals, transduction of quantum information, remote entanglement of qubits, nonreciprocal amplification, and circulation of signals. However, the input-output and biasing circuit of a state-of-the-art JPC consists of bulky components, i.e. two commercial off-chip broadband 180-degree hybrids, four phase-matched short coax cables, and one superconducting magnetic coil. Such bulky hardware significantly hinders the integration of JPCs in scalable quantum computing architectures. In my talk, I will present ideas on how to simplify the JPC circuit and show preliminary experimental results

  15. Clustering of cycloidal wave energy converters

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Stefan G.

    2016-03-29

    A wave energy conversion system uses a pair of wave energy converters (WECs) on respective active mountings on a floating platform, so that the separation of the WECs from each other or from a central WEC can be actively adjusted according to the wavelength of incident waves. The adjustable separation facilitates operation of the system to cancel reactive forces, which may be generated during wave energy conversion. Modules on which such pairs of WECs are mounted can be assembled with one or more central WECs to form large clusters in which reactive forces and torques can be made to cancel. WECs of different sizes can be employed to facilitate cancelation of reactive forces and torques.

  16. High-power converters for space applications

    Science.gov (United States)

    Park, J. N.; Cooper, Randy

    1991-06-01

    Phase 1 was a concept definition effort to extend space-type dc/dc converter technology to the megawatt level with a weight of less than 0.1 kg/kW (220 lb./MW). Two system designs were evaluated in Phase 1. Each design operates from a 5 kV stacked fuel cell source and provides a voltage step-up to 100 kV at 10 A for charging capacitors (100 pps at a duty cycle of 17 min on, 17 min off). Both designs use an MCT-based, full-bridge inverter, gaseous hydrogen cooling, and crowbar fault protection. The GE-CRD system uses an advanced high-voltage transformer/rectifier filter is series with a resonant tank circuit, driven by an inverter operating at 20 to 50 kHz. Output voltage is controlled through frequency and phase shift control. Fast transient response and stability is ensured via optimal control. Super-resonant operation employing MCTs provides the advantages of lossless snubbing, no turn-on switching loss, use of medium-speed diodes, and intrinsic current limiting under load-fault conditions. Estimated weight of the GE-CRD system is 88 kg (1.5 cu ft.). Efficiency of 94.4 percent and total system loss is 55.711 kW operating at 1 MW load power. The Maxwell system is based on a resonance transformer approach using a cascade of five LC resonant sections at 100 kHz. The 5 kV bus is converted to a square wave, stepped-up to a 100 kV sine wave by the LC sections, rectified, and filtered. Output voltage is controlled with a special series regulator circuit. Estimated weight of the Maxwell system is 83.8 kg (4.0 cu ft.). Efficiency is 87.2 percent and total system loss is 146.411 kW operating at 1 MW load power.

  17. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  18. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    and maximum output power. In chapter 3, a detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based....... • If optimally designed, boost converters will be much more efficient than comparable buck type converters for high power low voltage applications. • The use of voltage clamp circuits to protect primary switches in boost converters is no longer needed for device protection. On the other hand...

  19. High Voltage Bi-directional Flyback Converter for Capacitive Actuator

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    This paper presents a high voltage DC-DC converter topology for bi-directional energy transfer between a low voltage DC source and a high voltage capacitive load. The topology is a bi-directional flyback converter with variable switching frequency control during the charge mode, and constant...... switching frequency control during the discharge mode. The converter is capable of charging the capacitive load from 24 V DC source to 2.5 kV, and discharges it to 0 V. The flyback converter has been analyzed in detail during both charge and discharge modes, by considering all the parasitic elements...... in the converter, including the most dominating parameters of the high voltage transformer viz., self-capacitance and leakage inductance. The specific capacitive load for this converter is a dielectric electro active polymer (DEAP) actuator, which can be used as an effective replacement for conventional actuators...

  20. Design of converter topology for switched reluctance wind power generator

    Science.gov (United States)

    Dong, Lei; Liu, Yiyi; Ling, Lulu; Liao, Xiaozhong; Wang, Zhe

    2017-05-01

    Considering the small output power of switched reluctance generator (SRG) at low speed, this paper proposes a new power converter topology based on the operation principle of switched reluctance generator, aiming to improve the performance of traditional power converter. The new power converter includes two working modes: full winding excitation power generation and partial winding excitation power generation, which are applied to different speed to increase the output power. To verify the feasibility of proposed converter, simulations and experiments on the SRG with single phase, external rotor, and U-shaped stators are conducted, compared with the traditional power converter. The simulation results show that the new power converter increases the output power and improve the efficiency of SRG at low speed.

  1. Grid Converters for Stationary Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Trintis, Ionut

    to hours, rated at MW and MWh, battery energy storage systems are suitable and ecient solutions. Grid connection of the storage system can be done at dierent voltage levels, depending on the location and application scenario. For high power and energy ratings, increase in the battery and converter voltage...... was realized for a 100 kW active rectier to be used in a 6 kV battery energy storage test bench. In the second part, dierent solutions for power converters to interface energy storage units to medium voltage grid are given. A new modular multilevel converter concept is introduced, where the energy storage......-voltage 100 kW bidirectional grid converter, to be used in a high voltage battery energy storage test bench. The control structure proved to be stable without damping. The converter was tested in the test bench and the experimental results are presented. Multilevel converters are replacing the classical two...

  2. RISK ANALYSIS FOR SHIP CONVERTING PROJECT ACCOMPLISHMENT (Case study of KRI KP Converting Project

    Directory of Open Access Journals (Sweden)

    Dimas Endro W

    2013-10-01

    Full Text Available Ship converting has become as prospective activity in ship building area. Operational and economical aspect are the most dominant rationale. Baseon a new fuction of converted ship, a task list which contain several jobs that must be done is listed. This accomplishment schedule not only contain a task list, but also duration for certain job title. In practical apllication job duration is maintained based on experience of project manager.  Further more, total accomplish duration is setted as time accomplishment for the project. This setted time has become reference for the project bid. Occasionaly, if accomplishment time which offered is strict, than schedule slip become as potencial nightmare. For this situation, project manager has had a cristal clearconsideration to select a proper decision wheter he will take the tender offer or not. practically, project mananger has layed on his experience to handle previous project and face  penalty if the project delayed. This paper focussed on how to measure tender offer based on risk analysis, specially for converted ship tender which has a strike time accomplishment.A new application method to analysis proposed tender based on time and penalty parameter has become a topic of this paper.

  3. Grid Connected Solar PV System with SEPIC Converter Compared with Parallel Boost Converter Based MPPT

    Directory of Open Access Journals (Sweden)

    T. Ajith Bosco Raj

    2014-01-01

    Full Text Available The main objective of this work is to study the behaviour of the solar PV systems and model the efficient Grid-connected solar power system. The DC-DC MPPT circuit using chaotic pulse width modulation has been designed to track maximum power from solar PV module. The conversion efficiency of the proposed MPPT system is increased when CPWM is used as a control scheme. This paper also proposes a simplified multilevel (seven level inverter for a grid-connected photovoltaic system. The primary goal of these systems is to increase the energy injected to the grid by keeping track of the maximum power point of the panel, by reducing the switching frequency, and by providing high reliability. The maximum power has been tracked experimentally. It is compared with parallel boost converter. Also this model is based on mathematical equations and is described through an equivalent circuit including a PV source with MPPT, a diode, a series resistor, a shunt resistor, and dual boost converter with active snubber circuit. This model can extract PV power and boost by using dual boost converter with active snubber. By using this method the overall system efficiency is improved thereby reducing the switching losses and cost.

  4. Damping Profile Research for Corpower Ocean's Wave Energy Converter

    OpenAIRE

    Zhou, Tianzhi

    2016-01-01

    With increasing energy demanding and greenhouse gases from fossil fuel, the need to develop new ways to convert energy in sustainable methods is becoming more and more urgent. Corpower Ocean AB designed a point absorber type wave energy converter to harvest energy from surface wave. To maximize the energy output, phase and amplitude control of the converter are needed. Falnes and Budal proposed latching around 1980s which could deliver almost perfect phase and thusly boost power output, howev...

  5. A Three-level 4 x 3 Conventinal Matrix Converter

    DEFF Research Database (Denmark)

    Rong, Runjie; Loh, Poh Chiang; Wang, Peter

    2007-01-01

    This paper proposes a topology of a three-level 4 × 3 conventional matrix converter with 12 bi-directional switches. PWM control and modulation index compensation have been investigated. Operation theory has been verified by the simulation results using Matlab. The simulation results show...... that the switching output performance of the proposed matrix converter is more efficient than that of existing matrix converters....

  6. Optimizing design of converters using power cycling lifetime models

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup; Munk-Nielsen, Stig

    2015-01-01

    Converter power cycling lifetime depends heavily on converter operation point. A lifetime model of a single power module switched mode power supply with wide input voltage range is shown. A lifetime model is created using a power loss model, a thermal model and a model for power cycling capability...... with a given mission profile. A method to improve the expected lifetime of the converter is presented, taking into account switching frequency, input voltage and transformer turns ratio....

  7. Power factor improvement using DCM Cuk converter with coupled inductor

    OpenAIRE

    Ranganathan, G; Umanand, L

    1999-01-01

    Most of the power factor regulator topologies in continuous conduction mode result in bulky magnetics, and in discontinuous conduction mode result in high harmonic content. To solve these problems a Cuk topology is presented in discontinuous conduction mode (DCM) with coupled inductors for power factor regulation, the unique feature exhibited by the converter that makes the converter better than the other converter in DCM operation for power factor regulation. Inductive coupling is used to tr...

  8. Novel Modulation Method for Multidirectional Matrix Converter

    Directory of Open Access Journals (Sweden)

    Saman Toosi

    2014-01-01

    Full Text Available This study presents a new modulation method for multidirectional matrix converter (MDMC, based on the direct duty ratio pulse width modulation (DDPWM. In this study, a new structure of MDMC has been proposed to control the power flow direction through the stand-alone battery based system and hybrid vehicle. The modulation method acts based on the average voltage over one switching period concept. Therefore, in order to determine the duty ratio for each switch, the instantaneous input voltages are captured and compared with triangular waveform continuously. By selecting the proper switching pattern and changing the slope of the carriers, the sinusoidal input current can be synthesized with high power factor and desired output voltage. The proposed system increases the discharging time of the battery by injecting the power to the system from the generator and battery at the same time. Thus, it makes the battery life longer and saves more energy. This paper also derived necessary equation for proposed modulation method as well as detail of analysis and modulation algorithm. The theoretical and modulation concepts presented have been verified in MATLAB simulation.

  9. Novel modulation method for multidirectional matrix converter.

    Science.gov (United States)

    Toosi, Saman; Misron, Norhisam; Hanamoto, Tsuyoshi; Bin Aris, Ishak; Radzi, Mohd Amran Mohd; Yamada, Hiroaki

    2014-01-01

    This study presents a new modulation method for multidirectional matrix converter (MDMC), based on the direct duty ratio pulse width modulation (DDPWM). In this study, a new structure of MDMC has been proposed to control the power flow direction through the stand-alone battery based system and hybrid vehicle. The modulation method acts based on the average voltage over one switching period concept. Therefore, in order to determine the duty ratio for each switch, the instantaneous input voltages are captured and compared with triangular waveform continuously. By selecting the proper switching pattern and changing the slope of the carriers, the sinusoidal input current can be synthesized with high power factor and desired output voltage. The proposed system increases the discharging time of the battery by injecting the power to the system from the generator and battery at the same time. Thus, it makes the battery life longer and saves more energy. This paper also derived necessary equation for proposed modulation method as well as detail of analysis and modulation algorithm. The theoretical and modulation concepts presented have been verified in MATLAB simulation.

  10. Image processing to optimize wave energy converters

    Science.gov (United States)

    Bailey, Kyle Marc-Anthony

    The world is turning to renewable energies as a means of ensuring the planet's future and well-being. There have been a few attempts in the past to utilize wave power as a means of generating electricity through the use of Wave Energy Converters (WEC), but only recently are they becoming a focal point in the renewable energy field. Over the past few years there has been a global drive to advance the efficiency of WEC. Placing a mechanical device either onshore or offshore that captures the energy within ocean surface waves to drive a mechanical device is how wave power is produced. This paper seeks to provide a novel and innovative way to estimate ocean wave frequency through the use of image processing. This will be achieved by applying a complex modulated lapped orthogonal transform filter bank to satellite images of ocean waves. The complex modulated lapped orthogonal transform filterbank provides an equal subband decomposition of the Nyquist bounded discrete time Fourier Transform spectrum. The maximum energy of the 2D complex modulated lapped transform subband is used to determine the horizontal and vertical frequency, which subsequently can be used to determine the wave frequency in the direction of the WEC by a simple trigonometric scaling. The robustness of the proposed method is provided by the applications to simulated and real satellite images where the frequency is known.

  11. Structural Loads Analysis for Wave Energy Converters

    Energy Technology Data Exchange (ETDEWEB)

    van Rij, Jennifer A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Yu, Yi-Hsiang [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Guo, Yi [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-03

    This study explores and verifies the generalized body-modes method for evaluating the structural loads on a wave energy converter (WEC). Historically, WEC design methodologies have focused primarily on accurately evaluating hydrodynamic loads, while methodologies for evaluating structural loads have yet to be fully considered and incorporated into the WEC design process. As wave energy technologies continue to advance, however, it has become increasingly evident that an accurate evaluation of the structural loads will enable an optimized structural design, as well as the potential utilization of composites and flexible materials, and hence reduce WEC costs. Although there are many computational fluid dynamics, structural analyses and fluid-structure-interaction (FSI) codes available, the application of these codes is typically too computationally intensive to be practical in the early stages of the WEC design process. The generalized body-modes method, however, is a reduced order, linearized, frequency-domain FSI approach, performed in conjunction with the linear hydrodynamic analysis, with computation times that could realistically be incorporated into the WEC design process.

  12. A SOFT SWITCHED INTERLEAVED HIGH GAIN DC-DC CONVERTER

    Directory of Open Access Journals (Sweden)

    SHESHIDHAR REDDY ADDULA

    2017-09-01

    Full Text Available In this paper, a novel soft-switched interleaved DC-DC converter which provides a high voltage gain of 12 is proposed. Voltage gain of the basic interleaved boost converter is extended by using diode-capacitor multiplier (DCM cells. The switches are operated at a nominal duty ratio of 0.5. The voltage stress on the power switches and diodes is only a fraction of the output voltage. To enhance the operating power conversion efficiency, the switches are turned ON at zero voltage condition. Experimental results of 18-216V, 100W prototype converter validate the operating principle and the advantageous features of the presented converter.

  13. Analysis and Design of Embedded Controlled Parallel Resonant Converter

    Directory of Open Access Journals (Sweden)

    P. CHANDRASEKHAR

    2009-07-01

    Full Text Available Microcontroller based constant frequency controlled full bridge LC parallel resonant converter is presented in this paper for electrolyser application. An electrolyser is a part of renewable energy system which generates hydrogen from water electrolysis. The DC power required by the electrolyser system is supplied by the DC-DC converter. Owing to operation under constant frequency, the filter designs are simplified and utilization of magnetic components is improved. This converter has advantages like high power density, low EMI and reduced switching stresses. DC-DC converter system is simulated using MATLAB, Simulink. Detailed simulation results are presented. The simulation results are compared with the experimental results.

  14. Distributed Generation using Indirect Matrix Converter in Boost Operating Mode

    DEFF Research Database (Denmark)

    Liu, Xiong; Loh, Poh Chiang; Wang, Peng

    2011-01-01

    Indirect matrix converter (IMC) using two stages configuration is an interesting alternative for ac/ac conversions. In some cases, the ac/ac converter needs boost function, which can't be achieved by traditional IMC due to its limited input-to-output voltage transfer gain 0.866. Alternatively...... power factor and controllable grid-side power factor. In isolated mode, the matrix converter is controlled to supply a three-phase ac voltage and also guarantee sinusoidal input/output waveforms as well as unity input power factor. Simulation and experimental results are provided to validate...... the effectiveness of the control schemes for the proposed matrix converter....

  15. ZVZCS PWM DC-DC Converter with Energy Recovery Clamp

    Directory of Open Access Journals (Sweden)

    Jaroslav Durdik

    2008-01-01

    Full Text Available This paper presents research motivated by industrial demand for special traction drive topology devoted tominimization of traction transformer weight against topology with classical 50Hz traction transformer. The special tractiondrive topology for AC power systems consists of input high voltage trolley converter (single phase matrix converter –middle frequency transformer – output converter - traction motor has been described. The main attention has been given tothe control algorithm of the traction topology (inserting of NULL vector of matrix converter and Two-value control ofsecondary active rectifier.

  16. Integrating data converters for picoampere currents from electrochemical transducers

    DEFF Research Database (Denmark)

    Breten, Madalina; Lehmann, Torsten; Bruun, Erik

    2000-01-01

    This paper describes a current mode A/D converter designed for a maximum input current range of 5 nA and a resolution of the order of 1 pA. The converter is designed for a potentiostat for amperometric chemical sensors and provides a constant polarization voltage for the measuring electrode....... A prototype chip using the dual slope conversion method has been fabricated in a 0.7 μm CMOS process. Experimental results from this converter are reported. Design problems and limitations of the converter are discussed and a new conversion technique providing a larger dynamic range and easy calibration...

  17. High Voltage Power Converter for Large Wind Turbine

    DEFF Research Database (Denmark)

    Sztykiel, Michal

    system operates at 20 kV level - identical as for the collector distribution network. Medium voltage operation allows the converter unit along with the filter to be installed on the base platform inside the tower. In this manner, more space in the nacelle can be flexibly accommodated by the mechanical...... application. System B consists of the generator-side 2-level converter, DC/DC boost unit and a grid-side NPC-3L converter. System C is made of a seriesconnected full-bridge cells on the generator-side, and a grid-side NPC-5L converter. The performance of the proposed topologies is analyzed both under...

  18. Novel vortex generator and mode converter for electron beams.

    Science.gov (United States)

    Schattschneider, P; Stöger-Pollach, M; Verbeeck, J

    2012-08-24

    A mode converter for electron vortex beams is described. Numerical simulations, confirmed by experiment, show that the converter transforms a vortex beam with a topological charge m=±1 into beams closely resembling Hermite-Gaussian HG(10) and HG(01) modes. The converter can be used as a mode discriminator or filter for electron vortex beams. Combining the converter with a phase plate turns a plane wave into modes with topological charge m=±1. This combination serves as a generator of electron vortex beams of high brilliance.

  19. VVCF AC-AC Converters Using Single Bridge Circuit

    Science.gov (United States)

    Neba, Yasuhiko; Matsumoto, Hirokazu; Itoh, Ryozo; Ishizaka, Kouichi

    Single-phase and three-phase voltage source converters with variable voltage and constant frequency ac-ac conversion are presented. These converters are a single bridge circuit of two legs for single-phase conversion and of three legs for three-phase, respectively. Both the power source and the load are connected to bridge legs. The normal PWM methods with the sinusoidal modulating and the triangular carrier waves are used for the converters. The experimental results confirm that the PWM converters can generate the sinusoidal input/output currents.

  20. High Efficiency Hall Thruster Discharge Power Converter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Busek leveraged previous, internally sponsored, high power, Hall thruster discharge converter development which allowed it to design, build, and test new printed...

  1. Quantum Dot Spectrum Converters for Enhanced High Efficiency Photovoltaics Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This research proposes to enhance solar cell efficiency, radiation resistance and affordability. The Quantum Dot Spectrum Converter (QDSC) disperses quantum dots...

  2. Effect of hydrogel and different types of fertilizers on the number of turf shoots in lawns created by monocultures of red fescue (Festuca rubra L. cultivars and its mixtures

    Directory of Open Access Journals (Sweden)

    Kazimierz Jankowski

    2012-12-01

    Full Text Available In order to determine the effect of the hydrogel content in the soil substrate on the number of shoots per unit area of grass lawns with different proportions of red fescue and monoculture turf produced from the following fescue cultivars: Adio, Libano, Corail, Simone. In the period 2003-2004, a field experiment was carried out in a randomized block design in four replications. In combination with a hydrogel (Aqua-Gel P4, 0.05 kg x m-2 of sorbent was placed at a depth of 10 cm below the soil surface in 2002. Another experimental factor was the type of fertilizer. Trawovit (a fertilizer with standard effects and Sierrablen (a controlled-release fertilizer were used for this purpose. The quantities of fertilizer and time of fertilization date followed manufacturer's instructions. The number of shoots per 1 m2 was determined at the end of the growing season. The study showed that, regardless of years of cultivation, the type of soil substrate and fertilizer, the average number of shoots for the mixtures was about 32% lower than for monoculture lawns. The presence of the hydrogel in the soil substrate regulated soil moisture, and therefore in the mixture lawns the values of the tested features were significantly higher in the treatments with hydrogel. Fertilization with Trawovit, regardless of the type of soil substrate (H, BH, does not lead to a statistically significant difference in the number of shoots between the studied mixtures. However, in the treatments fertilized with Sierrablen, the presence of the hydrogel in the soil substrate caused a significant increase in the traits examined for the mixtures containing, respectively, 20 and 80% of red fescue in their composition. The addition of Aqua-Gel P4 to the soil substrate, when the turf lawns were fertilized with Trawovit, resulted in a significant increase in the number of shoots for the cultivars Adio, Libano and Corail.

  3. Development of a wind converter and investigation of its operational function. Part 1: Technical description of the wind energy converter

    Science.gov (United States)

    Molly, J. P.; Steinheber, R.

    1982-11-01

    A 10 kW wind energy converter was developed by using as far possible standard serial production parts. The design criteria and the description of the essential machinery components of the MODA 10 wind energy converter are discussed. For some special load cases the safety calculation of the important components is shown. The blade control system which qualified for small wind energy converters, is explained. Weight and cost of the MODA 10 are considered.

  4. Multiple pulse electron beam converter design for high power radiography

    Science.gov (United States)

    Pincosy, P. A.; Back, N.; Bergstrom, P. M.; Chen, Yu-Jiuan; Poulsen, P.

    2001-06-01

    The typical response of the x-ray converter material to the passage of a high-powered relativistic electron beam is vaporization and rapid dispersal. The effect of this dispersal on subsequent pulses for multi-pulse radiography is the collective effects on the propagation of the electron beam through the expanding plasma and the reduced number of electron to photon interactions. Thus, for the dual-axis radiographic hydrodynamic test facility, the converter material must either be replaced or confined long enough to accommodate the entire pulse train. Typically the 1-mm-thick high Z and full density converter material is chosen to give peak dose and minimum radiographic spot. For repeated pulses we propose a modified converter, constructed of either low density, high Z material in the form of foam or of foils spaced over ten times the axial thickness of the standard 1 mm converter. The converter material is confined within a tube to impede outward motion in radius outside the beam interaction region. We report single-pulse experiments which measure the dose and spot size produced by the modified converter and compare them to similar measurements made by the standard converter. For multiple pulses over a microsecond time scale, we calculate the radial and axial hydrodynamic flow to study the material reflux into the converter volume and the resultant density decrease as the electron beam energy is deposited. Both the electron transport through the expanding low density plasma and beam in the higher density material are modeled. The x-ray source dose and spot size are calculated to evaluate the impact of the changing converter material density distribution on the radiographic spot size and dose. The results indicate that a multiple-pulse converter design for three or four high-power beam pulses is feasible.

  5. Efficient Wide Range Converters (EWiRaC): A new family of high efficient AC-DC Converters

    DEFF Research Database (Denmark)

    Petersen, Lars; Andersen, Michael Andreas E.

    2006-01-01

    suffers a major penalty in efficiency when used at the low end of the voltage range (90VAC) in a universal voltage range application (90-270VAC). This paper addresses this problem by suggesting a new family of converters that effectively reduces the apparent voltage range with a factor of 2 by changing...... the converter topology according to the input voltage. This new converter type has been named: efficient wide range converter (EWiRaC). The performance of the EWiRaC is experimental verified in a universal input range (90-270VAC) application with an output voltage of 185VDC capable of 500W output power. The EWi...

  6. Converting hard copy documents for electronic dissemination

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, F.

    1994-12-31

    Since the advent of computer systems, the goal of a paperless office, and even a paperless society, has been pursued. While the normal paper flow in an organization is far from totally automated, particularly for items requiring signatures or authorizations, electronic information dissemination is becoming an almost simple task. The reasons for providing on-line documents are many and include faster and easier access for everyone, elimination of printing costs, reduction of wasted shelf and desk space, and the security of having a centrally-located, always up-to-date document. New computer software even provides the user with the ability to annotate documents and to have bookmarks so that the old scribbled-in and dog-eared manual can be replaced without loosing this `customizability`. Moreover, new hypermedia capabilities mean that documents can be read in a non-linear fashion and can include color figures and photographs, audio, and even animation sequences, capabilities which exceed those of paper. The proliferation of network-based information servers, coupled with the growth of the Internet, has enticed academic, governmental, and even commercial organizations to provide increasing numbers of documents and data bases in electronic form via the network, not just to internal staff, but to the public as well. Much of this information, which includes everything from mundane company procedures to spiffy marketing brochures, was previously published only in hard copy. Converting existing documents to electronic form and producing only electronic versions of new documents poses some interesting challenges to the maintainer or author.

  7. A New Perspective for Modeling Power Electronics Converters : Complementarity Framework

    NARCIS (Netherlands)

    Vasca, Francesco; Iannelli, Luigi; Camlibel, M. Kanat; Frasca, Roberto

    2009-01-01

    The switching behavior of power converters with "ideal" electronic devices (EDs) makes it difficult to define a switched model that describes the dynamics of the converter in all possible operating conditions, i.e., a "complete" model. Indeed, simplifying assumptions on the sequences of modes are

  8. A nine-level hybrid symmetric cascaded multilevel converter for ...

    Indian Academy of Sciences (India)

    Indrajit Sarkar

    Therefore, due to this limitation of asymmetric or hybrid cascaded converters on input power quality, the use of these converters is popular for electric vehicle applications, and have limited industrial use [20]. Several attempts have been made to increase the number of output voltage levels of symmetric CHB–MLCs as well.

  9. Isolated step-down DC -DC converter for electric vehicles

    Science.gov (United States)

    Kukovinets, O. V.; Sidorov, K. M.; Yutt, V. E.

    2018-02-01

    Modern motor-vehicle industrial sector is moving rapidly now towards the electricity-driving cars production, improving their range and efficiency of components, and in particular the step-down DC/DC converter to supply the onboard circuit 12/24V of electric vehicle from the high-voltage battery. The purpose of this article - to identify the best circuitry topology to design an advanced step-down DC/DC converters with the smallest mass, volume, highest efficiency and power. And this will have a positive effect on driving distance of electric vehicle (EV). On the basis of computational research of existing and implemented circuit topologies of step-down DC/DC converters (serial resonant converter, full bridge with phase-shifting converter, LLC resonant converter) a comprehensive analysis was carried out on the following characteristics: specific volume, specific weight, power, efficiency. The data obtained was the basis for the best technical option - LLC resonant converter. The results can serve as a guide material in the process of components design of the traction equipment for electric vehicles, providing for the best technical solutions in the design and manufacturing of converting equipment, self-contained power supply systems and advanced driver assistance systems.

  10. Design of state observer for modular multilevel converter

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    Modular multilevel converter (MMC) is an attractive choice for transformer-less and filter-less high power conversion system due to its ability to upscale to high voltage levels by the use of semiconductors. The capacitor voltages on each converter cell are important variables to be monitored...

  11. Stabilizing control for power converters connected to transmission lines

    NARCIS (Netherlands)

    Zainea, Marius; Schaft, Arjan van der; Buisson, Jean

    2007-01-01

    This paper proposes a switching control strategy for the set-point stabilization of a power converter connected via a transmission line to a resistive load. The strategy employs a Lyapunov function that is directly based on energy considerations of the power converter, as well as of the transmission

  12. An improved 4-step commutation method application for matrix converter

    DEFF Research Database (Denmark)

    Guo, Yu; Guo, Yougui; Deng, Wenlang

    2014-01-01

    A novel four-step commutation method is proposed for matrix converter cell, 3 phase inputs to 1 phase output in this paper, which is obtained on the analysis of published commutation methods for matrix converter. The first and fourth step can be shorter than the second or third one. The discussed...

  13. Program Converts VAX Floating-Point Data To UNIX

    Science.gov (United States)

    Alves, Marcos; Chapman, Bruce; Chu, Eugene

    1996-01-01

    VAX Floating Point to Host Floating Point Conversion (VAXFC) software converts non-ASCII files to unformatted floating-point representation of UNIX machine. This is done by reading bytes bit by bit, converting them to floating-point numbers, then writing results to another file. Useful when data files created by VAX computer must be used on other machines. Written in C language.

  14. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago

    2012-01-01

    This letter introduces a new series of multilevel (ML) converters based on the ML clamping concept. By applying this technique, a ML clamping unit (MCU) conveys additional levels for synthesizing the output waveforms of a diode-clampedML dc– ac power converter. The basic building block of the ML ...

  15. Multifunctional Converter Drive for Automotive Electric Power Steering Systems

    NARCIS (Netherlands)

    Hackner, T.J.

    2013-01-01

    In this thesis it is shown that in the case of an automotive electric power steering system, critical pulse power loads can be decoupled from the power net with a storage element and a multifunctional converter. A multifunctional converter system is proposed because it uses the motor drive system as

  16. Renovating the excitation circuit of a conventional welding converter

    Indian Academy of Sciences (India)

    current. For this purpose phase control and PWM control techniques were employed. These two solutions were theoretically and practically examined. 2. A general description of the existing direct current arc welding converter. The old existing converter is composed of a direct current generator, a three-phase induction.

  17. Three-channel integrating analog-to-digital converter

    Science.gov (United States)

    Stevens, G. L.

    1978-01-01

    A three-channel integrating analog-to-digital converter was added to the complex mixer system to accept the baseband, complex signals generated by the complex mixers and output binary data to the digital demodulator for further processing and recording. The converter was first used for processing multistation data in radar experiments in the spring of 1977.

  18. Comparative Toxicity of Three Inhibitors of The Converting Enzyme ...

    African Journals Online (AJOL)

    User

    2012-07-12

    Jul 12, 2012 ... Three angiotensin converting enzyme (ACE) inhibitors, enalapril, lisinopril and captopril were tested in vivo by topical ... Key words: Ephestia kuehniella, development, growth, ecdysteroids, angiotensin converting enzyme, captopril, enalapril ... High levels of ACE activity are found in the haemolymph and in ...

  19. 78 FR 40132 - Wave Energy Converter Prize Administration Webinar

    Science.gov (United States)

    2013-07-03

    ... alternative strategies and approaches for the prize administration. A multi stage-gate challenge structure... of Energy Efficiency and Renewable Energy Wave Energy Converter Prize Administration Webinar AGENCY... Energy Converter Prize Administration''. The Office is planning a webinar in advance of any potential FOA...

  20. Platinum recovery from used auto catalytic converters in electrorefining process

    Directory of Open Access Journals (Sweden)

    A. Fornalczyk

    2013-04-01

    Full Text Available This paper presents possibility of removing platinum from the used catalytic converters applying copper as a metal collector in pyrometallurgical methods. The catalytic converter carrier was grinded and melted with copper. During the research obtained Cu-Pt alloy was casted as an anode. Such anode was electrically refined in order to recover platinum. Obtained results were discussed.

  1. Power factor correction (PFC) converters feeding brushless DC ...

    African Journals Online (AJOL)

    This paper presents a comprehensive study of power factor correction (PFC) converters for feeding brushless DC (BLDC) motor drive. This work explores various configurations of PFC converters which are classified into five different categories of non-isolated, bridgeless (BL) non-isolated, isolated, BL-isolated PFC ...

  2. Four-quadrant flyback converter for direct audio power amplification

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a bidirectional, four-quadrant flyback converter for use in direct audio power amplification. When compared to the standard Class-D switching audio power amplifier with a separate power supply, the proposed four-quadrant flyback converter provides simple solution with better...

  3. Pilot tones in WDM networks with wavelength converters

    DEFF Research Database (Denmark)

    Kloch, Allan; Mikkelsen, Benny; Stubkjær, Kristian

    1997-01-01

    Here we investigate the transmission of a pilot tone through an interferometric wavelength converter (IWC) in conjunction with a 2.5 Gbit/s experiment. The pilot tone is added by sinusoidal modulation of the bias current to the signal laser. After the IWC (Michelson interferometer) the converted ...

  4. Impedance Coordinative Control for Cascaded Converter in Bidirectional Application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Deng, Fujin; Chen, Zhe

    2015-01-01

    Two stage cascaded converters are widely used in bidirectional applications, but the negative impedance may cause system instability. Actually the impedance interaction is much different between forward power flow and reversed power flow, which will introduce more uncertainty to the system...... stability. This paper proposes a control method for the constant power controlled converter in cascaded system, and consequently it can change the negative impedance of constant power converter into resistive impedance, which will improve the cascaded system stability, as well as merge the impedance...... difference between forward and reversed power flow. This paper addresses the analysis with the topology of cascaded dual-active-bridge converter (DAB) with inverter, and the proposed control method can also be implemented in unidirectional applications and other general cascaded converter system...

  5. Dividends Sharing Convertible Bonds Pricing and Numerical Evaluation

    Directory of Open Access Journals (Sweden)

    Xu Guo

    2013-01-01

    Full Text Available The convertible bond is becoming one of the most important financial instruments for the company to raise capital fund since it was first issued by American New York Erie Company in 1843. In this paper, it is the first time to study the pricing problem for convertible bond whose underlying stocks pay dividends via the reflected backward stochastic differential equations. Associating the solutions of reflected BSDEs with the obstacle problems for nonlinear parabolic PDEs, we establish the pricing formulas for convertible bonds with continuous and discrete dividends by means of the viscosity solutions for some PDEs. Besides, we also derive the price of convertible bonds with higher borrowing rate which is realistic in the financial market. Then the numerical evaluations are provided by the radial basis functions method. Moreover, we discuss the influence of dividends paying as well as higher borrowing rate on the convertible bond price at last.

  6. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    converter, sinusoidal input current and output voltage can be achieved with minimized rectification switching loss, rendering the indirect matrix converter as a competitive choice for interfacing the utility grid to, e.g., defense facilities that require a different frequency supply. As an improvement......An indirect matrix converter is an alternative "all-semiconductor" energy processor proposed recently for converting an ac source with fixed magnitude and frequency to a variable voltage and frequency supply that can meet the requirements of a particular industry application. In principle......, an indirect matrix converter is constructed by connecting a front-end bidirectional rectification stage to a conventional two-level inversion stage with no bulky capacitive or inductive energy storage connected to their intermediate dc link. Through the proper modulation and compensation of the resulting...

  7. Sheppard-Taylor Isolated High Boost DC-DC Converter

    DEFF Research Database (Denmark)

    Chub, Andrii; Siwakoti, Yam Prasad; Vinnikov, Dmitri

    2017-01-01

    be implemented with fewer passive components. Soft-switching in semiconductors allows achieving high efficiency. In addition, the input side current is continuous. The operating principle and the design guidelines derived for the converter are presented. Theoretical results are supported with experimental......This paper presents a new galvanically isolated step-up dc-dc converter intended for low-power but high step-up applications. The proposed converter is capable of regulating output voltage within a wide range of the input voltage or load variations. In contrast to competitors, the converter can...... results obtained using a 100 W prototype. The converter proposed can be used in photovoltaic module level power electronics applications, where a wide input voltage and load regulation range are highly demanded....

  8. Grid converter for LED based intelligent light sources

    DEFF Research Database (Denmark)

    Török, Lajos

    of the PI controller. All four control loops were implemented in a 16 bitfixed point dsPIC33FJ32GS406 microcontroller driving at the same time 8 PWM channels. Finally a brief analysis was done on the eect of the grid disturbances, especially voltage sags on the digital controller. Dierent grid codes...... and voltage control this topology can be modeled as a interleaved synchronous buck converter. As it can be seen interleaving technique is also present in this topology. For this topology a fuzzy logic voltage controller is proposed and compared to the traditional PI controller. After modeling the converters...... prototype was a 70 W two-stage PFC and DC-DC converter with boost and forward converters. Average current mode control was selected, designed, simulated an implemented for the boost PFC converter. The two-loop control structure (fast internal current loop and lower bandwidth external voltage loop...

  9. Estimation of reliability of a interleaving PFC boost converter

    Directory of Open Access Journals (Sweden)

    Gulam Amer Sandepudi

    2010-01-01

    Full Text Available Reliability plays an important role in power supplies. For other electronic equipment, a certain failure mode, at least for a part of the total system, can often be employed without serious (critical effects. However, for power supply no such condition can be accepted, since very high demands on its reliability must be achieved. At higher power levels, the continuous conduction mode (CCM boost converter is preferred topology for implementation a front end with PFC. As a result, significant efforts have been made to improve the performance of high boost converter. This paper is one of the efforts for improving the performance of the converter from the reliability point of view. In this paper, interleaving boost power factor correction converter is simulated with single switch in continuous conduction mode (CCM, discontinuous conduction mode (DCM and critical conduction mode (CRM under different output power ratings. Results of the converter are explored from reliability point of view.

  10. The New Modular Control System for Power Converters at CERN

    CERN Document Server

    Di Cosmo, Matteo

    2015-01-01

    The CERN accelerator complex consists of several generations of particle accelerators, with around 5000 power converters supplying regulated current and voltage to normal and superconducting magnet circuits. Today around 12 generations of converter control platforms can be found in the accelerator complex, ranging in age and technology. The diversity of these platforms has a significant impact on operability, maintenance and support of power converters. Over the past few years a new generation of modular controls called RegFGC3 has been developed by CERN’s power conversion group, with a goal to provide a standardised control platform, supporting a wide variety of converter topologies. The aim of this project is to reduce maintenance costs by decreasing the variety and diversity of control systems whilst simultaneously improving the operability and reliability of power converters and their controls. This paper describes the state of the on-going design and realization of the RegFGC3 platform, focusing on fun...

  11. Particle-In-Cell Simulations of a Thermionic Converter

    Science.gov (United States)

    Clark, Stephen

    2017-10-01

    Simulations of thermionic converters are presented where cesium is used as a work function reducing agent in a nano-fabricated triode configuration. The cathode and anode are spaced on the order of 100 μm, and the grid structure has features on the micron scale near the anode. The hot side is operated near 1600 K, the cold side near 600 K, and the converter has the potential to convert heat to DC electrical current upwards of 20% efficiency. Affordable and robust thermionic converters have the potential to displace century old mechanical engines and turbines as a primary means of electrical power generation in the near future. High efficiency converters that operate at a small scale could be used to generate power locally and alleviate the need for large scale power transmission systems. Electron and negative cesium ion back emission from the anode are considered, as well as device longevity and fabrication feasibility.

  12. An Innovative Reconfigurable Integrated Converter Topology Suitable for Distributed Generation

    Directory of Open Access Journals (Sweden)

    Renato Rizzo

    2012-09-01

    Full Text Available The electricity market and environmental concerns, with wide utilization of renewable sources, have improved the diffusion of distributed generation units changing the operations of distribution grids from passive networks to microgrids. A microgrid includes a cluster of electrical loads, energy storage devices and microsources, which provide both power and heat to their local area. A microgrid has usually one connection point to the utility grid through power electronic converters placed at customers’ sites. This paper analyses a Reconfigurable Integrated Converter (RIC used for a domestic microgrid with inputs from the AC mains and photovoltaic arrays, and two DC outputs at different voltage levels. A RIC as a dual-boost DC-DC converter is proposed, modelled and analysed in the paper. The advantages of such a topology in comparison with traditional boost converters are outlined. Reported simulations results give evidence on the controllability of this converter and the capability of achieving the desired voltage outputs with reduced ripple.

  13. Optimisation Of a Magnetostrictive Wave Energy Converter

    Science.gov (United States)

    Mundon, T. R.; Nair, B.

    2014-12-01

    Oscilla Power, Inc. (OPI) is developing a patented magnetostrictive wave energy converter aimed at reducing the cost of grid-scale electricity from ocean waves. Designed to operate cost-effectively across a wide range of wave conditions, this will be the first use of reverse magnetostriction for large-scale energy production. The device architecture is a straightforward two-body, point absorbing system that has been studied at length by various researchers. A large surface float is anchored to a submerged heave (reaction) plate by multiple taut tethers that are largely made up of discrete, robust power takeoff modules that house the magnetostrictive generators. The unique generators developed by OPI utilize the phenomenon of reverse magnetostriction, which through the application of load to a specific low cost alloy, can generate significant magnetic flux changes, and thus create power through electromagnetic induction. Unlike traditional generators, the mode of operation is low-displacement, high-force, high damping which in combination with the specific multi-tether configuration creates some unique effects and interesting optimization challenges. Using an empirical approach with a combination of numerical tools, such as ORCAFLEX, and physical models, we investigated the properties and sensitivities of this system arrangement, including various heave plate geometries, with the overall goal of identifying the mass and hydrodynamic parameters required for optimum performance. Furthermore, through a detailed physical model test program at the University of New Hampshire, we were able to study in more detail how the heave plate geometry affects the drag and added mass coefficients. In presenting this work we will discuss how alternate geometries could be used to optimize the hydrodynamic parameters of the heave plate, allowing maximum inertial forces in operational conditions, while simultaneously minimizing the forces generated in extreme waves. This presentation

  14. A Model Predictive Control-Based Power Converter System for Oscillating Water Column Wave Energy Converters

    Directory of Open Access Journals (Sweden)

    Gimara Rajapakse

    2017-10-01

    Full Text Available Despite the predictability and availability at large scale, wave energy conversion (WEC has still not become a mainstream renewable energy technology. One of the main reasons is the large variations in the extracted power which could lead to instabilities in the power grid. In addition, maintaining the speed of the turbine within optimal range under changing wave conditions is another control challenge, especially in oscillating water column (OWC type WEC systems. As a solution to the first issue, this paper proposes the direct connection of a battery bank into the dc-link of the back-to-back power converter system, thereby smoothening the power delivered to the grid. For the second issue, model predictive controllers (MPCs are developed for the rectifier and the inverter of the back-to-back converter system aiming to maintain the turbine speed within its optimum range. In addition, MPC controllers are designed to control the battery current as well, in both charging and discharging conditions. Operations of the proposed battery direct integration scheme and control solutions are verified through computer simulations. Simulation results show that the proposed integrated energy storage and control solutions are capable of delivering smooth power to the grid while maintaining the turbine speed within its optimum range under varying wave conditions.

  15. A new method of converter transformer protection without commutation failure

    Science.gov (United States)

    Zhang, Jiayu; Kong, Bo; Liu, Mingchang; Zhang, Jun; Guo, Jianhong; Jing, Xu

    2018-01-01

    With the development of AC / DC hybrid transmission technology, converter transformer as nodes of AC and DC conversion of HVDC transmission technology, its reliable safe and stable operation plays an important role in the DC transmission. As a common problem of DC transmission, commutation failure poses a serious threat to the safe and stable operation of power grid. According to the commutation relation between the AC bus voltage of converter station and the output DC voltage of converter, the generalized transformation ratio is defined, and a new method of converter transformer protection based on generalized transformation ratio is put forward. The method uses generalized ratio to realize the on-line monitoring of the fault or abnormal commutation components, and the use of valve side of converter transformer bushing CT current characteristics of converter transformer fault accurately, and is not influenced by the presence of commutation failure. Through the fault analysis and EMTDC/PSCAD simulation, the protection can be operated correctly under the condition of various faults of the converter.

  16. Dynamic Evolution Control for Fuel Cell DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Ahmad Saudi Samosir

    2011-04-01

    Full Text Available Fuel cells are new alternative energy resource that has a great promise for distributed generation and electric vehicle application. However, fuel cells have a slow response due to their slow internal electromechanical and thermodynamic response. To optimize the fuel cell system performance, a fuel cell DC-DC converter with an appropriate controller which can regulate the power flow and automatically adjust the converter output voltage is needed. This paper proposes a new control technique for fuel cell DC-DC power converter. Design of the proposed control method for fuel cell DC-DC power converter is provided. A new approach for converter controllers synthesis based on dynamic evolution control theory is presented. In this paper, synthesis example of boost DC-DC converter is discussed. Performance of the proposed dynamic evolution control under step load variation condition is simulated under Matlab-Simulink environment. Simulation results show that the proposed techniques are capable for controlling fuel cell DC-DC converter.

  17. A Signal-Interleaving Complex Bandpass Sigma-Delta Converter

    DEFF Research Database (Denmark)

    Wad, Paul Emmanuel

    1997-01-01

    Complex or quadrature Sigma-Delta converters operate on complex signals, i.e. signals consisting of a real and an imaginary component, whereas conventional converters operate only on real signals. The advantage of complex signal processing in the discrete-time domain is that the entire sampling f...... than conventional converters, and a new signal-interleaving switched-capacitor architecture is derived for these complex converters.......Complex or quadrature Sigma-Delta converters operate on complex signals, i.e. signals consisting of a real and an imaginary component, whereas conventional converters operate only on real signals. The advantage of complex signal processing in the discrete-time domain is that the entire sampling...... frequency bandwidth - not just half of it - is available, and that network zeros and poles can be placed anywhere without having to appear in complex conjugate pairs. This paper demonstrates how these properties can be used to design complex bandpass Sigma-Delta converters with a better noise performance...

  18. Study of switching transients in high frequency converters

    Science.gov (United States)

    Zinger, Donald S.; Elbuluk, Malik E.; Lee, Tony

    1993-01-01

    As the semiconductor technologies progress rapidly, the power densities and switching frequencies of many power devices are improved. With the existing technology, high frequency power systems become possible. Use of such a system is advantageous in many aspects. A high frequency ac source is used as the direct input to an ac/ac pulse-density-modulation (PDM) converter. This converter is a new concept which employs zero voltage switching techniques. However, the development of this converter is still in its infancy stage. There are problems associated with this converter such as a high on-voltage drop, switching transients, and zero-crossing detecting. Considering these problems, the switching speed and power handling capabilities of the MOS-Controlled Thyristor (MCT) makes the device the most promising candidate for this application. A complete insight of component considerations for building an ac/ac PDM converter for a high frequency power system is addressed. A power device review is first presented. The ac/ac PDM converter requires switches that can conduct bi-directional current and block bi-directional voltage. These bi-directional switches can be constructed using existing power devices. Different bi-directional switches for the converter are investigated. Detailed experimental studies of the characteristics of the MCT under hard switching and zero-voltage switching are also presented. One disadvantage of an ac/ac converter is that turn-on and turn-off of the switches has to be completed instantaneously when the ac source is at zero voltage. Otherwise shoot-through current or voltage spikes can occur which can be hazardous to the devices. In order for the devices to switch softly in the safe operating area even under non-ideal cases, a unique snubber circuit is used in each bi-directional switch. Detailed theory and experimental results for circuits using these snubbers are presented. A current regulated ac/ac PDM converter built using MCT's and IGBT's is

  19. Architecture for a High-to-Medium-Voltage Power Converter

    Science.gov (United States)

    Vorpenian, Vatche

    2008-01-01

    A power converter now undergoing development is required to operate at a DC input potential ranging between 5.5 and 10 kV and a DC output potential of 400 V at a current up to 25 A. This power converter is also required to be sufficiently compact and reliable to fit and operate within the confines of a high-pressure case to be lowered to several miles (approx.5 km) below the surface of the ocean. The architecture chosen to satisfy these requirements calls for a series/ parallel arrangement of 48 high-frequency, pulse-width-modulation (PWM), transformer-isolation DC-to-DC power converter blocks. The input sides of the converter blocks would be connected in series so that the input potential would be divided among them, each of them being exposed to an input potential of no more than 10 kV/48 . 210 V. The series connection of inputs would also enforce a requirement that all the converter blocks operate at the same input current. The outputs of the converter blocks would be connected in a matrix comprising 6 parallel legs, each leg being a cascade of eight outputs wired in series (see figure). All the converter blocks would be identical within the tolerances of the values of their components. A single voltage feedback loop would regulate the output potential. All the converter blocks would be driven by the same PWM waveform generated by this feedback loop. The power transformer of each converter block would have a unity turns ratio and would be capable of withstanding as much as 10 kVDC between its primary and secondary windings. (Although, in general, the turns ratio could be different from unity, the simplest construction for minimizing leakage and maximizing breakdown voltage is attained at a turns ratio of unity.)

  20. New active load voltage clamp for HF-link converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, M.A.E.

    2005-07-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core. (au)

  1. Conducted EMI Evaluation and Reduction in a Forward Switching Converter

    Directory of Open Access Journals (Sweden)

    Mohammad Rouhollah Yazdani

    2012-04-01

    Full Text Available In switching power converters, electromagnetic interference (EMI is produced due to the fast changes of the voltage and current. Among switching topologies used in low and medium powers, forward converter is vastly employed which needs resetting transformer core. In this paper, a forward converter with reset winding is modeled to predict conducted EMI. To evaluate the EMI model, EMI measurement results are presented. To select an optimum reset scheme from EMI viewpoint, three reset techniques are compared using experimental results. After selecting the proper reset scheme, two EMI mitigation methods are proposed and the practical EMI reduction is presented.

  2. Digital to Analog Converter Dac 0800 with Pc-based

    OpenAIRE

    Dedy Erwan Kustianto; Ir. Irawan Nimara, MM

    2000-01-01

    Computer produces a digital signal output of logic "0" and "1". While electronicdevices typically use an analog signal as a voltage source that a certain amount.Electronic devices that require analog signals can be connected to a computer using adigital to analog converter circuit. Digital to analog converter is used to change thedigital signal into analogue signal.To be able to relate to the computer to analog converter circuit, an interface is needed.The interface is often used in design is...

  3. A DSP controlled one-to-three phase matrix converter

    Energy Technology Data Exchange (ETDEWEB)

    Dubovsky, J.; Dobrucly, B; Tabacek, R.; Havrila, R. [Department of Electric Traction and Energetics Faculty of Electrical Engineering, University of Zilina (Slovakia)

    1997-12-31

    This paper deals with the theoretical analysis computer simulation and experimental results of IM fed by a one-to-three phase matrix converter which offers a unique solution for single phase electric traction applications. The proposed drive in comparison with currently used conventional drives reduces the number of power switching elements of the converter, which increases drives dependability and brings lower investment in power electronics used in drive. Further advantage is that the converter is controlled with nearly unity power factor which cuts down the operational expenses and offers higher overall performance of the drive. (orig.) 6 refs.

  4. Thyristor voltage converter in induction electric drives with microprocessor control

    Energy Technology Data Exchange (ETDEWEB)

    Braslavsky, I.; Zuzev, A.; Shilin, S. [Electric Drive Department, Urals State Technical University, Ekaterinburg (Russian Federation)

    1997-12-31

    The paper consists of some results on developed pulse model of thyristor voltage converter which is one of the most mathematically complicated unit of electric drive. The model structure and model parameter calculating method are represented. The application of the model allows to analyse stability in `locally` by the linear pulse system theory methods with talking into consideration quantise processes within the converter. Such application provides the obtaining higher accurate results comparing with the non-linear system theory approximate methods. Logarithmic frequency characteristics are used to analyse converter dynamic features and they are represented too. (orig.) 4 refs.

  5. Pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2008-01-01

    This book studies switch-mode power supplies (SMPS) in great detail. This type of converter changes an unregulated DC voltage into a high-frequency pulse-width modulated (PWM) voltage controlled by varying the duty cycle, then changes the PWM AC voltage to a regulated DC voltage at a high efficiency by rectification and filtering. Used to supply electronic circuits, this converter saves energy and space in the overall system. With concept-orientated explanations, this book offers state-of-the-art SMPS technology and promotes an understanding of the principle operations of PWM converters,

  6. Converting an NFA to a DFA with programming C++

    OpenAIRE

    M. Davoudi-Monfared; R. shafiezadehgarousi; E. S. Haghi; Zeinali, S; S.Mohebali

    2015-01-01

    In Automata Theory, if a language is recognized bay a Non-deterministic finite automaton (NFA), then we must show the existence of deterministic finite automaton (DFA) that also recognizes it. There are many idea and algorithms to convert an NFA in to an equivalent DFA that simulates the NFA. In this paper, we present an algorithm to convert an NFA to a DFA with programming by C++. This approach contains several classes and is so universal that cover converting from NFA to DFA completely.

  7. Primary Parallel Isolated Boost Converter with Bidirectional Operation

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gökhan

    2012-01-01

    This paper presents a bidirectional dc/dc converter operated with batteries both in the input and output. Primary parallel isolated boost converter (PPIBC) with transformer series connection on the high voltage side is preferred due to its ability to handle high currents in the low voltage side....... The converter has been modeled using non-ideal components and operated without any additional circuitry for startup using a digital soft-start procedure. Simulated and measured loop gains have been compared for the validity of the model. On-the-fly current direction change has been achieved between input...

  8. High Efficiency Boost Converter with Three State Switching Cell

    DEFF Research Database (Denmark)

    Klimczak, Pawel; Munk-Nielsen, Stig

    2009-01-01

    The boost converter with the three-state switching cell seems to be a good candidate for a dc-dc stage for non-isolated generators based on alternative energy sources. It provides a high voltage gain, a reduced voltage stress on transistors and limited input current ripples. In this paper the focus...... is on performance improvement of this type of the converter. Use of foil windings helps to reduce conduction losses in magnetic components and to reduce size of these components. Also it has been demonstrated that the regulation range of this type of converter can be increased by operation with duty cycle lower...

  9. Soft switching buck-boost converter for photovoltaic power generation; Taiyoko hatsuden no tame no soft switching shokoatsu converter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H. [Kyungnam University (Korea, Republic of)

    1996-10-27

    A soft switching method with small switching loss was proposed for the purpose of increasing the efficiency of a DC-DC boost converter which converted a DC current generated by solar cells to a variable DC current. Existing current converters are supplemented by using a snubber circuit around the switch so as to protect the switch by a hard switching action. However, with an increase of the output current, snubber loss is increased, reducing the efficiency. In order to solve this problem, the partial resonant switch method was applied to the converter; with this method of partially forming a resonant circuit only at the time of turning on/off of the switch, the switching loss was reduced through the soft switching, thereby making the proposed converter operate with high efficiency. Moreover, the resonant element of the partial resonant circuit using a snubber condenser, the energy accumulated in the condenser was regenerated on the power supply side without loss of snubber. With the regenerated energy, the proposed converter was provided with a smaller ratio of switching to use than the conventional converter. 4 refs., 7 figs., 1 tab.

  10. Características morfológicas de gramas em resposta à aplicação de trinexapac-ethyl Morphological characteristics of turf grasses in response to trinexapac-ethyl application

    Directory of Open Access Journals (Sweden)

    N.V. Costa

    2009-03-01

    Full Text Available O presente trabalho teve como objetivo avaliar os efeitos da aplicação de duas doses de trinexapac-ethyl sobre a morfologia das espécies de gramas São Carlos (Axonopus compressus, Batatais (Paspalum notatum, Santo Agostinho (Stenotaphrum secundatum e Esmeralda (Zoysia japonica. Os gramados foram cortados à altura de 3 cm no início do experimento e 20 dias depois. Após cada corte, foram realizadas duas aplicações sequenciais de trinexapac-ethyl nas doses de 56,5 + 56,5 e 113,0 + 113,0 g ha-1 , além de uma testemunha sem aplicação, para cada espécie avaliada. O delineamento experimental utilizado foi o de blocos ao acaso com quatro repetições. A redução do crescimento foi avaliada por meio da altura das plantas. Semanalmente, o número e altura de inflorescências foram avaliados por amostragem, realizada em 0,25 m² no centro das parcelas; no final do experimento, avaliou-se a massa seca total. A aplicação do trinexapac-ethyl retardou o crescimento vegetativo e a emissão das inflorescências, assim como não provocou danos aparentes nos gramados. O uso do trinexapac-ethyl nos gramados avaliados pode reduzir a necessidade de cortes em até 55 dias após a segunda aplicação.The aim of this research was to evaluate the effects of the sequential application of two rates of trinexapac-ethyl on the morphology of the following turf grass species: Broadleaf Carpetgrass (Axonopus compressus, Bahiagrass (Paspalum notatum, St. Augustinegrass (Stenotaphrum secundatum and Korean Lawngrass (Zoysia japonica. The treatments used were trinexapac-ethyl with two sprays applied at 20 day interval at two different rates (56.5 + 56.5 and 113.0 + 113.0 g ha-1 and a control without spraying, for each species. The turf grasses were cut at the height of 3 cm, and sprayed after the treatments. Twenty days after the first treatment application, the plots were cut again and the second treatment application was carried out. The experiment was arranged in

  11. Intercooled Turbo-Brayton Power Converter for Spaceflight Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Future NASA space missions require advanced systems to convert thermal energy into electric power. These systems must be reliable, efficient, and lightweight. In...

  12. Ultrasonic series resonant converter with integrated L-C-T

    CSIR Research Space (South Africa)

    Smit, MC

    1995-01-01

    Full Text Available The concept of an integrated structure for the capacitor, inductor and transformer of the series resonant converters presented. It is shown that the necessary capacitance can be achieved by using a bifilar primary and the leakage inductance...

  13. High Input Voltage Hall Thruster Discharge Converter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall scope of this Phase I/II effort is the development of a high efficiency 15kW (nominal) Hall thruster discharge converter. In Phase I, Busek Co. Inc. will...

  14. Device Loading of Modular Multilevel Converter in Wind Power

    DEFF Research Database (Denmark)

    Popova, L.; Ma, Ke; Blaabjerg, Frede

    2015-01-01

    Modular multilevel converter (MMC) is a recently emerged multilevel topology for high-voltage high-power applications. However, in wind power applications, to the best of the authors knowledge, the performance of the MMC has not been extensively investigated. In this paper, the application...... of the MMC to wind energy systems is studied. The converters used to connect the wind turbine to the grid, which have rated active powers of 2MW and 10MW, are proposed and investigated. The electrical losses and thermal loading of the power devices in the proposed converter solutions are analyzed based...... on the gird conditions/requirements for wind power. The efficiency of the MMC under different P/Q boundaries defined by grid codes is investigated and compared with two-level (2L) and three-level (3L) neutral point clamped converters. It is concluded that it is possible to use the MMC in wind power...

  15. Step-Up DC-DC Power Converter

    DEFF Research Database (Denmark)

    2015-01-01

    capacitor coupled between the positive and negative input terminals and the secondary side circuit comprises an output capacitor chargeable to a converter output voltage between a first positive electrode and a second negative electrode. A switched energy storage network is configured for alternatingly...... being charged from the input voltage and discharged to the output capacitor through the galvanic isolation barrier in accordance with a switch control signal to produce the converter output voltage. The step-up DC-DC power converter comprises an electrical short-circuit connection across the galvanic......The present invention relates to a step-up DC-DC power converter which comprises a primary side circuit and a secondary side circuit coupled through a galvanic isolation barrier. The primary side circuit comprises a positive and a negative input terminal for receipt of an input voltage and an input...

  16. A New Asymmetrical Current-fed Converter with Voltage Lifting

    Directory of Open Access Journals (Sweden)

    DELSHAD, M.

    2011-05-01

    Full Text Available This paper presents a new zero voltage switching current-fed DC-DC converter with high voltage gain. In this converter all switches (main and auxiliary turn on under zero voltage switching and turn off under almost zero voltage switching due to snubber capacitor. Furthermore, the voltage spike across the main switch due to leakage inductance of forward transformer is absorbed. The flyback transformer which is connected to the output in series causes to high voltage gain and less voltage stress on the power devices. Considering high efficiency and voltage gain of this converter, it is suitable for green generated systems such as fuel cells or photovoltaic systems. The presented experimental results verify the integrity of the proposed converter.

  17. Liquid Nitrogen Temperature Operation of a Switching Power Converter

    Science.gov (United States)

    Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.

    1995-01-01

    The performance of a 42/28 V, 175 W, 50 kHz pulse-width modulated buck dc/dc switching power converter at liquid nitrogen temperature (LNT) is compared with room temperature operation. The power circuit as well as the control circuit of the converter, designed with commercially available components, were operated at LNT and resulted in a slight improvement in converter efficiency. The improvement in power MOSFET operation was offset by deteriorating performance of the output diode rectifier at LNT. Performance of the converter could be further improved at low temperatures by using only power MOSFET's as switches. The use of a resonant topology will further improve the circuit performance by reducing the switching noise and loss.

  18. A Single Switch Dual Output Non-Isolated Boost Converter

    DEFF Research Database (Denmark)

    Klimczak, Pawel; Munk-Nielsen, Stig

    2008-01-01

    very simple dual output non-isolated boost converter is presented. Single active switch is used to control both, positive and negative output voltages. The converter is desired to boost unregulated low input voltage 25-50 Vdc to regulated high voltage ±400 Vdc in dual dc-link. In this paper proposed......There are many applications for high gain dc-dc converters. In several of these applications galvanic isolation is not required, but there are some safety issues regarding missing isolation and leakage current. Usage of a half-bridge inverter and a dual dc-link may solve this issues. In this paper...... topology is analyzed and explained. Obtained experimental results prove good performance of the converter over wide range of input voltage and output power....

  19. A Current-Fed Isolated Bidirectional DC-DC Converter

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Wu, Xiaoying; Shen, Yanfeng

    2017-01-01

    This paper proposes a current-fed isolated bidirectional DC-DC converter (CF-IBDC) which has the advantages of wide input voltage range, low input current ripple, low conduction losses, and soft switching over the full operating range. Compared with conventional CF-IBDCs, the voltage spikes...... of the low-voltage (LV) side switches in the proposed converter can be eliminated without additional clamp circuits. The converter adopts the pulse width modulation (PWM) plus hybrid phase-shift control scheme such that the bus voltage can match the output voltage by means of the transformer. Thus......, the current stresses and conduction losses of the converter become lower. In addition, the practical ZVS of the secondary-side switches can be realized by adjusting the phase-shift angle within the secondary side when in light load or no load condition. The operating principles and characteristics including...

  20. Systematic risk variations (beta convertible debenture brazilian companies

    Directory of Open Access Journals (Sweden)

    Renata Drumond Pinto Coelho Antonino

    2010-01-01

    Full Text Available purpose of this article is to analyze the impact of issuing convertible debentures on the systematic risk of Brazilian companies. Some applied researches in the U.S. capital market (STEIN, 1992; LEWIS et al, 2002; RAI, 2005 indicate that convertible debentures may be used as an alternative financing source when adverse selection problem makes stock issuing unattractive financing source. The analysis of Brazilian companies that issued convertible debentures recorded in the period from 1998 to 2006 and that presented liquidity on the market indicated that variation in beta, on average, is positive. These results are coherent with the signaling hypothesis and with the absence of convertible debenture issuing in 2005 and 2006 on the Brazilian market. They also may be related to the precarious financial situation of issuing companies, observed by the analysis of some financial indicators in year of issue and in two pre- e post-issuing years.

  1. A nonlinearity compensation method for a matrix converter drive

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Blaabjerg, Frede

    2005-01-01

    This paper presents a new method to compensate the nonlinearities for matrix converter drives. The nonlinearities of matrix converter drives such as commutation delay, turn-on and turn-off time of the switching devices, and on-state switching device voltage drop is corrected by a new matrix...... using a 3-kW matrix converter system without a speed sensor. Experimental results show the proposed method provides good compensating characteristics....... converter model using the direction of current. The proposed method does not need any additional hardware or complicated software and it is easy to realize by applying the algorithm to the conventional vector control. The proposed compensation method is applied for high-performance induction motor drives...

  2. Application of the matrix converter to power flow control

    Directory of Open Access Journals (Sweden)

    Szcześniak P.

    2014-09-01

    Full Text Available Advanced power electronic converters can provide the means to control power flow and ensure proper and secure operation of the future power grid. The small electrical energy sources dispersed in electrical power systems referred to as distributed generation are one of the most significant parts of future grids - Smart Grids. The threephase, direct matrix converter is an alternative solution to the conventional AC-DC-AC converter for interfacing two AC systems in distributed power generation with different voltage and/or frequency parameters. This paper presents a control analysis of a threephase matrix converter employed as a power interface of future electrical grids. The proposed system has been successfully tested for bidirectional power flow operation with different grid operating conditions, such as, frequency and voltage variation

  3. A Robust Method to Improve Stability in Matrix Converters

    DEFF Research Database (Denmark)

    Liu, F.; Klumpner, Christian; Blaabjerg, Frede

    2004-01-01

    The last few years witness a high interest in the use of matrix converter technology in AC/AC power conversion. This paper is focusing on its stability issues. It analyzes the instability reason and reveals that the harmonics interaction of its input current and input voltage is the main cause...... of instability. The matrix converter stability can be improved by decoupling its input current with the input voltage. A modulation strategy is presented that satisfies the idea. The difference of the strategy compared with the traditional one only concerns on the definition of the reference angle for the input...... current vector. A matrix converter model that takes the switching behavior and effects related with the digital implementations into consideration is developed for evaluation of the strategy. The simulation results show that the proposed strategy can highly improve the matrix converter stability...

  4. Unregulated Series Resonant Converter for Interlinking DC Nanogrids

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Zhang, Zhe; Ouyang, Ziwei

    2017-01-01

    DC nanogrids have become a subject of interest inrecent years due to the increase of renewable energy sources with energy storage systems. Hybrid AC/DC systems with different DCbuses are an interesting solution to efficiently supply different AC and DC loads. In this paper, a high efficiency bidi...... operation and optimal self-load regulation is presented. To verify the converter operation, a 1kW prototype has been implemented, featuring on maximum efficiency of 96:7% and a self-regulated output voltage with 3% of maximum offset from the nominal voltage....... bidirectional converter to interlink a 400V DC bus with a 48V DC bus ispresented. The proposed converter is based on a LLC resonant converter operating as a DC transformer at a fixed frequency and duty cycle without any complex control strategy. A clearand simplified design procedure for high efficiency...

  5. Parametric algorithms for frequency estimation in PWM converter systems

    Energy Technology Data Exchange (ETDEWEB)

    Lobos, T.; Hejke, I.; Rezmer, J.; Sikorski, T.; Kostyla, P. [Dept. of Electrical Engineering, Wroclaw University of Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw (Poland)

    2009-11-15

    Proper estimation of voltage parameters has a significant meaning for power converters control systems. One of the measured parameter, directly associated with control process, is frequency of the basic voltage component at the converter output. Unfortunately, power converters generate a wide spectrum of harmonics as well as interharmonics, that makes difficulties in estimation this frequency. Measurement carried out in industrial applications exhibits complex nature of investigated signals often corrupted by resonances or overvoltages phenomena. It entails searching a new digital algorithms for frequency measurement. This work presents algorithm using modification of high-resolution Prony method connected with digital filtering. The investigations was based on simulations and real measured signals recorded in two different commercial PWM converters. Obtained results indicate accuracy of the method as well as its fast response. (author)

  6. MULTILEVEL CONVERTERS FOR MICROWELDING BASED ON M-ARY SYSTEM

    Directory of Open Access Journals (Sweden)

    Zhuikov V.

    2012-12-01

    Full Text Available Multilevel converter constructing and functioning principles are given. Two different approaches to increase efficiency are described. Both decisions are compared with typical applications, so advantages and drawbacks are specified.

  7. Three Phase Resonant DC Power Converter for Ion Thrusters Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Our phase 1 study has revealed many significant benefits of a new class of DC-to-DC power converters with performance that cannot be matched by current flight power...

  8. Turbo-Brayton Power Converter for Spaceflight Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Future NASA space missions require advanced systems to convert thermal energy into electric power. These systems must be reliable, efficient, and lightweight. In...

  9. A Comparisson of Synchronous And Nonsynchronous Boost Converter

    Science.gov (United States)

    Isnaeni Romadhon, Mohamad; Andromeda, Trias; Facta, Mochammad; Warsito, Agung

    2017-04-01

    Modern electronic systems require resources with high efficiency. The efficiency of direct current to dicrect current converters as a power source can be increased by replacing a diode with MOSFET. The use of MOSFET is expected to reduce power loss as the internal resistance of MOSFET is lower than a diode. To implement the propossed idea, a boost type direct current chopper and TL494 as PWM generator circuit were applied in this work. MOSFET is used in synchronization mode to replace diode at conventional topology of chopper. The proposed circuit and conventional topology were made and their performance were observed. The efficiency of both circuit were compared and analyzed. The result of the experiments showed that the efficiency of converter within MOSFET at synchronization mode is proportional with the increment of duty cycle, while at conventional topology the efficiency remain stable at any duty cycle. Synchronous boost converter is more efficient than nonsynchronous boost converter at duty cycle over than 40%.

  10. Converting Sunlight to Mechanical Energy: A Polymer Example of Entropy.

    Science.gov (United States)

    Mathias, Lon J.

    1987-01-01

    This experiment/demonstration provides elementary through high school science students with hands-on experience with polymer entropy. Construction of a simple machine for converting light into mechanical energy is described. (RH)

  11. Nonlinear feedback reduces analog-to-digital converter error

    Science.gov (United States)

    Munoz, R. M.

    1965-01-01

    Nonlinear analog-to-digital converter measures the analog input level and continuously adjusts the digital readout scale sensitivity to effectively increase the accuracy. It is able to acquire more accurate low-level data.

  12. LLCL-Filtered Grid Converter with Improved Stability and Robustness

    DEFF Research Database (Denmark)

    Min, Huang; Wang, Xiongfei; Loh, Poh Chiang

    2016-01-01

    LLCL-filter has been proven to introduce more filtering at the converter switching frequency, while using smaller passive components. However, like other higher order filters, it introduces resonance to the grid when used with a grid converter. Its stability and robustness are also affected by grid...... method even with no damping added to the grid converter. The method has been applied to the development of an LLCL-filter for testing in the laboratory with a 5-kW, 400-V, and 50-Hz grid converter. The method can also be applied to the lower order LCL-filter with only a slight modification needed....... impedance variations, making its design more challenging. To address these concerns, a new parameter design method for LLCL-filter has been formulated in the paper, which when enforced, guarantees robust and stable grid current control regardless of how the grid conditions change. It is thus an enhanced...

  13. Power electronic converters and systems frontiers and applications

    CERN Document Server

    Trzynadlowski, Andrzej M

    2016-01-01

    Power electronics is a branch of electrical engineering dealing with conversion and control of electric power using semiconductor power switches. This book provides an overview of modern power electronic converters and systems, and their applications.

  14. Assembly processor program converts symbolic programming language to machine language

    Science.gov (United States)

    Pelto, E. V.

    1967-01-01

    Assembly processor program converts symbolic programming language to machine language. This program translates symbolic codes into computer understandable instructions, assigns locations in storage for successive instructions, and computer locations from symbolic addresses.

  15. Coping with Harmonics in Smart Grid: variable speed driveswith Back-to-Back Voltage Source Converter versus the matrix converter

    OpenAIRE

    Ali, Imran

    2013-01-01

    In this master thesis it has been investigated to utilize the matrix as a shunt active power filter and an adjustable speed drive and then compare the matrix converter with the Back-to-Back voltage source converter in terms of active filtering capability and reactive power compensation.In first steps to utilize the matrix converter as a motor drive and a shunt active power filter the control systems for the Permanent magnet synchronous machine, shunt active power filter and 3-phase LC-filter ...

  16. The APA Style Converter: a Web-based interface for converting articles to APA style for publication.

    Science.gov (United States)

    Li, Ping; Cunningham, Krystal

    2005-05-01

    The APA Style Converter is a Web-based tool with which authors may prepare their articles in APA style according to the APA Publication Manual (5th ed.). The Converter provides a user-friendly interface that allows authors to copy and paste text and upload figures through the Web, and it automatically converts all texts, references, and figures to a structured article in APA style. The output is saved in PDF or RTF format, ready for either electronic submission or hardcopy printing.

  17. Energy Capture Optimization for an Adaptive Wave Energy Converter

    OpenAIRE

    Barradas Berglind, Jose de Jesus; Meijer, Harmen; van Rooij, Marijn; Clemente Pinol, Silvia; Galvan Garcia, Bruno; Prins, Wouter; Vakis, Antonis I.; Jayawardhana, Bayu

    2016-01-01

    Wave energy has great potential as a renewable energy source, and can therefore contribute significantly to the proportion of renewable energy in the global energy mix. This is especially important since energy mixes with high renewable penetration have become a worldwide priority. One solution to facilitate such goals is to harvest the latent untapped energy of the ocean waves and convert it into electrical energy. A device performing such a task is known as a wave energy converter (WEC). In...

  18. Direct energy converter controllers for switched reluctance motor operation

    OpenAIRE

    Goodman, Andrew Simon

    2007-01-01

    There is increasing demand for simple motor drives offering high reliability and fault tolerance in applications such as the aerospace actuator industry, with the development of `more electric aircraft'. This thesis presents a motor drive employing a switched reluctance motor, the novel single sided matrix converter, and a novel double band hysteresis based control scheme for control of the converter, implemented using a field programmable gate array (FPGA). The single sided matrix co...

  19. Integrated magnetics design for HF-link power converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper deals with the design of integrated magnetics for HF-link converters, where the integrated magnetic components do not necessarily belong to the same voltage loop. Depending on the specific HF-link converter topology, the proposed integrated magnetics can either alleviate the derivation...... of independent auxiliary supply voltages from the main transformer or integrate other magnetic structures, thus saving board space and cutting costs....

  20. Design of a DC Busbar for the ITER PF Converter

    Science.gov (United States)

    Guo, Bin; Song, Zhiquan; Xu, Liuwei; Zhang, Ming; Li, Jinchao; Jiang, Li; Fu, Peng; Wang, Min; Dong, Lin

    2014-04-01

    The DC busbar is an important component for the ITER PF converter module to connect the converter and the reactor. This paper analyzes different cross-sections and different thermodynamic properties under natural-cooling and water-cooling conditions, and simulation is carried out by the software of the finite element method (FEM). The result of the analysis shows that the water-cooling method is the better choice for the DC busbar.

  1. Design and analysis of VCSEL based twodimension wavelength converter.

    Science.gov (United States)

    Liu, H; Shum, P; Kao, M

    2003-07-14

    A novel two-dimensional vertical cavity surface emission laser (VCSEL) based wavelength converter is proposed. We developed a twodimensional transmission line laser model (TLLM) to analyze the proposed wavelength converter. This model takes into account Bragg reflectors by using the modified connecting matrix. Therefore, accurate and efficient modeling of the VCSEL structure is achieved. Extinction ratio of the output signal is investigated by considering input signal power, wavelength, facet reflectivity and cavity diameter.

  2. A Novel Circuit for Thermocouple Signals Linearization Using AD Converter

    OpenAIRE

    Ayman A. Aly; Aly S. Abo El-Lail

    2013-01-01

    A novel circuit for linearization of thermocouple signals using Analog – to – Digital converter (ADC) is proposed. The present method utilizes the ratio metric property of ADCs and the converter performs analog to digital conversion as well as linearization. The resulting circuit also has provision for scaling the linearized digital output to obtain a desired full-scale value. Computational studies carried out on the proposed method gives satisfactory results for thermocouples with monotonic ...

  3. Integrated magnetics design for HF-link power converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper deals with the design of integrated magnetics for HF-link converters, where the two integrated magnetic components on the same core do not necessarily belong to the same voltage loop. Depending on the specific HF-link converter topology, the proposed integrated magnetics can either alleviate the derivation of independent auxiliary supply voltages from the main transformer or integrate other magnetic structures, thus saving board space and cutting costs. (au)

  4. Accurate Sliding-Mode Control System Modeling for Buck Converters

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper shows that classical sliding mode theory fails to correctly predict the output impedance of the highly useful sliding mode PID compensated buck converter. The reason for this is identified as the assumption of the sliding variable being held at zero during sliding mode, effectively...... approach also predicts the self-oscillating switching action of the sliding-mode control system correctly. Analytical findings are verified by simulation as well as experimentally in a 10-30V/3A buck converter....

  5. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  6. PENGGUNAAN FUZZY LOGIC UNTUK KONTROL PARALLEL CONVERTER DC-DC

    Directory of Open Access Journals (Sweden)

    Bambang Prio Hartono

    2012-09-01

    Full Text Available Abstract: Using system fuzzy logic as control  technology have been used on low load dc-dc converter with combined parallel compiled  dc-dc converter can  obtain big load.   With existence of differrence of component parameter and each parallel compiled converter can obtained different current  and voltage output.  Function of controller  for to do adjustment, so that current which is applied  to  load by each converter  can be obtained  difference error as small as possible or same. The object of research is developing design of large signal dc-dc converter which is  combined with using  FLC so that  obtain  better performance.  To get better performance have been made plant model and simulation with CDE method.  The more systematic  system and design is needed to overcome bigger load  on dc-dc converter, so that parallel  compiled current master slave control system on dc-dc converter with using fuzzy logic  controller is used. Result of  research showed that error or difference of  current  which is applied to load can handled by fuzzy logic  controller.  Technic of current and voltage controller co to do adjustment current and voltage distribution  equally to load.  Distribution of iL1,iL2 and  output voltage Vo on dc-dc  converter with load 2,25 until  7,875 and voltage  100  until 120 volt,  load current beetwen  12 until 48, % relatif  error  Vo  0,4% until  0,9%.

  7. Experimental Study on the Langlee Wave Energy Converter

    DEFF Research Database (Denmark)

    Lavelle, John; Kofoed, Jens Peter

    This report concerns the experimental study of the 1:20 scale model of the Langlee Wave Energy Converter (WEC) carried out at Aalborg University’s wave basin during the summer of 2010.......This report concerns the experimental study of the 1:20 scale model of the Langlee Wave Energy Converter (WEC) carried out at Aalborg University’s wave basin during the summer of 2010....

  8. Advanced Catalytic Converter in Gasoline Enginer Emission Control: A Review

    OpenAIRE

    Leman A.M.; Jajuli Afiqah; Feriyanto Dafit; Rahman Fakhrurrazi; Zakaria Supaat

    2017-01-01

    Exhaust emission from automobile source has become a major contributor to the air pollution and environmental problem. Catalytic converter is found to be one of the most effective tools to reduce the overwhelming exhaust pollutants in our environment. The development of sustainable catalytic converter still remains a critical issue due to the stringent exhaust emission regulations. Another issue such as price and availability of the precious metal were also forced the automotive industry to i...

  9. Comparison of bipolar sub-modules for the alternate arm converter

    DEFF Research Database (Denmark)

    Wickramasinghe, Harith R.; Konstantinou, Georgios; Pou, Josep

    2016-01-01

    Research on dc-fault tolerant multilevel converters has gained noticeable attention over recent years. The alternate arm converter (AAC) is one of such emerging multilevel converter topologies, and a hybrid topology of the two-level converter and the modular multilevel converter (MMC). Bipolar su...... in the losses, construction, and application to the AAC, compared to FB-SM....

  10. Early Oscillation Detection for DC/DC Converter Fault Diagnosis

    Science.gov (United States)

    Wang, Bright L.

    2011-01-01

    The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.

  11. Power electronic converters modeling and control with case studies

    CERN Document Server

    Bacha, Seddik; Bratcu, Antoneta Iuliana

    2014-01-01

    Modern power electronic converters are involved in a very broad spectrum of applications: switched-mode power supplies, electrical-machine-motion-control, active power filters, distributed power generation, flexible AC transmission systems, renewable energy conversion systems and vehicular technology, among them. Power Electronics Converters Modeling and Control teaches the reader how to analyze and model the behavior of converters and so to improve their design and control. Dealing with a set of confirmed algorithms specifically developed for use with power converters, this text is in two parts: models and control methods. The first is a detailed exposition of the most usual power converter models: ·        switched and averaged models; ·        small/large-signal models; and ·        time/frequency models. The second focuses on three groups of control methods: ·        linear control approaches normally associated with power converters; ·        resonant controllers b...

  12. Coordinated Control of Wave Energy Converters Subject to Motion Constraints

    Directory of Open Access Journals (Sweden)

    Liguo Wang

    2016-06-01

    Full Text Available In this paper, a generic coordinated control method for wave energy converters is proposed, and the constraints on motion amplitudes and the hydrodynamic interaction between converters are considered. The objective of the control problem is to maximize the energy converted from ocean waves, and this is achieved by coordinating the power take-off (PTO damping of each wave energy converter in the frequency domain in each sea state. In a case study, a wave energy farm consisting of four converters based on the concept developed by Uppsala University is studied. In the solution, motion constraints, including constraints on the amplitudes of displacement and velocity, are included. Twelve months of sea states, based on measured wave data at the Lysekil test site on the Swedish west coast, are used in the simulation to evaluate the performance of the wave energy farm using the new method. Results from the new coordinated control method and traditional control method are compared, indicating that the coordinated control of wave energy converters is an effective way to improve the energy production of wave energy farm in harmonic waves.

  13. Effect of deletion polymorphism of angiotensin converting enzyme gene on progression of diabetic nephropathy during inhibition of angiotensin converting enzyme

    DEFF Research Database (Denmark)

    Parving, H H; Jacobsen, P; Tarnow, L

    1996-01-01

    showed that haemoglobin A1c concentration, albuminuria, and the double deletion genotype independently influenced the sustained rate of decline in glomerular filtration rate (R1 (adjusted) = 0.51). CONCLUSION: The deletion polymorphism in the angiotensin converting enzyme gene reduces the long term......OBJECTIVE: To evaluate the concept that an insertion/deletion polymorphism of the angiotensin converting enzyme gene predicts the therapeutic efficacy of inhibition of angiotensin converting enzyme on progression of diabetic nephropathy. DESIGN: Observational follow up study of patients...... (median 75 mg/day (range 12.5 to 150 mg/day)) that was in many cases combined with a loop diuretic, 11 patients were homozygous for the deletion allele and 24 were heterozygous or homozygous for the insertion allele of the angiotensin converting enzyme gene. MAIN OUTCOME MEASURES: Albuminuria, arterial...

  14. Early Oscillation Detection Technique for Hybrid DC/DC Converters

    Science.gov (United States)

    Wang, Bright L.

    2011-01-01

    Oscillation or instability is a situation that must be avoided for reliable hybrid DC/DC converters. A real-time electronics measurement technique was developed to detect catastrophic oscillations at early stages for hybrid DC/DC converters. It is capable of identifying low-level oscillation and determining the degree of the oscillation at a unique frequency for every individual model of the converters without disturbing their normal operations. This technique is specially developed for space-used hybrid DC/DC converters, but it is also suitable for most of commercial and military switching-mode power supplies. This is a weak-electronic-signal detection technique to detect hybrid DC/DC converter oscillation presented as a specific noise signal at power input pins. It is based on principles of feedback control loop oscillation and RF signal modulations, and is realized by using signal power spectral analysis. On the power spectrum, a channel power amplitude at characteristic frequency (CPcf) and a channel power amplitude at switching frequency (CPsw) are chosen as oscillation level indicators. If the converter is stable, the CPcf is a very small pulse and the CPsw is a larger, clear, single pulse. At early stage of oscillation, the CPcf increases to a certain level and the CPsw shows a small pair of sideband pulses around it. If the converter oscillates, the CPcf reaches to a higher level and the CPsw shows more high-level sideband pulses. A comprehensive stability index (CSI) is adopted as a quantitative measure to accurately assign a degree of stability to a specific DC/DC converter. The CSI is a ratio of normal and abnormal power spectral density, and can be calculated using specified and measured CPcf and CPsw data. The novel and unique feature of this technique is the use of power channel amplitudes at characteristic frequency and switching frequency to evaluate stability and identify oscillations at an early stage without interfering with a DC/DC converter s

  15. Digital control of grid connected converters for distributed power generation

    Energy Technology Data Exchange (ETDEWEB)

    Skjellnes, Tore

    2008-07-01

    Pulse width modulated converters are becoming increasingly popular as their cost decreases and power rating increases. The new trend of small scale power producers, often using renewable energy sources, has created new demands for delivery of energy to the grid. A major advantage of the pulse width modulated converter is the ability to control the output voltage at any point in the voltage period. This enables rapid response to load changes and non-linear loads. In addition it can shape the voltage in response to the output current to create an outward appearance of a source impedance. This is called a virtual impedance. This thesis presents a controller for a voltage controlled three phase pulse width modulated converter. This controller enables operation in standalone mode, in parallel with other converters in a micro grid, and in parallel with a strong main grid. A time varying virtual impedance is presented which mainly attenuates reactive currents. A method of investigating the overall impedance including the virtual impedance is presented. New net standards have been introduced, requiring the converter to operate even during severe dips in the grid voltage. Experiments are presented verifying the operation of the controller during voltage dips. (Author). 37 refs., 65 figs., 10 tabs

  16. Advanced Catalytic Converter in Gasoline Enginer Emission Control: A Review

    Directory of Open Access Journals (Sweden)

    Leman A.M.

    2017-01-01

    Full Text Available Exhaust emission from automobile source has become a major contributor to the air pollution and environmental problem. Catalytic converter is found to be one of the most effective tools to reduce the overwhelming exhaust pollutants in our environment. The development of sustainable catalytic converter still remains a critical issue due to the stringent exhaust emission regulations. Another issue such as price and availability of the precious metal were also forced the automotive industry to investigate the alternatives for producing a better replacement for the material used in catalytic converter. This paper aims at reviewing the present development and improvement on the catalytic converter used on the reduction of exhaust emission in order to meet the regulations and market demand. The use of new catalyst such as to replace the noble metal material of Platinum (Pt, Palladium (Pd and Rhodium (Rh has been reviewed. Material such as zeolite, nickel oxide and metal oxide has been found to effectively reduce the emission than the commercial converter. The preparation method of the catalyst has also evolved through the years as it is to ensure a good characteristic of a good monolith catalyst. Ultrasonic treatment with combination of electroplating technique, citrate method and Plasma Electrolytic Oxidation (PEO has been found as the latest novel preparation method on producing an effective catalyst in reducing the exhaust emission.

  17. Sub-picosecond Resolution Time-to-Digital Converter

    Energy Technology Data Exchange (ETDEWEB)

    Bratov, Vladimir [Advanced Science and Novel Technology Company, Rancho Palos Verdes, CA (United States); Katzman, Vladimir [Advanced Science and Novel Technology Company, Rancho Palos Verdes, CA (United States); Binkley, Jeb [Advanced Science and Novel Technology Company, Rancho Palos Verdes, CA (United States)

    2006-03-30

    Time-to-digital converters with sub-picosecond resolutions are needed to satisfy the requirements of time-on-flight measurements of the next generation of high energy and nuclear physics experiments. The converters must be highly integrated, power effective, low cost, and feature plug-and-play capabilities to handle the increasing number of channels (up to hundreds of millions) in future Department of Energy experiments. Current state-off-the-art time-to-digital converter integrated circuits do not have the sufficient degree of integration and flexibility to fulfill all the described requirements. During Phase I, the Advanced Science and Novel Technology Company in cooperation with the nuclear physics division of the Oak Ridge National Laboratory has developed the architecture of a novel time-to-digital converter with multiple channels connected to an external processor through a special interfacing block and synchronized by clock signals generated by an internal phase-locked loop. The critical blocks of the system including signal delay lines and delay-locked loops with proprietary differential delay cells, as well as the required digital code converter and the clock period counter have been designed and simulated using the advanced SiGe120 BiCMOS technological process. The results of investigations demonstrate a possibility to achieve the digitization accuracy within 1ps. ADSANTEC has demonstrated the feasibility of the proposed concept in computer simulations. The proposed system will be a critical component for the next generation of NEP experiments.

  18. Multipurpose Power Converter for Non-Grid-Connected Microsystems

    Science.gov (United States)

    Vovos, Panagis N.; Georgakas, Konstantinos G.

    2015-04-01

    The aim of this paper is to present a multipurpose converter, appropriate for non-grid-connected microsystems, which are prone to harmonic distortion. The converter suppresses harmonics by injecting mirror harmonics in the modulation stage. An important property is that it continuously monitors and significantly reduces the harmonic content without the use of active or passive low-frequency filters. This is under constant switching frequency, no matter if the harmonics are mainly created by the source, the loads or even its own operation. The converter is regulating output voltage using typical fuzzy control. The two types of control (harmonic and voltage) do not seem to affect each other during operation. Furthermore, it can supply either dc or ac loads from a dc source. The versatility of the converter is a useful property for remote or mobile micropower systems, where neither sources nor loads are of a single type. The converter has been tested successfully for a combination of harmonic-injecting electric appliances and various load step changes.

  19. On the dynamics of a novel ocean wave energy converter

    Science.gov (United States)

    Orazov, B.; O'Reilly, O. M.; Savaş, Ö.

    2010-11-01

    Buoy-type ocean wave energy converters are designed to exhibit resonant responses when subject to excitation by ocean waves. A novel excitation scheme is proposed which has the potential to improve the energy harvesting capabilities of these converters. The scheme uses the incident waves to modulate the mass of the device in a manner which amplifies its resonant response. To illustrate the novel excitation scheme, a simple one-degree of freedom model is developed for the wave energy converter. This model has the form of a switched linear system. After the stability regime of this system has been established, the model is then used to show that the excitation scheme improves the power harvesting capabilities by 25-65 percent even when amplitude restrictions are present. It is also demonstrated that the sensitivity of the device's power harvesting capabilities to changes in damping becomes much smaller when the novel excitation scheme is used.

  20. Practical aspects of plasma processes in thermionic energy converters

    Science.gov (United States)

    Rasor, N. S.; Hansen, L. K.; Fitzpatrick, G. O.; Britt, E. J.

    1975-01-01

    Over a decade of cesium vapor thermionic converter research has yielded sufficient understanding of the basic plasma processes to permit application of this understanding to improvement of converter performance. A performance index is defined which relates such converter improvements directly to increases in system performance. A prime practical objective of current research is to reduce or eliminate the arc potential drop presently required to sustain the plasma in the ignited cesium diode. This will substantially increase the energy conversion efficiency, and will permit operation at substantially lower emitter temperatures without requiring lower collector (heat rejection) temperature. Present work is concentrating on evaluating and reducing to practice the several methods employing auxiliary ion sources to eliminate the arc drop which were demonstrated over a decade ago: i.e., various ignited and unignited triode concepts, and the pulse-enhanced diode and triode. These methods are reviewed in light of present understanding and recent experimental data.