WorldWideScience

Sample records for suture closure patterns

  1. Patterns and implications of extensive heterochrony in carnivoran cranial suture closure

    Science.gov (United States)

    Goswami, A; Foley, L; Weisbecker, V

    2013-01-01

    Heterochronic changes in the rate or timing of development underpin many evolutionary transformations. In particular, the onset and rate of bone development have been the focus of many studies across large clades. In contrast, the termination of bone growth, as estimated by suture closure, has been studied far less frequently, although a few recent studies have shown this to represent a variable, although poorly understood, aspect of developmental evolution. Here, we examine suture closure patterns across 25 species of carnivoran mammals, ranging from social-insectivores to hypercarnivores, to assess variation in suture closure across taxa, identify heterochronic shifts in a phylogenetic framework and elucidate the relationship between suture closure timing and ecology. Our results show that heterochronic shifts in suture closure are widespread across Carnivora, with several shifts identified for most major clades. Carnivorans differ from patterns identified for other mammalian clades in showing high variability of palatal suture closure, no correlation between size and level of suture closure, and little phylogenetic signal outside of musteloids. Results further suggest a strong influence of feeding ecology on suture closure pattern. Most of the species with high numbers of heterochronic shifts, such as the walrus and the aardwolf, feed on invertebrates, and these taxa also showed high frequency of closure of the mandibular symphysis, a state that is relatively rare among mammals. Overall, caniforms displayed more heterochronic shifts than feliforms, suggesting that evolutionary changes in suture closure may reflect the lower diversity of cranial morphology in feliforms. PMID:23530892

  2. Cranial Suture Closure in Domestic Dog Breeds and Its Relationships to Skull Morphology.

    Science.gov (United States)

    Geiger, Madeleine; Haussman, Sinah

    2016-04-01

    Bulldog-type brachycephalic domestic dog breeds are characterized by a relatively short and broad skull with a dorsally rotated rostrum (airorhynchy). Not much is known about the association between a bulldog-type skull conformation and peculiar patterns of suture and synchondrosis closure in domestic dogs. In this study, we aim to explore breed-specific patterns of cranial suture and synchondrosis closure in relation to the prebasial angle (proxy for airorhynchy and thus bulldog-type skull conformation) in domestic dogs. For this purpose, we coded closure of 18 sutures and synchondroses in 26 wolves, that is, the wild ancestor of all domestic dogs, and 134 domestic dogs comprising 11 breeds. Comparisons of the relative amount of closing and closed sutures and synchondroses (closure scores) in adult individuals showed that bulldog-type breeds have significantly higher closure scores than non-bulldog-type breeds and that domestic dogs have significantly higher closure scores than the wolf. We further found that the prebasial angle is significantly positively correlated with the amount of closure of the basispheno-presphenoid synchondrosis and sutures of the nose (premaxillo-nasal and maxillo-nasal) and the palate (premaxillo-maxillary and interpalatine). Our results show that there is a correlation between patterns of suture and synchondrosis closure and skull shape in domestic dogs, although the causal relationships remain elusive. © 2016 Wiley Periodicals, Inc.

  3. Barbed sutures versus conventional sutures for uterine closure at cesarean section; a randomized controlled trial.

    Science.gov (United States)

    Zayed, Mohamed A; Fouda, Usama M; Elsetohy, Khaled A; Zayed, Shereef M; Hashem, Ahmed T; Youssef, Mohamed A

    2017-10-29

    The aim of this randomized control trial was to compare the operative data and the early postoperative outcomes of cesarean sections in which the uterine incision was closed with a barbed suture (STRATAFIX™ Spiral PDO Knotless Tissue Control Device, SXPD2B405, Ethicon Inc.) with those of cesarean sections in which the uterine incision was closed with a conventional smooth suture (VICRYL™; Ethicon Inc.). One hundred pregnant patients were randomized in a 1:1 ratio to the Stratafix group or the Vicryl group. The uterine incision was closed by two layers of sutures in both groups. In the Vicryl group, the first layer was continuous and the second layer was interrupted. In the Stratafix group, both layers were continuous. The uterine closure time was significantly lower in the Stratafix group (224 ± 46 versus 343 ± 75 s, p Stratafix group required additional sutures to achieve hemostasis (p value = .009). The mean blood loss during closure of uterine incision and mean hospital stay were lower in the Stratafix group but these differences failed to reach statistical significance. The use of barbed suture for uterine incision closure at cesarean section is associated with shorter uterine closure time and similar early perioperative complications compared with conventional smooth suture. The difference between both groups in the technique of suturing the second layer of the uterine incision may be the cause of the reduction in the uterine closure time and the need for additional sutures to achieve hemostasis during suturing the uterine incision with a barbed suture. Further, well designed randomized controlled trials should be conducted to investigate the association between the type of suture (barbed or conventional smooth) and remote complications of cesarean section (infertility, pelvic pain, abnormal placentation and rupture uterus).

  4. A multicenter randomized controlled trial comparing absorbable barbed sutures versus conventional absorbable sutures for dermal closure in open surgical procedures.

    Science.gov (United States)

    Rubin, J Peter; Hunstad, Joseph P; Polynice, Alain; Gusenoff, Jeffrey A; Schoeller, Thomas; Dunn, Raymond; Walgenbach, Klaus J; Hansen, Juliana E

    2014-02-01

    Barbed sutures were developed to reduce operative time and improve security of wound closure. The authors compare absorbable barbed sutures (V-Loc, Covidien, Mansfield, Massachusetts) with conventional (smooth) absorbable sutures for soft tissue approximation. A prospective multicenter randomized study comparing barbed sutures with smooth sutures was undertaken between August 13, 2009, and January 31, 2010, in 241 patients undergoing abdominoplasty, mastopexy, and reduction mammaplasty. Each patient received barbed sutures on 1 side of the body, with deep dermal sutures eliminated or reduced. Smooth sutures with deep dermal and subcuticular closure were used on the other side as a control. The primary endpoint was dermal closure time. Safety was assessed through adverse event reporting through a 12-week follow-up. A total of 229 patients were ultimately treated (115 with slow-absorbing polymer and 114 with rapid-absorbing polymer). Mean dermal closure time was significantly quicker with the barbed suture compared with the smooth suture (12.0 vs 19.2 minutes; Psutures. The rapid-absorbing barbed suture showed a complication profile equivalent to the smooth suture, while the slow-absorbing barbed suture had a higher incidence of minor suture extrusion. Barbed sutures enabled faster dermal closure quicker than smooth sutures, with a comparable complication profile. 1.

  5. New suture materials for midline laparotomy closure: an experimental study

    Science.gov (United States)

    2014-01-01

    Background Midline laparotomy closure carries a significant risk of incisional hernia. This study examines the behavior of two new suture materials, an elastic material, polyurethane (PUe), and a barbed polydioxanone (PDXb) suture thread in a rabbit model of midline incision closure. Methods Three 2-cm midline incisions were made in 68 New Zealand White rabbits. The incisions were closed by running suture using four 3/0 threads: polypropylene (PP) (Surgipro®, Covidien), PUe (Assuplus®, Assut Europe), PDX (Assufil®, Assut Europe) or PDXb (Filbloc®, Assut Europe). Animals in each suture group were euthanized 3 weeks and 6 months after surgery. Histological sections of the tissue-embedded sutures were subjected to morphological, collagen expression, macrophage response and uniaxial tensiometry studies. Results No signs of wound dehiscence or complications were observed. At 3 weeks, all sutures were surrounded by connective tissue composed mainly of collagen III. PUe showed greater collagen I expression than the other sutures. All sutures elicited a macrophage response that diminished from 3 weeks to 6 months (p sutures (PP and PUe) yet PDXb showed a significantly greater response than the other reabsorbable suture (PDX) at 3 weeks (p  0.05). Conclusion Three weeks after surgery, PUe revealed more collagen I deposition than the remaining materials and this translated to a similar biomechanical behavior to linea alba, that could avoid the appearance of short term dehiscences and thus reduce the incidence of incisional hernia. PDXb provides no additional advantages in their behavior regarding PDX suture. PMID:25231161

  6. Comparison of Subcuticular Suture Materials in Cesarean Skin Closure

    Directory of Open Access Journals (Sweden)

    Pınar Solmaz Hasdemir

    2015-01-01

    Full Text Available Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation within a 6-week period after operation. Secondary outcomes were skin closure time, the need for use of additional analgesic agent, pain score on numeric rating scale, cosmetic score, and patient scar satisfaction scale. Results. Absorbable polyglactin was used in 108 patients and nonabsorbable polypropylene was used in 142 patients. Wound complication rates were similar in primary and repeat cesarean groups based on the type of suture material. Skin closure time is longer in nonabsorbable suture material group in both primary and repeat cesarean groups. There was no difference between groups in terms of postoperative pain, need for additional analgesic use, late phase pain, and itching at the scar. Although the cosmetic results tended to be better in the nonabsorbable group in primary surgery patients, there was no significant difference in the visual satisfaction of the patients. Conclusions. Absorbable and nonabsorbable suture materials are comparable in cesarean section operation skin closure.

  7. Use of tissue adhesives versus sutures on minor surgery for incision closure: randomized controlled trial

    OpenAIRE

    Barros da Silva Pinto de Oliveira, Diogo

    2016-01-01

    Sutures, staples and adhesive tapes have been used for many years as methods of wound closure, but tissue adhesives have entered clinical practice more recently Closure of wounds with sutures enables the closure to be meticulous, but the sutures may show tissue reactivity and can require removal. Tissue adhesives offer the advantages of an absence of risk of needlestick injury and no requirement to remove sutures later. Initially, tissue adhesives were used primarily in emergency room setting...

  8. Economic evaluation of different suture closure methods: barbed versus traditional interrupted sutures.

    Science.gov (United States)

    Elmallah, Randa K; Khlopas, Anton; Faour, Mhamad; Chughtai, Morad; Malkani, Arthur L; Bonutti, Peter M; Roche, Martin; Harwin, Steven F; Mont, Michael A

    2017-12-01

    Healthcare systems are receiving increasing pressures from payers, such as the Centers for Medicare and Medicaid (CMS), to reduce the costs associated with procedures, and with the implementation of the Affordable Care Act, high costs are addressed through pay-for-performance programs. Thus, multiple areas of total knee arthroplasty (TKA) surgery are under scrutiny, including surgical times, material costs, and the costs of associated complications and readmissions. Suture type has been determined to be a factor that may influence closure times, as well as direct material costs. Therefore, the purpose of this review was to compare: (I) the cost of using barbed vs. conventional interrupted sutures; (II) the additional cost of differences in complications, if any; (III) to extrapolate cost savings on a hospital and national level; and (IV) to discuss the role of these findings on hospital savings and the effect on bundled payments. It was found that the main factors affecting differences in overall costs between barbed and standard interrupted suture were material cost and closure time. Many studies have demonstrated greater cost savings with the barbed suture due to shorter operative times, despite the higher material costs. The majority of studies also demonstrated similar complication rates between the suture types, and thus these are unlikely to affect the cost difference. However, to the best of our knowledge, there are no TKA studies in the literature evaluating the effect of suture type and associated complications on lengths of stay and readmission rates. Thus, it is unclear how these cost savings will translate to reimbursements rates and the role that they might play in bundled payments. Several studies in other specialties demonstrate decreased infection rates with the use of barbed sutures, which, if found to be true for TKA can be extrapolated to 3 million dollars of savings in revision TKA costs. Further studies on this topic are needed to define these

  9. A comparison of a new skin closure device and intradermal sutures in the closure of full-thickness surgical incisions.

    Science.gov (United States)

    Richter, Dirk; Stoff, Alexander; Ramakrishnan, Venkat; Exner, Klaus; Jernbeck, Jan; Blondeel, Phillip N

    2012-10-01

    A novel topical skin adhesive system was developed to close the outermost layer of skin in an expeditious manner. To determine its clinical utility, a clinical investigation was undertaken to demonstrate equivalence of a new adhesive skin closure system (Prineo Skin Closure System) to intradermal sutures in wound closure. The investigation included 83 patients who underwent elective abdominoplasty, circumferential body lift procedures, and breast reconstruction with deep inferior epigastric perforator flaps. Incisions were divided in half, and each half was randomized to wound closure with the new skin closure system, including a pressure-sensitive adhesive mesh tape for wound edge approximation and next-generation cyanoacrylate or intradermal sutures. Postoperative evaluations took place at 24 hours, 7 days, 12 to 25 days, 90 days, 6 months, and 12 months. The new skin closure system was found to be equivalent to intradermal sutures for the continuous approximation of wounds. The upper limit of the two-sided 90 percent confidence interval for difference in proportions was 10.9 percent. The mean time to closure for the new skin closure system was 1.46 minutes, approximately 5 minutes faster than that for intradermal sutures (p sutures for full-thickness surgical incisions with regard to safety and effectiveness. The ease and speed of application contribute to shortened operative times (4.5 times faster than intradermal sutures).

  10. Craniosynostosis of coronal suture in Twist1+/- mice occurs through endochondral ossification recapitulating the physiological closure of posterior frontal suture

    Directory of Open Access Journals (Sweden)

    Bjorn eBehr

    2011-07-01

    Full Text Available Craniosynostosis, the premature closure of cranial suture, is a pathologic condition that affects 1/2000 live births. Saethre-Chotzen syndrome is a genetic condition characterized by craniosynostosis. The Saethre-Chotzen syndrome, which is defined by loss-of-function mutations in the TWIST gene, is the second most prevalent craniosynostosis. Although much of the genetics and phenotypes in craniosynostosis syndromes is understood, less is known about the underlying ossification mechanism during suture closure. We have previously demonstrated that physiological closure of the posterior frontal (PF suture occurs through endochondral ossification. Moreover, we revealed that antagonizing canonical Wnt signaling in the sagittal suture leads to endochondral ossification of the suture mesenchyme and sagittal synostosis, presumably by inhibiting Twist1. Classic Saethre-Chotzen syndrome is characterized by coronal synostosis, and the haploinsufficient Twist1+/- mice represents a suitable model for studying this syndrome. Thus, we seeked to understand the underlying ossification process in coronal craniosynostosis in Twist1+/- mice. Our data indicate that coronal suture closure in Twist1+/- mice occurs between postnatal day 9 to 13 by endochondral ossification, as shown by histology, gene expression analysis and immunohistochemistry. In conclusion, this study reveals that coronal craniosynostosis in Twist1+/- mice occurs through endochondral ossification. Moreover, it suggests that haploinsufficency of Twist1 gene, a target of canonical Wnt-signaling, and inhibitor of chondrogenesis, mimics conditions of inactive canonical Wnt-signaling leading to craniosynostosis.

  11. Comparison of suture types in the closure of scalp wounds.

    LENUS (Irish Health Repository)

    Bonham, Joseph

    2011-06-01

    Innovation in practice can benefit patients and healthcare providers but must be evidence based. This article describes a quantitative study of whether absorbable sutures are as beneficial as non-absorbable sutures in the management of simple scalp lacerations in adults. The results suggest that absorbable sutures can provide the same cosmetic and functional results as non-absorbable sutures. Their use can also reduce patient returns and save money and resources.

  12. Comparative Study Between Coaptive Film Versus Suture For Wound Closure After Long Bone Fracture Fixation

    Directory of Open Access Journals (Sweden)

    IM Anuar Ramdhan

    2013-03-01

    Full Text Available INTRODUCTION: Coaptive film (i.e., Steri-StripsTM is an adhesive tape used to replace sutures in wound closure. The use of coaptive film for wound closure after long bone fracture fixation has not been well documented in the literature. METHODS: The aim of this prospective, randomized controlled trial comparing coaptive film with sutures for wound closure after long bone fracture fixation was skin closure time, incidence of wound complications and scar width at 12 week follow-up. Forty-five patients underwent femur fracture fixation (22 patients’ wound closed with sutures, 23 with coaptive film. RESULTS: The mean time for skin closure using coaptive film was 171.13 seconds compared to 437.27 seconds using suture. The mean wound lengths in the coaptive film group and suture group were 187.65 mm and 196.73 mm, respectively. One patient in each group had wound complications. CONCLUSION: Coaptive film is a time-saving procedure for skin closure following long bone fracture fixation. There is no difference in the incidence of wound complications and scar width between these two methods of skin closure.

  13. Percutaneous closure of a left atrial appendage with relevant suture dehiscence.

    Science.gov (United States)

    Kleinebrecht, L; Veulemans, V; Polzin, A; Kelm, M; Zeus, T

    2017-02-01

    Atrial fibrillation is a widespread disease and highly relevant as it carries an extended risk for ischaemic stroke. Surgical closure of the left atrial appendage is routinely performed during open heart surgery in patients with atrial fibrillation with the aim of thromboembolic protection. In this report we present a successful percutaneous closure of a left atrial appendage, which showed clinically relevant suture dehiscence several years after surgical closure.

  14. Suture Closure versus Non-Closure of Subcutaneous Fat and Cosmetic Outcome after Cesarean Section: A Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Heinrich Husslein

    Full Text Available To investigate the effect of subcutaneous fat suture closure versus non-closure at cesarean section (CS on long-term cosmetic outcome.Women undergoing planned or unplanned CS were randomized to either subcutaneous fat suture closure or non-closure using a 1∶1 allocation algorithm. Participants and outcome assessors were blinded to group allocation. Scar evaluation was performed after two and six months. Primary outcome measures were Patient and Observer Scar Assessment Scale (POSAS summary scores six months after surgery. Secondary outcome measures were Vancouver Scar Scale (VSS summary scores, retraction of the scar below the level of the surrounding skin, duration of surgery, and development of hematoma, seroma, surgical site infection (SSI or wound disruption. Data were analyzed according to the intention to treat principle.A total of 116 women were randomized and 91 participants, 47 in the closure and 44 in the non-closure group, completed the trial and were analyzed. There were no differences in patient morphometrics or surgery indications between groups. At two and six months no significant differences were found with respect to POSAS or VSS scores between groups. After two months significantly more women in the non-closure group described their scar as being retracted below the level of the skin (36% vs. 15%, p = 0.02 whereas no difference was observed at six months. There were significantly more hematomas in the non-closure (25% compared to the closure group (4% (p = 0.005. There was no difference in duration of surgery, SSI, seroma formation or wound disruption between groups.Suture closure of the subcutaneous fat at CS does not affect long-term cosmetic outcome. (Level I evidence.ClinicalTrials.gov NCT01542346.

  15. The Role of Barbed Sutures in Wound Closure Following Knee and Hip Arthroplasty: A Review.

    Science.gov (United States)

    Faour, Mhamad; Khlopas, Anton; Elmallah, Randa K; Chughtai, Morad; Kolisek, Frank R; Barrington, John W; Mont, Michael A

    2018-01-02

    Lower extremity joint arthroplasty procedures often require a large incision to have an adequate exposure, which subsequently leads to lengthy wounds that may contribute to long closure, anesthesia, and overall operative times. The recently introduced knotless barbed suture may provide better outcomes, faster closure time, and decreased material utilization. Therefore, the aim of this study was to review the impact of barbed sutures on: (1) wound-related complications; (2) closure and operative time; (3) patient outcomes (range of motion and Knee Society Scores [KSS]); and (4) effects on cosmesis and patients' satisfaction. A literature search was performed using up to February 2017. Barbed sutures were associated with shorter closure times, shorter operative times, and larger cost savings per procedure as well as comparable wound complication rates after total joint arthroplasty. Although the current review is limited by the number of studies included, it demonstrates that overall, barbed sutures contribute to surgical efficiency when compared with conventional skin closure modalities. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Water-tight knee arthrotomy closure: comparison of a novel single bidirectional barbed self-retaining running suture versus conventional interrupted sutures.

    Science.gov (United States)

    Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred

    2011-03-01

    Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.

  17. Ameloblastin inhibits cranial suture closure by modulating MSX2 expression and proliferation.

    Directory of Open Access Journals (Sweden)

    Phimon Atsawasuwan

    Full Text Available Deformities of cranial sutures such as craniosynostosis and enlarged parietal foramina greatly impact human development and quality of life. Here we have examined the role of the extracellular matrix protein ameloblastin (Ambn, a recent addition to the family of non-collagenous extracellular bone matrix proteins, in craniofacial bone development and suture formation. Using RT-PCR, western blot and immunohistochemistry, Ambn was localized in mouse calvarial bone and adjacent condensed mesenchyme. Five-fold Ambn overexpression in a K14-driven transgenic mouse model resulted in delayed posterior frontal suture fusion and incomplete suture closure. Moreover, Ambn overexpressor skulls weighed 13.2% less, their interfrontal bones were 35.3% thinner, and the width between frontal bones plus interfrontal suture was 14.3% wider. Ambn overexpressing mice also featured reduced cell proliferation in suture blastemas and in mesenchymal cells from posterior frontal sutures. There was a more than 2-fold reduction of Msx2 in Ambn overexpressing calvariae and suture mesenchymal cells, and this effect was inversely proportionate to the level of Ambn overexpression in different cell lines. The reduction of Msx2 expression as a result of Ambn overexpression was further enhanced in the presence of the MEK/ERK pathway inhibitor O126. Finally, Ambn overexpression significantly reduced Msx2 down-stream target gene expression levels, including osteogenic transcription factors Runx2 and Osx, the bone matrix proteins Ibsp, ColI, Ocn and Opn, and the cell cycle-related gene CcnD1. Together, these data suggest that Ambn plays a crucial role in the regulation of cranial bone growth and suture closure via Msx 2 suppression and proliferation inhibition.

  18. Surgical staples compared with subcuticular suture for skin closure after cesarean delivery: a randomized controlled trial.

    Science.gov (United States)

    Figueroa, Dana; Jauk, Victoria Chapman; Szychowski, Jeff M; Garner, Rachel; Biggio, Joseph R; Andrews, William W; Hauth, John; Tita, Alan T N

    2013-01-01

    To compare the risk of cesarean wound disruption or infection after closure with surgical staples compared with subcuticular suture. Women with viable pregnancies at 24 weeks of gestation or greater undergoing scheduled or unscheduled cesarean delivery were randomized to wound closure with surgical staples or absorbable suture. Staples were removed at postoperative days 3-4 for low transverse incisions and days 7-10 for vertical incisions. Standardized wound evaluations were performed at discharge (days 3-4) and 4-6 weeks postoperatively. The primary outcome was a composite of wound disruption or infection within 4-6 weeks. Secondary outcomes included operative time, highest pain score on analog scale, cosmesis score, and patient scar satisfaction score. Analyses were by intent to treat. Of 398 patients, 198 were randomized to staples and 200 to suture (but four received staples). Baseline characteristics including body mass index, prior cesarean delivery, labor, and type of skin incision were similar by group. The primary outcome incidence at hospital discharge was 7.1% for staples and 0.5% for suture (Psuture (P=.008, relative risk 2.5, 95% CI 1.2-5.0). Operative time was longer with suture closure (median time of 58 versus 48 minutes; Psuture is associated with significantly increased composite wound morbidity after cesarean delivery. : ClinicalTrials.gov, www.clinicaltrials.gov, NCT01008449. : I.

  19. Diagonal tarsal suture technique sine marginal sutures for closure of full-thickness eyelid defects.

    Science.gov (United States)

    Willey, Andrea; Caesar, Richard H

    2013-01-01

    Precise apposition of the tarsal plates and meticulous alignment of the eyelid margins are essential to ensure a seamless repair and avoid notching of the eyelid margin. The authors present a simple and reliable technique that firmly apposes and precisely aligns the eyelid margin in the x, y, and z axes, obviating the need for marginal sutures. A retrospective audit of electronic medical records was performed for all patients who underwent reconstructive procedures that included the repair of a full-thickness defect in the eyelid margin using the diagonal suture technique from 2003 to 2012. Of the 652 surgeries performed in the past 9 years, 9 incidences of notching occurred, all of which were associated with infections. The diagonal tarsal suture technique is a simple and effective method for the repair of full-thickness defects with a high degree of patient satisfaction.

  20. Fast Absorbing Gut Suture versus Cyanoacrylate Tissue Adhesive in the Epidermal Closure of Linear Repairs Following Mohs Micrographic Surgery

    OpenAIRE

    Kim, June; Singh Maan, Harjot; Cool, Alicia J.; Hanlon, Allison M.; Leffell, David J.

    2015-01-01

    Background: Cyanoacrylate topical adhesives and fast absorbing gut sutures are increasingly utilized by dermatologic surgeons as they provide satisfactory surgical outcomes while eliminating an additional patient visit for suture removal. To date, no head-to-head studies have compared the wound healing characteristics of these epidermal closure techniques in the repair of facial wounds after Mohs micrographic surgery. Objective: To compare the cosmetic outcome of epidermal closure by cyanoacr...

  1. Fast Absorbing Gut Suture versus Cyanoacrylate Tissue Adhesive in the Epidermal Closure of Linear Repairs Following Mohs Micrographic Surgery.

    Science.gov (United States)

    Kim, June; Singh Maan, Harjot; Cool, Alicia J; Hanlon, Allison M; Leffell, David J

    2015-02-01

    Cyanoacrylate topical adhesives and fast absorbing gut sutures are increasingly utilized by dermatologic surgeons as they provide satisfactory surgical outcomes while eliminating an additional patient visit for suture removal. To date, no head-to-head studies have compared the wound healing characteristics of these epidermal closure techniques in the repair of facial wounds after Mohs micrographic surgery. To compare the cosmetic outcome of epidermal closure by cyanoacrylate topical adhesive with fast absorbing gut suture in linear repairs of the face following Mohs micrographic surgery. Fourteen patients with wound length greater than 3cm who underwent Mohs micrographic surgery for nonmelanoma skin cancer of the face were enrolled in this randomized right-left comparative study. Following placement of dermal sutures, half of the wound was randomly selected for closure with cyanoacrylate and the contralateral side with fast absorbing gut suture. Using photographs from the three-month postoperative visit, six blinded individuals rated the overall cosmetic outcome. The present study shows no significant difference in cosmetic outcomes between cyanoacrylate and fast absorbing gut suture for closure of linear facial wounds resulting from Mohs micrographic surgery. Cyanoacrylate tissue adhesive may not be as effective in achieving optimal cosmesis for wounds on the forehead or of longer repair lengths. The majority of patients did not have a preference for wound closure techniques, but when a preference was given, cyanoacrylate was significantly favored over sutures. Cyanoacrylate tissue adhesive and fast absorbing gut suture both result in comparable aesthetic outcomes for epidermal closure of linear facial wounds following Mohs micrographic surgery. Consideration should be given to factors such as need for eversion, hemostasis, and wound tension when selecting an epidermal wound closure method. (ClinicalTrials.gov, Identifier: NCT01298167, http

  2. A new mathematical model for pattern formation by cranial sutures.

    Science.gov (United States)

    Yoshimura, Kenji; Kobayashi, Ryo; Ohmura, Tomohisa; Kajimoto, Yoshinaga; Miura, Takashi

    2016-11-07

    Cranial sutures are narrow mesenchymal tissues that connect skull bones to each other. Given that they serve as growth centers in the skull, these undifferentiated tissues play crucial roles in skull development. Cranial sutures are also of clinical importance, because the premature fusion of skull bones results in a pathological condition called craniosynostosis. In newborns, skull sutures are wide and straight; during adolescence, they become thinner and start winding to form an interdigitating pattern. From a functional aspect, as the degree of interdigitation becomes larger, the strength of the connection between bones increases. However, the mechanisms underlying the maintenance of mesenchymal narrow bands or formation of interdigitation remain poorly understood. In the present study, we presented a new mathematical model that can reproduce the suture width maintenance and interdigitation formation. We can predict the width of the mesenchyme bands and wavelengths of suture interdigitations from the model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Temporary closure of colostomy with suture before colostomy takedown improves the postoperative outcomes.

    Science.gov (United States)

    Hu, Wan-Hsiang; Lee, Ko-Chao; Tsai, Kai-Lung; Chen, Hong-Hwa

    2018-01-01

    Temporary loop colostomy is a common surgical procedure used to avoid complications in high-risk distal anastomosis as well as pelvic inflammation. Issues regarding postoperative outcomes of colostomy takedown have been widely discussed in the literature, wound infection especially. Temporary closure of colostomy with suture before takedown was adopted in our study, which provided excellent traction to aid mobilization of stomy and avoided stool spillage to downgrade the wound classification to "clean contamination." We aimed to determine the effects of the procedure on postoperative outcomes. This was a prospective case-control study at a single tertiary medical center. Patients presenting for elective colostomy takedown were included. Allis clamp (n = 50) or silk suture (n = 60) was applied to mobilize the colostomy, and results were compared. Operative time and wound infection rate were measured as primary postoperative outcomes. Univariate and multivariate analyses were used to demonstrate the association between the two groups and outcomes. In univariate analyses, significantly shorter operative time (median = 57 min, p = 0.003) and lower postoperative wound infection rate (3%, p = 0.03) were noted in the group receiving silk suture. Multivariate analyses results showed that silk suture was significantly associated with both operative time (B = - 8.5, p = 0.01) and wound infection (odds ratio = 0.18, p = 0.04). With the advantage of enhancing traction and decreasing contamination, the temporary closure of colostomy with suture improved takedown outcomes, including a shorter operative time and lower wound infection rate.

  4. Sutures versus staples for wound closure in orthopaedic surgery: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Shantz Jesse A

    2012-06-01

    Full Text Available Abstract Background A recently published meta-analysis comparing metallic staples to sutures in orthopaedic procedures revealed three fold increase in risk for infection in stapled wounds. The studies included in the meta-analysis are at risk of bias due to experimental design limitations. A large randomized controlled trial is proposed to direct orthopaedic surgeons in their choice of wound closure material. Methods/Design A parallel group randomized controlled trial with institutional review board approval will be conducted. Patients will be randomized intraoperatively to have skin wounds closed with sutures or staples. Dressings will be used to maintain blinding outcome assessors. The primary outcome measure will be a composite all-cause wound complication outcome measure composed of: infection, wound drainage, wound necrosis, blistering, dehiscence, suture abscess and material sensitivity reaction. An independent review board blinded to treatment assignment will adjudicate suspected complications based on clinical data. All deceased patients will also be reviewed. An interim analysis of complications will take place after half of the patients have been recruited. All data will be analyzed by a blinded statistician. Dichotomous primary and secondary outcome measures will be analyzed using the Chi-squared statistic. Continuous outcome measures will be analyzed using Student's t-test. Subgroup analysis will compare infection rates using sutures versus staples in each anatomic area (upper extremity, pelvis/acetabulum, hip/femur, knee, ankle. A further subgroup analysis will be conducted comparing trauma patients to elective surgery patients. Non-infected revision surgery will also be compared to primary surgery. Discussion Wound closure material is an afterthought for many orthopaedic surgeons. The combined results of several comparative trials suggests that the choice of wound closure materials may have an impact on the rate of surgical site

  5. Sutures versus staples for wound closure in orthopaedic surgery: a randomized controlled trial.

    Science.gov (United States)

    Shantz, Jesse A; Vernon, James; Leiter, Jeff; Morshed, Saam; Stranges, Gregory

    2012-06-06

    A recently published meta-analysis comparing metallic staples to sutures in orthopaedic procedures revealed three fold increase in risk for infection in stapled wounds. The studies included in the meta-analysis are at risk of bias due to experimental design limitations. A large randomized controlled trial is proposed to direct orthopaedic surgeons in their choice of wound closure material. A parallel group randomized controlled trial with institutional review board approval will be conducted. Patients will be randomized intraoperatively to have skin wounds closed with sutures or staples. Dressings will be used to maintain blinding outcome assessors. The primary outcome measure will be a composite all-cause wound complication outcome measure composed of: infection, wound drainage, wound necrosis, blistering, dehiscence, suture abscess and material sensitivity reaction. An independent review board blinded to treatment assignment will adjudicate suspected complications based on clinical data. All deceased patients will also be reviewed. An interim analysis of complications will take place after half of the patients have been recruited. All data will be analyzed by a blinded statistician. Dichotomous primary and secondary outcome measures will be analyzed using the Chi-squared statistic. Continuous outcome measures will be analyzed using Student's t-test. Subgroup analysis will compare infection rates using sutures versus staples in each anatomic area (upper extremity, pelvis/acetabulum, hip/femur, knee, ankle). A further subgroup analysis will be conducted comparing trauma patients to elective surgery patients. Non-infected revision surgery will also be compared to primary surgery. Wound closure material is an afterthought for many orthopaedic surgeons. The combined results of several comparative trials suggests that the choice of wound closure materials may have an impact on the rate of surgical site infections. However, the strength of the evidence is poor given

  6. An in vivo comparison of barbed suture devices and conventional monofilament sutures for cosmetic skin closure: biomechanical wound strength and histology.

    Science.gov (United States)

    Zaruby, Jeffrey; Gingras, Kristen; Taylor, Jack; Maul, Don

    2011-02-01

    Very little biomechanical or histological data exist in the peer-reviewed literature comparing absorbable monofilament sutures to commercially-available knotless, absorbable barbed suture devices for cosmetic closure of skin incisions. The authors compare two commercially-available knotless, barbed suture devices against a conventional monofilament suture in a porcine model for biomechanical wound strength and histological quality of healing. This prospective randomized trial included 18 animals randomly assigned among three groups, with six in each. A total of 192 incisions were closed in a porcine in vivo model and assessed for biomechanical strength and histology at postoperative Days 0, 3, 10, and 21. Each animal received all three test devices in a randomized, three-way matched design. Immediately following euthanasia, the skin incisions were excised for ex vivo biomechanical testing. In the ex vivo analysis, Biosyn proved significantly stronger than the V-Loc 90 device at Day 0 and Quill Monoderm at Day 3. At no time point was there any difference in biomechanical strength between the two barbed suture devices. Differences in barb geometry, barb number, and helicity between the two barbed suture devices resulted in failure modes that were significantly different. All three test articles resulted in mild tissue reaction scores on histology. The V-Loc 90 device consistently had the lowest tissue reaction scores at all time periods, with the difference between the V-Loc 90 device and Quill being significant at postoperative Day 10. Knotless, absorbable barbed suture devices are a safe and efficacious alternative for cosmetic skin closures and yield wound strength and tissue reaction scores that are comparable to those from closures performed with absorbable monofilament sutures and secured with knots.

  7. [Water-tight closure of spinal dura with a new clot suture technique (author's transl)].

    Science.gov (United States)

    Matras, H; Jesch, W; Kletter, G; Dinges, H P

    1978-06-09

    A new clot-suturing Technique (using high-concentration fibrinogen solutions) for water-tight closure of the dura is reported. Six dogs underwent laminectomy of the thoracic spine with medial longitudinal incision in the chordal dura. After the dural split had been sealed with natural tissue adhesive and closure of the wound in layers, the animals were sacrificed at intervals of 1 to 21 days postoperatively and the chordal segments involved were removed and histologically examined. Early fibrinolysis of the clot was prevented by adding a natural proteinase inhibitor and factor XIII concentrate to the clotting substances. Histological analysis showed that healing was almost complete after 2 weeks, with delicate connective tissue overgrowing the dural split. After complete reabsorption of fibrin, the originally abundant absorbent granulation tissue had largely disappeared. Among the satisfactory results of fibrin suturing are optimum healing tendency in the fibrin-sutured region, absence of tissue irritation and neurotoxicity, which are known attributes of the synthetic alkl-cyano-acrylate tissue adhesives.

  8. Tacks, staples, or suture: method of peritoneal closure in laparoscopic transabdominal preperitoneal inguinal hernia repair effects early quality of life.

    Science.gov (United States)

    Ross, Samuel W; Oommen, Bindhu; Kim, Mimi; Walters, Amanda L; Augenstein, Vedra A; Heniford, B Todd; Todd Heniford, B

    2015-07-01

    TAPP inguinal hernia repair (IHR) entails the development of a peritoneal flap (PF) in order to reduce the hernia sac and create a preperitoneal space in which to place mesh. Many methods for closure of the PF exist including sutures, tacks, and staples. We hypothesized that patients who had PF closure with suture would have better short-term QOL outcomes. A prospective institutional hernia-specific database was queried for all adult, TAPP IHRs from July 2012 to August 2013. Unilateral and bilateral patients were included and each hernia was analyzed separately. The main outcome of interest was quality of life (QOL) at two- and four-week follow-up, as measured by the Carolinas Comfort Scale. There were 227 patients who underwent TAPP, with 99 bilateral and 128 unilateral IHR, for a total of 326 IHR. PF closure was performed using tacks in 45.1%, suture in 19.0%, and staples in 35.9%. Patient characteristics were statistically similar between the tack, suture, and staple group. There were 32.9% direct, 46.5% indirect, and 20.6% pantaloon hernias, which were not significantly different when compared by PF closure method. Post-operative complications and length of stay were same for the three groups. There were no hernia recurrences. Post-operative activity limitation at two weeks was significantly better in the suture group when compared to the stapled group (p = 0.005). Additionally, sutured PF closure had less early post-operative pain when compared to the tack group (p = 0.038). Following TAPP IHR, suture closure of the PF significantly improves 2-week post-operative movement limitation compared to stapled and tacked PF closure. Continued randomized studies are needed to determine the best surgical hernia repair methods for ideal post-op QOL.

  9. Evaluation of four suture materials for surgical incision closure in Siberian sturgeon

    Science.gov (United States)

    Boone, S. Shaun; Hernandez, Sonia M.; Camus, Alvin C.; Peterson, Douglas C.; Jennings, Cecil A.; Shelton, James L.; Divers, Stephen J.

    2015-01-01

    The visual and microscopic tissue reactions to the absorbable monofilament Monocryl, absorbable monofilament triclosan-coated Monocryl-Plus, absorbable multifilament Vicryl, and nonabsorbable monofilament Prolene were evaluated for their use of surgical closure in Siberian Sturgeon Acipenser baerii. Postoperative assessments were conducted at 1, 2, 8, 12, and 26 and 55 weeks to visually evaluate the surgical incision for suture retention, incision healing, erythema, and swelling. Incisions were also assessed microscopically at 1, 2, and 8 weeks for necrosis, inflammation, hemorrhage, and fibroplasia. The results indicated that incisions closed with either Vicryl or Prolene suture materials were more likely to exhibit more erythema or incomplete healing compared with those closed with Monocryl or Monocryl-Plus. The surgical implantation of a transmitter in the coelomic cavity did not significantly affect the response variables among the four suture materials. Monocryl or Monocryl-Plus were equally effective and superior to other suture materials used for closing surgical incisions in Siberian Sturgeon or closely related species of sturgeon. Furthermore, Monocryl or Monocryl-Plus may decrease the risk of transmitter expulsion through the incision, as surgical wounds appear to heal faster and exhibit less erythema compared with those closed with Vicryl.

  10. CLOSURE TIME OF SPHENO-OCCIPITAL SUTURE IN THE MALE CADAVERS REFERRED TO LEGAL MEDICINE ORGANIZATION

    Directory of Open Access Journals (Sweden)

    M. Akhlaghi

    2008-05-01

    Full Text Available The identity of dead is an essential part of post-mortem examination. The identification of unknown human remnants begins with the creation of an anthropological profile, which includes sex, biological age, stature and individualizing features. The estimation of age at death is based on the bodily biological changes that occur throughout life. Closure of spheno occipital synchondrosis is one of factors used for age estimation although its importance and reliability has been challenged with different authors. We studied its closure time among Iranian 8 to 26 years old male cadavers with direct inspection during autopsy. We divided synchondrosis situation depending on its fusion state into three categories: open, semi closed and closed. During 2004-5, 106 cases studied. Mean age of open, semi closed and closed were 12.78, 16.86 and 21.36 years, respectively. Their difference was significant (p< 0.05. Partial fusion (semi closed was seen at 12 years while complete fusion (closed should be 15 years or above. Spearman's correlation ratio coefficient showed linear correlation between age and suture situation (rho = 0.684, P < 0.05. Our results showed that closure of spheno occipital suture can be used as a good indicator for age estimation in males. With sensitivity of 88.31% and specificity of 79.31% males can be correctly grouped above or below 16 years.

  11. A randomized study comparing traditional monofilament knotted sutures with barbed knotless sutures for donor leg wound closure in coronary artery bypass surgery.

    Science.gov (United States)

    Krishnamoorthy, Bhuvaneswari; Shepherd, Niamh; Critchley, William R; Nair, Janesh; Devan, Nehru; Nasir, Abdul; Barnard, James B; Venkateswaran, Rajamiyer V; Waterworth, Paul D; Fildes, James E; Yonan, Nizar

    2016-02-01

    Surgical knots on the suture line provide an anchoring function, but also represent a potential source of infection and irritation on the donor leg after coronary artery bypass surgery. Knotless barbed sutures were designed to prevent knot-related complications. This study compared knot-related wound complication rates between patients receiving traditional monofilament sutures and those receiving barbed knotless sutures for closure of the donor leg. One hundred and forty-two patients were randomized into two groups. Group 1 (n = 70) received traditional monofilament sutures and Group 2 (n = 72) received barbed knotless sutures. All wounds were assessed on postoperative days 3 and 5 and weeks 2, 4 and 6 using a validated wound scoring system. Antibiotics usage and general practitioner and district nurse visits were recorded. No demographic differences were observed between groups. Leg wound skin closure times were significantly shorter in Group 2 compared with Group 1 (P adverse skin tissue reactions (P adverse skin tissue reactions that may delay postoperative wound healing. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Endoscopic suturing versus endoscopic clip closure of the mucosotomy during a per-oral endoscopic myotomy (POEM): a case-control study.

    Science.gov (United States)

    Pescarus, Radu; Shlomovitz, Eran; Sharata, Ahmed M; Cassera, Maria A; Reavis, Kevin M; Dunst, Christy M; Swanström, Lee L

    2016-05-01

    Obtaining an adequate mucosal closure is one of the crucial steps in per-oral endoscopic myotomy (POEM). Thus far, there have been no objective data comparing the various available closure techniques. This case-controlled study attempts to compare the application of endoscopic clips versus endoscopic suturing for mucosotomy closure during POEM cases. A retrospective review of our prospective POEM database was performed. All cases in which endoscopic suturing was used to close the mucosotomy were matched to cases in which standard endoclips were used. Overall complication rate, closure time and mucosal closure costs between the two groups were compared. Both techniques offer good clinical results with good mucosal closure and the absence of postoperative leak. Closure time was significantly shorter (p = 0.044) with endoscopic clips (16 ± 12 min) when compared to endoscopic suturing (33 ± 11 min). Overall, the total closure cost analysis showed a trend toward lower cost with clips (1502 ± 849 USD) versus endoscopic suturing (2521 ± 575 USD) without reaching statistical significance (p = 0.073). The use of endoscopic suturing seems to be a safe method for mucosal closure in POEM cases. Closure time is longer with suturing than conventional closure with clips, and there is a trend toward higher overall cost. Endoscopic suturing is likely most cost-effective for difficult cases where conventional closure methods fail.

  13. Is There an Advantage to Knotless Barbed Suture in TKA Wound Closure? A Randomized Trial in Simultaneous Bilateral TKAs.

    Science.gov (United States)

    Sah, Alexander P

    2015-06-01

    Effective wound closure is critical to minimizing wound complications and withstanding the forces associated with early knee motion after TKA. Barbed sutures allow for knotless fixation, have been used successfully in other specialties, and may provide for more even distribution of tension along the length of the incision; however, data regarding unidirectional barbed sutures from randomized trials have raised important concerns about their use. Bidirectional barbed sutures offer a potential alternative, but have not been studied extensively in orthopaedic surgery. Using a prospective, randomized, within-patient controlled study design I compared wound closure performed with bidirectional barbed sutures in one knee of bilateral TKAs performed under the same anesthetic with those performed with standard sutures in the other knee to determine whether the barbed suture was associated with (1) faster closure times; (2) fewer intraoperative suture issues, such as needle sticks or suture breakage, and fewer postoperative wound complications; (3) no detrimental effect on clinical outcomes, including knee ROM and Knee Society scores; and (4) lower total operative cost, considering suture material cost and operating room time savings. Between 2011 and 2012, 50 consecutive patients meeting prespecified inclusion criteria with simultaneous bilateral TKAs had deep and superficial closures performed using interrupted and running standard sutures in one randomly assigned knee, and running knotless bidirectional barbed sutures in the other knee. The barbed suture is US FDA-approved for soft tissue approximation wherever absorbable sutures are appropriate. Intraoperative suture issues and the number of sutures used were recorded at the time of wound closure. Suture cost was compared between the standard and barbed sutures and measured against the operative time cost, as estimated per minute saved. Patients were followed postoperatively at 2, 6, and 12 weeks, and 1 year. Outcomes

  14. Absorbable versus non-absorbable sutures for skin closure after carpal tunnel decompression surgery.

    Science.gov (United States)

    Wade, Ryckie G; Wormald, Justin Cr; Figus, Andrea

    2018-02-01

    Carpal tunnel syndrome is a common problem and surgical decompression of the carpal tunnel is the most effective treatment. After surgical decompression, the palmar skin may be closed using either absorbable or non-absorbable sutures. To date, there is conflicting evidence regarding the ideal suture material and this formed the rationale for our review. To assess the effects of absorbable versus non-absorbable sutures for skin closure after elective carpal tunnel decompression surgery in adults on postoperative pain, hand function, scar satisfaction, wound inflammation and adverse events. We searched the following databases on 30 October 2017: the Cochrane Neuromuscular Specialised Register, CENTRAL, MEDLINE, and Embase. We searched two clinical trials registries on 30 October 2017. We considered all randomised or quasi-randomised controlled trials comparing absorbable and non-absorbable sutures for skin closure after any form of carpal tunnel decompression surgery in adults. The unit of analysis was the hand rather than the patient. We performed meta-analysis of direct comparisons to generate standardised mean differences (SMDs) with 95% confidence intervals (CIs) in pain scores and risk ratios (RRs) with 95% CIs for dichotomous outcomes, such as wound inflammation. The primary outcome was postoperative pain. Secondary outcomes included hand function, scar satisfaction, scar inflammation and adverse events (complications). We assessed the quality of evidence for key outcomes using GRADE. We included five randomised trials (255 participants). The trials were all European (UK, Republic of Ireland, Denmark and the Netherlands). Where quoted, the mean age of participants was between 48 and 53 years. The trials measured outcomes between one and 12 weeks postoperatively.Meta-analysis of postoperative pain scores for absorbable versus non-absorbable sutures at 10 days following open carpal tunnel decompression (OCTD) produced a SMD of 0.03 (95% CI -0.43 to 0.48; 3

  15. Suture patterns and corneal graft rotation in the cadaver eye.

    Science.gov (United States)

    Au, Y K; Mahjoub, S B; Hart, J C

    1990-07-01

    Torque and antitorque running sutures as described by Eisner are commonly used in penetrating keratoplasty. We tested the rotational effect of three different 16-bite running suture patterns on eight cadaver eyes, with the following results: (1) the torque pattern rotates the corneal graft counterclockwise by 0.7 +/- 0.1 mm at the wound or 11 degrees; (2) the antitorque pattern rotates the corneal graft clockwise by 0.7 +/- 0.1 mm at the wound or 11 degrees; (3) an intermediate "no torque" pattern, the bites of which form an isosceles triangle, produces no rotational effect. We recommend the use of a "no torque" pattern to minimize corneal graft rotation.

  16. A novel method for endoscopic perforation management by using abdominal exploration and full-thickness sutured closure.

    Science.gov (United States)

    Kumar, Nitin; Thompson, Christopher C

    2014-07-01

    Perforation of the GI tract during endoscopy can result in significant morbidity and mortality. Early recognition and immediate management of endoscopic perforation are essential to optimize outcome. Larger perforations, defects with complex geometry, and those complicated by leakage of luminal contents have traditionally required surgical management. To assess the feasibility of a new method for managing complex perforations that incorporates abdominal exploration and endoscopic sutured closure. Case series. Tertiary care center. Two patients with large, complicated perforations and peritoneal contamination. Endoscopic exploration of abdomen with angiocatheter placement under direct visualization, management of leaked luminal contents, and full-thickness sutured defect closure. Endoscopic abdominal exploration through the perforation site allowed safe placement of an angiocatheter for management of pneumoperitoneum, inspection for injury that may warrant surgical management, and removal of leaked luminal contents. Endoscopic sutured closure allowed safe and robust perforation management. Repair of gastrojejunal anastomotic perforation required 2 sutures and 63 minutes. Repair of gastric perforation required 4 sutures and 48 minutes. Patients had successful endoscopic defect closure confirmed by an upper GI series and were discharged 1 day later. Report of a new method in 2 patients performed at tertiary care center. We demonstrate successful management of complex perforations with peritoneal contamination by incorporating endoscopic exploration and sutured closure with standard treatment measures. Traditional practice would have directed these patients to surgical management, which introduces additional morbidity and cost. A means for safe and broad implementation of these techniques should be evaluated. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Power scaling of ammonitic suture patterns from the suborder Ancyloceratina

    Science.gov (United States)

    Peterman, D. J.; Barton, C. C.

    2016-12-01

    The spatial scaling of suture patterns from 44 ammonite species of the suborder Ancyloceratina was measured using the fractal box counting method. These specimens were selected from every stage in the Cretaceous and range between approximately 145 Ma to 66 Ma in age. The sutures analyzed in this study were found from published literature where half of the three dimensional paths along the last septal margins were projected on a two dimensional surface. The fractal dimension calculated from the suture patterns ranges from 1.23 to 1.58. These values positively correlate to whorl height (the length between the venter and umbilicus through a transverse cross-section at the last septum of an adult specimen) with a least squares regression analysis correlation coefficient r = 0.617. The fractal dimensions of Cretaceous sutures from Ancyloceratina were compared to a study by Olóriz et al. (2002) where fractal dimensions were measured for suture patterns of 280 species of Late Jurassic ammonites. They found a significant positive correlation (r = 0.500) between fractal dimension and whorl height but only for neritic species (ammonites that inhabit the shallow domain before the drop off of the continental shelf), and a less significant relationship (r = 0.148) for epioceanic species (that occupy the zone beyond the drop off of the continental shelf). Of the 44 sutures from Ancyloceratina analyzed in our study, 41 are presumed to inhabit the epioceanic domain, yet they still exhibit a significant positive relationship (r = 0.617) between fractal dimension and whorl height. This means that this correlation is not restricted to neritic ammonites and may be a function of shell size as proxied by whorl height. There is some inconsistency between these two studies including the vastly different heteromorphic shell forms of Ancyloceratina (with many non-planispiral forms) and temporal variation. Nevertheless, our results provide insight on the role of corrugated septal margins

  18. Results of a prospective randomised study comparing a non-invasive surgical zipper versus intracutaneous sutures for wound closure

    NARCIS (Netherlands)

    Roolker, W.; Kraaneveld, E.; Been, H. D.; Marti, R. K.

    2002-01-01

    A prospective randomised study was undertaken to investigate the advantages and disadvantages of a non-invasive surgical zipper (Medizip) vs intracutaneous sutures skin closure in orthopaedic surgery. The study group consisted of 120 consecutive patients, 45 men and 75 women with a mean age of 47

  19. A Prospective, Randomized, Single-Blind Study Comparing Cyanoacrylate Adhesives to Sutures for Wound Closure in Skin Cancer Patients.

    Science.gov (United States)

    Bartenstein, Diana W; Cummins, Deborah L; Rogers, Gary S

    2017-11-01

    Cyanoacrylate tissue adhesives are not more likely to result in wound dehiscence or infection than sutured closures. However, suturing is the gold standard for optimal cosmetic appearance of scars. To determine whether cyanoacrylate tissue adhesives produce a cosmetic outcome equivalent to sutures at 3 months. Secondary outcomes include time for wound closure, time spent on wound care, and surgeon and patient satisfaction. Seventy-one patients scheduled for skin cancer excision at Beverly Hospital were included in this prospective, randomized, single-blind study. Cosmetic appearance was assessed by a masked panel of dermatologists and plastic surgeons who evaluated digital photographs. Secondary outcomes were assessed by nursing recordings and patient and surgeon evaluations. There was no significant difference in wound appearance (Visual Analog Scale: p = .4693, modified Hollander Wound Evaluation Score: p = .6413) between adhesives and sutures. It was faster and easier for a surgeon to use adhesives, and subjects spent less time caring for and were more satisfied by wounds sealed with adhesives than sutures. Cyanoacrylate tissue adhesives produce cosmetic outcomes that are not statistically significantly different than sutures; furthermore, they are associated with fast application, easy wound care, and patient satisfaction.

  20. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  1. In vivo evaluation of a novel mesh suture design for abdominal wall closure.

    Science.gov (United States)

    Souza, Jason M; Dumanian, Zari P; Gurjala, Anandev N; Dumanian, Gregory A

    2015-02-01

    The authors present a novel mesh suture design aimed at minimizing the early laparotomy dehiscence that drives ventral hernia formation. The authors hypothesized that modulation of the suture-tissue interface through use of a macroporous structure and increased aspect ratio (width-to-height ratio) would decrease the suture pull-through that leads to laparotomy dehiscence. Incisional hernias were produced in 30 rats according to an established hernia model. The rat hernias were randomized to repair with either two 5-0 polypropylene sutures or two midweight polypropylene mesh sutures. Standardized photographs were taken before repair and 1 month after repair. Edge-detection software was used to define the border of the hernia defect and calculate the defect area. Histologic analysis was performed on all mesh suture specimens. Seventeen hernias were repaired with mesh sutures and 13 were repaired with conventional sutures. The mean area of the recurrent defects following repair with mesh suture was 177.8 ± 27.1 mm2, compared with 267.3 ± 34.1 mm2 following conventional suture repair. This correlated to a 57.4 percent reduction in defect area after mesh suture repair, compared with a 10.1 percent increase in defect area following conventional suture repair (p sutures pulled through the surrounding tissue, whereas 65 percent (17 of 26) of the conventional sutures demonstrated complete pull-through. Excellent fibrocollagenous ingrowth was observed in 13 of 17 mesh suture specimens. Mesh sutures better resisted suture pull-through than conventional polypropylene sutures. The design elements of mesh sutures may prevent early laparotomy dehiscence by more evenly distributing distracting forces at the suture-tissue interface and permitting tissue incorporation of the suture itself.

  2. A COMPARATIVE STUDY OF SKIN STAPLERS WITH SKIN SUTURES IN ABDOMINAL SKIN WOUND CLOSURE IN GASTROINTESTINAL MALIGNANCY – AN INSTITUTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Nafeesa

    2016-03-01

    Full Text Available OBJECTIVES The objectives of this study were to compare the two techniques, skin staplers and conventional sutures in abdominal skin wound closure with respect to the total cost, operative time required, incidence of wound infection, postoperative pain and cosmetic outcome. MATERIALS AND METHODS The study was conducted on 100 patients undergoing elective surgery for GI malignancies from December 2013 to May 2015 in the Department of General Surgery, Government Medical College, Kozhikode. The patients were randomly assigned to closure by suture or staple. RESULT The study groups included 50 patients who underwent wound closure by staplers and 50 patients who underwent closure by non-absorbable ethilon sutures. The time taken for wound closure was found to be statistically significant, with staplers requiring five times less duration than conventional sutures. The average cost of using stapler was found to be significantly more expensive than suture. There was no significant difference in post-operative pain between the two groups. The incidence of wound infection was more in stapler group than in suture group although statistically non-significant. The cosmetic outcome with stapler closure was found to be significantly superior to that with sutures.

  3. Surgical site infections after abdominal closure in colorectal surgery using triclosan-coated absorbable suture (PDS Plus) vs. uncoated sutures (PDS II): a randomized multicenter study.

    Science.gov (United States)

    Baracs, Jozsef; Huszár, Orsolya; Sajjadi, Shahram Ghotb; Horváth, O Peter

    2011-12-01

    Surgical site infections (SSI) are the third most common hospital-acquired infections and account for 14% to 16% of all such infections. In elective colorectal operations, the international SSI rate ranges from 4.7%-25%. In a previous retrospective study in this department, the SSI rate was unacceptably high (25%), and the promising different international evaluations of triclosan-coated suture materials encouraged us to create a multicenter randomized trial to improve our results. The main goal of this study was to compare triclosan-coated and uncoated absorbable suture (PDS Plus(®) with PDS II(®)) in elective colorectal operations. This was an internet-based study involving seven surgical centers. All the elective colorectal operations were performed by experienced surgeons. For abdominal fascia closure, running looped PDS was applied; triclosan-coated or uncoated PDS was chosen by computer randomization. Pre-operative and peri-operative variables such as gender, body mass index, neoadjuvant therapy, type II diabetes mellitus, amount of wound dressing material used, nursing days, and microbiological results were recorded. After the operation, the patient's data and risk factors were collected in a password-protected online database. From 485 patients randomized, SSI was documented in 47 patients (12.5%), 23 (12.2%) in the group having triclosan-coated sutures (n=188) and 24 (12.2%) in the uncoated suture group (n=197), a non-significant difference. Of all SSIs, 13 (27.7%) were diagnosed only after discharge, being recognized in the outpatient setting, with four patients in the triclosan suture group (8.5%) and nine in the uncoated suture group (19.2%) being affected with no significant differences in the demographic data. Microbiological examinations, in addition to the same colon flora in both groups, revealed two gram-positive infections in the uncoated suture group. The hospital stay and costs of dressings were significantly higher in patients having SSIs

  4. Intraoperative handling and wound healing of arthroscopic portal wounds: a clinical study comparing nylon suture with wound closure strips.

    Science.gov (United States)

    Bhattacharyya, Mayukh; Bradley, Helen

    2008-05-01

    This prospective, single-centre study compared wound closure methods in patients undergoing arthroscopy. Closure of arthroscopic portal wounds with sterile adhesive strips is effective and convenient for wound management. The method was associated with a reduced potential for infection, faster renewal of tensile strength, greater cost effectiveness, and better cosmetic effects comparing with suture closure. This method of wound closure may also reduce the incidence of needle stick injury in the theatre environment. Thereby the incidence of percutaneous exposure following a surgical procedure may not facilitate transmission of blood borne pathogens such as human immunodeficiency virus (HIV), hepatitis C virus and hepatitis B virus. As a result it may reduce litigation in today's changing healthcare climate.

  5. Interrupted or continuous slowly absorbable sutures – Design of a multi-centre randomised trial to evaluate abdominal closure techniques INSECT-Trial [ISRCTN24023541

    Directory of Open Access Journals (Sweden)

    Büchler Markus W

    2005-03-01

    Full Text Available Abstract Background The closure of the abdomen after median laparotomy is still a matter of debate among surgeons. Further well designed and performed randomised controlled trials determining the optimal method of abdominal fascial closure are needed. Design This is a three armed, multi-centre, intra-operatively randomised, controlled, patient blinded trial. Over 20 surgical departments will enrol 600 patients who are planned for an elective primary abdominal operation. The objective of this study is to compare the frequency of abdominal incisional hernias between two continuous suture techniques with different, slowly absorbable monofilament materials and an interrupted suture using an absorbable braided suture material at one year postoperatively. Conclusion This trial will answer the question whether the continuous abdominal wall closure with a slowly absorbable material with longitudinal elasticity is superior to the continuous suture with a material lacking elasticity and to interrupted sutures with braided thread.

  6. A randomised controlled trial of absorbable versus non-absorbable sutures for skin closure after open carpal tunnel release.

    LENUS (Irish Health Repository)

    Theopold, C

    2012-05-01

    We compared the aesthetic outcome of scars after closure of open carpal tunnel incisions with either absorbable 4-0 Vicryl Rapide or non-absorbable 4-0 Novafil. Patients were recruited in a randomized controlled trial and scars were scored at 6 weeks using a modified Patient and Observer Scar Assessment Scale. Scores demonstrated differences only for pain, vascularity and cross-hatching between both groups, though none of these were statistically significant. The dissolving and falling out of Vicryl Rapide was significantly more comfortable than removal of 4-0 Novafil sutures, assessed on a numerical analogue scale. There was no difference in infection rate between both study groups, supporting overall the use of Vicryl Rapide for the closure of palmar hand incisions, in light of the convenience and cost savings associated with absorbable sutures.

  7. Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection: A comparative clinical study

    National Research Council Canada - National Science Library

    Nagaraj, Vaibhav; Rajkumar, GC; Ghosh, Abhishek; Nanjappa, Madan

    2015-01-01

    ..., economy and aesthetics of the resultant scar. Aim: (1) To compare surgical stainless steel staples and silk sutures for primary wound closure, with respect to presence/absence of wound infection and dehiscence (2...

  8. Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection: A comparative clinical study

    National Research Council Canada - National Science Library

    Ghosh, Abhishek; Nanjappa, Madan; Nagaraj, Vaibhav; Rajkumar, G C

    2015-01-01

    ..., economy and aesthetics of the resultant scar. (1) To compare surgical stainless steel staples and silk sutures for primary wound closure, with respect to presence/absence of wound infection and dehiscence (2...

  9. Guitar-String Suture to Facilitate Closure of a Finger-like Flap for Reconstruction of the Nose.

    Science.gov (United States)

    Querol-Cisneros, E; Redondo, P

    2017-09-01

    The basic principle of a lobed or finger-like transposition flap is that, after covering the defect with the transposed tissue, the donor site is closed primarily. With large defects, a second lobe may be added to the flap if primary closure of the area left by the first lobe is not possible. The flap can often be made to adapt to the defect, but this maneuver, in combination with primary closure of the adjacent tissue, can sometimes produce excessive tension and compromise the blood supply. We present a series of 4 patients with epithelial tumors of the lateral wall of the nose. The defects left by surgical excision were covered by finger-like transposition flaps. Subcutaneous sutures called guitar-string sutures were used to reduce the size of the defect and facilitate tension-free closure. We propose use of the guitar-string subcutaneous suture in those cases in which the defect is larger than the area that can be covered by the flap. This will make it easier to adapt the flap to the defect and will reduce the risk of excessive tension causing necrosis of the transposed tissue. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  10. Use of suture-mediated vascular closure devices for the management of femoral vein access after transcatheter procedures.

    Science.gov (United States)

    Shaw, James A; Dewire, Elizabeth; Nugent, Alan; Eisenhauer, Andrew C

    2004-12-01

    Groin complications remain the most common complication of cardiac catheterization procedures. While the use of closure devices is increasing for arterial sheaths, venous sheaths tend to be removed and hemostasis achieved with manual compression. We report our experience using Perclose suture-mediated vascular closure device to achieve hemostasis and early mobility in patients who have had venous access as part of their procedure. There were a total of 42 patients (21 males; average age, 63.5 years) studied. The majority of the patients had 7 Fr sheaths (24), with access sites of sheaths up to 14 Fr being closed with this technique. Two patients developed complications at the access site: one patient requiring rehospitalization for intravenous antibiotics because of late access site infection, and one patient with deep venous thrombosis and pulmonary emboli. We conclude that the use of the Perclose suture-mediated closure device for closure of femoral venous access sites is feasible and should be considered especially in patients with larger venous sheaths and those at increased risk of groin complications. (c) 2004 Wiley-Liss, Inc.

  11. A comparison of 2-octyl cyanoacrylate adhesives versus conventional suture materials for eyelid wound closure in rabbits.

    Science.gov (United States)

    Ahn, Hee-Bae; Shin, Dong-Min; Roh, Mee-Sook; Jeung, Woo-Jin; Park, Woo-Chan; Rho, Sae-Heun

    2011-04-01

    To evaluate the clinical efficacy and histopathological tolerance of 2-octyl cyanoacrylate versus conventional suture materials for eyelid wound closure in rabbits. We performed an experimental study on 16 eyes of eight New Zealand albino rabbits. Eyelid incisions of 15 mm were done 4mm from the upper eyelid margin in both eyes. The eyes of the rabbits were divided into two groups: eyelid incisions of the right eye were closed by a 2-octyl cyanoacrylate adhesive (group A) and eyelid incisions of the left eye were closed by 7-0 nylon sutures (group B). At 1, 2, 4, and 8 weeks after surgery, the rabbits were macroscopically examined and then sacrificed. The specimens of their eyelid tissues were stained by a hematoxylin and eosin stain and Masson-trichrome stain, and were observed under microscope. Both eyelid surgical closure methods were found to be equally efficacious in fixing the eyelids of groups A and B, and their clinical efficacy was similar. Histopathological findings of the hematoxylin and eosin stain of group A showed less inflammatory infiltration than group B at 2 weeks. There were no significant histopathological differences between the two groups at 1, 4, and 8 weeks. The degree of fibrosis of the Masson-trichrome stain was similar between the two groups at 8 weeks. The 2-octyl cyanoacrylate adhesive proved to be an effective eyelid closure method and was very well tolerated by the skin surface. 2-Octyl cyanoacrylate could be used as an alternative tissue adhesive for eyelid wound closure along with conventional suture materials. © 2011 The Korean Ophthalmological Society

  12. Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade

    Energy Technology Data Exchange (ETDEWEB)

    Zorger, Niels; Finkenzeller, Thomas; Lenhart, Markus; Hamer, Okka; Paetzel, Christian; Borisch, Inghita; Toepel, Ingolf; Feuerbach, Stefan; Link, Johann [University of Regensburg Klinikum, Franz-Josef-Strauss-Allee 11, 93042, Regensburg (Germany)

    2004-04-01

    The aim of this study was evaluation of a closure device (Perclose, Menlo Park, Calif.) for closure of the femoral artery access site in patients undergoing aggressive anticoagulation and platelet blockade after carotid stenting. Fifty-five patients who received clopidogrel in addition to aspirin and heparin as medication for carotid stenting were included for suture of the femoral access site after using 7- or 8-F guide catheters. The technical success, the time for suture, the clotting parameters, and complications were examined. Follow-up investigations, including ultrasound and clinical examinations, were performed. The groin was checked for possible hematoma, pseudoaneurysm, arteriovenous fistula, and local infection. Technical success was obtained in 51 of 54 patients (94%) after a mean procedure time of 6 min (range 5-10 min). The suture device was not used in one patient (2%) for anatomical reasons and failed to obtain hemostasis in 3 of 54 (6%) patients. In 4 of 54 patients (7%) bleeding was observed at the punctured site 4-6 h after intervention which was treated by a compression bandage. The mean dedicated activated clotting time was 137 s (range 29-287 s) before intervention and 349 s (150-958 s) just before deploying the Perclose device. During follow-up after 2 days (range 2-6 days) and 6 months no further complications of the puncture site were observed except for two large groin hematomas. No major complications occurred. Closure of the femoral access site after carotid stenting using a Perclose closure device is safe and effective even in patients receiving an aggressive anticoagulation and antiplatelet therapy. (orig.)

  13. Osteoprotegerin deficiency results in disruption of posterofrontal suture closure in mice: implications in nonsyndromic craniosynostosis.

    Science.gov (United States)

    Beederman, Maureen; Kim, Stephanie H; Rogers, M Rose; Lyon, Sarah M; He, Tong-Chuan; Reid, Russell R

    2015-06-01

    Little is known about the role of osteoclasts in cranial suture fusion. Osteoclasts are predominantly regulated by receptor activator of nuclear factor kappa B and receptor activator of nuclear factor kappa B ligand, both of which lead to osteoclast differentiation, activation, and survival; and osteoprotegerin, a soluble inhibitor of receptor activator of nuclear factor kappa B. The authors' work examines the role of osteoprotegerin in this process using knockout technology. Wild-type, osteoprotegerin-heterozygous, and osteoprotegerin-knockout mice were imaged by serial micro-computed tomography at 3, 5, 7, 9, and 16 weeks. Suture density measurements and craniometric analysis were performed at these same time points. Posterofrontal sutures were harvested from mice after the week-16 time point and analyzed by means of histochemistry. Micro-computed tomographic analysis of the posterofrontal suture revealed reduced suture fusion in osteoprotegerin-knockout mice compared with wild-type and heterozygous littermates. Osteoprotegerin deficiency resulted in a statistically significant decrease in suture bone density in knockout mice. There was no reduction in the density of non-suture-containing calvarial bone between wild-type and osteoprotegerin-knockout mice. Histochemistry of suture sections supported these micro-computed tomographic findings. Finally, osteoprotegerin-knockout mice had reduced anteroposterior skull distance at all time points and an increased interorbital distance at the week-16 time point. The authors' data suggest that perturbations in the expression of osteoprotegerin and subsequent changes in osteoclastogenesis lead to alterations in murine cranial and posterofrontal suture morphology.

  14. Vaginal cuff closure: a comparison between the vaginal route and laparoscopic suture in patients undergoing total laparoscopic hysterectomy.

    Science.gov (United States)

    Hwang, Jong Ha; Lee, Jae Kwan; Lee, Nak Woo; Lee, Kyu Wan

    2011-01-01

    To compare the vaginal route and laparoscopic suture for vaginal cuff closure (VCC) in patients undergoing a total laparoscopic hysterectomy (TLH). A total of 471 women who required hysterectomy were allocated to two groups. 261 women had TLH via VCC by the vaginal route and 210 women had TLH via VCC by laparoscopic suture. All TLHs were performed by the same laparoscopic surgeon. The cuff-related complications included vaginal disruption (3.4%), dehiscence (1.27%), vaginal vault bleeding (1.91%), vaginal spotting (19.32%), granulation (1.27%), cuff infection (1.49%), and yellowish vaginal discharge (6.16%). No difference in vaginal cuff complications was found between the laparoscopic and vaginal approach. The median operation time was significantly shorter for the laparoscopic suture (76.74 min, range 40-220; 95% CI 74.84-83.45) than the vaginal route for VCC (85.77 min, range 45-290; 95% CI 86.87-95.36) after hysterectomy (p < 0.001). For VCC with TLH, laparoscopic suture was a safe and less time-consuming procedure. The cuff-related complications were similar in the two groups. Copyright © 2010 S. Karger AG, Basel.

  15. Use of antibacterial sutures for skin closure in controlling surgical site infections: a systematic review of published randomized, controlled trials.

    Science.gov (United States)

    Sajid, Muhammad S; Craciunas, L; Sains, P; Singh, K K; Baig, M K

    2013-07-01

    The objective of this article is to systematically analyse the randomized, controlled trials that compare the use of antibacterial sutures (ABS) for skin closure in controlling surgical site infections. Randomized, controlled trials on surgical patients comparing the use of ABS for skin closure in controlling the surgical site infections were analysed systematically using RevMan® and combined outcomes were expressed as odds ratios (OR) and standardized mean differences (SMD). Seven randomized, controlled trials evaluating 1631 patients were retrieved from electronic databases. There were 760 patients in the ABS group and 871 patients in the simple suture group. There was moderate heterogeneity among trials (Tau(2) = 0.12; chi(2) = 8.40, df = 6 [P surgical patients was associated with a reduced risk of developing surgical site infections (OR, 0.16; 95% CI, 0.37, 0.99; z = 2.02; P surgical procedures. Use of ABS for skin closure in surgical patients is effective in reducing the risk of surgical site infection and postoperative complications. ABS is comparable with SS in terms of length of hospital stay and duration of operation.

  16. Randomized comparison of polyglycolic acid and polyglyconate sutures for abdominal fascial closure after laparotomy in patients with suspected impaired wound healing

    DEFF Research Database (Denmark)

    Osther, P J; Gjøde, P; Mortensen, Sophie Berit Bondegaard

    1995-01-01

    A randomized study of abdominal fascial closure using interrupted polyglyconate and polyglycolic acid sutures after laparotomy was carried out in 204 consecutive patients with suspected impaired wound healing. There were no statistically significant differences between the two sutures with regard...... to the development of fascial disruption and incisional hernia. Wound infection demanding surgical intervention was found in 7 per cent of patients with polyglyconate sutures and in 16 per cent of those with polyglycolic acid sutures (P = 0.04). Monofilament polyglyconate suture does not reduce the incidence...... of fascial disruption and incisional hernia after laparotomy in patients with suspected impaired wound healing but the incidence of wound infection may be reduced compared with that of multifilament polyglycolic acid suture....

  17. Association between Triclosan-Coated Sutures for Abdominal Wall Closure and Incisional Surgical Site Infection after Open Surgery in Patients Presenting with Fecal Peritonitis: A Randomized Clinical Trial.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Alonso, Natalia; Morales, Vicente; Llavero, Carolina

    2015-10-01

    A factor that may influence the incidence of surgical site infections (SSIs) is the suture used for closure of the abdominal wall because bacteria may adhere to the suture material. Sutures can be coated with antibacterial substances that may reduce the bacterial load in the incision. The aim of this study was to evaluate the effect of triclosan-coated sutures used in abdominal wall closure in patients with fecal peritonitis. A randomized study was performed. Inclusion criteria were intra-operative diagnosis of fecal peritonitis secondary to acute diverticulitis perforation, neoplastic tumor perforation, or colorectal anastomotic leak of previous elective colorectal resection. The patients were randomly assigned to either abdominal wall closure with triclosan-coated sutures (group 1) or sutures without triclosan (group 2). Fifty patients were included in group 1 and 51 in group 2. The incisional SSI rate was 10% in group 1 and 35.3% in group 2 (p=0.004; odds ratio [OR]=0.204; 95% confidence interval [CI] 0.069-0.605). A significant reduction in SSIs caused by Escherichia coli and Enterococcus faecalis was observed in group 2. The use of triclosan-coated sutures in fecal peritonitis surgery reduces the incidence of incisional SSI.

  18. Efficacy of Murva (Sansevieria roxburghiana Schult. and Schult.f.) as a suture material in closure of incisions in third molar surgeries: A prospective study.

    Science.gov (United States)

    Lambade, Pravin; Thorat, Ashutosh

    2017-01-01

    Adequate closure of the surgical wound is one of the most important aspects of surgery; improper suturing techniques or improper suturing materials sometimes compromise the success of surgery. Many synthetic materials have replaced the natural materials, which were once used for suturing in the ancient era, and Murva is one of them. There are references of Murva (Sansevieria roxburghiana Schult. and Schult.f.) at various contexts of "Sushruta Samhita" where it has been used as a suture material. It is a xerophytic herbaceous plant occurring abundantly in the eastern coastal region of India. The aim of this study is to evaluate the efficacy of Murva fibers as a suturing material in closure of intraoral incision in third molar surgeries. Fifty incisions (Wards incision) placed for the surgical removal of mandibular third molar were sutured with Murva, and follow-up was carried out postoperatively on 1st, 2nd, 3rd, and 7th day. Patients were evaluated for pain, swelling, bleeding, infection, wound dehiscence, local tissue irritation, and bacterial colonization. On various follow-ups, progressively significant and predictable healing was observed without any uneventful evidence. The use of Murva as a suture material proved to be effective in closure of intraoral incisions.

  19. Comparison of Knotless Barbed Suture Versus Monofilament Suture in the Oral Cavity of Cats.

    Science.gov (United States)

    Durand, Corinne L

    2017-09-01

    The present study compares a knotless, barbed, absorbable suture material against a conventional monofilament absorbable suture material in oral mucosal wound closure. The parameters measured include time of closure and differences in healing at 2 and 4 weeks postoperatively. A prospective study comparing a knotless, barbed suture system with conventional absorbable sutures was undertaken in 19 cats. Nineteen cats had full mouth extractions performed. Following the extraction procedures, the incisions in the arcades (maxillary and mandibular) were apposed with the barbed, knotless suture system in a continuous pattern on one side and with a conventional smooth suture in an interrupted pattern on the other. Suturing times for each arcade were recorded. The material used to close the first side of each cat varied. Healing, dehiscence, and other complications were assessed at 2 and 4 weeks postoperatively. The average closure time (± standard deviation) per quadrant with conventional monofilament suture was 8.7 (±1.3) minutes, while barbed suture required an average of 5.1 (±1.1) minutes per quadrant to complete the suture. This difference (95% confidence interval) of 3.6 (±3.2-4.1) minutes per quadrant was statistically significant ( P < .001). Dehiscence and ranula-like swelling formation were noted as uncommon postoperative complications, but the differences were not significant between the groups. Barbed, knotless sutures resulted in faster closure times than conventional, simple interrupted, monofilament sutures with similar healing and complication rates. To the author's knowledge, there is no current literature comparing conventional absorbable monofilament sutures to a knotless, barbed, absorbable suture system for closure of oral mucosal incisions in cats.

  20. The Effect of Antibiotic-Coated Sutures on the Incidence of Surgical Site Infections in Abdominal Closures: a Meta-Analysis.

    Science.gov (United States)

    Elsolh, Basheer; Zhang, Lisa; Patel, Sunil V

    2017-05-01

    This meta-analysis aims to determine if antibiotic-impregnated sutures for abdominal fascial closure prevent postoperative surgical site infections (SSIs), hernias, and/or dehiscence. MEDLINE and EMBASE databases (1946-2016) were searched. Randomized controlled trials comparing antibiotic-impregnated sutures to standard sutures for abdominal closure were eligible. Risk of bias was evaluated using the Cochrane Handbooks definitions. Four-hundred fifty articles were reviewed; five eligible studies (N = 3117) were identified. All studies routinely used prophylactic antibiotics. Overall risk of SSI in the antibiotic-impregnated suture group was 10.4 vs. 13.0% in the control group. Pooled data showed no difference in SSI between suture types (odds ratio 0.79, 95% CI 0.57-1.09, P = 0.15, I 2 = 44%). There was no evidence of subgroup effect by suture material (polydioxanone vs. polyglactin 910; P = 0.19) or by comparing colorectal surgery studies to others (P = 0.67). There was a high risk of bias in two studies, one for high loss to follow-up and one for not using an intent-to-treat analysis. Our meta-analysis is the most comprehensive review on the utility of antibiotic-impregnated sutures in abdominal surgery to prevent SSI. We found no evidence to support routine use of these sutures.

  1. Safety and Efficacy of Single-site Phacotrabeculectomy With Mitomicin C Using Nylon and Polyglactin Suture for Scleral Tunnel Closure.

    Science.gov (United States)

    Vijaya, Lingam; David, Rathini L

    2015-01-01

    To evaluate the efficacy of polyglactin use along with nylon suture in scleral tunnel closure after single-site phacotrabeculectomy. This retrospective case series included 139 eyes of 139 patients who had scleral tunnel closure with 1 polyglactin and 1 nylon suture after single-site phacotrabeculectomy with a low dose of mitomycin C between 2002 and 2005. The intraocular pressure (IOP), the visual acuity, the number of glaucoma medications, postoperative complications, and interventions were the outcomes measured. The majority of them had primary open-angle glaucoma (93 eyes, 67%), 93 eyes (67%) had severe glaucomatous optic neuropathy, and 77 eyes (55.3%) had severe visual-field loss. The IOP decreased from a mean preoperative value of 18.1±5.3 mm Hg on a mean number of 1.8±0.8 glaucoma medications to mean IOPs of 13.3±4.6, 14.0±4.3, and 11.8±3.9 mm Hg on a mean number of 0.2±0.6, 0.3±0.7, 0.5±1.0 glaucoma medications (PNylon suturelysis with laser was performed in 16 eyes (11.5%). The technique used here seems to be effective in controlling the IOP and has very minimal associated complications.

  2. Wound closure and wound healing. Suture techniques in contemporary periodontal and implant surgery: Interactions, requirements, and practical considerations.

    Science.gov (United States)

    Zuhr, Otto; Akakpo, Dodji Lukas; Hürzeler, Markus

    2017-07-20

    In contemporary reconstructive periodontal and implant surgery, attaining uncomplicated wound healing in the early postoperative healing phase is the key to achieving a successful treatment outcome and is of central interest, from the clinical as well as the scientific perspective. The realization of primary wound healing is the central challenge in most cases. Two of the evidence-based factors that affect postoperative wound healing can be influenced by the surgeon: the blood supply to the surgical site and postoperative wound stability. The surgical suture is a key determinant of whether adequate wound stability is achieved in this context without complicating the course of wound healing by exerting unnecessary trauma or excessive tensile strain on the wound edges. Therefore, the inclusion of anchors in the suturing process that make it possible to achieve the best wound stability possible is often an important key to success. This article provides an overview of the principles of successful wound closure that are relevant to postoperative wound healing in order to equip dentists with the tools needed for the correct, indication-specific selection and performance of surgical suturing techniques in daily practice.

  3. A prospective study on the effect of modified alar cinch sutures and V-Y closure versus simple closing sutures on nasolabial changes after Le Fort I intrusion and advancement osteotomies.

    NARCIS (Netherlands)

    Muradin, M.S.; Seubring, K.; Stoelinga, P.J.W.; Bilt, A. van der; Koole, R.; Rosenberg, A.J.

    2011-01-01

    PURPOSE: The purpose of this study was to determine whether a modified alar cinch suture and V-Y closure (mACVY) have a beneficial effect on labial form after Le Fort I intrusion and advancement osteotomies and whether they result in excessive upward nasal tip rotation. Both are possible effects

  4. Effect of the Abdominal Fascial Closure with Triclosan-Coated Sutures in Fecal Peritonitis, on Surgical Site Infection, and Evisceration: A Retrospective Multi-Center Study.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Alonso, Natalia; Ochagavía, Aina; Arroyo, Antonio; Llavero, Carolina

    2018-01-01

    Surgical site infection (SSI) is a frequent complication in dirty surgery, reaching rates of up to 40%. The incidence of SSI might be influenced by the suture used for closure of the abdominal fascia. Sutures coated with antibacterial substances may reduce the bacterial load in the incision. A retrospective study of patients with intra-operative diagnosis of fecal peritonitis undergoing a laparotomy in three Spanish hospitals was performed. Fascial closure consisted in running loop suture of Polyglactin (Vicryl loop®, Johnson & Johnson, New Brunswick, NY; group 1), running loop suture of triclosan-coated polyglactin (Vicryl plus loop®; group 2), running loop suture of polydioxanone (PDS loop® Johnson & Johnson; group 3), and running loop suture of triclosan-coated polydioxanone (PDS plus loop®; group 4). Incisional SSI and evisceration rates were assessed. One hundred four patients were included. There were no differences in age, gender, comorbidities, etiology of peritonitis, and mortality among groups. Surgical site infection rate was 34.6% in group 1; 8% in group 2; 33% in group 3; and 10% in group 4 (p = 0.029). The use of triclosan-coated sutures is associated with lower risk of SSI (risk ratio [RR]: 9; p = 0.003). Evisceration rate was 0% in groups 1 and 2; 15.2% in group 3; and 10% in group 4 (p = 0.05). All patients suffering from evisceration presented previous SSI. The use of monofilament sutures is associated with higher risk of evisceration (RR: 6.35; p = 0.033). Triclosan-coated sutures reduce SSI rate in fecal peritonitis, without differences between braided and monofilament type. The use of monofilament sutures is related to higher risk of evisceration, independent of a triclosan coating.

  5. Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection: A comparative clinical study

    Directory of Open Access Journals (Sweden)

    Abhishek Ghosh

    2015-01-01

    Full Text Available Introduction: Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection, in context of rapid application, approximation of the skin edges, economy and aesthetics of the resultant scar. Aim: (1 To compare surgical stainless steel staples and silk sutures for primary wound closure, with respect to presence/absence of wound infection and dehiscence (2 To compare the resultant scar following the two different methods of the closure at 3 rd month postoperatively with the help of visual analog scale and analyze the result statistically Design: This study was designed to compare skin closure using staples and silk sutures in patients undergoing neck dissection, using both methods in one-half of the same wound; thus each wound affording its own control. Materials and Methods: The study was conducted on patients requiring collar line incision (high submandibular incision with or without a cephalad extension of midline lower lip split incision for surgical access, who presented to the Department of Oral and Maxillo-Facial Surgery. (1 Sample size: 10 (2 Study design: Prospective Comparative study (3 Study duration: One and half years (4 Surgical stainless steel staples: Proximate Plus MD 35 W, Ethicon Endo Surgery (5 Sutures: 3-0 Ethiprime NW 5003, Non-Absorbable Surgical Suture, Mersilk-90 cm, Ethicon, (16 mm 3/8 circle cutting needle. Conclusion: It wass concluded that there is no significant difference between the scars observed in the regions of incision which underwent primary closure by two different methods, that is surgical stainless steel staples and 3-0 Mersilk Sutures.

  6. Subtotal cranial vault remodelling in anterior sagittal suture closure: impact of age on surgical outcome

    NARCIS (Netherlands)

    Engel, M.; Hoffmann, J.; Muhling, J.; Castrillon-Oberndorfer, G.; Seeberger, R.; Freudlsperger, C.

    2012-01-01

    Isolated fusion of the sagittal suture is usually treated before 1 year of age, but some patients present at a later age. The aim of this study was to evaluate the impact of children's age on the surgical outcome. The authors investigated 46 patients with isolated nonsyndromic sagittal

  7. The effect of alar cinch sutures and V-Y closure on soft tissue dynamics after Le Fort I intrusion osteotomies.

    NARCIS (Netherlands)

    Muradin, M.S.; Rosenberg, A.; Bilt, A. van der; Stoelinga, P.J.W.; Koole, R.

    2009-01-01

    Adverse effects on the soft tissues after Le Fort I osteotomies include: broadening of the alar base, loss of vermilion show of the upper lip and down sloping of the commissures. In theory, an alar cinch suture combined with a muco-musculo-periosteal V-Y closure (ACVY) should improve not only the

  8. Laparoscopic Linear Stapled Running Enterotomy Closure in Roux-en-Y Gastric Bypass Using Absorbable Unidirectional Barbed Suture (Stratafix® 2/0).

    Science.gov (United States)

    Gys, Ben; Gys, Tobie; Ruyssers, Michael; Lafullarde, Thierry

    2017-10-01

    Laparoscopic running enterotomy closure for linear stapled Roux-en-Y gastric bypass (RYGB) may be enhanced by using unidirectional barbed sutures (Stratafix™ 2/0, Ethicon) as it eliminates the need for knot tying and assistance from a third hand. The objective of this paper is to present our technique using unidirectional barbed sutures (Stratafix™ 2/0, Ethicon). After stapling the gastrojejunostomy, we start the closure of the residual enterotomy unidirectional from left to right (single, full-thickness layer) which is cut without a knot. For the jejunojejunostomy, the residual enterotomy is closed perpendicular from top to bottom in order to avoid iatrogenic stricture formation (single, full-thickness layer). No backstitches are performed. We feel strongly that this technique might enhance running enterotomy closure for linear stapled RYGB.

  9. Comparison of Traditional Superficial Cutaneous Sutures Versus Adhesive Strips in Layered Dermatologic Closures on the Back-A Prospective, Randomized, Split-Scar Study.

    Science.gov (United States)

    Yang, Sherry; Ozog, David

    2015-11-01

    Bilayered suture repairs have become the standard of care in dermatologic surgery. However, the benefit of superficial sutures for fine epidermal alignment on high-tension areas remains unclear. To compare the overall cosmetic outcome of traditional epidermal sutures with adhesive strips in layered dermatologic repairs on the back. A total of 10 patients underwent standard elliptical excision on the back followed by subcutaneous closure with 4-0 polyglactin 910 buried sutures. Each half of the wound was then randomized to either 4-0 polypropylene running sutures or 1/4″ Steri-Strip films for epidermal approximation. Postoperative evaluations were completed in person at 2 weeks, 3 months, and 6 months using the Patient and Observer Scar Assessment Scale. The adhesive strip group had superior appearance and greater patient satisfaction at 2 weeks. Evaluation at 3 months and 6 months revealed no statistically significant difference in overall scar cosmesis. Adhesive strips result in equivalent long-term scar outcome when compared with traditional epidermal sutures and should be viewed as a time-saving alternative in layered dermatologic repairs on the back. This finding further corroborates that undermining and placement of deep buried sutures are the primary determinants of wound appearance.

  10. Outpatient angioplasty and stenting facilitated by percutaneous arterial suture closure devices

    Energy Technology Data Exchange (ETDEWEB)

    Wilde, N.T. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Bungay, P. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Johnson, L. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Asquith, J. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Butterfield, J.S. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom); Ashleigh, R.J. [South Manchester University Hospitals NHS Trust, Wythenshawe, Manchester (United Kingdom)]. E-mail: Ray.Ashleigh@smuht.nhs.uk

    2006-12-15

    Aim: To review our practice of outpatient percutaneous vascular interventions facilitated by an arterial suture device. Materials and methods: A retrospective review of all patients attending this tertiary centre for iliac or femoral intervention was undertaken between February 2001 and December 2004. All patients who underwent angioplasty or stenting had their puncture sites closed using a Perclose suture. Patients were kept flat for 15 min and allowed to fully mobilize at 60 min. Puncture sites were scored for visible bruising, haematoma and pain at discharge and on outpatient follow-up. Patient preference for future outpatient treatment was assessed. Results: Fifty-seven outpatients underwent 81 punctures. Forty-eight (84%) patients underwent iliac angioplasty; of those 42% underwent stent placement. Six patients (10%) required inpatient admission, five secondary to failed suture deployment. One patient had a non-closer-related puncture site intimal flap occlusion successfully repaired at surgery. Fifty-one (90%) patients discharged with a mean time of 157 min (60-280 min). Forty-six (92%) patients had no visible bruising or palpable haematoma on discharge. No patient had a haematoma greater than 2.5 cm. No discharged patient required readmission. Thirty percent reported a moderate to severe groin pain score (2-5/5) at discharge, increasing to 40% at follow-up. Forty-seven (98%) of the 48 patients, who expressed a preference, would be happy to undergo outpatient treatment again. Conclusion: Outpatient treatment is feasible, well tolerated and preferable to patients, but 10% will require inpatient admission. A planned post-procedure analgesia regimen or advice should be considered.

  11. Preliminary results from 28 cases of pilonidal cyst treated by excision and primary closure of the wound, reinforced with support suturing

    Directory of Open Access Journals (Sweden)

    Nelson de Souza Liboni

    2007-06-01

    Full Text Available Objectives: To describe the results of the surgical technique of pilonidalcyst excision with margins and primary closure of the operative woundwith support suturing. Methods: Twenty-eight patients with pilonidaldisease admitted to a private clinic between 1999 and 2006 underwentsurgical treatment by means of an elliptical longitudinal medial incisionproportional to the palpable tumor size and excision of cyst with 2-cmmargins above, below and laterally, and primary closure of the wound.To reduce the tension in the operative wound, suturing was performed,with a single support stitch of horizontal U-shape. The patients werefollowed up for periods ranging from 6 months to 3 years. Results:Two patients developed abscesses at the surgical site (7.1%, andone required complete opening of the operative wound for drainage.Both underwent excision and primary closure again. The pathologicalexamination demonstrated that these were not cases of relapse, butof recurrent abscess. No cases of non-infected collection (seroma andhematoma, spontaneous dehiscence of the operative wound or diseaserecurrence were recorded. Conclusions: The technique of pilonidal cystexcision with margins and primary closure of the wound reinforcedwith support suturing seems to be attractive, since it is characterizedby low complexity and low infection rate. Studies with larger samplesare needed to validate this surgical technique.

  12. Stretch force guides finger-like pattern of bone formation in suture

    Science.gov (United States)

    Kou, Xiao-Xing; Zhang, Ci; Zhang, Yi-Mei; Cui, Zhen; Wang, Xue-Dong; Liu, Yan; Liu, Da-Wei; Zhou, Yan-Heng

    2017-01-01

    Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling with the direction

  13. Stretch force guides finger-like pattern of bone formation in suture.

    Directory of Open Access Journals (Sweden)

    Bo-Hai Wu

    Full Text Available Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling

  14. Mesh Sutured Repairs of Abdominal Wall Defects

    National Research Council Canada - National Science Library

    Lanier, Steven T; Dumanian, Gregory A; Jordan, Sumanas W; Miller, Kyle R; Ali, Nada A; Stock, Stuart R

    2016-01-01

    BACKGROUND:A new closure technique is introduced, which uses strips of macroporous polypropylene mesh as a suture for closure of abdominal wall defects due to failures of standard sutures and difficulties with planar meshes...

  15. Surgical outcome after using a modified technique of the pi-procedure for posterior sagittal suture closure

    NARCIS (Netherlands)

    Engel, M.; Freudlsperger, C.; Hoffmann, J.; Muhling, J.; Castrillon-Oberndorfer, G.; Seeberger, R.

    2012-01-01

    Fusion of the sagittal suture is the most prevalent form of craniosynostosis. Due to the variety of deformities of scaphocephaly depending on the location of the fused sagittal suture, the surgical procedure has to be adjusted to the individual case. In this study, 38 patients with a predominantly

  16. Prospective comparison of collagen plug (angio-seal{sup TM}) and suture-mediated (the closer S{sup TM}) closure devices at femoral access sites

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yulri; Roh, Hong Gee; Choo, Sung Wook; Lee, Sung Hoon; Shin, Sung Wook; Do, Young Soo; Byun, Hong Sik; Park, Kwang Bo; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2005-12-15

    Rapid and effective hemostasis at femoral puncture sites minimizes both the hospital stay and patient discomfort. Therefore, a variety of arterial closure devices have been developed to facilitate the closure of femoral arteriotomy. The objective of this prospective study was to compare the efficacy of two different closure devices; a collagen plug device (Angio-Seal) and a suture-mediated closure device (the Closer S). From March 28, 2003 to August 31, 2004, we conducted a prospective study in which 1,676 cases of 1,180 patients were treated with two different types of closure device. Angio-Seal was used in 961 cases and the Closer S in 715 cases. The efficacy of the closure devices was assessed, as well as complications occurring at the puncture sites. Successful immediate hemostasis was achieved in 95.2% of the cases treated with Angio-Seal, and in 89.5% of the cases treated with the Closer S ({rho} < 0.05). The rates of minor and major complications occurring between the two groups were not significantly different. In the Closer S group, we observed four major complications (0.6%), that consisted of one massive retroperitoneal hemorrhage (surgically explored) and three pseudoaneurysms. In the Angio-Seal group, we observed three major complications (0.3%) that consisted of one femoral artery occlusion, one case of infection treated with intravenous antibiotics and one pseudoaneurysm. The use of Angio-Seal was found to be more effective than that of the Closer S with regard to the immediate hemostasis of the femoral puncture sites. However, we detected no significant differences in the rate at which complications occurred.

  17. The developing temporal bone: computed tomography measurements and assessment of suture closure from birth to 18 years of age.

    Science.gov (United States)

    Paetz, P; Goetz, G F; Lanfermann, H; Giesemann, A M

    2017-06-01

    To describe the normal CT appearance of the developing temporal bone in children from birth to 18 years of age. Two hundred and six temporal bone CTs of children from 0.14 to 18.95 years were retrospectively selected and reviewed. Temporal bones were measured in a standardized slice orientation using the length of the basal turn of the cochlea, the length and width of the petrous bone, the coronal extent, trailing edge and anterior-posterior dimension of the temporal bone and the angle between petrous bone's length and the midsagittal line in the axial plane showing the basal turn of the cochlea in its greatest extent. Two sutures, two synchondroses and three fissures of the temporal bone were evaluated and graded. Chosen measurements and calculations demonstrate an increase of values from 0 to 18 years with the greatest increase occurring during the first 2 years of life. The angle between the basal turn of the cochlea and the midsagittal line shows a large variability. Logarithmic trend lines illustrate larger measurements of males as compared to females. The ratio of the basal turn of the cochlea and the length of the petrous bone is about 1:4.1 (f/m) during the first year of life and about 1:6.1 (f)/1:6.8 (m) from 17 years onwards. Results of suture closure are described using box-and-whisker plots. The developing temporal bone grows the most during the first 2 years of life. Knowledge of changing proportions and suture closure is essential for evaluation of temporal bone CT of children.

  18. Load to Failure and Stiffness: Anchor Placement and Suture Pattern Effects on Load to Failure in Rotator Cuff Repairs.

    Science.gov (United States)

    Esquivel, Amanda O; Duncan, Douglas D; Dobrasevic, Nikola; Marsh, Stephanie M; Lemos, Stephen E

    2015-04-01

    Rotator cuff tendinopathy is a frequent cause of shoulder pain that can lead to decreased strength and range of motion. Failures after using the single-row technique of rotator cuff repair have led to the development of the double-row technique, which is said to allow for more anatomical restoration of the footprint. To compare 5 different types of suture patterns while maintaining equality in number of anchors. The hypothesis was that the Mason-Allen-crossed cruciform transosseous-equivalent technique is superior to other suture configurations while maintaining equality in suture limbs and anchors. Controlled laboratory study. A total of 25 fresh-frozen cadaveric shoulders were randomized into 5 suture configuration groups: single-row repair with simple stitch technique; single-row repair with modified Mason-Allen technique; double-row Mason-Allen technique; double-row cross-bridge technique; and double-row suture bridge technique. Load and displacement were recorded at 100 Hz until failure. Stiffness and bone mineral density were also measured. There was no significant difference in peak load at failure, stiffness, maximum displacement at failure, or mean bone mineral density among the 5 suture configuration groups (P sutures in the repair should be considered to judge the strength of the repair. Previous in vitro studies have shown the double-row rotator cuff repair to be superior to the single-row repair; however, clinical research does not necessarily support this. This study found no difference when comparing 5 different repair methods, supporting research that suggests the number of sutures and not the pattern can affect biomechanical properties.

  19. Closure of a direct inguinal hernia defect in laparoscopic repair with barbed suture: a simple method to prevent seroma formation?

    Science.gov (United States)

    Li, Junsheng; Zhang, Weiyu

    2018-02-01

    Seroma is a frequent postoperative complication after laparoscopic direct inguinal hernia repair (both in TAPP and TEP). There are several methods to address this problem; however, these techniques are not without problems. The purpose of this study was to introduce and evaluate a new technique to address this problem. This is a prospective study of consecutive patients. All patients diagnosed with direct inguinal hernias eligible for laparoscopic repair were included. A single surgeon performed all the included operations. During laparoscopic inguinal hernia repair (TAPP or TEP), we closed the direct hernia defect with barbed sutures around the transversalis fascia, inverted the apex of the attenuated transversalis fascia, and sutured it at the base to completely eradicate the defect cavity. Prosthetic mesh was not additionally fixed in all patients. The primary postoperative outcome parameter was seroma formation, and secondary outcome parameters included groin pain, surgical complications, and hernia recurrence. Twenty-five male patients with 36 sides of direct hernias were included in this study, and all procedures were carried out laparoscopically and successfully. Only one patient developed significant seroma, which resolved 1 month later. The early postoperative pain was minimal, and no recurrence and chronic pain occurred during the follow-up period (4-13 months). The present direct inguinal hernia defect closing technique with barbed suture is a simple, easily reproducible, and effective method for the prevention of seroma formation.

  20. The Role of Sex in Glottic Closure Pattern in People with Normal Voice

    Directory of Open Access Journals (Sweden)

    Yunes Jahani

    2011-06-01

    Full Text Available Background and Aim: Glottic closure pattern is one of the most important stroboscopic signs in judging the normality of laryngeal function. According to the recent researches, complete glottic closure is not the only pattern in normal phonation. The aim of this study was to investigate the glottic closure pattern in normal subjects and to understand the role of sex in having different glottic closure patterns.Methods: In a cross-sectional study, 80 subjects (58 females and 22 males; mean age of 21.19 years were randomly selected from a population of 218 students. After taking a full medical history and performing perceptual and voice self assessment, subjects without any vocal disorders were recruited. Videolaryngoscopic assessment was performed during producing the vowel sound /i/ in habitual, high, low, loud and soft levels of phonation. Glottic closure patterns were analyzed in different phonation and also were compared between males and females.Results: Although complete closure was the most frequent pattern, Y posterior chink was the second pattern in males (20.2% and females (39.4% in all phonation. The results revealed significant difference between males and females in glottic closure pattern (p=0.001. Moreover, significant differences were observed in habitual (p=0.004, high (p=0.006 and soft (p=0.02 phonations between males and females; however, the differences in low (p=0.7 and loud (p=0.19 phonations between males and females were not significant.Conclusion: Y posterior chink, as well as complete closure, are likely to be normal findings in people with normal voice. Besides, gender has a significant influence on glottic closure pattern.

  1. Ultrastructure, Histochemistry, and Mineralization Patterns in the Ecdysial Suture of the Blue Crab, Callinectes sapidus

    Science.gov (United States)

    Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark

    2005-12-01

    The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.

  2. Sutures - ridged

    Science.gov (United States)

    Ridged sutures ... The borders where these plates intersect are called sutures or suture lines. In an infant only a few minutes ... This makes the bony plates overlap at the sutures and creates a small ridge. This is normal ...

  3. Comparison of surgically induced astigmatism between horizontal and X-pattern sutures in the scleral tunnel incisions for manual small incision cataract surgery.

    Science.gov (United States)

    Eslami, Yadollah; Mirmohammadsadeghi, Arash

    2015-07-01

    Two types of popular scleral tunnel sutures in the manual small incision cataract surgery (MSICS) are horizontal and X-pattern sutures. Surgically induced corneal astigmatism (SIA) is a useful indicator of the suturing effect. To compare SIA between horizontal and X-pattern sutures in the scleral tunnel incisions for MSICS. Prospective, nonrandomized comparative trial. After superior scleral tunnel incision and capsulorhexis, the nucleus was prolapsed into the anterior chamber and delivered. The wound was sutured with either horizontal or X-pattern suture. The simulated keratometry values were derived from the corneal topography preoperatively and 1.5 and 3 months postoperatively. The SIA was calculated by Cartesian coordinates based analysis. Sixty-four patients (32 patients in each group) were included in the study. In the horizontal suture group, the SIA centroid values at 1.5 and 3 months after the surgery were 0.87 × 1° and 1.11 × 180°, respectively, showing induction of against-the-rule astigmatism. In the X-pattern suture group, the SIA centroid values at 1.5 and 3 months after the surgery were 0.61 × 97° and 0.66 × 92°, respectively, showing induction of mild with-the-rule astigmatism. The difference between the amount of SIA at 1.5 and 3 months after surgery was small. In the MSICS, the X-pattern sutures were preferred to the horizontal sutures in the patients without significant preoperative steepening in line with the central meridian of the incision. In the cases with significant preoperative steepening, sutureless surgery or horizontal sutures were preferred. Corneal astigmatism in the patients undergoing MSICS was stable at 1.5 months after the surgery.

  4. Comparison of surgically induced astigmatism between horizontal and X-pattern sutures in the scleral tunnel incisions for manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Yadollah Eslami

    2015-01-01

    Full Text Available Background: Two types of popular scleral tunnel sutures in the manual small incision cataract surgery (MSICS are horizontal and X-pattern sutures. Surgically induced corneal astigmatism (SIA is a useful indicator of the suturing effect. Aims: To compare SIA between horizontal and X-pattern sutures in the scleral tunnel incisions for MSICS. Design: Prospective, nonrandomized comparative trial. Materials and Methods: After superior scleral tunnel incision and capsulorhexis, the nucleus was prolapsed into the anterior chamber and delivered. The wound was sutured with either horizontal or X-pattern suture. The simulated keratometry values were derived from the corneal topography preoperatively and 1.5 and 3 months postoperatively. Statistical Analysis: The SIA was calculated by Cartesian coordinates based analysis. Results: Sixty-four patients (32 patients in each group were included in the study. In the horizontal suture group, the SIA centroid values at 1.5 and 3 months after the surgery were 0.87 × 1° and 1.11 × 180°, respectively, showing induction of against-the-rule astigmatism. In the X-pattern suture group, the SIA centroid values at 1.5 and 3 months after the surgery were 0.61 × 97° and 0.66 × 92°, respectively, showing induction of mild with-the-rule astigmatism. The difference between the amount of SIA at 1.5 and 3 months after surgery was small. Conclusion: In the MSICS, the X-pattern sutures were preferred to the horizontal sutures in the patients without significant preoperative steepening in line with the central meridian of the incision. In the cases with significant preoperative steepening, sutureless surgery or horizontal sutures were preferred. Corneal astigmatism in the patients undergoing MSICS was stable at 1.5 months after the surgery.

  5. Evaluation of a new wound closure device for linear surgical incisions: 3M Steri-Strip S Surgical Skin Closure versus subcuticular closure.

    Science.gov (United States)

    Kerrigan, Carolyn L; Homa, Karen

    2010-01-01

    Technological innovations are often adopted before scientific comparison to an accepted standard. The authors' study compared suture with a new coaptive film device, 3M Steri-Strip S Surgical Skin Closure, on linear incisions. Patients undergoing Wise-pattern breast reduction or abdominal procedures had paired incisions randomly assigned to Steri-Strip S or suture closure. Key outcome measures were closure time, patient comfort, and scar quality at 6 months by patients and surgeons using a new scar evaluation tool, visual assessment of linear scars. Statistical differences between the two closure techniques were assessed by Wilcoxon signed rank test. Of 59 patients, eight were excluded from randomization (a surgeon judged Steri-Strip S to be a nonviable closure technique for mismatched wound edges). Fifty-one patients (breast, n = 24; abdomen, n = 27) were randomized. Operative time with Steri-Strip S for breast was 2.0 minutes (SD = 1.1) versus suture closure at 4.6 minutes (SD = 1.5; p Strip S versus suture for the abdomen was faster (p Strip S and better at 2.6 (SD = 2.9) for suture (p = 0.008). One surgeon rated breast Steri-Strip S scars worse than suture scars (4.3 versus 3.7; p = 0.014). For abdominal scars, there was no difference in the patient or surgeon ratings. Steri-Strip S permits faster wound closure than suture. On the basis of patient reports of comfort and scar quality, surgeons increase efficiency and maintain quality with the use of Steri-Strip S on abdominal wounds but not on breast wounds.

  6. Timing of ectocranial suture activity in Gorilla gorilla as related to cranial volume and dental eruption.

    Science.gov (United States)

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2011-05-01

    Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society of Great Britain and Ireland.

  7. Optimal Suturing Technique and Number of Sutures for Surgical Implantation of Acoustic Transmitters in Juvenile Salmonids

    Energy Technology Data Exchange (ETDEWEB)

    Deters, Katherine A.; Brown, Richard S.; Boyd, James W.; Eppard, M. B.; Seaburg, Adam

    2012-01-02

    The size reduction of acoustic transmitters has led to a reduction in the length of incision needed to implant a transmitter. Smaller suture knot profiles and fewer sutures may be adequate for closing an incision used to surgically implant an acoustic microtransmitter. As a result, faster surgery times and reduced tissue trauma could lead to increased survival and decreased infection for implanted fish. The objective of this study was to assess the effects of five suturing techniques on mortality, tag and suture retention, incision openness, ulceration, and redness in juvenile Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Suturing was performed by three surgeons, and study fish were held at two water temperatures (12°C and 17°C). Mortality was low and tag retention was high for all treatments on all examination days (7, 14, 21, and 28 days post-surgery). Because there was surgeon variation in suture retention among treatments, further analyses included only the one surgeon who received feedback training in all suturing techniques. Incision openness and tissue redness did not differ among treatments. The only difference observed among treatments was in tissue ulceration. Incisions closed with a horizontal mattress pattern had more ulceration than other treatments among fish held for 28 days at 17°C. Results from this study suggest that one simple interrupted 1 × 1 × 1 × 1 suture is adequate for closing incisions on fish under most circumstances. However, in dynamic environments, two simple interrupted 1 × 1 × 1 × 1 sutures should provide adequate incision closure. Reducing bias in survival and behavior tagging studies is important when making comparisons to the migrating salmon population. Therefore, by minimizing the effects of tagging on juvenile salmon (reduced tissue trauma and reduced surgery time), researchers can more accurately estimate survival and behavior.

  8. Glottic closure patterns: type I thyroplasty versus type I thyroplasty with arytenoid adduction.

    Science.gov (United States)

    Li, Anya J; Johns, Michael M; Jackson-Menaldi, Cristina; Dailey, Seth; Heman-Ackah, Yolanda; Merati, Albert; Rubin, Adam D

    2011-05-01

    The goal of laryngeal framework surgery in patients with unilateral vocal fold paralysis is to improve glottic closure by medializing the paralyzed vocal fold. Type I thyroplasty (Th) and arytenoid adduction (AA) are two of the most commonly performed procedures. Two of the main rationales for performing an AA are to improve closure of the posterior glottis and correct vertical height discrepancy. The purpose of this study was to evaluate if AA with Th yields better posterior glottic closure and vertical height equality than Th alone. Retrospective. Using visual analog scales, three blinded reviewers evaluated glottic closure patterns in patients who underwent Th or Th with AA. Pre- and postoperative videostroboscopic examinations of 45 patients with unilateral vocal fold paralysis, who underwent laryngeal framework surgery, were evaluated. No significant difference was identified in postoperative scores for midmembranous glottis closure (P=0.282), closure just anterior to the vocal processes (P=0.426), respiratory glottis closure (P=0.158), or vertical height discrepancy (P=0.113). Although larger glottic gaps and vertical height discrepancies may lead some surgeons to predict that an AA is warranted, the usefulness of AA may not always be related to these parameters. Ultimately, voice improvement and not geometry should guide the surgeon's decision making. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  9. Torsion of monofilament and polyfilament sutures under tension decreases suture strength and increases risk of suture fracture.

    LENUS (Irish Health Repository)

    Hennessey, D B

    2012-08-01

    A continuous running suture is the preferential method for abdominal closure. In this technique the suture is secured with an initial knot and successive tissue bites are taken. At each tissue bite, the needle is rotated through the tissue; in doing so, the suture can twist around the knot which acts as an anchor.

  10. Articulation proficiency and error pattern of cleft palate children with delayed hard palate closure.

    Science.gov (United States)

    Wu, J; Chen, Y R; Noordhoff, M S

    1988-07-01

    Prior to 1982, children with cleft palate received delayed hard palate closure at Chang Gung Memorial Hospital. In this treatment, soft palate is usually repaired with Widmaier palatoplasty at about 18 months with surgery; hard palate is not closed until the age of 6 or 7. Our previous study indicated that the articulation skill of the cleft palate children before delayed hard palate closure is generally far inferior to the non-cleft children of the same age. Further investigation was carried out to look into the articulation proficiency and error patterns of the cleft palate children undergoing delayed hard palate closure. Data of 47 children (32 boys, 15 girls) were analyzed. Articulation proficiency was compared in four phoneme categories: nasals, plosives, fricatives and affricates. The results indicated that affricates are most difficult for Chinese cleft palate children to pronounce. At age 5, just before the hard palate closure, none of the phonemes is produced correctly except nasals.

  11. Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial.

    Science.gov (United States)

    Terasaka, Shunsuke; Taoka, Toshiaki; Kuroda, Satoshi; Mikuni, Nobutaka; Nishi, Toru; Nakase, Hiroyuki; Fujii, Yukihiko; Hayashi, Yasuhiko; Murata, Jun-Ichi; Kikuta, Ken-Ichiro; Kuroiwa, Toshihiko; Shimokawa, Sachie; Houkin, Kiyohiro

    2017-05-01

    The objective of this study is to evaluate the efficacy and safety of non-suture dural closure using a novel dural substitute (GM111) consisting of polyglycolic acid felt with a fibrin-glue-coated area commensurate in size with the dural defect. This was a non-controlled, open-label, multicenter clinical trial. The efficacy evaluation endpoints were (1) GM111's intra-operative capability to close dural defects and (2) prevention of cerebrospinal fluid (CSF) leakage and subcutaneous CSF retention throughout the postoperative period (evaluated by diagnostic imaging). Patients meeting the following three preoperative and two intra-operative selection criteria were enrolled: (1) between 12 and dura is surmised to be defective and in need of reconstruction; (3) informed written consent was obtained from the patient; (4) the surgical wound is class 1; and (5) the size of duraplasty is ≥0.2 cm(2) to water infusion, etc., in all patients. CSF leakage and subcutaneous CSF retention throughout the postoperative period were found in four patients. Adverse events for which a causal relationship with GM111 could not be ruled out occurred in 8.8% of the patients. There were no instances of postoperative infection due to GM111. GM111 showed good closure capability and safety when used for non-suture dural closure.

  12. A Biomechanical Comparison of Modified Krackow and Locking Loop Suture Patterns for Soft-Tissue Graft Fixation.

    Science.gov (United States)

    Ostrander, Roger V; Saper, Michael G; Juelson, Timothy J

    2016-07-01

    The purpose of this ex vivo biomechanical study was to evaluate the tensile mechanical properties of 2 modified suture-graft constructs regarding elongation after pre-tensioning and cyclic loading as well as load to failure. Thirty fresh-frozen porcine Achilles tendons were randomly divided into 2 groups of 15 specimens to assess elongation of the suture-graft construct across 2 different tendon-grasping techniques: a modified locking SpeedWhip (MLS) stitch and a modified Krackow (MK) stitch. Each tendon was pre-tensioned to 89 N for 10 minutes and then cyclically loaded to 200 N for 200 cycles. Finally, each tendon was loaded to failure. After being pre-tensioned, the MK group elongated significantly more than the MLS group (7.12 ± 0.95 mm v 6.26 ± 0.94 mm, P = .02). Elongation after cyclic loading for the MK and MLS groups was not significantly different (3.39 ± 0.95 mm and 3.21 ± 0.93 mm, respectively; P > .05). The MK group showed a significantly larger load to failure compared with the MLS group (689 ± 61 N v 604 ± 46 N, P = .000024). The mean tendon cross-sectional area was larger in the MK group (399 ± 5 mm(2)v 393 ± 8 mm(2), P = .02), but this difference did not relate to the amount of elongation or load to failure. All but 1 specimen failed by suture breakage at the square knot. The MLS and MK stitches, pre-tensioned to 89 N for 10 minutes, both effectively minimized suture-graft construct elongation after cyclic loading. Consequently, both suture patterns are recommended for soft-tissue graft fixation. The MLS and MK suture configurations may provide sufficient biomechanical fixation of the tendon graft in the clinical setting of soft-tissue fixation without an interference screw. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Nickel-Titanium Wire as Suture Material: A New Technique for the Fixation of Skin.

    Science.gov (United States)

    Li, Haidong; Song, Tao

    2018-01-29

    To introduce nickel-titanium wire as suture material for closure of incisions in cleft lip procedures. Closure of skin incisions using nickel-titanium wire as suture material, with postoperative follow-up wound evaluation. There was excellent patient satisfaction and good cosmetic outcome. Nickel-titanium wire is an excellent alternative for suture closure of cleft lip surgical incisions.

  14. Evaluation of opening pattern and bone neoformation at median palatal suture area in patients submitted to surgically assisted rapid maxillary expansion (SARME through cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Daniel Gomes SALGUEIRO

    2015-08-01

    Full Text Available AbstractSurgically assisted rapid maxillary expansion (SARME is the treatment of choice to adult patients even with severe transversal maxillary discrepancies. However, the adequate retention period to achieve the bone remodeling, thus assuring treatment stability, is controversial.Objective To evaluate the opening pattern and bone neoformation process at the midpalatal suture in patients submitted to surgically assisted (SARME through cone beam computed tomography (CBCT.Material and Methods Fourteen patients were submitted to SARME through subtotal Le Fort I osteotomy. Both the opening pattern and the mean bone density at midpalatal suture area to evaluate bone formation were assessed pre- and post-operatively (15, 60 and 180 days through CBCT.Results Type I opening pattern (from anterior to posterior nasal spine occurred in 12 subjects while type II opening pattern (from anterior nasal spine to transverse palatine suture occurred in 2 individuals. The 180-day postoperative mean (PO 180 of bone density value was 49.9% of the preoperative mean (Pre value.Conclusions The opening pattern of midpalatal suture is more related to patients’ age (23.9 years in type I and 33.5 years in type II and surgical technique. It was not possible to observe complete bone formation at midpalatal suture area at the ending of the retention period studied (180 days.

  15. Modified Superior-Based Pharyngeal Flap Is Effective in Treatment of Velopharyngeal Insufficiency Regardless of the Preoperative Closure Pattern.

    Science.gov (United States)

    Ekin, Omer; Calis, Mert; Kulak Kayikci, Mavis Emel; Icen, Mehtap; Gunaydin, Riza Onder; Ozgur, Figen

    2017-03-01

    Velopharyngeal insufficiency (VPI) is certainly one of the most important problems confronted after cleft palate repairs. In this study, it was aimed to evaluate the preoperative and postoperative speaking results of patients who underwent modified superior-based pharyngeal flap. Sixty-six children who underwent modified superiorly based pharyngeal flap for treatment of VPI between 2005 and 2013 were retrospectively reviewed. The study population was evaluated in 2 distinctive groups depending on their preoperative velopharyngeal closure pattern as: coronal closure pattern or noncoronal closure patterns (ie, circular, sagittal with or without the presence of a Passavant ridge). The speech outcome of the patients was evaluated using the objective assessment tools of nasopharyngoscopy and nasometer. Coronal closure pattern was determined in 24 patients (36.4%) and noncoronal closure pattern in 42 patients (63.6%). The mean follow-up period was 14.67 ± 3.90 and 13.74 ± 3.53 months in the coronal and noncoronal groups, respectively. The results demonstrated that the postoperative nasalance scores of all syllables except (m) and (n) were found to be significantly lower compared to those of the preoperative period (P < 0.001). However, no significant difference between the preoperative and postoperative results was observed in means of closure pattern. The surgical approach of modified superior-based pharyngeal flap for treatment of VPI appears to be effective regardless of the preoperatively determined closure pattern.

  16. Suture materials - Current and emerging trends.

    Science.gov (United States)

    Dennis, Christopher; Sethu, Swaminathan; Nayak, Sunita; Mohan, Loganathan; Morsi, Yosry Yos; Manivasagam, Geetha

    2016-06-01

    Surgical sutures are used to facilitate closure and healing of surgical- or trauma-induced wounds by upholding tissues together to facilitate healing process. There is a wide range of suture materials for medical purpose and the main types include absorbable and nonabsorbable. Recently, there is a growth in the development of classes of suture materials based on their properties and capabilities to improve tissue approximation and wound closure. This review outlines and discusses the current and emerging trends in suture technology including knotless barbed sutures, antimicrobial sutures, bio-active sutures such as drug-eluting and stem cells seeded sutures, and smart sutures including elastic, and electronic sutures. These newer strategies expand the versatility of sutures from being used as just a physical entity approximating opposing tissues to a more biologically active component enabling delivery of drugs and cells to the desired site with immense application potential in both therapeutics and diagnostics. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1544-1559, 2016. © 2016 Wiley Periodicals, Inc.

  17. Mesh Sutured Repairs of Abdominal Wall Defects

    Science.gov (United States)

    Lanier, Steven T.; Jordan, Sumanas W.; Miller, Kyle R.; Ali, Nada A.; Stock, Stuart R.

    2016-01-01

    Background: A new closure technique is introduced, which uses strips of macroporous polypropylene mesh as a suture for closure of abdominal wall defects due to failures of standard sutures and difficulties with planar meshes. Methods: Strips of macroporous polypropylene mesh of 2 cm width were passed through the abdominal wall and tied as simple interrupted sutures. The surgical technique and surgical outcomes are presented. Results: One hundred and seven patients underwent a mesh sutured abdominal wall closure. Seventy-six patients had preoperative hernias, and the mean hernia width by CT scan for those with scans was 9.1 cm. Forty-nine surgical fields were clean-contaminated, contaminated, or dirty. Five patients had infections within the first 30 days. Only one knot was removed as an office procedure. Mean follow-up at 234 days revealed 4 recurrent hernias. Conclusions: Mesh sutured repairs reliably appose tissue under tension using concepts of force distribution and resistance to suture pull-through. The technique reduces the amount of foreign material required in comparison to sheet meshes, and avoids the shortcomings of monofilament sutures. Mesh sutured closures seem to be tolerant of bacterial contamination with low hernia recurrence rates and have replaced our routine use of mesh sheets and bioprosthetic grafts. PMID:27757361

  18. Experimental study of the characteristics of a novel mesh suture.

    Science.gov (United States)

    Dumanian, G A; Tulaimat, A; Dumanian, Z P

    2015-09-01

    The failure of sutures to maintain tissue in apposition is well characterized in hernia repairs. A mesh suture designed to facilitate tissue integration into and around the filaments may improve tissue hold and decrease suture pull-through. In vitro, the sutures were compared for resistance to pull-through in ballistics gel. In vivo, closure of midline laparotomy incisions was done with both sutures in 11 female pigs. Tissue segments were subsequently subjected to mechanical and histological testing. The mesh suture had tensile characteristics nearly identical to those of 0-polypropylene suture. Mesh suture demonstrated greater resistance to pull-through than standard suture (mean(s.d.) 4.27(0.42) versus 2.23(0.48) N; P suture (320(57) versus 160(56) N; P suture. Histological examination at 8 and 90 days showed complete tissue integration of the mesh suture. The novel mesh suture structure increased the strength of early wound healing in an experimental model. Surgical relevance Traditional sutures have the significant drawback of cutting and pulling through tissues in high-tension closures. A new mesh suture design with a flexible macroporous outer wall and a hollow core allows the tissues to grow into the suture, improving early wound strength and decreasing suture pull-through. This technology may dramatically increase the reliability of high-tension closures, thereby preventing incisional hernia after laparotomy. As suture pull-through is a problem relevant to all surgical disciplines, numerous additional indications are envisioned with mesh suture formulations of different physical properties and materials. © 2015 The Authors. BJS published by John Wiley & Sons Ltd on behalf of BJS Society Ltd.

  19. Running sutures anchored with square knots are unreliable.

    Science.gov (United States)

    Aanning, H L; Van Osdol, Andrew; Allamargot, Chantal; Becker, Brandt E; Howard, Thomas C; Likness, Micah L; Merkwan, Courtney E; Tarver, Dan D

    2012-09-01

    A previous study showed that running polypropylene sutures anchored with square knots retain only 75% of their strength compared with half hitches. The aim of this study was to investigate whether anchor knot geometry similarly affects the tensile strength of other types of sutures used in continuous closures. Monofilament and multifilament sutures (all 3-0) were anchored with either square knots or half hitches to 1 tensionometer post, and the running ends were secured to the other. The force required to break the running suture and the site of suture failure were recorded. The running sutures anchored with square knots retained only 50% to 84% of the strength of the identical sutures secured with half hitches (P suture anchored with half hitches is stronger and safer in comparison with the same suture anchored with square knots. This study provokes a fundamental reconsideration of the use of square knots to anchor running sutures. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. [Calculating the induced, computerized tomography measured corneal astigmatism after cataract surgery with small incision technique and wound closure with single suture technique based on various mathematical models].

    Science.gov (United States)

    Rauber, M; Grewing, R; Mester, U

    1993-08-01

    Small-incision cataract surgery with scleral tunnel incision and one-stitch horizontal or sutureless wound closure has been found to be an effective way to reduce postoperative astigmatism and to guarantee greater stability of the wound with rapid visual rehabilitation. In some studies surgically induced astigmatism by different wound constructions and wound-closure techniques has been compared to determine the astigmatism induced. Different calculation methods were used leading to different results. Therefore, we evaluated the induced astigmatism in 50 patients operated on by scleral tunnel incision, phacoemulsification with PCL implantation and single-stitch wound closure. We analyzed induced astigmatism on the first postoperative day and 3 months postoperatively by different methods: the simple subtraction method (0.91 and 0.30 D), Naeser's polar value method (-0.74 and -0.75 D), the vector analysis method of Jaffe (2.53 and 1.19 D) and two calculations described by Cravy. Depending on the formula used, different results were obtained. The subtraction method disregards axis change and is less precise. The vector analysis methods obtain the highest values for induced astigmatism and seem to be the most precise for evaluating the real amount of induced postoperative astigmatism.

  1. Intrastromal corneal suture for small incision cataract surgery.

    Science.gov (United States)

    Chipont Benabent, E; Artola Roig, A; Martínez Toldos, J J

    1996-01-01

    Proper wound closure is important in preventing postoperative endophthalmitis. We developed an intrastromal corneal suture technique that uses some principles of the running, locked, intradermal suture for light-tension skin wounds. It achieves close approximation of the wound edges, reduces postoperative wound care and the risk of wound infection in clean surgical wounds, and obviates suture removal. It may also help prevent endophthalmitis and early against-the-rule astigmatism without the complications associated with external suture exposure.

  2. Skin closure after groin hernia repair in children: a comparative ...

    African Journals Online (AJOL)

    Skin closure after groin hernia repair in children: a comparative study of three suture materials and two suture techniques La fermeture de la peau après la réparation de l'hernie de l'aine chez les enfants: une étude comparative de trois matériaux de suture et de deux techniques de suture.

  3. The suture pullout characteristics of human and porcine linea alba.

    Science.gov (United States)

    Cooney, Gerard M; Lake, Spencer P; Thompson, Dominic M; Castile, Ryan M; Winter, Des C; Simms, Ciaran K

    2017-04-01

    There is a substantial prevalence of post-operative incisional hernia for both laparoscopic and laparotomy procedures, but there have been few attempts at quantifying abdominal wound closure methodology in the literature. One method to ascertain a more robust method of wound closure is the identification of the influence of suture placement parameters on suture pullout force. Current surgical practice involves a recommended bite depth and bite separation of 10mm, but the evidence base for this is not clear. In this paper, the suture pullout characteristics of both porcine and human linea alba were investigated to ascertain a suture placement protocol for surgical wound closure. Uniaxial suture pullout force testing on fresh frozen porcine and human linea alba samples was performed using standard materials testing machines. The influence of the number of suture loops, the bite depth and the bite separation of the sutures and the orientation of the sutures with respect to the principal fibre direction in the linea alba were assessed. Results showed a clearly identifiable relationship between pullout force of the suture, bite separation and bite depth, with low suture separation and high suture depth as optimal parameters for increasing pullout force. Resistance to pullout could be improved by as much as 290% when optimizing test conditions. Both human and porcine tissue were observed to exhibit very similar pullout force characteristics, corroborating the use of a porcine model for investigations into wound closure methodology. Orientation of suture application was also found to significantly affect the magnitude of suture pullout, with suturing applied longitudinally across a transverse defect resulting in higher pullout forces for small suture bite separations. Although further assessment in an environment more representative of in vivo conditions is required, these findings indicate that increasing the bite depth and reducing the bite separation with respect to

  4. Performance Assessment of Bi-Directional Knotless Tissue-Closure Devices in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters, 2009 - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.

    2012-11-09

    The purpose of this report is to assess the performance of bi-directional knotless tissue-closure devices for use in tagging juvenile salmon. This study is part of an ongoing effort at Pacific Northwest National Laboratory (PNNL) to reduce unwanted effects of tags and tagging procedures on the survival and behavior of juvenile salmonids, by assessing and refining suturing techniques, suture materials, and tag burdens. The objective of this study was to compare the performance of the knotless (barbed) suture, using three different suture patterns (treatments: 6-point, Wide “N”, Wide “N” Knot), to the current method of suturing (MonocrylTM monofilament, discontinuous sutures with a 2×2×2×2 knot) used in monitoring and research programs with a novel antiseptic barrier on the wound (“Second Skin”).

  5. The history and evolution of sutures in pelvic surgery

    Science.gov (United States)

    Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D

    2011-01-01

    Summary The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool. PMID:21357979

  6. Clamp fixation to prevent unfolding of a suture knot decreases tensile strength of polypropylene sutures.

    Science.gov (United States)

    Türker, Mehmet; Yalçinozan, Mehmet; Çirpar, Meriç; Çetik, Özgür; Kalaycioğlu, Barış

    2012-12-01

    Although sutures evolved in last decade and the product spectrum broadened largely, they can be still classified into two: monofilament and multifilament. Sutures are the mainstay of orthopedic procedures like fascial closures, tendon repairs or tenodesis. In every repair, a suture loop is created. This suture loop is prone to failure due to suture elongation, knot slip and suture breakage. As the knot is the stress riser in a suture loop, the majority of acute loop failure occurs just adjacent to the knot. Monofilament sutures have higher bending stiffness and tendency to untie than multifilament sutures. The first throw of monofilament sutures have tendency to untie, which decrease loop tension and result in loss of achieved tissue approximation. Although a common practice is to fix the first throw via a clamp before the locking one is tied, it can be hypothesized that a potential deforming effect can lead to a decrease in ultimate failure load of a monofilament suture loop. Fixing the first throw significantly reduced the ultimate failure load of monofilament nonabsorbable polypropylene sutures (Prolene) (62.2 ± 8 N vs. 72.7 ± 9 N, p = 0.019). The ultimate failure load achieved by monofilament sutures Polyglyconate (Maxon) and Nylon (Ethilon) and braided absorbable Polyglactin (Vicryl) were not affected by fixing the first throw. Under microscopic examination, polypropylene sutures were found to be deformed by clamp fixation, while the others were not. Polypropylene sutures can be easily damaged when it is fixed by a clamp during knot tying. Presented data demonstrated that in real surgical situations clamp fixation of polypropylene knots can damage the suture loop and carry the risk of acute failure of repair site during early rehabilitation.

  7. Suture choice matters in rabbit model of laparoscopic, preperitoneal, inguinal hernia repair.

    Science.gov (United States)

    Kelly, Katherine B; Krpata, David M; Blatnik, Jeffrey A; Ponsky, Todd A

    2014-06-01

    We evaluated the effect of different suture materials in a laparoscopic preperitoneal ligation of the patent processus vaginalis in a rabbit survival model. New Zealand White rabbits underwent laparoscopic assisted preperitoneal ligation of the patent processus vaginalis. The processus vaginalis was closed with silk (n=10), polyglactin 910 (Vicryl(®); Ethicon, a Johnson & Johnson Company, Somerville, NJ) (n=10), or polypropylene (Prolene(®); Ethicon) (n=10). At necropsy, the suture was removed, and repair integrity was evaluated. All rabbits survived to necropsy without complications. No suture material was identified during necropsy of the Vicryl group. Eight (80%) of the Vicryl closures failed, with six (60%) failing at initial inspection. Following removal of suture material, nine (90%) of the Prolene closures failed, and only one (10%) of the silk closures failed (P=.009). The silk suture resulted in an improved closure rate. Ligation with silk suture probably incited an increased inflammatory response that likely created a scar while persisting long enough for the scar to become established. In contrast, the Vicryl sutures probably failed because the sutures dissolved before a scar was able to fully develop. Finally, the Prolene closures were suture dependent as evidenced by failure when the suture was removed. Nonabsorbable braided suture may improve closure of pediatric indirect inguinal hernias during laparoscopic-assisted preperitoneal ligation.

  8. Analysis of nerve and neuropeptide patterns in vacuum-assisted closure-treated diabetic murine wounds.

    Science.gov (United States)

    Younan, George; Ogawa, Rei; Ramirez, Michelle; Helm, Douglas; Dastouri, Pouya; Orgill, Dennis P

    2010-07-01

    Reestablishment of the peripheral nervous system occurs in parallel with wound healing. With accelerated wound healing seen with the vacuum-assisted closure device, the authors studied its effects on nerve fiber regeneration, nerve sprouting, and the stimulation of neuropeptides and neurotrophins. A vacuum-assisted closure device was applied to a full-thickness diabetic mouse wound using continuous or cyclical modes and compared with foam dressing or occlusive dressing controls, using 10 mice per group. Nerve fibers, substance P, calcitonin gene-related peptide, and nerve growth factor were analyzed using two-dimensional immunohistochemistry and real-time reverse-transcriptase polymerase chain reaction. A significant increase in dermal and epidermal nerve fiber densities and in substance P, calcitonin gene-related peptide, and nerve growth factor expression was seen in vacuum-assisted closure-treated wounds. Cyclical treatment mode correlated with the largest increase in granulation tissue production, wound surface microdeformations, and a slightly faster wound closure rate. This study suggests that vacuum-assisted closure therapy can modulate nerve fiber and neuropeptide production in the wound. Optimized kinetics of vacuum-assisted closure application may provide an opportunity for clinicians to further improve wound healing in denervated wounds such as pressure sores and diabetic foot ulcerations.

  9. Mechanical properties of various suture materials and placement patterns tested with surrogate in vitro model constructs simulating laryngeal advancement tie-forward procedures in horses.

    Science.gov (United States)

    Santos, Marcos P; Gutierrez-Nibeyro, Santiago D; Horn, Gavin P; Johnson, Amy J Wagoner; Stewart, Matthew C; Schaeffer, David J

    2014-05-01

    To compare the mechanical properties of laryngeal tie-forward (LTF) surrogate constructs prepared with steel fixtures and No. 5 braided polyester or braided polyethylene by use of a standard or a modified suture placement technique. 32 LTF surrogate constructs. Surrogate constructs were prepared with steel fixtures and sutures (polyester or polyethylene) by use of a standard or modified suture placement technique. Constructs underwent single-load-to-failure testing. Maximal load at failure, elongation at failure, stiffness, and suture breakage sites were compared among constructs prepared with polyester sutures by means of the standard (n = 10) or modified (10) technique and those prepared with polyethylene sutures with the standard (6) or modified (6) technique. Polyethylene suture constructs had higher stiffness, higher load at failure, and lower elongation at failure than did polyester suture constructs. Constructs prepared with the modified technique had higher load at failure than did those prepared with the standard technique for both suture materials. All sutures broke at the knot in constructs prepared with the standard technique. Sutures broke at a location away from the knot in 13 of 16 constructs prepared with the modified technique (3 such constructs with polyethylene sutures broke at the knot). Results suggested LTF surrogate constructs prepared with polyethylene sutures or the modified technique were stronger than those prepared with polyester sutures or the standard technique.

  10. Uterine incision cloSure at caesarean section: A randomised ...

    African Journals Online (AJOL)

    nylon suture size 0. The only difference between the two groups was on the method of closure of uterine incision i.e. intraperitoneal closure or closure after temporary exteriorisation. Intraperitoneal closure. After delivery of the baby and the placenta, the uterine incision is closed with the uterus within the abdominal cavity.

  11. RESEARCH A randomised controlled trial of suture materials used ...

    African Journals Online (AJOL)

    A variety of suture materials and skin staples (SS) are used for skin closure after caesarean section (CS). Some of these suture materials have been associated with lower wound infection rates, reduced pain, improved cosmetic outcomes and cost-effectiveness.1 On the other hand, SS are easier to use and are associated ...

  12. Postoperative washing of sutured wounds

    Directory of Open Access Journals (Sweden)

    Conrad Harrison

    2016-11-01

    Full Text Available A best evidence topic was written according to the structured protocol. The three part question addressed was: [In patients undergoing closure of surgical wounds with sutures] does [keeping the wound dry for the first 48 h after closure] [reduce the incidence of surgical site infections (SSIs]? 4 relevant papers were culled from the literature and appraised. The authors, date, country, population, study type, main outcomes, key results and study weaknesses were tabulated. Current NICE guidelines recommend cleaning surgical wounds with sterile saline only for the first 48 h following skin closure. We found no evidence that washing wounds with tap water during this period increases the incidence of SSIs compared to keeping them dry. Further randomised controlled trials will enable the construction of conclusive systematic reviews and meta-analyses.

  13. Torsion of monofilament and polyfilament sutures under tension decreases suture strength and increases risk of suture fracture.

    Science.gov (United States)

    Hennessey, D B; Carey, E; Simms, C K; Hanly, A; Winter, D C

    2012-08-01

    A continuous running suture is the preferential method for abdominal closure. In this technique the suture is secured with an initial knot and successive tissue bites are taken. At each tissue bite, the needle is rotated through the tissue; in doing so, the suture can twist around the knot which acts as an anchor. To determine the effect of axial torsional forces on sutures used in abdominal closure. The effect of axial twisting on polydioxanone (PDS*II), polyglactin (Vicryl), polypropylene (Prolene) and nylon (Ethilon) sutures was investigated using a uniaxial testing device. The maximum tensile force withstood for untwisted sutures was determined: polydioxanone failed at a tensile force of 116.4±0.84 N, polyglactin failed at 113.9±2.4 N, polypropylene failed at 71.1±1.5 N and nylon failed at 61.8±0.5 N. Twisting decreased the maximum tensile force of all sutures; one complete twist per 10 mm (i.e., 15 twists) decreased the tensile strength of polydioxanone by 21%, polyglactin by 23%, polypropylene by 16% and nylon by 13%, psuture strength, with one twist per 75 mm (i.e., 20 twists) of polydioxanone decreasing strength by 39%, Psutures is a previously unrecognised phenomenon. Surgeons should be aware that this can result in a decrease in suture strength and reduce the elasticity of the material, and therefore need to adapt their practice to reduce the torsional force placed on sutures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. A Comparison of Barbed Sutures and Standard Sutures with regard to Wound Cosmesis in Panniculectomy and Reduction Mammoplasty Patients

    Directory of Open Access Journals (Sweden)

    Kristen Aliano

    2016-01-01

    Full Text Available Cosmesis is a vital concern for patients undergoing plastic and reconstructive surgery. Many variations in wound closure are employed when attempting to minimize a surgical scar’s appearance. Barbed sutures are one potential method of achieving improved wound cosmesis and are more common in recent years. To determine if barbed sutures differ from nonbarbed in wound cosmesis, we conducted a single-blinded, randomized, controlled trial of 18 patients undergoing bilateral reduction mammoplasty or panniculectomy. Patients were their own controls, receiving barbed sutures on one side and standard sutures on the contralateral side. Surgical scars were evaluated postoperatively by patient preference self-assessment and an observer. Ten patients were evaluated at 3 months postoperatively, yielding a mean Stony Brook Scar Evaluation Scale (SBSES rating of 4.4 for barbed suture and 3.5 for regular suture (p=0.15. At 6 months, 8 patients performed self-assessment to determine their preference; 4 preferred the barbed sutures, 1 preferred the regular sutures, and 3 had no preference. Further research with larger sample sizes is needed to determine if barbed sutures convey any advantage over standard sutures in wound healing. However, our results suggest that barbed sutures are a reasonable alternative to standard sutures particularly with regard to wound cosmesis.

  15. Coordination of respiration and swallowing: functional pattern and relevance of vocal folds closure

    Directory of Open Access Journals (Sweden)

    Milton Melciades Barbosa Costa

    2010-03-01

    Full Text Available CONTEXT: Breathing and swallowing coordination, despite the expressive number of study, remain as theme deserving further research. OBJECTIVE: To identify a coordination pattern between swallowing and the natural breathing pause that occur in association with it (swallowing apnea and also the relevance of the vocal folds closure in this process. METHODS: Sixty-six adults, male and female, including normal health people, post-laryngectomy individuals and patients with digestive complaints without dysphagia were analyzed. The respiratory air flux interruptions produced by wet requested swallows and dry, requested and spontaneous swallows, were registered using thermo and piezoelectric receptors coupled to synectics medical manometry equipment, using Polygram upper 4.21 software. The results were analyzed with the Chi-square (3×2 and (2×2 nonparametric independency test with P = 0.05. RESULTS: Swallowing apnea is a preventive breathing stop that start just before and stay present during all deglutition pharyngeal phase. It is a well coordinated phenomena that occur as pattern in association with low elastic resistance of the lung, on the expiratory final phase until inspiration initial phase. This breathing stoppage it is usually followed by a short expiraton preceding a new breathing cycle. The swallow apnea and vocal folds closure are both independents mechanisms. CONCLUSION: It is possible to suppose that in the subconscious condition, swallowing apnea is integrated under coordination of the same control mechanism that also involves the elastic resistance of the lung.CONTEXTO: Apesar do expressivo número de estudos sobre a coordenação da respiração com a deglutição, o tema permanece aberto à pesquisa. OBJETIVO: Identificar um padrão de coordenação entre a pausa respiratória e a deglutição que ocorre em associação a esta usual apneia (apneia de deglutição e estabelecer a importância do fechamento das pregas vocais que ocorre

  16. A novel option of uninterrupted closure of surgical wounds

    Directory of Open Access Journals (Sweden)

    Sulamanidze Marlen

    2009-01-01

    Full Text Available Background : A cosmetically pleasing postoperative scar is an important aim of all aesthetic surgeries. Use of proper suture materials for delicate and gentle suturing of the operative injury is an important requirement for achieving satisfactory scars. However, closure of the edges of wounds by means of conventional suture materials does not always meet the requirements to achieve this objective. Aim : To simplify and facilitate the process of surgical wound closure, to improve the quality of scar, and to achieve a good cosmetic effect through the introduction of a new type of suture material. Materials and Methods : We have introduced a new surgical suturing material-a nontraumatic, barbed thread connected with the suture needle-APTOS SUTURE (European patent 1075843 as of 1999. Presented herein is a new modification of the technique of uninterrupted subcutaneous and intracutaneous suturing of wound edges, and the details of our experience with this material. Results : Our experience shows that, with use of APTOS, wound closure is carried out easily and quickly. The wound remains stable, the time of healing is shortened, and the process of suture removal is simplified, resulting in an aesthetically pleasing scar. Conclusions : The technique of surgical wound suturing proposed herein is a simple, facilitated, and efficient option of wound-edge closure, which can successfully be used, both in general and in aesthetic surgery for wound closure, such as plasty of scars, face lift, mammoplasty, and abdominal plasty.

  17. Clinical Applications of Barbed Suture in Aesthetic Breast Surgery.

    Science.gov (United States)

    Mitchell, Ryan T M; Bengtson, Bradley P

    2015-10-01

    The breadth of literature regarding barbed suture applications in plastic surgical procedures and of importance to this article, barbed suture applications in breast surgery, is growing dramatically as surgical practitioners are becoming more familiar with the advantages of this new suture technology. Barbed suture devices were first implemented by plastic surgeons for the use in various minimally invasive techniques for facial rejuvenation, but have now surpassed these applications and are now much more commonly used in Breast and Body closures. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. The effect of windmill closure on the movement patterns of ungulates along the auob riverbed

    Directory of Open Access Journals (Sweden)

    M. G. L Mills

    1984-12-01

    Full Text Available Three groups of six consecutive windmills along the Auob riverbed were closed down for periods of one year and the responses of the three major ungulate species in the area to this practice were studied. The movements of springbok Antidorcas marsupialis and gemsbok Oryx gazella were not found to be affected by the windmill closure, but blue wildebeest Connochaetes taurinus showed significant tenden- cies to move out of areas in which windmills were closed.

  19. Comparison of two surgical suture techniques in uvulopalatopharyngoplasty and expansion sphincter pharyngoplasty.

    Science.gov (United States)

    Steinbichler, Teresa B; Bender, Birte; Giotakis, Aristeidis I; Dejaco, Daniel; Url, Christoph; Riechelmann, Herbert

    2018-02-01

    Uvulopalatopharyngoplasty (UPPP) and expansion sphincter pharyngoplasty (ESP) are two standard surgical procedures for treatment of snoring and sleep apnea. In a prospective clinical trial, we compared a standard simple interrupted suture technique for closure of the tonsillar pillars with a running locked suture. Each suture technique was randomly assigned either to the left or the right tonsillar pillars in 28 patients. During the first week, patients were daily checked for suture dehiscence and again on days 10 and 21, the end of followup. Time to perform the sutures was measured intraoperative and surgical complications were recorded. During followup, suture dehiscence was observed in 15/28 interrupted and 16/28 running sutures (p > 0.5). If a dehiscence occurred during the observation period, the median day of dehiscence was 10 (1 and 3 quartile: 5.75 and 17) days for the interrupted suture and 10 (5-11) days for the running locked suture technique (p > 0.05). The mean (± SD) surgical time for the interrupted suture was 5.2 ± 1.9 and 3.5 ± 1.8 min for the running locked suture (p sutures and 2/28 interrupted sutures. The running locked suture technique is an equally safe and time saving way of wound closure in UPPP and ESP.

  20. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial.

    Science.gov (United States)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati; Devi, Dipali; Kalita, Dhaneswar; Kalita, Kasturi; Dash, Suvakanta; Kotoky, Jibon

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  1. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial

    Energy Technology Data Exchange (ETDEWEB)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Devi, Dipali [Seri biotech laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Kalita, Dhaneswar [Government Ayurvedic College and Hospital, Jalukbari, Guwahati, Assam 781014 (India); Kalita, Kasturi [Department of Pathology, Hayat Hospital, Guwahati, Assam 781034 (India); Dash, Suvakanta [Girijananda Chowdhury Institute of pharmaceutical science, Azara, Guwahati, Assam 781017 (India); Kotoky, Jibon, E-mail: jkotoky@gmail.com [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India)

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  2. Suture materials and suture techniques used in tendon repair.

    Science.gov (United States)

    Ketchum, L D

    1985-02-01

    . The less traumatic suture techniques facilitate closure of the tendon sheath, which not only acts as a mechanical barrier to the ingrowth of extrasheath adhesion, which produces fibroblasts, but also re-establishes the continuity of the synovial fluid system, which is a major source of nutrition to the tendon. The healing tendon then can be thought of as a delicate structure, one not to be overmanipulated, traumatized, strangulated, or stretched.(ABSTRACT TRUNCATED AT 400 WORDS)

  3. A bidirectional interface growth model for cranial interosseous suture morphogenesis

    Science.gov (United States)

    Zollikofer, Christoph P E; Weissmann, John David

    2011-01-01

    Interosseous sutures exhibit highly variable patterns of interdigitation and corrugation. Recent research has identified fundamental molecular mechanisms of suture formation, and computer models have been used to simulate suture morphogenesis. However, the role of bone strain in the development of complex sutures is largely unknown, and measuring suture morphologies beyond the evaluation of fractal dimensions remains a challenge. Here we propose a morphogenetic model of suture formation, which is based on the paradigm of Laplacian interface growth. Computer simulations of suture morphogenesis under various boundary conditions generate a wide variety of synthetic sutural forms. Their morphologies are quantified with a combination of Fourier analysis and principal components analysis, and compared with natural morphological variation in an ontogenetic sample of human interparietal suture lines. Morphometric analyses indicate that natural sutural shapes exhibit a complex distribution in morphospace. The distribution of synthetic sutures closely matches the natural distribution. In both natural and synthetic systems, sutural complexity increases during morphogenesis. Exploration of the parameter space of the simulation system indicates that variation in strain and/or morphogen sensitivity and viscosity of sutural tissue may be key factors in generating the large variability of natural suture complexity. PMID:21539540

  4. Functional implications of dicynodont cranial suture morphology.

    Science.gov (United States)

    Jasinoski, Sandra C; Rayfield, Emily J; Chinsamy, Anusuya

    2010-06-01

    Cranial suture morphology of Lystrosaurus and the generalized dicynodont Oudenodon was investigated to determine the strain environment during mastication, which in turn may indicate a difference in cranial function between the two taxa. Finite element (FE) analysis indicated that less strain accumulated in the cranium of Lystrosaurus during orthal bite simulations than in Oudenodon. Despite the overall difference in strain magnitude, moderate to high FE-predicted strain accumulated in similar areas of the cranium of both taxa. The suture morphology in these cranial regions of Lystrosaurus and Oudenodon was investigated further by examination of histological sections and supplemented by observations of serial sections and computed tomography (CT) scans. The predominant type of strain from selected blocks of finite elements that contain sutures was determined, enabling comparison of suture morphology to strain type. Drawing from strain-suture correlations established in extant taxa, the observed patterns of sutural morphology for both dicynodonts were used to deduce cranial function. The moderate to high compressive and tensile strain experienced by the infraorbital bar, zygomatic arch, and postorbital bar of Oudenodon and Lystrosaurus may have been decreased by small adjustive movements at the scarf sutures in those regions. Disparities in cranial suture morphology between the two taxa may reflect differences in cranial function. For instance, the tongue and groove morphology of the postorbital-parietal suture in Oudenodon could have withstood the higher FE-predicted tensile strain in the posterior skull roof. The scarf premaxilla-nasal suture of Lystrosaurus provided an additional region of sutural mobility in the anterior surface of the snout, suggesting that Lystrosaurus may have employed a different biting regime than Oudenodon. The morphology of several sutures sampled in this study correlated with the FE-predicted strain, although other cranial functional

  5. Does Barbed Suture Lower Cost and Improve Outcome in Total Knee Arthroplasty? A Randomized Controlled Trial.

    Science.gov (United States)

    Chan, Vincent W K; Chan, Ping-Keung; Chiu, Kwong-Yuen; Yan, Chun-Hoi; Ng, Fu-Yuen

    2017-05-01

    Wound closure is key to prevent infection, facilitate immediate rehabilitation, and improve efficiency of total knee arthroplasty (TKA). Continuous knotless suturing with barbed suture can potentially save time and distribute tension more evenly. However, its role in TKA in terms of cost-effectiveness and wound complications is not clear. This study aims at comparing barbed and traditional sutures' wound closure time and cost in primary TKA. One hundred nine knees were randomized into either barbed or traditional group. Synthetic absorbable sutures (Vicryl, Ethicon Inc) and bidirectional barbed sutures (Stratafix, Ethicon Inc) were used. Arthrotomy and subcutaneous wound closure time, wound complications, and rehabilitation parameters in terms of range of motion and Knee Society Score were compared. Patients were followed up to 3 months. Traditional sutures had significantly more positive leak tests (10 vs 2, P value sutures (arthrotomy 325 seconds vs 491 seconds; subcutaneous 306 seconds vs 381 seconds, P value suture material and operation time, barbed suture on average saved USD 48.7 per TKA in our local institute. Bidirectional barbed suture improves the cost-effectiveness of TKA through reducing wound closure time and wound complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Cyanoacrylate for Intraoral Wound Closure: A Possibility?

    Directory of Open Access Journals (Sweden)

    Parimala Sagar

    2015-01-01

    Full Text Available Wound closure is a part of any surgical procedure and the objective of laceration repair or incision closure is to approximate the edges of a wound so that natural healing process may occur. Over the years new biomaterials have been discovered as an alternate to conventional suture materials. Cyanoacrylate bioadhesives are one among them. They carry the advantages of rapid application, patient comfort, resistance to infection, hemostatic properties, and no suture removal anxiety. Hence this study was undertaken to study the effect of long chain cyanoacrylate as an adhesive for intraoral wound closure and also to explore its hemostatic and antibacterial effects. Isoamyl-2-cyanoacrylate (AMCRYLATE was used as the adhesive in the study. In conclusion isoamyl cyanoacrylate can be used for intraoral wound closure, as an alternative to sutures for gluing the mucoperiosteum to bone, for example, after impaction removal, periapical surgeries, and cleft repair. Its hemostatic and antibacterial activity has to be further evaluated.

  7. Regular Versus Releasable Sutures in Surgery for Primary Congenital Glaucoma.

    Science.gov (United States)

    Bayoumi, Nader H

    2017-09-01

    To compare releasable and regular sutures in combined angle and filtering surgery for primary congenital glaucoma. A prospective study was conducted on 39 eyes (26 right eyes) of 39 children (20 boys; 19 girls) who had primary congenital glaucoma treated with combined trabeculotomy-trabeculectomy with mitomycin C and scleral flap closure with regular or releasable sutures. Follow-up was 24 months. Success rates (defined as an intraocular pressure [IOP] suture group (20 eyes) and 5.3 ± 2.8 months (range: 1 to 13 months; median: 5 months) in the releasable suture group (19 eyes). The initial glaucoma surgery was successful in 13 (65%) and 13 (68.4%) eyes in the regular suture and releasable suture groups, respectively. The mean IOP was 17.4 ± 7.3 and 16.0 ± 5.4 mm Hg (P = .84) preoperatively and 8.0 ± 9.7 and 5.8 ± 3.6 mm Hg (P = .40) at the end of follow-up in the regular suture and releasable suture groups, respectively. There was no statistically significant difference in the clinical parameters between the two groups. Complications included rhegmatogenous retinal detachment, cataract, and superior lens subluxation, with each complication developing in one eye. Releasable sutures were not more advantageous than regular sutures in combined trabeculotomy-trabeculectomy with mitomycin C surgery for primary congenital glaucoma. [J Pediatr Ophthalmol Strabismus. 2017;54(5):295-301.]. Copyright 2017, SLACK Incorporated.

  8. Skull mechanics and the evolutionary patterns of the otic notch closure in capitosaurs (Amphibia: Temnospondyli).

    Science.gov (United States)

    Fortuny, Josep; Marcé-Nogué, Jordi; Gil, Lluis; Galobart, Angel

    2012-07-01

    Capitosaurs were among the largest amphibians that have ever lived. Their members displayed an amphibious lifestyle. We provide new information on functional morphology data, using finite element analysis (FEA) which has palaeoecological implications for the group. Our analyses included 17 taxa using (2D) plate models to test four loading cases (bilateral, unilateral and lateral bitings and skull raising system simulation). Our results demonstrates that, when feeding, capitosaurs concentrated the stress at the circumorbital region of the capitosaur skull and cranial sutures probably played a key role in dissipating and absorbing the stress generated during biting. Basal members (as Wetlugasaurus) were probably less specialized forms, while during Middle- and Late Triassic the group radiated into different ecomorphotypes with closed otic notch forms (as Cyclotosaurus) resulting in the strongest skulls during biting. Previous interpretations discussed a trend from an open to closed otic notch associated with lateral repositioning of the tabular horns, but the analysis of the skull-raising system reveals that taxa exhibiting posteriorly directed tabular horns display similar results during skull raising to those of closed otic notch taxa. Our results suggest that various constraints besides otic notch morphology, such as the elongation of the tabular horns, snout length, skull width and position, and size of the orbits affect the function of the skull. On the light of our results, capitosaur skull showed a trend to reduce the stresses and deformation during biting. Capitosaurs could be considered crocodilian analogues as they were top-level predators in fluvial and brackish Triassic ecosystems. Copyright © 2012 Wiley Periodicals, Inc.

  9. Study of two techniques for midline laparotomy fascial wound closure.

    Science.gov (United States)

    Gurjar, Vipul; Halvadia, B M; Bharaney, R P; Ajwani, Vicky; Shah, S M; Rai, Samir; Trivedi, Mitesh

    2014-04-01

    To study the results of two techniques, simple interrupted closure and continuous with intermittent Aberdeen knot technique for midline laparotomy fascial wound closure. A random selection of 200 midline laparotomy cases was done. In one group (group A) of 100 cases, midline fascial wound closure was done with continuous sutures with intermittent Aberdeen knot technique using Prolene No. 1 suture material. In the other group (group B) of 100 cases, closure was done with the technique of simple interrupted sutures with Prolene No.1 suture material. Comparison of both the techniques regarding preoperative status and postoperative complication such as incisional hernia, wound dehiscence, suture sinus formation, stitch granuloma, and chronic wound pain was done according to clinical examination and recorded in the pro forma prepared. In group A, postoperative complications were incisional hernia 3 %, wound dehiscence 4 %, and suture sinus formation 1 %. In group B, postoperative complication were incisional hernia 5 %, wound dehiscence 4 %, and suture sinus formation 1 %. All these complications were statistically insignificant, in both group comparisons. While the complication such as stitch granuloma 3 %, chronic wound pain 3 %, and wound infection 4 % in group A was significantly less than in group B where the complication of stitch granuloma was 12 %, chronic wound pain 13 %, and wound infection 13 % (P value 0.03, P value 0.018, and P value 0.048, respectively). Both the techniques, simple interrupted suture closure and continuous with intermittent Aberdeen knot closure for midline laparotomy fascial wounds, show a similar rate of postoperative complication such as incisional hernia, wound dehiscence, and suture sinus formation. But the continuous suturing with intermittent Aberdeen knot technique is a better option to prevent complications such as stitch granuloma, chronic wound pain, and wound infection, which are higher in the simple interrupted

  10. Ex vivo biomechanical comparison of barbed suture and standard polypropylene suture for acute tendon laceration in a canine model.

    Science.gov (United States)

    Duffy, D J; Main, R P; Moore, G E; Breur, G J; Millard, R P

    2015-01-01

    Evaluate performance and resistance to gap formation of a non-absorbable, barbed, monofilament suture, in comparison with a non-absorbable, smooth, monofilament polypropylene suture, in two different suture patterns: three-loop pulley (3LP) and modified Bunnell-Mayer (BM). Seventy-two medium-sized cadaveric superficial digital flexor muscle tendon units. After manual transection and suture repair, individual specimens were placed in an electromechanical tensile testing machine and tested to monotonic failure using tensile ramp loading. Video data acquisition allowed evaluation of failure mode and quantification of gap formation. Incidence of gap formation between tendon ends was significantly greater in tenorrhaphies repaired with barbed suture compared to those repaired with smooth polypropylene. Use of a 3LP suture pattern caused significantly less gapping between tendon ends when compared to the BM pattern. Smooth polypropylene suture was consistently superior in load performance than a unidirectional barbed suture. The 3LP pattern was more resistant than a BM pattern at preventing gap formation. Smooth polypropylene should be recommended over barbed unidirectional suture for use in canine tendinous repair to provide increased resistance to gap formation. The 3LP is superior to the BM suture pattern, requiring significantly more force to cause tenorrhaphy gap formation and failure, which may translate to increased accrual of repair site strength and tendinous healing in clinical situations.

  11. Effect of the application of a bundle of three measures (intraperitoneal lavage with antibiotic solution, fascial closure with Triclosan-coated sutures and Mupirocin ointment application on the skin staples) on the surgical site infection after elective laparoscopic colorectal cancer surgery.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Llavero, Carolina; Morales, Vicente; Gamallo, Carlos

    2018-01-18

    Surgical site infection (SSI) prevention bundles include the simultaneous use of different measures, which individually have demonstrated an effect on prevention of SSI. The implementation of bundles can yield superior results to the implementation of individual measures. The aim of this study was to address the effect of the application of a bundle including intraperitoneal lavage with antibiotic solution, fascial closure with Triclosan-coated sutures and Mupirocin ointment application on the skin staples, on the surgical site infection after elective laparoscopic colorectal cancer surgery. A prospective, randomized study was performed, including patients with diagnosis of colorectal neoplasms and plans to undergo an elective laparoscopic surgery. The patients were randomized into two groups: those patients following standard bundles (Group 1) and those ones following the experimental bundle with three additional measures, added to the standard bundle. Incisional and organ space SSI were investigated. The study was assessor-blinded. A total of 198 patients were included in the study, 99 in each group. The incisional SSI rate was 16% in Group 1 and 2% in Group 2 [p = 0.007; RR = 5.6; CI 95% (1.4-17.8)]. The organ-space SSI rate was 4% in Group 1 and 0% in Group 2 [p = 0.039; RR = 1.7; CI 95% (1.1-11.6)]. Median hospital stay was 5.5 days in Group 1 and 4 days in Group 2 (p = 0.028). The addition of intraperitoneal lavage with antibiotic solution, fascial closure with Triclosan-coated sutures and Mupirocin ointment application on the skin staples, to a standard bundle of SSI prevention, reduces the incisional and organ-space SSI and consequently the hospital stay, after elective laparoscopic colorectal cancer surgery (ClinicalTrials.gov Identifier: NCT03081962).

  12. Absence of endochondral ossification and craniosynostosis in posterior frontal cranial sutures of Axin2(-/- mice.

    Directory of Open Access Journals (Sweden)

    Björn Behr

    Full Text Available During the first month of life, the murine posterior-frontal suture (PF of the cranial vault closes through endochondral ossification, while other sutures remain patent. These processes are tightly regulated by canonical Wnt signaling. Low levels of active canonical Wnt signaling enable endochondral ossification and therefore PF-suture closure, whereas constitutive activation of canonical Wnt causes PF-suture patency. We therefore sought to test this concept with a knockout mouse model. PF-sutures of Axin2(-/- mice, which resemble a state of constantly activated canonical Wnt signaling, were investigated during the physiological time course of PF-suture closure and compared in detail with wild type littermates. Histological analysis revealed that the architecture in Axin2(-/- PF-sutures was significantly altered in comparison to wild type. The distance between the endocranial layers was dramatically increased and suture closure was significantly delayed. Moreover, physiological endochondral ossification did not occur, rather an ectopic cartilage appeared between the endocranial and ectocranial bone layers at P7 which eventually involutes at P13. Quantitative PCR analysis showed the lack of Col10α1 upregulation in Axin2(-/- PF-suture. Immunohistochemistry and gene expression analysis also revealed high levels of type II collagen as compared to type I collagen and absence of Mmp-9 in the cartilage of Axin2(-/- PF-suture. Moreover, TUNEL staining showed a high percentage of apoptotic chondrocytes in Axin2(-/- PF-sutures at P9 and P11 as compared to wild type. These data indicated that Axin2(-/- PF-sutures lack physiological endochondral ossification, contain ectopic cartilage and display delayed suture closure.

  13. Astigmatism induced by intrastromal corneal suture after small incision phacoemulsification.

    Science.gov (United States)

    Chipont-Benabent, E; Artola Roig, A; Pérez-Santonja, J J; Guisbert Medel, M; Alió Sanz, J L

    1998-04-01

    To evaluate the course of astigmatic evolution and complications after clear corneal incisions using an intrastromal corneal suture. Instituto Oftalmologico de Alicante, University of Alicante, Spain. Eighty eyes of 62 patients had endocapsular phacoemulsification. A foldable intraocular lens was implanted through a 4.0 mm clear corneal incision. A 10-0 nylon intrastromal corneal suture was used in all eyes. Change sin corneal astigmatism were calculated by vector analysis; follow-up was 6 months. Early and late suture-related complications were also evaluated. Mean induced cylinder was 1.25 diopters (D) +/- 1.24 (SD) with the wound 1 day postoperatively and 0.19 +/- 0.81 D against the wound at 6 months. There were no incision- or suture-related complications postoperatively. Use of the intrastromal corneal suture led to astigmatically neutral closure of multiplanar corneal incisions.

  14. Influence of suturing on wound healing.

    Science.gov (United States)

    Burkhardt, Rino; Lang, Niklaus P

    2015-06-01

    The present article describes the significance of suturing and appropriate suture materials in current periodontal and implant surgery. Synthetic, nonresorbable, monofilament threads appear to be advantageous. The physical and biological properties of such threads remain unchanged with use and, when used in small diameters (i.e. with lower breaking resistance), seem to promote passive wound closure. Wound healing at hard, nonshedding surfaces is conceptually a more complex process than is wound healing in most other sites of the oral cavity. Firm adaptation and stabilization of the flaps by optimal suturing ensures adhesion of the delicate fibrin clot to the nonshedding surface. The early formation and mechanical stability of the blood clot between the mucosal or mucoperiosteal flap and the wound bed are of paramount importance and hence suturing techniques must be considered as a key prerequisite to ensure optimal surgical outcomes. With the sophisticated surgical procedures now applied, there is a greater need for knowledge with regard to the various types of suturing techniques and materials available in order to achieve the above-mentioned goals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Surgical suture assembled with polymeric drug-delivery sheet for sustained, local pain relief.

    Science.gov (United States)

    Lee, Ji Eun; Park, Subin; Park, Min; Kim, Myung Hun; Park, Chun Gwon; Lee, Seung Ho; Choi, Sung Yoon; Kim, Byung Hwi; Park, Hyo Jin; Park, Ji-Ho; Heo, Chan Yeong; Choy, Young Bin

    2013-09-01

    Surgical suture is a strand of biocompatible material designed for wound closure, and therefore can be a medical device potentially suitable for local drug delivery to treat pain at the surgical site. However, the preparation methods previously introduced for drug-delivery sutures adversely influenced the mechanical strength of the suture itself - strength that is essential for successful wound closure. Thus, it is not easy to control drug delivery with sutures, and the drug-delivery surgical sutures available for clinical use are now limited to anti-infection roles. Here, we demonstrate a surgical suture enabled to provide controlled delivery of a pain-relief drug and, more importantly, we demonstrate how it can be fabricated to maintain the mechanical strength of the suture itself. For this purpose, we separately prepare a drug-delivery sheet composed of a biocompatible polymer and a pain-relief drug, which is then physically assembled with a type of surgical suture that is already in clinical use. In this way, the drug release profiles can be tailored for the period of therapeutic need by modifying only the drug-loaded polymer sheet without adversely influencing the mechanical strength of the suture. The drug-delivery sutures in this work can effectively relieve the pain at the surgical site in a sustained manner during the period of wound healing, while showing biocompatibility and mechanical properties comparable to those of the original surgical suture in clinical use. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Atraumatic intracutaneous skin closure with self-made fishing line ...

    African Journals Online (AJOL)

    Objective: The aim of this study was to prove, whether the intracutaneous skin closure with self made fishing line suture is equivalent to commercial sutures. Design: It was a randomised blinded animal study. Setting: The study was performed in December 2002 at the Muhimbili University College of Health Sciences in ...

  17. Techniques and materials for skin closure in caesarean section

    DEFF Research Database (Denmark)

    Mackeen, A Dhanya; Berghella, Vincenzo; Larsen, Mie-Louise

    2012-01-01

    Caesarean section is a common operation with no agreed upon standard regarding certain operative techniques or materials to use. With regard to skin closure, the skin incision can be re-approximated by a subcuticular suture immediately below the skin layer, by an interrupted suture, or by staples...

  18. Skin closure after groin hernia repair in children: a comparative ...

    African Journals Online (AJOL)

    Patients and Methods: Three suture materials (chromic catgut 3/0, silk 3/0 and nylon 3/0) and two skin closure techniques (transcutaneous interrupted mattress and subcuticular continuous running sutures) were compared in a randomized partially blinded fashion using a groin skin crease incision. The resulting scars were ...

  19. Cleft lip repair with subcuticular closure at National Orthopaedic ...

    African Journals Online (AJOL)

    Nigerian Journal of Plastic Surgery ... This five year study was undertaken to verify if subcuticular closure in unilateral cleft lip surgery reduced the burden of care. ... Result: Patients with skin suture had 124 surgical sessions and a mean of 7.11 days after surgery before discharge; and those with subcuticular sutures spent a ...

  20. Hypersensitivity to Suture Anchors

    OpenAIRE

    Masafumi Goto; Masafumi Gotoh; Yasuhiro Mitsui; Ryo Tanesue; Takahiro Okawa; Fujio Higuchi; Naoto Shiba

    2013-01-01

    Hypersensitivity to suture anchor is extremely rare. Herein, we present a case in which hypersensitivity to suture anchor was strongly suspected. The right rotator cuff of a 50-year-old woman was repaired with a metal suture anchor. Three weeks after the surgery, she developed erythema around her face, trunk, and hands, accompanied by itching. Infection was unlikely because no abnormalities were detected by blood testing or by medical examination. Suspicious of a metallic allergy, a dermatolo...

  1. Adhesive strip wound closure after thyroidectomy/parathyroidectomy: a prospective, randomized controlled trial.

    LENUS (Irish Health Repository)

    O'Leary, D Peter

    2013-03-01

    Conventional collar incision closure in thyroid and parathyroid surgery involves the insertion of an epidermal layer of subcutaneous absorbable sutures that are reinforced by a deep layer of sutures. Adhesive strips offer an alternative method to close the epidermal layer. The aim of this study was to compare adhesive strip closure with absorbable sutures for collar incisions in a prospective, single-blinded, randomized controlled trial.

  2. Sutures and suture anchors--update 2006.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Coons, David A; Boothby, Michael H

    2006-10-01

    To evaluate recently introduced sutures and suture anchors for single pull load to failure strength and failure mode. Suture anchors were tested in fresh porcine metaphyseal cortex and cancellous troughs with the use of an established protocol. An Instron machine applied tensile loads parallel to the axis of insertion at a rate of 12.5 mm/sec until failure, and mean anchor failure strengths were calculated. The mode of failure (anchor pull-out, suture eyelet cut-out, or suture failure) was recorded. Anchors tested included the BioRaptor 2.9, BioZip, Super Revo, Impact, Allograft cortical anchor, SpiraLok, Herculon, AxyaLoop titanium anchors 3, 5, and 6.5 mm, AxyaLoop bioabsorbable anchors 3, 5, and 6.5, ParaFix titanium anchors 3, 5, and 6.5, ParaSorb BioAnchors 3, 5.5, and 6.5, and Bio-Corkscrew FT. Sutures were also tested through an established protocol for load to failure. Sutures tested consisted of Orthocord, Ultrabraid (White and CoBraid), ForceFiber, Hi-Fi, MagnumWire, and Maxbraid Polyethylene Plus. Mean failure loads were as follows: BioRaptor 238 N, BioZip 366 N, double-loaded Super Revo 486 N, triple-loaded Super Revo 362 N, Impact 202 N, Allograft cortical anchor 240 N, SpiraLok 289 N, Herculon 819 N, AxyaLoop titanium anchors 3.0 (335 N), 5.0 (485 N), and 6.5 mm (465 N), AxyaLoop bioabsorbable anchors 3 (143 N), 5 (395 N), and 6.5 (369 N), ParaFix titanium anchors 3 (335 N), 5 (485 N), and 6.5 (465 N), ParaSorb BioAnchors 3 (143 N), 5.5 (395 N), and 6.5 (369 N), and Bio-Corkscrew FT (260 N). The sutures all broke at the mid point of their tested strands away from the grips. Mean suture strength for No. 2 Orthocord was 92 N; for No. 2 Ultrabraid CoBraid and White, strengths were 265 N and 280 N, respectively; strength for No. 2 Force Fiber was 289 N, for No. 2 Hi-Fi 250 N, for No. 2 MagnumWire 303 N, and for No. 2 Maxbraid Polyethylene Plus 256 N. Newer suture products showed significant improvements in load to failure values when compared with braided

  3. A rare case of persistent metopic suture in an elderly individual: Incidental autopsy finding with clinical implications

    Directory of Open Access Journals (Sweden)

    S Vikram

    2014-01-01

    Full Text Available Metopic suture is a dense fibrous joint extending from the nasion to the bregma. Normally, closure of this suture takes place between 1-8 years of age. Failure of this closure beyond 8 years leads to persistent metopic suture. A rare case of persistent metopic suture in a 60-year-old male is documented, who committed suicide by alleged consumption of organophosphorous compound at District Govt. Wenlock Hospital, Mangalore, Karnataka, India. Metopic suture may mimic skull fracture and may mislead an inexperienced forensic expert. Neurosurgeon should also be aware of this anatomical variation while performing frontal craniotomy, as the persistent metopic suture may mimic vertical fracture of the skull. Hence, in this case report, the clinical and medico-legal implications of the persistent metopic sutures have been discussed.

  4. [Hermetic sealing of the cataract incision with intracorneal mattress sutures].

    Science.gov (United States)

    Alekseev, B N; Voronin, G V

    1998-01-01

    Main factors of hermetic closure of an operative wound in cataract extraction with intracapsular implantation of intraocular lens are discussed. A new method for closure of operation wound in this operation is proposed. Opposition intracorneal mattress sutures are made over the incision plane. Their principal feature is that the thread is not thrown over the external edge of corneal incision, as in traditional non-opposition sutures, and during pulling and suture the thread does not deform the external surface of the cornea in the central zone and hence, causes no postoperative corneal astigmatism. A method combining opposition and interrupted non-opposition sutures is proposed, and various combinations of these sutures are compared. Forty-five patients (45 eyes) were operated on using the proposed technique. Opposition sutures made in accordance with the methods proposed by the authors do not cause high postoperative corneal astigmatism, or it approximates the normal values of corneal astigmatism. A special marker is proposed for preliminary marking of sites for nonperforating incisions on the cornea and the site of cataract incision.

  5. Hydrostatic comparison of nonpenetrating titanium clips versus conventional suture for repair of spinal durotomies.

    Science.gov (United States)

    Faulkner, Nathan D; Finn, Michael A; Anderson, Paul A

    2012-04-20

    Biomechanics. To compare the hydrostatic strength of suture and nonpenetrating titanium clip repairs of standard spinal durotomies. Dural tears are a frequent complication of spine surgery and can be associated with significant morbidity. Primary repair of durotomies with suture typically is attempted, but a true watertight closure can be difficult to obtain because of leakage through suture tracts. Nonpenetrating titanium clips have been developed for vascular anastomoses and provide a close apposition of the tissues without the creation of a suture tract. Twenty-four calf spines were prepared with laminectomies and the spinal cord was evacuated leaving an intact dura. After Foley catheters were inserted from each end and inflated adjacent to a planned dural defect, the basal flow rate was measured and a 1-cm longitudinal durotomy was made with a scalpel. Eight repairs were performed for each material, which included monofilament suture, braided suture, and nonpenetrating titanium clips. The flow rate at 30, 60, and 90 cm of water and the time needed for each closure were measured. There was no statistically significant difference in the baseline leak rate for all 3 groups. There was no difference in the leakage rate of durotomies repaired with clips and intact specimens at any pressure. Monofilament and braided suture repairs allowed significantly more leakage than both intact and clip-repaired specimens at all pressures. The difference in leak rate increased as the pressure increased. Closing the durotomy with clips took less than half the time of closure with suture. Nonpenetrating titanium clips provide a durotomy closure with immediate hydrostatic strength similar to intact dura whereas suture repair with either suture was significantly less robust. The use of titanium clips was more rapid than that of suture repair.

  6. Cardiac Device Implant Skin Closure with a Novel Adjustable, Coaptive Tape-Based Device.

    Science.gov (United States)

    Lalani, Gautam G; Schricker, Amir A; Salcedo, Jonathan; Hebsur, Shrinivas; Hsu, Jonathan; Feld, Gregory; Birgersdotter-Green, Ulrika

    2016-10-01

    The purpose of this study was to compare a unique zip-type adjustable coaptive tape-based skin closure device to traditional subcuticular sutures in three domains: time, cosmesis, and wound closure-related outcomes in cardiac implantable electronic device (CIED) procedures. A total of 40 patients were enrolled in a prospective randomized controlled trial to assess time to wound closure, as well as cosmesis and wound closure-related outcomes. The adjustable coaptive tape-based skin closure device had shorter overall closure time (78 ± 6.6 seconds vs 216 ± 21.5 seconds; P < 0.001) and mean closure time per centimeter (18.0 ± 2.0 s/cm vs 50.1 ± 6.7 s/cm; P < 0.001) versus sutures, with less intersurgeon and interpatient variability with the use of adjustable coaptive device versus sutures (P < 0.001). There was no difference between groups in postoperative pain or scar cosmesis during the follow-up period. Neither group had any closure-related adverse events. The adjustable coaptive tape-based skin closure device demonstrated shorter closure times with less variability when compared to sutures. It is a safe and acceptable alternative to sutures for skin closure following CIED implantation. © 2016 Wiley Periodicals, Inc.

  7. Enhancement of wound closure by modifying dual release patterns of stromal-derived cell factor-1 and a macrophage recruitment agent from gelatin hydrogels.

    Science.gov (United States)

    Kim, Yang-Hee; Tabata, Yasuhiko

    2017-11-01

    The objective of the present study is to evaluate the effects of the release patterns of stromal derived factor (SDF)-1 and sphingosine-1 phosphate agonist (SEW2871), used as MSC and macrophage recruitment agents, on the wound closure of diabetic mouse skin defects. To achieve different release patterns, hydrogels were prepared using two types of gelatin with isoelectric points (IEP) of 5 and 9, into which SDF-1 and SEW2871 were then incorporated in various combinations. When the hydrogels incorporating SDF-1 and SEW2871 were applied into wound defects of diabetic mice, the number of MSCs and macrophages recruited to the defects and the levels of pro- and anti- inflammatory cytokines were found to be dependent on the release profiles of SDF-1 and SEW2871. Of particular interest was the case of a rapid release of SDF-1 combined with a controlled release of SEW2871. This resulted in a higher number of M2 macrophages and gene expression levels of anti-inflammatory cytokines 3 days after implantation and faster wound closure than when pairing the controlled release of SDF-1 with a rapid release of SEW2871. Therefore, the present study demonstrates that different release patterns of SDF-1 and SEW2871 can enhance the in vivo recruitment of MSCs and macrophages, and can promote skin wound closure through the modulation of inflammation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. In utero Plastic Surgery in Zurich: Successful Use of Distally Pedicled Random Pattern Transposition Flaps for Definitive Skin Closure during Open Fetal Spina Bifida Repair.

    Science.gov (United States)

    Meuli, Martin; Meuli-Simmen, Claudia; Mazzone, Luca; Tharakan, Sasha J; Zimmermann, Roland; Ochsenbein, Nicole; Moehrlen, Ueli

    2017-12-20

    One of the intraoperative challenges of fetal spina bifida repair is skin closure when there is an extended skin defect. Thus, we examined whether distally pedicled random pattern transposition flaps (TFs) are a valid option to overcome this problem. All patients undergoing in utero repair of spina bifida with application of a TF for back skin closure were analyzed focusing on intraoperative flap characteristics and postoperative flap performance. In 30 (70%) of the 43 fetuses a primary skin closure was achieved, in 5 (12%) a skin substitute was used, and in 8 (18%) a TF was applied. Flap raising and insertion was uneventful and perfusion was sufficient in all 8 fetuses (100%). In 3 fetuses (37%) the donor sites were closed primarily, and in 5 (63%) a skin substitute was used for coverage. At birth, 7 flaps were viable and provided robust skin coverage over the center of the former lesion. Complications included a small skin defect with CSF leakage in 1 patient (13%). During open fetal spina bifida repair, TFs can be safely and efficaciously used to obtain solid and durable skin coverage over lesions too large to allow conventional primary skin closure. © 2017 S. Karger AG, Basel.

  9. Bioinspired polymeric surface patterns for medical applications.

    Science.gov (United States)

    Kroner, Elmar; Kaiser, Jessica S; Fischer, Sarah C L; Arzt, Eduard

    2012-01-01

    A powerful principle in nature is the presence of surface patterns to improve specific characteristics or to enable completely new functions. Here, we present two case studies where bioinspired surface patterns based on the adhesive system of geckos may be applied for biomedical applications: residue-free adhesion to skin and gecko-inspired suture threads for knot-free wound closure. Gecko-inspired skin adhesives were fabricated by soft lithography of polydimethylsiloxane with successive inking and dipping steps. Their adhesion was measured using a home built adhesion tester designed for patterned surfaces. Preliminary lap shear tests on the back of a human hand were also performed. Commercial suture threads from different materials were patterned in the group of A. del Campo at the Max-Planck-Institute for Polymer Research (Mainz, Germany) using oxygen plasma. The treated threads were pulled through artificial skin in both directions measuring the peak force and the pull through force. Unpatterned reference samples of the skin adhesive did not stick to human skin, while the patterned samples all showed notable adhesion up to 1.2 Newton for a sample size of approximately 3 cm². First results with the patterned suture threads indicated that the surface patterning of the thread has only a minor effect on the pull-through forces. To achieve knot-free sewing the surface geometry of the suture threads needs to be optimized and more realistic testing procedures, e.g. testing on human skin, are necessary.

  10. A randomized 'N-of-1' single blinded clinical trial of barbed dermal sutures vs. smooth sutures in elective plastic surgery shows differences in scar appearance two-years post-operatively.

    Science.gov (United States)

    Koide, S; Smoll, N R; Liew, J; Smith, K; Rizzitelli, A; Findlay, M W; Hunter-Smith, D J

    2015-07-01

    Barbed sutures have unidirectional circumferential shallow barbs, which distribute tension throughout the wound and close wound securely without the need to tie knots. We compare two different methods of wound closure in elective plastic surgical cases: barbed 3/0 V-Loc™180 suture and smooth 3/0 Maxon™ sutures, both polyglyconate monofilament synthetic absorbable sutures. We assessed the aesthetic long-term results with a minimum two year follow up. This is a prospective, randomized controlled study with internal control. A single surgeon performed all cases. Patients who underwent elective operations that involved long wound closure were enrolled in the study. Each patient acted as their own internal control with half their wound being sutured with 3/0 V-Loc™180 barbed suture and the other half with smooth 3/0 Maxon™ deep dermal sutures and then a subcuticular skin closure. In both groups, the superficial fascial system was closed with 1 Vicryl interrupted sutures on both sides. Long-term cosmesis was evaluated using the modified Hollander cosmesis score by review of standardized postoperative photographs by 9 blinded plastic surgeons and specialist registrars. The study reports on 33 female patients. The time taken for wound closure was significantly reduced using the barbed suture (p suture (p = 0.0075). Barbed sutures closure of long wounds is faster and produces a better long-term aesthetic outcome than smooth sutures. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.

    Science.gov (United States)

    Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro

    2015-12-01

    The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial

  12. Hypersensitivity to Suture Anchors

    Directory of Open Access Journals (Sweden)

    Masafumi Goto

    2013-01-01

    Full Text Available Hypersensitivity to suture anchor is extremely rare. Herein, we present a case in which hypersensitivity to suture anchor was strongly suspected. The right rotator cuff of a 50-year-old woman was repaired with a metal suture anchor. Three weeks after the surgery, she developed erythema around her face, trunk, and hands, accompanied by itching. Infection was unlikely because no abnormalities were detected by blood testing or by medical examination. Suspicious of a metallic allergy, a dermatologist performed a patch testing 6 months after the first surgery. The patient had negative reactions to tests for titanium, aluminum, and vanadium, which were the principal components of the suture anchor. The anchor was removed 7 months after the first surgery, and the erythema disappeared immediately. When allergic symptoms occur and persist after the use of a metal anchor, removal should be considered as a treatment option even if the patch test result is negative.

  13. Bacterial adhesion to suture material in a contaminated wound model: Comparison of monofilament, braided, and barbed sutures.

    Science.gov (United States)

    Dhom, Jonas; Bloes, Dominik A; Peschel, Andreas; Hofmann, Ulf K

    2017-04-01

    Contaminated suture material plays an important role in the physiopathology of surgical site infections. Recently, suture material has been developed characterized by barbs projecting from a monofilament base. Claimed advantages for barbed sutures are a shortened wound closure time and reduced maximum wound tension. It has also been suggested that these sutures would be advantageous microbiologically. The aim of this study was to test the microbiological characteristics of the barbed Quill in comparison to the monofilament Ethilon II and the braided sutures Vicryl and triclosan-coated Vicryl Plus. In our study, sutures were cultivated on color-change agar with Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, Escherichia coli, and Pseudomonas aeruginosa and the halo size was measured. In a second study arm with longer cultivation bacterial growth was followed by antibiotic treatment. Ethilon II and Quill showed good comparable results, whereas large halos were found around Vicryl. Vicryl Plus results depended on triclosan sensitivity. After longer bacterial cultivation and antibiotic treatment, halos were up to 3.6 times smaller on Quill than on Vicryl (p sutures can be recommended in aseptic surgery, but should only be used carefully in septic surgery. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:925-933, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. MonoMax Suture: A New Long-Term Absorbable Monofilament Suture Made from Poly-4-Hydroxybutyrate

    Directory of Open Access Journals (Sweden)

    Erich K. Odermatt

    2012-01-01

    Full Text Available A long-term absorbable monofilament suture was developed using poly-4-hydroxybutyrate (P4HB made from a biosynthetically produced homopolymer of the natural metabolite 4-hydroxybutyrate. The suture, called MonoMax, has prolonged strength retention. At 12 weeks, a size 3-0 MonoMax suture retains approximately 50% of its initial tensile strength in vivo and is substantially degraded in one year with minimal tissue reaction. In contrast, PDS II monofilament suture (Ethicon, Inc., Somerville, NJ has no residual strength in vivo after 12 weeks. In vivo, the MonoMax suture is hydrolyzed primarily by bulk hydrolysis, and is then degraded via the Krebs cycle. MonoMax is substantially more compliant than other monofilament sutures, and incorporates an element of elasticity. Its tensile modulus of 0.48 GPa is approximately one-third of the value of the PDS II fiber providing an exceptionally flexible and pliable fiber with excellent knot strength and security. These features are further enhanced by the fiber's elasticity, which also improves knot security and may help prevent wound dehiscence. Because of its performance advantages, this suture may find clinical utility in applications where prolonged strength retention, and greater flexibility are required, particularly in procedures like abdominal wall closure where wound dehiscence is still a significant post-surgical complication.

  15. A study of the efficacy of antibacterial sutures for surgical site infection: a retrospective controlled trial.

    Science.gov (United States)

    Hoshino, Seiichiro; Yoshida, Yoichiro; Tanimura, Syu; Yamauchi, Yasushi; Noritomi, Tomoaki; Yamashita, Yuichi

    2013-01-01

    To reduce bacterial adherence to surgical sutures, triclosan-coated polyglactin 910 suture materials with antiseptic activity were developed. The aim of this study was to evaluate whether the incidence of surgical site infections can be reduced when triclosan-coated sutures are used. Until December 2009, we used conventional polyglactin 910 sutures (VICRYL, Ethicon) for the closure of the fascia in digestive tract surgery. Therefore, for the control group we retrospectively collected surveillance data for 1.5 years. In the control group, 611 patients underwent digestive tract surgery with VICRYL sutures. Beginning in July 2010, we used triclosan-coated polyglactin 910 sutures (VICRYL Plus, Ethicon, Tokyo, Japan) for the closure of the fascia in all digestive surgeries. So, we collected data for the study group from July 2010 until June 2011. In the study group, 467 patients underwent digestive tract surgery with triclosan-coated VICRYL Plus sutures. In the control group, 75 patients (12.2%) developed wound infections. In the study group, 31 patients (6.6%) developed wound infections, which was significantly lower. Emergency cases; laparoscopic cases, including some cholecystectomy and colectomy cases; American Society of Anesthesiologists classification; the use of immunosuppressive therapy; colostomy cases; wound classification; and suture material were identified as the risk factors for wound infections. In both groups, as the wound classification worsened, the wound infection rate increased. Triclosan-coated polyglactin 910 antimicrobial sutures lead to a significant decrease in the incidence of surgical site infections, especially in clean/contaminated cases.

  16. Metopic suture and RUNX2, a key transcription factor in osseous morphogenesis with possible important implications for human brain evolution.

    Science.gov (United States)

    Magherini, Stefano; Fiore, Maria Giulia; Chiarelli, Brunetto; Serrao, Antonio; Paternostro, Ferdinando; Morucci, Gabriele; Branca, Jacopo J V; Ruggiero, Marco; Pacini, Stefania

    2015-01-01

    Overall, the comparative data available on the timing of metopic suture closure in present-day and fossil members of human lineage, as well as great apes, seem to indicate that human brain evolution occurred within a complex network of fetopelvic constraints, which required modification of frontal neurocranial ossification patterns, involving delayed fusion of the metopic suture. It is very interesting that the recent sequencing of the Neanderthal genome has revealed signs of positive selection in the modern human variant of the RUNX2 gene, which is known to affect metopic suture fusion in addition to being essential for osteoblast development and proper bone formation. It is possible that an evolutionary change in RUNX2, affecting aspects of the morphology of the upper body and cranium, was of importance in the origin of modern humans. Thus, to contribute to a better understanding of the molecular evolution of this gene probably implicated in human evolution, we performed a comparative bioinformatic analysis of the coding sequences of RUNX2 in Homo sapiens and other non-human Primates. We found amino-acid sequence differences between RUNX2 protein isoforms of Homo sapiens and the other Primates examined, that might have important implications for the timing of metopic suture closure. Further studies are needed to clear the potential distinct developmental roles of different species-specific RUNX2 N-terminal isoforms. Meantime, our bioinformatic analysis, regarding expression of the RUNX2 gene in Homo sapiens and other non-human Primates, has provided a contribution to this important issue of human evolution.

  17. Influence of Embedded Fibers and an Epithelium Layer on the Glottal Closure Pattern in a Physical Vocal Fold Model

    Science.gov (United States)

    Xuan, Yue; Zhang, Zhaoyan

    2014-01-01

    Purpose: The purpose of this study was to explore the possible structural and material property features that may facilitate complete glottal closure in an otherwise isotropic physical vocal fold model. Method: Seven vocal fold models with different structural features were used in this study. An isotropic model was used as the baseline model, and…

  18. Triclosan sutures for surgical site infection in colorectal cancer.

    Science.gov (United States)

    Yamashita, Kanefumi; Takeno, Shinsuke; Hoshino, Seiichiro; Shiwaku, Hironari; Aisu, Naoya; Yoshida, Yoichiro; Tanimura, Syu; Yamashita, Yuichi

    2016-11-01

    Among all procedures, surgical site infections (SSIs) in colorectal surgery continue to have the highest rate, accounting for 5%-45%. To prevent the bacterial colonization of suture material, which disables local mechanisms of wound decontamination, triclosan-coated sutures were developed. We assessed the effectiveness of triclosan-coated sutures used for skin closure on the rate of SSIs in colorectal cancer surgery. Until August 2012, we used conventional methods for skin closure in colorectal cancer surgery at the Department of Gastroenterological Surgery, Fukuoka University Faculty of Medicine. Therefore, for the control group, we retrospectively collected surveillance data over a 1.5-y period. From September 2012, we began using triclosan-coated polydioxanone antimicrobial sutures (PDS plus) for skin and fascia closure. Hence, we collected data for the study group from September 2012 to October 2013. Differences in baseline characteristics and selection bias were adjusted using the propensity score-matching method. A total of 399 patients who underwent colorectal surgery were included in this study. There were 214 patients in the control group and 185 patients in the study group. Baseline patient characteristics were similar between the propensity score-matched groups. The incidence of SSIs was less in the study group. Multivariate logistic regression analysis showed that the site of the procedure, laparoscopic surgery, and using triclosan-coated sutures remained the independent predictors of SSIs. The use of triclosan-coated sutures was advantageous for decreasing the risk of SSIs after colorectal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Application of static fatigue testing to the behavior of absorbable sutures.

    Science.gov (United States)

    Prati, J L; Kim, D H; Matthewson, M J

    2017-10-01

    Absorbable sutures, since their conception, have become the dominant method for surgical wound closure and are constantly being improved. However, despite their years of service, not all aspects of their performance are fully understood. In particular, suture absorption is usually characterized by immersing the suture in a model in vitro environment under zero stress followed by measurement of the residual tensile strength as a function of immersion time. When in use, absorbable sutures are exposed to mechanical stress, which may affect the absorption rate; however, this phenomenon has not been adequately studied. The present work reports results of static fatigue tests in which the suture material is subjected to a mechanical load while immersed in a controlled environment and the time to fracture is measured as a function of the applied load. This approach is proved a viable method for obtaining a more detailed evaluation of absorbable suture performance. Copyright © 2017. Published by Elsevier Ltd.

  20. Laparoscopic gastrointestinal anastomoses using knotless barbed absorbable sutures are safe and reproducible: a single-center experience with 242 patients

    Science.gov (United States)

    Lee, Sang-Woong; Kawai, Masaru; Tashiro, Keitaro; Nomura, Eiji; Tokuhara, Takaya; Kawashima, Satoshi; Tanaka, Ryo; Uchiyama, Kazuhisa

    2016-01-01

    Objective Intracorporeal reconstruction of the digestive tract is technically challenging. The V-Loc 180 wound closure device (Covidien) is a self-anchoring unidirectional barbed suture that obviates the need for knot tying. The aim of this prospective cohort study was to investigate the use of the novel suture in gastrointestinal enterotomy closure. Methods The subjects comprised patients with malignant disease who were scheduled to undergo laparoscopic gastrectomy with curative intent. The barbed suture was used to close the entry hole for the linear stapler during intracorporeal reconstruction following laparoscopic gastric resection. The primary endpoint was the proportion of patients who developed anastomotic leakage at the site where the barbed suture was applied. Results Between July 2012 and March 2015, 242 patients were enrolled. Of 362 anastomoses, the enterotomy hole at 256 sites was closed using the barbed suture. These 256 sites consisted of 95 gastroduodenostomies, 25 gastrogastrostomies, 13 gastrojejunostomies, 90 jejunojejunostomies, 17 esophagojejunostomies and 16 primary closures of the stomach following local gastric resection. There were no anastomosis-related complications, conversion to usual sutures, mechanical closure of the entry hole and reoperation due to adhesive obstructions or mortality over a median follow-up period of 17.8 months. Conclusions The use of the unidirectional barbed absorbable suture for gastrointestinal closure is safe and effective in laparoscopic gastrectomy. PMID:26819279

  1. New sutures and suture anchors in sports medicine.

    Science.gov (United States)

    Alan Barber, F; Boothby, Michael H; Richards, David P

    2006-09-01

    Arthroscopic surgery requires appropriate surgical implants for effective fixation of tendons and ligaments to bone. Biodegradable suture anchors are being used with increasing frequency for various procedures in sports medicine. As companions to these biodegradable suture anchors, new sutures have been developed which possess greater strength and different material properties from the conventional braided polyester suture. Biodegradable polymers currently found in sutures and suture anchors include poly-L-lactic acid, poly-D, L lactic acid, polydioxanone, polyglycolic acid and their copolymers. Suture anchors are now available preloaded with a choice of conventional braided polyester sutures or some version of ultrahigh molecular weight polyethylene ("super") sutures. Most new suture anchors come with 2 sutures. The manner in which these sutures are attached to the anchor varies and may consist of 2 separate eyelets or 2 slots either parallel to one another or at different angles to one another. Some anchors have a very large single eyelet that allows for 2 or more sutures.

  2. Tissue adhesives for closure of surgical incisions.

    Science.gov (United States)

    Dumville, Jo C; Coulthard, Paul; Worthington, Helen V; Riley, Philip; Patel, Neil; Darcey, James; Esposito, Marco; van der Elst, Maarten; van Waes, Oscar J F

    2014-11-28

    Sutures (stitches), staples and adhesive tapes have been used for many years as methods of wound closure, but tissue adhesives have entered clinical practice more recently. Closure of wounds with sutures enables the closure to be meticulous, but the sutures may show tissue reactivity and can require removal. Tissue adhesives offer the advantages of an absence of risk of needlestick injury and no requirement to remove sutures later. Initially, tissue adhesives were used primarily in emergency room settings, but this review looks at the use of tissue adhesives in the operating room/theatre where surgeons are using them increasingly for the closure of surgical skin incisions. To determine the effects of various tissue adhesives compared with conventional skin closure techniques for the closure of surgical wounds. In March 2014 for this second update we searched the Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We did not restrict the search and study selection with respect to language, date of publication or study setting. Only randomised controlled trials were eligible for inclusion. We conducted screening of eligible studies, data extraction and risk of bias assessment independently and in duplicate. We expressed results as random-effects models using mean difference for continuous outcomes and risk ratios (RR) with 95% confidence intervals (CI) for dichotomous outcomes. We investigated heterogeneity, including both clinical and methodological factors. This second update of the review identified 19 additional eligible trials resulting in a total of 33 studies (2793 participants) that met the inclusion criteria. There was low quality evidence that sutures were significantly better than tissue adhesives for reducing the risk of wound breakdown (dehiscence; RR 3.35; 95% CI 1.53 to 7

  3. Adjustable suture strabismus surgery

    Science.gov (United States)

    Nihalani, B R; Hunter, D G

    2011-01-01

    Surgical management of strabismus remains a challenge because surgical success rates, short-term and long-term, are not ideal. Adjustable suture strabismus surgery has been available for decades as a tool to potentially enhance the surgical outcomes. Intellectually, it seems logical that having a second chance to improve the outcome of a strabismus procedure should increase the overall success rate and reduce the reoperation rate. Yet, adjustable suture surgery has not gained universal acceptance, partly because Level 1 evidence of its advantages is lacking, and partly because the learning curve for accurate decision making during suture adjustment may span a decade or more. In this review we describe the indications, techniques, and published results of adjustable suture surgery. We will discuss the option of ‘no adjustment' in cases with satisfactory alignment with emphasis on recent advances allowing for delayed adjustment. The use of adjustable sutures in special circumstances will also be reviewed. Consistently improved outcomes in the adjustable arm of nearly all retrospective studies support the advantage of the adjustable option, and strabismus surgeons are advised to become facile in the application of this approach. PMID:21760626

  4. Biomechanical evaluation of double Krackow sutures versus the three-loop pulley suture in a canine gastrocnemius tendon avulsion model.

    Science.gov (United States)

    Wilson, L; Banks, Ta; Luckman, P; Smith, B

    2014-11-01

    To compare two Krackow sutures with a three-loop pulley suture for the reattachment of canine gastrocnemius tendons, using a tendon avulsion model. In vitro biomechanical study. Ten paired gastrocnemius tendons were severed at their insertions on the calcaneal tuberosity and repaired with either two modified Krackow sutures or a modified three-loop pulley suture. Sutures were placed in the tendon ends and through diverging bone tunnels in the medial and lateral processes of the calcaneal tuberosity. Tensile loads required to (a) create a 3-mm gap and (b) induce construct failure were measured. The mean load to achieve a 3-mm gap was 77.22 ± 9.72 and 55.85 ± 9.91 N, and to result in construct failure was 106.88 ± 12.74 and 80.86 ± 12.23 N for the Krackow and three-loop pulley suture patterns, respectively. These differences were statistically significant (P sutures were superior to the three-loop pulley pattern in both resistance to 3-mm gap formation and load to failure in a canine gastrocnemius avulsion model. The prevention of gap formation is critical for the success of tenorrhaphy. These results indicate that a suture pattern using two Krackow sutures may be clinically superior to the three-loop pulley suture pattern in the repair of canine gastrocnemius avulsion. Further work is required to determine if this superiority is mirrored in the repair of other tendon avulsion or laceration scenarios. © 2014 Australian Veterinary Association.

  5. Are Barbed Sutures Associated With 90-day Reoperation Rates After Primary TKA?

    Science.gov (United States)

    Austin, Daniel C; Keeney, Benjamin J; Dempsey, Brendan E; Koenig, Karl M

    2017-11-01

    Studies have suggested that barbed sutures for wound closure in TKAs are an acceptable alternative to standard methods. However others have observed a higher risk of wound-related complications with barbed sutures. (1) Do 90-day TKA reoperation rates differ between patients undergoing a barbed suture arthrotomy closure compared with a traditional interrupted closure? (2) Do the 90-day reoperation rates of wound-related, deep infection, and arthrotomy failure complications differ between barbed suture and traditional closures? A retrospective analysis of a longitudinally maintained institutional primary TKA database was conducted on all TKAs performed between April 2011 and September 2015. We compared 884 primary TKAs, where the arthrotomy was closed with a barbed suture, with 1598 primary TKAs closed with the standard interrupted suture. After barbed sutures were introduced at our institution in 2012, the majority of surgeons gradually switched to barbed suture closures, with many using them exclusively by the end of the data collection period. We confirmed in-person followups and available data past 90 days for 97.4% (1556 of 1598) of the knees in patients with standard sutures and 94.8% (838 of 884) of the knees in patients with barbed sutures. Our primary endpoint was all-cause 90-day reoperation; our secondary endpoints considered: wound-related reoperation, as defined by previous studies; deep infection per Musculoskeletal Infection Society guidelines; and arthrotomy failure, defined intraoperatively as an opening or dehiscence through the previous arthrotomy closure. T tests and chi-square analyses were used to determine differences between the suture cohorts, and bivariate logistic regression was used to determine associations with our 90-day reoperation outcomes. With the numbers available, there was no association between suture type and 90-day all-cause reoperation (odds ratio [OR], 1.70; 95% CI, 0.82-3.53; p = 0.156). Suture type was not associated with

  6. Watertight dural closure! An in vitro study to explore the myth

    Directory of Open Access Journals (Sweden)

    Sudipkumar Sengupta

    2013-01-01

    Full Text Available Aim: The watertight closure of the dura mater is fundamental to intracranial supratentorial procedures in neurosurgery. Controversies exist claiming the superiority of one closure technique over another. But is ′Water-tight′ dural closure really achievable ? An in vitro study system was developed to test the pressures at which dural incisions, closed with sutures, leaked. Materials and Methods: Bovine dura was secured to the lower end of an open ended calibrated plastic cylinder. Multiple interrupted stitches were applied over a two 2 cm length of the dura without any incision. Similarly a 2 cm incision was made and closed with interrupted and continuous stitches. Cylinder was filled with colored saline gradually. Height of the water column at which sutured dura leaked was recorded. The tests were conducted with the dura both in lax and tense conditions. Inlay closure technique was also tested on the same model using a dural substitute. Results: Even without an incision, needle puncture sites over a dura, leak, at a very low hydrostatic pressure (30 < mm of H2O, though a continuous interlocking suture performs slightly better than an interrupted suture technique. If the needle puncture sites are closed with glue, both the suture techniques can achieve a watertight closure against a hydrostatic pressure of 240 mm of H2O. Conclusion : In the experimental model described, ′Water-tight′ dural closure appears to be impossible with suture closure of a dural defect.

  7. Fabrication and feasibility study of an absorbable diacetyl chitin surgical suture for wound healing.

    Science.gov (United States)

    Shao, Kai; Han, Baoqin; Gao, Jinning; Jiang, Zhiwen; Liu, Weizhi; Liu, Wanshun; Liang, Ye

    2016-01-01

    Diacetyl chitin (DAC) is an acidylated chitin obtained using acetic anhydride mixed perchloric acid system. By wet spinning and weaving technique, DAC has been successfully developed into a novel absorbable surgical suture. Thanks to the unique properties of chitins, the potential application of this novel monocomponent multifilament DAC suture may break the monopoly of synthetic polymer sutures in wound closure area. In this study, DAC was synthesized and characterized by multiple approaches including elemental analysis, Fourier transform infrared spectrometry (FTIR), and X-ray diffraction (XRD). In addition, we performed the feasibility assessment of DAC suture (USP 2-0) as absorbable suture for wound healing. Several lines of evidences suggested that DAC suture had comparable mechanical properties as synthetic polymer sutures. Moreover, DAC suture retained approximately 63% of the original strength at 14 days and completely absorbed in 42 days with no remarkable tissue reaction in vivo. Most important of all, DAC suture significantly promoted skin regeneration with faster tissue reconstruction and higher wound breaking strength on a linear incisional wound model. All these results demonstrated the potential use of DAC suture in short- or middle-term wound healing, such as epithelial and connective tissue. © 2015 Wiley Periodicals, Inc.

  8. Umbilical trocar site closure with Berci's needle after laparoscopic cholecystectomy.

    Science.gov (United States)

    Calik, Adnan; Yucel, Yusuf; Topaloglu, Serdar; Hos, Gultekin; Aktas, Aydin; Piskin, Burhan

    2008-01-01

    The umbilical region is particularly susceptible for development of incisional hernia after laparoscopic cholecystectomy (LC). To evaluate the effects of port-closure techniques on the complications seen after umbilical port-site closure, we compared closure with Berci's needle and the standard technique of a hand-sutured closure. A hundred patients underwent LC were randomly divided into two groups. We evaluated the required time for closure, the security of techniques and the factors affecting postoperative complications for both closure groups in a prospective manner. Closure of the umbilical port site was performed faster with the Berci's needle compared to standard hand-sutured technique. Postoperative hospital stay and complication rates were not altered significantly depend on the closure technique. Skin dimpling on the trocar site was observed predominantly after closure with Berci's needle. Spontaneous improvement on skin dimpling was observed within the 2 weeks after operation in all patients. During the follow-up period, there was no trocar site hernia observed in the study group. Closure of the umbilical port site with Berci's needle is found as an effective and safe method for laparoscopic cholecystectomy.

  9. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    Directory of Open Access Journals (Sweden)

    Swati R Yedke

    2013-01-01

    Full Text Available Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3 rd and 7 th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries.

  10. Comparison of different bronchial closure techniques following pneumonectomy in dogs

    OpenAIRE

    SALCI, Hakan; BAYRAM, A. Sami; Ozyigit, Ozgur; Gebitekin, Cengiz; Gorgul, O. Sacit

    2007-01-01

    The comparison of the histologic healing and bronchopleural fistula (BPF) complications encountered with three different BS closure techniques (manual suture, stapler and manual suture plus tissue flab) after pneumonectomy in dogs was investigated for a one-month period. The dogs were separated into two groups: group I (GI) (n = 9) and group II (GII) (n = 9). Right and left pneumonectomies were performed on the animals in GI and GII, respectively. Each group was further divided into three sub...

  11. Suture contamination in strabismus surgery.

    Science.gov (United States)

    Eustis, H Sprague; Rhodes, Annette

    2012-01-01

    To document the contamination rate of sutures used in strabismus surgery and evaluate the reduction of contamination using antibiotic-coated and antiseptic/antibiotic-coated sutures. This was a prospective randomized analysis of suture contamination and potential prophylaxis measures after strabismus surgery. Muscle sutures (6-0 polyglactin) used in 302 consecutive cases of strabismus from October 2008 to May 2009 were collected and randomly assigned to three groups: (1) a control without pretreatment sutures (61); (2) antibiotic/steroid-coated sutures (200); and (3) antiseptic-soaked and antibiotic/steroid-coated sutures (141). The sutures were used under sterile conditions and then cut into pieces and transferred to blood agar plates, which were incubated for 48 hours and then checked for growth. Group 1 had bacterial growth in 17 of 61 (28%) sutures; group 2 had growth in 44 of 200 (22%) sutures; and group 3 had growth in 12 of 141 (9%) sutures. The reduction in bacterial growth using the antibiotic/antiseptic coating was significant (P = .006). One patient developed coagulase-negative Staphylococcus epidermidis endophthalmitis 1 week after surgery, which was promptly diagnosed and successfully treated. No complications from the antibiotic-coated or antiseptic-soaked sutures were noted. Although endophthalmitis after strabismus surgery is rare, estimated at 1 in 35,000 to 1 in 185,000, visual outcome is uniformly poor. The authors hypothesize that strabismus sutures can be contaminated via contact with the eyelashes and skin, providing a possible conduit for endophthalmitis. Bacterial contamination of strabismus sutures is high (28%) and can be reduced significantly if sutures are soaked in antiseptic before use. Copyright 2012, SLACK Incorporated.

  12. Clinical inquiries. How does tissue adhesive compare with suturing for superficial lacerations?

    Science.gov (United States)

    Aukerman, Douglas F; Sebastianelli, Wayne J; Nashelsky, Joan

    2005-04-01

    Tissue adhesives are effective and yield results comparable to those with conventional suturing of superficial, linear, and low-tension lacerations. The cosmetic outcome is similar; wound complications, such as infection and dehiscence, may be lower with tissue adhesives. Wound closure of superficial lacerations by tissue adhesives is quicker and less painful compared with conventional suturing (strength of recommendation: A, systematic reviews of randomized trials).

  13. Healing of periodontal flaps when closed with silk sutures and N-butyl cyanoacrylate: A clinical and histological study

    Directory of Open Access Journals (Sweden)

    Kulkarni Sudhindra

    2007-01-01

    Full Text Available Background: The closure of the periodontal flaps post-surgery is a necessity for attainment of a primary union between the flap margins and the establishment of a healthy dentogingival junction. N-butyl cyanoacrylate is a tissue adhesive, which can be used for the closure of the incised wounds to overcome the problems associated with conventional suture materials like silk. Objective: The present study was carried out to assess the healing of the periodontal flaps when closed with the conventional silk sutures and N-butyl cyanoacrylate. Materials and Methods: The study was carried out on 24 patients who needed flap surgical procedure for pocket therapy. Results: It was found that healing with the cyanoacrylate is associated with less amount of inflammation during the first week when compared with silk. However, over a period of 21 days to 6 weeks, the sites treated with both the materials showed similar healing patterns. Conclusion: It can be concluded that cyanoacrylate aids in early initial healing.

  14. Releasable suture technique for trabeculectomy

    Directory of Open Access Journals (Sweden)

    Jacob Pushpa

    1993-01-01

    Full Text Available We studied the effect of the releasable suture technique on immediate postoperative intraocular pressure (IOP. Nine eyes of nine patients with glaucoma had trabeculectomy with a releasable suture. In the six eyes that did not receive antimitotics, the suture was released by the fifth postoperative day; in the others suture release was delayed up to the fourteenth day. Of the nine patients, one had an acceptable postoperative IOP and did not need suture release; in another the suture broke and could not be released. In the remaining seven patients, the difference between the pre-release and post-release IOP was statistically significant (p < 0.001. The complications of this technique include failed suture release, subconjunctival hematoma and a distinctive "windshield wiper" keratopathy.

  15. Analysis of suture anchor eyelet position on suture failure load.

    Science.gov (United States)

    Aktay, Sevima A; Kowaleski, Michael P

    2011-06-01

    To compare mechanical performance of 2 orientations of the 5 mm Corkscrew® suture anchor with #5 Fiberwire® . In vitro biomechanical study. Suture anchor-suture constructs (n=40). Acute and cyclic tensile loads were applied to suture threaded through eyelets of 40 anchors perpendicular to the long axis of the anchor. Eyelets were positioned so that the suture pull was in line with (anchor rotation angle of 0° [ARA 0]) or 90° (ARA 90) to the eyelet plane. Load at failure, stiffness, and cycles to failure were determined. All constructs failed by suture breakage at the eyelet. Mean load at failure was significantly higher in the ARA 90 group (634 ± 93 N) compared with the ARA 0 group (495 ± 52 N; P=.0015). No significant difference was found between groups for mean number of cycles to failure (270 ± 177 versus 178 ± 109; P=.2166) and stiffness (50 ± 4 versus 48 ± 5 N/mm; P=.3141). The Corkscrew® 5 mm suture anchor with Fiberwire® suture fails via suture breakage at the eyelet under higher acute loads if the suture is loaded at an angle of 90° compared with 0° with respect to the plane of the eyelet. © Copyright 2011 by The American College of Veterinary Surgeons.

  16. Early intraocular pressure change after peripheral iridotomy with ultralow fluence pattern scanning laser and Nd:YAG laser in primary angle-closure suspect: Kowloon East Pattern Scanning Laser Study Report No. 3.

    Science.gov (United States)

    Chan, Jeffrey Chi Wang; Choy, Bonnie Nga Kwan; Chan, Orlando Chia Chieh; Li, Kenneth Kai Wang

    2018-02-01

    Our purpose was to assess the early intraocular pressure (IOP) changes of ultralow fluence laser iridotomy using pattern scanning laser followed by neodymium:yttrium-aluminum-gamet (Nd:YAG) laser. This is a prospective interventional study. Thirty-three eyes of 33 adult Chinese primary angle-closure suspect subjects were recruited for prophylactic laser peripheral iridotomy. Sequential laser peripheral iridotomy was performed using pattern scanning laser followed by Nd:YAG laser. Visual acuity (VA) and IOP were measured before treatment, at 1 h, 1 day, 1 week, 1 month, 3 months and 6 months after laser. Laser energy used and complications were documented. Corneal endothelial cell count was examined at baseline and 6 months. Patency of the iridotomy was assessed at each follow-up visit. All subjects achieved patent iridotomy in a single session. The mean energy used was 0.335+/-0.088 J for the pattern scanning laser, and 4.767+/-5.780 mJ for the Nd:YAG laser. The total mean energy was 0.339+/-0.089 J. None of the eyes developed a clinically significant IOP spike (≥ 8 mmHg) at 1 h and 1 day after laser use. Only four eyes developed higher IOP at 1 h and all were ≤3 mmHg compared to baseline. The mean IOP was 13.8+/-2.5 mmHg at 1 h and 11.5+/-2.2 mmHg at 1 day, both were significantly lower than baseline (15.8+/-2.1 mmHg) (P angle-closure suspects. Further studies to investigate its role in the treatment of other angle-closure conditions are warranted.

  17. Refractive stability after cataract extraction using a 6.5-millimeter scleral pocket incision with horizontal or radial sutures.

    Science.gov (United States)

    Werblin, T P

    1994-01-01

    Radial suturing of 6.5-millimeter scleral tunnel incisions following cataract surgery can create significant with-the-rule astigmatism in the immediate postoperative period. Because of the significant visual distortion and slow visual recovery seen with radial suturing, this study was undertaken to compare two other suturing techniques which induce lesser amounts of with-the-rule astigmatism in the immediate postoperative period. The refractive behavior of eyes closed with loose radial sutures and with horizontal sutures was compared to the behavior of eyes closed with the more traditional "tight" radial sutures following phacoemulsification surgery. Eyes sutured with loosely tied radial sutures demonstrated minimal with-the-rule cylinder immediately following surgery (1.25 D) and showed a more rapid stabilization of astigmatism than did the eyes tied with tight radial sutures, 2 months versus up to 6 months. However, the eyes tied with horizontal sutures, which showed no induced with-the-rule astigmatism at the time of surgery, showed even more rapid stabilization between 5 days and 1 month from the time of surgery. To get the most rapid visual rehabilitation following cataract surgery, a wound closure which generates no induced with-the-rule cylinder such as horizontal sutures would be required.

  18. Abdominal wound closure: current perspectives

    Directory of Open Access Journals (Sweden)

    Williams ZF

    2015-12-01

    Full Text Available Zachary F Williams, William W Hope Department of Surgery, South East Area Health Education Center, New Hanover Regional Medical Center, Wilmington, NC, USA Abstract: This review examines both early and late wound complications following laparotomy closure, with particular emphasis on technical aspects that reduce hernia formation. Abdominal fascial closure is an area of considerable variation within the field of general surgery. The formation of hernias following abdominal wall incisions continues to be a challenging problem. Ventral hernia repairs are among the most common surgeries performed by general surgeons, and despite many technical advances in the field, incisional hernia rates remain high. Much attention and research has been directed to the surgical management of hernias. Less focus has been placed on prevention of hernia formation despite its obvious importance. This review examines the effects of factors such as the type of incision, suture type and size, closure method, patient risk factors, and the use of prophylactic mesh. Keywords: incisional, abdominal, hernia, prevention, wound closure techniques 

  19. Quantitative physical and handling characteristics of novel antibacterial braided silk suture materials.

    Science.gov (United States)

    Chen, Xiaojie; Hou, Dandan; Tang, Xiaoqi; Wang, Lu

    2015-10-01

    Surgical braided silk sutures have been widely used because these materials exhibit good handling characteristics, ease of use, and ideal knot security. However, surgical silk sutures likely cause surgical site infections because these sutures are composed of natural protein materials with a braided structure. As such, antibacterial silk sutures for clinical wound closure should be developed. Braided silk suture could be treated and modified with antibacterial agent, provided that excellent physical and handling characteristics of this material should maximize maintained. This study aimed to quantitatively investigate the effect of antibacterial treatment with different parameters on physical and handling characteristics of novel antibacterial braided silk sutures. Physical and handling characteristics, including appearance, knot-pull tensile strength, pullout friction resistance, tissue drag friction resistance, and bending stiffness, were evaluated. After physical and handling tests were conducted, images showed morphological characteristics were obtained and evaluated to investigate the relationship between antibacterial treatment and physical and handling properties. Results showed that suture diameter increased and reached the nearest thick size specification; knot-pull tensile strength decreased but remained higher than the standard value by at least 40.73%. Fracture asynchronism during knot-pull tensile strength test suggested that the fineness ratio of shell and core strands may enhance knot-pull tensile strength. Static and dynamic frictions of suture-to-suture friction behavior were slightly affected by antibacterial treatment, and changed to less than 16.07% and 32.77%, respectively. Suture-to-tissue friction and bending stiffness increased by approximately 50%; the bending stiffness of the proposed suture remained efficient compared with that of synthetic sutures. Therefore, good physical and handling characteristics can be maintained by selecting

  20. Holding Strength of a Hem-o-lok/Lapra-Ty Clip Combination on Sutures Used During Partial Nephrectomy.

    Science.gov (United States)

    Paka, Bikal; Bossemeyer, Robert; Tourojman, Mouafak; Gupta, Ruchir; Lane, Brian R

    2017-09-01

    To investigate the anti-slip strength of closing systems employing sutures terminated with a Hem-o-lok/Lapra-Ty clip combination to determine which sutures perform best for this application. Partial nephrectomy is the reference standard for treatment of small renal masses. The main disadvantage of partial nephrectomy is the risk of technical complications, including renorrhaphy site bleeding and urine leak. A materials testing system produced a constant velocity pull on the free end of an anchored suture. A Lapra-Ty clip was attached 1 cm from the end of each suture as a backstop for the Hem-o-lok. A digital force gauge measured the tension that was applied until the suture slipped in the closing system. Vicryl, Monocryl, Chromic, Stratafix, and V-Loc sutures of diameters 1 to 4-0 were tested (n = 7 for each suture type, 161 total experiments). The holding strength of a Lapra-Ty/Hem-o-lok clip combination is lowest for Vicryl 4-0 (4.3 ± 1.4N) and highest for Monocryl 0 (16.5 ± 1.6N) sutures. Larger sutures (1 and 0) hold at higher tensions than sutures with smaller dimensions (4-0 and 3-0). For 2-0 sutures, the holding strength was 5.7N with Vicryl, 13.8N with Stratafix, and 15.9N with V-Loc sutures. The mean values of holding tension of this anchoring system for all sutures tested was greater than the amount found to be sufficient for tissue closure in previous studies (3.2N). Barbed sutures (Stratafix, V-Loc) appeared to have superior holding strength when compared with most standard sutures; barb orientation does not influence holding tension. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Meta-analysis on Materials and Techniques for Laparotomy Closure: The MATCH Review.

    Science.gov (United States)

    Henriksen, N A; Deerenberg, E B; Venclauskas, L; Fortelny, R H; Miserez, M; Muysoms, F E

    2018-01-10

    The aim of this systematic review and meta-analysis was to evaluate closure materials and suture techniques for emergency and elective laparotomies. The primary outcome was incisional hernia after 12 months, and the secondary outcomes were burst abdomen and surgical site infection. A systematic literature search was conducted until September 2017. The quality of the RCTs was evaluated by at least 3 assessors using critical appraisal checklists. Meta-analyses were performed. A total of 23 RCTs were included in the meta-analysis. There was no evidence from RCTs using the same suture technique in both study arms that any suture material (fast-absorbable/slowly absorbable/non-absorbable) is superior in reducing incisional hernias. There is no evidence that continuous suturing is superior in reducing incisional hernias compared to interrupted suturing. When using a slowly absorbable suture for continuous suturing in elective midline closure, the small bites technique results in significantly less incisional hernias than a large bites technique (OR 0.41; 95% CI 0.19, 0.86). There is no high-quality evidence available concerning the best suture material or technique to reduce incisional hernia rate when closing a laparotomy. When using a slowly absorbable suture and a continuous suturing technique with small tissue bites, the incisional hernia rate is significantly reduced compared with a large bites technique.

  2. The Morphogenesis of Cranial Sutures in Zebrafish.

    Directory of Open Access Journals (Sweden)

    Jolanta M Topczewska

    Full Text Available Using morphological, histological, and TEM analyses of the cranium, we provide a detailed description of bone and suture growth in zebrafish. Based on expression patterns and localization, we identified osteoblasts at different degrees of maturation. Our data confirm that, unlike in humans, zebrafish cranial sutures maintain lifelong patency to sustain skull growth. The cranial vault develops in a coordinated manner resulting in a structure that protects the brain. The zebrafish cranial roof parallels that of higher vertebrates and contains five major bones: one pair of frontal bones, one pair of parietal bones, and the supraoccipital bone. Parietal and frontal bones are formed by intramembranous ossification within a layer of mesenchyme positioned between the dermal mesenchyme and meninges surrounding the brain. The supraoccipital bone has an endochondral origin. Cranial bones are separated by connective tissue with a distinctive architecture of osteogenic cells and collagen fibrils. Here we show RNA in situ hybridization for col1a1a, col2a1a, col10a1, bglap/osteocalcin, fgfr1a, fgfr1b, fgfr2, fgfr3, foxq1, twist2, twist3, runx2a, runx2b, sp7/osterix, and spp1/ osteopontin, indicating that the expression of genes involved in suture development in mammals is preserved in zebrafish. We also present methods for examining the cranium and its sutures, which permit the study of the mechanisms involved in suture patency as well as their pathological obliteration. The model we develop has implications for the study of human disorders, including craniosynostosis, which affects 1 in 2,500 live births.

  3. Interactive Virtual Suturing Simulations: Enhancement of Student Learning in Veterinary Medicine

    Science.gov (United States)

    Staton, Amy J.; Boyd, Christine B.

    2013-01-01

    This capstone addresses an instructional gap in the Morehead State University Veterinary Technology Program and in other similar programs around the globe. Students do not retain the knowledge needed to proficiently complete suture patterns nor do students receive sufficient instructional time during the year to master each suture pattern that is…

  4. Effect of the suture technique on postoperative pain, swelling and trismus after removal of lower third molars: A randomized clinical trial.

    Science.gov (United States)

    Gay-Escoda, Cosme; Gómez-Santos, Laila; Sánchez-Torres, Alba; Herráez-Vilas, José-María

    2015-05-01

    To evaluate the intensity of pain, swelling and trismus after the removal of impacted lower third molars comparing two different suture techniques of the triangular flap: the complete suture of the distal incision and relieving incision and the partial suture with only one suture knot for closure of the corner of the flap and the closure of the distal incision, without suturing the relieving incision. A prospective, randomized, cross-over clinical trial was conducted in 40 patients aged from 18 to 45 years who underwent surgical extraction of impacted lower third molars at the Department of Oral Surgery in the Odontological Hospital of the University of Barcelona during the year 2011. Patients were randomly divided in 2 groups. Two different techniques (hermetical closure and partial closure of the wound) were performed separated by a one month washout period in each patient. Postoperative pain, swelling and trismus were evaluated prior to the surgical procedure and also at 2 and 7 days postoperatively. No statistically significant differences were observed for pain (ptrismus (p<0.71) and swelling (p<0.05) between the test and the control group. However, the values of the three parameters related to the test group were lower than those for the control group. Partial closure of the flap without suturing the relieving incision after surgical extraction of lower third molars reduces operating time and it does not produce any postoperative complications compared with complete closure of the wound.

  5. Nasal tip sutures: Techniques and indications.

    Science.gov (United States)

    Cingi, Cemal; Muluk, Nuray Bayar; Ulusoy, Seçkin; Söken, Hakan; Altıntoprak, Niyazi; Şahin, Ethem; Ada, Servet

    2015-01-01

    The surgical anatomy of the nasal tip is determined by intrinsic factors, such as the nasal tip volume, shape, definition, and symmetry. These factors are intimately related to the morphology of the lower lateral cartilages. Tip sutures reduce the need for grafts and allow the surgeon to manipulate the tip with a high degree of precision and better long-term clinical outcomes. In this review, we evaluated common nasal tip suture techniques to clarify the similarities and differences among them. The following nasal tip suture techniques were investigated: medial crural fixation suture, middle crura suture, transdomal (dome creating, dome binding, domal definition) suture, interdomal suture, lateral crural mattress suture, columella septal suture, intercrural suture, tip rotation suture, craniocaudal transdomal suture, lateral crural spanning suture, suspension suture, tongue-in-groove technique, and lateral crural steal. Tip sutures increase tip projection, narrow the tip, provide stabilization, and provide tip rotation. The sutures may be used separately or together. Nasal tip sutures have long been used as noninvasive suture techniques. Each suture technique has unique benefits, and various key points must be considered when using these techniques.

  6. Restaurant closures

    CERN Document Server

    Novae Restauration

    2012-01-01

    Christmas Restaurant closures Please note that the Restaurant 1 and Restaurant 3 will be closed from Friday, 21 December at 5 p.m. to Sunday, 6 January, inclusive. They will reopen on Monday, 7 January 2013.   Restaurant 2 closure for renovation To meet greater demand and to modernize its infrastructure, Restaurant 2 will be closed from Monday, 17 December. On Monday, 14 January 2013, Sophie Vuetaz’s team will welcome you to a renovated self-service area on the 1st floor. The selections on the ground floor will also be expanded to include pasta and pizza, as well as snacks to eat in or take away. To ensure a continuity of service, we suggest you take your break at Restaurant 1 or Restaurant 3 (Prévessin).

  7. Triclosan-coated sutures reduce wound infections after spinal surgery: a retrospective, nonrandomized, clinical study.

    Science.gov (United States)

    Ueno, Masaki; Saito, Wataru; Yamagata, Megumu; Imura, Takayuki; Inoue, Gen; Nakazawa, Toshiyuki; Takahira, Naonobu; Uchida, Kentaro; Fukahori, Nobuko; Shimomura, Kiyomi; Takaso, Masashi

    2015-05-01

    Surgical site infection (SSI) is a serious postoperative complication. The incidence of SSIs is lower in clean orthopedic surgery than in other fields, but it is higher after spinal surgery, reaching 4.15% in high-risk patients. Several studies reported that triclosan-coated polyglactin 910 sutures (Vicryl Plus; Ethicon, Inc., Somerville, NJ, USA) significantly reduced the infection rate in the general surgical, neurosurgical, and thoracic surgical fields. However, there have been no studies on the effects of such coated sutures on the incidence of SSIs in orthopedics. To compare the incidence of wound infections after spinal surgery using triclosan-coated suture materials with that of noncoated ones. A retrospective, nonrandomized, and clinical study. From May 2010 to April 2012, 405 patients underwent a spinal surgical procedure in the Department of Orthopedic Surgery of two university hospitals. The primary outcome was the number of wound infections and dehiscences. Two hundred five patients had a conventional wound closure with polyglactin 910 suture (Vicryl) between May 2010 and April 2011 (Time Period 1 [TP1]), and 200 patients underwent wound closure with triclosan-coated polyglactin 910 suture (Vicryl Plus) between May 2011 and April 2012 (TP2). Statistical comparisons of wound infections, dehiscence, and risk factors for poor wound healing or infection were performed. None of the authors has any conflict of interest associated with this study. There were two cases of wound dehiscence in TP1 and one in TP2 (p=.509). Using noncoated sutures in TP1, eight patients (3.90%) had wound infections, whereas one patient (0.50%) had wound infections in TP2 (using triclosan-coated sutures); the difference was significant (p=.020). The use of triclosan-coated polyglactin 910 sutures instead of polyglactin 910 sutures may reduce the number of wound infections after spinal surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Force sensing in surgical sutures

    NARCIS (Netherlands)

    Horeman, T.; Meijer, E.J.; Harlaar, J.J.; Lange, J.F.; Van den Dobbelsteen, J.J.; Dankelman, J.

    2013-01-01

    The tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to describe the

  9. Force sensing in surgical sutures

    NARCIS (Netherlands)

    T. Horeman (Tim); E.-J. Meijer (Evert-Jan); J.J. Harlaar (Joris Jan); J.F. Lange (Johan); J.J. van den Dobbelsteen (John); J. Dankelman (Jenny)

    2013-01-01

    textabstractThe tension in a suture is an important factor in the process of wound healing. If there is too much tension in the suture, the blood flow is restricted and necrosis can occur. If the tension is too low, the incision opens up and cannot heal properly. The purpose of this paper is to

  10. Unravelling the molecular control of calvarial suture fusion in children with craniosynostosis

    Directory of Open Access Journals (Sweden)

    Morris C Phillip

    2007-12-01

    Full Text Available Abstract Background Craniosynostosis, the premature fusion of calvarial sutures, is a common craniofacial abnormality. Causative mutations in more than 10 genes have been identified, involving fibroblast growth factor, transforming growth factor beta, and Eph/ephrin signalling pathways. Mutations affect each human calvarial suture (coronal, sagittal, metopic, and lambdoid differently, suggesting different gene expression patterns exist in each human suture. To better understand the molecular control of human suture morphogenesis we used microarray analysis to identify genes differentially expressed during suture fusion in children with craniosynostosis. Expression differences were also analysed between each unfused suture type, between sutures from syndromic and non-syndromic craniosynostosis patients, and between unfused sutures from individuals with and without craniosynostosis. Results We identified genes with increased expression in unfused sutures compared to fusing/fused sutures that may be pivotal to the maintenance of suture patency or in controlling early osteoblast differentiation (i.e. RBP4, GPC3, C1QTNF3, IL11RA, PTN, POSTN. In addition, we have identified genes with increased expression in fusing/fused suture tissue that we suggest could have a role in premature suture fusion (i.e. WIF1, ANXA3, CYFIP2. Proteins of two of these genes, glypican 3 and retinol binding protein 4, were investigated by immunohistochemistry and localised to the suture mesenchyme and osteogenic fronts of developing human calvaria, respectively, suggesting novel roles for these proteins in the maintenance of suture patency or in controlling early osteoblast differentiation. We show that there is limited difference in whole genome expression between sutures isolated from patients with syndromic and non-syndromic craniosynostosis and confirmed this by quantitative RT-PCR. Furthermore, distinct expression profiles for each unfused suture type were noted, with

  11. Tarsal platform show after upper eyelid blepharoplasty with or without brassiere sutures

    Directory of Open Access Journals (Sweden)

    Marisa Novaes de Figueiredo

    Full Text Available ABSTRACT Purpose: Increased tarsal platform show (TPS and decreased brow fat span (BFS are associated with favorable results in women undergoing cosmetic blepharoplasty. We conducted a study to evaluate the efficacy of upper blepharoplasty with or without a technique (brassiere sutures to increase TPS and decrease BFS. Methods: This is a prospective, randomized, comparative, case series study of 100 eyelids (50 consecutive women patients treated with cosmetic upper blepharoplasty performed by a single surgeon. Patients were randomized to receive traditional upper blepharoplasty with a single running suture skin closure versus orbicularis oculi muscle fixation to the periosteum (brassiere sutures prior to skin closure. Data on patient age, duration of follow-up, complications, and treatment were analyzed. The mean TPS, mean BFS, and mean TPS/BFS ratio were measured at three anatomic landmarks before and after surgery. Results: Fifty-six eyelids (28 patients were treated with traditional single suture blepharoplasty, and 44 eyelids (22 patients had brassiere sutures. In both groups, paired t-tests indicate significant differences between preoperative and postoperative evaluations (p0.05. Conclusions: Brassiere sutures during upper blepharoplasty and traditional blepharoplasty were associated with postoperative increase in TPS, decrease in BFS, and increase in TPS/BFS, without statistically significant differences between these surgeries.

  12. Watertight dural closure! An in vitro study to explore the myth

    OpenAIRE

    Sudipkumar Sengupta

    2013-01-01

    Aim: The watertight closure of the dura mater is fundamental to intracranial supratentorial procedures in neurosurgery. Controversies exist claiming the superiority of one closure technique over another. But is ′Water-tight′ dural closure really achievable ? An in vitro study system was developed to test the pressures at which dural incisions, closed with sutures, leaked. Materials and Methods: Bovine dura was secured to the lower end of an open ended calibrated plastic cylinder. Multiple int...

  13. Bioactive Sutures: A Review of Advances in Surgical Suture Functionalisation.

    Science.gov (United States)

    Alshomer, Feras; Madhavan, Arul; Pathan, Omar; Song, Wenhui

    2017-01-01

    Sutures have been at the forefront of surgical medicine throughout time. With recent advances in suture technology, it is possible to incorporate biologically active substances to enhance suture function and capability. Bioactive sutures represent a modality interest in controlled drug and cell delivery to traumatic sites. In this article, a comprehensive literature search of key bibliographic databases focusing on suture material fabrication and advanced modification was performed. The history, manufacturing process and cost-effectiveness of bioactive sutures are presented. Several novel modifications to enhance function in drug and growth factor delivery and cell therapy are also reviewed. Different antimicrobial drugs and anaesthetics have been shown to be effective in reducing inflammation and bacterial infection. Cellular therapy represents a unique modality augmenting the surgical repair of various soft tissue injuries. We propose a definition of bio-active sutures as biomaterials that are engineered to have controlled tissue interaction to optimise wound/defect healing, in addition to their essential function in tissue approximation. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. Randomized trial of antimicrobial-coated sutures to prevent surgical site infection after breast cancer surgery.

    Science.gov (United States)

    Williams, Nia; Sweetland, Helen; Goyal, Sumit; Ivins, Nicola; Leaper, David J

    2011-12-01

    Surgical site infection (SSI) is the fourth commonest healthcare-associated infection and complicates at least 5% of open operations. In a randomized clinical trial, antimicrobial-coated sutures were compared with their conventional counterparts, polyglactin and poliglecaprone, for skin closure after breast cancer surgery to assess their role in reducing the rate of SSI. Between November 2008 and February 2011, 150 female patients presenting with breast cancer to a single center were randomized to skin closure with antimicrobial-coated or plain sutures. Postoperatively, SSI was defined using the U.S. Centers for Disease Control and Prevention (CDC) definitions and scored using the ASEPSIS or Southampton systems by trained, blinded observers with close post-discharge surveillance and patient diaries. Surgeons and patients were blinded to the type of suture used. Using CDC criteria, the overall rate of SSI was 18.9% at six weeks. Six patients (4.7%) needed intervention or readmission for SSI. Skin closure with antimicrobial sutures showed a non-statistically significant reduction in the SSI rate, to 15.2%, compared with conventional sutures (22.9%). A uniform tendency for fewer SSIs in the antimicrobial-coated suture group was found using ASEPSIS and Southampton scores, but again, the difference was not statistically significant. The previously reported high rate of SSI related to breast surgery was confirmed. Using statistical modeling and earlier reports, the study was powered to show a difference using ASEPSIS scores, but the modification used in this trial failed to find a difference. Finding a statistically significant difference would have needed two to three times the number of patients recruited. Further evaluation of antimicrobial-coated sutures is merited, particularly if used as part of a care bundle to reduce SSI after breast cancer surgery.

  15. Closing and non-closing sutures in 256 crania of known age and sex from Amsterdam (a.d. 1883–1909)

    NARCIS (Netherlands)

    Perizonius, W.R.K.

    1984-01-01

    By dividing a Dutch reference collection into two subsamples of different ages, remarkable differences were found in the suture closure process in these subsamples. Spearman rank correlations demonstrated that mean endocranial closure stage is correlated (P<0·001) with age in the ages below fifty

  16. study of intraperitoneal closure and closure after temporary

    African Journals Online (AJOL)

    sions were closed in two layers using chromic catgut (ccg) suture size 2, followed by ccg suture size 00 for the peritoneal layers. The rectus sheet was closed continuously using ccg suture size 1 and plain ccg suture size 00 for the apposition of subcutaneous layer. The skin was closed subcuticularly with nylon suture size 0.

  17. The removal of 10/0 polyester (Mersilene) sutures after small incision congenital cataract surgery.

    Science.gov (United States)

    Bar-Sela, S M; Spierer, O; Spierer, A

    2008-01-01

    To evaluate the use of 10/0 polyester (Mersilene) sutures for closure of small corneal incision after congenital cataract surgery. The authors retrospectively reviewed the medical records of 58 cases (42 patients) who underwent congenital cataract extraction and intraocular lens implantation between 1999 and 2004, using Mersilene sutures. An examination looking for suture-related complications and retinoscopy was done 1 week after surgery and then every month for 6 months. The sutures were removed in cases of local tissue reaction, but not due to high postoperative astigmatism. Paired t-test was used to compare patients' age and astigmatism level in those cases who had suture removal (Group 1) as opposed to those who did not (Group 2). In 10 cases (17%) corneal vascularization, necessitating suture removal, was found during 6-month follow-up period, without the trigger of loose suture. Patient age was 3.5+/-3.3 years and 4.4+/3.3 years in Groups 1 and 2, respectively. At 1 week postoperatively the astigmatism value was 1.7+/-1.7 diopter (D) and 2.3+/-2.2 D in Groups 1 and 2, respectively, and it reduced to 0.9+/-0.8 in both groups at 6 months postoperatively. One case of endophthalmitis was encountered 2 days after suture removal. Removal of Mersilene sutures after congenital cataract surgery is required in cases of corneal vascularization, occurring during the first months postoperatively. Owing to the risk of general anesthesia and infection, suture removal should be considered with caution in cases of postoperative astigmatism.

  18. Changes in biomechanical strain and morphology of rat calvarial sutures and bone after Tgf-β3 inhibition of posterior interfrontal suture fusion.

    Science.gov (United States)

    Shibazaki-Yorozuya, Reiko; Wang, Qian; Dechow, Paul C; Maki, Koutaro; Opperman, Lynne A

    2012-06-01

    Craniofacial sutures are bone growth fronts that respond and adapt to biomechanical environments. Little is known of the role sutures play in regulating the skull biomechanical environment during patency and fusion conditions, especially how delayed or premature suture fusion will impact skull biomechanics. Tgf-β3 has been shown to prevent or delay suture fusion over the short term in rat skulls, yet the long-term patency or its consequences in treated sutures is not known. It was therefore hypothesized that Tgf-β3 had a long-term impact to prevent suture fusion and thus alter the skull biomechanics. In this study, collagen gels containing 3 ng Tgf-β3 were surgically placed superficial to the posterior interfrontal suture (IFS) and deep to the periosteum in postnatal day 9 (P9) rats. At P9, P24, and P70, biting forces and strains over left parietal bone, posterior IFS, and sagittal suture were measured with masticatory muscles bilaterally stimulated, after which the rats were sacrificed and suture patency analyzed histologically. Results demonstrated that Tgf-β3 treated sutures showed less fusion over time than control groups, and strain patterns in the skulls of the Tgf-β3-treated group were different from that of the control group. Although bite force increased with age, no alterations in bite force were attributable to Tgf-β3 treatment. These findings suggest that the continued presence of patent sutures can affect strain patterns, perhaps when higher bite forces are present as in adult animals. Copyright © 2012 Wiley Periodicals, Inc.

  19. Effectiveness of ultrasonographic evaluation of the cranial sutures in children with suspected craniosynostosis

    Energy Technology Data Exchange (ETDEWEB)

    Simanovsky, Natalia; Hiller, Nurith; Koplewitz, Benjamin; Rozovsky, Katya [Hadassah Hebrew University Medical Center, Department of Medical Imaging, Mount, Scopus, P.O. Box 24035, Jerusalem (Israel)

    2009-03-15

    Computed tomography (CT) is the 'gold standard' for evaluation of the cranial sutures. While prenatal cranial suture evaluation with ultrasound (US) is common, US has not been established as a postnatal screening tool. We evaluated the effectiveness of US for diagnosis of craniosynostosis (CS). During 2006, 24 infants with questionable CS were assessed with US of the sagittal, metopic, and bilateral coronal and lambdoid sutures. US findings and clinical records were reviewed retrospectively. Sixteen boys and eight girls (ages 1-11 months, mean 4.3) underwent US. The correct diagnosis was provided in 23 (95%), with equivocal findings in one patient. Cranial sutures appeared normal in 15 infants, who had normal clinical presentation at mean 5.8 months follow-up; CT confirmation was obtained in two. In eight children, US identified premature closure of one or more cranial sutures. Three-dimensional CT was performed as a preparation for surgery in four, with classical CS findings. In one case with inconclusive US findings, CT showed narrow but open sutures. Sonographic examination of cranial sutures may serve as a first imaging tool for evaluation of craniosynostosis. CT may be reserved for children with abnormal or equivocal ultrasound and for preoperative planning. (orig.)

  20. Assessment of midpalatal suture ossification using cone-beam computed tomography.

    Science.gov (United States)

    Haghanifar, Sina; Mahmoudi, Sadaf; Foroughi, Ramin; Mir, Arash Poorsattar Bejeh; Mesgarani, Abas; Bijani, Ali

    2017-03-01

    The degree of ossification of the midpalatal suture is an important factor in the selection of treatment procedure, especially in young individuals. Considering the discrepancies in the results of studies on the exact time of the closure of this suture, the present study was undertaken to evaluate ossification and morphology of the suture with the use of CBCT. In the present cross-sectional study, the CBCT images of the maxilla in 144 Iranian subjects (72 males, 72 females) with an age range of 10 to 70 years, referring to a private radiology center in Sari, Iran, were evaluated. The CBCT images were evaluated in the axial cross-sectional slice at 1 mm intervals to determine morphology and the maturation stage of the suture and its degree of ossification. The six developmental stages that were observed were as follows: stage A, a direct line without disturbances; stage B, a scalloped appearance in the suture; stage C, two parallel lines with a scalloped appearance that were connected at some points; stage CD, the anterior portion was similar to stage C, and the posterior region was similar to stage D; stage D, ossification only in the palatine bone; stage E, complete ossification of the suture. The degree of ossification of the suture was calculated with the use of the ratio of the length of the ossified segment to the entire length of the suture. Data were analyzed with Spearman's correlation test, Chi-squared test, t-test, ANOVA, Mann-Whitney U, and Kruskal-Wallis test. Intra-observer agreement was calculated with the use of weighted kappa coefficient. Data were analyzed with SPSS 17. There was a strong correlation between the age groups and the developmental stages of the midpalatal suture in both genders (r=0.681, ptwo genders (p=0.193). Although the rate of suture closure increased with aging, age was not a reliable factor alone to determine the developmental stage of the suture. Use of CBCT is necessary in all the patients to determine the degree of

  1. Preclinical study evaluating a novel trocar site closure system

    Directory of Open Access Journals (Sweden)

    Walker PA

    2016-04-01

    Full Text Available Peter A Walker,1 Shinil K Shah,1,2 Erik B Wilson11Department of Surgery, University of Texas Medical School at Houston, Houston, TX, USA; 2Michael E DeBakey Institute for Comparative Cardiovascular Science and Biomedical Devices, Texas A&M University, College Station, TX, USAIntroduction: Novel trocar closure devices using subperitoneal anchor placement avoid the need for a closed loop suture, and could allow faster trocar site closure with less risk derived from less instrument penetration into the abdominal cavity while decreasing fascial ischemia and tension. We completed a series of animal experiments to compare the Carter-Thomason® suture closure device and neoClose® AnchorGuide device in order to evaluate device safety, efficacy, and ease of utilization.Methods: A porcine model was utilized where 12 mm port sites were closed with either the Carter-Thomason® device or neoClose® AnchorGuide device. Animals were sacrificed at 14 and 56 days after trocar site closure followed by macroscopic and microscopic wound examination. A second group of animals underwent video analysis to evaluate the time required for fascial closure as well as depth of needle passage into the abdomen.Results: All animals survived to the endpoints (14 and 56 days without mortality or trocar site hernia. A trend towards decreased closure times was identified when using the neoClose® device (t=18.5±2.3 seconds compared to closure with the Carter-Thomason® device (t=32.0±8.9 seconds (P=0.153. A significant decrease in the depth of needle penetration was seen with the neoClose® device (t=31.22±1.45 mm compared to closure with the Carter-Thomason device (t=51.0±3.1 mm (P<0.001. Microscopic analysis showed subperitoneal anchor location at 56 days with minimal fibrosis (neoClose® device compared to nearly complete suture degradation with deep intramuscular location (Carter-Thomason device.Conclusion: Novel trocar closure devices could offer decreased deployment

  2. CLOSURE DEVICE

    Science.gov (United States)

    Linzell, S.M.; Dorcy, D.J.

    1958-08-26

    A quick opening type of stuffing box employing two banks of rotatable shoes, each of which has a caraming action that forces a neoprene sealing surface against a pipe or rod where it passes through a wall is presented. A ring having a handle or wrench attached is placed eccentric to and between the two banks of shoes. Head bolts from the shoes fit into slots in this ring, which are so arranged that when the ring is rotated a quarter turn in one direction the shoes are thrust inwardly to cramp the neopnrene about the pipe, malting a tight seal. Moving the ring in the reverse direction moves the shoes outwardly and frees the pipe which then may be readily removed from the stuffing box. This device has particular application as a closure for the end of a coolant tube of a neutronic reactor.

  3. Arthroscopic techniques in minimally invasive spine surgery: closure of the lumbar fascia: surgical technique.

    Science.gov (United States)

    Tumialán, Luis M; Ponton, Ryan; Riccio, Anthony I

    2011-04-01

    The constrained working area in minimally invasive exposures of the spine may limit the capacity to effectively close the lumbar fascia, especially in patients with elevated body mass indexes. The working channel in these cases may have a diameter as narrow as 14 mm and a length up to 9 cm. Under these circumstances, the use of a conventional needle driver and a curved needle becomes suboptimal for closures of the fascia. To demonstrate the utility of an arthroscopic suture passer for closure of the lumbar fascia in such approaches. A flexible suture passer, typically used in arthroscopic rotator cuff repair surgery, was used through a minimally invasive portal for fascial closure after minimally invasive lumbar spine procedures. The use of an arthroscopic suture passer precludes the need for rotation of a curved needle in a constrained working area. Deploying a nitinol needle through an arc delivers the suture through the fascia, thereby facilitating closure. Satisfactory lumbar fascia closures were achieved in 18 patients with elevated body mass indexes. Application of existing technology in other surgical specialties may address the shortcomings of current techniques in minimally invasive approaches to the spine. The use of a flexible arthroscopic suture passer is one example in which current technology in one discipline may be applied to minimally invasive approaches. Increasing the awareness of techniques and instruments in other surgical disciplines may expand the armamentarium of the minimally invasive spine surgeon.

  4. An innovative method to evaluate the suture compliance in sealing the surgical wound lips

    Science.gov (United States)

    Saleh, Farid; Palmieri, Beniamino; Lodi, Danielle; Al-Sebeih, Khalid

    2008-01-01

    Background and aim: The increasing number of surgical procedures performed with local anesthesia, followed by immediate patient discharge from the hospital, emphasizes the need for a tight waterproof suture that is capable of maintaining its tensile strength in the postoperative phase when the wound tumescence, edema due to the anesthetic drug, and surgical trauma disappear. Moreover, the issue of having an accurate surgical wound closure is very relevant in vivo in order to prevent hemorrhage and exogenous microbial infections. This study aimed at designing a new a lab technique that could be used for evaluating the best surgical material. Using such a technique, we compared the wound-lip-sealing properties of three commonly-used suture threads, namely polyurethane, polypropylene, and polyamide. Materials and methods: The mechanical properties of same-size suture threads made from polyurethane, polypropylene, and polyamide, were compared in order to define the one that possess the best elastic properties by being able to counteract the tension-relaxation process in the first 12 hours following surgery. The tension holding capacity of the suture materials was measured in both in vivo and in vitro experiments. The surface area of the scar associated with the three different suture threads was measured and compared, and the permeability of the three different suture threads was assessed at 0 minute, 2 minute, 4 minute, 6 minute, and 8 minute- interval. Results: Results showed that polyurethane suture threads had significantly (P suture threads. Moreover, polyurethane suture threads were significantly (P suture thread types (polypropylene and polyamide). This impermeability was also associated with a tighter wound-lip-sealing ability, and with significantly (P suturing. This always raises the question about which suture to use to avoid the above problems. This study provides evidence that the new technique developed in our lab could be used to compare the wound

  5. Comparison of different bronchial closure techniques following pneumonectomy in dogs.

    Science.gov (United States)

    Salci, Hakan; Bayram, A Sami; Ozyigit, Ozgur; Gebitekin, Cengiz; Gorgul, O Sacit

    2007-12-01

    The comparison of the histologic healing and bronchopleural fistula (BPF) complications encountered with three different BS closure techniques (manual suture, stapler and manual suture plus tissue flab) after pneumonectomy in dogs was investigated for a one-month period. The dogs were separated into two groups: group I (GI) (n = 9) and group II (GII) (n = 9). Right and left pneumonectomies were performed on the animals in GI and GII, respectively. Each group was further divided into three subgroups according to BS closure technique: subgroup I (SGI) (n = 3), manual suture; subgroup II (SGII) (n = 3), stapler; and subgroup III (SGIII) (n = 3), manual suture plus tissue flab. The dogs were sacrificed after one month of observation, and the bronchial stumps were removed for histological examination. The complications observed during a one-month period following pneumonectomy in nine dogs (n = 9) were: BPF (n = 5), peri-operative cardiac arrest (n = 1), post-operative respiratory arrest (n = 1), post-operative cardiac failure (n = 1) and cardio-pulmonary failure (n = 1). Histological healing was classified as complete or incomplete healing. Histological healing and BPF complications in the subgroups were analyzed statistically. There was no significant difference in histological healing between SGI and SGIII (p = 1.00; p > 0.05), nor between SGII and SGIII (p = 1.00; p > 0.05). Similarly, no significant difference was observed between the subgroups in terms of BPF (p = 0.945; p > 0.05). The results of the statistical analysis indicated that manual suture, stapler or manual suture plus tissue flab could be alternative methods for BS closure following pneumonectomy in dogs.

  6. Wound closure and tissue adhesives in clear corneal incision cataract surgery.

    Science.gov (United States)

    Tong, Amy Y; Gupta, Preeya K; Kim, Terry

    2018-01-01

    Achieving secure wound closure in clear corneal incision cataract surgery remains highly desired for its role in reducing infection risk and leak-related complications, including hypotony, corneal edema, and lens dislocation. Although classic techniques of stromal hydration or wound suturing represent traditional approaches, the introduction of newer and more effective ocular surface adhesives has increased the options that are available. This review aims to provide an update on the peer-reviewed literature regarding wound closure and the currently available and investigational tissue adhesives used to seal clear corneal incisions in cataract surgery. Stromal hydration and sutured closure of clear corneal incisions remain viable options for wound closure. Wound sealants, particularly polyethylene glycol (PEG)-based hydrogels, have been found to provide watertight wound seal with less foreign-body sensation and surgically induced astigmatism compared with sutures, and less adverse effects and greater ease of use compared with cyanoacrylate and fibrin glues. Stromal hydration, sutured closure, and use of a corneal adhesive are all wound closure options for clear corneal incisions. Of the currently available tissue adhesives, PEG hydrogel sealants have become the most widely accepted, with an improved side-effect and biocompatibility profile.

  7. Application analysis on different suture of scleral flap in trabeculectomy

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2014-05-01

    Full Text Available AIM: To research the application of scleral flap suture in trabeculectomy. METHODS: Totally 114 primary angle-closure glaucoma patients, aged from 36-72 years old, were selected as the objects, and randomly divided into research group and control group. The two groups received different administration methods. Traditional sewing method of sclera flap was used in research group and improved sewing method of sclera flap was used in control group. RESULTS: There was statistical differences between postoperative intraocular pressure of the patients in the observation group and the control group after 1d; 2wk; 1, 3mo(PPP>0.05.CONCLUSION: It is safe and effective that the improved sewing method of sclera flap for trabeculectomy of acute angle-closure glaucoma, and it is a better method to avoid the occurrence of shallow anterior chamber than the traditional sewing method in the early stage after operation.

  8. Use of a Purse-String Suture to Reduce Skin Graft Requirements.

    Science.gov (United States)

    McCue, Jonathan; Kalliainen, Loree K

    2018-02-01

    When a wound cannot be closed in a linear fashion and either a local flap or skin graft is needed, a purse-string suture can be a useful adjunct to wound closure. Local tissue architecture is maintained in cases where clear surgical margins have not been achieved at the time of extirpative skin cancer surgery. We hypothesized that this technique could be applied to a range of wound sizes and locations to avoid or reduce the need for skin grafting. We applied a non-absorbable purse-string suture to wounds in 18 patients over a 15-month period and measured the defect size before and after application of the suture intraoperatively. Residual defects were covered with full- or split-thickness skin grafts. Postoperative wound area, scar hypertrophy, partial graft loss and dehiscence following suture removal were additional outcomes. Ten patients achieved primary wound closure with the purse-string suture, while additional skin grafting was required in eight patients. Wounds closed primarily did not re-expand. Skin-grafted subjects had a 53.8% intraoperative wound area reduction but the skin grafts expanded during recovery, and ultimate reduction diminished to 11% on late follow-up. Wounds accounting for this late re-expansion were located on the extremities. Purse-string sutures are helpful for wound closure in wounds that cannot be closed primarily. They can decrease the size of a skin graft if the wound cannot be closed completely. Wound re-expansion, particularly in extremity defects, may occur following early removal of the tension-bearing purse string.

  9. [A case of intractable fistula after low anterior resection repaired by transsacral direct suture].

    Science.gov (United States)

    Yamada, Takanobu; Kodato, Takashi; Shirai, Junya; Kamiya, Mariko; Sujishi, Ken; Kumazu, Yuta; Sugano, Nobuhiro; Hatori, Shinsuke; Osaragi, Tomohiko; Yoneyama, Katsuya; Kasahara, Akio; Rino, Yasushi; Masuda, Munetaka; Yamamoto, Yuji

    2014-11-01

    We report a case of an intractable fistula repaired by transsacral direct suture. A 65-year-old man underwent low anterior resection for rectal cancer. He subsequently underwent ileostomy due to anastomosis leakage. The fistula of the anastomosis persisted 3 months after surgery. He underwent surgery to repair the fistula using a transsacral approach. After removing the coccyx, the fistula in the postrectal space was exposed directly. The presence of the fistula was confirmed by an air leak test and was closed by direct suture. After 33 days, the patient underwent ileostomy closure.

  10. A Pentagram Suture Technique for Closing Tumor Resection Sites in the Face.

    Science.gov (United States)

    Matsumine, Hajime; Takeuchi, Masaki; Mori, Satoko; Sakurai, Hiroyuki

    2015-08-01

    Resection of facial skin tumors aims to remove the tumors completely and make the surgical scar unnoticeable as much as possible. By improving the purse string suture method, we developed a new pentagram suture technique that enables simple and safe suturing of small to large defects with early satisfactory esthetic outcomes. The surgical outcomes of a case series were examined in this report. As in drawing a unicursal star, 5 suture sites were marked at specific intervals around the defect area. A needle with 5-0 polydioxanone suture was passed from the subcutaneous tissue to the superficial dermal layer at one site and then from the superficial dermal layer to the subcutaneous layer at the next site, and the process was repeated until the pentagram was complete. When apposition was not tight enough, a couple of external stitches were added using 6-0 nylon suture. In 13 patients (16 benign or malignant tumors; mean age, 51.1 years) with a mean tumor size of 10.1 ± 5.2 mm and postoperative skin defect diameter of 12.1 ± 8.2 mm, closure did not result in high tension on the suture, and there was reduced mechanical stress at the wound margin. Surgical outcomes were good esthetically at 6 months after surgery without keloid formation or scar contracture. None of the patients had postoperative pain, infection, or tumor recurrence. This simple alternative method for the closure of facial skin defects after skin tumor excision could be performed easily and provided satisfactory surgical outcomes.

  11. Two year follow-up of astigmatism after phacoemulsification with adjusted and unadjusted sutured versus sutureless 5.2 mm superior scleral incisions.

    Science.gov (United States)

    Lyhne, N; Corydon, L

    1998-12-01

    To evaluate changes in astigmatism 6 months to 2 years after 5.2 mm superior scleral incision phacoemulsification using 3 closures. Department of Ophthalmology, Vejle Hospital, Vejle, Denmark. This long-term follow-up study included 75 consecutive phacoemulsification patients who were randomly allocated to 1 of 3 incision closures: 1 intraoperatively adjusted cross suture, 1 unadjusted cross suture, no suture. Postoperative astigmatism after 1 and 2 years was evaluated by keratometric cylinder, induced astigmatism (Naeser's polar values), induced cylinder (Jaffe's vector analysis), and vector decomposition (Olsen). The data were compared with 1 week values. In the previous study, median astigmatism after 6 months was similar in all 3 groups, but only the sutureless group showed early stability. Significant against-the-rule (ATR) changes were seen in the sutured cases (P suture group exhibited stability after 6 months, while the unadjusted-suture group showed a further tendency to change ATR. At 2 years, median ranges of astigmatism were -0.49 to -0.90 diopter (D) (Naeser), 0.77 to 1.02 D (Jaffe), and 96% to 98% ATR (Olsen). The intergroup differences were not statistically significant. Two year follow-up confirmed that sutureless closure led to early astigmatism stability. Using a suture prolonged the postoperative period of astigmatism instability, and if used without intraoperative adjustment, a tendency toward a less predictable outcome persisted after 2 years.

  12. Biomechanical properties of feline ventral abdominal wall and celiotomy closure techniques.

    Science.gov (United States)

    Reina Rodriguez, Fernando S; Buckley, Conor T; Milgram, Joshua; Kirby, Barbara M

    2017-11-18

    To compare biomechanical properties and mechanism of failure of 3 regions of ventral abdominal wall in cats by using 2 suture materials, 2 suture bite-to-stitch intervals (SBSI), and full-thickness versus fascia-only closure. Randomized, cadaveric, ex vivo mechanical testing. 16 adult cat cadavers, 3 samples per cat. Three regions of ventral abdominal wall were mechanically tested (N = 48 samples). Preumbilical, umbilical (U), and postumbilical (POU) regions were harvested by using a template. The thickness of the linea alba was recorded. Six samples without celiotomy served as controls. Twenty-eight samples were randomized to SBSI (2 × 2 or 5 × 5 mm) and suture material (3-0 polyglactin 910 or 3-0 polydioxanone) for simple continuous celiotomy closure. Fourteen samples were randomized to full-thickness or fascia-only closure. Samples were tested by linear distraction; tensile strength and mechanism of failure were recorded. Effects of body weight, thickness of linea alba, anatomic region, SBSI, type of closure, and suture material were evaluated by mixed model linear analysis. Load to failure was compared between males and females, full-thickness and fascia-only closure by independent t test, with P < .05 considered statistically significant. The POU region achieved lower loads to failure. Load to failure was greater in males compared with females. No difference was detected between full-thickness and fascia-only closure. Failure most commonly occurred by tearing of suture through tissues. Tissue failure with suture line loosening occurred mainly in the 5 × 5-mm SBSI group. The POU region is biomechanically weak and may therefore be predisposed to incisional herniation. © 2017 The Authors Veterinary Surgery published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Surgeons.

  13. [Induced astigmatism in extracapsular cataract extraction with tunnel incision and various wound closures].

    Science.gov (United States)

    Häberle, H; Anders, N; Pham, D T; Wollensak, J

    1995-09-01

    For planned extracapsular cataract extraction the no-stitch technique with 11-mm tunnel width has been well established. Four modifications of wound closure were performed to further reduce surgically induced astigmatism. In this prospective study we controlled 250 eyes of 250 consecutive patients 4 months after surgery with four different wound constructions: sutureless wound closure (n = 70), singular perpendicular suture (n = 100), cross suture (n = 40) in 12 o'clock position or sutureless wound closure in temporal position (n = 40). Surgically 'Induced Astigmatism' was for eyes with preoperative 'With the Rule Astigmatism' (vs Against the Rule astigmatism), operation in 12 o'clock position and sutureless wound closure 2.22 +/- 0.77 D (1.66 +/- 0.94 D), with perpendicular suture 1.66 +/- 0.93 D (1.24 +/- 0.82 D), and with cross suture 1.47 +/- 0.96 D (0.9 +/- 1.13 D). Temporal incision was only performed in preoperative 'Against-the-Rule-Astigmatism' eyes and resulted in 0.6 D of 'Induced Astigmatism'. Preoperative average astigmatism was 0.86 +/- 0.68 D (1.01 +/- 0.95 D). For preoperative 'With the Rule Astigmatism', operation in 12 o'clock position and singular perpendicular suture and for 'Against the Rule Astigmatism' (especially > 1.5 D) temporal incision is recommended.

  14. Bacterial Biofilms on Implanted Suture Material Are a Cause of Surgical Site Infection

    Science.gov (United States)

    Nistico, Laura; Tower, Irene; Lasko, Leslie-Ann; Stoodley, Paul

    2014-01-01

    Abstract Background: Surgical site infection (SSI) has been estimated to occur in up to 5% of all procedures, accounting for up to 0.5% of all hospital costs. Bacterial biofilms residing on implanted foreign bodies have been implicated as contributing or causative factors in a wide variety of infectious scenarios, but little consideration has been given to the potential for implanted, submerged suture material to act as a host for biofilm and thus serve as a nidus of infection. Methods: We report a series of 15 patients who underwent open Roux-en-Y gastric bypass (with musculofascial closure with permanent, multifilament sutures) who developed longstanding and refractory SSIs in the abdominal wall. Explanted suture material at subsequent exploration was examined for biofilm with confocal laser-scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). Results: All 15 patients at re-exploration were found to have gross evidence of a “slimy” matrix or dense reactive granulation tissue localized to the implanted sutures. Confocal laser-scanning microscopy revealed abundant biofilm present on all sutures examined; FISH was able to identify the presence of specific pathogens in the biofilm. Complete removal of the foreign bodies (and attendant biofilms) resulted in all cases in cure of the SSI. Conclusion: Bacterial biofilms on implanted suture material can manifest as persistent surgical site infections that require complete removal of the underlying foreign body substrata for resolution. PMID:24833403

  15. The effect of suture characteristics on short-term morbidity after vaginal prolapse surgery.

    Science.gov (United States)

    Mizon, G; Duckett, J

    2015-01-01

    Previous studies suggest that larger sutures increase the risk of complications after prolapse surgery. This study aimed to assess whether multifilament sutures increased complications compared with monofilament sutures. A series of 100 women with 2/0 multifilament suture were matched by operation to a previous cohort when a size 2/0 monofilament suture was used. Offensive vaginal discharge was more common in the multifilament than in the monofilament group (24% vs. 12%; p = 0.04). However, there was no increased requirement to seek advice from a health professional (33% vs. 25%; p = 0.27) or to require antibiotics. Vaginal bleeding (10% vs. 5%; p = 0.28) and urinary infection (2% vs. 5%; p = 0.44) were statistically no more common in the multifilament 2/0 compared with the monofilament 2/0 group. Multifilament sutures used for closure of the vaginal skin are associated with a clinically non-significant higher incidence of vaginal discharge in the early post-operative period.

  16. Current practice of abdominal wall closure in elective surgery – Is there any consensus?

    Directory of Open Access Journals (Sweden)

    Ridwelski Karsten

    2009-05-01

    Full Text Available Abstract Background Development of incisional hernia after open abdominal surgery remains a major cause of post-operative morbidity. The aim of this study was to determine the current practice of surgeons in terms of access to and closure of the abdominal cavity in elective open surgery. Methods Twelve surgical departments of the INSECT-Trial group documented the following variables for 50 consecutive patients undergoing abdominal surgery: fascial closure techniques, applied suture materials, application of subcutaneous sutures, subcutaneous drains, methods for skin closure. Descriptive analysis was performed and consensus of treatment variables was categorized into four levels: Strong consensus >95%, consensus 75–95%, overall agreement 50–75%, no consensus Results 157 out of 599 patients were eligible for analysis (85 (54% midline, 54 (35% transverse incisions. After midline incisions the fascia was closed continuously in 55 patients (65%, using slowly absorbable (n = 47, 55%, braided (n = 32, 38% sutures with a strength of 1 (n = 48, 57%. In the transverse setting the fascia was closed continuously in 39 patients (72% with slowly absorbable (n = 22, 41% braided sutures (n = 27, 50% with a strength of 1 (n = 30, 56%. Conclusion In the present evaluation midline incision was the most frequently applied access in elective open abdominal surgery. None of the treatments for abdominal wall closure (except skin closure in the midline group is performed on a consensus level.

  17. Cataract surgery and methods of wound closure: a review

    Directory of Open Access Journals (Sweden)

    Matossian C

    2015-05-01

    Full Text Available Cynthia Matossian,1 Sarah Makari,2 Richard Potvin2 1Matossian Eye Associates, Pennington, NJ, 2Science in Vision, Akron, NY, USA Abstract: Clear corneal incisions are routinely used in cataract surgery, but watertight wound closure may not always be achieved, which can increase the risk for anterior chamber fluid egress or ocular surface fluid ingress. A new US Food and Drug Administration-approved ocular sealant appears to have good efficacy in sealing clear corneal incisions; its use may be indicated when wound integrity is in question. Keywords: clear corneal incisions, wound closure, sealant, suture, stromal hydration, cataract surgery

  18. Bilateral Anterior Rectus Sheath Turnover Flap for Abdominal Closure

    Directory of Open Access Journals (Sweden)

    Bulent Kaya

    2013-10-01

    Full Text Available The management of abdominal wall hernias with tissue loss is a difficult subject.Several surgical techniques have been used in the treatment. Sometimes closure of the abdomen with primary sutures may be impossible. Dual meshes, component separation technique, usculofascial flaps can be used for closure of the abdomen.In this case report a patient with complex abdominal wall hernia was presented.The abdomen was successfully closed with anterior rectus sheath turnover flap.We discussed this surgical technique with literature review.

  19. Comparison of elastic versus rigid suture material for peripheral sutures in tendon repair.

    Science.gov (United States)

    Nozaki, Kenji; Mori, Ryuji; Ryoke, Koji; Uchio, Yuji

    2012-06-01

    For secure tendon repair, while core suture materials have been previously investigated, the optimum material for peripheral sutures remains unclear. Transected bovine gastrocnemius tendons were repaired by 2-strand side-locking loop technique using no.2 braided polyblend polyethylene thread for the core suture. Then, 8-strand peripheral cross-stitches were added using either 2-0 rigid sutures (braided polyblend polyethylene) or USP 2-0-sized elastic sutures (nylon). The holding area of each peripheral suture was set at either 3 × 1 mm (shallow holding) or 6 × 2 mm (deep holding). Therefore, 4 groups were compared (the shallow-rigid, deep-rigid, shallow-elastic, and deep-elastic groups). The gap formation, ultimate tensile strength, and suture migration state were measured after 500 cyclic loadings (from 10 to 200 N). The shallow-rigid group had inferior outcomes compared to the other groups. Although the deep-rigid group had the smallest gap and highest ultimate strength, all peripheral sutures had failure prior to core suture rupture. The two elastic groups showed no significant differences, irrespective of the size of the holding area. Suture migration did not occur in the two elastic groups until the ultimate strength was reached and the core suture ruptured. Depending on the suturing method, rigid suture material may not be appropriate for peripheral sutures, when accompanying rigid core suture material. If peripheral sutures can be made with accurate deep holding, rigid suture material will provide favorable outcome. However, in other cases, elastic suture material is considered best for supporting a rigid core suture, as elasticity is another important factor for peripheral sutures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Suture granuloma mimicking a recurrent sacro-coccygeal pilonidal sinus after Limberg flap.

    Science.gov (United States)

    Ardelt, Michael; Dittmar, Yves; Schulz, Birte; Rauchfuss, Falk; Scheuerlein, Hubert; Settmacher, Utz

    2014-12-01

    Sacro-coccygeal pilonidal sinus disease is classified as an asymptomatic, acutely abscess-forming or chronic subcutaneous inflammation in the sacro-coccygeal region featuring characteristic pits in the bottom cleft. Due to high rates of recurrence, two flap techniques have been established in the course of the past three decades. One of them is the Karydakis operation, the other option is a rotation flap named Limberg procedure. We report about a case of suture granuloma in the area of a Limberg flap after recurrent pilonidal sinus with extrusion of the suture material, thus mimicking recurrence. In case of recurrent pilonidal sinus following plastic coverage or primary closure, respectively, the differential diagnosis of suture granuloma should be considered. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. Full closure strategic analysis.

    Science.gov (United States)

    2014-07-01

    The full closure strategic analysis was conducted to create a decision process whereby full roadway : closures for construction and maintenance activities can be evaluated and approved or denied by CDOT : Traffic personnel. The study reviewed current...

  2. The influence of suture material on the strength of horizontal mattress suture configuration for meniscus repair.

    Science.gov (United States)

    Hapa, Onur; Akşahin, Ertuğrul; Erduran, Mehmet; Davul, Serkan; Havitçioğlu, Hasan; LaPrade, Robert F; Bozdağ, Ergun; Sünbüloğlu, Emin

    2013-12-01

    Comparison of the mechanical characteristics of meniscal repair fixation using horizontal sutures and six different sutures under submaximal cyclic and load to failure test conditions may aid physicians in selecting a suture type. A 2-cm long anteroposterior vertical longitudinal incision was created in six groups of bovine medial menisci. Lesions were repaired using a No. 2 suture either composed of polyester or polyester and ultra high-molecular weight polyethylene (UHMWPE), or UHMWPE and polydioxanone or pure UHMWPE. Endpoints included ultimate failure load (N), pull-out stiffness (N/mm), pull-out displacement (mm), cyclic displacement (mm) after 100cycles, after 500cycles, and mode of failure. Polyester suture had lower ultimate load than all groups except the suture composed of polyester and UHMWPE (Psuture had higher ultimate failure load than sutures composed of either polyester or polyester plus UHMWPE (Psuture cutting through the meniscus for the groups except for polyester suture which failed by suture rupture. Under cyclic loading conditions in bovine meniscus, braided polyester suture fixation provided lower initial fixation strength than fixation with various high strength sutures composed of pure UHMWPE or a combination of absorbable monofilament polydioxanone and UHMWPE, except for combination of polyester and UHMWPE sutures. Present study does not support the usage of the braided polyester sutures instead of high strength sutures composed either partially or totally of ultra-high molecular weight polyethylene for the horizontal suture configuration of meniscus repair. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. The Requirement of Sutures to Close Intercostal Drains Site Wounds in Thoracic Surgery.

    Science.gov (United States)

    Smelt, Jeremy L C; Simon, Natalie; Veres, Lukacs; Harrison-Phipps, Karen; Bille, Andrea

    2018-02-01

    Chest drains are used routinely in thoracic surgery. Often a pursestring or mattress suture is used to facilitate closure of the defect on removal of the drain. This stitch can cause an unsightly scar, increase drain removal pain, and necessitate that the patient attend a community health care center to have this removed. The objective of this study was to assess whether this stitch is necessary in modern thoracic surgical practice. Data from a single surgeon's practice were collected over an 18-month period. During this time, all patients who underwent both emergency and elective thoracic surgery who had at least one postoperative chest drain of 28F or above inserted were included in the study. The surgeon did not routinely use a suture to close the drain site. In all, 312 patients underwent thoracic surgery during the 18-month period. Each patient had a range of 1 to 3 drains inserted of a size between 28F and 32F. No patients had drain sutures for closure of the drain site. Four patients had pneumothoraces after drain removal requiring further chest drain insertion. Five patients had superficial drain site infections. A single patient had to have a suture inserted at a local hospital owing to leakage from the drain site. The use of pursestring sutures in thoracic surgery is an outdated practice that causes not only unsightly scars but is also associated with increased pain. Furthermore, these unnecessary pursestring sutures place a burden on the patient and health care system to have them removed. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Arachnoid Membrane Suturing for Prevention of Subdural Fluid Collection in Extracranial-intracranial Bypass Surgery.

    Science.gov (United States)

    Kim, Gun Woo; Joo, Sung Pil; Kim, Tae Sun; Moon, Hyung Sik; Jang, Jae Won; Seo, Bo Ra; Lee, Jung Kil; Kim, Jae Hyoo; Kim, Soo Han

    2014-06-01

    Water-tight closure of the dura in extracranial-intracranial (EC-IC) bypass is impossible because the superficial temporal artery (STA) must run through the dural defect. Consequently, subdural hygroma and subcutaneous cerebrospinal fluid (CSF) collection frequently occur postoperatively. To reduce these complications, we prospectively performed suturing of the arachnoid membrane after STA-middle cerebral artery (STA-MCA) and evaluated the clinical usefulness. Between Mar. 2005 and Oct. 2010, extracranial-intracranial arterial bypass (EIAB) with/without encephalo-myo-synangiosis was performed in 88 cases (male : female = 53 : 35). As a control group, 51 patients (57 sides) underwent conventional bypass surgery without closure of the arachnoid membrane. Postoperative computed tomography (CT) scan was performed twice in three days and seven days later, respectively, for evaluation of the presence of subdural fluid collection and other mass lesions. The surgical result was excellent, with no newly developing ischemic event until recent follow-up. The additional time needed for arachnoid suture was five to ten minutes, when three to eight sutures were required. Post-operative subdural fluid collection was not seen on follow-up computed tomography scans in all patients. Arachnoid suturing is simple, safe, and effective for prevention of subdural fluid collection in EC-IC bypass surgery, especially the vulnerable ischemic hemisphere.

  5. Effect of Unshaven Hair with Absorbable Sutures and Early Postoperative Shampoo on Cranial Surgery Site Infection.

    Science.gov (United States)

    Oh, Won-Oak; Yeom, Insun; Kim, Dong-Seok; Park, Eun-Kyung; Shim, Kyu-Won

    2018-01-01

    Cranial surgical site infection is a significant cause of morbidity and mortality in hospitals. Preoperative hair shaving for cranial neurosurgical procedures is performed traditionally in an attempt to protect patients against complications from infections at cranial surgical sites. However, preoperative shaving of surgical incision sites using traditional surgical blades without properly washing the head after surgery can cause infections at surgical sites. Therefore, a rapid protocol in which the scalp remains unshaven and absorbable sutures are used for scalp closure with early postoperative shampooing is examined in this study. A retrospective comparative study was conducted from January 2008 to December 2012. A total of 2,641 patients who underwent unshaven cranial surgery with absorbable sutures for scalp closure were enrolled in this study. Data of 1,882 patients who underwent surgery with the traditional protocol from January 2005 to December 2007 were also analyzed for comparison. Of 2,641 patients who underwent cranial surgery with the rapid protocol, all but 2 (0.07%) patients experienced satisfactory wound healing. Of 1,882 patients who underwent cranial surgery with the traditional protocol, 3 patients (0.15%) had infections. Each infection occurred at the superficial incisional surgical site. Unshaven cranial surgery using absorbable sutures for scalp closure with early postoperative shampooing is safe and effective in the cranial neurosurgery setting. This protocol has a positive psychological effect. It can help patients accept neurosurgical procedures and improve their self-image after the operation. © 2017 S. Karger AG, Basel.

  6. Closure The Definitive Guide

    CERN Document Server

    Bolin, Michael

    2010-01-01

    If you're ready to use Closure to build rich web applications with JavaScript, this hands-on guide has precisely what you need to learn this suite of tools in depth. Closure makes it easy for experienced JavaScript developers to write and maintain large and complex codebases -- as Google has demonstrated by using Closure with Gmail, Google Docs, and Google Maps. Author and Closure contributor Michael Bolin has included numerous code examples and best practices, as well as valuable information not available publicly until now. You'll learn all about Closure's Library, Compiler, Templates, tes

  7. Viable adhered Staphylococcus aureus highly reduced on novel antimicrobial sutures using chlorhexidine and octenidine to avoid surgical site infection (SSI)

    Science.gov (United States)

    Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; von Deimling, Constantin; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias

    2018-01-01

    Background Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. Objectives This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. Methods As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Results Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on

  8. Viable adhered Staphylococcus aureus highly reduced on novel antimicrobial sutures using chlorhexidine and octenidine to avoid surgical site infection (SSI).

    Science.gov (United States)

    Obermeier, Andreas; Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; Deimling, Constantin von; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias; Burgkart, Rainer; von Eisenhart-Rothe, Rüdiger

    2018-01-01

    Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for

  9. Patrones de cierre velofaringeo: Estudio comparativo entre población sana y pacientes con paladar hendido Patterns of velopharyngeal closure: comparative study between healthy population and patients with cleft palate

    Directory of Open Access Journals (Sweden)

    J.R. Prada Madrid

    2010-12-01

    Full Text Available El propósito de este estudio es corroborar los patrones de cierre velofaríngeo descritos en la literatura y su frecuencia de aparición en una muestra no probabilística de voluntarios sanos, así como comparar estos hallazgos con los obtenidos en pacientes con paladar fisurado reparado quirúrgicamente. Diseñamos para ello un estudio descriptivo de corte transversal. Las valoraciones se realizaron en un hospital de cuarto nivel y en el Centro de Rehabilitación para Niños con Labio y Paladar Fisurado (FISULAB, en santa Fe de Bogotá (Colombia. Participaron en el estudio 100 voluntarios sanos estudiantes universitarios y 82 pacientes con paladar hendido reparado quirúrgicamente. Realizamos videonasofaringoscopia para determinar los patrones de cierre velofaríngeo presentes y su frecuencia de aparición. El análisis estadístico se realizó utilizando el Chi², encontrando que no existe diferencia en la frecuencia de presentación de los patrones de cierre entre los voluntarios sanos y los pacientes con paladar hendido. En pacientes sanos encontramos con mayor frecuencia el patrón circular (56% de la muestra, seguido por el coronal (29 % y el circular con rodete de Passavant (15 %. En los pacientes con paladar hendido, igualmente prevaleció el patrón circular (39.02 %, seguido del patrón coronal (24.39 % y el patrón circular con rodete de Passavant (19.51 %. En ninguno de los 2 grupos encontramos el patrón sagital. En conclusión, corroboramos la presentación de 3 de los 4 patrones de cierre velofaríngeo descritos en la literatura (circular, coronal, circular con rodete de Passavant, sin que existiera una diferencia estadística en la frecuencia de presentación de los patrones de cierre velofaríngeo entre los voluntarios sanos y los pacientes con hendidura palatina. No corroboramos la presentación del patrón sagital.The purpose of this study is to define the patterns of velopharyngeal closure described in the literature, and

  10. Rash with DERMABOND PRINEO Skin Closure System Use in Bilateral Reduction Mammoplasty: A Case Series

    Directory of Open Access Journals (Sweden)

    R. W. Knackstedt

    2015-01-01

    Full Text Available Background. Bilateral reduction mammoplasty is a common plastic surgery procedure that can be complicated by unfavorable scar formation along incision sites. Surgical adhesives can be utilized as an alternative or as an adjunct to conventional suture closures to help achieve good wound tension and provide an adequate barrier with excellent cosmesis. The recently introduced DERMABOND PRINEO Skin Closure System Skin Closure System combines the skin adhesive 2-octyl cyanoacrylate with a self-adhering polyester-based mesh. Proposed benefits of wound closure with DERMABOND PRINEO Skin Closure System, used with or without sutures, include its watertight seal, easy removal, microbial barrier, even distribution of tension, and reduction in wound closure time. Although allergic reactions to 2-octyl cyanoacrylate have been reported, few allergic reactions to DERMABOND PRINEO Skin Closure System have been noted in the literature. This case series describes three patients who experienced an allergic reaction to DERMABOND PRINEO Skin Closure System after undergoing elective bilateral reduction mammoplasties at our institution to further explore this topic. Methods. Retrospective chart review of bilateral reduction mammoplasty patients who received DERMABOND PRINEO Skin Closure System dressing at our institution was performed. Results. Three patients were identified as having a rash in reaction to DERMABOND PRINEO Skin Closure System after bilateral reduction mammoplasty. All three patients required systemic steroid treatment to resolve the rash. One patient was identified as having a prior adhesive reaction. Conclusions. DERMABOND PRINEO Skin Closure System has demonstrated its efficacy in optimizing scar healing and appearance. However, as we demonstrate these three allergic reactions to DERMABOND PRINEO Skin Closure System, caution must be utilized in its usage, namely, in patients with a prior adhesive allergy and in sites where moisture or friction may

  11. Healing study of porcine heart transapical wounds closed using a remote automated suturing technology.

    Science.gov (United States)

    Wilshire, Candice L; Kaufer, James W; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    2013-01-01

    A safe and reliable direct percutaneous approach for transapical access to the left ventricle would be a significant advance toward decreasing the invasiveness of intracardiac interventions. This report presents results from a surviving porcine beating heart model in which transapical access sites were closed using an automated suturing technique ultimately intended for percutaneous use. Through an approved protocol including general anesthesia, the cardiac apex in 10 beating pig hearts was surgically exposed, permitting transapical passage of a 0.035-in guidewire and a 5.5F, 0.9-mL Fogarty balloon catheter. An automated suturing device was passed over the guidewire and the Fogarty onto the transapical access site. Two pledgeted horizontal mattress sutures were simultaneously placed concentrically around the apical access site with a single squeeze of the device's lever. A 25F dilator was passed into the left ventricle over the guidewire and subsequently removed. The sutures were then secured using pledgeted titanium knots. Chest wall and skin incisions were closed. The animals were recovered from anesthesia and resumed a normal diet. Under general anesthesia, the transapical access site of each animal was re-exposed, five at 1-week and five at 2-week intervals. Hemostasis was complete, and all wounds healed well. The evaluation of transapical wound closures in this surviving porcine heart model demonstrates complete hemostasis and excellent healing through the use of this automated remote suturing technology.

  12. Influence of medical students' past experiences and innate dexterity on suturing performance.

    Science.gov (United States)

    Hughes, David T; Forest, Stephen J; Foitl, Rosangela; Chao, Edward

    2014-08-01

    Medical students often cite their ability to excel at technical tasks as justification for choosing surgery as a career path. We sought to investigate how medical students' dexterity skills and past experiences correlated with suturing performance. Sixty-four 3rd-year medical students were surveyed about previous experiences that involved manual dexterity. Technical skills were then measured using a validated test of manual dexterity and subcuticular closure of a pig's foot incision. Spearman's rank correlation coefficients determined correlation between variables. Previous experiences, self-assessment of dexterity, prior suturing, and current interest in surgery did not significantly correlate with manual dexterity or suturing skill scores. Innate manual dexterity score was the only significant correlating factor to suture skill score (Spearman's rank correlation coefficient = .336; P = .007). Innate manual dexterity skills are predictive of initial surgical suturing performance regardless of past student experiences. Interventions aimed at improving early surgical technique should be optimally focused on dexterity training. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Comparative histology of some craniofacial sutures and skull-base synchondroses in non-avian dinosaurs and their extant phylogenetic bracket.

    Science.gov (United States)

    Bailleul, Alida M; Horner, John R

    2016-08-01

    Sutures and synchondroses, the fibrous and cartilaginous articulations found in the skulls of vertebrates, have been studied for many biological applications at the morphological scale. However, little is known about these articulations at the microscopic scale in non-mammalian vertebrates, including extant archosaurs (birds and crocodilians). The major goals of this paper were to: (i) document the microstructure of some sutures and synchondroses through ontogeny in archosaurs; (ii) compare these microstructures with previously published sutural histology (i.e. that of mammals); and (iii) document how these articulations with different morphological degrees of closure (open or obliterated) appear histologically. This was performed with histological analyses of skulls of emus, American alligators, a fossil crocodilian and ornithischian dinosaurs (hadrosaurids, pachycephalosaurids and ceratopsids). Emus and mammals possess a sutural periosteum until sutural fusion, but it disappears rapidly during ontogeny in American alligators. This study identified seven types of sutural mineralized tissues in extant and extinct archosaurs and grouped them into four categories: periosteal tissues; acellular tissues; fibrous tissues; and intratendinous tissues. Due to the presence of a periosteum in their sutures, emus and mammals possess periosteal tissues at their sutural borders. The mineralized sutural tissues of crocodilians and ornithischian dinosaurs are more variable and can also develop via a form of necrosis for acellular tissues and metaplasia for fibrous and intratendinous tissues. It was hypothesized that non-avian dinosaurs, like the American alligator, lacked a sutural periosteum and that their primary mode of ossification involved the direct mineralization of craniofacial sutures (instead of intramembranous ossification found in mammals and birds). However, we keep in mind that a bird-like sutural microstructure might have arisen within non-avian saurichians. While

  14. The role of the sutures in biomechanical dynamic simulation of a macaque cranial finite element model: implications for the evolution of craniofacial form.

    Science.gov (United States)

    Wang, Qian; Wood, Sarah A; Grosse, Ian R; Ross, Callum F; Zapata, Uriel; Byron, Craig D; Wright, Barth W; Strait, David S

    2012-02-01

    The global biomechanical impact of cranial sutures on the face and cranium during dynamic conditions is not well understood. It is hypothesized that sutures act as energy absorbers protecting skulls subjected to dynamic loads. This hypothesis predicts that sutures have a significant impact on global patterns of strain and cranial structural stiffness when analyzed using dynamic simulations; and that this global impact is influenced by suture material properties. In a finite element model developed from a juvenile Rhesus macaque cranium, five different sets of suture material properties for the zygomaticotemporal sutures were tested. The static and dynamic analyses produced similar results in terms of strain patterns and reaction forces, indicating that the zygomaticotemporal sutures have limited impact on global skull mechanics regardless of loading design. Contrary to the functional hypothesis tested in this study, the zygomaticotemporal sutures did not absorb significant amounts of energy during dynamic simulations regardless of loading speed. It is alternatively hypothesized that sutures are mechanically significant only insofar as they are weak points on the cranium that must be shielded from unduly high stresses so as not to disrupt vitally important growth processes. Thus, sutural and overall cranial form in some vertebrates may be optimized to minimize or otherwise modulate sutural stress and strain. Copyright © 2011 Wiley Periodicals, Inc.

  15. Results of vacuum assisted wound closure application.

    Science.gov (United States)

    Atay, Tolga; Burc, Halil; Baykal, Yakup Barbaros; Kirdemir, Vecihi

    2013-08-01

    In recent past, various methods have been used for wound treatment purpose. In this study, we aimed to compare our results established from the vacuum-assisted wound closure method, which has gained popularity day by day, with the literature. A total of 48 patients, who received vacuum-assisted wound closure treatment in our clinic between 2007and 2010, were included in this study. Etiological distribution of the patients was as follows: 32 traumatic, 6 pressure sore, 9 diabetic, and 1 iliac disarticulation. All cases were evaluated in terms of age, gender, etiology, period of treatment, and size of the wound. In the patients studied, 42 were men (87.5 %) and 6 were women (12.5 %). Mean age of the patients was 39.6 years (11-61 years). All of our traumatic patients suffered from open fracture. After the vacuum-assisted wound closure application, wound size reduced by 28.8 %, while the mean area of the surface of the wound was 94.7 cm(2) (13.7-216.3 cm(2)) on average. After the wounds became ready for surgery, 15 of them were treated with split-thickness grafting, 9 of them were treated with secondary suture, 18 of them were treated with full-thickness grafting, and 6 of them were treated with flap. Average period of the application of vacuum-assisted wound closure was 11.6 days (7-15 days). Results of vacuum-assisted wound closure can be regarded as satisfactory when cases are selected properly. This system has three different effect mechanisms. Firstly, it increases local blood flow on the wound bed. Secondly, cell proliferation is triggered following the mechanic stress. Thirdly, vacuum removes the proteases from the environment which obstructs healing. Therefore, it is intended to prepare alive wound bed which is required for subsequent soft tissue reconstructions.

  16. Non-closure of peritoneal surfaces at caesarean section — a ...

    African Journals Online (AJOL)

    Nicky

    2005-06-14

    Jun 14, 2005 ... Caesarean section (CS) is a very common surgical procedure worldwide. Suturing the peritoneal layers ... trend for analgesia requirement and wound infection tended to favour non-closure, while endometritis results were variable. ... operative procedures, assessment of trial quality was limited to allocation ...

  17. A comparison of 2-octyl cyanoacrylate with nylon for wound closure of knee arthroscopy portals.

    Science.gov (United States)

    Imbuldeniya, A M; Rashid, A; Murphy, J P

    2014-09-01

    To compare the cosmetic results, complications and patient satisfaction of 2-octyl cyanoacrylate (Dermabond, Ethicon Inc. Somerville, NJ, USA), a liquid bonding agent, with 3-0 nylon sutures (Ethilon, Ethicon Inc) skin closure in two groups of patients undergoing elective knee arthroscopy at 6 weeks. The retrospective clinical audit recruited patients undergoing knee surgery for the first time between October 2010 and August 2011. The patients were either treated with the liquid bonding agent or nylon sutures. The patients in the bonding agent group were allowed to shower as normal on postoperative day one, while patients in the suture group kept their wounds dry for 2 weeks. Between the two groups (40 patients per group) there was no difference in the cosmetic outcome (p=0.285), patient satisfaction (p=0.29), pain scores (p=0.44) or wound complication rate (pnylon sutures if undergoing the same procedure in the future as they could shower the next day and avoid suture removal. 2-octyl cyanoacrylate is safe to use in the short term in knee arthroscopy providing comparable results to nylon suture closure. Allowing patients to shower the next day appears to cause no adverse effects. The authors would like to state that they do not have any economic or social interest in any of the products used or mentioned. No grant or finance was received for this study, nor any input from other sources.

  18. 'The Closer'-percutaneous vascular suture device: evaluation of safety and performance in neuroangiography

    Energy Technology Data Exchange (ETDEWEB)

    Henk, Christine B. E-mail: christine.henk@univie.ac.at; Grampp, Stephan; Heimberger, Karl; Czerny, Christian; Schindler, Erwin; Mostbeck, Gerhard H

    2003-12-01

    Objective: To evaluate the use of the suture mediated vascular closure device concerning practicability and safety in clinical angiography practice. Material and methods: One hundred and seventeen patients (59 female, 58 male, mean age 40.9{+-}13.4) underwent percutaneous closure of common femoral arterial puncture sites following diagnostic neuroangiography using the suture device 'the Closer' (Perclose Inc., Redwood City, CA, USA). Primary success, early problems (within 24 h) and late complications were evaluated. Complications were graded as minor and severe with or without need of surgical intervention and categorized by type. Parameters such as age, gender, sheath size and number of previous arterial punctures were evaluated with respect to complications. Results: Percutaneous closure was primary successful in 85% (100/117). The overall complication rate was 32% (28% mild n=35, 4% severe n=6, which needed surgical intervention). All but one problem occurred within the first 24 h after the suture. Additional manual compression was necessary in 32 cases (25%). There was no significant difference in age and gender between the groups with and without complications. Sheath size was significantly larger (P<0.01) and numbers of preceding angiograms were significantly higher (P<0.01) in the complications group compared with uncomplicated cases. Conclusion: The evaluated percutaneous vascular suture device is useful in clinical practice but limitations concerning patient selection seem to emerge in order to avoid complications.

  19. Arthroscopic Rotator Cuff Repair With Absorbable Sutures in the Medial-Row Anchors.

    Science.gov (United States)

    Tanaka, Makoto; Hayashida, Kenji; Kobayashi, Atsushi; Kakiuchi, Masaaki

    2015-11-01

    To report the retear rate and retear pattern after double-row arthroscopic rotator cuff repair (DR-ARCR) with the use of absorbable sutures as medial anchor sutures and to address the advantage of the use of absorbable sutures in medial-row anchors. Fifty-seven shoulders (22 male and 35 female patients; mean age, 66.1 years) with complete rotator cuff tears treated with DR-ARCR using absorbable mattress sutures as medial-row anchor sutures were included in the study. They included 35 medium, 17 large, and 5 massive tears. For the medial row, medial anchor sutures were replaced with absorbable mattress sutures. High-strength simple sutures were used for the lateral anchors. We evaluated retear patterns by magnetic resonance imaging examinations performed at 1 month, 3 months, 6 months, and 1 year postoperatively. The clinical conditions of all patients preoperatively and 2 years postoperatively were assessed by the University of California, Los Angeles rating scale and the American Shoulder and Elbow Surgeons shoulder index. A complete retear of the tendon at the footprint was observed in 5 shoulders. Complete discontinuity at the middle of the tendon around the medial-row anchors with a footprint remnant was observed in 1 shoulder. A thinned repaired rotator cuff was observed in 2 shoulders because of a partial retear of the deep layer. The overall retear rate was 14%. From before to after surgery, the University of California, Los Angeles score significantly improved from 18.4 to 32.9 (P sutures as medial-row anchors were 8.8% for complete retears of the tendon at the footprint and 1.7% for complete discontinuity of tendon around the medial-row anchors. This procedure provided a low retear rate around the medial-row anchors. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Tissue reactions of abdominal integuments to surgical sutures in sonography

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2014-03-01

    Full Text Available Classical abdominal surgeries usually require long incisions of the abdominal integuments followed by tight closure with adequate suturing material. Nonabsorbable sutures may cause various reactions, including granuloma reactions, both sterile and inflammatory. The aim of the study was to analyze prospective ultrasound examinations of the abdominal integuments in order to detect tissue reactions to surgical sutures. Material and methods: For 10 years, ultrasound examinations of the abdominal integuments involved the assessment of surgical scars in all patients who underwent open or closed surgeries for various reasons (in total 2254 patients. Ultrasound examinations were performed only with the use of linear probes with the frequency ranging from 7 to 12 MHz. Each scar in the abdominal integuments was scanned in at least two planes. When a lesion was detected, the image was enlarged and the transducer was rotated by approximately 180° in order to capture the dimensions of the granuloma and the most characteristic image of the suture. Moreover, vascularization of the lesion was also assessed with the use of color Doppler mode set to detect the lowest flows. Results: All granulomas (19 lesions, two in one patient created hypoechoic oval or round nodules, were relatively well-circumscribed and their size ranged from 8 × 4 mm to 40 × 14 mm. In the center of the lesion, it was possible to notice a thread that was coiled to various degrees and presented itself as a double, curved hyperechoic line. In 9 out of 19 granulomas, slight peripheral vascularization was observed. The substantial majority of the lesions (n = 15 were in contact with the fascia. In seven patients, compression with the transducer induced known local pain (n = 4 or intensified pain that had already been present (n = 3; all of these granulomas infiltrated the fascia and showed slight peripheral vascularization. Cutaneous fistulae developed in two patients with purulent

  1. Suture slippage in knotless suture anchors as a potential failure mechanism in rotator cuff repair.

    Science.gov (United States)

    Wieser, Karl; Farshad, Mazda; Vlachopoulos, Lazaros; Ruffieux, Kurt; Gerber, Christian; Meyer, Dominik C

    2012-11-01

    To quantify the strength of suture fixation of knotless suture anchors in relation to the anchors' pullout strength and to compare these results with the static friction between different sutures and anchor materials. Suture slippage within the anchor and pullout strength of 4 different knotless suture anchor models were assessed in a bovine bone model. Furthermore, the peak force before onset of slippage of different sutures trapped between increasingly loaded 4-mm rods made of commonly used anchor material (polyetheretherketone, poly-L-lactide acid, metal) was assessed. In all but 1 of the tested anchors, there was a relevantly lower load needed for slippage of the sutures than to pull out the anchor from bone. The mean load to anchor pullout ranged between 156 and 269 N. The load to suture slippage ranged between 66 and 109 N. All sutures were better held between the metal rods (mean, 21; 95% confidence interval [CI], 19.2 to 23.3) than with polyetheretherketone rods (mean, 17; 95% CI, 15.7 to 18.1) or poly-L-lactide acid rods (mean, 18; 95% CI, 17.6 to 18.4). In the case of suture anchors that hold the sutures by clamping, the hold of the suture in the anchor may be far lower than the pullout strength of the anchor from bone, because the sutures just slip out from the anchor through the clamping mechanism. This is well explained by the low static friction achieved between the tested sutures and the test rods made of anchor materials. The use of knotless suture anchors appears quick and easy to perform; however, most of the anchor systems could not even reach half of the anchor pullout strength from bone before suture slippage occurred. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Recycling Suture Limbs from Knotless Suture Anchors for Arthroscopic Shoulder Stabilization

    OpenAIRE

    Johnson, Timothy S.; DiPompeo, Christine M.; Ismaeli, Zahra C.; Porter, Polly A.; Nicholson, Shannon L.; Johnson, David C.

    2014-01-01

    Recurrent shoulder instability often leads to labral abnormality that requires surgical intervention that may require fixation with suture anchors. The proposed surgical technique allows the surgeon to achieve 2 points of fixation around the labrum and/or capsule with a single suture secured to the glenoid with a knotless anchor. Instead of cutting and discarding the residual suture limbs after anchor insertion, this technique uses the residual suture limbs of the knotless anchor for a second...

  3. Suture complications in a teaching institution among patients undergoing uterosacral ligament suspension with permanent braided suture

    OpenAIRE

    Yazdany, Tajnoos; Yip, Sallis; Bhatia, Narender N.; Nguyen, John N.

    2010-01-01

    Introduction and hypothesis Our study aimed to identify the rate of suture complications over a 5-year period using braided permanent suture for uterosacral ligament suspension (USLS) surgery. Methods We reviewed the medical records of patients who underwent vaginal uterosacral ligament suspensions using braided polyester suture. Outcome measures included rate and timing of suture complications, patient symptoms post-operatively, efficacy of treatment modalities and surgical success. Results ...

  4. Should nylon corneal sutures be routinely removed?

    Science.gov (United States)

    Jackson, H.; Bosanquet, R.

    1991-01-01

    Three groups of patients who had undergone cataract extraction through a corneal incision closed with 10/0 nylon sutures one, two, and three years previously were recalled to determine the incidence of suture related complications. Broken corneal sutures were found in 87.5% of patients after two years and 90% after three years and were causing symptoms in over half the patients. It is recommended that 10/0 nylon corneal sutures be routinely removed no later than one year after surgery. Images PMID:1751460

  5. Comparison between suture anchor and transosseous suture for the modified-Broström procedure.

    Science.gov (United States)

    Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin

    2012-06-01

    This prospective, randomized study was conducted to compare clinical outcomes of the modified Broström procedure using suture anchor or transosseous suture technique for chronic ankle instability. Forty patients were followed for more than 2 years after modified Broström procedure. Twenty procedures using a suture anchor and 20 procedures using a transosseous suture were performed by one surgeon. The clinical evaluation consisted of the Karlsson scale and the Sefton grading system. Talar tilt and anterior talar translation were measured on anterior and varus stress radiographs. The Karlsson scale had improved significantly to 90.8 points in the suture anchor group, and to 89.2 points in the transosseous suture group. According to Sefton grading system, 18 patients (90%) in suture anchor group and 17 patients (85%) in transosseous suture group achieved satisfactory results. The talar tilt angle and anterior talar translation improved significantly to 5.9 degrees and 4.2 mm in suture anchor group, and to 5.4 degrees and 4.1 mm in transosseous suture group, respectively. No significant differences existed in clinical and functional outcomes between the two techniques for ligament reattachment. Both modified Broström procedures using the suture anchor and transosseous suture seem to be effective treatment methods for chronic lateral ankle instability.

  6. Suture strength and angle of load application in a suture anchor eyelet.

    Science.gov (United States)

    Deakin, Mark; Stubbs, David; Bruce, Warwick; Goldberg, Jerome; Gillies, Ronald M; Walsh, William R

    2005-12-01

    To assess the effect of suture material, anchor orientation, and anchor eyelet design on the static loading properties of suture anchors. Biomechanical bench study. Two metallic suture anchors, Mitek GII (Mitek, Westwood, MA) and Corkscrew (Arthrex, Naples, FL) and a bioabsorbable anchor (Biocorkscrew; Arthrex) were tested with single strand of No. 2 Ethibond (Ethicon, Norderstedt, Germany) or No. 2 FiberWire (Arthrex) suture. Suture pull angle was varied through 0 degrees, 45 degrees, and 90 degrees with the anchor rotation angle in either a sagittal or coronal plane. Constructs were tested to failure using an MTS 858 Bionix testing machine (Material Testing Systems, Eden Prairie, MN). Peak loads, stiffness, energy to peak load, and failure modes were determined for all samples. FiberWire showed superior static mechanical properties when compared with single-strand Ethibond over all testing conditions (P Suture pull angle had a significant effect on load to failure with both metallic anchors but not on the bioabsorbable anchor (P Suture pull angle and anchor rotation angle play an important role in the failure load of suture when placed in an eyelet. The polyaxial nature of the Biocorkscrew eyelet allows for increased degrees of freedom but introduces failure of the suture eyelet as a new failure mode. The loading direction and placement of the suture anchor plays a role in the performance of the suture anchor-suture complex.

  7. Buried absorbable polyglactin 910 sutures do not result in stronger wounds in porcine full thickness skin incisions.

    Science.gov (United States)

    Townsend, Katy L; Lear, William; Robertson, Bria L; Kruzic, Jamie J

    2016-10-01

    To test the hypothesis that the mechanical strength of wounds closed with a combination of buried dermal absorbable sutures and superficial nonabsorbable nylon sutures will be higher than wounds closed with only superficial nonabsorbable nylon sutures. Four Yucatan pigs were anesthetized and each received four 4.5cm full thickness incisions on their dorsal surfaces, placed 8cm apart. Half of all incisions were randomly allocated and repaired with 3-0 polyglactin 910 (Vicryl(™)) buried dermal absorbable sutures and superficial 3-0 nylon sutures, using a simple interrupted pattern. The other half received only 3-0 nylon sutures. Two pigs were humanely euthanized at day 10, with specimen harvest for mechanical testing; the other two pigs had superficial nylon sutures removed at day 10, as per current clinical practice, and were humanely euthanized at day 42, with specimen harvest for mechanical testing. Tensile loads were applied perpendicularly to the wounds with a displacement rate of 40mm per minute. Wounds at day 42 were >9 times stronger than wounds at day 10 (p<0.0001). There was no difference in average wound strength at either day 10 or day 42 between wounds with and without buried dermal absorbable sutures. Buried dermal absorbable sutures failed to provide additional wound support at either 10 or 42 days. This result may have immediate implications for clinicians who perform cutaneous surgery and keep superficial sutures in for at least 10 days. Future research will be directed to shorter time studies, other buried dermal absorbable suture materials, and alternatives to buried dermal absorbable sutures. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Transoral Mucosal Excision Sutured Gastroplasty

    Science.gov (United States)

    Legner, Andras; Altorjay, Aron; Juhasz, Arpad; Stadlhuber, Rudolph; Reich, Viktor; Hunt, Brandon; Rothstein, Richard

    2014-01-01

    Introduction. An outpatient transoral endoscopic procedure for gastroesophageal reflux disease (GERD) and obesity would be appealing if safe, effective, and durable. We present the first in human experience with a new system. Methods. Eight patients with GERD (3) and obesity (5) were selected according to a preapproved study protocol. All GERD patients had preprocedure manometry and pH monitoring to document GERD as well as quality of life and symptom questionnaires. Obese patients (body mass index >35) underwent a psychological evaluation and tests for comorbidities. Under general anesthesia, a procedure was performed at the gastroesophageal junction including mucosal excision, suturing of the excision beds for apposition, and suture knotting. Results. One patient with micrognathia could not undergo the required preprocedural passage of a 60 F dilator and was excluded. The first 2 GERD patients had incomplete procedures due to instrument malfunction. The subsequent 5 subjects had a successfully completed procedure. Four patients were treated for obesity and had an average excess weight loss of 30.3% at 2-year follow-up. Of these patients, one had an 8-mm outlet at the end of the procedure recognized on video review—a correctable error—and another vomited multiple times postoperatively and loosened the gastroplasty sutures. The treated GERD patient had resolution of reflux-related symptoms and is off all antisecretory medications at 2-year follow-up. Her DeMeester score was 8.9 at 24 months. Conclusion. The initial human clinical experience showed promising results for effective and safe GERD and obesity therapy. PMID:24623807

  9. Comparison of V-Loc™ 180 wound closure device and Quill™ PDO knotless tissue-closure device for intradermal closure in a porcine in vivo model: evaluation of biomechanical wound strength.

    Science.gov (United States)

    Gingras, Kristen; Zaruby, Jeffrey; Maul, Don

    2012-05-01

    The objective of this study was to compare the biomechanical strength of two barbed suture devices: V-Loc™ 180 Wound Closure Device and Quill™ PDO Knotless Tissue-Closure Device following primary cosmetic skin closures in a porcine dermal model. This prospective randomized, controlled in vivo trial compared size 3/0 V-Loc™ 180 device to size 2/0 Quill™ PDO device. Both products were tested for dermal closure in adult porcine models and evaluated at five timepoints. At postoperative days 0, 3, 7, 14, and 28 sutured tissue regions were excised post mortem and tested for intradermal wound holding strength. Wounds closed with V-Loc™ 180 device were stronger than Quill™ PDO device at days 0, 3, 7, and 14 with these differences being significant (p PDO was 10.38 kgf (p = 0.002). At day 7, the average maximum load of V-Loc™ 180 was 10.4 kgf and Quill™ PDO was 7.56 kgf (p = 0.001). Throughout the duration of the study, there was no suture extrusion or tissue distortion and all wounds healed with no major complications. In this study, V-Loc™ 180 device was significantly stronger than Quill™ PDO device during the critical phases of wound healing in skin. Copyright © 2012 Wiley Periodicals, Inc.

  10. Evaluation of cosmetic appearance of herniotomy wound scars in African children: Comparison of tissue glue and subcuticular suturing

    Directory of Open Access Journals (Sweden)

    Ademuyiwa A

    2009-01-01

    Full Text Available Aim: To evaluate the cosmetic appearance of herniotomy wound scars closed using either the tissue glue or subcuticular suturing technique. Materials and Methods: Prospective randomised control study; randomisation into tissue glue and suturing groups. Ethical clearance obtained. Cosmetic outcome were based on visual analogue scale by parents and Hollander wound evaluation scale by a Plastic Surgeon blinded to the wound closure method. Results: Fifty one wounds were evaluated, 26 in the tissue glue group and 25 in the suturing group. Parents′ evaluation using Visual Analogue scale (VAS showed that in the suturing group, 17 parents (68% gave a VAS of 8cm while six parents (24% gave a score of 7cm. Two parents (8% gave a score of 9cm. In the tissue glue group, 22 parents (84.6% scored the scar of their children as 8 or 9cm on the VAS while four parents (15.4% gave a score of 7cm. The median VAS was 8cm for both groups with a range of 7 to 9cm. The Chi- square test showed that the parents preferred tissue glue compared with subcuticular suturing (X2 = 7.90, P < 0.05. The Hollander Wound Evaluation Scale (HWES used by Plastic Surgeon showed 21 herniotomy wounds (84% had a score of 6 in the suturing group while four wounds (16% had a score of 5. In the tissue glue group, 19 wounds (73% had a score of 6, six wounds (23.1% had a score of 5 and a patient (3.8% had a score of 4. The median score is 6 for both groups. There was no statistically significant difference between both groups (X 2 = 1.481, P = 0.393. Conclusion: This study has shown that the cosmetic outcome of wound closure using the tissue glue technique and subcuticular suturing technique are similar.

  11. Closure technique for leaking wound resulting from thermal injury during phacoemulsification.

    Science.gov (United States)

    Haldar, Keshab; Saraff, Rashmi

    2014-09-01

    We describe a method of wound closure with a conjunctival flap in cases of wound burn. A fornix-based conjunctival flap is raised to adequately cover the wound. Then, a single horizontal mattress suture with 10-0 monofilament nylon is passed to appose the wound. The conjunctival flap is hinged to the corneal end of the loop so the conjunctival flap covers the wound when the suture is tied. The wound is thus sealed by conjunctiva with optimum suture tension. This suture was applied in 5 patients with clear corneal incisions who developed wound burn during phacoemulsification. All had an uneventful recovery with a sealed wound from the first postoperative day and satisfactory visual outcomes with low residual astigmatism at the final refraction. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Something of the nature of gross sutural growth.

    Science.gov (United States)

    Sarnat, B G

    1986-10-01

    A series of experiments was performed on monkeys, rabbits, and turtles to study gross sutural growth of bones. Radiopaque implants in conjunction with serial gross and radiographic measurements were employed. Differences in growth were observed between 5 facial sutures and also the same suture at different times. Growth was greatest at the zygomaticotemporal suture and least at the premaxillomaxillary suture. The nasal bone side of the frontonasal suture grew about twice as fact as the frontal bone side. In the turtle shell the midsagittal suture grew faster than a transverse suture. In all of the animals the rate of sutural growth decreased with increase in age. No gross regional growth disturbance was noted after resection of the frontonasal, midpalatine, or transpalatine sutures. After extirpation of the median palatine suture, it re-formed, in an eccentric position, in a number of instances. We concluded that bone growth that occurred at sutures was secondary or compensatory to some other factor.

  13. Comparison of pharyngocutaneous fistula closure with and without bacterial cellulose in a rat model.

    Science.gov (United States)

    Demir, Berat; Sarı, Murat; Binnetoglu, Adem; Yumusakhuylu, Ali Cemal; Filinte, Deniz; Tekin, İshak Özel; Bağlam, Tekin; Batman, Abdullah Çağlar

    2018-04-01

    The present study aimed to compare the effects of bacterial cellulose used for closure of pharyngocutaneous fistulae, a complication of total laryngectomy, with those of primary sutures in a rat model. Thirty female Sprague-Dawley underwent experimental pharyngoesophagotomy and were grouped depending on the material used for pharyngocutaneous fistula closure: group I, which received primary sutures alone, group II, which received bacterial cellulose alone; and group III, which received both. After 7 days, the rats were sacrificed. Pharyngocutaneous fistula development was assessed, the gross wound was inspected, and histological examination was conducted. Pharyngocutaneous fistulae developed in 12 rats (41%) in all: 6 from group I (21%), 4 from group II (14%) and 2 from group III (7%). Fibroblast density and inflammatory cell infiltration were significantly greater in group III than group I. We concluded that bacterial cellulose may be useful for pharyngocutaneous fistula closure. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Does hyaluronic acid-carboxymethylcellulose (HA-CMC) membrane interfere with the healing of intestinal suture lines and abdominal incisions?

    Science.gov (United States)

    Yamaner, Sümer; Kalayci, Murat; Barbaros, Umut; Balik, Emre; Bulut, Türker

    2005-03-01

    Although hyaluronic acid-carboxymethylcellulose (HA-CMC) membrane has the advantage of preventing intraabdominal adhesions, it has theoretical risk of negative effects on the healing of intestinal suture lines by forming a barrier between the suture lines and neighboring serosal surfaces. This study evaluated the effect of HA-CMC on bowel anastomoses, scar healing, and intraabdominal adhesion formation. Two groups of 10 male Sprague-Dawley rats were examined. In the first group, laparotomy was performed with a median incision. Colotomy on the cecum and a single-layer repair of the bowel wall was performed. HA-CMC membrane was placed on the cecal suture line and under the laparotomy incision before abdominal closure. The second group had the same procedure but no HA-CMC membrane was placed. The animals were killed on postoperative day 14. Intraabdominal adhesions, laparotomy suture line endurance, bursting pressure of the repaired cecal wall, and tissue hydroxyproline levels were determined. The repaired cecal wall was also examined histopathologically. The statistical analyses revealed that HA-CMC prevented intraabdominal adhesions significantly. No negative effects of this material on the healing of the bowel and laparotomy suture lines were observed. HA-CMC appears to be a safe material to prevent intraabdominal adhesions, without negative effects on the healing of abdominal incisions and bowel suture lines.

  15. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  16. Metopic suture of Taung (Australopithecus africanus) and its implications for hominin brain evolution.

    Science.gov (United States)

    Falk, Dean; Zollikofer, Christoph P E; Morimoto, Naoki; Ponce de León, Marcia S

    2012-05-29

    The type specimen for Australopithecus africanus (Taung) includes a natural endocast that reproduces most of the external morphology of the right cerebral hemisphere and a fragment of fossilized face that articulates with the endocast. Despite the fact that Taung died between 3 and 4 y of age, the endocast reproduces a small triangular-shaped remnant of the anterior fontanelle, from which a clear metopic suture (MS) courses rostrally along the midline [Hrdlička A (1925) Am J Phys Anthropol 8:379-392]. Here we describe and interpret this feature of Taung in light of comparative fossil and actualistic data on the timing of MS closure. In great apes, the MS normally fuses shortly after birth, such that unfused MS similar to Taung's are rare. In humans, however, MS fuses well after birth, and partially or unfused MS are frequent. In gracile fossil adult hominins that lived between ∼3.0 and 1.5 million y ago, MS are also relatively frequent, indicating that the modern human-like pattern of late MS fusion may have become adaptive during early hominin evolution. Selective pressures favoring delayed fusion might have resulted from three aspects of perinatal ontogeny: (i) the difficulty of giving birth to large-headed neonates through birth canals that were reconfigured for bipedalism (the "obstetric dilemma"), (ii) high early postnatal brain growth rates, and (iii) reorganization and expansion of the frontal neocortex. Overall, our data indicate that hominin brain evolution occurred within a complex network of fetopelvic constraints, which required modification of frontal neurocranial ossification patterns.

  17. Biomechanical comparison of screw-in suture anchor-suture combinations used for Bankart repair.

    Science.gov (United States)

    Sparks, Brad S; Nyland, John; Nawab, Akbar; Blackburn, Ethan; Krupp, Ryan; Caborn, David N M

    2010-03-01

    Bankart repair laxity may contribute to pathologic joint instability. This biomechanical study compared two screw-in suture anchor-suture combinations under tensile loads. Twelve pairs of scapulae were implanted with either a 3 mm diameter, 14 mm long poly-L/D-lactide suture anchor with a suture eyelet (Group 1) or a 3.1 mm diameter, 11 mm long polylactide suture anchor with a molded eyelet (Group 2). Constructs were cyclically loaded between 25 and 50 N with a 25 N load increase every 25 cycles. Group 2 displayed greater displacement at failure, had more specimens with > or =2 mm displacement by the 50 N interval (P = 0.014), and had displaced more by 100 N (P suture anchor-suture loops, the rehabilitation timetable, and the timing of return to unrestricted activities.

  18. Self-directed practice schedule enhances learning of suturing skills

    National Research Council Canada - National Science Library

    Safir, Oleg; Williams, Camille K; Dubrowski, Adam; Backstein, David; Carnahan, Heather

    2013-01-01

    ...) on learning suturing skills. Participants watched an instructional video for simple interrupted, vertical mattress and horizontal mattress suturing then completed a pretest to assess baseline skills...

  19. [Suture of lingual nerve: Technical note].

    Science.gov (United States)

    Garconnet, J; Foletti, J-M; Guyot, L; Chossegros, C

    2015-06-01

    Because of its anatomical position, the lingual nerve may be severed during oral surgical procedures, such as third molar removal. Early suturing of the nerve promotes better recovery. We describe the end-to-end suture of this nerve. The suture is carried-out under general anesthesia. The approach is made in the mouth floor, in the same way as for submandibular gland lithiasis transoral removal. This approach allows good exposure and some laxity to displace the nerve stumps. The latter can then be sutured under microscope assistance before closing the mucosa. Lingual nerve suture is a simple, quick and inexpensive procedure. Unlike other procedures, it cannot be used in case of large loss of substance because of the small amount of laxity of the nerve. Nerve function recovery is better if performed before the 6th post-traumatic month, and in young patients. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Flexor tendons repair: effect of core sutures caliber with increased number of suture strands and peripheral sutures. A sheep model.

    Science.gov (United States)

    Uslu, M; Isik, C; Ozsahin, M; Ozkan, A; Yasar, M; Orhan, Z; Erkan Inanmaz, M; Sarman, H

    2014-10-01

    Surgeons have aimed to achieve strong repair so as to begin early active rehabilitation programs for flexor tendon injury. Multi-strand suture techniques were developed to gain improved gap resistance and ultimate force compared with the respective two-strand techniques. In vivo studies indicate that multiple strands may cause ischemia during the intrinsic healing process by decreasing the total cross-sectional area of the injured site, unless the total cross-sectional area of the sutures is not decreased. The hypothesis was to design an in vitro study to understand the biomechanical relationship between suture calibers of core sutures with increased number of suture strands and peripheral suture on final repair strength. Sixty fresh sheep forelimb flexor digitorum profundus tendons were randomly placed into three groups (A, B, and C), each containing 20 specimens, for tendon repair. Two-, four-, and eight-strand suture techniques were respectively used in Groups A, B, and C. A simple running peripheral suture technique was used in Subgroups A2, B2, and C2. For each repaired tendon, the 2-mm gap-formation force, 2-mm gap-formation strength, maximum breaking force and maximum breaking strength were determined. Differences in 2-mm gap-formation force and 2-mm gap-formation strength were found between Subgroups A1 and A2, B1 and B2, and C1 and C2. Between Groups A and B, A and C, and B and C, there was no difference as well. Both the number of strands and the ratio between the total suture volume and tendon volume at the repair site are important for ideal repair. If the total cross-sectional area of the sutures is equal in 2-strand, 4-strand, and 8-strand procedure, there is no difference in the strength of the repair. A decrease in caliber size suture requires more passes to achieve the same strength. Instead, it is much better to use peripheral suture techniques to improve the strength of the repair with larger diameter 2-strand core sutures. Copyright © 2014

  1. Partial nephrectomy: Is there an advantage of the self-retaining barbed suture in the perioperative period? A matched case-control comparison

    NARCIS (Netherlands)

    Zondervan, Patricia J.; Gozen, Ali S.; Opondo, Dedan; Rassweiler, Jens J.; de la Rosette, Jean J.; Laguna, M. Pilar

    2012-01-01

    Objective To evaluate the efficacy of the self-retaining barbed suture (SRBS) in renal defect repair during partial nephrectomy (PN), by assessing perioperative outcomes. Methods From June 2010 on we have been using the SRBS for superficial layer closure during open and laparoscopic PN in two

  2. New adjustable suture technique for trabeculectomy

    Directory of Open Access Journals (Sweden)

    Vespasiano Rebouças-Santos

    2013-06-01

    Full Text Available PURPOSE: To describe an adjustable suture (AS experimental model that allows for tightening, loosening and retightening of the suture tension in trabeculectomy. METHODS: Standard trabeculectomy was performed in fifteen pig eyeballs. All pig eyes were tested twice: one test with conventional suture in both flap's corners (conventional suture group and another test with a conventional suture at one corner and an adjustable suture in the other corner (AS group. The order in which each test was performed was defined by randomization. Intraocular pressure was measured at three time points: T1 when the knots were tightened; T2 when the AS was loosened or the conventional knot was removed; and T3 when the AS was retightened in the AS group or five minutes after the knot removal in the conventional suture group. RESULTS: The mean Intraocular pressure was similar between the two groups at time point 1 (p=0.97. However, significant Intraocular pressure differences were found between eyes in the conventional and adjustable suture groups at time points 2 (12.6 ± 4.2 vs 16.3 ± 2.3 cmH2O, respectively, p=0.006 and 3 (12.2 ± 4.0 vs 26.4 ± 1.7cmH2O, respectively; p=0.001. While the conventional technique allowed only Intraocular pressure reduction (following the knot removal; T2 and T3, the AS technique allowed both Intraocular pressure reduction (T2 and elevation (T3 through the management (loosening and retightening of the suture. CONCLUSION: This experimental model provides an effective noninvasive postoperative mechanism of suture tension adjustment.

  3. Disturbed spontaneous brain activity pattern in patients with primary angle-closure glaucoma using amplitude of low-frequency fluctuation: a fMRI study

    Directory of Open Access Journals (Sweden)

    Huang X

    2015-07-01

    Full Text Available Xin Huang,1,* Yu-Lin Zhong,1,* Xian-Jun Zeng,2 Fuqing Zhou,2 Xin-Hua Liu,1 Pei-Hong Hu,1 Chong-Gang Pei,1 Yi Shao,1 Xi-Jian Dai21Department of Ophthalmology, 2Department of Radiology, The First Affiliated Hospital of Nanchang University, Nangchang, Jiangxi, People’s Republic of China*These authors contributed equally to this workObjective: The aim of this study is to use amplitude of low-frequency fluctuation (ALFF as a method to explore the local features of spontaneous brain activity in patients with primary angle -closure glaucoma (PACG and ALFFs relationship with the behavioral performances.Methods: A total of twenty one patients with PACG (eight males and 13 females, and twenty one healthy subjects (nine males and twelve females closely matched in age, sex, and education, each underwent a resting-state functional magnetic resonance imaging scan. The ALFF method was used to assess the local features of spontaneous brain activity. The correlation analysis was used to explore the relationships between the observed mean ALFF signal values of the different areas in PACG patients and the thickness of the retinal nerve fiber layer (RNFL. Results: Compared with the healthy subjects, patients with PACG had significant lower ALFF areas in the left precentral gyrus, bilateral middle frontal gyrus, bilateral superior frontal gyrus, right precuneus, and right angular gyrus, and higher areas in the right precentral gyrus. In the PACG group, there were significant negative correlations between the mean ALFF signal value of the right middle frontal gyrus and the left mean RNFL thickness (r=-0.487, P=0.033, and between the mean ALFF signal value of the left middle frontal gyrus and the right mean RNFL thickness (r=-0.504, P=0.020. Conclusion: PACG mainly involved in the dysfunction in the frontal lobe, which may reflect the underlying pathologic mechanism of PACG.Keywords: angle-closure glaucoma, amplitude of low-frequency fluctuation, functional

  4. The reading man flap for closure of large meningomyelocele defects.

    Science.gov (United States)

    Mutaf, Mehmet; Temel, Metin; Günal, Ertan

    2012-05-01

    Closure of the skin defect in myelomeningocele repair is an essential step that determines the quality of the surgical result. In large myelomeningoceles, however, adequate skin coverage may not be accomplished by direct closure or skin undermining. In such cases, the skin defect is best repaired using flaps. The aim of this study is to evaluate the reading man procedure for closure of large meningomyelocele defect. In this procedure, after neurosurgical repair and closure of the placode, the defect surgically becomes a circle in shape. Then, the circular defect is closed by transposition of two skin flaps designed in an unequal Z-plasty manner. Over 5 years, the reading man procedure was used for closure of large meningomyelocele defects in seven patients (four females and three males), aged between 1.5 and 6 months. The defect size was 10.5×7.25 cm (8.5×5.3 and 12.6×9.5 cm) on average. The localisation of the lesions was thoracolumbar in two patients and lumbosacral in five patients. In all patients, a successful tension-free one-stage closure was obtained without dog-ear formation. Except for one patient with minimal tip necrosis, healing was uneventful without any complications. There was no patient with late breakdown of the wound during 1.5 years (8 months-4 years) of mean follow-up. The reading man procedure enables the surgeon to achieve a tension-free defect closure of considerably large meningomyeleocele defects. Using two well-vascularised fasciocutaneous flaps, it provides a durable coverage and soft tissue padding over the neural tissues with no suture seam at midline. With these advantages, the Reading Man Procedure seems to be a useful and safe alternative for closure of large meningomyelocele defects. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Barbed suture vs traditional suture in single-port total laparoscopic hysterectomy.

    Science.gov (United States)

    Song, Taejong; Lee, San-Hui

    2014-01-01

    To compare surgical outcomes between barbed suture and traditional suture used in repair of the vaginal vault during single-port total laparoscopic hysterectomy (TLH). Case-control study (Canadian Task Force classification II-2). Two institutions. One hundred two patients with benign uterine disease. Single-port TLH using barbed suture (n = 43) or traditional suture (n = 59). Patient characteristics (age, body mass index, demographic data), procedures performed, uterine weight, and uterine disease were similar between the 2 study groups. There were also no differences in operative complications, conversion to other surgical approaches, operative blood loss, postoperative pain, and duration of hospital stay between the 2 groups. Use of barbed suture significantly reduced the time required for vaginal cuff suturing (11.4 vs 22.5 minutes; p suture is less technically demanding than traditional suture (p suture in single-port TLH may aid surgeons by reducing operative time, suturing time, and surgical difficulty. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  6. Triclosan-coated sutures do not reduce leg wound infections after coronary artery bypass grafting.

    Science.gov (United States)

    Seim, Bjørn Edvard; Tønnessen, Theis; Woldbaek, Per Reidar

    2012-09-01

    Leg wound infection is a common complication after coronary artery bypass grafting (CABG). Suture contamination has been suggested as a mechanism of surgical site infections. Vicryl Plus(®) is a polyglacitin suture coated with the antiseptic chemical substance Triclosan, which has been shown to inhibit the growth of Staphylococcus aureus in vitro. The first aim of the present study was to compare Vicryl Plus with conventional Vicryl(®) sutures with regard to leg wound infections following CABG. The second aim was to examine patient- and operative characteristics, which are assumed to predict leg wound infections. After statistical calculations a priori, 328 CABG patients were prospectively randomized to leg wound closure with Vicryl Plus (164 patients) or conventional Vicryl sutures (164 patients). Incidences of leg wound infection and predictors of infection related to patient- and operative characteristics were examined. The incidence of leg wound infections was 10.4% (17/163) in the Vicryl group, and 10.0% (16/160) in the Vicryl Plus group (P = 1.00). Patients with leg wound infections had increased body mass index and prolonged extracorporeal circulation and aortic clamping time compared with patients without infections. In the present study, we report for the first time that Vicryl Plus did not reduce the incidence of leg wound infections in patients undergoing CABG. Obesity and prolonged time of extracorporeal circulation were both associated with the increased risk of infections. Currently, the clinical role and indication for the use of Vicryl Plus have yet to be defined.

  7. Eyelid closure at death

    Directory of Open Access Journals (Sweden)

    A D Macleod

    2009-01-01

    Full Text Available Aim: To observe the incidence of full or partial eyelid closure at death. Materials and Methods: The presence of ptosis was recorded in 100 consecutive hospice patient deaths. Results: Majority (63% of the patients died with their eyes fully closed, however, 37% had bilateral ptosis at death, with incomplete eye closure. In this study, central nervous system tumor involvement and/or acute hepatic encephalopathy appeared to be pre-mortem risk factors of bilateral ptosis at death. Conclusion: Organicity and not psychogenicity is, therefore, the likely etiology of failure of full eyelid closure at death.

  8. Influence of different length of core suture purchase among suture row on the strength of 6-strand tendon repairs.

    Science.gov (United States)

    Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori

    2015-01-01

    In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.

  9. Sternal exploration or closure

    Science.gov (United States)

    You may have already been receiving wound care or treatment and antibiotics. There are two main reasons for doing exploration and closure procedures for the chest wound after heart surgery: Get rid ...

  10. Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

    Science.gov (United States)

    Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y

    2016-05-01

    Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.

  11. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable surgical gut suture. 878.4830 Section... surgical gut suture. (a) Identification. An absorbable surgical gut suture, both plain and chromic, is an... “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878...

  12. 21 CFR 878.4840 - Absorbable polydioxanone surgical suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable polydioxanone surgical suture. 878.4840... polydioxanone surgical suture. (a) Identification. An absorbable polydioxanone surgical suture is an absorbable... for the device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for...

  13. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polyamide surgical suture. 878.5020... polyamide surgical suture. (a) Identification. Nonabsorbable polyamide surgical suture is a nonabsorbable... indicated for use in soft tissue approximation. The polyamide surgical suture meets United States...

  14. 21 CFR 882.4650 - Neurosurgical suture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical suture needle. 882.4650 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle. (a) Identification. A neurosurgical suture needle is a needle used in suturing during neurosurgical...

  15. 21 CFR 878.4495 - Stainless steel suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of 316L...

  16. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polypropylene surgical suture. 878... Nonabsorbable polypropylene surgical suture. (a) Identification. Nonabsorbable polypropylene surgical suture is... suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. Monograph for...

  17. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Natural nonabsorbable silk surgical suture. 878... Natural nonabsorbable silk surgical suture. (a) Identification. Natural nonabsorbable silk surgical suture... Bombycidae. Natural nonabsorbable silk surgical suture is indicated for use in soft tissue approximation...

  18. COMPARISON OF ABSORBABLE EXTRA LONG TERM POLY HYDROXY BUTYRATE SUTURE VS NON ABSORBABLE (POLYPROPYLENE) SUTURE FOR ABDOMINAL WALL CLOSURE

    National Research Council Canada - National Science Library

    Mallikarjun; Vinay Sagar; Kiran

    2015-01-01

    ... . patients are divided into group I includes 102 patients with continuous technique using non absorbable polypropylene, group II includes 91 patients with interrupted technique using non absorbable...

  19. Suture anchor repair yields better biomechanical properties than transosseous sutures in ruptured quadriceps tendons.

    Science.gov (United States)

    Petri, M; Dratzidis, A; Brand, S; Calliess, T; Hurschler, C; Krettek, C; Jagodzinski, M; Ettinger, M

    2015-04-01

    This human cadaveric study compares the biomechanical properties of quadriceps tendon repair with suture anchors and the commonly applied transosseous sutures. The hypothesis was that suture anchors provide at least equal results concerning gap formation and ultimate failure load compared with transosseous suture repair. Thirty human cadaveric knees underwent tenotomy followed by repair with either 5.5-mm-double-loaded suture anchors [titanium (TA) vs. resorbable hydroxyapatite (HA)] or transpatellar suture tunnels using No. 2 Ultrabraid™ and the Krackow whipstitch. Biomechanical analysis included pretensioning the constructs with 20 N for 30 s and then cyclic loading of 250 cycles between 20 and 100 N at 1 Hz in a servohydraulic testing machine with measurement of elongation. Ultimate failure load analysis and failure mode analysis were performed subsequently. Tendon repairs with suture anchors yielded significantly less gap formation during cyclic loading (20th-250th cycle: TA 1.9 ± 0.1, HA 1.5 ± 0.5, TS 33.3 ± 1.9 mm, p sutures. Common failure mode was pull-out of the eyelet within the suture anchor in the HA group and rupture of the suture in the TA and TS group. Quadriceps tendon repair with suture anchors yields significantly better biomechanical results than the commonly applied transosseous sutures in this human cadaveric study. These biomechanical findings may change the future clinical treatment for quadriceps tendon ruptures. Randomised controlled clinical trials are desirable for the future. Not applicable, controlled laboratory human cadaveric study.

  20. Closure of the Paleotethys in the External Hellenides : Constraints from U-Pb ages of magmatic and detrital zircons (Crete)

    NARCIS (Netherlands)

    Zulauf, G.; Dörr, W.; Fisher-Spurlock, S. C.; Gerdes, A.; Chatzaras, V.|info:eu-repo/dai/nl/374329249; Xypolias, P.

    2015-01-01

    Paleotethys was a highly mobile oceanic realm pinching into the supercontinent Pangea between Gondwana and Eurasia in the late Paleozoic/early Mesozoic. Published Paleotethyan reconstructions reveal that the time of Paleotethys closure and the position of its suture are highly debated. We present

  1. Evaluation of absorbable and nonabsorbable sutures for repair of achilles tendon rupture with a suture-guiding device.

    Science.gov (United States)

    Kocaoglu, Baris; Ulku, Tekin Kerem; Gereli, Arel; Karahan, Mustafa; Turkmen, Metin

    2015-06-01

    The purpose of this study was to compare the functional and clinical results of Achilles tendon repairs with an Achilles tendon suture-guiding device using nonabsorbable versus absorbable sutures. We hypothesized that the absorbable suture would have clinical results comparable to those of the nonabsorbable suture for Achilles tendon repair with an Achilles tendon suture-guiding system. From January 2010 to September 2013, 48 consecutive patients who had sustained a spontaneous rupture of the Achilles tendon underwent operative repair with an Achilles tendon suture-guiding device using 2 different suture types. All ruptures were acute. The patients were divided equally into 2 groups according to suture type. In the nonabsorbable suture group, No. 2 braided nonabsorbable polyethylene terephthalate sutures were used, and in the absorbable suture group, braided absorbable polyglactin sutures were used. The average age of the patients was 38 years (range, 28-50 years). Functional outcome scores and complications were evaluated. All patients had an intact Achilles repair after surgery. The American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot clinical outcome scores were 98 (range, 90-100) in the nonabsorbable suture group and 96.8 (range, 87-100) in the absorbable suture group. All patients returned to their previous work. The absorbable suture group had fewer postoperative complications (0%) than the nonabsorbable suture group (12.5%) (P suture in the treatment of Achilles tendon repair by an Achilles tendon suture-guiding system was associated with a lower incidence of suture reaction; however, functionally the results were not notably different from those using a traditional nonabsorbable suture. We conclude that repair with absorbable sutures is appropriate for Achilles tendon ruptures. Level II, prospective comparative study. © The Author(s) 2015.

  2. Facial thread lifting with suture suspension

    National Research Council Canada - National Science Library

    Joana de Pinho Tavares; Carlos Augusto Costa Pires Oliveira; Rodolfo Prado Torres; Fayez Bahmad Jr

    ...: To analyze data published in the literature on the durability of results, their effectiveness, safety, and risk of serious adverse events associated with procedures using several types of threading sutures. Methods...

  3. Paper tape in the closure of abdominal wounds.

    Science.gov (United States)

    Chao, T C; Tsaez, F Y

    1990-07-01

    Wounds closed by adhesive tapes have less inflammatory reaction, a lower rate of wound infection, greater tensile strength and better cosmetic results than sutured or stapled wounds. Special backing tapes, such as Steri-Strip, have been reported to have satisfactory results in closing laparotomy wounds. However, they are more expensive than paper tape. Sterile paper tape had adequate adhesive and supporting strength in the closure of abdominal wounds. The wounds closed with paper tape healed well and had satisfactory cosmetic results. Paper tape is a nonexpensive and convenient alternative to close abdominal wounds.

  4. Biomechanical properties of suture anchor repair compared with transosseous sutures in patellar tendon ruptures: a cadaveric study.

    Science.gov (United States)

    Ettinger, Max; Dratzidis, Antonios; Hurschler, Christof; Brand, Stephan; Calliess, Tilman; Krettek, Christian; Jagodzinski, Michael; Petri, Maximilian

    2013-11-01

    Ruptures of the patellar tendon are debilitating injuries requiring surgical repair. Reliable data about the most appropriate suture technique and suture material are missing. The standard procedure consists of refixing the tendon with sutures in transpatellar tunnels, sometimes combined with augmentation. Suture anchors provide at least equal results concerning gap formation during cyclic loading and ultimate failure load compared with transosseous suture repair. Controlled laboratory study. A total of 30 human cadaveric patellar tendons underwent tenotomy followed by repair with 5.5-mm titanium suture anchors, 5.5-mm resorbable hydroxyapatite suture anchors, or transpatellar suture tunnels with No. 2 Ultrabraid and the Krackow whipstitch technique. Biomechanical analysis included pretensioning the constructs at 20 N for 30 seconds and then cyclic loading of 250 cycles between 20 and 100 N at 1 Hz in a servohydraulic testing machine with measurement of elongation. After this, ultimate failure load and failure mode analysis was performed. Compared with transosseous sutures, tendon repairs with suture anchors yielded significantly less gap formation during cyclic loading (P suture anchor in the hydroxyapatite anchor group and rupture of the suture in the titanium anchor group and-at lower load to failure-in the transosseous group. Patellar tendon repair with suture anchors yields significantly better biomechanical results than repair with the commonly applied transosseous sutures. These findings may be of relevance for future clinical treatment of patellar tendon ruptures. Randomized controlled clinical trials comparing suture anchors to transosseous suture repair are desirable.

  5. Comparison of All-Inside Suture Technique with Traditional Pull-out Suture and Suture Anchor Repair Techniques for Flexor Digitorum Profundus Attachment to Bone

    Science.gov (United States)

    Chu, Jennifer Y; Chen, Tony; Awad, Hani A.; Elfar, John; Hammert, Warren C.

    2015-01-01

    Purpose One goal in repairing Zone 1 flexor digitorum profundus (FDP) injuries is to create a tendon-bone construct strong enough to allow early rehabilitation while minimizing morbidity. This study introduces an alternative all-inside suture repair technique and compares it biomechanically with pull-out suture and double suture anchor repairs. Methods Repairs were performed on thirty cadaver fingers. In all-inside suture repairs (n=8), the FDP tendon was attached to bone with two 3-0 Ethibond sutures and tied over the dorsal aspect of distal phalanx. Pull-out suture repairs (n=8) were performed with 2-0 Prolene suture and tied over a dorsal button. There were two suture anchor repair groups: Arthrex Micro Corkscrew anchors preloaded with 2-0 FiberWire suture (n=7) and Depuy Micro Mitek anchors preloaded with 3-0 Orthocord suture (n=7). Repair constructs were tested using a servohydraulic materials testing system and loaded until the repair lost 75% of its strength. Results There were no statistically significant differences in tensile stiffness, ultimate load, or work to failure between the repairs. Failure mode was suture stretch and gap formation >2mm at the repair site for all pull-out suture repairs and 7 of 8 all-inside suture repairs. Two of the Arthrex Micro Corkscrew repairs and five of the Depuy Micro Mitek repairs failed by anchor pull out. Conclusions This cadaveric biomechanical study showed no difference in tensile stiffness, ultimate load, and work to failures between an all-inside suture repair technique for zone 1 FDP repairs and previously described pull-out suture and suture anchor repair techniques. The all-inside suture technique also has the advantages of avoiding an external button and the cost of anchors. Therefore, it should be considered as an alternative to other techniques. Clinical Relevance This study introduces a new FDP reattachment technique that avoids some of the complications of current techniques. PMID:23578439

  6. A Systematic Review of Systematic Reviews and Panoramic Meta-Analysis: Staples versus Sutures for Surgical Procedures

    Science.gov (United States)

    Hemming, Karla; Pinkney, Thomas; Futaba, Kay; Pennant, Mary; Morton, Dion G.; Lilford, Richard J.

    2013-01-01

    Objective To systematically evaluate the evidence across surgical specialties as to whether staples or sutures better improve patient and provider level outcomes. Design A systematic review of systematic reviews and panoramic meta-analysis of pooled estimates. Results Eleven systematic reviews, including 13,661 observations, met the inclusion criteria. In orthopaedic surgery sutures were found to be preferable, and for appendicial stump sutures were protective against both surgical site infection and post surgical complications. However, staples were protective against leak in ilecolic anastomosis. For all other surgery types the evidence was inconclusive with wider confidence intervals including the possibly of preferential outcomes for surgical site infection or post surgical complication for either staples or sutures. Whilst reviews showed substantial variation in mean differences in operating time (I2 94%) there was clear evidence of a reduction in average operating time across all surgery types. Few reviews reported on length of stay, but the three reviews that did (I2 0%, including 950 observations) showed a non significant reduction in length of stay, but showed evidence of publication bias (P-value for Egger test 0.05). Conclusions Evidence across surgical specialties indicates that wound closure with staples reduces the mean operating time. Despite including several thousand observations, no clear evidence of superiority emerged for either staples or sutures with respect to surgical site infection, post surgical complications, or length of stay. PMID:24116028

  7. Pullout strength of suture anchors in comparison with transosseous sutures for rotator cuff repair.

    Science.gov (United States)

    Pietschmann, Matthias F; Fröhlich, Valerie; Ficklscherer, Andreas; Hausdorf, Jörg; Utzschneider, Sandra; Jansson, Volkmar; Müller, Peter E

    2008-05-01

    Suture anchors are increasingly gaining importance in rotator cuff surgery. This means they will be gradually replacing transosseous sutures. The purpose of this study was to compare the stability of transosseous sutures with different suture anchors with regard to their pullout strength depending on bone density. By means of bone densitometry (CT scans), two groups of human humeral head specimens were determined: a healthy and a osteopenic bone group. Following anchor systems were being tested: SPIRALOK 5.0 mm (resorbable, DePuy Mitek), Super Revo 5 mm (titanium, Linvatec), UltraSorb (resorbable, Linvatec) and the double U-sutures with Orthocord USP 2 (partly resorbable, DePuy Mitek) and Ethibond Excel 2 (non-resorbable, Ethicon). The suture anchors/double U-sutures were inserted in the greater tuberosity 12 times. An electromechanical testing machine was used for cyclic loading with power increasing in stages. We recorded the ultimate failure loads, the system displacements and the modes of failure. The suture anchors tended to bring about higher ultimate failure loads than the transosseous double U-sutures. This difference was significant in the comparison of the Ethibond suture and the SPIRALOK 5.0 mm-both in healthy and osteopenic bone. Both the suture materials and the SPIRALOK 5.0 mm showed a significant difference in pullout strength on either healthy or osteopenic bone; the titanium anchor SuperRevo 5 mm and the tilting anchor UltraSorb did not show any significant difference in healthy or osteopenic bone. There was no significant difference concerning system displacement (healthy and osteopenic bone) between the five anchor systems tested. The pullout strength of transosseous sutures is neither on healthy nor on osteopenic bone higher than that of suture anchors. Therefore, even osteopenic bone does not constitute a valid reason for the surgeon to perform open surgery by means of transosseous sutures. The choice of sutures in osteopenic bone is of little

  8. Shear lag sutures: Improved suture repair through the use of adhesives.

    Science.gov (United States)

    Linderman, Stephen W; Kormpakis, Ioannis; Gelberman, Richard H; Birman, Victor; Wegst, Ulrike G K; Genin, Guy M; Thomopoulos, Stavros

    2015-09-01

    Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. Copyright © 2015 Acta Materialia Inc. Published by Elsevier

  9. Quilting suture in the donor site of the transverse rectus abdominis musculocutaneous flap in breast reconstruction.

    Science.gov (United States)

    Rossetto, Luís A; Garcia, Elvio B; Abla, Luis F; Neto, Miguel S; Ferreira, Lydia M

    2009-03-01

    The purpose of this study was to evaluate the effects of quilting suture (placement of stitches between the superficial fascia in the supraumbilical remaining flap and the musculoaponeurotic layer of the anterior abdominal wall) at the donor site of the transverse rectus abdominis musculocutaneous flap in breast reconstruction. There is a theory that the use of quilting suture, during the closure of the donor site with the abdominal flap, causes collapse of the dead space and enables the flap to rest, thus diminishing factors that may interfere in its adherence and help to reduce complications. Between January 2004 and March 2005, we performed 30 breast reconstructions using a unipedicled transverse rectus abdominis musculocutaneous flap. The sample was randomly distributed in 2 groups: 15 patients with quilting suture (group A) and 15 patients without quilting suture (group B). The study focused on daily drain output (mL), time to drain removal (days), and possible donor site complications (%). Group A presented an average of 4.2 days for removal of the drain and group B, 6.93 days, with a statistically significant difference (P < 0.001). Concerning the total volume upon removal of the drain, group A presented an average of 434.7 mL and group B, 620.7 mL, with a statistically significant difference (P = 0.002). Group A presented 13.3% complications at the donor site and group B, 53.3%, with a statistically significant difference (P = 0.05). The quilting suture in this study reduces the permanence of drains, total volume of tissue fluids upon drain removal, and complication rates.

  10. Modified method for bronchial suture by Ramirez Gama compared to separate stitches suture: experimental study

    Directory of Open Access Journals (Sweden)

    Vitor Mayer de Moura

    Full Text Available OBJECTIVE: To experimentally compare two classic techniques described for manual suture of the bronchial stump. METHODS: We used organs of pigs, with isolated trachea and lungs, preserved by refrigeration. We dissected 30 bronchi, which were divided into three groups of ten bronchi each, of 3mm, 5mm, and 7mm, respectively. In each, we performed the suture with simple, separated, extramucosal stitches in five other bronchi, and the technique proposed by Ramirez and modified by Santos et al in the other five. Once the sutures were finished, the anastomoses were tested using compressed air ventilation, applying an endotracheal pressure of 20mmHg. RESULTS: the Ramirez Gama suture was more effective in the bronchi of 3, 5 and 7 mm, and there was no air leak even after subjecting them to a tracheal pressure of 20mmHg. The simple interrupted sutures were less effective, with extravasation in six of the 15 tested bronchi, especially in the angles of the sutures. These figures were not significant (p = 0.08. CONCLUSION: manual sutures of the bronchial stumps were more effective when the modified Ramirez Gama suture was used in the caliber bronchi arms when tested with increased endotracheal pressure.

  11. Tank closure reducing grout

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, T.B.

    1997-04-18

    A reducing grout has been developed for closing high level waste tanks at the Savannah River Site in Aiken, South Carolina. The grout has a low redox potential, which minimizes the mobility of Sr{sup 90}, the radionuclide with the highest dose potential after closure. The grout also has a high pH which reduces the solubility of the plutonium isotopes. The grout has a high compressive strength and low permeability, which enhances its ability to limit the migration of contaminants after closure. The grout was designed and tested by Construction Technology Laboratories, Inc. Placement methods were developed by the Savannah River Site personnel.

  12. Vacuum-assisted closure for skin necrosis after revision total knee arthroplasty.

    Science.gov (United States)

    Sarman, Hakan; Muezzinoglu, Umit S; Memisoglu, Kaya; Baran, Tuncay

    2016-10-01

    Although skin necrosis following total knee arthroplasty or revision total knee arthroplasty is rare, it may cause severe complications. Skin changes begin with superficial infections and may result in removal of the prosthesis. Treatment of skin necrosis is an important factor, which determines the prognosis of the prosthesis. Several techniques have been defined for sufficient closure. In this article, we present the case of a patient who was treated for skin necrosis that developed after knee revision arthroplasty, using serial debridement, convergence sutures and an intermittent vacuum-assisted closure device (KCI Inc., San Antonio, TX). © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  13. Arthroscopic Fixation of Tibial Eminence Fractures: A Biomechanical Comparative Study of Screw, Suture, and Suture Anchor.

    Science.gov (United States)

    Li, Ji; Yu, Yang; Liu, Chunhui; Su, Xiangzheng; Liao, Weixiong; Li, Zhongli

    2018-01-31

    To compare biomechanical outcomes of 4 different arthroscopic techniques for fixation of tibial eminence fractures. Twenty-four skeletally mature, fresh-frozen cadaveric knees were divided into 4 comparison groups based on the fixation method: screw fixation (group A), traditional sutures fixation with 2 FiberWire sutures (group B), a modified suture technique with 2 FiberWire sutures that created neckwear knots to firmly trap the fracture fragment (group C), or suture anchors which was based on the suture bridge technique primarily used in the shoulder for repair of rotator cuff tears and greater tuberosity fractures (group D). A tibial eminence fracture was created in each knee for subsequent fixation. After fixation, each knee underwent cyclic loading of 100 N to assess the displacement change after 500 cycles of the fixation construct. Afterward, a single tensile failure test load was performed to assess the ultimate failure load, stiffness, and failure mode for each specimen. All specimens survived cyclic testing and were subsequently loaded to failure. Group C had the highest ultimate failure load (P Suture fixation using the neckwear knots technique provides superior fixation with regard to higher ultimate failure load, and absorbable suture anchor fixation with the suture bridge technique provides less displacement under cyclic loading conditions. Both techniques exhibited superior biomechanical properties compared with traditional screw and suture fixation. The new techniques showed satisfactory biomechanical properties and provided more choice for surgeons in the treatment of tibial eminence fractures. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Suture-related complications after congenital cataract surgery: Vicryl versus Mersilene sutures.

    Science.gov (United States)

    Bar-Sela, Shai M; Spierer, Oriel; Spierer, Abraham

    2007-02-01

    To evaluate 10-0 polyester sutures (Mersilene) and 10-0 absorbable polyglactin sutures (Vicryl) for small-incision congenital cataract surgery. Goldschleger Eye Institute, Sheba Medical Center, Tel-Aviv University, Tel-Aviv, Israel. A retrospective review comprised 51 patients (70 eyes) who had small-incision congenital cataract extraction and intraocular lens implantation between 1999 and 2005. Surgery was done using Mersilene sutures or Vicryl sutures. Retinoscopy and a careful examination for suture-related complications were done 1 week after surgery and then every month for 6 months. The sutures were removed in cases of local tissue reaction but not for high postoperative astigmatism. The t test was used to evaluate postoperative astigmatism and the Fisher exact test, to evaluate the difference in the incidence of suture-related complications. The patients' age ranged from 2 months to 15 years. Ten cases (18%) of corneal vascularization occurred in the Mersilene group during the 6-month follow-up period. This necessitated suture removal, after which 1 incident of endophthalmitis occurred. In contrast, no suture-related complications were noted in the Vicryl group during that time. The difference in the incidence of complications between the 2 groups approached statistical significance (P = .07). Mean astigmatism 1 week postoperatively was 2.3 diopters (D) +/- 2.1 (SD) in the Mersilene group, which was significantly higher than in the Vicryl group (mean 1.4 +/- 1.1 D) (P = .038). However, the mean astigmatism decreased to less than 1.0 D in both groups during the 6-month follow-up period. Vicryl sutures are recommended for small-incision congenital cataract surgery.

  15. 40 CFR 264.113 - Closure; time allowed for closure.

    Science.gov (United States)

    2010-07-01

    ... corrective action program, compile all ground-water monitoring data, and evaluate the effect of the continued... assurance for closure and post-closure care as necessary and appropriate, to reflect any changes due to the presence of hazardous constituents in the non-hazardous wastes, and changes in closure activities...

  16. Facial thread lifting with suture suspension

    Directory of Open Access Journals (Sweden)

    Joana de Pinho Tavares

    Full Text Available Abstract Introduction: The increased interest in minimally-invasive treatments, such as the thread lifting, with lower risk of complications, minimum length of time away from work and effectiveness in correcting ptosis and aging characteristics has led many specialists to adopt this technique, but many doubts about its safety and effectiveness still limit its overall use. Objective: To analyze data published in the literature on the durability of results, their effectiveness, safety, and risk of serious adverse events associated with procedures using several types of threading sutures. Methods: Literature review using the key words "thread lift", "barbed suture", "suture suspension" and "APTOS". Due to the scarcity of literature, recent reports of facial lifting using threads were also selected, complemented with bibliographical references. Result: The first outcomes of facial lifting with barbed sutures remain inconclusive. Adverse events may occur, although they are mostly minor, self-limiting, and short-lived. The data on the maximum effect of the correction, the durability of results, and the consequences of the long-term suture stay are yet to be clarified. Conclusion: Interest in thread lifting is currently high, but this review suggests that it should not yet be adopted as an alternative to rhytidectomy.

  17. Facial thread lifting with suture suspension.

    Science.gov (United States)

    Tavares, Joana de Pinho; Oliveira, Carlos Augusto Costa Pires; Torres, Rodolfo Prado; Bahmad, Fayez

    2017-05-09

    The increased interest in minimally-invasive treatments, such as the thread lifting, with lower risk of complications, minimum length of time away from work and effectiveness in correcting ptosis and aging characteristics has led many specialists to adopt this technique, but many doubts about its safety and effectiveness still limit its overall use. To analyze data published in the literature on the durability of results, their effectiveness, safety, and risk of serious adverse events associated with procedures using several types of threading sutures. Literature review using the key words "thread lift", "barbed suture", "suture suspension" and "APTOS". Due to the scarcity of literature, recent reports of facial lifting using threads were also selected, complemented with bibliographical references. The first outcomes of facial lifting with barbed sutures remain inconclusive. Adverse events may occur, although they are mostly minor, self-limiting, and short-lived. The data on the maximum effect of the correction, the durability of results, and the consequences of the long-term suture stay are yet to be clarified. Interest in thread lifting is currently high, but this review suggests that it should not yet be adopted as an alternative to rhytidectomy. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  18. The evaluation of fibrin tissue adhesive for skin closure following eyelid surgery

    OpenAIRE

    De Silva, Julian

    2011-01-01

    The use of fibrin tissue adhesives in clinical practice has grown over the past 10 years, and there has been increased use of adhesives in different surgical subspecialties. Conventional suture closure of periorbital tissues is effective however may result in complications, which has led to the search for other techniques and innovations. Although tissue adhesives have been used in clinical practice there is a paucity of randomized controlled studies that have evaluated their adva...

  19. Internal inguinal ring closure by laparoscopy using homologous pericardium grafts in horses

    OpenAIRE

    Spagnolo, Julio David; Sinhorini, Idercio Luis; Baccarin, Raquel Yvonne Arantes; Ambrosio, Aline Magalhães; Souto, Maria Teresa de Mello; Ida, Keila Kazue; Silva, Luis Claudio Lopes Correia da

    2016-01-01

    ABSTRACT: The occlusion of inguinal ring is the treatment to avoid the inguinal hernia in horses. The aim of this study is evaluate the efficacy of homologous pericardium grafts for internal inguinal ring closure in horses, comparing mechanical or manual laparoscopic suture. Cross over study, using six healthy intact male Mangalarga breed horses aged between 3 and 12 years. Horses were operated under general anesthesia in 25º Trendelenburg position. Five laparoscopic portals were employed. Pe...

  20. ROCKET PORT CLOSURE

    Science.gov (United States)

    Mattingly, J.T.

    1963-02-12

    This invention provides a simple pressure-actuated closure whereby windowless observation ports are opened to the atmosphere at preselected altitudes. The closure comprises a disk which seals a windowless observation port in rocket hull. An evacuated instrument compartment is affixed to the rocket hull adjacent the inner surface of the disk, while the outer disk surface is exposed to the atmosphere through which the rocket is traveling. The pressure differential between the evacuated instrument compartment and the relatively high pressure external atmosphere forces the disk against the edge of the observation port, thereby effecting a tight seai. The instrument compartment is evacuated to a pressure equal to the atmospheric pressure existing at the altitude at which it is desiretl that the closure should open. When the rocket reaches this preselected altitude, the inwardly directed atmospheric force on the disk is just equaled by the residual air pressure force within the instrument compartment. Consequently, the closure disk falls away and uncovers the open observation port. The separation of the disk from the rocket hull actuates a switch which energizes the mechanism of a detecting instrument disposed within the instrument compartment. (AE C)

  1. Mail Office annual closure

    CERN Multimedia

    2013-01-01

    On the occasion of the annual closure of CERN, there will be no mail distributed on Friday 20 December 2013 but mail will be collected in the morning. Nevertheless, you will still be able to bring your outgoing mail to Building 555-R-002 until 12 noon.  

  2. Ring closure in actin polymers

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Supurna, E-mail: supurna@rri.res.in [Raman Research Institute, Bangalore 560080 (India); Chattopadhyay, Sebanti [Doon University, Dehradun 248001 (India)

    2017-03-18

    We present an analysis for the ring closure probability of semiflexible polymers within the pure bend Worm Like Chain (WLC) model. The ring closure probability predicted from our analysis can be tested against fluorescent actin cyclization experiments. We also discuss the effect of ring closure on bend angle fluctuations in actin polymers. - Highlights: • Ring closure of biopolymers. • Worm like chain model. • Predictions for experiments.

  3. Ring closure in actin polymers

    OpenAIRE

    Sinha, Supurna; Chattopadhyay, Sebanti

    2017-01-01

    We present an analysis for the ring closure probability of semiflexible polymers within the pure bend Worm Like Chain (WLC) model. The ring closure probability predicted from our analysis can be tested against fluorescent actin cyclization experiments.We also discuss the effect of ring closure on bend angle fluctuations in actin polymers.

  4. Suture With Resorbable Cones: Histology and Physico-Mechanical Features

    Science.gov (United States)

    Consiglio, Fabio; Pizzamiglio, Roberto; Parodi, Pier Camillo; De Biasio, Fabrizio; Machin, Pier Nicola; Di Loreto, Carla; Gamboa, Mabel

    2016-01-01

    Background Silhouette Sutures (Kolster Methods, Inc., Corona, CA) exhibit different biological characteristics at various time points after their placement. Objectives The goals of this study were to understand the biological reactions of Silhouette Sutures in human tissues at different time intervals and to determine the index of resistance of the sutures in subcutaneous tissue. Methods Histologic examination was performed on section soft tissue containing the sutures at 1 month, 3 months, 6 months, and 1 year after suture placement. The study comprised 8 patients, each of whom received 4 sutures in the lower abdomen under local anesthesia. The sutures were placed exactly 1 month, 3 months, 6 months, and 1 year before planned post-bariatric abdominal surgery. Dynamometric evaluation was performed on a never-used suture and on sutures removed from 1 year after placement. The scar process around the threads was also examined. Results A progressive increase in scar tissue around the sutures was observed. One year after placement, there was a reduction of 16.7% in yield and tensile strength and a reduction of 14.29% in elongation at break, relative to the never-used suture. By 1 year, the cones in polylactic and glycolic acids had been replaced by scar tissue. Conclusions Fibrous tissue around the sutures increased progressively over time, and was most prominent at the level of the nodes. Cones were completely resorbed within 6 months. A reduction in the index of resistance of the suspension sutures occurred over 1 year. PMID:26879301

  5. [Predictable tip suture techniques in rhinoplasty].

    Science.gov (United States)

    Papel, I D

    2010-09-01

    Recontouring the nasal tip in rhinoplastic procedures has generated a wide range of surgical techniques. These range from aggressive cartilage resection, division, grafting, or suture methods. Each of these categories contains many variations described in hundreds of publications. The goal of this communication is to describe a predictable, reproducible technique that can be used in a wide variety of rhinoplasty operations. Based on pre-existing anatomy variations of this technique can be adopted. The author described the basic technique in 2004 [1].The cornerstone of the technique is a predictable method of narrowing the interdomal space utilizing a suture technique. This procedure employs a pair of permanent sutures designed to minimize distortion, valve impingement and overcorrection. It can be performed through intranasal or external approaches. This paper will define the wide interdomal space, describe the technique, and demonstrate the efficacy of the technique in 250 rhinoplasty procedures. In addition, variations of the technique for specific goals will be shown.

  6. Cold Plasma Welding System for Surgical Skin Closure: In Vivo Porcine Feasibility Assessment.

    Science.gov (United States)

    Harats, Moti; Lam, Amnon; Maller, Michael; Kornhaber, Rachel; Haik, Josef

    2016-09-29

    Cold plasma skin welding is a novel technology that bonds skin edges through soldering without the use of synthetic materials or conventional wound approximation methods such as sutures, staples, or skin adhesives. The cold plasma welding system uses a biological solder applied to the edges of a skin incision, followed by the application of cold plasma energy. The objectives of this study were to assess the feasibility of a cold plasma welding system in approximating and fixating skin incisions compared with conventional methods and to evaluate and define optimal plasma welding parameters and histopathological tissue response in a porcine model. The cold plasma welding system (BioWeld1 System, IonMed Ltd, Yokneam, Israel) was used on porcine skin incisions using variable energy parameters. Wound healing was compared macroscopically and histologically to incisions approximated with sutures. When compared to sutured skin closure, cold plasma welding in specific system parameters demonstrated comparable and favorable wound healing results histopathologically as well as macroscopically. No evidence of epidermal damage, thermal or otherwise, was encountered in the specified parameters. Notably, bleeding, infection, and wound dehiscence were not detected at incision sites. Skin incisions welded at extreme energy parameters presented second-degree burns. Implementation of cold plasma welding has been shown to be feasible for skin closure. Initial in vivo results suggest cold plasma welding might provide equal, if not better, healing results than traditional methods of closure.

  7. Effect of Suturation Plus Surgicel Application on Post-Tonsillectomy Bleeding and Pain.

    Science.gov (United States)

    Cetiner, Hasan; Cavusoglu, Ilker; Duzer, Sertac; Sakallioglu, Oner; Susaman, Nihat; Yildirim, Yavuz Sultan Selim

    2017-10-01

    The aim of this study was to evaluate the effect of suturation (tonsillary fossa closure) plus Surgicel application on postoperative bleeding and pain after tonsillectomies performed using a classical dissection method. A prospective, randomized, double-blind, clinical trial was performed on 760 patients undergoing tonsillectomy or adenotonsillectomy during a 5-year period. After excluding patients with hemorrhagic disorder, chronic disease, and peritonsillar abscess, both tonsils were removed via classic dissection technique (cold knife or blunt dissection) and then electrocauterized for hemostasis. The tonsillar fossa randomly assigned to the treatment protocol (Group 1) was closed by sutures, following Surgicel application. The other side was unaltered and acted as the control (Group 2). Pain was evaluated every day for 10 days postoperatively, and bleeding was reported at any time. A total of 760 patients (393 males, 367 females) between the ages of 4 and 35 years (mean age 13.46 ± 7.98) were included in the study. Bleeding was observed in 31 patients: 8 from Group 1; and 23 from Group 2 (95% confidence interval [CI], P < 0.05). The average pain score was greater in Group 1 than in Group 2 on each postoperative day (95% CI, P < 0.05). Suturation plus Surgicel application increased pain levels while decreasing bleeding incidence during the postoperative period.

  8. Midline abdominal wall closure: a new prophylactic mesh concept.

    Science.gov (United States)

    Bellón, Juan M; López-Hervás, Pedro; Rodríguez, Marta; García-Honduvilla, Natalio; Pascual, Gemma; Buján, Julia

    2006-10-01

    Despite intense research efforts, incisional hernias continue to be a problem in patients who undergo laparotomy. This study was designed to reinforce the midline laparotomy closure by including a new prosthetic design between the edges of the surgical wound. A midline incision was made in New Zealand white rabbits and closed by inserting a polypropylene strip, T-shaped in cross-section, between the incisional borders. The T was placed upside down such that the horizontal arm of the T, whose surface is coated with extra-low pore size expanded polytetrafluoroethylene, made contact with the visceral peritoneum. The mesh was secured by a mass polypropylene 3/0 running suture. Surgery outcomes in these animals were compared with those in which the surgical wound was closed by simple suture and with control, nonoperated animals. The T-mesh induced an increased amount of scar tissue at the midline, where neoformed recipient tissue appeared around the polypropylene mesh filaments. The expanded polytetrafluoroethylene lamina became appropriately mesothelialized. Compared with the simple suture, the T-mesh provided a significant gain in biomechanical strength at postoperative week 6 (43.99+/-4.17 Newtons and 56.96+/-10.94 Newtons, respectively, p abdominal wall (82.25+/-7.60 Newtons versus 79.55+/-11.46 Newtons). Data were expressed as mean +/- standard deviation. The use of a nonabsorbable biomaterial for midline laparotomy closure significantly improves its biomechanical resistance. Used in high-risk patients or even prophylactically, this technique could reduce the incidence of incisional hernia.

  9. [Suture techniques and material in surgery of flexor tendons].

    Science.gov (United States)

    Pillukat, T; Fuhrmann, R; Windolf, J; van Schoonhoven, J

    2017-03-01

    Adhesions and scar formation between flexor tendons and the surrounding tissue are only contemporarily avoidable by movement of flexor tendons. Concepts with active follow-up protocols are more favorable than passive mobilization. The main risks of flexor tendon repair are rupture of the tendon suture, insidious gap formation and resistance to tendon gliding within the tendon sheath. Currently, there is no consensus with respect to the optimal suture technique or suture material. Nevertheless, there are some principles worth paying attention to, such as using stronger suture material, blocking stitches, suture techniques with four or more strands as well as circular running sutures. A technically acceptable compromise, even for the less experienced, is currently the four-strand suture combined with a circular running suture. It maintains sufficient stability for active motion follow-up protocols without resistance.

  10. Clinical and histological comparison of polyglycolic acid suture with black silk suture after minor oral surgical procedure.

    Science.gov (United States)

    Balamurugan, R; Mohamed, Masroor; Pandey, Vijayendra; Katikaneni, Hari Krishna Rao; Kumar, K R Ashok

    2012-07-01

    Any suture material, absorbable or nonabsorbable, elicits a kind of inflammatory reaction within the tissue. Nonabsorbable black silk suture and absorbable polyglycolic acid suture were compared clinically and histologically on various parameters. This study consisted of 50 patients requiring minor surgical procedure, who were referred to the Department of Oral and Maxillofacial Surgery. Patients were selected randomly and sutures were placed in the oral cavity 7 days preoperatively. Polyglycolic acid was placed on one side and black silk suture material on the other. Seven days later, prior to surgical procedure the sutures will be assessed. After the surgical procedure the sutures will be placed postoperatively in the same way for 7 days, after which the sutures will be assessed clinically and histologically. The results of this study showed that all the sutures were retained in case of polyglycolic acid suture whereas four cases were not retained in case of black silk suture. As far as polyglycolic acid suture is concerned 25 cases were mild, 18 cases moderate and seven cases were severe. Black silk showed 20 mild cases, 21 moderate cases and six severe cases. The histological results showed that 33 cases showed mild, 14 cases moderate and three cases severe in case of polyglycolic acid suture. Whereas in case of black silk suture 41 cases were mild. Seven cases were moderate and two cases were severe. Black silk showed milder response than polyglycolic acid suture histologically. The polyglycolic acid suture was more superior because in all 50 patients the suture was retained. It had less tissue reaction, better handling characteristics and knotting capacity.

  11. Estudo comparativo da cicatrização de enterorrafias em planos aposicional e invaginante no cólon descendente de eqüinos Comparative study between appositional and inverting pattern for closure of descending colon enterotomies in equines

    Directory of Open Access Journals (Sweden)

    F.A. Lucas

    2001-10-01

    Full Text Available O estudo foi conduzido com o objetivo de comparar o processo cicatricial do cólon descendente de eqüinos, quando submetido a duas técnicas de sutura, uma em plano aposicional e outra em dois planos com invaginação. Foram utilizados 15 eqüinos sadios e a intervenção cirúrgica foi realizada com os animais em decúbito lateral direito, sob anestesia geral inalatória. O acesso à cavidade abdominal foi feito pelo flanco esquerdo, e após exteriorização do cólon descendente, realizaram-se duas enterotomias de 5cm de extensão cada, distanciadas 20cm uma da outra. Os animais foram aleatoriamente distribuídos em cinco grupos de três animais cada e sacrificados aos 3, 7, 14, 21 e 35 dias pós-operatório. O exame necroscópico revelou presença de aderências nos dois padrões de sutura. Em nove eqüinos foram observadas aderências no padrão de sutura aposicional (60,0% ± 12,6 e em quatro no padrão com invaginação (26,6 % ± 11,4. Não foi verificada interferência com o trânsito intestinal em nenhum paciente. O exame histopatológico revelou regeneração da camada mucosa a partir do sétimo dia de pós-operatório em ambos os tipos de sutura. O fio de poliglactina 910 empregado nas enterorrafias do cólon descendente se mostrou resistente, de fácil manuseio e com boa capacidade para manter os nós aplicados, causando moderada reação inflamatória do tipo granulomatosa.This trial was carried out in order to compare the healing process of the descending colon in horses, submitted to two distinctive suture techniques - appositional pattern and inverting pattern. Fifteen healthy horses were used and the surgical intervention was accomplished with the animals in right lateral recumbency, under inhalatory anesthesia. The abdominal cavity approach was done by the left flank, and after exteriorization of the descending colon, two enterotomies, 5cm long, and 20cm apart one from each other were done. The horses were randomly distributed

  12. A Biomechanical Analysis of the Interlock Suture and a Modified Kessler-Loop Lock Flexor Tendon Suture

    Directory of Open Access Journals (Sweden)

    Wenfeng Yang

    Full Text Available OBJECTIVE: In this work, we attempted to develop a modified single-knot Kessler-loop lock suture technique and compare the biomechanical properties associated with this single-knot suture technique with those associated with the conventional modified Kessler and interlock suture techniques. METHODS: In this experiment, a total of 18 porcine flexor digitorum profundus tendons were harvested and randomly divided into three groups. The tendons were transected and then repaired using three different techniques, including modified Kessler suture with peritendinous suture, interlock suture with peritendinous suture, and modified Kessler-loop lock suture with peritendinous suture. Times required for suturing were recorded and compared among groups. The groups were also compared with respect to 2-mm gap load, ultimate failure load, and gap at failure. RESULTS: For tendon repair, compared with the conventional modified Kessler suture technique, the interlock and modified Kessler-loop lock suture techniques resulted in significantly improved biomechanical properties. However, there were no significant differences between the interlock and modified Kessler-loop lock techniques with respect to biomechanical properties, gap at failure, and time required. CONCLUSIONS: The interlock and modified Kessler-loop lock techniques for flexor tendon sutures produce similar mechanical characteristics in vitro.

  13. Serum cortisol of Sahel goats following rumenotomy with assorted anaesthetics and sutures

    Directory of Open Access Journals (Sweden)

    Abubakar Mshelia Saidu

    2016-06-01

    Full Text Available The utmost need for pragmatic combination of surgical sutures and local anaesthetic that would evoke minimal post-surgical stress response and allow uncomplicated healing is essential for successful surgeries. Fifteen Sahel goats were randomly allocated into three groups A, B and C to quantitatively assay (ELISA serum cortisol profiles following rumenotomy, as markers of surgical stress. Diazepam at 0.2 mg/kg was administered intravenously to groups A and B with subsequent lidocaine HCl and bupivacaine inverted-L block respectively. Group C did not receive any treatment. Chromic catgut (CCG and polyglycolic acid (PGA sutures were used for rumen and abdominal muscles closure for groups A and B respectively and nylon for skin closure. Blood samples were taken at post anaesthetic induction (PAI and post-surgery at 0, 5, 8, 24, 48 and 72 h. The Group A goats expressed serum cortisol that was significantly high 52.76 ± 6.12 ng/mL at 5 h post-surgery. At 8 h post-surgery serum cortisol for both groups A (72.53 ± 3.79 ng/mL and B (61.59 ± 3.90 ng/mL were at their peak. Serum cortisol levels compared to the baseline data were significantly different (P  0.05. Cortisol responses unambiguously indicate that diazepam-bupivacaine induce less stress than Diazepam-lidocaine, hence a preferred anesthesia. Moreover, polyglycolic acid sutures are associated with less inflammatory reaction than chromic catgut.

  14. Ossification degrees of cranial sutures determined with flat-panel computed tomography: narrowing the age estimate with extrema.

    Science.gov (United States)

    Harth, Sebastian; Obert, Martin; Ramsthaler, Frank; Reuss, Christina; Traupe, Horst; Verhoff, Marcel A

    2010-05-01

    Since Broca's time (1824-1880), ossification of the neurocranial sutures has been used as a characteristic of age. Current approaches include the visual macroscopic examination of ecto and endocranial sutures. The evaluation of the cross-section of sutures usually necessitates the destruction of the neurocranium. In a nondestructive alternative approach that was tested within the context of the "Digital Forensic Osteology" project that ran in cooperation with the Virtopsy-Project, it emerged that the resolution of conventional multi-slice computed tomography data sets was not high enough to image sutures. Thus for the experiments presented here, the eXplore Locus Ultra flat-panel computed tomography scanner from GE Healthcare was used. Calottes were scanned during autopsy and then immediately returned to the corpse. So far, the skullcaps of 221 individuals have been scanned. The cross-sections of 14 suture segments could be assessed for seven previously defined stages of ossification. In a converse step, the 14 highest and lowest age estimate values corresponding to the individual stages of suture closure found were estimated for each calotte. The obtained ranges narrowing down the age estimate were evaluated with statistics. A mean value of 43.31 years for the range of narrowed age estimates shows that this method can be a useful aid in estimating age. The results of intra- and inter-observer tests showed good overall agreement between the findings of three observers. This method is suitable for a nondestructive age estimation and can be used for the entire calotte.

  15. 21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.

    Science.gov (United States)

    2010-04-01

    ... surgical suture. 878.5035 Section 878.5035 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 878.5035 Nonabsorbable expanded polytetrafluoroethylene surgical suture. (a) Identification. Nonabsorbable expanded polytetrafluoroethylene (ePTFE) surgical suture is a monofilament, nonabsorbable, sterile...

  16. 21 CFR 878.4930 - Suture retention device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device. (a) Identification. A suture retention device is a device, such as a retention bridge, a surgical...

  17. Polyethylene glycol hydrogel spinal sealant (DuraSeal Spinal Sealant) as an adjunct to sutured dural repair in the spine: results of a prospective, multicenter, randomized controlled study.

    Science.gov (United States)

    Kim, Kee D; Wright, Neill M

    2011-11-01

    A prospective, multicenter, randomized, two-arm, single-blind, investigational device exemption pivotal study. To assess the efficacy and the safety of a polyethylene glycol (PEG) hydrogel spinal sealant (DuraSeal Spinal Sealant) as an adjunct to sutured dural repair compared with standard of care methods (control) to obtain a watertight dural closure in patients undergoing an intentional durotomy during spinal surgery. If a watertight dural closure is not achieved, cerebrospinal fluid leak with associated complications may occur. The PEG hydrogel spinal sealant is an Food and Drug Administration (FDA)-approved adjunct to sutured dural repair in spine surgery. This synthetic, absorbable hydrogel sealant works in the presence of fluid, conforms to irregular surfaces, and demonstrates strong adherence and compliance to tissue, without interfering with underlying tissue visibility. A total of 158 patients were treated at 24 centers after they were randomized on the basis of an approximately 2:1 ratio (sealant:control); 102 received the PEG hydrogel spinal sealant and 56 received standard care. The primary end point was intraoperative watertight closure. Secondary end points included evaluations of postoperative cerebrospinal fluid leak, infection, and wound healing. Patients treated with the PEG hydrogel spinal sealant had a significantly higher rate of watertight closure than the control (100% vs. 64.3%, P hydrogel spinal sealant evaluated in this study is safe and effective for providing watertight closure when used as an adjunct to sutured dural repair during spinal surgery. This readily available tool is superior to other standard of care technologies commonly used to achieve intraoperative watertight dural closure.

  18. Summer season | Cafeteria closures

    CERN Multimedia

    2013-01-01

    Please note the following cafeteria closures over the summer season: Bldg. 54 closed from 29/07/2013 to 06/09/2013. Bldg. 13: closed from 13/07/2013 to 06/09/2013. Restaurant No. 2, table service (brasserie and restaurant): closed from 01/08/2013 to 06/09/2013. Bldg. 864: closed from 29/07/2013 to 06/09/2013. Bldg. 865: closed from 29/07/2013 to 06/09/2013.

  19. Simple suture and anchor in rabbit hips

    Science.gov (United States)

    Garcia Filho, Fernando Cal; Guarniero, Roberto; de Godoy Júnior, Rui Maciel; Pereira, César Augusto Martins; Matos, Marcos Almeida; Garcia, Lucas Cortizo

    2012-01-01

    Objective Using biomechanical studies, this research aims to compare hip capsulorrhaphy in rabbits, carried out with two different techniques: capsulorrhaphy with simple sutures and with anchors. Method Thirteen New Zealand Albino (Oryctolaguscuniculus) male rabbits, twenty-six hip joints, were used. First, a pilot project was performed with three rabbits (six hip joints). This experiment consisted of ten rabbits divided into two groups: group 1 underwent capsulorrhaphy on both right and left hips with simple suture using polyglycolic acid absorbable thread, and group 2 underwent capsulorrhaphy with titanium anchors. After a four-week postoperative period, the animals were euthanized and the hip joints were frozen. On the same day of the biomechanical studies, after the hip joints were previously unfrozen, the following parameters were evaluated: rigidity, maximum force, maximum deformity and energy. Results There was no relevant statistical difference in rigidity, maximum force, maximum deformity and energy between the simple suture and anchor groups. Conclusion Through biomechanical analyses, using parameters of rigidity, maximum force, maximum deformity and energy, it has been shown that capsulorrhaphy with simple suture and with anchors has similar results in rabbit hip joints. Level of Evidence II, Prospective Comparative Study. PMID:24453618

  20. Frontoorbital advancement in coronal suture craniosynostosis: a ...

    African Journals Online (AJOL)

    The frontal bone was then removed as indicated. The most lateral aspect of the coronal suture was radically removed with rongeurs, including a part of the greater and lesser wings of the sphenoid bone. The frontal and temporal lobes of the brain were gently repositioned to allow for safe upper orbital osteotomies through ...

  1. Non-suture methods of vascular anastomosis

    NARCIS (Netherlands)

    Zeebregts, CJ; Heijmen, RH; van den Dungen, JJ; van Schilfgaarde, R

    Background: The main aim of performing a vascular anastomosis is to achieve maximal patency rates. An important factor to achieve that goal is to minimize damage to the vessel walls. Sutures inevitably induce vascular wall damage, which influences the healing of the anastomosis. Over time, several

  2. RELAP-7 Closure Correlations

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Berry, R. A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, R. C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, H. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hansel, J. E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Sharpe, J. P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Johns, Russell C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The code is based on the INL’s modern scientific software development framework, MOOSE (Multi-Physics Object Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5’s and TRACE’s capabilities and extends their analysis capabilities for all reactor system simulation scenarios. The RELAP-7 code utilizes the well-posed 7-equation two-phase flow model for compressible two-phase flow. Closure models used in the TRACE code has been reviewed and selected to reflect the progress made during the past decades and provide a basis for the colure correlations implemented in the RELAP-7 code. This document provides a summary on the closure correlations that are currently implemented in the RELAP-7 code. The closure correlations include sub-grid models that describe interactions between the fluids and the flow channel, and interactions between the two phases.

  3. Suture needles in oral surgery: alterations depending on the type and number of sutures.

    Science.gov (United States)

    Torres-Lagares, Daniel; Barranco-Piedra, Sebastian; Rodríguez-Caballero, Angela; Serrera-Figallo, María-Angeles; Segura-Egea, Juan-José; Gutiérrez-Pérez, José-Luis

    2012-01-01

    This study examined whether the number and type of sutures used in oral surgery influence two ad hoc variables (incision plane and displaced area), which are two variables related to whether the suture needle is suitable for the task. Seventy-five TB-15 needles were studied, which were used to suture between zero and three mucosa and/subperiosteal sutures, producing 15 groups with 5 needles in each one. The incision plane and displaced area were measured for each group, which are two variables related to how the needle has worn and altered. Statistical treatment was conducted using the Kruskal-Wallis H test to compare multiple values and the Mann-Whitney U test to compare pairs. A multi-stage regression model was applied with the aim of predicting the changes in the dependent variables based on the number and type of sutures performed. The incision plane ranged from 126.67 to 346.24 µm among the different groups. The displaced area was measured as being between 14 524.83 µm² and 128 311.91 µm². The best predictive model for the incision plane obtained a coefficient of determination (R2) of 0.149, while it reached 0.249 for the displaced area. Subperiosteal sutures held more weighting among the variables studied. Mucosal sutures did not seem to greatly affect needle wear. Observations reported in this paper indicate that the needle should be changed after having performed two subperiosteal sutures, given the wear and change to the incision plane that is produced, which causes the needle's cutting ability to reduce.

  4. Comparison of an all-inside suture technique with traditional pull-out suture and suture anchor repair techniques for flexor digitorum profundus attachment to bone.

    Science.gov (United States)

    Chu, Jennifer Y; Chen, Tony; Awad, Hani A; Elfar, John; Hammert, Warren C

    2013-06-01

    One goal in repairing zone 1 flexor digitorum profundus (FDP) injuries is to create a tendon-bone construct strong enough to allow early rehabilitation while minimizing morbidity. This study compares an all-inside suture repair technique biomechanically with pull-out suture and double-suture anchor repairs. Repairs were performed on 30 cadaver fingers. In all-inside suture repairs (n = 8), the FDP tendon was attached to bone with two 3-0 Ethibond sutures and tied over the dorsal aspect of distal phalanx. Pull-out suture repairs (n = 8) were performed with 2-0 Prolene suture and tied over a dorsal button. There were 2 suture anchor repair groups: Arthrex Micro Corkscrew anchors preloaded with 2-0 FiberWire suture (n = 7) and Depuy Micro Mitek anchors preloaded with 3-0 Orthocord suture (n = 7). Repair constructs were tested using a servohydraulic materials testing system and loaded until the repair lost 75% of its strength. There were no statistically significant differences in tensile stiffness, ultimate load, or work to failure between the repairs. Failure mode was suture stretch and gap formation greater than 2 mm at the repair site for all pull-out suture repairs and for 7 of 8 all-inside suture repairs. Two of the Arthrex Micro Corkscrew repairs and 5 of the Depuy Micro Mitek repairs failed by anchor pull-out. This cadaveric biomechanical study showed no difference in tensile stiffness, ultimate load, and work to failures between an all-inside suture repair technique for zone 1 FDP repairs and previously described pull-out suture and suture anchor repair techniques. The all-inside suture technique also has the advantages of avoiding an external button and the cost of anchors. Therefore, it should be considered as an alternative to other techniques. This study introduces a new FDP reattachment technique that avoids some of the shortcomings of current techniques. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights

  5. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  6. Horizontal running mattress suture modified with intermittent simple loops.

    Science.gov (United States)

    Chacon, Anna H; Shiman, Michael I; Strozier, Narissa; Zaiac, Martin N

    2013-01-01

    Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion.

  7. Printing tattoo effect after use of Dermabond®Prineo® Skin closure system

    Directory of Open Access Journals (Sweden)

    Shabeer Ahmad Wani

    2017-03-01

    Full Text Available Abdominoplasty is a very common procedure in the plastic surgery practice and may lead to a variety of unfavorable results including incision site complications. The surgical adhesives system, which entered into daily practice to replace the need for subcuticular closure for skin, saves time and may have better wound appearance. Dermabond® Prineo® Skin Closure System (Ethicon Inc., Somerville, NJ, USA has two major components: 2–Octyl cyanoacrylate glue and a flexible, self-adhesive polyester mesh. It can be used with or without sutures, and has the added benefit of waterproofing, and microbial resistance. It also saves time. This case describes a male patient who experienced a “printing tattoo” effect following an elective procedure of abdominoplasty and the results after this closure system was used.

  8. European Hernia Society guidelines on the closure of abdominal wall incisions.

    Science.gov (United States)

    Muysoms, F E; Antoniou, S A; Bury, K; Campanelli, G; Conze, J; Cuccurullo, D; de Beaux, A C; Deerenberg, E B; East, B; Fortelny, R H; Gillion, J-F; Henriksen, N A; Israelsson, L; Jairam, A; Jänes, A; Jeekel, J; López-Cano, M; Miserez, M; Morales-Conde, S; Sanders, D L; Simons, M P; Śmietański, M; Venclauskas, L; Berrevoet, F

    2015-02-01

    The material and the surgical technique used to close an abdominal wall incision are important determinants of the risk of developing an incisional hernia. Optimising closure of abdominal wall incisions holds a potential to prevent patients suffering from incisional hernias and for important costs savings in health care. The European Hernia Society formed a Guidelines Development Group to provide guidelines for all surgical specialists who perform abdominal incisions in adult patients on the materials and methods used to close the abdominal wall. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and methodological guidance was taken from Scottish Intercollegiate Guidelines Network (SIGN). The literature search included publications up to April 2014. The guidelines were written using the AGREE II instrument. An update of these guidelines is planned for 2017. For many of the Key Questions that were studied no high quality data was detected. Therefore, some strong recommendations could be made but, for many Key Questions only weak recommendations or no recommendation could be made due to lack of sufficient evidence. To decrease the incidence of incisional hernias it is strongly recommended to utilise a non-midline approach to a laparotomy whenever possible. For elective midline incisions, it is strongly recommended to perform a continuous suturing technique and to avoid the use of rapidly absorbable sutures. It is suggested using a slowly absorbable monofilament suture in a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4/1 is the current recommended method of fascial closure. Currently, no recommendations can be given on the optimal technique to close emergency laparotomy incisions. Prophylactic mesh augmentation appears effective and safe and can be suggested in high

  9. Nevada Test Site closure program

    Energy Technology Data Exchange (ETDEWEB)

    Shenk, D.P.

    1994-08-01

    This report is a summary of the history, design and development, procurement, fabrication, installation and operation of the closures used as containment devices on underground nuclear tests at the Nevada Test Site. It also addresses the closure program mothball and start-up procedures. The Closure Program Document Index and equipment inventories, included as appendices, serve as location directories for future document reference and equipment use.

  10. MNC Subsidiary Closure

    DEFF Research Database (Denmark)

    de Faria, Pedro; Sofka, Wolfgang; Torres Preto, Miguel

    We investigate the consequences of MNC subsidiary closures for employees who lose their jobs. We ask to what degree the foreign knowledge that they were exposed to is valued in their new job. We argue theoretically that this foreign knowledge is both valuable and not readily available in the host...... country but is also distant and therefore difficult to absorb. We predict an inverse u-shaped relationship between the exposure to foreign knowledge and the salary in the new job. We empirically support our predictions for a sample of almost 140,000 affected employees in Portugal from 2002 to 2009....

  11. MNC Subsidiary Closure

    DEFF Research Database (Denmark)

    de Faria, Pedro; Preto, Miguel Torres; Sofka, Wolfgang

    2013-01-01

    We investigate the consequences of MNC subsidiary closures for employees who lose their jobs. We ask to what degree the foreign knowledge that they were exposed to is valued in their new job. We argue theoretically that this foreign knowledge is both valuable and not readily available in the host...... country but is also distant and therefore difficult to absorb. We predict an inverse u-shaped relationship between the exposure to foreign knowledge and the salary in the new job. We empirically support our predictions for a sample of almost 140,000 affected employees in Portugal from 2002 to 2009....

  12. Empirical Correlates of Narrative Closure

    Directory of Open Access Journals (Sweden)

    Tobias Klauk

    2016-06-01

    Full Text Available This paper presents an experimental investigation of the narratological concept of narrative closure. While narrative closure is a well-studied phenomenon in contemporary narratology, it still lacks a serious empirical foundation. In order to fill that lacuna, we performed a controlled rating experiment aimed at validating some of the properties of narrative closure proposed in the narratological literature. Our results suggest that narrative closure is closely related to two connected properties: to the completeness of the text and to questions left open by the text.

  13. Optimal suture materials for contaminated gastrointestinal surgery: does infection influence the decrease of the tensile strength of sutures?

    Science.gov (United States)

    Tanaka, Yoichi; Sadahiro, Sotaro; Ishikawa, Kenji; Suzuki, Toshiyuki; Kamijo, Akemi; Tazume, Seiki; Yasuda, Masanori

    2012-12-01

    Suture materials are selected based on the following factors: absorbable/non-absorbable, monofilament/multifilament, duration with sufficiently high tensile strength, and the tissue to be sutured. Absorbable sutures are hydrolyzed in tissues. However, little is known about the influence of infection on the hydrolysis and decrease in the tensile strength. Four kinds of sutures, i.e., non-absorbable multifilament silk, non-absorbable monofilament polypropylene (Prolene(®)), absorbable multifilament polyglactin 910 (Vicryl(®)), and absorbable monofilament polydioxanone (PDS(®)) were implanted in the back of rats. A suspension of Escherichia coli + Bacteroides fragilis or saline was injected subcutaneously into the contaminated and clean condition groups, respectively. The sutures were removed 1, 2, 4 or 8 weeks after the implantation. There was significantly more severe inflammation macroscopically for the silk sutures under the contaminated conditions (p = 0.03), however, no significant differences were observed among the other three sutures. All 4 kinds of sutures showed a reduction of the tensile strength over time. There were no significant differences in the magnitude of reduction between both the clean and contaminated conditions for any of the sutures. The reduction of the tensile strength with time did not differ significantly between sutures exposed to contaminated and clean conditions, even for the absorbable sutures.

  14. Impact of intra-abdominal absorbable sutures on surgical site infection in gastrointestinal and hepato-biliary-pancreatic surgery: results of a multicenter, randomized, prospective, phase II clinical trial.

    Science.gov (United States)

    Maehara, Yoshihiko; Shirabe, Ken; Kohnoe, Shunji; Emi, Yasunori; Oki, Eiji; Kakeji, Yoshihiro; Baba, Hideo; Ikeda, Masataka; Kobayashi, Michiya; Takayama, Tadatoshi; Natsugoe, Shoji; Haraguchi, Masashi; Yoshida, Kazuhiro; Terashima, Masanori; Sasako, Mitsuru; Yamaue, Hiroki; Kokudo, Norihiro; Uesaka, Katsuhiko; Uemoto, Shinji; Kosuge, Tomoo; Sawa, Yoshiki; Shimada, Mitsuo; Doki, Yuichiro; Yamamoto, Masakazu; Taketomi, Akinobu; Takeuchi, Masahiro; Akazawa, Kouhei; Yamanaka, Takeharu; Shimokawa, Mototsugu

    2017-09-01

    The use of absorbable sutures in wound closure has been shown to reduce the incidence of surgical site infection (SSI); however, there is no evidence that the intra-abdominal use of absorbable rather than silk sutures reduces the incidence of SSI after gastrointestinal surgery. We report the findings of a phase II trial, designed to evaluate the impact of the intra-abdominal use of absorbable sutures on the incidence of SSI. At 19 Japanese hospitals, 1147 patients undergoing elective gastrectomy, colorectal surgery, hepatectomy, or pancreaticoduodenectomy (PD) were randomly assigned to absorbable or silk intra-abdominal suture groups. The primary efficacy endpoint was the incidence of SSI. The secondary efficacy endpoints were the locations of SSI, time to resolution of SSI, length of hospital stay, and the incidence of bile leakage in hepatectomy and pancreatic fistula. The incidence of SSI was 11.3%, 15.5%, 11.3%, and 36.9% after gastrectomy, colorectal surgery, hepatectomy, and PD, respectively. The incidence of SSI was higher in the absorbable suture group than in the silk suture group for all the surgical procedures, but the difference was not significant. The intra-abdominal use of absorbable sutures did not have enough of an effect on the reduction of SSI in this phase II trial to justify the planning of a large-scale phase III trial.

  15. Sandwich wound closure reduces the risk of cerebrospinal fluid leaks in posterior fossa surgery

    Directory of Open Access Journals (Sweden)

    Verena Heymanns

    2016-07-01

    Full Text Available Posterior fossa surgery is demanding and hides a significant number of obstacles starting from the approach to the wound closure. The risk of cerebrospinal fluid (CSF leakage in posterior fossa surgery given in the literature is around 8%. The present study aims to introduce a sandwich closure of the dura in posterior fossa surgery, which reduces significantly the number of CSF leaks (3.8% in the patients treated in our department. Three hundred and ten patients treated in our hospital in the years 2009-2013 for posterior fossa pathologies were retrospectively evaluated. The dura closure method was as following: lyophilized dura put under the dura and sealed with fibrin glue and sutures, dura adapting stitches, TachoSil® (Takeda Pharma A/S, Roskilde, Denmark, Gelfoam® (Pfizer Inc., New York, NY, USA and polymethylmethacrylate (osteoclastic craniotomy. The incidence of postsurgical complications associated with the dural closure like CSF leakage, infections, bleeding is evaluated. Only 3.8% of patients developed CSF leakage and only 0.5% needed a second surgery for CSF leakage closure. Two percent had a cerebellar bleeding with no need for re-operation and 3% had a wound infection treated with antibiotics. The sandwich wound closure we are applying for posterior fossa surgery in our patients correlates with a significant reduction of CSF leaks compared to the literature.

  16. Effectiveness of a new gelatin sealant system for dural closure.

    Science.gov (United States)

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P  =  0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P  =  0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  17. FINAL CLOSURE PLAN SURFACE IMPOUNDMENTS CLOSURE, SITE 300

    Energy Technology Data Exchange (ETDEWEB)

    Lane, J E; Scott, J E; Mathews, S E

    2004-09-29

    Lawrence Livermore National Laboratory of the University of California (LLNL) operates two Class II surface impoundments that store wastewater that is discharged from a number of buildings located on the Site 300 Facility (Site 300). The wastewater is the by-product of explosives processing. Reduction in the volume of water discharged from these buildings over the past several years has significantly reduced the wastewater storage needs. In addition, the impoundments were constructed in 1984, and the high-density polyethylene (HDPE) geomembrane liners are nearing the end of their service life. The purpose of this project is to clean close the surface impoundments and provide new wastewater storage using portable, above ground storage tanks at six locations. The tanks will be installed prior to closure of the impoundments and will include heaters for allowing evaporation during relatively cool weather. Golder Associates (Golder) has prepared this Final Closure Plan (Closure Plan) on behalf of LLNL to address construction associated with the clean closure of the impoundments. This Closure Plan complies with State Water Resources Control Board (SWRCB) Section 21400 of the California Code of Regulations Title 27 (27 CCR {section}21400). As required by these regulations and guidance, this Plan provides the following information: (1) A site characterization, including the site location, history, current operations, and geology and hydrogeology; (2) The regulatory requirements relevant to clean closure of the impoundments; (3) The closure procedures; and, (4) The procedures for validation and documentation of clean closure.

  18. Suture locking of isolated internal locking knotless suture anchors is not affected by bone quality

    Directory of Open Access Journals (Sweden)

    Woodmass JM

    2015-06-01

    Full Text Available Jarret M Woodmass,1 Graeme Matthewson,1 Yohei Ono,1,2 Aaron J Bois,1 Richard S Boorman,1 Ian KY Lo,1 Gail M Thornton1,31Department of Surgery, Section of Orthopaedic Surgery, McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada; 2Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan; 3Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada Purpose: The purpose of this study was to evaluate the mechanical performance of different suture locking mechanisms including: i interference fit between the anchor and the bone (eg, 4.5 mm PushLock, 5.5 mm SwiveLock, ii internal locking mechanism within the anchor itself (eg, 5.5 mm SpeedScrew, or iii a combination of interference fit and internal locking (eg, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S. Methods: Anchors were tested in foam blocks representing normal (20/8 foam or osteopenic (8/8 foam bone, using standard suture loops pulled in-line with the anchor to isolate suture locking. Mechanical testing included cyclic testing for 500 cycles from 10 N to 60 N at 60 mm/min, followed by failure testing at 60 mm/min. Displacement after 500 cycles at 60 N, number of cycles at 3 mm displacement, load at 3 mm displacement, and maximum load were evaluated. Results: Comparing 8/8 foam to 20/8 foam, load at 3 mm displacement and maximum load were significantly decreased (P<0.05 with decreased bone quality for anchors that, even in part, relied on an interference fit suture locking mechanism (ie, 4.5 mm PushLock, 5.5 mm SwiveLock, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S. Bone quality did not affect the mechanical performance of 5.5 mm SpeedScrew anchors which have an isolated internal locking mechanism. Conclusion: The mechanical performance of anchors that relied, even in part, on interference fit were affected by bone quality. Isolated internal locking knotless suture anchors functioned independently of bone quality

  19. Skin tension related to tension reduction sutures.

    Science.gov (United States)

    Hwang, Kun; Kim, Han Joon; Kim, Kyung Yong; Han, Seung Ho; Hwang, Se Jin

    2015-01-01

    The aim of this study was to compare the skin tension of several fascial/subcutaneous tensile reduction sutures. Six upper limbs and 8 lower limbs of 4 fresh cadavers were used. At the deltoid area (10 cm below the palpable acromion) and lateral thigh (midpoint from the palpable greater trochanter to the lateral border of the patella), and within a 3 × 6-cm fusiform area of skin, subcutaneous tissue defects were created. At the midpoint of the defect, a no. 5 silk suture was passed through the dermis at a 5-mm margin of the defect, and the defect was approximated. The initial tension to approximate the margins was measured using a tensiometer.The tension needed to approximate skin without any tension reduction suture (S) was 6.5 ± 4.6 N (Newton). The tensions needed to approximate superficial fascia (SF) and deep fascia (DF) were 7.8 ± 3.4 N and 10.3 ± 5.1 N, respectively. The tension needed to approximate the skin after approximating the SF was 4.1 ± 3.4 N. The tension needed to approximate the skin after approximating the DF was 4.9 ± 4.0 N. The tension reduction effect of approximating the SF was 38.8 ± 16.4% (2.4 ± 1.5 N, P = 0.000 [ANOVA, Scheffé]). The tension reduction effect of approximating the DF was 25.2% ± 21.9% (1.5 ± 1.4 N, P = 0.001 [ANOVA, Scheffé]). The reason for this is thought to be that the SF is located closely to the skin unlike the DF. The results of this study might be a basis for tension reduction sutures.

  20. Achondroplasia and multiple-suture craniosynostosis.

    Science.gov (United States)

    Albino, Frank P; Wood, Benjamin C; Oluigbo, Chima O; Lee, Angela C; Oh, Albert K; Rogers, Gary F

    2015-01-01

    Genetic mutations in the fibroblast growth factor receptor 3 gene may lead to achondroplasia or syndromic forms of craniosynostosis. Despite sharing a common genetic basis, craniosynostosis has rarely been described in cases of confirmed achondroplasia. We report an infant with achondroplasia who developed progressive multiple-suture craniosynostosis to discuss the genetic link between these clinical entities and to describe the technical challenges associated with the operative management.

  1. Knotless Suture Anchor With Suture Tape Quadriceps Tendon Repair Is Biomechanically Superior to Transosseous and Traditional Suture Anchor-Based Repairs in a Cadaveric Model.

    Science.gov (United States)

    Kindya, Michael C; Konicek, John; Rizzi, Angelo; Komatsu, David E; Paci, James M

    2017-01-01

    To compare the biomechanical properties of a knotless suture anchor with suture tape quadriceps tendon repair technique with transosseous and suture anchor repair techniques. Twenty matched pairs of cadaveric knees underwent a quadriceps tendon avulsion followed by repair via the use of transosseous tunnels with #2 high-strength sutures, 5.5-mm biocomposite fully threaded suture anchors with #2 high-strength sutures, or 4.75-mm biocomposite knotless suture anchors with suture tape. Ten knees were repaired via transosseous repair and 10 via fully threaded suture anchor repair, and their matched specimens were repaired with suture tape and knotless anchors. Biomechanical analysis included displacement during cyclic loading over 250 cycles, construct stiffness, ultimate load to failure, and failure mode analysis. Compared with transosseous repairs, quadriceps tendons repaired with knotless suture tape demonstrated significantly less displacement during cyclic loading (cycles 1-20 3.6 ± 1.3 vs 6.3 ± 1.9 mm, P = .003; cycles 20-250 2.0 ± 0.4 vs 3.1 ± 0.9 mm, P = .011), improved construct stiffness (67 ± 25 vs 26 ± 12 N/mm, P = .001), and greater ultimate load to failure (616 ± 149 vs 413 ± 107 N, P = .004). Our repair technique also demonstrated improved biomechanical parameters compared with fully threaded suture anchor repair in initial displacement during cyclic loading (cycles 1-20 3.0 ± 0.8 vs 5.1 ± 0.9 mm, P suture anchor with suture tape repair technique is biomechanically superior in cyclic displacement, construct stiffness, and ultimate load to failure compared with transosseous and fully threaded suture anchor techniques in cadaveric specimens. The demonstration that our repair technique is biomechanically superior to previously described techniques in a cadaveric setting suggests that consideration should be given to this technique. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Perturbed airway closure

    Science.gov (United States)

    Grotberg, James B.; Halpern, David

    1998-11-01

    The small airways of the lungs are lined with a thin viscous film. A surface-tension driven instability at the air-liquid interface may induce the formation of a liquid bridge blocking airflow if there is sufficient fluid within the film. As a result of the pressures generated within the non-uniform film, the airway wall may also collapse. These instabilities often occur in premature neonates who do not produce sufficient quantities of surfactant. Often, they are placed in ventilators to diminish the risk of airway closure. Two fundamental parameters are the frequency of the ventilation and the tidal volume of the delivered gas. In the current study, we consider the effect of an oscillatory shear stress impinged by the air on a thin film coating a single compliant tube. Nonlinear evolution equations are derived for the film thickness and the wall position. Numerical solutions show that the oscillatory shear stress can saturate the growth of a disturbance at the air-liquid interface. For a given film thickness, there is a critical frequency, dependent on wall parameters, above which closure does not occur when forced by oscillatory shear but will close when unforced.

  3. Laparoscopic ventral hernia repair: outcomes in primary versus incisional hernias: no effect of defect closure.

    Science.gov (United States)

    Lambrecht, J R; Vaktskjold, A; Trondsen, E; Øyen, O M; Reiertsen, O

    2015-06-01

    Supposing divergent aetiology, we found it interesting to investigate outcomes between primary (PH) versus incisional (IH) hernias. In addition, we wanted to analyse the effect of defect closure and mesh fixation techniques. 37 patients with PH and 70 with IH were enrolled in a prospective cohort-study, treated with laparoscopic ventral hernia repair (LVHR) and randomised to ± transfascial sutures. In addition, we analysed results from a retrospective study with 36 PH and 51 IH patients. Mean follow-up time was 38 months in the prospective study and 27 months in the retrospective study. 35 % of PH's and 10 % of IH's were recurrences after previous suture repair. No late infections or mesh removals occurred. Recurrence rates in the prospective study were 0 vs. 4.3 % (p = 0.55) and the complication rates were 16 vs. 27 % (p = 0.24) in favour of the PH cohort. The IH group had a mesh protrusion rate of 13 vs. 5 % in the PH group (p = 0.32), and significantly (p hernias and adhesion score, longer operating time (100 vs. 79 min) and admission time (2.8 vs. 1.6 days). Closure of the hernia defect did not influence rate of seroma, pain at 2 months, protrusion or recurrence. An overall increased complication rate was seen after defect closure (OR 3.42; CI 1.25-9.33). With PH, in comparison to IH treated with LVHR, no differences were observed regarding recurrence, protrusion or complication rates. Defect closure (raphe), when using absorbable suture, did not benefit long-term outcomes and caused a higher overall complication rate. (ClinicalTrials.gov number: NCT00455299).

  4. [Suture tip plasty using an endonasal approach].

    Science.gov (United States)

    Tasman, A-J; Palma, P

    2010-09-01

    Over the last two decades, the use of the external approach for primary and secondary rhinoplasties has become increasingly popular. This article illustrates the versatility of endonasal techniques for the correction of nasal tip deformities on the basis of four cases. The approach to the nasal tip and the chosen technique as used in 100 consecutive rhinoplasties were reviewed. For primary and revision tip plasty, endonasal approaches were used in 81% of cases. Preferred incisions were the infracartilaginous approach and the transfixion incision. Using these approaches, correction of the tip was achieved by using sutures to reposition and reshape the alar cartilages and the columella without grafts to the nasal tip in most cases. Nasal tip plasty via endonasal approaches using sutures is technically more challenging compared to the external approach with its superior exposure. This drawback is outweighed by less operating time and faster patient recovery. Contrary to the general trend, the authors believe that endonasal tip plasty techniques using sutures can obviate the external approach and grafts in many cases and should form an integral part of the rhino-surgeon's repertoire.

  5. Insertion force in manual and robotic corneal suturing.

    Science.gov (United States)

    Yang, Yang; Xu, Cunliang; Deng, Shijing; Xiao, Jingjing

    2012-03-01

    Due to differences in corneal grafting microsurgery between manual and robotic suturing, new challenges have arisen in testing the insertion force and torque of corneal tissue acting on suturing needles in order to guarantee successful completion of surgical procedures. In order to measure the force during the insertion operation, from the needle entering the cornea through the entry point until the puncturing of the exit point along the circular trajectory, a force measurement system was established, including fresh porcine cornea, a corneal-suturing robot, a circular needle, a micro-forceps manipulator with a force transducer, a computer with a data acquisition board and a medical microscope. The force values in the needle coordinate frames were obtained on the basis of a sensor coordinate frame through D-H coordinate transformation, and an index is proposed here to evaluate the insertion performance. Experiments on both manual and robotic suturing were carried out for comparison. The scale and changes of the needle insertion force were obtained using two different suturing methods. The maximal tangent force in robotic suturing is a little larger than in manual suturing, and the maximal resultant force in robotic suturing is somewhat smaller. Although the difference is not very significant, robotic suturing performs in a more stable way. Moreover, the performance evaluation index M(dmax) (the maximum of square root of the quadratic sum of torque components M(OX) and M(OY)) in robotic suturing is much smaller than that in manual suturing. The force measurement system has been verified to be feasible through experimentation. Compared with conventional manual surgery, robotic suturing has some advantages: more stable suturing, smaller distortion torque and fewer invasions to the corneal tissue, showing that its application in minimally invasive surgery is practical. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Suture With Resorbable Cones: Histology and Physico-Mechanical Features.

    Science.gov (United States)

    Consiglio, Fabio; Pizzamiglio, Roberto; Parodi, Pier Camillo; De Biasio, Fabrizio; Machin, Pier Nicola; Di Loreto, Carla; Gamboa, Mabel

    2016-03-01

    Silhouette Sutures (Kolster Methods, Inc., Corona, CA) exhibit different biological characteristics at various time points after their placement. The goals of this study were to understand the biological reactions of Silhouette Sutures in human tissues at different time intervals and to determine the index of resistance of the sutures in subcutaneous tissue. Histologic examination was performed on section soft tissue containing the sutures at 1 month, 3 months, 6 months, and 1 year after suture placement. The study comprised 8 patients, each of whom received 4 sutures in the lower abdomen under local anesthesia. The sutures were placed exactly 1 month, 3 months, 6 months, and 1 year before planned post-bariatric abdominal surgery. Dynamometric evaluation was performed on a never-used suture and on sutures removed from 1 year after placement. The scar process around the threads was also examined. A progressive increase in scar tissue around the sutures was observed. One year after placement, there was a reduction of 16.7% in yield and tensile strength and a reduction of 14.29% in elongation at break, relative to the never-used suture. By 1 year, the cones in polylactic and glycolic acids had been replaced by scar tissue. Fibrous tissue around the sutures increased progressively over time, and was most prominent at the level of the nodes. Cones were completely resorbed within 6 months. A reduction in the index of resistance of the suspension sutures occurred over 1 year. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  7. 40 CFR 265.1102 - Closure and post-closure care.

    Science.gov (United States)

    2010-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Containment Buildings § 265.1102 Closure and post-closure care. (a) At closure of a containment building, the owner or operator must remove or decontaminate all waste residues... applies. The closure plan, closure activities, cost estimates for closure, and financial responsibility...

  8. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone.

    Science.gov (United States)

    Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y

    2016-06-01

    This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone

  9. Effect of the number of suture throws on the biomechanical characteristics of the suture-tendon construct.

    Science.gov (United States)

    Hong, Chih-Kai; Lin, Cheng-Li; Chang, Chih-Hsun; Jou, I-Ming; Su, Wei-Ren

    2014-12-01

    We aimed to investigate the effect of the number of suture throws on biomechanical characteristics of the suture-tendon construct for 3 currently used suture configurations in this ex vivo biomechanical study. Three stitch configurations-the Krackow stitch, the locking SpeedWhip (LSW) stitch, and the modified finger trap (MFT) suture-were assessed with 3, 5, and 7 throws using porcine flexor profundus tendons randomly divided into 9 groups of 11 specimens. The Krackow stitch and MFT suture were completed with nonabsorbable No. 2 braided sutures, whereas the LSW stitch was completed with loops of nonabsorbable No. 2 braided sutures. Each tendon was pretensioned to 100 N for 3 cycles and then cyclically loaded to 200 N for 200 cycles. Finally, each tendon was loaded to failure. Percent elongation, load to failure, and mode of failure for each suture-tendon construct were measured. After being pretensioned, there were no significant differences in the elongation between different suture throws in the LSW and MFT suture groups (P = .38 and P = .34, respectively). The elongation of the Krackow 7-throw suture group was significantly greater than that of the 5-throw (P = .01) and 3-throw groups (P = .03). After cyclic loading, there was no significant difference in the elongation of each suture technique with respect to different suture throws. The elongation after 200 loading cycles of the MFT sutures was significantly less than that of the Krackow and LSW sutures for all throws. The load to failure and cross-sectional area (43.1 ± 4.6 mm(2); P = .398) were not significantly different across all groups. This ex vivo biomechanical study showed that there are no significant differences in elongation after cyclic loading and load to failure among the various suture throws for the 3 types of sutures investigated. CLINICAL  The 3-suture throw configuration may provide sufficient fixation of the tendon graft regarding biomechanical characteristics of elongation

  10. Comparison of a new multifilament stainless steel suture with frequently used sutures for flexor tendon repair.

    Science.gov (United States)

    McDonald, Erik; Gordon, Joshua A; Buckley, Jenni M; Gordon, Leonard

    2011-06-01

    To investigate the mechanical properties of some common suture materials currently in use and compare them with a new multifilament stainless steel suture. We investigated the mechanical properties of 3-0 and 4-0 Fiberwire, 3-0 Supramid, 3-0 Ethibond, and a new 3-0 and 4-0 multifilament stainless steel suture. All suture material was tested in a knotted configuration and all but the Supramid was tested in an unknotted configuration. We measured the load, elongation at failure, and stiffness during both tests. The 4-0 multifilament stainless steel showed the least elongation, whereas the 3-0 multifilament stainless steel withstood the highest load of any material in both the knotted and unknotted tests. There was no difference in stiffness between the 3-0 and 4-0 multifilament stainless steel when untied; however, the 3-0 multifilament stainless steel was stiffer when tied. Soaking in a saline solution had no significant effect on the ultimate load, elongation at failure, or stiffness of any of the sutures. The 3-0 Fiberwire and 3-0 Ethibond required at least 5 throws to resist untying. Multifilament stainless steel exhibited promising mechanical advantages over the other sutures tested. More research is needed to determine how this material will affect the clinical outcomes of primary flexor tendon repair. With a secure attachment to the tendon, the multifilament stainless steel's lower elongation and better knot-holding ability may result in a higher force to produce a 2-mm gap and a higher ultimate tensile strength in a tendon repair. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. BMP9 induces osteogenesis and adipogenesis in the immortalized human cranial suture progenitors from the patent sutures of craniosynostosis patients.

    Science.gov (United States)

    Song, Dongzhe; Zhang, Fugui; Reid, Russell R; Ye, Jixing; Wei, Qiang; Liao, Junyi; Zou, Yulong; Fan, Jiaming; Ma, Chao; Hu, Xue; Qu, Xiangyang; Chen, Liqun; Li, Li; Yu, Yichun; Yu, Xinyi; Zhang, Zhicai; Zhao, Chen; Zeng, Zongyue; Zhang, Ruyi; Yan, Shujuan; Wu, Tingting; Wu, Xingye; Shu, Yi; Lei, Jiayan; Li, Yasha; Zhang, Wenwen; Wang, Jia; Lee, Michael J; Wolf, Jennifer Moriatis; Huang, Dingming; He, Tong-Chuan

    2017-11-01

    The cranial suture complex is a heterogeneous tissue consisting of osteogenic progenitor cells and mesenchymal stem cells (MSCs) from bone marrow and suture mesenchyme. The fusion of cranial sutures is a highly coordinated and tightly regulated process during development. Craniosynostosis is a congenital malformation caused by premature fusion of cranial sutures. While the progenitor cells derived from the cranial suture complex should prove valuable for studying the molecular mechanisms underlying suture development and pathogenic premature suture fusion, primary human cranial suture progenitors (SuPs) have limited life span and gradually lose osteoblastic ability over passages. To overcome technical challenges in maintaining sufficient and long-term culture of SuPs for suture biology studies, we establish and characterize the reversibly immortalized human cranial suture progenitors (iSuPs). Using a reversible immortalization system expressing SV40 T flanked with FRT sites, we demonstrate that primary human suture progenitor cells derived from the patent sutures of craniosynostosis patients can be efficiently immortalized. The iSuPs maintain long-term proliferative activity, express most of the consensus MSC markers and can differentiate into osteogenic and adipogenic lineages upon BMP9 stimulation in vitro and in vivo. The removal of SV40 T antigen by FLP recombinase results in a decrease in cell proliferation and an increase in the endogenous osteogenic and adipogenic capability in the iSuPs. Therefore, the iSuPs should be a valuable resource to study suture development, intramembranous ossification and the pathogenesis of craniosynostosis, as well as to explore cranial bone tissue engineering. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  12. Unidirectional barbed suture versus standard monofilament for urethrovesical anastomosis during robotic assisted laparoscopic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Marc Manganiello

    2012-02-01

    Full Text Available PURPOSE: V-LocTM180 (Covidien Healthcare, Mansfield, MA is a new unidirectional barbed suture that may reduce loss of tension during a running closure. We evaluated the use of the barbed suture for urethrovesical anastomosis (UVA during robotic assisted laparoscopic prostatectomy (RALP. Time to completion of UVA, post-operative anastomotic leak rate, and urinary incontinence were compared in patients undergoing UVA with 3-0 unidirectional-barbed suture vs. 3-0 MonocrylTM (Ethicon, Somerville, NJ. MATERIALS AND METHODS: Data were prospectively collected for 70 consecutive patients undergoing RALP for prostate cancer between November 2009 and October 2010. In the first 35 patients, the UVA was performed using a modified running van Velthoven anastomosis technique using two separate 3-0 monofilament sutures. In the subsequent 35 patients, the UVA was performed using two running novel unidirectional barbed sutures. At 7-12 days postoperatively, all patients were evaluated with a cystogram to determine anastomotic integrity. Urinary incontinence was assessed at two months and five months by total daily pad usage. Clinical symptoms suggestive of bladder neck contracture were elicited. RESULTS: Age, PSA, Gleason score, prostate size, estimated blood loss, body mass index, and clinical and pathologic stage between the 2 groups were similar. Comparing the monofilament group and V-LocTM180 cohorts, average time to complete the anastomosis was similar (27.4 vs. 26.4 minutes, p = 0.73 as was the rate of urinary extravasation on cystogram (5.7 % vs. 8.6%, p = 0.65. There were no symptomatic bladder neck contractures noted at 5 months of follow-up. At 2 months, the percentage of patients using 2 or more pads per day was lower in the V-LocTM180 cohort (24% vs. 44%, p < 0.02. At 5 months, this difference was no longer evident. CONCLUSIONS: Time to complete the UVA was similar in the intervention and control groups. Rates of urine leak were also comparable

  13. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  14. The frontosphenoidal suture: fetal development and phenotype of its synostosis

    Energy Technology Data Exchange (ETDEWEB)

    Mathijssen, Irene M.J.; Meulen, Jacques J.N.M. van der; Adrichem, Leon N.A. van; Vaandrager, J.M.; Vermeij-Keers, Christl [Erasmus MC, University Medical Centre, Department of Plastic and Reconstructive Surgery, Rotterdam (Netherlands); Hulst, Rene R.W.J. van der [University Hospital Maastricht, Department of Plastic and Reconstructive Surgery, Maastricht (Netherlands); Lequin, Maarten H. [Erasmus MC, University Medical Centre, Department of Radiology, Rotterdam (Netherlands)

    2008-04-15

    Isolated synostosis of the frontosphenoidal suture is very rare and difficult to diagnose. Little has been reported on the clinical presentation and fetal development of this suture. To understand the development of the frontosphenoidal suture and the outcome of its synostosis. We studied the normal fetal development of the frontosphenoidal suture in dry human skulls and the clinical features of four patients with isolated synostosis of the frontosphenoidal suture. The frontosphenoidal suture develops relatively late during the second trimester of pregnancy, which explains the mild phenotype when there is synostosis. This rare craniosynostosis results in a deformity that causes recession of the lateral part of the frontal bone and supraorbital rim, with minimal facial asymmetry. Three-dimensional CT is the best examination to confirm the diagnosis. Isolated frontosphenoidal synostosis should be considered in patients with unilateral flattening of the forehead at birth that does not improve within the first few months of life. (orig.)

  15. Strabismus Surgery Reoperation Rates With Adjustable and Conventional Sutures.

    Science.gov (United States)

    Leffler, Christopher T; Vaziri, Kamyar; Cavuoto, Kara M; McKeown, Craig A; Schwartz, Stephen G; Kishor, Krishna S; Pariyadath, Allison

    2015-08-01

    To determine the association of strabismus surgery reoperation rates with adjustable or conventional sutures. Retrospective cross-sectional study. setting: Review of a large national private insurance database. Adults aged 18-89 having strabismus surgery between 2007 and 2011. Adjustable vs conventional suture strabismus surgery. Reoperation rate in the first postoperative year. Overall, 526 of 6178 surgical patients had a reoperation (8.5%). Reoperations were performed after 8.1% of adjustable suture surgeries and after 8.6% of conventional suture surgeries (P = .57). Of the 4357 horizontal muscle surgeries, reoperations were performed after 5.8% of adjustable suture surgeries, and after 7.8% of conventional suture surgeries (P = .02). Of the 1072 vertical muscle surgeries, reoperations were performed after 15.2% of adjustable suture surgeries and after 10.4% of conventional suture surgeries (P = .05). Younger age (18-39 years) was associated with a lower reoperation rate (P ≤ .02). The significant multivariable predictors of reoperation for horizontal surgery were adjustable sutures (odds ratio [OR] 0.69, 95% confidence interval 0.52-0.91), monocular deviation (OR 0.64), complex surgery (OR 1.63), and unilateral surgery on 2 horizontal muscles (OR 0.70, all P ≤ .01). Adjustable sutures were not significantly associated with reoperation rates after vertical muscle surgery (multivariable OR 1.45, P = .07). Adjustable sutures were associated with significantly fewer reoperations for horizontal muscle surgery. Adjustable sutures tended to be associated with more reoperations for vertical muscle surgery, but this observation was not statistically significant in the primary analysis after controlling for age. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Understanding the logic of common suturing techniques in dermatologic surgery

    OpenAIRE

    Yazdani Abyaneh, Mohammad-Ali; Levitt, Jacob O

    2015-01-01

    Although most trainees in dermatology learn that different suturing techniques are designated for a specific purpose (i.e., certain functional and cosmetic outcomes), students often have a difficult time visualizing how a given suture functions in its designated capacity. In this article, we address the logic behind the most common suturing techniques in dermatologic surgery, including the direction and magnitude of their pulling force with respect to the wound edges and the ensuing displacem...

  17. New "loop" suture for FDP zone I injuries.

    Science.gov (United States)

    Kapickis, Martins

    2009-09-01

    There are many methods describing distal juncture fixation techniques of the injured flexor digitorum profundus (FDP) or flexor tendon graft. We have noted a tendency in the surgical repair of tissues toward the more expensive and technology-dependent methods. New suture type was developed to find better FDP distal juncture suture not indulging into expensive technology-dependent techniques. The positive aspect of the most popular Bunnell pullout technique is eventual removal of the suture. The negative aspect is necessity to use tie over button to secure the end of the tendon in the bone canal and thus externalizing suture. This can be complicated with maceration, decubitus, and infection. In addition, any device secured to the finger nail can be caught by external objects. We propose buttonless method of the tendon-to-bone fixation. The only negative aspect is retaining suture. Suture is easy to perform and cheaper than any of the anchor sutures. Twelve patients were included in this preliminary study. Seven patients had acute FDP tendon zone I bone juncture injuries. Five patients had second stage flexor tendon reconstruction with tendon grafts. No infections, ruptures of the FDP or nail growth disturbances were noted. Three patients presented with slight DIP joint flexion contracture. One patient had "mallet" deformity. Our tendon-to-bone fixation is easy to perform. It is as cheap as standard Bunnell fixation and excludes complications encountered in standard pullout sutures. Although bone suture anchors with modified Becker core suture are superior in tensile strength to 2-stranded sutures, many hand surgeons are limited by the price of the bone anchors and can find our suture more affordable.

  18. A study of sutural bones in Gujarati (Indian) crania.

    Science.gov (United States)

    Pal, G P; Bhagwat, S S; Routal, R V

    1986-03-01

    370 adult crania were examined to find the incidence of sutural bones in Gujarati (Indian) crania and to compare it with other populations to establish the distance between them. The mean measure of difference between Indian and other populations was statistically significant. Comparison of cranial capacity in skulls with and without sutural bones showed no significant difference, and this is interpreted as indicating that sutural bones are not formed secondary to stress.

  19. Folate receptors and neural tube closure.

    Science.gov (United States)

    Saitsu, Hirotomo

    2017-09-01

    Neural tube defects (NTD) are among the most common human congenital malformations, affecting 0.5-8.0/1000 of live births. Human clinical trials have shown that periconceptional folate supplementation significantly decreases the occurrence of NTD in offspring. However, the mechanism by which folate acts on NTD remains largely unknown. Folate receptor (Folr) is one of the three membrane proteins that mediate cellular uptake of folates. Recent studies suggest that mouse Folr1 (formerly referred to as Fbp1) is essential for neural tube closure. Therefore, we examined spatial and temporal expression patterns of Folr1 in developing mouse embryos, showing a close association between Folr1 and anterior neural tube closure. Transient transgenic analysis was performed using lacZ as a reporter; we identified a 1.1-kb enhancer that directs lacZ expression in the neural tube and optic vesicle in a manner that is similar to endogenous Folr1. The 1.1-kb enhancer sequences were highly conserved between humans and mice, suggesting that human FOLR1 is associated with anterior neural tube closure in humans. Several experimental studies in mice and human epidemiological and genetics studies have suggested that folate receptor abnormalities are involved in a portion of human NTDs, although the solo defect of FOLR1 did not cause NTD. © 2017 Japanese Teratology Society.

  20. Visual Measurement of Suture Strain for Robotic Surgery

    Directory of Open Access Journals (Sweden)

    John Martell

    2011-01-01

    Full Text Available Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

  1. Visual measurement of suture strain for robotic surgery.

    Science.gov (United States)

    Martell, John; Elmer, Thomas; Gopalsami, Nachappa; Park, Young Soo

    2011-01-01

    Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

  2. Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy

    OpenAIRE

    Sull, Alan; Inceoglu, Serkan; August, Alicia; Gregorius, Stephen; Wongworawat, Montri D.

    2016-01-01

    Background: Barbed suture use has become more popular as technology and materials have advanced. Minimal data exist regarding performance of the 2 commercially available products, V-LocTM and StratafixTM in tendon repairs. The purpose of this study was to compare gap resistance and ultimate tensile strength of both suture materials and nonbarbed suture in a porcine ex vivo model. Methods: Porcine flexor tendons were harvested and divided into 3 groups of 10 of varying suture material (3-0 PDS...

  3. Cyclic loading comparison of Bio-SutureTak-#2 FiberWire and Bio Mini-Revo-#2 Hi-Fi suture anchor-sutures in cadaveric scapulae.

    Science.gov (United States)

    Sparks, Brad S; Nyland, John; Nawab, Akbar; Blackburn, Ethan; Krupp, Ryan; Burden, Robert

    2008-03-01

    This study compared tap-in Bio-SutureTak suture anchor-#2 FiberWire suture (Group 1) and screw-in Bio Mini-Revo suture anchor-#2 Hi-Fi suture (Group 2) fixation in the glenoid region of interest for Bankart repair, in addition to evaluation of isolated suture loop biomechanical properties under progressive incremental cyclic loads. With knowledge of glenoid apparent bone mineral density (BMD), implant preparation and fit characteristics, and following application of a light manual tensile load, the primary investigator scored each specimen for perceived within group biomechanical test performance using a 0-10 point modified visual analog scale. After scoring, 12 paired constructs were placed in a servo hydraulic device clamp, preloaded to 25 N, and cycled between 25 and 50 Hz with a 25 N load increase every 25 cycles. Group 2 withstood greater load (104.1 +/- 56 vs. 70 +/- 36.9 N, P = 0.04) and displaced more at failure (13 +/- 4.5 vs. 8.6 +/- 3.3 mm, P = 0.04). All Group 1 specimens failed prior to reaching 150 N, whereas 25% of Group 2 specimens (n = 3) failed at 200 N. All specimens failed by anchor pullout except for three Group 2 specimens that failed by eyelet breakage at 200 N. Isolated suture testing revealed that Group 1 sutures displaced less at each cyclic load (P = 0.028) and withstood greater failure loads (P = 0.028) than that of Group 2 sutures. Group 2 constructs displayed moderately strong relationships between perceived within group biomechanical test performance and ultimate load (r (2) = 0.55) and displacement at failure (r (2) = 0.67). Group 1 did not display significant relationships. Similar biomechanical performance between 50 and 125 N, greater load at failure, and superior biomechanical test prediction accuracy suggest that the screw-in type Bio Mini-Revo suture anchor-#2 Hi-Fi suture combination may be preferred for Bankart lesion repair in low apparent BMD glenoid processes. The #2 Hi-Fi suture, however, allowed significantly greater

  4. Suture-Only Repair Versus Suture Anchor–Augmented Repair for Achilles Tendon Ruptures With a Short Distal Stump

    Science.gov (United States)

    Boin, Michael A.; Dorweiler, Matthew A.; McMellen, Christopher J.; Gould, Gregory C.; Laughlin, Richard T.

    2017-01-01

    Background: Chronic noninsertional Achilles tendinosis can result in an acute Achilles tendon rupture with a short distal stump. In such tendon ruptures, there is a limited amount of adequate tissue that can hold suture, thus presenting a challenge for surgeons who elect to treat the rupture operatively. Hypothesis: Adding suture anchors to the repair construct may result in biomechanically stronger repairs compared with a suture-only technique. Study Design: Controlled laboratory study. Methods: Nine paired Achilles-calcaneus complexes were harvested from cadavers. An artificial Achilles rupture was created 2 cm proximal to the insertion on the calcaneus. One specimen from each cadaver was assigned to a suture-only or a suture anchor–augmented repair. The contralateral specimen of the same cadaver received the opposing repair. Cyclic testing was then performed at 10 to 100 N for 2000 cycles, and load-to-failure testing was performed at 0.2 mm/s. This was followed by analysis of repair displacement, gapping at repair site, peak load to failure, and failure mode. Results: The suture anchor–augmented repair exhibited a 116% lower displacement compared with the suture-only repair (mean ± SD, 1.54 ± 1.13 vs 3.33 ± 1.47 mm, respectively; P suture anchor–augmented repair also exhibited a 45% greater load to failure compared with the suture-only repair (303.50 ± 102.81 vs 209.09 ± 48.12 N, respectively; P Suture anchor–augmented repairs performed on acute Achilles tendon ruptures with a short distal stump are biomechanically stronger than suture-only repairs. Clinical Relevance: Our results support the use of suture anchor–augmented repairs for a biomechanically stronger construct in Achilles tendon ruptures with a short distal stump. Biomechanically stronger repairs may lead to less tendon repair gapping and failure, increasing the ability to start early active rehabilitation protocols and thus improving patient outcomes. PMID:28203592

  5. Usefulness of continuous suture using short-thread double-armed micro-suture for cerebral vascular anastomosis

    OpenAIRE

    Sei Haga; Shinji Nagata

    2014-01-01

    Background: When microvascular anastomosis is performed in a deep, narrow operating field, securing space to throw knots is difficult. To simplify the procedure and avoid obstruction of the anastomosis, we use a continuous suturing with short-thread double-armed micro-suture. Methods: Sixty-four patients (38 cerebral revasculazation, 16 moyamoya disease, and 10 aneurysm surgery) undergoing microvaucular anastomosis were included. During anastomosis, a continuous suture was placed with sho...

  6. Primary closure of inadvertent durotomies utilizing the U-Clip in minimally invasive spinal surgery.

    Science.gov (United States)

    Song, Debbie; Park, Paul

    2011-12-15

    Retrospective clinical cohort study. To examine performance of the U-Clip for the closure of inadvertent durotomy occurring during minimally invasive spinal surgery. Primary closure of inadvertent durotomies that occur during minimally invasive spinal surgery can be technically difficult to accomplish when using standard knot-tying and suture management techniques, owing to the narrow and deep surgical corridor afforded by tubular retraction systems. The U-Clip is a novel device that can achieve tight tissue approximation without the need for knot-tying and excessive suture manipulation, making it ideally suited for use in minimally invasive spinal surgeries. We performed a retrospective review of patients who underwent minimally invasive decompressive procedures complicated by durotomy and repaired using U-Clips for the period January 2008 to January 2010. A total of seven patients were identified. Four of the seven patients were male. Six patients underwent lumbar laminectomy or discectomy. One patient underwent resection of a cervical synovial cyst. In each patient, the durotomy was repaired primarily using U-Clips. All six lumbar patients were discharged home on the same day, and the remaining patient was discharged the following morning. Mean follow-up was 6.3 months. No patient experienced symptoms related to persistent cerebrospinal fluid leakage. Primary closure of an inadvertent durotomy occurring during minimally invasive spinal surgery can be effectively achieved using the self-closing U-Clip device.

  7. Groups as Epistemic Providers: Need for Closure and the Unfolding of Group-Centrism

    Science.gov (United States)

    Kruglanski, Arie W.; Pierro, Antonio; Mannetti, Lucia; De Grada, Eraldo

    2006-01-01

    Theory and research are presented relating the need for cognitive closure to major facets of group behavior. It is suggested that a high need for closure, whether it is based on members' disposition or the situation, contributes to the emergence of a behavioral syndrome describable as group-centrism--a pattern that includes pressures to opinion…

  8. Intrahepatic congenital portosystemic shunts in dogs: short- and long-term outcome of suture attenuation.

    Science.gov (United States)

    Tivers, M S; Lipscomb, V J; Bristow, P; Brockman, D J

    2017-11-22

    To report the short- and long-term outcomes of one- or two-staged suture attenuation for complete closure of intrahepatic congenital portosystemic shunts in dogs. Retrospective cohort study of dogs surgically treated for intrahepatic congenital portosystemic shunts between February 2000 and March 2015. Long-term follow-up was conducted by telephone conversations with the referring veterinary surgeon, owner, or both. In total, 55 dogs had suture attenuation of their intrahepatic congenital portosystemic shunt; 10 dogs (18·2%) tolerated complete attenuation, whilst 45 dogs (81·8%) tolerated partial attenuation. Postoperative complications occurred in 24 dogs (43·6%), and six dogs (10·9%) died. Repeat surgery was performed in 33 of 39 dogs (84·6%) that had previously undergone partial attenuation, and 27 of these (84·9%) ultimately achieved complete shunt attenuation. One dog (3·0%) died following second surgery, resulting in an overall postoperative mortality of seven of 55 (12·7%). Detailed follow-up was available for 22 dogs that were still alive at a median of 29 months after surgery (7·4 to 103·1) with a subjectively good quality of life. Of 17 dogs (82·4%), 14 with complete attenuation in one or two surgeries had an excellent outcome compared with one of five dogs (20%) with persistent shunting. Staged suture ligation resulted in a high proportion of complete attenuation and reduced persistent shunting compared with a single surgery. Repeat surgery was associated with fewer complications than the first surgery. The proportion of dogs with an excellent outcome was greater for those that had complete attenuation in one or two surgeries compared with those with persistent shunting. © 2017 British Small Animal Veterinary Association.

  9. Closure report for N Reactor

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    This report has been prepared to satisfy Section 3156(b) of Public Law 101-189 (Reports in Connection with Permanent Closures of Department of Energy Defense Nuclear Facilities), which requires submittal of a Closure Report to Congress by the Secretary of Energy upon the permanent cessation of production operations at a US Department of Energy (DOE) defense nuclear facility (Watkins 1991). This closure report provides: (1) A complete survey of the environmental problems at the facility; (2) Budget quality data indicating the cost of environmental restoration and other remediation and cleanup efforts at the facility; (3) A proposed cleanup schedule.

  10. Arthroscopic suture anchor capsulorrhaphy versus labral-based suture capsulorrhaphy in a cadaveric model.

    Science.gov (United States)

    Gillis, Robert C; Donaldson, Christopher T; Kim, Hyunchul; Love, James M; Dreese, James C

    2012-11-01

    The purpose of this study was to establish whether suture anchor capsulorrhaphy (SAC) is biomechanically superior to suture capsulorrhaphy (SC) in the management of recurrent anterior shoulder instability without a labral avulsion. Twelve matched pairs of shoulders were randomized to either SC or SAC. Specimens were mounted in 60° of abduction and 90° of external rotation. Testing was conducted on an MTS servohydraulic load testing device (MTS, Eden Prairie, MN). A compressive load of 22 N was applied, followed by a 2-N anterior and posterior force to establish a 0 point. Translation with 10-N anterior and posterior loads was recorded for baseline laxity measurement. Arthroscopic capsulorrhaphy was performed with either 3 solitary sutures or 3 suture anchors. Specimens were remounted and returned to the 0 point. Translation was measured with 10-N anterior and posterior loads to determine reduction in translation. Specimens were then loaded to failure to the 0 point at a rate of 0.1 mm/s. Load to failure was significantly greater (P = .02) in the SC group (13.6 ± 1.0 N) versus the SAC group (20.5 ± 2.8 N). No differences were found between SC (2.7 ± 0.7 mm) and SAC (2.3 ± 0.6 mm) when we compared reduction of anterior translation with a 10-N load. The percent reduction of anterior displacement with a 10-N load was similar for the SC (49.9%) and SAC (49.6%) groups. The dominant mode of failure in the study was suture pull-through of the capsular tissue. Our study indicates that labral-based SC and SAC similarly reduce anterior glenohumeral translation at low loading conditions. Load-to-failure studies indicate that SAC exhibits significantly greater resistance to translation at higher loading conditions. Our study suggests that the use of a suture anchor when one is performing a capsulorrhaphy may provide biomechanical advantage at high loading conditions. Our study suggests that when one is performing capsulorrhaphy, the use of a suture anchor may provide

  11. Suture locking of isolated internal locking knotless suture anchors is not affected by bone quality

    Science.gov (United States)

    Woodmass, Jarret M; Matthewson, Graeme; Ono, Yohei; Bois, Aaron J; Boorman, Richard S; Lo, Ian KY; Thornton, Gail M

    2015-01-01

    Purpose The purpose of this study was to evaluate the mechanical performance of different suture locking mechanisms including: i) interference fit between the anchor and the bone (eg, 4.5 mm PushLock, 5.5 mm SwiveLock), ii) internal locking mechanism within the anchor itself (eg, 5.5 mm SpeedScrew), or iii) a combination of interference fit and internal locking (eg, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S). Methods Anchors were tested in foam blocks representing normal (20/8 foam) or osteopenic (8/8 foam) bone, using standard suture loops pulled in-line with the anchor to isolate suture locking. Mechanical testing included cyclic testing for 500 cycles from 10 N to 60 N at 60 mm/min, followed by failure testing at 60 mm/min. Displacement after 500 cycles at 60 N, number of cycles at 3 mm displacement, load at 3 mm displacement, and maximum load were evaluated. Results Comparing 8/8 foam to 20/8 foam, load at 3 mm displacement and maximum load were significantly decreased (Panchors that, even in part, relied on an interference fit suture locking mechanism (ie, 4.5 mm PushLock, 5.5 mm SwiveLock, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S). Bone quality did not affect the mechanical performance of 5.5 mm SpeedScrew anchors which have an isolated internal locking mechanism. Conclusion The mechanical performance of anchors that relied, even in part, on interference fit were affected by bone quality. Isolated internal locking knotless suture anchors functioned independently of bone quality. Anchors with a combined type (interference fit and internal locking) suture locking mechanism demonstrated similar mechanical performance to isolated internal locking anchors in osteopenic foam comparing similar sized anchors. Clinical relevance In osteopenic bone, knotless suture anchors that have an internal locking mechanism (isolated or combined type) may be advantageous for secure tendon fixation to bone. PMID:26124683

  12. Neural tube closure in the chick embryo is multiphasic.

    Science.gov (United States)

    Van Straaten, H W; Janssen, H C; Peeters, M C; Copp, A J; Hekking, J W

    1996-11-01

    Progression of neurulation in the chick embryo has not been well documented. To provide a detailed description, chick embryos were stained in ovo after the least manipulation possible to avoid distortion of the neural plate and folds. This allowed a morphological and morphometric description of the process of neurulation in relatively undisturbed chick embryos. Neurulation comprises several specific phases with distinct closure patterns and closure rates. The first closure event occurs, de novo, in the future mesencephalon at the 4-6 somite stage (sst 4-6). Soon afterwards, at sst 6-7, de novo closure is seen at the rhombocervical level in the form of multisite contacts of the neural folds. These contacts occur in register with the somites, suggesting that the somites may play a role in forcing elevation and apposition of the neural folds. The mesencephalic] and rhombocervical closure events define an intervening rhombencephalic neuropore, which is present for a brief period before it closes. The remaining pear-shaped posterior neuropore (PNP) narrows and displaces caudally, but its length remains constant in embryos with seven to ten somites, indicating that the caudal extension of the rhombocervical closure point and elongation of the caudal neural plate are keeping pace with each other. From sst 10 onward, the tapered cranial portion of the PNP closes fast in a zipper-like manner, and, subsequently, the wide caudal portion of the PNP closes rapidly as a result of the parallel alignment of its folds, with numerous button-like temporary contact points. A role for convergent extension in this closure event is suggested. The final remnant of the PNP closes at sst 18. Thus, as in mammals, chick neurulation involves multisite closure and probably results form several different development mechanisms at varying levels of the body axis.

  13. A comparison of running suture versus figure-8 sutures as the initial step in achieving hemostasis during laparoscopic partial nephrectomy.

    Science.gov (United States)

    Rosenblatt, Gregory S; Fuchs, Gerhard J

    2010-03-01

    During laparoscopic partial nephrectomy, the importance of the initial suture placed under warm ischemic conditions cannot be underestimated. Inadequate hemostasis may lead to further surgical complications. Our goal was to determine which method of suture ligation (running vs figure-8 interrupted) provides better initial hemostasis when performing partial nephrectomy in an ex-vivo porcine model. Deep partial nephrectomy defects were cut in the lateral aspect of six porcine kidneys. The renal artery was cannulated, and the kidneys were perfused from a water reservoir. The level (cm H(2)O) at which parenchymal leakage occurred was measured and recorded in three situations: No parenchymal suture; running suture along the base of the defect; and interrupted figure-8 sutures placed in parallel along the base of the defect. Six kidneys were studied. Using interrupted figure-8 sutures, the mean leak pressure was 56.7 cm H(2)O (over baseline). Using a running suture, the mean leak pressure was 147.5 cm H(2)O (over baseline). Mean values were compared using two-tailed t test and found to be statistically significant (P = 0.05). In an ex-vivo porcine kidney model, use of a running suture along the base of a renal tumor defect (simulating that which is seen during partial nephrectomy) appears to allow for better initial hemostatic control, as compared with interrupted figure-8 sutures placed in parallel.

  14. Biomechanical analysis of suture anchors and suture materials in the canine femur.

    Science.gov (United States)

    Giles, James T; Coker, Demir; Rochat, Mark C; Payton, Mark E; Subramarian, Vijay; Bartels, Kenneth E

    2008-01-01

    Biomechanical analysis of acute load to failure (ALF) of 3 veterinary and 1 human suture anchor and cyclic load to failure with two suture material/suture anchor constructs in canine femoral condyles. Biomechanical in vitro study. Cadaveric femora from 20-30 kg dogs. Three veterinary and 1 human suture anchor were placed in the cranial and caudal aspects of the femoral condyle and subjected to 0 degrees ALF. Anchors were loaded with 5 USP Fiberwire or 27 kg test nylon leader line (NLL) and subjected to 90 degrees cyclic testing for 10,000 cycles followed by ALF at 90 degrees. No significant difference in ALF for any anchor type was detected in the cranial aspect of the femoral condyle; however all veterinary anchors had higher ALF in the caudal aspect of the femoral condyle. In cyclic testing, the constructs in descending order (most cycles to least) were: (1) FlexiTwist/NLL, (2) Securos/Fiberwire, Securos/NLL, (3) IMEX/Fiberwire, IMEX/NLL, and (4) FlexiTwist/Fiberwire, Fastin/Fiberwire. Fiberwire was significantly stronger than NLL in post-cycling ALF testing. Veterinary anchors had higher ALF in the caudal versus cranial aspect of the femoral condyle. Except for the FlexiTwist in which NLL performed better, Fiberwire and NLL both had similar cyclic performance with each veterinary anchor type. The veterinary anchors exceeded the human anchor in ALF and cycles to failure. The tested veterinary suture anchors with Fiberwire or NLL may be used in the femoral condyle, preferably in the caudal aspect, and should withstand estimated loading conditions in appropriately confined postoperative canine patients.

  15. Surgical device for supporting corneal suturing

    Science.gov (United States)

    Ventura, Liliane; Oliveira, Gunter C. D.; De Groote, Jean-Jacques; Sousa, Sidney J. F.; Saia, Paula

    2009-02-01

    A system for ophthalmic surgery support has been developed in order to minimize the residual astigmatism due to the induced irregular shape of the cornea by corneal suture. The system projects 36 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry and the circularity of the suture. Measurements in the range of 32D - 55D (up to 23D of astigmatism are possible to be obtained) and a self-calibration system has been designed in order to keep the system calibrated. Steel precision spheres have been submitted to the system and the results show 99% of correlation with the fabricant's nominal values. The system has been tested in 13 persons in order to evaluate its clinical applicability and has been compared to a commercial keratometer Topcon OM-4. The correlation factors are 0,92 for the astigmatism and 0.99 for the associated axis. The system indicates that the surgeon should achieve circularity >=98% in order to do not induce astigmatisms over 3D.

  16. An easy and safe way of left ventriculotomy closure in patients with left ventricle thrombi during the subacute phase of anterior myocardial infarction.

    Science.gov (United States)

    Celik, Sekip K; Sen, Mucettin; Buket, Suat; Yuksel, Munevver

    2003-01-01

    Left ventricle thrombi occurring following myocardial infarction are usually left to spontaneous resolution to avoid a left ventriculotomy in the early phase of myocardial healing. We describe a simple and safe method of ventricular closure in patients with left ventricular thrombi embolizing to the lower extremities following acute anterior myocardial infarction. Ventricles were closed by epicardially running 5/0 polypropylene sutures in continuous fashion to avoid the myocardial tearing of heavier suture materials and the late adverse effects of Teflon use. In follow-up of the patients, no early and late complications were found with this method.

  17. One hundred percent fascial approximation can be achieved in the postinjury open abdomen with a sequential closure protocol.

    Science.gov (United States)

    Burlew, Clay Cothren; Moore, Ernest E; Biffl, Walter L; Bensard, Denis D; Johnson, Jeffrey L; Barnett, Carlton C

    2012-01-01

    Multiple techniques have been introduced to obtain fascial closure for the open abdomen. Vacuum-assisted closure has reduced but not eliminated the use of either split-thickness skin grafts to cover the exposed bowel or mesh (prosthetic or biological) approximation of the fascia. We hypothesized that a sequential closure technique performed by a systematic protocol would achieve a higher rate of primary fascial closure than other described techniques. Our technique of sequential fascial closure was initiated in 2005. Patients with a postinjury open abdomen undergoing the technique were compared with those patients who did not follow the protocol. In brief, vacuum-assisted closure white sponges cover the bowel; the fascia is placed under moderate tension over the white sponges with no. 1-polydioxanone sutures; the black sponge is placed on top of this with the standard occlusive dressing; patients undergo partial fascial closure and replacement of the sponge sandwich every 2 days until completely closed. Protocol violations were defined as not returning to the operating room every other day and absence of fascial retention sutures. Patients who died before return to the operating room in the first 48 hours were excluded. One hundred consecutive patients underwent damage control surgery during the five-year study period and survived to second laparotomy; 49 patients attained fascial closure at the second laparotomy. Fifty-one patients required an open abdomen after the second laparotomy and comprise the study population. The majority were men (80%) with a mean age of 34.7 years ± 2.0 years, mean injury severity score of 37.1 ± 2.4, and mean abdominal trauma index of 26.4 ± 2.1. Average initial base deficit was 15.7 ± 0.6 and 24-hour red cell transfusions were 20.4 ± 2.4 units. Of the 51 patients, 29 followed the protocol and 100% had fascial closure. Of the 22 patients who did not follow the protocol, 12 (55%) attained fascial closure. There were no significant

  18. Biomechanical comparison of tibial eminence fracture fixation with high-strength suture, EndoButton, and suture anchor.

    Science.gov (United States)

    Hapa, Onur; Barber, F Alan; Süner, Ganim; Özden, Raif; Davul, Serkan; Bozdağ, Ergun; Sünbüloğlu, Emin

    2012-05-01

    To biomechanically compare anterior cruciate ligament (ACL) tibial bony avulsion fixation by suture anchors, EndoButtons (Smith & Nephew, Andover, MA), and high-strength sutures subjected to cyclic loading. Type III tibial eminence fractures were created in 49 ovine knees, and 7 different types of repairs were performed. Each repair group contained 7 specimens. The repair groups were as follows: No. 2 FiberWire (Arthrex, Naples, FL); No. 2 UltraBraid (Smith & Nephew); No. 2 MaxBraid (Arthrotek, Warsaw, IN); No. 2 Hi-Fi (ConMed Linvatec, Largo, FL); No. 2 OrthoCord (DePuy Mitek, Raynham, MA); Ti-Screw suture anchor (Arthrotek); and titanium EndoButton. These constructs were cyclically loaded (500 cycles, 0 to 100 N, 1 Hz) in the direction of the native ACL and loaded to failure (100 mm/min). Endpoints included ultimate failure load (in Newtons); pullout stiffness (in Newtons per millimeter); cyclic displacement (in millimeters) after 100 cycles, between 100 and 500 cycles, and after 500 cycles; and mode of failure. Bone density testing was performed in all knees. Bone density was not different among the groups. The EndoButton group had a higher ultimate failure load than the FiberWire, UltraBraid, Hi-Fi, and suture anchor groups (P suture anchor group (P suture anchor group had less displacement than the Hi-Fi and FiberWire groups (P suture rupture. Under cyclic loading conditions in an ovine model, EndoButton fixation of tibial eminence fractures provided greater initial fixation strength than suture anchor fixation or fixation with various high-strength sutures except for OrthoCord. During initial cyclic loading of ACL tibial eminence fractures, the strength of the repair construct should be taken into consideration because conventional suture repair even with ultrahigh-molecular-weight polyethylene sutures may not provide enough strength. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Osterix/Sp7 limits cranial bone initiation sites and is required for formation of sutures.

    Science.gov (United States)

    Kague, Erika; Roy, Paula; Asselin, Garrett; Hu, Gui; Simonet, Jacqueline; Stanley, Alexandra; Albertson, Craig; Fisher, Shannon

    2016-05-15

    During growth, individual skull bones overlap at sutures, where osteoblast differentiation and bone deposition occur. Mutations causing skull malformations have revealed some required genes, but many aspects of suture regulation remain poorly understood. We describe a zebrafish mutation in osterix/sp7, which causes a generalized delay in osteoblast maturation. While most of the skeleton is patterned normally, mutants have specific defects in the anterior skull and upper jaw, and the top of the skull comprises a random mosaic of bones derived from individual initiation sites. Osteoblasts at the edges of the bones are highly proliferative and fail to differentiate, consistent with global changes in gene expression. We propose that signals from the bone itself are required for orderly recruitment of precursor cells and growth along the edges. The delay in bone maturation caused by loss of Sp7 leads to unregulated bone formation, revealing a new mechanism for patterning the skull and sutures. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Effect of nylon suture diameter on induced astigmatism after phacoemulsification.

    Science.gov (United States)

    Mendívil, A

    1997-10-01

    To prospectively compare the clinical results of 10-0 and 9-0 monofilament nylon sutures after phacoemulsification with poly(methyl methacrylate) intraocular lens implantation through a 4.0 mm cruciate incision. Department of Ophthalmology, Ramón y Cajal Hospital, Madrid, Spain. One hundred eyes with cataract were randomly assigned to have surgery using a 10-0 or a 9-0 nylon suture. Except for suture diameter, identical surgical methods were used in every case. Data on uncorrected visual acuity, keratometry and postoperative astigmatism were analyzed up to 12 months after surgery. Both groups had similar uncorrected visual acuity. Mean postoperative corneal astigmatism was against the rule in the 10-0 nylon suture group and with the rule in the 9-0 nylon suture group. Significant differences were found between groups (P suture diameters offered satisfactory clinical results. Patients with preoperative with-the-rule astigmatism might benefit from 10-0 nylon sutures and those with preoperative against-the-rule astigmatism, from 9-0 nylon sutures.

  1. Bridge Suture for Successful McDonald Emergency Cerclage.

    Science.gov (United States)

    Tanaka, Masaaki; Hori, Yoshiaki; Shirafuji, Aya; Kato, Mitsunori; Kato, Jyun; Kobayashi, Hiroto; Tsuchida, Toru; Fukae, Tsukasa

    2017-01-01

    To create awareness about a surgical technique termed bridge suture, which is performed as a pretreatment before a McDonald cerclage is performed on an emergency to treat severe cervical insufficiency. Procedures for bridge suture were reviewed in detail and outcomes of 16 patients treated with bridge suture followed by McDonald cerclage were evaluated retrospectively. Using the bridge suture, the edges of uterine cervix were temporarily sutured and the external uterine os was closed, while the hourglass-shaped fetal membranes were concomitantly confined within the cervix; subsequently, a McDonald cerclage was performed. Over a 22-year period, 16 patients with a dilated cervix and bulging fetal membranes were treated using the technique of bridge suture followed by an emergency cerclage. The mean gestational age at cerclage was 22.5 weeks; the mean gestational age at delivery was 30.7 weeks; and the mean interval between cerclage and delivery was 8.2 weeks. In 15 out of 16 cases, cerclage was performed without encountering any complications. No maternal complications, including cervical laceration, were observed. The mean body weight of 17 neonates, including that of a twin, was 1,516 g and of them, 15 neonates survived. The important outcome of bridge suture is the replacement of fetal membranes back into the uterine cavity before McDonald's cerclage is performed. Pretreatment with bridge suture may facilitate the performance of a successful emergency cerclage and contribute to good maternal and neonatal outcomes. © 2016 S. Karger AG, Basel.

  2. Autoadjustable sutures and modified seldinger technique applied to laparoscopic jejunostomy.

    Science.gov (United States)

    Pili, Diego; Ciotola, Franco; Riganti, Juan Martín; Badaloni, Adolfo; Nieponice, Alejandro

    2015-02-01

    This is a simple technique to be applied to those patients requiring an alternative feeding method. This technique has been successfully applied to 25 patients suffering from esophageal carcinoma. The procedure involves laparoscopic approach, suture of the selected intestinal loop to the abdominal wall and jejunostomy using Seldinger technique and autoadjustable sutures. No morbidity or mortality was reported.

  3. Suture granuloma after orchiectomy: sonography, doppler and elastography features

    Directory of Open Access Journals (Sweden)

    Mustafa Secil

    2015-08-01

    Full Text Available ABSTRACTSuture granuloma is a mass forming benign lesion that develops at the site of surgery as a foreign body reaction to non-absorbable suture material. We present a case of suture granuloma that developed at the inguinal region after orchiectomy, and define the sonography, color Doppler sonography and real-time ultrasound elastography findings in correlation with the histopathological findings.

  4. Nose tip refinement using interdomal suture in caucasian nose

    Directory of Open Access Journals (Sweden)

    Pasinato, Rogério

    2012-01-01

    Full Text Available Introduction: Refinement of the nose tip can be accomplished by a variety of techniques, but currently, the use of sutures in the nasal tip with conservative resection of the alar cartilage is the most frequently recommended approach. Objective: To classify the nasal tip and to demonstrate the interdomal suture applied to nasal tip refinement in the Caucasian nose, as well as to provide a simple and practical presentation of the surgical steps. Method: Development of surgical algorithm for nasal tip surgery: 1. Interdomal suture (double binding suture, 2. Interdomal suture with alar cartilage weakening (cross-hatching, 3. Interdomal suture with cephalic removal of the alar cartilage (McIndoe technique based on the nasal tip type classification. This classification assesses the interdomal distance (angle of domal divergence and intercrural distance, domal arch width, cartilage consistency, and skin type. Interdomal suture is performed through endonasal rhinoplasty by basic technique without delivery (Converse-Diamond technique under local anesthesia Conclusion: This classification is simple and facilitates the approach of surgical treatment of the nasal tip through interdomal suture, systematizing and standardizing surgical maneuvers for better refinement of the Caucasian nose.

  5. Punctal occlusion with Prolene suture material in the patients with ...

    African Journals Online (AJOL)

    Aim: To analyze the efficacy and outcomes of punctal occlusion with 5-0 Prolene suture material for the treatment of dry eye. Materials and. Methods: A total of 20 patients with moderate and severe dry eyes, recalcitrant to maximal medical therapy, underwent temporary punctal occlusion with 5-0 Prolene suture material.

  6. Suture associated corneal abscess three years after cataract surgery ...

    African Journals Online (AJOL)

    We describe a case of corneal abscess presenting three years after uneventful cataract extraction with posterior chamber lens implantation through a limbal incision secured with threesutures placed in the clear cornea. After removing the abscess, a loose10/0 nylon suture was found at the base of an ulcer. The suture was ...

  7. Signaling mechanisms implicated in cranial sutures pathophysiology: Craniosynostosis

    Directory of Open Access Journals (Sweden)

    Maria A. Katsianou

    2016-12-01

    Full Text Available Normal extension and skull expansion is a synchronized process that prevails along the osteogenic intersections of the cranial sutures. Cranial sutures operate as bone growth sites allowing swift bone generation at the edges of the bone fronts while they remain patent. Premature fusion of one or more cranial sutures can trigger craniosynostosis, a birth defect characterized by dramatic manifestations in appearance and functional impairment. Up until today, surgical correction is the only restorative measure for craniosynostosis associated with considerable mortality. Clinical studies have identified several genes implicated in the pathogenesis of craniosynostosis syndromes with useful insights into the underlying molecular signaling events that determine suture fate. In this review, we exploit the intracellular signal transduction pathways implicated in suture pathobiology, in an attempt to identify key signaling molecules for therapeutic targeting.

  8. A new uterine compression suture for postpartum haemorrhage with atony.

    Science.gov (United States)

    Zheng, J; Xiong, X; Ma, Q; Zhang, X; Li, M

    2011-02-01

    Postpartum haemorrhage (PPH) is a major cause of worldwide maternal mortality and is still associated with significant morbidity. After the B-Lynch suture was reported in 1997, several different uterine compression sutures were found to be successful in controlling PPH. In this paper, we describe another simple variation of the uterine compression suture technique, which was performed without an incision in the uterine wall, without entering the uterine cavity and without suturing the anterior and posterior walls of the uterus together, so minimising the trauma to the uterus. This new uterine compression suture is an effective and safe surgical treatment for PPH caused by atony. It has the potential to apply to intractable PPH after vaginal delivery.

  9. RCRA closure of mixed waste impoundments

    Energy Technology Data Exchange (ETDEWEB)

    Blaha, F.J. [Doty and Associates (United States); Greengard, T.C.; Arndt, M.B. [Rockwell International (United States)

    1989-11-01

    A case study of a RCRA closure action at the Rocky Flats Plant is presented. Closure of the solar evaporation ponds involves removal and immobilization of a mixed hazardous/radioactive sludge, treatment of impounded water, groundwater monitoring, plume delineation, and collection and treatment of contaminated groundwater. The site closure is described within the context of regulatory negotiations, project schedules, risk assessment, clean versus dirty closure, cleanup levels, and approval of closure plans and reports. Lessons learned at Rocky Flats are summarized.

  10. Microbial keratitis after penetrating keratoplasty: impact of sutures.

    Science.gov (United States)

    Moorthy, Sonia; Graue, Enrique; Jhanji, Vishal; Constantinou, Marios; Vajpayee, Rasik B

    2011-08-01

    To determine the impact of presence or absence of sutures in cases with post-penetrating keratoplasty (PKP) microbial keratitis. A 10-year retrospective chart review of post-PKP patients admitted with microbial keratitis at the Royal Victorian Eye and Ear Hospital, Melbourne, between January 1998 and December 2008 was undertaken. Patients were categorized in 2 groups, "sutures present" and "sutures absent." Main parameters evaluated were clinical and microbiological profile and treatment outcome. One hundred and twenty-two episodes of microbial keratitis were noted in 101 patients: 71 (58.2%) with sutures present and 51 (41.8%) with sutures absent. Overall, pseudophakic bullous keratopathy was the most common indication for keratoplasty (P=.92). Ocular surface disorder was the commonest risk factor associated with the occurrence of infection in both groups (P=.17). Infections caused by Moraxella sp. (P=.001) were significantly more common in the "sutures absent" group. Surgical interventions were required for 47 episodes (39%), with corneal gluing performed in significantly higher number of cases in the "sutures absent" group (40% vs 15%; P=.05). Multivariate analyses did not reveal any significant associations. Final mean visual acuity outcome was poorer in the "sutures absent" group (logMAR 2.10 ± 0.92 vs 1.76 ± 0.96; P=.04). Corneal graft infections, in the presence and absence of sutures, share similar indications and risk factors. However, infections caused by indolent microorganisms were more prevalent in grafts without sutures. This group of patients required a higher number of surgical interventions in the form of corneal gluing and the overall visual outcome was poor. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Bacterial Contamination of Surgical Suture Resembles a Biofilm

    Science.gov (United States)

    Henry-Stanley, Michelle J.; Hess, Donavon J.; Barnes, Aaron M.T.; Dunny, Gary M.

    2010-01-01

    Abstract Background Although much attention is currently directed to studying microbial biofilms on a variety of surfaces, few studies are designed to study bacterial growth on surgical suture. The purpose of this study was to compare the kinetic development of Staphylococcus aureus and Enterococcus faecalis on five surgical suture materials and to clarify factors that might influence this growth. Methods Pure cultures of S. aureus and E. faecalis were incubated with five types of suture for four days using either tissue culture medium or a bacterial growth medium. Suture-associated bacteria were quantified daily. In selected experiments, the bacterial growth medium was supplemented with heparin, a substance known to promote S. aureus biofilm formation. The ultrastructure of S. aureus biofilm developing on braided suture was studied with scanning electron microscopy. Results Staphylococcus aureus and E. faecalis were recovered in greater numbers (typically p suture, and the numbers of bacteria were greater (often p sutures incubated in bacterial growth medium rather than tissue culture medium. Addition of heparin 1,000 U/mL to silk or braided polyglactin 910 suture incubated three days with S. aureus resulted in greater numbers of bacteria on day one but not on subsequent days. Scanning electron microscopy showed a maturing S. aureus biofilm that developed from small clusters of cells among amorphous material and fibrillar elements to larger clusters of cells that appeared covered by more consolidated extracellular material. Conclusions Bacterial growth was favored on braided vs. monofilament suture, and heparin enhanced bacterial adherence after day one, but not at subsequent times. Staphylococcus aureus adhered to suture material and formed a structure consistent with a bacterial biofilm. PMID:20673144

  12. Efficacy of femoral vascular closure devices in patients treated with anticoagulant, abciximab or thrombolytics during percutaneous endovascular procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ha Young; Choo, Sung Wook [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University School of Medicine, Seoul (Korea, Republic of)] (and others)

    2006-03-15

    This study assessed the outcomes of using vascular closure devices following percutaneous transfemoral endovascular procedures in the patients who were treated with heparin, abciximab thrombolytics (urokinase or t-PA) during the procedures. From March 28, 2003 to August 31, 2004, we conducted a prospective and randomized study in which 1,676 cases of 1.180 patients were treated with one of the two different closure devices (the collagen plug device was Angio-Seal{sup TM.}, the suture-mediated closure device was The Closer S{sup TM}) at the femoral access site after instituting percutaneous endovascular procedures. Among the 1,676 cases, 108 cases (the drug group) were treated with heparin only (n=94), thrombolytics only (n=10), heparin and thrombolytics (n=3), or abciximab and thrombolytics (n=1) during the procedures; 1,568 cases (the no-drug group) were treated without any medication. We compared the efficacy and complications between the two groups. Of the drug group, 42 cases underwent arterial closures with the collagen plug devices and 66 cases underwent arterial closures with the suture-mediated closure devices. We also compared the efficacy and complications between these two group. The immediate hemostasis rates were 92.9% (1,456/1,568) in the no drug group and 91.7% (99/108) in the drug group. Early complications occurred in four cases of the drug group. These included two episodes of rebleeding with using the Closer S, which required manual compression for at least 10 minutes, and two episodes of minor oozing with using one Angio-Seal and one Closer S, which required two hours of additional bed rest. There was no late complication. So, the total success rates were 90.8% (1,423/1,568) in the no-drug group and 88.0% (95/108) in the drug group. These results were not significantly different between the two groups ({rho}=0.34). In the drug group, the difference of the successful hemostasis rate between the collagen plug devices and the suture

  13. Mitomycin C "straight scleral tunnel incision"--trabeculectomy with a releasable suture.

    Science.gov (United States)

    Wang, Lin-nong; Fang, Fang; Zhang, Yang; Chen, Li-xun; Zhao, Tai-hong; Xiao, Lei; Tang, Hong

    2006-09-01

    To evaluate the efficacy of "straight scleral tunnel incision" -trabeculectomy with a releasable suture supplemented with mitomycin C (MMC) on reducing intraocular pressure (IOP), complications, and corneal astigmatism in patients with primary angle-closure glaucoma (PACG). Totally 217 acute or chronic PACG patients with occludable angle above 180 degrees and IOP above 21 mm Hg were divided into 3 groups. Patients in group A (98 cases, 128 eyes), B (71 cases, 95 eyes), and C (48 cases, 60 eyes) were treated with "straight scleral tunnel incision"-trabeculectomy with a releasable suture supplemented with MMC, releasable suture trabeculectomy with MMC, and trabeculectomy with MMC, respectively. IOP, complications, and surgically induced astigmatism (SIA) were evaluated preoperatively and up to 12 months postoperatively. IOP of 2 weeks after treatment was significantly lower than preoperative IOP in all the 3 groups (all P astigmatism among the 3 groups. The corneal astigmatism after 2 weeks in group A (1.71 +/- 1.47D) was higher than that before operation (1.28 +/- 1.05D, P = 0.126). With 12 months gone, the astigmatism almost returned to preoperative levels. The corneal astigmatisms after 2 weeks in group B and C (1.99 +/- 1.20D and 2. 22 +/- 1.39D) were significantly higher than those before operation (1.20 +/- 0.85D and 1.18 +/- 0.93D, P = 0.002, P = 0.001), respectively. With 12 months gone, the mean astigmatisms in group B and C (1.87 +/- 0.91D and 1.90 +/- 1.16D) were still significantly higher than those before operation (P = 0.001, P = 0.003). The highest astigmatic polar values in group A, B, and C (1.00D, 1. 89D, and 1. 77D) occurred after 2 weeks, 1 month, and 1 month postoperation, respectively, which were significantly higher than those before operation (0.19 +/- 1.32D, 0.12 +/- 1.22D, and 0.17 +/- 1.25D, P incision" -trabeculectomy with a releasable suture supplemented with MMC can reduce complications and get satisfactory results in reducing IOP and

  14. Video self-assessment of basic suturing and knot tying skills by novice trainees.

    Science.gov (United States)

    Hu, Yinin; Tiemann, Debbie; Michael Brunt, L

    2013-01-01

    Self-assessment is important to learning but few studies have utilized video self-assessment of basic surgical skills. We compared a video self-assessment of suturing and knot tying skills by novice trainees to the assessment by a senior attending surgeon. Sixteen senior medical students and 7 beginner surgical interns were video-recorded while performing five suturing and knot tying tasks. All videos were analyzed using an objective structured assessment of technical skills (OSATS) metrics (1-5 scale; 1 = novice, 5 = expert). Video self-assessment was carried out within 4 weeks of an instructional session and subsequently by one senior surgery instructor (blinded to the individual). Both a Global score and total combined OSATS scores were analyzed. Total possible OSATS scores were: interrupted suture-30, subcuticular closure-30, one and two-handed knot tying-25 each, tying in a restricted space 20; maximum combined score-130 points). Confidence levels in performing the tasks pre-test and the value of video self-assessment were rated on a 1-5 Likert scale (1 = low and 5 = high). Data are mean±SD and statistical significance was evaluated using Friedman's test. Self-assessment scoring was significantly higher than the assessment by a senior instructor for three tasks by global score and all five tasks by combined OSATS score (self-assessment 71.8±16.7 vs attending assessment 56.7±11.0, p = 0.007). Mean self-assessment Global scores ranged from 2.5 to 2.8 for all tasks performed compared to 1.8-2.3 for attending surgeon assessment (pvideo self-assessment was rated as a highly valuable (mean 4.3±0.8) component to skills training. Novice trainees over-estimate their basic technical skills performance compared to the assessment by a senior surgeon. Video self-assessment may be a valuable addition to a pre-residency and surgical internship preparatory curriculum in basic suturing and knot tying. Copyright © 2013 Association of Program Directors in Surgery. Published

  15. Holding Strength of Suture: An Experimental Study Using Porcine Kidney

    Science.gov (United States)

    Akpinar, Haluk; Karadag, Mert Ali; Dönmez, Muhammet İrfan; Altunrende, Fatih

    2017-01-01

    Background and Objectives: The search for the perfect suture is going on and has resulted in the introduction of many different suture types into the market. The purpose of this study is to investigate the holding strength (HS) of different sutures in the renal parenchyma in an experimental study on pig kidneys. Methods: The HS that caused sliding of the suture was investigated in 5 adult porcine kidneys with 7 suture variants. HS-caused tearing of the kidney was investigated with 3 suture types on 5 kidneys. The third investigation, performed on 5 porcine kidneys, was a comparison between 2-0 Vicryl sutures with a Hem-o-lok clip and 2-0 V-Loc sutures with 1 knot. The Friedman test was used to compare the groups. Post hoc analysis was performed with the Wilcoxon signed ranks test (Bonferroni corrected). Results: For HS causing sliding of the suture, the mean HSs of the tested sutures were as follows: 2-0 Vicryl with 1 Hem-o-lok clip, 3.26 ± 0.55 N; 2-0 Vicryl with 2 Hem-o-lok clips, 4.1 ± 0.46 N; 2-0 V-Loc, 2.52 ± 0.63 N; 4-0 V-Loc, 1.62 ± 0.17 N; 0 Quill, 0.48 ± 0.16 N; 2-0 Vicryl with 1 Hem-o-lok clip (halfway), 3.62 ± 0.66 N; and 2-0 V-Loc (halfway), 1.02 ± 0.40 N. For HS causing tearing of the kidney, the mean value of 2-way 2-0 Vicryl (Hem-o-lok in the middle) was 13.28 ± 1.38 N, 2-0 2-way Vicryl (Hem-o-lok at the end) was 5.86 ± 0.75 N, and 2-way 2-0 V-Loc was 3.98 ± 1.60 N. For the third group, the difference between the 2 suture variants was not statistically significant. Conclusion: Our study revealed that 2-0 Vicryl (polyglactin 910) sutures with 2 Hem-o-lok clips had the maximum HS in renal parenchyma when compared with other sutures. PMID:28729782

  16. Holding Strength of Suture: An Experimental Study Using Porcine Kidney.

    Science.gov (United States)

    Özkuvanci, Ünsal; Akpinar, Haluk; Karadag, Mert Ali; Dönmez, Muhammet İrfan; Altunrende, Fatih

    2017-01-01

    The search for the perfect suture is going on and has resulted in the introduction of many different suture types into the market. The purpose of this study is to investigate the holding strength (HS) of different sutures in the renal parenchyma in an experimental study on pig kidneys. The HS that caused sliding of the suture was investigated in 5 adult porcine kidneys with 7 suture variants. HS-caused tearing of the kidney was investigated with 3 suture types on 5 kidneys. The third investigation, performed on 5 porcine kidneys, was a comparison between 2-0 Vicryl sutures with a Hem-o-lok clip and 2-0 V-Loc sutures with 1 knot. The Friedman test was used to compare the groups. Post hoc analysis was performed with the Wilcoxon signed ranks test (Bonferroni corrected). For HS causing sliding of the suture, the mean HSs of the tested sutures were as follows: 2-0 Vicryl with 1 Hem-o-lok clip, 3.26 ± 0.55 N; 2-0 Vicryl with 2 Hem-o-lok clips, 4.1 ± 0.46 N; 2-0 V-Loc, 2.52 ± 0.63 N; 4-0 V-Loc, 1.62 ± 0.17 N; 0 Quill, 0.48 ± 0.16 N; 2-0 Vicryl with 1 Hem-o-lok clip (halfway), 3.62 ± 0.66 N; and 2-0 V-Loc (halfway), 1.02 ± 0.40 N. For HS causing tearing of the kidney, the mean value of 2-way 2-0 Vicryl (Hem-o-lok in the middle) was 13.28 ± 1.38 N, 2-0 2-way Vicryl (Hem-o-lok at the end) was 5.86 ± 0.75 N, and 2-way 2-0 V-Loc was 3.98 ± 1.60 N. For the third group, the difference between the 2 suture variants was not statistically significant. Our study revealed that 2-0 Vicryl (polyglactin 910) sutures with 2 Hem-o-lok clips had the maximum HS in renal parenchyma when compared with other sutures.

  17. Objective classification system for sagittal craniosynostosis based on suture segmentation

    Science.gov (United States)

    Qian, Xiaohua; Tan, Hua; Zhang, Jian; Zhuang, Xiahai; Branch, Leslie; Sanger, Chaire; Thompson, Allison; Zhao, Weiling; Li, King Chuen; David, Lisa; Zhou, Xiaobo

    2015-01-01

    Purpose: Spring-assisted surgery is an effective and minimally invasive treatment for sagittal craniosynostosis (CSO). The principal barrier to the advancement of spring-assisted surgery is the patient-specific spring selection. The selection of spring force depends on the suture involved, subtypes of sagittal CSO, and age of the infant, among other factors. Clinically, physicians manually judge the subtype of sagittal CSO patients based on their CT image data, which may cause bias from different clinicians. An objective system would be helpful to stratify the sagittal CSO patients and make spring choice less subjective. Methods: The authors developed a novel informatics system to automatically segment and characterize sutures and classify sagittal CSO. The proposed system is composed of three phases: preprocessing, sutures segmentation, and classification. First, the three-dimensional (3D) skull was extracted from the CT images and aligned with the symmetry of the cranial vault. Second, a “hemispherical projection” algorithm was developed to transform 3D surface of the skull to a polar two-dimensional plane. Through the transformation, an “effective” projected region can be obtained to enable easy segmentation of sutures. Then, the different types of sutures, such as coronal sutures, lambdoid sutures, sagittal suture, and metopic suture, obtained from the segmented sutures were further identified by a dual-projection technique of the midline of the sutures. Finally, 108 quantified features of sutures were extracted and selected by a proposed multiclass feature scoring system. The sagittal CSO patients were classified into four subtypes: anterior, central, posterior, and complex with the support vector machine approach. Fivefold cross validation (CV) was employed to evaluate the capability of selected features in discriminating the four subtypes in 33 sagittal CSO patients. Receiver operating characteristics (ROC) curves were used to assess the robustness

  18. Four-fold benefit of wound closure under high magnification.

    Science.gov (United States)

    Kivelev, Juri; Hernesniemi, Juha

    2013-01-01

    Unaffected wound healing and good cosmetic result after a neurosurgical procedure are important factors measuring a level of care. The usefulness of high magnification of the operating microscope during closure of neurosurgical wounds is evaluated. During a one-year microneurosurgical fellowship, the first author (JK) performed wound closure under the microscope in 200 of 524 neurosurgical operations carried out by the senior author (JH) at the Department of Neurosurgery, Helsinki University Central Hospital. Supratentorial approaches were employed most frequently in 143 patients (72%). Surgeries for infratentorial lesions and the spinal canal comprised 48 (24%) and 9 procedures (4%), respectively. Mean duration of the surgery from skin to skin was 1.8 (range 0.5-6.2) hours. After intradural hemostasis was completed by the senior author, further steps including dural suturing, bone flap fixation, and wound closure were performed by the first author. Wound condition was assessed during the early and late postoperative period. Mean follow-up was 3.2 (range 1-10) months. Early postoperative healing of the wound was uneventful in 180 patients (90%). No wound rupture or postoperative hematoma occurred. In five patients (2.5%), lumbar puncture or spinal drainage was necessary due to significant subcutaneous liquor collection. No wound revision was required. At follow-up, in 196 patients (98%) the postoperative scar was in perfect condition. Neither skin necrosis nor healing problems occurred. Based on our results, we found the high magnification of operating microscope to be beneficial when closing neurosurgical wounds; it allows (1) better hemostasis, (2) precise wound margin approximation, (3) atraumatic handling of the tissues, and (4) improvement of the manual dexterity of the neurosurgeon.

  19. Arthroscopic Fixation of Tibial Eminence Fractures: A Clinical Comparative Study of Nonabsorbable Sutures Versus Absorbable Suture Anchors.

    Science.gov (United States)

    Liao, Weixiong; Li, Zhongli; Zhang, Hao; Li, Ji; Wang, Ketao; Yang, Yimeng

    2016-08-01

    To compare clinical outcomes of arthroscopic therapy for tibial eminence fracture with nonabsorbable suture and absorbable suture anchor. Between February 2010 and September 2012, a total of 60 tibial eminence fracture patients were treated with nonabsorbable suture fixation or absorbable suture anchor fixation under arthroscopy. Patients with tibial plateau fractures and other significant injuries, including osteochondral lesions, meniscal tear, and anterior cruciate ligament (ACL) or mutiligament injuries, were excluded from the study. Radiographs, anterior drawer test (ADT), Lachman test, Lysholm score, and International Knee Documentation Committee (IKDC) 2000 subjective score were employed to evaluate clinical outcomes in follow-up. A total of 41 patients were analyzed. Among these patients, 22 were treated with nonabsorbable suture fixation and 19 with absorbable suture anchor fixation. According to the modified Meyers-McKeever classification, 15 cases were categorized as type II, 21 as type III, and 5 as type IV fractures. The mean time from injury to surgery was 7.1 days (range, 3 to 12 days). All patients were followed up for a median period of 33.7 months (range, 24 to 45 months). Radiographic evaluation showed optimal reduction immediately after operation and bone union within 3 months in all patients. At the final follow-up, there was no limitation of knee motion range in any patient. Grade II laxity was found in 2 cases from suture group and 1 from suture anchor group, showing no significant difference based on ADT (χ(2) = 0.538, P = .764) and Lachman test (χ(2) = 0.550, P = .760). Lysholm and IKDC 2000 subjective scores were significantly improved (P suture fixation and absorbable suture anchor fixation are equivalent techniques in terms of the clinical efficacy of arthroscopic tibial eminence fracture treatment. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc

  20. Preservation of the umbilical cord at the primary fascial closure in infants with gastroschisis.

    Science.gov (United States)

    Nagaya, M; Ando, H; Tsuda, M; Hiraiwa, K; Akatsuka, H

    1993-11-01

    Recently, the survival of patients with gastroschisis has been dramatically improved and it has reached more than 90%. Over the last 10 years, 20 of 21 cases (95%) survived in our hospital. We have been using the primary fascial closure of the abdominal wall as a standard operative procedure. The umbilical cord was usually excised at the operation in order to secure the suture line and prevent wound infection. The survivors sometimes complained of the absence of the umbilicus. However, it was somewhat difficult to create a new umbilicus later by use of the surrounding skin. In the last five cases, we tried to carry out the primary fascial closure with preservation of the umbilical cord. All patients could obtain good cosmetic results with near-normal appearance. Omphalitis or cellulitis was never observed, but a small umbilical hernia occurred in one case.

  1. The Strength of Transosseous Medial Meniscal Root Repair Using a Simple Suture Technique Is Dependent on Suture Material and Position.

    Science.gov (United States)

    Robinson, James R; Frank, Evelyn G; Hunter, Alan J; Jermin, Paul J; Gill, Harinderjit S

    2018-01-01

    A simple suture technique in transosseous meniscal root repair can provide equivalent resistance to cyclic load and is less technically demanding to perform compared with more complex suture configurations, yet maximum yield loads are lower. Various suture materials have been investigated for repair, but it is currently not clear which material is optimal in terms of repair strength. Meniscal root anatomy is also complex; consisting of the ligamentous mid-substance (root ligament), the transition zone between the meniscal body and root ligament; the relationship between suture location and maximum failure load has not been investigated in a simulated surgical repair. (A) Using a knottable, 2-mm-wide, ultra-high-molecular-weight polyethylene (UHMWPE) braided tape for transosseous meniscal root repair with a simple suture technique will give rise to a higher maximum failure load than a repair made using No. 2 UHMWPE standard suture material for simple suture repair. (B) Suture position is an important factor in determining the maximum failure load. Controlled laboratory study. In part A, the posterior root attachment of the medial meniscus was divided in 19 porcine knees. The tibias were potted, and repair of the medial meniscus posterior root was performed. A suture-passing device was used to place 2 simple sutures into the posterior root of the medial meniscus during a repair procedure that closely replicated single-tunnel, transosseous surgical repair commonly used in clinical practice. Ten tibias were randomized to repair with No. 2 suture (Suture group) and 9 tibias to repair with 2-mm-wide knottable braided tape (Tape group). The repair strength was assessed by maximum failure load measured by use of a materials testing machine. Micro-computed tomography (CT) scans were obtained to assess suture positions within the meniscus. The wide range of maximum failure load appeared related to suture position. In part B, 10 additional porcine knees were prepared. Five

  2. Aqua splint suture technique in isolated zygomatic arch fractures.

    Science.gov (United States)

    Kim, Dong-Kyu; Kim, Seung Kyun; Lee, Jun Ho; Park, Chan Hum

    2014-04-01

    Various methods have been used to treat zygomatic arch fractures, but no optimal modality exists for reducing these fractures and supporting the depressed bone fragments without causing esthetic problems and discomfort for life. We developed a novel aqua splint and suture technique for stabilizing isolated zygomatic arch fractures. The objective of this study is to evaluate the effect of novel aqua splint and suture technique in isolated zygomatic arch fractures. Patients with isolated zygomatic arch fractures were treated by a single surgeon in a single center from January 2000 through December 2012. Classic Gillies approach without external fixation was performed from January 2000 to December 2003, while the novel technique has been performed since 2004. 67 consecutive patients were included (Classic method, n = 32 and Novel method, n = 35). An informed consent was obtained from all patients. The novel aqua splint and suture technique was performed by the following fashion: first, we evaluated intraoperatively the bony alignment by ultrasonography and then, reduced the depressed fracture surgically using the Gillies approach. Thereafter, to stabilize the fracture and obtain the smooth facial figure, we made an aqua splint that fit the facial contour and placed monofilament nonabsorbable sutures around the fractured zygomatic arch. The novel aqua splint and suture technique showed significantly correlated with better cosmetic and functional results. In conclusion, the aqua splint suture technique is very simple, quick, safe, and effective for stabilizing repositioned zygomatic arch fractures. The aqua splint suture technique can be a good alternative procedure in isolated zygomatic arch fractures.

  3. Evaluation of an autotutorial-simulator program for instruction of hollow organ closure.

    Science.gov (United States)

    Smeak, D D; Hill, L N; Beck, M L; Shaffer, C A; Birchard, S J

    1994-01-01

    Forty students were randomly assigned into two study groups (traditional, T; and simulator, S) of 20 students each for a core operative practice laboratory. Students were randomly paired and their group assignment and identity remained anonymous to the evaluators throughout the study. Questionnaires were distributed to students to evaluate prior surgical experience and obtain learning resource use information. Before the evaluation sessions, both groups were given identical learning resource opportunities except students in Group S received hollow organ simulators and practice materials for gastrotomy closure. All students were forewarned that surgical instruction would not be available during the evaluation sessions. In the first live animal evaluation session, all student pairs were videotaped after which stomachs were harvested for gross evaluation of the surgical site. Group T performed an additional gastrotomy for video and gross evaluation 2 weeks later. Questionnaire, and gross and video evaluation results were compared statistically between groups and sessions. The hollow organ model did not suitably simulate live stomach tissue; the material was more fragile and stiff and suture cut-out was a problem even with appropriate suture tension and technique. The model was effective for teaching needle placement, instrument usage, creating proper tissue inversion, and methods to minimize instrument handling of tissue during gastrotomy closure. Prior practice with models did not boost student confidence during their live gastrotomy session. The autotutorials (ATs) were well received by students but did not sufficiently address how to manage mucosal eversion, suture tension, and bleeding encountered during live gastrotomy. AT viewing time positively correlated with mean total video score for Group T during both sessions. None of the students had prior experience performing hollow organ closure and no significant difference in experience level was evident between

  4. Experimental investigation on the pressure characteristics of cavity closure region

    Science.gov (United States)

    Wang, Yadong; Yuan, Xulong; Zhang, Yuwen

    2012-12-01

    The most complicated component in cavitating flow and pressure distribution is the flow in the cavity closure line. The cavitating flow and pressure distribution provide critical aspects of flow field details in the region. The integral of pressure results of the hydrodynamic forces, indicate domination in the design of a supercavitating vehicle. An experiment was performed in a water tunnel to investigate the pressure characteristics of the cavity closure region. Ventilation methods were employed to generate artificial cavity, and the ventilation rate was adjusted accordingly to obtain the desired cavity length. An array of pressure transducers was laid down the cavity closure line to capture pressure distribution in this region. The experimental results show that there is a pressure peak in the cavity closure region, and the rise rate of pressure in space tends to be higher in the upwind side when the flow is non-axisymmetric. The transient pressure variations during the cavity formation procedure were also present. The method of measurement in this paper can be referenced by engineers. The result helps to study the flow pattern of cavity closure region, and it can also be used to analyze the formation of supercavitating vehicle hydrodynamics.

  5. Sutural strain in orthopedic headgear therapy: a finite element analysis.

    Science.gov (United States)

    Holberg, Christof; Holberg, Nikola; Rudzki-Janson, Ingrid

    2008-07-01

    The goal of this study was to analyze the strains induced in the sutures of the midface and the cranial base by headgear therapy involving orthopedic forces. Does the mechanical signal induced in the sutures sufficiently account for a growth-influencing effect? A finite element model of the viscerocranium and the neurocranium was used. It consisted of 53,555 tetrahedral elements and 97,550 nodes. The strain induced in the sutures of the cranial base and the midface when applying orthopedic headgear forces of 5 and 10 N was computed and recorded with an interactive measurement tool. The magnitude and the distribution of the measured strains depended on the level and the direction of the acting force. Overall, the strain values measured at the sutures of the midface and the cranial base were moderate. The measured peak values at a load of 5 N per side were usually just below 20 microstrain irrespective of the force direction. A characteristic distribution of strain values appeared on the anatomical structures of the midface and the cranial base for each vector direction. The measurements based on the finite element method provided a good overview of the approximate magnitudes of sutural strains with orthopedic headgear therapy. The signal arriving in the sutures is apparently well below threshold, since the maximum measured strains in most sutures were about 100 fold lower than the minimal effective strain. A skeletal effect of the orthopedic headgear due to a mechanical effect on sutural growth cannot be confirmed from these results. The good clinical efficacy of headgear therapy with orthopedic forces is apparently based mainly on dentoalveolar effects, whereas the skeletal effect due to inhibition of sutural growth is somewhat questionable.

  6. [Endoscopic vacuum-assisted closure].

    Science.gov (United States)

    Wedemeyer, J; Lankisch, T

    2013-03-01

    Anastomotic leakage in the upper and lower intestinal tract is associated with high morbidity and mortality. Within the last 10 years endoscopic treatment options have been accepted as sufficient treatment option of these surgical complications. Endoscopic vacuum assisted closure (E-VAC) is a new innovative endoscopic therapeutic option in this field. E-VAC transfers the positive effects of vacuum assisted closure (VAC) on infected cutaneous wounds to infected cavities that can only be reached endoscopically. A sponge connected to a drainage tube is endoscopically placed in the leakage and a continuous vacuum is applied. Sponge and vacuum allow removal of infected fluids and promote granulation of the leakage. This results in clean wound grounds and finally allows wound closure. Meanwhile the method was also successfully used in the treatment of necrotic pancreatitis.

  7. Vascular closure devices for femoral arterial puncture site haemostasis.

    Science.gov (United States)

    Robertson, Lindsay; Andras, Alina; Colgan, Frances; Jackson, Ralph

    2016-03-07

    Vascular closure devices (VCDs) are widely used to achieve haemostasis after procedures requiring percutaneous common femoral artery (CFA) puncture. There is no consensus regarding the benefits of VCDs, including potential reduction in procedure time, length of hospital stay or time to patient ambulation. No robust evidence exists that VCDs reduce the incidence of puncture site complications compared with haemostasis achieved through extrinsic (manual or mechanical) compression. To determine the efficacy and safety of VCDs versus traditional methods of extrinsic compression in achieving haemostasis after retrograde and antegrade percutaneous arterial puncture of the CFA. The Cochrane Vascular Trials Search Co-ordinator searched the Specialised Register (April 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL) (2015, Issue 3). Clinical trials databases were searched for details of ongoing or unpublished studies. References of articles retrieved by electronic searches were searched for additional citations. We included randomised and quasi-randomised controlled trials in which people undergoing a diagnostic or interventional procedure via percutaneous CFA puncture were randomised to one type of VCD versus extrinsic compression or another type of VCD. Two authors independently extracted data and assessed the methodological quality of trials. We resolved disagreements by discussion with the third author. We performed meta-analyses when heterogeneity (I(2)) was studies (19,192 participants) in the review. We found studies comparing VCDs with extrinsic compression (sheath size ≤ 9 Fr), different VCDs with each other after endovascular (EVAR) and percutaneous EVAR procedures and VCDs with surgical closure after open exposure of the artery (sheath size ≥ 10 Fr). For primary outcomes, we assigned the quality of evidence according to GRADE (Grades of Recommendation, Assessment, Development and Evaluation) criteria as low because of serious imprecision

  8. Perioperative modulating factors on astigmatism in sutured cataract surgery.

    Science.gov (United States)

    Cho, Yang Kyeung; Kim, Man Soo

    2009-12-01

    To evaluate the factors that affect postoperative astigmatism and post-suture removal astigmatism, and to evaluate the risk factors associated with astigmatism axis shift. We performed a retrospective chart review of 130 eyes that had undergone uneventful phacoemulsification cataract surgery. Preoperative astigmatism was divided into four groups (Groups I, II, III, and IV) according to the differences between the axis of preoperative astigmatism (flattest axis) and the incision axis (105 degrees). We analyzed the magnitude and axis of the induced astigmatism after the operation and after suture removal in each group. We also analyzed the factors which affected the postoperative astigmatism and post-suture removal astigmatism in each sub-group of Groups I, II, III, and IV, excluding postoperative or post-suture removal axis shift (specifically, Group I(WAS), II(WAS), III(WAS), and IV(WAS)). We identified the variables associated with the prevalence of postoperative astigmatism axis shift and those associated with the prevalence of post-suture removal axis shift. An increase in the magnitude of postoperative astigmatism was associated with an increase in the preoperative magnitude of astigmatism in Groups I(WAS), II(WAS), and III(WAS) (pastigmatism was associated with an increase in the corneal tunnel length in Groups III(WAS) and IV(WAS) (psuture removal astigmatism was associated with an increase in the magnitude of postoperative astigmatism in Groups I(WAS) and IV(WAS) (psuture removal in Group IV(WAS) (psuture removal astigmatism was associated with late suture removal in Groups I(WAS) and II(WAS). A logistic regression analysis showed that the prevalence of post-suture removal astigmatism axis shift was associated with increased corneal tunnel length, decreased magnitude of postoperative astigmatism, and early suture removal. In order to reduce postoperative and post-suture removal astigmatism, we recommend a short corneal tunnel length and late suture removal

  9. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    haemorrhage >1000 ml, Diabetes, mental disorders. Both suture techniques were 2-layered using a polyglactin 910 multifilament suture (Vicryl Rapid or Vicryl). Treatment A was a continuous suture technique and treatment B was interrupted, inverted stitches. Primary outcomes: Perineal pain and wound healing...... assessed day 1-2 and 10 post partum. Secondary outcomes: patient satisfaction with wound healing, need for secondary repair, superficial pain during intercourse.   Data management: Double entry of all data and intention-to-treat analysis.   Results The follow up rate was 97%. Baseline data were evenly...

  10. Stresses in the midpalatal suture in the maxillary protraction therapy: a 3D finite element analysis

    Directory of Open Access Journals (Sweden)

    Orlando M. Tanaka

    2016-03-01

    Full Text Available Abstract Background The aim of the present work was to evaluate the stress magnitudes and directions along the midpalatal suture in the maxillary protraction therapy. Methods The geometry of the maxilla and teeth were digitally reconstructed based on computer tomography images obtained from the skull of a girl in a mixed dentition stage with skeletal and dental class III malocclusion. An appliance commonly used for rapid palatal expansion (RPE was also digitally modeled for anchorage of the protraction force and meshed for finite element analysis. The maxillary protraction was simulated applying 600 cN (300 cN for each side directed 30° forward and downward to the maxillary occlusal plane. Results The principal stresses, through the force application, exhibited similar distribution patterns. A higher stress area was observed in the region of the midpalatal suture located in front of the incisive canal. All the sections showed vectors of compressive nature. Conclusions Because of the compressive nature of the stresses distributed along the midpalatal suture in the maxillary protraction therapy simulation, which is opposite to the natural growth transversal tendency, maxillary expansion is advisable in clinical cases.

  11. Human Foramen Magnum Area and Posterior Cranial Fossa Volume Growth in Relation to Cranial Base Synchondrosis Closure in the Course of Child Development.

    Science.gov (United States)

    Coll, Guillaume; Lemaire, Jean-Jacques; Di Rocco, Federico; Barthélémy, Isabelle; Garcier, Jean-Marc; De Schlichting, Emmanuel; Sakka, Laurent

    2016-11-01

    To date, no study has compared the evolution of the foramen magnum area (FMA) and the posterior cranial fossa volume (PCFV) with the degree of cranial base synchondrosis ossification. To illustrate these features in healthy children. The FMA, the PCFV, and the ossification of 12 synchondroses according to the Madeline and Elster scale were retrospectively analyzed in 235 healthy children using millimeter slices on a computed tomography scan. The mean FMA of 6.49 cm in girls was significantly inferior to the FMA of 7.67 cm in boys (P < .001). In both sexes, the growth evolved in a 2-phase process, with a phase of rapid growth from birth to 3.75 years old (yo) followed by a phase of stabilization. In girls, the first phase was shorter (ending at 2.6 yo) than in boys (ending at 4.33 yo) and proceeded at a higher rate. PCFV was smaller in girls (P < .001) and displayed a biphasic pattern in the whole population, with a phase of rapid growth from birth to 3.58 yo followed by a phase of slow growth until 16 yo. In girls, the first phase was more active and shorter (ending at 2.67 yo) than in boys (ending at 4.5 yo). The posterior interoccipital synchondroses close first, followed by the anterior interoccipital and occipitomastoidal synchondroses, the lambdoid sutures simultaneously, then the petro-occipital and spheno-occipital synchondroses simultaneously. The data provide a chronology of synchondrosis closure. We showed that FMA and PCFV are constitutionally smaller in girls at birth (P ≤ .02) and suggest that a sex-related difference in the FMA is related to earlier closure of anterior interoccipital synchondroses in girls (P = .01). AIOS, anterior interoccipital synchondrosesFMA, foramen magnum areaLS, lambdoid suturesOMS, occipitomastoidal synchondrosesPCFV, posterior cranial fossa volumePIOS, posterior interoccipital synchondrosesPOS, petro-occipital synchondrosesSOS, spheno-occipital synchondrosisyo, years old.

  12. 21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.

    Science.gov (United States)

    2010-04-01

    ... suture. 878.4493 Section 878.4493 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4493 Absorbable poly(glycolide/l-lactide) surgical suture. (a) Identification. An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared and...

  13. Tracking the Archean-Proterozoic suture zone in the northeastern Great Basin, Nevada and Utah

    Science.gov (United States)

    Rodriguez, B.D.; Williams, J.M.

    2008-01-01

    It is important to know whether major mining districts in north-central Nevada are underlain by crust of the Archean Wyoming craton, known to contain major orogenic gold deposits or, alternatively, by accreted crust of the Paleoproterozoic Mojave province. Determining the location and orientation of the Archean-Proterozoic suture zone between these provinces is also important because it may influence subsequent patterns of sedimentation, deformation, magmatism, and hydrothermal activity. The suture zone is exposed in northeastern Utah and south-western Wyoming and exhibits a southwest strike. In the Great Basin, the suture zone strike is poorly constrained because it is largely concealed below a Neoproterozoic-Paleozoic miogeocline and Cenozoic basin fill. Two-dimensional resistivity modeling of three regional north-south magnetotelluric sounding profiles in western Utah, north-central Nevada, and northeastern Nevada, and one east-west profile in northeastern Nevada, reveals a deeply penetrating (>10 km depth), broad (tens of kilometers) conductor (1-20 ohm-meters) that may be the Archean-Proterozoic suture zone, which formed during Early Proterozoic rifting of the continent and subsequent Proterozoic accretion. This major crustal conductor changes strike direction from southwest in Utah to northwest in eastern Nevada, where it broadens to ???100 km width that correlates with early Paleozoic rifting of the continent. Our results suggest that the major gold belts may be over-isolated blocks of Archean crust, so Phanerozoic mineral deposits in this region may be produced, at least in part, from recycled Archean gold. Future mineral exploration to the east may yield large gold tonnages. ?? 2008 Geological Society of America.

  14. Outcome of colostomy closure with different skin closure techniques ...

    African Journals Online (AJOL)

    Background: Colostomy site, which is a potentially contaminated wound, is traditionally closed with interrupted skin stitches and placement of intraperitoneal or parietal or both drains; often with poor cosmetic outcome in our country. This study aims at prospective evaluation of colostomy closure wounds by different ...

  15. Moment Closure for the Stochastic Logistic Model

    National Research Council Canada - National Science Library

    Singh, Abhyudai; Hespanha, Joao P

    2006-01-01

    ..., which we refer to as the moment closure function. In this paper, a systematic procedure for constructing moment closure functions of arbitrary order is presented for the stochastic logistic model...

  16. Automatic Detection of Wild-type Mouse Cranial Sutures

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Darvann, Tron Andre; Hermann, Nuno V.

    In the study of craniofacial malformations, the cranial sutures are often of interest. The premature fusion of sutures occurring in e.g. Crouzon and Apert syndrome can lead to asymmetric head shape, enlarged intracranial pressure and blindness. In large population studies of such syndromes......, automatic detection of the cranial sutures becomes important. We have previously built a craniofacial, wild-type mouse atlas from a set of 10 Micro CT scans using a B-spline-based nonrigid registration method by Rueckert et al. Subsequently, all volumes were registered nonrigidly to the atlas. Using...... these transformations, any annotation on the atlas can automatically be transformed back to all cases. For this study, two rounds of tracing seven of the cranial sutures, were performed on the atlas by one observer. The average of the two rounds was automatically propagated to all the cases. For validation...

  17. Influence of suture regularity on corneal astigmatism after penetrating keratoplasty.

    Science.gov (United States)

    Hjortdal, Jesper; Søndergaard, Anders; Fledelius, Walther; Ehlers, Niels

    2011-08-01

    To investigate whether suture regularity affects corneal astigmatism after keratoplasty. Twenty-one patients undergoing penetrating keratoplasty for various corneal diseases were included in the study. The grafts were sutured in place using a single-running Nylon 10-0 suture, taking 24 bites. Immediately after surgery, standard calibrated images of the grafted eye were captured and stored. Using a dedicated image analysis programme, stitches and needle points were identified, and a number of suture regularity variables were calculated. Corneal topographic images were obtained before suture removal (12 months after surgery) and 3 months after suture removal (18 months after surgery). Topographic measures of astigmatism [surface regularity (SRI), surface asymmetry index (SAI) and simulated keratometric astigmatism] were calculated and correlated with the computed suture regularity variables. The average stitch length was 3.04 ± 0.28 mm and the distance between the outer needle points was 2.53 ± 0.09 mm. The SRI was 1.26 ± 0.36 and the SAI was 1.59 ± 0.67 after 12 months; these decreased to 1.03 ± 0.48 and 0.92 ± 0.46 after 18 months, respectively. Corneal astigmatism was 6.38 ± 2.99 and 5.87 ± 3.13 dioptres after 12 and 18 months, respectively. Suture regularity did not affect SAI, SRI or corneal astigmatism significantly 12 months after surgery. Eighteen months after surgery (3 months after suture removal), the standard deviation on the original stitch length was found to significantly increase corneal astigmatism. In addition, the size of the counter-clockwise angle between stitch and graft radian was correlated significantly with a lower SRI. The origin of corneal astigmatism after penetrating keratoplasty is multifaceted. Regular stitch length and stitch advancement on the surface appears to improve the optical quality of the graft after suture removal. Factors such as stitch depth, suture tension and variations in wound construction might also be

  18. Telephone switchboard closure | 19 December

    CERN Multimedia

    2014-01-01

    Exceptionally, the telephone switchboard will close at 4 p.m. on Friday, 19 December, instead of the usual time of 6 p.m., to allow time for closing all systems properly before the annual closure. Therefore, switchboard operator assistance to transfer calls from/to external lines will stop. All other phone services will run as usual.

  19. An improvised wound closure system

    NARCIS (Netherlands)

    Lapid, Oren

    2006-01-01

    BACKGROUND: Skin stretching harnesses the same viscoelastic properties of the skin as expansion, with the difference that the forces are applied externally and not internally. An improvised system for wound closure is presented. METHOD: The system is assembled using silicone vascular loops used as

  20. Vacuum assisted closure in coloproctology

    NARCIS (Netherlands)

    Bemelman, W.A.

    2009-01-01

    Vacuum-assisted closure has earned its indications in coloproctology. It has been described with variable results in the treatment of large perineal defects after abdominoperineal excision, in the treatment of stoma dehiscence and perirectal abscesses. The most promising indication for

  1. Recurrent vitreous hemorrhage after sutured posterior chamber intraocular lenses.

    Science.gov (United States)

    Fu, Arthur D; McDonald, H Richard; Jumper, J Michael; Aaberg, Thomas M; Smiddy, William E; Robertson, Joseph E; Johnson, Robert N; Ai, Everett

    2004-04-01

    To describe the clinical course and management of patients with late vitreous hemorrhage after scleral suturing of posterior chamber intraocular lenses (PCIOL). The authors reviewed patient demographics, ocular findings, and clinical course of six patients with late (>3 weeks) vitreous hemorrhage after sclera-sutured PCIOL. Intraoperative endoscopy was performed on two patients to better assess the haptic sulcus interaction. Patient age ranged from 39 to 84 years (median 77 years). The interval between scleral suturing of the PCIOL and vitreous hemorrhage ranged from 3 weeks to 68 months (median 5 months). The number of hemorrhages ranged from one to four. The hemorrhage cleared spontaneously in three eyes. Three patients underwent surgery after the hemorrhages including sutured PCIOL removal with concurrent placement of an anterior chamber IOL (ACIOL) (two patients) and resuturing of a PCIOL in a different meridian (one patient). Follow-up ranged from 4 to 36 months, median 19.5 months, starting from the time of the initial postsuturing vitreous hemorrhage. Final vision ranged from 20/20 to hand motions, with four eyes having 20/40 or better vision. Endoscopy revealed a haptic embedded into the pars plicata in one eye but no evidence of neovascularization. Recurrent vitreous hemorrhage may occur as a complication of scleral suturing of PCIOL. The etiology of these hemorrhages does not appear to be related to neovascular proliferation at the haptic suture site, but may be secondary to erosion of the haptic into uveal structures. Not all eyes require reoperation after these hemorrhages; however, good visual results may be achieved by replacing the sutured PCIOL with an ACIOL or by suturing the PCIOL in a different meridian.

  2. Vest-over-Pant Method for Closure of Residual Cavity of Liver Hydatid Cyst

    Directory of Open Access Journals (Sweden)

    Saba Behdad

    2012-01-01

    Full Text Available Objective. Although several therapeutic strategies have proven to be effective for hydatid cyst of liver, but surgery is still the most common therapy despite its morbidity and mortality. Furthermore, a variety of technique has been recommended for managing the residual cavity after cystectomy. We report here a new technical method for the reconstruction of hydatid cyst residual cavity with using overlapping flaps of liver edges (Vest over Pant. Methods. In this technique after removing the cyst, the edges of one side of cyst cavity were sutured to the base of the cavity using three to four mattress sutures, and edges of other side of liver was overlapped on the dorsal part of previous layer using four to five mattress sutures. Therefore residual cavity dead space was obliterated with two surfaces of cavity. Results. Fifty males were treated by our method. The average cyst volume was 423±110 mL. There was no intraabdominal sepsis, bile leakage, or hepatic necrosis. In follow-up ultrasound study, residual cavities were disappeared one month after operation. Conclusion. Overlapping flaps of liver edges (Vest over Pant provides easy, safe closure of cyst with preservation of the liver anatomy.

  3. A comparison of lateral ankle ligament suture anchor strength.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Crates, John M

    2013-06-01

    Lateral ankle ligament repairs increasingly use suture anchors instead of bone tunnels. Our purpose was to compare the biomechanical properties of a knotted and knotless suture anchor appropriate for a lateral ankle ligament reconstruction. In porcine distal fibulae, 10 samples of 2 different PEEK anchors were inserted. The attached sutures were cyclically loaded between 10N and 60N for 200 cycles. A destructive pull was performed and failure loads, cyclic displacement, stiffness, and failure mode recorded. PushLock 2.5 anchors failed before 200 cycles. PushLock 100 cycle displacement was less than Morphix 2.5 displacement (panchors completing 200 cycles was 86.5N (PushLock) and 252.1N (Morphix) (psuture breaking for all PushLocks while the Morphix failed equally by anchor breaking and suture breakage. The knotted Morphix demonstrated more displacement and greater failure strength than the knotless PushLock. The PushLock failed consistently with suture breaking. The Morphix anchor failed both by anchor breaking and by suture breaking. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  4. A New Coating for Non-resorbable Surgical Suture

    Directory of Open Access Journals (Sweden)

    Ahmed Salah Hameed

    2017-12-01

    Full Text Available Suture is a biomaterial used to approximate wound edges to facilitate the healing process. This task could be compromised as a result of wound infection. Zinc is an element that has antibacterial action and can be a member of silicate glasses. The zinc-silicate glasses can be used as a coating for surgical suture to combat wound infection. However, zinc has a negative effect on glass degradation and its  antibacterial action is a pH sensitive. In this work, silicate glasseswith ZnO at 14 and 17 mole% were used as a coating for non-resorbable Mersilk suture using a slurry-dipping technique. The coating morphology was studied using SEM and itsanti-bacterial action was investigated in vitroagainstgram positive and negative bacteria at neutral and acidic conditions.The effect of the coating on tensile strength of the sutures wasstudied as well.The results revealed that the coatingwas well-adhered to the suture and had anti-bacterial action atacidic condition.The coating had no effect on the tensile strength of the surgical suture

  5. Development of braided drug-loaded nanofiber sutures

    Energy Technology Data Exchange (ETDEWEB)

    Hu Wen [School of Materials Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Huang Zhengming [School of Aerospace Engineering and Applied Mechanics, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Liu Xiangyang, E-mail: huangzm@tongji.edu.cn [Department of Physics, National University of Singapore, 2 Science Drive 3, 117542 (Singapore)

    2010-08-06

    The objectives of this work are twofold. Firstly, while most work on electrospinning is limited to the development of only functional materials, a structural application of electrospun nanofibers is explored. Secondly, a drug-loaded tissue suture is fabricated and its various properties are characterized. Braided drug-loaded nanofiber sutures are obtained by combining an electrospinning process with a braiding technique followed by a coating procedure. Two different electrospinning techniques, i.e. blend and coaxial electrospinning, to incorporate a model drug cefotaxime sodium (CFX-Na) into poly(L-lactic acid) (PLLA) nanofibers have been applied and compared with each other. Properties of the braided drug-loaded sutures are characterized through a variety of methods including SEM, TEM and tensile testing. The results show that the nanofibers had a preferable micromorphology. The drug was incorporated into the polymer nanofibers homogeneously, with no cross-linking. The nanofibers maintained their fibrous structures. An in vitro release study indicates that the drug-loaded nanofibers fabricated by blend electrospinning and coaxial electrospinning had a different drug release behavior. An inhibition zone experiment shows that both sutures obtained from the nanofibers of the different electrospinning techniques had favorable antibacterial properties. The drug-loaded sutures had preferable histological compatibility performance compared with commercial silk sutures in an in vivo comparative study.

  6. 27 CFR 27.62 - Affixing closures.

    Science.gov (United States)

    2010-04-01

    ... OF THE TREASURY LIQUORS IMPORTATION OF DISTILLED SPIRITS, WINES, AND BEER General Requirements Closures for Containers of Distilled Spirits § 27.62 Affixing closures. Closures or other devices on containers of imported distilled spirits having a capacity of 1 gallon (3.785 liters) or less shall be...

  7. Constraining the location of the Archean--Proterozoic suture in the Great Basin based on magnetotelluric soundings

    Science.gov (United States)

    Rodriguez, Brian D.; Sampson, Jay A.

    2012-01-01

    It is important to understand whether major mining districts in north-central Nevada are underlain by Archean crust, known to contain major orogenic gold deposits, or, alternatively, by accreted crust of the Paleoproterozoic Mojave province. Determining the location and orientation of the Archean-Proterozoic suture zone between the Archean crust and Mojave province is also critical because it may influence subsequent patterns of sedimentation, deformation, magmatism, and hydrothermal activity. In the Great Basin, the attitude of the suture zone is unknown because it is concealed below cover. A regional magnetotelluric sounding profile along the Utah-Nevada State line reveals a deeply penetrating, broad electrical conductor that may be the Archean-Proterozoic suture zone in the northwest corner of Utah. This major crustal conductor's strike direction is northwest, where it broadens to about 80 km wide below about 3-km depth. These results suggest that the southwestern limit of intact Archean crust in this part of the Great Basin is farther north than previously reported. These results also suggest that the major gold belts in north-central Nevada are located over the Paleoproterozoic Mojave province, and the Archean terrain lies northeast in the northwest corner of Utah. Rifted Archean crust segments south and west of the suture suggest that future mineral exploration northeast of current mineral trends may yield additional gold deposits.

  8. Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy

    Science.gov (United States)

    Sull, Alan; Inceoglu, Serkan; August, Alicia; Gregorius, Stephen; Wongworawat, Montri D.

    2016-01-01

    Background: Barbed suture use has become more popular as technology and materials have advanced. Minimal data exist regarding performance of the 2 commercially available products, V-LocTM and StratafixTM in tendon repairs. The purpose of this study was to compare gap resistance and ultimate tensile strength of both suture materials and nonbarbed suture in a porcine ex vivo model. Methods: Porcine flexor tendons were harvested and divided into 3 groups of 10 of varying suture material (3-0 PDS™, 3-0 V- V-Loc 180™, or 3-0 Stratafix™). A modified 4-strand cruciate technique was used to repair each tendon. Knotless repair was performed using barbed suture, whereas a buried 6-throw square knot was done using conventional suture. A servohydrolic tester was used for biomechanical testing of linear 2-mm gap resistance and maximum tensile strength. Results: No difference was found in 2-mm gap resistance among the 3 groups. No difference was found in ultimate tensile strength between V-Loc™ (76.0 ± 9.4 N) and Stratafix™ (68.1 ± 8.4 N) repairs, but the ultimate strength of the PDS™ control group (83.4 ± 10.0 N) was significantly higher than that of Stratafix™. Conclusions: Barbed (knotless) and nonbarbed suture repairs demonstrate equivalent 2-mm gap resistance. Stratafix™ repairs show slightly inferior performance to nonbarbed repairs in ultimate tensile strength, although this occurred at gap distances far beyond the 2-mm threshold for normal tendon gliding. Both barbed and nonbarbed 4-strand cruciate flexor tendon repairs may require peripheral repair to withstand physiologic loads. PMID:28149217

  9. Effects of wound architecture and suture technique on postoperative astigmatism.

    Science.gov (United States)

    Gimbel, H V; Sun, R; DeBroff, B M

    1995-01-01

    A prospective randomized investigation was performed to evaluate the effects of wound architecture and suture techniques on postoperative astigmatism after phacoemulsification and intraocular lens implantation. Two hundred eyes with preexisting with-the-rule astigmatism were randomized into four groups: (1) sutureless scleral tunnel frown incision, (2) scleral tunnel frown incision with a horizontal suture, (3) scleral tunnel frown incision with both a horizontal and a running suture, and (4) posterior limbal acute beveled cataract incision with a running suture. All the incisions were placed in the vertical steep meridian. Data were analyzed from 128 cases with 1-year follow-up. The results revealed that at the 2-month postoperative visit, preexisting astigmatism was significantly reduced in group 1 (P = .029) and significantly increased in groups 3 (P = .020) and 4 (P = .005). There was no significant change in group 2 (P = .06). By the 1-year postoperative visit, there was no significant difference in astigmatism from preoperative levels for all four groups. Vector analysis revealed no significant difference in the mean surgically induced cylinder at 1 year in all four groups. The number of eyes with induced against-the-rule astigmatism, however, was significantly higher than the number of eyes with induced with-the-rule astigmatism in all four groups (P sutured wounds placed in the vertical steep meridian may initially increase with-the-rule astigmatism, whereas nonsutured wounds placed in the vertical steep meridian may initially reduce with-the-rule astigmatism. By 1 year, however, a mean flattening of the vertical steep meridian was observed in the three groups with sutures as well as in the group without sutures.

  10. Mesh fixation with a barbed anchor suture results in significantly less strangulation of the abdominal wall.

    Science.gov (United States)

    Lyons, Calvin; Joseph, Rohan; Salas, Nilson; Reardon, Patrick R; Bass, Barbara L; Dunkin, Brian J

    2012-05-01

    Laparoscopic ventral hernia repair using an underlay mesh frequently requires suture fixation across the abdominal wall, which results in significant postoperative pain. This study investigates the utility of a novel mesh fixation technique to reduce the strangulation force on the abdominal wall. Multiple 2-cm(2) pieces of polyester mesh (Parietex Composite, Covidien) were placed as an underlay against a porcine abdominal wall. Fixation was accomplished using either the standard 0-polyglyconate or the 0-polyglyconate barbed anchor suture designed to hold in tissue without the need to tie a knot (V-Loc 180; Covidien). Suture fixation began with a stab wound incision in the skin. A suture-passing device then was used to pass the suture across the abdominal wall and through the mesh. The suture passer was removed and reintroduced through the same stab wound incision but at a different fascial entry point 1.5 cm away. The tail of the suture was grasped and pulled up through both the mesh and the abdominal wall, creating a full-thickness U-stitch. One tail of the suture was attached to a tensiometer, and the strangulation force on the abdominal wall was measured while the suture was tied (standard) or looped (barbed). To compare pullout force, the tensiometer was attached to either the mesh or the suture, and traction was applied until material failure or suture pull through. Results are expressed as mean ± standard deviation. Comparisons were performed using Student's t-test. Eight pieces of mesh were placed for each suture. The average force required to secure the barbed suture (0.59 ± 0.08 kg) was significantly less than the force needed to secure the standard suture (2.17 ± 0.58 kg) (P suture pullout forces with the mesh failure forces. Although the pullout force for the standard suture is significantly greater than for the barbed suture, both sutures have a pullout strength significantly greater than the mesh failure force. Table 1 Suture fixation forces for

  11. The effect of different suturing techniques on astigmatism after penetrating keratoplasty.

    Science.gov (United States)

    Kim, Sang Jin; Wee, Won Ryang; Lee, Jin Hak; Kim, Mee Kum

    2008-12-01

    The purpose of this study was to compare the effects on astigmatism after penetrating keratoplasty with three different suture techniques. In this prospective study, 38 eyes of 38 patients underwent penetrating keratoplasty with three suturing techniques: interrupted, single running, and double running. Topographic astigmatism was measured at 2, 6, 12, and 18 months after keratoplasty. During 18 months after surgery, the interrupted suture group had higher astigmatism than the double running suture group. There was no significant difference in the amounts of astigmatism during the first year after keratoplasty between the single running and the double running suture group. However, at 18 months after surgery, when all sutures were out, the double running suture group (3.60+/-1.58 diopters) showed significantly less astigmatism than the single running group (5.65+/-1.61 diopters). In conclusion, post-keratoplasty astigmatism was the least in the double running suture group of the three suturing techniques at 18 months after penetrating keratoplasty.

  12. Positioning of the cross-stitch on the modified Kessler core tendon suture.

    Science.gov (United States)

    Gil-Santos, L; Monleón-Pradas, M; Gomar-Sancho, F; Más-Estellés, J

    2018-01-26

    Cryopreserved human tendons were sutured with different variations of a modified Kessler-type grasping suture in a series of different designs in order to assess the influence of the distance between the cross-stitch on the core suture (5 and 10 mm from the cut tendon edge) on the peripheral suture. An original mathematical model was employed to explain the mechanical behavior (strength, deformation, and distribution of load) of the different suture designs. The effect of the peripheral epitendinous suture, combined with the distance of the core suture, was evaluated. The variation of core suture distance had no relevant consequences on the overall resilience of the design. However, increasing the distance between the cross-stitches of the core suture reduces the deformation that is absorbed not only by the core suture itself but also by the peripheral suture. Adding a peripheral epitendinous suture to a 10-mm design almost doubles the breaking load in absolute values. The mathematical model predicts that the peripheral suture will support a greater load when the distance of the core suture cross-stitches is increased. The evidence level is II. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Effect of Additional Sutures per Suture Anchor in Arthroscopic Bankart Repair: A Review of Single-loaded Versus Double-loaded Suture Anchors.

    Science.gov (United States)

    Chen, Jeffrey S; Novikov, David; Kaplan, Daniel J; Meislin, Robert J

    2016-07-01

    To directly compare single-loaded suture anchors (SSA) with double-loaded suture anchors (DSA) to help surgeons optimize the operative technique, time, and cost of Bankart repairs. A literature review was performed using the PubMed and SCOPUS databases. Studies that directly compared SSA and DSA for Bankart repairs, or indirectly compared them by collecting relevant data despite a different objective, were included. A total of two studies were included, both of which were cadaveric laboratory studies. A total of 28 shoulders were tested. Tests conducted include loading to failure and cyclic loading. One study found SSA to be biomechanically equivalent to DSA, and one found DSA to be superior. Based on limited cadaveric study, DSA are at least equivalent biomechanically to SSA, and may be superior. By using DSA, surgeons create repair constructs that are as strong as, or stronger than, those made with SSA, but with fewer anchors. This reduces the amount of holes drilled and implants placed in the glenoid, while also minimizing cost. Quantifying the benefit of additional sutures in a suture anchor can help optimize the quality of repair, time, and cost in arthroscopic shoulder repair. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of Postoperative Povidone-Iodine in Adjustable Suture Strabismus Surgery to Reduce Suture Colonization: A Randomized Clinical Trial.

    Science.gov (United States)

    Rossetto, Julia D; Suwannaraj, Sirinya; Cavuoto, Kara M; Spierer, Oriel; Miller, Darlene; McKeown, Craig A; Capo, Hilda

    2016-10-01

    Although the association between suture colonization and postoperative infections remains hypothetical, measures to reduce perioperative suture colonization may minimize postoperative infections. The suture colonization rate in adjustable suture strabismus surgery is not well defined, and the effect of povidone-iodine use on suture colonization is unknown. To assess whether povidone-iodine application at the end of adjustable suture strabismus surgery decreases the suture colonization rate. In this randomized clinical trial designed in 2015 and performed from June 1 through October 31, 2015, a total of 65 adjustable and 43 control suture specimens from 65 demographically similar adults undergoing adjustable suture strabismus surgery were studied. A random sampling assigned participants into group 1 (with povidone-iodine) or group 2 (without povidone-iodine) at the end of surgery. A control suture specimen was obtained if ipsilateral nonadjustable surgery was performed. Both groups received antibiotic ointment at the end of the procedure. No patients refused participation or withdrew. Data analysis was performed from October 1 to December 31, 2015. Observers were unaware of patient grouping. One drop of 5% povidone-iodine directly over the sliding noose of the adjustable suture at the end of surgery. The suture colonization rate after adjustment in group 1, group 2, and the control group. Of 65 adults undergoing surgery, there were 17 men (49%) and 18 women (51%) in group 1 and 10 men (33%) and 20 women (67%) in group 2, as well as 20 men (47%) and 23 women (53%) in the control group. The mean (SD) age of the patients was 48.5 (16.8) years in group 1, 46.6 (18.1) years in group 2, and 47.7 (17.0) years in the control group. There was no difference in the colonization rate between group 1 (57%) and group 2 (47%) (relative risk [RR], 1.1; 95% CI, 0.6-1.7; P = .80), group 1 and the control group (44%) (RR, 1.0; 95% CI, 0.5-1.8; P > .99), or group 2 and

  15. Pediatric high speed digital imaging of vocal fold vibration: A normative pilot study of glottal closure and phase closure characteristics

    Science.gov (United States)

    Patel, Rita R.; Dixon, Angela; Richmond, AnnaMary; Donohue, Kevin D.

    2012-01-01

    Objective The aim of the study is to characterize normal vibratory patterns of both glottal closure and phase closure in the pediatric population with the use of high speed digital imaging. Methods For this prospective study a total of 56 pre-pubertal children, 5–11 years (boys = 28, girls = 28) and 56 adults, 21–45 years (males = 28, females = 28) without known voice problems were examined with the use of a new technology of high speed digital imaging. Recordings were captured at 4000 frames per second for duration of 4.094 seconds at participants’ typical phonation. With semi-automated software, montage analysis of glottal cycles was performed. Three trained experienced raters, rated features of glottal configuration and phase closure from glottal cycle montages. Results Posterior glottal gap was the predominant glottal closure configuration in children (girls = 85%, boys = 68%) with normal voice. Other glottal configurations observed were: anterior gap (girls = 3.6%, boys = 0%), complete closure (girls = 7%, boys = 10%), hour glass (girls = 0%, boys = 11%). Adults with normal voice also demonstrated predominantly higher percentage of posterior glottal gap configuration (females = 75% male = 54%) compared to the configurations of anterior gap (females = 0% male = 7%), complete closure (females = 2% male = 39%), hour glass (females = 3.6% male = 3.6%). A predominantly open phase (51–70% of the glottal cycle) was observed in 86% girls and 71% boys. Compared to children, adult females showed a predominantly balance phased closure 46%, followed by open phase (39%) and predominantly closed phase (14%). Adult males showed a predominantly closed phase (43%), followed by predominantly open phase (39%), followed by a balanced phase (18%). Conclusions This is a first study investigating characteristics of normal vibratory motion in children with high speed digital imaging. Glottal configuration and phase closure for children with normal voices are distinctly

  16. Systematic review and meta-analysis of sutures coated with triclosan for the prevention of surgical site infection after elective colorectal surgery according to the PRISMA statement.

    Science.gov (United States)

    Sandini, Marta; Mattavelli, Ilaria; Nespoli, Luca; Uggeri, Fabio; Gianotti, Luca

    2016-08-01

    Several randomized clinical trials (RCTs) conducted to evaluate the effect of triclosan-coated suture on surgical site infection (SSI) yield to controversial results. The primary purpose of this systematic review and meta-analysis was to analyze the available RCTs, comparing the effect of triclosan-coated suture with uncoated suture on the incidence of SSI after elective colorectal operations. As secondary endpoint of the analysis, we considered length of hospital stay after surgery. We performed a systematic literature review through Medline, Embase, Pubmed, Scopus, Ovid, ISI Web of Science, and the Cochrane Controlled Trials Register searching for RCTs published from 1990 to 2015. To conduct these meta-analyses, we followed the guidelines and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Study inclusion criteria were as follows: parallel-group RCTs in adult populations reporting the closure of the abdominal wall after elective colorectal operation with triclosan-coated suture or noncoated suture, and reporting the outcomes considered in the meta-analysis. Six trials including 2168 patients (1102 treated and 1066 controls) provided data on SSIs. The overall rate was 11.7% (129/1102) in the triclosan group and 13.4% (143/1066) in the control group (odds ratio 0.81, 95% confidence interval [CI] 0.58-1.13, P = 0.220). Heterogeneity among studies was moderate (I = 44.9%). No evidence of publication bias was detectable. Five RCTs (1783 patients; 914 treated and 689 controls) described hospital length of stay with no significant effect (mean difference: -0.02, 95% CI -0.11 to -0.07, P = 0.668). The I test for heterogeneity was 0% (P = 0.836). Moderator analyses showed no significant differences were detected in analyses comparing the suture materials (polydioxanone vs polyglactin). In open-label trials, the odds ratio for SSI risk was 0.62 (95% CI 0.20-1.93, P = 0.413), 0.77 in single-blind (95% CI 0.31-1.95, P

  17. Suture anchor materials, eyelets, and designs: update 2008.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Beavis, R Cole; Barrera Oro, Fernando

    2008-08-01

    Our purpose was to evaluate recently introduced sutures and suture anchors for single pull load to failure strength and failure mode. Suture anchors were tested in fresh porcine metaphyseal cortex and cancellous troughs using an established protocol. An Instron machine applied tensile loads parallel to the axis of insertion at a rate of 12.5 mm per second until failure and mean anchor failure strengths were calculated. The mode of failure was recorded (anchor pullout, suture eyelet cut out, or suture failure). Anchors tested included the Kinsa, Kinsa RC, BioRaptor 2.3 PK, TwinFix PK FT 5.5 and 6.5, BioCleat, Healix Peek, VersaLok, BioKnotless, BioKnotless BR, Corkscrew FT III, SwiveLock C, and PEEK SutureTak. The mean cortical failure loads were as follows: Kinsa (219 N), Kinsa RC (222 N), BioRaptor 2.3 PK (172 N), TwinFix PK FT 5.5 (491 N) and 6.5 (503 N), BioCleat (218 N), Healix Peek (407 N), VersaLok (376 N), BioKnotless (249 N), BioKnotless BR (265 N), Corkscrew FT III (386 N), SwiveLock C (712 N), and PEEK SutureTak (168 N). Pullout was the predominant failure mode for the VersaLok, BioKnotless, BioKnotless BR, and BioRaptor 2.3PK anchors. Eyelet failure was the predominant failure mode for the Kinsa, Kinsa RC, BioCleat, Healix Peek, Corkscrew FT III, SwiveLock C, and PEEK SutureTak. The newer anchors showed markedly increased load to failure strengths. Two or more high-strength sutures are commonly used as well as new anchor materials (PEEK and Biocryl Rapide), new eyelet designs, and the increased use of a "knotless" concept. An anchor which fails principally by pull out at a low load to failure is at risk for creating an intra-articular loose body.

  18. Arthroscopic Transtendinous Biceps Tenodesis With All-Suture Anchor.

    Science.gov (United States)

    Shih, Chien-An; Chiang, Florence L; Hong, Chih-Kai; Lin, Cheng-Wei; Wang, Ping-Hui; Jou, I-Ming; Su, Wei-Ren

    2017-06-01

    There are several methods for long head of the biceps (LHB) tenodesis, yet the optimal option is still debatable. Here we introduce a technique for arthroscopic suprapectoral biceps tenodesis with an all-suture anchor, the transtendinous biceps tenodesis technique. The LHB tenodesis is performed by using the Y-Knot anchor (1.3-mm). A standard suprapectoral approach is used for the tenodesis. A 1.3-mm drill bit is used to drill through the midportion of the biceps tendon and underlying bone to make a pilot hole. Next, the Y-Knot anchor is passed through the tendon and anchored on the underlying bone. A wrapping suture technique is then used to wrap around, tension, and secure the LHB tendon with the aid of a shuttling polydioxanone suture. The construct is fixed by tying down both suture limbs in a nonsliding fashion. This Technical Note describes an alternative method for all-arthroscopic suprapectoral biceps tenodesis using an all-suture anchor with a small diameter to minimize trauma to the tendon.

  19. EFFECTS OF DIFFERENT SUTURE MATERIALS ON TISSUE HEALING

    Directory of Open Access Journals (Sweden)

    Fırat SELVİ

    2016-01-01

    Full Text Available Purpose: The purpose of this study was to investigate the healing differences in between four different widely used suture materials in the oral surgery practice, including silk (Perma- Hand; Ethicon, INC., Somerville, NJ, USA, polypropylene (Prolene; Ethicon, INC., Somerville, NJ, USA, coated polyglactin 910 (Ethicon, INC., Somerville, NJ, USA. and polyglecaprone 25 (Ethicon, INC., Somerville, NJ, USA . Materials and Methods: 20 male rats were randomly allocated into two groups depending on their sacrification days (post-operative 1st and the 7th days. Four longitudinal incision wounds, each 1cm in size, were created on the dorsum of each animal which were then primarily closed with four different types of sutures. Results: The effects of these suture materials on soft tissue healing were compared histopathologically, by means of density of the cells, necrosis, fibrosis, foreign body reaction, the presence of cells of acute and chronic infection. No statistically significant difference was observed between the groups regarding the density of the cells, necrosis, fibrosis, foreign body reaction, and the presence of the cells of acute & chronic infections. Of note, propylene showed slightly less tissue reaction among the other materials. Conclusion: The results of our study showed that there is no only one ideal suture material for surgical practice. The factors related to the patient, the type of the surgery and the quality of the tissue are important to decide an appropriate suture material.

  20. Recognizing surgeon's actions during suture operations from video sequences

    Science.gov (United States)

    Li, Ye; Ohya, Jun; Chiba, Toshio; Xu, Rong; Yamashita, Hiromasa

    2014-03-01

    Because of the shortage of nurses in the world, the realization of a robotic nurse that can support surgeries autonomously is very important. More specifically, the robotic nurse should be able to autonomously recognize different situations of surgeries so that the robotic nurse can pass necessary surgical tools to the medical doctors in a timely manner. This paper proposes and explores methods that can classify suture and tying actions during suture operations from the video sequence that observes the surgery scene that includes the surgeon's hands. First, the proposed method uses skin pixel detection and foreground extraction to detect the hand area. Then, interest points are randomly chosen from the hand area so that their 3D SIFT descriptors are computed. A word vocabulary is built by applying hierarchical K-means to these descriptors, and the words' frequency histogram, which corresponds to the feature space, is computed. Finally, to classify the actions, either SVM (Support Vector Machine), Nearest Neighbor rule (NN) for the feature space or a method that combines "sliding window" with NN is performed. We collect 53 suture videos and 53 tying videos to build the training set and to test the proposed method experimentally. It turns out that the NN gives higher than 90% accuracies, which are better recognition than SVM. Negative actions, which are different from either suture or tying action, are recognized with quite good accuracies, while "Sliding window" did not show significant improvements for suture and tying and cannot recognize negative actions.

  1. Selective laser vaporization of polypropylene sutures and mesh

    Science.gov (United States)

    Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.

    2012-02-01

    Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.

  2. Geographic Concentration and Correlates of Nursing Home Closures: 1999–2008

    Science.gov (United States)

    Feng, Zhanlian; Lepore, Michael; Clark, Melissa A.; Tyler, Denise; Smith, David B.; Mor, Vincent; Fennell, Mary L.

    2013-01-01

    Background While demographic shifts project an increased need for long-term care for an aging population, hundreds of nursing homes close each year. We examine whether nursing home closures are geographically concentrated and related to local community characteristics such as the racial and ethnic population mix and poverty. Methods National Online Survey Certification and Reporting data were used to document cumulative nursing facility closures over a decade, 1999 through 2008. Census 2000 zip code level demographics and poverty rates were matched to study facilities. The weighted Gini coefficient was used to measure geographic concentration of closures, and geographic information system maps to illustrate spatial clustering patterns of closures. Changes in bed supply due to closures were examined at various geographic levels. Results Between 1999 and 2008, a national total of 1776 freestanding nursing homes closed (11%), compared with 1126 closures of hospital-based facilities (nearly 50%). Combined, there was a net loss of over 5% of beds. The relative risk of closure was significantly higher in zip code areas with a higher proportion of blacks or Hispanics or a higher poverty rate. The weighted Gini coefficient for closures was 0.55 across all metropolitan statistical areas and 0.71 across zip codes. Closures tended to be spatially clustered in minority-concentrated zip codes around the urban core, often in pockets of concentrated poverty. Conclusions Nursing home closures are geographically concentrated in minority and poor communities. Since nursing home use among the minority elderly population is growing while it is declining among whites, these findings suggest that disparities in access will increase. PMID:21220642

  3. Effect of robotic manipulation on unidirectional barbed suture integrity: evaluation of tensile strength and sliding force.

    Science.gov (United States)

    Kaushik, Dharam; Clay, Kevin; Hossain, S G M; Park, Eugene; Nelson, Carl A; LaGrange, Chad A

    2012-06-01

    One of the more challenging portions of robot-assisted radical prostatectomy (RARP) is the urethrovesical anastomosis. Because of this, a unidirectional absorbable barbed suture (V-Loc(™)) has been used to complete the anastomosis with better efficiency and less tension. The effect of robotic needle driver manipulation on barbed suture is unknown. Therefore, the aim of this study is to determine whether robotic manipulation decreases the tensile strength and peak sliding force of V-Loc barbed suture. Fifty-six V-Loc sutures were compared with 56 Maxon sutures. All sutures were 3-0 caliber. Half of the sutures in each group were manipulated with a da Vinci(®) robot large needle driver five times over a 5 cm length of suture. The other half was not manipulated. Breaking force was determined by placing sutures in a Bose ElectroForce load testing device. For sliding force testing, 28 V-Loc sutures were manipulated in the same fashion and compared with 28 nonmanipulated V-Loc sutures. Peak force needed to make the suture slip backward in porcine small intestine was determined to be the sliding force. Scanning electron microscopy of the barbs before and after robotic manipulation was also performed. The mean difference in breaking forces for manipulated vs nonmanipulated Maxon sutures was 4.52 N (P=0.004). The mean difference in breaking forces for manipulated vs nonmanipulated V-Loc sutures was 1.30 N (P=0.046). The manipulated V-Loc group demonstrated a lower peak sliding force compared with the nonmanipulated group (0.76 vs 0.88 N, P=0.199). Electron microscopy revealed minor structural damage to the barbs and suture. Tensile strength and peak sliding force of V-Loc suture is decreased by robotic manipulation. This is likely because of structural damage to the suture and barbs. This structural damage, however, is likely not clinically significant.

  4. The Stress Relaxation Process in Sutures Tied with a Surgeon's Knot in a Simulated Biological Environment.

    Science.gov (United States)

    Liber-Kneć, Aneta; Łagan, Sylwia

    2016-01-01

    The exact characteristics of sutures are not only the basis for selecting from among different types of suture, but also provide the necessary information for the design of new surgical sutures. Apart from information relating to the breaking load of a suture reported in pharmacopoeias, the viscoelastic properties of sutures can be an additional selection criterium - one that influences stitching quality, especially when there is a risk of wound dehiscence. The aim of the study was to assess the stress relaxation process for 3 polymeric sutures in an environment simulating the conditions in a living organism and (for comparison) in room conditions. Stress relaxation testing was carried out on 3 polymeric sutures: polypropylene (PP), polydioxanone (PDS) and polyglycolic acid (PGA). To identify the mechanical properties of the sutures, uniaxial tensile tests were conducted according to the Polish Pharmacopoeia. The relaxation test was carried out in room conditions and in the bath simulating a biological environment. The sutures being tested were tied with a surgeon's knot. The PP suture exhibited the greatest stress relaxation (18% of the initial stress in room conditions and 21% of the initial stress in the bath). The PGA suture exhibited the least stress relaxation (approximately 60% of the initial stress in room conditions and 59% of the initial stress in the bath). The PDS suture was tested at a lower strain level and showed stress relaxation similar to the PGA suture (approximately 63% of the initial stress in room conditions and 55% in the bath). Multifilament braided absorbable (PGA) sutures and monofilament absorbable (PDS) sutures had a higher stress relaxation ratio over time than monofilament non-absorbable (PP) sutures. These findings may indicate higher stress maintained over time in PDS and PGA sutures, and thus higher tension at wound edges, sufficient to resist wound dehiscence.

  5. Biocompatibility and biomechanical analysis of elastic TPU threads as new suture material.

    Science.gov (United States)

    Vogels, Ruben R M; Lambertz, Andreas; Schuster, Philipp; Jockenhoevel, Stefan; Bouvy, Nicole D; Disselhorst-Klug, Catherine; Neumann, Ulf P; Klinge, Uwe; Klink, Christian D

    2017-01-01

    High suture tension is one of the causes for many wound-healing problems. Constriction of tissue within the suture loops of nonelastic sutures can lead to cutting of the suture through tissues and necrosis of the tissue within these loops. The use of elastic materials in new suture types could give the material the ability to adapt tension to the tissue requirements and subsequently lead to more vital tissue within its loops. We evaluated the foreign body host response, as indicator of biocompatibility, to a new thermoplastic poly(carbonate) urethane (TPU) synthetic suture material in a rat model compared with standard nonelastic polypropylene (PP) sutures. Tissue samples were collected at 7 and 21 days, and host response was evaluated. Subsequently, suture tension curves of the new elastic sutures for the first 30 min after knotting were recorded in a pig model. The new TPU sutures showed an improved foreign body response when compared with that of PP, with a reduction in the amount of macrophages surrounding the material. Tension experiments showed a superior tension curve for TPU sutures, with a major reduction in peak suture tension when compared with that of standard PP sutures, while still retaining adequate tension after 30 min. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 99-106, 2017. © 2015 Wiley Periodicals, Inc.

  6. Interrupted or continuous-intradermal suturing? Statistical analysis of postoperative scars

    Directory of Open Access Journals (Sweden)

    Elif Sarı

    2014-12-01

    Full Text Available Background and Design: Postoperative scar development is an important problem for patients treated in plastic surgery clinics. Most patients think that continuous intradermal suturing is superior to interrupted suturing because they assume that it creates less scarring. We evaluated scars that form following intradermal and interrupted suturing. This article presents our controlled study that objectively compared the scars on patients' faces using a wound evaluation scale. Materials and Methods: Thirty-five patients, who had undergone operations on the bilateral cheeks, were included in this study. Thirty patients were female; five patients were male. Their mean age was 40.05 years. The average scar evaluation time after surgery was 9.05 months. Elliptical excisions were made on the lesions under local anesthesia. The incisions on the right cheeks were sutured with 6/0 monofilament nonabsorbable sutures using the continuous intradermal suturing technique. The left cheek incisions were sutured with same sutures using the interrupted suturing method. Results: The patients were evaluated 7–11 months after operation (mean: 9.05 months using the Stony Brook Scar Evaluation Scale. A Related Samples T-test was used for statistical evaluation of the differences between the suturing techniques. No significant differences were noted in scar formation between the two suturing methods (p>0.05. Conclusion: We found no differences in scar formation between the two frequently used suturing techniques studied here. We believe that the suturing technique is a less important determinant of scar formation than are other factors.

  7. Triangular mattress suture in abdominal diastasis to prevent epigastric bulging.

    Science.gov (United States)

    Ferreira, L M; Castilho, H T; Hochberg, J; Ardenghy, M; Toledo, S R; Cruz, R G; Tardelli, H

    2001-02-01

    In the classic abdominoplasty, the treatment of large diastasis recti with simple or vertical mattress sutures may result in a nonaesthetic bulge. The surgeon may produce a craniocaudal bulge deformity by treating the flaccidity in the horizontal plane only, although it occurs in all directions. The authors describe the triangular mattress suture for the treatment of large diastasis recti, and demonstrate the mechanism involved in producing an epigastric bulge. Also presented is their clinical experience with 56 patients, with a 3-year follow-up, using this new plication method. The triangular mattress suture is a simple, quick, and effective way to correct abdominal diastasis and to avoid the epigastric bulge deformity with no added morbidity.

  8. Closure Devices for Iatrogenic Thoraco-Cervical Vascular Injuries

    Energy Technology Data Exchange (ETDEWEB)

    Makris, Gregory C., E-mail: g.makris09@doctors.org.uk; Patel, Rafiuddin; Little, Mark; Tyrrell, Carina; Sutcliffe, James; Allouni, Kader; Bratby, Mark; Anthony, Susan; Uberoi, Raman [Oxford University Hospitals, NHS Foundation Trust, Interventional Radiology Department (United Kingdom)

    2017-03-15

    IntroductionThe unintentional arterial placement of a central venous line can have catastrophic complications. The purpose of this systematic review is to assess and analyse the available evidence regarding the use of the various vascular closure devices (VCDs) for the management of iatrogenic thoraco-cervical arterial injuries (ITCAI).MethodsA systematic review was performed according to PRISMA guidelines.ResultsThirty-two relevant case series and case reports were identified with a total of 69 patients having being studied. In the majority of the studies, plug-based VCDs were used (81%) followed by suture-based devices (19%). The majority of studies reported successful outcomes from the use of VCDs in terms of achieving immediate haemostasis without any acute complications. Long-term follow-up data were only available in nine studies with only one case of carotid pseudoaneurysm being reported after 1-month post-procedure. All other cases had no reported long-term complications. Five studies performed direct or indirect comparisons between VCDs and other treatments (open surgery or stent grafting) suggesting no significant differences in safety or effectiveness.ConclusionAlthough there is limited evidence, VCDs appear to be safe and effective for the management of ITCAIs. Further research is warranted regarding the effectiveness of this approach in comparison to surgery and in order to identify those patients who are more likely to benefit from this minimally invasive approach.

  9. Meaningful assessment method for laparoscopic suturing training in augmented reality.

    Science.gov (United States)

    Botden, Sanne M B I; de Hingh, I H J T; Jakimowicz, J J

    2009-10-01

    To be an effective training tool, a laparoscopic simulator has to provide metrics that are meaningful and informative to the trainee. Time, path length and smoothness are often used parameters, but are not very informative on the quality of the performance. This study aims to validate a newly developed assessment method for laparoscopic suturing on the ProMIS augmented reality simulator, and compares it with scores of objective observers. Twenty-four participants practised their suturing skills on the augmented reality suturing module: experienced participants (n = 10), >50 clinical laparoscopic suturing experience; and novice participants (n = 14), without laparoscopic experience. The performances were recorded and assessed by two unrelated observers and compared with the assessment scores. The assessment score was a calculation of time spent in the correct area and quality (strength) of the knot. To test the accuracy of the individual assessment parameters, we compared these with each other. The experienced participants had significantly higher performance scores than the novice participants in the beginner-level mode (mean 95.73 vs. 60.89, standard deviation 2.63 vs. 17.09, p < 0.001, independent t-test). The performance scores of the assessment method (n = 43) correlated significantly with the scorings of the objective observers (Spearman's rho 0.672; p < 0.001). The parameter time spent in correct area had a calculated significant correlation with the strength of the knot (n = 229, Spearman's rho 0.257, p < 0.001), but this was clinically irrelevant. This assessment method is a valid tool for objectively assessing laparoscopic suturing skills. Although assessment parameters can correlate, to provide informative feedback it is important to combine meaningful measurements in the assessment of suturing skills.

  10. Virtual interactive suturing for the Fundamentals of Laparoscopic Surgery (FLS).

    Science.gov (United States)

    Qi, Di; Panneerselvam, Karthikeyan; Ahn, Woojin; Arikatla, Venkata; Enquobahrie, Andinet; De, Suvranu

    2017-11-01

    Suturing with intracorporeal knot-tying is one of the five tasks of the Fundamentals of Laparoscopic Surgery (FLS), which is a pre-requisite for board certification in general surgery. This task involves placing a short suture through two marks in a penrose drain and then tying a double-throw knot followed by two single-throw knots using two needle graspers operated by both hands. A virtual basic laparoscopic skill trainer (VBLaST©) is being developed to represent the virtual versions of the FLS tasks, including automated, real time performance measurement and feedback. In this paper, we present the development of a VBLaST suturing simulator (VBLaST-SS©). Developing such a simulator involves solving multiple challenges associated with fast collision detection, response and force feedback. In this paper, we present a novel projection-intersection based knot detection method, which can identify the validity of different types of knots at haptic update rates. A simple and robust edge-edge based collision detection algorithm is introduced to support interactive knot tying and needle insertion operations. A bimanual hardware interface integrates actual surgical instruments with haptic devices enabling not only interactive rendering of force feedback but also realistic sensation of needle grasping, which realizes an immersive surgical suturing environment. Experiments on performing the FLS intracorporeal suturing task show that the simulator is able to run on a standard personal computer at interactive rates. VBLaST-SS© is a computer-based interactive virtual simulation system for FLS intracorporeal knot-tying suturing task that can provide real-time objective assessment for the user's performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. EVALUATION OF ADJUSTABLE SUTURE TECHNIQUE IN OUTCOME OF PTOSIS SURGERY

    Directory of Open Access Journals (Sweden)

    Nagaraju

    2015-10-01

    Full Text Available AIM: To evaluate the outcome of adjustable suture technique in ptosis surgery. INTRODUCTION : Surgical management of blepharoptosis is indicated in multiple situations and the post - operative outcomes can be as variable as the indications for surgery. Adjustable suture techniques in ptosis repair have been introduced and variable efficacies have been reported. MATERIALS AND METHODS: A retrospective case review of medical records from June 2010 to May 2011 (12 months of 5 eyes of 5 consecutive patients operated by a single surgeon at a Tertiary Eye care center in South India were reviewed. The clinical profile of patients included was r ecorded and results of adjustable suture technique described by Borman and collegues for these patients was reported. RESULTS: 5 eyes of 5 patients underwent adjustable suture ptosis repair in the study duration. 4 patients with moderate and 1 with severe ptosis, all having good levator function were diagnosed to have c ongenital ptosis in 3 cases and a cquired involutional ptosis in 2 cases. All 5 cases had a satisfactory outcome at day 4 post - operative after adjustment of lid height in the out - patient clini c. 1 patient with acquired involutional ptosis, identified with levator dehiscence intra - operatively had overcorrection at 6 months warranting re - surgery while the other 4 patients had satisfactory cosmetic lid height and functional outcome at 6 months fol low up after the adjustable suture technique for ptosis repair. CONCLUSION: Use of adjustable sutures in ptosis surgery can eliminate the intraoperative lid factors that can lead to unpredictable results. The technique described is easy to adapt and perfor m and can give repeatable and well acceptable results in the properly selected cases

  12. Retinal detachment caused by Arruga suture scleral intrusion. Treatment.

    Science.gov (United States)

    Sánchez-Vicente, J L; Rueda-Rueda, T; González-García, M L; López-Herrero, F; Sánchez-Vicente, P; Castilla-Lázpita, A

    2015-10-01

    We present the case of an 81-year-old man with retinal detachment caused by intrusion of an Arruga suture. The encircling buckle was located in the sub-retinal space and caused retinal breaks with retinal detachment A pars plana vitrectomy was performed along with intraocular cutting of the Arruga suture with retinal re-attachment. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Distal clavicular fracture treatment with suture anchor method

    OpenAIRE

    Mirbolook, Ahmadreza; Sadat, Mirmostafa; Golbakhsh, Mohammadreza; Mousavi, Mohammad Sadegh; Gholizadeh, Amirmohammad; Saghari, Sepehr

    2018-01-01

    Objective: The aim of this study was to evaluate the results of the suture anchor fixation in the treatment of distal clavicle fractures.Methods: This cross series study included 43 patients (27 males, 12 females; mean age: 40.1±10.18 years) with type II unstable distal clavicle fractures. The fractures were fixed by 2 pins and 1 suture anchor. All patients were followed at postoperative months 3, 6, and 12 and underwent clinical and radiographic evaluation after 1 year, ongoing at 6-month in...

  14. A biomechanical analysis of anterior Bankart repair using suture anchors.

    Science.gov (United States)

    Nho, Shane J; Frank, Rachel M; Van Thiel, Geoffrey S; Wang, Fan Chia; Wang, Vincent M; Provencher, Matthew T; Verma, Nikhil N

    2010-07-01

    Arthroscopic repair of anterior Bankart lesions is typically done with single-loaded suture anchors tied with simple stitch configuration. The knotless suture anchor will have similar biomechanical properties compared with two types of conventional suture anchors. Controlled laboratory study. Fresh-frozen shoulders were dissected and an anteroinferior Bankart lesion was created. For phase 1, specimens were randomized into either simple stitch (SSA) or knotless suture anchors (KSA) and loaded to failure. For phase 2, specimens were randomized into 1 of 4 repair techniques and cyclically loaded then loaded to failure: (1) SSA, (2) suture anchor with horizontal mattress configuration, (3) double-loaded suture anchor with simple stitch configuration, or (4) KSA. Data recorded included mode of failure, ultimate load to failure, load at 2 mm of displacement, as well as displacement during cyclical loading. For phase 1, the load required to 2 mm displacement of the repair construct was significantly greater in SSA (66.5 +/- 21.7 N) than KSA (35.0 +/- 12.5 N, P = .02). For phase 2, there was a statistically significant difference in ultimate load to failure among the 4groups, with both the single-loaded suture anchor with simple stitch (184.0 +/- 64.5 N), horizontal mattress stitch (189.0 +/- 65.3N), and double-loaded suture anchor with simple stitch (216.7 +/- 61.7 N) groups having significantly (P .05) among the 4 groups in displacement after cyclical loading or load at 2 mm of displacement. Both knotless and simple anchor configurations demonstrated similar single loads to failure (without cycling); however, the knotless device required less single load to displace 2 mm. All repair stitches, including simple, horizontal, and double-loaded performed similarly. The findings may suggest that with cyclical loading up to 25 N there is no difference in gapping greater than 2mm, but a macrotraumatic event may demonstrate a difference in fixation during the initial

  15. A reusable suture anchor for arthroscopy psychomotor skills training.

    Science.gov (United States)

    Tillett, Edward D; Rogers, Rainie; Nyland, John

    2003-03-01

    For residents to adequately develop the early arthroscopy psychomotor skills required to better learn how to manage the improvisational situations they will encounter during actual patient cases, they need to experience sufficient practice repetitions within a contextually relevant environment. Unfortunately, the cost of suture anchors can be a practice repetition-limiting factor in learning arthroscopic knot-tying techniques. We describe a technique for creating inexpensive reusable suture anchors and provide an example of their application to repair the anterior glenoid labrum during an arthroscopy psychomotor skills laboratory training session.

  16. Primary closure of equine laryngotomy incisions

    DEFF Research Database (Denmark)

    Lindegaard, C.; Karlsson, L.; Ekstrøm, Claus Thorn

    2016-01-01

    The objective was to report healing characteristics and complications after primary closure of equine laryngotomies and analyse factors potentially associated with complications. This retrospective case series of the medical records of horses (n = 180) undergoing laryngoplasty and laryngotomy...... after primary closure of equine laryngotomy incisions are infrequent and considered of minimal severity and can be performed safely when paying careful attention to the closure of the cricothyroid membrane....

  17. Ocular Biometry in Angle Closure

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2013-01-01

    Full Text Available Purpose: To compare ocular biometric parameters in primary angle closure suspects (PACS, primary angle closure glaucoma (PACG and acute primary angle closure (APAC. Methods: This cross-sectional study was performed on 113 patients including 33 cases of PACS, 45 patients with PACG and 35 subjects with APAC. Central corneal thickness (CCT, axial length (AL, anterior chamber depth (ACD and lens thickness (LT were measured with an ultrasonic biometer. Lens-axial length factor (LAF, relative lens position, corrected ACD (CACD and corrected lens position were calculated. The parameters were measured bilaterally but only data from the right eyes were compared. In the APAC group, biometric parameters were also compared between affected and unaffected fellow eyes. Logistic regression analysis was performed to identify risk factors. Results: No statistically significant difference was observed in biometric parameters between PACS and PACG eyes, or between affected and fellow eyes in the APAC group (P>0.05 for all comparisons. However, eyes with APAC had thicker cornea (P=0.001, thicker lens (P<0.0001, shallower ACD (P=0.009, shallower CACD (P=0.003 and larger LAF (P<0.0001. Based on ROC curve analysis, lower ACD, and larger LT, LAF and CCT values were associated with APAC. In the APAC group, LAF (P<0.0001 and CCT (P=0.001 were significant risk factors. Conclusion: This study revealed no significant difference in biometric characteristics in eyes with PACS and PACG. However, larger LAF and CCT were predictive of APAC.

  18. Sustained eye closure slows saccades

    Science.gov (United States)

    Shaikh, Aasef G.; Wong, Aaron L.; Optican, Lance M.; Miura, Kenichiro; Solomon, David; Zee, David S.

    2010-01-01

    Saccadic eye movements rapidly orient the line of sight towards the object of interest. Pre-motor burst neurons (BNs) controlling saccades receive excitation from superior colliculus and cerebellum, but inhibition by omnipause neurons (OPNs) prevents saccades. When the OPNs pause, BNs begin to fire. It has been presumed that part of the BN burst comes from post-inhibitory rebound (PIR). We hypothesized that in the absence of prior inhibition from OPNs there would be no PIR, and thus the increase in initial firing rate of BNs would be reduced. Consequently, saccade acceleration would be reduced. We measured eye movements and showed that sustained eye closure, which inhibits the activity of OPNs and thus hypothetically should weaken PIR, reduced the peak velocity, acceleration, and deceleration of saccades in healthy human subjects. Saccades under closed eyelids also had irregular trajectories; the frequency of the oscillations underlying this irregularity was similar to that of high-frequency ocular flutter (back-to-back saccades) often seen in normal subjects during attempted fixation at straight ahead while eyes are closed. Saccades and quick phases of nystagmus are generated by the same pre-motor neurons, and we found that the quick-phase velocity of nystagmus was also reduced by lid closure. These changes were not due to a mechanical hindrance to the eyes, because lid closure did not affect the peak velocities or accelerations of the eyes in the “slow-phase” response to rapid head movements of comparable speeds to those of saccades. These results indicate a role for OPNs in generating the abrupt onset and high velocities of saccades. We hypothesize that the mechanism involved is PIR in pre-motor burst neurons. PMID:20573593