  1. Cavitation

    CERN Document Server

    Young, F Ronald

    1999-01-01

    First published by McGraw-Hill in 1989, this book provides a unified treatment of cavitation, a phenomenon which extends across the boundaries of many fields. The approach is wide-ranging and the aim is to give due consideration to the many aspects of cavitation in proportion to their importance. Particular attention is paid to the diverse situations in which cavitation occurs and to its practical applications.

  2. Characterization of periodic cavitation in an optical tweezer

    CERN Document Server

    Carmona-Sosa, Viridiana; Quinto-Su, Pedro A

    2015-01-01

    Microscopic vapor explosions or cavitation bubbles can be generated periodically in an optical tweezer with a microparticle that partially absorbs at the trapping laser wavelength. In this work we correlate the size of the cavitation bubbles with the cycle frequency for microparticles with a diameter of 3 $\\mu$m. We use high speed video recording to measure the maximum bubble sizes and a fast photodiode to collect the trapping laser light scattered by both the particle and the transient bubble. We find an inverse relation between maximum bubble size and cycle frequency, consistent with a longer displacement of the microbead induced by larger bubbles and hence a longer time back to the waist. More than $94 \\%$ of the measured maximum bubble radiuses are in the range between 2 and 6 $\\mu$m, while the same percentage of the measured frequencies are between 10 and 200 Hz. The width of the scattered light signal for both particle and bubble during cavitation is proportional to the predicted lifetime for a spherica...

  3. Cavitation bubble oscillation period as a process diagnostic during the laser shock peening process

    CSIR Research Space (South Africa)

    Glaser, Daniel

    2017-09-01

    Full Text Available the pressure pulse delivered to the target. For thick water layers, or fully water immersed LSP, a cavitation bubble is generated by the surface vaporization of the LSP laser pulse. This research shows that the first bubble oscillation period of the cavitation...

  4. Sustained release formulations of citronella oil nanoemulsion using cavitational techniques.

    Science.gov (United States)

    Agrawal, Naveen; Maddikeri, Ganesh L; Pandit, Aniruddha B

    2017-05-01

    Nanoemulsion synthesis has proven to be an effective way for transportation of immobile, insoluble bioactive compounds. Citronella Oil (lemongrass oil), a natural plant extract, can be used as a mosquito repellent and has less harmful effects compared to its available market counterpart DEET (N, N-Diethyl-meta-toluamide). Nanoemulsion of citronella oil in water was prepared using cavitation-assisted techniques while investigating the effect of system parameters like HLB (Hydrophilic Lipophilic Balance), surfactant concentration, input energy density and mode of power input on emulsion quality. The present work also examines the effect of emulsification on release rate to understand the relationship between droplet size and the release rate. Minimum droplet size (60nm) of the emulsion was obtained at HLB of 14, S/O1 ratio of 1.0, ultrasound amplitude of 50% and irradiation time of 5min. This study revealed that hydrodynamic cavitation-assisted emulsification is more energy efficient compared to ultrasonic emulsification. It was also found that the release rate of nanoemulsion enhanced as the droplet size of emulsion reduced. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Cavitation bubble oscillation period as a process diagnostic during the laser shock peening process

    Science.gov (United States)

    Glaser, D.; Polese, C.

    2017-09-01

    Laser shock peening (LSP) technology is a laser-induced shock process implemented as a surface enhancement technique to introduce beneficial compressive residual stresses into metallic components. The process employs water to confine and enhance the pressure pulse delivered to the target. For thick water layers, or fully water immersed LSP, a cavitation bubble is generated by the surface vaporization of the LSP laser pulse. This research shows that the first bubble oscillation period of the cavitation bubble can be used to characterize effective and repeatable energy delivery to the target. High-speed shadowgraphy is implemented to show that variations in the bubble period occur before visual observations of dielectric breakdown in water. The diagnostic potential of the first bubble oscillation period is used to identify the dielectric breakdown threshold of water, which shows an increase with increasing water quality measured by water conductivity.

  6. An analysis of the acoustic cavitation noise spectrum: The role of periodic shock waves.

    Science.gov (United States)

    Song, Jae Hee; Johansen, Kristoffer; Prentice, Paul

    2016-10-01

    Research on applications of acoustic cavitation is often reported in terms of the features within the spectrum of the emissions gathered during cavitation occurrence. There is, however, limited understanding as to the contribution of specific bubble activity to spectral features, beyond a binary interpretation of stable versus inertial cavitation. In this work, laser-nucleation is used to initiate cavitation within a few millimeters of the tip of a needle hydrophone, calibrated for magnitude and phase from 125 kHz to 20 MHz. The bubble activity, acoustically driven at f0 = 692 kHz, is resolved with high-speed shadowgraphic imaging at 5 × 10(6) frames per second. A synthetic spectrum is constructed from component signals based on the hydrophone data, deconvolved within the calibration bandwidth, in the time domain. Cross correlation coefficients between the experimental and synthetic spectra of 0.97 for the f0/2 and f0/3 regimes indicate that periodic shock waves and scattered driving field predominantly account for all spectral features, including the sub-harmonics and their over-harmonics, and harmonics of f0.

  7. Auditory sustained field responses to periodic noise

    Directory of Open Access Journals (Sweden)

    Keceli Sumru

    2012-01-01

    Full Text Available Abstract Background Auditory sustained responses have been recently suggested to reflect neural processing of speech sounds in the auditory cortex. As periodic fluctuations below the pitch range are important for speech perception, it is necessary to investigate how low frequency periodic sounds are processed in the human auditory cortex. Auditory sustained responses have been shown to be sensitive to temporal regularity but the relationship between the amplitudes of auditory evoked sustained responses and the repetitive rates of auditory inputs remains elusive. As the temporal and spectral features of sounds enhance different components of sustained responses, previous studies with click trains and vowel stimuli presented diverging results. In order to investigate the effect of repetition rate on cortical responses, we analyzed the auditory sustained fields evoked by periodic and aperiodic noises using magnetoencephalography. Results Sustained fields were elicited by white noise and repeating frozen noise stimuli with repetition rates of 5-, 10-, 50-, 200- and 500 Hz. The sustained field amplitudes were significantly larger for all the periodic stimuli than for white noise. Although the sustained field amplitudes showed a rising and falling pattern within the repetition rate range, the response amplitudes to 5 Hz repetition rate were significantly larger than to 500 Hz. Conclusions The enhanced sustained field responses to periodic noises show that cortical sensitivity to periodic sounds is maintained for a wide range of repetition rates. Persistence of periodicity sensitivity below the pitch range suggests that in addition to processing the fundamental frequency of voice, sustained field generators can also resolve low frequency temporal modulations in speech envelope.

  8. Time-resolved monitoring of cavitation activity in megasonic cleaning systems.

    Science.gov (United States)

    Hauptmann, M; Brems, S; Struyf, H; Mertens, P; Heyns, M; De Gendt, S; Glorieux, C

    2012-03-01

    The occurrence of acoustic cavitation in the cleaning liquid is a crucial precondition for the performance of megasonic cleaning systems. Hence, a fundamental understanding of the impact of different parameters of the megasonic process on cavitation activity is necessary. A setup capable of synchronously measuring sonoluminescence and acoustic emission originating from acoustically active bubbles is presented. The system also includes a high-speed-stroboscopic Schlieren imaging system to directly visualize the influence of cavitation activity on the Schlieren contrast and resolvable bubbles. This allows a thorough characterization of the mutual interaction of cavitation bubbles with the sound field and with each other. Results obtained during continuous sonication of argon-saturated water at various nominal power densities indicate that acoustic cavitation occurs in a cyclic manner, during which periods of stable and inertial cavitation activity alternate. The occurrence of higher and ultraharmonics in the acoustic emission spectra is characteristic for the stable cavitation state. The inertial cavitation state is characterized by a strong attenuation of the sound field, the explosive growth of bubbles and the occurrence of broadband components in the acoustic spectra. Both states can only be sustained at sufficiently high intensities of the sound field. At lower intensities, their occurrences are limited to short, random bursts. Cleaning activity can be linked to the cavitation activity through the measurement of particle removal on standard 200 mm silicon wafers. It is found that the particle removal efficiency is reduced, when a continuous state of cavitation activity ceases to exist.

  9. Rotating Cavitation Supression Project

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a rotating cavitation (RC) suppressor for liquid rocket engine turbopump inducers. Cavitation instabilities, such as rotating cavitation,...

  10. Xenon plasma sustained by pulse-periodic laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Rudoy, I. G.; Solovyov, N. G.; Soroka, A. M.; Shilov, A. O.; Yakimov, M. Yu., E-mail: yakimov@lantanlaser.ru [Russian Academy of Sciences, A. Ishlinsky Institute for Problems in Mechanics (Russian Federation)

    2015-10-15

    The possibility of sustaining a quasi-stationary pulse-periodic optical discharge (POD) in xenon at a pressure of p = 10–20 bar in a focused 1.07-μm Yb{sup 3+} laser beam with a pulse repetition rate of f{sub rep} ⩾ 2 kHz, pulse duration of τ ⩾ 200 μs, and power of P = 200–300 W has been demonstrated. In the plasma development phase, the POD pulse brightness is generally several times higher than the stationary brightness of a continuous optical discharge at the same laser power, which indicates a higher plasma temperature in the POD regime. Upon termination of the laser pulse, plasma recombines and is then reinitiated in the next pulse. The initial absorption of laser radiation in successive POD pulses is provided by 5p{sup 5}6s excited states of xenon atoms. This kind of discharge can be applied in plasma-based high-brightness broadband light sources.

  11. Microbubble Cavitation Imaging

    Science.gov (United States)

    Vignon, Francois; Shi, William T.; Powers, Jeffry E.; Everbach, E. Carr; Liu, Jinjin; Gao, Shunji; Xie, Feng; Porter, Thomas R.

    2014-01-01

    Ultrasound cavitation of microbubble contrast agents has a potential for therapeutic applications such as sonothrombolysis (STL) in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (moderate oscillations, stable cavitation, and inertial cavitation) and activity level in and around a treatment area. Acoustic passive cavitation detectors (PCDs) have been used to this end but do not provide spatial information. This paper presents a prototype of a 2-D cavitation imager capable of producing images of the dominant cavitation state and activity level in a region of interest. Similar to PCDs, the cavitation imaging described here is based on the spectral analysis of the acoustic signal radiated by the cavitating microbubbles: ultraharmonics of the excitation frequency indicate stable cavitation, whereas elevated noise bands indicate inertial cavitation; the absence of both indicates moderate oscillations. The prototype system is a modified commercially available ultrasound scanner with a sector imaging probe. The lateral resolution of the system is 1.5 mm at a focal depth of 3 cm, and the axial resolution is 3 cm for a therapy pulse length of 20 µs. The maximum frame rate of the prototype is 2 Hz. The system has been used for assessing and mapping the relative importance of the different cavitation states of a microbubble contrast agent. In vitro (tissue-mimicking flow phantom) and in vivo (heart, liver, and brain of two swine) results for cavitation states and their changes as a function of acoustic amplitude are presented. PMID:23549527

  12. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    Science.gov (United States)

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Cavitation wear of pump impellers

    Directory of Open Access Journals (Sweden)

    Mirosław Szala

    2016-12-01

    Full Text Available Cavitation is a common phenomenon in pump systems, negatively influencing their operating parameters and components such as impellers and, thus, causing considerable financial losses. This paper explains the problem of cavitation and cavitation erosion. The causes of cavitation in pump systems are analyzed. A selection of centrifugal pump impellers damaged by cavitation erosion are presented and examined. The authors also discuss ways of preventing cavitation and cavitation erosion in pump systems. Finally, relevant conclusions are drawn.

  14. Sustainable Mobility, Future Fuels, and the Periodic Table

    Science.gov (United States)

    Wallington, Timothy J.; Anderson, James E.; Siegel, Donald J.; Tamor, Michael A.; Mueller, Sherry A.; Winkler, Sandra L.; Nielsen, Ole J.

    2013-01-01

    Providing sustainable mobility is a major challenge that will require new vehicle and fuel technologies. Alternative and future fuels are the subject of considerable research and public interest. A simple approach is presented that can be used in science education lectures at the high school or undergraduate level to provide students with an…

  15. FOREWORD: International Symposium of Cavitation and Multiphase Flow (ISCM 2014)

    Science.gov (United States)

    Wu, Yulin

    2015-01-01

    multiphase flow detection Fluid-structure interaction induced by cavitation and multiphase flow Multi-scale modelling of cavitating flows and Multiphase Flow Cavitation nuclei: theory and experiments Supercavitation and its applications Synergetic effects of cavitation and silt-laden erosion Shock waves and microjets generated by cavitation Nonlinear oscillations of gas and vapour bubbles Fundamentals of physics of acoustic cavitation Sonochemistry and sonoluminescence Biomedical applications of cavitation effects Ultrasonic cavitation for molten metal treatment Cavitation for enhanced heat transfer The ISCM 2014 brought together 95 scientists, researchers and graduate students from 11 countries, affiliated with universities, technology centers and industrial firms to debate topics related to advanced technologies for cavitation and Multiphase Flow, which would enhance the sustainable development of cavitation and Multiphase Flow in interdisciplinary sciences and technology. The technical committee selected 54 technical papers on the following topics: (i) Hydrodynamic Cavitation, (ii) Super Cavitation, (iii) Pump Cavitation, (iv) Acoustic Cavitation, (v) Interdisciplinary Research of Cavitation and Multi-Phase Flows, and 13 invited plenary and invited forum lectures, which were presented at the symposium, to be included in the proceedings. All the papers of ISCM 2014, which are published in this Volume of IOP Conference Series: Materials Science and Engineering, had been peer reviewed through processes administered by the editors of the ISCM 2014, those are Yulin WU, Shouqi YUAN, Zhengwei WANG, Shuhong LIU, Xingqi LUO, Fujun WANG and Guoyu WANG. The papers published in this Volume include 54 technical papers and 3 full length texts of the invited lectures. We sincerely hope that the International Symposium on Cavitation and Multiphase Flow is a significant step forward in the world wide efforts to address the present challenges in the modern science and technology. Professor

  16. Dynamics of Vortex Cavitation

    NARCIS (Netherlands)

    Pennings, P.C.

    2016-01-01

    This thesis describes the mechanisms with which tip vortex cavitation is responsible for broadband pressure fluctuations on ship propellers. Hypotheses for these are described in detail by Bosschers (2009). Validation is provided by three main cavitation-tunnel experiments, one on a model propeller

  17. Can Cavitation Be Anticipated?

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, G.O.; Dress, W.B.; Hylton, J.O.; Kercel, S.W.

    1999-04-25

    The major problem with cavitation in pumps and hydraulic systems is that there is no effective (conventional) method for detecting or predicting its inception. The traditional method of recognizing cavitation in a pump is to declare the event occurring when the total head drops by some arbitrary value (typically 3%) in response to a pressure reduction at the pump inlet. However, the device is already seriously cavitating when this happens. What is actually needed is a practical method to detect impending rather than incipient cavitation. Whereas the detection of incipient cavitation requires the detection of features just after cavitation starts, the anticipation of cavitation requires the detection and identification of precursor features just before it begins. Two recent advances that make this detection possible. The first is acoustic sensors with a bandwidth of 1 MHz and a dynamic range of 80 dB that preserve the fine details of the features when subjected to coarse vibrations. The second is the application of Bayesian parameter estimation which makes it possible to separate weak signals, such as those present in cavitation precursors, from strong signals, such as pump vibration. Bayesian parameter estimation derives a model based on cavitation hydrodynamics and produces a figure of merit of how well it fits the acquired data. Applying this model to an anticipatory engine should lead to a reliable method of anticipating cavitation before it occurs. This paper reports the findings of precursor features using high-performance sensors and Bayesian analysis of weak acoustic emissions in the 100-1000kHz band from an experimental flow loop.

  18. Dental pulp reaction to Cavit temporary filling material.

    Science.gov (United States)

    Provant, D R; Adrian, J C

    1978-02-01

    Seventy-two teeth in three Macaque fasicularis monkeys were used to evaluate pulpal response to cavit. Displacement of odontoblastic nuclei was evaluated histologically at three time periods in order to identify initial, early, and final responses. There were no statistically significant differences in pulpal response between Cavit and the zinc oxide-eugenol controls when used in accordance with the manufacturer's directions.

  19. Cavitation in flowing superfluid helium

    Science.gov (United States)

    Daney, D. E.

    1988-01-01

    Flowing superfluid helium cavitates much more readily than normal liquid helium, and there is a marked difference in the cavitation behavior of the two fluids as the lambda point is traversed. Examples of cavitation in a turbine meter and centrifugal pump are given, together with measurements of the cavitation strength of flowing superfluid helium. The unusual cavitation behavior of superfluid helium is attributed to its immense thermal conductivity .

  20. Fundamentals of Cavitation

    CERN Document Server

    Franc, Jean-Pierre

    2005-01-01

    The present book is aimed at providing a comprehensive presentation of cavitation phenomena in liquid flows. It is further backed up by the experience, both experimental and theoretical, of the authors whose expertise has been internationally recognized. A special effort is made to place the various methods of investigation in strong relation with the fundamental physics of cavitation, enabling the reader to treat specific problems independently. Furthermore, it is hoped that a better knowledge of the cavitation phenomenon will allow engineers to create systems using it positively. Examples in the literature show the feasibility of this approach.

  1. Cavitation During Superplastic Forming

    Directory of Open Access Journals (Sweden)

    John Campbell

    2011-07-01

    Full Text Available Cavitation is the opening of pores during superplastic forming, typically at grain boundary triple points or on second phase grain boundary particles during slip of grain boundaries. Theories for the initiation of cavitation are reviewed. It seems that cavitation is unlikely to occur by processes intrinsic to metals such as dislocation mechanisms or point defect condensation. It is proposed that cavitation can only occur at non-bonded interfaces such as those introduced extrinsically (i.e., from the outside during the original casting of the metal. These defects, known as oxide bifilms, are naturally introduced during pouring of the liquid metal, and are frozen into the solid, often pushed by dendritic growth into grain boundaries where they are difficult to detect because of their extreme thinness, often measured in nanometres. Their unbonded central interface acts as a crack and can initiate cavitation. Second phase precipitates probably do not nucleate and grow on grain boundaries but grow on bifilms in the boundaries, explaining the apparent association between boundaries, second phase particles and failure initiation. Improved melting and casting techniques can provide metal with reduced or zero bifilm population for which cavitation would not be possible, promising significant improvements in superplastic behaviour.

  2. Cavitation During Superplastic Forming.

    Science.gov (United States)

    Campbell, John

    2011-07-08

    Cavitation is the opening of pores during superplastic forming, typically at grain boundary triple points or on second phase grain boundary particles during slip of grain boundaries. Theories for the initiation of cavitation are reviewed. It seems that cavitation is unlikely to occur by processes intrinsic to metals such as dislocation mechanisms or point defect condensation. It is proposed that cavitation can only occur at non-bonded interfaces such as those introduced extrinsically (i.e., from the outside) during the original casting of the metal. These defects, known as oxide bifilms, are naturally introduced during pouring of the liquid metal, and are frozen into the solid, often pushed by dendritic growth into grain boundaries where they are difficult to detect because of their extreme thinness, often measured in nanometres. Their unbonded central interface acts as a crack and can initiate cavitation. Second phase precipitates probably do not nucleate and grow on grain boundaries but grow on bifilms in the boundaries, explaining the apparent association between boundaries, second phase particles and failure initiation. Improved melting and casting techniques can provide metal with reduced or zero bifilm population for which cavitation would not be possible, promising significant improvements in superplastic behaviour.

  3. On cavitation instabilities with interacting voids

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    2012-01-01

    When a single void grows in an elastic–plastic material a cavitation instability may occur, if the stress triaxiality is sufficiently high. The effect of neighbouring voids on such unstable cavity growth is studied here by comparing two different models. The first model considers a periodic array...... voids so far apart that the radius of the plastic zone around each void is less than 1% of the current spacing between the voids, can still affect each others at the occurrence of a cavitation instability such that one void stops growing while the other grows in an unstable manner. On the other hand...

  4. Cavitation in medicine.

    Science.gov (United States)

    Brennen, Christopher Earls

    2015-10-06

    We generally think of bubbles as benign and harmless and yet they can manifest the most remarkable range of physical effects. Some of those effects are the stuff of our everyday experience as in the tinkling of a brook or the sounds of breaking waves at the beach. But even these mundane effects are examples of the ability of bubbles to gather, focus and radiate energy (acoustic energy in the above examples). In other contexts that focusing of energy can lead to serious technological problems as when cavitation bubbles eat great holes through ships' propeller blades or cause a threat to the integrity of the spillways at the Hoover Dam. In liquid-propelled rocket engines, bubbles pose a danger to the stability of the propulsion system, and in artificial heart valves they can cause serious damage to the red blood cells. In perhaps the most extraordinary example of energy focusing, collapsing cavitation bubbles can emit not only sound, but also light with black body radiation temperatures equal to that of the sun (Brennen 1995 Cavitation and bubble dynamics). But, harnessed carefully, this almost unique ability to focus energy can also be put to remarkably constructive use. Cavitation bubbles are now used in a remarkable range of surgical and medical procedures, for example to emulsify tissue (most commonly in cataract surgery or in lithotripsy procedures for the reduction of kidney and gall stones) or to manipulate the DNA in individual cells. By creating cavitation bubbles non-invasively thereby depositing and focusing energy non-intrusively, one can generate minute incisions or target cancer cells. This paper will begin by briefly reviewing the history of cavitation phenomena and will end with a vision of the new horizons for the amazing cavitation bubble.

  5. Pressure Propagation of Impinging Jet with Cavitation by Numerical Analysis

    Science.gov (United States)

    Kanamori, Daisei; Inoue, Fumihiro; Ohta, Yutaka

    2017-10-01

    In recent years, cavitating jet has attracted attention as an application of water jet technology. In its application, it is important to clarify the jet flow structure and the behavior of bubble cloud collapse. Therefore, in order to visualize the cavitating jet flow structure and elucidate the behavior of collapsing of cavitation bubble clouds, we conducted numerical simulations with gas-liquid two-phase media model. We validated the numerical model by comparing the numerical results with the theoretical and experimental results and had a good agreement. In the case of gas-liquid two-phase free jet, cavitation bubble clouds emit periodically and transfer at a regular speed. And some bubble clouds merge with a preceding bubble clouds. Comparing with liquid single-phase jet, the core region is maintained to the further downstream and we show the usefulness of the cavitating jet. In the case of gas-liquid two-phase impinging jet, after a cavitation bubble cloud collides with wall, it is broken by applying pressure and generates a shock wave. At this time, the impact pressure becomes maximum. Thereafter, the shock wave affects other cavitation bubble clouds and break these. The collapsed cavitation bubble cloud rebounds and collapses again near the collision wall surface.

  6. Detecting Cavitation Pitting Without Disassembly

    Science.gov (United States)

    Barkhoudarian, S.

    1986-01-01

    Technique for detecting cavitation pitting in pumps, turbines, and other machinery uses low-level nuclear irradiation. Isotopes concentrated below surface emit gamma radiation, a portion of which is attenuated by overlying material. Where there are cavitation pits, output of gamma-ray detector fluctuates as detector is scanned near pits. Important to detect cavitation pits because nozzle, turbine blade, or other pump component weakened by cavitation could fail catastrophically and cause machine to explode.

  7. Sustainability of a Compartmentalized Host-Parasite Replicator System under Periodic Washout-Mixing Cycles

    Directory of Open Access Journals (Sweden)

    Taro Furubayashi

    2018-01-01

    Full Text Available The emergence and dominance of parasitic replicators are among the major hurdles for the proliferation of primitive replicators. Compartmentalization of replicators is proposed to relieve the parasite dominance; however, it remains unclear under what conditions simple compartmentalization uncoupled with internal reaction secures the long-term survival of a population of primitive replicators against incessant parasite emergence. Here, we investigate the sustainability of a compartmentalized host-parasite replicator (CHPR system undergoing periodic washout-mixing cycles, by constructing a mathematical model and performing extensive simulations. We describe sustainable landscapes of the CHPR system in the parameter space and elucidate the mechanism of phase transitions between sustainable and extinct regions. Our findings revealed that a large population size of compartments, a high mixing intensity, and a modest amount of nutrients are important factors for the robust survival of replicators. We also found two distinctive sustainable phases with different mixing intensities. These results suggest that a population of simple host–parasite replicators assumed before the origin of life can be sustained by a simple compartmentalization with periodic washout-mixing processes.

  8. Cavitations induced by plasmas, plasmas induced by cavitations, and plasmas produced in cavitations

    Science.gov (United States)

    Sasaki, Koichi

    2015-11-01

    Cavitation bubbles are not static bubbles but have dynamics of expansion, shrinkage, and collapse. Since the collapse of a cavitation bubble is roughly an adiabatic process, the inside of the bubble at the collapse has a high temperature and a high pressure, resulting in the production of a plasma. This talk will be focused on cavitation-related plasma phenomena and the role of the cavitation bubble in the synthesis of nanoparticles. A method for inducing a cavitation bubble is laser ablation in liquid. After the disappearance of laser-produced plasma with optical emission, we have observed the formation of a cavitation bubble. We have found that the inside of the cavitation bubble is the reaction field for the synthesis of nanoparticles. The atomic and molecular species ejected from the ablation target toward the liquid are transported into the cavitation bubble, and they condense into nanoparticles inside it. It is important to note that nanoparticles are stored inside the cavitation bubble until its collapse. We have shown that the size and the structure of nanoparticles are controlled by controlling the dynamics of the cavitation bubbles. Another method for inducing cavitation bubbles is to use ultrasonic power. We have found a simple method for the efficient production of standing cavitation bubbles. The method is just inserting a punching metal plate into water irradiated by ultrasonic wave. The depth of water and the position of the punching plate should be tuned precisely. We have proposed the mechanism of the efficient production of cavitation bubbles by this method. Currently, we try to have electric discharges in cavitation bubbles with the intention of realizing nonequilibrium sonochemistry. In particular, the electric discharge in a laser-induced cavitation bubble shows interesting distortion of the bubble shape, which suggests the electrostatic characteristics of the cavitation bubble.

  9. Taming Acoustic Cavitation

    CERN Document Server

    Rivas, David Fernandez; Enriquez, Oscar R; Versluis, Michel; Prosperetti, Andrea; Gardeniers, Han; Lohse, Detlef

    2012-01-01

    In this fluid dynamics video we show acoustic cavitation occurring from pits etched on a silicon surface. By immersing the surface in a liquid, gas pockets are entrapped in the pits which upon ultrasonic insonation, are observed to shed cavitation bubbles. Modulating the driving pressure it is possible to induce different behaviours based on the force balance that determines the interaction among bubbles and the silicon surface. This system can be used for several applications like sonochemical water treatment, cleaning of surfaces with deposited materials such as biofilms.

  10. Cavitation in liquid helium

    Energy Technology Data Exchange (ETDEWEB)

    Finch, R. D.; Kagiwada, R.; Barmatz, M.; Rudnick, I.

    1963-11-15

    Ultrasonic cavitation was induced in liquid helium over the temperature range 1.2 to 2.3 deg K, using a pair of identical transducers. The transducers were calibrated using a reciprocity technique and the cavitation threshold was determined at 90 kc/s. It was found that this threshold has a sharp peak at the lambda point, but is, at all temperatures quite low, with an approximate range of 0.001 to 0.01 atm. The significance of the results is discussed. (auth)

  11. Cavitation bubble dynamics.

    Science.gov (United States)

    Lauterborn, W; Ohl, C D

    1997-04-01

    The dynamics of cavitation bubbles on water is investigated for bubbles produced optically and acoustically. Single bubble dynamics is studied with laser produced bubbles and high speed photography with framing rates up to 20.8 million frames per second. Examples for jet formation and shock wave emission are given. Acoustic cavitation is produced in water in the interior of piezoelectric cylinders of different sizes (up to 12 cm inner diameter). The filementary structure composed of bubbles is investigated and their light emission (sonoluminescence) studied for various driving strengths.

  12. Cavitation simulation on marine propellers

    DEFF Research Database (Denmark)

    Shin, Keun Woo

    Cavitation on marine propellers causes thrust breakdown, noise, vibration and erosion. The increasing demand for high-efficiency propellers makes it difficult to avoid the occurrence of cavitation. Currently, practical analysis of propeller cavitation depends on cavitation tunnel test, empirical...... criteria and inviscid flow method, but a series of model test is costly and the other two methods have low accuracy. Nowadays, computational fluid dynamics by using a viscous flow solver is common for practical industrial applications in many disciplines. Cavitation models in viscous flow solvers have been...... developed in the last decade. They show the potential for the simulation of propeller cavitation with robustness, but they are still to be more proved for practical applications. In the present work, hydrodynamic and numerical characteristics of several cavitation models developed for a viscous flow solver...

  13. Transient cavitation in pipelines

    NARCIS (Netherlands)

    Kranenburg, C.

    1974-01-01

    The aim of the present study is to set up a one-dimensional mathematical model, which describes the transient flow in pipelines, taking into account the influence of cavitation and free gas. The flow will be conceived of as a three-phase flow of the liquid, its vapour and non-condensible gas. The

  14. Dynamics of cavitation-structure interaction

    Science.gov (United States)

    Wang, Guoyu; Wu, Qin; Huang, Biao

    2017-08-01

    Cavitation-structure interaction has become one of the major issues for most engineering applications. The present work reviews recent progress made toward developing experimental and numerical investigation for unsteady turbulent cavitating flow and cavitation-structure interaction. The goal of our overall efforts is to (1) summarize the progress made in the experimental and numerical modeling and approaches for unsteady cavitating flow and cavitation-structure interaction, (2) discuss the global multiphase structures for different cavitation regimes, with special emphasis on the unsteady development of cloud cavitation and corresponding cavitating flow-induced vibrations, with a high-speed visualization system and a structural vibration measurement system, as well as a simultaneous sampling system, (3) improve the understanding of the hydroelastic response in cavitating flows via combined physical and numerical analysis, with particular emphasis on the interaction between unsteady cavitation development and structural deformations. Issues including unsteady cavitating flow structures and cavitation-structure interaction mechanism are discussed.

  15. Comparing environmental issues in Cuba before and after the Special Period: balancing sustainable development and survival.

    Science.gov (United States)

    Maal-Bared, Rasha

    2006-04-01

    Following the Earth Summit in 1992, Cuba designed and implemented a variety of programs, administrative structures, and public awareness activities to promote sound environmental management and sustainable development. This came shortly after the fall of the Soviet Union and the strengthening of the US blockade in 1990, which resulted in a 35% drop in Cuban GDP. This period, referred to as the Special Period, witnessed a decrease in many environmentally damaging activities both by choice and by necessity, but also resulted in many decisions to resuscitate the Cuban economy. The purpose of this work was to compare and rank the environmental risks Cuba faced before and during the Special Period (1990-2000) using two Comparative environmental risk assessments (CERAs). To do so, an ecosystem integrity risk assessment matrix was constructed with 42 risk end points. The matrix assessed the risk posed by 17 problem areas including air pollution, water contamination, solid waste sites, pesticides and ecosystem degradation. The risks were calculated using five criteria: area affected, vulnerability of affected population, severity of impact, irreversibility of effect and uncertainty. To construct this matrix, both literature reviews and expert interviews in Cuba were conducted in 2000. The results showed a general decrease in risk scores during the Special Period. Before the Special Period, high risks were posed by: terrestrial degradation and industrial wastewater and sludge, followed by freshwater degradation, surface water stressors, and pesticides. After the Special Period, industrial wastewater and sludge and pesticides were no longer high-risk areas, but municipal wastewater and marine coastal degradation ranked higher than previously. Also, the risk endpoints most stressed after 1990 were affected by activities controlled by the government, such as mining and tourism, and lack of infrastructure. Therefore, the claims that public environmental education is the main

  16. Techniques of Ultrasound Cavitation Control

    Directory of Open Access Journals (Sweden)

    S. P. Skvortsov

    2015-01-01

    Full Text Available The control methods of ultrasonic cavitation applied now within the range from 20 kHz to 80 kHz use either control of ultrasound source parameters (amplitude, acoustic power, etc. or control of one of the cavitation effects (erosion of materials, sonoluminescence, power of acoustic noise, etc.. These methods provide effective management of technological processes, however, make it impossible to relate the estimated effect with parameters of pulsations of cavitation bubbles. This is, mainly, due to influence of a number of uncontrollable parameters, in particular, such as temperature, composition of liquid, gas content, etc. as well as because of the difficulty to establish interrelation between the estimated effect and parameters of pulsations. As a result, in most cases it is difficult to compare controlled parameters of ultrasonic cavitation among themselves, and quantitative characteristics of processes become depending on the type of ultrasonic installation and conditions of their measurement.In this regard, methods to determine parameters of bubble pulsations through sounding a cavitation area by low-intensity laser radiation or to record cavitation noise sub-harmonics reflecting dynamics of changing radius of cavitation bubbles are of interest. The method of optical sounding, via the analysis of spectral components of a scattered signal recorded by a photo-detector, allows us to define a phase of the bubbles collapse with respect to the sound wave and a moving speed of the bubbles wall, as well as to estimate a cavitation index within the light beam section.The method to record sub-harmonicas of cavitation noise allows us to define parameters of pulsations, average for cavitation areas.The above methods allow us both to study mechanisms of cavitation action and to form quantitative criteria of its efficiency based on the physical processes, rather than their consequences and are convenient for arranging a feedback in the units using

  17. 76 FR 55954 - Astralis Ltd., Cavit Sciences, Inc., Crystal International Travel Group, Inc., and Tasker...

    Science.gov (United States)

    2011-09-09

    ... From the Federal Register Online via the Government Publishing Office SECURITIES AND EXCHANGE COMMISSION Astralis Ltd., Cavit Sciences, Inc., Crystal International Travel Group, Inc., and Tasker Products... securities of Cavit Sciences, Inc. because it has not filed any periodic reports since the period ended...

  18. Controlling cavitation-based image contrast in focused ultrasound histotripsy surgery.

    Science.gov (United States)

    Allen, Steven P; Hall, Timothy L; Cain, Charles A; Hernandez-Garcia, Luis

    2015-01-01

    To develop MRI feedback for cavitation-based, focused ultrasound, tissue erosion surgery (histotripsy), we investigate image contrast generated by transient cavitation events. Changes in GRE image intensity are observed while balanced pairs of field gradients are varied in the presence of an acoustically driven cavitation event. The amplitude of the acoustic pulse and the timing between a cavitation event and the start of these gradient waveforms are also varied. The magnitudes and phases of the cavitation site are compared with those of control images. An echo-planar sequence is used to evaluate histotripsy lesions in ex vivo tissue. Cavitation events in water cause localized attenuation when acoustic pulses exceed a pressure threshold. Attenuation increases with increasing gradient amplitude and gradient lobe separation times and is isotropic with gradient direction. This attenuation also depends upon the relative timing between the cavitation event and the start of the balanced gradients. These factors can be used to control the appearance of attenuation while imaging ex vivo tissue. By controlling the timing between cavitation events and the imaging gradients, MR images can be made alternately sensitive or insensitive to cavitation. During therapy, these images can be used to isolate contrast generated by cavitation. © 2014 Wiley Periodicals, Inc.

  19. Cavitation onset caused by acceleration.

    Science.gov (United States)

    Pan, Zhao; Kiyama, Akihito; Tagawa, Yoshiyuki; Daily, David J; Thomson, Scott L; Hurd, Randy; Truscott, Tadd T

    2017-07-24

    Striking the top of a liquid-filled bottle can shatter the bottom. An intuitive interpretation of this event might label an impulsive force as the culprit in this fracturing phenomenon. However, high-speed photography reveals the formation and collapse of tiny bubbles near the bottom before fracture. This observation indicates that the damaging phenomenon of cavitation is at fault. Cavitation is well known for causing damage in various applications including pipes and ship propellers, making accurate prediction of cavitation onset vital in several industries. However, the conventional cavitation number as a function of velocity incorrectly predicts the cavitation onset caused by acceleration. This unexplained discrepancy leads to the derivation of an alternative dimensionless term from the equation of motion, predicting cavitation as a function of acceleration and fluid depth rather than velocity. Two independent research groups in different countries have tested this theory; separate series of experiments confirm that an alternative cavitation number, presented in this paper, defines the universal criteria for the onset of acceleration-induced cavitation.

  20. Cavitation onset caused by acceleration

    Science.gov (United States)

    Pan, Zhao; Kiyama, Akihito; Tagawa, Yoshiyuki; Daily, David J.; Thomson, Scott L.; Hurd, Randy; Truscott, Tadd T.

    2017-08-01

    Striking the top of a liquid-filled bottle can shatter the bottom. An intuitive interpretation of this event might label an impulsive force as the culprit in this fracturing phenomenon. However, high-speed photography reveals the formation and collapse of tiny bubbles near the bottom before fracture. This observation indicates that the damaging phenomenon of cavitation is at fault. Cavitation is well known for causing damage in various applications including pipes and ship propellers, making accurate prediction of cavitation onset vital in several industries. However, the conventional cavitation number as a function of velocity incorrectly predicts the cavitation onset caused by acceleration. This unexplained discrepancy leads to the derivation of an alternative dimensionless term from the equation of motion, predicting cavitation as a function of acceleration and fluid depth rather than velocity. Two independent research groups in different countries have tested this theory; separate series of experiments confirm that an alternative cavitation number, presented in this paper, defines the universal criteria for the onset of acceleration-induced cavitation.

  1. Cavitation Nuclei: Experiments and Theory

    DEFF Research Database (Denmark)

    Mørch, Knud Aage

    2009-01-01

    us a chance to reflect on the character of the unknown parameters. In this way non-concordant experimental results may hold the key to the development of better theories - and to new experiments for the testing of their validity. Cavitation and cavitation nuclei are phenomena of that character....

  2. Sustainable Irrigation Allocation Model for Dry and Wet Periods using Reservoir Storage and Inflow

    Science.gov (United States)

    Surianarayanan, S.; Suribabu, C. R.; Ramakrishnan, K.

    2017-07-01

    The dry period agriculture is inevitable both for the farmers for their earning, and for the soil for its fertility by crop-rotation. In tropical countries like INDIA, dry period agriculture becomes difficult because of less (or) no rain fall. Hence a simple water balancing model for irrigation scheduling, using the measure “Volumetric Reliability” is prepared in this paper, with the storage and inflow of a reservoir both for the dry and wet periods. The case-study is done for a reservoir in INDIA with thirty one years of hydrological data(from 1982 to 2012). The objective of this paper is to prepare a simple water balance model taking 10 days periods of demand and supply for ID crop(Irrigated Dry crop, ground nut) with usage of volumetric reliability concept for the periods of deficiency and adoption of less water requirement crops to reduce the water-stress during critical periods of crop growth, and finally arrive at a feasible allocation schedule for the success of agriculture and the yield throughout the year both for wet and dry crops with the available storage on the start of irrigation for a particular year. The reservoir is divided for storages such as full, deficient and critical storages. The starting storage for the dry period from January is used after adequate allocation for wet crops, the quantity for riparian rights and for drinking water, for the sustainability. By the water-balancing, the time-series for thirty one years, it is found that for twenty two years the demand for the ID crops is satisfied with the storage in the reservoir, and in the remaining years of deficient inflows, for three years (1986,1996,2004)the demand is managed by using the safe reliability factor for demand which can nullify the deficit in demand for the whole supply period. But it is genuine to assure that the reduction in the amount of water for each 10 days periods should not exceed the survival limit of the crop. Necessary soil-moisture must be ensured in the crop

  3. Cavitation-resistant inducer

    Science.gov (United States)

    Dunn, Charlton; Subbaraman, Maria R.

    1989-01-01

    An improvement in an inducer for a pump wherein the inducer includes a hub, a plurality of radially extending substantially helical blades and a wall member extending about and encompassing an outer periphery of the blades. The improvement comprises forming adjacent pairs of blades and the hub to provide a substantially rectangular cross-sectional flow area which cross-sectional flow area decreases from the inlet end of the inducer to a discharge end of the inducer, resulting in increased inducer efficiency improved suction performance, reduced susceptibility to cavitation, reduced susceptibility to hub separation and reduced fabrication costs.

  4. Cavitation effects in ultrasonic cleaning baths

    Science.gov (United States)

    Glasscock, Barbara H.

    1995-01-01

    In this project, the effect of cavitation from aqueous ultrasonic cleaning on the surfaces of metal and non-metal sample coupons was studied. After twenty cleaning cycles, the mass loss from the aluminum coupons averaged 0.22 mg/sq cm surface area and 0.014 mg/sq cm for both stainless steel and titanium. The aluminum coupons showed visual evidence of minor cavitation erosion in regions of previously existing surface irregularities. The non-metal samples showed some periods of mass gain. These effects are believed to have minor impact on hardware being cleaned, but should be evaluated in the context of specific hardware requirements. Also the ultrasonic activity in the large cleaning baths was found to be unevenly distributed as measured by damage to sheets of aluminum foil. It is therefore recommended that items being cleaned in an ultrasonic bath be moved or conveyed during the cleaning to more evenly distribute the cavitation action provide more uniform cleaning.

  5. Size effects on cavitation instabilities

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Tvergaard, Viggo

    2006-01-01

    In metal-ceramic systems the constraint on plastic flow leads to so high stress triaxialities that cavitation instabilities may occur. If the void radius is on the order of magnitude of a characteristic length for the metal, the rate of void growth is reduced, and the possibility of unstable cavity...... triaxiality, where cavitation instabilities are predicted by conventional plasticity theory, such instabilities are also found for the nonlocal theory, but the effects of gradient hardening delay the onset of the instability. Furthermore, in some cases the cavitation stress reaches a maximum and then decays...

  6. Microleakage of Cavit, CavitW, CavitG and IRM by impedance spectroscopy.

    Science.gov (United States)

    Jacquot, B M; Panighi, M M; Steinmetz, P; G'Sell, C

    1996-07-01

    The aim of this study was to quantify the sealing ability of four temporary filling materials over 9 days using a new electrochemical technique. Fifty-two extracted human maxillary bicuspids were selected and prepared for the measurements. They were divided into four groups of 12 teeth each, in addition to two positive and two negative controls. After preparation of the endodontic access cavity the sealing ability was registered. After a randomization procedure one group was obturated with IRM, another group with Cavit, a third group with CavitW and the last group with CavitG. The sealability was measured just after obturation (time 0) and after days 1, 2, 3, 4, 7 and 9. The results showed that the IRM group was significantly more watertight than the different Cavit formulations. Throughout the experiment no significant difference was noticed between the Cavit and CavitW groups (P > 0.05). The CavitG group was significantly less watertight throughout the measurements (P < 0.05).

  7. Cavitation inception from bubble nuclei

    DEFF Research Database (Denmark)

    Mørch, Knud Aage

    2015-01-01

    . The cavitation nuclei may be free gas bubbles in the bulk of water, or interfacial gaseous voids located on the surface of particles in the water, or on bounding walls. The tensile strength of these nuclei depends not only on the water quality but also on the pressure-time history of the water. A recent model......The tensile strength of ordinary water such as tap water or seawater is typically well below 1 bar. It is governed by cavitation nuclei in the water, not by the tensile strength of the water itself, which is extremely high. Different models of the nuclei have been suggested over the years......, and experimental investigations of bubbles and cavitation inception have been presented. These results suggest that cavitation nuclei in equilibrium are gaseous voids in the water, stabilized by a skin which allows diffusion balance between gas inside the void and gas in solution in the surrounding liquid...

  8. Fracture of elastomers by cavitation

    KAUST Repository

    Hamdi, Adel

    2014-01-01

    Cavitation phenomenon is studied in rubber-like materials by combining experimental, theoretical and numerical approaches. Specific tests are carried out on a Styrene Butadiene Rubber to point out main characteristics of cavitation phenomenon. Hydrostatic depression is numerically modelled using finite element method. Numerical results are compared to Ball\\'s and Hou & Abeyaratne\\'s models with regard to cavity nucleation in the material. Both models well fit experimental observations suggesting that the cavitation nucleation in elastomers depends on the confinement degree of the specimen. Finally, critical hydrostatic pressure and critical global deformation are proved to govern cavitation nucleation in the studied material. Critical loadings are identified by comparing experimental and numerical load-displacement curves. © 2013 Elsevier Ltd.

  9. Current research in cavitating fluid films

    Science.gov (United States)

    Brewe, D. E. (Editor); Ball, J. H. (Editor); Khonsari, M. M. (Editor)

    1990-01-01

    A review of the current research of cavitation in fluid films is presented. Phenomena and experimental observations include gaseous cavitation, vapor cavitation, and gas entrainment. Cavitation in flooded, starved, and dynamically loaded journal bearings, as well as squeeze films are reviewed. Observations of cavitation damage in bearings and the possibility of cavitation between parallel plates with microasperities were discussed. The transcavity fluid transport process, meniscus motion and geometry or form of the film during rupture, and reformation were summarized. Performance effects were related to heat transfer models in the cavitated region and hysteresis influence on rotor dynamics coefficients. A number of cavitation algorithms was presented together with solution procedures using the finite difference and finite element methods. Although Newtonian fluids were assumed in most of the discussions, the effect of non-Newtonian fluids on cavitation was also discussed.

  10. Some Cavitation Properties of Liquids

    Directory of Open Access Journals (Sweden)

    K. D. Efremova

    2016-01-01

    Full Text Available Cavitation properties of liquid must be taken into consideration in the engineering design of hydraulic machines and hydro devices when there is a possibility that in their operation an absolute pressure in the liquid drops below atmospheric one, and for a certain time the liquid is in depression state. Cold boiling, which occurs at a comparatively low temperature under a reduced absolute pressure within or on the surface of the liquid is regarded as hydrostatic cavitation if the liquid is stationary or as hydrodynamic cavitation, if the liquid falls into conditions when in the flow cross-section there is a sharply increasing dynamic pressure and a dropping absolute pressure.In accordance with the theory of cavitation, the first phase of cavitation occurs when the absolute pressure of the degassed liquid drops to the saturated vapour pressure, and the air dissolved in the liquid, leaving the intermolecular space, is converted into micro-bubbles of combined air and becomes a generator of cavitation “nuclei”. A quantitative estimate of the minimum allowable absolute pressure in a real, fully or partially degassed liquid at which a hydrostatic cavitation occurs is of practical interest.Since the pressure of saturated vapour of a liquid is, to a certain extent, related to the forces of intermolecular interaction, it is necessary to have information on the cavitation properties of technical solutions, including air solution in a liquid, as a solute may weaken intermolecular bonds and affect the pressure value of the saturated solvent vapour. In the experiment to carry out vacuum degassing of liquids was used a hydraulic air driven vacuum pump.The paper presents hydrostatic and hydrodynamic degassing liquid processes used in the experiment.The experimental studies of the cavitation properties of technical liquids (sea and distilled water, saturated NaCl solution, and pure glycerol and as a 49/51% solution in water, mineral oil and jet fuel enabled

  11. Doppler velocimetry in cavitating media.

    Science.gov (United States)

    Pindera, M Z; Siegel, J M; Makhijani, V B

    1997-01-01

    A numerical model has been developed to simulate propagation of ultrasonic beams in inhomogeneous moving media. The model is based on the ray theory of propagating waves, valid in the limit of high frequencies. The resulting equations depend only on local values of the velocity field and the speed of sound. In its implementation, the model assumes that the interactions of sound with the surrounding flow field are decoupled. This allows for applying the model in a post processing mode to flows computed by other means. The model was used to investigate beam behavior in unsteady cavitating flows. The study was motivated by reports of cavitation occurring in mitral bi-leaflet mechanical heart valves. The flow field and cavitation physics were simulated using a general purpose computer code, CFD-ACE. The ultrasonic beam model was then used to calculate the beam path, orientation, and frequency changes in the transient cavitating region. Results show that the presence of cavitation can fundamentally alter the beam propagation characteristics. Simple models that assume rectilinear propagation cannot, by definition, handle such flows. Cavitation incurs very large variations in the local sound speed, which in turn can induce very large distortions in the beam. This fact has strong ramifications regarding the accuracy of ultrasonic velocimetry when simple models are used to interpret Doppler data gathered under such flow conditions.

  12. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for

  13. Cavitation instabilities between fibres in a metal matrix composite

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    2016-01-01

    induced by bonding to the ceramics that only show elastic deformation. In an MMC the stress state in the metal matrix is highly non-uniform, varying between regions where shear stresses are dominant and regions where hydrostatic tension is strong. An Al–SiC whisker composite with a periodic pattern......Short fibre reinforced metal matrix composites (MMC) are studied here to investigate the possibility that a cavitation instability can develop in the metal matrix. The high stress levels needed for a cavitation instability may occur in metal–ceramic systems due to the constraint on plastic flow...

  14. Effect of temperature change on the sealing properties of Cavit and Cavit G.

    Science.gov (United States)

    Oppenheimer, S; Rosenberg, P A

    1979-09-01

    Sixty recently extracted intact anterior teeth were filled with Cavit G or Cavit. They were examined for dye penetration at room temperature and subjected to temperature change. Under the test conditions Cavit G and Cavit were resistant to penetration by aqueous methylene blue dye.

  15. Sonoluminescence and acoustic cavitation

    Science.gov (United States)

    Choi, Pak-Kon

    2017-07-01

    Sonoluminescence (SL) is light emission under high-temperature and high-pressure conditions of a cavitating bubble under intense ultrasound in liquid. In this review, the fundamentals of the interactions between the sound field and the bubble, and between bubbles are explained. Experimental results on high-speed shadowgraphy of bubble dynamics and multibubble SL are shown, demonstrating that the SL intensity is closely related to the bubble dynamics. SL studies of alkali-metal atom (Na and K) emission are summarized. The spectral measurements in solutions with different noble-gas dissolutions and in surfactant solutions, and the results of spatiotemporal separation of SL distribution strongly suggested that the site of alkali-metal atom emission is the gas phase inside bubbles. The spectral studies indicated that alkali-metal atom lines are composed of two kinds of lines: a component that is broadened and shifted from the original D lines arises from van der Waals molecules formed between alkali-metal atoms and noble-gas atoms under extreme conditions at bubble collapse. The other spectral component exhibiting no broadening and no shift was suggested to originate from higher temperature bubbles than those producing the broadened component.

  16. Effects of fishing during the spawning period: implications for sustainable management

    NARCIS (Netherlands)

    Overzee, van H.M.J.; Rijnsdorp, A.D.

    2015-01-01

    While fishery closures during the spawning season are commonplace, direct evidence for their benefit is mainly restricted to species forming large spawning aggregations. This paper analyses the conditions under which spawning closures could contribute to sustainable fisheries management by reviewing

  17. Cavitation erosion size scale effects

    Science.gov (United States)

    Rao, P. V.; Buckley, D. H.

    1984-01-01

    Size scaling in cavitation erosion is a major problem confronting the design engineers of modern high speed machinery. An overview and erosion data analysis presented in this paper indicate that the size scale exponent n in the erosion rate relationship as a function of the size or diameter can vary from 1.7 to 4.9 depending on the type of device used. There is, however, a general agreement as to the values of n if the correlations are made with constant cavitation number.

  18. Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit.

    Science.gov (United States)

    Izadifar, Zahra; Belev, George; Babyn, Paul; Chapman, Dean

    2015-10-19

    The observation of ultrasound generated cavitation bubbles deep in tissue is very difficult. The development of an imaging method capable of investigating cavitation bubbles in tissue would improve the efficiency and application of ultrasound in the clinic. Among the previous imaging modalities capable of detecting cavitation bubbles in vivo, the acoustic detection technique has the positive aspect of in vivo application. However the size of the initial cavitation bubble and the amplitude of the ultrasound that produced the cavitation bubbles, affect the timing and amplitude of the cavitation bubbles' emissions. The spatial distribution of cavitation bubbles, driven by 0.8835 MHz therapeutic ultrasound system at output power of 14 Watt, was studied in water using a synchrotron X-ray imaging technique, Analyzer Based Imaging (ABI). The cavitation bubble distribution was investigated by repeated application of the ultrasound and imaging the water tank. The spatial frequency of the cavitation bubble pattern was evaluated by Fourier analysis. Acoustic cavitation was imaged at four different locations through the acoustic beam in water at a fixed power level. The pattern of cavitation bubbles in water was detected by synchrotron X-ray ABI. The spatial distribution of cavitation bubbles driven by the therapeutic ultrasound system was observed using ABI X-ray imaging technique. It was observed that the cavitation bubbles appeared in a periodic pattern. The calculated distance between intervals revealed that the distance of frequent cavitation lines (intervals) is one-half of the acoustic wave length consistent with standing waves. This set of experiments demonstrates the utility of synchrotron ABI for visualizing cavitation bubbles formed in water by clinical ultrasound systems working at high frequency and output powers as low as a therapeutic system.

  19. Reflections on cavitation nuclei in water

    DEFF Research Database (Denmark)

    Mørch, Knud Aage

    2007-01-01

    The origin of cavitation bubbles, cavitation nuclei, has been a subject of debate since the early years of cavitation research. This paper presents an analysis of a representative selection of experimental investigations of cavitation inception and the tensile strength of water. At atmospheric...... pressure, the possibility of stabilization of free gas bubbles by a skin has been documented, but only within a range of bubble sizes that makes them responsible for tensile strengths up to about 1.5 bar, and values reaching almost 300 bar have been measured. However, cavitation nuclei can also be harbored...

  20. A review of China’s approaches toward a sustainable energy future: the period since 1990

    DEFF Research Database (Denmark)

    Zhu, Xianli; Zhuang, Guiyang; Xiong, Na

    2014-01-01

    energy future. It then uses eight indicators to assess China’s progress in improving the sustainability of its energy system. This article finally discusses some aspects that could be improved and the new directions and initiatives China is taking to tackle new issues in its energy development. © 2013...... to meet the widening gap between domestic demand and supply, and reducing environmental pollution and greenhouse gas emissions. Identifying China’s approaches toward ensuring a sustainable energy future in the last two decades and assessing their effectiveness can be of great value to the future of energy......, affordable and reliable energy supplies, and the evolution of China’s strategies for energy development since 1990. On the basis of an empirical review of the different policies and measures taken by the government over time, it explains China’s approach to achieving the different aspects of a sustainable...

  1. Cavitation instabilities and rotordynamic effects in turbopumps and hydroturbines turbopump and inducer cavitation, experiments and design

    CERN Document Server

    Salvetti, Maria

    2017-01-01

    The book provides a detailed approach to the physics, fluid dynamics, modeling, experimentation and numerical simulation of cavitation phenomena, with special emphasis on cavitation-induced instabilities and their implications on the design and operation of high performance turbopumps and hydraulic turbines. The first part covers the fundamentals (nucleation, dynamics, thermodynamic effects, erosion) and forms of cavitation (attached cavitation, cloud cavitation, supercavitation, vortex cavitation) relevant to hydraulic turbomachinery, illustrates modern experimental techniques for the characterization, visualization and analysis of cavitating flows, and introduces the main aspects of the hydrodynamic design and performance of axial inducers, centrifugal turbopumps and hydo-turbines. The second part focuses on the theoretical modeling, experimental analysis, and practical control of cavitation-induced fluid-dynamic and rotordynamic instabilities of hydraulic turbomachinery, with special emphasis on cavitating...

  2. Generation and control of acoustic cavitation structure.

    Science.gov (United States)

    Bai, Lixin; Xu, Weilin; Deng, Jingjun; Li, Chao; Xu, Delong; Gao, Yandong

    2014-09-01

    The generation and control of acoustic cavitation structure are a prerequisite for application of cavitation in the field of ultrasonic sonochemistry and ultrasonic cleaning. The generation and control of several typical acoustic cavitation structures (conical bubble structure, smoker, acoustic Lichtenberg figure, tailing bubble structure, jet-induced bubble structures) in a 20-50 kHz ultrasonic field are investigated. Cavitation bubbles tend to move along the direction of pressure drop in the region in front of radiating surface, which are the premise and the foundation of some strong acoustic cavitation structure formation. The nuclei source of above-mentioned acoustic cavitation structures is analyzed. The relationship and mutual transformation of these acoustic cavitation structures are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Cavitation pulse extraction and centrifugal pump analysis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Hong Lind Shaoran [University of Electronic Science and Technology of China, Chengdu (China); Yu, Bo; Qing, Biao [Xihua University, Chengdu (China)

    2017-03-15

    This study extracted cavitation pulses from hydrophone signals sampled in a centrifugal pump and analyzed their characteristics. The modified and simplified Empirical mode decomposition (EMD) algorithm was proposed for extracting cavitation pulses from strong background noise. Experimental results showed that EMD can effectively suppress noise and obtain clear cavitation pulses, facilitating the identification of the number of pulses associated with the degree of cavitation. The cavitation characteristics were modeled to predict the value of incipient cavitation. Then, we proposed a method for detecting the wear of the impeller surface. That is, the information on the impeller surface of the centrifugal pump, including the roughness of the impeller surface and its wear trends, were quantified based on the net positive suction head available of incipient cavitation. The findings indicate that the proposed technique is suitable for condition monitoring of the pump.

  4. Faktor-Faktor yang Mempengaruhi Financial Sustainability Ratio pada Bank Umum Swast Nasional Non Devisa Periode 1995-2005

    Directory of Open Access Journals (Sweden)

    Luciana Spica Almilia

    2009-01-01

    Full Text Available This study is aimed to test the consistency of time period model, whether the information that previously affects today’s performance can be used to predict the performance in the future, and how the consistency of Indonesia banking financial prediction model formulation equation in order to detect bank condition and performance in the period of pre-economic crisis (1995-1996, during economic crisis (1997-1999 or post-economic crisis (2000-2005 is since bank condition and health is the interest of all relevant parties namely bank owner and manager, customers, Bank Indonesia in its capacity as the supervisor and builder, and the government. The samples are Non Foreign Exchange National Private Banks listed in Indonesian Banking Directory during the period after economic crisis in 1995 – 2005 and Indonesian Financial Economic Statistics Monthly Statement for economic macro indicator. The sampling is performed by means of purposive method (purposive sampling. Dependent Variable in this study is Financial Sustainability Ratio and independent variable in this study is Capital Adequacy Ratio, Non Performing Loan, Return On Assets, Operational Cost Ratio to Operational Income, Loan to Deposit Ratio, Money Supply Sensitivity, General Customer Price Index Sensitivity and SBI Interest Rate Sensitivity. The result of this study shows that model financial sustainability ratio did not have structural stabilization in 1999 – 2005. Abstract in Bahasa Indonesia: Penelitian ini betujuan untuk menguji konsistensi model prediksi kinerja keuangan pada Bank Umum Swasta Nasional Non Devisa periode 1995-2005. Variabel-variabel yang digunakan dalam penelitian ini adalah kinerja keuangan Bank Umum Swasta Nasional Non Devisa yang diproksikan melalui Financial Sustainability Ratio (FSR. Sampel yang terpilih dalam penelitian ini dengan metode purposive sampling berjumlah 28 bank umum swasta nasional non devisa yang terdaftar di direktori Bank Indonesia selama tahun

  5. Inertial cavitation initiated by polytetrafluoroethylene nanoparticles under pulsed ultrasound stimulation.

    Science.gov (United States)

    Jin, Qiaofeng; Kang, Shih-Tsung; Chang, Yuan-Chih; Zheng, Hairong; Yeh, Chih-Kuang

    2016-09-01

    Nanoscale gas bubbles residing on a macroscale hydrophobic surface have a surprising long lifetime (on the order of days) and can serve as cavitation nuclei for initiating inertial cavitation (IC). Whether interfacial nanobubbles (NBs) reside on the infinite surface of a hydrophobic nanoparticle (NP) and could serve as cavitation nuclei is unknown, but this would be very meaningful for the development of sonosensitive NPs. To address this problem, we investigated the IC activity of polytetrafluoroethylene (PTFE) NPs, which are regarded as benchmark superhydrophobic NPs due to their low surface energy caused by the presence of fluorocarbon. Both a passive cavitation detection system and terephthalic dosimetry was applied to quantify the intensity of IC. The IC intensities of the suspension with PTFE NPs were 10.30 and 48.41 times stronger than those of deionized water for peak negative pressures of 2 and 5MPa, respectively. However, the IC activities were nearly completely inhibited when the suspension was degassed or ethanol was used to suspend PTFE NPs, and they were recovered when suspended in saturated water, which may indicates the presence of interfacial NBs on PTFE NPs surfaces. Importantly, these PTFE NPs could sustainably initiate IC for excitation by a sequence of at least 6000 pulses, whereas lipid microbubbles were completely depleted after the application of no more than 50 pulses under the same conditions. The terephthalic dosimetry has shown that much higher hydroxyl yields were achieved when PTFE NPs were present as cavitation nuclei when using ultrasound parameters that otherwise did not produce significant amounts of free radicals. These results show that superhydrophobic NPs may be an outstanding candidate for use in IC-related applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. In Vivo Microbubble Cavitation Imaging

    NARCIS (Netherlands)

    Vignon, F.; Shi, W.; Liu, J.; Xie, F.; Gao, S.; Drvol, L.; Lof, J.; Everbach, C.; Porter, T.; Powers, J.

    2011-01-01

    Stroke is the second cause of death and leading cause of disabilityworldwide. Less than 5% of ischemic stroke patients receive the state-of-the art treatment of a thrombolytic drug tPA, and only about 10% of these gain additional benefit from it. Ultrasound (US)-inducedmicrobubble (MB) cavitation

  7. Cavitation inception from bubble nuclei

    Science.gov (United States)

    Mørch, K. A.

    2015-01-01

    The tensile strength of ordinary water such as tap water or seawater is typically well below 1 bar. It is governed by cavitation nuclei in the water, not by the tensile strength of the water itself, which is extremely high. Different models of the nuclei have been suggested over the years, and experimental investigations of bubbles and cavitation inception have been presented. These results suggest that cavitation nuclei in equilibrium are gaseous voids in the water, stabilized by a skin which allows diffusion balance between gas inside the void and gas in solution in the surrounding liquid. The cavitation nuclei may be free gas bubbles in the bulk of water, or interfacial gaseous voids located on the surface of particles in the water, or on bounding walls. The tensile strength of these nuclei depends not only on the water quality but also on the pressure–time history of the water. A recent model and associated experiments throw new light on the effects of transient pressures on the tensile strength of water, which may be notably reduced or increased by such pressure changes. PMID:26442138

  8. Sonoporation from jetting cavitation bubbles

    NARCIS (Netherlands)

    Ohl, C.D.; Arora, M.; Ikink, Roy; de Jong, N.; Versluis, Michel; Delius, Michael; Lohse, Detlef

    2006-01-01

    The fluid dynamic interaction of cavitation bubbles with adherent cells on a substrate is experimentally investigated. We find that the nonspherical collapse of bubbles near to the boundary is responsible for cell detachment. High-speed photography reveals that a wall bounded flow leads to the

  9. Sonoporation from jetting cavitation bubbles

    NARCIS (Netherlands)

    C.-D. Ohl (Claus-Dieter); M. Arora (Manish); R. Ikink (Roy); N. de Jong (Nico); M. Versluis (Michel); M. Delius (Michael); D. Lohse (Detlef)

    2006-01-01

    textabstractThe fluid dynamic interaction of cavitation bubbles with adherent cells on a substrate is experimentally investigated. We find that the nonspherical collapse of bubbles near to the boundary is responsible for cell detachment. High-speed photography reveals that a wall bounded flow leads

  10. Numerical Investigation Cavitation Buckets for Hydrofoil Parametrically

    Directory of Open Access Journals (Sweden)

    Mehmet Salih KARAALİOĞLU

    2015-12-01

    Full Text Available Cavitation is a general fluid mechanics phenomenon that is appeared in system such as pumps, turbines, marine propellers and hydrofoils which induces pressure and velocity fluctuation in the fluid (Brennen, 2013. Cavitation can be defined as the formation of vapour regions due to a decrease in local pressure. Undesirable consequences which can cause a fall in the performance of a system, structural failure, production of noise and vibration, material damage, are encountered due to cavitation (Uşar, 2015. In this study, cavitation was analysed using a bucket diagram. Bucket diagram represents the cavitation behaviour of a wing, fin or propeller blade in a two dimensional sense. This diagram is plotted as a function of section (hydrofoil angle of attack (α versus section cavitation number (σ. Pressure distribution can be calculated on two dimensional geometry of hydrofoil by using BEM (Boundary Element Method and cavitation bucket diagram can be computed. The cavitation inception case and partial cavitation cases have been investigated and the results of the present BEM were successfully compared with those of given in literature in the past and each other. While a constant source-dipole panel method has been used to calculate the pressure distribution at cavitation inception case, PCPAN programme that solves the sheet type of cavity on the hydrofoil by potential based panel method, has been used to calculate pressure distribution for the cases of partial cavitation. Effects of maximum hydrofoil thickness, maximum camber and location of maximum camber on cavitation have been analyzed by means of cavitation bucklet diagrams. All results are discussed in a detailed manner.

  11. Controlled effect of ultrasonic cavitation on hydrophobic/hydrophilic surfaces.

    Science.gov (United States)

    Belova, Valentina; Gorin, Dmitry A; Shchukin, Dmitry G; Möhwald, Helmuth

    2011-02-01

    Controlling cavitation at the solid surface is of increasing interest, as it plays a major role in many physical and chemical processes related to the modification of solid surfaces and formation of multicomponent nanoparticles. Here, we show a selective control of ultrasonic cavitation on metal surfaces with different hydrophobicity. By applying a microcontact printing technique we successfully formed hydrophobic/hydrophilic alternating well-defined microstructures on aluminium surfaces. Fabrication of patterned surfaces provides the unique opportunity to verify a model of heterogeneous nucleation of cavitation bubbles near the solid/water interface by varying the wettability of the surface, temperature and ultrasonic power. At the initial stage of sonication (up to 30 min), microjets and shock waves resulting from the collapsing bubbles preferably impact the hydrophobic surface, whereas the hydrophilic areas of the patterned Al remain unchanged. Longer sonication periods affect both surfaces. These findings confirm the expectation that higher contact angle causes a lower energy barrier, thus cavitation dominates at the hydrophobic surfaces. Experimental results are in good agreement with expectations from nucleation theory. This paper illustrates a new approach to ultrasound induced modification of solid surfaces resulting in the formation of foam-structured metal surfaces.

  12. Processing of Microalgae: Acoustic Cavitation and Hydrothermal Conversion

    Science.gov (United States)

    Greenly, Justin Michael

    The production of energy dense fuels from renewable algal biomass feedstocks -- if sustainably developed at a sufficiently large scale -- may reduce the consumption of petroleum from fossil fuels and provide many environmental benefits. Achieving economic feasibility has several technical engineering challenges that arise from dilute concentration of growing algae in aqueous media, small cell sizes, and durable cell walls. For microalgae to be a sustainable source of biofuels and co-products, efficient fractionation and conversion of the cellular contents is necessary. Research was carried out to address two processing options for efficient microalgae biofuel production: 1. Ultrasonic cavitation for cell disruption and 2. Hydrothermal conversion of a model algal triglyceride. 1. Ultrasonic cell disruption, which relies on cavitating bubbles in the suspension to produce damaging shock waves, was investigated experimentally over a range of concentrations and species types. A few seconds of high intensity sonication at fixed frequency yielded significant cell disruption, even for the more durable cells. At longer exposure times, effectiveness was seen to decline and was attributed, using acoustic measurements, to ultrasonic power attenuation in the ensuing cloud of cavitating bubbles. Processing at higher cell concentrations slowed cell disintegration marginally, but increased the effectiveness of dissipating ultrasonic energy. A theoretical study effectively predicted optimal conditions for a variety of parameters that were inaccessible in this experimental investigation. In that study, single bubble collapse was modeled to identify operating conditions that would increase cavitation, and thus cell disruption. Simulations were conducted by varying frequency and pressure amplitude of the ultrasound wave, and initial bubble size. The simulation results indicated that low frequency, high sound wave amplitudes, and small initial bubble size generate the highest shock

  13. Cavitation nucleation in gelatin: Experiment and mechanism.

    Science.gov (United States)

    Kang, Wonmo; Adnan, Ashfaq; O'Shaughnessy, Thomas; Bagchi, Amit

    2018-02-01

    Dynamic cavitation in soft materials is becoming increasingly relevant due to emerging medical implications such as the potential of cavitation-induced brain injury or cavitation created by therapeutic medical devices. However, the current understanding of dynamic cavitation in soft materials is still very limited, mainly due to lack of robust experimental techniques. To experimentally characterize cavitation nucleation under dynamic loading, we utilize a recently developed experimental instrument, the integrated drop tower system. This technique allows quantitative measurements of the critical acceleration (a cr ) that corresponds to cavitation nucleation while concurrently visualizing time evolution of cavitation. Our experimental results reveal that a cr increases with increasing concentration of gelatin in pure water. Interestingly, we have observed the distinctive transition from a sharp increase (pure water to 1% gelatin) to a much slower rate of increase (∼10× slower) between 1% and 7.5% gelatin. Theoretical cavitation criterion predicts the general trend of increasing a cr , but fails to explain the transition rates. As a likely mechanism, we consider concentration-dependent material properties and non-spherical cavitation nucleation sites, represented by pre-existing bubbles in gels, due to possible interplay between gelatin molecules and nucleation sites. This analysis shows that cavitation nucleation is very sensitive to the initial configuration of a bubble, i.e., a non-spherical bubble can significantly increase a cr . This conclusion matches well with the experimentally observed liquid-to-gel transition in the critical acceleration for cavitation nucleation. From a medical standpoint, understanding dynamic cavitation within soft materials, i.e., tissues, is important as there are both potential injury implications (blast-induced cavitation within the brain) as well as treatments utilizing the phenomena (lithotripsy). In this regard, the main

  14. Determination of Acoustic Cavitation Probabilities and Thresholds Using a Single Focusing Transducer to Induce and Detect Acoustic Cavitation Events: I. Method and Terminology.

    Science.gov (United States)

    Haller, Julian; Wilkens, Volker; Shaw, Adam

    2018-02-01

    A method to determine acoustic cavitation probabilities in tissue-mimicking materials (TMMs) is described that uses a high-intensity focused ultrasound (HIFU) transducer for both inducing and detecting the acoustic cavitation events. The method was evaluated by studying acoustic cavitation probabilities in agar-based TMMs with and without scatterers and for different sonication modes like continuous wave, single pulses (microseconds to milliseconds) and repeated burst signals. Acoustic cavitation thresholds (defined here as the peak rarefactional in situ pressure at which the acoustic cavitation probability reaches 50%) at a frequency of 1.06 MHz were observed between 1.1 MPa (for 1 s of continuous wave sonication) and 4.6 MPa (for 1 s of a repeated burst signal with 25-cycle burst length and 10-ms burst period) in a 3% (by weight) agar phantom without scatterers. The method and its evaluation are described, and general terminology useful for standardizing the description of insonation conditions and comparing results is provided. In the accompanying second part, the presented method is used to systematically study the acoustic cavitation thresholds in the same material for a range of sonication modes. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Relations between acoustic cavitation and skin resistance during intermediate- and high-frequency sonophoresis.

    Science.gov (United States)

    Rich, Kyle T; Hoerig, Cameron L; Rao, Marepalli B; Mast, T Douglas

    2014-11-28

    Enhanced skin permeability is known to be achieved during sonophoresis due to ultrasound-induced cavitation. However, the mechanistic role of cavitation during sonophoresis has been extensively investigated only for low-frequency (LFS, cavitation were investigated by passively monitoring subharmonic and broadband emissions arising from cavitation isolated within or external to porcine skin in vitro during intermediate- (IFS, 100-700 kHz) and high-frequency sonophoresis (HFS, >1 MHz). The electrical resistance of skin, a surrogate measure of the permeability of skin to a variety of compounds, was measured to quantify the reduction and subsequent recovery of the skin barrier during and after exposure to pulsed (1 second pulse, 20% duty cycle) 0.41 and 2.0 MHz ultrasound over a range of acoustic powers (0-21.7 W) for 30 min. During IFS, significant skin resistance reductions and acoustic emissions from cavitation were measured exclusively when cavitation was isolated outside of the skin. Time-dependent skin resistance reductions measured during IFS correlated significantly with subharmonic and broadband emission levels. During HFS, significant skin resistance reductions were accompanied by significant acoustic emissions from cavitation measured during trials that isolated cavitation activity either outside of skin or within skin. Time-dependent skin resistance reductions measured during HFS correlated significantly greater with subharmonic than with broadband emission levels. The reduction of the skin barrier due to sonophoresis was reversible in all trials; however, effects incurred during IFS recovered more slowly and persisted over a longer period of time than HFS. These results quantitatively demonstrate the significance of cavitation during sonophoresis and suggest that the mechanisms and post-treatment longevity of permeability enhancement due to IFS and HFS treatments are different. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The influence of surface roughness on cloud cavitation flow around hydrofoils

    Science.gov (United States)

    Hao, Jiafeng; Zhang, Mindi; Huang, Xu

    2017-08-01

    The aim of this study is to investigate experimentally the effect of surface roughness on cloud cavitation around Clark-Y hydrofoils. High-speed video and particle image velocimetry (PIV) were used to obtain cavitation patterns images (Prog. Aerosp. Sci. 37: 551-581, 2001), as well as velocity and vorticity fields. Results are presented for cloud cavitating conditions around a Clark-Y hydrofoil fixed at angle of attack of α =8{°} for moderate Reynolds number of Re=5.6 × 105 . The results show that roughness had a great influence on the pattern, velocity and vorticity distribution of cloud cavitation. For cavitating flow around a smooth hydrofoil (A) and a rough hydrofoil (B), cloud cavitation occurred in the form of finger-like cavities and attached subulate cavities, respectively. The period of cloud cavitation around hydrofoil A was shorter than for hydrofoil B. Surface roughness had a great influence on the process of cloud cavitation. The development of cloud cavitation around hydrofoil A consisted of two stages: (1) Attached cavities developed along the surface to the trailing edge; (2) A reentrant jet developed, resulting in shedding and collapse of cluster bubbles or vortex structure. Meanwhile, its development for hydrofoil B included three stages: (1) Attached cavities developed along the surface to the trailing edge, with accumulation and rotation of bubbles at the trailing edge of the hydrofoil affecting the flow field; (2) Development of a reentrant jet resulted in the first shedding of cavities. Interaction and movement of flows from the pressure side and suction side brought liquid water from the pressure side to the suction side of the hydrofoil, finally forming a reentrant jet. The jet kept moving along the surface to the leading edge of the hydrofoil, resulting in large-scale shedding of cloud bubbles. Several vortices appeared and dissipated during the process; (3) Cavities grew and shed again.

  17. Investigation of cavitation as a possible damage mechanism in blast-induced traumatic brain injury.

    Science.gov (United States)

    Goeller, Jacques; Wardlaw, Andrew; Treichler, Derrick; O'Bruba, Joseph; Weiss, Greg

    2012-07-01

    Cavitation was investigated as a possible damage mechanism for war-related traumatic brain injury (TBI) due to an improvised explosive device (IED) blast. When a frontal blast wave encounters the head, a shock wave is transmitted through the skull, cerebrospinal fluid (CSF), and tissue, causing negative pressure at the contrecoup that may result in cavitation. Numerical simulations and shock tube experiments were conducted to determine the possibility of cranial cavitation from realistic IED non-impact blast loading. Simplified surrogate models of the head consisted of a transparent polycarbonate ellipsoid. The first series of tests in the 18-inch-diameter shock tube were conducted on an ellipsoid filled with degassed water to simulate CSF and tissue. In the second series, Sylgard gel, surrounded by a layer of degassed water, was used to represent the tissue and CSF, respectively. Simulated blast overpressure in the shock tube tests ranged from a nominal 10-25 pounds per square inch gauge (psig; 69-170 kPa). Pressure in the simulated CSF was determined by Kulite thin line pressure sensors at the coup, center, and contrecoup positions. Using video taken at 10,000 frames/sec, we verified the presence of cavitation bubbles at the contrecoup in both ellipsoid models. In all tests, cavitation at the contrecoup was observed to coincide temporally with periods of negative pressure. Collapse of the cavitation bubbles caused by the surrounding pressure and elastic rebound of the skull resulted in significant pressure spikes in the simulated CSF. Numerical simulations using the DYSMAS hydrocode to predict onset of cavitation and pressure spikes during cavity collapse were in good agreement with the tests. The numerical simulations and experiments indicate that skull deformation is a significant factor causing cavitation. These results suggest that cavitation may be a damage mechanism contributing to TBI that requires future study.

  18. Development of a Cavitation Erosion Resistant Advanced Material System

    National Research Council Canada - National Science Library

    Kendrick, Light H; Caccese, Vincent

    2005-01-01

    .... Historically, neither of these materials has performed well in a cavitating environment. The objective of this effort was to evaluate cavitation erosion protection alternatives for a GRP composite structure used in a cavitating environment...

  19. Application of signal analysis to cavitation

    Science.gov (United States)

    Martin, C. S.; Veerabhadra Rao, P.

    1984-01-01

    The diagnostic facilities of the cross power spectrum and the coherence function have been employed to enhance the identification of not only the inception of cavitation, but also its level. Two piezoelectric pressure transducers placed in the downstream chamber of a model spool valve undergoing various levels of cavitation allowed for the use of both functions - the phase angle of the complex cross spectrum and the dimensionless coherence function - to sense clearly the difference between noise levels associated with a noncavitating jet from those once cavitation inception is attained. The cavitation noise within the chamber exhibited quite a regular character in terms of the phase difference between instruments for limited cavitation. Varying cavitation levels clearly illustrated the effect of bubble size on the attendant frequency range for which there was an extremely high coherence or nearly perfect causality.

  20. Inertial cavitation in theranostic nanoemulsions with simultaneous pulsed laser and low frequency ultrasound excitation

    Science.gov (United States)

    Arnal, Bastien; Wei, Chen-Wei; Xia, Jinjun; Pelivanov, Ivan M.; Lombardo, Michael; Perez, Camilo; Matula, Thomas J.; Pozzo, Danilo; O'Donnell, Matthew

    2014-03-01

    Ultrasound-induced inertial cavitation is a mechanical process used for site-localized therapies such as non-invasive surgery. Initiating cavitation in tissue requires very high intensity focused ultrasound (HIFU) and low-frequencies. Hence, some applications like thrombolysis require targeted contrast agents to reduce peak intensities and the potential for secondary effects. A new type of theranostic nanoemulsion has been developed as a combined ultrasound (US)/photoacoustic(PA) agent for molecular imaging and therapy. It includes a nanoscale emulsion core encapsulated with a layer of gold nanospheres at the water/ oil interface. Its optical absorption exhibits a spectrum broadened up to 1100 nm, opening the possibility that 1064 nm light can excite cavitation nuclei. If optically-excited nuclei are produced at the same time that a low-frequency US wave is at peak negative pressure, then highly localized therapies based on acoustic cavitation may be enabled at very low US pressures. We have demonstrated this concept using a low-cost, low energy, portable 1064 nm fiber laser in conjunction with a 1.24 MHz US transducer for simultaneous laser/US excitation of nanoemulsions. Active cavitation detection from backscattered signals indicated that cavitation can be initiated at very low acoustic pressures (less than 1 MPa) when laser excitation coincides with the rarefaction phase of the acoustic wave, and that no cavitation is produced when light is delivered during the compressive phase. US can sustain cavitation activity during long acoustic bursts and stimulate diffusion of the emulsion, thus increasing treatment speed. An in vitro clot model has been used to demonstrate combined US and laser excitation of the nanoemulsion for efficient thrombolysis.

  1. Computation and analysis of cavitating flow in Francis-class hydraulic turbines

    Science.gov (United States)

    Leonard, Daniel J.

    Hydropower is the most proven renewable energy technology, supplying the world with 16% of its electricity. Conventional hydropower generates a vast majority of that percentage. Although a mature technology, hydroelectric generation shows great promise for expansion through new dams and plants in developing hydro countries. Moreover, in developed hydro countries, such as the United States, installing generating units in existing dams and the modern refurbishment of existing plants can greatly expand generating capabilities with little to no further impact on the environment. In addition, modern computational technology and fluid dynamics expertise has led to substantial improvements in modern turbine design and performance. Cavitation has always presented a problem in hydroturbines, causing performance breakdown, erosion, damage, vibration, and noise. While modern turbines are usually designed to be cavitation-free at their best efficiency point, due to the variable demand of the energy market it is fairly common to operate at off-design conditions. Here, cavitation and its deleterious effects are unavoidable, and hence, cavitation is a limiting factor on the design and operation of these turbines. Multiphase Computational Fluid Dynamics (CFD) has been used in recent years to model cavitating flow for a large range of problems, including turbomachinery. However, CFD of cavitating flow in hydroturbines is still in its infancy. This dissertation presents steady-periodic Reynolds-averaged Navier-Stokes simulations of a cavitating Francis-class hydroturbine at model and prototype scales. Computational results of the reduced-scale model and full-scale prototype, undergoing performance breakdown, are compared with empirical model data and prototype performance estimations based on standard industry scalings from the model data. Mesh convergence of the simulations is also displayed. Comparisons are made between the scales to display that cavitation performance breakdown

  2. Contributions to some cavitation problems in turbomachinery

    OpenAIRE

    Arakeri, VH

    1999-01-01

    In the present article, three problems associated with cavitation in turbomachinery are discussed. The first one deals with the potential application of recent understanding in cavitation inception to similar problems in turbomachinery. The second considers the thermodynamic effects in developed cavitation. This has relevance to turbopump operation using fluids other than water. Old correlations to predict the above effect are summarized and a new correlation is proposed. Lastly, the possible...

  3. Modeling of Cavitating Flow through Waterjet Propulsors

    Science.gov (United States)

    2015-02-18

    OCT-11 -31-DEC-14 To) 4. TITLE AND SUBTITLE Modeling of Cavitating Flow through Waterjet Propulsors 5a. CONTRACT NUMBER 5b. GRANT NUMBER N00014-12...239-18 Modeling of Cavitating Flow through Waterjet Propulsors Jules W. Lindau The Pennsylvania State University, Applied Research Laboratory, State...flow nature, waterjets are expected to maintain resistance to cavitation , are amenable to ad- vanced concepts such as thrust vectoring, should

  4. Method of similarity for cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Espanet, L.; Tekatlian, A.; Barbier, D. [CEA/Cadarache, Dept. d' Etudes des Combustibles (DEC), 13 - Saint-Paul-lez-Durance (France); Gouin, H. [Aix-Marseille-3 Univ., 13 - Marseille (France). Laboratoire de Modelisation en Mecanique et Thermodynamique

    1998-07-01

    The knowledge of possible cavitation in subassembly nozzles of the fast reactor core implies the realization of a fluid dynamic model test. We propose a method of similarity based on the non-dimensionalization of the equation of motion for viscous capillarity fluid issued from the Cahn and Hilliard model. Taking into account the dissolved gas effect, a condition of compatibility is determined. This condition must be respected by the fluid in experiment, along with the scaling between the two similar flows. (author)

  5. Acoustic cavitation mechanism: a nonlinear model.

    Science.gov (United States)

    Vanhille, Christian; Campos-Pozuelo, Cleofé

    2012-03-01

    During acoustic cavitation process, bubbles appear when acoustic pressure reaches a threshold value in the liquid. The ultrasonic field is then submitted to the action of the bubbles. In this paper we develop a model to analyze the cavitation phenomenon in one-dimensional standing waves, based on the nonlinear code SNOW-BL. Bubbles are produced where the minimum rarefaction pressure peak exceeds the cavitation threshold. We show that cavitation bubbles appear at high amplitude and drastically affect (dissipation, dispersion, and nonlinearity) the ultrasonic field. This paper constitutes the first work that associates the nonlinear ultrasonic field to a bubble generation process. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Evidence for sustained cortical involvement in peripheral stretch reflex during the full long latency reflex period.

    Science.gov (United States)

    Perenboom, M J L; Van de Ruit, M; De Groot, J H; Schouten, A C; Meskers, C G M

    2015-01-01

    Adaptation of reflexes to environment and task at hand is a key mechanism in optimal motor control, possibly regulated by the cortex. In order to locate the corticospinal integration, i.e. spinal or supraspinal, and to study the critical temporal window of reflex adaptation, we combined transcranial magnetic stimulation (TMS) and upper extremity muscle stretch reflexes at high temporal precision. In twelve participants (age 49 ± 13 years, eight male), afferent signals were evoked by 40 ms ramp and subsequent hold stretches of the m. flexor carpi radialis (FCR). Motor conduction delays (TMS time of arrival at the muscle) and TMS-motor threshold were individually assessed. Subsequently TMS pulses at 96% of active motor threshold were applied with a resolution of 5-10 ms between 10 ms before and 120 ms after onset of series of FCR stretches. Controlled for the individually assessed motor conduction delay, subthreshold TMS was found to significantly augment EMG responses between 60 and 90 ms after stretch onset. This sensitive temporal window suggests a cortical integration consistent with a long latency reflex period rather than a spinal integration consistent with a short latency reflex period. The potential cortical role in reflex adaptation extends over the full long latency reflex period, suggesting adaptive mechanisms beyond reflex onset. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Sound signature of propeller tip vortex cavitation

    NARCIS (Netherlands)

    Pennings, P.C.; Westerweel, J.; Van Terwisga, T.J.C.

    2015-01-01

    The design of an efficient propeller is limited by the harmful effects of cavitation. The insuffcient understanding of the role of vortex cavitation in noise and vibration reduces the maximum effciency by a necessary safety margin. The aim in the present study is to directly relate propeller

  8. Interaction of cavitation bubbles on a wall

    NARCIS (Netherlands)

    Bremond, Nicolas; Bremond, N.P.; Arora, M.; Dammer, S.M.; Lohse, Detlef

    2006-01-01

    We report experimental and numerical investigations on the dynamics of the cavitation of bubbles on a solid surface and the interaction between them with the help of controlled cavitation nuclei: hemispherical bubbles are nucleated from hydrophobic microcavities that act as gas traps when the

  9. Mapping cavitation activity around dental ultrasonic tips.

    Science.gov (United States)

    Walmsley, A Damien; Lea, Simon C; Felver, Bernhard; King, David C; Price, Gareth J

    2013-05-01

    Cavitation arising within the water around the oscillating ultrasonic scaler tip is an area that may lead to advances in enhancing biofilm removal. The aim of this study is to map the occurrence of cavitation around scaler tips under loaded conditions. Two designs of piezoelectric ultrasonic scaling probes were evaluated with a scanning laser vibrometer and luminol dosimetric system under loaded (100 g/200 g) and unloaded conditions. Loads were applied to the probe tips via teeth mounted in a load-measuring apparatus. There was a positive correlation between probe displacement amplitude and cavitation production for ultrasonic probes. The position of cavitation at the tip of each probe was greater under loaded conditions than unloaded and for the longer P probe towards the tip. Whilst increasing vibration displacement amplitude of ultrasonic scalers increases the occurrence of cavitation, factors such as the length of the probe influence the amount of cavitation activity generated. The application of load affects the production of cavitation at the most clinically relevant area-the tip. Loading and the design of ultrasonic scalers lead to maximising the occurrence of the cavitation at the tip and enhance the cleaning efficiency of the scaler.

  10. Comparison of Different Mathematical Models of Cavitation

    Directory of Open Access Journals (Sweden)

    Dorota HOMA

    2014-12-01

    Full Text Available Cavitation occurs during the flow when local pressure drops to the saturation pressure according to the temperature of the flow. It includes both evaporation and condensation of the vapor bubbles, which occur alternately with high frequency. Cavitation can be very dangerous, especially for pumps, because it leads to break of flow continuity, noise, vibration, erosion of blades and change in pump’s characteristics. Therefore it is very important for pump designers and users to avoid working in cavitation conditions. Simulation of flow can be very useful in that and can indicate if there is risk of cavitating flow occurrence. As this is a multiphase flow and quite complicated phenomena, there are a few mathematical models describing it. The aim of this paper is to make a short review of them and describe their approach to model cavitation. It is desirable to know differences between them to model this phenomenon properly.

  11. Quantitative Frequency-Domain Passive Cavitation Imaging

    Science.gov (United States)

    Haworth, Kevin J.; Bader, Kenneth B.; Rich, Kyle T.; Holland, Christy K.; Mast, T. Douglas

    2017-01-01

    Passive cavitation detection has been an instrumental technique for measuring cavitation dynamics, elucidating concomitant bioeffects, and guiding ultrasound therapies. Recently, techniques have been developed to create images of cavitation activity to provide investigators with a more complete set of information. These techniques use arrays to record and subsequently beamform received cavitation emissions, rather than processing emissions received on a single-element transducer. In this paper, the methods for performing frequency-domain delay, sum, and integrate passive imaging are outlined. The method can be applied to any passively acquired acoustic scattering or emissions, including cavitation emissions. In order to compare data across different systems, techniques for normalizing Fourier transformed data and converting the data to the acoustic energy received by the array are described. A discussion of hardware requirements and alternative imaging approaches are additionally outlined. Examples are provided in MATLAB. PMID:27992331

  12. Vapor Cavitation in Dynamically Loaded Journal Bearings

    Science.gov (United States)

    Jacobson, B. O.; Hamrock, B. J.

    1983-01-01

    High speed motion camera experiments were performed on dynamically loaded journal bearings. The length to diameter ratio of the bearing, the speed of the roller and the tube, the surface material of the roller, and the static and dynamic eccentricity of the bearing were varied. One hundred and thirty-four cases were filmed. The occurrence of vapor cavitation was clearly evident in the films and figures presented. Vapor cavitation was found to occur when the tensile stress applied to the oil exceeded the tensile strength of the oil or the binding of the oil to the surface. The physical situation in which vapor cavitation occurs is during the squeezing and sliding motion within a bearing. Besides being able to accurately capture the vapor cavitation on film, an analysis of the formation and collapse of the cavitation bubbles and characteristics of the bubble content are presented.

  13. J-2X Turbopump Cavitation Diagnostics

    Science.gov (United States)

    Santi, I. Michael; Butas, John P.; Tyler, Thomas R., Jr.; Aguilar, Robert; Sowers, T. Shane

    2010-01-01

    The J-2X is the upper stage engine currently being designed by Pratt & Whitney Rocketdyne (PWR) for the Ares I Crew Launch Vehicle (CLV). Propellant supply requirements for the J-2X are defined by the Ares Upper Stage to J-2X Interface Control Document (ICD). Supply conditions outside ICD defined start or run boxes can induce turbopump cavitation leading to interruption of J-2X propellant flow during hot fire operation. In severe cases, cavitation can lead to uncontained engine failure with the potential to cause a vehicle catastrophic event. Turbopump and engine system performance models supported by system design information and test data are required to predict existence, severity, and consequences of a cavitation event. A cavitation model for each of the J-2X fuel and oxidizer turbopumps was developed using data from pump water flow test facilities at Pratt & Whitney Rocketdyne (PWR) and Marshall Space Flight Center (MSFC) together with data from Powerpack 1A testing at Stennis Space Center (SSC) and from heritage systems. These component models were implemented within the PWR J-2X Real Time Model (RTM) to provide a foundation for predicting system level effects following turbopump cavitation. The RTM serves as a general failure simulation platform supporting estimation of J-2X redline system effectiveness. A study to compare cavitation induced conditions with component level structural limit thresholds throughout the engine was performed using the RTM. Results provided insight into system level turbopump cavitation effects and redline system effectiveness in preventing structural limit violations. A need to better understand structural limits and redline system failure mitigation potential in the event of fuel side cavitation was indicated. This paper examines study results, efforts to mature J-2X turbopump cavitation models and structural limits, and issues with engine redline detection of cavitation and the use of vehicle-side abort triggers to augment the

  14. Visualization of cavitating micro jets

    Directory of Open Access Journals (Sweden)

    Knížat Branislav

    2012-04-01

    Full Text Available The paper deals with one experimental set up integrated for research of the cavitating micro flows, which is incipient behind the micro channel or micro discharge nozzle outlet port. Experimental system is integrated from three major systems: hydraulic circuit with installed discharge nozzle (or micro channel, subsystem for data acquisition and data processing (DAQ system and vision system compound of high speed video camera and pulse light source with highfrequency repetition. First few results of experiments (parameters such as inlet pressure, downstream pressure were changed is also discussed.;

  15. Enterobacter Asburiae Pneumonia with Cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Seung Woo; Heo, Jeong Nam; Park, Choong Ki [Dept. of Radiology, Hanyang University College of Medicine, Guri Hospital, Guri (Korea, Republic of); Choi, Yo Won; Jeon, Seok Chol [Dept. of Radiology, Hanyang University College of Medicine, Seoul Hospital, Seoul (Korea, Republic of)

    2013-03-15

    Enterobacter species have increasingly been identified as pathogens over the past several decades. These bacterial species have become more important because most are resistant to cephalothin and cefoxitin, and can produce extended-spectrum {beta}-lactamase. Enterobacter asburiae (E. asburiae) is a gram-negative rod of the family Enterobacteriaceae, named in 1986. Since then, there has been only one clinical report of E. asburiae pneumonia. We report a case of E. asburiae pneumonia with cavitation and compare it with the previous case.

  16. Superhigh Temperatures and Acoustic Cavitation

    CERN Document Server

    Belyaev, V B; Miller, M B; Sermyagin, A V; Topolnikov, A S

    2003-01-01

    The experimental results on thermonuclear synthesis under acoustic cavitation have been analyzed with the account of the latest data and their discussion. The analysis testifies that this avenue of research is a very promising one. The numerical calculations of the D(d, n)^{3}He reaction rate in the deuterated acetone (C_{3}D_{6}O) under the influence of ultrasound depending on T environment temperature within the range T=249-295 K have been carried out within the framework of hydrodynamic model. The results show that it is possible to improve substantially the effect/background relationship in experiments by decreasing the fluid temperature twenty-thirty degrees below zero.

  17. Effect of hydrodynamic cavitation on zooplankton: A tool for disinfection

    Digital Repository Service at National Institute of Oceanography (India)

    Sawant, S.S.; Anil, A.C.; Venkat, K.; Gaonkar, C.; Kolwalkar, J.; Khandeparker, L.; Desai, D.V.; Mahulkar, A.V.; Ranade, V.V.; Pandit, A.B.

    in the constriction. Where, I = cell count in intake water (pre-cavitation), D = cell count in discharge water (post-cavitation) 3. Cavitation number and its relevance to the energy delivered to the cavitating system Applying Bernoulli’s theorem at point 2 (vena...

  18. Suppression of Cavitation Instabilities in an Inducer by J-Groove

    OpenAIRE

    Shimiya, Noriyuki; Fujii, Akira; Horiguchi, Hironori; Uchiumi, Masaharu; Kurokawa, Junichi; Tsujimoto, Yoshinobu

    2006-01-01

    The suppression of cavitation instabilities was attempted through the control of tip leakage vortex cavitation. The control was made by using shallow grooves, called J-groove, on the casing wall. With J-groove, the onset regions of the rotating cavitation and the asymmetric cavitation could be diminished. However, a cavitation surge appeared at higher cavitation numbers. From the observation of cavitation, it was found that the cavitation surge occurred when the tip leakage vortex cavitation ...

  19. An Anticipatory Model of Cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, G.O.; Dress, W.B., Jr.; Hylton, J.O.; Kercel, S.W.

    1999-04-05

    The Anticipatory System (AS) formalism developed by Robert Rosen provides some insight into the problem of embedding intelligent behavior in machines. AS emulates the anticipatory behavior of biological systems. AS bases its behavior on its expectations about the near future and those expectations are modified as the system gains experience. The expectation is based on an internal model that is drawn from an appeal to physical reality. To be adaptive, the model must be able to update itself. To be practical, the model must run faster than real-time. The need for a physical model and the requirement that the model execute at extreme speeds, has held back the application of AS to practical problems. Two recent advances make it possible to consider the use of AS for practical intelligent sensors. First, advances in transducer technology make it possible to obtain previously unavailable data from which a model can be derived. For example, acoustic emissions (AE) can be fed into a Bayesian system identifier that enables the separation of a weak characterizing signal, such as the signature of pump cavitation precursors, from a strong masking signal, such as a pump vibration feature. The second advance is the development of extremely fast, but inexpensive, digital signal processing hardware on which it is possible to run an adaptive Bayesian-derived model faster than real-time. This paper reports the investigation of an AS using a model of cavitation based on hydrodynamic principles and Bayesian analysis of data from high-performance AE sensors.

  20. Released air during vapor and air cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Jablonská, Jana, E-mail: jana.jablonska@vsb.cz; Kozubková, Milada, E-mail: milada.kozubkova@vsb.cz [VŠB-Technical University of Ostrava, Faculty of Mechanical Engineering, Department of Hydromechanics and Hydraulic Equipment, 17. listopadu 15, 708 33 Ostrava-Poruba (Czech Republic)

    2016-06-30

    Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurements for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.

  1. Experimental and numerical studies on super-cavitating flow of axisymmetric cavitators

    Directory of Open Access Journals (Sweden)

    Byoung-Kwon Ahn

    2010-03-01

    Full Text Available Recently underwater systems moving at high speed such as a super-cavitating torpedo have been studied for their practical advantage of the dramatic drag reduction. In this study we are focusing our attention on super-cavitating flows around axisymmetric cavitators. A numerical method based on inviscid flow is developed and the results for several shapes of the cavitator are presented. First using a potential based boundary element method, we find the shape of the cavitator yielding a sufficiently large enough cavity to surround the body. Second, numerical predictions of supercavity are validated by comparing with experimental observations carried out in a high speed cavitation tunnel at Chungnam National University (CNU CT.

  2. Analyses of cavitation instabilities in ductile metals

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    2007-01-01

    Cavitation instabilities have been predicted for a single void in a ductile metal stressed under high triaxiality conditions. In experiments for a ceramic reinforced by metal particles a single dominant void has been observed on the fracture surface of some of the metal particles bridging a crack...... for the influence of such size-effects on cavitation instabilities are presented. When a metal contains a distribution of micro voids, and the void spacing compared to void size is not extremely large, the surrounding voids may affect the occurrence of a cavitation instability at one of the voids. This has been...

  3. Size-effects on cavitation instabilities

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Tvergaard, Viggo

    2005-01-01

    In metal-ceramic systems the constraint on plastic flow leads to so high stress triaxialities that cavitation instabilities may occur. If the void radius is on the order of magnitude of a characteristic length for the metal, the rate of void growth is reduced, and the possibility of unstable cavity...... triaxiality, where cavitation instabilities are predicted by conventional plasticity theory, such instabilities are also found for the nonlocal theory, but the effects of gradient hardening delay the onset of the instability. Furthermore, in some cases the cavitation stress reaches a maximum and then decays...

  4. Simulation of Cavitation Water Flows

    Directory of Open Access Journals (Sweden)

    Piroz Zamankhan

    2015-01-01

    Full Text Available The air-water mixture from an artificially aerated spillway flowing down to a canyon may cause serious erosion and damage to both the spillway surface and the environment. The location of an aerator, its geometry, and the aeration flow rate are important factors in the design of an environmentally friendly high-energy spillway. In this work, an analysis of the problem based on physical and computational fluid dynamics (CFD modeling is presented. The numerical modeling used was a large eddy simulation technique (LES combined with a discrete element method. Three-dimensional simulations of a spillway were performed on a graphics processing unit (GPU. The result of this analysis in the form of design suggestions may help diminishing the hazards associated with cavitation.

  5. Bacterial microleakage of Cavit, IRM, and TERM.

    Science.gov (United States)

    Deveaux, E; Hildelbert, P; Neut, C; Boniface, B; Romond, C

    1992-11-01

    In this in vitro study, a model system was developed and tested to evaluate the sealing ability of temporary restorative materials used in endodontic access preparations. The materials studied, Cavit, IRM, and TERM, were tested on 40 premolars against a known bacterial species, Streptococcus sanguis. The leakage of bacterial cells was checked 4 and 8 days after initial immersion in the culture. Thermocycling was introduced on the fourth day. After 8 days the cement thicknesses were measured after the teeth had been longitudinally sectioned. Before and after thermocycling, IRM was less leakproof than Cavit (p Cavit, whereas TERM remained leakproof. The thicknesses were as follows: Cavit, 3.73 mm; IRM, 3.45 mm; and TERM, 5.49 mm. There was no statistically significant relationship between thickness and tightness.

  6. CAVITATION SOUNDS DURING CERVICOTHORACIC SPINAL MANIPULATION.

    Science.gov (United States)

    Dunning, James; Mourad, Firas; Zingoni, Andrea; Iorio, Raffaele; Perreault, Thomas; Zacharko, Noah; de Las Peñas, César Fernández; Butts, Raymond; Cleland, Joshua A

    2017-08-01

    No study has previously investigated the side, duration or number of audible cavitation sounds during high-velocity low-amplitude (HVLA) thrust manipulation to the cervicothoracic spine. The primary purpose was to determine which side of the spine cavitates during cervicothoracic junction (CTJ) HVLA thrust manipulation. Secondary aims were to calculate the average number of cavitations, the duration of cervicothoracic thrust manipulation, and the duration of a single cavitation. Quasi-experimental study. Thirty-two patients with upper trapezius myalgia received two cervicothoracic HVLA thrust manipulations targeting the right and left T1-2 articulation, respectively. Two high sampling rate accelerometers were secured bilaterally 25 mm lateral to midline of the T1-2 interspace. For each manipulation, two audio signals were extracted using Short-Time Fourier Transformation (STFT) and singularly processed via spectrogram calculation in order to evaluate the frequency content and number of instantaneous energy bursts of both signals over time for each side of the CTJ. Unilateral cavitation sounds were detected in 53 (91.4%) of 58 cervicothoracic HVLA thrust manipulations and bilateral cavitation sounds were detected in just five (8.6%) of the 58 thrust manipulations; that is, cavitation was significantly (pcavitation was significantly (pcavitations per manipulation was 4.35 (95% CI 2.88, 5.76). The mean duration of a single manipulation was 60.77 ms (95% CI 28.25, 97.42) and the mean duration of a single audible cavitation was 4.13 ms (95% CI 0.82, 7.46). In addition to single-peak and multi-peak energy bursts, spectrogram analysis also demonstrated high frequency sounds, low frequency sounds, and sounds of multiple frequencies for all 58 manipulations. Cavitation was significantly more likely to occur unilaterally, and on the side contralateral to the short-lever applicator contact, during cervicothoracic HVLA thrust manipulation. Clinicians should expect multiple

  7. CAVITATION SOUNDS DURING CERVICOTHORACIC SPINAL MANIPULATION

    Science.gov (United States)

    Mourad, Firas; Zingoni, Andrea; Iorio, Raffaele; Perreault, Thomas; Zacharko, Noah; de las Peñas, César Fernández; Butts, Raymond; Cleland, Joshua A.

    2017-01-01

    Background No study has previously investigated the side, duration or number of audible cavitation sounds during high-velocity low-amplitude (HVLA) thrust manipulation to the cervicothoracic spine. Purpose The primary purpose was to determine which side of the spine cavitates during cervicothoracic junction (CTJ) HVLA thrust manipulation. Secondary aims were to calculate the average number of cavitations, the duration of cervicothoracic thrust manipulation, and the duration of a single cavitation. Study Design Quasi-experimental study Methods Thirty-two patients with upper trapezius myalgia received two cervicothoracic HVLA thrust manipulations targeting the right and left T1-2 articulation, respectively. Two high sampling rate accelerometers were secured bilaterally 25 mm lateral to midline of the T1-2 interspace. For each manipulation, two audio signals were extracted using Short-Time Fourier Transformation (STFT) and singularly processed via spectrogram calculation in order to evaluate the frequency content and number of instantaneous energy bursts of both signals over time for each side of the CTJ. Result Unilateral cavitation sounds were detected in 53 (91.4%) of 58 cervicothoracic HVLA thrust manipulations and bilateral cavitation sounds were detected in just five (8.6%) of the 58 thrust manipulations; that is, cavitation was significantly (pmanipulation was 4.35 (95% CI 2.88, 5.76). The mean duration of a single manipulation was 60.77 ms (95% CI 28.25, 97.42) and the mean duration of a single audible cavitation was 4.13 ms (95% CI 0.82, 7.46). In addition to single-peak and multi-peak energy bursts, spectrogram analysis also demonstrated high frequency sounds, low frequency sounds, and sounds of multiple frequencies for all 58 manipulations. Discussion Cavitation was significantly more likely to occur unilaterally, and on the side contralateral to the short-lever applicator contact, during cervicothoracic HVLA thrust manipulation. Clinicians should expect

  8. Assessment of Cavitation Erosion with a Multiphase Reynolds-Averaged Navier-Stokes Method

    NARCIS (Netherlands)

    Li, Z.R.

    2012-01-01

    Cavitation erosion is one of the remarkable catastrophic consequences of cavitation. Predicting the cavitation aggressiveness quantitatively and predicting the most probable location of cavitation erosion are complex problems that currently still motivate an important amount of basic and applied

  9. Microgeometrical cavitation in oscillating slider contacts

    Science.gov (United States)

    Wietzel, U.

    1994-04-01

    This paper deals with microgeometrically-determined cavitation in oscillating slider bearings. After explaining the difference in the origin of cavitation in journal and linear bearings, the theoretical idea of a computer simulation program on the basis of a combined microhydryodynamic/solid-solid-contact approach is introduced. With the help of this program, slider surface geometry, inertia effects, lubricant properties, normal load, and lubricant film temperatures were found as parameters of microcavitation.

  10. Sonoluminescence and acoustic emission spectra at different stages of cavitation zone development.

    Science.gov (United States)

    Dezhkunov, N V; Francescutto, A; Serpe, L; Canaparo, R; Cravotto, G

    2018-01-01

    The way in which a cavitation zone develops in a focused pulsed ultrasound field is studied in this work. Sonoluminescence (SL), total hydrophone output and cavitation noise spectra have been recorded across a gradual, smooth increase in applied voltage. It is shown that the cavitation zone passes through a number of stages of evolution, according to increasing ultrasound intensity, decreasing pulse period and increasing ultrasound pulse duration. Sonoluminescence is absent in the first phase and the hydrophone output spectra consists of a main line with two or three harmonics whose intensity is much lower than that of the main (fundamental) line. The second stage sees the onset of SL whose intensity increases smoothly and is accompanied by the appearance of higher harmonics and subharmonics in the cavitation noise spectra. In some cases, the wide-band (WBN) component can be seen in noise spectra during the final part of the second stage. In the third stage, SL intensity increases significantly and often quite sharply, while WBN intensity increases in the same manner. This is accompanied by a synchronous increase in the absorption of ultrasound by the cavitation zone, which is manifested in a sharp decrease in the hydrophone output. In the fourth stage, both SL and WBN intensities tend to decrease despite the increased voltage applied to the transducer. Furthermore, the fundamental line tends to decrease in strength as well, despite the increasing ultrasound intensity. The obtained results clearly identify the different stages of cavitation zone development using cavitation noise spectra analyses. We then hypothesize that three of the above stages may be responsible for three known types of ultrasound action on biological cells: damping viability, reversible cell damage (sonoporation) and irreversible damage/cytotoxicity. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Numerical and Experimental Studies of Cavitation Behavior in Water-Jet Cavitation Peening Processing

    Directory of Open Access Journals (Sweden)

    H. Zhang

    2013-01-01

    Full Text Available Water-jet cavitation peening (WCP is a new technology for the surface modification of metallic materials. The cavitation behavior in this process involves complex and changeable physics phenomena, such as high speed, high pressure, multiple phases, phase transition, turbulence, and unstable features. Thus, the cavitation behavior and impact-pressure distribution in WCP have always been key problems in this field. Numerous factors affect the occurrence of cavitation. These factors include flow-boundary conditions, absolute pressure, flow velocity, flow viscosity, surface tension, and so on. Among these factors, pressure and vapor fraction are the most significant. Numerical simulations are performed to determine the flow-field characteristics of both inside and outside the cavitating nozzle of a submerged water jet. The factors that influence the cavitation intensity of pressure are simulated. Fujifilm pressure-sensitive paper is used to measure the distribution of impact pressure along the jet direction during the WCP process. The results show that submerged cavitation jets can induce cavitation both inside and outside a conical nozzle and a convergent-divergent nozzle when the inlet pressure is 32 MPa. Moreover, the shock wave pressure induced by the collapse of the bubble group reaches up to 300 MPa.

  12. Insights into xylem vulnerability to cavitation in Fagus sylvatica L.: phenotypic and environmental sources of variability.

    Science.gov (United States)

    Herbette, Stephane; Wortemann, Remi; Awad, Hosam; Huc, Roland; Cochard, Herve; Barigah, Tete Severien

    2010-11-01

    Xylem vulnerability to cavitation is a key parameter in understanding drought resistance of trees. We determined the xylem water pressure causing 50% loss of hydraulic conductivity (P(50)), a proxy of vulnerability to cavitation, and we evaluated the variability of this trait at tree and population levels for Fagus sylvatica. We checked for the effects of light on vulnerability to cavitation of stem segments together with a time series variation of P(50). Full sunlight-exposed stem segments were less vulnerable to cavitation than shade-exposed ones. We found no clear seasonal change of P(50), suggesting that this trait was designed for a restricted period. P(50) varied for populations settled along a latitudinal gradient, but not for those sampled along an altitudinal gradient. Moreover, mountainside exposure seemed to play a major role in the vulnerability to cavitation of beech populations, as we observed the differences along north-facing sides but not on south-facing sides. Unexpectedly, both north-facing mountainside and northern populations appeared less vulnerable than those grown on the southern mountainside or in the South of France. These results on beech populations were discussed with respect to the results at within-tree level.

  13. Real-time visualization of joint cavitation.

    Directory of Open Access Journals (Sweden)

    Gregory N Kawchuk

    Full Text Available Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking.

  14. Evaluation of Cavitation Erosion Behavior of Commercial Steel Grades Used in the Design of Fluid Machinery

    Science.gov (United States)

    Tzanakis, I.; Bolzoni, L.; Eskin, D. G.; Hadfield, M.

    2017-05-01

    The erosion response under cavitation of different steel grades was assessed by studying the erosion rate, the volume removal, the roughness evolution, and the accumulated strain energy. A 20 kHz ultrasonic transducer with a probe diameter of 5 mm and peak-to-peak amplitude of 50 μm was deployed in distilled water to induce damage on the surface of commercial chromium and carbon steel samples. After a relatively short incubation period, cavitation induced the formation of pits, cracks, and craters whose features strongly depended on the hardness and composition of the tested steel. AISI 52100 chromium steel showed the best performance and is, therefore, a promising design candidate for replacing the existing fluid machinery materials that operate within potential cavitating environments.

  15. Real-Time Two-Dimensional Imaging of Microbubble Cavitation

    NARCIS (Netherlands)

    Vignon, F.; Shi, W.T.; Powers, J.E.; Liu, J.; Drvol, L.; Lof, J.; Everbach, C.; Gao, S.; Xie, F.; Porter, T.

    2011-01-01

    Ultrasound cavitation of microbubble contrast agents has a potentialfor therapeutic applications, including sonothrombolysis in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (e.g. stable versus inertial forms of

  16. Cavitation Measurement during Sonic and Ultrasonic Activated Irrigation

    NARCIS (Netherlands)

    Macedo, Ricardo; Verhaagen, Bram; Rivas, David Fernandez; Versluis, Michel; Wesselink, Paul; van der Sluis, Luc

    Introduction: The aims of this study were to quantify and to visualize the possible occurrence of transient cavitation (bubble formation and implosion) during sonic and ultrasonic (UAI) activated irrigation. Methods: The amount of cavitation generated around several endodontic instruments was

  17. Advanced experimental and numerical techniques for cavitation erosion prediction

    CERN Document Server

    Chahine, Georges; Franc, Jean-Pierre; Karimi, Ayat

    2014-01-01

    This book provides a comprehensive treatment of the cavitation erosion phenomenon and state-of-the-art research in the field. It is divided into two parts. Part 1 consists of seven chapters, offering a wide range of computational and experimental approaches to cavitation erosion. It includes a general introduction to cavitation and cavitation erosion, a detailed description of facilities and measurement techniques commonly used in cavitation erosion studies, an extensive presentation of various stages of cavitation damage (including incubation and mass loss), and insights into the contribution of computational methods to the analysis of both fluid and material behavior. The proposed approach is based on a detailed description of impact loads generated by collapsing cavitation bubbles and a physical analysis of the material response to these loads. Part 2 is devoted to a selection of nine papers presented at the International Workshop on Advanced Experimental and Numerical Techniques for Cavitation Erosion (Gr...

  18. Drag Reducing and Cavitation Resistant Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Pease, Leonard F.

    2016-12-28

    Client, Green Building Systems (GBS), presented PNNL a coating reported to reduce drag and prevent cavitation damage on marine vessels, turbines and pumps. The composition of the coating remains proprietary but has as constituents including silicon oxides, aliphatic carbon chains, and fluorine rich particles. The coating is spray applied to surfaces. Prior GBS testing and experiments suggest reduction of both drag and cavitation on industrial scale propellers, but the underlying mechanism for these effects remains unclear. Yet, the application is compelling because even modest reductions in drag to marine vessels and cavitation to propellers and turbines present a significant economic and environmental opportunity. To discern among possible mechanisms, PNNL considered possible mechanisms with the client, executed multiple experiments, and completed one theoretical analysis (see appendix). The remainder of this report first considers image analysis to gain insight into drag reduction mechanisms and then exposes the coating to cavitation to explore its response to an intensely cavitating environment. Although further efforts may be warranted to confirm mechanisms, this report presents a first investigation into these coatings within the scope and resources of the technology assistance program (TAP).

  19. Mechanics modelling of fern cavitation catapult

    Science.gov (United States)

    Kang, Jingtian; Li, Kai; Tan, Huifeng; Wang, Changguo; Cai, Shengqiang

    2017-12-01

    Cavitation is often regarded as a failure mode in soft materials. An intriguing phenomenon has been recently discovered that fern sporangium can take advantage of drying-induced cavitation instability in annulus cells to disperse spores at an extraordinarily high acceleration. Briefly, the decrease of environmental humidity causes continuous bending of the sporangium and growth of cavities inside the annulus cells, with the elastic energy accumulated in sporangium walls. When the humidity is lower than a critical value, the cavities suddenly expand dramatically inside the cells, causing a quick release of the elastic energy stored in the annular structure. As a result, like a catapult, the sporangium snaps back and ejects the seeds at a high speed. Motivated by the observation, in this article, we study cavitation instability in a similar structure as the sporangium. To simplify the problem, in our model, the mechanics of cells in the sporangium are described by the polymer gel model, while the sporangium wall is modelled as a hyperelastic material. When the environmental humidity is lower than a critical value, through energetic analyses, we can predict the cavitation catapult phenomenon using the model. We hope that our study in this article can provide useful insights into the bio-inspired design of structures which can take advantage of cavitation instability in soft materials.

  20. The issue of cavitation number value in studies of water treatment by hydrodynamic cavitation.

    Science.gov (United States)

    Šarc, Andrej; Stepišnik-Perdih, Tadej; Petkovšek, Martin; Dular, Matevž

    2017-01-01

    Within the last years there has been a substantial increase in reports of utilization of hydrodynamic cavitation in various applications. It has came to our attention that many times the results are poorly repeatable with the main reason being that the researchers put significant emphasis on the value of the cavitation number when describing the conditions at which their device operates. In the present paper we firstly point to the fact that the cavitation number cannot be used as a single parameter that gives the cavitation condition and that large inconsistencies in the reports exist. Then we show experiments where the influences of the geometry, the flow velocity, the medium temperature and quality on the size, dynamics and aggressiveness of cavitation were assessed. Finally we show that there are significant inconsistencies in the definition of the cavitation number itself. In conclusions we propose a number of parameters, which should accompany any report on the utilization of hydrodynamic cavitation, to make it repeatable and to enable faster progress of science and technology development. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Static and Transient Cavitation Threshold Measurements for Mercury

    Energy Technology Data Exchange (ETDEWEB)

    Moraga, F.; Taleyarkhan, R.P.

    1999-11-14

    Transient and static cavitation thresholds for mercury as a function of the cover gas (helium or air), and pressure are reported. Both static and transient cavitation onset pressure thresholds increase linearly with cover gas pressure. Additionally, the cavitation thresholds as a function of dissolved gases were also measured and are reported.

  2. Noise Caused by Cavitating Butterfly and Monovar Valves

    Science.gov (United States)

    HASSIS, H.

    1999-08-01

    An experimental study of the effects of cavitation was carried out through an analysis of cavitating Butterfly and Monovar values. Focus is particularly placed on both unsteady pressure and acoustic pressure fluctuations. In this paper, the effects of cavitation on local fluctuation pressure (turbulence), acoustic propagation (damping and sound velocity), resonance frequencies and level of noise are presented.

  3. aluminium alloy by ultrasonic cavitation peening

    Directory of Open Access Journals (Sweden)

    Janka Styková

    2017-01-01

    Full Text Available This article presents first results of the experimental investigation of the influence of the cavitation shot less peening process on the properties of stainless steel and aluminium alloy specimens. The cavitation field was generated by an ultrasonic horn submerged in water and operated by an ultrasonic generator. The temperature of the water was controlled by thermometer and adjusted by separate water cooling system. The mass loss, the mass loss rate and the modification of the surface hardness are evaluated for different cavitation exposure intervals. The mass loss was measured by micro weighing scale and the surface hardness by the micro-hardness meter. The presented results indicates the significant improvement in the surface hardness for both tested materials.

  4. Inducer Hydrodynamic Forces in a Cavitating Environment

    Science.gov (United States)

    Skelley, Stephen E.

    2004-01-01

    Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional

  5. Analogy between fluid cavitation and fracture mechanics

    Science.gov (United States)

    Hendricks, R. C.; Mullen, R. L.; Braun, M. J.

    1983-01-01

    When the stresses imposed on a fluid are sufficiently large, rupture or cavitation can occur. Such conditions can exist in many two-phase flow applications, such as the choked flows, which can occur in seals and bearings. Nonspherical bubbles with large aspect ratios have been observed in fluids under rapid acceleration and high shear fields. These bubbles are geometrically similar to fracture surface patterns (Griffith crack model) existing in solids. Analogies between crack growth in solid and fluid cavitation are proposed and supported by analysis and observation (photographs). Healing phenomena (void condensation), well accepted in fluid mechanics, have been observed in some polymers and hypothesized in solid mechanics. By drawing on the strengths of the theories of solid mechanics and cavitation, a more complete unified theory can be developed.

  6. Towards numerical prediction of cavitation erosion.

    Science.gov (United States)

    Fivel, Marc; Franc, Jean-Pierre; Chandra Roy, Samir

    2015-10-06

    This paper is intended to provide a potential basis for a numerical prediction of cavitation erosion damage. The proposed method can be divided into two steps. The first step consists in determining the loading conditions due to cavitation bubble collapses. It is shown that individual pits observed on highly polished metallic samples exposed to cavitation for a relatively small time can be considered as the signature of bubble collapse. By combining pitting tests with an inverse finite-element modelling (FEM) of the material response to a representative impact load, loading conditions can be derived for each individual bubble collapse in terms of stress amplitude (in gigapascals) and radial extent (in micrometres). This step requires characterizing as accurately as possible the properties of the material exposed to cavitation. This characterization should include the effect of strain rate, which is known to be high in cavitation erosion (typically of the order of several thousands s(-1)). Nanoindentation techniques as well as compressive tests at high strain rate using, for example, a split Hopkinson pressure bar test system may be used. The second step consists in developing an FEM approach to simulate the material response to the repetitive impact loads determined in step 1. This includes a detailed analysis of the hardening process (isotropic versus kinematic) in order to properly account for fatigue as well as the development of a suitable model of material damage and failure to account for mass loss. Although the whole method is not yet fully operational, promising results are presented that show that such a numerical method might be, in the long term, an alternative to correlative techniques used so far for cavitation erosion prediction.

  7. Cavitation Inception in Immersed Jet Shear Flows

    Science.gov (United States)

    Lockett, R. D.; Ndamuso, N.; Price, R.

    2015-12-01

    Cavitation inception occurring in immersed jets was investigated in a purpose-built mechanical flow rig. The rig utilized custom-built cylindrical and conical nozzles to direct high-velocity jets of variable concentration n-octane-hexadecane mixtures into a fused silica optically accessible receiver. The fluid pressure upstream and down-stream of the nozzles were manually controlled. The study employed a variety of acrylic and metal nozzles. The results show that the critical upstream pressure to downstream pressure ratio for incipient cavitation decreases with increasing n-octane concentration for the cylindrical nozzles, and increases with increasing n-octane concentration for the conical nozzle.

  8. The Impact of Manifold-to-Orifice Turning Angle on Sharp-Edge Orifice Flow Characteristics in both Cavitation and Non-Cavitation Turbulent Flow Regimes (Preprint)

    National Research Council Canada - National Science Library

    Nurick, W. H; Ohanian, T; Talley, D. G; Strakey, P. A

    2007-01-01

    .... This paper deals with predicting the initiation of cavitation, cavitation impacts on Cc, and non-cavitation impacts on Cd from L/D of 5 sharp-edge orifices with both single angle and compound angle directional flow...

  9. Experimental investigation of hydrodynamic cavitation through orifices of different geometries

    Directory of Open Access Journals (Sweden)

    Rudolf Pavel

    2017-01-01

    Full Text Available Hydrodynamic cavitation in single and multihole orifices was experimentally investigated to assess their hydraulic characteristics: loss coefficients, inception cavitation number, cavitation number for transition to supercavitation. Significant difference for singlehole and multihole orifices was observed in terms of the measured loss coefficient. It is significantly more effective to use multihole orifices, where energy dissipation is much lower.It was found that using scaling factor given by ratio of orifice thickness suggests linear behaviour of both loss coefficient and inception cavitation number. Orifices seem to be convenient choice as flow constriction devices inducing cavitation due to their simplicity.

  10. Influence of the empirical coefficients of cavitation model on predicting cavitating flow in the centrifugal pump

    Directory of Open Access Journals (Sweden)

    Hou-lin Liu

    2014-03-01

    Full Text Available The phenomenon of cavitation is an unsteady flow, which is nearly inevitable in pump. It would degrade the pump performance, produce vibration and noise and even damage the pump. Hence, to improve accuracy of the numerical prediction of the pump cavitation performance is much desirable. In the present work, a homogenous model, the Zwart-Gerber-Belamri cavitation model, is considered to investigate the influence of the empirical coefficients on predicting the pump cavitation performance, concerning a centrifugal pump. Three coefficients are analyzed, namely the nucleation site radius, evaporation and condensation coefficients. Also, the experiments are carried out to validate the numerical simulations. The results indicate that, to get a precise prediction, the approaches of declining the initial bubble radius, the condensation coefficient or increasing the evaporation coefficient are all feasible, especially for declining the condensation coefficient, which is the most effective way.

  11. Review on Lithotripsy and Cavitation in Urinary Stone Therapy.

    Science.gov (United States)

    Ghorbani, Morteza; Oral, Ozlem; Ekici, Sinan; Gozuacik, Devrim; Kosar, Ali

    2016-01-01

    Cavitation is the sudden formation of vapor bubbles or voids in liquid media and occurs after rapid changes in pressure as a consequence of mechanical forces. It is mostly an undesirable phenomenon. Although the elimination of cavitation is a major topic in the study of fluid dynamics, its destructive nature could be exploited for therapeutic applications. Ultrasonic and hydrodynamic sources are two main origins for generating cavitation. The purpose of this review is to give the reader a general idea about the formation of cavitation phenomenon and existing biomedical applications of ultrasonic and hydrodynamic cavitation. Because of the high number of the studies on ultrasound cavitation in the literature, the main focus of this review is placed on the lithotripsy techniques, which have been widely used for the treatment of urinary stones. Accordingly, cavitation phenomenon and its basic concepts are presented in Section II. The significance of the ultrasound cavitation in the urinary stone treatment is discussed in Section III in detail and hydrodynamic cavitation as an important alternative for the ultrasound cavitation is included in Section IV. Finally, side effects of using both ultrasound and hydrodynamic cavitation in biomedical applications are presented in Section V.

  12. Seasonality of cavitation and frost fatigue in Acer mono Maxim.

    Science.gov (United States)

    Zhang, Wen; Feng, Feng; Tyree, Melvin T

    2017-12-08

    Although cavitation is common in plants, it is unknown whether the cavitation resistance of xylem is seasonally constant or variable. We tested the changes in cavitation resistance of Acer mono before and after a controlled cavitation-refilling and freeze-thaw cycles for a whole year. Cavitation resistance was determined from 'vulnerability curves' showing the percent loss of conductivity (PLC) versus xylem tension. Cavitation fatigue was defined as a reduction of cavitation resistance following a cavitation-refilling cycle while frost fatigue was caused by a freeze-thaw cycle. A. mono developed seasonal changes in native embolisms; values were relatively high during winter but relatively low and constant throughout the growing season. Cavitation fatigue occurred and changed seasonally during the 12-month cycle; the greatest fatigue response occurred during summer and the weakest during winter, and the transitions occurred during spring and autumn. A. mono was highly resistant to frost damage during the relatively mild winter months; however, a quite different situation occurred during the growing season, as the seasonal trend of frost fatigue was strikingly similar to that of cavitation fatigue. Seasonality changes in cavitation resistance may be caused by seasonal changes in the mechanical properties of the pit membranes. This article is protected by copyright. All rights reserved.

  13. Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation.

    Science.gov (United States)

    Bai, Fushi; Saalbach, Kai-Alexander; Wang, Liang; Wang, Xiaogeng; Twiefel, Jens

    2017-12-05

    During ultrasonic cavitation peening, bubbles repeatedly form and collapse, which leads to high impact loads on the treated surface. At the initial stage of ultrasonic cavitation peening, the most obvious change is plastic deformation instead of mass loss on the treated specimen surface. Meanwhile the plastic deformation is beneficial for mechanical surface properties. As the cavitation exposure time increases, erosion and damage are inflicted on the metal surface due to the increase in the number of collapse events. In this respect, the treatment time is a key parameter to improve the specimen surface properties during this manufacturing process. However, the influence of treatment time on the surface properties has not yet been thoroughly investigated. In this paper, it is the first time to utilize the plastic deformation to evaluate the optimal treatment time at different input power. The plastic deformation can be deduced by the mass loss and the volume change on the treated specimen surface. Using plastic deformation, the modification of surface hardness and roughness are investigated at different cavitation exposure intervals and vibration amplitudes. It is found that significant improvement of the microhardness on the treated surface occurs at the end of incubation period. Higher vibration amplitudes of the horn tip lead to shorter incubation period and higher microhardness. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Prevention of Pressure Oscillations in Modeling a Cavitating Acoustic Fluid

    Directory of Open Access Journals (Sweden)

    B. Klenow

    2010-01-01

    Full Text Available Cavitation effects play an important role in the UNDEX loading of a structure. For far-field UNDEX, the structural loading is affected by the formation of local and bulk cavitation regions, and the pressure pulses resulting from the closure of the cavitation regions. A common approach to numerically modeling cavitation in far-field underwater explosions is Cavitating Acoustic Finite Elements (CAFE and more recently Cavitating Acoustic Spectral Elements (CASE. Treatment of cavitation in this manner causes spurious pressure oscillations which must be treated by a numerical damping scheme. The focus of this paper is to investigate the severity of these oscillations on the structural response and a possible improvement to CAFE, based on the original Boris and Book Flux-Corrected Transport algorithm on structured meshes [6], to limit oscillations without the energy loss associated with the current damping schemes.

  15. A review of recent theoretical investigations on acoustic cavitation bubbles and their implications on detection of cavitation in pumps

    Science.gov (United States)

    Zhang, Y. N.

    2013-12-01

    Detection of cavitation in pumps is one of the essential topics in hydraulic machinery research and has been intensively investigated for several decades. In the literature, a technique based on analysis of acoustic signals generated by cavitation bubbles in the pumps has been proposed to detect cavitation activities especially incipient cavitation. In present paper, recent theoretical investigations by the author and his collaborators on acoustic cavitation bubbles (e.g. damping mechanisms, heat and mass transfer) together with their associated acoustical signals have been briefly reviewed to advance above technique.

  16. Sustained Attention Development during the Toddlerhood to Preschool Period: Associations with Toddlers' Emotion Regulation Strategies and Maternal Behaviour

    Science.gov (United States)

    Graziano, Paulo A.; Calkins, Susan D.; Keane, Susan P.

    2011-01-01

    The current study examined the role of maternal behaviour and toddlers' emotion regulation strategies in the development of children's sustained attention abilities. Participants for this study included 447 children (232 girls) obtained from three different cohorts participating in a larger ongoing longitudinal study. When the children were 2…

  17. Diagnostic ultrasound induced inertial cavitation to non-invasively restore coronary and microvascular flow in acute myocardial infarction.

    Science.gov (United States)

    Xie, Feng; Gao, Shunji; Wu, Juefei; Lof, John; Radio, Stanley; Vignon, Francois; Shi, William; Powers, Jeffry; Unger, Evan; Everbach, E Carr; Liu, Jinjin; Porter, Thomas R

    2013-01-01

    Ultrasound induced cavitation has been explored as a method of dissolving intravascular and microvascular thrombi in acute myocardial infarction. The purpose of this study was to determine the type of cavitation required for success, and whether longer pulse duration therapeutic impulses (sustaining the duration of cavitation) could restore both microvascular and epicardial flow with this technique. Accordingly, in 36 hyperlipidemic atherosclerotic pigs, thrombotic occlusions were induced in the mid-left anterior descending artery. Pigs were then randomized to either a) ½ dose tissue plasminogen activator (0.5 mg/kg) alone; or same dose plasminogen activator and an intravenous microbubble infusion with either b) guided high mechanical index short pulse (2.0 MI; 5 usec) therapeutic ultrasound impulses; or c) guided 1.0 mechanical index long pulse (20 usec) impulses. Passive cavitation detectors indicated the high mechanical index impulses (both long and short pulse duration) induced inertial cavitation within the microvasculature. Epicardial recanalization rates following randomized treatments were highest in pigs treated with the long pulse duration therapeutic impulses (83% versus 59% for short pulse, and 49% for tissue plasminogen activator alone; pepicardial recanalization, however, early microvascular recovery occurred with both short and long pulse therapeutic impulses (pepicardial and microvascular re-flow in acute myocardial infarction.

  18. Diagnosing non-cavitated lesions in epidemiological studies: practical and scientific considerations

    Directory of Open Access Journals (Sweden)

    Joana Christina Carvalho

    2014-01-01

    Full Text Available Over the last decade, there has been growing interest in diagnosing non-cavitated lesions in epidemiological studies involving large numbers of preschool children, schoolchildren and young adults. In this context, assessment of lesions characteristics indicating whether or not there is ongoing mineral loss is also considered relevant. The reasoning sustained by these studies is that diagnosis of the caries process limited to the cavitated level is no longer in accordance with current state-of-the-art knowledge in cariology. This paper highlights one topic of the lecture entitled "Caries Process: Evolving Evidence and Understanding," presented at the 18th Congress of the Brazilian Association for Oral Health Promotion (Associação Brasileira de Odontologia de Promoção de Saúde - ABOPREV in April 2013. In the framework of epidemiological studies, the interest in diagnosing active and inactive non-cavitated lesions was elucidated. However, relevant questions associated with the diagnosis of non-cavitated lesions that might raise concerns among researchers and health administrators were not addressed. The present paper aims to bring these questions into discussion. The contribution of this discussion in terms of developing the understanding of caries decline is analyzed by using data from a caries trends study of Brazilian preschool children residing in the Federal District of Brazil as an example. The inclusion of active and inactive non-cavitated lesions in the diagnosis of the caries process allowed us to demonstrate that, in Brazilian 1- to 5-year-old children, caries prevalence decreased significantly from 1996 to 2006, simultaneously with a reduction in the rate of caries progression.

  19. Diagnosing non-cavitated lesions in epidemiological studies: practical and scientific considerations.

    Science.gov (United States)

    Carvalho, Joana Christina; Mestrinho, Heliana Dantas

    2014-01-01

    Over the last decade, there has been growing interest in diagnosing non-cavitated lesions in epidemiological studies involving large numbers of preschool children, schoolchildren and young adults. In this context, assessment of lesions characteristics indicating whether or not there is ongoing mineral loss is also considered relevant. The reasoning sustained by these studies is that diagnosis of the caries process limited to the cavitated level is no longer in accordance with current state-of-the-art knowledge in cariology. This paper highlights one topic of the lecture entitled "Caries Process: Evolving Evidence and Understanding," presented at the 18th Congress of the Brazilian Association for Oral Health Promotion (Associação Brasileira de Odontologia de Promoção de Saúde - ABOPREV) in April 2013. In the framework of epidemiological studies, the interest in diagnosing active and inactive non-cavitated lesions was elucidated. However, relevant questions associated with the diagnosis of non-cavitated lesions that might raise concerns among researchers and health administrators were not addressed. The present paper aims to bring these questions into discussion. The contribution of this discussion in terms of developing the understanding of caries decline is analyzed by using data from a caries trends study of Brazilian preschool children residing in the Federal District of Brazil as an example. The inclusion of active and inactive non-cavitated lesions in the diagnosis of the caries process allowed us to demonstrate that, in Brazilian 1- to 5-year-old children, caries prevalence decreased significantly from 1996 to 2006, simultaneously with a reduction in the rate of caries progression.

  20. Film temperatures in the presence of cavitation

    Science.gov (United States)

    Elrod, Harold G.; Vijayaraghavan, D.

    1995-01-01

    Numerical algorithms are developed and implemented for the treatment of laminar lubricating-film temperatures associated with cavitated regions. The reformation front, with its film-content discontinuity and flow reversal, is given special attention. Computational economy is achieved through the use of Lobatto-point locations for flow-property determinations.

  1. Classification of lubricants according to cavitation criteria

    NARCIS (Netherlands)

    Meged, Y.; Meged, Y.; Venner, Cornelis H.; ten Napel, W.E.

    1995-01-01

    Cavitation in lubrication liquids has long been known to be detrimental to components in hydraulic systems. Damage has been detected in journal bearings, especially under severe dynamic loading, gears, squeeze film dampers and valves. These findings have led to intensive studies of metal resistance

  2. Control of Propeller Cavitation in Operational Conditions

    NARCIS (Netherlands)

    Vrijdag, A.

    2009-01-01

    Off design conditions can have a severe impact on ship propulsion system behaviour. Resistance increase for instance leads to a higher engine loading, and can also easily lead to a decrease of cavitation inception speed with respect to calm water conditions. Wakefield variations due to ship motions,

  3. Modelling cavitating flow around underwater missiles

    Directory of Open Access Journals (Sweden)

    Fabien Petitpas

    2011-12-01

    Full Text Available The diffuse interface model of Saurel et al. (2008 is used for the computation of compressible cavitating flows around underwater missiles. Such systems use gas injection and natural cavitation to reduce drag effects. Consequently material interfaces appear separating liquid and gas. These interfaces may have a really complex dynamics such that only a few formulations are able to predict their evolution. Contrarily to front tracking or interface reconstruction method the interfaces are computed as diffused numerical zones, that are captured in a routinely manner, as is done usually with gas dynamics solvers for shocks and contact discontinuity. With the present approach, a single set of partial differential equations is solved everywhere, with a single numerical scheme. This leads to very efficient solvers. The algorithm derived in Saurel et al. (2009 is used to compute cavitation pockets around solid bodies. It is first validated against experiments done in cavitation tunnel at CNU. Then it is used to compute flows around high speed underwater systems (Shkval-like missile. Performance data are then computed showing method ability to predict forces acting on the system.

  4. Mesoscale spatial variability in seawater cavitation thresholds

    Science.gov (United States)

    Mel'nikov, N. P.; Elistratov, V. P.

    2017-03-01

    The paper presents the spatial variability of cavitation thresholds and some hydrological and hydrochemical parameters of seawater in the interfrontal zone of the Pacific Subarctic Front, in the Drake Passage, and in the equatorial part of the Pacific Ocean, measured in the near-surface layer to a depth of 70 m.

  5. Relating xylem cavitation to transpiration in cotton

    Science.gov (United States)

    Acoustic emmisions (AEs) from xylem cavitation events are characteristic of transpiration processes. Even though a body of work employing AE exists with a large number of species, cotton and other agronomically important crops have either not been investigated, or limited information exists. A few s...

  6. Measuring cavitation and its cleaning effect

    NARCIS (Netherlands)

    Verhaagen, B.; Fernandez Rivas, David

    2016-01-01

    The advantages and limitations of techniques for measuring the presence and amount of cavitation, and for quantifying the removal of contaminants, are provided. After reviewing chemical, physical, and biological studies, a universal cause for the cleaning effects of bubbles cannot yet be concluded.

  7. Flow field measurement around vortex cavitation

    NARCIS (Netherlands)

    Pennings, P.C.; Westerweel, J.; Van Terwisga, T.J.C.

    2015-01-01

    Models for the center frequency of cavitating-vortex induced pressure-fluctuations, in a flow around propellers, require knowledge of the vortex strength and vapor cavity size. For this purpose, stereoscopic particle image velocimetry (PIV) measurements were taken downstream of a fixed half-wing

  8. Mechanisms of thrombolysis acceleration by cavitation

    Science.gov (United States)

    Weiss, Hope; Selvaraj, Prashanth; Ahadi, Golnaz; Voie, Arne; Hoelscher, Thilo; Okita, Kohei; Matsumoto, Yoichiro; Szeri, Andrew

    2012-11-01

    Recent studies, in vitro and in vivo, have shown that High Intensity Focused Ultrasound (HIFU) accelerates thrombolysis, the dissolution of blood clots, for ischemic stroke. Although the mechanisms are not fully understood, cavitation is thought to play an important role in sonothrombolysis. The damage to a blood clot's fibrin fiber network from cavitation in a HIFU field is studied using two independent approaches for an embedded bubble. One method is extended to the more important scenario of a bubble outside a blood clot that collapses asymmetrically creating a jet towards the clot. There is significantly more damage potential from a bubble undergoing cavitation collapse outside the clot compared to a rapidly expanding bubble embedded within the clot structure. Also, the effects of the physical properties of skull bone when a HIFU wave propagates through it are examined by use of computer simulation. The dynamics of a test bubble placed at the focus is used in understanding of the pressure field. All other things being equal, the analysis suggests that skull thickness can alter the wave at the focus, which in turn can change the nature of cavitation bubble dynamics and the amount of energy available for clot damage. Now at MSOE.

  9. Inertial cavitation threshold of nested microbubbles.

    Science.gov (United States)

    Wallace, N; Dicker, S; Lewin, Peter; Wrenn, S P

    2015-04-01

    Cavitation of ultrasound contrast agents (UCAs) promotes both beneficial and detrimental bioeffects in vivo (Radhakrishnan et al., 2013) [1]. The ability to determine the inertial cavitation threshold of UCA microbubbles has potential application in contrast imaging, development of therapeutic agents, and evaluation of localized effects on the body (Ammi et al., 2006) [2]. This study evaluates a novel UCA and its inertial cavitation behavior as determined by a home built cavitation detection system. Two 2.25 MHz transducers are placed at a 90° angle to one another where one transducer is driven by a high voltage pulser and the other transducer receives the signal from the oscillating microbubble. The sample chamber is placed in the overlap of the focal region of the two transducers where the microbubbles are exposed to a pulser signal consisting of 600 pulse trains per experiment at a pulse repetition frequency of 5 Hz where each train has four pulses of four cycles. The formulation being analyzed is comprised of an SF6 microbubble coated by a DSPC PEG-3000 monolayer nested within a poly-lactic acid (PLA) spherical shell. The effect of varying shell diameters and microbubble concentration on cavitation threshold profile for peak negative pressures ranging from 50 kPa to 2 MPa are presented and discussed in this paper. The nesting shell decreases inertial cavitation events from 97.96% for an un-nested microbubble to 19.09% for the same microbubbles nested within a 2.53 μm shell. As shell diameter decreases, the percentage of inertially cavitating microbubbles also decreases. For nesting formulations with average outer capsule diameters of 20.52, 14.95, 9.95, 5.55, 2.53, and 1.95 μm, the percentage of sample destroyed at 1 MPa was 51.02, 38.94, 33.25, 25.27, 19.09, and 5.37% respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. An experimental investigation of acoustic cavitation in gaseous liquids

    Science.gov (United States)

    Gaitan, Dario F.; Crum, Lawrence A.

    1990-11-01

    High amplitude radial pulsations of a single bubble in several glycerine and water mixtures were observed in an acoustic stationary wave system at acoustic pressure amplitudes on the order of 150 kPa at 21 to 25 kHz. Sonoluminescence, a phenomenon generally attributed to the high temperatures generated during the collapse of cavitation bubbles, was observed as short light pulses occurring once every acoustic period. These emissions could be seen to originate at the geometric center of the bubble when observed through a microscope. It was observed that the light emissions occurred simultaneously with the bubble collapse. Using a laser scattering technique, experimental radius-time curves were obtained which confirmed the absence of surface waves which are expected at pressure amplitudes above 100 kPa. From these radius-time curves, measurements of the pulsation amplitude, the timing of the major bubble collapse, and the number of rebounds were made and compared with several theories. The implications of this research on the current understanding of cavitation were discussed.

  11. Stability of cavitation structures in a thin liquid layer.

    Science.gov (United States)

    Wu, Pengfei; Bai, Lixin; Lin, Weijun; Yan, Jiuchun

    2017-09-01

    The inception and evolution of acoustic cavitation structures in thin liquid layers under different conditions and perturbations are investigated experimentally with high speed photography. The stability and characterization of cavitation structures are quantified by image analysis methods. It is found that cavitation structures (shape of bubble cloud and number of bubbles) are stable under unaltered experimental conditions, and the cavitation bubble cloud will return to the original structure and remain stable even in the face of large perturbations. When the experimental conditions are altered (for example, acoustic intensity, cavitation nuclei, boundary), the cavitation structures will vary correspondingly. Further analysis implies that the stability of cavitation structures is closely related to the number of bubbles in the cavitation bubble cloud. There are two mechanisms acting simultaneously in the cavitation bubble cloud evolution, one "bubble production" and the other "bubble disappearance". We propose that the two mechanisms acting together constitute the most likely explanation for the stability of cavitation structures and their transformation. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Treatment of cyanide containing wastewater using cavitation based approach.

    Science.gov (United States)

    Jawale, Rajashree H; Gogate, Parag R; Pandit, Aniruddha B

    2014-07-01

    Industrial wastewater streams containing high concentrations of biorefractory materials like cyanides should ideally be treated at source. In the present work, degradation of potassium ferrocyanide (K4Fe(CN)6) as a model pollutant has been investigated using cavitational reactors with possible intensification studies using different approaches. Effect of different operating parameters such as initial concentration, temperature and pH on the extent of degradation using acoustic cavitation has been investigated. For the case of hydrodynamic cavitation, flow characteristics of cavitating device (venturi) have been established initially followed by the effect of inlet pressure and pH on the extent of degradation. Under the optimized set of operating parameters, the addition of hydrogen peroxide (ratio of K4Fe(CN)6:H2O2 varied from 1:1 to 1:30 mol basis) as process intensifying approach has been investigated. The present work has conclusively established that under the set of optimized operating parameters, cavitation can be effectively used for degradation of potassium ferrocyanide. The comparative study of hydrodynamic cavitation and acoustic cavitation suggested that hydrodynamic cavitation is more energy efficient and gives higher degradation as compared to acoustic cavitation for equivalent power/energy dissipation. The present work is the first one to report comparison of cavitation based treatment schemes for degradation of cyanide containing wastewaters. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Cavitation and non-cavitation regime for large-scale ultrasonic standing wave particle separation systems--In situ gentle cavitation threshold determination and free radical related oxidation.

    Science.gov (United States)

    Johansson, Linda; Singh, Tanoj; Leong, Thomas; Mawson, Raymond; McArthur, Sally; Manasseh, Richard; Juliano, Pablo

    2016-01-01

    We here suggest a novel and straightforward approach for liter-scale ultrasound particle manipulation standing wave systems to guide system design in terms of frequency and acoustic power for operating in either cavitation or non-cavitation regimes for ultrasound standing wave systems, using the sonochemiluminescent chemical luminol. We show that this method offers a simple way of in situ determination of the cavitation threshold for selected separation vessel geometry. Since the pressure field is system specific the cavitation threshold is system specific (for the threshold parameter range). In this study we discuss cavitation effects and also measure one implication of cavitation for the application of milk fat separation, the degree of milk fat lipid oxidation by headspace volatile measurements. For the evaluated vessel, 2 MHz as opposed to 1 MHz operation enabled operation in non-cavitation or low cavitation conditions as measured by the luminol intensity threshold method. In all cases the lipid oxidation derived volatiles were below the human sensory detection level. Ultrasound treatment did not significantly influence the oxidative changes in milk for either 1 MHz (dose of 46 kJ/L and 464 kJ/L) or 2 MHz (dose of 37 kJ/L and 373 kJ/L) operation. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Hydrodynamic cavitation in Stokes flow of anisotropic fluids

    Science.gov (United States)

    Stieger, Tillmann; Agha, Hakam; Schoen, Martin; Mazza, Marco G.; Sengupta, Anupam

    2017-01-01

    Cavitation, the nucleation of vapour in liquids, is ubiquitous in fluid dynamics, and is often implicated in a myriad of industrial and biomedical applications. Although extensively studied in isotropic liquids, corresponding investigations in anisotropic liquids are largely lacking. Here, by combining liquid crystal microfluidic experiments, nonequilibrium molecular dynamics simulations and theoretical arguments, we report flow-induced cavitation in an anisotropic fluid. The cavitation domain nucleates due to sudden pressure drop upon flow past a cylindrical obstacle within a microchannel. For an anisotropic fluid, the inception and growth of the cavitation domain ensued in the Stokes regime, while no cavitation was observed in isotropic liquids flowing under similar hydrodynamic parameters. Using simulations we identify a critical value of the Reynolds number for cavitation inception that scales inversely with the order parameter of the fluid. Strikingly, the critical Reynolds number for anisotropic fluids can be 50% lower than that of isotropic fluids. PMID:28555615

  15. Hull-Propeller Interaction and Its Effect on Propeller Cavitation

    DEFF Research Database (Denmark)

    Regener, Pelle Bo

    , which presumably does not reflect the differences between the propellers sufficiently. Obtaining effective wake fields using the hybrid RANS-BEM approach at model and full scale also provides the opportunity to investigate the behind-ship cavitation performance of propellers with comparably low...... computational effort. The boundary element method for propeller analysis includes a partially nonlinear cavitation model, which is able to predict partial sheet cavitation and supercavitation. The cavitation behaviour of the conventional propeller and the Kappel propeller from the earlier simulations...... a major effect on propeller cavitation, signifying the importance of using the correct inflow, i.e. the effective wake field when evaluating propeller cavitation performance....

  16. Cavitation measurement during sonic and ultrasonic activated irrigation.

    Science.gov (United States)

    Macedo, Ricardo; Verhaagen, Bram; Rivas, David Fernandez; Versluis, Michel; Wesselink, Paul; van der Sluis, Luc

    2014-04-01

    The aims of this study were to quantify and to visualize the possible occurrence of transient cavitation (bubble formation and implosion) during sonic and ultrasonic (UAI) activated irrigation. The amount of cavitation generated around several endodontic instruments was measured by sonochemiluminescence dosimetry inside 4 root canal models of human dimensions and varying complexity. Furthermore, the spatial distribution of the sonochemiluminescence in the root canal was visualized with long-exposure photography. Instrument oscillation frequency, ultrasonic power, and file taper influenced the occurrence and amount of cavitation. In UAI, cavitation was distributed between the file and the wall extending beyond the file and inside lateral canals/isthmuses. In sonic activated irrigation, no cavitation was detected. Cavitation was shown to occur in UAI at clinically relevant ultrasonic power settings in both straight and curved canals but not around sonically oscillating instruments, driven at their highest frequency. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Simulations of Steady Cavitating Flow in a Small Francis Turbine

    Directory of Open Access Journals (Sweden)

    Ahmed Laouari

    2016-01-01

    Full Text Available The turbulent flow through a small horizontal Francis turbine is solved by means of Ansys-CFX at different operating points, with the determination of the hydrodynamic performance and the best efficiency point. The flow structures at different regimes reveal a large flow eddy in the runner and a swirl in the draft tube. The use of the mixture model for the cavity/liquid two-phase flow allowed studying the influence of cavitation on the hydrodynamic performance and revealed cavitation pockets near the trailing edge of the runner and a cavitation vortex rope in the draft tube. By maintaining a constant dimensionless head and a distributor vane opening while gradually increasing the cavitation number, the output power and efficiency reached a critical point and then had begun to stabilize. The cavitation number corresponding to the safety margin of cavitation is also predicted for this hydraulic turbine.

  18. Technical note: measurement of collapse cavitation in ultrasound fields.

    Science.gov (United States)

    Digby, M; Duck, F A; Lenz, E J; Price, G J

    1995-11-01

    This note describes a method for the measurement of hydroxyl free radical concentration due to collapse acoustic cavitation in medical ultrasound fields using aqueous terephthalic acid (TA) solution. An enclosed cylindrical chamber with acoustically transparent membranes at either end was used. Control of cavitation activity was achieved by seeding the solution with polystyrene microspheres to provide cavitation centres. Insonation experiments using unseeded TA previously exposed to air gave very variable results, sometimes detecting cavitation activity and at other times detecting nothing, under the same exposure conditions. Introduction of polystyrene microsphere seeds into the TA enabled it to detect reproducibly levels of cavitation activity at least one order of magnitude higher than in unseeded solutions. An experiment using the seeded TA in a standing wave ultrasound field, set up using a brass reflecting plate, demonstrated that the presence of a standing wave inhibited the measured cavitation yield.

  19. Numerical study of ventilated cavitating flows with free surface effects

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Mei Shan; Ha, Cong Tu; Park, Warn Gyu [Pusan National University, Busan (Korea, Republic of)

    2013-12-15

    Cavitating flow is usually formed on the surface of a high-speed underwater object. When the object moves near the free surface at high speed, the cavitation signature becomes a main factor to be overcome by the sensors of a military satellite. This paper studies the free surface effect on the ventilated cavitation process. The governing equations are Navier-Stokes equations based on a homogeneous mixture model. The multiphase flow solver used here relies on an implicit preconditioning scheme in curvilinear coordinates. The cavitation model used is a new cavitation model developed by Merkle et al. (2006). Computations of free surface effects were carried out with a NACA0012 hydrofoil to enable comparisons with experimental data presented in the literature. Calculations were then performed considering the ventilated cavitation process, including the effect of a noncondensable gas with free surface effect.

  20. Regulating Ultrasound Cavitation in order to Induce Reproducible Sonoporation

    Science.gov (United States)

    Mestas, J.-L.; Alberti, L.; El Maalouf, J.; Béra, J.-C.; Gilles, B.

    2010-03-01

    Sonoporation would be linked to cavitation, which generally appears to be a non reproducible and unstationary phenomenon. In order to obtain an acceptable trade-off between cell mortality and transfection, a regulated cavitation generator based on an acoustical cavitation measurement was developed and tested. The medium to be sonicated is placed in a sample tray. This tray is immersed in in degassed water and positioned above the face of a flat ultrasonic transducer (frequency: 445 kHz; intensity range: 0.08-1.09 W/cm2). This technical configuration was admitted to be conducive to standing-wave generation through reflection at the air/medium interface in the well thus enhancing the cavitation phenomenon. Laterally to the transducer, a homemade hydrophone was oriented to receive the acoustical signal from the bubbles. From this spectral signal recorded at intervals of 5 ms, a cavitation index was calculated as the mean of the cavitation spectrum integration in a logarithmic scale, and the excitation power is automatically corrected. The device generates stable and reproducible cavitation level for a wide range of cavitation setpoint from stable cavitation condition up to full-developed inertial cavitation. For the ultrasound intensity range used, the time delay of the response is lower than 200 ms. The cavitation regulation device was evaluated in terms of chemical bubble collapse effect. Hydroxyl radical production was measured on terephthalic acid solutions. In open loop, the results present a great variability whatever the excitation power. On the contrary the closed loop allows a great reproducibility. This device was implemented for study of sonodynamic effect. The regulation provides more reproducible results independent of cell medium and experimental conditions (temperature, pressure). Other applications of this regulated cavitation device concern internalization of different particles (Quantum Dot) molecules (SiRNA) or plasmids (GFP, DsRed) into different

  1. Cavitation-based hydro-fracturing simulator

    Science.gov (United States)

    Wang, Jy-An John; Wang, Hong; Ren, Fei; Cox, Thomas S.

    2016-11-22

    An apparatus 300 for simulating a pulsed pressure induced cavitation technique (PPCT) from a pressurized working fluid (F) provides laboratory research and development for enhanced geothermal systems (EGS), oil, and gas wells. A pump 304 is configured to deliver a pressurized working fluid (F) to a control valve 306, which produces a pulsed pressure wave in a test chamber 308. The pulsed pressure wave parameters are defined by the pump 304 pressure and control valve 306 cycle rate. When a working fluid (F) and a rock specimen 312 are included in the apparatus, the pulsed pressure wave causes cavitation to occur at the surface of the specimen 312, thus initiating an extensive network of fracturing surfaces and micro fissures, which are examined by researchers.

  2. Cavitation-Resistant Coatings for Hydropower Turbines

    Science.gov (United States)

    2011-06-01

    powders , plasma transferred arc powders , and metallizing wire Scott Ostholthoff Does not currently have any products tested to ASTM G32; though they...anti-cavitation and surface hardening coatings. Vendor Product(s) Contact Notes Powder Alloy Inc. Thermal coatings, HVOF powders , plasma spray...provide the weld rod and powder materials. Interested in our research and willing to provide support on tools. They noted new HVOF system, JP5000

  3. Interspecific variation in xylem vulnerability to cavitation among tropical tree and shrub species.

    Science.gov (United States)

    Lopez, Omar R; Kursar, Thomas A; Cochard, Hervé; Tyree, Melvin T

    2005-12-01

    In tropical moist forests, seasonal drought limits plant survival, productivity and diversity. Drought-tolerance mechanisms of tropical species should reflect the maximum seasonal water deficits experienced in a particular habitat. We investigated stem xylem vulnerability to cavitation in nine tropical species with different life histories and habitat associations. Stem xylem vulnerability was scored as the xylem water potential causing 50 and 75% loss of hydraulic conductivity (P50 and P75, respectively). Four shade-tolerant shrubs ranged from moderately resistant (P50=-1.9 MPa for Ouratea lucens Kunth. Engl.) to highly resistant to cavitation (P50=-4.1 MPa for Psychotria horizontalis Sw.), with shallow-rooted species being the most resistant. Among the tree species, those characteristic of waterlogged soils, Carapa guianensis Aubl., Prioria copaifera Griseb. and Ficus citrifolia Mill., were the most vulnerable to cavitation (P50=-0.8 to -1.6 MPa). The wet-season, deciduous tree, Cordia alliodora (Ruiz and Pav.) Oken., had resistant xylem (P50=-3.2 MPa), whereas the dry-season, deciduous tree, Bursera simaruba (L.) Sarg. was among the most vulnerable to cavitation (P50=-0.8 MPa) of the species studied. For eight out of the nine study species, previously reported minimum seasonal leaf water potentials measured in the field during periods of drought correlated with our P50 and P75 values. Rooting depth, deciduousness, soil type and growth habit might also contribute to desiccation tolerance. Our results support the functional dependence of drought tolerance on xylem resistance to cavitation.

  4. Are flowers vulnerable to xylem cavitation during drought?

    Science.gov (United States)

    Zhang, Feng-Ping; Brodribb, Timothy J

    2017-05-17

    Water stress is known to cause xylem cavitation in the leaves, roots and stems of plants, but little is known about the vulnerability of flowers to xylem damage during drought. This is an important gap in our understanding of how and when plants become damaged by water stress. Here we address fundamental questions about if and when flowers suffer cavitation damage, using a new technique of cavitation imaging to resolve the timing of cavitation in water-stressed flower petals compared with neighbouring leaves. Leaves and flowers from a sample of two herbaceous and two woody eudicots were exposed to a severe water stress while the spatial and temporal propagation of embolism through veins was recorded. Although in most cases water potentials inducing 50% embolism of herbaceous flower veins were more negative than neighbouring leaves, there was no significant difference between the average vulnerability of leaves and petals of herbaceous species. In both woody species, petals were more vulnerable to cavitation than leaves, in one case by more than 3 MPa. Early cavitation and subsequent damage of flowers in the two woody species would thus be expected to precede leaf damage during drought. Similar cavitation thresholds of flowers and leaves in the herb sample suggest that cavitation during water shortage in these species will occur simultaneously among aerial tissues. Species-specific differences in the cavitation thresholds of petals provide a new axis of variation that may explain contrasting flowering ecology among plant species. © 2017 The Author(s).

  5. High Speed Imaging of Cavitation around Dental Ultrasonic Scaler Tips.

    Science.gov (United States)

    Vyas, Nina; Pecheva, Emilia; Dehghani, Hamid; Sammons, Rachel L; Wang, Qianxi X; Leppinen, David M; Walmsley, A Damien

    2016-01-01

    Cavitation occurs around dental ultrasonic scalers, which are used clinically for removing dental biofilm and calculus. However it is not known if this contributes to the cleaning process. Characterisation of the cavitation around ultrasonic scalers will assist in assessing its contribution and in developing new clinical devices for removing biofilm with cavitation. The aim is to use high speed camera imaging to quantify cavitation patterns around an ultrasonic scaler. A Satelec ultrasonic scaler operating at 29 kHz with three different shaped tips has been studied at medium and high operating power using high speed imaging at 15,000, 90,000 and 250,000 frames per second. The tip displacement has been recorded using scanning laser vibrometry. Cavitation occurs at the free end of the tip and increases with power while the area and width of the cavitation cloud varies for different shaped tips. The cavitation starts at the antinodes, with little or no cavitation at the node. High speed image sequences combined with scanning laser vibrometry show individual microbubbles imploding and bubble clouds lifting and moving away from the ultrasonic scaler tip, with larger tip displacement causing more cavitation.

  6. Experimental Investigation of Cavitation Induced Feedline Instability from an Orifice

    Science.gov (United States)

    Hitt, Matthew A.; Lineberry, David M.; Ahuja, Vineet; Frederick, Robert A,

    2012-01-01

    This paper details the results of an experimental investigation into the cavitation instabilities created by a circular orifice conducted at the University of Alabama in Huntsville Propulsion Research Center. This experiment was conducted in concert with a computational simulation to serve as a reference point for the simulation. Testing was conducted using liquid nitrogen as a cryogenic propellant simulant. A 1.06 cm diameter thin orifice with a rounded inlet was tested in an approximately 1.25 kg/s flow with inlet pressures ranging from 504.1 kPa to 829.3 kPa. Pressure fluctuations generated by the orifice were measured using a high frequency pressure sensor located 0.64 tube diameters downstream of the orifice. Fast Fourier Transforms were performed on the high frequency data to determine the instability frequency. Shedding resulted in a primary frequency with a cavitation related subharmonic frequency. For this experiment, the cavitation instability ranged from 153 Hz to 275 Hz. Additionally, the strength of the cavitation occur red as a function of cavitation number. At lower cavitation numbers, the strength of the cavitation instability ranged from 2.4 % to 7 % of the inlet pressure. However, at higher cavitation numbers, the strength of the cavitation instability ranged from 0.6 % to 1 % of the inlet pressure.

  7. Cavitation Erosion of Nodular Cast Iron − Microstructural Effects

    Directory of Open Access Journals (Sweden)

    Orłowicz A.W.

    2017-12-01

    Full Text Available The paper deals with susceptibility of nodular cast iron with ferritic-pearlitic matrix on cavitation erosion. Cavitation tests were carried out with the use of a cavitation erosion vibratory apparatus employing a vibration exciter operated at frequency of 20 kHz. The study allowed to determine the sequence of subsequent stages in which microstructure of cast iron in superficial regions is subject to degradation. The first features to be damaged are graphite precipitates. The ferritic matrix of the alloy turned out to be definitely less resistant to cavitation erosion compared to the pearlitic matrix component.

  8. Cavitation Inception on Microparticles: A Self-Propelled Particle Accelerator

    DEFF Research Database (Denmark)

    Arora, M.; Ohl, C.-D.; Mørch, Knud Aage

    2004-01-01

    Corrugated, hydrophilic particles with diameters between 30 and 150 mum are found to cause cavitation inception at their surfaces when they are exposed to a short, intensive tensile stress wave. The growing cavity accelerates the particle into translatory motion until the tensile stress decreases......, and subsequently the particle separates from the cavity. The cavity growth and particle detachment are modeled by considering the momentum of the particle and the displaced liquid. The analysis suggests that all particles which cause cavitation are accelerated into translatory motion, and separate from...... the cavities they themselves nucleate. Thus, in the research of cavitation nuclei the link is established between developed cavitation bubbles and their origin....

  9. Photoacoustic cavitation for theranostics: mechanism, current progress and applications

    Science.gov (United States)

    Feng, Y.; Qin, D.; Wan, M.

    2015-12-01

    As an emerging cavitation technology, photoacoustic cavitation (PAC) means the formation of bubbles in liquids using focused laser and pre-established ultrasound synchronously. Its significant advantages include the decreased threshold of each modality and the precise location of cavitation determined by the focused laser. In this paper, a brief review of PAC is presented, including the physical mechanism description, the classic experimental technology, the representative results in variety of media, and its applications in biomedical imaging and therapy. Moreover, some preliminary results of PAC in perfluoropentane (PFP) liquid and PFP droplets investigated by passive cavitation detection (PCD) in our group are also presented.

  10. Calcium Is a Major Determinant of Xylem Vulnerability to Cavitation

    Science.gov (United States)

    Herbette, Stephane; Cochard, Herve

    2010-01-01

    Xylem vulnerability to cavitation is a key parameter in the drought tolerance of trees, but little is known about the control mechanisms involved. Cavitation is thought to occur when an air bubble penetrates through a pit wall, and would hence be influenced by the wall's porosity. We first tested the role of wall-bound calcium in vulnerability to cavitation in Fagus sylvatica. Stems perfused with solutions of oxalic acid, EGTA, or sodium phosphate (NaPO4) were found to be more vulnerable to cavitation. The NaPO4-induced increase in vulnerability to cavitation was linked to calcium removal from the wall. In contrast, xylem hydraulic conductance was unaffected by the chemical treatments, demonstrating that the mechanisms controlling vulnerability to cavitation and hydraulic resistance are uncoupled. The NaPO4 solution was then perfused into stems from 13 tree species possessing highly contrasted vulnerability to cavitation. Calcium was found to be a major determinant of between-species differences in vulnerability to cavitation. This was evidenced in angiosperms as well as conifer species, thus supporting the hypothesis of a common mechanism in drought-induced cavitation. PMID:20547703

  11. Computational fluid dynamic modelling of cavitation

    Science.gov (United States)

    Deshpande, Manish; Feng, Jinzhang; Merkle, Charles L.

    1993-01-01

    Models in sheet cavitation in cryogenic fluids are developed for use in Euler and Navier-Stokes codes. The models are based upon earlier potential-flow models but enable the cavity inception point, length, and shape to be determined as part of the computation. In the present paper, numerical solutions are compared with experimental measurements for both pressure distribution and cavity length. Comparisons between models are also presented. The CFD model provides a relatively simple modification to an existing code to enable cavitation performance predictions to be included. The analysis also has the added ability of incorporating thermodynamic effects of cryogenic fluids into the analysis. Extensions of the current two-dimensional steady state analysis to three-dimensions and/or time-dependent flows are, in principle, straightforward although geometrical issues become more complicated. Linearized models, however offer promise of providing effective cavitation modeling in three-dimensions. This analysis presents good potential for improved understanding of many phenomena associated with cavity flows.

  12. Cavitating flow control through continuous tangential mass injection on a 2D hydrofoil at a small attack angle

    Directory of Open Access Journals (Sweden)

    Timoshevskiy Mikhail V.

    2016-01-01

    Full Text Available We studied cavitating flow over the suction side of a symmetric 2D foil – a scaled-down model of high-pressure hydroturbine guide vanes (GV – in different cavitation regimes at the attack angle of 3°. High-speed imaging was used to analyze spatial patterns and time dynamics of the gas-vapour cavities. A hydroacoustic pressure transducer was employed to register time-spectra of pressure fluctuations nearby the hydrofoil. A PIV technique was applied to measure the velocity fields and its fluctuations. The active flow control was implemented by means of a continuous liquid supply with different flow rates through a slot channel located in the GV surface. It was found that the active mass injection does not influence the primary flow upstream of the slot channel position. For the cavitation-free and cavitation inception cases, the injection was shown to make the turbulent wake past the GV section more intense. However, at the developed cavitation regimes the active flow management made it possible to reduce substantially the amplitude or even totally suppress the periodic cavity length oscillations and pressure pulsations associated with them.

  13. Modeling Unsteady Cavitation Effects and Dynamic Loads in Cryogenic Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — There currently are no analytical or CFD tools that can reliably predict unsteady cavitation dynamics in liquid rocket turbopumps. Cavitation effects, particularly...

  14. Ultrasonic cavitation erosion of 316L steel weld joint in liquid Pb-Bi eutectic alloy at 550°C.

    Science.gov (United States)

    Lei, Yucheng; Chang, Hongxia; Guo, Xiaokai; Li, Tianqing; Xiao, Longren

    2017-11-01

    Liquid lead-bismuth eutectic alloy (LBE) is applied in the Accelerator Driven transmutation System (ADS) as the high-power spallation neutron targets and coolant. A 19.2kHz ultrasonic device was deployed in liquid LBE at 550°C to induce short and long period cavitation erosion damage on the surface of weld joint, SEM and Atomic force microscopy (AFM) were used to map out the surface properties, and Energy Dispersive Spectrometer (EDS) was applied to the qualitative and quantitative analysis of elements in the micro region of the surface. The erosion mechanism for how the cavitation erosion evolved by studying the element changes, their morphology evolution, the surface hardness and the roughness evolution, was proposed. The results showed that the pits, caters and cracks appeared gradually on the erode surface after a period of cavitation. The surface roughness increased along with exposure time. Work hardening by the bubbles impact in the incubation stage strengthened the cavitation resistance efficiently. The dissolution and oxidation corrosion and cavitation erosion that simultaneously happened in liquid LBE accelerated corrosion-erosion process, and these two processes combined to cause more serious damage on the material surface. Contrast to the performance of weld metal, base metal exhibited a much better cavitation resistance. Copyright © 2017. Published by Elsevier B.V.

  15. Effects of Laser Shock Processing on Morphologies and Mechanical Properties of ANSI 304 Stainless Steel Weldments Subjected to Cavitation Erosion

    Science.gov (United States)

    Zhang, Lei; Lu, Jin-Zhong; Zhang, Yong-Kang; Ma, Hai-Le; Luo, Kai-Yu; Dai, Feng-Ze

    2017-01-01

    Effects of laser shock processing (LSP) on the cavitation erosion resistance of laser weldments were investigated by optical microscope (OM), scanning electron microscope (SEM) observations, roughness tester, micro hardness tester, and X-ray diffraction (XRD) technology. The morphological microstructures were characterized. Cumulative mass loss, incubation period, erosion rate, and damaged surface areas were monitored during cavitation erosion. Surface roughness, micro-hardness, and residual stress were measured in different zones. Results showed that LSP could improve the damage of morphological microstructures and mechanical properties after cavitation erosion. The compressive residual stresses were generated during the process of LSP, which was an effective guarantee for the improvement of the above mentioned properties. PMID:28772652

  16. Effects of Laser Shock Processing on Morphologies and Mechanical Properties of ANSI 304 Stainless Steel Weldments Subjected to Cavitation Erosion

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    2017-03-01

    Full Text Available Effects of laser shock processing (LSP on the cavitation erosion resistance of laser weldments were investigated by optical microscope (OM, scanning electron microscope (SEM observations, roughness tester, micro hardness tester, and X-ray diffraction (XRD technology. The morphological microstructures were characterized. Cumulative mass loss, incubation period, erosion rate, and damaged surface areas were monitored during cavitation erosion. Surface roughness, micro-hardness, and residual stress were measured in different zones. Results showed that LSP could improve the damage of morphological microstructures and mechanical properties after cavitation erosion. The compressive residual stresses were generated during the process of LSP, which was an effective guarantee for the improvement of the above mentioned properties.

  17. Assessment of Cavitation-Erosion Resistance of 316LN Stainless Steel Following a Nitro-Carburizing Surface Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, Steven J [ORNL

    2009-11-01

    A nitro-carburizing surface treatment known domestically as the Melonite process was applied to type 316LN stainless steel test pieces and exposed to sonication conditions in mercury using a vibratory horn technique. Cavitation-erosion damage was evaluated for extended exposures and compared to other surface treatments on the same substrate alloy. The results indicate that the Melonite process substantially retards weight loss and crater development for extended periods, but gradually is eroded/destroyed leading to exposure of the substrate and cavitation-erosion behavior similar to untreated specimens. Compared with other surface treatments, cavitation-erosion results indicate that specimens treated with Melonite perform similarly to specimens treated with a simple nitriding process. Neither the simple nitriding nor the Melonite treatment is quite as effective as a previously evaluated low temperature carburizing treatment, the latter being about a factor of three better than Melonite in terms of weight loss during sonication in mercury.

  18. Incubation pit analysis and calculation of the hydrodynamic impact pressure from the implosion of an acoustic cavitation bubble.

    Science.gov (United States)

    Tzanakis, I; Eskin, D G; Georgoulas, A; Fytanidis, D K

    2014-03-01

    An experimental study to evaluate cavitation bubble dynamics is conducted. The aim is to predict the magnitude and statistical distribution of hydrodynamic impact pressure generated from the implosion of various individual acoustic cavitation bubbles near to a rigid boundary, considering geometrical features of the pitted area. A steel sample was subjected to cavitation impacts by an ultrasonic transducer with a 5mm diameter probe. The pitted surface was then examined using high-precision 3D optical interferometer techniques. Only the incubation period where surface is plastically deformed without material loss is taken into account. The exposure time was adjusted in the range of 3-60 s to avoid pit overlapping and a special procedure for pit analysis and characterisation was then followed. Moreover, a high-speed camera device was deployed to capture the implosion mechanisms of cavitation bubbles near to the surface. The geometrical characteristics of single incubation pits as well as pit clusters were studied and their deformation patterns were compared. Consequently, a reverse engineering approach was applied in order the hydrodynamic impact pressure from the implosion of an individual cavitation bubble to be determined. The characteristic parameters of the cavitation implosion process such as hydrodynamic impact pressure and liquid micro-jet impact velocity as well as the hydrodynamic severity of the cavitation impacts were quantified. It was found that the length of the hypotenuse of the orthographic projections from the center of the pit, which basically represents the deformed area of the pit, increases with the hydrodynamic impact aggressiveness in a linear rate. Majority of the hydrodynamic impacts were in the range of 0.4-1 GPa while the corresponding micro-jet velocities were found to be in the range of 200-700 m/s. Outcomes of this study, contribute to further understanding the cavitation intensity from the implosion of acoustically generated bubbles and

  19. Diagnostic ultrasound induced inertial cavitation to non-invasively restore coronary and microvascular flow in acute myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Feng Xie

    Full Text Available Ultrasound induced cavitation has been explored as a method of dissolving intravascular and microvascular thrombi in acute myocardial infarction. The purpose of this study was to determine the type of cavitation required for success, and whether longer pulse duration therapeutic impulses (sustaining the duration of cavitation could restore both microvascular and epicardial flow with this technique. Accordingly, in 36 hyperlipidemic atherosclerotic pigs, thrombotic occlusions were induced in the mid-left anterior descending artery. Pigs were then randomized to either a ½ dose tissue plasminogen activator (0.5 mg/kg alone; or same dose plasminogen activator and an intravenous microbubble infusion with either b guided high mechanical index short pulse (2.0 MI; 5 usec therapeutic ultrasound impulses; or c guided 1.0 mechanical index long pulse (20 usec impulses. Passive cavitation detectors indicated the high mechanical index impulses (both long and short pulse duration induced inertial cavitation within the microvasculature. Epicardial recanalization rates following randomized treatments were highest in pigs treated with the long pulse duration therapeutic impulses (83% versus 59% for short pulse, and 49% for tissue plasminogen activator alone; p<0.05. Even without epicardial recanalization, however, early microvascular recovery occurred with both short and long pulse therapeutic impulses (p<0.005 compared to tissue plasminogen activator alone, and wall thickening improved within the risk area only in pigs treated with ultrasound and microbubbles. We conclude that although short pulse duration guided therapeutic impulses from a diagnostic transducer transiently improve microvascular flow, long pulse duration therapeutic impulses produce sustained epicardial and microvascular re-flow in acute myocardial infarction.

  20. Progressive development of water resources in the Middle East for sustainable water supply in a period of climate change.

    Science.gov (United States)

    Issar, Arie S; Adar, Eilon

    2010-11-28

    The history of the Middle East has been influenced by past global climatic changes. Warm periods caused droughts, resulting in desertification, migration and war. Cold periods were humid and brought prosperity and agricultural settlement to the desert fringes. The forecast based on this correlation is that the present global warming will cause the drying up of the Middle East. As in the past, this negative impact should be mitigated by using the groundwater resources stored from past wetter times. This will involve deep drilling, pumping and modern irrigation methods within the framework of a new policy of 'progressive development', which will entail the use of currently undeveloped natural water resources beyond that of present water replenishment. While the use of the one-time groundwater reserves is taking place, a master long-term comprehensive progressive development plan for the Middle East will be prepared. This plan will include the step-by-step development of other water resources such as treated effluents, desalinated brackish groundwater and desalination of seawater.

  1. Capability evaluation of ultrasonic cavitation peening at different standoff distances.

    Science.gov (United States)

    Bai, Fushi; Saalbach, Kai-Alexander; Long, Yangyang; Twiefel, Jens; Wallaschek, Jörg

    2018-03-01

    Ultrasonic cavitation peening is a novel surface treatment technology which utilizes the effect of cavitation bubble collapses to improve the properties of metal surfaces. In order to obtain high impact during ultrasonic cavitation peening, a small standoff distance between a sound radiator and a rigid reflector (the surface of treated specimen) is necessary. However, the effects of different standoff distances on the capability of ultrasonic cavitation peening are not yet clear. In this paper, a simplified model was developed to evaluate the cavitation capability at different standoff distances. Meanwhile, to validate the theoretical model, the plastic deformation or erosion on the peening surface before and after treatment were compared. It was found that at a very small standoff distance the impact pressure generated by cavitation bubbles did not cause much deformation or erosion, as the dynamics of cavitation bubbles was limited. At a large standoff distance, due to much attenuation of sound propagation in the bubbly liquid, little impact pressure was generated by the collapse of cavitation bubbles and reached the treated surface. A fixed vibration amplitude, however, corresponded to a standoff distance which caused the largest deformation or erosion on the treated surface. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Reproducible cavitation activity in water-particle suspensions

    NARCIS (Netherlands)

    Borkent, B.M.; Arora, M.; Ohl, C.D.

    2007-01-01

    The study of cavitation inception in liquids rarely yields reproducible data, unless special control is taken on the cleanliness of the experimental environment. In this paper, an experimental technique is demonstrated which allows repeatable measurements of cavitation activity in liquid-particle

  3. An objective comparison of commercially-available cavitation meters.

    Science.gov (United States)

    Sarno, Daniel; Hodnett, Mark; Wang, Lian; Zeqiri, Bajram

    2017-01-01

    With a number of cavitation meters on the market which claim to characterise fields in ultrasonic cleaning baths, this paper provides an objective comparison of a selection of these devices and establishes the extent to which their claims are met. The National Physical Laboratory's multi-frequency ultrasonic reference vessel provided the stable 21.06kHz field, above and below the inertial cavitation threshold, as a test bed for the sensor comparison. Measurements from these devices were evaluated in relation to the known acoustic pressure distribution in the cavitating vessel as a means of identifying the mode of operation of the sensors and to examine the particular indicator of cavitation activity which they deliver. Through the comparison with megahertz filtered acoustic signals generated by inertial cavitation, it was determined that the majority of the cavitation meters used in this study responded to acoustic pressure generated by the direct applied acoustic field and therefore tended to overestimate the occurrence of cavitation within the vessel, giving non-zero responses under conditions when there was known to be no inertial cavitation occurring with the reference vessel. This has implications for interpreting the data they provide in user applications. Copyright © 2016. Published by Elsevier B.V.

  4. Characterizing the cavitation development and acoustic spectrum in various liquids.

    Science.gov (United States)

    Tzanakis, I; Lebon, G S B; Eskin, D G; Pericleous, K A

    2017-01-01

    A bespoke cavitometer that measures acoustic spectrum and is capable of operating in a range of temperatures (up to 750°C) was used to study the cavitation behaviour in three transparent liquids and in molten aluminium. To relate these acoustic measurements to cavitation development, the dynamics of the cavitation bubble structures was observed in three Newtonian, optically transparent liquids with significantly different physical properties: water, ethanol, and glycerine. Each liquid was treated at 20kHz with a piezoelectric ultrasonic transducer coupled to a titanium sonotrode with a tip diameter of 40mm. Two different transducer power levels were deployed: 50% and 100%, with the maximum power corresponding to a peak-to-peak amplitude of 17μm. The cavitation structures and the flow patterns were filmed with a digital camera. To investigate the effect of distance from the ultrasound source on the cavitation intensity, acoustic emissions were measured with the cavitometer at two points: below the sonotrode and near the edge of the experimental vessel. The behaviour of the three tested liquids was very different, implying that their physical parameters played a decisive role in the establishment of the cavitation regime. Non dimensional analysis revealed that water shares the closest cavitation behaviour with liquid aluminium and can therefore be used as its physical analogue in cavitation studies; this similarity was also confirmed when comparing the measured acoustic spectra of water and liquid aluminium. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  5. Compressible Turbulent Flow Numerical Simulations of Tip Vortex Cavitation

    NARCIS (Netherlands)

    Khatami, F.; van der Weide, Edwin Theodorus Antonius; Hoeijmakers, Hendrik Willem Marie

    2015-01-01

    For an elliptic Arndt’s hydrofoil numerical simulations of vortex cavitation are presented. An equilibrium cavitation model is employed. This single-fluid model assumes local thermodynamic and mechanical equilibrium in the mixture region of the flow, is employed. Furthermore, for characterizing the

  6. Suppression of Fatigue Crack Propagation of Duralumin by Cavitation Peening

    Directory of Open Access Journals (Sweden)

    Hitoshi Soyama

    2015-08-01

    Full Text Available It was demonstrated in the present paper that cavitation peening which is one of the mechanical surface modification technique can suppress fatigue crack propagation in duralumin. The impacts produced when cavitation bubble collapses can be utilised for the mechanical surface modification technique in the same way as laser peening and shot peening, which is called “cavitation peening”. Cavitation peening employing a cavitating jet in water was used to treat the specimen made of duralumin Japanese Industrial Standards JIS A2017-T3. After introducing a notch, fatigue test was conducted by a load-controlled plate bending fatigue tester, which has been originally developed. The fatigue crack propagation behavior was evaluated and the relationship between the fatigue crack propagation rate versus stress intensity factor range was obtained. From the results, the fatigue crack propagation rate was drastically reduced by cavitation peening and the fatigue life of duralumin plate was extended 4.2 times by cavitation peening. In addition, the fatigue crack propagation can be suppressed by 88% in the stable crack propagation stage by cavitation peening.

  7. The acceleration of solid particles subjected to cavitation nucleation

    DEFF Research Database (Denmark)

    Borkent, B.M.; Arora, M.; Ohl, C.-D.

    2008-01-01

    The cavity -particle dynamics at cavitation inception on the surface of spherical particles suspended in water and exposed to a strong tensile stress wave is experimentally studied with high-speed photography. Particles, which serve as nucleation sites for cavitation bubbles, are set into a fast...

  8. A continuum damage relation for hydrogen attack cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Burg, M.W.D. van der; Giessen, E. van der [Delft Univ. of Technology (Netherlands). Lab. for Engineering Mechanics

    1997-07-01

    A continuum damage relation (CDR) is proposed to describe the failure process of hydrogen attack, i.e., grain boundary cavitation of steels under conditions of high temperature and high hydrogen pressure. The cavitation is caused by the chemical reaction of hydrogen with grain boundary carbides forming cavities filled with high pressure methane. The micromechanisms described are the grain boundary cavitation and the dislocation creep of the grains. The CDR is based on two extreme cavitation rate distribution modes. In the first mode, the cavitation rate along the facets is uniform, resulting in a hydrostatic dilatation while the creep deformations remain relatively small. In the second mode, cavitation proceeds predominantly on grain boundary facets transverse to the principal macroscopic stress. This part of the CDR builds on Tvergaard`s constitutive relation for intergranular creep rupture [Tvergaard, V., Acta Metallurgica, 1984, 32, 1977] where the facet cavitation is constrained by creep of the surrounding grains. The mode corresponding to the highest cavitation rate is the active mode. The two-dimensional version of the CDR is verified against detailed finite element analyses of hydrogen attack in planar polycrystalline aggregates. Finally, the generalization to a three-dimensional CDR is discussed.

  9. VibroCav : Hydrodynamic Vibration and Cavitation Technology

    NARCIS (Netherlands)

    Bakker, T.W.

    2012-01-01

    Vibration and cavitation can be generated in many ways and serve many useful purposes. This study describes physical aspects of useful vibration and cavitation for a broad spectrum of applications at atmospheric or elevated pressures. After a review of available devices, hydrodynamic

  10. Radiation induced cavitation: A possible phenomenon in liquid targets?

    Energy Technology Data Exchange (ETDEWEB)

    West, C.D.

    1998-07-01

    The proposed design of a new, short-pulse spallation neutron source includes a liquid mercury target irradiated with a 1 GeV proton beam. This paper explores the possibility that cavitation bubbles may be formed in the mercury and briefly discusses some design features that could avoid harmful effects should cavitation take place.

  11. Cavitation-aided grain refinement in aluminium alloys

    NARCIS (Netherlands)

    Atamanenko, T.V.

    2010-01-01

    This thesis deals with grain refinement under the influence of ultrasonic-driven cavitation in aluminium casting processes. Three major goals of this research were: (1) to identify the mechanism of the cavitation-aided grain refinement at different stages of solidification; (2) to reveal the

  12. A Experimental Investigation of Acoustic Cavitation in Gaseous Liquids

    Science.gov (United States)

    Gaitan, Dario Felipe

    1990-01-01

    High amplitude radial pulsations of a single gas bubble in several glycerine and water mixtures have been observed in an acoustic stationary wave system at acoustic pressure amplitudes as high as 1.5 bars. Using a laser scattering technique, radius-time curves have been obtained experimentally which confirm the absence of surface waves. Measurements of the pulsation amplitude, the timing of the major bubble collapse, and the number of rebounds have been made and compared with the theory. From these data, calculations of the internal gas temperature and pressure during the collapse have been performed. Values of at least 2,000 K and 2,000 bars have been obtained using a sophisticated model of spherically symmetric bubble dynamics. Simultaneously, sonoluminescence (SL), a phenomenon discovered in 1933 and attributed today to the high temperatures and pressures generated during the collapse of the bubbles, were observed as short light pulses occurring once every acoustic period. The light emissions can be seen to originate at the geometric center of the bubble when observed through a microscope. Also, the simultaneity of the light emissions and the collapse of the bubble has been confirmed with the aid of a photomultiplier tube. This is the first recorded observation of SL generated by a single bubble. Comparisons of the measured quantities have been made to those predicted by several models. In addition, the implications of this research on the current understanding of cavitation related phenomena such as rectified diffusion, surface wave excitation and sonoluminescence will be discussed. Some possible future experiments are suggested which could further increase our understanding of cavitation bubble dynamics.

  13. Study of the cavitating instability on a grooved Venturi profile

    CERN Document Server

    Danlos, Amélie; Ravelet, Florent; Coutier-Delgosha, Olivier; Bakir, Farid

    2012-01-01

    Cavitation is a limiting phenomenon in many domains of fluid mechanics. Instabilities of a partial cavity developed on an hydrofoil, a converging-diverging step or in an inter-blade channel in turbomachinery, have already been investigated and described in many previous works. The aim of this study is to evaluate a passive control method of the sheet cavity. According to operating conditions, cavitation can be described by two different regimes: an unstable regime with a cloud cavitation shedding and a stable regime with only a pulsating sheet cavity. Avoiding cloud cavitation can limit structure damages since a pulsating sheet cavity is less agressive. The surface condition of a converging-diverging step, like a Venturi-type obstacle, is here studied as a solution for a passive control of the cavitation. This study discusses the effect of an organized roughness, in the shape of longitudinal grooves, on the developed sheet cavity. Analyzes conducted with Laser Doppler Velocimetry, visualisations and pressure ...

  14. Observation of Microhollows Produced by Bubble Cloud Cavitation

    Science.gov (United States)

    Yamakoshi, Yoshiki; Miwa, Takashi

    2012-07-01

    When an ultrasonic wave with sound pressure less than the threshold level of bubble destruction irradiates microbubbles, the microbubbles aggregate by an acoustic radiation force and form bubble clouds. The cavitation of bubble clouds produces a large number of microhollows (microdips) on the flow channel wall. In this study, microhollow production by bubble cloud cavitation is evaluated using a blood vessel phantom made of N-isopropylacrylamide (NIPA) gel. Microbubble dynamics in bubble cloud cavitation is observed by a microscope with a short pulse light emitted diode (LED) light source. Microhollows produced on the flow channel wall are evaluated by a confocal laser microscope with a water immersion objective. It is observed that a mass of low-density bubbles (bubble mist) is formed by bubble cloud cavitation. The spatial correlation between the bubble mist and the microhollows shows the importance of the bubble mist in microhollow production by bubble cloud cavitation.

  15. Non-cavitating propeller noise modeling and inversion

    Science.gov (United States)

    Kim, Dongho; Lee, Keunhwa; Seong, Woojae

    2014-12-01

    Marine propeller is the dominant exciter of the hull surface above it causing high level of noise and vibration in the ship structure. Recent successful developments have led to non-cavitating propeller designs and thus present focus is the non-cavitating characteristics of propeller such as hydrodynamic noise and its induced hull excitation. In this paper, analytic source model of propeller non-cavitating noise, described by longitudinal quadrupoles and dipoles, is suggested based on the propeller hydrodynamics. To find the source unknown parameters, the multi-parameter inversion technique is adopted using the pressure data obtained from the model scale experiment and pressure field replicas calculated by boundary element method. The inversion results show that the proposed source model is appropriate in modeling non-cavitating propeller noise. The result of this study can be utilized in the prediction of propeller non-cavitating noise and hull excitation at various stages in design and analysis.

  16. AN EFFICIENT TREATMENT STRATEGY FOR HISTOTRIPSY BY REMOVING CAVITATION MEMORY

    Science.gov (United States)

    Wang, Tzu-Yin; Xu, Zhen; Hall, Timothy L.; Fowlkes, J. Brian; Cain, Charles A.

    2012-01-01

    Cavitation memory effects occur when remnants of cavitation bubbles (nuclei) persist in the host medium and act as seeds for subsequent events. In pulsed cavitational ultrasound therapy, or histotripsy, this effect may cause cavitation to repeatedly occur at these seeded locations within a target volume, producing inhomogeneous tissue fractionation or requiring an excess number of pulses to completely homogenize the target volume. We hypothesized that by removing the cavitation memory, i.e., the persistent nuclei, the cavitation bubbles could be induced at random locations in response to each pulse; therefore, complete disruption of a tissue volume may be achieved with fewer pulses. To test the hypothesis, the cavitation memory was passively removed by increasing the intervals between successive pulses, Δt, from 2, 10, 20, 50 and 100, to 200 ms. Histotripsy treatments were performed in red blood cell tissue phantoms and ex vivo livers using 1-MHz ultrasound pulses of 10 cycles at P−/P+ pressure of 21/59 MPa. The phantom study allowed for direct visualization of the cavitation patterns and the lesion development process in real time using high-speed photography; the ex vivo tissue study provided validation of the memory effect in real tissues. Results of the phantom study showed an exponential decrease in the correlation coefficient between cavitation patterns in successive pulses from 0.5 ± 0.1 to 0.1 ± 0.1 as Δt increased from 2–200 ms; correspondingly, the lesion was completely fractionated with significantly fewer pulses for longer Δts. In the tissue study, given the same number of therapy pulses, complete and homogeneous tissue fractionation with well-defined lesion boundaries was achieved only for Δt ≥ 100 ms. These results indicated that the removal of the cavitation memory resulted in more efficient treatments and homogeneous lesions. PMID:22402025

  17. Retrograde root filling with amalgam and Cavit.

    Science.gov (United States)

    Finne, K; Nord, P G; Persson, G; Lennartsson, B

    1977-04-01

    In a 3-year review of 218 teeth with retrograde root filling with amalgam orCavit, the results obtained with the former proved significantly better than those obtained with the latter. The difference seemed to be due to a better obliteration of the canal by amalgam. The obliterating effect of amalgam probably eliminates the need for revision of incomplete othograde root filling, for example, in cases with a post in the root canal. Irrespective of type of filling materials, the results were less good in cases with marginal bone loss.

  18. Peripapillary intrachoroidal cavitation in pathological myopia.

    Science.gov (United States)

    Marticorena-Álvarez, P; Clement-Fernández, F; Iglesias-Ussel, L

    2014-08-01

    A 54 year old woman with pathological myopia, presented with an elevated, yellowish-white lesion at the inferior border of the myopic conus in her left eye. The optical coherence tomography (OCT) demonstrated an intrachoroidal hyporeflective space. The fluorescein angiography examination (FA) showed early hypofluorescence with delayed staining, with no leakage of contrast. Recognition of «peripapillary intrachoroidal cavitation» as an own entity associated with pathological myopia is important to avoid confusion with other possible retinal lesions which require further investigation and treatment. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  19. Synovial fluid cavitation during distraction radiography of the coxofemoral joint in dogs.

    Science.gov (United States)

    LaFond, E; Smith, G K; Gregor, T P; McKelvie, P J; Shofer, F S

    1997-05-01

    To determine risk factors for, and prevalence and short- and long-term effects of synovial fluid cavitation during distraction radiography. Multicenter prevalence survey. 6,649 purebred dogs comprising 129 breeds. Radiographs from the PennHIP (University of Pennsylvania Hip Improvement Program) Laboratory were subjectively evaluated for evidence of cavitation. Multiple logistic regression was used to determine whether sex, breed, age, weight, distraction index (DI), or examining veterinarian was associated with cavitation. Short-term effects of cavitation were assessed by comparing DI for the hip with cavitation with DI for the contralateral hip in dogs with unilateral cavitation. Long-term effects of cavitation were assessed by comparing DI before and after cavitation was detected. Cavitation was detected in 279 (4.2%) of the radiographs analyzed. Male dogs, Golden Retrievers, and heavier dogs were at a decreased risk for cavitation. Irish Wolfhounds, Irish Setters, Rhodesian Ridgebacks, and Weimaraners had an increased risk for cavitation. Age and DI were not risk factors for cavitation. Mean DI was 0.08 greater in hips with cavitation than in paired hips without cavitation. Significant differences were not detected between DI before and after cavitation, but only 7 dogs were included in this analysis. Cavitation is rare during distraction radiography and can increase measured DI. Radiographs should be routinely examined to ensure accurate reporting of DI.

  20. Cavitation erosion of copper and aluminium in water at elevated-temperature

    CSIR Research Space (South Africa)

    Auret, JG

    1993-12-01

    Full Text Available Cavitation erosion tests were carried out in tap water on aluminium and copper samples in a rotating disk cavitations test apparatus, to study the effect of water temperature on cavitation dynamics and cavitation erosion. A shift in the position...

  1. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study.

    Science.gov (United States)

    Nascimento, Dahan da Cunha; Tibana, Ramires Alsamir; Benik, Franklin M; Fontana, Keila Elizabeth; Ribeiro Neto, Frederico; Santana, Frederico Santos de; Santos-Neto, Leopoldo; Silva, Renato André Sousa; Silva, Alessandro Oliveira; Farias, Darlan Lopes; Balsamo, Sandor; Prestes, Jonato

    2014-01-01

    Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. This study examined the effects of a 14-week moderate intensity resistance training program (RT) on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001), relative hand grip strength (P=0.032) and a decrease of systolic (P=0.001), diastolic (P=0.008), and mean blood pressure (P=0.002) when compared to pre-exercise values. In addition, these effects were sustained after 14 weeks of detraining. Resistance training may be a valuable method to improve muscular strength and blood pressure in elderly people with benefits being maintained up to 14 weeks following training cessation.

  2. [Particle size reduction using acoustic cavitation].

    Science.gov (United States)

    Bartos, Csilla; Ambrus, Rita; Szabóné, Révész Piroska

    2014-01-01

    Different pharmaceutical technological processes have been used for modification of the physico-chemical and biopharmaceutical properties of drugs. Changes of crystal size, distribution and morphology can open up new, alternative administration routes, e.g. intranasally and the pulmonary route, where the particle size is a determining factor. A wet grinding method based on acoustic cavitation (the collapse of bubbles or voids formed by sound waves) is a novel possibility for modification of the properties of particles. During our work this wet grinding technique was studied. The effect of this method was investigated on particle size reduction. The samples were treated with extreme sonication parameters. The effect of the concentration of the polymer was examined on the particle size reduction. Meloxicam was chosen as a model crystalline drug because of its poor aqueous solubility. The structural characterization and the morphological analysis of the dried products were carried out by DSC, XRPD and SEM. It was found that the acoustic cavitation resulted in crystalline micronized product.

  3. Characterization of the cavitating flow in converging-diverging nozzle based on experimental investigations

    Directory of Open Access Journals (Sweden)

    Rudolf Pavel

    2014-03-01

    Full Text Available Cavitation phenomena occuring in converging-diverging nozzle (Venturi tube are described in the paper. A closed test circuit with possibility to control both flow rate and static pressure level were used. Loss coefficient was evaluated for different sigma numbers resulting in full „static“ characterization of the nozzle. Visualizations of the cavitation pattern development were acquired and matched with evolution of the loss coefficient. Three cavitation regimes are described: partial cavitation, fully developed cavitation, supercavitation.

  4. The effect of the aortic valve orientation on cavitation.

    Science.gov (United States)

    Johansen, Peter; Travis, Brandon R; Smerup, Morten; Decker Christensen, Thomas; Funder, Jonas; Nyboe, Camilla; Nygaard, Hans; Hasenkam, J Michael

    2016-08-01

    When implanting a mechanical aortic valve the annulus orientation is important with respect to turbulence. However, the effect on cavitation has not yet been investigated. The aim of this study was to investigate how cavitation is influenced hereof in vivo. Three pigs were included in the study. An Omnicarbon 21mm valve equipped with a rotating mechanism enabling controlled rotation of the valve was implanted in aortic position. Under stable hemodynamic conditions, measurements were performed using a hydrophone positioned at the aortic root. The valve was rotated from 0-360° in increments of 30°. From the pressure fluctuations recorded by the hydrophone the root mean square of the 50 kHz high pass filtered signal as well as the non-deterministic signal energy was calculated as indirect measures of cavitation. Various degrees of cavitation were measured but no relationship was found between either of the two cavitation measures and the valve orientation. Hemodynamics varied during the experiments for all pigs (3.9-5.7 l/min; 5.0-7.2 l/min; 3.1-7.5 l/min). Changes in cavitation quantities seemed to be caused by changes in hemodynamics rather than valve angular position. In conclusion, these results do not favor any position over another in terms of cavitation potential.

  5. Use of hydrodynamic cavitation in (waste)water treatment.

    Science.gov (United States)

    Dular, Matevž; Griessler-Bulc, Tjaša; Gutierrez-Aguirre, Ion; Heath, Ester; Kosjek, Tina; Krivograd Klemenčič, Aleksandra; Oder, Martina; Petkovšek, Martin; Rački, Nejc; Ravnikar, Maja; Šarc, Andrej; Širok, Brane; Zupanc, Mojca; Žitnik, Miha; Kompare, Boris

    2016-03-01

    The use of acoustic cavitation for water and wastewater treatment (cleaning) is a well known procedure. Yet, the use of hydrodynamic cavitation as a sole technique or in combination with other techniques such as ultrasound has only recently been suggested and employed. In the first part of this paper a general overview of techniques that employ hydrodynamic cavitation for cleaning of water and wastewater is presented. In the second part of the paper the focus is on our own most recent work using hydrodynamic cavitation for removal of pharmaceuticals (clofibric acid, ibuprofen, ketoprofen, naproxen, diclofenac, carbamazepine), toxic cyanobacteria (Microcystis aeruginosa), green microalgae (Chlorella vulgaris), bacteria (Legionella pneumophila) and viruses (Rotavirus) from water and wastewater. As will be shown, hydrodynamic cavitation, like acoustic, can manifest itself in many different forms each having its own distinctive properties and mechanisms. This was until now neglected, which eventually led to poor performance of the technique. We will show that a different type of hydrodynamic cavitation (different removal mechanism) is required for successful removal of different pollutants. The path to use hydrodynamic cavitation as a routine water cleaning method is still long, but recent results have already shown great potential for optimisation, which could lead to a low energy tool for water and wastewater cleaning. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Ultrasound imaging for cavitation detection during HIFU ablation in brain

    Science.gov (United States)

    Long, Tao; Amin, Viren; McClure, Scott; Roberts, Ronald; Wu, Liangshou; Heise, Matthew; Ryken, Timothy

    2007-03-01

    High intensity focused ultrasound (abbreviated as HIFU) has its potential in tumor treatment due to its non-invasive benefits. During HIFU exposure, cavitation (generation of gas bubbles) is often observed, which can be an indication of potential lesion created by HIFU power. Due to a large difference in ultrasound acoustic properties between the gas bubble and surrounding tissues, ultrasonic energy is reflected and scattered at the HIFU focus, thus indicating activity around the focal area and often interfering HIFU dosage delivery. A good understanding and control of cavitation phenomenon could potentially enhance the HIFU delivery and treatment outcomes. Quantifying the onset timing and extent of the cavitation could be potentially used for detecting HIFU effects and therapy guidance. In this paper, we study the relationships among HIFU parameters, the characteristics of cavitation quantified from ultrasound imaging, and characteristics of the final tissue lesion created by HIFU. In our study, we used 12 freshly excised pig brains in vitro for observation and analysis of cavitation activities during HIFU exposure with different HIFU parameters. Final lesions were examined by slicing the brain tissues into thin slices and 3D volume was constructed with segmentation of the lesion. HIFU parameters, cavitation activities through image processing and lesion characterization were correlated. We also present our initial understanding of the process of cavitation activities under certain HIFU parameters and control of such activities that could lead to optimal lesion

  7. Effects of HIFU induced cavitation on flooded lung parenchyma.

    Science.gov (United States)

    Wolfram, Frank; Dietrich, Georg; Boltze, Carsten; Jenderka, Klaus Vitold; Lesser, Thomas Günther

    2017-01-01

    High intensity focused ultrasound (HIFU) has gained clinical interest as a non-invasive local tumour therapy in many organs. In addition, it has been shown that lung cancer can be targeted by HIFU using One-Lung Flooding (OLF). OLF generates a gas free saline-lung compound in one lung wing and therefore acoustic access to central lung tumours. It can be assumed that lung parenchyma is exposed to ultrasound intensities in the pre-focal path and in cases of misguiding. If so, cavitation might be induced in the saline fraction of flooded lung and cause tissue damage. Therefore this study was aimed to determine the thresholds of HIFU induced cavitation and tissue erosion in flooded lung. Resected human lung lobes were flooded ex-vivo. HIFU (1,1 MHz) was targeted under sonographic guidance into flooded lung parenchyma. Cavitation events were counted using subharmonic passive cavitation detection (PCD). B-Mode imaging was used to detect cavitation and erosion sonographically. Tissue samples out of the focal zone were analysed histologically. In flooded lung, a PCD and a sonographic cavitation detection threshold of 625  Wcm - 2 ( p r  = 4, 3  MPa ) and 3.600  Wcm - 2 ( p r  = 8, 3  MPa ) was found. Cavitation in flooded lung appears as blurred hyperechoic focal region, which enhances echogenity with insonation time. Lung parenchyma erosion was detected at intensities above 7.200  Wcm - 2 ( p r  = 10, 9  MPa ). Cavitation occurs in flooded lung parenchyma, which can be detected passively and by B-Mode imaging. Focal intensities required for lung tumour ablation are below levels where erosive events occur. Therefore focal cavitation events can be monitored and potential risk from tissue erosion in flooded lung avoided.

  8. Transient pressure signals in mechanical heart valve cavitation.

    Science.gov (United States)

    Wu, Z J; Slonin, J H; Hwang, N H

    1996-01-01

    The purpose of this investigation was to establish a correlation between mechanical heart valve (MHV) cavitation and transient pressure (TP) signals at MHV closure. This correlation may suggest a possible method to detect in vivo MHV cavitation. In a pulsatile mock flow loop, a study was performed to measure TP and observe cavitation bubble inception at MHV closure under simulated physiologic ventricular and aortic pressures at heart rates of 70, 90, 120, and 140 beats/min with corresponding cardiac outputs of 5.0, 6.0, 7.5, and 8.5 L/min, respectively. The experimental study included two bileaflet MHV prostheses: 1) St. Jude Medical 31 mm and 2) Carbomedics 31 mm. High fidelity piezo-electric pressure transducers were used to measure TP immediately before and after the valve leaflet/housing impact. A stroboscopic lighting imaging technique was developed to capture cavitation bubbles on the MHV inflow surfaces at selected time delays ranging from 25 microseconds to 1 ms after the leaflet/housing impact. The TP traces measured 10 mm away from the valve leaflet tip showed a large pressure reduction peak at the leaflet/housing impact, and subsequent high frequency pressure oscillations (HPOs) while the cavitation bubbles were observed. The occurrence of cavitation bubbles and HPO bursts were found to be random on a beat by beat basis. However, the amplitude of the TP reduction, the intensity of the cavitation bubble (size and number), and the intensity of HPO were found to increase with the test heart rate. A correlation between the MHV cavitation bubbles and the HPO burst was positively established. Power spectrum analysis of the TP signals further showed that the frequency of the HPO (cavitation bubble collapse pressures) ranged from 100 to 450 kHz.

  9. Mechanical heart valve cavitation in patients with bileaflet valves.

    Science.gov (United States)

    Johansen, Peter; Andersen, Tina S; Hasenkam, J Michael; Nygaard, Hans; Paulsen, Peter K

    2014-01-01

    Today, the quality of mechanical heart valves is quite high, and implantation has become a routine clinical procedure with a low operative mortality (mechanism found to be a possible contributor to these adverse effects is cavitation. In vitro, cavitation has been directly demonstrated by visualization and indirectly in vivo by registering of high frequency pressure fluctuations (HFPF). Tilting disc valves are thought of having higher cavitation potential than bileaflet valves due to higher closing velocities. However, the thromboembolic potential seems to be the same. Further studies are therefore needed to investigate the cavitation potential of bileaflet valves in vivo. The post processing of HFPF have shown difficulties when applied on bileaflet vavles due to asynchronous closure of the two leaflets. The aim of this study was therefore to isolate the pressure signature from each leaflet closure and perform cavitation analyses on each component. Six patients were included in the study (St. Jude Medical (n=3) and CarboMedics (n=3); all aortic bileaflet mechanical heart valves). HFPFs were recorded intraoperatively through a hydrophone at the aortic root. The pressure signature relating to the first and second leaflet closure was isolated and cavitation parameters were calculated (RMS after 50 kHz highpass filtering and signal energy). Data were averaged over 30 heart cycles. For all patients both the RMS value and signal energy of the second leaflet closure were higher than for the first leaflet closure. This indicates that the second leaflet closure is most prone to cause cavitation. Therefore, quantifying cavitation based on the HFPF related to the second leaflet closure may suggest that the cavitation potential for bileaflet valves in vivo may be higher than previous studies have suggested.

  10. Transcranial cavitation-mediated ultrasound therapy at sub-MHz frequency via temporal interference modulation

    Science.gov (United States)

    Sun, Tao; Sutton, Jonathan T.; Power, Chanikarn; Zhang, Yongzhi; Miller, Eric L.; McDannold, Nathan J.

    2017-10-01

    Sub-megahertz transmission is not usually adopted in pre-clinical small animal experiments for focused ultrasound (FUS) brain therapy due to the large focal size. However, low frequency FUS is vital for preclinical evaluations due to the frequency-dependence of cavitation behavior. To maximize clinical relevance, a dual-aperture FUS system was designed for low-frequency (274.3 kHz) cavitation-mediated FUS therapy. Combining two spherically curved transducers provides significantly improved focusing in the axial direction while yielding an interference pattern with strong side lobes, leading to inhomogeneously distributed cavitation activities. By operating the two transducers at slightly offset frequencies to modulate this interference pattern over the period of sonication, the acoustic energy was redistributed and resulted in a spatially homogenous treatment profile. Simulation and pressure field measurements in water were performed to assess the beam profiles. In addition, the system performance was demonstrated in vivo in rats via drug delivery through microbubble-mediated blood-brain barrier disruption. This design resulted in a homogenous treatment profile that was fully contained within the rat brain at a clinically relevant acoustic frequency.

  11. The dynamics of cavity clusters in ultrasonic (vibratory) cavitation erosion

    DEFF Research Database (Denmark)

    Hansson, I.; Mørch, Knud Aage

    1980-01-01

    The erosion of solids caused by cavitating liquids is a result of the concerted collapse of clusters of cavities. In vibratory cavitation equipment the clusters grow and collapse adjacent to a solid surface and are typically of hemispherical or cylindrical form. In the present paper the collapse...... process of these clusters is described and the collapse equations are developed and solved. The theoretical results are compared with results from high-speed photography of the clusters and with the initial stages of cavitation erosion on metal specimens. Experimental and theoretical results show...

  12. Pressure and velocity dependence of flow-type cavitation erosion

    CSIR Research Space (South Africa)

    Auret, JG

    1993-12-01

    Full Text Available for rotating disc test rig Parameter Static water pressure Water temperature Sample velocity Air content of water Water flow rate Water quality Range 0.1-2 MPa Ambient to 100 ?C ~40-60 m s-l Deaerated to supersaturated O-30 1... ship?s screw), as opposed to vibratory cavitation erosion. For flow-type cavitation erosion, well-defined rela- tions exist between the flow velocity and liquid pressure, and the amount of cavitation and erosion damage...

  13. Experimental determination of cavitation thresholds in liquid water and mercury

    Energy Technology Data Exchange (ETDEWEB)

    Taleyarkhan, R.P.; West, C.D. [Oak Ridge National Lab., TN (United States); Moraga, F. [Rensselaer Polytechnic Inst., Troy, NY (United States)

    1998-11-01

    An overview is provided on cavitation threshold measurement experiments for water and mercury. Various aspects to be considered that affect onset determination are discussed along with design specifications developed for construction of appropriate apparatus types. Both static and transient-cavitation effects were studied using radically different apparatus designs. Preliminary data are presented for cavitation thresholds for water and mercury over a range of temperatures in static and high-frequency environments. Implications and issues related to spallation neutron source target designs and operation are discussed.

  14. Influence of the Cavitation Model on the Simulation of Cloud Cavitation on 2D Foil Section

    Directory of Open Access Journals (Sweden)

    S. Frikha

    2008-01-01

    Full Text Available For numerical simulations of cavitating flows, many physical models are currently used. One approach is the void fraction transport equation-based model including source terms for vaporization and condensation processes. Various source terms have been proposed by different researchers. However, they have been tested only in different flow configurations, which make direct comparisons between the results difficult. A comparative study, based on the expression of the source terms as a function of the pressure, is presented in the present paper. This analytical approach demonstrates a large resemblance between the models, and it also clarifies the influence of the model parameters on the vaporization and condensation terms and, therefore, on the cavity shape and behavior. Some of the models were also tested using a 2D CFD code in configurations of cavitation on two-dimensional foil sections. Void fraction distributions and frequency of the cavity oscillations were compared to existing experimental measurements. These numerical results confirm the analytical study.

  15. Flow visualization in the high shear flow on cavitation erosion around a butterfly valve. Butterfly ben karyu no ko sendanryoiki ni okeru cavitation shogekiatsu bunpu

    Energy Technology Data Exchange (ETDEWEB)

    Tani, K. (Tohoku University, Sendai (Japan)); Ito, Y.; Oba, R. (Tohoku University, Sendai (Japan). Inst. of Fluid Science)

    1991-05-25

    In order to suppress the cavitation erosion occurring at a butterfly valve, the spatial distribution of cavitation induced pressure pulses and the aspect of extremely erosive vortex cavitation in the erosive region recognized in a practical valve were clarified, using pressure sensitive films and an instant stereophotography for the representative valve opening and cavitation factor. The highly erosive cavitation taking place at the orifice side downstream of the butterfly valve is an extremely erosive cavitation, and the occurred region is limited to the highly shear layers forming the violent disturbance of the orifice jet. It was found that the erosion could greatly be alleviated by eliminating this highly shear layers being the basis of the extremely erosive vortex cavitation. It was also found that the risk of erosion was very low for the nozzle side by the measurement of cavitation impact pressure ranging all periphery of the pipe wall around the valve body. 10 refs., 5 figs.

  16. Localization in an acoustic cavitation cloud

    CERN Document Server

    Miao, Boya

    2016-01-01

    Using a nonlinear sound wave equation for a bubbly liquid in conjunction with an equation for bubble pulsation, we predict and experimentally demonstrate the appearance of a gap in the frequency spectrum of a sound wave propagating in a cavitation cloud comprising bubbles. For bubbles with an ambient radius of 100 {\\mu}m, the calculations revealed that this gap corresponds to the phenomenon of sound wave localization. For bubbles with an ambient radius of 120 {\\mu}m, this spectral gap relates to a forbidden band of the sound wave. In the experiment, we observed the predicted gap in the frequency spectrum in soda water; however, in tap water, no spectral gap was present because the bubbles were much smaller than 100 {\\mu}m.

  17. Inverse Analysis of Cavitation Impact Phenomena on Structures

    National Research Council Canada - National Science Library

    Lambrakos, S. G; Tran, N. E

    2007-01-01

    A general methodology is presented for in situ detection of cavitation impact phenomena on structures based on inverse analysis of luminescent emissions resulting from the collapsing of bubbles onto surfaces...

  18. Mathematical Modelling of Fluid Flow in Cone and Cavitation Formation

    Directory of Open Access Journals (Sweden)

    Milada KOZUBKOVÁ

    2011-06-01

    Full Text Available Problem of cavitation is the undesirable phenomena occuring in the fluid flow in many hydraulic application (pumps, turbines, valves, etc.. Therefore this is in the focus of interest using experimental and mathematical methods. Based on cavitation modelling in Laval nozzle results and experience [1], [2], [4], following problem described as the water flow at the outlet from turbine blade wheel was solved. Primarily the problem is simplified into modelling of water flow in cone. Profiles of axial, radial and tangential velocity are defined on inlet zone. The value of pressure is defined on the outlet. Boundary conditions were defined by main investigator of the grant project – Energy Institute, Victor Kaplan’s Department of Fluid Engineering, Faculty of Mechanical Engineering, Brno University of Technology. The value of air volume was insignificant. Cavitation was solved by Singhal model of cavitation.

  19. Optimization of centrifugal pump cavitation performance based on CFD

    Science.gov (United States)

    Xie, S. F.; Wang, Y.; Liu, Z. C.; Zhu, Z. T.; Ning, C.; Zhao, L. F.

    2015-01-01

    In order to further improve the cavitation performance of a centrifugal pump, slots on impeller blade near inlet were studied and six groups of hydraulic model were designed. Base on cavitating flow feature inside a centrifugal pump, bubble growth and implosion are calculated from the Rayleigh-Plesset equation which describes the dynamic behavior of spherical bubble and RNG κ-epsilon model was employed to simulate and analyze the internal two-phase flow of the model pump under the same conditions. The simulation results show that slots on blade near inlet could improve the cavitation performance and cavitation performance improvement of the second group was more obvious. Under the same conditions, the pressure on the back of blade near inlet was higher than the pressure on the back of unmodified blade near inlet, and energy distribution in the flow channel between the two blades was more uniform with a small change of head.

  20. Cavitation instabilities between fibres in a metal matrix composite

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    2016-01-01

    Short fibre reinforced metal matrix composites (MMC) are studied here to investigate the possibility that a cavitation instability can develop in the metal matrix. The high stress levels needed for a cavitation instability may occur in metal–ceramic systems due to the constraint on plastic flow...... of transversely staggered fibres is here modelled by using an axisymmetric cell model analysis. First the critical stress level is determined for a cavitation instability in an infinite solid made of the Al matrix material. By studying composites with different distributions and aspect ratios of the fibres...... it is shown that regions between fibre ends may develop hydrostatic tensile stresses high enough to exceed the critical level for a cavitation instability. For cases where a void is located in such regions it is shown that unstable cavity growth develops when the void is initially much smaller than the highly...

  1. Flow Modelling for partially Cavitating Two-dimensional Hydrofoils

    DEFF Research Database (Denmark)

    Krishnaswamy, Paddy

    2001-01-01

    The present work addresses te computational analysis of partial sheet hydrofoil cavitation in two dimensions. Particular attention is given to the method of simulating the flow at the end of the cavity. A fixed-length partially cavitating panel method is used to predict the height of the re......-entrant jet, using the values of the cavitation number and the drag coefficient. The jet surface is subsequently constructed and inclued in an updated cavity shape. At the same time, a source singularity is introduced in the fluid domain to account for the mass flux through the part of the domain boundary...... represented by the re-entrant jet surface. Further iterations are performed for fixed cavitation number on the cavity with a re-entrant jet cavity termination model. This model is seen to produce good results and displays quick convergence. A validation is accomplished by conducting a parametric analysis...

  2. Analysis of Acoustic Cavitation Surge in a Rocket Engine Turbopump

    Directory of Open Access Journals (Sweden)

    Hideaki Nanri

    2010-01-01

    Full Text Available In a liquid rocket engine, cavitation in an inducer of a turbopump sometimes causes instability phenomena when the inducer is operated at low inlet pressure. Cavitation surge (auto-oscillation, one such instability phenomenon, has been discussed mainly based on an inertia model assuming incompressible flow. When this model is used, the frequency of the cavitation surge decreases continuously as the inlet pressure of the turbopump decreases. However, we obtained an interesting experimental result in which the frequency of cavitation surge varied discontinuously. Therefore, we employed one-dimensional analysis based on an acoustic model in which the fluid is assumed to be compressible. The analytical result qualitatively corresponded with the experimental result.

  3. Untreated Cavitated Dentine Lesions: Impact on Children's Quality of Life

    National Research Council Canada - National Science Library

    Leal, S.C; Bronkhorst, E.M; Fan, M; Frencken, J.E

    2012-01-01

    The aim of the present investigation was to assess the impact of dental caries prevalence and the consequences of untreated cavitated dentine lesions on quality of life of 6- and 7-year-old Brazilian children...

  4. Synergistic degradation of chitosan by impinging stream and jet cavitation.

    Science.gov (United States)

    Huang, Yongchun; Wang, Pengfei; Yuan, Yuan; Ren, Xian'e; Yang, Feng

    2015-11-01

    Chitosan degradation was investigated using a combination of jet cavitation and impinging stream. Different operating parameters such as the initial concentration (1-5 g L(-1)), initial pH (3.2-4.8), solution temperature (30, 40, 50, 60, and 70°C), inlet pressure (0.1-0.45 MPa), and treatment time (0-120 min) were optimized to achieve the maximum degradation of chitosan. After the optimization of jet cavitation parameters, chitosan degradation was carried out using venturi tubes of different structures (the fluidic generator). The efficiency of the jet cavitation degradation was improved significantly by combining with impinging stream. The structures of the degradation products were characterized by Fourier-transform infrared spectroscopy and X-ray diffraction. This study has conclusively established that a combination of jet cavitation and impinging stream can be effectively used for the complete degradation of chitosan. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Radial Shock Wave Devices Generate Cavitation.

    Science.gov (United States)

    Császár, Nikolaus B M; Angstman, Nicholas B; Milz, Stefan; Sprecher, Christoph M; Kobel, Philippe; Farhat, Mohamed; Furia, John P; Schmitz, Christoph

    2015-01-01

    Conflicting reports in the literature have raised the question whether radial extracorporeal shock wave therapy (rESWT) devices and vibrating massage devices have similar energy signatures and, hence, cause similar bioeffects in treated tissues. We used laser fiber optic probe hydrophone (FOPH) measurements, high-speed imaging and x-ray film analysis to compare fundamental elements of the energy signatures of two rESWT devices (Swiss DolorClast; Electro Medical Systems, Nyon, Switzerland; D-Actor 200; Storz Medical, Tägerwillen, Switzerland) and a vibrating massage device (Vibracare; G5/General Physiotherapy, Inc., Earth City, MO, USA). To assert potential bioeffects of these treatment modalities we investigated the influence of rESWT and vibrating massage devices on locomotion ability of Caenorhabditis elegans (C. elegans) worms. FOPH measurements demonstrated that both rESWT devices generated acoustic waves with comparable pressure and energy flux density. Furthermore, both rESWT devices generated cavitation as evidenced by high-speed imaging and caused mechanical damage on the surface of x-ray film. The vibrating massage device did not show any of these characteristics. Moreover, locomotion ability of C. elegans was statistically significantly impaired after exposure to radial extracorporeal shock waves but was unaffected after exposure of worms to the vibrating massage device. The results of the present study indicate that both energy signature and bioeffects of rESWT devices are fundamentally different from those of vibrating massage devices. Prior ESWT studies have shown that tissues treated with sufficient quantities of acoustic sound waves undergo cavitation build-up, mechanotransduction, and ultimately, a biological alteration that "kick-starts" the healing response. Due to their different treatment indications and contra-indications rESWT devices cannot be equated to vibrating massage devices and should be used with due caution in clinical practice.

  6. Radial Shock Wave Devices Generate Cavitation.

    Directory of Open Access Journals (Sweden)

    Nikolaus B M Császár

    Full Text Available Conflicting reports in the literature have raised the question whether radial extracorporeal shock wave therapy (rESWT devices and vibrating massage devices have similar energy signatures and, hence, cause similar bioeffects in treated tissues.We used laser fiber optic probe hydrophone (FOPH measurements, high-speed imaging and x-ray film analysis to compare fundamental elements of the energy signatures of two rESWT devices (Swiss DolorClast; Electro Medical Systems, Nyon, Switzerland; D-Actor 200; Storz Medical, Tägerwillen, Switzerland and a vibrating massage device (Vibracare; G5/General Physiotherapy, Inc., Earth City, MO, USA. To assert potential bioeffects of these treatment modalities we investigated the influence of rESWT and vibrating massage devices on locomotion ability of Caenorhabditis elegans (C. elegans worms.FOPH measurements demonstrated that both rESWT devices generated acoustic waves with comparable pressure and energy flux density. Furthermore, both rESWT devices generated cavitation as evidenced by high-speed imaging and caused mechanical damage on the surface of x-ray film. The vibrating massage device did not show any of these characteristics. Moreover, locomotion ability of C. elegans was statistically significantly impaired after exposure to radial extracorporeal shock waves but was unaffected after exposure of worms to the vibrating massage device.The results of the present study indicate that both energy signature and bioeffects of rESWT devices are fundamentally different from those of vibrating massage devices.Prior ESWT studies have shown that tissues treated with sufficient quantities of acoustic sound waves undergo cavitation build-up, mechanotransduction, and ultimately, a biological alteration that "kick-starts" the healing response. Due to their different treatment indications and contra-indications rESWT devices cannot be equated to vibrating massage devices and should be used with due caution in clinical

  7. Multi-focal HIFU reduces cavitation in mild-hyperthermia.

    Science.gov (United States)

    Chaplin, Vandiver; Caskey, Charles F

    2017-01-01

    Mild-hyperthermia therapy (40-45 °C) with high-intensity focused ultrasound (HIFU) is a technique being considered in a number of different treatments such as thermally activated drug delivery, immune-stimulation, and as a chemotherapy adjuvant. Mechanical damage and loss of cell viability associated with HIFU-induced acoustic cavitation may pose a risk during these treatments or may hinder their success. Here we present a method that achieves mild heating and reduces cavitation by using a multi-focused HIFU beam. We quantify cavitation level and temperature rise in multi-focal sonications and compare it to single-focus sonications at the transducer geometric focus. Continuous wave sonications were performed with the Sonalleve V2 transducer in gel phantoms and pork at 5, 10, 20, 40, 60, 80 acoustic watts for 30 s. Cavitation activity was measured with two ultrasound (US) imaging probes, both by computing the raw channel variance and using passive acoustic mapping (PAM). Temperature rise was measured with MR thermometry at 3 T. Cavitation and heating were compared for single- and multi-focal sonication geometries. Multi-focal sonications used four points equally spaced on a ring of either 4 mm or 8 mm diameter. Single-focus sonications were not steered. Multi-focal sonication generated distinct foci that were visible in MRI thermal maps in both phantoms and pork, and visible in PAM images in phantoms only. Cavitation activity (measured by channel variance) and mean PAM image value were highly correlated (r > 0.9). In phantoms, cavitation exponentially decreased over the 30-second sonication, consistent with depletion of cavitation nuclei. In pork, sporadic spikes signaling cavitation were observed with single focusing only. In both materials, the widest beam reduced average and peak cavitation level by a factor of two or more at each power tested when compared to a single focus. The widest beam reduced peak temperature by at least 10 °C at powers above 5

  8. Modelling on cavitation in a diffuser with vortex generator

    Directory of Open Access Journals (Sweden)

    Jablonská J.

    2013-04-01

    Full Text Available Based on cavitation modelling in Laval nozzle results and experience, problem with the diffuser with vortex generator was defined. The problem describes unsteady multiphase flow of water. Different cavitation models were used when modelling in Fluent, flow condition is inlet and pressure condition is outlet. Boundary conditions were specified by Energy Institute, Victor Kaplan’s Department of Fluid Engineering, Faculty of Mechanical Engineering, Brno University of Technology. Numerical modelling is compared with experiment.

  9. Cavitation fatigue and its reversal in sunflower (Helianthus annuus L.).

    Science.gov (United States)

    Stiller, Volker; Sperry, John S

    2002-05-01

    "Cavitation fatigue" is the increased susceptibility of a xylem conduit to cavitation as a result of its prior cavitation. It was investigated whether cavitation fatigue induced in vivo could be repaired in intact plants. Sunflowers (Helianthus annuus L.) were subjected to soil drought in the greenhouse. Native embolism and vulnerability to cavitation was measured in well-watered controls and after 5 d and 10 d of controlled drought. A dramatic cavitation fatigue was observed where droughted xylem that was refilled in the laboratory developed up to 60 PLC (percentage loss of hydraulic conductivity) at -1 MPa versus only 5.2 PLC in non-droughted controls. Rewatered plants showed the complete reversal of cavitation fatigue over 4 d. Reversal of fatigue was correlated with the refilling of embolized vessels in the intact plants (r(2)=0.91, P<0.01), suggesting that xylem transport to fatigued vessels was required for their repair. The in vivo reversal of fatigue was partially duplicated in excised stem segments by perfusing them with root exudates from droughted (DR) and well-watered (WW) plants. The DR exudate had a greater effect, and this was associated with a greater pH in the DR versus WW saps, but there was no difference in total cation concentration. Perfusions with 2 mM CaCl(2) and KCl solutions also partially reversed cavitation fatigue as opposed to no effect with deionized water, suggesting a role of ions in addition to a pH effect. It is suspected that fatigue is caused by stretching and partial disruption of linkages between cellulose microfibrils in inter-conduit pit membranes during air seeding, and that the reversal of fatigue involves restoring these linkages by ingredients in xylem sap.

  10. Vortex flow and cavitation in diesel injector nozzles

    Science.gov (United States)

    Andriotis, A.; Gavaises, M.; Arcoumanis, C.

    Flow visualization as well as three-dimensional cavitating flow simulations have been employed for characterizing the formation of cavitation inside transparent replicas of fuel injector valves used in low-speed two-stroke diesel engines. The designs tested have incorporated five-hole nozzles with cylindrical as well as tapered holes operating at different fixed needle lift positions. High-speed images have revealed the formation of an unsteady vapour structure upstream of the injection holes inside the nozzle volume, which is referred to as . Computation of the flow distribution and combination with three-dimensional reconstruction of the location of the strings inside the nozzle volume has revealed that strings are found at the core of recirculation zones; they originate either from pre-existing cavitation sites forming at sharp corners inside the nozzle where the pressure falls below the vapour pressure of the flowing liquid, or even from suction of outside air downstream of the hole exit. Processing of the acquired images has allowed estimation of the mean location and probability of appearance of the cavitating strings in the three-dimensional space as a function of needle lift, cavitation and Reynolds number. The frequency of appearance of the strings has been correlated with the Strouhal number of the vortices developing inside the sac volume; the latter has been found to be a function of needle lift and hole shape. The presence of strings has significantly affected the flow conditions at the nozzle exit, influencing the injected spray. The cavitation structures formed inside the injection holes are significantly altered by the presence of cavitation strings and are jointly responsible for up to 10% variation in the instantaneous fuel injection quantity. Extrapolation using model predictions for real-size injectors operating at realistic injection pressures indicates that cavitation strings are expected to appear within the time scales of typical injection

  11. Numerical study of cavitating flow inside a flush valve

    OpenAIRE

    BAYEUL-LAINE, Annie-Claude; Simonet, Sophie; DUTHEIL, Daniel; Caignaert, Guy

    2011-01-01

    In water supply installations, noise pollution often occurs. As a basic component of a system, a flush valve may frequently be a source of noise and vibration generated by cavitation or high turbulence levels. During valve closing or valve opening, cavitation can be a problem. In order to decrease the noise and to improve the design inside a flush valve, some experimental and numerical analyses were carried out in our laboratories. These analyses led to some improvements in the de...

  12. Coherent-Phase Monitoring Of Cavitation In Turbomachines

    Science.gov (United States)

    Jong, Jen-Yi

    1996-01-01

    Digital electronic signal-processing system analyzes outputs of accelerometers mounted on turbomachine to detect vibrations characteristic of cavitation. Designed to overcome limitation imposed by interference from discrete components. System digitally implements technique called "coherent-phase wide-band demodulation" (CPWBD), using phase-only (PO) filtering along envelope detection to search for unique coherent-phase relationship associated with cavitation and to minimize influence of large-amplitude discrete components.

  13. Cavitation Erosion of P110 Steel in Different Drilling Muds

    OpenAIRE

    Kmieć M.; Karpiński B.; Szkodo M.

    2016-01-01

    The P110 steel specimens were subjected to ultrasonic cavitation erosion in different compositions of drilling muds and surfactant additive. The test procedure was based on ASTM-G-32 standard recommendations. API 5CT-P110 steel is used for pipes in oil and gas industry. The harsh environment and high velocity of flows poses corrosive and erosive threat on materials used there. The composition of drilling fluid influences its rheological properties and thus intensity of cavitation erosion. The...

  14. Surface tension and quasi-emulsion of cavitation bubble cloud.

    Science.gov (United States)

    Bai, Lixin; Chen, Xiaoguang; Zhu, Gang; Xu, Weilin; Lin, Weijun; Wu, Pengfei; Li, Chao; Xu, Delong; Yan, Jiuchun

    2017-03-01

    A quasi-emulsion phenomenon of cavitation structure in a thin liquid layer (the thin liquid layer is trapped between a radiating surface and a hard reflector) is investigated experimentally with high-speed photography. The transformation from cloud-in-water (c/w) emulsion to water-in-cloud (w/c) emulsion is related to the increase of cavitation bubble cloud. The acoustic field in the thin liquid layer is analyzed. It is found that the liquid region has higher acoustic pressure than the cloud region. The bubbles are pushed from liquid region to cloud region by the primary Bjerknes forces. The rate of change of CSF increased with the increase of CSF. The cavitation bubbles on the surface of cavitation cloud are attracted by the cavitation bubbles inside the cloud due to secondary Bjerknes forces. The existence of surface tension on the interface of liquid region and cloud region is proved. The formation mechanism of disc-shaped liquid region and cloud region are analysed by surface tension and incompressibility of cavitation bubble cloud. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Promotion of Cultural Heritage in Batangas and Cavite

    Directory of Open Access Journals (Sweden)

    Dr. Dexter R. Buted

    2014-06-01

    Full Text Available – The study aimed to identify the commonly visited cultural heritage sites in Batangas and Cavite; to assess the cultural heritage sites in Batangas and Cavite in terms of physical, social and economic aspects; and to determine existing promotional patterns of Batangas and Cavite. Descriptive type of research was utilized in the study. Results showed that the most visited cultural heritage attraction in Taal, Batangas was Basilica of St. Martin de Tours while in Maragondon, Cavite the most visited was Andres Bonifacio Trial House . Blogs, Websites and Facebook are mostly used by the municipality of Taal in promoting their cultural heritage sites. While Cavite sticks to always using leaflets/flyers, brochures as their promotional materials. Cultural heritage sites in both Taal and Maragondon were perceived to have positive results in the assessments based on different aspects such as physical, social and economic aspects. The promotional materials of Taal and Maragondon are often used. A proposed plan of action was made to promote cultural attraction in Maragondon, Cavite and Taal, Batangas.

  16. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Science.gov (United States)

    Baran, G.; Catana, I.; Magheti, I.; Safta, C. A.; Savu, M.

    2010-08-01

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  17. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Baran, G; Safta, C A [Department of Hydraulic and Hydraulic Machineries, University Politehnica of Bucharest, 313 Splaiul Independentei, Bucharest, 060042 (Romania); Catana, I [Department of Control and Computer Science, University Politehnica of Bucharest (Romania); Magheti, I; Savu, M, E-mail: baran_gheorghe@yahoo.co.u [Department of Mechanical Engineering, University Politehnica of Bucharest (Romania)

    2010-08-15

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  18. Cavitation modeling for steady-state CFD simulations

    Science.gov (United States)

    Hanimann, L.; Mangani, L.; Casartelli, E.; Widmer, M.

    2016-11-01

    Cavitation in hydraulic turbomachines is an important phenomenon to be considered for performance predictions. Correct analysis of the cavitation onset and its effect on the flow field while diminishing the pressure level need therefore to be investigated. Even if cavitation often appears as an unsteady phenomenon, the capability to compute it in a steady state formulation for the design and assessment phase in the product development process is very useful for the engineer. In the present paper the development and corresponding application of a steady state CFD solver is presented, based on the open source toolbox OpenFOAM®. In the first part a review of different cavitation models is presented. Adopting the mixture-type cavitation approach, various models are investigated and developed in a steady state CFD RANS solver. Particular attention is given to the coupling between cavitation and turbulence models as well as on the underlying numerical procedure, especially the integration in the pressure- correction step of pressure-based solvers, which plays an important role in the stability of the procedure. The performance of the proposed model is initially assessed on simple cases available in the open literature. In a second step results for different applications are presented, ranging from airfoils to pumps.

  19. Unveiling the physical mechanism behind pistol shrimp cavitation.

    Science.gov (United States)

    Koukouvinis, Phoevos; Bruecker, Christoph; Gavaises, Manolis

    2017-10-25

    Snapping shrimps use a special shaped claw to generate a cavitating high speed water jet. Cavitation formed in this way, may be used for hunting/stunning prey and communication. The present work is a novel computational effort to provide insight on the mechanisms of cavitation formation during the claw closure. The geometry of the claw used here is a simplified claw model, based on prior experimental work. Techniques, such as Immersed Boundary and Homogenous Equilibrium Model (HEM), are employed to describe the claw motion and cavitating flow field respectively. The simulation methodology has been validated against prior experimental work and is applied here for claw closure at realistic conditions. Simulations show that during claw closure, a high velocity jet forms, inducing vortex roll-up around it. If the closure speed is high enough, the intensity of the swirling motion is enough to produce strong depressurization in the vortex core, leading to the formation of a cavitation ring. The cavitation ring moves along the jet axis and, soon after its formation, collapses and rebounds, producing high pressure pulses.

  20. Cavitation studies on whole Ricinus plants by acoustic detection.

    Science.gov (United States)

    Milburn, J A

    1973-12-01

    Acoustic detection has been used to investigate the incidence of cavitation in whole potted Ricinus plants subjected to water stress by withholding water. Cavitation proceeded rather slowly and was detectable before and during wilting. Techniques which restricted water uptake more drastically such as root cooling or overlapping cuts induced more rapid "click" production and wilting; a response already described for excised leaves. When water stress was removed by rewatering, or rewarming a cooled root system, cavitation soon ceased. This response was more sluggish of over-delayed.Cavitation in aging leaves on well watered plants has also been examined. Despite the onset of senescence over many days there was no evidence that dry patches, which often develop extensively, are a consequence of water shortage induced by xylem blockage. Leaves, falling naturally by abscission in still air, were often remarkably turgid with water potentials similar to those of healthy attached leaves. Only after losing water was cavitation apparent, as usual for excised mature leaves. Sometimes more persistent leaves did cavitate in situ, just before abscission, showing that in normal leaves xylem blockage can occasionally precede leaf fall by several hours.

  1. Pulse-Inversion Subharmonic Ultrafast Active Cavitation Imaging in Tissue Using Fast Eigenspace-Based Adaptive Beamforming and Cavitation Deconvolution.

    Science.gov (United States)

    Bai, Chen; Xu, Shanshan; Duan, Junbo; Jing, Bowen; Yang, Miao; Wan, Mingxi

    2017-08-01

    Pulse-inversion subharmonic (PISH) imaging can display information relating to pure cavitation bubbles while excluding that of tissue. Although plane-wave-based ultrafast active cavitation imaging (UACI) can monitor the transient activities of cavitation bubbles, its resolution and cavitation-to-tissue ratio (CTR) are barely satisfactory but can be significantly improved by introducing eigenspace-based (ESB) adaptive beamforming. PISH and UACI are a natural combination for imaging of pure cavitation activity in tissue; however, it raises two problems: 1) the ESB beamforming is hard to implement in real time due to the enormous amount of computation associated with the covariance matrix inversion and eigendecomposition and 2) the narrowband characteristic of the subharmonic filter will incur a drastic degradation in resolution. Thus, in order to jointly address these two problems, we propose a new PISH-UACI method using novel fast ESB (F-ESB) beamforming and cavitation deconvolution for nonlinear signals. This method greatly reduces the computational complexity by using F-ESB beamforming through dimensionality reduction based on principal component analysis, while maintaining the high quality of ESB beamforming. The degraded resolution is recovered using cavitation deconvolution through a modified convolution model and compressive deconvolution. Both simulations and in vitro experiments were performed to verify the effectiveness of the proposed method. Compared with the ESB-based PISH-UACI, the entire computation of our proposed approach was reduced by 99%, while the axial resolution gain and CTR were increased by 3 times and 2 dB, respectively, confirming that satisfactory performance can be obtained for monitoring pure cavitation bubbles in tissue erosion.

  2. Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries

    Science.gov (United States)

    Dehghani, Mahdieh; Barzegari, Rasool; Tabatabai, Hosein

    2017-01-01

    Objectives: This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries. Materials and Methods: Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD) and photostimulable phosphor plate (PSP) receptors and intra-oral films were exposed with 60 and 70 kVp with parallel technique. Two observers interpreted the radiographs twice with a two-week interval using a 5-point scale. Teeth were then serially sectioned in mesiodistal direction and evaluated under a stereomicroscope (gold standard). Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. Results: Sensitivity of all three receptors for detection of enamel lesions was low (5.5–44.4%) but it was higher for dentin lesions (42.8–62.8%); PSP with 70 kVp and 0.03s exposure time had the highest sensitivity for enamel lesions, but the difference among receptors was not statistically significant (P>0.05). Sensitivity of all three receptors for detection of non-cavitated lesions was lower than that for cavitated lesions; PSP with 60 kVp and 0.07s exposure time had higher sensitivity and lower patient radiation dose for detection of cavitated and non-cavitated lesions, but the difference was not significant (P>0.05). Conclusions: Digital radiography using PSP receptor with 70 kVp is recommended to detect initial enamel caries. For detection of non-cavitated and cavitated dentin caries, PSP with 60 kVp is more appropriate. Change in kVp did not affect the diagnostic accuracy for detection of caries, and type of receptor was a more important factor. PMID:28828014

  3. Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries

    Directory of Open Access Journals (Sweden)

    Mahdieh Dehghani

    2017-02-01

    Full Text Available Objectives: This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries.Materials and Methods: Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD and photostimulable phosphor plate (PSP receptors and intra-oral films were exposed with 60 and 70 kVp with parallel technique. Two observers interpreted the radiographs twice with a two-week interval using a 5-point scale. Teeth were then serially sectioned in mesiodistal direction and evaluated under a stereomicroscope (gold standard. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.Results: Sensitivity of all three receptors for detection of enamel lesions was low (5.5-44.4% but it was higher for dentin lesions (42.8-62.8%; PSP with 70 kVp and 0.03s exposure time had the highest sensitivity for enamel lesions, but the difference among receptors was not statistically significant (P>0.05. Sensitivity of all three receptors for detection of non-cavitated lesions was lower than that for cavitated lesions; PSP with 60 kVp and 0.07s exposure time had higher sensitivity and lower patient radiation dose for detection of cavitated and non-cavitated lesions, but the difference was not significant (P>0.05.Conclusions: Digital radiography using PSP receptor with 70 kVp is recommended to detect initial enamel caries. For detection of non-cavitated and cavitated dentin caries, PSP with 60 kVp is more appropriate. Change in kVp did not affect the diagnostic accuracy for detection of caries, and type of receptor was a more important factor.Keywords: Dental Caries; Diagnostic Imaging; Radiography, Dental, Digital

  4. Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries.

    Science.gov (United States)

    Dehghani, Mahdieh; Barzegari, Rasool; Tabatabai, Hosein; Ghanea, Sahar

    2017-01-01

    This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries. Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD) and photostimulable phosphor plate (PSP) receptors and intra-oral films were exposed with 60 and 70 kVp with parallel technique. Two observers interpreted the radiographs twice with a two-week interval using a 5-point scale. Teeth were then serially sectioned in mesiodistal direction and evaluated under a stereomicroscope (gold standard). Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. Sensitivity of all three receptors for detection of enamel lesions was low (5.5-44.4%) but it was higher for dentin lesions (42.8-62.8%); PSP with 70 kVp and 0.03s exposure time had the highest sensitivity for enamel lesions, but the difference among receptors was not statistically significant (P>0.05). Sensitivity of all three receptors for detection of non-cavitated lesions was lower than that for cavitated lesions; PSP with 60 kVp and 0.07s exposure time had higher sensitivity and lower patient radiation dose for detection of cavitated and non-cavitated lesions, but the difference was not significant (P>0.05). Digital radiography using PSP receptor with 70 kVp is recommended to detect initial enamel caries. For detection of non-cavitated and cavitated dentin caries, PSP with 60 kVp is more appropriate. Change in kVp did not affect the diagnostic accuracy for detection of caries, and type of receptor was a more important factor.

  5. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    Directory of Open Access Journals (Sweden)

    Nascimento D da C

    2014-01-01

    Full Text Available Dahan da Cunha Nascimento,1,5,8 Ramires Alsamir Tibana,1,8 Franklin M Benik,2 Keila Elizabeth Fontana,3 Frederico Ribeiro Neto,8 Frederico Santos de Santana,5,8 Leopoldo Santos-Neto,4 Renato André Sousa Silva,1,5,6 Alessandro Oliveira Silva,1,7 Darlan Lopes Farias,1,7 Sandor Balsamo,4,5,8 Jonato Prestes1 1Postgraduate Program in Physical Education, Catholic University of Brasilia, Brasilia, Brazil; 2Department of Kinesiology and Sports Studies Graduate Program, Eastern Illinois University, Charleston, IL, USA; 3Faculty of Physical Education, University of Brasilia, Brasilia, Brazil; 4Graduate Program in Medical Sciences of the University of Brasilia, School of Medicine and Rheumatology Service, University Hospital of Brasilia (HUB, Brasilia, Brazil; 5Department of Physical Education, University Center Euro American University Center, Brasilia, Brazil; 6Center of Excellence in Medicine of Exercise (CEMEx, Brasilia, Brazil; 7Center University of Brasilia (UNICEUB, Brasilia, Brazil; 8Strength Training and Health Research Group (GEPEEFS, Brasilia, Brazil Introduction: Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective: This study examined the effects of a 14-week moderate intensity resistance training program (RT on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods: Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results: Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001, relative hand grip strength (P=0.032 and a decrease of systolic (P=0.001, diastolic (P=0.008, and mean blood pressure (P=0.002 when compared to pre-exercise values. In addition, these

  6. Modeling Unsteady Cavitation Effects and Dynamic Loads in Cryogenic Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — There currently are no analytical or CFD tools that can reliably predict unsteady cavitation dynamics in liquid rocket cryogenic systems. Analysis of cavitating...

  7. Research on 3D reconstruction measurement and parameter of cavitation bubble based on stereo vision

    Science.gov (United States)

    Li, Shengyong; Ai, Xiaochuan; Wu, Ronghua; Cao, Jing

    2017-02-01

    The problems caused by the cavitation bubble and caused many adverse effects on the ship propeller, hydraulic machinery and equipment. In order to research the production mechanism of cavitation bubble under different conditions, cavitation bubble zone parameter fine measurement and analysis technology is indispensable, this paper adopts a non-contact measurement method of optical autonomous construction of binocular stereo vision measurement system according to the characteristics of cavitation bubble, the texture features are not clear, transparent and difficult to obtain, 3D imaging measurement of cavitation bubble using composite dynamic lighting, and 3D reconstruction of cavitation bubble region and obtained the characteristics of more accurate parameters, test results show that the cavitation bubble characteristics of the fine technology can obtain and analyze cavitation bubble region and instability.

  8. Spatial-Temporal Hotspot Pattern Analysis of Provincial Environmental Pollution Incidents and Related Regional Sustainable Management in China in the Period 1995–2012

    Directory of Open Access Journals (Sweden)

    Lei Ding

    2015-10-01

    Full Text Available Spatial-temporal hotspot pattern analysis of environmental pollution incidents provides an indispensable source of information for the further development of incident prevention measures. In this study, the spatial-temporal patterns of environmental pollution incidents in China in the period of 1995–2012 were analyzed, using the Spatial Getis-Ord statistic and an Improved Prediction Accuracy Index (IAPI. The results show that, in this period, the occurrence of environmental incidents exhibited a dynamic growth pattern but then dropped and continued to drop after the year 2006, which was considered a crucial turning point. Not coincidentally, this corresponds to the year when the State Council issued its National Environmental Emergency Plan, and following the examination of major incidents, special actions were taken to strengthen the control of incidents and emergency responses. The results from Getis-Ord General G statistical analysis show that the spatial agglomeration phenomenon was statistically significant after 1999 and that the level of spatial agglomeration was rising, while the Getis-Ord Gi* statistical analysis reveals that environmental pollution incidents were mainly agglomerated in the Pan Yangtze River Delta and Pan Pearl River Delta regions. Accordingly, the spatial-temporal hotspot pattern based on the IAPI values at the provincial scale could be categorized into: stable hotspots, unstable hotspots, and cold-spot areas. The stable hotspots category was further divided into three subtypes: industrial distribution type, industrial transfer type, and extensive economic growth type. Finally, the corresponding measures for sustainable management were proposed: stable hotspots were classified as essential regions requiring the immediate prevention and control of environmental pollution incidents; unstable hotspots were characterized by their need for ongoing and continual prevention measures, and cold-spots were those areas that

  9. Shock waves from nonspherical cavitation bubbles

    Science.gov (United States)

    Supponen, Outi; Obreschkow, Danail; Kobel, Philippe; Tinguely, Marc; Dorsaz, Nicolas; Farhat, Mohamed

    2017-09-01

    We present detailed observations of the shock waves emitted at the collapse of single cavitation bubbles using simultaneous time-resolved shadowgraphy and hydrophone pressure measurements. The geometry of the bubbles is systematically varied from spherical to very nonspherical by decreasing their distance to a free or rigid surface or by modulating the gravity-induced pressure gradient aboard parabolic flights. The nonspherical collapse produces multiple shocks that are clearly associated with different processes, such as the jet impact and the individual collapses of the distinct bubble segments. For bubbles collapsing near a free surface, the energy and timing of each shock are measured separately as a function of the anisotropy parameter ζ , which represents the dimensionless equivalent of the Kelvin impulse. For a given source of bubble deformation (free surface, rigid surface, or gravity), the normalized shock energy depends only on ζ , irrespective of the bubble radius R0 and driving pressure Δ p . Based on this finding, we develop a predictive framework for the peak pressure and energy of shock waves from nonspherical bubble collapses. Combining statistical analysis of the experimental data with theoretical derivations, we find that the shock peak pressures can be estimated as jet impact-induced hammer pressures, expressed as ph=0.45 (ρc2Δ p ) 1 /2ζ-1 at ζ >10-3 . The same approach is found to explain the shock energy decreasing as a function of ζ-2 /3.

  10. Supersonic microjets induced by hemispherical cavitation bubbles

    Science.gov (United States)

    Gonzalez-Avila, Roberto; Song, Chaolong; Ohl, Claus-Dieter

    2014-11-01

    In recent years methods to produce fast microjets have received significant attention due to their potential to be employed in needle-free injection devices that can provide mass inoculation. In this talk we present a novel technique capable of producing jets that can reach up to 400 m/s. The jets are produced by a device that consists only of two electrodes on a plastic substrate and a tapered hole of 13 ~ 20 μm between them. A short pulse of electric current is applied to the electrodes, then a spark bridges between the electrodes creating a cavitation bubble. Liquid is accelerated through the hole during the expansion and collapse of the bubble producing two separate jets. We found that as the exit velocity of the jet increases the jets become unstable. The second jet exiting the hole, usually faster than the first jet exits as a spray. The effect of viscosity was also studied with silicone oils up to 100 cSt. Finally, we also demonstrate that the jets can penetrate into soft material, thus they have the potential to be used in a needle-free drug-delivery application.

  11. Numerical modeling of a two-dimensional aerated cavitation in a symmetrical venturi nozzle

    OpenAIRE

    Tomov, P; Khelladi, S; Ravelet, Florent; Sarraf, C; Bakir, F; Giroux, D

    2015-01-01

    National audience; Cavitation is a well-known physical phenomenon occurring in various technical applications. Its coupling with the aeration, is a recent technique, which allows the control of the overall effect of the cavitation. The aeration is achieved by introducing air bubbles into the flow. In order to reveal and explore the behaviour of air in the vicinity of the cavitation regions, the paper is oriented towards the physics of the colliding vapour phase in the presence of cavitation. ...

  12. Recent developments in cavitation mechanisms a guide for scientists and engineers

    CERN Document Server

    Washio, Seiichi

    2014-01-01

    How does cavitation start? Presently, the nucleus theory provides the answer to this fundamental question. However the idea of nuclei contains inaccuracies that cannot be rationalized. Recent Developments in Cavitation Mechanisms discusses the uncertainties surrounding the nucleus theory, and proposes another theory of cavitation mechanism. Characteristically, the new theory is based on recent discoveries of cavity generation phenomena in separating flows. This book consists of chapters that introduce topics such as unsoundness of cavitation nuclei, and phenomena of cavity generation on walls

  13. Gauging the likelihood of stable cavitation from ultrasound contrast agents

    Science.gov (United States)

    Bader, Kenneth B; Holland, Christy K

    2015-01-01

    The mechanical index (MI) was formulated to gauge the likelihood of adverse bioeffects from inertial cavitation. However, the MI formulation did not consider bubble activity from stable cavitation. This type of bubble activity can be readily nucleated from ultrasound contrast agents (UCAs) and has the potential to promote beneficial bioeffects. Here, the presence of stable cavitation is determined numerically by tracking the onset of subharmonic oscillations within a population of bubbles for frequencies up to 7 MHz and peak rarefactional pressures up to 3 MPa. In addition, the acoustic pressure rupture threshold of an UCA population was determined using the Marmottant model. The threshold for subharmonic emissions of optimally sized bubbles was found to be lower than the inertial cavitation threshold for all frequencies studied. The rupture thresholds of optimally sized UCAs were found to be lower than the threshold for subharmonic emissions for either single cycle or steady state acoustic excitations. Because the thresholds of both subharmonic emissions and UCA rupture are linearly dependent on frequency, an index of the form ICAV = Pr/f (where Pr is the peak rarefactional pressure in MPa and f is the frequency in MHz) was derived to gauge the likelihood of subharmonic emissions due to stable cavitation activity nucleated from UCAs. PMID:23221109

  14. Numerical Calculation on Cavitation Pressure Pulsation in Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Weidong Shi

    2014-02-01

    Full Text Available In order to study the internal flow in centrifugal pump when cavitation occurs, numerical calculation of the unsteady flow field in the WP7 automobile centrifugal pump is conducted based on the Navier-Stokes equations with the RNG k – ε turbulence model and Zwart-Gerber-Belamri cavitation model. The distributions of bubble volume fraction and pressure pulsation laws in the pump are analyzed when cavitation occurs. The conclusions are as follows: the bubble volume fraction is larger on the suction side of impeller blade near the inlet edge, which is consistent with the low-pressure region distribution. Bubble volume is determined by the growth rate and collapse rate of every bubble in the bubble group. The cavitation degree changes over time with the impeller rotation and the bubble growth and collapse coexist in the impeller flow channels. The main pulsation results from the cyclic and static coupling between the impeller and the tongue, while the fluctuating amplitude is increased by the cavitation.

  15. Numerical Modeling of Unsteady Cavitating Flows around a Stationary Hydrofoil

    Directory of Open Access Journals (Sweden)

    Antoine Ducoin

    2012-01-01

    Full Text Available The objective of this paper is to evaluate the predictive capability of three popular transport equation-based cavitation models for the simulations of partial sheet cavitation and unsteady sheet/cloud cavitating flows around a stationary NACA66 hydrofoil. The 2D calculations are performed by solving the Reynolds-averaged Navier-Stokes equation using the CFD solver CFX with the k-ω SST turbulence model. The local compressibility effect is considered using a local density correction for the turbulent eddy viscosity. The calculations are validated with experiments conducted in a cavitation tunnel at the French Naval Academy. The hydrofoil has a fixed angle of attack of α=6° with a Reynolds number of Re = 750,000 at different cavitation numbers σ. Without the density modification, over-prediction of the turbulent viscosity near the cavity closure reduces the cavity length and modifies the cavity shedding characteristics. The results show that it is important to capture both the mean and fluctuating values of the hydrodynamic coefficients because (1 the high amplitude of the fluctuations is critical to capturing the extremes of the loads to ensure structural safety and (2 the need to capture the frequency of the fluctuations, to avoid unwanted noise, vibrations, and accelerated fatigue issues.

  16. Numerical analysis for cavitation flow of marine propeller

    Science.gov (United States)

    Tauviqirrahman, Mohammad; Muchammad, Ismail, Rifky; Jamari, J.

    2015-12-01

    Concerning the environmental issue and the increase of fuel price, optimizing the fuel consumption has been recently an important subject in all industries. In marine industries one of the ways to decrease the energy consumption was by reducing the presence of cavitation on marine propeller blades. This will give a higher propulsive efficiency. This paper provides an investigation into the influence of the cavitation on a hydrodynamic performance around the propeller based on numerical method. Hydrofoil representing the blade form of propeller was of particular of interest. Two types of cavitation model were investigated with respect to the accuracy of the result and the effectiveness of the method. The results include the hydrodynamic characteristics of cavitation phenomenon like lift/drag variation with respect to the cavity extent. It was found that a high accuracy and low computational time is achieved when the cavitation model of Zwart-Gerber-Belamri is used. The interesting outcome of this study is that the results can be used as a good evaluation tool for high marine propeller performance.

  17. Fluid dynamics of acoustic and hydrodynamic cavitation in hydraulic power systems.

    Science.gov (United States)

    Ferrari, A

    2017-03-01

    Cavitation is the transition from a liquid to a vapour phase, due to a drop in pressure to the level of the vapour tension of the fluid. Two kinds of cavitation have been reviewed here: acoustic cavitation and hydrodynamic cavitation. As acoustic cavitation in engineering systems is related to the propagation of waves through a region subjected to liquid vaporization, the available expressions of the sound speed are discussed. One of the main effects of hydrodynamic cavitation in the nozzles and orifices of hydraulic power systems is a reduction in flow permeability. Different discharge coefficient formulae are analysed in this paper: the Reynolds number and the cavitation number result to be the key fluid dynamical parameters for liquid and cavitating flows, respectively. The latest advances in the characterization of different cavitation regimes in a nozzle, as the cavitation number reduces, are presented. The physical cause of choked flows is explained, and an analogy between cavitation and supersonic aerodynamic flows is proposed. The main approaches to cavitation modelling in hydraulic power systems are also reviewed: these are divided into homogeneous-mixture and two-phase models. The homogeneous-mixture models are further subdivided into barotropic and baroclinic models. The advantages and disadvantages of an implementation of the complete Rayleigh-Plesset equation are examined.

  18. PENGARUH PROFIT MARGIN, ASSETS TURNOVER DAN LEVERAGE TERHADAP SUSTAINABLE GROWTH RATE PADA PERUSAHAAN SEKTOR JASA YANG TERDAFTAR DI BURSA EFEK INDONESIA PERIODE 2010-2012

    Directory of Open Access Journals (Sweden)

    Arim Nasim

    2015-04-01

    Full Text Available This study aims to determine the effect of Profit Margin, Assets Turnover and Leverage on Sustainable Growth Rate. The variables used are profit margin, asset turnover and leverage as independent variable and sustainable growth rate as dependent variable. This study also aims to describe the state of profit margin projected by Net Profit Margin (NPM, asset turnover proxied by Total Assets Turnover (TATO, leverage which is proxied by Debt to Equity Ratio (DER and Sustainable Growth Rate (SGR Service sector. This research was conducted on service sector companies listed in Indonesia Stock Exchange 2010-2012.Data obtained from website Bursa Efek Indonesia.Teknik data analysis used is multiple linear regression and use t-statistics to test the influence of each independent variable to variable Dependent partially.Previously done classical assumption test that includes data normality test, multicolinierity test, heteroskedastisitas test and autocorrelation test.Based on data normality test, multicolinierity test, heteroscedasticity test and autocorrelation test did not found any variables that deviate from the classical assumption.From the results of research Shows that profit margin positively affect sustainable growth rate, asset turnover have positive effect to sustainable growth rate, and leverage have positive effect to sustainable growth rate.

  19. Compressible Turbulent Flow Numerical Simulations of Tip Vortex Cavitation

    Science.gov (United States)

    Khatami, F.; van der Weide, E.; Hoeijmakers, H.

    2015-12-01

    For an elliptic Arndt's hydrofoil numerical simulations of vortex cavitation are presented. An equilibrium cavitation model is employed. This single-fluid model assumes local thermodynamic and mechanical equilibrium in the mixture region of the flow, is employed. Furthermore, for characterizing the thermodynamic state of the system, precomputed multiphase thermodynamic tables containing data for the appropriate equations of state for each of the phases are used and a fast, accurate, and efficient look-up approach is employed for interpolating the data. The numerical simulations are carried out using the Unsteady Reynolds-Averaged Navier-Stokes (URANS) equations for compressible flow. The URANS equations of motion are discretized using an finite volume method for unstructured grids. The numerical simulations clearly show the formation of the tip vortex cavitation in the flow about the elliptic hydrofoil.

  20. Radiographic display of carious lesions and cavitation in approximal surfaces

    DEFF Research Database (Denmark)

    Wenzel, Ann

    2014-01-01

    Abstract Background. Treatment strategies have changed with efforts on arresting carious lesions suspected to have an intact surface sparing operative treatment for cavitated lesions. Radiography is still the most recommended adjunct method in the diagnosis of clinically inaccessible approximal...... surfaces. Bitewing radiography. The major drawback of bitewing radiography for caries diagnosis is that the clinical state of the surface cannot be determined; i.e. if cavitation has developed or the demineralized surface is still intact. Based on studies of the relationship between radiographic lesion...... depth and clinical cavitation in approximal surfaces, a threshold for operative treatment decision has been suggested when a lesion is observed radiographically more than one-third into dentine. However, the results from previous studies are contradictory and the majority of studies are ∼25 years old...

  1. Cavitation Erosion of Cermet-Coated Aluminium Bronzes

    Directory of Open Access Journals (Sweden)

    Ion Mitelea

    2016-03-01

    Full Text Available The cavitation erosion resistance of CuAl10Ni5Fe2.5Mn1 following plasma spraying with Al2O3·30(Ni20Al powder and laser re-melting was analyzed in view of possible improvements of the lifetime of components used in hydraulic environments. The cavitation erosion resistance was substantially improved compared with the one of the base material. The thickness of the re-melted layer was in the range of several hundred micrometers, with a surface microhardness increasing from 250 to 420 HV 0.2. Compositional, structural, and microstructural explorations showed that the microstructure of the re-melted and homogenized layer, consisting of a cubic Al2O3 matrix with dispersed Ni-based solid solution is associated with the hardness increase and consequently with the improvement of the cavitation erosion resistance.

  2. Numerical Study on Characteristics of 3D Cavitating Hydrofoil

    Directory of Open Access Journals (Sweden)

    Cao Wei

    2015-01-01

    Full Text Available The commercial software ANSYS CFX, APDL and Workbench are applied for modeling the hydrodynamic and structural interactions and characteristics of an elastic hydrofoil by means of a two-way FSI method. The SST (Shear Stress Transport turbulence model and the simplified Rayleigh-Plesset equations are employed for the cavitating flow simulation. Both CFX and APDL solvers are set to be transient. The fluid and solid computational domains are sequentially solved to simulate the interactions between the hydrofoil and the cavitating flow. The results show that the difference in stiffness of common metal materials has trifling effects on hydrofoil performance. But variations in cavitation number and angle of attack will dramatically affect the hydrodynamic and structural interactions and characteristics.

  3. Numerical simulation of study and unsteady sheet cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Schnerr, G.H.; Spengler, C. (Karlsruhe Univ. (T.H.) (Germany). Abt. Stroemungsmaschinen)

    1998-01-01

    The aim of the work is to provide an efficient code to simulate developed sheet cavitation including the unsteady behavior at the end of the sheet. The vapor region is calculated directly by using a 'compressible system' of equations. To simulate the liquid phase an 'incompressible system' of equations is used. The numerical method is based on an extended method of artificial compressibility which allows the simultaneous calculation of compressible and incompressible flows. To verify the code a first cavitating result of the inviscid flow around a NACA0012 hydrofoil at a Mach number M=0.1, an angle of attack [alpha]=4 , and a cavitation number [sigma]=1.0 is presented. (orig.)

  4. Numerical simulation of study and unsteady sheet cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Schnerr, G.H.; Spengler, C. [Karlsruhe Univ. (T.H.) (Germany). Abt. Stroemungsmaschinen

    1998-12-31

    The aim of the work is to provide an efficient code to simulate developed sheet cavitation including the unsteady behavior at the end of the sheet. The vapor region is calculated directly by using a `compressible system` of equations. To simulate the liquid phase an `incompressible system` of equations is used. The numerical method is based on an extended method of artificial compressibility which allows the simultaneous calculation of compressible and incompressible flows. To verify the code a first cavitating result of the inviscid flow around a NACA0012 hydrofoil at a Mach number M=0.1, an angle of attack {alpha}=4 , and a cavitation number {sigma}=1.0 is presented. (orig.)

  5. Cavitation erosion: Using the target material as a pressure sensor

    Science.gov (United States)

    Roy, Samir Chandra; Franc, Jean-Pierre; Fivel, Marc

    2015-10-01

    Numerical prediction of mass loss due to cavitation erosion requires the knowledge of the hydrodynamic impact loads generated by cavitation bubble collapses. Experimental measurements of such impact loads using conventional pressure sensors are not reliable (if not impossible) due to the micron size and the very small duration of the loading. In this paper, a new method to estimate these loading conditions is proposed based on cavitation pitting tests and an iterative inverse finite element modeling. The principle of the method is as follows. First, numerous pits corresponding to localized plastically deformed regions are identified from a cavitation test performed in a dedicated tunnel. Then each pit is numerically reproduced by finite element simulations of the material response to a representative Gaussian pressure field supposed to mimic a single bubble collapse. This gives the size and pressure distribution of the bubble impacts. The prime objective of this study is to find out if the target material itself could be used as a pressure sensor or not, i.e., if the cavitation pits left on the surface of the tested specimen could provide the characteristics of the cavitating flow in terms of pressure fields independently of the target material. Pitting tests were done on three materials, namely, 7075 Aluminum alloy (Al-7075), 2205 duplex stainless steel (A-2205), and Nickel-Aluminum Bronze (NAB) at three different flow conditions and the impact loads have been estimated for each identified pit. Very interestingly, a statistical analysis shows that the estimated impact loads are material independent at all flow conditions, provided the material properties are characterized properly. It is also shown that for some materials, the constitutive parameters obtained from compression tests are not satisfactory.

  6. Model test and CFD calculation of a cavitating bulb turbine

    Energy Technology Data Exchange (ETDEWEB)

    Necker, J; Aschenbrenner, T, E-mail: joerg.necker@voith.co [Voith Hydro Holding GmbH and Co. KG Alexanderstrasse 11, 89522 Heidenheim (Germany)

    2010-08-15

    The flow in a horizontal shaft bulb turbine is calculated as a two-phase flow with a commercial Computational Fluid Dynamics (CFD-)-code including cavitation model. The results are compared with experimental results achieved at a closed loop test rig for model turbines. On the model test rig, for a certain operating point (i.e. volume flow, net head, blade angle, guide vane opening) the pressure behind the turbine is lowered (i.e. the Thoma-coefficient {sigma} is lowered) and the efficiency of the turbine is recorded. The measured values can be depicted in a so-called {sigma}-break curve or {eta}- {sigma}-diagram. Usually, the efficiency is independent of the Thoma-coefficient up to a certain value. When lowering the Thoma-coefficient below this value the efficiency will drop rapidly. Visual observations of the different cavitation conditions complete the experiment. In analogy, several calculations are done for different Thoma-coefficients {sigma}and the corresponding hydraulic losses of the runner are evaluated quantitatively. For a low {sigma}-value showing in the experiment significant efficiency loss, the the change of volume flow in the experiment was simulated. Besides, the fraction of water vapour as an indication of the size of the cavitation cavity is analyzed qualitatively. The experimentally and the numerically obtained results are compared and show a good agreement. Especially the drop in efficiency can be calculated with satisfying accuracy. This drop in efficiency is of high practical importance since it is one criterion to determine the admissible cavitation in a bulb-turbine. The visual impression of the cavitation in the CFD-analysis is well in accordance with the observed cavitation bubbles recorded on sketches and/or photographs.

  7. PREFACE: 9th International Symposium on Cavitation (CAV2015)

    Science.gov (United States)

    Farhat, M.; Müller, A.

    2015-12-01

    It is our pleasure and privilege to welcome all the participants of the 9th International Symposium on Cavitation (CAV2015) to Lausanne. Since its initiation in 1986 in Sendai, Japan, the CAV symposium has grown to become the world's foremost event dedicated to cavitation. Hosted by EPFL (Ecole Polytechnique Fédérale de Lausanne) and staged at the SwissTech Convention Center, CAV2015 is a unique opportunity to exchange with leading scientists and industry experts about the latest advances in theoretical modelling, numerical simulation and experimentation related to cavitation phenomena with a special emphasis on practical applications. The topics covered by CAV2015 include cavitation in ¬fluid machinery and fuel systems, bubble dynamics, cavitation erosion, advanced numerical simulation, sonochemistery, biomedicine and experimental techniques. CAV2015 will also host an exhibition of leading providers of state of the art measurement equipment, including high-speed imaging systems, non-intrusive velocimetry, pressure sensors, as well as numerical solvers. We have accepted over 190 papers, which will be presented in four parallel sessions. The proceedings will appear in the open access Journal of Physics: Conference Series (JPCS), which is part of the IOP Conference Series. All published papers are fully citable and upon publication will be free to download in perpetuity. We would like to thank all the reviewers for their great help during the selection process. We will also propose six plenary speakers to highlight cavitation issues in different fields. Finally, we would like to warmly thank our sponsors for their valuable support and the local Organizing Committee for the efforts in setting up this important event. We look forward to seeing you in Lausanne!

  8. Cavitation Bubble Nucleation by Energetic Particles

    Energy Technology Data Exchange (ETDEWEB)

    West, C.D.

    1998-12-01

    In the early sixties, experimental measurements using a bubble chamber confirmed quantitatively the thermal spike theory of bubble nucleation by energetic particles: the energy of the slow, heavy alpha decay recoils used in those experiments matched the calculated bubble nucleation energy to within a few percent. It was a triumph, but was soon to be followed by a puzzle. Within a couple of years, experiments on similar liquids, but well below their normal boiling points, placed under tensile stress showed that the calculated bubble nucleation energy was an order of magnitude less than the recoil energy. Why should the theory work so well in the one case and so badly in the other? How did the liquid, or the recoil particle, "know" the difference between the two experiments? Another mathematical model of the same physical process, introduced in 1967, showed qualitatively why different analyses would be needed for liquids with high and low vapor pressures under positive or negative pressures. But, the quantitative agreement between the calculated nucleation energy and the recoil energy was still poor--the former being smaller by a factor of two to three. In this report, the 1967 analysis is extended and refined: the qualitative understanding of the difference between positive and negative pressure nucleation, "boiling" and "cavitation" respectively, is retained, and agreement between the negative pressure calculated to be needed for nucleation and the energy calculated to be available is much improved. A plot of the calculated negative pressure needed to induce bubble formation against the measured value now has a slope of 1.0, although there is still considerable scatter in the individual points.

  9. Cavitation in ultrasound and shockwave therapy

    Science.gov (United States)

    Colonius, Tim

    2014-11-01

    Acoustic waves, especially high-intensity ultrasound and shock waves, are used for medical imaging and intra- and extra-corporeal manipulation of cells, tissue, and urinary calculi. Waves are currently used to treat kidney stone disease, plantar fasciitis, and bone nonunion, and they are being investigated as a technique to ablate cancer tumors and mediate drug delivery. In many applications, acoustic waves induce the expansion and collapse of preexisting or newly cavitating bubbles whose presence can either mediate the generation of localized stresses or lead to collateral damage, depending on how effectively they can be controlled. We describe efforts aimed at simulating the collapse of bubbles, both individually and in clusters, with the aim to characterize the induced mechanical stresses and strains. To simulate collapse of one or a few bubbles, compressible Euler and Navier-Stokes simulations of multi-component materials are performed with WENO-based shock and interface capturing schemes. Repetitive insonification generates numerous bubbles that are difficult to resolve numerically. Such clouds are also important in traditional engineering applications such as caveating hydrofoils. Models that incorporate the dynamics of an unresolved dispersed phase consisting of the bubble cloud are also developed. The results of several model problems including bubble collapse near rigid surfaces, bubble collapse near compliant surfaces and in small capillaries are analyzed. The results are processed to determine the potential for micron-sized preexisting gas bubbles to damage capillaries. The translation of the fundamental fluid dynamics into improvements in the design and clinical application of shockwave lithotripters will be discussed. NIH Grant PO1-DK043881.

  10. Characterization of Axial Inducer Cavitation Instabilities via High Speed Video Recordings

    Science.gov (United States)

    Arellano, Patrick; Peneda, Marinelle; Ferguson, Thomas; Zoladz, Thomas

    2011-01-01

    Sub-scale water tests were undertaken to assess the viability of utilizing high resolution, high frame-rate digital video recordings of a liquid rocket engine turbopump axial inducer to characterize cavitation instabilities. These high speed video (HSV) images of various cavitation phenomena, including higher order cavitation, rotating cavitation, alternating blade cavitation, and asymmetric cavitation, as well as non-cavitating flows for comparison, were recorded from various orientations through an acrylic tunnel using one and two cameras at digital recording rates ranging from 6,000 to 15,700 frames per second. The physical characteristics of these cavitation forms, including the mechanisms that define the cavitation frequency, were identified. Additionally, these images showed how the cavitation forms changed and transitioned from one type (tip vortex) to another (sheet cavitation) as the inducer boundary conditions (inlet pressures) were changed. Image processing techniques were developed which tracked the formation and collapse of cavitating fluid in a specified target area, both in the temporal and frequency domains, in order to characterize the cavitation instability frequency. The accuracy of the analysis techniques was found to be very dependent on target size for higher order cavitation, but much less so for the other phenomena. Tunnel-mounted piezoelectric, dynamic pressure transducers were present throughout these tests and were used as references in correlating the results obtained by image processing. Results showed good agreement between image processing and dynamic pressure spectral data. The test set-up, test program, and test results including H-Q and suction performance, dynamic environment and cavitation characterization, and image processing techniques and results will be discussed.

  11. Relationship between cavitation and loss of echogenicity from ultrasound contrast agents

    Science.gov (United States)

    Radhakrishnan, Kirthi; Bader, Kenneth B; Haworth, Kevin J; Kopechek, Jonathan A; Raymond, Jason L; Huang, Shao-Ling; McPherson, David D; Holland, Christy K

    2014-01-01

    Ultrasound contrast agents (UCAs) have the potential to nucleate cavitation and promote both beneficial and deleterious bioeffects in vivo. Previous studies have elucidated the pulse-duration dependent pressure amplitude threshold for rapid loss of echogenicity due to UCA fragmentation. Previous studies have demonstrated that UCA fragmentation was concomitant with inertial cavitation. The purpose of this study was to evaluate the relationship between stable and inertial cavitation thresholds and loss of echogenicity of UCAs as a function of pulse duration. Determining the relationship between cavitation thresholds and loss of echogenicity of UCAs would enable monitoring of cavitation based upon the on-screen echogenicity in clinical applications. Two lipid-shelled UCAs, echogenic liposomes (ELIP) and Definity®, were insonified by a clinical ultrasound scanner in duplex spectral Doppler mode at four pulse durations (“sample volumes”) in both a static system and a flow system. Cavitation emissions from the UCAs insonified by Doppler pulses were recorded using a passive cavitation detection system and stable and inertial cavitation thresholds ascertained. Loss of echogenicity from ELIP and Definity® was assessed within regions of interest on B-mode images. A numerical model based on UCA rupture predicted the functional form of the loss of echogenicity from ELIP and Definity®. Stable and inertial cavitation thresholds were found to have a weak dependence on pulse duration. Stable cavitation thresholds were lower than inertial cavitation thresholds. The power of cavitation emissions was an exponential function of the loss of echogenicity over the investigated range of acoustic pressures. Both ELIP and Definity® lost more than 80% echogenicity before the onset of stable or inertial cavitation. Once this level of echogenicity loss occurred, both stable and inertial cavitation were detected in the physiologic flow phantom. These results imply that stable and

  12. NON - OPERATIVE TREATMENT OF NON - CAVITATED APPROXIMAL CARIOUS LESIONS OF PERMANENT CHIDREN’S TEETH.

    Directory of Open Access Journals (Sweden)

    Rossiza I. Kabakchieva

    2014-10-01

    Full Text Available Aim: To apply and follow up in clinical conditions the success rate of microinvasive technique of infiltration with low viscosity resin ICON® (DMG of non cavitated approximal caries lesions of permanent children's teeth for a period of one year. Material and methods: The study included 18 children aged 7-16 years. They were divided into two groups - children with medium and high caries risk. The survey include 20 teeth with approximal non-cavitated enamel lesions up to the outer third of dentin (E1, E2, D1 – according to the manufacturer’s instructions of ICON®. The size of the lesions was determined using bitewing radiographs and the activity - by Papilla Bleeding Index. The clinical application of the infiltr+ant (ICON® Caries Infiltrant Proximal, DMG was conducted according to the manufacturer's instructions. Bitewing radiographs were made at 6 and 12 months after infiltration in order to evaluate the success of the method. A test of the difference between two relative proportions and alternative test for analysis of the results were used. Results: Our study confirm the hypothesis that this method of infiltration is equally successful for permanent teeth in patients with moderate caries risk as well as those at high caries risk. Conclusion: This study is the first survey regarding the success of the application of ICON® for treatment of non-cavitated approximal carious lesions in permanent dentition of children in the country. Research in this direction should continue in order to increase the conviction that caries can be controlled and arrested in its earliest stages.

  13. Effects of Temperature on the Histotripsy Intrinsic Threshold for Cavitation.

    Science.gov (United States)

    Vlaisavljevich, Eli; Xu, Zhen; Maxwell, Adam; Mancia, Lauren; Zhang, Xi; Lin, Kuang-Wei; Duryea, Alexander; Sukovich, Jonathan; Hall, Tim; Johnsen, Eric; Cain, Charles

    2016-05-10

    Histotripsy is an ultrasound ablation method that depends on the initiation of a dense cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated that a cavitation cloud can be formed by a single acoustic pulse with one high amplitude negative cycle, when the negative pressure amplitude exceeds a threshold intrinsic to the medium. The intrinsic thresholds in soft tissues and tissue phantoms that are water-based are similar to the intrinsic threshold of water over an experimentally verified frequency range of 0.3-3 MHz. Previous work studying the histotripsy intrinsic threshold has been limited to experiments performed at room temperature (~20°C). In this study, we investigate the effects of temperature on the histotripsy intrinsic threshold in water, which is essential to accurately predict the intrinsic thresholds expected over the full range of in vivo therapeutic temperatures. Based on previous work studying the histotripsy intrinsic threshold and classical nucleation theory, we hypothesize that the intrinsic threshold will decrease with increasing temperature. To test this hypothesis, the intrinsic threshold in water was investigated both experimentally and theoretically. The probability of generating cavitation bubbles was measured by applying a single pulse with one high amplitude negative cycle at 1 MHz to distilled, degassed water at temperatures ranging from 10°C-90°C. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results indicate that the intrinsic threshold (the negative pressure at which the cavitation probability=0.5) significantly decreases with increasing temperature, showing a nearly linear decreasing trend from 29.8±0.4 MPa at 10˚C to 14.9±1.4 MPa at 90˚C. Overall, the results of this study support our hypothesis that the intrinsic threshold is highly dependent upon the temperature

  14. Controlled permeation of cell membrane by single bubble acoustic cavitation

    Science.gov (United States)

    Zhou, Y.; Yang, K.; Cui, J.; Ye, J. Y.; Deng, C. X.

    2011-01-01

    Sonoporation is the membrane disruption generated by ultrasound and has been exploited as a non-viral strategy for drug and gene delivery. Acoustic cavitation of microbubbles has been recognized to play an important role in sonoporation. However, due to the lack of adequate techniques for precise control of cavitation activities and real-time assessment of the resulting sub-micron process of sonoporation, limited knowledge has been available regarding the detail processes and correlation of cavitation with membrane disruption at the single cell level. In the current study, we developed a combined approach including optical, acoustic, and electrophysiological techniques to enable synchronized manipulation, imaging, and measurement of cavitation of single bubbles and the resulting cell membrane disruption in real-time. Using a self-focused femtosecond laser and high frequency (7.44 MHz) pulses, a single microbubble was generated and positioned at a desired distance from the membrane of a Xenopus oocyte. Cavitation of the bubble was achieved by applying a low frequency (1.5 MHz) ultrasound pulse (duration 13.3 or 40 µs) to induce bubble collapse. Disruption of the cell membrane was assessed by the increase in the transmembrane current (TMC) of the cell under voltage clamp. Simultaneous high-speed bright field imaging of cavitation and measurements of the TMC were obtained to correlate the ultrasound-generated bubble activities with the cell membrane poration. The change in membrane permeability was directly associated with the formation of a sub-micrometer pore from a local membrane rupture generated by bubble collapse or bubble compression depending on ultrasound amplitude and duration. The impact of the bubble collapse on membrane permeation decreased rapidly with increasing distance (D) between the bubble (diameter d) and the cell membrane. The effective range of cavitation impact on membrane poration was determined to be D/d = 0.75. The maximum mean radius of the

  15. Computation of Cavitating Flows in a Diesel Injector

    Science.gov (United States)

    Echouchene, F.; Belmabrouk, H.

    2010-11-01

    The flow inside Diesel injectors is important because of its effect on the spray and the atomization process in the combustion chamber. Due to huge stress at the orifice entrance, cavitation occurs in high-pressure Diesel injectors. In this study, we investigate numerically the cavitating steady flow in a Diesel injector. The mixture model based on a single fluid and the standard k-e turbulence model are used to simulate the multiphase turbulent flow. The effects of some geometrical parameters on both the discharge coefficient and the vapor fraction are presented.

  16. Cavitation nuclei in water exposed to transient pressures

    DEFF Research Database (Denmark)

    Andersen, Anders Peter; Mørch, Knud Aage

    2015-01-01

    A model of skin-stabilized interfacial cavitation nuclei and their response to tensile and compressive stressing is presented. The model is evaluated in relation to experimental tensile strength results for water at rest at the bottom of an open water-filled container at atmospheric pressure...... and room temperature. These results are obtained by recording the initial growth of cavities generated by a short tensile pulse applied to the bottom of the container. It is found that the cavitation nuclei shift their tensile strength depending on their pressure history. Static pressurization...

  17. 3D analyses of cavitation instabilities accounting for plastic anisotropy

    DEFF Research Database (Denmark)

    Legarth, Brian Nyvang; Tvergaard, Viggo

    2010-01-01

    Full three dimensional cell model analyses are carried out for a solid containing a single small void, in order to determine the critical stress levels for the occurrence of cavitation instabilities. The material models applied are elastic‐viscoplastic, with a small rate‐hardening exponent...... that the quasi‐static solution is well approximated. A special procedure is used to strongly reduce the loading rate a little before the instability occurs. It is found that plastic anisotropy has a significant effect on the level of the critical stress for cavitation instabilities....

  18. A Numerical Study of Cavitation Inception in Complex Flow Fields

    Science.gov (United States)

    2007-12-01

    Acta Acustica United with Acustica , Vol. 93, pp. 555-565, 2007. 9. “Numerical Study of Cavitation Inception Due to Vortex/Vortex Interaction in a...Chahine, G.L. “Modeling of Bubble Generated Noise in Tip Vortex Cavitation Inception,” Acta Acustica United with Acustica , Vol. 93, pp. 555-565, 2007. 1...Capture and Noise of Spheri- cal Nuclei in the Presence of the Tip Vortex of Hydrofoils and Propellers,’’ Acustica , 68, pp. 1–14. @10# Hsiao, C.-T

  19. Sediment and Cavitation Erosion Studies through Dam Tunnels

    Directory of Open Access Journals (Sweden)

    Muhammad Abid

    2016-01-01

    Full Text Available This paper presents results of sediment and cavitation erosion through Tunnel 2 and Tunnel 3 of Tarbela Dam in Pakistan. Main bend and main branch of Tunnel 2 and outlet 1 and outlet 3 of Tunnel 3 are concluded to be critical for cavitation and sediment erosion. Studies are also performed for increased sediments flow rate, concluding 5 kg/sec as the critical value for sudden increase in erosion rate density. Erosion rate is concluded to be the function of sediment flow rate and head condition. Particulate mass presently observed is reasonably low, hence presently not affecting the velocity and the flow field.

  20. LDV survey of cavitation and resonance effect on the precessing vortex rope dynamics in the draft tube of Francis turbines

    Science.gov (United States)

    Favrel, A.; Müller, A.; Landry, C.; Yamamoto, K.; Avellan, F.

    2016-11-01

    The large-scale penetration of the electrical grid by intermittent renewable energy sources requires a continuous operating range extension of hydropower plants. This causes the formation of unfavourable flow patterns in the draft tube of turbines and pump-turbines. At partial load operation, a precessing cavitation vortex rope is formed at the Francis turbine runner outlet, acting as an excitation source for the hydraulic system. In case of resonance, the resulting high-amplitude pressure pulsations can put at risk the stability of the machine and of the electrical grid to which it is connected. It is therefore crucial to understand and accurately simulate the underlying physical mechanisms in such conditions. However, the exact impact of cavitation and hydro-acoustic resonance on the flow velocity fluctuations in the draft tube remains to be established. The flow discharge pulsations expected to occur in the draft tube in resonance conditions have for instance never been verified experimentally. In this study, two-component Laser Doppler Velocimetry is used to investigate the axial and tangential velocity fluctuations at the runner outlet of a reduced scale physical model of a Francis turbine. The investigation is performed for a discharge equal to 64 % of the nominal value and three different pressure levels in the draft tube, including resonance and cavitation-free conditions. Based on the convective pressure fluctuations induced by the vortex precession, the periodical velocity fluctuations over one typical precession period are recovered by phase averaging. The impact of cavitation and hydro-acoustic resonance on both axial and tangential velocity fluctuations in terms of amplitude and phase shift is highlighted for the first time. It is shown that the occurrence of resonance does not have significant effects on the draft tube velocity fields, suggesting that the synchronous axial velocity fluctuations are surprisingly negligible compared to the velocity

  1. Influence of the fabrication process of copper matrix composites on cavitation erosion resistance

    Directory of Open Access Journals (Sweden)

    Jovana Ružić

    2018-01-01

    Full Text Available Copper matrix composites reinforced with ZrB2 particles were produced in two ways: by hot pressing (HP and laser-sintering process. Powder mixture Cu-Zr-B was mechanically alloyed before densification processes. Variations in the microstructure of treated samples obtained during cavitation test were analyzed by scanning electron microscopy (SEM. Cavitation erosion resistance was investigated with the standard test method for cavitation erosion using vibratory apparatus. Changes in mechanical alloying duration show a strong influence on cavitation erosion resistance of Cu–ZrB2 composites regardless the number of reinforcements. Laser-sintered samples show better cavitation erosion resistance than hot-pressed samples.

  2. Cavitation performance and flow characteristic in a centrifugal pump with inlet guide vanes

    Science.gov (United States)

    Tan, L.; Zha, L.; Cao, S. L.; Wang, Y. C.; Gui, S. B.

    2015-01-01

    The influence of prewhirl regulation by inlet guide vanes (IGVs) on cavitation performance and flow characteristic in a centrifugal pump is investigated. At the impeller inlet, the streamlines are regulated by the IGVs, and the axial velocity distribution is also influenced by the IGVs. Due to the total pressure loss on the IGVs, the cavitation performance of the centrifugal pump degrades. The cavitation area in impeller with IGVs is larger than one without IGVs. The specify values of total pressure loss between the suction pipe inlet and impeller inlet for three cavitation conditions show that the IGVs will generate additional pressure loss, which is related to the IGVs angles and cavitation conditions.

  3. Probability of cavitation for single ultrasound pulses applied to tissues and tissue-mimicking materials

    Science.gov (United States)

    Maxwell, Adam D.; Cain, Charles A.; Hall, Timothy L.; Fowlkes, J. Brian; Xu, Zhen

    2012-01-01

    In this article, the negative pressure values at which inertial cavitation consistently occurs in response to a single, 2-cycle, focused ultrasound pulse were measured in several media relevant to cavitation-based ultrasound therapy. The pulse was focused into a chamber containing one of the media, which included liquids, tissue-mimicking materials, and ex-vivo canine tissue. Focal waveforms were measured by two separate techniques using a fiber-optic hydrophone. Inertial cavitation was identified by high-speed photography in optically transparent media and an acoustic passive cavitation detector. The probability of cavitation (Pcav) for a single pulse as a function of peak negative pressure (p−) followed a sigmoid curve, with the probability approaching 1 when the pressure amplitude was sufficient. The statistical threshold (defined as Pcav = 0.5) was between p− = 26.0–30.0 MPa in all samples with a high water content, but varied between p− = 13.7 to > 36 MPa for other media. A model for radial cavitation bubble dynamics was employed to evaluate the behavior of cavitation nuclei at these pressure levels. A single bubble nucleus with an inertial cavitation threshold of p− = 28.2 MPa was estimated to have a 2.5 nm radius in distilled water. These data may be valuable for cavitation-based ultrasound therapy to predict the likelihood of cavitation at different pressure levels and dimensions of cavitation-induced lesions in tissue. PMID:23380152

  4. Precise spatial control of cavitation erosion in a vessel phantom by using an ultrasonic standing wave.

    Science.gov (United States)

    Shi, Aiwei; Huang, Peixuan; Guo, Shifang; Zhao, Lu; Jia, Yingjie; Zong, Yujin; Wan, Mingxi

    2016-07-01

    In atherosclerotic inducement in animal models, the conventionally used balloon injury is invasive, produces excessive vessel injuries at unpredictable locations and is inconvenient in arterioles. Fortunately, cavitation erosion, which plays an important role in therapeutic ultrasound in blood vessels, has the potential to induce atherosclerosis noninvasively at predictable sites. In this study, precise spatial control of cavitation erosion for superficial lesions in a vessel phantom was realised by using an ultrasonic standing wave (USW) with the participation of cavitation nuclei and medium-intensity ultrasound pulses. The superficial vessel erosions were restricted between adjacent pressure nodes, which were 0.87 mm apart in the USW field of 1 MHz. The erosion positions could be shifted along the vessel by nodal modulation under a submillimetre-scale accuracy without moving the ultrasound transducers. Moreover, the cavitation erosion of the proximal or distal wall could be determined by the types of cavitation nuclei and their corresponding cavitation pulses, i.e., phase-change microbubbles with cavitation pulses of 5 MHz and SonoVue microbubbles with cavitation pulses of 1 MHz. Effects of acoustic parameters of the cavitation pulses on the cavitation erosions were investigated. The flow conditions in the experiments were considered and discussed. Compared to only using travelling waves, the proposed method in this paper improves the controllability of the cavitation erosion and reduces the erosion depth, providing a more suitable approach for vessel endothelial injury while avoiding haemorrhage. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Dependence of cavitation, chemical effect, and mechanical effect thresholds on ultrasonic frequency.

    Science.gov (United States)

    Thanh Nguyen, Tam; Asakura, Yoshiyuki; Koda, Shinobu; Yasuda, Keiji

    2017-11-01

    Cavitation, chemical effect, and mechanical effect thresholds were investigated in wide frequency ranges from 22 to 4880kHz. Each threshold was measured in terms of sound pressure at fundamental frequency. Broadband noise emitted from acoustic cavitation bubbles was detected by a hydrophone to determine the cavitation threshold. Potassium iodide oxidation caused by acoustic cavitation was used to quantify the chemical effect threshold. The ultrasonic erosion of aluminum foil was conducted to estimate the mechanical effect threshold. The cavitation, chemical effect, and mechanical effect thresholds increased with increasing frequency. The chemical effect threshold was close to the cavitation threshold for all frequencies. At low frequency below 98kHz, the mechanical effect threshold was nearly equal to the cavitation threshold. However, the mechanical effect threshold was greatly higher than the cavitation threshold at high frequency. In addition, the thresholds of the second harmonic and the first ultraharmonic signals were measured to detect bubble occurrence. The threshold of the second harmonic approximated to the cavitation threshold below 1000kHz. On the other hand, the threshold of the first ultraharmonic was higher than the cavitation threshold below 98kHz and near to the cavitation threshold at high frequency. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Statistical characteristics of suction pressure signals for a centrifugal pump under cavitating conditions

    Science.gov (United States)

    Li, Xiaojun; Yu, Benxu; Ji, Yucheng; Lu, Jiaxin; Yuan, Shouqi

    2017-02-01

    Centrifugal pumps are often used in operating conditions where they can be susceptible to premature failure. The cavitation phenomenon is a common fault in centrifugal pumps and is associated with undesired effects. Among the numerous cavitation detection methods, the measurement of suction pressure fluctuation is one of the most used methods to detect or diagnose the degree of cavitation in a centrifugal pump. In this paper, a closed loop was established to investigate the pump cavitation phenomenon, the statistical parameters for PDF (Probability Density Function), Variance and RMS (Root Mean Square) were used to analyze the relationship between the cavitation performance and the suction pressure signals during the development of cavitation. It is found that the statistical parameters used in this research are able to capture critical cavitation condition and cavitation breakdown condition, whereas difficult for the detection of incipient cavitation in the pump. At part-load conditions, the pressure fluctuations at the impeller inlet show more complexity than the best efficiency point (BEP). Amplitude of PDF values of suction pressure increased steeply when the flow rate dropped to 40 m3/h (the design flow rate was 60 m3/h). One possible reason is that the flow structure in the impeller channel promotes an increase of the cavitation intensity when the flow rate is reduced to a certain degree. This shows that it is necessary to find the relationship between the cavitation instabilities and flow instabilities when centrifugal pumps operate under part-load flow rates.

  7. Assessment of cavitation in artificial approximal dental lesions with near-IR imaging

    Science.gov (United States)

    Simon, Jacob C.; Darling, Cynthia L.; Fried, Daniel

    2017-02-01

    Bitewing radiography is still considered state-of-the-art diagnostic technology for assessing cavitation within approximal carious dental lesions, even though radiographs cannot resolve cavitated surfaces but instead are used to measure lesion depth in order to predict cavitation. Clinicians need new technologies capable of determining whether approximal carious lesions have become cavitated because not all lesions progress to cavitation. Assessing lesion cavitation from near-infrared (NIR) imaging methods holds great potential due to the high transparency of enamel in the NIR region from λ=1300-1700-nm, which allows direct visualization and quantified measurements of enamel demineralization. The objective of this study was to measure the change in lesion appearance between non-cavitated and cavitated lesions in artificially generated lesions using NIR imaging modalities (two-dimensional) at λ=1300-nm and λ=1450-nm and cross-polarization optical coherence tomography (CP-OCT) (thee-dimensional) λ=1300-nm. Extracted human posterior teeth with sound proximal surfaces were chosen for this study and imaged before and after artificial lesions were made. A high speed dental hand piece was used to create artificial cavitated proximal lesions in sound samples and imaged. The cavitated artificial lesions were then filled with hydroxyapatite powder to simulate non-cavitated proximal lesions.

  8. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    Science.gov (United States)

    Shin, K. W.; Andersen, P.

    2015-12-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached eddy simulations (DES) are made for cavitating flows on three tip- modified propellers, of which one is a reference propeller having an experimental result from a cavitation tunnel test with a hull model, and the other two are modified from the reference propeller by altering the blade tip loading. DES results have been validated against the experiment in terms of sheet and cloud cavitation. In DES, non-uniform hull wake is modelled by using the inlet flow and momentum sources instead of including a hull model. A 4-bladed Kappel propeller with a smooth tip bending towards the suction side is used as the reference propeller. For the reference propeller, sheet cavitation extends over a whole chord length in the hull wake peak. As the blade gets out of the wake peak, the rear part of sheet cavity is detached in a form of cloud cavitation. For the reference propeller, the tip pitch reduction from the maximum is about 35%. When decreasing the tip pitch reduction to 10%, tip vortex cavitation is formed and cloud cavitation is significantly weakened. When increasing the tip pitch reduction to 60%, sheet cavitation slightly moves to inner radii and cloud cavitation grows larger.

  9. Effect of austempering temperature on cavitation behaviour of unalloyed ADI material

    Energy Technology Data Exchange (ETDEWEB)

    Dojcinovic, Marina [University of Belgrade, Faculty of Technology and Metallurgy, Karnegijeva 4, Belgrade (Serbia); Eric, Olivera [Innovation Centre, Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, Belgrade (Serbia); Rajnovic, Dragan; Sidjanin, Leposava [Department of Production Engineering, Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, Novi Sad (Serbia); Balos, Sebastian, E-mail: sebab@uns.ac.rs [Department of Production Engineering, Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, Novi Sad (Serbia)

    2013-08-15

    This paper provides an in-depth study and description of cavitation damage and microstructural changes in two types of unalloyed austempered ductile iron (ADI). ADI materials used were austempered at 300 and 400 °C having ausferrite microstructure with 16 and 31.4% of retained austenite, respectively. Metallographic examination was carried out to study the morphology of their cavitation-damaged surfaces. Cavitation damage was initiated at graphite nodules as well as in the interface between a graphite nodule and an ausferrite matrix. Furthermore, microcracking and ferrite/retained austenite morphology were proved to be of great importance for cavitation resistance. Mass loss rate revealed that ADI austempered at 400 °C has a higher cavitation resistance in water than ADI austempered at 300 °C. A higher amount of retained austenite in ADI austempered at 400 °C played an important role in increasing cavitation resistance. The good cavitation behaviour of ADI austempered at 400 °C was due to the matrix hardening by stress assisted phase transformation of retained austenite into martensite (SATRAM) phenomenon, as shown by X-ray diffraction analysis. - Highlights: • Cavitation rate of two ADI materials was tested. • ADI material with a lower hardness has had a lower cavitation rate. • The main reason is microstructural transformations during cavitation. • SATRAM phenomenon increases cavitation resistance.

  10. The Specialist Committee on Cavitation Induced Pressures, Final Report and Recommendations to the 23rd ITTC

    DEFF Research Database (Denmark)

    Friesch, J.; Kim, K.-H.; Andersen, Poul

    2002-01-01

    General Technical Conclusions Propeller-excited hull pressure fluctuations are strongly influenced by intermittence of sheet cavitation, the dynamics of tip vortex cavitation, and the statistical properties of the cavitation. On modern propellers, tip vortex cavitation may be even more important...... than sheet cavitation for hull pressure fluctuation. The influence of turbulence and blade surface roughness on cavitation-induced pressure fluctuations is still not quantifiable. Both experimental and numerical procedures for predicting propeller excitation need to be validated using results...... consider the influence of experimental boundary conditions: solid-boundary factors, hull vibration, and free-surface effects, before comparison with full-scale pressure levels. High-frequency excitation due to tip vortex cavitation must be considered during testing. Measurement of unsteady hull pressures...

  11. Microleakage of cavit in varnish-lined, matrix-supported endodontic access preparations.

    Science.gov (United States)

    Iqbal, M K; Saad, N A

    1998-07-01

    The effect of the application of a matrix band and the use of cavity varnish on the microleakage of Cavit in endodontic access preparations was investigated. Sixty human upper premolars were divided into six groups of ten specimens each. Access cavities with proximal extensions were prepared and filled with 1, Cavit only; 2, Cavit after application of varnish; 3, Cavit with the use of a matrix band; 4, Cavit with a matrix band and varnish; 5, incremental deposition of Cavit with the use of a matrix band and varnish; and 6, gutta percha stopping. The specimens were placed in 2% methylene blue dye, thermocycled, and evaluated for both proximal and occlusal linear leakage. The experimental group in which Cavit was incrementally deposited in varnish-lined and matrix-supported cavities exhibited significantly (p < 0.05) less proximal microleakage than those groups in which cavities were filled without the application of both a matrix band and a cavity varnish.

  12. Propeller Cavitation in Non-Uniform Flow and Correlation with the Near Pressure Field

    Directory of Open Access Journals (Sweden)

    Francisco Alves Pereira

    2016-11-01

    Full Text Available An experimental study is carried out in a cavitation tunnel on a propeller operating downstream of a non-uniform wake. The goal of this work is to establish quantitative correlations between the near pressure field and the cavitation pattern that takes place on the propeller blades. The pressure field is measured at the walls of the test section and in the near wake of the propeller and is combined with quantitative high-speed image recording of the cavitation pattern. Through harmonic analysis of the pressure data and image processing techniques that allow retrieving the cavitation extension and volume, we discuss the potential sources that generate the pressure fluctuations. Time correlations are unambiguously established between pressure peak fluctuations and cavitation collapse events, based on the Rayleigh collapse time. Finally, we design a model to predict the cavitation-induced pressure fluctuations from the derivation of the cavitation volume acceleration. A remarkable agreement is observed with the actual pressure field.

  13. Interaction between Uneven Cavity Length and Shaft Vibration at the Inception of Synchronous Rotating Cavitation

    Directory of Open Access Journals (Sweden)

    Y. Yoshida

    2008-01-01

    Full Text Available Asymmetric cavitation is known as one type of the sources of cavitation induced vibration in turbomachinery. Cavity lengths are unequal on each blade under condition of synchronous rotating cavitation, which causes synchronous shaft vibration. To investigate the relationship of the cavity length, fluid force, and shaft vibration in a cavitating inducer with three blades, we observed the unevenness of cavity length at the inception of synchronous rotating cavitation. The fluid force generated by the unevenness of the cavity length was found to grow exponentially, and the amplitude of shaft vibration was observed to increase exponentially. These experimental results indicate that the synchronous shaft vibration due to synchronous rotating cavitation is like selfexcited vibrations arising from the coupling between cavitation instability and rotordynamics.

  14. Peripapillary intrachoroidal cavitations. The Beijing eye study.

    Directory of Open Access Journals (Sweden)

    Qi Sheng You

    Full Text Available PURPOSE: To assess prevalence, size and location of peripapillary intrachoroidal cavitations (PICCs and their associations in a population-based sample. . METHODS: The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6 ± 9.8 years (range:50-93 years. A detailed ophthalmic examination included enhanced depth imaging of the choroid by spectral-domain optical coherence tomography and fundus photography. PICCs were defined as triangular thickening of the choroid with the base at the optic disc border and a distance between Bruch's membrane and sclera of ≥ 200 μm. Parapapillary large choroidal vessels were excluded. RESULTS: Out of 94 subjects with high myopia (refractive error 26.5mm in right eyes, OCT images were available for 89 (94.7% participants. A PICC was detected in 15 out of these 89 highly myopic subjects (prevalence:16.9 ± 4.0% and in none of hyperopic, emmetropic or medium myopic subgroups each consisting of 100 randomly selected subjects. Mean PICC width was 4.2 ± 2.3 hours (30° of disc circumference and mean length was 1363 ± 384 μm. PICCs were located most frequently (40% at the inferior disc border. On fundus photos, a typical yellow-orange lesion was found in 8 (53% eyes with PICCs. In binary regression analysis, presence of PICCs was significantly associated with optic disc tilting (P=0.04 and presence of posterior staphylomata (P=0.046. CONCLUSIONS: Prevalence of PICCs in the adult Chinese population was 16.9 ± 4.0% in the highly myopic group, with no PICCs detected in non-highly myopic eyes. PICCs were located most frequently at the inferior optic disc border. Only half of the PICCs detected on OCT images showed a yellow-orange lesion on fundus photos. Presence of PICC was significantly associated only with an increased optic disc tilting and presence of posterior staphylomata, while it was not associated with axial length, refractive error or other ocular or systemic parameters.

  15. Numerical modelling of unsteady 2D sheet cavitation

    NARCIS (Netherlands)

    de Lange, D.F.; de Bruin, G.J.; van Wijngaarden, L.; van Wijngaarden, L.

    1996-01-01

    Unsteady 2D sheet cavitation has been calculated by a BEM. Cubics are used to represent various quantities like the potential on the wet part of the profile, the normal velocity on the sheet, the geometry of the profile and the sheet. The growing cavity sheet, the re-entrant jet and the sheet

  16. Cavitation Modeling in Euler and Navier-Stokes Codes

    Science.gov (United States)

    Deshpande, Manish; Feng, Jinzhang; Merkle, Charles L.

    1993-01-01

    Many previous researchers have modeled sheet cavitation by means of a constant pressure solution in the cavity region coupled with a velocity potential formulation for the outer flow. The present paper discusses the issues involved in extending these cavitation models to Euler or Navier-Stokes codes. The approach taken is to start from a velocity potential model to ensure our results are compatible with those of previous researchers and available experimental data, and then to implement this model in both Euler and Navier-Stokes codes. The model is then augmented in the Navier-Stokes code by the inclusion of the energy equation which allows the effect of subcooling in the vicinity of the cavity interface to be modeled to take into account the experimentally observed reduction in cavity pressures that occurs in cryogenic fluids such as liquid hydrogen. Although our goal is to assess the practicality of implementing these cavitation models in existing three-dimensional, turbomachinery codes, the emphasis in the present paper will center on two-dimensional computations, most specifically isolated airfoils and cascades. Comparisons between velocity potential, Euler and Navier-Stokes implementations indicate they all produce consistent predictions. Comparisons with experimental results also indicate that the predictions are qualitatively correct and give a reasonable first estimate of sheet cavitation effects in both cryogenic and non-cryogenic fluids. The impact on CPU time and the code modifications required suggests that these models are appropriate for incorporation in current generation turbomachinery codes.

  17. Molecular mechanism for cavitation in water under tension

    Science.gov (United States)

    Menzl, Georg; Gonzalez, Miguel A.; Geiger, Philipp; Caupin, Frédéric; Abascal, José L. F.; Dellago, Christoph

    2016-01-01

    Despite its relevance in biology and engineering, the molecular mechanism driving cavitation in water remains unknown. Using computer simulations, we investigate the structure and dynamics of vapor bubbles emerging from metastable water at negative pressures. We find that in the early stages of cavitation, bubbles are irregularly shaped and become more spherical as they grow. Nevertheless, the free energy of bubble formation can be perfectly reproduced in the framework of classical nucleation theory (CNT) if the curvature dependence of the surface tension is taken into account. Comparison of the observed bubble dynamics to the predictions of the macroscopic Rayleigh–Plesset (RP) equation, augmented with thermal fluctuations, demonstrates that the growth of nanoscale bubbles is governed by viscous forces. Combining the dynamical prefactor determined from the RP equation with CNT based on the Kramers formalism yields an analytical expression for the cavitation rate that reproduces the simulation results very well over a wide range of pressures. Furthermore, our theoretical predictions are in excellent agreement with cavitation rates obtained from inclusion experiments. This suggests that homogeneous nucleation is observed in inclusions, whereas only heterogeneous nucleation on impurities or defects occurs in other experiments. PMID:27803329

  18. Prediction of tip vortex cavitation for ship propellers

    NARCIS (Netherlands)

    Oprea, A.I.

    2013-01-01

    An open propeller is the conventional device providing thrust for ships. Due to its working principles, regions with low pressure are formed on its blades specifically at the leading edge and in the tip region. If this pressure is becoming lower than the vapor pressure, the cavitation phenomenon is

  19. Observation of inception of sheet cavitation from free nuclei

    Science.gov (United States)

    Tsuru, Wakana; Konishi, Takafumi; Watanabe, Satoshi; Tsuda, Shin-ichi

    2017-06-01

    Prediction of inception of sheet cavitation on solid walls has been recognized to be very difficult, since it is significantly affected by the boundary layer flow characteristics, the population of free nuclei, the nuclei held in the wall roughness, the amount of dissolved air in liquid and so on. It has not sufficiently been made clear how the inception is affected by the conditions of water qualities and background flow characteristics. In this study, high speed observation of inception of sheet cavity from free nuclei is conducted for a two-dimensional convergent- divergent nozzle flow, where the sheet cavity forms just downstream of the nozzle throat. The effects of the amount of dissolved air and the free stream velocity on the inception process of sheet cavitation is examined. In addition, the bubble nuclei density, which is well known to be important factor for cavitation inception, is passively controlled by the filter installed in the tunnel. From the observations, it is confirmed that the nuclei number density significantly affects the formation of sheet cavity rather than the other two parameters. In conditions with large nuclei number density, the sheet cavity does not form, and bubbly cavitation appears instead. In the case with small nuclei number density, the sheet cavity forms from a single flowing nucleus and develops streamwisely and spanwisely. In the conditions with medium nuclei number density, the sheet cavity also forms but is shorter/ narrower streamwisely/spanwisely, due to interaction of other nuclei flowing near the formed sheet cavity.

  20. Aspects of Flow and Cavitation Around an EHL Contact

    NARCIS (Netherlands)

    van Emden, E.; Venner, Cornelis H.; Morales-Espejel, G.E.

    2016-01-01

    This paper focuses on the flow around an elasto-hydrodynamically lubricated ball-on-disc contact. Experiments in the low velocity regime with a small amount of lubricant show two flow states. When the lubricant supply at the inlet side is sufficient, a cavitation bubble is observed at the outlet

  1. Cavitation and bubble dynamics: the Kelvin impulse and its applications.

    Science.gov (United States)

    Blake, John R; Leppinen, David M; Wang, Qianxi

    2015-10-06

    Cavitation and bubble dynamics have a wide range of practical applications in a range of disciplines, including hydraulic, mechanical and naval engineering, oil exploration, clinical medicine and sonochemistry. However, this paper focuses on how a fundamental concept, the Kelvin impulse, can provide practical insights into engineering and industrial design problems. The pathway is provided through physical insight, idealized experiments and enhancing the accuracy and interpretation of the computation. In 1966, Benjamin and Ellis made a number of important statements relating to the use of the Kelvin impulse in cavitation and bubble dynamics, one of these being 'One should always reason in terms of the Kelvin impulse, not in terms of the fluid momentum…'. We revisit part of this paper, developing the Kelvin impulse from first principles, using it, not only as a check on advanced computations (for which it was first used!), but also to provide greater physical insights into cavitation bubble dynamics near boundaries (rigid, potential free surface, two-fluid interface, flexible surface and axisymmetric stagnation point flow) and to provide predictions on different types of bubble collapse behaviour, later compared against experiments. The paper concludes with two recent studies involving (i) the direction of the jet formation in a cavitation bubble close to a rigid boundary in the presence of high-intensity ultrasound propagated parallel to the surface and (ii) the study of a 'paradigm bubble model' for the collapse of a translating spherical bubble, sometimes leading to a constant velocity high-speed jet, known as the Longuet-Higgins jet.

  2. Cavitation detection of butterfly valve using support vector machines

    Science.gov (United States)

    Yang, Bo-Suk; Hwang, Won-Woo; Ko, Myung-Han; Lee, Soo-Jong

    2005-10-01

    Butterfly valves are popularly used in service in the industrial and water works pipeline systems with large diameter because of its lightweight, simple structure and the rapidity of its manipulation. Sometimes cavitation can occur, resulting in noise, vibration and rapid deterioration of the valve trim, and do not allow further operation. Thus, monitoring of cavitation is of economic interest and is very important in industry. This paper proposes a condition monitoring scheme using statistical feature evaluation and support vector machine (SVM) to detect the cavitation conditions of butterfly valve which used as a flow control valve at the pumping stations. The stationary features of vibration signals are extracted from statistical moments. The SVMs are trained, and then classify normal and cavitation conditions of control valves. The SVMs with the reorganized feature vectors can distinguish the class of the untrained and untested data. The classification validity of this method is examined by various signals acquired from butterfly valves in the pumping stations. And the classification success rate is compared with that of self-organizing feature map neural network (SOFM).

  3. Relating xylem cavitation to gas exchange in cotton

    Science.gov (United States)

    Acoustic emissions (AEs) from xylem cavitation events are characteristic of transpiration processes. Though a body of work using AE exists with a large number of species, cotton and other agronomically important crops have either not been investigated, or limited information exists. The objective of...

  4. Effect of magnetite nanoparticle agglomerates on ultrasound induced inertial cavitation.

    Science.gov (United States)

    Smith, Moira J; Ho, Vincent H B; Darton, Nicholas J; Slater, Nigel K H

    2009-06-01

    High intensity focused ultrasound (HIFU) induced inertial cavitation has been shown to improve release and cellular uptake of drugs. The effects of magnetite nanoparticle agglomerates (290+/-10nm diameter), silica coated magnetite nanoparticle agglomerates (320+/-10nm diameter) and silica particles (320+/-10nm diameter) suspended in MilliQ water on the degree of inertial cavitation due to HIFU were investigated. The HIFU transducer was operated at a frequency of 1.1 MHz, 1.67 kHz pulse repetition frequency, with applied duty cycles (DC) between 0% and 5% and different peak negative focal pressures (PNFPs) applied up to 7.2 MPa. The inertial cavitation dose (ICD: time averaged root-mean-squared broadband noise amplitude in the frequency domain) was measured in the presence and absence of nanoparticles when subjected to HIFU. Magnetite nanoparticle agglomerates caused a significant increase in the ICD above 2.7 MPa PNFP compared with MilliQ water, silica coated magnetite agglomerates and silica particles. With the dramatic increase in ICD on introduction of these magnetite agglomerates, this technique could provide a method of HIFU triggered drug delivery by enhancing inertial cavitation. The superparamagnetic properties of these particles offer the possibility of magnetic targeting to the site of disease.

  5. Transfert convectif dans les cavites poreuses soumises a un champ ...

    African Journals Online (AJOL)

    un champ magnétique transversal sur la convection naturelle bidimensionnelle en milieu poreux confiné dans une cavité horizontale. Le milieu poreux, de grande extension est chauffé isothermiquement par les côtés tandis que ses parois ...

  6. Cavitated Conglomerate Mass in Silicosis Indicating Associated Tuberculosis

    Directory of Open Access Journals (Sweden)

    Pedro Martins

    2010-01-01

    Full Text Available Silicosis is the most common occupational lung disease worldwide. It leads to respiratory impairment and may have associated infections that decrease pulmonary function. We describe the case of a 55-year-old man with chronic silicosis who presented with hemoptysis and a cavitated conglomerate mass. The final diagnosis was silicotuberculosis.

  7. NONLINEAR PERTURBATION METHOD FOR CALCULATING AXISYMMETRIC CAVITATIONAL FLOWS

    Directory of Open Access Journals (Sweden)

    Vasyl Buivol

    2013-12-01

    Full Text Available A mathematical model of a cavity under the influence of perturbations of various origins is evaluated. The model is based on hydrodynamics of flows with free boundaries and the theory of small perturbations. Specific analysis is provided for cavitational flows behind cones

  8. Cavitation cluster dynamics in shock-wave lithotripsy: Part I

    NARCIS (Netherlands)

    Arora, M.; Junge, L.; Junge, L.; Ohl, C.D.

    2005-01-01

    The spatiotemporal dynamics of cavitation bubble growth and collapse in shock-wave lithotripsy in a free field was studied experimentally. The lithotripter was equipped with two independently triggerable layers of piezoceramics. The front and back layers generated positive pressure amplitudes of 30

  9. Turbulence Modeling of Cavitating Flows in Liquid Rocket Turbopumps

    NARCIS (Netherlands)

    Mani, K.V.; Cervone, A.; Hickey, J.P.

    2017-01-01

    An accurate prediction of the performance characteristics of cavitating cryogenic turbopump inducers is essential for an increased reliance on numerical simulations in the early turbopump design stages of liquid rocket engines (LRE). This work focuses on the sensitivities related to the choice of

  10. FULLY-STEEL ALLOYS WITH INCREASED CAVITATION-EROSION PROPERTIES

    Directory of Open Access Journals (Sweden)

    M. I. Karpenko

    2004-01-01

    Full Text Available In the work the research of influence of the complex alloy addition as well as the additional microalloying by ligature NbVA, by zirconium nitride and ferrotitanium on the structure, mechanical and cavitation-erosive qualities of steels.

  11. Experimental measurements of the cavitating flow after horizontal water entry

    Science.gov (United States)

    Tat Nguyen, Thang; Hai, Duong Ngoc; Quang Thai, Nguyen; Phuong, Truong Thi

    2017-10-01

    Water-entry cavitating flow is of considerable importance in underwater high-speed applications. That is because of the drag-reduction effect that concerns the presence of a cavity around moving objects. Though the study of the flow has long been carried out, little data are documented in literature so far. Besides, currently, in the case of unsteady flow, experimental measurements of some flow parameters such as the cavity pressure still encounter difficulties. Hence continuing research efforts are of important significance. The objective of this study is to investigate experimentally the unsteady cavitating flow after the horizontal water entry of projectiles. An experimental apparatus has been developed. Qualitative and quantitative optical visualizations of the flow have been carried out by using high-speed videography. Digital image processing has been applied to analyzing the recorded flow images. Based on the known correlations between the ellipsoidal super-cavity’s size and the corresponding cavitation number, the cavity pressure has been measured by utilizing the data of image processing. A comparison between the partial- and super-cavitating flow regimes is reported. The received results can be useful for the design of high-speed underwater projectiles.

  12. Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps

    Science.gov (United States)

    Hosangadi, Ashvin; Ahuja, Vineet; Ungewitter, Ronald; Dash, Sanford M.

    2009-01-01

    A computational fluid dynamics (CFD) model that includes representations of effects of unsteady cavitation and associated dynamic loads has been developed to increase the accuracy of simulations of the performances of turbopumps. Although the model was originally intended to serve as a means of analyzing preliminary designs of turbopumps that supply cryogenic propellant liquids to rocket engines, the model could also be applied to turbopumping of other liquids: this can be considered to have been already demonstrated, in that the validation of the model was performed by comparing results of simulations performed by use of the model with results of sub-scale experiments in water. The need for this or a similar model arises as follows: Cavitation instabilities in a turbopump are generated as inlet pressure drops and vapor cavities grow on inducer blades, eventually becoming unsteady. The unsteady vapor cavities lead to rotation cavitation, in which the cavities detach from the blades and become part of a fluid mass that rotates relative to the inducer, thereby generating a fluctuating load. Other instabilities (e.g., surge instabilities) can couple with cavitation instabilities, thereby compounding the deleterious effects of unsteadiness on other components of the fluid-handling system of which the turbopump is a part and thereby, further, adversely affecting the mechanical integrity and safety of the system. Therefore, an ability to predict cavitation- instability-induced dynamic pressure loads on the blades, the shaft, and other pump parts would be valuable in helping to quantify safe margins of inducer operation and in contributing to understanding of design compromises. Prior CFD models do not afford this ability. Heretofore, the primary parameter used in quantifying cavitation performance of a turbopump inducer has been the critical suction specific speed at which head breakdown occurs. This parameter is a mean quantity calculated on the basis of assumed steady

  13. Exceptionally high cavitation erosion and corrosion resistance of a high entropy alloy.

    Science.gov (United States)

    Nair, R B; Arora, H S; Mukherjee, Sundeep; Singh, S; Singh, H; Grewal, H S

    2018-03-01

    Cavitation erosion and corrosion of structural materials are serious concerns for marine and offshore industries. Durability and performance of marine components are severely impaired due to degradation from erosion and corrosion. Utilization of advanced structural materials can play a vital role in limiting such degradation. High entropy alloys (HEAs) are a relatively new class of advanced structural materials with exceptional properties. In the present work, we report on the cavitation erosion behavior of Al 0.1 CoCrFeNi HEA in two different media: distilled water with and without 3.5wt% NaCl. For comparison, conventionally used stainless steel SS316L was also evaluated in identical test conditions. Despite lower hardness and yield strength, the HEA showed significantly longer incubation period and lower erosion-corrosion rate (nearly 1/4th) compared to SS316L steel. Enhanced erosion resistance of HEA was attributed to its high work-hardening behavior and stable passivation film on the surface. The Al 0.1 CoCrFeNi HEA showed lower corrosion current density, high pitting resistance and protection potential compared to SS316L steel. Further, HEA showed no evidence of intergranular corrosion likely due to the absence of secondary precipitates. Although, the degradation mechanisms (formation of pits and fatigue cracks) were similar for both the materials, the damage severity was found to be much higher for SS316L steel compared to HEA. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Histoplasmose pulmonar cavitária crônica Chronic cavitary pulmonary histoplasmosis

    Directory of Open Access Journals (Sweden)

    José Wellington Alves dos Santos

    2009-11-01

    Full Text Available A histoplasmose é uma micose sistêmica causada pelo fungo dimórfico térmico Histoplasma capsulatum, que pode ser isolado a partir de solo contaminado com excrementos de aves e morcegos. Dentre as apresentações clínicas dessa doença, a histoplasmose pulmonar cavitária crônica (HPCC é uma manifestação rara. O diagnóstico diferencial com tuberculose deve ser realizado em pacientes que apresentam lesões cavitadas nos segmentos pulmonares superiores. É relatado um caso de uma paciente com HPCC que apresentou dispneia progressiva e piora do padrão radiológico em quatro anos de evolução da doença.Histoplasmosis is a systemic mycosis caused by the thermally dimorphic fungus Histoplasma capsulatum, which can be isolated from soil contaminated with droppings from birds or bats. Chronic cavitary pulmonary histoplasmosis is one of the rarest clinical presentations of this disease. The differential diagnosis with tuberculosis should be made in patients presenting with cavitated lesions in upper lung segments. We report the case of a female patient with chronic cavitary pulmonary histoplasmosis who had presented with progressive dyspnea and worsening of the radiological pattern over a four-year period.

  15. Bilateral and multiple cavitation sounds during upper cervical thrust manipulation

    Directory of Open Access Journals (Sweden)

    Dunning James

    2013-01-01

    Full Text Available Abstract Background The popping produced during high-velocity, low-amplitude (HVLA thrust manipulation is a common sound; however to our knowledge, no study has previously investigated the location of cavitation sounds during manipulation of the upper cervical spine. The primary purpose was to determine which side of the spine cavitates during C1-2 rotatory HVLA thrust manipulation. Secondary aims were to calculate the average number of pops, the duration of upper cervical thrust manipulation, and the duration of a single cavitation. Methods Nineteen asymptomatic participants received two upper cervical thrust manipulations targeting the right and left C1-2 articulation, respectively. Skin mounted microphones were secured bilaterally over the transverse process of C1, and sound wave signals were recorded. Identification of the side, duration, and number of popping sounds were determined by simultaneous analysis of spectrograms with audio feedback using custom software developed in Matlab. Results Bilateral popping sounds were detected in 34 (91.9% of 37 manipulations while unilateral popping sounds were detected in just 3 (8.1% manipulations; that is, cavitation was significantly (P Conclusions Cavitation was significantly more likely to occur bilaterally than unilaterally during upper cervical HVLA thrust manipulation. Most subjects produced 3–4 pops during a single rotatory HVLA thrust manipulation targeting the right or left C1-2 articulation; therefore, practitioners of spinal manipulative therapy should expect multiple popping sounds when performing upper cervical thrust manipulation to the atlanto-axial joint. Furthermore, the traditional manual therapy approach of targeting a single ipsilateral or contralateral facet joint in the upper cervical spine may not be realistic.

  16. Simulation of leading edge cavitation on bulb turbine

    Directory of Open Access Journals (Sweden)

    Thaithacha Sudsuansee

    2011-02-01

    Full Text Available Cavitation caused by phases exchange between fluids of large density difference occurs in a region where thepressure of water falls below its vapor pressure. The density of water in a water-vapor contact area decreases dramatically.As a result, the flow in this region is compressible, which affects directly turbulent dissipation structures. Leading edgecavitation is naturally time dependent. Re-entrant jet generated by liquid flow over a cavity is a main actor of cavity shedding.Simulation of unsteady leading edge cavitation flows through a 4-blade runner bulb turbine was performed. Particular attentionwas given to the phenomena of re-entrant jet, cavity shedding, and cavitation vortices in the flow over turbine blade.The Reynolds-Average Navier-Stokes equations with finite volume discretization were used. The calculations were donewith pressure-based algorithms since the flow possesses a wide range of density change and high complexity turbulence.The new formula for dilatation dissipation parameter in k- model was introduced and the turbulent Mach number wascalculated from density of mixture instead. 2-D and 3-D hydrofoils based on both numerical and experimental results accomplisheda validation. The results show that re-entrant jet, shedding of cavity, and cavitation vortices can be captured. Inaddition, this paper also calculates the cycle frequency of torque generated by the runner and vapor area evolution on theblade surface. The cycle frequency varies with cavitation number. At normal operation of this turbine ( = 1 it is found thatboth of them have a frequency of 46 Hertz.

  17. Sugars from woody tissue photosynthesis reduce xylem vulnerability to cavitation.

    Science.gov (United States)

    De Baerdemaeker, Niels J F; Salomón, Roberto Luis; De Roo, Linus; Steppe, Kathy

    2017-11-01

    Reassimilation of internal CO 2 via woody tissue photosynthesis has a substantial effect on tree carbon income and wood production. However, little is known about its role in xylem vulnerability to cavitation and its implications in drought-driven tree mortality. Young trees of Populus nigra were subjected to light exclusion at the branch and stem levels. After 40 d, measurements of xylem water potential, diameter variation and acoustic emission (AE) were performed in detached branches to obtain acoustic vulnerability curves to cavitation following bench-top dehydration. Acoustic vulnerability curves and derived AE 50 values (i.e. water potential at which 50% of cavitation-related acoustic emissions occur) differed significantly between light-excluded and control branches (AE 50,light-excluded  = -1.00 ± 0.13 MPa; AE 50,control  = -1.45 ± 0.09 MPa; P = 0.007) denoting higher vulnerability to cavitation in light-excluded trees. Woody tissue photosynthesis represents an alternative and immediate source of nonstructural carbohydrates (NSC) that confers lower xylem vulnerability to cavitation via sugar-mediated mechanisms. Embolism repair and xylem structural changes could not explain this observation as the amount of cumulative AE and basic wood density did not differ between treatments. We suggest that woody tissue assimilates might play a role in the synthesis of xylem surfactants for nanobubble stabilization under tension. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  18. Simulation of Cavitating Flows in Diesel Injectors Simulation des écoulements en cavitation dans les injecteurs diesel

    Directory of Open Access Journals (Sweden)

    Von Dirke M.

    2006-12-01

    Full Text Available With a new two fluid model it is possible to carry out three-dimensional CFD calculations of cavitating flows in hydraulic components of Diesel injection systems. As model geometries a ball valve, a sac-hole nozzle and a one-hole nozzle have been used to test the applicability of the method. Calculations of the ensemble averaged volume fraction show the distribution of cavitation zones. Force calculations were in good agreement with the experiment. With this new tool, the design of new components can be improved. Avec un nouveau modèle à deux fluides, il est possible d'effectuer des calculs tridimensionnels de mécanique des fluides numérique pour des écoulements en cavitation dans les composants hydrauliques des systèmes d'injection Diesel. Des géométries tests comprenant un clapet à bille, un nez à sac et un nez monotrou ont été utilisées pour vérifier si la méthode est applicable. Les calculs de fraction volumique moyenne montrent la distribution des zones de cavitation Des calculs d'efforts ont mis en évidence un bon accord avec l'expérience. Ce nouvel outil permet d'améliorer la conception de nouveaux composants.

  19. Cavitation erosion of piping line behind a butterfly valve. Butterfly valve koryu ni hasseisuru cavitation ni yoru haikan no kaishoku

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, T.; Ogawa, K. (Kobe University, Kobe (Japan)); Uehara, I. (Kawasaki Heavy Industries, Ltd., Tokyo (Japan)); Kuwata, C.

    1993-11-01

    The purpose of this study is to clarify the characteristics of cavitation erosion in piping line behind a butterfly valve and to propose a method of predicting the erosion resistance. One of the major obstructions in the experiment of cavitation erosion is to take a long time by using a metal specimen. Then, a substitutive material having the fragile property to anti-cavitation erosion was used in this study. The similarity of erosion characteristics was confirmed between the substitutive material and the real material. In the second stage of this study, the substitutive material was placed as pipe wall at a bend behind a butterfly valve. It was verified from observations and measurements of the erosion position that the erosion of the material was caused by cavitation occurred at the butterfly valve. Accordingly, it was demonstrated that the erosion resistance under the real condition can be predicted from the result of the similarities of erosion characteristics of the substitutive material. 7 refs., 14 figs.

  20. Numerical simulation of cavitation flow characteristic on Pelton turbine bucket surface

    Science.gov (United States)

    Zeng, C. J.; Xiao, Y. X.; Zhu, W.; Yao, Y. Y.; Wang, Z. W.

    2015-01-01

    The internal flow in the rotating bucket of Pelton turbine is free water sheet flow with moving boundary. The runner operates under atmospheric and the cavitation in the bucket is still a controversial problem. While more and more field practice proved that there exists cavitation in the Pelton turbine bucket and the cavitation erosion may occur at the worst which will damage the bucket. So a well prediction about the cavitation flow on the bucket surface of Pelton turbine and the followed cavitation erosion characteristic can effectively guide the optimization of Pelton runner bucket and the stable operation of unit. This paper will investigate the appropriate numerical model and method for the unsteady 3D water-air-vapour multiphase cavitation flow which may occur on the Pelton bucket surface. The computational domain will include the nozzle pipe flow, semi-free surface jet and runner domain. Via comparing the numerical results of different turbulence, cavity and multiphase models, this paper will determine the suitable numerical model and method for the simulation of cavitation on the Pelton bucket surface. In order to investigate the conditions corresponding to the cavitation phenomena on the bucket surface, this paper will adopt the suitable model to simulate the various operational conditions of different water head and needle travel. Then, the characteristics of cavitation flow the development process of cavitation will be analysed in in great detail.

  1. Mechanism for cavitation in the mechanical heart valve with an artificial heart: nuclei and viscosity dependence.

    Science.gov (United States)

    Lee, Hwansung; Taenaka, Yoshiyuki; Kitamura, Soichiro

    2005-01-01

    Until now, we have estimated cavitation for mechanical heart valves (MHV) mounted in an electrohydraulic total artificial heart (EHTAH) with tap water. However, tap water at room temperature is not a proper substitute for blood at 37 degrees C. We therefore investigated fluid characterization in studies of MHV cavitation associated with the viscosity and nuclei content of a testing fluid. We used the Medtronic Hall valve mounted in the mitral position of the EHTAH. As testing fluids, tap water, distilled water, and glycerin solution were used. The valve-closing velocity, pressure-drop measurements, and a high-speed video camera were employed to determine the cavitation intensity in MHV. Most of the cavitation bubbles were observed at the edge of the valve stop. Our analysis of the results indicates that squeeze flow is the major cause of cavitation in the Medtronic Hall valve. The cavitation intensity increased with increases in the fluid viscosity and the valve-closing velocity. Even if cavitation intensity in glycerin solution was greater, the cavitation occurrence probability was less in glycerin solution than in tap water. Our results suggest that tap water contains particles that cause an increase in the cavitation occurrence probability. We conclude that cavitation intensity is greatly affected by the nuclei concentration in the fluid and the fluid viscosity.

  2. Study of surface wettability effect on cavitation inception by implementation of the lattice Boltzmann method

    Science.gov (United States)

    Ezzatneshan, Eslam

    2017-11-01

    Cavitating flow through the orifice is numerically solved by implementation of the lattice Boltzmann method. The pseudo-potential single-component multiphase Shan-Chen model is used to resolve inter-particle interactions and phase change between the liquid and its vapor. The effect of surface wettability on the cavity formation and shape is studied by imposing an appropriate wall boundary condition for the contact angle between the liquid-vapor interface and the solid surface. Efficiency of the numerical approach presented is examined by computing the cavitation inception, growth, and collapse for internal cavitating flows over a sack-wall obstacle placed inside a channel and through a convergent-divergent nozzle section. The results obtained demonstrate that hydrophobic walls act as surface nuclei and contribute to the process of cavitation inception even at high cavitation numbers. In contrast, the solid wall with hydrophilic properties shows no contribution to the onset of cavitation in the geometries studied. High values for the flow velocity corresponding to low cavitation numbers are needed to observe the cavitation inception over the geometries studied with the hydrophilic solid wall. The study shows that the present computational technique based on the implementation of the lattice Boltzmann method with the Shan-Chen model employed is robust and efficient to predict the cavitation phenomena by considering surface wettability effects and also accurate enough for computing the cavitating flow properties at different conditions.

  3. Influence of Thermodynamic Effect on Blade Load in a Cavitating Inducer

    Directory of Open Access Journals (Sweden)

    Kengo Kikuta

    2010-01-01

    Full Text Available Distribution of the blade load is one of the design parameters for a cavitating inducer. For experimental investigation of the thermodynamic effect on the blade load, we conducted experiments in both cold water and liquid nitrogen. The thermodynamic effect on cavitation notably appears in this cryogenic fluid although it can be disregarded in cold water. In these experiments, the pressure rise along the blade tip was measured. In water, the pressure increased almost linearly from the leading edge to the trailing edge at higher cavitation number. After that, with a decrease of cavitation number, pressure rise occurred only near the trailing edge. On the other hand, in liquid nitrogen, the pressure distribution was similar to that in water at a higher cavitation number, even if the cavitation number as a cavitation parameter decreased. Because the cavitation growth is suppressed by the thermodynamic effect, the distribution of the blade load does not change even at lower cavitation number. By contrast, the pressure distribution in liquid nitrogen has the same tendency as that in water if the cavity length at the blade tip is taken as a cavitation indication. From these results, it was found that the shift of the blade load to the trailing edge depended on the increase of cavity length, and that the distribution of blade load was indicated only by the cavity length independent of the thermodynamic effect.

  4. Ultrahigh-Speed Dynamics of Micrometer-Scale Inertial Cavitation from NanoparticlesUltrahigh-Speed Dynamics of Micrometer-Scale Inertial Cavitation from Nanoparticles

    NARCIS (Netherlands)

    Kwan, J.J.; Lajoinie, Guillaume Pierre Rene; de Jong, N.; Stride, E.; Versluis, Michel; Coussios, C.C.

    2016-01-01

    Direct imaging of cavitation from solid nanoparticles has been a challenge due to the combined nanosized length and time scales involved. We report on high-speed microscopic imaging of inertial cavitation from gas trapped on nanoparticles with a tunable hemispherical depression (nanocups) at

  5. Hydro-acoustic study of a butterfly valve in cavitating flow; Etude hydroacoustique d'une vanne papillon en regime cavitant

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, A.; Lauro, J.F. [Electricite de France (EDF), 75 - Paris (France). Direction des Etudes et Recherches

    1998-07-01

    The CIRCUS code (EDF/DER) allows to determine the pipework network behaviour in case of a flow submitted to hydro-acoustic excitations, generally due to some network special devices such as pumps or valves. CIRCUS uses a data base which characterizes each network component through its transfer matrix and its hydro-acoustic source. The butterfly valve in cavitating flow is a really complex component, particularly because waves propagation speed is not constant in the cavitating zone. Numerous tests have been done on the EPOCA loop in Chatou where parameters such as valve opening, flow rate and cavitation rate were examined. Waves propagation speed in the cavitating zone as well as cavitation length were characterized. Transfer Matrix was determined and the hydro-acoustic source was localized downstream of the valve and estimated. (authors)

  6. Effect of ultrasonic cavitation on measurement of sound pressure using hydrophone

    Science.gov (United States)

    Thanh Nguyen, Tam; Asakura, Yoshiyuki; Okada, Nagaya; Koda, Shinobu; Yasuda, Keiji

    2017-07-01

    Effect of ultrasonic cavitation on sound pressure at the fundamental, second harmonic, and first ultraharmonic frequencies was investigated from low to high ultrasonic intensities. The driving frequencies were 22, 304, and 488 kHz. Sound pressure was measured using a needle-type hydrophone and ultrasonic cavitation was estimated from the broadband integrated pressure (BIP). With increasing square root of electric power applied to a transducer, the sound pressure at the fundamental frequency linearly increased initially, dropped at approximately the electric power of cavitation inception, and afterward increased again. The sound pressure at the second harmonic frequency was detected just below the electric power of cavitation inception. The first ultraharmonic component appeared at around the electric power of cavitation inception at 304 and 488 kHz. However, at 22 kHz, the first ultraharmonic component appeared at a higher electric power than that of cavitation inception.

  7. Chemical effect of swirling jet-induced cavitation: degradation of rhodamine B in aqueous solution.

    Science.gov (United States)

    Wang, Xikui; Wang, Jingang; Guo, Peiquan; Guo, Weilin; Li, Guoliang

    2008-04-01

    The chemical effect of swirling jet-induced cavitation was investigated with the decomposing reaction of rhodamine B in aqueous solution. It was found that rhodamine B in aqueous solution can be degraded with swirling jet-induced cavitation and the degradation can be described by a pseudo-first-order kinetics. The effects of operating conditions such as pressure, temperature, initial concentration of rhodamine B, pH of water on the degradation rate of rhodamine B were discussed. It was found that the degradation rate of rhodamine B increased with increasing pressure and decreased with increasing initial concentration. It was also found that the degradation of rhodamine B was strongly dependent of temperature and pH of aqueous solution. The oxidation efficiency of swirling jet-induced cavitation for rhodamine B degradation was discussed and compared with ultrasonic cavitation. The result indicated that the swirling jet-induced cavitation is more energy efficient as compared to sonochemical cavitation.

  8. Enhancement of cavitation erosion resistance of 316 L stainless steel by adding molybdenum.

    Science.gov (United States)

    Li, D G; Chen, D R; Liang, P

    2017-03-01

    The influence of Mo on ultrasonic cavitation erosion of 316 L stainless steel in 3.5% NaCl solution were investigated using an ultrasonic cavitation erosion (CE) facility. The morphologies of specimen after cavitation erosion were observed by scanning electron microscopy (SEM). The results showed that the addition of Mo can sharply decrease the mean depth of erosion (MDE) of 316 L SS, implying the increased resistance of cavitation erosion. In order to better understanding the influence of Mo on the cavitation erosion of 316 L SS, the semi-conductive property of passive films on 316 L SS containing different concentrations of Mo were studied by Mott-Schottky plot. Based on Mott-Schottky results and semiconductor physics, a physical model was proposed to explain the effect mechanism of Mo on cavitation erosion of 316 L SS. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Localization of incipient tip vortex cavitation using ray based matched field inversion method

    Science.gov (United States)

    Kim, Dongho; Seong, Woojae; Choo, Youngmin; Lee, Jeunghoon

    2015-10-01

    Cavitation of marine propeller is one of the main contributing factors of broadband radiated ship noise. In this research, an algorithm for the source localization of incipient vortex cavitation is suggested. Incipient cavitation is modeled as monopole type source and matched-field inversion method is applied to find the source position by comparing the spatial correlation between measured and replicated pressure fields at the receiver array. The accuracy of source localization is improved by broadband matched-field inversion technique that enhances correlation by incoherently averaging correlations of individual frequencies. Suggested localization algorithm is verified through known virtual source and model test conducted in Samsung ship model basin cavitation tunnel. It is found that suggested localization algorithm enables efficient localization of incipient tip vortex cavitation using a few pressure data measured on the outer hull above the propeller and practically applicable to the typically performed model scale experiment in a cavitation tunnel at the early design stage.

  10. Study of unsteady cavitation flow of a pump-turbine at pump mode

    Science.gov (United States)

    Liu, J. T.; Wu, Y. L.; Liu, S. H.

    2013-12-01

    Three dimensional, unsteady, cavitating flows in a pump-turbine at pump mode were numerically studied using SST k-ω turbulence model and the mixture model. The unsteady cavitating flow and pressure fluctuations at different positions were analysed with two openings of guide vanes. Calculation results are in good agreement with experimental data. Results show that the opening of guide vanes has great effect on the cavitation phenomenon. The cavitating region gradually decreases with the increase of the relative opening, and it locates at the inlet of the suction side. The amplitude of the pressure fluctuation reduces as the cavitating region decreases. The numerical study of unsteady cavitating flow can provide a basic understanding for the improvement of stable operation of a pump-turbine.

  11. Acoustic signal characteristics of laser induced cavitation in DDFP droplet: Spectrum and time-frequency analysis.

    Science.gov (United States)

    Feng, Yi; Qin, Dui; Zhang, Jun; Ma, Chenxiang; Wan, Mingxi

    2015-01-01

    Cavitation has great application potential in microvessel damage and targeted drug delivery. Concerning cavitation, droplet vaporization has been widely investigated in vitro and in vivo with plasmonic nanoparticles. Droplets with a liquid dodecafluoropentane (DDFP) core enclosed in an albumin shell have a stable and simple structure with good characteristics of laser absorbing; thus, DDFP droplets could be an effective aim for laser-induced cavitation. The DDPF droplet was prepared and perfused in a mimic microvessel in the optical microscopic system with a passive acoustic detection module. Three patterns of laser-induced cavitation in the droplets were observed. The emitted acoustic signals showed specific spectrum components at specific time points. It was suggested that a nanosecond laser pulse could induce cavitation in DDPF droplets, and specific acoustic signals would be emitted. Analyzing its characteristics could aid in monitoring the laser-induced cavitation process in droplets, which is meaningful to theranostic application.

  12. Evaluation of Acoustic Cavitation in Terephthalic Acid Solutions Containing Gold Nanoparticles by the Spectrofluorometry Method

    OpenAIRE

    Ameneh Sazgarnia; Ahmad Shanei

    2012-01-01

    Background. When a liquid is irradiated with high intensity and low-frequency ultrasound, acoustic cavitation occurs. The existence of particles in a liquid provides nucleation sites for cavitation bubbles and leads to a decrease in the ultrasonic intensity threshold needed for cavitation onset. Materials and Methods. The study was designed to measure hydroxyl radicals in terephthalic acid solutions containing gold nanoparticles in a near field of a 1 MHz sonotherapy probe. The effect of ultr...

  13. Cavitation optimization for a centrifugal pump impeller by using orthogonal design of experiment

    Science.gov (United States)

    Pei, Ji; Yin, Tingyun; Yuan, Shouqi; Wang, Wenjie; Wang, Jiabin

    2017-01-01

    Cavitation is one of the most important performance of centrifugal pumps. However, the current optimization works of centrifugal pump are mostly focusing on hydraulic efficiency only, which may result in poor cavitation performance. Therefore, it is necessary to find an appropriate solution to improve cavitation performance with acceptable efficiency. In this paper, to improve the cavitation performance of a centrifugal pump with a vaned diffuser, the influence of impeller geometric parameters on the cavitation of the pump is investigated using the orthogonal design of experiment (DOE) based on computational fluid dynamics. The impeller inlet diameter D 1, inlet incidence angle Δ β, and blade wrap angle φ are selected as the main impeller geometric parameters and the orthogonal experiment of L9(3*3) is performed. Three-dimensional steady simulations for cavitation are conducted by using constant gas mass fraction model with second-order upwind, and the predicated cavitation performance is validated by laboratory experiment. The optimization results are obtained by the range analysis method to improve cavitation performance without obvious decreasing the efficiency of the centrifugal pump. The internal flow of the pump is analyzed in order to identify the flow behavior that can affect cavitation performance. The results show that D 1 has the greatest influence on the pump cavitation and the final optimized impeller provides better flow distribution at blade leading edge. The final optimized impeller accomplishes better cavitation and hydraulic performance and the NPSHR decreases by 0.63m compared with the original one. The presented work supplies a feasible route in engineering practice to optimize a centrifugal pump impeller for better cavitation performance.

  14. Cavitation Erosion of Electro Spark Deposited Nitinol vs. Stellite Alloy on Stainless Steel Substrate

    Science.gov (United States)

    2015-07-15

    Printed on recycled paper Approved for public release; distribution is unlimited. TECHNICAL REPORT TR-NAVFAC-EXWC-CI-1603 JULY 2015 CAVITATION ...SUBTITLE 5a. CONTRACT NUMBER CAVITATION EROSION TESTING OF ELECTRO SPARK DEPOSITED NITINOL VS STELLITE® ALLOY ON STAINLESS STEEL SUBTRATE 5b. GRANT...of combining Nitinol (NiTi) superelastic metal alloy with ElectroSpark Deposition (ESD) technology to increase the cavitation erosion resistance of

  15. The Investigation of the Cavitation Phenomenon in the Laval Nozzle with Full and Partial Surface Wetting

    Directory of Open Access Journals (Sweden)

    Jablonská Jana

    2017-04-01

    Full Text Available The article deals with the cavitation phenomenon affected by full and partial wetting of the wall. For the numerical computation of flow in the Laval nozzle the Schnerr-Sauer cavitation model was tested and was used for cavitation research of flow within the nozzle considering partial surface wetting. The coefficient of wetting for various materials was determined using experimental, theoretical and numerical methods of fluid flow due to partial surface wetting.

  16. Influence at Work Distance between the Sonotrode and Specimen to Cavitational Erosion

    Directory of Open Access Journals (Sweden)

    Relu-Costel Ciubotariu

    2015-07-01

    Full Text Available The paper presents the results of cavitation erosion tests performed on five samples from pure aluminum using the vibratory method with stationary specimen. The main purpose of this research is for determine which is the distance between the sonotrode and specimen favorable for an aggressive cavitational attack. For this, has been calculated the Mean Depth of Erosion (MDE and the cavitation erosion rate (Vec. After that the specific curve for Vec has been analytically processed.

  17. Simulation of cavitation performance of an axial flow pump with inlet guide vanes

    OpenAIRE

    Weimin Feng; Qian Cheng; Zhiwei Guo; Zhongdong Qian

    2016-01-01

    The cavitation performance of an axial flow pump with inlet guide vanes for different flow rates is studied in this article. The effects of inlet guide vanes on pump hydraulic performance and cavitation are investigated, where the total vapor fraction of impeller zone (Ftv) is calculated to predict the critical net positive suction head, which is compared with that predicted by efficiency criterion for different flow rates. The influences of the development of cavitation on internal flow in i...

  18. System and method of detecting cavitation in pumps

    Science.gov (United States)

    Lu, Bin; Sharma, Santosh Kumar; Yan, Ting; Dimino, Steven A.

    2017-10-03

    A system and method for detecting cavitation in pumps for fixed and variable supply frequency applications is disclosed. The system includes a controller having a processor programmed to repeatedly receive real-time operating current data from a motor driving a pump, generate a current frequency spectrum from the current data, and analyze current data within a pair of signature frequency bands of the current frequency spectrum. The processor is further programmed to repeatedly determine fault signatures as a function of the current data within the pair of signature frequency bands, repeatedly determine fault indices based on the fault signatures and a dynamic reference signature, compare the fault indices to a reference index, and identify a cavitation condition in a pump based on a comparison between the reference index and a current fault index.

  19. Degradation of alachlor in aqueous solution by using hydrodynamic cavitation.

    Science.gov (United States)

    Wang, Xikui; Zhang, Yong

    2009-01-15

    The degradation of alachlor aqueous solution by using hydrodynamic cavitation was systematically investigated. It was found that alachlor in aqueous solution can be deomposed with swirling jet-induced cavitation. The degradation can be described by a pseudo-first-order kinetics and the degradation rate was found to be 4.90x10(-2)min(-1). The effects of operating parameters such as fluid pressure, solution temperature, initial concentration of alachlor and medium pH on the degradation rates of alachlor were also discussed. The results showed that the degradation rates of alachlor increased with increasing pressure and decreased with increasing initial concentration. An optimum temperature of 40 degrees C existed for the degradation rate of alachlor and the degradation rate was also found to be slightly depend on medium pH. Many degradation products formed during the process, and some of them were qualitatively identified by GC-MS.

  20. Prevention of tissue damage by water jet during cavitation

    Science.gov (United States)

    Palanker, Daniel; Vankov, Alexander; Miller, Jason; Friedman, Menahem; Strauss, Moshe

    2003-08-01

    Cavitation bubbles accompany explosive vaporization of water following pulsed energy deposition in liquid media. Bubbles collapsing at the tip of a surgical endoprobe produce a powerful and damaging water jet propagating forward in the axial direction of the probe. We studied interaction of such jet with tissue using fast flash photography and modeled the flow dynamics using a two-dimensional Rayleigh-type hydrodynamic simulation. Maximal velocity of the jet generated at pulse energies of up to 1 mJ was about 80 m/s. The jet can produce tissue damage at a distance exceeding the radius of the cavitation bubble by a factor of 4. We demonstrate that formation of this flow and associated tissue damage can be prevented by application of the concave endoprobes that slow down the propagation of the back boundary of the bubble. Similar effect can be achieved by positioning an obstacle to the flow, such as a ring behind the tip.

  1. Variations of bubble cavitation and temperature elevation during acculysis

    Science.gov (United States)

    Zhou, Yufeng; Gao, Xiaobin Wilson

    2017-03-01

    High-intensity focused ultrasound (HIFU) is effective in both thermal ablations and soft-tissue fragmentation. Mechanical and thermal effects depend on the operating parameters and vary with the progress of therapy. Different types of lesions could be produced with the pulse duration of 5-30 ms, much longer than histotripsy burst but shorter than the time for tissue boiling, and pulse repetition frequency (PRF) of 0.2-5 Hz. Meanwhile, bubble cavitation and temperature elevation in the focal region were measured by passive cavitation detection (PCD) and thermocouples, respectively. Temperature in the pre-focal region is always higher than those at the focal and post-focal position in all tests. Overall, it is suggested that appropriate synergy and monitoring of mechanical and thermal effects would broaden the HIFU application and enhance its efficiency as well as safety.

  2. Study of laser-induced cavitation bubble in liquid nitrogen

    Science.gov (United States)

    Takahashi, Toshimasa; Hisano, Eizo; Toyada, Kazuhiro; Maeno, Kazuo

    2005-03-01

    The behavior of Vapor bubbles in cryogenic liquid is regarded as a cryogenic and phase-changing flow field, where instability of bubble surface becomes larger than those in normal temperature liquid as water or oil, since the cryogenic liquid has characteristic feature of small latent heat, surface tension, and viscosity. The cavitation phenomena in cryogenic temperature range are regarded as vacitation in the liquid of near-boiling point. The cryogenic cavitation, however, have a significant influence on solid surfaces due to their weakness in cryogenic range. In this paper, shock waves discharged from a pulse-laser induced bubble and behavior of the bubble are experimentally investigated. Pulsed YAG laser is used to produce a bubble in cryogenic liquid nitrogen, and shock waves are visualized by using a digital still camera with schlieren method.

  3. Modeling of Unsteady Sheet Cavitation on Marine Propeller Blades

    Directory of Open Access Journals (Sweden)

    Spyros A. Kinnas

    2003-01-01

    Full Text Available Unsteady sheet cavitation is very common on marine propulsor blades. The authors summarize a lifting-surface and a surface-panel model to solve for the unsteady cavitating flow around a propeller that is subject to nonaxisymmetric inflow. The time-dependent extent and thickness of the cavity were determined by using an iterative method. The cavity detachment was determined by applying the smooth detachment criterion in an iterative manner. A nonzeroradius developed vortex cavity model was utilized at the tip of the blade, and the trailing wake geometry was determined using a fully unsteady wake-alignment process. Comparisons of predictions by the two models and measurements from several experiments are given.

  4. Cavitation-based hydro-fracturing technique for geothermal reservoir stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John; Wang, Hong; Ren, Fei; Cox, Thomas S.

    2017-02-21

    A rotary shutter valve 500 is used for geothermal reservoir stimulation. The valve 500 includes a pressure chamber 520 for holding a working fluid (F) under pressure. A rotatable shutter 532 is turned with a powering device 544 to periodically align one or more windows 534 with one or more apertures 526 in a bulkhead 524. When aligned, the pressurized working fluid (F) flows through the bulkhead 524 and enters a pulse cavity 522, where it is discharged from the pulse cavity 522 as pressure waves 200. The pressure wave propagation 200 and eventual collapse of the bubbles 202 can be transmitted to a target rock surface 204 either in the form of a shock wave 206, or by micro jets 208, depending on the bubble-surface distance. Once cavitation at the rock face begins, fractures are initiated in the rock to create a network of micro-fissures for enhanced heat transfer.

  5. On the non-equilibrium dynamics of cavitation around the underwater projectile in variable motion

    Science.gov (United States)

    Chen, Y.; Lu, C. J.; Li, J.; Chen, X.; Gong, Z. X.

    2015-12-01

    In this work, the dynamic behavior of the non-equilibrium cavitation occurring around the underwater projectiles navigating with variable speed was numerically and theoretically investigated. The cavity collapse induced by the decelerating motion of the projectiles can be classified into two types: periodic oscillation and damped oscillation. In each type the evolution of the total mass of vapor in cavity are found to have strict correlation with the pressure oscillation in far field. By defining the equivalent radius of cavity, we introduce the specific kinetic energy of collapse and demonstrate that its change-rate is in good agreement with the pressure disturbance. We numerically investigated the influence of angle of attack on the collapse effect. The result shows that when the projectile decelerates, an asymmetric-focusing effect of the pressure induced by collapse occurs on its pressure side. We analytically explained such asymmetric-focusing effect.

  6. Sonoluminescence and sonochemiluminescence study of cavitation field in a 1.2MHz focused ultrasound

    Science.gov (United States)

    Yin, Hui; Qiao, Yangzi; Cao, Hua; Wan, Mingxi

    2017-03-01

    An intensified CCD (ICCD) and an electron-multiplying CCD (EMCCD) were employed to observe the spatial distribution of sonoluminescence (SL) and sonochemiluminescence (SCL) generated by cavitation bubbles in a 1.2MHz HIFU field. Various sonication conditions, which are free field and focal region near a water-parenchyma interface, were studied. In addition, the differences of two shells coated UCAs were also investigated. In this study, an acoustic radiation force (ARF) counterbalance appliance was added to reduce bubble displacement. Cavitation mapping in this situation was also operated through SCL recording. SCL was also employed to measure cavitation does and map the spatial distribution of cavitation near a boundary of parenchyma.

  7. Research on the induction motor current signature for centrifugal pump at cavitation condition

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2015-11-01

    Full Text Available Cavitation is a major undesirable phenomenon for centrifugal pump because it can cause hydraulic performance deterioration, pump damage by pitting and material erosion, and structural vibration and noise. Cavitation can appear within the entire range of the operating conditions; therefore, it must be prevented by all means. Sensorless monitoring technology based on motor current signature analysis is non-intrusive and economic for monitoring motor-driven equipment. Thus, this technology is suitable for centrifugal pump systems. The motor current signature for centrifugal pump load at the cavitation condition is the basis of this technology. However, systematic research is lacking on sensorless monitoring technology based on motor current signature. As a result, the tentative exploration for motor current signature at cavitation load was conducted in this study. The results show that the stator current is still a sinusoidal alternating current strictly to the law of sine. Moreover, the root mean square of the current fluctuates because of different flow regimes in the cavitation progress and decreases because vapor density is smaller than water density when cavitation is fully formed. For the stator current spectrum, the noise level, noise distribution, rotation speed, and vane pass frequency components show features in the cavitation process. These indicator indexes change according to the stage of cavitation development. Thus, the motor current signature analysis is found to be a feasible and cost-effective method for the stages of cavitation condition.

  8. A method for real-time in vitro observation of cavitation on prosthetic heart valves.

    Science.gov (United States)

    Zapanta, C M; Liszka, E G; Lamson, T C; Stinebring, D R; Deutsch, S; Geselowitz, D B; Tarbell, J M

    1994-11-01

    A method for real-time in vitro observation of cavitation on a prosthetic heart valve has been developed. Cavitation of four blood analog fluids (distilled water, aqueous glycerin, aqueous polyacrylamide, and aqueous xanthan gum) has been documented for a Medtronic/Hall prosthetic heart valve. This method employed a Penn State Electrical Ventricular Assist Device in a mock circulatory loop that was operated in a partial filling mode associated with reduced atrial filling pressure. The observations were made on a valve that was located in the mitral position, with the cavitation occurring on the inlet side after valve closure on every cycle. Stroboscopic videography was used to document the cavity life cycle. Bubble cavitation was observed on the valve occluder face. Vortex cavitation was observed at two locations in the vicinity of the valve occluder and housing. For each fluid, cavity growth and collapse occurred in less than one millisecond, which provides strong evidence that the cavitation is vaporous rather than gaseous. The cavity duration time was found to decrease with increasing atrial pressure at constant aortic pressure and beat rate. The area of cavitation was found to decrease with increasing delay time at a constant aortic pressure, atrial pressure, and beat rate. Cavitation was found to occur in each of the fluids, with the most cavitation seen in the Newtonian fluids (distilled water and aqueous glycerin).

  9. Nominal vs. Effective Wake Fields and their Influence on Propeller Cavitation Performance

    DEFF Research Database (Denmark)

    Regener, Pelle Bo; Mirsadraee, Yasaman; Andersen, Poul

    2017-01-01

    Propeller designers often need to base their design on thenominal model scale wake distribution, because the effectivefull scale distribution is not available. The effects of suchincomplete design data on cavitation performance is examinedin this paper. The behind-ship cavitation performanceof two...... flow, with a coupling ofthe two for the interaction of ship and propeller flows. Theeffect on sheet cavitation due to the different wake distributionsis examined for a typical full-form ship. Results showconsiderable differences in cavitation extent, volume, andhull pressure pulses....

  10. Study about the influence of cavitation on the dynamic characteristics for the sliding bearing

    Science.gov (United States)

    Zhai, L. M.; Luo, Y. Y.; Wang, Z. W.

    2015-01-01

    Sliding bearings are employed to support the rotor system and limit the vibration amplitude. In high speed rotor system, cavitation often occurs in the oil film and affects the dynamic characteristics of the sliding bearing greatly. In this paper, numerical method is adopted to simulate the cavitation in the oil film with homogeneous two-phase mixture flow using Singhal-et-al cavitation model in the commercial code FLUENT-solver. Cases without cavitation model were also calculated at the same time. Many computations with different frequency ratios were conducted. Then the rotor dynamic characteristics of the sliding bearing were retrieved. The results show that the cavitation has great influences on the pressure distribution in the oil film. As the rotational speed or whirling speed of the journal increases, the cavitation will become prominent. The dynamic coefficients of the bearing such as stiffness and damping with cavitation model considered are quite different from that without cavitation. So it is worth to pay attention to and do further study about the cavitation in the sliding bearing in the high speed rotor system.

  11. Investigations of effect of phase change mass transfer rate on cavitation process with homogeneous relaxation model

    Energy Technology Data Exchange (ETDEWEB)

    He, Zhixia; Zhang, Liang; Saha, Kaushik; Som, Sibendu; Duan, Lian; Wang, Qian

    2017-12-01

    The super high fuel injection pressure and micro size of nozzle orifice has been an important development trend for the fuel injection system. Accordingly, cavitation transient process, fuel compressibility, amount of noncondensable gas in the fuel and cavitation erosion have attracted more attention. Based on the fact of cavitation in itself is a kind of thermodynamic phase change process, this paper takes the perspective of the cavitation phase change mass transfer process to analyze above mentioned phenomenon. The two-phase cavitating turbulent flow simulations with VOF approach coupled with HRM cavitation model and U-RANS of standard k-ε turbulence model were performed for investigations of cavitation phase change mass transfer process. It is concluded the mass transfer time scale coefficient in the Homogenous Relaxation Model (HRM) representing mass transfer rate should tend to be as small as possible in a condition that ensured the solver stable. At very fast mass transfer rate, the phase change occurs at very thin interface between liquid and vapor phase and condensation occurs more focused and then will contribute predictably to a more serious cavitation erosion. Both the initial non-condensable gas in fuel and the fuel compressibility can accelerate the cavitation mass transfer process.

  12. Advanced Simulation Capability for Turbopump Cavitation Dynamics Guided by Experimental Validation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Numerical cavitation modeling capability is critical in the design of liquid rocket engine turbopumps, feed lines, injector manifolds and engine test facilities....

  13. Cavitation Erosion Tests Performed by Indirect Vibratory Method on Stainless Steel Welded Samples with Hardened Surface

    Directory of Open Access Journals (Sweden)

    Marian-Dumitru Nedeloni

    2012-09-01

    Full Text Available The paper presents the results of cavitation erosion tests performed on two types of samples. The materials of the samples are frequently used for manufacturing and repairs of the hydro turbines components submitted to cavitation. The first sample was made by welding of an austenitic stainless steel on austenito-feritic base material. The second sample was made similarly with the first but with a martensitic base material. After the welding processes, on both samples was applied a hardening treatment by surface peening. The cavitation erosion tests were performed on vibratory equipment using the indirect method with stationary specimen. The results show a good cavitation erosion resistance on both samples.

  14. Detecting cavitation in mercury exposed to a high-energy pulsed proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Manzi, Nicholas J [ORNL; Chitnis, Parag V [ORNL; Holt, Ray G [ORNL; Roy, Ronald A [ORNL; Cleveland, Robin O [ORNL; Riemer, Bernie [ORNL; Wendel, Mark W [ORNL

    2010-01-01

    The Oak Ridge National Laboratory Spallation Neutron Source employs a high-energy pulsed proton beam incident on a mercury target to generate short bursts of neutrons. Absorption of the proton beam produces rapid heating of the mercury, resulting in the formation of acoustic shock waves and the nucleation of cavitation bubbles. The subsequent collapse of these cavitation bubbles promote erosion of the steel target walls. Preliminary measurements using two passive cavitation detectors (megahertz-frequency focused and unfocused piezoelectric transducers) installed in a mercury test target to monitor cavitation generated by proton beams with charges ranging from 0.041 to 4.1 C will be reported on. Cavitation was initially detected for a beam charge of 0.082 C by the presence of an acoustic emission approximately 250 s after arrival of the incident proton beam. This emission was consistent with an inertial cavitation collapse of a bubble with an estimated maximum bubble radius of 0.19 mm, based on collapse time. The peak pressure in the mercury for the initiation of cavitation was predicted to be 0.6 MPa. For a beam charge of 0.41 C and higher, the lifetimes of the bubbles exceeded the reverberation time of the chamber (~300 s), and distinct windows of cavitation activity were detected, a phenomenon that likely resulted from the interaction of the reverberation in the chamber and the cavitation bubbles.

  15. Hydrodynamic cavitation as a novel approach for delignification of wheat straw for paper manufacturing.

    Science.gov (United States)

    Badve, Mandar P; Gogate, Parag R; Pandit, Aniruddha B; Csoka, Levente

    2014-01-01

    The present work deals with application of hydrodynamic cavitation for intensification of delignification of wheat straw as an essential step in the paper manufacturing process. Wheat straw was first treated with potassium hydroxide (KOH) for 48 h and subsequently alkali treated wheat straw was subjected to hydrodynamic cavitation. Hydrodynamic cavitation reactor used in the work is basically a stator and rotor assembly, where the rotor is provided with indentations and cavitational events are expected to occur on the surface of rotor as well as within the indentations. It has been observed that treatment of alkali treated wheat straw in hydrodynamic cavitation reactor for 10-15 min increases the tensile index of the synthesized paper sheets to about 50-55%, which is sufficient for paper board manufacture. The final mechanical properties of the paper can be effectively managed by controlling the processing parameters as well as the cavitational parameters. It has also been established that hydrodynamic cavitation proves to be an effective method over other standard digestion techniques of delignification in terms of electrical energy requirements as well as the required time for processing. Overall, the work is first of its kind application of hydrodynamic cavitation for enhancing the effectiveness of delignification and presents novel results of significant interest to the paper and pulp industry opening an entirely new area of application of cavitational reactors. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Numerical investigations on cavitation intensity for 3D homogeneous unsteady viscous flows

    Science.gov (United States)

    Leclercq, C.; Archer, A.; Fortes-Patella, R.

    2016-11-01

    The cavitation erosion remains an industrial issue. In this paper, we deal with the cavitation intensity which can be described as the aggressiveness - or erosive capacity - of a cavitating flow. The estimation of this intensity is a challenging problem both in terms of modelling the cavitating flow and predicting the erosion due to cavitation. For this purpose, a model was proposed to estimate cavitation intensity from 3D unsteady cavitating flow simulations. An intensity model based on pressure and void fraction derivatives was developped and applied to a NACA 65012 hydrofoil tested at LMH-EPFL (École Polytechnique Fédérale de Lausanne) [1]. 2D and 3D unsteady cavitating simulations were performed using a homogeneous model with void fraction transport equation included in Code_Saturne with cavitating module [2]. The article presents a description of the numerical code and the physical approach considered. Comparisons between 2D and 3D simulations, as well as between numerical and experimental results obtained by pitting tests, are analyzed in the paper.

  17. In vivo real-time cavitation imaging in moving organs

    Science.gov (United States)

    Arnal, B.; Baranger, J.; Demene, C.; Tanter, M.; Pernot, M.

    2017-02-01

    The stochastic nature of cavitation implies visualization of the cavitation cloud in real-time and in a discriminative manner for the safe use of focused ultrasound therapy. This visualization is sometimes possible with standard echography, but it strongly depends on the quality of the scanner, and is hindered by difficulty in discriminating from highly reflecting tissue signals in different organs. A specific approach would then permit clear validation of the cavitation position and activity. Detecting signals from a specific source with high sensitivity is a major problem in ultrasound imaging. Based on plane or diverging wave sonications, ultrafast ultrasonic imaging dramatically increases temporal resolution, and the larger amount of acquired data permits increased sensitivity in Doppler imaging. Here, we investigate a spatiotemporal singular value decomposition of ultrafast radiofrequency data to discriminate bubble clouds from tissue based on their different spatiotemporal motion and echogenicity during histotripsy. We introduce an automation to determine the parameters of this filtering. This method clearly outperforms standard temporal filtering techniques with a bubble to tissue contrast of at least 20 dB in vitro in a moving phantom and in vivo in porcine liver.

  18. Effects of bovine serum albumin on a single cavitation bubble.

    Science.gov (United States)

    Qi, Shuibao; Assouar, Badreddine; Chen, Weizhong

    2017-09-01

    The dynamics and sonoluminescence (SL) of a single cavitation bubble in bovine serum albumin (BSA) aqueous solutions have been experimentally and theoretically investigated. A phase-locked integral imaging has been used to record the bubble pulsation evolutions. The results show that, under the optimum driving condition, the endurable driving pressure, maximum radius, radius compression ratio and SL intensity of the cavitation bubble increase correspondingly with the increase of BSA concentrations within the critical micelle concentration, which indicates that the addition of BSA increases the power capability of the cavitation bubble. In addition, BSA molecules dampen the interfacial motion, and especially the rebounds of the bubble after its collapse. BSA molecules modify the dilatational viscosity and elasticity of the bubble wall. A viscoelastic interfacial rheological model that mainly emphasizes on the description of the bubble wall has been introduced and modified to theoretically explain the measured bubble dynamics. A good consensus between the experimental observation and model calculation has been achieved. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The liquid micro-jet from laser induced cavitation bubbles.

    Science.gov (United States)

    Abboud, Jack; Oweis, Ghanem

    2007-11-01

    A vaporous cavitation bubble grows spherically in an infinite medium to a maximum radius, collapses in a spherical manner to a minimum volume, and then may rebound one or more times or disintegrate. When the bubble collapses above a solid boundary, the asymmetry of the surrounding flow field will cause the upper bubble surface to cave in, resulting in a fast liquid jet that penetrates its lower surface and continues towards the solid boundary. This fast jet formation is one perceived mechanism for cavitation damage in hydro-machinery. If a hole is intentionally drilled in the solid boundary underneath the collapsing bubble, the fast micro-jet can continue its path and be cultivated for a variety of applications such as micro surgery of soft tissue. In this study, cavitation bubbles are generated by focusing the pulsed IR beam from an Nd-YAG laser above a solid surface. The forming liquid micro-jet is investigated in the cases of blank and drilled solid boundaries.

  20. Nanobubbles, cavitation, shock waves and traumatic brain injury.

    Science.gov (United States)

    Adhikari, Upendra; Goliaei, Ardeshir; Berkowitz, Max L

    2016-12-07

    Collapse of bubbles, microscopic or nanoscopic, due to their interaction with the impinging pressure wave produces a jet of particles moving in the direction of the wave. If there is a surface nearby, the high-speed jet particles hit it, and as a result damage to the surface is produced. This cavitation effect is well known and intensely studied in case of microscopic sized bubbles. It can be quite damaging to materials, including biological tissues, but it can also be beneficial when controlled, like in case of sonoporation of biological membranes for the purpose of drug delivery. Here we consider recent simulation work performed to study collapse of nanobubbles exposed to shock waves, in order to understand the detailed mechanism of the cavitation induced damage to soft materials, such as biological membranes. We also discuss the connection of the cavitation effect with the traumatic brain injury caused by blasts. Specifically, we consider possible damage to model membranes containing lipid bilayers, bilayers with embedded ion channel proteins like the ones found in neural cells and also protein assemblies found in the tight junction of the blood brain barrier.

  1. Modèle multi-bulles pour la cavitation

    Science.gov (United States)

    Adama Maiga, Mahamadou; Buisine, Daniel

    2009-11-01

    In this study we propose new multi-bubble model for cavitation, in which, to simulate the interactions within a cloud of cavitation at the initial stage, the dynamic behaviour of two nonidentical bubbles localised in a volume of control is studied. The presence of two bubbles introduces an instability in which the exchange of volume seems an additional degree of freedom. Depending on the conditions of expansion, the small bubble can disappear or not. If the small bubble disappears, the volume of control is readjusted to introduce a new small bubble and to continue calculation in a new sequence. The model makes it possible for many small bubbles to disappear as in the appearance of cavitation, which is at the origin of certain phenomena observed in the zone of the appearance, such as emission of the noise. The model reveals especially the pressure rather like a result than a datum. The comparison of the size of the bubbles and the pressure varying in time, obtained with the model are coherent with the measurements taken by Ohl [Phys. Fluids 14 (10) (2002) 3512-3521]. To cite this article: M. Adama Maiga, D. Buisine, C. R. Mecanique 337 (2009).

  2. Fast X-ray imaging of cavitating flows

    Science.gov (United States)

    Khlifa, Ilyass; Vabre, Alexandre; Hočevar, Marko; Fezzaa, Kamel; Fuzier, Sylvie; Roussette, Olivier; Coutier-Delgosha, Olivier

    2017-11-01

    A new method based on ultra-fast X-ray imaging was developed in this work for the investigation of the dynamics and the structures of complex two-phase flows. In this paper, cavitation was created inside a millimetric 2D Venturi-type test section, while seeding particles were injected into the flow. Thanks to the phase-contrast enhancement technique provided by the APS (Advanced Photon Source) synchrotron beam, high definition X-ray images of the complex cavitating flows were obtained. These images contain valuable information about both the liquid and the gaseous phases. By means of image processing, the two phases were separated, and velocity fields of each phase were, therefore, calculated using image cross-correlations. The local vapour volume fractions were also obtained, thanks to the local intensity levels within the recorded images. These simultaneous measurements, provided by this new technique, afford more insight into the structure and the dynamic of two-phase flows as well as the interactions between them, and hence enable to improve our understanding of their behaviour. In the case of cavitating flows inside a Venturi-type test section, the X-ray measurements demonstrate, for the first time, the presence of significant slip velocities between the phases within sheet cavities for both steady and unsteady flow configurations.

  3. Bubbly flow model for the dynamic characteristics of cavitating pumps

    Science.gov (United States)

    Brennen, C.

    1978-01-01

    The recent experimental transfer matrices obtained by Ng and Brennen (1978) for some axial flow pumps revealed some dynamic characteristics which were unaccounted for by any existing theoretical analysis; their visual observations suggested that the bubbly cavitating flow in the blade passages could be responsible for these effects. A theoretical model of the dynamic response of this bubbly blade-passage flow is described in the present paper. Void-fraction fluctuations in this flow result not only from pressure fluctuations but also because the fluctuating angle of attack causes fluctuations in the rate of production of bubbles near the leading edge. The latter causes kinematic waves which interact through the boundary conditions with the dynamic waves caused by pressure fluctuation. The resulting theoretical transfer functions which results are in good qualitative agreement with the experiments; with appropriate choices of two parameters good quantitative agreement is also obtained. The theoretical model also provides one possible explanation of the observation that the pump changes from an essentially passive dynamic element in the absence of cavitation to a progressively more active element as the extent of cavitation increases.

  4. Sustained Malaria Control Over an 8-Year Period in Papua New Guinea: The Challenge of Low-Density Asymptomatic Plasmodium Infections.

    Science.gov (United States)

    Koepfli, Cristian; Ome-Kaius, Maria; Jally, Shadrach; Malau, Elisheba; Maripal, Samuel; Ginny, Jason; Timinao, Lincoln; Kattenberg, Johanna Helena; Obadia, Thomas; White, Michael; Rarau, Patricia; Senn, Nicolas; Barry, Alyssa E; Kazura, James W; Mueller, Ivo; Robinson, Leanne J

    2017-12-12

    The scale-up of effective malaria control in the last decade has resulted in a substantial decline in the incidence of clinical malaria in many countries. The effects on the proportions of asymptomatic and submicroscopic infections and on transmission potential are yet poorly understood. In Papua New Guinea, vector control has been intensified since 2008, and improved diagnosis and treatment was introduced in 2012. Cross-sectional surveys were conducted in Madang Province in 2006 (with 1280 survey participants), 2010 (with 2117 participants), and 2014 (with 2516 participants). Infections were quantified by highly sensitive quantitative polymerase chain reaction (PCR) analysis, and gametocytes were quantified by reverse-transcription qPCR analysis. Plasmodium falciparum prevalence determined by qPCR decreased from 42% in 2006 to 9% in 2014. The P. vivax prevalence decreased from 42% in 2006 to 13% in 2010 but then increased to 20% in 2014. Parasite densities decreased 5-fold from 2006 to 2010; 72% of P. falciparum and 87% of P. vivax infections were submicroscopic in 2014. Gametocyte density and positivity correlated closely with parasitemia, and population gametocyte prevalence decreased 3-fold for P. falciparum and 29% for P. vivax from 2010 to 2014. Sustained control has resulted in reduced malaria transmission potential, but an increasing proportion of gametocyte carriers are asymptomatic and submicroscopic and represent a challenge to malaria control.

  5. Effect of geometrical parameters on submerged cavitation jet discharged from profiled central-body nozzle

    Science.gov (United States)

    Yang, Minguan; Xiao, Shengnan; Kang, Can; Wang, Yuli

    2013-05-01

    The flow characteristics of cavitation jets are essential issues among relevant studies. The physical properties of the jet are largely determined by the geometrical parameters of the nozzle. The structure and cavitation jets characteristics of the angular-nozzle and the self-resonating cavitation nozzle have been extensively studied, but little research is conducted in the central-body cavitation nozzle mainly because of its hard processing and the cavitation jet effect not satisfactory. In this paper, a novel central-body nozzle (a non-plunger central-body nozzle with square outlet) is studied to solve above problems. Submerged jets discharged from the novel central-body nozzle are simulated, employing the full cavitation model. The impact of nozzle configuration on jet properties is analyzed. The analysis results indicate that when central-body relative diameter keeps constant, there is an optimal contraction degree of nozzle's outlet, which can induce intense cavitation in the jet. The central-body relative diameter also affects jet profiles. In the case of large central-body relative diameter, most of the bubbles settle in the jet core. On the contrary, a smaller relative diameter makes bubbles concentrate in the interface between the jet and its surrounding fluid. Moreover, the shorter outlet part allows the cavitation zone further extend in both the axial and racial directions. The research results further consummate the study on the central-body nozzles and the correlation between cavitation jet and the structure, and elementarily reveal the mechanism of cavitation jet produced in a non-plunger novel central-body nozzle and the effect of the structure parameters on the cavitation jet, moreover, provide the theoretical basis for the optimal design of the nozzle.

  6. Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound

    Science.gov (United States)

    Radhakrishnan, Kirthi

    Cardiovascular disease is the leading cause of death and disability in the United States and worldwide. Echogenic liposomes (ELIP) are theragonistic ultrasound contrast agents (UCAs) being developed for the early detection and treatment of cardiovascular disease. Stability of the echogenicity of ELIP in physiologic conditions is crucial to their successful translation to clinical use. The stability of ELIP echogenicity was determined in vitro under physiologic conditions of total dissolved gas concentration, temperature, and hydrodynamic pressure in porcine plasma and whole blood. Ultrasound contrast agents (UCAs) have the potential to nucleate cavitation and promote both beneficial and deleterious bioeffects in vivo. Previous studies have elucidated the pressure amplitude threshold for rapid loss of echogenicity due to UCA fragmentation as a function of pulse duration and pulse repetition frequency (PRF). Previous studies have also demonstrated that UCA fragmentation was concomitant with inertial cavitation. The purpose of this study was to evaluate the relationship between stable and inertial cavitation thresholds and loss of echogenicity of ELIP as a function of pulse duration and pulse repetition frequency. Determining the relationship between cavitation thresholds and loss of echogenicity of ELIP would enable monitoring of cavitation based upon the on-screen echogenicity in clinical applications. ELIP were insonified by a clinical ultrasound scanner in duplex spectral Doppler mode at four pulse durations and four PRFs in a static fluid and in a flow system. Cavitation emissions from the UCAs insonified by Doppler pulses were recorded using a single-element passive cavitation detection (PCD) system and a passive cavitation imaging (PCI) system. Stable and inertial cavitation thresholds were ascertained. Loss of echogenicity from ELIP was assessed within regions of interest on B-mode images. Stable cavitation thresholds were found to be lower than inertial

  7. Research on Cavitation Regions of Upstream Pumping Mechanical Seal Based on Dynamic Mesh Technique

    Directory of Open Access Journals (Sweden)

    Huilong Chen

    2014-08-01

    Full Text Available In order to study the cavitation area of the Upstream Pumping Mechanical Seal, three-dimensional microgap inner flow field of the Upstream Pumping Mechanical Seal was simulated with multiphase flow cavitation model and dynamic mesh technique based on hydrodynamic lubrication theory. Furthermore, the simulated result was compared with the experimental data. The results show that the simulated result with the Zwart-Gerber-Belamri cavitation model was much closer to the experimental data. The area of cavitation inception mainly occurred at the concave side of the spiral groove and surrounding region without spiral grooves, which was nearly covered by the inner diameter to roots of grooves; in addition, the region near the surface of the stationary ring was primary cavitation location. The area of cavitation has little relationship with the medium pressure; however, it became larger following increasing rotating speed in the range of researched operating conditions. Moreover the boundary of cavitated area was transformed from smooth to rough, which occurred in similar film thickness. When cavitation number was decreasing, which was conducive to improving the lubrication performance of sealed auxiliary, it made the sealing stability decline.

  8. Modeling cavitation in a rapidly changing pressure field - application to a small ultrasonic horn.

    Science.gov (United States)

    Žnidarčič, Anton; Mettin, Robert; Dular, Matevž

    2015-01-01

    Ultrasonic horn transducers are frequently used in applications of acoustic cavitation in liquids. It has been observed that if the horn tip is sufficiently small and driven at high amplitude, cavitation is very strong, and the tip can be covered entirely by the gas/vapor phase for longer time intervals. A peculiar dynamics of the attached cavity can emerge with expansion and collapse at a self-generated frequency in the subharmonic range, i.e. below the acoustic driving frequency. The term "acoustic supercavitation" was proposed for this type of cavitation Žnidarčič et al. (2014) [1]. We tested several established hydrodynamic cavitation models on this problem, but none of them was able to correctly predict the flow features. As a specific characteristic of such acoustic cavitation problems lies in the rapidly changing driving pressures, we present an improved approach to cavitation modeling, which does not neglect the second derivatives in the Rayleigh-Plesset equation. Comparison with measurements of acoustic supercavitation at an ultrasonic horn of 20kHz frequency revealed a good agreement in terms of cavity dynamics, cavity volume and emitted pressure pulsations. The newly developed cavitation model is particularly suited for simulation of cavitating flow in highly fluctuating driving pressure fields. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Study of ultrasonic cavitation during extraction of the peanut oil at varying frequencies.

    Science.gov (United States)

    Zhang, Lei; Zhou, Cunshan; Wang, Bei; Yagoub, Abu El-Gasim A; Ma, Haile; Zhang, Xiao; Wu, Mian

    2017-07-01

    The ultrasonic extraction of oils is a typical physical processing technology. The extraction process was monitored from the standpoint of the oil quality and efficiency of oil extraction. In this study, the ultrasonic cavitation fields were measured by polyvinylidene fluoride (PVDF) sensor. Waveform of ultrasonic cavitation fields was gained and analyzed. The extraction yield and oxidation properties were compared. The relationship between the fields and cavitation oxidation was established. Numerical calculation of oscillation cycle was done for the cavitation bubbles. Results showed that the resonance frequency, f r , of the oil extraction was 40kHz. At f r , the voltage amplitude was the highest; the time was the shortest as reaching the amplitude of the waveform. Accordingly, the cavitation effect worked most rapidly, resulting in the strongest cavitation intensity. The extraction yield and oxidation properties were closely related to the cavitation effect. It controlled the cavitation oxidation effectively from the viewpoint of chemical and physical aspects. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Cavitation pitting and erosion of Al 6061-T6 in mineral oil and water

    Science.gov (United States)

    Rao, B. C. S.; Buckley, D. H.

    1983-01-01

    The authors are currently carrying out a study of the cavitation erosion of different bearing metals and alloys in mineral oils were studied. The variations of weight loss, the pit diameter and depth due to cavitation erosion on Al 6061-T6 in mineral oil and water are presented.

  11. Vibration Characteristics Induced by Cavitation in a Centrifugal Pump with Slope Volute

    Directory of Open Access Journals (Sweden)

    Ning Zhang

    2015-01-01

    Full Text Available Cavitation is one of the instability sources in centrifugal pump, which would cause some unexpected results. The goal of this paper was to analyze the influence of cavitation process on different frequency bands in a centrifugal pump with slope volute. And special attention was paid to low frequency signals, which were often filtered in the reported researches. Results show that at noncavitation condition, vibration level is closely related to flow structure interior pump. At partial flow rates, especially low flow rates, vibration level increases rapidly with the onset of rotating stall. At cavitation condition, it is proved that cavitation process has a significant impact on low frequency signals. With cavitation number decreasing, vibration level first rises to a local maximum, then it drops to a local minimum, and finally it rises again. At different flow rates, vibration trends in variable frequency bands differ obviously. Critical point inferred from vibration level is much larger than that from 3% head drop, which indicates that cavitation occurs much earlier than that reflected in head curve. Also, it is noted that high frequency signals almost increase simultaneously with cavitation occurring, which can be used to detect cavitation in centrifugal pump.

  12. Mathematical Investigation of the Cavitation Phenomenon in the Nozzle with Partially Surface Wetting

    Directory of Open Access Journals (Sweden)

    Jablonská Jana

    2015-12-01

    Full Text Available Partially surface wetting has a great influence on friction losses in the fluid flow in both the pipeline system and the complex shape of hydraulic elements. In many hydraulic elements (valves, pump impellers, cavitation is generated, which significantly changes the hydraulic flow parameters, so the last part of the article is devoted to the mathematical solution of this phenomena and evaluates the impact of wall wetting on the size and shape of the cavitation area which appears in the nozzle and in small gaps at special conditions. If the cavitation appears e. g. near the wall of pipes, the blades of turbine or a pump, then it destroys the material surface. On the basis of this physical experiment (nozzle, a two-dimensional (2D mathematical cavitation model of Schnerr-Sauer was made and calculated shape and size of the cavitation region was compared with the experiment. Later this verified model of cavitation was used for cavitation research flow with partial surface wetting. The pressure drop and the size of the cavitation area as it flows from partially surface wetting theory was tested depending on the adhesion coefficient.

  13. Effect of large elastic strains on cavitation instability predictions for elastic-plastic solids

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    1999-01-01

    For an infinite solid containing a void, the cavitation instability limit is defined as the remote stress-and strain state, at which the void grows without bound, driven by the elastic energy stored in the surrounding material. Such cavitation limits have been analysed by a number of authors...

  14. Large-eddy simulation of cavitating nozzle flow and primary jet break-up

    NARCIS (Netherlands)

    Örley, F.; Trummler, T.; Hickel, S.; Mihatsch, M.S.; Schmidt, S.J.; Adams, N.A.

    2015-01-01

    We employ a barotropic two-phase/two-fluid model to study the primary break-up of cavitating liquid jets emanating from a rectangular nozzle, which resembles a high aspect-ratio slot flow. All components (i.e., gas, liquid, and vapor) are represented by a homogeneous mixture approach. The cavitating

  15. A creep rupture model accounting for cavitation at sliding grain boundaries

    NARCIS (Netherlands)

    Giessen, Erik van der; Tvergaard, Viggo

    1991-01-01

    An axisymmetric cell model analysis is used to study creep failure by grain boundary cavitation at facets normal to the maximum principal tensile stress, taking into account the influence of cavitation and sliding at adjacent inclined grain boundaries. It is found that the interaction between the

  16. Cavitation erosion resistance of 13/4 and 21-4-N steels

    Indian Academy of Sciences (India)

    The cavitation erosion is highly dependent on microstructure and mechanical properties. The results show that hot rolled 21-4-N steel is more cavitation erosion resistant than the 13/4 and 21-4-N steels in as cast condition. The eroded surfaces were analysed through optical microscope and scanning electron microscope ...

  17. Simulation of cavitation performance of an axial flow pump with inlet guide vanes

    Directory of Open Access Journals (Sweden)

    Weimin Feng

    2016-05-01

    Full Text Available The cavitation performance of an axial flow pump with inlet guide vanes for different flow rates is studied in this article. The effects of inlet guide vanes on pump hydraulic performance and cavitation are investigated, where the total vapor fraction of impeller zone (Ftv is calculated to predict the critical net positive suction head, which is compared with that predicted by efficiency criterion for different flow rates. The influences of the development of cavitation on internal flow in impeller zone are also investigated. The results obtained show that the cavitation performance of axial flow pump can be improved at off-design flow conditions by adjusting angles of inlet guide vanes to positive values at low flow rates and by regulating angles of inlet guide vanes to negative values at high flow rates. As the net positive suction head decreases, the vapor fraction first increases slowly and then increases greatly, clearly presenting cavitation process from inception to full development, which can be used to predict the required net positive suction head. When net positive suction head decreases to the value around required net positive suction head, the cavitation zone from tip of blade suction side close to leading edge and the cavitation zone from hub part of the blade suction side connect together. After the connection, the cavitation zones have great influence on the velocity flow, leading to the decrease in pump performance.

  18. Cavitation Simulation on Conventional and Highly-Skewed Propellers in the Behind Condition

    DEFF Research Database (Denmark)

    Shin, Keun Woo; Andersen, Poul; Mikkelsen, Robert Flemming

    2011-01-01

    & Lundström 2002, Lindell 2005). The cavitation simulation is performed for the flow condition corresponding to that in the cavitation tunnel test for the ship model equipped with the propeller (Johannsen 2004, Lindell 2005). Instead of modeling the hull for the behind-hull condition, the measured wake field...

  19. Study on the Effect of Inlet Fluctuation on Cavitation in a Cone Flow Channel.

    Science.gov (United States)

    Hai, Liu; Shuping, Cao; Xiaohui, Luo

    2015-05-01

    A mathematical method was conducted to investigate the mechanism of formation of cavitation cloud, while the inlet stream contains a fluctuating flow. Based on the Rayleigh-Plesset equation and the static pressure distribution in a cone flow channel, parameters related to cavitation cloud are estimated, and the collapse pressure of the cavitation cloud is obtained by solving the equation of Mørch's model. Moreover, the effect of the amplitude and frequency of inlet fluctuation on cavitation is studied. Results revealed that the smaller the amplitude, the smaller the cloud and the lower the collapse pressure. And frequency of fluctuating stream was found to have a relative great effect on frequency of peak pressure but not so significant on peak collapse pressure and size of cloud. It is concluded that limiting the inlet fluctuation reduces the erosion and noise generated by cavitation collapse.

  20. Influence of Ultrasound Treatment on Cavitation Erosion Resistance of AlSi7 Alloy.

    Science.gov (United States)

    Pola, Annalisa; Montesano, Lorenzo; Tocci, Marialaura; La Vecchia, Giovina Marina

    2017-03-03

    Ultrasound treatment of liquid aluminum alloys is known to improve mechanical properties of castings. Aluminum foundry alloys are frequently used for production of parts that undergo severe cavitation erosion phenomena during service. In this paper, the effect of the ultrasound treatment on cavitation erosion resistance of AlSi7 alloy was assessed and compared to that of conventionally cast samples. Cavitation erosion tests were performed according to ASTM G32 standard on as-cast and heat treated castings. The response of the alloy in each condition was investigated by measuring the mass loss as a function of cavitation time and by analyzing the damaged surfaces by means of optical and scanning electron microscope. It was pointed out that the ultrasound treatment increases the cavitation erosion resistance of the alloy, as a consequence of the higher chemical and microstructural homogeneity, the finer grains and primary particles and the refined structure of the eutectic induced by the treatment itself.

  1. Experimental investigation on dynamic characteristics and strengthening mechanism of laser-induced cavitation bubbles.

    Science.gov (United States)

    Ren, X D; He, H; Tong, Y Q; Ren, Y P; Yuan, S Q; Liu, R; Zuo, C Y; Wu, K; Sui, S; Wang, D S

    2016-09-01

    The dynamic features of nanosecond laser-induced cavitation bubbles near the light alloy boundary were investigated with the high-speed photography. The shock-waves and the dynamic characteristics of the cavitation bubbles generated by the laser were detected using the hydrophone. The dynamic features and strengthening mechanism of cavitation bubbles were studied. The strengthening mechanisms of cavitation bubble were discussed when the relative distance parameter γ was within the range of 0.5-2.5. It showed that the strengthening mechanisms caused by liquid jet or shock-waves depended on γ much. The research results provided a new strengthening method based on laser-induced cavitation shotless peening (CSP). Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Influence of blade angle distribution along leading edge on cavitation performance of a centrifugal pump

    Science.gov (United States)

    Xu, Y.; Tan, L.; Cao, S. L.; Wang, Y. C.; Meng, G.; Qu, W. S.

    2015-01-01

    The influence of blade angle distribution along leading edge on cavitation performance of centrifugal pumps is analysed in the present paper. Three sets of blade angle distribution along leading edge for three blade inlet angles are chosen to design nine centrifugal pump impellers. The RNG k-epsilon turbulence model and the Zwart-Gerber-Belamri cavitation model are employed to simulate the cavitation flows in centrifugal pumps with different impellers and the same volute. The numerical results are compared with the experimental data, and the comparison proves that the numerical simulation can accurately predict the cavitation performance of centrifugal pumps. On the basis of the numerical simulations, the pump head variations with pump inlet pressure, and the flow details in centrifugal pump are revealed to demonstrate the influence of blade angle distribution along leading edge on cavitation performances of centrifugal pumps.

  3. Femtosecond laser-induced cavitations in the lens of the human eye

    DEFF Research Database (Denmark)

    Kessel, Line; Nymand, Jose; Harbst, Michael

    2007-01-01

    attempted to define the cavitation threshold in the human lens in vitro using multiphoton effects base d on radiation from a femtosecond 800 nm Ti:Sapphire laser. Cavitations were observed from pulse energy densities exceeding 16 mJ/cm2, but only after several minutes of exposure and not as a result...... of a single laser pulse. This suggests that cavitations were caused by a process which differs ITom the single-pulse cavitations observed at higher intensities. To evaluate whether the release of gas was caused by ionization and plasma formation or by thermal effects, we introduced pauses into the pulse train......, which did not change the total exposure time needed to form a cavitation. This suggests that local heating did not play a significant role in producing the observed phenomenon, suggesting that photochemical reactions may be involved. These results demonstrate that there are several types of ultrafast...

  4. Femtosecond laser-induced cavitations in the lens of the human eye

    DEFF Research Database (Denmark)

    Kessel, Line; Nymand, Jose; Harbst, Michael

    attempted to define the cavitation threshold in the human lens in vitro using multiphoton effects base d on radiation from a femtosecond 800 nm Ti:Sapphire laser. Cavitations were observed from pulse energy densities exceeding 16 mJ/cm2, but only after several minutes of exposure and not as a result...... of a single laser pulse. This suggests that cavitations were caused by a process which differs ITom the single-pulse cavitations observed at higher intensities. To evaluate whether the release of gas was caused by ionization and plasma formation or by thermal effects, we introduced pauses into the pulse train......, which did not change the total exposure time needed to form a cavitation. This suggests that local heating did not play a significant role in producing the observed phenomenon, suggesting that photochemical reactions may be involved. These results demonstrate that there are several types of ultrafast...

  5. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    DEFF Research Database (Denmark)

    Shin, K. W.; Andersen, Poul

    2015-01-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached...... eddy simulations (DES) are made for cavitating flows on three tip- modified propellers, of which one is a reference propeller having an experimental result from a cavitation tunnel test with a hull model, and the other two are modified from the reference propeller by altering the blade tip loading. DES...... results have been validated against the experiment in terms of sheet and cloud cavitation. In DES, non-uniform hull wake is modelled by using the inlet flow and momentum sources instead of including a hull model. A 4-bladed Kappel propeller with a smooth tip bending towards the suction side is used...

  6. Genotypic variability and phenotypic plasticity of cavitation resistance in Fagus sylvatica L. across Europe.

    Science.gov (United States)

    Wortemann, Rémi; Herbette, Stéphane; Barigah, Têtè Sévérien; Fumanal, Boris; Alia, Ricardo; Ducousso, Alexis; Gomory, Dusan; Roeckel-Drevet, Patricia; Cochard, Hervé

    2011-11-01

    Xylem cavitation resistance is a key physiological trait correlated with species tolerance to extreme drought stresses. Little is known about the genetic variability and phenotypic plasticity of this trait in natural tree populations. Here we measured the cavitation resistance of 17 Fagus sylvatica populations representative of the full range of the species in Europe. The trees were grown in three field trials under contrasting climatic conditions. Our findings suggest that the genotypic variability of cavitation resistance is high between genotypes of a given population. By contrast, no significant differences were found for this trait across populations, the mean population cavitation resistance being remarkably constant in each trial. We found a significant site effect and a significant site × population interaction, suggesting that cavitation resistance has a high phenotypic plasticity and that this plasticity is under genetic control. The implications of our findings for beech forest management in a context of climate change are discussed.

  7. A CFD and experimental study on cavitation in positive displacement pumps: Benefits and drawbacks of the ‘full’ cavitation model

    Directory of Open Access Journals (Sweden)

    Aldo Iannetti

    2016-01-01

    Full Text Available To fill the gap in the literature in terms of numerical studies of positive displacement (PD pumps in a cavitating condition, a comprehensive and transient computational fluid dynamics (CFD model of a PD pump, simulating the cavitation arising during the suction stroke, was created. The ‘full’ cavitation model was utilized to study its capability on PD pump cavitation. A set of three plunger speeds were simulated. Using the highest plunger speed, an assessment was made of the effect of 1.5, 3, 4.5 and 15 parts per million (ppm of air mass fraction on pump performance and cavitation. An experimental test rig, replicating the CFD model, was designed and built in order to validate the numerical model and find its weaknesses. CFD modeled, in a consistent way, the fluid dynamics phenomena related to cavitation (the chamber pressure approaching the vapor pressure, the vaporization/condensation and the pressure spike occurrence at the end of the suction stroke marking the end of cavitation. On the other hand the CFD pressure trends calculated appeared stretched along the time axis with respect to the experimental data, and this highlighted issues in the multiphase and cavitation models: the vaporization/condensation rate calculated by CFD did not follow the real dynamics correctly because the non-condensable gas expansion was overestimated. This was seen when comparing the CFD/experimental results where the simulated pressure drop gradient at the beginning of the suction stroke and the pressure peaks as the valve closed exhibited a delay in their occurrence. The simulation results were sensitive to the dissolved air mass fraction as the delay depended on the amount of air dissolved in the water. Although the influence of the air mass fraction was considered consistent, the 3 ppm CFD case was the closest to the experimental results, whereas the analyst expected the 15 ppm case to be more accurate.

  8. Activating Molecules, Ions, and Solid Particles with Acoustic Cavitation

    Science.gov (United States)

    Pflieger, Rachel; Chave, Tony; Virot, Matthieu; Nikitenko, Sergey I.

    2014-01-01

    The chemical and physical effects of ultrasound arise not from a direct interaction of molecules with sound waves, but rather from the acoustic cavitation: the nucleation, growth, and implosive collapse of microbubbles in liquids submitted to power ultrasound. The violent implosion of bubbles leads to the formation of chemically reactive species and to the emission of light, named sonoluminescence. In this manuscript, we describe the techniques allowing study of extreme intrabubble conditions and chemical reactivity of acoustic cavitation in solutions. The analysis of sonoluminescence spectra of water sparged with noble gases provides evidence for nonequilibrium plasma formation. The photons and the "hot" particles generated by cavitation bubbles enable to excite the non-volatile species in solutions increasing their chemical reactivity. For example the mechanism of ultrabright sonoluminescence of uranyl ions in acidic solutions varies with uranium concentration: sonophotoluminescence dominates in diluted solutions, and collisional excitation contributes at higher uranium concentration. Secondary sonochemical products may arise from chemically active species that are formed inside the bubble, but then diffuse into the liquid phase and react with solution precursors to form a variety of products. For instance, the sonochemical reduction of Pt(IV) in pure water provides an innovative synthetic route for monodispersed nanoparticles of metallic platinum without any templates or capping agents. Many studies reveal the advantages of ultrasound to activate the divided solids. In general, the mechanical effects of ultrasound strongly contribute in heterogeneous systems in addition to chemical effects. In particular, the sonolysis of PuO2 powder in pure water yields stable colloids of plutonium due to both effects. PMID:24747272

  9. Loss of echogenicity and onset of cavitation from echogenic liposomes: pulse repetition frequency independence.

    Science.gov (United States)

    Radhakrishnan, Kirthi; Haworth, Kevin J; Peng, Tao; McPherson, David D; Holland, Christy K

    2015-01-01

    Echogenic liposomes (ELIP) are being developed for the early detection and treatment of atherosclerotic lesions. An 80% loss of echogenicity of ELIP has been found to be concomitant with the onset of stable and inertial cavitation. The ultrasound pressure amplitude at which this occurs is weakly dependent on pulse duration. It has been reported that the rapid fragmentation threshold of ELIP (based on changes in echogenicity) is dependent on the insonation pulse repetition frequency (PRF). The study described here evaluates the relationship between loss of echogenicity and cavitation emissions from ELIP insonified by duplex Doppler pulses at four PRFs (1.25, 2.5, 5 and 8.33 kHz). Loss of echogenicity was evaluated on B-mode images of ELIP. Cavitation emissions from ELIP were recorded passively on a focused single-element transducer and a linear array. Emissions recorded by the linear array were beamformed, and the spatial widths of stable and inertial cavitation emissions were compared with the calibrated azimuthal beamwidth of the Doppler pulse exceeding the stable and inertial cavitation thresholds. The inertial cavitation thresholds had a very weak dependence on PRF, and stable cavitation thresholds were independent of PRF. The spatial widths of the cavitation emissions recorded by the passive cavitation imaging system agreed with the calibrated Doppler beamwidths. The results also indicate that 64%-79% loss of echogenicity can be used to classify the presence or absence of cavitation emissions with greater than 80% accuracy. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. The role of positive and negative pressure on cavitation nucleation in nanodroplet-mediated histotripsy.

    Science.gov (United States)

    Vlaisavljevich, Eli; Aydin, Omer; Lin, Kuang-Wei; Durmaz, Yasemin Yuksel; Fowlkes, Brian; ElSayed, Mohamed; Xu, Zhen

    2016-01-21

    Nanodroplet-mediated histotripsy (NMH) is an ultrasound ablation technique combining histotripsy with acoustically sensitive perfluorocarbon (PFC) nanodroplets that can be selectively delivered to tumor cells for targeted tumor ablation. NMH takes advantage of the significantly reduced cavitation threshold of the nanodroplets, allowing for cavitation to be selectively generated only in regions containing nanodroplets. Understanding the physical mechanisms underlying the nanodroplet cavitation process is essential to the development of NMH. In this study, we hypothesize that cavitation nucleation is caused by the negative pressure (p-) exposed to the PFC, and the NMH cavitation threshold is therefore determined by the incident p-  of the single-cycle pulses commonly used in NMH. This paper reports the first study that separately investigates the effects of negative and positive pressure on the NMH cavitation threshold using near half-cycle ultrasound pulses with dominant negative (negative-polarity pulses) or positive (positive-polarity pulses) pressure phases. Tissue phantoms containing perfluorohexane (PFH) nanodroplets were exposed to negative-polarity and positive-polarity pulses generated by a frequency compounding transducer recently developed in our lab, and the probability of generating cavitation was measured as a function of peak negative (p-) and peak positive (p+) pressure. The results showed close agreement in the p- cavitation threshold for PFH phantoms exposed to negative-polarity (11.4 ± 0.1 MPa) and positive-polarity (11.7 ± 0.2 MPa) pulses. The p+ at the cavitation threshold, in contrast, was measured to be sign ficantly different for the negative-polarity (4.0 ± 0.1 MPa) and positive-polarity (42.6 ± 0.2 MPa) pulses. In the final part of this study, the experimental results were compared to the cavitation threshold predicted by classical nucleation theory (CNT), with results showing close agreement between simulations and experiments

  11. Decolourization of Rhodamine B: A swirling jet-induced cavitation combined with NaOCl.

    Science.gov (United States)

    Mancuso, Giuseppe; Langone, Michela; Laezza, Marco; Andreottola, Gianni

    2016-09-01

    A hydrodynamic cavitation reactor (Ecowirl) based on swirling jet-induced cavitation has been used in order to allow the degradation of a waste dye aqueous solution (Rhodamine B, RhB). Cavitation generated by Ecowirl reactor was directly compared with cavitation generated by using multiple hole orifice plates. The effects of operating conditions and parameters such as pressure, pH of dye solution, initial concentration of RhB and geometry of the cavitating devices on the degradation rate of RhB were discussed. In similar operative conditions, higher extents of degradation (ED) were obtained using Ecowirl reactor rather than orifice plate. An increase in the ED from 8.6% to 14.7% was observed moving from hole orifice plates to Ecowirl reactor. Intensification in ED of RhB by using hydrodynamic cavitation in presence of NaOCl as additive has been studied. It was found that the decolourization was most efficient for the combination of hydrodynamic cavitation and chemical oxidation as compared to chemical oxidation and hydrodynamic cavitation alone. The value of ED of 83.4% was reached in 37min using Ecowirl combined with NaOCl (4.0mgL(-1)) as compared to the 100min needed by only mixing NaOCl at the same concentration. At last, the energetic consumptions of the cavitation devices have been evaluated. Increasing the ED and reducing the treatment time, Ecowirl reactor resulted to be more energy efficient as compared to hole orifice plates, Venturi and other swirling jet-induced cavitation devices, as reported in literature. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Modeling Cavitation in ICE Pistons Made with Isothermal Forging

    Directory of Open Access Journals (Sweden)

    V.V. Astanin

    2014-07-01

    Full Text Available Possible causes for cavitations in parts made with an Al-Si eutectic alloy AK12D (AlSi12 were explored with mathematical and physical modeling with involved acoustic emission. Pores were formed from micro-cracks, which appear during the early stages of a deformation process, with the help of micro-stresses appearing at phase boundaries (Al/Si interface due to thermal expansion. At the design stage of isothermal forgings of such products it is recommended to provide a scheme of the deformed shape, which is under uniform compression, to compensate for the inter-phase stresses.

  13. Shock wave emission during the collapse of cavitation bubbles

    Science.gov (United States)

    Garen, W.; Hegedűs, F.; Kai, Y.; Koch, S.; Meyerer, B.; Neu, W.; Teubner, U.

    2016-07-01

    Shock wave emission induced by intense laser pulses is investigated experimentally. The present work focuses on the conditions of shock wave emission in glycerine and distilled water during the first bubble collapse. Experimental investigations are carried out in liquids as a function of temperature and viscosity. Comparison is made with the theoretical work of Poritsky (Proc 1st US Natl Congress Appl Mech 813-821, 1952) and Brennen (Cavitation and bubble dynamics, Oxford University Press 1995). To the best knowledge of the authors, this is the first experimental verification of those theories.

  14. Cavitation and acoustic emission around laser-heated microparticles

    Science.gov (United States)

    Lin, Charles P.; Kelly, Michael W.

    1998-06-01

    We studied transient cavitation bubble formation and acoustic emission around individual laser-heated microparticles using subnanosecond time-resolved microscopy. Microcavitation bubbles were observed as early as 0.5 ns after the particles were heated by a 30 ps laser pulse. The bubbles expanded to a few micrometers in size and collapsed on the time scale of 0.1-1 μsec. We discuss microcavitation as the origin of anomalously large photoacoustic effects and nonlinear optical responses observed in laser-heated colloidal suspensions, as well as a mechanism for cellular damage in biologic tissue containing pigment particles.

  15. Cavitation inception by almost spherical solid particles in water

    DEFF Research Database (Denmark)

    Marschall, H.B.; Mørch, Knud Aage; Keller, A.P.

    2003-01-01

    The tensile strength of water increases when solid particles are filtered out, and it becomes greater the smaller the remaining particles are. Natural particles are of random shape, making parametric studies on the relationship between tensile strength and particle characteristics difficult. In t...... that cavitation nuclei are related to the fine scale surface structures observed on the balls, and in dependence of their global radii of curvature, critical cavities are developed. A model of this development is presented. ©2003 American Institute of Physics....

  16. Aspergillus infection in pulmonary cavitating lesions with right atrial myxoma.

    Science.gov (United States)

    Sharma, Divyesh; Dorgan, Eileen; Douglas, Hannah; Trouton, Tom; McMullan, Ronan; Parissis, Haralabos

    2014-11-01

    Cardiac myxomas are rare primary tumors with varied clinical presentations that may pose a diagnostic challenge. Here, we describe the case of a 21-year-old man with multiple cavitating lung lesions with aspergillosis and underlying right atrial myxoma, who presented with hemoptysis and weight loss. He was successfully treated with right atrial myxoma resection and antifungal agents, with no recurrence or complications after one year of follow-up. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. Sonochemical nanosynthesis at the engineered interface of a cavitation microbubble.

    Science.gov (United States)

    Shchukin, Dmitry G; Möhwald, Helmuth

    2006-08-14

    This work demonstrates the potential of sonochemistry to become a most valuable tool for nanotechnology if the underlying complex processes are understood and controlled. It is shown that control of cavitation requires controlling of interfaces at the microsec time scale and thus a diversity of phenomena are observed using different surfactants. By means of concrete examples it is shown that non-equilibrium nanostructures, e.g. Ru/Pt core-shell nanoparticles can be prepared. Hollow microbubbles with nanoparticles in the wall, which may contain gases over weeks, can be constructed by sonication of the corresponding colloid solutions.

  18. A novel brewing process via controlled hydrodynamic cavitation

    CERN Document Server

    Albanese, Lorenzo; Meneguzzo, Francesco; Pagliaro, Mario

    2016-01-01

    This paper describes a completely new brewing equipment and process based upon controlled hydrodynamic cavitation, providing significant advantages in terms of lowered capital cost, reduced production time, enhanced energy and production efficiency, food safety, while preserving beer organoleptic qualities. Experiments carried out on real microbrewery volume scale using the new and conventional technology unquestionably confirm the relevance of the new findings. Impacts of these discoveries are potentially far reaching, as beer is the worldwide most widely consumed alcoholic beverage, therefore highly relevant to health, environment the economy and even to local identities.

  19. Enhancement of sonoluminescence emission from a multibubble cavitation zone.

    Science.gov (United States)

    Dezhkunov, N V; Francescutto, A; Ciuti, P; Mason, T J; Iernetti, G; Kulak, A I

    2000-01-01

    Investigations have been performed on various methods of increasing cavitation activity measured by the intensity of sonoluminescence. It is shown that the effect of the combined action of (a) pulsed modulation of an acoustic field, (b) liquid degassing and cooling and (c) increasing the static pressure considerably exceeds the sum of the effects achieved by each of these methods individually. A more than 250-fold increase of the sonoluminescence intensity has been attained compared with continuous irradiation under normal conditions (room temperature, atmospheric pressure, gas-saturated liquid). An interpretation of the results obtained is proposed.

  20. Structure of Micro-nano WC-10Co4Cr Coating and Cavitation Erosion Resistance in NaCl Solution

    Science.gov (United States)

    Ding, Xiang; Cheng, Xu-Dong; Yuan, Cheng-Qing; Shi, Jin; Ding, Zhang-Xiong

    2017-09-01

    Cavitation erosion (CE) is the predominant cause for the failure of overflow components in fluid machinery. Advanced coatings have provided an effective solution to cavitation erosion due to the rapid development of surface engineering techniques. However, the influence of coating structures on CE resistance has not been systematically studied. To better understand their relationship, micro-nano and conventional WC-10Co4Cr cermet coatings are deposited by high velocity oxygen fuel spraying(HVOF), and their microstructures are analyzed by OM, SEM and XRD. Meanwhile, characterizations of mechanical and electrochemical properties of the coatings are carried out, as well as the coatings' resistance to CE in 3.5 wt % NaCl solution, and the cavitation mechanisms are explored. Results show that micro-nano WC-10Co4Cr coating possesses dense microstructure, excellent mechanical and electrochemical properties, with very low porosity of 0.26 ± 0.07% and extraordinary fracture toughness of 5.58 ± 0.51 MPa·m1/2. Moreover, the CE resistance of micro-nano coating is enhanced above 50% than conventional coating at the steady CE period in 3.5 wt % NaCl solution. The superior CE resistance of micro-nano WC-10Co4Cr coating may originate from the unique micro-nano structure and properties, which can effectively obstruct the formation and propagation of CE crack. Thus, a new method is proposed to enhance the CE resistance of WC-10Co4Cr coating by manipulating the microstructure.

  1. High HIV incidence in the postpartum period sustains vertical transmission in settings with generalized epidemics: a cohort study in Southern Mozambique

    Directory of Open Access Journals (Sweden)

    Caroline De Schacht

    2014-03-01

    Full Text Available Introduction: Acute infection with HIV in the postpartum period results in a high risk of vertical transmission through breastfeeding. A study was done to determine the HIV incidence rate and associated risk factors among postpartum women in Southern Mozambique, where HIV prevalence among pregnant women is 21%. Methods: A prospective cohort study was conducted in six rural health facilities in Gaza and Maputo provinces from March 2008 to July 2011. A total of 1221 women who were HIV-negative on testing at delivery or within two months postpartum were recruited and followed until 18 months postpartum. HIV testing, collection of dried blood spot samples and administration of a structured questionnaire to women were performed every three months. Infant testing by DNA-PCR was done as soon as possible after identification of a new infection in women. HIV incidence was estimated, and potential risk factors at baseline were compared using Poisson regression. Results: Data from 957 women were analyzed with follow-up after the enrolment visit, with a median follow-up of 18.2 months. The HIV incidence in postpartum women is estimated at 3.20/100 women-years (95% CI: 2.30–4.46, with the highest rate among 18- to 19-year-olds (4.92 per 100 women-years; 95% CI: 2.65–9.15. Of the new infections, 14 (34% were identified during the first six months postpartum, 11 (27% between 6 and 12 months and 16 (39% between 12 and 18 months postpartum. Risk factors for incident HIV infection include young age, low number of children, higher education level of the woman's partner and having had sex with someone other than one's partner. The vertical transmission was 21% (95% CI: 5–36 among newly infected women. Conclusions: Incidence of HIV is high among breastfeeding women in Southern Mozambique, contributing to increasing numbers of HIV-infected infants. Comprehensive primary prevention strategies targeting women of reproductive age, particularly pregnant and

  2. Sustentabilidade na era das conferências sobre meio ambiente e desenvolvimento - um olhar para ecologia e economia Sustainability in the period of conferences on the environment and development - an insight into ecology and economics

    Directory of Open Access Journals (Sweden)

    Roberto Donato Silva Junior

    2013-03-01

    , sin embargo, también dificulta la inserción de elemento socioculturales al debate.This work presents an analysis of the scientific production about sustainability in ecology and economy areas in the period between Rio92 and Rio+20. The focus is in the stress between disciplinarity and interdisciplinarity in the context of the establishment of the relation between scientific artifact and politic propositiveness. Thus, this study analyzed fifteen articles among the twenty five most quoted articles in the website "web of Science" both in ecology and economy, regarding "sustainability" and "sustainable" topics between 1990 and 2009. The analysis was founded in the theory of reflective modernization and in social studies of science. Finally, this study suggests the existence of a "disciplinary interdisciplinarity" between economy and ecology that facilitates its connections and operations; however it also hinders the insertion of socio-cultural elements to the debate.

  3. Destruction Mechanism of ZnAl4 as Cast Alloy Subjected to Cavitational Erosion Using Different Laboratory Stands

    Directory of Open Access Journals (Sweden)

    Jasionowski R.

    2016-03-01

    Full Text Available The main reason of a cavitational destruction is the mechanical action of cavitation pulses onto the material’s surface. The course of cavitation destruction process is very complex and depends on the physicochemical and structural features of a material. A resistance to cavitation destruction of the material increases with the increase of its mechanical strength, fatigue resistance as well as hardness. Nevertheless, the effect of structural features on the material’s cavitational resistance has been not fully clarified. In the present paper, the cavitation destruction of ZnAl4 as cast alloy was investigated on three laboratory stands: vibration, jet-impact and flow stands. The destruction mechanism of ZnAl4 as cast alloy subjected to cavitational erosion using various laboratory stands is shown in the present paper.

  4. Numerical Analysis of Tip Cavitation on Marine Propeller with Wake Alignment Using a Simple Surface Panel Method “SQCM”

    Science.gov (United States)

    Kanemaru, T.; Ando, J.

    2015-12-01

    This paper presents the calculation method of tip cavitation with wake alignment. Tip cavitation consists of tip vortex cavitation and tip super cavitation which means the undeveloped and local super cavitation around blade tip. The feature of this study is that the method applies the wake alignment model in order to express the realistic phenomena of tip cavitation and predict the pressure fluctuation more accurately. In the present method, the wake sheet is deformed according to the induced velocity vector on the vortex lines. The singularity of the potential vortex can be removed by using the Rankine Vortex model. This paper shows the calculated results regarding cavitation pattern, pressure fluctuation etc. comparing with published experimental data and calculated results without wake alignment.

  5. Risk factors for pulmonary cavitation in tuberculosis patients from China.

    Science.gov (United States)

    Zhang, Liqun; Pang, Yu; Yu, Xia; Wang, Yufeng; Lu, Jie; Gao, Mengqiu; Huang, Hairong; Zhao, Yanlin

    2016-10-12

    Pulmonary cavitation is one of the most frequently observed clinical characteristics in tuberculosis (TB). The objective of this study was to investigate the potential risk factors associated with cavitary TB in China. A total of 385 smear-positive patients were enrolled in the study, including 192 (49.9%) patients with cavitation as determined by radiographic findings. Statistical analysis revealed that the distribution of patients with diabetes in the cavitary group was significantly higher than that in the non-cavitary group (adjusted odds ratio (OR) (95% confidence interval (CI)):12.08 (5.75-25.35), Ptuberculosis strains, 330 strains (85.7%) were classified as the Beijing genotype, which included 260 strains that belonged to the modern Beijing sublineage and 70 to the ancient Beijing sublineage. In addition, there were 80 and 31 strains belonging to large and small clusters, respectively. Statistical analysis revealed that cavitary disease was observed more frequently among the large clusters than the small clusters (P=0.037). In conclusion, our findings demonstrate that diabetes and multidrug resistance are risk factors associated with cavitary TB. In addition, there was no significant difference in the cavitary presentation between patients infected with the Beijing genotype strains and those infected with the non-Beijing genotype strains.

  6. The effect of relaxation on cavitation dynamics in viscoelastic media

    Science.gov (United States)

    Mancia, Lauren; Warnez, Matthew; Johnsen, Eric

    2014-11-01

    Cavitation plays an important role in diagnostic and therapeutic ultrasound. In certain applications, cavitation bubbles are produced directly in soft tissue, a viscoelastic medium. Although bubble dynamics research in water has received significant attention, the behavior of bubbles in tissue-like media is much less well understood, as the dynamics are strongly affected by the viscoelastic properties of the surroundings, including viscosity, elasticity and relaxation. In the present work, we numerically investigate the role of stress relaxation on spherical bubble dynamics. We simulate bubble dynamics in viscoelastic media with linear and nonlinear relaxation under different types of forcing. Results indicate that the presence of relaxation causes faster growth rates and permits bubble rebound driven purely by residual stresses in the surroundings, a phenomenon not observed in Newtonian media. Differences between nonlinear models become important only following a strong collapse (in which high stresses are generated), thus requiring a robust numerical approach. This work was supported by NSF Grant Number CBET 1253157 and NIH Grant Number 1R01HL110990-01A1.

  7. Drop fragmentation by laser-induced cavitation bubbles

    Science.gov (United States)

    Gonzalez-A, S. Roberto; Kerssens, Pjotr; Ohl, Claus-Dieter

    2015-11-01

    The fragmentation of water droplets by a short laser pulse has received significant attention since the 70's. The fundamental understanding of droplet vaporization/fragmentation is of interest in laser beam propagation in the atmosphere, in situ analysis of combustion products -a great concern due to its ecological implications- and more recently driven by a better understanding of the drop shaping by a laser pulse which is of interest in the development of extreme ultraviolet (EUV) machines. In this presentation we discuss about the incipient events that lead to the fragmentation of a drop produced by a cavitation bubble. When the bubble expands, it stretches the drop into a thin liquid film; this liquid film is eventually ruptured and a shockwave and small droplets are ejected as fast as 4 times the speed of sound in air. Interestingly, we also observe bubbles on the surface of the stretched film. Numerical simulations of a shock wave propagating inside a droplet show that cavitation bubbles appear when counter propagating shock waves that rebound from the walls of the drop meet. We also show different fragmentation scenarios recorded with high-speed video, one of them being a jelly fish like liquid film that eventually fragments into smaller drops.

  8. Cavitation/boundary effects in a simple head impact model.

    Science.gov (United States)

    Nusholtz, G S; Wylie, B; Glascoe, L G

    1995-07-01

    An experimental and numerical analysis of the impact response of a simple model of the human head is presented. A water-filled 14-cm diameter cylinder was struck by a 10 kg free flying mass. Rigid-body acceleration-time-history and the pressure at the fluid-cylinder interface were monitored during the impact event. Comparisons between the experimental results and the results of a computational model were made. The computational model used is a two-dimensional finite difference code simulating the physical experiment. The code incorporates a thin layer of air and the potential for vaporization along the inside of the cylinder. The study indicates that during a severe impact to the human head, the stresses generated within the brain can result in cavitation on the far side of impact followed by a sudden cavity collapse which can be quite violent. The study identifies how a skull-brain interface and cavitation can potentially affect the internal pressure response of the brain when subjected to a sudden impact.

  9. Cavitation dispersion of carbon nanotubes and modification of cement systems

    Directory of Open Access Journals (Sweden)

    GUSEV Boris Vladimirovich

    2014-12-01

    Full Text Available The most common research areas in construction material science deals with the development of new efficient methods to increase strength properties of materials. One of such methods is modification of composite matrices with carbon nanotubes. The characteristics of nanomodified concretes to a great extent depend on selected method of introduction of carbon nanotubes into material. The predispersion of CNT in mixing water with plasticizing additive through ultrasound impact on the environment with colloid and other types of particles including nanoparticles is the most frequently used scientific method which provides even distribution of nanoparticles in cement. In some works the separation of agglomerated CNT in suspension was conducted by means of ultrasound treatment. The further analysis showed that the main drawbacks of ultrasound dispersion are high energy output and low performance. That causes inconvenience for application of them in manufacturing process. The methods of cavitation dispersion which were developed in the late 90ies in the XXI century today are becoming commonly used in practice. The work presents the results of dispersion of multi-layer nanotubes performed on the hydrodynamic cavitation equipment. It was determined that the use of such equipment makes it possible to produce stable and even carbon dispersions and to introduce and distribute them uniformly in concrete in the same way as in the case when ultrasound treatment is performed. The advantages of this technology are considerable decrease of energy consumption and possibility to treat enormous amounts of liquids which are necessary for modification of concrete in real production process.

  10. Intensification of biogas production using pretreatment based on hydrodynamic cavitation.

    Science.gov (United States)

    Patil, Pankaj N; Gogate, Parag R; Csoka, Levente; Dregelyi-Kiss, Agota; Horvath, Miklos

    2016-05-01

    The present work investigates the application of hydrodynamic cavitation (HC) for the pretreatment of wheat straw with an objective of enhancing the biogas production. The hydrodynamic cavitation reactor is based on a stator and rotor assembly. The effect of three different speeds of rotor (2300, 2500, 2700 rpm), wheat straw to water ratios (0.5%, 1% and 1.5% wt/wt) and also treatment times as 2, 4 and 6 min have been investigated in the work using the design of experiments (DOE) approach. It was observed that the methane yield of 31.8 ml was obtained with untreated wheat straw whereas 77.9 ml was obtained with HC pre-treated wheat straw confirming the favourable changes during the pre-treatment. The combined pre-treatment using KOH and HC gave maximum yield of biogas as 172.3 ml. Overall, it has been established that significant enhancement in the biogas production can be obtained due to the pretreatment using HC which can also be further intensified by combination with chemical treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Interstitial Matrix Prevents Therapeutic Ultrasound From Causing Inertial Cavitation in Tumescent Subcutaneous Tissue.

    Science.gov (United States)

    Koulakis, John P; Rouch, Joshua; Huynh, Nhan; Dubrovsky, Genia; Dunn, James C Y; Putterman, Seth

    2018-01-01

    We search for cavitation in tumescent subcutaneous tissue of a live pig under application of pulsed, 1-MHz ultrasound at 8 W cm -2 spatial peak and pulse-averaged intensity. We find no evidence of broadband acoustic emission indicative of inertial cavitation. These acoustic parameters are representative of those used in external-ultrasound-assisted lipoplasty and in physical therapy and our null result brings into question the role of cavitation in those applications. A comparison of broadband acoustic emission from a suspension of ultrasound contrast agent in bulk water with a suspension injected subcutaneously indicates that the interstitial matrix suppresses cavitation and provides an additional mechanism behind the apparent lack of in-vivo cavitation to supplement the absence of nuclei explanation offered in the literature. We also find a short-lived cavitation signal in normal, non-tumesced tissue that disappears after the first pulse, consistent with cavitation nuclei depletion in vivo. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  12. Efficient inactivation of MS-2 virus in water by hydrodynamic cavitation.

    Science.gov (United States)

    Kosel, Janez; Gutiérrez-Aguirre, Ion; Rački, Nejc; Dreo, Tanja; Ravnikar, Maja; Dular, Matevž

    2017-11-01

    The aim of this study was to accurately quantify the impact of hydrodynamic cavitation on the infectivity of bacteriophage MS2, a norovirus surrogate, and to develop a small scale reactor for testing the effect of hydrodynamic cavitation on human enteric viruses, which cannot be easily prepared in large quantities. For this purpose, 3 mL scale and 1 L scale reactors were constructed and tested. Both devices were efficient in generating hydrodynamic cavitation and in reducing the infectivity of MS2 virus. Furthermore, they reached more than 4 logs reductions of viral infectivity, thus confirming the scalability of hydrodynamic cavitation for this particular application. As for the mechanism of page inactivation, we suspect that cavitation generated OH - radicals formed an advanced oxidation process, which could have damaged the host's recognition receptors located on the surface of the bacteriophage. Additional damage could arise from the high shear forces inside the cavity. Moreover, the effectiveness of the cavitation was higher for suspensions containing low initial viral titers that are in similar concentration to the ones found in real water samples. According to this, cavitation generators could prove to be a useful tool for treating virus-contaminated wastewaters in the future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Ultrasonic cavitation erosion of gas nitrided Ti-6Al-4V alloys.

    Science.gov (United States)

    Mitelea, I; Dimian, E; Bordeaşu, I; Crăciunescu, C

    2014-07-01

    Ultrasonic cavitation erosion experiments were performed on Ti-6Al-4V alloys samples in annealed, nitrided and nitrided and subsequently heat treated state. The protective oxide layer formed as a result of annealing and heat treatment after nitriding is eliminated after less than 30 min cavitation time, while the nitride layer lasts up to 90 min cavitation time. Once the protective layer is removed, the cavitation process develops by grain boundary erosion, leading to the expulsion of grains from the surface. The gas nitrided Ti-6Al-4V alloy, forming a TixN surface layer, proved to be a better solution to improve the cavitation erosion resistance, compared to the annealed and nitrided and heat treated state, respectively. The analysis of the mean depth of erosion rate at 165 min cavitation time showed an improvement of the cavitation erosion resistance of the nitrided samples of up to 77% higher compared to the one of the annealed samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Investigation of Microbubble Cavitation-Induced Calcein Release from Cells In Vitro.

    Science.gov (United States)

    Maciulevičius, Martynas; Tamošiūnas, Mindaugas; Jakštys, Baltramiejus; Jurkonis, Rytis; Venslauskas, Mindaugas Saulius; Šatkauskas, Saulius

    2016-12-01

    In the present study, microbubble (MB) cavitation signal analysis was performed together with calcein release evaluation in both pressure and exposure duration domains of the acoustic field. A passive cavitation detection system was used to simultaneously measure MB scattering and attenuation signals for subsequent extraction efficiency relative to MB cavitation activity. The results indicate that the decrease in the efficiency of extraction of calcein molecules from Chinese hamster ovary cells, as well as cell viability, is associated with MB cavitation activity and can be accurately predicted using inertial cavitation doses up to 0.18 V × s (R 2  > 0.9, p cavitation in the sono-extraction process. To our knowledge, this study is the first to (i) investigate small molecule extraction from cells via sonoporation and (ii) relate the extraction process to the quantitative characteristics of MB cavitation acoustic spectra. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart.

    Science.gov (United States)

    Lee, Hwansung; Taenaka, Yoshiyuki; Kitamura, Soichiro

    2005-01-01

    Until now, we have estimated cavitation for mechanical heart valves (MHV) mounted in an electrohydraulic total artificial heart (EHTAH) with tap water as a working fluid. However, tap water at room temperature is not a proper substitute for blood at 37 degrees C. We therefore investigated MHV cavitation using a glycerin solution that was identical in viscosity and vapor pressure to blood at body temperature. In this study, six different kinds of monoleaflet and bileaflet valves were mounted in the mitral position in an EHTAH, and we investigated the mechanisms for MHV cavitation. The valve closing velocity, pressure drop measurements, and a high-speed video camera were used to investigate the mechanism for MHV cavitation and to select the best MHV for our EHTAH. The closing velocity of the bileaflet valves was slower than that of the monoleaflet valves. Cavitation bubbles were concentrated on the edge of the valve stop and along the leaflet tip. It was established that squeeze flow holds the key to MHV cavitation in our study. Cavitation intensity increased with an increase in the valve closing velocity and the valve stop area. With regard to squeeze flow, the Björk-Shiley valve, because it is associated with slow squeeze flow, and the bileaflet valve with low valve closing velocity and small valve stop areas are better able to prevent blood cell damage than the monoleaflet valves.

  16. Investigation on Hydrodynamic Cavitation of a Restriction Orifice and Static Mixer on Crud-like Deposits

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Man; Lee, Seung Won; Park, Seong Dae; Kang, Sa Rah; Seo, Han; Bang, In Cheol [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2012-05-15

    Axial Offset Anomaly (AOA) referring to an unexpected neutron flux depression is also known as Crud Induced Power Shift (CIPS). Fuel assemblies removed from an AOA core have shown a thick porous deposition layer of crud on fuel clad surface. The deposition layer was induced by precipitation reactions of both boron species and crud during sub-cooled nucleate boiling. Therefore, to resolve the AOA issues, a fuel cleaning technology using ultrasonic cavitation has been developed by EPRI and applied to the domestic NPPs by KNF. However, the performance of crud removal during maintenance of NPPs is known to be not enough. Hydrodynamic cavitation is the process of vaporization, bubble generation and bubble implosion which occurs in a flowing liquid as a result of decrease and subsequent increase in pressure. Hydrodynamic cavitation generates shock pressure of a few tens MPa due to bubble collapse like the cavitation generated by Ultrasonics. It is well known that the cavitation can erode the metal surface. The idea of the current study is that such energetic cavitation bubble collapses could help to remove the crud from the fuel assembly. Therefore, the current study first investigates effects of hydrodynamic cavitation occurred from a single hole orifice and static mixer fundamentally

  17. Numerical simulation of cavitation effects influenced by centrifugal pump inlet parameters

    Science.gov (United States)

    Zhao, L. F.; Wang, Y.; Ning, C.; Liu, Z. C.; Zhu, Z. T.; Xie, S. F.

    2015-01-01

    Cavitation has great influence on performance of the centrifugal pump. However, there is still no effective design to overcome this problem. Blade leading edge of centrifugal pump impeller is the initial position of cavitation. The leading edge geometry shape not only has a great influence on the cavitation inception and its development, but also a great influence on the flow state near the impeller inlet. In this paper, the numerical simulation method is adopted. Cavitation of four different models (including rectangular-shape blade model, circular-arc-shape blade model, elliptical-shape blade model and cusp-shape blade model) are simulated under the same condition by changing the NPSHA value. The influence of different blade models on cavitation performance is analyzed. The results show that the deviation between the simulated data and experimental data is within the deviation range. The head of rectangular-shape blade model and circular-arc-shape blade model are higher than those of elliptical-shape blade model and cusp-shape blade model. However, the head of rectangular-shape blade model and circular-arc-shape blade model is smaller than the latter under the low effective cavitation margin. What's more, the head of the models with trimmed blade are higher than the head of the models with untrimmed blade under the working condition but are smaller under the low effective cavitation margin.

  18. Numerical studies in a centrifugal pump with the improved blade considering cavitation

    Science.gov (United States)

    Song, P. F.; Zhang, Y. X.; Xu, C.; Zhou, X.; Zhang, J. Y.

    2015-01-01

    In this paper, a centrifugal pump with the improved blade for cavitation is studied numerically. A 3D impeller with logarithmic spiral blade profile was designed by the in-house hydraulic design code using a centrifugal pump geometric parameters, and the blade profile curve of suction side on the designed impeller is replaced by a combination of tangent line and circle arc line. The cavitation flows in the centrifugal pump with designed impeller, modified impeller and centrifugal pump spectrum impeller are respectively calculated by two-phase CFD simulation at three flow rates. The tests of the centrifugal pump have been conducted to verify numerical simulation. The effects of designed impeller and modified impeller on hydraulic efficiency, critical cavitation number, cavitation length, head drop performance and vapor cavity distribution in impeller are investigated. The results show that the modification of blade profile curve of suction side can improve the cavitation performance of an impeller and hydraulic efficiency of centrifugal pump. Compared with designed impeller, the critical cavitation number of centrifugal pump with modified impeller decrease by 26.5% under the same flow rate coefficient, and the cavitation intensity in the modified impeller is weakened effectively. The hydraulic efficiency of modified impeller also increases by 4.9%.

  19. Cavitation in centrifugal pump with rotating walls of axial inlet device

    Science.gov (United States)

    Moloshnyi, O.; Sotnyk, M.

    2017-08-01

    The article deals with the analysis of cavitation processes in the flowing part of the double entry centrifugal pump. The analysis is conducted using numerical modeling of the centrifugal pump operating process in the software environment ANSYS CFX. Two models of the axial inlet device is researched. It is shaped by a cylindrical section and diffuser section in front of the impeller, which includes fairing. The walls of the axial inlet device rotate with the same speed as the pump rotor. The numerical experiment is conducted under the condition of the flow rate change and absolute pressure at the inlet. The analysis shows that the pump has the average statistical cavitation performance. The occurrence of the cavitation in the axial inlet device is after narrowing the cross-section of flow channel and at the beginning of the diffuser section. Additional sudden expansion at the outlet of the axial inlet diffuser section does not affect the cavitation characteristics of the impeller, however, improves cavitation characteristics of the axial inlet device. For considered geometric parameters of the axial inlet device the cavitation in the impeller begins earlier than in the axial inlet device. That is, the considered design of the axial inlet device will not be subjected to destruction at the ensuring operation without cavitation in the impeller.

  20. The correlation between bubble-enhanced HIFU heating and cavitation power.

    Science.gov (United States)

    Farny, Caleb H; Glynn Holt, R; Roy, Ronald A

    2010-01-01

    It has been established that while the inherent presence of bubbles increases heat generation due to scattering and absorption, inertial cavitation is responsible for elevated heating during high-intensity focused ultrasound (HIFU) application. The contribution of bubble-induced heating can be an important factor to consider, as it can be several times greater than the expected heat deposition from absorption of energy from the primary ultrasound field. The temperature and cavitation signal near the focus were measured for 5.5-s continuous-wave 1.1-MHz HIFU sonications in tissue mimicking phantoms. The measured temperature was corrected for heating predicted from the primary ultrasound absorption to isolate the temperature rise from the bubble activity. The temperature rise induced from cavitation correlates well with a measurement of the instantaneous "cavitation power" as indicated by the mean square voltage output of a 15-MHz passive cavitation detector. The results suggest that careful processing of the cavitation signals can serve as a proxy for measuring the heating contribution from inertial cavitation.

  1. Transient cavitation in high-quality-factor resonators at high static pressures.

    Science.gov (United States)

    Gaitan, D Felipe; Tessien, Ross A; Hiller, Robert A; Gutierrez, Joel; Scott, Corey; Tardif, Henry; Callahan, Brant; Matula, Thomas J; Crum, Lawrence A; Holt, R Glynn; Church, Charles C; Raymond, Jason L

    2010-06-01

    It is well known that cavitation collapse can generate intense concentrations of mechanical energy, sufficient to erode even the hardest metals and to generate light emissions visible to the naked eye [sonoluminescence (SL)]. Considerable attention has been devoted to the phenomenon of "single bubble sonoluminescence" (SBSL) in which a single stable cavitation bubble radiates light flashes each and every acoustic cycle. Most of these studies involve acoustic resonators in which the ambient pressure is near 0.1 MPa (1 bar), and with acoustic driving pressures on the order of 0.1 MPa. This study describes a high-quality factor, spherical resonator capable of achieving acoustic cavitation at ambient pressures in excess of 30 MPa (300 bars). This system generates bursts of violent inertial cavitation events lasting only a few milliseconds (hundreds of acoustic cycles), in contrast with the repetitive cavitation events (lasting several minutes) observed in SBSL; accordingly, these events are described as "inertial transient cavitation." Cavitation observed in this high pressure resonator is characterized by flashes of light with intensities up to 1000 times brighter than SBSL flashes, as well as spherical shock waves with amplitudes exceeding 30 MPa at the resonator wall. Both SL and shock amplitudes increase with static pressure.

  2. Characterizing cryogenic propellant flow behavior through a cavitating venturi in comparison to alternative flow control mechanisms

    Science.gov (United States)

    Ingle, Marjorie Adele

    The work detailed is an investigation of the use of a cavitating venturi as both a flow control and metering device. This was achieved through the combination of actual experimentation and numerical modeling of the fluid behavior of both liquid water and liquid methane as it passes through the test article designed, developed, and validated here within this study. The discharge coefficient of the cavitating venturi was determined through weigh flow calibration testing to determine an average mass flow rate. Turbine flow meter flow rate readings were used as a point of comparison and the discharge coefficient was computed. The discharge coefficient was then implemented into the Bernoulli Equation along with experimental pressure and temperature data to again calculate mass flow rate through the cavitating venturi. The agreement of the venturi flow rate data to that of the turbine flow meter effectively established its applicability as a passive flow control and metering feature. A preliminary CFD cavitation model was developed and validated for cavitating water flow regimes using ANSYS FLUENT. Agreement between mass flow rates obtained from the model to experimental data for cavitating water flow indicates that deviations in results for liquid methane analysis from experimental results could simply be the result of insufficiently defined fluid characteristics in the ANSYS FLUENT materials database. SEM surface roughness analysis of a secondary test article indicated that the default average surface roughness for steel in ANSYS FLUENT was reasonable. In addition, the methodology could be further applied to future duty life studies for the cavitating venturi flow meter.

  3. Elastomeric impression as a diagnostic method of cavitation in proximal dentin caries in primary molars

    Directory of Open Access Journals (Sweden)

    Adriela Azevedo Souza Mariath

    2007-12-01

    Full Text Available The purpose of this study was to validate the elastomeric impression after temporary tooth separation as a method of cavitation detection in proximal caries lesions in primary molars with outer half dentin radiolucency. Fifty-one children (4-10 years old, presenting radiolucency in the outer half of the dentin at the proximal surfaces of primary molars and proximal anatomic contact with the adjacent tooth (without restoration/cavitated caries lesion were enrolled in the study. Temporary tooth separation was performed with an orthodontic rubber ring placed around the contact point during 2-3 days. Thereafter, impression of the proximal surfaces was made. The elastomeric impressions were classified as "non-cavitated" or "cavitated" surfaces. Visual inspection after tooth separation was considered as the gold standard. Examiner reliability of visual inspection after tooth separation was determined (kappa 0.92. Impression examination was repeated every 5 participants to evaluate the reproducibility of the method. The frequency of cavitated lesions was 65%, and 67% of those were inactive. Sensitivity, specificity, positive and negative predictive values were 0.88% (95%CI 0.73-0.95, 0.89% (95%CI 0.67-0.97, 0.94% (95%CI 0.79-0.98 and 0.80% (95%CI 0.58-0.92, respectively. Impression examination showed total agreement regarding cavitation. The evaluation of elastomeric impression after tooth separation is a useful clinical resource in cavitation detection for clinicians and researchers when visual inspection is doubtful.

  4. Combined treatment technology based on synergism between hydrodynamic cavitation and advanced oxidation processes.

    Science.gov (United States)

    Gogate, Parag R; Patil, Pankaj N

    2015-07-01

    The present work highlights the novel approach of combination of hydrodynamic cavitation and advanced oxidation processes for wastewater treatment. The initial part of the work concentrates on the critical analysis of the literature related to the combined approaches based on hydrodynamic cavitation followed by a case study of triazophos degradation using different approaches. The analysis of different combinations based on hydrodynamic cavitation with the Fenton chemistry, advanced Fenton chemistry, ozonation, photocatalytic oxidation, and use of hydrogen peroxide has been highlighted with recommendations for important design parameters. Subsequently degradation of triazophos pesticide in aqueous solution (20 ppm solution of commercially available triazophos pesticide) has been investigated using hydrodynamic cavitation and ozonation operated individually and in combination for the first time. Effect of different operating parameters like inlet pressure (1-8 bar) and initial pH (2.5-8) have been investigated initially. The effect of addition of Fenton's reagent at different loadings on the extent of degradation has also been investigated. The combined method of hydrodynamic cavitation and ozone has been studied using two approaches of injecting ozone in the solution tank and at the orifice (at the flow rate of 0.576 g/h and 1.95 g/h). About 50% degradation of triazophos was achieved by hydrodynamic cavitation alone under optimized operating parameters. About 80% degradation of triazophos was achieved by combination of hydrodynamic cavitation and Fenton's reagent whereas complete degradation was achieved using combination of hydrodynamic cavitation and ozonation. TOC removal of 96% was also obtained for the combination of ozone and hydrodynamic cavitation making it the best treatment strategy for removal of triazophos. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Clinical significance of tumor cavitation in surgically resected early-stage primary lung cancer.

    Science.gov (United States)

    Tomizawa, Kenji; Shimizu, Shigeki; Ohara, Shuta; Fujino, Toshio; Nishino, Masaya; Sesumi, Yuichi; Kobayashi, Yoshihisa; Sato, Katsuaki; Chiba, Masato; Shimoji, Masaki; Suda, Kenichi; Takemoto, Toshiki; Mitsudomi, Tetsuya

    2017-10-01

    The prognostic impact of tumor cavitation is unclear in patients with early-stage primary lung cancer. The aim of the present study was to examine the clinicopathological features and prognoses of patients with pathological stage I-IIA (p-stage I-IIA) primary lung cancers harboring tumor cavitation. This study was conducted according to the eighth edition of the TNM classification for lung cancer. We examined 602 patients with p-stage I-IIA primary lung cancer out of 890 patients who underwent pulmonary resection from January 2007 through March 2014 and searched for the presence of tumor cavitation, which is defined as the presence of air space within the primary tumor. A total of 59 out of the 602 patients had tumor cavitation (10%). Compared with patients without tumor cavitation, those with tumor cavitation had a significantly higher frequency of the following characteristics: high serum carcinoembryonic antigen (CEA) level (≥5ng/ml, p=0.027), interstitial pneumonia (p=0.0001), high SUVmax value on FDG-PET scan (≥4.2, p=0.023), tumors located in the lower lobe (p=0.024), large tumor size (>3cm, p=0.002), vascular invasion (66% vs 17%, pcavitation was significantly shorter than that of patients without tumor cavitation (log-rank test: pcavitation was found to be an independent and significant factor associated with poor prognosis in the multivariate analysis (hazard ratio: 1.76, 95% confidence interval: 1.02-3.10, p=0.042). Tumor cavitation is an independent factor for poor prognosis in patients with resected p-stage I-IIA primary lung cancer. Based on our analyses, patients with tumor cavitation should be regarded as a separate cohort that requires more intensive follow-up. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Effect of ultrasound on dynamics characteristic of the cavitation bubble in grinding fluids during honing process.

    Science.gov (United States)

    Guo, Ce; Zhu, Xijing

    2018-03-01

    The effect of ultrasound on generating and controlling the cavitation bubble of the grinding fluid during ultrasonic vibration honing was investigated. The grinding fluid on the surface of the honing stone was measured by utilizing the digital microscope VHX-600ESO. Based on analyzing the cavitation mechanism of the grinding fluid, the bubble dynamics model under conventional honing (CH) and ultrasonic vibration honing (UVH) was established respectively. Difference of dynamic behaviors of the bubble between the cases in UVH and CH was compared respectively, and the effects of acoustic amplitude and ultrasonic frequency on the bubble dynamics were simulated numerically using the Runge-Kutta fourth order method with variable step size adaptive control. Finally, the cavitation intensity of grinding fluids under ultrasound was measured quantitatively using acoustimeter. The results showed that the grinding fluid subjected to ultrasound can generate many bubbles and further forms numerous groups of araneose cavitation bubbles on the surface of the honing stone. The oscillation of the bubble under UVH is more intense than the case under CH, and the maximum velocity of the bubble wall under UVH is higher two magnitudes than the case under CH. For lower acoustic amplitude, the dynamic behaviors of the bubble under UVH are similar to that case under CH. As increasing acoustic amplitude, the cavitation intensity of the bubble is growing increased. Honing pressure has an inhabitation effect on cavitation effect of the grinding fluid. The perfect performance of cavitation of the grinding fluid can be obtained when the device of UVH is in the resonance. However, the cavitation intensity of the grinding fluid can be growing weakened with increasing ultrasonic frequency, when the device of UVH is in the off-resonance. The experimental results agree with the theoretical and numerical analysis, which provides a method for exploring applications of the cavitation effect in

  7. Numerical Prediction of Tip Vortex Cavitation for Marine Propellers in Non-uniform Wake

    Science.gov (United States)

    Zhu, Zhi-Feng; Zhou, Fang; Li, Dan

    2017-07-01

    Tip vortex cavitation is the first type of cavitation to take place around most marine propellers. But the numerical prediction of tip vortex cavitation is one of the challenges for propeller wake because of turbulence dissipation during the numerical simulation. Several parameters of computational mesh and numerical algorithm are tested by mean of the predicted length of tip vortex cavtiation to validate a developed method. The predicted length of tip vortex cavtiation is on the increase about 0.4 propeller diameters using the developed numerical method. The predicted length of tip vortex cavtiation by RNG k - ɛ model is about 3 times of that by SST k - ω model. Therefore, based on the validation of the present approach, the cavitating flows generated by two rotating propellers under a non-uniform inflow are calculated further. The distributions of axial velocity, total pressure and vapor volume fraction in the transversal planes across tip vortex region are shown to be useful in analyzing the feature of the cavitating flow. The strongest kernel of tip vortex cavitation is not at the position most close to blade tip but slightly far away from the region. During the growth of tip vortex cavitation extension, it appears short and thick, and then it becomes long and thin. The pressure fluctuations at the positions inside tip vortex region also validates the conclusion. A key finding of the study is that the grids constructed especially for tip vortex flows by using separated computational domain is capable of decreasing the turbulence dissipation and correctly capturing the feature of propeller tip vortex cavitation under uniform and non-uniform inflows. The turbulence model and advanced grids is important to predict tip vortex cavitation.

  8. The Cavitation With Plate Transducer And Non Cavitation With Knob Transducer By Manihot Utilissima Fermentation The Potential Hydrogen Ph Method

    Directory of Open Access Journals (Sweden)

    Syamsul Arifin

    2015-08-01

    Full Text Available Abstract Manihot M. utilissima fermentation is popular foods and drinks for Indonesia people but it fermented foods 24 hours per day will breed fungi and anaerobic bacteriae so it will make it into acidic foods and alcoholic beverages. Ultrasonic 48 kHz 5 Vpp 1 VDC with functional generator and of the two models of transducers will have two different phenomena on M. utilissima fermentation. Methods Model-1. Radiation ultrasonic transducer plate or Flat of piezoelectric speakers2 were applied with transducers M. utilissima dipped in a test tube. Model-2. Knob or small ball ultrasonic transducer 12 balls were applied with transducers of tin knob which was connected to the copper wire2 and piezoelectricspeakers were dipped into the media M. utilissima in a test tube. After ultrasonic radiation fluid liquid from two models of transducers measured total acid in M. utilissima fermentation liquid by paper indicators of potential Hydrogen pH. The conclusion of this study can predict different phenomena namely the transducer plate of the initial pH value-acid fermentation M. utilissima can change increases the pH-value end of the base which means that the transducer plate has a cavitation phenomenon and media M. utilissima lead to the delicious food but on transducer knob that the initial pH value-acid fermentation M. utilissima will decrease more acid value so that have no phenomenon of cavitation and the media will lead M. utilissima to be alcoholic foods.

  9. Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Camillo ANAUATE-NETTO

    Full Text Available Abstract Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL and contralateral teeth receiving Icon infiltrant (DMG. Caries progression was monitored by clinical (laser fluorescence caries detection and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>0.05. No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (p0.05. SEM analysis exhibited a more homogeneous sealing for the infiltrant than obtained by the sealant. Conclusions The infiltrant was effective to prevent the caries progression in non-cavitated pit-and-fissures after 3 years of clinical evaluation, comparable with the conventional sealant. The infiltrant also presented better results in terms of caries progression at the 3-year evaluation time using the radiographic analysis.

  10. Structural determinants of increased susceptibility to dehydration-induced cavitation in post-fire resprouting chaparral shrubs.

    Science.gov (United States)

    Jacobsen, Anna L; Tobin, Michael F; Toschi, Hayden S; Percolla, Marta I; Pratt, R Brandon

    2016-11-01

    It is well established that transpiration and photosynthetic rates generally increase in resprouting shoots after fire in chaparral shrublands. By contrast, little is known about how plant hydraulic function varies during this same recovery period. We hypothesized that vascular traits, both functional and structural, would also shift in order to support this heightened level of gas exchange and growth. We examined stem xylem-specific hydraulic conductivity (Ks ) and resistance to cavitation (P50 ) for eight chaparral shrub species as well as several potential xylem structural determinants of hydraulic function and compared established unburned plants and co-occurring post-fire resprouting plants. Unburned plants were generally more resistant to cavitation than resprouting plants, but the two groups did not differ in Ks . Resprouting plants had altered vessel structure compared with unburned plants, with resprouting plants having both wider diameter vessels and higher inter-vessel pit density. For biomechanics, unburned plants had both stronger and denser stem xylem tissue than resprouting plants. Shifts in hydraulic structure and function resulted in resprouting plants being more vulnerable to dehydration. The interaction between time since disturbance (i.e. resprouting versus established stands) and drought may complicate attempts to predict mortality risk of resprouting plants. © 2016 John Wiley & Sons Ltd.

  11. Cavitation controlled acoustic probe for fabric spot cleaning and moisture monitoring

    Science.gov (United States)

    Sheen, Shuh-Haw; Chien, Hual-Te; Raptis, Apostolos C.

    1997-01-01

    A method and apparatus are provided for monitoring a fabric. An acoustic probe generates acoustic waves relative to the fabric. An acoustic sensor, such as an accelerometer is coupled to the acoustic probe for generating a signal representative of cavitation activity in the fabric. The generated cavitation activity representative signal is processed to indicate moisture content of the fabric. A feature of the invention is a feedback control signal is generated responsive to the generated cavitation activity representative signal. The feedback control signal can be used to control the energy level of the generated acoustic waves and to control the application of a cleaning solution to the fabric.

  12. An improved method to identify grain boundary creep cavitation in 316H austenitic stainless steel.

    Science.gov (United States)

    Chen, B; Flewitt, P E J; Smith, D J; Jones, C P

    2011-04-01

    Inter-granular creep cavitation damage has been observed in an ex-service 316H austenitic stainless steel thick section weldment. Focused ion beam cross-section milling combined with ion channelling contrast imaging is used to identify the cavitation damage, which is usually associated with the grain boundary carbide precipitates in this material. The results demonstrate that this technique can identify, in particular, the early stage of grain boundary creep cavitation unambiguously in materials with complex phase constituents. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Elastic cavitation, tube hollowing, and differential growth in plants and biological tissues

    KAUST Repository

    Goriely, A.

    2010-07-01

    Elastic cavitation is a well-known physical process by which elastic materials under stress can open cavities. Usually, cavitation is induced by applied loads on the elastic body. However, growing materials may generate stresses in the absence of applied loads and could induce cavity opening. Here, we demonstrate the possibility of spontaneous growth-induced cavitation in elastic materials and consider the implications of this phenomenon to biological tissues and in particular to the problem of schizogenous aerenchyma formation. Copyright © EPLA, 2010.

  14. Methods for Cavitation Prediction on Tip-Modified Propellers in Ship Wake Fields

    DEFF Research Database (Denmark)

    Shin, Keun Woo; Regener, Pelle Bo; Andersen, Poul

    2015-01-01

    Unsteady cavitation simulations on a tip-modified propellerin behind-hull condition are made by both BoundaryElement Method (BEM) and Computational FluidDynamics (CFD).As the hull geometry typically is not disclosed to thepropeller designer and thus cannot be included in thesimulation, other...... types of hullwake fields: One originating from model test measurementsand the other from a bare hull RANS simulation at thecavitation test Reynolds number. By comparing simulationresults, the different numerical approaches are evaluated foraccuracy of the unsteady cavitation prediction...... as a propellerdesign tool complementing the cavitation tunnel test....

  15. Predicting Cavitation on Marine and Hydrokinetic Turbine Blades with AeroDyn V15.04

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Robynne [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-14

    Cavitation is an important consideration in the design of marine and hydrokinetic (MHK) turbines. The National Renewable Energy Laboratory's AeroDyn performance code was originally developed for horizontal-axis wind turbines and did not have the capability to predict cavitation inception. Therefore, AeroDyn has been updated to include the ability to predict cavitation on MHK turbines based on user-specified vapor pressure and submerged depth. This report outlines a verification of the AeroDyn V15.04 performance code for MHK turbines through a comparison to publicly available performance data.

  16. Modeling the effect of carbon-dioxide gas on cavitation.

    Science.gov (United States)

    Gireesan, Subash; Pandit, Aniruddha B

    2017-01-01

    One of the controlling parameters of the physical and chemical effects produced by acoustic cavitation is the use of dissolved gas as it affects the temperature and pressure obtained at cavity collapse and, the reactions happening in a bubble. It also enhances the nucleation rates by decreasing the threshold required for cavitation by providing dissolved gas nuclei. The present study looks into the effect of carbon dioxide gas on cavitation using a diffusion limited model. The model couples the dynamics of a single bubble with 11 chemical reactions involving 8 reactive species. The effect of mass transport (diffusion of water vapor and radical species) and heat transport (by conduction) is included in the model. Simulations were carried out for different initial compositions of an Ar-CO2- bubble and the results were compared with an experimental study reported in the earlier literature. The results have indicated that intensity of collapse decreases with an increase in CO2 composition in the bubble thereby decreasing the yield of the oxidizing radicals like OH. This is due to the lower polytropic coefficient and higher specific heat of CO2 compared to that of argon. Also, the bubbles grows to a larger extent with an increase in the dissolved CO2 concentration thereby accommodating higher amounts of water vapor and ultimately decreasing the temperature obtained at collapse. Simulations were done for a bubble containing a mole fraction of 95% Ar and 5% CO2 at different values of driving frequencies (213, 355, 647 and 1000kHz) and driving pressure amplitudes (3.22, 5, 7.5 and 10bar). Higher production rate of OH radicals was predicted at a lower driving frequency, for a given driving pressure amplitude and it increased with an increase in the driving pressure amplitude. At a given driving pressure amplitude, the yield of OH radicals decreased with an increase in the CO2 concentration in the bubble for all the driving frequencies used in the simulations. Copyright

  17. Power spectrum of fluctuation for ultrasonic cavitation process in glycerin

    Science.gov (United States)

    Skokov, V. N.; Koverda, V. P.; Reshetnikov, A. V.; Vinogradov, A. V.

    2007-03-01

    Experiments were carried out on ultrasonic cavitation in glycerin. The zone near the emitter has a structure from interacting gas-vapor bubbles; this structure takes the form of fractal clusters. The photometry of passed laser emission was the tool for studying dynamics of fluctuations. In transitive mode, the power spectrum of fluctuation varies by the law inversely proportional to frequency. Distributions of local fluctuations are different from Gaussian and exhibit the property of scale invariance. The qualitative behavior of the frequency dependence of the spectral fluctuation density was tested while varying the power of the ultrasonic emitter. It was demonstrated that the growth of the high-frequency margin of flicker-type behavior evidences for growing instability and can be considered as a forerunner of possible large-scale outbursts.

  18. Cavitation at migrating boundaries during high temperature fatigue

    Energy Technology Data Exchange (ETDEWEB)

    Raman, V.

    1987-06-01

    There is growing interest in the role of migrating boundaries during high temperature deformation. One area of current interest is the manner in which grain boundary migration can influence deformation and fracture at elevated temperatures. Much of the detailed treatments of intergranular cracking and cavitation during creep deformation have centered on effects occurring at stationary grain boundaries. The conventional idea represented in numerous publications is that grain boundary sliding plays an important role in intergranular fracture at elevated temperatures. The large stress concentrations developed at irregularities on grain boundaries are frequently cited as the principal reason for the easy generation of cracks and cavities. This article concludes that high temperature fatigue can cause significant migration and sliding in Al-3% Mg and Pb-2% Sn solid solution alloys, and that microcavitation and cracking takes place at the migrating boundaries in specimens tested at large strain amplitudes and low test frequencies. Cavities may be isolated within grains due to boundary migration.

  19. Cavitation Bubble Dynamics in Ammoniacal Fluids Transferred by Centrifugal Pumps

    Directory of Open Access Journals (Sweden)

    Jorge Reyes-Cruz

    2016-10-01

    Full Text Available An experiment with water and ammoniacal liquor at 27% and 34% concentrations of ammonia was carried out in order to determine the pressure dynamics during the formation of bubbles and their movement when causing cavitations in centrifugal pumps. The dynamics of bubbles was calculated numerically by applying the Rayleigh-Plesset equation using the bubble radius and the bubble build-up time. It is concluded that the pressure to form the bubbles at 22 ºC is 10,135.103 Pa for water and 45,468.103 Pa for the ammoniacal liquor at a concentration of 34 %. The radius of the bubbles found in ammoniacal liquor is in the range of 30 to 120 times the original bubble radius while the bubbles formed in water are only in the range of 15 times the original radius value.

  20. Shockwave and cavitation bubble dynamics of atmospheric air

    Directory of Open Access Journals (Sweden)

    Leela Ch.

    2013-11-01

    Full Text Available The generation and evolution of laser induced shock waves (SWs and the hot core plasma (HCP created by focusing 7 ns, 532 nm laser pulses in ambient air is studied using time resolved shadowgraphic imaging technique. The dynamics of rapidly expanding plasma releasing SWs into the ambient atmosphere were studied for time delays ranging from nanoseconds to milliseconds with ns temporal resolution. The SW is observed to get detached from expanding HCP at around 3μs. Though the SWs were found to expand spherically following the Sedov-Taylor theory, the rapidly expanding HCP shows asymmetric expansion during both the expansion and cooling phase similar to that of inertial cavitation bubble (CB dynamics. The asymmetric expansion of HCP leads to oscillation of the plasma boundary, eventually leading to collapse by forming vortices formed by the interaction of ambient air.

  1. Numerical study on cavitating flow due to a hydrofoil near a free surface

    Directory of Open Access Journals (Sweden)

    Ping-Chen Wu

    2016-09-01

    Full Text Available A numerical strategy is proposed for a viscous uniform flow past a 2-D partially cavitating hydrofoil placed at a finite depth from the free surface. The flow was modeled by the Reynolds-averaged Navier–Stokes (RANS equations. A finite-volume method with the SIMPLE scheme and k-ε turbulence model were employed for computations. The “full cavitation model,” which included the effects of vaporization, noncondensible gases and compressibility, was incorporated in the computation of cavitating flow. The cavity shape and free surface were updated iteratively till a reasonable convergence was reached. As for the determination of the free surface, the VOF approach was adopted. The test cases show the accuracy and stability of our procedure to capture the cavitating flow near the free surface.

  2. Anatomical regulation of ice nucleation and cavitation helps trees to survive freezing and drought stress

    Science.gov (United States)

    Lintunen, A.; Hölttä, T.; Kulmala, M.

    2013-06-01

    Water in the xylem, the water transport system of plants, is vulnerable to freezing and cavitation, i.e. to phase change from liquid to ice or gaseous phase. The former is a threat in cold and the latter in dry environmental conditions. Here we show that a small xylem conduit diameter, which has previously been shown to be associated with lower cavitation pressure thus making a plant more drought resistant, is also associated with a decrease in the temperature required for ice nucleation in the xylem. Thus the susceptibility of freezing and cavitation are linked together in the xylem of plants. We explain this linkage by the regulation of the sizes of the nuclei catalysing freezing and drought cavitation. Our results offer better understanding of the similarities of adaption of plants to cold and drought stress, and offer new insights into the ability of plants to adapt to the changing environment.

  3. The onset of cavitation during the collision of a sphere with a wetted surface

    KAUST Repository

    Mansoor, Mohammad M.

    2014-01-01

    We investigate the onset of cavitation during the collision of a sphere with a solid surface covered with a layer of Newtonian liquid. The conventional theory dictates cavitation to initiate during depressurization, i.e. when the sphere rebounds from the solid surface. Using synchronized dual-view high-speed imaging, we provide conclusive experimental evidence that confirms this scenario- namely-that cavitation occurs only after the sphere makes initial contact with the solid surface. Similar to previous experimental observations for spheres released above the liquid surface, bubbles are formed on the sphere surface during entry into the liquid layer. These were found to squeeze radially outwards with the liquid flow as the sphere approached the solid surface, producing an annular bubble structure unrelated to cavitation. In contrast, spheres released below the liquid surface did not exhibit these patterns. © Springer-Verlag Berlin Heidelberg 2014.

  4. Experimental Investigation and Passive Flow Control of a Cavitating Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Spyridon D. Kyparissis

    2012-01-01

    Full Text Available Passive flow control techniques are used to improve the flow field and efficiency of centrifugal pumps and turbomachines, in general. An important phenomenon that mechanical engineers have to take into account is cavitation. It leads to the decrease of the pump performance and total head. In the present experimental study, a centrifugal pump is investigated in cavitating conditions. A passive flow control is realized using three different blade leading edge angles in order to reduce the cavitation development and enhance the pump performance. The experiments are carried out in a pump test rig specially designed and constructed, along with the impellers. The head drop and total efficiency curves are presented in order to examine the effect of the blade leading edge angle on the cavitation and pump performance. Finally, the vapour distribution along with the blades is illustrated for the tested blade leading edge angles.

  5. Research and development of improved cavitating jets for deep-hole drilling

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, V.E. Jr.; Lindenmuth, W.T.; Chahine, G.L.; Conn, A.F.; Frederick, G.S.

    1984-01-01

    Improved cavitating nozzles have been developed as part of an on-going program to increase the rate of penetration of deep-hole drill bits. Based on the four criteria of: incipient cavitation number, amplitude of pressure fluctuation (and hence enhanced structuring of the jet flow), rock cutting, and cleaning chips from the hole bottom - these new, STRATOJET (STRuctured Acoustically Tuned Oscillating JET) cavitating nozzle systems have out-performed both conventional drill bit nozzles and the basic CAVIJET cavitating jets. Although nozzle designs which provide large amplitude pressure modulations are now available for the operation in water, additional research is needed to optimize self-resonating jets for use: (a) in mud, (b) in specific drill bit designs, and (c) at higher system pressures than now currently used for deep-hole drilling.

  6. CFD analysis of artificial slippage and surface texturing in lubricated sliding contact considering cavitation

    Science.gov (United States)

    Pratomo, Ariawan Wahyu; Romadhon, Reza Risky; Muchammad, Tauviqirrahman, Mohammad; Jamari, J.; Bayuseno, Athanasius P.

    2017-01-01

    The present paper explores the effect of slip variation for Newtonian and non-Newtonian lubricants on textured slider bearing performance considering cavitation. Investigations are carried out by using a numerical method based on commercial CFD (computational fluid dynamic) software ANSYS for fluid flow phenomenon to assess the tribological characteristic (i.e. hydrodynamic pressure distribution) of a lubricated sliding contact. The Zwart-Gerber-Belamri model for cavitation is adopted. To model hydrophobicity, i.e. slippage, the enhanced user-defined-function (UDF) in the FLUENT® package is developed. The numerical results show that the cavitation modeling has a huge effect on the performance. Neglecting the cavitation leads to a less accurate result. Also, regarding the effect of slip variation, it is found that the single slip is the best pattern to improve the pressure profile.

  7. Histological and Ultrastructural Effects of Ultrasound-induced Cavitation on Human Skin Adipose Tissue

    Directory of Open Access Journals (Sweden)

    Daniele Bani, MD

    2013-09-01

    Conclusions: This study further strengthens the current notion that noninvasive transcutaneous ultrasound cavitation is a promising and safe technology for localized reduction of fat and provides experimental evidence for its specific mechanism of action on the adipocytes.

  8. The improvement of the surface hardness of stainless steel and aluminium alloy by ultrasonic cavitation peening

    National Research Council Canada - National Science Library

    Janka Styková; Miloš Müller; Jan Hujer

    2017-01-01

    This article presents first results of the experimental investigation of the influence of the cavitation shot less peening process on the properties of stainless steel and aluminium alloy specimens...

  9. RANS simulation of cavitation and hull pressure fluctuation for marine propeller operating behind-hull condition

    Directory of Open Access Journals (Sweden)

    Kwang-Jun Paik

    2013-12-01

    Full Text Available Simulations of cavitation flow and hull pressure fluctuation for a marine propeller operating behind a hull using the unsteady Reynolds-Averaged Navier-Stokes equations (RANS are presented. A full hull body submerged under the free surface is modeled in the computational domain to simulate directly the wake field of the ship at the propeller plane. Simulations are performed in design and ballast draught conditions to study the effect of cavitation number. And two propellers with slightly different geometry are simulated to validate the detectability of the numerical simulation. All simulations are performed using a commercial CFD software FLUENT. Cavitation patterns of the simulations show good agreement with the experimental results carried out in Samsung CAvitation Tunnel (SCAT. The simulation results for the hull pressure fluctuation induced by a propeller are also compared with the experimental results showing good agreement in the tendency and amplitude, especially, for the first blade frequency.

  10. Natural and laser-induced cavitation in corn stems: On the mechanisms of acoustic emissions

    CERN Document Server

    Fernández, E; Bilmes, G M; 10.4279/PIP.040003

    2012-01-01

    Water in plant xylem is often superheated, and therefore in a meta-stable state. Under certain conditions, it may suddenly turn from the liquid to the vapor state. This cavitation process produces acoustic emissions. We report the measurement of ultrasonic acoustic emissions (UAE) produced by natural and induced cavitation in corn stems. We induced cavitation and UAE in vivo, in well controlled and reproducible experiments, by irradiating the bare stem of the plants with a continuous-wave laser beam. By tracing the source of UAE, we were able to detect absorption and frequency filtering of the UAE propagating through the stem. This technique allows the unique possibility of studying localized embolism of plant conduits, and thus to test hypotheses on the hydraulic architecture of plants. Based on our results, we postulate that the source of UAE is a transient "cavity oscillation" triggered by the disruptive effect of cavitation inception.

  11. Effect of the probe geometry on dynamics of cavitation

    Science.gov (United States)

    Palanker, Daniel V.; Vankov, Alexander; Miller, Jason

    2002-06-01

    Cavitation bubbles accompany explosive evaporation of water after pulsed energy deposition during endosurgery. Bubbles collapsing at the time of an endo-probe produce a powerful and damaging water jet propagating forward in the axial direction of the probe. We demonstrate that formation of this flow and associated tissue damage can be prevented by application of the concave probes that slow the propagation of the back boundary of the bubble. A similar effect can be achieved by positioning an obstacle to the flow, such as a ring or a pick tip in a close proximity to the back, side or front of the tip. Dependence of the flow dynamics on geometry of the probe was studied using fast flash photography and particle velocimetry. With a flat tip a maximal jet velocity of 80 m/s is achieved at a pulse energy of 0.12 mJ, while with an optimized concave probe the jet is completely stopped. The maximal distance between the probe and the tissue at which cells were affected by the water jet was measured using choriallantoic membrane of a chick embryo and Propidium Iodide staining. Changing the tip geometry from flat or convex to an optimized concave shape resulted in reduction of the damage distance by a factor of 4 with pulse energies varying from 0.02 to 0.75 mJ. Elimination of the water jet dramatically improves precision and safety of the pulsed endosurgery reducing the axial damage zone to a size of the cavitation bubble at its maximal expansion.

  12. Phase-shift nano-emulsions induced cavitation and ablation during high intensity focused ultrasound exposure

    Science.gov (United States)

    Qiao, Yangzi; Yin, Hui; Chang, Nan; Wan, Mingxi

    2017-03-01

    Phase-shift Nano-emulsions (PSNEs) with a small initial diameter in nanoscale have the potential to leak out of the blood vessels and to accumulate at target point of tissue. At desired location, PSNEs can undergo acoustic droplet vaporization (ADV) process, change into gas bubbles and enhance focused ultrasound efficiency. The aim of this work was to provide spatial and temporal information on PSNE induced cavitation and ablation effects during pulsed high intensity focused ultrasound (HIFU) exposure. The PSNEs were composed of perfluorohaxane (PFH) and bovine serum albumin (BSA), and then uniformly distributed in a transparent polyacrylamide phantom. The Sonoluminescence (SL) method was employed to visualize the cavitation distribution and formation process of PSNEs induced cavitation. For the phantom which was used for ablation observation, heat sensitive BSA was added. When the temperature generated by ultrasound exposure was high enough to denature BSA, the transparent phantom would turn out white lesions. The shape of the lesion and the formation process were compared with those of cavitation. Each of the pulse contained 12 cycles for a duration of 10 µs. And the duty cycle changed from 1:10 to 1:40. The total "on" time of HIFU was 2s. PSNE can evidently accelerate cavitation emitting bright SL in pre-focal region. The cavitation was generated layer by layer towards the transducer. The formed bubble wall can block acoustic waves transmitting to the distal end. And the lesion appeared to be separated into two parts. One in pre-focal region stemmed from one point and grew quickly toward the transducer. The other in focal region was formed by merging some small white dots, and grew much slower. The influence of duty cycle has also been examined. The lower duty cycle with longer pulse-off time would generate more intense cavitation, however, smaller lesion. Bubble cloud gradually developed within phantom would greatly influence the cavitation and ablation

  13. Sustainable Food & Sustainable Economics

    OpenAIRE

    Alvarez, Mavis Dora

    2012-01-01

    Cuba today is immersed in a very intense process of perfecting its agricultural production structures with the goal of making them more efficient and sustainable in their economic administration and in their social and environmental management. Agricultural cooperatives in Cuba have the responsibility of producing on 73% of the country's farmland. Their contributions are decisive to developing agricultural production and to ensuring more and better food for the population, in addition to redu...

  14. Cavitation, Flow Structure and Turbulence in the Tip Region of a Rotor Blade

    Science.gov (United States)

    Wu, H.; Miorini, R.; Soranna, F.; Katz, J.; Michael, T.; Jessup, S.

    2010-01-01

    Objectives: Measure the flow structure and turbulence within a Naval, axial waterjet pump. Create a database for benchmarking and validation of parallel computational efforts. Address flow and turbulence modeling issues that are unique to this complex environment. Measure and model flow phenomena affecting cavitation within the pump and its effect on pump performance. This presentation focuses on cavitation phenomena and associated flow structure in the tip region of a rotor blade.

  15. Root resistance to cavitation is accurately measured using a centrifuge technique.

    Science.gov (United States)

    Pratt, R B; MacKinnon, E D; Venturas, M D; Crous, C J; Jacobsen, A L

    2015-02-01

    Plants transport water under negative pressure and this makes their xylem vulnerable to cavitation. Among plant organs, root xylem is often highly vulnerable to cavitation due to water stress. The use of centrifuge methods to study organs, such as roots, that have long vessels are hypothesized to produce erroneous estimates of cavitation resistance due to the presence of open vessels through measured samples. The assumption that roots have long vessels may be premature since data for root vessel length are sparse; moreover, recent studies have not supported the existence of a long-vessel artifact for stems when a standard centrifuge technique was used. We examined resistance to cavitation estimated using a standard centrifuge technique and compared these values with native embolism measurements for roots of seven woody species grown in a common garden. For one species we also measured vulnerability using single-vessel air injection. We found excellent agreement between root native embolism and the levels of embolism measured using a centrifuge technique, and with air-seeding estimates from single-vessel injection. Estimates of cavitation resistance measured from centrifuge curves were biologically meaningful and were correlated with field minimum water potentials, vessel diameter (VD), maximum xylem-specific conductivity (Ksmax) and vessel length. Roots did not have unusually long vessels compared with stems; moreover, root vessel length was not correlated to VD or to the vessel length of stems. These results suggest that root cavitation resistance can be accurately and efficiently measured using a standard centrifuge method and that roots are highly vulnerable to cavitation. The role of root cavitation resistance in determining drought tolerance of woody species deserves further study, particularly in the context of climate change. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A unified electrostatic and cavitation model for first-principles molecular dynamics in solution

    OpenAIRE

    Scherlis, Damian A.; Fattebert, Jean-Luc; Gygi, Francois; Cococcioni, Matteo; Marzari, Nicola

    2005-01-01

    The electrostatic continuum solvent model developed by Fattebert and Gygi is combined with a first-principles formulation of the cavitation energy based on a natural quantum-mechanical definition for the surface of a solute. Despite its simplicity, the cavitation contribution calculated by this approach is found to be in remarkable agreement with that obtained by more complex algorithms relying on a large set of parameters. Our model allows for very efficient Car-Parrinello simulations of fin...

  17. Two-Color Laser High-Harmonic Generation in Cavitated Plasma Wakefields

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Carl; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2016-10-03

    A method is proposed for producing coherent x-rays via high-harmonic generation using a laser interacting with highly-stripped ions in cavitated plasma wakefields. Two laser pulses of different colors are employed: a long-wavelength pulse for cavitation and a short-wavelength pulse for harmonic generation. This method enables efficient laser harmonic generation in the sub-nm wavelength regime.

  18. Hydrodynamic cavitation as a strategy to enhance the efficiency of lignocellulosic biomass pretreatment

    DEFF Research Database (Denmark)

    Terán Hilares, Ruly; Ramos, Lucas; da Silva, Silvio Silvério

    2017-01-01

    Hydrodynamic cavitation (HC) is a process technology with potential for application in different areas including environmental, food processing, and biofuels production. Although HC is an undesirable phenomenon for hydraulic equipment, the net energy released during this process is enough...... to accelerate certain chemical reactions. The application of cavitation energy to enhance the efficiency of lignocellulosic biomass pretreatment is an interesting strategy proposed for integration in biorefineries for the production of bio-based products. Moreover, the use of an HC-assisted process...

  19. Ultrasound measurements of cavitation bubble radius for femtosecond laser-induced breakdown in water.

    Science.gov (United States)

    Aglyamov, Salavat R; Karpiouk, Andrei B; Bourgeois, Frederic; Ben-Yakar, Adela; Emelianov, Stanislav Y

    2008-06-15

    A recently developed ultrasound technique is evaluated by measuring the behavior of a cavitation bubble that is induced in water by a femtosecond laser pulse. The passive acoustic emission during optical breakdown is used to estimate the location of the cavitation bubble's origin. In turn, the position of the bubble wall is defined based on the active ultrasonic pulse-echo signal. The results suggest that the developed ultrasound technique can be used for quantitative measurements of femtosecond laser-induced microbubbles.

  20. Acute pulmonary embolism leading to cavitation and large pulmonary abscess: A rare complication of pulmonary infarction

    OpenAIRE

    Koroscil, Matthew T.; Hauser, Timothy R.

    2017-01-01

    Pulmonary infarction is an infrequent complication of pulmonary embolism due to the dual blood supply of the lung. Autopsy studies have reported cavitation to occur in only 4–5% of all pulmonary infarctions with an even smaller proportion of these cases becoming secondarily infected. Patients with infected cavitating pulmonary infarction classically present with fever, positive sputum culture, and leukocytosis days to weeks following acute pulmonary embolism. We describe a rare case of acute ...

  1. Two-color laser high-harmonic generation in cavitated plasma wakefields

    Science.gov (United States)

    Schroeder, C. B.; Benedetti, C.; Esarey, E.; Leemans, W. P.

    2017-03-01

    A method is proposed for producing coherent x-rays via high-harmonic generation using a laser interacting with highly-stripped ions in cavitated plasma wakefields. Two laser pulses of different colors are employed: a long-wavelength pulse for cavitation and a short-wavelength pulse for harmonic generation. This method enables efficient laser harmonic generation in the sub-nm wavelength regime.

  2. Shadowgraph, Schlieren and interferometry in a 2D cavitating channel flow

    OpenAIRE

    Mauger, Cyril; Méès, Loïc; Michard, Marc; Azouzi, Alexandre; Valette, Stéphane

    2012-01-01

    International audience; Cavitation plays an important role in fuel atomization mechanisms but the physics of cavitation and its impact on spray formation and injector efficiency are not well documented yet. Experimental investigations are required to support the development and the validation of numerical models and the design of tomorrow's injectors, in the context of pollutant and fuel consumption reduction. The complexity of modern injectors and the extreme conditions of injection do not f...

  3. Velocity measurements based on shadowgraph-like image correlations in a cavitating micro-channel flow

    OpenAIRE

    Mauger, Cyril; Méès, Loïc; Michard, Marc; Lance, Michel

    2014-01-01

    International audience; Cavitation is generally known for its drawbacks (noise, vibration, damage). However, it may play a beneficial role in the particular case of fuel injection, by enhancing atomization processes or reducing nozzle fouling. Studying cavitation in real injection configuration is therefore of great interest, yet tricky because of high pressure, high speed velocity, small dimensions and lack of optical access for instance. In this paper, the authors proposed a simplified and ...

  4. Influence of Prewhirl Regulation by Inlet Guide Vanes on Cavitation Performance of a Centrifugal Pump

    OpenAIRE

    Lei Tan; Baoshan Zhu; Shuliang Cao; Yuchuan Wang; Binbin Wang

    2014-01-01

    The influence of prewhirl regulation by inlet guide vanes (IGVs) on a centrifugal pump performance is investigated experimentally and numerically. The experimental results show that IGVs can obviously change the head and increase the efficiency of the tested centrifugal pump over a wide range of flow rates. Although the cavitation performance is degraded, the variation of the cavitation critical point is less than 0.5 m. Movement of the computed three-dimensional streamlines in suction pipe a...

  5. Clinical cavitation and radiographic lesion depth in proximal surfaces in an Indian population

    DEFF Research Database (Denmark)

    Sansare, Kaustubh; Raghav, Mamta; Sontakke, Subodeh

    2014-01-01

    Abstract Objectives. To assess the relationship between clinical cavitation and radiographic caries lesion depth in proximal surfaces of permanent posterior teeth in an Indian population. This study also assessed the clinical feasibility of applying 'western guidelines' to this population from...... the developing world. Materials and methods. Relationship between clinical cavitation and radiographic caries lesion depth in proximal surfaces in an Indian population was assessed. Proximal surfaces (n = 126) without restorations were examined on bitewing radiographs in patients with suspected caries and lesion...

  6. Penetration of sub-micron particles into dentinal tubules using ultrasonic cavitation.

    Science.gov (United States)

    Vyas, N; Sammons, R L; Pikramenou, Z; Palin, W M; Dehghani, H; Walmsley, A D

    2017-01-01

    Functionalised silica sub-micron particles are being investigated as a method of delivering antimicrobials and remineralisation agents into dentinal tubules. However, their methods of application are not optimised, resulting in shallow penetration and aggregation. The aim of this study is to investigate the impact of cavitation occurring around ultrasonic scalers for enhancing particle penetration into dentinal tubules. Dentine slices were prepared from premolar teeth. Silica sub-micron particles were prepared in water or acetone. Cavitation from an ultrasonic scaler (Satelec P5 Newtron, Acteon, France) was applied to dentine slices immersed inside the sub-micron particle solutions. Samples were imaged with scanning electron microscopy (SEM) to assess tubule occlusion and particle penetration. Qualitative observations of SEM images showed some tubule occlusion. The particles could penetrate inside the tubules up to 60μm when there was no cavitation and up to ∼180μm when there was cavitation. The cavitation bubbles produced from an ultrasonic scaler may be used to deliver sub-micron particles into dentine. This method has the potential to deliver such particles deeper into the dentinal tubules. Cavitation from a clinical ultrasonic scaler may enhance penetration of sub-micron particles into dentinal tubules. This can aid in the development of novel methods for delivering therapeutic clinical materials for hypersensitivity relief and treatment of dentinal caries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Evaluation of inertial cavitation activity in tissue through measurement of oxidative stress.

    Science.gov (United States)

    Prieur, Fabrice; Pialoux, Vincent; Mestas, Jean-Louis; Mury, Pauline; Skinner, Sarah; Lafon, Cyril

    2015-09-01

    Ultrasound cavitation is an essential mechanism involved in the therapeutic local enhancement of drug delivery by ultrasound for cancer treatment. Inertial cavitation also triggers chemical reactions that generate free radicals and subsequent oxidative stress in the tissue. The aim of this study was to measure the oxidative stress induced by inertial cavitation in ex vivo tissue and to test the association between the exposure conditions and the oxidative stress. A confocal ultrasound setup was used to sonicate and create inertial cavitation in freshly excised adipose pig tissue. The ex vivo tissue samples were then processed to measure the quantity of malondialdehyde (MDA), an end-product of polyunsaturated free fatty acid oxidation. The creation of hydroxyterephthalic acid (HTA) from the reaction of terephthalic acid (TA) with free radicals in water was also quantified in vitro. Samples were sonicated for different durations using various amplitudes for the applied pressure. The results showed a minimum 2-fold increase in the amount of detected MDA in the sonicated tissue samples compared to baseline clearly suggesting the generation of free radicals by inertial cavitation. The method exhibited a moderate dependence of MDA generated upon the duration of exposure (R(2)=057,p0.95,pcavitation. In large enough sample populations, the cavitation activity is linked to the exposure conditions of the sonication. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Post Hoc Analysis of Passive Cavitation Imaging for Classification of Histotripsy-Induced Liquefaction in Vitro.

    Science.gov (United States)

    Bader, Kenneth B; Haworth, Kevin J; Maxwell, Adam D; Holland, Christy K

    2018-01-01

    Histotripsy utilizes focused ultrasound to generate bubble clouds for transcutaneous tissue liquefaction. Bubble activity maps are under development to provide image guidance and monitor treatment progress. The aim of this paper was to investigate the feasibility of using plane wave B-mode and passive cavitation images to be used as binary classifiers of histotripsy-induced liquefaction. Prostate tissue phantoms were exposed to histotripsy pulses over a range of pulse durations (5- ) and peak negative pressures (12-23 MPa). Acoustic emissions were recorded during the insonation and beamformed to form passive cavitation images. Plane wave B-mode images were acquired following the insonation to detect the hyperechoic bubble cloud. Phantom samples were sectioned and stained to delineate the liquefaction zone. Correlation between passive cavitation and plane wave B-mode images and the liquefaction zone was assessed using receiver operating characteristic (ROC) curve analysis. Liquefaction of the phantom was observed for all the insonation conditions. The area under the ROC (0.94 versus 0.82), accuracy (0.90 versus 0.83), and sensitivity (0.81 versus 0.49) was greater for passive cavitation images relative to B-mode images ( ) along the azimuth of the liquefaction zone. The specificity was greater than 0.9 for both imaging modalities. These results demonstrate a stronger correlation between histotripsy-induced liquefaction and passive cavitation imaging compared with the plane wave B-mode imaging, albeit with limited passive cavitation image range resolution.

  9. Swirling cavitation improves the emulsifying properties of commercial soy protein isolate.

    Science.gov (United States)

    Yang, Feng; Liu, Xue; Ren, Xian'e; Huang, Yongchun; Huang, Chengdu; Zhang, Kunming

    2018-04-01

    Since emulsifying properties are important functional properties of soy protein, many physical, chemical, and enzymatic methods have been applied to treat soy protein to improve emulsifying properties. In this study, we investigated the effects of swirling cavitation at different pressures and for different times on emulsifying and physicochemical properties of soy protein isolate (SPI). The SPI treated with swirling cavitation showed a significant decrease in particle size and increase in solubility. Emulsions formed from treated SPI had higher emulsifying activity and emulsifying stability indexes, smaller oil droplet sizes, lower flocculation indexes, higher adsorbed proteins, lower interfacial protein concentrations, and lower creaming indexes than those formed from untreated SPI, indicating that swirling cavitation improved the emulsifying properties of the SPI. Furthermore, swirling cavitation treatment significantly enhanced the surface hydrophobicity, altered the disulfide bond and exposed sulfhydryl group contents of the SPI. The secondary structure of the SPI was also influenced by swirling cavitation, with an increase in β-sheet content and a decrease in α-helix, β-turn, and random coil contents. In addition, several significant correlations between physicochemical and emulsifying properties were revealed by Pearson correlation analysis, suggesting that the physicochemical changes observed in treated SPI, including the decreased particle size, increased solubility and surface hydrophobicity, and enhanced β-sheet formation, may explain the improved emulsifying properties of the isolate. Thus, our findings implied that swirling cavitation treatment may be an effective technique to improve the emulsifying properties of SPI. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Cavitation erosion and corrosion behavior of copper-manganese-aluminum alloy weldment

    Energy Technology Data Exchange (ETDEWEB)

    Li, X.Y.; Yan, Y.G.; Ma, L.; Xu, Z.M.; Li, J.G

    2004-09-25

    Welding is a common method for repairing damaged ship propellers, especially by cavitation erosion. Reports on cavitation erosion and corrosion behavior of copper-manganese-aluminum (CMA) alloy weldment are sparse. In this paper, CMA weldment was prepared by tungsten inert gas welding (TIG), and its cavitation erosion behavior and corrosion behavior in 3.5% NaCl aqueous solution were studied by magnetostrictive vibratory device for cavitation erosion and electrochemical device, respectively. Results show that the weld zone (WZ) of the weldment exhibits better cavitation erosion and corrosion resistance than the heat-affected zone (HAZ) and the base metal. The cumulative mass loss of the WZ is only 1/4 that of the base metal. SEM analysis of eroded specimens reveals that the base metal is attacked most severely; the HAZ less and the WZ least. The microcracks causing cavitation damage initiate at the phase boundaries. Among the three zones of the weldment, the WZ is the noblest, its corrosion potential is -266 mV, while the HAZ, -284 mV, and the base metal, -279 mV, in about 60 h exposure to 3.5% NaCl aqueous solution. And its corrosion current density is the lowest, about 0.035 A m{sup -2}, while the HAZ, 0.078 A m{sup -2}, and the base metal, {+-}0.79 A m{sup -2}.

  11. A review and assessment of hydrodynamic cavitation as a technology for the future.

    Science.gov (United States)

    Gogate, Parag R; Pandit, Aniruddha B

    2005-01-01

    In the present work, the current status of the hydrodynamic cavitation reactors has been reviewed discussing the bubble dynamics analysis, optimum design considerations, design correlations for cavitational intensity (in terms of collapse pressure)/cavitational yield and different successful chemical synthesis applications clearly illustrating the utility of these types of reactors. The theoretical discussion based on the modeling of the bubble dynamics equations aims at understanding the design information related to the dependency of the cavitational intensity on the operating parameters and recommendations have been made for the choice of the optimized conditions of operating parameters. The design information based on the theoretical analysis has also been supported with some experimental illustrations concentrating on the chemical synthesis applications. Assessment of the hydrodynamic cavitation reactors and comparison with the sonochemical reactors has been done by citing the different industrially important reactions (oxidation of toluene, o-xylene, m-xylene, p-xylene, mesitylene, o-nitrotoluene, p-nitrotoluene, m-nitrotoluene, o-chlorotoluene and p-chlorotoulene, and trans-esterification reaction i.e., synthesis of bio-diesel). Some recommendations have also been made for the future work to be carried out as well as the choice of the operating conditions for realizing the dream of industrial scale applications of the cavitational reactors.

  12. Application of modified k-ω model to predicting cavitating flow in centrifugal pump

    Directory of Open Access Journals (Sweden)

    Hou-lin LIU

    2013-07-01

    Full Text Available Considering the compressibility of the cavity in the cavitating flow, this paper presents a modified k-ω model for predicting the cavitating flow in a centrifugal pump, in which the modified k-ω model and Schnerr-Sauer cavitation model were combined with ANSYS CFX. To evaluate the modified and standard k-ω models, numerical simulations were performed with these two models, respectively, and the calculation results were compared with the experimental data. Numerical simulations were executed with three different values of the flow coefficient, and the simulation results of the modified k-ω model showed agreement with most of the experimental data. The cavitating flow in the centrifugal pump obtained by the modified k-ω model at the design flow coefficient of 0.102, was analyzed. When the cavitation number decreases, the cavity initially generates on the suction side of the blade near the leading edge and then expands to the outlet of the impeller, and the decrease of the total pressure coefficient mainly occurs upstream of the impeller passage, while the downstream remains almost unaffected by the development of cavitation.

  13. A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power

    Energy Technology Data Exchange (ETDEWEB)

    Hodnett, M; Zeqiri, B [National Physical Laboratory, Queens Road, Teddington, Middlesex, TW11 0LW (United Kingdom)

    2004-01-01

    Acoustic cavitation occurring in the water path between a transducer and the target of a radiation force balance can provide a significant source of error during measurements of ultrasonic power. These problems can be particularly acute at physiotherapy levels (>1 W), and low frequencies ({<=} 1 MHz). The cavitating bubbles can absorb and scatter incident ultrasound, leading to an underestimate in the measured power. For these reasons, International Specification standards demand the use of degassed water. This imposes requirements that may actually be difficult to meet, for example, in the case of hospitals. Also, initially degassed water will rapidly re-gas, increasing the likelihood of cavitation occurring. For these reasons, NPL has developed a device that monitors acoustic emissions generated by bubble activity, for detecting the onset of cavitation during power measurements. A commercially available needle hydrophone is used to detect these emissions. The acoustic signals are then monitored using a Cavitation Detector (CD) unit, comprising an analogue electrical filter that may be tuned to detect frequency components generated by cavitating bubbles, and which provides an indication of when the measured level exceeds a pre-defined threshold. This paper describes studies to establish a suitable detection scheme, the principles of operation of the CD unit, and the performance tests carried out with a range of propagation media.

  14. Cavitation of a Propeller and Influence of an Wake Equalizing Duct

    Directory of Open Access Journals (Sweden)

    George Martinas

    2015-06-01

    Full Text Available The wake equalizing duct (WED is one of the most commonly used energy saving devices for improving the propulsion performance of a ship; and reducing the propeller-excited vibrations and viscous resistance forces. During the last three decades considerable research and development activities have taken into place within this context. Most of these devices are used to improve propulsive efficiency, but some of them aims to improve other performance characteristics, such as cavitations, vibration, noise, maneuverability, etc. Marine propellers are the most common propulsion systems; nevertheless, it is possible to improve its propulsive performance using additional auxiliary propulsor devices (unconventional propulsors. Two versions of an existing ship in normal version and fitted with WED device were analyzed in order to demonstrate the influence on the WED device on the propeller cavitations . It was determined that the values for the pressure coefficient is 1.98 for without WED situation and 2.029 for WED situation. The difference is not so significant that, the conclusion is that WED device did not have influence over the cavitations of the propeller. Either optimization of dimension and form of WED did not help in reducing negative effects of cavitations. Not being a study in this paperwork, to decrease the cavitations we have other choices including a sound design of the propeller biased to improve the propeller behavior in cavitations. WED is clearly not a choice.

  15. The use of Rz roughness parameter for evaluation of materials behavior to cavitation erosion

    Science.gov (United States)

    Bordeasu, I.; Popoviciu, M. O.; Ghera, C.; Micu, L. M.; Pirvulescu, L. D.; Bena, T.

    2018-01-01

    It is well known that the cavitation eroded surfaces have a porous appearance with a pronounced roughness. The cause is the pitting resulted from the impact with the micro jets as well as the shock waves both determined by the implosion of cavitation bubbles. The height and the shape of roughness is undoubtedly an expression of the resistance of the surface to the cavitation stresses. The paper put into evidence the possibility of using the roughness parameter Rz for estimating the material resistance to cavitation phenomena. For this purpose, the mean depth erosion penetration (MDE-parameter, recommended by the ASTM G32-2010 Standard) was compared with the roughness of three different materials (an annealed bronze, the same bronze subjected to quenching and an annealed alloyed steel), both measured at four cavitation erosion exposure (30, 75, 120 and 165 minutes). The roughness measurements were made in 18 different zones, disposed after two perpendicular diameters, along a measuring lengths of 4 mm. The results confirm the possibility of using the parameter Rz for estimating the cavitation erosion resistance of a material. The differences between the measured values of Rz and those of the characteristic parameter MDE are of the same order of magnitude as those obtained for MDE determination, using more samples of the same material.

  16. Numerical investigation on cavitation flow of hydrofoil and its flow noise with emphasis on turbulence models

    Science.gov (United States)

    Kim, Sanghyeon; Cheong, Cheolung; Park, Warn-Gyu

    2017-06-01

    In this study, cavitation flow of hydrofoils is numerically investigated to characterize the effects of turbulence models on cavitation-flow patterns and the corresponding radiated sound waves. The two distinct flow conditions are considered by varying the mean flow velocity and angle of attack, which are categorized under the experimentally observed unstable or stable cavitation flows. To consider the phase interchanges between the vapor and the liquid, the flow fields around the hydrofoil are analyzed by solving the unsteady compressible Reynolds-averaged Navier-Stokes equations coupled with a mass-transfer model, also referred to as the cavitation model. In the numerical solver, a preconditioning algorithm with dual-time stepping techniques is employed in generalized curvilinear coordinates. The following three types of turbulence models are employed: the laminar-flow model, standard k - ɛ turbulent model, and filter-based model. Hydro-acoustic field formed by the cavitation flow of the hydrofoil is predicted by applying the Ffowcs Williams and Hawkings equation to the predicted flow field. From the predicted results, the effects of the turbulences on the cavitation flow pattern and radiated flow noise are quantitatively assessed in terms of the void fraction, sound-pressure-propagation directivities, and spectrum.

  17. Numerical investigation on cavitation flow of hydrofoil and its flow noise with emphasis on turbulence models

    Directory of Open Access Journals (Sweden)

    Sanghyeon Kim

    2017-06-01

    Full Text Available In this study, cavitation flow of hydrofoils is numerically investigated to characterize the effects of turbulence models on cavitation-flow patterns and the corresponding radiated sound waves. The two distinct flow conditions are considered by varying the mean flow velocity and angle of attack, which are categorized under the experimentally observed unstable or stable cavitation flows. To consider the phase interchanges between the vapor and the liquid, the flow fields around the hydrofoil are analyzed by solving the unsteady compressible Reynolds-averaged Navier–Stokes equations coupled with a mass-transfer model, also referred to as the cavitation model. In the numerical solver, a preconditioning algorithm with dual-time stepping techniques is employed in generalized curvilinear coordinates. The following three types of turbulence models are employed: the laminar-flow model, standard k − ε turbulent model, and filter-based model. Hydro-acoustic field formed by the cavitation flow of the hydrofoil is predicted by applying the Ffowcs Williams and Hawkings equation to the predicted flow field. From the predicted results, the effects of the turbulences on the cavitation flow pattern and radiated flow noise are quantitatively assessed in terms of the void fraction, sound-pressure-propagation directivities, and spectrum.

  18. Spectral Analysis of Pressure, Noise and Vibration Velocity Measurement in Cavitation

    Science.gov (United States)

    Jablonská, Jana; Mahdal, Miroslav; Kozubková, Milada

    2017-12-01

    The article deals with experimental investigation of water cavitation in the convergent-divergent nozzle of rectangular cross-section. In practice, a quick and simple determination of cavitation is essential, especially if it is basic cavitation or cavitation generated additionally by the air being sucked. Air influences the formation, development and size of the cavity area in hydraulic elements. Removal or reduction of the cavity area is possible by structural changes of the element. In case of the cavitation with the suction air, it is necessary to find the source of the air and seal it. The pressure gradient, the flow, the oxygen content in the tank, and hence the air dissolved in the water, the air flow rate, the noise intensity and the vibration velocity on the nozzle wall were measured on laboratory equipment. From the selected measurements the frequency spectrum of the variation of the water flow of the cavity with cavitation without air saturation and with air saturation was compared and evaluated.

  19. Numerical Modeling of Cavitating Venturi: A Flow Control Element of Propulsion System

    Science.gov (United States)

    Majumdar, Alok; Saxon, Jeff (Technical Monitor)

    2002-01-01

    In a propulsion system, the propellant flow and mixture ratio could be controlled either by variable area flow control valves or by passive flow control elements such as cavitating venturies. Cavitating venturies maintain constant propellant flowrate for fixed inlet conditions (pressure and temperature) and wide range of outlet pressures, thereby maintain constant, engine thrust and mixture ratio. The flowrate through the venturi reaches a constant value and becomes independent of outlet pressure when the pressure at throat becomes equal to vapor pressure. In order to develop a numerical model of propulsion system, it is necessary to model cavitating venturies in propellant feed systems. This paper presents a finite volume model of flow network of a cavitating venturi. The venturi was discretized into a number of control volumes and mass, momentum and energy conservation equations in each control volume are simultaneously solved to calculate one-dimensional pressure, density, and flowrate and temperature distribution. The numerical model predicts cavitations at the throat when outlet pressure was gradually reduced. Once cavitation starts, with further reduction of downstream pressure, no change in flowrate is found. The numerical predictions have been compared with test data and empirical equation based on Bernoulli's equation.

  20. Cavitation structures formed during the rebound of a sphere from a wetted surface

    KAUST Repository

    Marston, Jeremy

    2010-09-28

    We use high-speed imaging to observe the dynamics of cavitation, caused by the impact and subsequent rebound of a sphere from a solid surface covered with a thin layer of highly viscous liquid. We note marked qualitative differences between the cavitation structures with increase in viscosity, as well as between Newtonian and non-Newtonian liquids. The patterns observed are quite unexpected and intricate, appearing in concentric ring formations around the site of impact. In all cases, we identify a distinct radius from which the primary bubbles emanate. This radius is modelled with a modified form of Hertz contact theory. Within this radius, we show that some fine cavitation structure may exist or that it may be one large cavitation bubble. For the non-Newtonian fluids, we observe foam-like structures extending radially with diminishing bubble sizes with increase in radial position. Whereas for the Newtonian fluids, the opposite trend is observed with increasing bubble size for increasing radial position. Finally, we compare our experimental observations of cavitation to the maximum tension criterion proposed by Joseph (J Fluid Mech 366:367-378, 1998) showing that this provides the lower limit for the onset of cavitation in our experiments. © 2010 Springer-Verlag.

  1. Mitigation of tip vortex cavitation by means of air injection on a Kaplan turbine scale model

    Science.gov (United States)

    Rivetti, A.; Angulo, M.; Lucino, C.; Liscia, S.

    2014-03-01

    Kaplan turbines operating at full-load conditions may undergo excessive vibration, noise and cavitation. In such cases, damage by erosion associated to tip vortex cavitation can be observed at the discharge ring. This phenomenon involves design features such as (1) overhang of guide vanes; (2) blade profile; (3) gap increasing size with blade opening; (4) suction head; (5) operation point; and (6) discharge ring stiffness, among others. Tip vortex cavitation may cause erosion at the discharge ring and draft tube inlet following a wavy pattern, in which the number of vanes can be clearly identified. Injection of pressurized air above the runner blade centerline was tested as a mean to mitigate discharge ring cavitation damage on a scale model. Air entrance was observed by means of a high-speed camera in order to track the air trajectory toward its mergence with the tip vortex cavitation core. Post-processing of acceleration signals shows that the level of vibration and the RSI frequency amplitude decrease proportionally with air flow rate injected. These findings reveal the potential mitigating effect of air injection in preventing cavitation damage and will be useful in further tests to be performed on prototype, aiming at determining the optimum air flow rate, size and distribution of the injectors.

  2. Degradation of diclofenac sodium using combined processes based on hydrodynamic cavitation and heterogeneous photocatalysis.

    Science.gov (United States)

    Bagal, Manisha V; Gogate, Parag R

    2014-05-01

    Diclofenac sodium, a widely detected pharmaceutical drug in wastewater samples, has been selected as a model pollutant for degradation using novel combined approach of hydrodynamic cavitation and heterogeneous photocatalysis. A slit venturi has been used as cavitating device in the hydrodynamic cavitation reactor. The effect of various operating parameters such as inlet fluid pressure (2-4 bar) and initial pH of the solution (4-7.5) on the extent of degradation have been studied. The maximum extent of degradation of diclofenac sodium was obtained at inlet fluid pressure of 3 bar and initial pH as 4 using hydrodynamic cavitation alone. The loadings of TiO2 and H2O2 have been optimised to maximise the extent of degradation of diclofenac sodium. Kinetic study revealed that the degradation of diclofenac sodium fitted first order kinetics over the selected range of operating protocols. It has been observed that combination of hydrodynamic cavitation with UV, UV/TiO2 and UV/TiO2/H2O2 results in enhanced extents of degradation as compared to the individual schemes. The maximum extent of degradation as 95% with 76% reduction in TOC has been observed using hydrodynamic cavitation in conjunction with UV/TiO2/H2O2 under the optimised operating conditions. The diclofenac sodium degradation byproducts have been identified using LC/MS analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. RANS computations for identification of 1-D cavitation model parameters: application to full load cavitation vortex rope

    Science.gov (United States)

    Alligné, S.; Decaix, J.; Müller, A.; Nicolet, C.; Avellan, F.; Münch, C.

    2017-04-01

    Due to the massive penetration of alternative renewable energies, hydropower is a key energy conversion technology for stabilizing the electrical power network by using hydraulic machines at off design operating conditions. At full load, the axisymmetric cavitation vortex rope developing in Francis turbines acts as an internal source of energy, leading to an instability commonly referred to as self-excited surge. 1-D models are developed to predict this phenomenon and to define the range of safe operating points for a hydropower plant. These models require a calibration of several parameters. The present work aims at identifying these parameters by using CFD results as objective functions for an optimization process. A 2-D Venturi and 3-D Francis turbine are considered.

  4. Visualization of the cavitation bubbles produced by a clinical shock wave field using a micropulse LED light

    Science.gov (United States)

    Kang, Gwansuk; Huh, Jung Sik; Choi, Min Joo

    2017-07-01

    Extracorporeal shock wave therapy employs intense shock waves that produce cavitation bubbles understood to play an important role in therapeutic effects. This study considers shock-wave-induced cavitation bubbles, expected to be closely associated with treated therapeutic regions. A simple optical method was devised to visualize the cavitation bubbles under micropulse LED light illumination and to capture an afterimage of the bubbles for their entire lifetime from formation to collapse. The optical images of the cavitation bubbles produced by a clinical shock wave therapeutic device were shown to preserve the characteristics of the focusing shock wave field. The similarity of the characteristics may enable the cavitation cloud image to provide the intensity and location of shock wave irradiation for the clinical quality assurance of therapeutic devices. Further research that includes the dynamic effects in the static images of cavitation bubbles is suggested.

  5. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies

    Science.gov (United States)

    Arvanitis, Costas D.; McDannold, Nathan

    2013-01-01

    Purpose: Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. Methods: The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30–110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. Results: When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was −3.4 ± 2.1 mm and −0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small

  6. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

    Science.gov (United States)

    Arvanitis, Costas D; McDannold, Nathan

    2013-11-01

    Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30-110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was -3.4 ± 2.1 mm and -0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM

  7. Canakinumab (ACZ885, a fully human IgG1 anti-IL-1β mAb) induces sustained remission in pediatric patients with cryopyrin-associated periodic syndrome (CAPS).

    Science.gov (United States)

    Kuemmerle-Deschner, Jasmin B; Ramos, Eduardo; Blank, Norbert; Roesler, Joachim; Felix, Sandra D; Jung, Thomas; Stricker, Kirstin; Chakraborty, Abhijit; Tannenbaum, Stacey; Wright, Andrew M; Rordorf, Christiane

    2011-02-28

    Cryopyrin-associated periodic syndrome (CAPS) represents a spectrum of three auto-inflammatory syndromes, familial cold auto-inflammatory syndrome (FCAS), Muckle-Wells syndrome (MWS), and neonatal-onset multisystem inflammatory disease/chronic infantile neurological cutaneous and articular syndrome (NOMID/CINCA) with etiology linked to mutations in the NLRP3 gene resulting in elevated interleukin-1β (IL-1β) release. CAPS is a rare hereditary auto-inflammatory disease, which may start early in childhood and requires a life-long treatment. Canakinumab, a fully human anti-IL-1β antibody, produces sustained selective inhibition of IL-1β. This study was conducted to assess the efficacy, safety, and pharmacokinetics of canakinumab in the treatment of pediatric CAPS patients. Seven pediatric patients (five children and two adolescents) with CAPS were enrolled in a phase II, open-label study of canakinumab in patients with CAPS. Canakinumab was administered at a dose of 2 mg/kg subcutaneously (s.c.) (for patients with body weight ≤ 40 kg) or 150 mg s.c. (for patients with body weight > 40 kg) with re-dosing upon each relapse. The primary efficacy variable was time to relapse following achievement of a complete response (defined as a global assessment of no or minimal disease activity and no or minimal rash and values for serum C-reactive protein (CRP) and/or serum amyloid A (SAA) within the normal range, CAPS. ClinicalTrials.gov: NCT00487708.

  8. The role of positive and negative pressure on cavitation nucleation in nanodroplet-mediated histotripsy

    Science.gov (United States)

    Vlaisavljevich, Eli; Aydin, Omer; Lin, Kuang-Wei; Yuksel Durmaz, Yasemin; Fowlkes, Brian; ElSayed, Mohamed; Xu, Zhen

    2016-01-01

    Nanodroplet-mediated histotripsy (NMH) is an ultrasound ablation technique combining histotripsy with acoustically sensitive perfluorocarbon (PFC) nanodroplets that can be selectively delivered to tumor cells for targeted tumor ablation. NMH takes advantage of the significantly reduced cavitation threshold of the nanodroplets, allowing for cavitation to be selectively generated only in regions containing nanodroplets. Understanding the physical mechanisms underlying the nanodroplet cavitation process is essential to the development of NMH. In this study, we hypothesize that cavitation nucleation is caused by the negative pressure (p-) exposed to the PFC, and the NMH cavitation threshold is therefore determined by the incident p-  of the single-cycle pulses commonly used in NMH. This paper reports the first study that separately investigates the effects of negative and positive pressure on the NMH cavitation threshold using near half-cycle ultrasound pulses with dominant negative (negative-polarity pulses) or positive (positive-polarity pulses) pressure phases. Tissue phantoms containing perfluorohexane (PFH) nanodroplets were exposed to negative-polarity and positive-polarity pulses generated by a frequency compounding transducer recently developed in our lab, and the probability of generating cavitation was measured as a function of peak negative (p-) and peak positive (p+) pressure. The results showed close agreement in the p-  cavitation threshold for PFH phantoms exposed to negative-polarity (11.4  ±  0.1 MPa) and positive-polarity (11.7  ±  0.2 MPa) pulses. The p+ at the cavitation threshold, in contrast, was measured to be significantly different for the negative-polarity (4.0  ±  0.1 MPa) and positive-polarity (42.6  ±  0.2 MPa) pulses. In the final part of this study, the experimental results were compared to the cavitation threshold predicted by classical nucleation theory (CNT), with results showing

  9. Numerical prediction of cavitating flow around a hydrofoil using pans and improved shear stress transport k-omega model

    Directory of Open Access Journals (Sweden)

    Zhang De-Sheng

    2015-01-01

    Full Text Available The prediction accuracies of partially-averaged Navier-Stokes model and improved shear stress transport k-ω turbulence model for simulating the unsteady cavitating flow around the hydrofoil were discussed in this paper. Numerical results show that the two turbulence models can effectively reproduce the cavitation evolution process. The numerical prediction for the cycle time of cavitation inception, development, detachment, and collapse agrees well with the experimental data. It is found that the vortex pair induced by the interaction between the re-entrant jet and mainstream is responsible for the instability of the cavitation shedding flow.

  10. Passive cavitation detection during pulsed HIFU exposures of ex vivo tissues and in vivo mouse pancreatic tumors.

    Science.gov (United States)

    Li, Tong; Chen, Hong; Khokhlova, Tatiana; Wang, Yak-Nam; Kreider, Wayne; He, Xuemei; Hwang, Joo Ha

    2014-07-01

    Pulsed high-intensity focused ultrasound (pHIFU) has been shown to enhance vascular permeability, disrupt tumor barriers and enhance drug penetration into tumor tissue through acoustic cavitation. Monitoring of cavitation activity during pHIFU treatments and knowing the ultrasound pressure levels sufficient to reliably induce cavitation in a given tissue are therefore very important. Here, three metrics of cavitation activity induced by pHIFU and evaluated by confocal passive cavitation detection were introduced: cavitation probability, cavitation persistence and the level of the broadband acoustic emissions. These metrics were used to characterize cavitation activity in several ex vivo tissue types (bovine tongue and liver and porcine adipose tissue and kidney) and gel phantoms (polyacrylamide and agarose) at varying peak-rare factional focal pressures (1-12 MPa) during the following pHIFU protocol: frequency 1.1 MHz, pulse duration 1 ms and pulse repetition frequency 1 Hz. To evaluate the relevance of the measurements in ex vivo tissue, cavitation metrics were also investigated and compared in the ex vivo and in vivo murine pancreatic tumors that develop spontaneously in transgenic KrasLSL.G12 D/+; p53 R172 H/+; PdxCretg/+ (KPC) mice and closely re-capitulate human disease in their morphology. The cavitation threshold, defined at 50% cavitation probability, was found to vary broadly among the investigated tissues (within 2.5-10 MPa), depending mostly on the water-lipid ratio that characterizes the tissue composition. Cavitation persistence and the intensity of broadband emissions depended both on tissue structure and lipid concentration. Both the cavitation threshold and broadband noise emission level were similar between ex vivo and in vivo pancreatic tumor tissue. The largest difference between in vivo and ex vivo settings was found in the pattern of cavitation occurrence throughout pHIFU exposure: it was sporadic in vivo, but it decreased rapidly and stopped

  11. Extracting a Whisper from the DIN: A Bayesian-Inductive Approach to Learning an Anticipatory Model of Cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.

    1999-11-07

    For several reasons, Bayesian parameter estimation is superior to other methods for inductively learning a model for an anticipatory system. Since it exploits prior knowledge, the analysis begins from a more advantageous starting point than other methods. Also, since "nuisance parameters" can be removed from the Bayesian analysis, the description of the model need not be as complete as is necessary for such methods as matched filtering. In the limit of perfectly random noise and a perfect description of the model, the signal-to-noise ratio improves as the square root of the number of samples in the data. Even with the imperfections of real-world data, Bayesian methods approach this ideal limit of performance more closely than other methods. These capabilities provide a strategy for addressing a major unsolved problem in pump operation: the identification of precursors of cavitation. Cavitation causes immediate degradation of pump performance and ultimate destruction of the pump. However, the most efficient point to operate a pump is just below the threshold of cavitation. It might be hoped that a straightforward method to minimize pump cavitation damage would be to simply adjust the operating point until the inception of cavitation is detected and then to slightly readjust the operating point to let the cavitation vanish. However, due to the continuously evolving state of the fluid moving through the pump, the threshold of cavitation tends to wander. What is needed is to anticipate cavitation, and this requires the detection and identification of precursor features that occur just before cavitation starts.

  12. Controlled single bubble cavitation collapse results in jet-induced injury in brain tissue.

    Science.gov (United States)

    Canchi, Saranya; Kelly, Karen; Hong, Yu; King, Michael A; Subhash, Ghatu; Sarntinoranont, Malisa

    2017-10-01

    Multiscale damage due to cavitation is considered as a potential mechanism of traumatic brain injury (TBI) associated with explosion. In this study, we employed a TBI relevant hippocampal ex vivo slice model to induce bubble cavitation. Placement of single reproducible seed bubbles allowed control of size, number, and tissue location to visualize and measure deformation parameters. Maximum strain value was measured at 45 µs after bubble collapse, presented with a distinct contour and coincided temporally and spatially with the liquid jet. Composite injury maps combined this maximum strain value with maximum measured bubble size and location along with histological injury patterns. This facilitated the correlation of bubble location and subsequent jet direction to the corresponding regions of high strain which overlapped with regions of observed injury. A dynamic threshold strain range for tearing of cerebral cortex was estimated to be between 0.5 and 0.6. For a seed bubble placed underneath the hippocampus, cavitation induced damage was observed in hippocampus (local), proximal cerebral cortex (marginal) and the midbrain/forebrain (remote) upon histological evaluation. Within this test model, zone of cavitation injury was greater than the maximum radius of the bubble. Separation of apposed structures, tissue tearing, and disruption of cellular layers defined early injury patterns that were not detected in the blast-exposed half of the brain slice. Ultrastructural pathology of the neurons exposed to cavitation was characterized by disintegration of plasma membrane along with loss of cellular content. The developed test system provided a controlled experimental platform to study cavitation induced high strain deformations on brain tissue slice. The goal of the future studies will be to lower underpressure magnitude and cavitation bubble size for more sensitive evaluation of injury. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Prkci is required for a non-autonomous signal that coordinates cell polarity during cavitation.

    Science.gov (United States)

    Mah, In Kyoung; Soloff, Rachel; Izuhara, Audrey K; Lakeland, Daniel L; Wang, Charles; Mariani, Francesca V

    2016-08-01

    Polarized epithelia define boundaries, spaces, and cavities within organisms. Cavitation, a process by which multicellular hollow balls or tubes are produced, is typically associated with the formation of organized epithelia. In order for these epithelial layers to form, cells must ultimately establish a distinct apical-basal polarity. Atypical PKCs have been proposed to be required for apical-basal polarity in diverse species. Here we show that while cells null for the Prkci isozyme exhibit some polarity characteristics, they fail to properly segregate apical-basal proteins, form a coordinated ectodermal epithelium, or participate in normal cavitation. A failure to cavitate could be due to an overgrowth of interior cells or to an inability of interior cells to die. Null cells however, do not have a marked change in proliferation rate and are still capable of undergoing cell death, suggesting that alterations in these processes are not the predominant cause of the failed cavitation. Overexpression of BMP4 or EZRIN can partially rescue the phenotype possibly by promoting cell death, polarity, and differentiation. However, neither is sufficient to provide the required cues to generate a polarized epithelium and fully rescue cavitation. Interestingly, when wildtype and Prkci(-/-) ES cells are mixed together, a polarized ectodermal epithelium forms and cavitation is rescued, likely due to the ability of wildtype cells to produce non-autonomous polarity cues. We conclude that Prkci is not required for cells to respond to these cues, though it is required to produce them. Together these findings indicate that environmental cues can facilitate the formation of polarized epithelia and that cavitation requires the proper coordination of multiple basic cellular processes including proliferation, differentiation, cell death, and apical-basal polarization. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Sustainable agriculture

    National Research Council Canada - National Science Library

    Lichtfouse, Eric

    2009-01-01

    ... : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 9 Part I CLIMATE CHANGE Soils and Sustainable Agriculture: A Review : : : : : : : : : : : : : : : : : : : : : : : : : : Rattan Lal 15 Soils and Food Sufficiency...

  15. Tumoral cavitation in patients with non-small-cell lung cancer treated with antiangiogenic therapy using bevacizumab

    Science.gov (United States)

    Nishino, Mizuki; Cryer, Sarah K.; Okajima, Yuka; Sholl, Lynette M.; Hatabu, Hiroto; Rabin, Michael S.; Jackman, David M.; Johnson, Bruce E.

    2012-01-01

    Abstract Rationale and objectives: To investigate the frequency and radiographic patterns of tumoral cavitation in patients with non-small cell lung cancer (NSCLC) treated with bevacizumab, and correlate the imaging findings with the pathology, clinical characteristics and outcome. Materials and methods: Seventy-two patients with NSCLC treated with bevacizumab therapy were identified retrospectively. Baseline and follow-up chest computed tomography scan were reviewed to identify tumoral cavitation and subsequent filling in of cavitation. Radiographic cavitation patterns were classified into 3 groups. The clinical and outcome data were correlated with cavity formation and patterns. Results: Out of 72 patients, 14 patients developed cavitation after the initiation of bevacizumab therapy (19%; median time to event, 1.5 months; range 1.0–24.8 months). Three radiographic patterns of tumoral cavitation were noted: (1) development of cavity within the dominant lung tumor (n = 8); (2) development of non-dominant cavitary nodules (n = 3); and (3) development of non-dominant cavitary nodules with adjacent interstitial abnormalities (n = 3). Eleven patients (79%) demonstrated subsequent filling in of cavitation (the time from the cavity formation to filling in; median 3.7 months; range 1.9–22.7 months). No significant difference was observed in the clinical characteristics, including smoking history, or in the survival between patients who developed cavitation and those who did not. Smoking history demonstrated a significant difference across 3 radiographic cavitation patterns (P = 0.006). Hemoptysis was noted in 1 patient with cavity formation and 4 patients without, with no significant difference between the 2 groups. Conclusion: Tumoral cavitation occurred in 19% in patients with NSCLC treated with bevacizumab and demonstrated 3 radiographic patterns. Subsequent filling in of cavitation was noted in the majority of cases. PMID:22743083

  16. Sustainable Marketing

    NARCIS (Netherlands)

    Dam, van Y.K.

    2017-01-01

    In this article, three different conceptions of sustainable marketing are discussed and compared. These different conceptions are referred to as social, green, and critical sustainable marketing. Social sustainable marketing follows the logic of demand-driven marketing management and places the

  17. [Polyphenolic antioxidants efficiently protect urease from inactivation by ultrasonic cavitation].

    Science.gov (United States)

    Metelitsa, D I; Tarun, E I; Losev, Iu P

    2002-01-01

    Inactivation of urease (25 nM) in aqueous solutions (pH 5.0-6.0) treated with low-frequency ultrasound (LFUS; 27 kHz, 60 Wt/cm2, 36-56 degrees C) or high-frequency ultrasound (HFUS; 2.64 MHz, 1 Wt/cm2, 36 or 56 degrees C) has been characterized quantitatively, using first-order rate constants: kin, aggregate inactivation; kin*, thermal inactivation; and kin* (US), ultrasonic inactivation. Within the range from 1 nM to 10 microM, propyl gallate (PG) decreases approximately threefold the rate of LFUS-induced inactivation of urease (56 degrees C), whereas resorcinol poly-2-disulfide prevents this process at 1 nM or higher concentrations. PG completely inhibits HFUS-induced inactivation of urease at 1 nM (36 degrees C) or 10 nM (56 degrees C). At 0.2-10 microM, human serum albumin (HSA) increases the resistance of urease (at 56 degrees C) treated with HFUS to temperature- and cavitation-induced inactivation. Complexes of gallic acid polydisulfide (GAPDS) with HSA (GAPDS-HSA), formed by conjugation of 1.0 nM PGDS with 0.33 nM HSA, prevent HFUS-induced urease inactivation (56 degrees C).

  18. Sonoluminescence and dynamics of cavitation bubble populations in sulfuric acid.

    Science.gov (United States)

    Thiemann, Andrea; Holsteyns, Frank; Cairós, Carlos; Mettin, Robert

    2017-01-01

    The detailed link of liquid phase sonochemical reactions and bubble dynamics is still not sufficiently known. To further clarify this issue, we image sonoluminescence and bubble oscillations, translations, and shapes in an acoustic cavitation setup at 23kHz in sulfuric acid with dissolved sodium sulfate and xenon gas saturation. The colour of sonoluminescence varies in a way that emissions from excited non-volatile sodium atoms are prominently observed far from the acoustic horn emitter ("red region"), while such emissions are nearly absent close to the horn tip ("blue region"). High-speed images reveal the dynamics of distinct bubble populations that can partly be linked to the different emission regions. In particular, we see smaller strongly collapsing spherical bubbles within the blue region, while larger bubbles with a liquid jet during collapse dominate the red region. The jetting is induced by the fast bubble translation, which is a consequence of acoustic (Bjerknes) forces in the ultrasonic field. Numerical simulations with a spherical single bubble model reproduce quantitatively the volume oscillations and fast translation of the sodium emitting bubbles. Additionally, their intermittent stopping is explained by multistability in a hysteretic parameter range. The findings confirm the assumption that bubble deformations are responsible for pronounced sodium sonoluminescence. Notably the observed translation induced jetting appears to serve as efficient mixing mechanism of liquid into the heated gas phase of collapsing bubbles, thus potentially promoting liquid phase sonochemistry in general. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Luminescence from cavitation bubbles deformed in uniform pressure gradients

    Science.gov (United States)

    Supponen, Outi; Obreschkow, Danail; Kobel, Philippe; Farhat, Mohamed

    2017-09-01

    Presented here are observations that demonstrate how the deformation of millimetric cavitation bubbles by a uniform pressure gradient quenches single-collapse luminescence. Our innovative measurement system captures a broad luminescence spectrum (wavelength range, 300-900 nm) from the individual collapses of laser-induced bubbles in water. By varying the bubble size, driving pressure, and perceived gravity level aboard parabolic flights, we probed the limit from aspherical to highly spherical bubble collapses. Luminescence was detected for bubbles of maximum radii within the previously uncovered range, R0=1.5 -6 mm, for laser-induced bubbles. The relative luminescence energy was found to rapidly decrease as a function of the bubble asymmetry quantified by the anisotropy parameter ζ , which is the dimensionless equivalent of the Kelvin impulse. As established previously, ζ also dictates the characteristic parameters of bubble-driven microjets. The threshold of ζ beyond which no luminescence is observed in our experiment closely coincides with the threshold where the microjets visibly pierce the bubble and drive a vapor jet during the rebound. The individual fitted blackbody temperatures range between Tlum=7000 and Tlum=11 500 K but do not show any clear trend as a function of ζ . Time-resolved measurements using a high-speed photodetector disclose multiple luminescence events at each bubble collapse. The averaged full width at half-maximum of the pulse is found to scale with R0 and to range between 10 and 20 ns.

  20. Using the cavitation collapse time to indicate the extent of histotripsy-induced tissue fractionation.

    Science.gov (United States)

    Macoskey, Jonathan Jenner; Choi, Sang Won; Hall, Timothy L; Vlaisavljevich, Eli; Lundt, Jonathan Erik; Lee, Fred T; Johnsen, Eric; Cain, Charles A; Xu, Zhen

    2018-02-09

    Histotripsy is an ultrasonic tissue ablation method based on acoustic cavitation. It has been shown that cavitation dynamics change depending on the mechanical properties of the host medium. During histotripsy treatment, the target-tissue is gradually fractionated and eventually liquefied to acellular homogenate. In this study, the change in the collapse time (tcol) of the cavitation bubble cloud over the course of histotripsy treatment is investigated as an indicator for progression of the tissue fractionation process throughout treatment. A 500-kHz histotripsy transducer is used to generate single-location lesions within tissue-mimicking agar phantoms of varying stiffness levels as well as ex vivo bovine liver samples. Cavitation collapse signals are acquired with broadband hydrophones, and cavitation is imaged optically using a high-speed camera in transparent tissue-mimicking phantoms. The high-speed-camera-acquired measurements of tcol validate the acoustic hydrophone measurements. Increases in tcol are observed both with decreasing phantom stiffness and throughout histotripsy treatment with increasing number of pulses applied. The increasing trend of tcol throughout the histotripsy treatment correlates well with the progression of lesion formation generated in tissue-mimicking phantoms (R2 = 0.87). Finally, the increasing trend of tcol over the histotripsy treatment is validated in ex vivo bovine liver. © 2018 Institute of Physics and Engineering in Medicine.