  1. Survey instrument response to beta radiations

    International Nuclear Information System (INIS)

    Swinth, K.L.; Sisk, D.R.

    1990-01-01

    Available survey instruments do not have the beta measurement characteristics needed for accurate dose rate assessments. Such instruments have severe angular and energy dependence. In addition, beta measurements often require corrections for the source geometry response of the detector to permit accurate assessments. Studies were performed to characterize present instruments and to determine optimum characteristics for a field instrument. Results of the studies were used to specify and procure an instrument with improved characteristics. The purpose of this paper is to describe the results of the studies and the design of the instrument

  2. Survey of instruments for micrometeorology

    National Research Council Canada - National Science Library

    Monteith, John Lennox

    1972-01-01

    ... have been developed for micrometeorological measurements. Many of these instruments can be used by ecologists to measure and define the environment of plants and animals and to explore the ways in which organisms modify the environment they are exposed...

  3. Survey of instruments for micrometeorology

    National Research Council Canada - National Science Library

    Monteith, John Lennox

    1972-01-01

    .... Meteorologists are concerned with the behaviour of the boundary layer because it determines the input of heat, water vapour and momentum to the lower atmosphere and a large number of instruments...

  4. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  5. A survey instrument for measuring vaccine acceptance.

    Science.gov (United States)

    Sarathchandra, Dilshani; Navin, Mark C; Largent, Mark A; McCright, Aaron M

    2018-04-01

    Accurately measuring vaccine acceptance is important, especially under current conditions in which misinformation may increase public anxiety about vaccines and politicize vaccination policies. We integrated substantive knowledge, conceptualization and measurement expertise, and survey design principles to develop an instrument for measuring vaccine acceptance across the general public. Given this broad goal, we expect our novel instrument will complement, rather than replace, existing instruments designed specifically to measure parents' vaccine hesitancy. Our instrument measures five key facets of vaccine acceptance: (1) perceived safety of vaccines; (2) perceived effectiveness and necessity of vaccines; (3) acceptance of the selection and scheduling of vaccines; (4) positive values and affect toward vaccines; and (5) perceived legitimacy of authorities to require vaccinations. We report results of analyses demonstrating the reliability and validity of this instrument. High Cronbach's alpha values for five sub-scales and for the full scale indicate the instrument's reliability, and the consistent performance of expected predictors (i.e., trust in biologists, conspiratorial ideation, and political ideology) demonstrates the instrument's construct validity. Further, scientific reasoning increases vaccine acceptance among liberals but decreases vaccine acceptance among conservatives, which is consistent with motivated cognition. Also, trust in biologists has a stronger positive effect on vaccine acceptance among conservatives than among liberals, signaling a potentially promising means to reduce political polarization on vaccines and increase vaccine acceptance across the general public. We end by identifying key ways that public health researchers, science studies scholars, and health practitioners may employ the full (or short) version of our vaccine acceptance instrument. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. 10 CFR 35.61 - Calibration of survey instruments.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Calibration of survey instruments. 35.61 Section 35.61... § 35.61 Calibration of survey instruments. (a) A licensee shall calibrate the survey instruments used... or decade that will be used to show compliance; and (3) Conspicuously note on the instrument the date...

  7. 10 CFR 34.25 - Radiation survey instruments.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation survey instruments. 34.25 Section 34.25 Energy... INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.25 Radiation survey instruments. (a) The licensee shall keep sufficient calibrated and operable radiation survey instruments at each location where radioactive...

  8. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  9. New generation low power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Umbarger, C.J.; Wolf, M.A.

    1984-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and powersaving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Use of a capacitor as a power source eliminates many problems commonly associated with battery-operated instruments, such as having to open the case to change batteries, battery storage life, availability of batteries in the field, and some savings in weight. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  10. Survey of portable radiological instrumentation at 16 DOE sites

    Energy Technology Data Exchange (ETDEWEB)

    Coutts, G.W.; Hickman, D.

    1995-06-01

    The DOE-DP complex initiated a Radiological Instrument Standardization and Qualification Program to ensure the quality of radiological measurements within each DOE site. As part of the program, a complex-wide survey was conducted of all portable instruments in use at 16 DOE facilities. This paper presents the data gathered and suggests several possible standardization options.

  11. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  12. The Dark Energy Survey instrument design

    International Nuclear Information System (INIS)

    Flaugher, B.; Fermilab

    2006-01-01

    We describe a new project, the Dark Energy Survey (DES), aimed at measuring the dark energy equation of state parameter, w, to a statistical precision of ∼5%, with four complementary techniques. The survey will use a new 3 sq. deg. mosaic camera (DECam) mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). DECam includes a large mosaic camera, a five element optical corrector, four filters (g,r,i,z), and the associated infrastructure for operation in the prime focus cage. The focal plane consists of 62 2K x 4K CCD modules (0.27''/pixel) arranged in a hexagon inscribed within the 2.2 deg. diameter field of view. We plan to use the 250 micron thick fully-depleted CCDs that have been developed at the Lawrence Berkeley National Laboratory (LBNL). At Fermilab, we will establish a packaging factory to produce four-side buttable modules for the LBNL devices, as well as to test and grade the CCDs. R and D is underway and delivery of DECam to CTIO is scheduled for 2009

  13. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  14. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Applications of Calendar Instruments in Social Surveys: a review

    NARCIS (Netherlands)

    Glasner, T.J.; Vaart, van der W.

    2009-01-01

    Retrospective reports in survey interviews and questionnaires are subject to many types of recall error, which affect completeness, consistency, and dating accuracy. Concerns about this problem have led to the development of so-called calendar instruments, or timeline techniques. These aided recall

  16. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  17. Development of an RDECOM workforce motivational survey instrument

    OpenAIRE

    Avato, Jennifer B.; Folck, Dawn M.; Gachupin, Samuel R.

    2016-01-01

    Approved for public release; distribution is unlimited In order to improve the morale and raise the level of workforce productivity, it is critical to understand trends in an individual's motivational factors. We developed a closed-loop survey instrument and analysis methodology to identify distinct generational workforce motivational factors. Nine United States Army Research Development and Engineering Command (RDECOM) supervisory engineers, General Schedule (GS) 14 and 15, reviewed the s...

  18. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  19. Human factors survey of advanced instrumentation and controls

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    A survey oriented towards identifying the human factors issues in regard to the use of advanced instrumentation and controls (I ampersand C) in the nuclear industry was conducted. A number of United States (US) and Canadian nuclear vendors and utilities were participants in the survey. Human factors items, subsumed under the categories of computer-generated displays (CGD), controls, organizational support, training, and related topics, were discussed. The survey found the industry to be concerned about the human factors issues related to the implementation of advanced I ampersand C. Fifteen potential human factors problems were identified. They include: the need for an advanced I ampersand C guideline equivalent to NUREG-0700; a role change in the control room from operator to supervisor; information overload; adequacy of existing training technology for advanced I ampersand C; and operator acceptance and trust. 11 refs., 1 tab

  20. Measurements with the new PHE neutron survey instrument

    International Nuclear Information System (INIS)

    Eakins, J.S.; Tanner, R.J.; Hager, L.G.

    2014-01-01

    A novel design of survey instrument has been developed to accurately estimate ambient dose equivalent from neutrons with energies in the range from thermal to 20 MeV. The device features moderating and attenuating layers to ease measurement of fast and intermediate energy neutrons, combined with guides that channel low-energy neutrons to the single, central detector. A prototype of this device has been constructed and exposed to a set of calibration fields: the resulting measured responses are presented and discussed here, and compared against Monte Carlo data. A simple simulated workplace neutron field has also been developed to test the device. Measured response data have been determined for a prototype design of neutron survey instrument, using facilities at PHE and NPL. In general, the results demonstrated good directional invariance and agreed well with data obtained by Monte Carlo modelling, raising confidence in the accuracy of the response characteristics expected for the device. A simple simulated workplace field has also been developed and characterised, and the performance of the device assessed in it: agreement between measured and modelled results suggests that the device would behave as anticipated in real workplace fields. These performances will be investigated further in the future, as the design makes the transition from a research prototype to a commercially available instrument. (authors)

  1. Calibration of the GNU and HSREM neutron survey instruments

    International Nuclear Information System (INIS)

    Eakins, J.S.; Hager, L.G.; Leake, J.W.; Mason, R.S.; Tanner, R.J.

    2017-01-01

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  2. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  3. Current instrument reprocessing practices. Results of a national survey.

    Science.gov (United States)

    Muscarella, L F

    2001-01-01

    In June 1998, a questionnaire was mailed to approximately 2,900 healthcare professionals to assess current instrument reprocessing and infection control practices and determine whether they have changed during the past decade. Surveys were returned from 146 respondents whose facilities performed gastrointestinal endoscopy. Most respondents were registered nurses and almost all worked in healthcare facilities located in the United States. More than 75% of the respondents reported that infection control practices in endoscopy have improved during the past 10 years. Most respondents used glutaraldehyde to reprocess flexible endoscopes. Immersing endoscopes for 20 minutes at room temperature was commonly practiced. Almost 75% of respondents used an automated device to reprocess flexible endoscopes. Most respondents terminally rinsed the endoscope's channels with 70% alcohol followed by forced-air drying. Few respondents outsourced instruments to a commercial reprocessing company and almost 50% reused disposable items. While some practices in endoscope reprocessing have changed during the past several years, others have not. In general, infection controls appear to have improved during the past decade, with the possible exception of a trend to reuse single-use items.

  4. How Harmful are Survey Translations? A Test with Schwartz’s Human Values Instrument

    NARCIS (Netherlands)

    Davidov, E.; Beuckelaer, A. de

    2010-01-01

    One major challenge in international survey research is to ensure the equivalence of translated survey instruments across different cultures. In this study, we examine empirically the extent to which equivalence of survey instruments to measure human values can be established across cultures sharing

  5. Validation of screening instruments for neuroepidemiological surveys of tic disorders.

    Science.gov (United States)

    Cubo, Esther; Sáez Velasco, Sara; Delgado Benito, Vanesa; Villaverde, Vanesa Ausín; Gabriel Y Galán, Jose Maria Trejo; Santidrián, Asuncion Martín; Vicente, Jesús Macarrón; Guevara, José Cordero; Louis, Elan D; Benito-León, Julian

    2011-02-15

    The main purpose was to validate a multistage protocol to screen tic disorders in mainstream and special education centers and to investigate whether telephone-based interviews were accurate to diagnose tic disorders when compared with in-person neurological interviews. A school-based survey of children and adolescents (6-16 years). A proxy report questionnaire for tic disorders was completed by teachers, observers, and parents. The diagnosis was confirmed by the neurologist based on the Diagnostic and Statistical Manual of Mental disorders (DSM-IV TR) criteria. The sensitivity, specificity, positive and negative predictive values, the likelihood ratio for a positive result (LR+), and the Kappa coefficients (k) for telephone-based interviews reliability were calculated. One hundred twenty subjects, 57 from special education center and 63 from a mainstream school were studied. The sensitivity of the proxy report questionnaire was 58% and 36% when completed by the observers (mainstream and special education center, respectively), 40 and 73% when completed by the teachers, and 58 and 36% when completed by the parents. Using any of these 3 screening sources, the sensitivity was 92%, the positive predictive value was 38%, and negative predictive value was 97% (mainstream schools), whereas the sensitivity was 82%, the positive predictive value was 20%, and negative predictive value was 82% (special education centers). Parents (mainstream schools) and teachers (special education center) produced the highest LR+ (7.25 and 1.26, respectively) and the intraobserver reliability of the telephone-based interviews versus in-person neurological interviews gave a k coefficient of 0.83. The efficiency of different screening instruments for tic disorders seems to vary in different settings. Telephone-based interviews may be a valid and convenient backup to ascertain the diagnosis of tic disorders when face-to-face neurological examination is not possible. Copyright © 2011 Movement

  6. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  7. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  8. Measuring teamwork in health care settings: a review of survey instruments.

    Science.gov (United States)

    Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C

    2015-04-01

    Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.

  9. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  10. BUSINESS SURVEYS-EVALUATION INSTRUMENT OF THE EUROPEAN ECONOMIC CLIMATE

    Directory of Open Access Journals (Sweden)

    SECAREANU CONSTANTIN

    2010-07-01

    Full Text Available Business surveys or conjuncture surveys are specific statiostical researches, but complementary to traditional, official statistics.While official statistics provide quantitive information regardin the level,structure and evolution of varied economic process and phenomena, business surveys offer quality information, essential to the short term evolutional analysis of economic indicators: the diagnosis of the current situation, the timely detection of inflexion points within the economic cycle and the rapid estimation of short term tendencies of the main macroeconomic indicators (the dynamics of the gross domestic product, the index of industrial production, etc.

  11. Survey of instrumentation used for monitoring metals in water

    Energy Technology Data Exchange (ETDEWEB)

    Quinby-Hunt, M.S.

    1978-06-01

    A study was conducted of instrumentation used to determine metals in water. Several of the techniques most commonly used for analysis and routine determinations of metals in water are shown in Table 1. They are atomic absorption spectroscopy, both flame and flameless, atomic emission spectroscopy using conventional flame sources and inductively-coupled plasma sources, and ultraviolet-visible absorption techniques. Other less frequently employed methods are x-ray fluorescence analysis using both photon and charged particle excitation with energy-dispersive and wavelength-dispersive spectral analysis. Also electrochemical techniques and activation analysis are studied.

  12. Questionnaire surveys on health and working conditions: development of an instrument for risk assessment in companies

    NARCIS (Netherlands)

    Weel, A. N.; Broersen, J. P.; van Dijk, F. J.

    2000-01-01

    Periodic Occupational Health Surveys (POHS) are frequently used by occupational health and safety services in the Netherlands as a risk assessment instrument. These surveys include a questionnaire on work and health. Systematic attention is paid in this questionnaire to a broad range of working

  13. The Multi-sensor Airborne Radiation Survey (MARS) Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Fast, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Aalseth, Craig E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Asner, David M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bonebrake, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Day, Anthony R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dorow, Kevin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fuller, Erin S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glasgow, Brian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hossbach, Todd W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hyronimus, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jensen, Jeffrey L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Kenneth I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jordan, David V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Morgen, Gerald P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Morris, Scott J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mullen, O Dennis [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Myers, Allan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pitts, W. Karl [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rohrer, John S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Runkle, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Seifert, Allen [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Shergur, Jason M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stave, Sean C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tatishvili, Gocha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Thompson, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Todd, Lindsay C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Warren, Glen A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willett, Jesse A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wood, Lynn S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-11

    The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gama ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach, we found, is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. Moreover, the system is ruggedized and shock mounted for use in a variety of field applications, including airborne and maritime operations.

  14. Comparing NICU teamwork and safety climate across two commonly used survey instruments

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-01-01

    Background and objectives Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Methods Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. Results We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Conclusions Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. PMID:26700545

  15. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    Science.gov (United States)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  16. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  17. Evaluation and Monte Carlo modelling of the response function of the Leake neutron area survey instrument

    International Nuclear Information System (INIS)

    Tagziria, H.; Tanner, R.J.; Bartlett, D.T.; Thomas, D.J.

    2004-01-01

    All available measured data for the response characteristics of the Leake counter have been gathered together. These data, augmented by previously unpublished work, have been compared to Monte Carlo simulations of the instrument's response characteristics in the energy range from thermal to 20 MeV. A response function has been derived, which is recommended as the best currently available for the instrument. Folding this function with workplace energy distributions has enabled an assessment of the impact of this new response function to be made. Similar work, which will be published separately, has been carried out for the NM2 and the Studsvik 2202D neutron area survey instruments

  18. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  19. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  20. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  1. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  2. Development and validation of a survey instrument to measure children's advertising literacy

    NARCIS (Netherlands)

    Rozendaal, E.; Opree, S.J.; Buijzen, M.A.

    2016-01-01

    The aim of this study was to develop and validate a survey measurement instrument for children's advertising literacy. Based on the multidimensional conceptualization of advertising literacy by 0056"> Rozendaal, Lapierre, Van Reijmersdal, and Buijzen (2011), 39 items were created to measure two

  3. A Survey of the Characteristics and Perceptions of Urban and Suburban Secondary Instrumental Music Teachers

    Science.gov (United States)

    Fitzpatrick, Kate R.

    2013-01-01

    The purpose of this study was to survey and compare the characteristics and perceptions of randomly selected urban and suburban (N=20) secondary instrumental music teachers in the Chicago area. Descriptive analysis of the demographic data demonstrated the following: suburban participants had higher levels of educational attainment than their urban…

  4. Student Interest in Technology and Science (SITS) Survey: Development, Validation, and Use of a New Instrument

    Science.gov (United States)

    Romine, William; Sadler, Troy D.; Presley, Morgan; Klosterman, Michelle L.

    2014-01-01

    This study presents the systematic development, validation, and use of a new instrument for measuring student interest in science and technology. The Student Interest in Technology and Science (SITS) survey is composed of 5 sub-sections assessing the following dimensions: interest in learning science, using technology to learn science, science…

  5. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. A Systematic Survey Instrument Translation Process for Multi-Country, Comparative Health Workforce Studies

    Science.gov (United States)

    Squires, Allison; Aiken, Linda H.; van den Heede, Koen; Sermeus, Walter; Bruyneel, Luk; Lindqvist, Rikard; Schoonoven, Lisette; Stromseng, Ingeborg; Busse, Reinhard; Brozstek, Tomas; Ensio, Anneli; Moreno-Casbas, Mayte; Rafferty, Anne Marie; Schubert, Maria; Zikos, Dimitris

    2012-01-01

    Background As health services research (HSR) expands across the globe, researchers will adopt health services and health worker evaluation instruments developed in one country for use in another. This paper explores the cross-cultural methodological challenges involved in translating HSR in the language and context of different health systems. Objectives To describe the pre-data collection systematic translation process used in a twelve country, eleven language nursing workforce survey. Design & Settings We illustrate the potential advantages of Content Validity Indexing (CVI) techniques to validate a nursing workforce survey developed for RN4CAST, a twelve country (Belgium, England, Finland, Germany, Greece, Ireland, Netherlands, Norway, Poland, Spain, Sweden, and Switzerland), eleven language (with modifications for regional dialects, including Dutch, English, Finnish, French, German, Greek, Italian, Norwegian, Polish, Spanish, and Swedish), comparative nursing workforce study in Europe. Participants Expert review panels comprised of practicing nurses from twelve European countries who evaluated cross-cultural relevance, including translation, of a nursing workforce survey instrument developed by experts in the field. Methods The method described in this paper used Content Validity Indexing (CVI) techniques with chance correction and provides researchers with a systematic approach for standardizing language translation processes while simultaneously evaluating the cross-cultural applicability of a survey instrument in the new context. Results The cross-cultural evaluation process produced CVI scores for the instrument ranging from .61 to .95. The process successfully identified potentially problematic survey items and errors with translation. Conclusions The translation approach described here may help researchers reduce threats to data validity and improve instrument reliability in multinational health services research studies involving comparisons across

  7. A systematic survey instrument translation process for multi-country, comparative health workforce studies.

    Science.gov (United States)

    Squires, Allison; Aiken, Linda H; van den Heede, Koen; Sermeus, Walter; Bruyneel, Luk; Lindqvist, Rikard; Schoonhoven, Lisette; Stromseng, Ingeborg; Busse, Reinhard; Brzostek, Tomasz; Ensio, Anneli; Moreno-Casbas, Mayte; Rafferty, Anne Marie; Schubert, Maria; Zikos, Dimitris; Matthews, Anne

    2013-02-01

    As health services research (HSR) expands across the globe, researchers will adopt health services and health worker evaluation instruments developed in one country for use in another. This paper explores the cross-cultural methodological challenges involved in translating HSR in the language and context of different health systems. To describe the pre-data collection systematic translation process used in a twelve country, eleven language nursing workforce survey. We illustrate the potential advantages of Content Validity Indexing (CVI) techniques to validate a nursing workforce survey developed for RN4CAST, a twelve country (Belgium, England, Finland, Germany, Greece, Ireland, Netherlands, Norway, Poland, Spain, Sweden, and Switzerland), eleven language (with modifications for regional dialects, including Dutch, English, Finnish, French, German, Greek, Italian, Norwegian, Polish, Spanish, and Swedish), comparative nursing workforce study in Europe. Expert review panels comprised of practicing nurses from twelve European countries who evaluated cross-cultural relevance, including translation, of a nursing workforce survey instrument developed by experts in the field. The method described in this paper used Content Validity Indexing (CVI) techniques with chance correction and provides researchers with a systematic approach for standardizing language translation processes while simultaneously evaluating the cross-cultural applicability of a survey instrument in the new context. The cross-cultural evaluation process produced CVI scores for the instrument ranging from .61 to .95. The process successfully identified potentially problematic survey items and errors with translation. The translation approach described here may help researchers reduce threats to data validity and improve instrument reliability in multinational health services research studies involving comparisons across health systems and language translation. Copyright © 2012 Elsevier Ltd. All rights

  8. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    Science.gov (United States)

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  9. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  10. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    Science.gov (United States)

    Harris, Laura Florence; Awoonor-Williams, John Koku; Gerdts, Caitlin; Gil Urbano, Laura; González Vélez, Ana Cristina; Halpern, Jodi; Prata, Ndola; Baffoe, Peter

    2016-01-01

    Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision. A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana. The model posits three domains of conscientious objection that form the basis for the survey instrument: 1) beliefs about abortion and conscientious objection; 2) actions related to conscientious objection and abortion; and 3) self-identification as a conscientious objector. The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  11. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    Directory of Open Access Journals (Sweden)

    Laura Florence Harris

    Full Text Available Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision.A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana.The model posits three domains of conscientious objection that form the basis for the survey instrument: 1 beliefs about abortion and conscientious objection; 2 actions related to conscientious objection and abortion; and 3 self-identification as a conscientious objector.The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  12. Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-12-31

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs.

  13. A Survey Instrument for Measuring the Experiential Value of Employee-Tourist Encounters

    DEFF Research Database (Denmark)

    Mattsson, Jan; Sørensen, Flemming; Jensen, Jens Friis

    In this paper, we develop and test a survey instrument that aims at estimating the experiential value of employee-tourist encounters in destination-based tourism companies, as well as the characteristics of encounters that affect such experiential value. We suggest that such an instrument can...... inform research as well as tourist organisations about how to facilitate employee-tourist encounters that create experiential value for tourists and subsequently affect tourists’ memory of experiences. This knowledge is crucial for tourism companies that aim at creating experiential value...... for their visitors, rather than simply delivering service quality....

  14. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    Science.gov (United States)

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  15. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India

    Science.gov (United States)

    Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-01-01

    Introduction The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. Aim The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. Materials and Methods A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher’s-exact test and the Chi-Square test. Results Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. Conclusion A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced

  16. Identifying the Barriers to Using Games and Simulations in Education: Creating a Valid and Reliable Survey Instrument

    Science.gov (United States)

    Justice, Lenora Jean

    2012-01-01

    The purpose of this study was to create a valid and reliable instrument to measure teacher perceived barriers to the adoption of games and simulations in instruction. Previous research, interviews with educators, a focus group, an expert review, and a think aloud protocol were used to design a survey instrument. After finalization, the survey was…

  17. Marine oil pollution and beached bird surveys: the development of a sensitive monitoring instrument

    International Nuclear Information System (INIS)

    Camphuysen, C.J.; Heubeck, M.

    2001-01-01

    One of the most obvious adverse effects of (chronic) pollution of the world's oceans and seas with mineral oil is the mortality of seabirds. Systematic surveys of beachcast corpses of birds ('beached bird surveys') have been used in many parts of the world to document the effect of oil pollution, but particularly so in Western Europe and in parts of North America. In this paper, the history, current schemes, methods and possible (future) use of beached bird surveys are described and discussed, because the value of beached bird surveys has been hotly disputed. Oil pollution is known since the late 19 th century, while the first beached bird surveys were conducted in the 1920s. Due to the amount of man-power needed for these surveys, most beached bird survey programs thrived only through the work of a large number of volunteers. However, most programs have resulted in substantial amounts of high quality data, often covering many consecutive years. One of the main shortcomings of many beached bird survey programs was the emphasis on stranded bird numbers rather than on relative measures, such as oil rates (percentage of corpses oiled of all corpses found). Sources of pollution, particularly so in chronically polluted regions such as the North Sea, the Baltic, the Mediterranean and the waters around Newfoundland, are insufficiently known, but could be studied through a sampling program connected to beached bird surveys. Suggestions for standardization of methods are presented, which could lead to a global and highly sensitive monitoring instrument of marine oil pollution. (Author)

  18. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  19. Quality of persian addiction websites: a survey based on silberg, discern and wqet instruments (2011).

    Science.gov (United States)

    Zahedi, Razieh; Taheri, Behjat; Shahrzadi, Leila; Tazhibi, Mehdi; Ashrafi-rizi, Hasan

    2013-03-01

    Nowadays, World Wide Web is an accessible and widespread resource to attain medical information. So physicians and health institutions try to inform patients about different domains of medicine through Web. Addiction is a noteworthy subject in medicine and a controversial issue among them. However, quality of health information on the internet is doubtful. The objective of this study is to determine the quality of Persian addiction websites to offer recommendation for their improvement. This was survey and an applied study that the study population was all Persian addiction websites. Sample of this study was 28 Persian addiction website which were chosen by searching Persian equivalences of 7 key terms (addiction, addict, addiction center, drug, treatment of addiction, recovery of addiction, addiction withdrawal) into the Google and Yahoo search engines. Finally, the websites were ranked based on the Silberg, DISCERN and WQET instruments. Data were analyzed with Excel software using descriptive statistics. The overall mean of websites in Silberg, DISCERN and WQET instruments were 1.42, 41.89, 64.57. Also the results showed that "Unit of Substance Abuse Treatment" belonging to Mashhad University of Medical Sciences was ranked first based on the Silberg, DISCERN and WQET instruments. 5 (from total of 9), 60 (from total of 80) and 82 (from total of normalized grade 82) were grades for this website for these instruments respectively. It showed that the quality of Persian websites according to Silberg, DISCERN and WQET instruments was "low", "more than half" and "very good" respectively. Not assigning date of entering data, author names, and references of information (authority) were most important missing characteristics of these websites. In addition, lack of interactive opportunities like chat rooms was another problem that leads to dissatisfaction of users.

  20. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    Science.gov (United States)

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  1. Review of the Literature on Survey Instruments Used to Collect Data on Hospital Patients' Perceptions of Care

    Science.gov (United States)

    Castle, Nicholas G; Brown, Julie; Hepner, Kimberly A; Hays, Ron D

    2005-01-01

    Objective To review the existing literature (1980–2003) on survey instruments used to collect data on patients' perceptions of hospital care. Study Design Eight literature databases were searched (PubMED, MEDLINE Pro, MEDSCAPE, MEDLINEplus, MDX Health, CINAHL, ERIC, and JSTOR). We undertook 51 searches with each of the eight databases, for a total of 408 searches. The abstracts for each of the identified publications were examined to determine their applicability for review. Methods of Analysis For each instrument used to collect information on patient perceptions of hospital care we provide descriptive information, instrument content, implementation characteristics, and psychometric performance characteristics. Principal Findings The number of institutional settings and patients used in evaluating patient perceptions of hospital care varied greatly. The majority of survey instruments were administered by mail. Response rates varied widely from very low to relatively high. Most studies provided limited information on the psychometric properties of the instruments. Conclusions Our review reveals a diversity of survey instruments used in assessing patient perceptions of hospital care. We conclude that it would be beneficial to use a standardized survey instrument, along with standardization of the sampling, administration protocol, and mode of administration. PMID:16316435

  2. Psychometric properties of the Dutch version of the Hospital-level Consumer Assessment of Health Plans Survey instrument.

    NARCIS (Netherlands)

    Arah, O.A.; Asbroek, A.H.A. ten; Delnoij, D.M.J.; Koning, J.S. de; Stam, P.J.A.; Poll, A.H.; Vriens, B.; Schmidt, P.F.; Klazinga, N.S.

    2006-01-01

    Objectives: To assess the reliability and validity of a translated version of the American Hospital-level Consumer Assessment of Health Plans Survey® (H-CAHPS) instrument for use in Dutch health care. Data Sources/Study Setting: Primary survey data from adults aged 18 years or more who were recently

  3. Psychometric properties of the Dutch version of the Hospital-level Consumer Assessment of Health Plans Survey instrument

    NARCIS (Netherlands)

    Arah, Onyebuchi A.; ten Asbroek, A. H. A.; Delnoij, Diana M. J.; de Koning, Johan S.; Stam, Piet J. A.; Poll, Aldien H.; Vriens, Barbara; Schmidt, Paul F.; Klazinga, Niek S.

    2006-01-01

    OBJECTIVES: To assess the reliability and validity of a translated version of the American Hospital-level Consumer Assessment of Health Plans Survey (H-CAHPS) instrument for use in Dutch health care. DATA SOURCES/STUDY SETTING: Primary survey data from adults aged 18 years or more who were recently

  4. Psychometric properties of the Dutch version of the Hospital-level Consumer Assessment of Health Plans Survey instrument.

    NARCIS (Netherlands)

    Arah, Onyebuchi A; Asbroek, A H A ten; Delnoij, Diana M J; de Koning, Johan S; Stam, Piet J A; Poll, Aldien H; Vriens, Barbara; Schmidt, Paul F; Klazinga, Niek S

    2006-01-01

    OBJECTIVES: To assess the reliability and validity of a translated version of the American Hospital-level Consumer Assessment of Health Plans Survey (H-CAHPS) instrument for use in Dutch health care. DATA SOURCES/STUDY SETTING: Primary survey data from adults aged 18 years or more who were recently

  5. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    Science.gov (United States)

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Physicians' knowledge of the epidemiology, diagnosis, and management of otitis media: design of a survey instrument.

    Science.gov (United States)

    Lee, Ambrose; Flowerdew, Gordon; Delaney, Mary

    2009-01-01

    To develop a survey instrument with good internal consistency and test-retest reliability to explore the level of knowledge among Nova Scotia family physicians concerning the risk factors, signs and symptoms, and treatment of otitis media and the use of pneumatic otoscopy. Prospective cohort design. Fee-for-service family practices in Nova Scotia. A convenience sample of 25 family physicians. Test-retest reliability and internal consistency of the survey. The constructs including "signs and symptoms of otitis media with effusion" and "comprehensive knowledge scores" showed excellent internal consistency with Kuder-Richardson 20 scores greater than 0.7 whereas the construct "signs and symptoms of acute otitis media" has a Kuder-Richardson 20 score of 0.54 after deletion of several items. The Cohen kappa and Spearman rho tests showed the survey has very good test-retest reliability. The questionnaire that we developed proved to have very good internal consistency and test-retest reliability. We hope to use this questionnaire to explore the practice patterns of family physicians in managing otitis media disease.

  7. Measuring Social Exclusion in Routine Public Health Surveys: Construction of a Multidimensional Instrument

    Science.gov (United States)

    van Bergen, Addi P. L.; Hoff, Stella J. M.; van Ameijden, Erik J. C.; van Hemert, Albert M.

    2014-01-01

    Introduction Social exclusion is considered a major factor in the causation and maintenance of health inequalities, but its measurement in health research is still in its infancy. In the Netherlands the Institute for Social Research (SCP) developed an instrument to measure the multidimensional concept of social exclusion in social and economic policy research. Here, we present a method to construct a similar measure of social exclusion using available data from public health surveys. Methods Analyses were performed on data from the health questionnaires that were completed by 20,877 adults in the four largest cities in the Netherlands. From each of the four questionnaires we selected the items that corresponded to those of the SCP-instrument. These were entered into a nonlinear canonical correlation analysis. The measurement properties of the resulting indices and dimension scales were assessed and compared to the SCP-instrument. Results The internal consistency of the indices and most of the dimension scales were adequate and the internal structure of the indices was as expected. Both generalisabiliy and construct validity were good: in all datasets strong associations were found between the index and a number of known risk factors of social exclusion. A limitation of content validity was that the dimension “lack of normative integration” could not be measured, because no relevant items were available. Conclusions Our findings indicate that a measure for social exclusion can be constructed with available health questionnaires. This provides opportunities for application in public health surveillance systems in the Netherlands and elsewhere in the world. PMID:24878842

  8. Dental Management Survey Brazil (DMS-BR): creation and validation of a management instrument

    Science.gov (United States)

    Gonzales, Paola Sampaio; Martins, Ismar Eduardo; Biazevic, Maria Gabriela Haye; Silva, Paulo Roberto da; Michel-Crosato, Edgard

    2017-04-10

    Questionnaires for the assessment of knowledge and self-perception can be useful to diagnose what a dentist knows about management and administration. The aim of the present study was to create and validate the Dental Management Survey Brazil (DMS-BR) scale, based on meetings with experts in the field. After having elaborated the first version, 10 audits were performed in dental offices in order to produce the final version, which included nine dimensions: location, patient, finance, marketing, competition, quality, staff, career, and productivity. The accuracy of the instrument was measured by intrarater and interrater reliability. In the validation phase, 247 Brazilian dentists answered a web-based questionnaire. The data were processed using Stata 13.0 and the significance level was set at 95%. The instrument had intrarater and interrater reliability (ICC-0.93 and 0.94). The overall average of respondents for the DMS-BR scale was 3.77 (SD = 0.45). Skewness and kurtosis were below absolute values 3 and 7, respectively. Internal validity measured by Cronbach's alpha was 0.925 and the correlation of each dimension with the final result of the DMS-BR ranged between 0.606 and 0.810. Correlation with the job satisfaction scale was 0.661. The SEM data ranged between 0.80 and 0.56. The questionnaire presented satisfactory indicators of dentists' self-perception about management and administration activities.

  9. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    Science.gov (United States)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  10. A survey of Galileo plasma wave instrument observations of Jovian whistler-mode chorus

    Directory of Open Access Journals (Sweden)

    J. D. Menietti

    2008-07-01

    Full Text Available A survey of plasma wave observations at Jupiter obtained by the plasma wave instrument on board the Galileo spacecraft is presented. The observations indicate that chorus emissions are observed commonly in the Jovian magnetosphere near the magnetic equator in the approximate radial range 6survey includes almost all local times but not equally sampled in radial distance due to the spacecraft trajectory. The data suggest that chorus emissions are somewhat more intense on the dayside, but this may be a result of insufficient nightside observations. The orbit of Galileo is also restricted to ±3° of the Jovigraphic equator, but the tilt of the magnetic field permits coverage of a range of magnetic latitudes of −13°<λmag<+13°. The similarities of chorus emissions to terrestrial observations are a good reason to speculate that Jovian chorus emission may play a significant role in the stochastic acceleration of electrons in the radial range 6–10 RJ as recent studies indicate. These electrons may then be transported inward by radial diffusion where they are additionally accelerated to form the synchrotron radiation belt source.

  11. A survey of Galileo plasma wave instrument observations of Jovian whistler-mode chorus

    Directory of Open Access Journals (Sweden)

    J. D. Menietti

    2008-07-01

    Full Text Available A survey of plasma wave observations at Jupiter obtained by the plasma wave instrument on board the Galileo spacecraft is presented. The observations indicate that chorus emissions are observed commonly in the Jovian magnetosphere near the magnetic equator in the approximate radial range 6<r<10 RJ. The survey includes almost all local times but not equally sampled in radial distance due to the spacecraft trajectory. The data suggest that chorus emissions are somewhat more intense on the dayside, but this may be a result of insufficient nightside observations. The orbit of Galileo is also restricted to ±3° of the Jovigraphic equator, but the tilt of the magnetic field permits coverage of a range of magnetic latitudes of −13°<λmag<+13°. The similarities of chorus emissions to terrestrial observations are a good reason to speculate that Jovian chorus emission may play a significant role in the stochastic acceleration of electrons in the radial range 6–10 RJ as recent studies indicate. These electrons may then be transported inward by radial diffusion where they are additionally accelerated to form the synchrotron radiation belt source.

  12. Towards the development of an outcome instrument for spinal trauma: an international survey of spinal surgeons.

    Science.gov (United States)

    Oner, F Cumhur; Sadiqi, Said; Lehr, A Mechteld; Dvorak, Marcel F; Aarabi, Bizhan; Chapman, Jens R; Fehlings, Michael G; Kandziora, Frank; Rajasekaran, S; Vaccaro, Alexander R

    2015-01-15

    International web-based survey. To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. There is no universally accepted outcome instrument available that is specifically designed or validated for spinal trauma patients, contributing to controversies related to the optimal treatment and evaluation of many types of spinal injuries. Therefore, the AOSpine Knowledge Forum Trauma aims to develop such an instrument using the International Classification of Functioning, Disability, and Health (ICF) as its basis. Experts from the 5 AOSpine International world regions were asked to give their opinion on the relevance of a compilation of 143 ICF categories for spinal trauma patients on a 3-point scale: "not relevant," "probably relevant," or "definitely relevant." The responses were analyzed using frequency analysis. Possible differences in responses between the 5 world regions were analyzed with the Fisher exact test and descriptive statistics. Of the 895 invited AOSpine International members, 150 (16.8%) participated in this study. A total of 13 (9.1%) ICF categories were identified as definitely relevant by more than 80% of the participants. Most of these categories were related to the ICF component "activities and participation" (n = 8), followed by "body functions" (n = 4), and "body structures" (n = 1). Only some minor regional differences were observed in the pattern of answers. More than 80% of an international group of health care professionals experienced in the clinical care of adult spinal trauma patients indicated 13 of 143 ICF categories as definitely relevant to measure outcomes after spinal trauma. This study creates an evidence base to define a core set of ICF categories for outcome measurement in adult spinal trauma patients.

  13. A frailty instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE).

    LENUS (Irish Health Repository)

    Romero-Ortuno, Roman

    2010-01-01

    A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http:\\/\\/www.share-project.org), a large population-based survey conducted in 2004-2005 in twelve European countries.

  14. Economic instruments for obesity prevention: results of a scoping review and modified delphi survey

    Directory of Open Access Journals (Sweden)

    LaFrance Jeffrey

    2011-10-01

    Full Text Available Abstract Background Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity, and to make specific recommendations for the Canadian context. Methods Arksey and O'Malley's (2005 methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1 a structured literature search and review, and 2 consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Results Two key findings from the scoping review included 1 consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2 very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. Conclusions In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy

  15. Upward Transfer in STEM Fields of Study: A New Conceptual Framework and Survey Instrument for Institutional Research

    Science.gov (United States)

    Wang, Xueli

    2016-01-01

    This chapter describes a new conceptual framework that informs research on factors influencing transfer in STEM fields of study from 2-year to 4-year institutions, presents a new survey instrument based on the framework, and offers directions for future research in this area.

  16. Design of a Quality Schools Survey Instrument through the Use of a Four-Cycle Action Research Process.

    Science.gov (United States)

    Dryden, John

    The Quality Schools Consortium is composed of approximately 140 elementary, middle, and high schools in North America. An action research project was conducted to develop and refine a survey instrument to determine the perceptions of principals in the Quality Schools consortium with regard to the interpretation and implementation of the Quality…

  17. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    Science.gov (United States)

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  18. Probabilistic safety assessment for instrumentation and control systems in nuclear power plants. A literature survey

    International Nuclear Information System (INIS)

    Lu, Lixuan; Jiang, Jin

    2003-01-01

    Deregulation in electricity market will create a great deal of challenges for Nuclear Power Plants (NPP). To stay competitive, NPP will need to find new ways to reduce their operation costs. In NPP, Instrumentation and Control (I and C) systems play an important role in reducing the cost of producing electricity while maintaining and/or enhancing safety. Therefore, it is extremely important that one should manage the I and C systems more efficiently and economically. Meanwhile, obsolescence problem associated with I and C systems encouraged the usage of advanced digital techniques in I and C systems. Thus, new methodologies are needed to analyze the reliability and determine the maintenance strategy for the digital I and C systems. Probabilistic Safety Assessment (PSA) has been probed to be a promising method to deal with this issue. This paper provides a literature survey on the development of digital I and C systems in NPP, followed by a detailed review of PSA including its benefits, limitations and the future direction of its development. Most importantly, potential applications of PSA in various aspects of I and C systems are brought into perspective throughout the paper. Furthermore, the applicability of PSA in the regulation of safety-related I and C systems is demonstrated. Detailed information on PSA applications in 1) the resource allocation for I and C systems: 2) the determination of surveillance testing strategies; and 3) I and C system designs, is provided. (author)

  19. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Science.gov (United States)

    Klockenkämper, Reinhold; von Bohlen, Alex

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects.

  20. New Instruments for Survey: on Line Softwares for 3d Recontruction from Images

    Science.gov (United States)

    Fratus de Balestrini, E.; Guerra, F.

    2011-09-01

    3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation) to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting), acquisition tools (digital cameras) and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings. The research

  1. NEW INSTRUMENTS FOR SURVEY: ON LINE SOFTWARES FOR 3D RECONTRUCTION FROM IMAGES

    Directory of Open Access Journals (Sweden)

    E. Fratus de Balestrini

    2012-09-01

    Full Text Available 3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting, acquisition tools (digital cameras and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings

  2. Understanding nature's particle accelerators using high energy gamma-ray survey instruments

    Science.gov (United States)

    Abeysekara, Anushka Udara

    Nature's particle accelerators, such as Pulsars, Pulsar Wind Nebulae, Active Galactic Nuclei and Supernova Remnants accelerate charged particles to very high energies that then produce high energy photons. The particle acceleration mechanisms and the high energy photon emission mechanisms are poorly understood phenomena. These mechanisms can be understood either by studying individual sources in detail or, alternatively, using the collective properties of a sample of sources. Recent development of GeV survey instruments, such as Fermi-LAT, and TeV survey instruments, such as Milagro, provides a large sample of high energy gamma-ray flux measurements from galactic and extra-galactic sources. In this thesis I provide constraints on GeV and TeV radiation mechanisms using the X-ray-TeV correlations and GeV-TeV correlations. My data sample was obtained from three targeted searches for extragalactic sources and two targeted search for galactic sources, using the existing Milagro sky maps. The first extragalactic candidate list consists of Fermi-LAT GeV extragalactic sources, and the second extragalactic candidate list consists of TeVCat extragalactic sources that have been detected by Imaging Atmospheric Cerenkov Telescopes (IACTs). In both extragalactic candidate lists Markarian 421 was the only source detected by Milagro. A comparison between the Markarian 421 time-averaged flux, measured by Milagro, and the flux measurements of transient states, measured by IACTs, is discussed. The third extragalactic candidate list is a list of potential TeV emitting BL Lac candidates that was synthesized using X-ray observations of BL Lac objects and a Synchrotron Self-Compton model. Milagro's sensitivity was not sufficient to detect any of those candidates. However, the 95% confidence flux upper limits of those sources were above the predicted flux. Therefore, these results provide evidence to conclude that the Synchrotron Self-Compton model for BL Lac objects is still a viable

  3. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  4. Psychometric properties of the Dutch version of the Hospital-level Consumer Assessment of Health Plans Survey instrument.

    OpenAIRE

    Arah, Onyebuchi A; Asbroek, A H A ten; Delnoij, Diana M J; de Koning, Johan S; Stam, Piet J A; Poll, Aldien H; Vriens, Barbara; Schmidt, Paul F; Klazinga, Niek S

    2006-01-01

    Objectives: To assess the reliability and validity of a translated version of the American Hospital-level Consumer Assessment of Health Plans Survey® (H-CAHPS) instrument for use in Dutch health care. Data Sources/Study Setting: Primary survey data from adults aged 18 years or more who were recently discharged from two multispecialty city hospitals in the Netherlands. Study Design: We used forward and backward translation procedures and a panel of experts to adapt the 66-item pilot H-CAHPS in...

  5. The School Counselor Leadership Survey: Instrument Development and Exploratory Factor Analysis

    Science.gov (United States)

    Young, Anita; Bryan, Julia

    2015-01-01

    This study examined the factor structure of the School Counselor Leadership Survey (SCLS). Survey development was a threefold process that resulted in a 39-item survey of 801 school counselors and school counselor supervisors. The exploratory factor analysis indicated a five-factor structure that revealed five key dimensions of school counselor…

  6. Temperature performance of portable radiation survey instruments used for environmental monitoring and clean-up activities in Fukushima

    Science.gov (United States)

    Saegusa, Jun; Yanagisawa, Kayo; Hasumi, Atsushi; Shimizu, Takenori; Uchita, Yoshiaki

    2017-08-01

    Following the Fukushima Dai-ichi Nuclear Power Plant accident in March 2011, extensive radiation monitoring and environmental clean-up activities have been conducted throughout the Fukushima region. Outside air temperatures there reach 40 °C in summer and -20 °C in winter, which are beyond the quoted operational range of many radiation survey instruments. Herein, temperature performance of four types of portable Japanese radiation survey instruments widely used in Fukushima was experimentally investigated using a temperature-controlled chamber. They included two ionization chamber type instruments, Fuji NHA1 and Aloka ICS-323C, and two NaI(Tl) scintillation type ones, Fuji NHC7 and Aloka TCS-172B. Experimental results showed significantly diverse characteristics on the temperature dependences from one type of instrument to another. For example, NHA1 overestimated the ambient dose-equivalent rate by as much as 17% at -30 °C and 10% at 40 °C, whereas the TCS-172B readings underestimated the rate by 30% at -30 °C and 7% at 40 °C.

  7. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  8. Can We Improve the Measurement of Attitudes towards the Welfare State? A Constructive Critique of Survey Instruments with Evidence from Focus Groups

    Science.gov (United States)

    Goerres, Achim; Prinzen, Katrin

    2012-01-01

    There is a large and growing literature on welfare state attitudes, most of which is built on random-sample population surveys with standardised closed-question items. This article criticises the existing survey instruments, especially those that are used within the International Social Survey Programme, in a novel approach with focus group data…

  9. Focus determination for the James Webb Space Telescope Science Instruments: A Survey of Methods

    Science.gov (United States)

    Davila, Pamela S.; Bolcar, Matthew R.; Boss, B.; Dean, B.; Hapogian, J.; Howard, J.; Unger, B.; Wilson, M.

    2006-01-01

    The James Webb Space Telescope (JWST) is a segmented deployable telescope that will require on-orbit alignment using the Near Infrared Camera as a wavefront sensor. The telescope will be aligned by adjusting seven degrees of freedom on each of 18 primary mirror segments and five degrees of freedom on the secondary mirror to optimize the performance of the telescope and camera at a wavelength of 2 microns. With the completion of these adjustments, the telescope focus is set and the optical performance of each of the other science instruments should then be optimal without making further telescope focus adjustments for each individual instrument. This alignment approach requires confocality of the instruments after integration and alignment to the composite metering structure, which will be verified during instrument level testing at Goddard Space Flight Center with a telescope optical simulator. In this paper, we present the results from a study of several analytical approaches to determine the focus for each instrument. The goal of the study is to compare the accuracies obtained for each method, and to select the most feasible for use during optical testing.

  10. A Survey on NiTi Rotary Instruments Usage by Endodontists and General Dentist in Tehran.

    Science.gov (United States)

    Mozayeni, Mohammad Ali; Golshah, Amin; Nik Kerdar, Nafiseh

    2011-01-01

    The aim of this study was to assess the extent of adoption, application and the associated issues with the nickel-titanium (NiTi) rotary instruments and techniques amongst endodontists and general dentists in Tehran. A total of 33 questions classified in six categories of demographics, frequency rate of NiTi rotary instrumentation and information. The sample size comprised of 100 endodontists and 100 general dental practitioners in Tehran. The overall response rate was 73.5%. NiTi rotary instruments were used by 98.4% and 50.6% of endodontists and general dentists, respectively. The main mentioned reason for not using rotary NiTi instruments was "lack of education". Among all procedural faults with NiTi, the most prevalent was "intra-canal file fracture" (88.5%) followed by "apical transportation" (71.2%) and "ledging" (68.3%). The main factors associated with the first procedural accident were "over-use" and "excessive pressure". Dentists need more training and more comprehensive education regarding NiTi rotary instruments and techniques.

  11. Assessing the Learning Environment for Medical Students: An Evaluation of a Novel Survey Instrument in Four Medical Schools.

    Science.gov (United States)

    Pololi, Linda H; Evans, Arthur T; Nickell, Leslie; Reboli, Annette C; Coplit, Lisa D; Stuber, Margaret L; Vasiliou, Vasilia; Civian, Janet T; Brennan, Robert T

    2017-06-01

    A practical, reliable, and valid instrument is needed to measure the impact of the learning environment on medical students' well-being and educational experience and to meet medical school accreditation requirements. From 2012 to 2015, medical students were surveyed at the end of their first, second, and third year of studies at four medical schools. The survey assessed students' perceptions of the following nine dimensions of the school culture: vitality, self-efficacy, institutional support, relationships/inclusion, values alignment, ethical/moral distress, work-life integration, gender equity, and ethnic minority equity. The internal reliability of each of the nine dimensions was measured. Construct validity was evaluated by assessing relationships predicted by our conceptual model and prior research. Assessment was made of whether the measurements were sensitive to differences over time and across institutions. Six hundred and eighty-six students completed the survey (49 % women; 9 % underrepresented minorities), with a response rate of 89 % (range over the student cohorts 72-100 %). Internal consistency of each dimension was high (Cronbach's α 0.71-0.86). The instrument was able to detect significant differences in the learning environment across institutions and over time. Construct validity was supported by demonstrating several relationships predicted by our conceptual model. The C-Change Medical Student Survey is a practical, reliable, and valid instrument for assessing the learning environment of medical students. Because it is sensitive to changes over time and differences across institution, results could potentially be used to facilitate and monitor improvements in the learning environment of medical students.

  12. The Mathematics Attitudes and Perceptions Survey: an instrument to assess expert-like views and dispositions among undergraduate mathematics students

    Science.gov (United States)

    Code, Warren; Merchant, Sandra; Maciejewski, Wes; Thomas, Matthew; Lo, Joseph

    2016-08-01

    One goal of an undergraduate education in mathematics is to help students develop a productive disposition towards mathematics. A way of conceiving of this is as helping mathematical novices transition to more expert-like perceptions of mathematics. This conceptualization creates a need for a way to characterize students' perceptions of mathematics in authentic educational settings. This article presents a survey, the Mathematics Attitudes and Perceptions Survey (MAPS), designed to address this need. We present the development of the MAPS instrument and its validation on a large (N = 3411) set of student data. Results from various MAPS implementations corroborate results from analogous instruments in other STEM disciplines. We present these results and highlight some in particular: MAPS scores correlate with course grades; students tend to move away from expert-like orientations over a semester or year of taking a mathematics course; and interactive-engagement type lectures have less of a negative impact, but no positive impact, on students' overall orientations than traditional lecturing. We include the MAPS instrument in this article and suggest ways in which it may deepen our understanding of undergraduate mathematics education.

  13. Nearest Neighbor Averaging and its Effect on the Critical Level and Minimum Detectable Concentration for Scanning Radiological Survey Instruments that Perform Facility Release Surveys.

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, Sean Donovan; Beall, Patrick S; Miller, Mark L

    2014-08-01

    Through the SNL New Mexico Small Business Assistance (NMSBA) program, several Sandia engineers worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (L c ) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the L c and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrument on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the L c and MDC) for high-density data maps that are obtained by scanning radiological survey instruments.

  14. Development of a survey instrument to investigate the primary care factors related to differences in cancer diagnosis between international jurisdictions.

    Science.gov (United States)

    Rose, Peter W; Hamilton, Willie; Aldersey, Kate; Barisic, Andriana; Dawes, Martin; Foot, Catherine; Grunfeld, Eva; Hart, Nigel; Neal, Richard D; Pirotta, Marie; Sisler, Jeffrey; Thulesius, Hans; Vedsted, Peter; Young, Jane; Rubin, Greg

    2014-06-17

    Survival rates following a diagnosis of cancer vary between countries. The International Cancer Benchmarking Partnership (ICBP), a collaboration between six countries with primary care led health services, was set up in 2009 to investigate the causes of these differences. Module 3 of this collaboration hypothesised that an association exists between the readiness of primary care physicians (PCP) to investigate for cancer - the 'threshold' risk level at which they investigate or refer to a specialist for consideration of possible cancer - and survival for that cancer (lung, colorectal and ovarian). We describe the development of an international survey instrument to test this hypothesis. The work was led by an academic steering group in England. They agreed that an online survey was the most pragmatic way of identifying differences between the jurisdictions. Research questions were identified through clinical experience and expert knowledge of the relevant literature.A survey comprising a set of direct questions and five clinical scenarios was developed to investigate the hypothesis. The survey content was discussed and refined concurrently and repeatedly with international partners. The survey was validated using an iterative process in England. Following validation the survey was adapted to be relevant to the health systems operating in other jurisdictions and translated into Danish, Norwegian and Swedish, and into Canadian and Australian English. This work has produced a survey with face, content and cross cultural validity that will be circulated in all six countries. It could also form a benchmark for similar surveys in countries with similar health care systems. The vignettes could also be used as educational resources. This study is likely to impact on healthcare policy and practice in participating countries.

  15. A systematic survey instrument translation process for multi-country, comparative health workforce studies

    NARCIS (Netherlands)

    Squires, A.; Aiken, L.H.; Heede, K. Van den; Sermeus, W.; Bruyneel, L.; Lindqvist, R.; Schoonhoven, L.; Stromseng, I.; Busse, R.; Brzostek, T.; Ensio, A.; Moreno-Casbas, M.; Rafferty, A.M.; Schubert, M.; Zikos, D.; Matthews, A.

    2013-01-01

    BACKGROUND: As health services research (HSR) expands across the globe, researchers will adopt health services and health worker evaluation instruments developed in one country for use in another. This paper explores the cross-cultural methodological challenges involved in translating HSR in the

  16. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review

    Science.gov (United States)

    2018-01-11

    Background: This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. Methods: A systematic review study design wa...

  17. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  18. The market for process control instrumentation in France. Foreign market survey report

    International Nuclear Information System (INIS)

    1977-04-01

    The market research was undertaken to study the present and potential US share of the market in France for process control instrumentation; to examine growth trends in French end-user industries over the next few years; to identify specific product categories that offer the most promising export potential for US companies; and to provide basic data which will assist US suppliers in determining current and potential sales and marketing opportunities. The trade promotional and marketing techniques were also reviewed

  19. Survey Instrument Development for Consumer Perception Testing to RTE Product in Convenience Store

    Directory of Open Access Journals (Sweden)

    Dyah Lestari Widaningrum

    2015-09-01

    Full Text Available Global trade and the abolition of trade barriers lead to the proliferation of imported food products such as various types of fast food products (RTE: ready-to-eat food sold by convenience stores mainly scattered in Jakarta. The question is what causes consumers choose certain convenience store to buy RTE Product and not choose another outlet category. To understand consumer perceptions, it is necessary to develop an instrument for measuring consumer perceptions of the option to purchase RTE Product at convenience stores. Variables used in this research are the perception and knowledge of the public/consumers against food safety, store attributes, service, and product attributes. The instrument used in this study is a questionnaire with a scalemeasuring1-5 to see the relationship between variables, we used the method of Structural Equation Modeling (SEM. The sample used in this study was 223 respondents that were divided into five areas in Jakarta, namely Central Jakarta, West Jakarta, South Jakarta, East Jakarta, and North Jakarta. The final outcome of the instrument development process was 25 observed variables, consisting of 4 indicators, which valid and reliable, with T-values for each observed variable is above 2,58, and Construct Reliability values range between 0,76 to 0,853.

  20. National Beef Quality Audit - 2016: Survey of carcass characteristics through instrument grading assessments.

    Science.gov (United States)

    Boykin, C A; Eastwood, L C; Harris, M K; Hale, D S; Kerth, C R; Griffin, D B; Arnold, A N; Hasty, J D; Belk, K E; Woerner, D R; Delmore, R J; Martin, J N; VanOverbeke, D L; Mafi, G G; Pfeiffer, M M; Lawrence, T E; McEvers, T J; Schmidt, T B; Maddock, R J; Johnson, D D; Carr, C C; Scheffler, J M; Pringle, T D; Stelzleni, A M; Gottlieb, J; Savell, J W

    2017-07-01

    The instrument grading assessment portion of the National Beef Quality Audit (NBQA) - 2016 allows the unique opportunity to evaluate beef carcass traits over the course of a year. One week of instrument grading data was collected each month from 5 beef processing corporations encompassing 18 facilities from January 2016 through December 2016 ( = 4,544,635 carcasses). Mean USDA yield grade (YG) was 3.1 with 1.37 cm fat thickness (FT), 88.9 cm LM area, 393.6 kg HCW, and 2.1% KPH. Frequency distribution of USDA YG was 9.5% YG 1, 34.6% YG 2, 38.8% YG 3, 14.6% YG 4, and 2.5% YG 5. Increases in HCW and FT since the NBQA-2011 were major contributors to differences in mean YG and the (numerically) increased frequency of YG 3, 4, and 5 carcasses found in the current audit. Mean marbling score was Small, and the distribution of USDA quality grades was 4.2% Prime, 71.4% Choice, 21.7% Select, and 2.7% other. Frequency of carcasses grading Prime on Monday (6.43%) was numerically higher than the average frequency of carcasses grading Prime overall (4.2%). Monthly HCW means were 397.6 kg in January, 397.2 kg in February, 396.5 kg in March, 389.3 kg in April, 384.8 kg in May, 385.0 kg in June, 386.1 kg in July, 394.1 kg in August, 399.1 kg in September, 403.9 kg in October, 406.5 kg in November, and 401.9 kg in December. Monthly mean marbling scores were Small in January, Small in February, Small in March, Small in April, Small in May, Small in June, Small in July, Small in August, Small in September, Small in October, Small in November, and Small in December. Both mean HCW and mean marbling score declined in the months of May and June. The month with the greatest numerical frequency of dark cutters was October (0.74%). Comparison of overall data from in-plant carcass and instrument grading assessments revealed close alignment of information, especially for YG (3.1 for in-plant assessment versus 3.1 for instrument grading) and marbling (Small for in-plant assessment versus Small

  1. Towards the development of an outcome instrument for spinal trauma : An international survey of spinal surgeons

    NARCIS (Netherlands)

    Oner, F. Cumhur; Sadiqi, Said; Lehr, A. Mechteld; Dvorak, Marcel F.; Aarabi, Bizhan; Chapman, Jens R.; Fehlings, Michael G.; Kandziora, Frank; Rajasekaran, S.; Vaccaro, Alexander R.

    2015-01-01

    STUDY DESIGN.: International web-based survey. OBJECTIVE.: To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. SUMMARY OF BACKGROUND DATA.: There is no universally accepted

  2. Proposing a survey instrument for measuring operational, formal, information and strategic Internet skills

    NARCIS (Netherlands)

    van Deursen, Alexander Johannes Aloysius Maria; van Dijk, Johannes A.G.M.; Peters, O.

    2012-01-01

    Observational studies prove to be very suitable to provide a realistic view of people's Internet skills. However, their cost and time are a strong limitation for large-scale data gathering. A useful addition to the measurement of Internet skills would be the development of survey questions for

  3. New instrument for measuring student beliefs about physics and learning physics: The Colorado Learning Attitudes about Science Survey

    Science.gov (United States)

    Adams, W. K.; Perkins, K. K.; Podolefsky, N. S.; Dubson, M.; Finkelstein, N. D.; Wieman, C. E.

    2006-06-01

    The Colorado Learning Attitudes about Science Survey (CLASS) is a new instrument designed to measure student beliefs about physics and about learning physics. This instrument extends previous work by probing additional aspects of student beliefs and by using wording suitable for students in a wide variety of physics courses. The CLASS has been validated using interviews, reliability studies, and extensive statistical analyses of responses from over 5000 students. In addition, a new methodology for determining useful and statistically robust categories of student beliefs has been developed. This paper serves as the foundation for an extensive study of how student beliefs impact and are impacted by their educational experiences. For example, this survey measures the following: that most teaching practices cause substantial drops in student scores; that a student’s likelihood of becoming a physics major correlates with their “Personal Interest” score; and that, for a majority of student populations, women’s scores in some categories, including “Personal Interest” and “Real World Connections,” are significantly different from men’s scores.

  4. Development and validation of a survey instrument to measure factors that influence pharmacist adoption of prescribing in Alberta, Canada.

    Science.gov (United States)

    Guirguis, Lisa M; Hughes, Christine A; Makowsky, Mark J; Sadowski, Cheryl A; Schindel, Theresa J; Yuksel, Nese; Faruquee, Chowdhury F

    2018-01-01

    reliability while the remaining six scales had strong evidence for reliability and validity. Through a multi-stage process, a survey instrument was developed to capture pharmacists' perceptions of prescribing influences. This questionnaire may support future research to develop interventions to enhance adoption of prescribing and enhance direct patient care by pharmacists.

  5. Instrumentation for surveying the lower part of the atmosphere in extremes conditions

    Science.gov (United States)

    Gobinddass, Marie-Line; Molinie, Jack; Richard, Sandrine; Jean-Louis, Sabrina

    To observe atmospheric phenomena such as clouds, precipitation and wind in order to understand how they form and evolve meteorologists use few instruments which allows to measure parameters as temperature, pressure and humidity. In the specific case of Kourou region where the French Space Agency is located the environment and safeguard group works on protecting biodiversity in and around the center. By considering a few scientific challenges in atmospheric science one of the main topics of this work consists on the understanding of the fluctuation of the atmosphere due to natural or industrials perturbations. We have considered a few experiences with many instruments in a large space of more than 1200 km per square. To differentiate and try to quantify industrial cloud from natural cloud or from natural atmosphere, the idea of using a drone has been experimented. The ratio of the cost of such experimentation with the relevance of the results which can be obtained will be discussed here. It is necessary to take into account the turbulence in the atmosphere due to industrial acid cloud or hot cloud. Finally, instead of taking the risk of having airbone measurements with a pilot we have thought of the tetherball due to it lower cost and for security reason. The technical experiment and few type of results will be presented here.

  6. Measuring stigma among abortion providers: assessing the Abortion Provider Stigma Survey instrument.

    Science.gov (United States)

    Martin, Lisa A; Debbink, Michelle; Hassinger, Jane; Youatt, Emily; Eagen-Torkko, Meghan; Harris, Lisa H

    2014-01-01

    We explored the psychometric properties of 15 survey questions that assessed abortion providers' perceptions of stigma and its impact on providers' professional and personal lives referred to as the Abortion Provider Stigma Survey (APSS). We administered the survey to a sample of abortion providers recruited for the Providers' Share Workshop (N = 55). We then completed analyses using Stata SE/12.0. Exploratory factor analysis, which resulted in 13 retained items and identified three subscales: disclosure management, resistance and resilience, and discrimination. Stigma was salient in abortion provider's lives: they identified difficulties surrounding disclosure (66%) and felt unappreciated by society (89%). Simultaneously, workers felt they made a positive contribution to society (92%) and took pride in their work (98%). Paired t-test analyses of the pre- and post-Workshop APSS scores showed no changes in the total score. However, the Disclosure Management subscale scores were significantly lower (indicating decreased stigma) for two subgroups of participants: those over the age of 30 and those with children. This analysis is a promising first step in the development of a quantitative tool for capturing abortion providers' experiences of and responses to pervasive abortion stigma.

  7. Report of the Survey on the Design Review of New Reactor Applications. Volume 1 - Instrumentation and Control

    International Nuclear Information System (INIS)

    Downey, Steven

    2014-06-01

    At the tenth meeting of the CNRA Working Group on the Regulation of New Reactors (WGRNR) in March 2013, the members agreed to present the responses to the Second Phase, or Design Phase, of the Licensing Process Survey as a multi-volume text. As such, each report will focus on one of the eleven general technical categories covered in the survey. The general technical categories were selected to conform to the topics covered in the International Atomic Energy Agency (IAEA) Safety Guide GS-G-4.1. This report, which is the first volume, provides a discussion of the survey responses related to Instrumentation and Control (I and C). The Instrumentation and Control category includes the twelve following technical topics: Reactor trip system, actuation systems for Engineered Safety Features (ESF), safe shutdown system, safety-related display instrumentation, information and interlock systems important to safety, controls systems, main control room, supplementary control room, diverse I and C systems, data communication systems, software reliability and cyber-security. For each technical topic, the member countries described the information provided by the applicant, the scope and level of detail of the technical review, the technical basis for granting regulatory authorisation, the skill sets required and the Level of effort needed to perform the review. Based on a comparison of the information provided in response to the survey, the following observations were made: - Among the regulatory organisations that responded to the survey, there are similarities in the design information provided by an applicant. In most countries, the design information provided by an applicant includes, but is not limited to, a description of the I and C system design and functions, a description of the verification and validation programmes, and provisions for analysis, testing, and inspection of various I and C systems. - In addition to the regulations, it is a common practice for countries

  8. Measuring patient trust in telemedicine services: Development of a survey instrument and its validation for an anticoagulation web-service.

    Science.gov (United States)

    Velsen, Lex van; Tabak, Monique; Hermens, Hermie

    2017-01-01

    For many eServices, end-user trust is a crucial prerequisite for use. For the telemedicine context however, knowledge about the coming about and measurement of end-user trust is scarce. To develop and validate the PAtient Trust Assessment Tool (PATAT): a survey instrument to quantitatively assess patient trust in a telemedicine service. Informed by focus groups, we developed a survey that includes measurement scales for the following factors: trust in the care organization, care professional, treatment, and technology, as well as a scale that assesses a holistic view on trust in the telemedicine service. The survey was completed by 795 patients that use a telemedicine application to manage their anticoagulation treatment. Data were analyzed by means of Partial Least Squares Structural Equation Modeling (PLS-SEM). The measurement model yielded good to excellent quality measures, after the removal of one item. The causal model resulted in high explained variance (R 2 =0.68). Trust in healthcare professionals and the treatment had a small effect on overall trust, while trust in the technology displayed a large effect. Trust in the care organization did not result in a significant effect on overall trust. The PATAT is a valid means to assess patient trust in a telemedicine service and can be used to benchmark such a service or to elicit redesign input. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Customizing survey instruments and data collection to reach Hispanic/Latino adults in border communities in Texas.

    Science.gov (United States)

    O'Hegarty, Michelle; Pederson, Linda L; Thorne, Stacy L; Caraballo, Ralph S; Evans, Brian; Athey, Leslie; McMichael, Joseph

    2010-04-01

    We sought to modify an instrument and to use it to collect information on smoking knowledge, attitudes, beliefs, and behaviors among Hispanics/Latinos, and to adapt survey methods to obtain high participation levels. Methods. Promotoras (outreach workers) conducted face-to-face interviews with 1485 Hispanic adults (July 2007-April 2008). The project team used GeoFrame field enumeration methods to develop a sampling frame from households in randomly selected colonias (residential areas along the Texas-Mexico border that may lack some basic necessities (e.g. portable water), in El Paso, Texas. The revised questionnaire included 36 unchanged items from the State Adult Tobacco Survey, 7 modified items, and 17 new items focusing on possible culturally specific quitting methods, secondhand smoke issues, and attitudes and knowledge about tobacco use that might be unique for Hispanic/Latino groups. The eligibility rate was 90.2%, and the conservative combined completed screener and interview response rate was 80.0%. Strategic, targeted, carefully designed methods and surveys can achieve high reach and response rates in hard-to-reach populations. Similar procedures could be used to obtain cooperation of groups who may not be accessible with traditional methods.

  10. ARABIC TRANSLATION AND ADAPTATION OF THE HOSPITAL CONSUMER ASSESSMENT OF HEALTHCARE PROVIDERS AND SYSTEMS (HCAHPS) PATIENT SATISFACTION SURVEY INSTRUMENT.

    Science.gov (United States)

    Dockins, James; Abuzahrieh, Ramzi; Stack, Martin

    2015-01-01

    To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.

  11. Instrument specifications and geophysical records for airborne electromagnetic survey of parts of Iron, Baraga, and Dickson Counties, Michigan

    Science.gov (United States)

    Heran, William D.; Smith, Bruce D.

    1980-01-01

    The data presented herein is from an airborne electromagnetic INPUT* survey conducted by Geoterrex Limited of Canada for the U.S. Geological Survey. The survey area is located in the central part of the Upper Peninsula of Michigan, within parts of Iron, Baraga, and Dickinson Counties. The general area covered is between 46°00' and 46°30' latitude and 88°00' and 88°30' longitude (fig. 1).The INPUT survey was flown as part of a U.S. Geological Survey CUSMAP (Conterminous United States Mineral Appraisal Program) project focusing on the Iron River 2° quadrangle. The survey was flown in order to provide geophysical information which will aid in an integrated geological assessment of mineral potentials of this part of the Iron River 2° quadrangle. The flight line spacing was chosen to maximize the areal coverage without a loss of resolution of major lithologic and structural features.East-west flight lines were flown 400 feet above ground at 1/2 mile intervals. Aerial photos were used for navigation, and the flight path was recorded on continuous-strip film. A continuously recording total field ground magnetic station was used to monitor variations in the Earth's magnetic field. One north-south line was flown to provide a tie for the magnetic data, which was recorded simultaneously with the electromagnetic data by a sensor mounted in the tail of the aircraft. This report is one of two open-file reports. The map in the other report Heran and Smith (1980) shows locations of the fiducial points, the flight lines, preliminary locations of anomalies and conductive zones; all plotted on an air photomosaic. The latitude and longitude ticks marked on this map are only approximate due to distortion in air photos used to recover the flight line position. This map is preliminary and is not to be considered a final interpretation. The present report contains a description of the instrument specifications, a copy of the ground station magnetic data, and a record of the

  12. Chinese version of the Global Youth Tobacco Survey: cross-cultural instrument adaptation

    Directory of Open Access Journals (Sweden)

    Chiou Hung-Yi

    2008-04-01

    Full Text Available Abstract Background Tobacco smoking poses public health concerns because of its high risk for many chronic diseases. Most smokers begin using tobacco in their teens and recent reports indicate that smoking prevalence is climbing among youth. The Global Youth Tobacco Survey (GYTS is a worldwide, school-based, tobacco-specific survey, but cross-cultural differences limit its effectiveness in international studies. Specifically, the GYTS assesses not only the prevalence of smoking, but also tobacco-related attitudes, school curricula, and advertisements, which are culturally influenced. Therefore, we conducted this study to develop a Chinese version of the GYTS for both national surveillance and international comparison. Methods The original English GYTS was translated and back translated using a cross-cultural adaptation process. The comprehensiveness and feasibility of using the Chinese-version GYTS were reviewed by a panel of 6 tobacco-control experts. The understandability and cultural relevance of the Chinese-version GYTS were discussed in a focus group of 5 schoolteachers and 8 students. The expert and focus group feedback was incorporated into a final Chinese version of the GYTS, which was administered to 382 students throughout Taiwan by multi-stage sampling from 10 randomly selected schools. Results The internal consistency (Cronbach's alpha for the GYTS subscales (smoking susceptibility, attitude toward smoking, and media messages about smoking ranged from 0.70 to 0.94. The internal logical agreement of responses ranged from 85.3 to 99.2%. Conclusion The Chinese version of the GYTS has good reliability and validity and can serve as the foundation for international comparison and tobacco control in Chinese-speaking communities.

  13. Tomographic intensity mapping versus galaxy surveys: observing the Universe in H α emission with new generation instruments

    Science.gov (United States)

    Silva, B. Marta; Zaroubi, Saleem; Kooistra, Robin; Cooray, Asantha

    2018-04-01

    The H α line emission is an important probe for a number of fundamental quantities in galaxies, including their number density, star formation rate (SFR), and overall gas content. A new generation of low-resolution intensity mapping (IM) probes, e.g. SPHEREx and CDIM, will observe galaxies in H α emission over a large fraction of the sky from the local Universe till a redshift of z ˜ 6 - 10, respectively. This will also be the target line for observations by the high-resolution Euclid and WFIRST instruments in the z ˜ 0.7-2 redshift range. In this paper, we estimate the intensity and power spectra of the H α line in the z ˜ 0-5 redshift range using observed line luminosity functions (LFs), when possible, and simulations, otherwise. We estimate the significance of our predictions by accounting for the modelling uncertainties (e.g. SFR, extinction, etc.) and observational contamination. We find that IM surveys can make a statistical detection of the full H α emission between z ˜ 0.8 and 5. Moreover, we find that the high-frequency resolution and the sensitivity of the planned CDIM surveys allow for the separation of H α emission from several interloping lines. We explore ways to use the combination of these line intensities to probe galaxy properties. As expected, our study indicates that galaxy surveys will only detect bright galaxies that contribute up to a few per cent of the overall H α intensity. However, these surveys will provide important constraints on the high end of the H α LF and put strong constraints on the active galactic nucleus LF.

  14. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,

  15. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care

    Science.gov (United States)

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables—training, self-efficacy, system quality and information quality—on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time. PMID:29315323

  16. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care.

    Science.gov (United States)

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables-training, self-efficacy, system quality and information quality-on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time.

  17. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    Science.gov (United States)

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  18. Development and validation of a cross-cultural knowledge, attitudes, and practices survey instrument for chronic kidney disease in a Swahili-speaking population.

    Science.gov (United States)

    Stanifer, John W; Karia, Francis; Voils, Corrine I; Turner, Elizabeth L; Maro, Venance; Shimbi, Dionis; Kilawe, Humphrey; Lazaro, Matayo; Patel, Uptal D

    2015-01-01

    Non-communicable diseases are a growing global burden, and structured surveys can identify critical gaps to address this epidemic. In sub-Saharan Africa, there are very few well-tested survey instruments measuring population attributes related to non-communicable diseases. To meet this need, we have developed and validated the first instrument evaluating knowledge, attitudes and practices pertaining to chronic kidney disease in a Swahili-speaking population. Between December 2013 and June 2014, we conducted a four-stage, mixed-methods study among adults from the general population of northern Tanzania. In stage 1, the survey instrument was constructed in English by a group of cross-cultural experts from multiple disciplines and through content analysis of focus group discussions to ensure local significance. Following translation, in stage 2, we piloted the survey through cognitive and structured interviews, and in stage 3, in order to obtain initial evidence of reliability and construct validity, we recruited and then administered the instrument to a random sample of 606 adults. In stage 4, we conducted analyses to establish test-retest reliability and known-groups validity which was informed by thematic analysis of the qualitative data in stages 1 and 2. The final version consisted of 25 items divided into three conceptual domains: knowledge, attitudes and practices. Each item demonstrated excellent test-retest reliability with established content and construct validity. We have developed a reliable and valid cross-cultural survey instrument designed to measure knowledge, attitudes and practices of chronic kidney disease in a Swahili-speaking population of Northern Tanzania. This instrument may be valuable for addressing gaps in non-communicable diseases care by understanding preferences regarding healthcare, formulating educational initiatives, and directing development of chronic disease management programs that incorporate chronic kidney disease across sub

  19. A Frailty Instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE

    Directory of Open Access Journals (Sweden)

    Romero-Ortuno Roman

    2010-08-01

    Full Text Available Abstract Background A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http://www.share-project.org, a large population-based survey conducted in 2004-2005 in twelve European countries. Methods Subjects: SHARE Wave 1 respondents (17,304 females and 13,811 males. Measures: five SHARE variables approximating Fried's frailty definition. Analyses (for each gender: 1 estimation of a discreet factor (DFactor model based on the frailty variables using LatentGOLD®. A single DFactor with three ordered levels or latent classes (i.e. non-frail, pre-frail and frail was modelled; 2 the latent classes were characterised against a biopsychosocial range of Wave 1 variables; 3 the prospective mortality risk (unadjusted and age-adjusted for each frailty class was established on those subjects with known mortality status at Wave 2 (2007-2008 (11,384 females and 9,163 males; 4 two web-based calculators were created for easy retrieval of a subject's frailty class given any five measurements. Results Females: the DFactor model included 15,578 cases (standard R2 = 0.61. All five frailty indicators discriminated well (p N = 10,420; 66.9%, pre-frail (N = 4,025; 25.8%, and frail (N = 1,133; 7.3%. Relative to the non-frail class, the age-adjusted Odds Ratio (with 95% Confidence Interval for mortality at Wave 2 was 2.1 (1.4 - 3.0 in the pre-frail and 4.8 (3.1 - 7.4 in the frail. Males: 12,783 cases (standard R2 = 0.61, all frailty indicators had p N = 10,517; 82.3%, pre-frail (N = 1,871; 14.6%, and frail (N = 395; 3.1%; age-adjusted OR (95% CI for mortality: 3.0 (2.3 - 4.0 in the pre-frail, 6.9 (4.7 - 10.2 in the frail. Conclusions The SHARE Frailty Instrument has sufficient construct and

  20. The Development of a Small-Scale Survey Instrument of UK Teachers to Study Professional Use (and Non-Use) of and Attitudes to Social Media

    Science.gov (United States)

    Owen, Nathaniel; Fox, Alison; Bird, Terese

    2016-01-01

    This paper documents the creation, implementation and analysis of a survey instrument designed to reveal patterns of use and attitudes towards the value of social media by UK teachers. The study was motivated to discover which teachers use social media professionally, how they use it (both personally and professionally) and attitudes to social…

  1. Development of a survey instrument to assess health-related quality of life in small animal cancer patients treated with chemotherapy.

    Science.gov (United States)

    Iliopoulou, Maria A; Kitchell, Barbara E; Yuzbasiyan-Gurkan, Vilma

    2013-06-15

    To develop a quality of life (QOL) survey for use in a canine cancer chemotherapy setting, validate the instrument's utility, identify key questions that facilitate client and clinician communication regarding decisions in patient care, and use human and veterinary QOL literature to develop a comprehensive yet simple proxy survey instrument. Survey. 29 canine chemotherapy patients. Patients were evaluated by both owners and veterinarians at the time of initial visit to the clinic and at 3 and 6 weeks after the initiation of chemotherapy. This survey consisted of a longitudinal evaluation of QOL with 6 components addressing the animal's QOL retrospectively, before onset of cancer; changes in the animal's QOL since manifestation of disease; changes in the animal's QOL with regard to treatment response; owner's QOL and its impact on priorities in decision making; clinician's impression of the owner's priorities and QOL; and clinician's impression of the dog's QOL. Multiple regression analysis indicated 3 significant predictors of canine cancer patient QOL to be play behaviors, signs of illness, and canine happiness as perceived by owners. The QOL instrument was easy to use and enhanced client perception of patient care and clinician concern. Owners enjoyed the opportunity to complete the survey. Since questions regarding play behaviors, clinical signs of disease, and canine happiness were significant indicators of changes in QOL, these should be included in future studies. Quality of life assessment may facilitate treatment decisions and assessment of canine patients undergoing chemotherapy.

  2. On-line instrument for control of water and steam quality at energy production plants - a market survey

    International Nuclear Information System (INIS)

    Fahlgren, N.; Persson, F.

    1988-10-01

    Instruments for on-line measuring are today available for all water analyses that can be of intrerest in power stations. For some of the analyses instruments have been in operation for many years e.g. for determination of silica, sodium and oxygen. For other analyses no instruments or only a few have been in operation. Many instruments are developed under the last years. Operation experiences for many instruments are therefore limited. For mostly all instruments, also for instruments that have been in operation a long time, operation experiences from the same type of instruments differ from plant to plant. The reson is that most of the instruments need daily or weekly maintenance and that has not always been aquainted. The time for necessary maintenance is however not so long that it is deterrent. The time for necessary maintenance for an instrument is normally 1-2 hours a week. On-line measuring, improve supervision and reliability of service and are therefore to recommend in both big and small plants. In small plants it is very important to have a good supervision of pH-value, conductivity, harness and the content of oxygen in feed water. (authors)

  3. ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

    Science.gov (United States)

    Roder, H. M.

    1974-01-01

    Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

  4. Main surveying instruments used in environmental monitoring: a classic approach of the book Topografia Geral | Principais instrumentos topográficos utilizados no monitoramento ambiental : uma abordagem clássica do livro Topografia Geral

    Directory of Open Access Journals (Sweden)

    José Machado

    2016-05-01

    Full Text Available This paper addresses the main points inherent knowledge of surveying instruments today, as well as its evolution in history and goals. The work was carried out on the basis of Chapters I and II of the book Topografia Geral, which was held a didactic review for teaching students , teachers, researchers and surveying professionals. The book is a clear and concise language of the main elements that make up the surveying: instruments and accessories. Objective of this study was to make an approach on the main surveying instruments and accessories used in environmental monitoring.

  5. Evaluation of the two non-consecutive 24-h recall instrument for pan-European food consumption surveys

    NARCIS (Netherlands)

    Crispim, S.P.

    2011-01-01

    Background: The comparability of food consumption data originating from national nutritional surveys in Europe is currently hampered because of different methodologies used. Therefore, experts in the European Food Consumption Survey Method (EFCOSUM) consortium proposed to use two non-consecutive

  6. Research reactor instrumentation

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2001-02-01

    This is a textbook on research reactor instrumentation for training purposes, it gives a survey on research reactor instrumentation requirements and eight exercises covering the major aspects of this topic are presented. (author)

  7. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  8. Confidence to Perform in the Global Marketplace: Constructing and Validating a Survey Instrument for Community College Students.

    Science.gov (United States)

    Slantcheva-Durst, Snejana; Liu, Mingyang

    This article discusses the construction and validation of an instrument to gauge community college students' confidence to perform in the global marketplace. The instrument was designed to capture students' beliefs in their own abilities to successfully carry out job-related tasks in cross-cultural work environments that are globally-interconnected and constantly at flux. The instrument items emerged from a comprehensive review of literature, nationwide workforce skills initiatives, rounds of expert panel analyses, and focus groups. Items were formulated within Bandura's framework of self-efficacy, and the instrument was analyzed with Rasch measurement. The Rasch analysis, conducted on a sample of 741 students, provided evidence of the content validity of the items, the generalizability of the measure, and its external validity. The instrument can offer useful feedback to community college internationalization-focused staff in their efforts to assess outcomes of international initiatives for community college students, thus supporting program assessment, evaluation of student growth, and institutional decision-making.

  9. Factors influencing the provision of end-of-life care in critical care settings: development and testing of a survey instrument.

    Science.gov (United States)

    Ranse, Kristen; Yates, Patsy; Coyer, Fiona

    2015-03-01

    To develop and psychometrically test a survey instrument to identify the factors influencing the provision of end-of-life care by critical care nurses. Following a decision to withdraw life-sustaining treatment, critical care nurses remain with the patient and their family providing end-of-life care. Identification of factors influencing the provision of this care can give evidence to inform practice development and support nurses. A cross-sectional survey of critical care nurses. An online survey was developed, reviewed by an expert panel and pilot tested to obtain preliminary evidence of its reliability and validity. In May 2011, a convenience sample of critical care nurses (n = 392, response rate 25%) completed the survey. The analytical approach to data obtained from the 58 items measured on a Likert scale included exploratory factor analysis and descriptive statistics. Exploratory factor analysis identified eight factors influencing the provision of end-of-life care: emotional support for nurses, palliative values, patient and family preferences, resources, organizational support, care planning, knowledge and preparedness. Internal consistency of each latent construct was deemed satisfactory. The results of descriptive statistics revealed a strong commitment to the inclusion of families in end-of-life care and the value of this care in the critical care setting. This paper reports preliminary evidence of the psychometric properties of a new survey instrument. The findings may inform practice development opportunities to support critical care nurses in the provision of end-of-life care and improve the care that patients and their families receive. © 2014 John Wiley & Sons Ltd.

  10. The development and testing of a survey instrument for benchmarking dental plan performance: using insured patients' experiences as a gauge of dental care quality.

    Science.gov (United States)

    Keller, San; Col Martin, Gary C; Evensen, Christian T; Capt Mitton, Robert H

    2009-02-01

    There is no standard, nonproprietary method for providing national benchmarks of dental care quality as described by patients. The purpose of this research was to develop such a tool following guidelines of the Consumer Assessment of Healthcare Providers and Systems (CAHPS) initiative. The authors identified domains of dental care quality via qualitative methods, including a literature review, stakeholder interviews and focus groups with beneficiaries, and they cognitively tested draft questions with patients to yield a pilot survey. Psychometric analyses of pilot data (n = 3,264) identified summary indexes and guided survey revisions. The authors used two waves of subsequent data collection (n = 4,221) to test the validity of the revised survey. The mean response rate across three rounds of data collection was 51 percent. Statistical analysis indicated that 17 questions could be reliably collapsed into three composite measures: "Care From Dentist and Staff" (reliability = 0.89, scaling success = 100 percent); "Access to Dental Care" (reliability = 0.78, scaling success = 100 percent); and "Dental Plan Coverage/Service" (reliability = 0.84, scaling success = 100 percent). The validity of the survey was supported in mail and Internet modes for the American English language, and the instrument was approved by the CAHPS consortium for distribution as the CAHPS Dental Plan Survey. PRACTICE IMPLICATIONS. A tool is available now for assessing dental care quality by measuring adult patients' experiences with their dental care and coverage. The authors tested this instrument only in a population with third-party coverage, however, which is a potential limitation that should be considered.

  11. Fine-scale environmental effects on Cape hake survey catch rates in the Northern Benguela, using data from a trawl-mounted instrument package

    DEFF Research Database (Denmark)

    Kainge, Paulus Inekela; Wieland, Kai

    2017-01-01

    rates of both hake species, whereas solar zenith angle representing diel effects and surface layer chlorophyll appeared to be less important. The explained deviance for the best models ranged from 71.4% for M. capensis to 92.7% for M. paradoxus between 43 and 57 cm in length. Differences in catch rates...... hake trawl survey of 2016, and was made possible for the first time in Namibia by collecting oceanographic information with a trawl-mounted instrument package concurrently with the catch data. Depth, geographical position, bottom oxygen and bottom temperature had the most pronounced effect on the catch...... between species and size groups were most pronounced for bottom depth and bottom oxygen. The results show the potential value of trawl-mounted instrumental packages for the collection of reliable environmental data important in the study of environmental influence on abundance, catch rates...

  12. The balanced scorecard as a potential instrument for supporting planning and improvement in accounting education: Comparative survey findings

    Directory of Open Access Journals (Sweden)

    CJ Cronje

    2004-04-01

    Full Text Available This paper is firstly a comparison of the components of a potential balanced scorecard for accounting departments of universities in South Africa and Australia. Secondly, the various suggested measurement criteria of the balanced scorecard components are also compared. The findings of the research paper indicate no significant differences. The conclusion is that the balanced scorecard constitutes a potential instrument for supporting the planning and improvement of the accounting education environment.

  13. Development of a Survey Instrument to Measure TEFL Academics' Perceptions about, Individual and Workplace Characteristics for Conducting Research

    Science.gov (United States)

    Bai, Li; Hudson, Peter; Millwater, Jan; Tones, Megan

    2013-01-01

    A 30-item survey was devised to determine Chinese TEFL (Teaching English as a Foreign Language) academics' potential for conducting research. A five-part Likert scale was used to gather data from 182 academics on four factors: (1) perceptions on teaching-research nexus, (2) personal perspectives for conducting research, (3) predispositions for…

  14. Development and Validation of an Instrument for Assessing Climate Change Knowledge and Perceptions: The Climate Stewardship Survey (CSS)

    Science.gov (United States)

    Walker, Scott L.; McNeal, Karen S.

    2013-01-01

    The Climate Stewardship Survey (CSS) was developed to measure knowledge and perceptions of global climate change, while also considering information sources that respondents 'trust.' The CSS was drafted using a three-stage approach: development of salient scales, writing individual items, and field testing and analyses. Construct validity and…

  15. Relationships Among the Knowledge, Efficacy, and Practices Instrument, Color-Blind Racial Attitudes Scale, Deamonte Driver Survey, and Defining Issues Test 2.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cynthia W

    2016-03-01

    Concordance studies indicate the degree to which instruments measure the same or similar constructs or something different. The aims of this study were to identify the factor structure of the Deamonte Driver Survey and determine the relationship between the Deamonte Driver (a measure of social class stereotyping), the Defining Issues Test 2 (DIT2; a measure of ethical sensitivity), the Color-Blind Racial Attitudes Scale (CoBRAS; a measure of racial stereotyping), and the Knowledge, Efficacy, and Practices Instrument (KEPI; a measure of cultural competence). The results showed a three-factor solution for the Deamonte Driver Survey and significant relationships between CoBRAS and DIT2 subscales and between CoBRAS and Deamonte Driver subscales. Significant relationships between the measures and exploratory variables, underrepresented minority status, age, citizenship, marital status, political stance, English as a first language, and gender were found. The lack of a significant relationship between the KEPI and Deamonte Driver, DIT2, or CoBRAS subscales suggests that the KEPI is measuring a unique construct. These findings showed how these scales contributed to the assessment of cultural competence among dental students and faculty.

  16. An Assessment of the Effectiveness of Air Force Risk Management Practices in Program Acquisition Using Survey Instrument Analysis

    Science.gov (United States)

    2015-06-18

    System, 2014. Washington: OUSD (AT&L), June, 2014. Department of Defense. Risk Management Guide for DoD Acquisition, 6th Edition (Version 1.0...enough into the survey to begin answering questions on risk practices. All of the data statistical analysis will be performed using SPSS . Prior to...acceptable result (George and Mallery, 2003; Kline, 1999). In this case, SPSS returns a Cronbach’s Alpha of 0.936; well above the 0.7 standard

  17. A CIRCLELESS "2D/3D TOTAL STATION": A LOW COST INSTRUMENT FOR SURVEYING, RECORDING POINT CLOUDS, DOCUMENTATION, IMAGE ACQUISITION AND VISUALISATION

    Directory of Open Access Journals (Sweden)

    M. Scherer

    2013-07-01

    Full Text Available Hardware and software of the universally applicable instrument - referred to as a 2D/3D total station – are described here, as well as its practical use. At its core it consists of a 3D camera – often also called a ToF camera, a pmd camera or a RIM-camera – combined with a common industrial 2D camera. The cameras are rigidly coupled with their optical axes in parallel. A new type of instrument was created mounting this 2D/3D system on a tripod in a specific way. Because of it sharing certain characteristics with a total station and a tacheometer, respectively, the new device was called a 2D/3D total station. It may effectively replace a common total station or a laser scanner in some respects. After a brief overview of the prototype's features this paper then focuses on the methodological characteristics for practical application. Its usability as a universally applicable stand-alone instrument is demonstrated for surveying, recording RGB-coloured point clouds as well as delivering images for documentation and visualisation. Because of its limited range (10m without reflector and 150 m to reflector prisms and low range accuracy (ca. 2 cm to 3 cm compared to present-day total stations and laser scanners, the practical usage of the 2D/3D total station is currently limited to acquisition of accidents, forensic purpuses, speleology or facility management, as well as architectural recordings with low requirements regarding accuracy. However, the author is convinced that in the near future advancements in 3D camera technology will allow this type of comparatively low cost instrument to replace the total station as well as the laser scanner in an increasing number of areas.

  18. An Instrument to Measure Adherence to Weight Loss Programs: The Compliance Praxis Survey-Diet (COMPASS-Diet

    Directory of Open Access Journals (Sweden)

    Gabriela Böhm

    2013-09-01

    Full Text Available Adherence to behavioral weight loss strategies is important for weight loss success. We aimed to examine the reliability and validity of a newly developed compliance praxis-diet (COMPASS-diet survey with participants in a 10-week dietary intervention program. During the third of five sessions, participants of the “slim-without-diet” weight loss program (n = 253 completed the COMPASS-diet survey and provided data on demographic and clinical characteristics, and general self-efficacy. Group facilitators completed the COMPASS-diet-other scale estimating participants’ likely adherence from their perspective. We calculated internal consistency, convergent validity, and predictive value for objectively measured weight loss. Mean COMPASS-diet-self score was 82.4 (SD 14.2 and COMPASS-diet-other score 80.9 (SD 13.6 (possible range 12–108, with lowest scores in the normative behavior subscale. Cronbach alpha scores of the COMPASS-diet-self and -other scale were good (0.82 and 0.78, respectively. COMPASS-diet-self scores (r = 0.31 correlated more highly with general self-efficacy compared to COMPASS-diet-other scores (r = 0.04 providing evidence for validity. In multivariable analysis adjusted for age and gender, both the COMPASS-diet-self (F = 10.8, p < 0.001, r2 = 0.23 and other (F = 5.5, p < 0.001, r2 = 0.19 scales were significantly associated with weight loss achieved at program conclusion. COMPASS-diet surveys will allow group facilitators or trainers to identify patients who need additional support for optimal weight loss.

  19. Effect of changes in an FFQ: comparing data from two national dietary survey instruments among 2-year-olds.

    Science.gov (United States)

    Kristiansen, A L; Lillegaard, I T L; Lande, B; Andersen, L F

    2013-01-28

    In the interpretation of dietary trends, it is important to consider the potential effect of modifications in the dietary assessment method. Therefore, our objective was to explore the comparability of data obtained at two time points by a semi-quantitative FFQ (SFFQ) which has had slight modifications over time. In the national dietary surveys among Norwegian 2-year-olds, diet was assessed by an SFFQ which underwent modifications between the 1999 survey and the 2007 survey. In the present study, fifty-nine families with a 2-year-old child participated by completing both the SFFQ in a crossover design within a month's time. With regard to the reported intake of energy and nutrients, the largest significant differences observed between the two questionnaires were for carbohydrates and added sugar. According to intake of food groups, significant differences were observed for five out of sixteen food groups. Spearman's correlation coefficients for energy, nutrients and food groups ranged from 0.43 (Ca) to 0.85 (soft drinks). Most Bland-Altman plots indicated broad limits of agreement. The differences between the two questionnaires can be explained by changes in the questionnaires, changes in the food composition databases used and random variation. Comparing differences between the questionnaires by maternal educational level, number of children and type of day care revealed minor differences. In conclusion, this study showed that at the group level there was reasonable comparability between the two questionnaires, except for carbohydrates, added sugar and some food groups. Moreover, there were moderate to high correlations for energy, nutrients and food groups.

  20. The Swiss Health Literacy Survey: development and psychometric properties of a multidimensional instrument to assess competencies for health.

    Science.gov (United States)

    Wang, Jen; Thombs, Brett D; Schmid, Margareta R

    2014-06-01

    Growing recognition of the role of citizens and patients in health and health care has placed a spotlight on health literacy and patient education. To identify specific competencies for health in definitions of health literacy and patient-centred concepts and empirically test their dimensionality in the general population. A thorough review of the literature on health literacy, self-management, patient empowerment, patient education and shared decision making revealed considerable conceptual overlap as competencies for health and identified a corpus of 30 generic competencies for health. A questionnaire containing 127 items covering the 30 competencies was fielded as a telephone interview in German, French and Italian among 1255 respondents randomly selected from the resident population in Switzerland. Analyses with the software MPlus to model items with mixed response categories showed that the items do not load onto a single factor. Multifactorial models with good fit could be erected for each of five dimensions defined a priori and their corresponding competencies: information and knowledge (four competencies, 17 items), general cognitive skills (four competencies, 17 items), social roles (two competencies, seven items), medical management (four competencies, 27 items) and healthy lifestyle (two competencies, six items). Multiple indicators and multiple causes models identified problematic differential item functioning for only six items belonging to two competencies. The psychometric analyses of this instrument support broader conceptualization of health literacy not as a single competence but rather as a package of competencies for health. © 2012 John Wiley & Sons Ltd.

  1. Validation of a survey instrument to assess home environments for physical activity and healthy eating in overweight children

    Directory of Open Access Journals (Sweden)

    Crane Lori A

    2008-01-01

    Full Text Available Abstract Background Few measures exist to measure the overall home environment for its ability to support physical activity (PA and healthy eating in overweight children. The purpose of this study was to develop and test the reliability and validity of such a measure. Methods The Home Environment Survey (HES was developed to reflect availability, accessibility, parental role modelling, and parental policies related to PA resources, fruits and vegetables (F&V, and sugar sweetened drinks and snacks (SS. Parents of overweight children (n = 219 completed the HES and concurrent behavioural assessments. Children completed the Block Kids survey and wore an accelerometer for one week. A subset of parents (n = 156 completed the HES a second time to determine test-retest reliability. Finally, 41 parent dyads living in the same home (n = 41 completed the survey to determine inter-rater reliability. Initial psychometric analyses were completed to trim items from the measure based on lack of variability in responses, moderate or higher item to scale correlation, or contribution to strong internal consistency. Inter-rater and test-retest reliability were completed using intraclass correlation coefficients. Validity was assessed using Pearson correlations between the HES scores and child and parent nutrition and PA. Results Eight items were removed and acceptable internal consistency was documented for all scales (α = .66–84 with the exception of the F&V accessibility. The F&V accessibility was reduced to a single item because the other two items did not meet reliability standards. Test-retest reliability was high (r > .75 for all scales. Inter-rater reliability varied across scales (r = .22–.89. PA accessibility, parent role modelling, and parental policies were all related significantly to child (r = .14–.21 and parent (r = .15–.31 PA. Similarly, availability of F&V and SS, parental role modelling, and parental policies were related to child (r

  2. Validation of a survey instrument to assess home environments for physical activity and healthy eating in overweight children.

    Science.gov (United States)

    Gattshall, Michelle L; Shoup, Jo Ann; Marshall, Julie A; Crane, Lori A; Estabrooks, Paul A

    2008-01-11

    Few measures exist to measure the overall home environment for its ability to support physical activity (PA) and healthy eating in overweight children. The purpose of this study was to develop and test the reliability and validity of such a measure. The Home Environment Survey (HES) was developed to reflect availability, accessibility, parental role modelling, and parental policies related to PA resources, fruits and vegetables (F&V), and sugar sweetened drinks and snacks (SS). Parents of overweight children (n = 219) completed the HES and concurrent behavioural assessments. Children completed the Block Kids survey and wore an accelerometer for one week. A subset of parents (n = 156) completed the HES a second time to determine test-retest reliability. Finally, 41 parent dyads living in the same home (n = 41) completed the survey to determine inter-rater reliability. Initial psychometric analyses were completed to trim items from the measure based on lack of variability in responses, moderate or higher item to scale correlation, or contribution to strong internal consistency. Inter-rater and test-retest reliability were completed using intraclass correlation coefficients. Validity was assessed using Pearson correlations between the HES scores and child and parent nutrition and PA. Eight items were removed and acceptable internal consistency was documented for all scales (alpha = .66-84) with the exception of the F&V accessibility. The F&V accessibility was reduced to a single item because the other two items did not meet reliability standards. Test-retest reliability was high (r > .75) for all scales. Inter-rater reliability varied across scales (r = .22-.89). PA accessibility, parent role modelling, and parental policies were all related significantly to child (r = .14-.21) and parent (r = .15-.31) PA. Similarly, availability of F&V and SS, parental role modelling, and parental policies were related to child (r = .14-36) and parent (r = .15-26) eating habits. The

  3. Abnormal condition and events analysis for instrumentation and control systems. Volume 2: Survey and evaluation of industry practices. Final report

    International Nuclear Information System (INIS)

    McKemy, S.; Marcelli, M.; Boehmer, N.; Crandall, D.

    1996-01-01

    The ACES Project was initiated to identify a cost-effective methodology for addressing abnormal conditions and events (ACES) in digital upgrades to nuclear power plant systems, as introduced by IEEE Standard 7-4.3.2-1993. Several methodologies and techniques currently in use in the defense, aerospace, and other communities for the assurance of digital safety systems were surveyed, and although several were shown to possess desirable qualities, none sufficiently met the needs of the nuclear power industry. This report describes a tailorable methodology for performing ACES analysis that is based on the more desirable aspects of the reviewed methodologies and techniques. The methodology is applicable to both safety- and non-safety-grade systems, addresses hardware, software, and system-level concerns, and can be applied in either a lifecycle or post-design timeframe. Employing this methodology for safety systems should facilitate the digital upgrade licensing process

  4. Laser-Scanner Survey of Structural Disorders: AN Instrument to Inspect the History of Parma Cathedral's Central Nave

    Science.gov (United States)

    Bruno, N.; Coïsson, E.; Cotti, M.

    2017-05-01

    This paper presents the use of laser scanner derived data for the study of the structural disorders in the central nave of the Parma Cathedral. An accurate three-dimensional model of the entire nave was realized to investigate deformations, in order to reconstruct the original conformation and the subsequent evolutions, also in comparison with previous surveys. Specifically, for the analysis presented in the paper, seven scans were performed, one for each bay: the results allowed to compare the deformations on the seven vaults, on the transverse and diagonal arches, giving first hints on the possible differences in the behaviour between the different elements. The measures on the levels of floor and pillars bases were analysed in a historical monitoring approach, in order to retrace the evolution of the differential settlements in time, since the construction of the building. Moreover, a structural analysis has been carried out on one transverse arch with distinct element analysis, with two different approaches. In one case, the structure was inserted exactly as surveyed, and then subjected to the actions. In the second case, the original geometry, before the deformation, was retraced through a parametric approach and the structural analysis basically started at the beginning of the building's life, thus trying to model not only the present structural situation, but also the path which led to the current deformation. The results were particularly meaningful as they showed that in the first case, disregarding the footsteps of history, the stress pattern inside the masonry was very different from the one obtained in the second case, which is more likely to represent the present conditions.

  5. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    Science.gov (United States)

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  6. SURVEY

    DEFF Research Database (Denmark)

    SURVEY er en udbredt metode og benyttes inden for bl.a. samfundsvidenskab, humaniora, psykologi og sundhedsforskning. Også uden for forskningsverdenen er der mange organisationer som f.eks. konsulentfirmaer og offentlige institutioner samt marketingsafdelinger i private virksomheder, der arbejder...... med surveys. Denne bog gennemgår alle surveyarbejdets faser og giver en praktisk indføring i: • design af undersøgelsen og udvælgelse af stikprøver, • formulering af spørgeskemaer samt indsamling og kodning af data, • metoder til at analysere resultaterne...

  7. Radiation measurement instruments

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The requirements and characteristics of radiation measurement instruments vary according to the circumstances under which they are used (field, area, laboratory conditions) and according to their purpose (radiation survey, personal monitoring, use in emergencies, or alpha, beta or gamma counting). In fact, radiation measurement instruments are so varied that only an overview has been presented here. Groups of instruments for these and other conditions or uses are presented in tabular form together with their operational characteristics and requirements. While examples of calibrations, efficiencies and variability of all the listed instruments are not given in this chapter, these parameters are illustrated for the most important types of gamma and beta survey instruments, in some cases with a specific instrument used as an example. Some of the important parameters that need to be considered for laboratory counting of alpha and beta particles are presented. Charts for determination of optimum sample and background counting times, errors and statistics are given

  8. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  9. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  10. Assessing quality of maternity care in Hungary: expert validation and testing of the mother-centered prenatal care (MCPC) survey instrument.

    Science.gov (United States)

    Rubashkin, Nicholas; Szebik, Imre; Baji, Petra; Szántó, Zsuzsa; Susánszky, Éva; Vedam, Saraswathi

    2017-11-16

    Instruments to assess quality of maternity care in Central and Eastern European (CEE) region are scarce, despite reports of poor doctor-patient communication, non-evidence-based care, and informal cash payments. We validated and tested an online questionnaire to study maternity care experiences among Hungarian women. Following literature review, we collated validated items and scales from two previous English-language surveys and adapted them to the Hungarian context. An expert panel assessed items for clarity and relevance on a 4-point ordinal scale. We calculated item-level Content Validation Index (CVI) scores. We designed 9 new items concerning informal cash payments, as well as 7 new "model of care" categories based on mode of payment. The final questionnaire (N = 111 items) was tested in two samples of Hungarian women, representative (N = 600) and convenience (N = 657). We conducted bivariate analysis and thematic analysis of open-ended responses. Experts rated pre-existing English-language items as clear and relevant to Hungarian women's maternity care experiences with an average CVI for included questions of 0.97. Significant differences emerged across the model of care categories in terms of informal payments, informed consent practices, and women's perceptions of autonomy. Thematic analysis (N = 1015) of women's responses identified 13 priority areas of the maternity care experience, 9 of which were addressed by the questionnaire. We developed and validated a comprehensive questionnaire that can be used to evaluate respectful maternity care, evidence-based practice, and informal cash payments in CEE region and beyond.

  11. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  12. Pancreatitis Quality of Life Instrument: Development of a new instrument

    OpenAIRE

    Wassef, Wahid; Bova, Carol; Barton, Bruce; Hartigan, Celia

    2014-01-01

    Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Fi...

  13. A Survey of Florida High School Instrumental Music Programs: Rationale for the Inclusion of Jazz Ensemble Experience in Music Teacher Training

    Science.gov (United States)

    Hinkle, Jonathan R.

    2011-01-01

    During the past 60 years, jazz music has slowly become recognized as a genre worthy of study in high school music programs throughout the United States. Only a few researchers have analyzed large samples of jazz-related instruction in instrumental music programs, and of these studies no data were collected to investigate the inclusion of jazz in…

  14. Readiness Issues for Emergency Response Instrumentation

    International Nuclear Information System (INIS)

    Riland, C.A.; Bowman, D.R.; Tighe, R.J.

    1999-01-01

    Issues in maintaining readiness of instruments for deployment and use in emergency response situations often differ from those in maintaining instruments for normal operations. Confunding circumstances include use or non-availability of check sources, ensuring instruments are always in calibration and operable, possible use of instruments in different climates, packaging of instrumentation for deployment, transport of instrumentation and check sources, and ensuring users are familiar with the instruments. Methods and procedures for addressing these issues are presented. Instrumentation used for survey, in situ measurements, electronic dosimetry, and air monitoring are discussed

  15. Readiness Issues for Emergency Response Instrumentation

    International Nuclear Information System (INIS)

    Riland, C.A.; Bowman, D.R.; Tighe, R.J.

    1999-01-01

    Issues in maintaining readiness of instruments for deployment and use in emergency response situation often differ from those in maintaining instruments for normal operations. Confunding circumstances include use of non-availability of check sources, ensuring instruments are always in calibration and operable, possible use of instruments in different climates, packaging of instrumentation for deployment, transport of instrumentation and check sources, and ensuring users are familiar with instruments. Methods and procedures for addressing these issues are presented. Instrumentation used for survey, in situ measurements, electronic dosimetry, and air conditioning are discussed

  16. Luminescence Instrumentation

    DEFF Research Database (Denmark)

    Jain, Mayank; Bøtter-Jensen, Lars

    2014-01-01

    This chapter gives an introduction to instrumentation for stimulated luminescence studies, with special focus on luminescence dating using the natural dosimeters, quartz and feldspars. The chapter covers basic concepts in luminescence detection, and thermal and optical stimulation, and reference...

  17. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  18. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  19. Considerations in comparing the U.S. Geological Survey one‐year induced‐seismicity hazard models with “Did You Feel It?” and instrumental data

    Science.gov (United States)

    White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie

    2017-01-01

    The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.

  20. NURE aerial gamma-ray and magnetic-reconnaissance survey portions of New Mexico, Arizona, and Texas. Volume I. Instrumentation and data reduction. Final report

    International Nuclear Information System (INIS)

    1981-09-01

    As part of the Department of Energy (DOE) National Uranium Resource Evaluation Program, a rotary-wing high sensitivity radiometric and magnetic survey was flown covering portions of the State of New Mexico, Arizona and Texas. The survey encompassed six 1:250,000 scale quadrangles, Holbrook, El Paso, Las Cruces, Carlsbad, Fort Sumner and Roswell. The survey was flown with a Sikorsky S58T helicopter equipped with a high sensitivity gamma ray spectrometer which was calibrated at the DOE calibration facilities at Walker Field in Grand Junction, Colorado, and the Dynamic Test Range at Lake Mead, Arizona. The radiometric data were processed to compensate for Compton scattering effects and altitude variations. The data were normalized to 400 feet terrain clearance. The reduced data is presented in the form of stacked profiles, standard deviation anomaly plots, histogram plots and microfiche listings. The results of the geologic interpretation of the radiometric data together with the profiles, anomaly maps and histograms are presented in the individual quadrangle reports. The survey was awarded to LKB Resources, Inc. which completed the data acquisition. In April, 1980 Carson Helicopters, Inc. and Carson Geoscience Company agreed to manage the project and complete delivery of this final report

  1. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  2. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  3. Instrumented SSH

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Scott; Campbell, Scott

    2009-05-27

    NERSC recently undertook a project to access and analyze Secure Shell (SSH) related data. This includes authentication data such as user names and key fingerprints, interactive session data such as keystrokes and responses, and information about noninteractive sessions such as commands executed and files transferred. Historically, this data has been inaccessible with traditional network monitoring techniques, but with a modification to the SSH daemon, this data can be passed directly to intrusion detection systems for analysis. The instrumented version of SSH is now running on all NERSC production systems. This paper describes the project, details about how SSH was instrumented, and the initial results of putting this in production.

  4. Active instruments

    DEFF Research Database (Denmark)

    Lim, Miguel Antonio; Ørberg, Jakob Williams

    2017-01-01

    ) show the dynamic nature of policy processes, and (3) consider the search for policy reference points among the different actors. We present rankers in motion, policies in motion, and finally the complex nature of the ranking device that needs to be both a relevant and malleable policy instrument...

  5. Seismic instrumentation

    International Nuclear Information System (INIS)

    Maubach, K.

    1982-01-01

    For better understanding of the specification for seismic instrumentation of a nuclear power plant, the lecture gives some fundamental remarks to the seismic risk in the Federal Republic of Germany and to the data characterizing an earthquake event. Coming from the geophysical properties of an earthquake, the quantities are explained which are used in the design process of nuclear power plants. This process is shortly described in order to find the requirements for the specification of the seismic instrumentation. In addition the demands of licensing authorities are given. As an example the seismic instrumentation of KKP-1, BWR, is shown. The paper deals with kind and number of instruments, their location in the plant and their sensitivity and calibration. Final considerations deal with the evaluation of measured data and with plant operation after an earthquake. Some experience concerning the earthquake behaviour of equipment not designed to withstand earthquake loads is mentioned. This experience has initiated studies directed to quantification of the degree of conservatism of the assumptions in the seismic design of nuclear power plants. A final garget of these studies are more realistic design rules. (RW)

  6. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  7. Development of an instrument to measure seniors' patient safety health beliefs: the Seniors Empowerment and Advocacy in Patient Safety (SEAPS) survey.

    Science.gov (United States)

    Elder, Nancy C; Regan, Saundra L; Pallerla, Harini; Levin, Linda; Post, Douglas; Cegela, Donald J

    2007-12-01

    To develop a survey to measure seniors' embracement of ambulatory patient safety self-advocacy behaviors, the Senior Empowerment and Advocacy in Patient Safety (SEAPS) survey. Content was developed by review of published recommendations combined with interviews and focus groups with community members; items were generated for subscales based on the health belief model (HBM). Psychometric characteristics were assessed by cluster and correlation analyses on a pilot test of 143 community dwelling seniors; the ability of the subscales and demographic variables to predict reported behavior was investigated by multiple regression. The four subscales of the SEAPS were outcome efficacy (OE), attitudes (ATT), self-efficacy (SE) and behaviors (BEH). Cronbach alphas were 0.74 for ATT, 0.79 for BEH, and 0.91 for OE and SE. Analysis of variance showed that there were no differences in any subscale score by race, education level or frequency of doctor visits, but women were noted to have significantly higher scores (pprograms aimed at improving seniors' self-advocacy skills. Effective interventions may improve the involvement of patients in their own safety in the clinical setting.

  8. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  9. Nuclear instrumentation

    International Nuclear Information System (INIS)

    Weill, Jacky; Fabre, Rene.

    1981-01-01

    This article sums up the Research and Development effort at present being carried out in the five following fields of applications: Health physics and Radioprospection, Control of nuclear reactors, Plant control (preparation and reprocessing of the fuel, testing of nuclear substances, etc.), Research laboratory instrumentation, Detectors. It also sets the place of French industrial activities by means of an estimate of the French market, production and flow of trading with other countries [fr

  10. Development and evaluation of the Fe-BARQ: A new survey instrument for measuring behavior in domestic cats (Felis s. catus).

    Science.gov (United States)

    Duffy, Deborah L; de Moura, Roseana T Diniz; Serpell, James A

    2017-08-01

    A questionnaire instrument for obtaining quantitative behavioral evaluations of pet cats from cat owners was developed and validated. Exploratory Factor Analysis of 2608 questionnaire responses to 149 behavioral questions/items extracted a total of 23 distinct factors that measured most of the more common dimensions of cat behavior. Seventeen of the 23 factors demonstrated adequate-high internal reliability (Cronbach's alpha=0.712-0.923). Questionnaire validation was accomplished by determining: (a) whether owners' subjective ratings of the severity of their cat's behavior problems were associated with cats' actual scores on expected questionnaire factors, (b) whether expected associations between specific demographic and/or lifestyle characteristics and behavior were confirmed by cats' factor or item scores on the questionnaire, and (c) whether breed rankings based on owner-reported factor scores matched those previously derived from the opinions of experts (veterinarians). The results of these various tests confirmed the overall construct validity of the questionnaire. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Surgical robotics beyond enhanced dexterity instrumentation: a survey of machine learning techniques and their role in intelligent and autonomous surgical actions.

    Science.gov (United States)

    Kassahun, Yohannes; Yu, Bingbin; Tibebu, Abraham Temesgen; Stoyanov, Danail; Giannarou, Stamatia; Metzen, Jan Hendrik; Vander Poorten, Emmanuel

    2016-04-01

    robotics. Current devices possess no intelligence whatsoever and are merely advanced and expensive instruments.

  12. Question order sensitivity of subjective well-being measures: focus on life satisfaction, self-rated health, and subjective life expectancy in survey instruments.

    Science.gov (United States)

    Lee, Sunghee; McClain, Colleen; Webster, Noah; Han, Saram

    2016-10-01

    This study examines the effect of question context created by order in questionnaires on three subjective well-being measures: life satisfaction, self-rated health, and subjective life expectancy. We conducted two Web survey experiments. The first experiment (n = 648) altered the order of life satisfaction and self-rated health: (1) life satisfaction asked immediately after self-rated health; (2) self-rated health immediately after life satisfaction; and (3) two items placed apart. We examined their correlation coefficient by experimental condition and further examined its interaction with objective health. The second experiment (n = 479) asked life expectancy before and after parental mortality questions. Responses to life expectancy were compared by order using ANOVA, and we examined interaction with parental mortality status using ANCOVA. Additionally, response time and probes were examined. Correlation coefficients between self-rated health and life satisfaction differed significantly by order: 0.313 (life satisfaction first), 0.508 (apart), and 0.643 (self-rated health first). Differences were larger among respondents with chronic conditions. Response times were the shortest when self-rated health was asked first. When life expectancy asked after parental mortality questions, respondents reported considering parents more for answering life expectancy; and respondents with deceased parents reported significantly lower expectancy, but not those whose parents were alive. Question context effects exist. Findings suggest placing life satisfaction and self-rated health apart to avoid artificial attenuation or inflation in their association. Asking about parental mortality prior to life expectancy appears advantageous as this leads respondents to consider parental longevity more, an important factor for true longevity.

  13. Audio computer-assisted survey instrument versus face-to-face interviews: optimal method for detecting high-risk behaviour in pregnant women and their sexual partners in the south of Brazil.

    Science.gov (United States)

    Yeganeh, N; Dillavou, C; Simon, M; Gorbach, P; Santos, B; Fonseca, R; Saraiva, J; Melo, M; Nielsen-Saines, K

    2013-04-01

    Audio computer-assisted survey instrument (ACASI) has been shown to decrease under-reporting of socially undesirable behaviours, but has not been evaluated in pregnant women at risk of HIV acquisition in Brazil. We assigned HIV-negative pregnant women receiving routine antenatal care at in Porto Alegre, Brazil and their partners to receive a survey regarding high-risk sexual behaviours and drug use via ACASI (n = 372) or face-to-face (FTF) (n = 283) interviews. Logistic regression showed that compared with FTF, pregnant women interviewed via ACASI were significantly more likely to self-report themselves as single (14% versus 6%), having >5 sexual partners (35% versus 29%), having oral sex (42% versus 35%), using intravenous drugs (5% versus 0), smoking cigarettes (23% versus 16%), drinking alcohol (13% versus 8%) and using condoms during pregnancy (32% versus 17%). Therefore, ACASI may be a useful method in assessing risk behaviours in pregnant women, especially in relation to drug and alcohol use.

  14. Effect of changes in a food frequency questionnaire: comparing data from two national dietary survey instruments among 12-month-old infants.

    Science.gov (United States)

    Kristiansen, Anne Lene; Laugsand Lillegaard, Inger Therese; Frost Andersen, Lene

    2013-07-24

    National dietary surveys among Norwegian 12-months olds have been conducted twice: in 1999 and 2007. At both time-points diet were assessed by a semi-quantitative food frequency questionnaire (SFFQ) (the SFFQ-1999 and the SFFQ-2007). Modifications in the SFFQ-2007 compared to the SFFQ-1999 have been made; therefore, the objective of the present study has been to explore the comparability of the data obtained by the two questionnaires. Moreover, reliability of maternal recall of infant feeding practices was assessed. Three hundred Norwegian infants born in April 2007 were invited to participate by completing both the SFFQ-1999 and the SFFQ-2007. An invitation letter and one of two questionnaires were sent by mail to the mother/parents about two weeks before the child turned 12 months of age. The study had a cross-over design where half of the sample received the SFFQ-1999 first and then about 2-3 weeks later they received the SFFQ-2007. The second half received the SFFQ-2007 first, and then 2-3 weeks later they received the SFFQ-1999. Ninety three participants completed both questionnaires (SFFQ-1999 and SFFQ-2007). For nutrients, the largest significant differences between the questionnaires were found for intake of vitamin D and added sugar, where added sugar was reported lower and vitamin D was reported higher with the SFFQ-2007 compared to the SFFQ-1999. For food items, lower intake of yoghurt and higher intake of vegetables and fish were observed with the SFFQ-2007 compared to the SFFQ-1999. In addition, reliable answers with regard to breastfeeding status, age for breastfeeding cessation and age for introducing solid foods were found. There was reasonable comparability between the two questionnaires for most nutrients and foods. The differences between the two questionnaires could mainly be explained by modifications that had occurred over time, where changes in the food composition databases used and especially changes in commercial recipes with regard to

  15. Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions

    Directory of Open Access Journals (Sweden)

    Reid Savanna R

    2011-02-01

    Full Text Available Abstract Background Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are problematic because health workers often behave differently under the observation of visitors. The main objective of this study is to assess the extent of unsafe injection equipment reuse and potential for blood-borne virus transmission in Cameroon. This can be done by probing for misconceptions about injection safety that explain reuse without sterilization. These misconceptions concern useless precautions against cross-contamination, i.e. "indirect reuse" of injection equipment. To investigate whether a shortage of supply explains unsafe reuse, we compared our survey data against records of purchases. Methods All health workers at public hospitals in two health districts in the Northwest Province of Cameroon were interviewed about their own injection practices. Injection equipment supply purchase records documented for January to December 2009 were compared with self-reported rates of syringe reuse. The number of HIV, HBV and HCV infections that result from unsafe medical injections in these health districts is estimated from the frequency of unsafe reuse, the number of injections performed, the probability that reused injection equipment had just been used on an infected patient, the size of the susceptible population, and the transmission efficiency of each virus in an injection. Results Injection equipment reuse occurs commonly in the Northwest Province of Cameroon, practiced by 44% of health workers at public hospitals. Self-reported rates of syringe reuse only partly explained by records on injection equipment supplied to these hospitals, showing a shortage of syringes where syringes are reused. Injection safety interventions could

  16. Seismic instrumentation

    International Nuclear Information System (INIS)

    1984-06-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The aim of this RFS is to define the type, location and operating conditions for seismic instrumentation needed to determine promptly the seismic response of nuclear power plants features important to safety to permit comparison of such response with that used as the design basis

  17. The 4MOST instrument concept overview

    NARCIS (Netherlands)

    Haynes, Roger; Barden, Samuel; de Jong, Roelof; Schnurr, Olivier; Bellido, Olga; Walcher, Jakob; Haynes, Dionne; Winkler, Roland; Bauer, Svend-Marian; Dionies, Frank; Saviauk, Allar; Chiappini, Cristina; Schwope, Axel; Brynnel, Joar; Steinmetz, Matthias; McMahon, Richard; Feltzing, Sofia; Francois, Patrick; Trager, Scott; Parry, Ian; Irwin, Mike; Walton, Nicholas; King, David; Sun, David; Gonzalez-Solares, Eduaro; Tosh, Ian; Dalton, Gavin; Middleton, Kevin; Bonifacio, Piercarlo; Jagourel, Pascal; Mignot, Shan; Cohen, Mathieu; Amans, Jean-Philippe; Royer, Frederic; Sartoretti, Paola; Pragt, Johan; Gerlofsma, Gerrit; Roelfsema, Ronald; Navarro, Ramon; Thimm, Guido; Seifert, Walter; Christlieb, Norbert; Mandel, Holger; Trifonov, Trifon; Xu, Wenli; Lang-Bardl, Florian; Muschielok, Bernard; Schlichter, Jörg; Hess, Hans-Joachim; Grupp, Frank; Boehringer, Hans; Boller, Thomas; Dwelly, Tom; Bender, Ralf; Rosati, Piero; Iwert, Olaf; Finger, Gert; Lizon L'Allemand, Jean-Louis; Saunders, Will; Sheinis, Andrew; Frost, Gabriella; Farrell, Tony; Waller, Lewis; Depagne, Eric; Laurent, Florence; Caillier, Patrick; Kosmalski, Johan; Richard, Johan; Bacon, Roland; Ansorge, Wolfgang

    2014-01-01

    The 4MOST[1] instrument is a concept for a wide-field, fibre-fed high multiplex spectroscopic instrument facility on the ESO VISTA telescope designed to perform a massive (initially >25x106 spectra in 5 years) combined all-sky public survey. The main science drivers are: Gaia follow up of

  18. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  19. Low activated incore instrument

    Science.gov (United States)

    Ekeroth, D.E.

    1994-04-19

    Instrumentation is described for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials. 9 figures.

  20. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  1. Evaluating musical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, D. Murray

    2014-04-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.

  2. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  3. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  4. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  5. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  6. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  7. 10 CFR 39.33 - Radiation detection instruments.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation detection instruments. 39.33 Section 39.33... Equipment § 39.33 Radiation detection instruments. (a) The licensee shall keep a calibrated and operable radiation survey instrument capable of detecting beta and gamma radiation at each field station and...

  8. International standards and quality control procedures applied to nuclear instruments

    International Nuclear Information System (INIS)

    Urbanski, P.

    2008-01-01

    The survey of international standards related to Nuclear Instrumentation and QC tests was presented. From among the 29'336 active international standards published by such organizations as ISO, IEC, CEN and CENELEC, only 582 are devoted to nuclear instruments. The international classification of standards (ICS) is shown. Also, the list of 582 international standards related to nuclear instruments is attached. (author)

  9. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1985-01-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy

  10. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  11. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... provides the performer extensive virtuoso capabilities in terms of instrumental range, harmony, timbre, or spatial, textural, acoustic, technical, or technological qualities. The discussion will be illustrated by a composition case study involving augmented musical instrument electromagnetic resonator...

  12. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  13. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, Abraham; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  14. Environmental Communication Instruments for Environmental Policy Integration

    Science.gov (United States)

    Lagzdina, Erika

    2010-01-01

    Two public policy concepts - modernization of governance and environmental policy integration - serve as the basis for this work. The author links them up with environmental communication (EC) as an integration instrument approach, and tests application at the local level in Latvia. Totally 30 case studies were analysed and survey methods used to interview over 70 people. The article verifies driving forces affecting the internal and external integration of environmental policy, explicates EC instrumentality for integration by assessing policy instruments and stakeholders. The final conclusions affirm that, in order to integrate environmental management into municipal development, it is necessary to establish a complementary set of policy instruments, what might be enabled by wise use of all EC components in their interactivity. The complementarity of EC instruments and stakeholder group efforts forms synergy and enhances better environmental policy integration.

  15. Nuclear instrumentation for uranium exploration

    International Nuclear Information System (INIS)

    Sarma, Ch. V.N.; Sarma, C.V.R.; Sreehari, R.

    1999-01-01

    Instrumentation required for uranium exploration may be broadly classified based on surface and sub-surface measurement of gamma-ray intensity. Surface measurement of gross and spectral gamma intensity are carried out by employing portable Geiger Mueller/scintillation counters and four-channel spectrometers. Measurement of thoron ( 220 Rn) and radon ( 222 Rn) in the soil gas is being carried out by closed circuit technique using radon measuring system. Radiometric mapping of trenches, pits and mine-faces are carried out using shielded probe with 2π source geometry, whereas logging sonde with instruments through the steel armoured cable are employed for point to 4π geometry. Spectral borehole logging system with built-in multi-channel analyser (MCA) has been developed for the uranium exploration programme for AMD. Note-book PC based high sensitivity air-borne gamma-ray spectrometric survey system has been designed, developed and test flown. (author)

  16. Measurement of dose equivalent with personal dosemeters and instrumentation of radiological protection in the new operative magnitudes ICRU, for external fields of radiation beta. Part IV. Survey of the angular response of instruments used in radiological protection in secondary patron fields of beta radiation (90Sr/90Y (1850 MBq and 74 MBq), 204TI (18.5 MBq) and 147Pm (518 MBq)

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-02-01

    Tests type were made (type test) in the following commercial instrumentation commonly used in radiological protection: Geiger-Mueller Counters (FH40 FE), Plastic Scintillators (NE-BP/6/4A), Ionization Chambers (RO-5) and Proportional Counters (HP-100A; gas:P-10). With object of checking the possibility that these they can carry out the new operative unit ICRU, H' (0.07; α). The tests consisted on determining the energy and angular response of the detectors in secondary patron fields of beta radiation, for isotopes of 90 Sr/ 90 Y (1850 MBq and 74 MBq and 147 Pm(518 MBq). The results show the inadequate of these commercial instruments for the realization of the H' operative unit (0.07; α) in beta external fields. Due to flaws in the design, construction and calibration of the instruments for this type of radiation fields (Author)

  17. Marine chemistry, fish / shell-fish surveys, benthic organisms, and marine toxic substances and pollutants data from current meter and other instruments in the Gulf of Mexico from 1993-01-26 to 1994-06-13 (NODC Accession 9500088)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Marine chemistry, fish / shell-fish surveys, benthic organisms, and marine toxic substances and pollutants data were collected using current meter and other...

  18. PEP Laser Surveying System

    International Nuclear Information System (INIS)

    Lauritzen, T.; Sah, R.C.

    1979-03-01

    A Laser Surveying System has been developed to survey the beam elements of the PEP storage ring. This system provides automatic data acquisition and analysis in order to increase survey speed and to minimize operator error. Two special instruments, the Automatic Readout Micrometer and the Small Automatic Micrometer, have been built for measuring the locations of fiducial points on beam elements with respect to the light beam from a laser. These instruments automatically encode offset distances and read them into the memory of an on-line computer. Distances along the beam line are automatically encoded with a third instrument, the Automatic Readout Tape Unit. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compared them with desired parameters, and calculates the required adjustments to beam element support stands

  19. Instrumentation for accelerators

    International Nuclear Information System (INIS)

    Sen, T.J.; De, T.K.; Ranganathan, M.K.; Basak, G.C.

    1989-01-01

    Along with the various system development for the accelerator, it was necessary to develop the instrumentation facility for the cyclotron. It started with the development of various vacuum instruments like ionization gauge control unit for measurement of pressure from 10 -4 torr to 10 -9 torr, discharge gauge control unit from 10 -4 torr to 10 -7 torr, thermocouple gauge control unit from 1 torr to 10 -3 torr. Process control instrumentation includes temperature measurement for freon cooled baffle and als o for low conductivity water. Control console required various digital panel meters for measurement of various parameters of the cyclotron. Various radiation monitoring instruments are also taken care of by the instrumentation facility. This paper describes in brief these various instruments. (author). 3 f igs

  20. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  1. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  2. Ocean Optics Instrumentation Systems

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides instrumentation suites for a wide variety of measurements to characterize the ocean’s optical environment. These packages have been developed to...

  3. Networked Instrumentation Element

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a networked instrumentation system that connects modern experimental payloads to existing analog and digital communications...

  4. Creating a Super Instrument

    DEFF Research Database (Denmark)

    Kallionpää, Maria; Gasselseder, Hans-Peter

    2015-01-01

    interested in different ways of "supersizing" acoustic instruments in order to open up previously-unheard instrumental sounds. This leads us to the question of what constitutes a super instrument and what challenges does it pose aesthetically and technically? Although the classical music performers have......Thanks to the development of new technology, musical instruments are no more tied to their existing acoustic or technical limitations as almost all parameters can be augmented or modified in real time. An increasing number of composers, performers, and computer programmers have thus become...

  5. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  6. Instrument performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program.

  7. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    Science.gov (United States)

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p  0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Towards an Enterprise Architecture Benefits Measurement Instrument

    NARCIS (Netherlands)

    Dr.ir. Raymond Slot; Henk Plessius; Marlies Steenbergen, van

    2015-01-01

    Author supplied: Based on the Enterprise Architecture Value Framework (EAVF) - a generic framework to classify benefits of Enterprise Architecture (EA) - a measurement instrument for EA benefits has been developed and tested in a survey with 287 respondents. In this paper we present the results of

  9. Instrumentation Design and Development Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC has facilities for design, development and fabrication of: custominstrumentation, mobile instrumentation, miniaturized instrumentation, wirelessinstrumentation,...

  10. Overview of LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed

  11. Peer Learning in Instrumental Practicing.

    Science.gov (United States)

    Nielsen, Siw G; Johansen, Guro G; Jørgensen, Harald

    2018-01-01

    In higher music education (HME), the notion of "private teaching, private learning" has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy ( N = 96), where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation.

  12. Peer Learning in Instrumental Practicing

    Directory of Open Access Journals (Sweden)

    Siw G. Nielsen

    2018-03-01

    Full Text Available In higher music education (HME, the notion of “private teaching, private learning” has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy (N = 96, where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation.

  13. Peer Learning in Instrumental Practicing

    Science.gov (United States)

    Nielsen, Siw G.; Johansen, Guro G.; Jørgensen, Harald

    2018-01-01

    In higher music education (HME), the notion of “private teaching, private learning” has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy (N = 96), where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation. PMID:29599738

  14. INSTRUMENTATION FOR ENVIRONMENTAL MONITORING--Radiation--Vol3Pt1

    Energy Technology Data Exchange (ETDEWEB)

    Authors, Various

    1972-01-02

    A comprehensive survey of instrumentation for environmental monitoring is being carried out by the Lawrence Berkeley Laboratory originally under a grant from the National Science Foundation and now by the Office of Health and Environmental Research of the Department of Energy. Instruments being investigated are those useful for measurements in Air Quality, Water Quality, Radiation, and Biomedicine related to environmental research and monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to this work. The results of the survey are given as (a) descriptions of the physical and operating characteristics of available instruments, (b) critical comparisons among instrumentation methods, and (c) recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored: their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls.

  15. Remote instrument telemaintenance.

    Science.gov (United States)

    Laugier, A; Allahwerdi, N; Baudin, J; Gaffney, P; Grimson, W; Groth, T; Schilders, L

    1996-07-01

    In the past decade, great technological progress has been made in telemaintenance of mainframe and mini computers. As hardware technology is now available at an acceptable cost, computer aided trouble-shooting can be adapted to laboratory instrumentation in order to significantly improve repair time, avoid instrument downtime by taking advantage of predictive methods, and provide general diagnostic assistance. Depending on the size of the instrument, the telemaintenance facility can be dedicated to a single instrument or alternatively a telemaintenance server can manage multiple distributed small instruments through a Local Area Network. As complex failures can occur, the local diagnosis capabilities may be exceeded and automatic dialing for connection to computerized Remote Maintenance Centers is needed. The main advantages of such a centre, as compared to local diagnosis systems, are the increased access to more information and experience of failures from instrument installations, and consequently the provision of training data updates for Artificial Neural Networks and Knowledge Based Systems in general. When an abnormal situation is detected or anticipated by a diagnosis module, an automatic alert is given to the user, local diagnosis is activated, and for simple solutions, instructions are given to the operator. In the last resort, a human expert can be alerted who, with remote control tools, can attend to the failures. For both local and remote trouble-shooting, the data provided by the instrument and connected workstation is of paramount importance for the efficiency and accuracy of the diagnosis. Equally, the importance of standardization of telemaintenance communication protocols is addressed.

  16. Ethical Considerations for Data Collection Using Surveys.

    Science.gov (United States)

    Hammer, Marilyn J

    2017-03-01

    Surveys are widely used instruments to collect research data. Although surveys may appear relatively benign and easily unlinked to participants, considerations for the ethical conduct of research with surveys are important. Maintaining scientific rigor is essential. This article explores ethical tenets in relation to informed consent and scientific consent when using surveys.

  17. Medical instruments in museums

    DEFF Research Database (Denmark)

    Söderqvist, Thomas; Arnold, Ken

    2011-01-01

    This essay proposes that our understanding of medical instruments might benefit from adding a more forthright concern with their immediate presence to the current historical focus on simply decoding their meanings and context. This approach is applied to the intriguingly tricky question of what...... actually is meant by a "medical instrument." It is suggested that a pragmatic part of the answer might lie simply in reconsidering the holdings of medical museums, where the significance of the physical actuality of instruments comes readily to hand....

  18. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  19. Microcomputers for nuclear instrumentation

    International Nuclear Information System (INIS)

    Byrd, J.S.

    1979-01-01

    Small, desk-top Commodore PET computers are being used to solve nuclear instrumentation problems at the Savannah River Laboratory (SRL). The ease of operating, programing, interfacing, and maintaining the PET computer makes it a cost-effective solution to many real-time instrumentation problems that involve both data acquisition and date processing. The IEEE-488 GPIB (General Purpose Instrument Bus) is an integral part of the PET hardware. This paper reviews GPIB design concepts and discusses SRL applications that use the PET computer as a GPIB controller. 11 figures, 2 tables

  20. The latest radiation instrument

    International Nuclear Information System (INIS)

    Kang, Se Sik; Gwon, Dal Gwan; Kim, Gyeong Geum

    2008-08-01

    This book deals with the latest radiation instrument, which is comprised of eight chapters. It explains X rays instrument for medial treatment, X-ray tube instrument and permissible burden with its history, structure and characteristic high voltage apparatus with high voltage rectifier circuit, X-ray control apparatus for medical treatment, X-ray image equipment X-ray television apparatus and CCD 205, X-ray apparatus of install and types, Digital X-ray apparatus with CR 261 and DR 269, performance management on X-ray for medical treatment with its history, necessity and management in the radiation field.

  1. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  2. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  3. Human factors aspects of advanced instrumentation in the nuclear industry

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    An important consideration in regards to the use of advanced instrumentation in the nuclear industry is the interface between the instrumentation system and the human. A survey, oriented towards identifying the human factors aspects of digital instrumentation, was conducted at a number of United States (US) and Canadian nuclear vendors and utilities. Human factors issues, subsumed under the categories of computer-generated displays, controls, organizational support, training, and related topics were identified. 20 refs., 2 tabs

  4. An intelligent instrument for measuring the dynamic parameters of groundwater

    International Nuclear Information System (INIS)

    Du Guoping

    2002-01-01

    An intelligent instrument was developed for measuring direction and velocity of the groundwater, permeability coefficient, hydraulic transmitting coefficient, static level, hydraulic gradient and flow direction of each layer. The instrument can be widely applied for detecting seepage of abutment and river bank, exploitation of groundwater, conservation of water and soil, water surging in mine, survey of groundwater resource and environment protection etc

  5. Carbon Footprint Reduction Instruments

    Science.gov (United States)

    This page outlines the major differences between Renewable Energy Certificates (REC) and Project Offsets and what types of claims each instrument allows the organization to make in regards to environmental emissions claims.

  6. CCAT Heterodyne Instrument Development

    Data.gov (United States)

    National Aeronautics and Space Administration — This work will extend and proof-out the design concept for a high pixel count (128 pixels in 2 bands) submillimeter-wave heterodyne receiver array instrument for the...

  7. Fiber Optics Instrumentation Development

    Science.gov (United States)

    Chan, Patrick Hon Man; Parker, Allen R., Jr.; Richards, W. Lance

    2010-01-01

    This is a general presentation of fiber optics instrumentation development work being conducted at NASA Dryden for the past 10 years and recent achievements in the field of fiber optics strain sensors.

  8. Medical instruments in museums

    DEFF Research Database (Denmark)

    Söderqvist, Thomas; Arnold, Ken

    2011-01-01

    This essay proposes that our understanding of medical instruments might benefit from adding a more forthright concern with their immediate presence to the current historical focus on simply decoding their meanings and context. This approach is applied to the intriguingly tricky question of what a...... actually is meant by a "medical instrument." It is suggested that a pragmatic part of the answer might lie simply in reconsidering the holdings of medical museums, where the significance of the physical actuality of instruments comes readily to hand.......This essay proposes that our understanding of medical instruments might benefit from adding a more forthright concern with their immediate presence to the current historical focus on simply decoding their meanings and context. This approach is applied to the intriguingly tricky question of what...

  9. Challenges in marine instrumentation

    Digital Repository Service at National Institute of Oceanography (India)

    Afzulpurkar, S.; Desa, E.; Joseph, A.; Chakraborty, B.; Nayak, M.R.; Ranade, G.

    challenge for technology. Biosensors which can detect bioluminescence and other biological activities would play a major role. Autonomous instrumentation outfitted with different types of in-situ sensors would collect data without disturbing the system...

  10. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  11. The LUVOIR architecture "A" coronagraph instrument

    Science.gov (United States)

    Pueyo, L.; Zimmerman, N.; Bolcar, M.; Groff, T.; Stark, C.; Ruane, G.; Jewell, J.; Soummer, R.; St. Laurent, K.; Wang, J.; Redding, D.; Mazoyer, J.; Fogarty, K.; Juanola-Parramon, Roser; Domagal-Goldman, S.; Roberge, A.; Guyon, O.; Mandell, A.

    2017-09-01

    In preparation for the Astro 2020 Decadal Survey NASA has commissioned the study four flagship missions spanning to a wide range of observable wavelengths: the Origins Space Telescope (OST, formerly the Far-Infrared Surveyor), Lynx (formerly the X-ray Surveyor), the Large UV/Optical/Infrared Surveyor (LUVOIR) and the Habitable Exoplanet Imager (HabEx). One of the key scientific objectives of the latter two is the detection and characterization of the earth-like planets around nearby stars using the direct imaging technique (along with a broad range of investigations regarding the architecture of and atmospheric composition exoplanetary systems using this technique). As a consequence dedicated exoplanet instruments are being studied for these mission concepts. This paper discusses the design of the coronagraph instrument for the architecture "A" (15 meters aperture) of LUVOIR. The material presented in this paper is aimed at providing an overview of the LUVOIR coronagraph instrument. It is the result of four months of discussions with various community stakeholders (scientists and technologists) regarding the instrument's basic parameters followed by meticulous design work by the the GSFC Instrument Design Laboratory team. In the first section we review the main science drivers, presents the overall parameters of the instrument (general architecture and backend instrument) and delve into the details of the currently envisioned coronagraph masks along with a description of the wavefront control architecture. Throughout the manuscript we describe the trades we made during the design process. Because the vocation of this study is to provide a baseline design for the most ambitious earth-like finding instrument that could be possibly launched into the 2030's, we have designed an complex system privileged that meets the ambitious science goals out team was chartered by the LUVOIR STDT exoplanet Working Group. However in an effort to minimize technological risk we tried

  12. VIRUS instrument collimator assembly

    Science.gov (United States)

    Marshall, Jennifer L.; DePoy, Darren L.; Prochaska, Travis; Allen, Richard D.; Williams, Patrick; Rheault, Jean-Philippe; Li, Ting; Nagasawa, Daniel Q.; Akers, Christopher; Baker, David; Boster, Emily; Campbell, Caitlin; Cook, Erika; Elder, Alison; Gary, Alex; Glover, Joseph; James, Michael; Martin, Emily; Meador, Will; Mondrik, Nicholas; Rodriguez-Patino, Marisela; Villanueva, Steven; Hill, Gary J.; Tuttle, Sarah; Vattiat, Brian; Lee, Hanshin; Chonis, Taylor S.; Dalton, Gavin B.; Tacon, Mike

    2014-07-01

    The Visual Integral-Field Replicable Unit Spectrograph (VIRUS) instrument is a baseline array 150 identical fiber fed optical spectrographs designed to support observations for the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX). The collimator subassemblies of the instrument have been assembled in a production line and are now complete. Here we review the design choices and assembly practices used to produce a suite of identical low-cost spectrographs in a timely fashion using primarily unskilled labor.

  13. Maintenance of scientific instruments

    International Nuclear Information System (INIS)

    Lucero, E.

    1986-01-01

    During the last years Colombia has increased the use of nuclear techniques, instruments and equipment in ambitious health programs, as well as in research centers, industry and education; this has resulted in numerous maintenance problems. As an alternative solution IAN has established a Central Maintenance Laboratory for nuclear instruments within an International Atomic Energy Agency program for eight Latin American and nine Asian Countries. Established strategies and some results are detailed in this writing

  14. Future of radiological instrumentation

    International Nuclear Information System (INIS)

    Lucas, A.C.

    1988-01-01

    Future trends in the development of radiation protection instrumentation can be expected to be closely related to current trends in political and social activity that drive legislation, rule-making, and standard practice, with assistance provided by trends in material and electronic technology. Wide-range performance will be emphasized to arm the daily worker with instruments that routinely log background rates and, at the same time, are prepared to measure accident rates. Separate and simultaneous accumulation of data from several sensors to ensure complete coverage of the radiation types will be common. Mathematical manipulation of data will provide for summary data logging and, in some cases, solutions to integral equations to provide corrections to experimental data. Instruments will become more reliable by way of self-checking and correction. Miniaturization and large-scale integration of measuring instruments will provide some instrumentation for the people at large. To be effective, the instruments will necessarily cover a wide range and be very reliable. The net result of these several trends will provide for a widespread understanding of radiation protection and an implementation of as low as reasonably achievable among large segments of the population

  15. [The instrument for thermography].

    Science.gov (United States)

    Hamaguchi, Shinsuke

    2014-07-01

    Thermography is an imaging method using the instrument to detect infrared rays emitted from the body surface, and to plot them as a distribution diagram of the temperature information. Therefore, a thermographic instrument can be assumed to measure the skin temperature of the diseased region. Such an instrument is a useful device for noninvasive and objective assessment of various diseases. Examination using a thermographic instrument can assess the autonomic dysfunction by measuring the skin blood flow involved with the sympathetic innervation. Thermography is useful in assisting the determination of the therapeutic effect. However, autonomic dysfunction should be confirmed correctly with the assessment of thermatome that shows abnormal thermal distribution in the region of the disease. Thermography should make noticeable the difference between the body temperature of abnormal and normal sites, and show the alteration of temperature. Monitoring using thermography is useful to determine the effect of sympathetic nerve block. If a thermographic instrument is used, it is important that examiners should understand the function of the instrument, as well as its advantages and disadvantages.

  16. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  17. Plane and geodetic surveying

    CERN Document Server

    Johnson, Aylmer

    2014-01-01

    IntroductionAim And ScopeClassification Of SurveysThe Structure Of This BookGeneral Principles Of SurveyingErrorsRedundancyStiffnessAdjustmentPlanning And Record KeepingPrincipal Surveying ActivitiesEstablishing Control NetworksMappingSetting OutResectioningDeformation MonitoringAngle MeasurementThe Surveyor's CompassThe ClinometerThe Total StationMaking ObservationsChecks On Permanent AdjustmentsDistance MeasurementGeneralTape MeasurementsOptical Methods (Tachymetry)Electromagnetic Distance Measurement (EDM)Ultrasonic MethodsGNSSLevellingTheoryThe InstrumentTechniqueBookingPermanent Adjustmen

  18. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  19. Instrumentation for environmental monitoring

    International Nuclear Information System (INIS)

    McLaughlin, R.D.; Hunt, M.S.; Murphy, D.L.; Chen, C.R.

    1979-06-01

    In the last few years a much greater emphasis has been placed upon understanding, controlling and monitoring the environmental effects of the advancing technologies. This has resulted in rapid advances in techniques for environmental monitoring. To aid the concerned scientist in keeping abreast of these developments, the Lawrence Berkeley Laboratory publishes a collection of volumes entitled Instrumentation for Environmental Monitoring. Separated into four volumes covering four media, AIR, WATER, RADIATION, and BIOMEDICAL, they provide a source book for three types of material: (1) Monitoring Rationale. They describe the characteristics, forms, and effects of a wide variety of pollutants and the means of controlling them. Federal regulations are explained and summarized. (2) Analytical Techniques. Methods of determining specific pollutants are described with special emphasis on the principles that form the basis of instrumental methods. (3) Commercial Instrumentation. The features of most commercially available instrumentation used for the determination and monitoring of each pollutant are presented in a manner that facilitates instrumental comparisons. Examples of the types of material in the volumes and the use of the volumes are presented

  20. Biochemistry Instrumentation Core Technology Center

    Data.gov (United States)

    Federal Laboratory Consortium — The UCLA-DOE Biochemistry Instrumentation Core Facility provides the UCLA biochemistry community with easy access to sophisticated instrumentation for a wide variety...

  1. Heat Flux Instrumentation Laboratory (HFIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: The Heat Flux Instrumentation Laboratory is used to develop advanced, flexible, thin film gauge instrumentation for the Air Force Research Laboratory....

  2. Research and Development on a Public Attitude Instrument for Stuttering

    Science.gov (United States)

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  3. Construct validation of an instrument to measure patient satisfaction ...

    African Journals Online (AJOL)

    Methods: The questionnaire was a 35–item inventory titled “Patient Satisfaction Survey (PSS)”. This study was carried out in three university teaching hospitals located in Southwestern Nigeria. The patient satisfaction survey instrument (PSS) was administered on 506 clinic outpatients who patronised the hospital ...

  4. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  5. Instrumentation Video Systems

    Science.gov (United States)

    Lida, Hitoshi

    1981-10-01

    The use of video equipment as instrumentation has been increasing steadily over the past decade. An indication of this trend can be found close to home: notice how rapidly the number of television (TV) displays has grown at our technical exhibits. It is this exhibited equipment and other equipment like it which form the subject of this summary. We will limit our discussions to readily available hardware (and a little software) and leave reports of the leading edge development work to other issues of this journal. We hope, in this manner, to present useful information to those who need to apply video to their instrumen-tation problems now. Along the way we will occasionally indicate what equipment might soon result from current research, but our clear emphasis will be on the state of the art of accessible instrumentation video.

  6. The IKARUS instrument

    International Nuclear Information System (INIS)

    Gerster, H.J.; Stein, G.

    1994-01-01

    When the Federal Government decided on a 25% reduction of CO 2 emissions till 2005 in 1990 the necessity resulted that an instrument has to be developed for the analysis and assessment of the ecological, economic and energetic impact of different reduction strategies. The development task was awarded by the BMFT to the Research Centre Juelich in cooperation with well-known institutions of energy system research. The total instrument is scheduled to be finished by the end of 1994. For the decentral use of the instrument by a wide specialist public the developed models and data banks which are equipped with a user-friendly surface are suited for larger PCs (486, 16 MB RAM/500-1000 MB ROM). (orig.) [de

  7. Calibration of Geodetic Instruments

    Directory of Open Access Journals (Sweden)

    Marek Bajtala

    2005-06-01

    Full Text Available The problem of metrology and security systems of unification, correctness and standard reproducibilities belong to the preferred requirements of theory and technical practice in geodesy. Requirements on the control and verification of measured instruments and equipments increase and the importance and up-to-date of calibration get into the foreground. Calibration possibilities of length-scales (of electronic rangefinders and angle-scales (of horizontal circles of geodetic instruments. Calibration of electronic rangefinders on the linear comparative baseline in terrain. Primary standard of planar angle – optical traverse and its exploitation for calibration of the horizontal circles of theodolites. The calibration equipment of the Institute of Slovak Metrology in Bratislava. The Calibration process and results from the calibration of horizontal circles of selected geodetic instruments.

  8. Aethalometer™ Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, Arthur J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

  9. ISSUERS OF FINANCIAL INSTRUMENTS

    Directory of Open Access Journals (Sweden)

    Cristian GHEORGHE

    2016-05-01

    Full Text Available The rules laid down by Romanian Capital Market Law and the regulations put in force for its implementation apply to issuers of financial instruments admitted to trading on the regulated market established in Romania. But the issuers remain companies incorporated under Company Law of 1990. Such dual regulations need increased attention in order to observe the legal status of the issuers/companies and financial instruments/shares. Romanian legislator has chosen to implement in Capital Market Law special rules regarding the administration of the issuers of financial instruments, not only rules regarding admitting and maintaining to a regulated market. Thus issuers are, in Romanian Law perspective, special company that should comply special rule regarding board of administration and general shareholders meeting.

  10. Swift Burst Alert Telescope (BAT) Instrument Response

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Hullinger, D.; Krimm, H.; Markwardt, C.; Tueller, J.; Fenimore, E.; Palmer, D.; Sato, G.; Takahashi, T.; Nakazawa, K.; Okada, Y.; Takahashi, H.; Suzuki, M.; Tashiro, M.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts, and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. This paper describes the spectral models and the ground calibration experiments used to determine the BAT response to an accuracy suitable for gamma-ray burst studies

  11. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  12. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  13. Standard NIM instrumentation system

    CERN Document Server

    1990-01-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID- 20893 (Rev 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice.

  14. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  15. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  16. Frailty assessment instruments: Systematic characterization of the uses and contexts of highly-cited instruments

    Science.gov (United States)

    Buta, Brian J.; Walston, Jeremy D.; Godino, Job G.; Park, Minsun; Kalyani, Rita R.; Xue, Qian-Li; Bandeen-Roche, Karen; Varadhan, Ravi

    2016-01-01

    The medical syndrome of frailty is widely recognized, yet debate remains over how best to measure it in clinical and research settings. This study reviewed the frailty-related research literature by (a) comprehensively cataloging the wide array of instruments that have been utilized to measure frailty, and (b) systematically categorizing the different purposes and contexts of use for frailty instruments frequently cited in the research literature. We identified 67 frailty instruments total; of these, nine were highly-cited (≥200 citations). We randomly sampled and reviewed 545 English-language articles citing at least one highly-cited instrument. We estimated the total number of uses, and classified use into eight categories: risk assessment for adverse health outcomes (31% of all uses); etiological studies of frailty (22%); methodology studies (14%); biomarker studies (12%); inclusion/exclusion criteria (10%); estimating prevalence as primary goal (5%); clinical decision-making (2%); and interventional targeting (2%). The most common assessment context was observational studies of older community-dwelling adults. Physical Frailty Phenotype was the most used frailty instrument in the research literature, followed by the Deficit Accumulation Index and the Vulnerable Elders Survey. This study provides an empirical evaluation of the current uses of frailty instruments, which may be important to consider when selecting instruments for clinical or research purposes. We recommend careful consideration in the selection of a frailty instrument based on the intended purpose, domains captured, and how the instrument has been used in the past. Continued efforts are needed to study the validity and feasibility of these instruments. PMID:26674984

  17. Integrating Nephelometer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Uin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

  18. AC resistance measuring instrument

    Science.gov (United States)

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  19. Measurement and Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, Harold

    2018-01-02

    This is a chapter for a book called the Standard Handbook for Electrical Engineering. Though it is not obvious from the title, the book deals mainly with power engineering. The first chapter (not mine) is about the fundamental quantities used in measurement. This chapter is about the process and the instrumentation.

  20. Instruments for Everyone.

    Science.gov (United States)

    Perkins-Bosarge, Sarah

    1998-01-01

    Thanks to an entrepreneurial principal, nearly 75% of a rural New York State school's upper-division students participate in band. To ensure access, the principal bargains with second-hand dealers for instruments (using fees from photo profits) and charges kids a fee of $1 to $15 yearly. Consulting with the music teacher avoids duplication and…

  1. Economic Policy Instruments

    DEFF Research Database (Denmark)

    Klemmensen, Børge

    2007-01-01

    Økonomiske instrumenter begrundes med behovet for politiske indgreb, der muliggør internaliseringen af omkostningerne ved de miljøpåvirkninger, produktion and levevis afstedkommer, således at hensyntagen til miljøet bliver en del af virksomheders og husholdningers omkostninger og dermed en tilsky...

  2. Designing Intelligent Instruments

    Science.gov (United States)

    Knuth, Kevin H.; Erner, Philip M.; Frasso, Scott

    2007-11-01

    Remote science operations require automated systems that can both act and react with minimal human intervention. One such vision is that of an intelligent instrument that collects data in an automated fashion, and based on what it learns, decides which new measurements to take. This innovation implements experimental design and unites it with data analysis in such a way that it completes the cycle of learning. This cycle is the basis of the Scientific Method. The three basic steps of this cycle are hypothesis generation, inquiry, and inference. Hypothesis generation is implemented by artificially supplying the instrument with a parameterized set of possible hypotheses that might be used to describe the physical system. The act of inquiry is handled by an inquiry engine that relies on Bayesian adaptive exploration where the optimal experiment is chosen as the one which maximizes the expected information gain. The inference engine is implemented using the nested sampling algorithm, which provides the inquiry engine with a set of posterior samples from which the expected information gain can be estimated. With these computational structures in place, the instrument will refine its hypotheses, and repeat the learning cycle by taking measurements until the system under study is described within a pre-specified tolerance. We will demonstrate our first attempts toward achieving this goal with an intelligent instrument constructed using the LEGO MINDSTORMS NXT robotics platform.

  3. The tropospheric monitoring instrument

    NARCIS (Netherlands)

    Voert, M.J. te; Brakel, R. van; Witvoet, G.

    2014-01-01

    Thermal and opto-mechanical design and analysis work has been done on the Tropospheric Monitoring Instrument (TROPOMI), a spectrometer on the Copernicus Sentinel 5 Precursor satellite. To verify compliance with the stringent opto-mechanical stability requirements, detailed thermal and

  4. University Reactor Instrumentation Program

    International Nuclear Information System (INIS)

    Vernetson, W.G.

    1992-11-01

    Recognizing that the University Reactor Instrumentation Program was developed in response to widespread needs in the academic community for modernization and improvement of research and training reactors at institutions such as the University of Florida, the items proposed to be supported by this grant over its two year period have been selected as those most likely to reduce foreed outages, to meet regulatory concerns that had been expressed in recent years by Nuclear Regulatory Commission inspectors or to correct other facility problems and limitations. Department of Energy Grant Number DE-FG07-90ER129969 was provided to the University of Florida Training Reactor(UFTR) facility through the US Department of Energy's University Reactor Instrumentation Program. The original proposal submitted in February, 1990 requested support for UFTR facility instrumentation and equipment upgrades for seven items in the amount of $107,530 with $13,800 of this amount to be the subject of cost sharing by the University of Florida and $93,730 requested as support from the Department of Energy. A breakdown of the items requested and total cost for the proposed UFTR facility instrumentation and equipment improvements is presented

  5. Analytical chemistry instrumentation

    International Nuclear Information System (INIS)

    Laing, W.R.

    1986-01-01

    Separate abstracts were prepared for 48 papers in these conference proceedings. The topics covered include: analytical chemistry and the environment; environmental radiochemistry; automated instrumentation; advances in analytical mass spectrometry; Fourier transform spectroscopy; analytical chemistry of plutonium; nuclear analytical chemistry; chemometrics; and nuclear fuel technology

  6. Advanced instrumentation and teleoperation

    International Nuclear Information System (INIS)

    Decreton, M.

    1998-01-01

    SCK-CEN's advanced instrumentation and teleoperation project aims at evaluating the potential of a telerobotic approach in a nuclear environment and, in particular, the use of remote-perception systems. Main achievements in 1997 in the areas of R and D on radiation tolerance for remote sensing, optical fibres and optical-fibre sensors, and computer-aided teleoperation are reported

  7. Analytical chemistry instrumentation

    International Nuclear Information System (INIS)

    Laing, W.R.

    1986-01-01

    In nine sections, 48 chapters cover 1) analytical chemistry and the environment 2) environmental radiochemistry 3) automated instrumentation 4) advances in analytical mass spectrometry 5) fourier transform spectroscopy 6) analytical chemistry of plutonium 7) nuclear analytical chemistry 8) chemometrics and 9) nuclear fuel technology

  8. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  9. netherland hydrological modeling instrument

    Science.gov (United States)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    Netherlands Hydrological Modeling Instrument A decision support system for water basin management. J.C. Hoogewoud , W.J. de Lange ,A. Veldhuizen , G. Prinsen , The Netherlands Hydrological modeling Instrument (NHI) is the center point of a framework of models, to coherently model the hydrological system and the multitude of functions it supports. Dutch hydrological institutes Deltares, Alterra, Netherlands Environmental Assessment Agency, RWS Waterdienst, STOWA and Vewin are cooperating in enhancing the NHI for adequate decision support. The instrument is used by three different ministries involved in national water policy matters, for instance the WFD, drought management, manure policy and climate change issues. The basis of the modeling instrument is a state-of-the-art on-line coupling of the groundwater system (MODFLOW), the unsaturated zone (metaSWAP) and the surface water system (MOZART-DM). It brings together hydro(geo)logical processes from the column to the basin scale, ranging from 250x250m plots to the river Rhine and includes salt water flow. The NHI is validated with an eight year run (1998-2006) with dry and wet periods. For this run different parts of the hydrology have been compared with measurements. For instance, water demands in dry periods (e.g. for irrigation), discharges at outlets, groundwater levels and evaporation. A validation alone is not enough to get support from stakeholders. Involvement from stakeholders in the modeling process is needed. There fore to gain sufficient support and trust in the instrument on different (policy) levels a couple of actions have been taken: 1. a transparent evaluation of modeling-results has been set up 2. an extensive program is running to cooperate with regional waterboards and suppliers of drinking water in improving the NHI 3. sharing (hydrological) data via newly setup Modeling Database for local and national models 4. Enhancing the NHI with "local" information. The NHI is and has been used for many

  10. The Measurement of Sexual Harassment: Comparison of the Results of Three Different Instruments

    NARCIS (Netherlands)

    Junger, Marianne

    1990-01-01

    This study examines the results of three instruments developed to measure sexual harassment. Two instruments were used in the Dutch national victimization survey: an oral interview and a written questionnaire. Three issues will be discussed: (1) do both instruments produce the same victimization

  11. A Life in the Universe Survey

    Science.gov (United States)

    LoPresto, Michael C.; Hubble-Zdanowski, Jennifer

    2012-01-01

    The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…

  12. The UVISI instrument.

    Science.gov (United States)

    Heffernan, K. J.; Heiss, J. E.; Boldt, J. D.; Darlington, E. H.; Peacock, K.; Harris, T. J.; Mayr, M. J.

    1996-06-01

    The Ultraviolet and Visible Imagers and Spectrographic Imagers (UVISI) instrument is a complex of nine sensor units (five spectrographic imagers and four imagers) and multiple processors that will provide detailed images and spectra of targets for the Midcourse Space Experiment mission. Imaging and spectroscopy each cover the range from 110 nm (far ultraviolet) to 900 nm (near infrared). UVISI is intended to investigate a multitude of celestial, atmospheric, and point sources over its planned 4-year lifetime. At 104 W and 211 kg, it is not only the largest free-flying instrument ever built at APL, but is also larger than 47 of the 55 APL-built spacecraft and more complex than many of them. This article discusses the specifications of UVISI and its hardware and software features. It also attempts to give the reader a sense of the design trade-offs made during UVISI development that resulted in its present configuration.

  13. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  14. Superfluid helium tanker instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Woodhouse, C.E. (Johns Hopkins Univ., Baltimore, MD (USA). School of Medicine); Kashani, A. (Sterling Federal Systems, Inc., NASA/Ames Research Center, Moffett Field, CA (US)); Lukemire, A.T. (National Aeronautics and Space Administration, Greenbelt, MD (USA). Goddard Space Flight Center)

    1990-02-01

    An instrumentation system for a 1992 space shuttle flight demonstration of a superfluid helium (SFHe) tanker and transfer technology is presented. This system provides measurement of helium temperatures, pressures, flow rates, mass, and the presence of liquid or vapor. The instrumentation system described consists of analog and digital portions which provide a space qualified electronics system that is fault tolerant, compact, and relatively lightweight. The data processing hardware and software are ground commandable, perform measurements asynchronously, and format telemetry for transmission to the ground. The novel heat pulse mass gaging technique is described. A new liquid/vapor sensor is presented. Flowmeters for SFHe are discussed. A SFHe fountain effect pump is described. Results of tests to date are presented.

  15. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...... overview of VRMIs from the viewpoint of the performer. We propose nine design guidelines, describe evaluation methods, analyze case studies, and consider future challenges....

  16. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  17. Instrumentation Engineers Handbook

    Science.gov (United States)

    2013-01-01

    White Sands Missile Range New Mexico 88002-5110 This page intentionally left blank. Instrumentation Engineers Handbook, RCC Document 121-13...Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White Sands Missile Range, New Mexico 88002-5110 Telephone: (575) 678-1107...multiplying that by the C/D ratio, where C is a dimensional constant and D is density: ( ) D PPC V Tpp − = Eqn. 5-8 When the flow rate is obtained by

  18. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  19. Virtual reality musical instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low cost technologies has created a wide interest in virtual reality (VR), but how to design and evaluate multisensory interactions in VR remains as a challenge. In this paper, we focus on virtual reality musical instruments, present an overview of our...... design and evaluation guidelines, and examine historical case studies. Our main contribution is to inform the design and evaluation of the future VRMIs and consider the challenges....

  20. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1976-01-01

    Reference is made to the instrumentation of liquid metal cooled fast reactors. In order to ensure the safe operation of such reactors it is necessary to constantly monitor the coolant flowing through the fuel assemblies for temperature and rate of flow, requiring a large number of sensors. An improved and simplified arrangement is claimed in which the fuel assemblies feed a fraction of coolant to three instrument units arranged to sense the temperature and rate of flow of samples of coolant. Each instrument unit comprises a sleeve housing a sensing unit and has a number of inlet ducts arranged for receiving coolant from a fuel assembly together with a single outlet. The sensing unit has three thermocouple hot junctions connected in series, the hot junctions and inlet ducts being arranged in pairs. Electromagnetic windings around an inductive core are arranged to sense variation in flow of liquid metal by flux distortion. Fission product sensing means may also be provided. Full constructional details are given. (U.K.)

  1. Instrumentation and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Nakaishi, C.V.; Bedick, R.C.

    1990-12-01

    This Technology Status Report describes research and accomplishments for the Instrumentation and Diagnostics (I D) Projects within the Advanced Research and Technology Development (AR TD) Program of the United States Department of Energy (DOE) Office of Fossil Energy (FE). Process understanding and control can be improved through the development of advanced instrumentation and diagnostics. The thrust of the I D Projects is to further develop existing measurement and control techniques for application to advanced coal-based technologies. Project highlights are: an inductively coupled plasma (ICP) instrument has been developed to analyze trace elements in gasification and combustion process streams. An in situ two-color Mie scattering technique with LSS can simultaneously measure the size, velocity, and elemental composition of coal particles during combustion. A high-temperature, fluorescence thermometry technique has accurately measured gas temperatures during field testing in combustion and gasification environments. Expert systems have been developed to improve the control of advanced coal-based processes. Capacitance flowmeters were developed to determine the mass flowrate, solid volume fraction, and particle velocities of coal slurries. 32 refs., 9 figs.

  2. Mandolin Family Instruments

    Science.gov (United States)

    Cohen, David J.; Rossing, Thomas D.

    The mandolin family of instruments consists of plucked chordophones, each having eight strings in four double courses. With the exception of the mandobass, the courses are tuned in intervals of fifths, as are the strings in violin family instruments. The soprano member of the family is the mandolin, tuned G3-D4-A4-E5. The alto member of the family is the mandola, tuned C3-G3-D4-A4. The mandola is usually referred to simply as the mandola in the USA, but is called the tenor mandola in Europe. The tenor member of the family is the octave mandolin, tuned G2-D3-A3-E4. It is referred to as the octave mandolin in the USA, and as the octave mandola in Europe. The baritone member of the family is the mandocello, or mandoloncello, tuned C2-G2-D3-A3. A variant of the mandocello not common in the USA is the five-course liuto moderno, or simply liuto, designed for solo repertoire. Its courses are tuned C2-G2-D3-A3-E4. A mandobass was also made by more than one manufacturer during the early twentieth century, though none are manufactured today. They were fretted instruments with single string courses tuned E1-A1-D2-G2. There are currently a few luthiers making piccolo mandolins, tuned C4-G4-D5-A5.

  3. FHR Process Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David Eugene [ORNL

    2015-01-01

    Fluoride salt-cooled High temperature Reactors (FHRs) are entering into early phase engineering development. Initial candidate technologies have been identified to measure all of the required process variables. The purpose of this paper is to describe the proposed measurement techniques in sufficient detail to enable assessment of the proposed instrumentation suite and to support development of the component technologies. This paper builds upon the instrumentation chapter of the recently published FHR technology development roadmap. Locating instruments outside of the intense core radiation and high-temperature fluoride salt environment significantly decreases their environmental tolerance requirements. Under operating conditions, FHR primary coolant salt is a transparent, low-vapor-pressure liquid. Consequently, FHRs can employ standoff optical measurements from above the salt pool to assess in-vessel conditions. For example, the core outlet temperature can be measured by observing the fuel s blackbody emission. Similarly, the intensity of the core s Cerenkov glow indicates the fission power level. Short-lived activation of the primary coolant provides another means for standoff measurements of process variables. The primary coolant flow and neutron flux can be measured using gamma spectroscopy along the primary coolant piping. FHR operation entails a number of process measurements. Reactor thermal power and core reactivity are the most significant variables for process control. Thermal power can be determined by measuring the primary coolant mass flow rate and temperature rise across the core. The leading candidate technologies for primary coolant temperature measurement are Au-Pt thermocouples and Johnson noise thermometry. Clamp-on ultrasonic flow measurement, that includes high-temperature tolerant standoffs, is a potential coolant flow measurement technique. Also, the salt redox condition will be monitored as an indicator of its corrosiveness. Both

  4. Developments in the use of economic instruments in OECD countries

    International Nuclear Information System (INIS)

    Opschoor, H.

    1994-01-01

    For the period 1987-1993, developments in the environmental policies of OECD countries with respect to the use of economic instruments are compared and the differences analyzed. The focus is on applications in the field of air pollution policies. The comparison is made on the basis of two surveys. To complete the descriptive part, a brief survey is also presented of currently discussed and recently introduced economic instruments. A description of economic instruments as such and a review of rationales for employing economic and financial incentives precede this analysis. The analysis shows that the use of economic instruments has indeed increased since 1987, but the development has not been spectacular. Possible explanations for this are presented. Also, some types of instrument have advanced more than others and the changes differ from one set of countries to another. Product charges (including air pollution-related ones) have become more widely used, especially in Scandinavian countries. Moreover, growing attention is being paid to the use of economic instruments at the international level. The incentive impacts of economic (and other) instruments appear to have received relatively little empirical attention, even though these are an important policy-relevant feature in instrument choice. 23 refs., 5 tabs

  5. Ninth Triennial Toxicology Salary Survey.

    Science.gov (United States)

    Gad, Shayne Cox; Sullivan, Dexter Wayne

    2016-01-01

    This survey serves as the ninth in a series of toxicology salary surveys conducted at 3-year intervals and beginning in 1988. An electronic survey instrument was distributed to 5919 individuals including members of the Society of Toxicology, American College of Toxicology, and 23 additional professional organizations. Question items inquired about gender, age, degree, years of experience, certifications held, areas of specialization, society membership, employment and income. Overall, 1293 responses were received (response rate 21.8%). The results of the 2014 survey provide insight into the job market and career path for current and future toxicologists. © The Author(s) 2016.

  6. Status of ART-XC/SRG instrument

    Science.gov (United States)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Krivchenko, A.; Rotin, A.; Kuznetsova, M.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; Grebenev, S.; Sazonov, S.; Revnivtsev, M.; Lutovinov, A.; Molkov, S.; Krivonos, R.; Serbinov, D.; Kudelin, M.; Drozdova, T.; Voronkov, S.; Sunyaev, R.; Churazov, E.; Gilfanov, M.; Babyshkin, V.; Lomakin, I.; Menderov, A.; Gubarev, M.; Ramsey, B.; Kilaru, K.; O'Dell, S. L.; Kolodziejczak, J.; Elsner, R.; Zavlin, V.; Swartz, D.

    2016-07-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in 2017 from Baikonur and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescope arrays - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The ART-XC flight mirror modules have been developed and fabricated at the NASA Marshall Space Flight Center (MSFC). Each mirror module will be aligned with a focal plane CdTe double-sided strip detector which will operate over the energy range of 6-30 keV, with an angular resolution of <1', a field of view of 34' and an expected energy resolution of about 12% at 14 keV. The current status of the ART-XC/SRG instrument is presented here.

  7. ZBLAN Viscosity Instrumentation

    Science.gov (United States)

    Kaukler, William

    2001-01-01

    The past year's contribution from Dr. Kaukler's experimental effort consists of these 5 parts: a) Construction and proof-of-concept testing of a novel shearing plate viscometer designed to produce small shear rates and operate at elevated temperatures; b) Preparing nonlinear polymeric materials to serve as standards of nonlinear Theological behavior; c) Measurements and evaluation of above materials for nonlinear rheometric behavior at room temperature using commercial spinning cone and plate viscometers available in the lab; d) Preparing specimens from various forms of pitch for quantitative comparative testing in a Dynamic Mechanical Analyzer, Thermal Mechanical Analyzer; and Archeological Analyzer; e) Arranging to have sets of pitch specimens tested using the various instruments listed above, from different manufacturers, to form a baseline of the viscosity variation with temperature using the different test modes offered by these instruments by compiling the data collected from the various test results. Our focus in this project is the shear thinning behavior of ZBLAN glass over a wide range of temperature. Experimentally, there are no standard techniques to perform such measurements on glasses, particularly at elevated temperatures. Literature reviews to date have shown that shear thinning in certain glasses appears to occur, but no data is available for ZBLAN glass. The best techniques to find shear thinning behavior require the application of very low rates of shear. In addition, because the onset of the thinning behavior occurs at an unknown elevated temperature, the instruments used in this study must provide controlled low rates of shear and do so for temperatures approaching 600 C. In this regard, a novel shearing parallel plate viscometer was designed and a prototype built and tested.

  8. Diamonds for beam instrumentation

    International Nuclear Information System (INIS)

    Griesmayer, Erich

    2013-01-01

    Diamond is perhaps the most versatile, efficient and radiation tolerant material available for use in beam detectors with a correspondingly wide range of applications in beam instrumentation. Numerous practical applications have demonstrated and exploited the sensitivity of diamond to charged particles, photons and neutrons. In this paper, a brief description of a generic diamond detector is given and the interaction of the CVD diamond detector material with protons, electrons, photons and neutrons is presented. Latest results of the interaction of sCVD diamond with 14 MeV mono-energetic neutrons are shown.

  9. Biomagnetic instrumentation and measurement

    Science.gov (United States)

    Iufer, E. J.

    1978-01-01

    The instruments and techniques of biomagnetic measurement have progressed greatly in the past 15 years and are now of a quality appropriate to clinical applications. The paper reports on recent developments in the design and application of SQUID (Superconducting Quantum Interference Device) magnetometers to biomagnetic measurement. The discussion covers biomagnetic field levels, magnetocardiography, magnetic susceptibility plethysmography, ambient noise and sensor types, principles of operation of a SQUID magnetometer, and laboratory techniques. Of the many promising applications of noninvasive biomagnetic measurement, magnetocardiography is the most advanced and the most likely to find clinical application in the near future.

  10. Maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Oliveira Rebelo, A.M. de; Santos, C.J.F. dos; Jesus, E.F.O. de; Silva, L.E.M.C.; Borges, J.C.

    1988-01-01

    A program to design and repairing of nuclear instruments for teaching and research was founded in the UFRJ to find solutions for technical support problem - The GEMD-RADIACOES. This group has assisted to several groups of the University in recuperation and conservation of devices like: Linear scanner, Cromatograph and system of radiation detection in general. Recuperation of these devices had required a study of theirs operations modes, to make it possible the setting up of a similar system. Recuperation also involves operation tests, calibration and technical for users, orienting them to get the best performance. (Author) [pt

  11. Payment Instrument Characteristics

    DEFF Research Database (Denmark)

    Holst, Jacques; Kjeldsen, Martin; Hedman, Jonas

    2015-01-01

    Over the last decade, we have witnessed payment innovations that fundamentally have changed the ways we pay. Payment innovations, such as mobile payments and on-line banking, include characteristics or features that are essential to understand if we want to know how and why payers choose among...... payment innovations. Using the Repertory Grid technique to explore 15 payers’ perception of six payment instruments, including coins, banknotes, debit cards, credit cards, mobile payments, and on-line banking, we identify 16 payment characteristics. The characteristics aggregate seventy-six unique...

  12. Instrumentation for tomograph positioning

    International Nuclear Information System (INIS)

    Frenkel, A.D.B.; Castello Branco, L.M.; Reznik, D.S.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The COPPE's Nuclear Instrumentation Lab. has been developing researches directed towards the implementation of a Computer-Based Tomography System. Basically, the system reported in this paper can be divided into three major parts: the mechanical part, responsible for the physical movement (Stepper-Motors, table, etc.); the electronic part, which controls the mechanical part and handles the data-acquisition process (microcomputer, interfaces, etc.); and finally, the support of a software-oriented system, including control programs and information processing routines. (Author) [pt

  13. Pesticide reducing instruments

    DEFF Research Database (Denmark)

    Jacobsen, Lars-Bo; Jensen, Jørgen Dejgård; Andersen, Martin

    2005-01-01

    of a key species of farmland bird, caused to changes in production and landscape. The results from the agricultural sector model are also used in evaluation of pesticide usage and the leaching of pesticides to ground water. First we analyze the implication of three different scenarios in all of the above...... for improving bio-diversity and securing drinking water. That is, combining economic modeling with physical biological modeling and geological evaluation allows us to select unsprayed field margins as the most effective instrument. Sensitivity analysis conducted on bio-diversity suggest that this result...

  14. Leir beam instrumentation

    CERN Document Server

    Bal, C; Burger, S; Dutriat, C; Gasior, M; Lefèvre, T; Lenardon, F; Odier, P; Raich, U; Soby, L; Tan, J; Tranquille, G; Vuitton, C

    2005-01-01

    The Low Energy Ion Ring (LEIR) is central to the “Ions for LHC” project. Its role is to transform a serie of long low intensity ion pulses from Linac 3, into short high density pulses, which will be further accelerated in the PS and SPS rings, before injection into LHC. To do so the injected pulses are stacked and phase space cooled using electron cooling, before acceleration to the ejection energy of 72 MEV/u. This note describes different types of instruments which will be installed in the LEIR ring and transfer lines.

  15. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  16. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  17. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  18. Calibration philosophy for reactor instrumentation

    International Nuclear Information System (INIS)

    Saroja, A.R.; Ilango Sambasivan, S.; Swaminathan, P.

    2004-01-01

    All electronic test and measuring systems and process control instruments constitute a critical and important area of instrumentation in the nuclear and conventional power plant, process plant and research laboratories. All these instruments need periodic calibration. Therefore standards laboratories is one of the essential tools in enforcing quality. Calibration of these instruments plays a vital role in the performance, reliability, and quality of the target to be achieved. Thus calibration is a must if need speed and quality. (author)

  19. PC Calibration of Measuring Instrument

    OpenAIRE

    Gold, Ayoola

    2015-01-01

    Calibration involves the adjustment of measuring instruments basically by comparing the values obtained from a measuring instrument with a standard instrument whose output value is known. This project is focused at developing an application used to calibrate measuring instruments (oscilloscope) in the laboratory. This application eases the traditional inputting of output value manually from the calibrator (Fluke 5500A in this case) to the oscilloscope (Agilent DSO5012A oscilloscope in this ca...

  20. UC Merced NMR Instrumentation Acquisition

    Science.gov (United States)

    2015-06-18

    UC Merced NMR Instrumentation Acquisition For the UC Merced NMR Instrumentation Acquisition proposal, a new 400 MHz and an upgraded 500 MHz NMR...valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. University of California - Merced 5200 North Lake Road Merced , CA 95343...UC Merced NMR Instrumentation Acquisition Report Title For the UC Merced NMR Instrumentation Acquisition proposal, a new 400 MHz and an upgraded 500

  1. Instrumento para la evaluación de variables psicológicas y comportamientos sexuales de riesgo en jóvenes de dos centros universitarios de México A survey instrument for evaluating psychological variables and risky sexual behavior among young adults at two university centers in Mexico

    Directory of Open Access Journals (Sweden)

    Julio A. Piña López

    2007-11-01

    diferentes variables históricas y de contexto contempladas y en su interacción.OBJECTIVES: To measure the psychometric attributes of a survey instrument designed to evaluate historical and context variables that lead to high-risk sexual behaviors among a sample of university students in Mexico. METHODS: Cross-sectional study of a sample of 1 346 university students in Mexico: 784 from the Sonora State Center for Higher Education in Hermosillo, Sonora, or 33.2% of its total enrollment; and 562 from the National Autonomous University of Mexico, at Tlalnepantla campus in Mexico State, or 23.5% of its total enrollment. The study took place in Hermosillo during the month of October 2006 and in Tlalnepantla from January to March 2006. The survey had 11 questions on sociodemographics, 7 on risky sexual behaviors, 22 on related motives, 8 on social context, and 6 on physical status prior to sexual relations. The survey was evaluated in terms of how well the questions were understood, its conceptual validity, and reliability. RESULTS: The final version of the survey instrument was composed of 44 questions. The reliability analysis produced an overall Cronbach a value of 0.821, taking into account all the variables combined and grouped by factor. Three factors were found that together accounted for 38.36% of the total variance: reasons for not using a condom in the first sexual relationship or throughout life, reasons for inconsistent use of a condom with a casual sex partner, and willingness to become sexually active and to engage in casual sex. CONCLUSIONS: The psychometric attributes of this survey instrument were found to be satisfactory. Those interested in using this instrument should become familiar with the theoretical model on which it is based, since understanding the results depends on properly defining the historical and context variables, and their interaction.

  2. Incore instrument device

    International Nuclear Information System (INIS)

    Sakima, Naoki

    1996-01-01

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  3. The QUIET Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bischoff, C.; et al.

    2012-07-01

    The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ({approx}1{sup o}). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0:1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0:01. The two arrays together cover multipoles in the range {ell} {approx} 25 -- 975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument.

  4. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  5. Rio de Janeiro: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Students from Latin America were able to get hands-on experience in state-of-the-art physics instrumentation in this year's School on Instrumentation for High Energy Physics organized by the active Instrumentation Panel of ICFA (the International Committee for Future Accelerators) at the Centro Brasileiro de Pesquicas Fisicas (CBPF), Rio de Janeiro, in July

  6. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  7. Nuclear instrumentation for radiation protection [Paper No.:N1

    International Nuclear Information System (INIS)

    Iyer, M.R.

    1993-01-01

    Instrumentation for radiation protection surveillance should be primarily geared to generate and process a complete set of data on the radiological status in and around the nuclear installations for controlling the internal and external exposure of workers and to ensure that the dose to members of the public are kept below the mandatory limits. The paper reviews the status of development of radiation protection instruments in the national context and projects the requirements. The various category of instruments discussed in the paper cover survey instruments, installed monitors, personal monitoring devices, neutron monitors, air monitoring instruments, environmental dose logging systems and detectors. The development efforts need to be translated into regular production with proper quality assurance for meeting the growing demands of the radiation protection profession in the country. (author). 30 refs

  8. Neural network signal understanding for instrumentation

    DEFF Research Database (Denmark)

    Pau, L. F.; Johansen, F. S.

    1990-01-01

    A report is presented on the use of neural signal interpretation theory and techniques for the purpose of classifying the shapes of a set of instrumentation signals, in order to calibrate devices, diagnose anomalies, generate tuning/settings, and interpret the measurement results. Neural signal...... understanding research is surveyed, and the selected implementation and its performance in terms of correct classification rates and robustness to noise are described. Formal results on neural net training time and sensitivity to weights are given. A theory for neural control using functional link nets is given......, and an explanation facility designed to help neural signal understanding is described. The results are compared to those obtained with a knowledge-based signal interpretation system using the same instrument and data...

  9. The Prospects of Musical Instruments For People with Physical Disabilities

    DEFF Research Database (Denmark)

    Larsen, Jeppe Veirum; Overholt, Daniel; Moeslund, Thomas B.

    2016-01-01

    Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions...... through therapeutic use. The field of musical instruments for people with physical disabilities, however, is still an emerging area of research. In this article, we look at the current state of developments, including a survey of custom designed instruments, augmentations / modifications of existing...

  10. Victimisation surveys: What are they good for?

    Directory of Open Access Journals (Sweden)

    Aromaa Kauko

    2012-01-01

    Full Text Available The author analyzes the usefulness of victimization surveys. The paper is focused of surveys in which nationally representative population samples are surveyed for their personal victimisation experiences, and their attitudes and opinions of issues related to crime and crime control. The author points out the benefits of using victimization surveys, but also explains why most countries have failed to make systematic use of this instrument.

  11. Principles of survey development for telemedicine applications.

    Science.gov (United States)

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  12. Astronomical Instrumentation System Markup Language

    Science.gov (United States)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  13. Instrumented Pipeline Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  14. FMIT diagnostic instrumentation

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Chamberlin, D.D.

    1985-01-01

    The Fusion Materials Irradiation Test facility (FMIT) cw prototype accelerator has noninterceptive beamline instrumentation to measure beam parameters. The transverse emittances and beam profiles are measured with an array of photodiode sensors viewing light emitted from the beam region. Tomographic reconstructions of both spatial-density distributions and of transverse-emittance distributions are performed throughout a quadrupole focusing section. Beam bunches passing through capacitive probes produce bipolar waveforms whose zero crossing corresponds to the bunch's longitudinal centroid. By measuring the time required for a bunch to travel the known distance between two probes, velocity and energy are determined. A toroidal transformer measures the average ac beam current. Beam spill is measured by a set of movable jaws that intercept the beam edges. Each jaw contains a water flow channel whose flow rate and differential temperature are measured to derive a transverse power distribution. Beam centroid position is measured by a four-lobe, magnetic-loop pickup. 5 refs., 6 figs

  15. Transgressive or Instrumental?

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2018-01-01

    Contemporary practices that connect the arts with learning are widespread at all level of educational systems and in organisations, but they include very diverse approaches, multiple methods and background values. Regardless of explicit learning benefits, the arts/learning partnerships bring about...... a specific approach to learning, which is embodied, sensory and aesthetic and makes use of metaphors, mediation, meaning-making and sense-making. I will make the point that the arts establish an alternative learning environment, which is different from the formal educational systems by offering multiple...... creativity and the other on practices of arts-integration. My final point rests on the belief that the opposition of transgression and instrumentality is a deceiving perspective on the arts, against the background of the aesthetic plurality and hybridity....

  16. Geophysical Survey as a useful Instrument for Determining ...

    African Journals Online (AJOL)

    The investigation of direct current probing of sea level for subsurface lithology in Igarra area of Edo State, Nigeria was carried out using electrical resistivity method based on schlumberger array of vertical electrical sounding (VES). The need to carry out this research became imperative in view of the fact that subsurface ...

  17. A Quality of Working Life Survey Instrument for Hospital Nurses.

    Science.gov (United States)

    Hsu, Ming-Yi

    2016-03-01

    The high turnover rate for hospital nurses worldwide means that some nursing staff remain at their posts for only a few months. To fully understand the problem, it is necessary to evaluate the concepts, constructs, and units of the working life of professional nurses. Previous qualitative work has identified and defined an initial set of items relevant to the working life of nurses. Therefore, the aim of this research is to develop a valid questionnaire for use in further examining the working life quality of nurses. This article reports on the development of a questionnaire that is valid and reliable for examining the quality of working life of nurses. Qualitative and quantitative data collection methods were employed within two medical centers and six regional hospitals in Taiwan. Seven hundred registered nurses in medical or surgical wards with at least 2 years of nursing experience and a position below assistant manager in a medical or surgical ward were included as participants. Previous qualitative research findings generated items for the questionnaire with content and construct. Six scales with 33 factors were identified. The scales addressed the aspects of organization, work, self-actualization, interrelationships, self-efficacy, and vocational concepts. These factors explained 63% of the total variance. The Cronbach's alphas ranged from .80 to .89, indicating acceptable internal consistency. The information obtained using the questionnaire may improve workplace audit outcomes, promote occupational health, and improve service quality.

  18. Survey on Johnson noise thermometry for temperature instrumentation

    International Nuclear Information System (INIS)

    Hwang, I. K.; Kim, Y. K.; Kim, J. S.; Moon, B. S.

    2002-01-01

    Johnson Noise Thermometry is an drift-free temperature measurement method which is able to maintain the best accuracy without calibration for a long period. Resistance Temperature Detectors (RTDs) and Thermocouples used widely in power plants have the drift problem which causes a measurement error. Despite the advantage of Johnson Noise thermometry, it has not been used because it is very sensitive to electromagnetic noise and environment. It also requires more complicated signal processing methods. This paper presents the characteristics of Johnson Noise thermometry and various implementation method proposed over the past decades time period. The key factor in development of a noise thermometer is how to extract the tiny noise signal from the sensor and discriminate out the unnecessary noise interference from the environments. The new digital technology of fast signal processing skill will useful to challenge the existing problems fir commercialization of noise thermometry

  19. Student Engagement: Developing a Conceptual Framework and Survey Instrument

    Science.gov (United States)

    Burch, Gerald F.; Heller, Nathan A.; Burch, Jana J.; Freed, Rusty; Steed, Steve A.

    2015-01-01

    Student engagement is considered to be among the better predictors of learning, yet there is growing concern that there is no consensus on the conceptual foundation. The authors propose a conceptualization of student engagement grounded in A. W. Astin's (1984) Student Involvement Theory and W. A. Kahn's (1990) employee engagement research where…

  20. INDOT Construction Inspection Priorities : Appendix B Survey Instrument

    Science.gov (United States)

    2012-05-01

    In the last decade, the Indiana Department of Transportation (INDOT) has experienced an increase in their construction projects (e.g., INDOTs construction spending was $789 million in 2006 and increased to $1,081.4 million in 2010); while the leve...

  1. BOMBAY: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Full text: Promising students had a foretaste of the latest laboratory techniques at the ICFA 1993 India School on Instrumentation in High Energy Physics held from February 15-26 and hosted by the Tata Institute of Fundamental Research (TIFR), Bombay. The scientific programme was put together by the ICFA Panel for Future Instrumentation, Innovation and Development, chaired by Tord Ekelof (Uppsala). The programme included lectures and topical seminars covering a wide range of detector subjects. In small groups, students got acquainted with modern detector technologies in the laboratory sessions, using experimental setups assembled in various institutes world-wide and shipped to Bombay for the School. The techniques covered included multiwire proportional chambers for detection of particles and photons, gaseous detectors for UV photons and X-ray imaging, the study of charge drift in silicon detectors, measurement of the muon lifetime using liquid scintillators, tracking using scintillating fibres, and electronics for sensitive detectors. The India School was attended by around 80 students from 20 countries; 34 came from Indian universities. It was the fifth in this series, previous Schools having been at Trieste (1987, 1989 and 1991) organized by the ICFA Panel and hosted and sponsored by the International Centre for Theoretical Physics, and in 1990, organized at Rio de Janeiro in collaboration with the Centro Brasileiro de Pesquisas Fisicas. The School was jointly directed by Suresh Tonwar (TIFR), Fabio Sauli (CERN) and Marleigh Sheaff (University of Wisconsin), and sponsored by TIFR and DAE (India), CERN (Switzerland), ICTP and INFN (Italy), British Council and RAL (UK), NSF and DOE (USA), KEK (Japan), IPP (Canada) and DESY (Germany)

  2. Media Lityeracy of Teachers: An Instrument for Assessing Their Competence

    Directory of Open Access Journals (Sweden)

    Vicent Gozálvez Pérez

    2014-10-01

    Full Text Available This article describes the process to elaborate and validate a survey that aims to identify and evaluate the media literacy level of non-university teachers.Currently, in a highly connected environment where media and communication technologies are increasingly relevant in the educational scope, it is essential to design an instrument that allows us to measure teachers media literacy level. This survey may support the enhancement of pedagogical proposals in order to improve teachers practice as well as teacher professional training. To validate the survey content, Delphi methodology was used by experts of seven Spanish universities. Converging validation has been done on the basis of a sample of 906 teachers from nine Spanish Autonomous Communities. The conclusion after survey psychometric analysis is that this instrument is adequate to measure media literacy level of non-university teachers.

  3. PEP surveying procedures and equipment

    International Nuclear Information System (INIS)

    Linker, F.

    1982-06-01

    The PEP Survey and Alignment System, which employs both laser-based and optical survey methods, is described. The laser is operated in conjunction with the Tektronix 4051 computer and surveying instruments such as ARM and SAM, system which is designed to automate data input, reduction, and production of alignment instructions. The laser system is used when surveying ring quadrupoles, main bend magnets, sextupoles, and is optional when surveying RF cavities and insertion quadrupoles. Optical methods usually require that data be manually entered into the computer for alignment, but in some cases, an element can be aligned using nominal values of fiducial locations without use of the computer. Optical surveying is used in the alignment of NIT and SIT, low field bend magnets, wigglers, RF cavities, and insertion quadrupoles

  4. Satisfaction measurement instruments for healthcare service users: a systematic review

    OpenAIRE

    Almeida, Renato Santos de; Bourliataux-Lajoinie, Stephane; Martins, Mônica

    2015-01-01

    Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND...

  5. Assessing the local windfield with instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, T.G.

    1980-10-01

    This report concerns the development and testing of a technique for the initial screening and evaluation of potential sites for wind-energy conversion systems (WECS). The methodology was developed through a realistic siting exercise. The siting exercise involved measurements of winds along the surface and winds aloft using a relatively new instrument system, the Tethered Aerodynamic Lifting Anemometer (TALA) kite; notation of ecological factors such as vegetation flagging, soil erosion and site exposure, and verification of an area best suited for wind-energy development by establishing and maintaining a wind monitoring network. The siting exercise was carried out in an approximately 100-square-mile region of the Tehachapi Mountains of Southern California. The results showed that a comprehensive site survey involving field measurements, ecological survey, and wind-monitoring can be an effective tool for preliminary evaluation of WECS sites.

  6. "Suntelligence" Survey

    Science.gov (United States)

    ... to the American Academy of Dermatology's "Suntelligence" sun-smart survey. Please answer the following questions to measure ... be able to view a ranking of major cities suntelligence based on residents' responses to this survey. ...

  7. Virtual Instrument Simulator for CERES

    Science.gov (United States)

    Chapman, John J.

    1997-01-01

    A benchtop virtual instrument simulator for CERES (Clouds and the Earth's Radiant Energy System) has been built at NASA, Langley Research Center in Hampton, VA. The CERES instruments will fly on several earth orbiting platforms notably NASDA's Tropical Rainfall Measurement Mission (TRMM) and NASA's Earth Observing System (EOS) satellites. CERES measures top of the atmosphere radiative fluxes using microprocessor controlled scanning radiometers. The CERES Virtual Instrument Simulator consists of electronic circuitry identical to the flight unit's twin microprocessors and telemetry interface to the supporting spacecraft electronics and two personal computers (PC) connected to the I/O ports that control azimuth and elevation gimbals. Software consists of the unmodified TRW developed Flight Code and Ground Support Software which serves as the instrument monitor and NASA/TRW developed engineering models of the scanners. The CERES Instrument Simulator will serve as a testbed for testing of custom instrument commands intended to solve in-flight anomalies of the instruments which could arise during the CERES mission. One of the supporting computers supports the telemetry display which monitors the simulator microprocessors during the development and testing of custom instrument commands. The CERES engineering development software models have been modified to provide a virtual instrument running on a second supporting computer linked in real time to the instrument flight microprocessor control ports. The CERES Instrument Simulator will be used to verify memory uploads by the CERES Flight Operations TEAM at NASA. Plots of the virtual scanner models match the actual instrument scan plots. A high speed logic analyzer has been used to track the performance of the flight microprocessor. The concept of using an identical but non-flight qualified microprocessor and electronics ensemble linked to a virtual instrument with identical system software affords a relatively inexpensive

  8. Instruments and method of air navigation

    Science.gov (United States)

    1977-01-01

    Topics discussed include magnetic and astronavigation instruments; flight beyond ground visibility; aircraft radio navigation instruments and communication radio sets; instrument landing systems; and ground controlled landing systems.

  9. Instrumentation for astronomy

    Science.gov (United States)

    Sun, Yin Sheng

    1999-12-01

    The aim of this thesis was to develop two new infrared astronomical instruments, the University of New South Wales Infrared Fabry-Perot spectrometer (UNSWIRF) and the Infrared Camera of the University of New South Wales (IRC-UNSW), and modify an optics for one existing astronomical instrument, the Automated Patrol Telescope (APT). The optical modification of the APT overcame the problem of a curved focal plane and increased the flat field of view from 0.9° to 5°, twice as big as our original goal. In addition, glass filters of 5-mm thickness can now be inserted into its f/1 beam without image blurring. The simulation, analysis and redesign of the optical system are presented in detail. Several results from testing on the sky are presented as well. UNSWIRF is a near-infrared tunable imaging spectrometer used in conjunction with IRIS on the Anglo-Australian Telescope (AAT). It is the first successful infrared Fabry-Perot spectrometer developed in Australia. Its many challenging features, such as the wide field of view, high spectral and spatial resolution and wide tunable range have been rewarded by exciting observing results obtained during commissioning in February 1996. A major contribution of this thesis has been in the calibration of the Fabry-Perot etalon. IRC-UNSW is a new near-infrared camera with a tunable Fabry-Perot for infrared astronomy. IRC-UNSW is designed for use on the 4-m Anglo-Australian Telescope (AAT) and the 2.3-m telescope of the Australian National University. The camera optics use a novel design of three off-axis mirrors, allowing correction of the off-axis aberrations in the telescopes themselves, and producing images with FWHM blur circles of 10 mm or less over a wide field of view without chromatic affects. An external Fabry- Perot etalon is used as a high-resolution spectrometer. In its opto-mechanical design, the performance of the camera with respect to thermal effects, stray light, misalignment and manufacturing errors have been

  10. Industrial instrumentation principles and design

    CERN Document Server

    Padmanabhan, Tattamangalam R

    2000-01-01

    Pneumatic, hydraulic and allied instrumentation schemes have given way to electronic schemes in recent years thanks to the rapid strides in electronics and allied areas. Principles, design and applications of such state-of-the-art instrumentation schemes form the subject matter of this book. Through representative examples, the basic building blocks of instrumentation schemes are identified and each of these building blocks discussed in terms of its design and interface characteristics. The common generic schemes synthesized with such building blocks are dealt with subsequently. This forms the scope of Part I. The focus in Part II is on application. Displacement and allied instrumentation, force and allied instrumentation and process instrumentation in terms of temperature, flow, pressure level and other common process variables are dealt with separately and exhaustively. Despite the diversity in the sensor principles and characteristics and the variety in the applications and their environments, it is possib...

  11. Impact Disdrometers Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Bartholomew, Mary Jane [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    To improve the quantitative description of precipitation processes in climate models, the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility has been collecting observations of the drop size spectra of rain events since early in 2006. Impact disdrometers were the initial choice due to their reliability, ease of maintenance, and relatively low cost. Each of the two units deployed was accompanied by a nearby tipping bucket. In 2010, the tipping buckets were replaced by weighing buckets rain gauges. Five video disdrometers were subsequently purchased and are described in ARM’s VDIS Handbook.1 As of April 2011, three of the weighing bucket instruments were deployed, one was to travel with the second ARM Mobile Facility, and the fifth was a spare. Two of the video disdrometers were deployed, a third was to be deployed later in the spring of 2011, one was to travel with the second ARM Mobile Facility, and the last was a spare. Detailed descriptions of impact disdrometers and their datastreams are provided in this document.

  12. Measurement, instrumentation, and sensors handbook

    CERN Document Server

    Eren, Halit

    2014-01-01

    The Second Edition of the bestselling Measurement, Instrumentation, and Sensors Handbook brings together all aspects of the design and implementation of measurement, instrumentation, and sensors. Reflecting the current state of the art, it describes the use of instruments and techniques for performing practical measurements in engineering, physics, chemistry, and the life sciences and discusses processing systems, automatic data acquisition, reduction and analysis, operation characteristics, accuracy, errors, calibrations, and the incorporation of standards for control purposes. Organized acco

  13. Planck 2013 results. VI. High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143,217, 353, 545...

  14. An Examination of Secondary Wind Instrument Methods Courses

    Science.gov (United States)

    Wagoner, Cynthia L.; Juchniewicz, Jay

    2017-01-01

    The purpose of this study was to investigate current secondary woodwind, brass, and combined wind instrument methods courses for preservice music teachers across the United States. Two-hundred eleven (N = 211) wind methods course instructors from National Association of Schools of Music-accredited institutions completed an online survey that…

  15. Instrument and spacecraft faults associated with nuclear radiation in space

    Science.gov (United States)

    Trainos, J. H.

    1994-01-01

    A review is given which surveys the variety of faults and failures which have occurred in space due both to the effects of single, energetic nuclear particles, as well as effects due to the accumulated ionizing dose or the fluence of nuclear particles. The review covers a variety of problems with sensors, electronics, instruments and spacecraft from several countries.

  16. Status of ART-XC/SRG Instrument

    Science.gov (United States)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; hide

    2014-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1', a field of view of approximately 34' and an expected energy resolution of about 10 percent at 14 keV.

  17. Underground research laboratory room 209 instrument array

    International Nuclear Information System (INIS)

    Lang, P.A.; Everitt, R.A.; Kozak, E.T.; Davison, C.C.

    1988-12-01

    An in situ excavation response test was conducted at the Canadian Underground Research Laboratory (URL) in conjunction with excavation of a tunnel (Room 209) through a near-vertical water-bearing fracture oriented almost perpendicular to the tunnel axis. Encountering a fracture with such desirable characteristics provided a unique opportunity during construction of the URL to try out instrumentation and analytical methods for use in the Excavation Response Experiment (ERE), one of the major URL experiments. This is the first of four reports that cover the excavation response test. This report contains the information provided to the numerical modelling groups before the start of excavation. It includes survey information of the excavations within 30 m of the instrument array; the layout of the instrument array; details of the geology, rock properties, joint characteristics, in situ stresses, and in situ rock temperature distribution; the results of hydrogeological testing and monitoring; the planned excavation sequence; and the format for the modellers to present their results to facilitate easy comparison with the measured responses. Includes 13 excavation charts in back pocket

  18. CARMENES instrument control system and operational scheduler

    Science.gov (United States)

    Garcia-Piquer, Alvaro; Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Gesa, Lluis; Morales, Juan Carlos; Pérez-Calpena, Ana; Seifert, Walter; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, José A.; Reiners, Ansgar

    2014-07-01

    The main goal of the CARMENES instrument is to perform high-accuracy measurements of stellar radial velocities (1m/s) with long-term stability. CARMENES will be installed in 2015 at the 3.5 m telescope in the Calar Alto Observatory (Spain) and it will be equipped with two spectrographs covering from the visible to the near-infrared. It will make use of its near-IR capabilities to observe late-type stars, whose peak of the spectral energy distribution falls in the relevant wavelength interval. The technology needed to develop this instrument represents a challenge at all levels. We present two software packages that play a key role in the control layer for an efficient operation of the instrument: the Instrument Control System (ICS) and the Operational Scheduler. The coordination and management of CARMENES is handled by the ICS, which is responsible for carrying out the operations of the different subsystems providing a tool to operate the instrument in an integrated manner from low to high user interaction level. The ICS interacts with the following subsystems: the near-IR and visible channels, composed by the detectors and exposure meters; the calibration units; the environment sensors; the front-end electronics; the acquisition and guiding module; the interfaces with telescope and dome; and, finally, the software subsystems for operational scheduling of tasks, data processing, and data archiving. We describe the ICS software design, which implements the CARMENES operational design and is planned to be integrated in the instrument by the end of 2014. The CARMENES operational scheduler is the second key element in the control layer described in this contribution. It is the main actor in the translation of the survey strategy into a detailed schedule for the achievement of the optimization goals. The scheduler is based on Artificial Intelligence techniques and computes the survey planning by combining the static constraints that are known a priori (i.e., target

  19. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service.

    Science.gov (United States)

    Crossno, J E; Berkins, B; Gotcher, N; Hill, J L; McConoughey, M; Walters, M

    2001-04-01

    In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas.

  20. Survey Research: Methods, Issues and the Future

    Science.gov (United States)

    Brewer, Ernest W.; Torrisi-Steele, Geraldine; Wang, Victor C. X.

    2015-01-01

    Survey research is prevalent among many professional fields. Both cost effective and time efficient, this method of research is commonly used for the purposes of gaining insight into the attitudes, thoughts, and opinions of populations. Additionally, because there are several types of survey research designs and data collection instruments, the…

  1. Youth Gangs: Experience from a Pilot Survey

    Science.gov (United States)

    Salagaev, A. L.; Shashkin, A. V.

    2005-01-01

    The present article is based on the results of an expert survey and a survey of young people in the schools of two Russian cities, Moscow and Kazan (2003). The study focused on making the research problem more explicit and testing the set of instruments, which was developed with the authors' participation in the framework of the Eurogang research…

  2. 14 CFR 27.1337 - Powerplant instruments.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant instruments. 27.1337 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Instruments: Installation § 27.1337 Powerplant instruments. (a) Instruments and instrument lines. (1) Each powerplant instrument line must meet the...

  3. 14 CFR 29.1337 - Powerplant instruments.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant instruments. 29.1337 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Instruments: Installation § 29.1337 Powerplant instruments. (a) Instruments and instrument lines. (1) Each powerplant and auxiliary power unit instrument...

  4. 14 CFR 25.1337 - Powerplant instruments.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant instruments. 25.1337 Section 25... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Instruments: Installation § 25.1337 Powerplant instruments. (a) Instruments and instrument lines. (1) Each powerplant and auxiliary power unit instrument...

  5. Experimenting with String Musical Instruments

    Science.gov (United States)

    LoPresto, Michael C.

    2012-01-01

    What follows are several investigations involving string musical instruments developed for and used in a "Science of Sound & Light" course. The experiments make use of a guitar, orchestral string instruments and data collection and graphing software. They are designed to provide students with concrete examples of how mathematical formulae, when…

  6. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  7. Developing a workplace resilience instrument.

    Science.gov (United States)

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  8. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how to mea...... was prevalent. It is uncertain whether development of a single 'all-inclusive' model for assessing integrated care is desirable. We emphasise the continuing need for validated instruments embedded in theoretical contexts.......INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how...... to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  9. Surface Meteorological Instrumentation for BOBMEX

    Indian Academy of Sciences (India)

    Although India has a long experience in ship-borne experiments and oceanographic instrumentation, the atmospheric component has not received much attention in the past. In this paper, the basis of the atmospheric instrumentation system assembled for use on board ORV Sagar Kanya for the BOBMEX- Pilot experiment ...

  10. A Database Management Assessment Instrument

    Science.gov (United States)

    Landry, Jeffrey P.; Pardue, J. Harold; Daigle, Roy; Longenecker, Herbert E., Jr.

    2013-01-01

    This paper describes an instrument designed for assessing learning outcomes in data management. In addition to assessment of student learning and ABET outcomes, we have also found the instrument to be effective for determining database placement of incoming information systems (IS) graduate students. Each of these three uses is discussed in this…

  11. Development and Validation of an Instrument for Student Evaluation of the Quality of Web-Based Instruction

    Science.gov (United States)

    Stewart, Ingrid; Hong, Eunsook; Strudler, Neal

    2004-01-01

    We developed an instrument that allows instructors to conduct a comprehensive evaluation of the quality of Web-based courses. Development and validation of the instrument involved four phases. In Phase I, an instrument was developed based on survey results from students and instructors of Web-based courses and an extensive literature review. In…

  12. Instrumentation and control system design

    International Nuclear Information System (INIS)

    Saito, Kenji; Sawahata, Hiroaki; Homma, Fumitaka; Kondo, Makoto; Mizushima, Toshihiko

    2004-01-01

    The instrumentation and control system of the high temperature engineering test reactor consists of the instrumentation, control equipments and safety protection systems. There are not many differences in the instrumentation and control equipments design between the HTTR and light water reactors except for some features. Various kinds of R and D of reactor instrumentation were performed taking into account the HTTR operational conditions, and a plant dynamic analysis was carried out considering the operational conditions of the HTTR in order to design the control system. These systems are required to have a high reliability in respect to safety. In the rise-to-power test it was confirmed that the instrumentation has a high reliability and the control system has a high stability and reasonable damped characteristics for various disturbances

  13. Smart antennas for nuclear instruments

    International Nuclear Information System (INIS)

    Jain, Ranjan Bala; Singhi, B.M.

    2005-01-01

    The advances in the field of computer and communications are leading to the development of smart embedded nuclear instruments. These instruments have highly sophisticated signal-processing algorithms based on FPGA and ASICS, provisions of present day connectivity and user interfaces. The developments in the connectivity, standards and bus technologies have made possible to access these instruments on LAN and WAN with suitable reliability and security. To get rid of wires i.e. in order to access these instruments, without wires at any place, wireless technology has evolved and become integral part of day-to-day activities. The environment monitoring can be done remotely, if smart antennas are incorporated on these instruments

  14. Survey research.

    Science.gov (United States)

    Alderman, Amy K; Salem, Barbara

    2010-10-01

    Survey research is a unique methodology that can provide insight into individuals' perspectives and experiences and can be collected on a large population-based sample. Specifically, in plastic surgery, survey research can provide patients and providers with accurate and reproducible information to assist with medical decision-making. When using survey methods in research, researchers should develop a conceptual model that explains the relationships of the independent and dependent variables. The items of the survey are of primary importance. Collected data are only useful if they accurately measure the concepts of interest. In addition, administration of the survey must follow basic principles to ensure an adequate response rate and representation of the intended target sample. In this article, the authors review some general concepts important for successful survey research and discuss the many advantages this methodology has for obtaining limitless amounts of valuable information.

  15. Instrumental variables and Mendelian randomization with invalid instruments

    Science.gov (United States)

    Kang, Hyunseung

    Instrumental variables (IV) methods have been widely used to determine the causal effect of a treatment, exposure, policy, or an intervention on an outcome of interest. The IV method relies on having a valid instrument, a variable that is (A1) associated with the exposure, (A2) has no direct effect on the outcome, and (A3) is unrelated to the unmeasured confounders associated with the exposure and the outcome. However, in practice, finding a valid instrument, especially those that satisfy (A2) and (A3), can be challenging. For example, in Mendelian randomization studies where genetic markers are used as instruments, complete knowledge about instruments' validity is equivalent to complete knowledge about the involved genes' functions. The dissertation explores the theory, methods, and application of IV methods when invalid instruments are present. First, when we have multiple candidate instruments, we establish a theoretical bound whereby causal effects are only identified as long as less than 50% of instruments are invalid, without knowing which of the instruments are invalid. We also propose a fast penalized method, called sisVIVE, to estimate the causal effect. We find that sisVIVE outperforms traditional IV methods when invalid instruments are present both in simulation studies as well as in real data analysis. Second, we propose a robust confidence interval under the multiple invalid IV setting. This work is an extension of our work on sisVIVE. However, unlike sisVIVE which is robust to violations of (A2) and (A3), our confidence interval procedure provides honest coverage even if all three assumptions, (A1)-(A3), are violated. Third, we study the single IV setting where the one IV we have may actually be invalid. We propose a nonparametric IV estimation method based on full matching, a technique popular in causal inference for observational data, that leverages observed covariates to make the instrument more valid. We propose an estimator along with

  16. Science Instrument Sensitivities to Radioisotope Power System Environment

    Science.gov (United States)

    Bairstow, Brian; Lee, Young; Smythe, William; Zakrajsek, June

    2016-01-01

    Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight

  17. Economic instruments for solid waste management in South Africa: opportunities and constraints

    CSIR Research Space (South Africa)

    Nahman, Anton

    2009-01-01

    Full Text Available This paper presents results from a survey of waste management authorities regarding the opportunities and constraints associated with the implementation of economic instruments for solid waste management in South Africa. Almost all respondents felt...

  18. Geographical positioning using laser optical instrument for near-shore underwater archaeological explorations

    Digital Repository Service at National Institute of Oceanography (India)

    Ganesan, P.

    of measuring angles and distances using laser optical instrument from the shore to obtain accurate underwater positions. The prescribed method can be applied effectively for all shallow water archaeological surveys. Under calm sea condition this method can...

  19. Torsional resistance of retreatment instruments.

    Science.gov (United States)

    Lopes, Hélio P; Elias, Carlos N; Vedovello, Gislaine A F; Bueno, Carlos E S; Mangelli, Marcelo; Siqueira, José F

    2011-10-01

    This study compared the torsional resistance of two brands of rotary nickel-titanium (NiTi) instruments indicated for endodontic retreatment. Mtwo retreatment instruments #15 and #25 (VDW, Munich, Germany) and ProTaper Universal retreatment instruments D2 and D3 (Maillefer/Dentsply, Ballaigues, Switzerland) were subjected to a torsional assay in clockwise rotation. The two parameters evaluated were maximum torque and angular deflection at failure. Fractured instruments had their fractured surfaces and helical shafts examined by scanning electron microscopy. The results indicated that the angular deflection at fracture decreased in the following order: Mtwo retreatment file #15 > Mtwo retreatment file #25 > ProTaper Universal retreatment file D2 > ProTaper Universal retreatment file D3. As for the maximum torque values, the results revealed the following descending order: ProTaper Universal file D2 > Mtwo retreatment file #25 > ProTaper Universal file D3 > Mtwo retreatment file #15. Scanning electron microscopic analysis revealed that plastic deformation occurred along the helical shaft of the fractured instruments. Fractured surfaces were of the ductile type. The instruments tested showed different torsional behavior depending on the parameter evaluated. If one considers that high angular deflection values may serve as a safety factor, then the Mtwo retreatment instruments showed significantly better results. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Instrumentation in elementary particle physics

    International Nuclear Information System (INIS)

    Fabjan, C.W.; Pilcher, J.E.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs

  1. Adjustable extender for instrument module

    International Nuclear Information System (INIS)

    Sevec, J.B.; Stein, A.D.

    1975-01-01

    A blank extender module used to mount an instrument module in front of its console for repair or test purposes has been equipped with a rotatable mount and means for locking the mount at various angles of rotation for easy accessibility. The rotatable mount includes a horizontal conduit supported by bearings within the blank module. The conduit is spring-biased in a retracted position within the blank module and in this position a small gear mounted on the conduit periphery is locked by a fixed pawl. The conduit and instrument mount can be pulled into an extended position with the gear clearing the pawl to permit rotation and adjustment of the instrument

  2. Digitalisation of optical lever instruments

    Energy Technology Data Exchange (ETDEWEB)

    Romeo, G. [Istituto Nazionale di Geofisica, Rome (Italy)

    2000-06-01

    Some classical old fashioned instruments (such as the Wood-Anderson seismometers), as well as some modern instruments (like the all-quartz made Verbaandert-Melchior tiltmeters), conventionally require an impractical recording system obtained by a photographic drum recorder in a darkroom. Simple electronic equipment (made by readily available, low cost electronics) may help in using such kind of instruments allowing a useful digital recording. This will reduce the time-hour in data acquisition and storage (and the manual error) and will increase the accuracy. The theory of operations and some results obtained using the described equipment are shown.

  3. Digitization of optical lever instruments

    Directory of Open Access Journals (Sweden)

    G. Romeo

    2000-06-01

    Full Text Available Some classical old-fashioned instruments (such as the Wood-Anderson seismometers, as well as some modern instruments (like the all-quartz made Verbaandert-Melchior tiltmeters, conventionally require an impractical recording system obtained by a photographic drum recorder in a darkroom. Simple electronic equipment (made by readily available, low cost electronics may help in using such kind of instruments allowing a useful digital recording. This will reduce the time-hour in data acquisition and storage (and the manual error, and will increase the accuracy. The theory of operations and some results obtained using the described equipment are shown.

  4. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    and surgical performance. This has prompted the attention of both practitioners and politicians some of who perceive relational coordination as a means to attain better performance. The relational coordination instrument has been validated as a measure of teamwork from the following perspectives: internal...... consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when...

  5. Commissioning Instrument for the GTC

    Science.gov (United States)

    Cuevas, S.; Sánchez, B.; Bringas, V.; Espejo, C.; Flores, R.; Chapa, O.; Lara, G.; Chavolla, A.; Anguiano, G.; Arciniega, S.; Dorantes, A.; González, J. L.; Montoya, J. M.; Toral, R.; Hernández, H.; Nava, R.; Devaney, N.; Castro, J.; Cavaller-Marqués, L.

    2005-12-01

    During the GTC integration phase, the Commissioning Instrument (CI) will be a diagnostic tool for performance verification. The CI features four operation modes: imaging, pupil imaging, Curvature WFS, and high resolution Shack-Hartmann WFS. This instrument was built by the Instituto de Astronomía UNAM and the Centro de Ingeniería y Desarrollo Industrial (CIDESI) under GRANTECAN contract after a public bid. In this paper we made a general instrument overview and we show some of the performance final results obtained when the Factory Acceptance tests previous to its transport to La Palma.

  6. Steam 80 steam generator instrumentation

    International Nuclear Information System (INIS)

    Carson, W.H.; Harris, H.H.

    1980-01-01

    This paper describes two special instrumentation packages in an integral economizer (preheater) steam generator of one of the first System 80 plants scheduled to go into commercial operation. The purpose of the instrumentation is to obtain accurate operating information from regions of the secondary side of the steam generator inaccessible to normal plant instrumentation. In addition to verification of the System 80 steam generator design predictions, the data obtained will assist in verification of steam generator thermal/hydraulic computer codes developed for generic use in the industry

  7. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  8. The Effect of Three Orchestra/School Partnerships on Students' Interest in Instrumental Music Instruction

    Science.gov (United States)

    Abeles, Hal

    2004-01-01

    This study is an examination of the influence of three orchestra/school partnerships on students' interest in instrumental music. A vocational choice school was used to assess students' interest in instrumental music. Surveys were administered to second- through fourth-grade students at partnership and nonpartnership schools. Results indicated…

  9. Digital Education Governance: Data Visualization, Predictive Analytics, and "Real-Time" Policy Instruments

    Science.gov (United States)

    Williamson, Ben

    2016-01-01

    Educational institutions and governing practices are increasingly augmented with digital database technologies that function as new kinds of policy instruments. This article surveys and maps the landscape of digital policy instrumentation in education and provides two detailed case studies of new digital data systems. The Learning Curve is a…

  10. Engineering surveying theory and examination problems for students

    CERN Document Server

    Schofield, W

    2013-01-01

    Engineering Surveying: Theory and Examination Problems for Students, Volume 1, Third Edition discusses topics concerning engineering surveying techniques and instrumentations. The book is comprised of eight chapters that cover several concerns in engineering survey. Chapter 1 discusses the basic concepts of surveying. Chapter 2 deals with simple and precise leveling, while Chapter 3 covers earthworks. The book also talks about the theodolite and its applications, and then discusses optical distance measurement. Curves, underground and hydrographic surveying, and aspects of dimensional control

  11. Intelligent instrumentation principles and applications

    CERN Document Server

    Bhuyan, Manabendra

    2011-01-01

    With the advent of microprocessors and digital-processing technologies as catalyst, classical sensors capable of simple signal conditioning operations have evolved rapidly to take on higher and more specialized functions including validation, compensation, and classification. This new category of sensor expands the scope of incorporating intelligence into instrumentation systems, yet with such rapid changes, there has developed no universal standard for design, definition, or requirement with which to unify intelligent instrumentation. Explaining the underlying design methodologies of intelligent instrumentation, Intelligent Instrumentation: Principles and Applications provides a comprehensive and authoritative resource on the scientific foundations from which to coordinate and advance the field. Employing a textbook-like language, this book translates methodologies to more than 80 numerical examples, and provides applications in 14 case studies for a complete and working understanding of the material. Beginn...

  12. Technical Training seminar: Texas Instruments

    CERN Multimedia

    2006-01-01

    Monday 6 November TECHNICAL TRAINING SEMINAR 14:00 to 17:30 - Training Centre Auditorium (bldg. 593) Texas Instruments Technical Seminar Michael Scholtholt, Field Application Engineer / TEXAS INSTRUMENTS (US, D, CH) POWER - A short approach to Texas Instruments power products Voltage mode vs. current mode control Differentiating DC/DC converters by analyzing control and compensation schemes: line / load regulation, transient response, BOM, board space, ease-of-use Introduction to the SWIFT software FPGA + CPLD power solutions WIRELESS / CHIPCON Decision criteria when choosing a RF platform Introduction to Texas Instruments wireless products: standardized platforms proprietary platforms ( 2.4 GHz / sub 1 GHz) development tools Antenna design: example for 2.4 GHz questions, discussion Industrial partners: Robert Medioni, François Caloz / Spoerle Electronic, CH-1440 Montagny (VD), Switzerland Phone: +41 24 447 0137, email: RMedioni@spoerle.com, http://www.spoerle.com Language: English. Free s...

  13. PEP instrumentation and control system

    Energy Technology Data Exchange (ETDEWEB)

    Melen, R.

    1980-06-01

    This paper describes the operating characteristics of the primary components that form the PEP Instrumentation and Control System. Descriptions are provided for the computer control system, beam monitors, and other support systems.

  14. PEP instrumentation and control system

    International Nuclear Information System (INIS)

    Melen, R.

    1980-06-01

    This paper describes the operating characteristics of the primary components that form the PEP Instrumentation and Control System. Descriptions are provided for the computer control system, beam monitors, and other support systems

  15. Compact Formaldehyde Fluorescence Instrument Element

    Data.gov (United States)

    National Aeronautics and Space Administration — The successful completion of this IRAD will deliver a fully functional instrument at TRL 6.  The key characteristics that we will demonstrate are simplicity,...

  16. Design and validation of portable optical instrument for crop diagnose

    Science.gov (United States)

    Sun, Gang; Zheng, Wengang; Huang, Wengjiang; Wan, Huawei; Liu, Liangyun

    2005-12-01

    In this paper, a portable diagnostic instrument was designed and tested, which can measure the normalized difference vegetation index (NDVI) and structure insensitive pigment index (SIPI) of crop canopy in field. The instrument have a valid survey area of 1 m*1 m when the height between instrument and the ground was fixed to 1.3 meter The crop growth condition can be assessed based on their NDVI and SIPI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. This paper also provided the method of calibration, the results showed that the average measurement error to SIPI value of instrument was 5.25% and the average measurement error to NDVI value in vegetation-covered region is 6.40%. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field.

  17. Luminescence techniques: Instrumentation and methods

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    1997-01-01

    This paper describes techniques, instruments and methods used in luminescence dating and environmental dosimetry in many laboratories around the world. These techniques are based on two phenomena - thermally stimulated luminescence and optically stimulated luminescence. The most commonly used...... luminescence stimulation and detection techniques are reviewed and information is given on recent developments in instrument design and on the stale of the art in luminescence measurements and analysis. (C) 1998 Elsevier Science Ltd. All rights reserved....

  18. Dynamic Optimization of Bytecode Instrumentation

    OpenAIRE

    Zheng Yudi; Bulej Lubomír; Zhang Cheng; Kell Stephen; Ansaloni Danilo; Binder Walter

    2013-01-01

    Accuracy completeness and performance are all major concerns in the context of dynamic program analysis. Emphasizing one of these factors may compromise the other factors. For example improving completeness of an analysis may seriously impair performance. In this paper we present an analysis model and a framework that enables reducing analysis overhead at runtime through adaptive instrumentation of the base program. Our approach targets analyses implemented with code instrumentation technique...

  19. Notes on instrumentation and control

    CERN Document Server

    Roy, G J

    2013-01-01

    Notes on Instrumentation and Control presents topics on pressure (i.e., U-tube manometers and elastic type gauges), temperature (i.e. glass thermometer, bi-metallic strip thermometer, filled system thermometer, vapor pressure thermometer), level, and flow measuring devices. The book describes other miscellaneous instruments, signal transmitting devices, supply and control systems, and monitoring systems. The theory of automatic control and semi-conductor devices are also considered. Marine engineers will find the book useful.

  20. The instrumental design of Elmer

    Science.gov (United States)

    Garcia Vargas, M.; Sánchez-Blanco, M.; Cavaller, L.; Martín-Fleitas, J.; Kohley, R.; Medina, M.; Rosich, J.; Hammersley, P. L.; Ronquillo, B.; Vega, M.

    ELMER is a visible imager spectrograph currently scheduled to be in operation at the GTC on Day One. This paper covers engineering aspects of the instrument and summarizes five poster contributions presented at this conference. ELMER is an instrument managed directly by the GTC Project Office, which has developed the preliminary design and large part of the detailed design. The detailed design, manufacturing, and testing of the structure and mechanisms is being undertaken by the join venture MEDIA-SPASA.

  1. Accounting Issues On Financial Instruments

    OpenAIRE

    Shiba, Kenji

    1995-01-01

    Financial Instruments should be measured at the present value by using the current effective yield as the discount rate by reference to the current market interest rate and the risk premium. The fair value or the current market price are surrogates of the present value. The present value determined by using the historical effective yield as the discount rate is allowed under limited circumstances. However, the historical cost is not allowed as a measurement basis of financial instruments. Thi...

  2. Instrumental development and data processing

    International Nuclear Information System (INIS)

    Franzen, J.

    1978-01-01

    A review of recent developments in mass spectrometry instrumentation is presented under the following headings: introduction (scope of mass spectrometry compared with neighbouring fields); ion sources and ionization techniques; spectrometers (instrumental developments); measuring procedures; coupling techniques; data systems; conclusions (that mass spectrometry should have a broader basis and that there would be mutual profit from a better penetration of mass spectrometry into fields of routine application). (U.K.)

  3. Sulfur Dioxide Analyzer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Springston, Stephen R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-05-01

    The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.

  4. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  5. Survey Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Cleaned and QCd data for the Fishing Effort Survey. Questions on fishing and other out are asked on weather and outdoor activity, including fishing trips. Used for...

  6. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  7. Register of Validated Short Dietary Assessment Instruments

    Science.gov (United States)

    The register contains descriptive information about the instruments identified (over 135) along with any associated validation studies and publications, and copies of the instruments themselves when available.

  8. 31 CFR 596.307 - Monetary instruments.

    Science.gov (United States)

    2010-07-01

    ... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TERRORISM LIST GOVERNMENTS SANCTIONS REGULATIONS General Definitions § 596.307 Monetary instruments. The term monetary instruments shall have the meaning...

  9. Task 5c: measurement and instrumentation under subsystem design of the LLL safeguard material control program

    International Nuclear Information System (INIS)

    1976-01-01

    A product survey was conducted of all security products currently available on the market. Documentation is presented of the survey and a printout of the data is included. A general description is given of new but recommended instrumentation and security devices for application to fuel reprocessing plants. Security systems and hardware recommended for development, assembly, and testing are discussed briefly

  10. Wide Field Instrument Adjutant Scientist

    Science.gov (United States)

    Spergel, David

    As Wide Field Instrument Adjutant Scientist, my goal will be to maximize the science capability of the mission in a cost-contained environment. I hope to work with the HQ, project and the FSWG to assure mission success. I plan to play a leadership role in communicating the WFIRST science capabilities to the astronomy community , obtain input from both science teams and the broader community that help derive performance requirements and calibration metrics. I plan to focus on developing the observing program for the deep fields and focus on using them to calibrate instrument performance and capabilities. I plan to organize workshops that will bring together WFIRST team members with astronomers working on LSST, Euclid, JWST, and the ELTs to maximize combined science return. I am also eager to explore the astrometric and stellar seismology capabilities of the instrument with a goal of maximizing science return without affecting science requirements.

  11. Technical presentation - KEITHLEY Instruments - CANCELLED

    CERN Multimedia

    FI Department

    2009-01-01

    10 March 2009 13:30 – 15:30, Council Chamber, Bldg. 503 Keithley markets highly accurate instruments and data acquisition products, as well as complete system solutions for high-volume production and assembly testing. Keithley Instruments, Inc. designs, develops, manufactures and markets complex electronic instruments and systems geared to the specialized needs of electronics manufacturers for high-performance production testing, process monitoring, product development and research. Products and Services: Digital Multimeters and Data Acquisition Systems Current / Voltage Source and Measure Products Low Current / High Resistance Measurement Products Function/Pulse/Arbitrary/Pattern Generators Low Voltage/Low Resistance Measurement Products RF Spectrum Analyzer / RF Signal Generator / RF Switching Semiconductor Device Characterization Program: Topic 1: Welcome and short overview of new Products SMU 26XXA / ARB Generator 3390 / DMM 3706 / E-Meter 6517B Topic 2a: Te...

  12. Introduction to instrumentation and measurements

    CERN Document Server

    Northrop, Robert B

    2014-01-01

    Weighing in on the growth of innovative technologies, the adoption of new standards, and the lack of educational development as it relates to current and emerging applications, the third edition of Introduction to Instrumentation and Measurements uses the authors' 40 years of teaching experience to expound on the theory, science, and art of modern instrumentation and measurements (I&M). What's New in This Edition: This edition includes material on modern integrated circuit (IC) and photonic sensors, micro-electro-mechanical (MEM) and nano-electro-mechanical (NEM) sensors, chemical and radiation sensors, signal conditioning, noise, data interfaces, and basic digital signal processing (DSP), and upgrades every chapter with the latest advancements. It contains new material on the designs of micro-electro-mechanical (MEMS) sensors, adds two new chapters on wireless instrumentation and microsensors, and incorporates extensive biomedical examples and problems. Containing 13 chapters, this third edition: Describ...

  13. Advanced Light Source instrumentation overview

    International Nuclear Information System (INIS)

    Kim, C.H.; Hinkson, J.

    1992-10-01

    The accelerator instrumentation played a vital role in commissioning the ALS injector accelerator. It helped us to see whether electron dynamics agreed with our theoretical predictions and important beam parameters met the design specifications. It helped us to see where beam losses occurred and why. In this paper we will start with a brief description of the ALS accelerator complex and the expected performance of it. Then we will describe each diagnostics instrument by its construction, operational principle, requirements, and our experiences with it. We will describe the wall current monitor, the scintillator, the Faraday cup, the beam collimator, the beam position monitor, the direct-current current transformer (DCCT), the traveling wave electrodes the Sabersky finger, and other special instruments. Finally, we will go into some detail on how we measured the beam emittances, the closed orbit, and the betatron tunes

  14. Advancements in Actuated Musical Instruments

    DEFF Research Database (Denmark)

    Overholt, Daniel; Berdahl, Edgar; Hamilton, Robert

    2011-01-01

    This article presents recent developments in actuated musical instruments created by the authors, who also describe an ecosystemic model of actuated performance activities that blur traditional boundaries between the physical and virtual elements of musical interfaces. Actuated musical instruments...... in that they produce sound via vibrating element(s) that are co-manipulated by humans and electromechanical systems. We examine the possibilities that arise when such instruments are played in different performative environments and music-making scenarios, and we postulate that such designs may give rise to new...... methods of musical performance. The Haptic Drum, the Feedback Resonance Guitar, the Electromagnetically Prepared Piano, the Overtone Fiddle and Teleoperation with Robothands are described, along with musical examples and reflections on the emergent properties of the performance ecologies...

  15. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  16. Update of Earthquake Strong-Motion Instrumentation at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Robert C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-09-01

    Following the January 1980 earthquake that was felt at Lawrence Livermore National Laboratory (LLNL), a network of strong-motion accelerographs was installed at LLNL. Prior to the 1980 earthquake, there were no accelerographs installed. The ground motion from the 1980 earthquake was estimated from USGS instruments around the Laboratory to be between 0.2 – 0.3 g horizontal peak ground acceleration. These instruments were located at the Veterans Hospital, 5 miles southwest of LLNL, and in San Ramon, about 12 miles west of LLNL. In 2011, the Department of Energy (DOE) requested to know the status of our seismic instruments. We conducted a survey of our instrumentation systems and responded to DOE in a letter. During this survey, it was found that the recorders in Buildings 111 and 332 were not operational. The instruments on Nova had been removed, and only three of the 10 NIF instruments installed in 2005 were operational (two were damaged and five had been removed from operation at the request of the program). After the survey, it was clear that the site seismic instrumentation had degraded substantially and would benefit from an overhaul and more attention to ongoing maintenance. LLNL management decided to update the LLNL seismic instrumentation system. The updated system is documented in this report.

  17. A New Automated Instrument Calibration Facility at the Savannah River Site

    International Nuclear Information System (INIS)

    Polz, E.; Rushton, R.O.; Wilkie, W.H.; Hancock, R.C.

    1998-01-01

    The Health Physics Instrument Calibration Facility at the Savannah River Site in Aiken, SC was expressly designed and built to calibrate portable radiation survey instruments. The facility incorporates recent advances in automation technology, building layout and construction, and computer software to improve the calibration process. Nine new calibration systems automate instrument calibration and data collection. The building is laid out so that instruments are moved from one area to another in a logical, efficient manner. New software and hardware integrate all functions such as shipping/receiving, work flow, calibration, testing, and report generation. Benefits include a streamlined and integrated program, improved efficiency, reduced errors, and better accuracy

  18. Advanced Technologies and Instrumentation at the National Science Foundation

    Science.gov (United States)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  19. Recent developments in nuclear instruments

    International Nuclear Information System (INIS)

    Vaidya, P.P.

    2004-01-01

    Full text : Nuclear Instrumentation is a field of vital importance for DAE. It has important applications in many areas of interest such as Reactor Monitoring and control, Accelerator based research, Laser and nuclear physics experiments, Health and environmental monitoring, Astrophysics experiments etc. It is a specialized field involving expertise in detection of radioactivity down to the level of few events per minute as well as processing and analysis of signals which can be as small as few hundred micro volts embedded in noise. Some applications involve digitizing and processing these signals with 0.001% accuracy and timing accuracies of a fraction of nano sec. Rapid developments in semiconductor related technologies have influenced the field of nuclear instrumentation. Development of FPGA's and ASIC's have made it possible to develop miniaturized smart and portable instruments for field applications. Advancements in field of computers, communications and various field buses have been successfully utilized for smart, portable and DSP based instrumentation. Smart sensor with detector and front-end electronics on a single silicon chip is now a reality. These instruments are also made intelligent by addition of fuzzy logic, artificial neural networks and expert systems. Electronics Division of BARC has made significant contribution to the field of nuclear instrumentation to achieve self-reliance in this area. This has also led to development of several new methods, which have been published in international journals and appreciated worldwide. As a step towards achieving complete self-reliance a programme for development of FPGA's, HMC's and ASIC's has been undertaken and is being followed with special emphasis. This also includes development of detector and front- end electronics on a single chip. This talk brings out details of these developments and describes the 'state of art' work done in India

  20. An introduction to biomedical instrumentation

    CERN Document Server

    Dewhurst, D J

    1976-01-01

    An Introduction to Biomedical Instrumentation presents a course of study and applications covering the basic principles of medical and biological instrumentation, as well as the typical features of its design and construction. The book aims to aid not only the cognitive domain of the readers, but also their psychomotor domain as well. Aside from the seminar topics provided, which are divided into 27 chapters, the book complements these topics with practical applications of the discussions. Figures and mathematical formulas are also given. Major topics discussed include the construction, handli

  1. Formation Flying and Deformable Instruments

    International Nuclear Information System (INIS)

    Rio, Yvon

    2009-01-01

    Astronomers have always attempted to build very stable instruments. They fight all that can cause mechanical deformation or image motion. This has led to well established technologies (autoguide, active optics, thermal control, tip/tilt correction), as well as observing methods based on the use of controlled motion (scanning, micro scanning, shift and add, chopping and nodding). Formation flying disturbs this practice. It is neither possible to reduce the relative motion to very small amplitudes, nor to control it at will. Some impacts on Simbol-X instrument design, and operation are presented.

  2. Instrumentation for tropospheric aerosol characterization

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Z.; Young, S.E.; Becker, C.H.; Coggiola, M.J. [SRI International, Menlo Park, CA (United States); Wollnik, H. [Giessen Univ. (Germany)

    1997-12-31

    A new instrument has been developed that determines the abundance, size distribution, and chemical composition of tropospheric and lower stratospheric aerosols with diameters down to 0.2 {mu}m. In addition to aerosol characterization, the instrument also monitors the chemical composition of the ambient gas. More than 25.000 aerosol particle mass spectra were recorded during the NASA-sponsored Subsonic Aircraft: Contrail and Cloud Effects Special Study (SUCCESS) field program using NASA`s DC-8 research aircraft. (author) 7 refs.

  3. Neutron-multiplication measurement instrument

    International Nuclear Information System (INIS)

    Nixon, K.V.; Dowdy, E.J.; France, S.W.; Millegan, D.R.; Robba, A.A.

    1982-01-01

    The Advanced Nuclear Technology Group of the Los Alamos National Laboratory is now using intelligent data-acquisition and analysis instrumentation for determining the multiplication of nuclear material. Earlier instrumentation, such as the large NIM-crate systems, depended on house power and required additional computation to determine multiplication or to estimate error. The portable, battery-powered multiplication measurement unit, with advanced computational power, acquires data, calculates multiplication, and completes error analysis automatically. Thus, the multiplication is determined easily and an available error estimate enables the user to judge the significance of results

  4. Instruments Sniff Organic Surface Contaminants

    Science.gov (United States)

    Adler-Golden, Steven; Matthew, Michael W.

    1995-01-01

    Portable instruments detecting both nonvolatile and volatile organic surface contaminants in real time developed. Instruments easy to use: operate under ordinary ambient atmospheric conditions, without need to use messy liquid solvents or install and remove witness plates, and without need to cut specimens from surfaces to be inspected. Principle of detection involves sweeping pure, activated gas across surface spot inspected, then monitoring light emitted at wavelengths characteristic of excited molecules formed by chemical reactions between activated gas and contaminants. Gas activated by dc discharge, radio-frequency induction, microwave radiation, laser beam, hot filaments, or any other suitable means that excites some of gas molecules.

  5. Instrumentation for Colliding Beam Physics

    CERN Document Server

    2017-01-01

    INSTR17, the International Conference on Instrumentation for Colliding Beam Physics, will be held in the Budker Institute of Nuclear Physics, Novosibirsk, Russia, on 27 February – 4 March, 2017. The conference covers novel methods of particle detection used in various experiments at particle accelerators as well as in astrophysics. It is organized in close relationship with the Vienna Conference on Instrumentation (last held in 2016) and the Pisa Meeting on Advanced Detectors (last held in 2015). The deadline for registration and abstract submission is 15 January. For more details visit the conference website instr17.inp.nsk.su. Will be published in: JINST

  6. Engineering surveying

    CERN Document Server

    Schofield, W

    2007-01-01

    Engineering surveying involves determining the position of natural and man-made features on or beneath the Earth's surface and utilizing these features in the planning, design and construction of works. It is a critical part of any engineering project. Without an accurate understanding of the size, shape and nature of the site the project risks expensive and time-consuming errors or even catastrophic failure.Engineering Surveying 6th edition covers all the basic principles and practice of this complex subject and the authors bring expertise and clarity. Previous editions of this classic text have given readers a clear understanding of fundamentals such as vertical control, distance, angles and position right through to the most modern technologies, and this fully updated edition continues that tradition.This sixth edition includes:* An introduction to geodesy to facilitate greater understanding of satellite systems* A fully updated chapter on GPS, GLONASS and GALILEO for satellite positioning in surveying* Al...

  7. SPICE: An innovative, flexible instrument concept

    Science.gov (United States)

    Nishioka, Kenji; Cauffman, D. P.; Jurcevich, B.; Mendez, David J.; Ryder, James T.

    Studies and plans for orbital capture of cosmic dust and interplanetary dust particles (IDP's) looked very bright with the advent of space station Freedom (SSF) and formal selection of Cosmic Dust Collection Facility (CDCF) as an attached payload in 1990. Unfortunately it has been downhill since its selection, culminating in CDCF being dropped as attached payload in the SSF redesign process this year. This action was without any input from the science or cosmic dust communities. The Exobiology Intact Capture Experiment (Exo-ICE) as an experiment on CDCF was also lost. Without CDCF, no facility-class instrument for cosmic dust studies is available or planned. When CDCF (and Exo-ICE) was selected as a SSF attached payload, an exercise called the small particle intact capture experiment (SPICE) was started for Exo-ICE to develop an understanding and early testing of the necessary expertise and technology for intact capture of cosmic dust and IDP's. This SPICE activity looks to fly small, meter square or less, collection area experiments on early orbital platforms of opportunity such as EURECA, MIR, WESTAR, and others, including the shuttle. The SPICE activity has focused on developing techniques and instrument concepts to capture particles intact and without inadvertent contamination. It began with a survey and screening of available capture media concepts and then focused on the development of a capture medium that can meet these requirements. Evaluation and development of the chosen capture medium, aerogel (a silicon oxide gel), has so far lived up to the expectations of meeting the requirements and is highlighted in a companion paper at this workshop. Others such as McDonnell's Timeband Capture Cell Experiment (TICCE) on EuReCa and Tsuo's GAS-CAN lid experiments on STS 47 and 57 have flown aerogel, but without addressing the contamination issue/requirement, especially regarding organics. Horz, Zolenskym and others have studied and have also been advocates for its

  8. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  9. Instrumentation

    International Nuclear Information System (INIS)

    Didierjean, B.; Jobez, J-P.; Seguinot, J.; Ypsilantis, T.

    1997-01-01

    A Hybrid Photon Detector (HPD) is currently manufactured in the framework of the tests of LHC-B collaboration. These extremely fast and sensible detectors (95% efficiency and 1 ns time accuracy for a single electron) could be utilized in many other applications: long base neutrino oscillations and possibly, HELLAZ. The model consists of an array of 2,048 1 x 1 mm 2 on Si strips of 50 mm thickness placed in glass cylinders of 127 mm diameter provided with Si windows and containing focalization electrodes. The electron circuits on 16 VA3 readout ceramic chips where designed, realized and tested. The stainless steel base card provided with 40 vacuum holes was already realised. The first production tests of visible light bi-alkali photocathodes operating in high vacuum will be performed soon. The design of the RICH2 counter (covering polar angles from 12 to 120 mrad) has been modified by turning the 120 mrad mirror to increase the spectrometer luminosity, i.e. to increase the length of the radiation path in gas by a factor of two. A second mirror sends the image in a region behind the magnetic field return, a region well-shielded from the LHC interaction zone. This design will provided 28 points for a β = 1 tracks and an angular uncertainty of 0.34 mrad per point. To cover the entire image 115 HPD will be necessary. The reconstruction of the complex systems of rings has been recently accomplished for events typical for RICH2, downstream, to discriminate between pions and kaons between 16 and 180 GeV/c. A simulation of 3,068 tracks has produced only 19 erroneous identifications, i.e. 0.6%. Another, simulation of 1,989 tracks with the RICH upstream resulted in 39 erroneous π/K identification, i.e. 2%. The report presents also the long base RICH experiment for detecting neutrino oscillations. A new version of 100 m length and 18.6 m diameter (27 kt of water) provided with HPDs of 250 mm diameter with 85 6 x 6 mm 2 arrays has been designed. Fifty such detectors will be manufactured for the in-been tests and 5,000 for the detector operated at Gran Sasso in the year 2001

  10. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  11. Literature Review of Multicultural Instrumentation

    Science.gov (United States)

    Sarraj, Huda; Carter, Stacy; Burley, Hansel

    2015-01-01

    Demographic changes at the national level emphasize a critical need for multicultural education to be included as part of undergraduate education. This critical review of the literature examines 10 multicultural instruments that are suitable for use in K-12 or higher education institutions. This is a novel literature review in that it is the first…

  12. Loyaliteitsprogramma's: zinvol CRM-instrument?

    NARCIS (Netherlands)

    Leenheer, J.

    2006-01-01

    Loyalty programs have been widely adopted by companies and their customers. A loyalty program is a relational marketing instrument that aims to enhance customer loyalty. However, skepticism exists about the implementation and effectiveness of loyalty programs. This paper studies for whom, when and

  13. Presentation of a new instrument

    DEFF Research Database (Denmark)

    Russell, M B; Rasmussen, B K; Brennum, J

    1992-01-01

    A new instrument, the Diagnostic Headache Diary, based on the operational diagnostic criteria of the International Headache Society (IHS), was tested in 61 migraine patients from a headache research clinic using the clinical diagnosis (IHS criteria) for comparison. All patients kept the diary...

  14. Maintenance of nuclear medicine instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    Maintenance of instruments is generally of two kinds: (a) corrective maintenance, on a non-scheduled basis, to restore equipment to a functional status by repairs; (b) preventive maintenance, to keep equipment in a specified functional condition by providing systematic inspection, quality control, detection and correction of early malfunctions. Most of the instruments used in nuclear medicine are rather complex systems built from mechanical, electrical and electronic parts. Any one of these components is liable to fail at some time or other. Repair could be done only by a specialist who is able to evaluate the condition of the various parts ranging from cables to connectors, from scintillators to photomultipliers, from microprocessors to microswitches. The knowledge of the intricacies of the various electronic components required for their repairs is quite wide and varied. The electronics industry turns out more and more multi-purpose chips which can carry out the functions of many parts used in the instruments of the earlier generation. This provides protection against unauthorized copying of the circuits but it serves another purpose as well of inhibiting repairs by non-factory personnel. These trends of the instrument design should be taken into consideration when a policy has to be developed for the repairs of the hospital based equipment

  15. Mobile Instruments Measure Atmospheric Pollutants

    Science.gov (United States)

    2009-01-01

    As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

  16. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  17. Meteorological instrumentation for nuclear installations

    International Nuclear Information System (INIS)

    Costa, A.C.L. da.

    1983-01-01

    The main requirements of regulatory agencies, concerning the meteorological instrumentation needed for the licensing of nuclear facilities are discussed. A description is made of the operational principles of sensors for the various meteorological parameters and associated electronic systems. Finally, it is presented an analysis of the problems associated with grounding of a typical meteorological station. (Author) [pt

  18. Meteorological instrumentation for nuclear facilities

    International Nuclear Information System (INIS)

    Costa, A.C.L. da.

    1983-01-01

    The main requirements of regulatory agencies, concerning the meteorological instrumentation needed for the licensing of nuclear facilities are discussed. A description is made of the operational principles of sensors for the various meteorological parameters and associated electronic systems. An analysis of the problems associated with grounding of a typical meteorological station is presented. (Author) [pt

  19. Market-based Economic Instruments

    DEFF Research Database (Denmark)

    Klemmensen, Børge

    2007-01-01

    Grundkategorien her er markedet som den optimale allokeringsmekanisme for de belastninger, som de økonomiske instrumenter / miljøskatterne påfører. Det mest omfattende og spektakulære eksempel på markedet som allokatorer af skatter er EU's børs for forureningstilladelser, dvs reelt CO-2 beskatnin...

  20. Scientific Instruments and Epistemology Engines

    Czech Academy of Sciences Publication Activity Database

    Dvořák, Tomáš

    2012-01-01

    Roč. 34, č. 4 (2012), s. 529-540 ISSN 1210-0250 R&D Projects: GA ČR(CZ) GAP401/11/2338 Institutional support: RVO:67985955 Keywords : material culture of science * scientific instruments * epistemology engines * experimental systems Subject RIV: AA - Philosophy ; Religion

  1. Alternative instruments for the CAP?

    NARCIS (Netherlands)

    Silvis, H.J.; Rijswick, van C.W.J.; Bont, de C.J.A.M.

    2001-01-01

    With parallel negotiations taking place on enlargement of the EU and a new WTO agreement, EU's Common Agricultural Policy is facing further reforms. This report addresses the issue of whether any alternatives can be found for the instruments of this policy, and looks at decoupled payments, a net

  2. 14 CFR 121.307 - Engine instruments.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine instruments. 121.307 Section 121.307..., FLAG, AND SUPPLEMENTAL OPERATIONS Instrument and Equipment Requirements § 121.307 Engine instruments... following engine instruments: (a) A carburetor air temperature indicator for each engine. (b) A cylinder...

  3. 40 CFR 1065.915 - PEMS instruments.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false PEMS instruments. 1065.915 Section... instruments. (a) Instrument specifications. We recommend that you use PEMS that meet the specifications of... that meets the same specifications as each lab instrument it replaces. For field testing or for testing...

  4. 14 CFR 23.1305 - Powerplant instruments.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant instruments. 23.1305 Section 23... Powerplant instruments. The following are required powerplant instruments: (a) For all airplanes. (1) A fuel... the powerplant instruments required by paragraph (a) of this section, the following powerplant...

  5. 76 FR 1063 - Modifications of Debt Instruments

    Science.gov (United States)

    2011-01-07

    ... Modifications of Debt Instruments AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Final regulation. SUMMARY: This document contains final regulations relating to the modification of debt instruments. The... into account to determine whether a modified debt instrument will be recharacterized as an instrument...

  6. Instrumentation and severe accident plant status interpretation

    International Nuclear Information System (INIS)

    Chao, J.; Machiels, A.J.; Oehlberg, R.N.; Negin, C.A.; James, R.

    1992-01-01

    EPRI is conducting a project related to instrumentation and severe accident plant status interpretation. The project will recognize the facts that (i) instrument responses during severe accidents do not need to be as accurate as during normal operation, and (ii) not all instrument loops will see a severe environment. In particular, the proposed work is to provide technology to get the most information from the existing instrumentation under severe accident conditions by developing (1) calculational aids to determine actual plant parameters based on severe-accident-affected instrument readings, and (2) means to utilize indications from operational instruments to infer parameters values for failed instruments, or where no instrument may exist. Specific deliverables for this project are (i) an instrumentation data base that will include both instrumentation failures and successes under severe conditions, and contain instrument performance information from both nuclear and non-nuclear industry situations; (ii) methods to assess the validity of instrument signals and estimate the performance of individual instrument loops; and (iii) calculational aids to estimate and interpret instrument readings under severe accident conditions, including the ability to extrapolate readings from functioning instruments to locations where instruments have failed. (orig.)

  7. Instrument Reporting Practices in Second Language Research

    Science.gov (United States)

    Derrick, Deirdre J.

    2016-01-01

    Second language (L2) researchers often have to develop or change the instruments they use to measure numerous constructs (Norris & Ortega, 2012). Given the prevalence of researcher-developed and -adapted data collection instruments, and given the profound effect instrumentation can have on results, thorough reporting of instrumentation is…

  8. Concert Band Instrumentation: Realities and Remedies.

    Science.gov (United States)

    Rogers, George L.

    1991-01-01

    Suggests ways to solve problems resulting from imbalanced instrumentation in school concert bands. Identifies sources of imbalance. Encourages band directors to plan for correct instrumentation, to match students' characteristics and abilities to instruments, and to recruit students to play needed instruments. Discusses the benefits of balanced…

  9. Instrument setpoints balancing safety and operating flexibility

    International Nuclear Information System (INIS)

    Cooley, W.H. Jr.; Leong, J.L.

    1990-01-01

    Since the early 1980's, the methods used to determine instrument setpoints have undergone significant changes, particularly in the areas of allowances for environmental effects on instrument performance. Environmental qualification programs have produced extensive information on instrument performance at off normal conditions, and regulatory authorities have shown increased interest in the details of the process by which instrument setpoints are selected. Regulatory guides have been issued and new standard developed on the subject of instrument setpoints. This increased regulatory attention has predictably led to re-evaluation of many instrument setpoints and increased conservatism in instrument settings

  10. Instrumentation requirements for the ESF thermomechanical experiments

    International Nuclear Information System (INIS)

    Pott, J.; Brechtel, C.E.

    1992-01-01

    In situ thermomechanical experiments are planned as part of the Yucca Mountain Site Characterization Project that require instruments to measure stress and displacement at temperatures that exceed the typical specifications of existing geotechnical instruments. A high degree of instrument reliability will also be required to satisfy the objectives of the experiments, therefore a study was undertaken to identify areas where improvement in instrument performance was required. A preliminary list of instruments required for the experiments was developed, based on existing test planning and analysis. Projected temperature requirements were compared to specifications of existing instruments to identify instrumentation development needs. Different instrument technologies, not currently employed in geotechnical instrumentation, were reviewed to identify potential improvements of existing designs for the high temperature environment. Technologies with strong potentials to improve instrument performance with relatively high reliability include graphite fiber composite materials, fiber optics, and video imagery

  11. Temperature documentation - instrument for quality assurance; Temperaturdokumentation - Instrument der Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Hegglin, A. [Wurm AG, Winterthur (Switzerland)

    2000-10-01

    Important inspection points of a HACCP concept are the temperatures. On the basis of the demands for a systematic temperature documentation, the application of control systems and instruments is described by several examples. (orig.) [German] Wichtige Kontrollpunkte eines HACCP-Konzepts sind die Temperaturen. Ausgehend von den Anforderungen, die an eine systematische Temperaturedokumentation gestellt werden, wird der Einsatz geeigneter Regel- und Ueberwachungsgeraete an mehreren Beispielen erlaeutert. (orig.)

  12. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service*†

    Science.gov (United States)

    Crossno, Jon E.; Berkins, Brenda; Gotcher, Nancy; Hill, Judith L.; McConoughey, Michelle; Walters, Mitchel

    2001-01-01

    Objectives: In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Methods: Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results: Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. Conclusions: ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas. PMID:11337948

  13. Development of CAMAC and Fastbus instrumentation

    International Nuclear Information System (INIS)

    Venkateswaran, Aruna; Behere, Anita; Ghodgaonkar, M.D.; Bairi, B.R.

    1987-01-01

    This report describes the work being done towards the development of CAMAC and Fast Bus Instrumentation under the VII Five Year Plan Project 'Modernisation of Reactor Control Instrumentation and Development of CAMAC and FAST BUS Instrumentation'. The report summarises the goals, objectives, principles and concepts of CAMAC and Fast Bus Instrumentation. While emphasizing the motivation behind the development of CAMAC and Fast Bus Instrumentation, the report brings out the current status and future plans of this development program. (author)

  14. ACRF Instrumentation Status and Information August 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-09-09

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  15. ACRF Instrumentation Status and Information September 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-10-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  16. ACRF Instrumentation Status and Information July 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-08-13

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  17. ACRF Instrumentation Status and Information May 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-05-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  18. ACRF Instrumentation Status and Information April 2009

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, JW

    2009-05-07

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  19. ACRF Instrumentation Status and Information - June 2009

    Energy Technology Data Exchange (ETDEWEB)

    JW Voyles

    2009-06-01

    The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following five sections: (1) new instrumentation in the process of being acquired and deployed, (2) field campaigns, (3) existing instrumentation and progress on improvements or upgrades, (4) proposed future instrumentation, and (5) Small Business Innovation Research instrument development.

  20. Fracture of rotary nickel titanium instruments

    Directory of Open Access Journals (Sweden)

    Rajendra Kumar Tewari

    2017-01-01

    Full Text Available With the advent of rotary nickel titanium (NiTi instruments, preparation of curved canals have become easy but chances of instrument separation have increased. Such an instrument separation can cause procedural problems in rendering endodontic therapy. There are various factors that cause separation of rotary NiTi instruments. These factors, various failure mechanisms and impact on the prognosis of instrument separation have to be well understood by the clinician.

  1. A summary of the performance of exposure rate and dose rate instruments contained in Instrument Evaluation Reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    A concise summary is given of the more important performance characteristics of eleven types of radiation protection dose rate and exposure rate survey instruments which have been assessed by NRPB as part of the instrument evaluation programme and published in the NRPB-IE report series. Characteristics considered are: dynamic range of exposure rate, overload performance, response as a function of photon energy, response to β radiation, response as a function of ambient temperature, battery life and the variation of indication during that life, response to pulsed sources of radiation, cost and availability of instruments. (UK)

  2. Robust Instrumentation[Water treatment for power plant]; Robust Instrumentering

    Energy Technology Data Exchange (ETDEWEB)

    Wik, Anders [Vattenfall Utveckling AB, Stockholm (Sweden)

    2003-08-01

    Cementa Slite Power Station is a heat recovery steam generator (HRSG) with moderate steam data; 3.0 MPa and 420 deg C. The heat is recovered from Cementa, a cement industry, without any usage of auxiliary fuel. The Power station commenced operation in 2001. The layout of the plant is unusual, there are no similar in Sweden and very few world-wide, so the operational experiences are limited. In connection with the commissioning of the power plant a R and D project was identified with the objective to minimise the manpower needed for chemistry management of the plant. The lean chemistry management is based on robust instrumentation and chemical-free water treatment plant. The concept with robust instrumentation consists of the following components; choice of on-line instrumentation with a minimum of O and M and a chemical-free water treatment. The parameters are specific conductivity, cation conductivity, oxygen and pH. In addition to that, two fairly new on-line instruments were included; corrosion monitors and differential pH calculated from specific and cation conductivity. The chemical-free water treatment plant consists of softening, reverse osmosis and electro-deionisation. The operational experience shows that the cycle chemistry is not within the guidelines due to major problems with the operation of the power plant. These problems have made it impossible to reach steady state and thereby not viable to fully verify and validate the concept with robust instrumentation. From readings on the panel of the online analysers some conclusions may be drawn, e.g. the differential pH measurements have fulfilled the expectations. The other on-line analysers have been working satisfactorily apart from contamination with turbine oil, which has been noticed at least twice. The corrosion monitors seem to be working but the lack of trend curves from the mainframe computer system makes it hard to draw any clear conclusions. The chemical-free water treatment has met all

  3. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  4. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added.

  5. Surveying Education

    DEFF Research Database (Denmark)

    Enemark, Stig

    2009-01-01

    . In surveying education there are a range of other challenges to be faced. These relate to the focus on learning to learn; the need for flexible curriculum to deal with constant change; the move towards introducing virtual academy; the demand for creating a quality culture; and the perspective of lifelong......In relation to surveying education there is one big question to be asked: Is the role of the surveyors changing? In a global perspective the answer will be "Yes". There is a big swing that could be entitled "From Measurement to Management". This does not imply that measurement is no longer...... learning perspective. This paper looks into the challenges in some details. It is stated that facing these challenges requires an innovative and adaptable approach to both curriculum design and course delivery within the framework of an overall quality culture. The success will eventually depend...

  6. Surveying Humaness

    DEFF Research Database (Denmark)

    Markussen, Randi; Gad, Christopher

    and personhood imagined to be already there, and communication as the free-flow of information? Is it therefore considered non-problematic that people commit themselves to remembering their past and present experience of illness and share it in detail within an - to them - unknown context? Can it even...... be imagined as a positive end, as ‘making explicit’ (in a popular psychological perspective) is considered to be therapeutic and good in itself? We will discuss those questions from a Foucaultian and ANT perspective, where one does not accept that pre-existing subjects are exposed to survey procedures....... Subjectivity is rather regulated and constituted in this practice. The relevant question becomes in what particular ways subjectivity and humanness are performed here? We want to look into this question exploring the agency of surveys, their effects and the politics involved in such a scientific practice....

  7. Readership survey

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The article reviews the last readership survey, which helped to check readers' reactions and the level and style of the journal. The majority of readers (32 per cent), not surprisingly, work in high energy physics. In fact, if the estimate of the world high energy physics population as some 5000 people is correct, CERN Courier reaches every one of them. The next large category of readers is the teaching profession (21 percent), with industrialists (12 per cent) in third place

  8. Holy Trinity of Instrumentation Development

    Science.gov (United States)

    Uršič, Rok; Šolar, Borut

    2004-11-01

    Being user friendly should be the main guidance, beside the self-understood high performance, in today's instrumentation development. Here we identify three components of the user-friendly policy: the all-in-one concept, customization, and connectivity. All-in-one is the concept of unification of various building blocks and thus various functionalities in one product. The customization is enabled by the product's reconfigurability that allows a product to grow and support new requirements and applications without changing hardware. The consequence of the two is the capacity of the single instrument to perform a variety of tasks that before were split among different devices. The last of the three is connectivity that improves the relationship between controls and beam diagnostics, brings out-of-the-crate freedom, and opens unforeseen possibilities for intra-accelerator cooperation and remote technical support.

  9. Instrumental Landing Using Audio Indication

    Science.gov (United States)

    Burlak, E. A.; Nabatchikov, A. M.; Korsun, O. N.

    2018-02-01

    The paper proposes an audio indication method for presenting to a pilot the information regarding the relative positions of an aircraft in the tasks of precision piloting. The implementation of the method is presented, the use of such parameters of audio signal as loudness, frequency and modulation are discussed. To confirm the operability of the audio indication channel the experiments using modern aircraft simulation facility were carried out. The simulated performed the instrument landing using the proposed audio method to indicate the aircraft deviations in relation to the slide path. The results proved compatible with the simulated instrumental landings using the traditional glidescope pointers. It inspires to develop the method in order to solve other precision piloting tasks.

  10. Validation of Yoon's Critical Thinking Disposition Instrument.

    Science.gov (United States)

    Shin, Hyunsook; Park, Chang Gi; Kim, Hyojin

    2015-12-01

    The lack of reliable and valid evaluation tools targeting Korean nursing students' critical thinking (CT) abilities has been reported as one of the barriers to instructing and evaluating students in undergraduate programs. Yoon's Critical Thinking Disposition (YCTD) instrument was developed for Korean nursing students, but few studies have assessed its validity. This study aimed to validate the YCTD. Specifically, the YCTD was assessed to identify its cross-sectional and longitudinal measurement invariance. This was a validation study in which a cross-sectional and longitudinal (prenursing and postnursing practicum) survey was used to validate the YCTD using 345 nursing students at three universities in Seoul, Korea. The participants' CT abilities were assessed using the YCTD before and after completing an established pediatric nursing practicum. The validity of the YCTD was estimated and then group invariance test using multigroup confirmatory factor analysis was performed to confirm the measurement compatibility of multigroups. A test of the seven-factor model showed that the YCTD demonstrated good construct validity. Multigroup confirmatory factor analysis findings for the measurement invariance suggested that this model structure demonstrated strong invariance between groups (i.e., configural, factor loading, and intercept combined) but weak invariance within a group (i.e., configural and factor loading combined). In general, traditional methods for assessing instrument validity have been less than thorough. In this study, multigroup confirmatory factor analysis using cross-sectional and longitudinal measurement data allowed validation of the YCTD. This study concluded that the YCTD can be used for evaluating Korean nursing students' CT abilities. Copyright © 2015. Published by Elsevier B.V.

  11. The Job Training and Job Satisfaction Survey Technical Manual

    Science.gov (United States)

    Schmidt, Steven W.

    2004-01-01

    Job training has become an important aspect of an employee's overall job experience. However, it is not often called out specifically on instruments measuring job satisfaction. This technical manual details the processes used in the development and validation of a survey instrument to measure job training satisfaction and overall job…

  12. Instruments de mesure en acoustique

    DEFF Research Database (Denmark)

    Tarnov, Viggo; Jacobsen, Finn

    2008-01-01

    La mesure en acoustique fait appel à des instruments qui mesurent, d'une part la pression, d'autre part l'intensité du signal. Ce dossier présentera, notamment, deux appareils spécialisés : les sonomètres et les microphones. Il abordera l'ensemble des informations majeures à connaître sur les...

  13. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  14. Virtual Instrumentation in Biomedical Equipment

    Directory of Open Access Journals (Sweden)

    Tiago Faustino Andrade

    2013-01-01

    Full Text Available Nowadays, the assessment of body composition by estimating the percentage of body fat has a great impact in many fields such as nutrition, health, sports, chronic diseases and others. The main purpose for this work is the development of a virtual instrument that permits more effective assessment of body fat, automatic data processing, recording results and storage in a database, with high potential to conduct new studies, http://lipotool.com.

  15. SMAP Instrument Mechanical System Engineering

    Science.gov (United States)

    Slimko, Eric; French, Richard; Riggs, Benjamin

    2013-01-01

    The Soil Moisture Active Passive (SMAP) mission, scheduled for launch by the end of 2014, is being developed to measure the soil moisture and soil freeze/thaw state on a global scale over a three-year period. The accuracy, resolution, and global coverage of SMAP measurements are invaluable across many science and applications disciplines including hydrology, climate, carbon cycle, and the meteorological, environment, and ecology applications communities. The SMAP observatory is composed of a despun bus and a spinning instrument platform that includes both a deployable 6 meter aperture low structural frequency Astromesh reflector and a spin control system. The instrument section has engendered challenging mechanical system issues associated with the antenna deployment, flexible antenna pointing in the context of a multitude of disturbances, spun section mass properties, spin control system development, and overall integration with the flight system on both mechanical and control system levels. Moreover, the multitude of organizations involved, including two major vendors providing the spin subsystem and reflector boom assembly plus the flight system mechanical and guidance, navigation, and control teams, has led to several unique system engineering challenges. Capturing the key physics associated with the function of the flight system has been challenging due to the many different domains that are applicable. Key interfaces and operational concepts have led to complex negotiations because of the large number of organizations that integrate with the instrument mechanical system. Additionally, the verification and validation concerns associated with the mechanical system have had required far-reaching involvement from both the flight system and other subsystems. The SMAP instrument mechanical systems engineering issues and their solutions are described in this paper.

  16. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  17. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  18. Volume 1: Instrumentation and Methods

    CERN Document Server

    Luysberg, Martina; Weirich, Thomas; EMC 2008 14th European Microscopy Congress

    2008-01-01

    Proceedings of the14th European Microscopy Congress, held in Aachen, Germany, 1-5 September 2008. Jointly organised by the European Microscopy Society (EMS), the German Society for Electron Microscopy (DGE) and the local microscopists from RWTH Aachen University and the Research Centre Jülich, the congress brings together scientists from Europe and from all over the world. The scientific programme covers all recent developments in the three major areas of instrumentation and methods, materials science and life science.

  19. Strontium Iodide Radiation Instrumentation (SIRI)

    Science.gov (United States)

    Mitchell, Lee J.; Phlips, Bernard F.; Woolf, Richard S.; Finne, Theodore T.; Johnson, W. Neil; Jackson, Emily G.

    2017-08-01

    The Strontium Iodide Radiation Instrumentation (SIRI) is designed to space-qualify new gamma-ray detector technology for space-based astrophysical and defense applications. This new technology offers improved energy resolution, lower power consumption and reduced size compared to similar systems. The SIRI instrument consists of a single europiumdoped strontium iodide (SrI2:Eu) scintillation detector. The crystal has an energy resolution of 3% at 662 keV compared to the 6.5% of traditional sodium iodide and was developed for terrestrial-based weapons of mass destruction (WMD) detection. SIRI's objective is to study the internal activation of the SrI2:Eu material and measure the performance of the silicon photomultiplier (SiPM) readouts over a 1-year mission. The combined detector and readout measure the gammaray spectrum over the energy range of 0.04 - 4 MeV. The SIRI mission payoff is a space-qualified compact, highsensitivity gamma-ray spectrometer with improved energy resolution relative to previous sensors. Scientific applications in solar physics and astrophysics include solar flares, Gamma Ray Bursts, novae, supernovae, and the synthesis of the elements. Department of Defense (DoD) and security applications are also possible. Construction of the SIRI instrument has been completed, and it is currently awaiting integration onto the spacecraft. The expected launch date is May 2018 onboard STPSat-5. This work discusses the objectives, design details and the STPSat-5 mission concept of operations of the SIRI spectrometer.

  20. TECHNICAL TRAINING SEMINAR: National Instruments

    CERN Multimedia

    Monique Duval

    2004-01-01

    From 9:30 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Data acquisition systems on PCs, industrial measurement and control techniques, advanced LabVIEW software and PXI instrumentation, and system components for tests and automation will be presented. Walk-in courses will address DIAdem, LabVIEW and data acquisition. Language: English and French Free seminars and courses, no registration Organisers: Rolf Stampfli / IT-CO / 78102 & 160367 / Rolf.Stampfli@cern.ch Davide Vitè / HR-PMD-ATT / 75141 Davide.Vite@cern.ch For more information and the complete event programme, please visit the...

  1. The instrumentation of fast reactor

    International Nuclear Information System (INIS)

    Endo, Akira

    2003-03-01

    The author has been engaged in the development of fast reactors over the last 30 years with both an involvement with the early technology development on the experimental breeder reactor Joyo, and latterly continuing this work on the prototype breeder reactor, Monju. In order to pass on this experience to younger engineers this paper is produced to outline this experience in the sincere hope that the information given will be utilised in future educational training material. The paper discusses the wide diversity on the associated instrument technology which the fast breeder reactor requires. The first chapter outlines the fast reactor system, followed by discussions on reactor instrumentation, measurement principles, temperature dependencies, and verification response characteristics from various viewpoints, are discussed in chapters two and three. The important issues of failed fuel location detection, and sodium leak detection from steam generators are discussed in chapters 4 and 5 respectively. Appended to this report is an explanation on the methods of measuring response characteristics on instrumentation systems using error analysis, random signal theory and measuring method of response characteristic by AR (autoregressive) model on which it appears is becoming an indispensable problem for persons involved with this technology in the future. (author)

  2. Measuring instruments of corporate reputation

    Directory of Open Access Journals (Sweden)

    Damir Grgić

    2008-12-01

    Full Text Available The subject of this paper is focused on the instruments for the measurement of corporate reputation. Recent research of the elements which influence the success of a company shows a growing interest in intangible values. Corporate reputation itself has been identified as one of the key intangible assets which create the company’s added value. Understanding of the importance of corporate reputation has been determined as a significant component of the company’s competitiveness, that is, of its competitive edge. Reputation is a normal part of our life and an integral part of our society. Our interest in the honesty and integrity of others is firmly established in all cultures and nowadays the focus of this interest is switching increasingly on companies. Corporate reputation can be acquired by means of strong, well-developed strategies, which are crucial for the opinion of stakeholders regarding future stability and competitive sustainability of the company. On the other hand, it should be emphasized that in order to manage it, corporate reputation has to be measured first. However, although the concept of corporate reputation is universally accepted and its significance has been recognized especially in the last two decades, the process of its measurement is still at an early stage and there is no universally accepted instrument for its measurement. Therefore, the author of this paper gives an overview of the instruments used for the measurement of corporate reputation which have gained a foothold through former practical usage.

  3. Radiations detection and nuclear instrumentation

    International Nuclear Information System (INIS)

    Abdallah, Lyoussi

    2010-01-01

    This book presents the physical principles, the performances, limits and domains of use of the main nuclear radiation detectors. The detection and characterization of a radioactive or nuclear material is possible using its characteristic, spontaneous or induced radiation emissions. Up to the end of the 1960's, the use of nuclear radiation detection and measurement methods remained limited. With the development of the nuclear industry, the main nations in concern have established control, monitoring and follow up procedures for nuclear materials and nuclear facilities as well. Nuclear detection, measurement and instrumentation started to develop and has been permanently improved and adapted thereafter. Today, nuclear instrumentation and measurement is a scientific, technical and technological subject on its own. This book presents, first, a recall of the radiation/matter interaction mechanisms with their basic physical principles. Basic and essential elements of statistics applied to radiation measurements are presented as well. Essential notions about electronic data acquisition and processing chains are explained. Then, some examples of application and use of radiation detectors are given, in particular in the domain of instrumentation and control systems for PWR type reactors. A series of exercises is proposed at the end of each chapter. (J.S.)

  4. The use of instruments of logistics and marketing in transport enterprises in lubuskie voivodeship

    Directory of Open Access Journals (Sweden)

    Agnieszka Perzyńska

    2016-09-01

    Full Text Available Background: The aim of the article is to verify the logistics and marketing instruments used in transport enterprises in Lubuskie voivodeship. The article presents the results of surveys of transport companies. Based on these studies in transport enterprises in Lubuskie, the current level of the use of logistics and marketing instruments was determined. Logistics and marketing instruments were separated to study the needs of transport companies in Lubuskie voivodeship. The choice of these instruments gave rise to a study f the possibility of using them in the implementation of business operations. From the findings it can be inferred that they are useful for the voivodeship, and that such a system can be implemented in the whole country. Methods: The study was conducted in the second half of 2014 and 140 transport enterprises in Lubuskie. Based on the research results, classifications of instruments were developed using logistics and marketing division at their levels. Results: On the basis of these findings and observations, the authors have analysed the levels of identification instruments, logistics and marketing. On this basis, it was possible to identify the instruments used by logistics and marketing in these companies. Conclusions: Based on the study of transport companies in Lubuskie voivodeship, a selection of logistics and marketing instruments were identified, along with a classification of the logistics and marketing instruments used. With the implementation of the above steps to classify the usage level of logistics and marketing instruments, the ability to match these levels to data transport companies was established.

  5. LAMOST spectral survey — An overview

    International Nuclear Information System (INIS)

    Zhao Gang; Zhao Yongheng; Chu Yaoquan; Deng Licai; Jing Yipeng

    2012-01-01

    LAMOST (Large sky Area Multi-Object fiber Spectroscopic Telescope) is a Chinese national scientific research facility operated by National Astronomical Observatories, Chinese Academy of Sciences (NAOC). After two years of commissioning beginning in 2009, the telescope, instruments, software systems and operations are nearly ready to begin the main science survey. Through a spectral survey of millions of objects in much of the northern sky, LAMOST will enable research in a number of contemporary cutting edge topics in astrophysics, such as discovery of the first generation stars in the Galaxy, pinning down the formation and evolution history of galaxies — especially the Milky Way and its central massive black hole, and looking for signatures of the distribution of dark matter and possible sub-structures in the Milky Way halo. To maximize the scientific potential of the facility, wide national participation and international collaboration have been emphasized. The survey has two major components: the LAMOST ExtraGAlactic Survey (LEGAS) and the LAMOST Experiment for Galactic Understanding and Exploration (LEGUE). Until LAMOST reaches its full capability, the LEGUE portion of the survey will use the available observing time, starting in 2012. An overview of the LAMOST project and the survey that will be carried out in the next five to six years is presented in this paper. The science plan for the whole LEGUE survey, instrumental specifications, site conditions, and the descriptions of the current on-going pilot survey, including its footprints and target selection algorithm, will be presented as separate papers in this volume.

  6. Fish species, Fish biomass, Fishery survey, invertebrate species, and other variables collected from midwater net tows, and bottom trawl observations using net, trawl, and other instruments from the Arctic Ocean, and Beaufort Sea from August 6, 2008 to August 21, 2008 (NODC Accession 0112823)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Alaska Fisheries Science Center's Status of Stocks and Multispecies Assessment (SSMA) Programs Fishery Interaction Team (FIT) conducted a fish survey in the...

  7. Assessment of instruments in facilitating investment in off-grid renewable energy projects

    International Nuclear Information System (INIS)

    Shi, Xunpeng; Liu, Xiying; Yao, Lixia

    2016-01-01

    Renewable off-grid solution plays a critical role in supporting rural electrification. However, off-grid Renewable Energy (OGRE) project financing faces significant challenges due to limited financing access, low affordability of consumers, high transactions costs and etc. Various supporting instruments have been implemented to facilitate OGRE investment. This study assesses the effectiveness of those instruments with a framework consists of three dimensions: feasibility, sustainability and replicability. The weights of each dimension in the framework and the scores of each instrument are assessed by expert surveys based on the Delphi method. It is suggested that all the three dimensions should be taken into consideration while assessing the instruments, among which feasibility and sustainability are considered as the most important dimensions in the assessment framework. Furthermore, the top-5 most effective instruments in facilitating OGRE investment are local engagement in operation and maintenance, loan guarantee, start-up grant, end user financing, and concessional finance. Developing countries that need to increase electrification, such as most of the ASEAN member states, could use these top scored instruments despite of their limited amount of public finance. - Highlights: •Assess the effectiveness of instruments for promoting financing for OGRE projects. •A three-dimension assessment framework: feasibility, sustainability, replicability. •Use online surveys and the Delphi method to collect experts’ assessment. •The most effective instruments: local engagement, loan guarantee, and start-up grant.

  8. Tool – Material, Metaphor – Metonymy, Instrument(ness)

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2008-01-01

    are controlled and conceptualized through values such as virtuosity and palyability, which are important for computer-mediated creative work supporting development in use beyond what is initially designed for. The papet performs a conceptual investigation into qualities in software interfaces that support...... creativity , supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy as central strategies for computer mediated creativity. The paper is contributing to an investigation of the aesthetics of use in relation to software...

  9. Comparison of Satellite Surveying to Traditional Surveying Methods for the Resources Industry

    Science.gov (United States)

    Osborne, B. P.; Osborne, V. J.; Kruger, M. L.

    Modern ground-based survey methods involve detailed survey, which provides three-space co-ordinates for surveyed points, to a high level of accuracy. The instruments are operated by surveyors, who process the raw results to create survey location maps for the subject of the survey. Such surveys are conducted for a location or region and referenced to the earth global co- ordinate system with global positioning system (GPS) positioning. Due to this referencing the survey is only as accurate as the GPS reference system. Satellite survey remote sensing utilise satellite imagery which have been processed using commercial geographic information system software. Three-space co-ordinate maps are generated, with an accuracy determined by the datum position accuracy and optical resolution of the satellite platform.This paper presents a case study, which compares topographic surveying undertaken by traditional survey methods with satellite surveying, for the same location. The purpose of this study is to assess the viability of satellite remote sensing for surveying in the resources industry. The case study involves a topographic survey of a dune field for a prospective mining project area in Pakistan. This site has been surveyed using modern surveying techniques and the results are compared to a satellite survey performed on the same area.Analysis of the results from traditional survey and from the satellite survey involved a comparison of the derived spatial co- ordinates from each method. In addition, comparisons have been made of costs and turnaround time for both methods.The results of this application of remote sensing is of particular interest for survey in areas with remote and extreme environments, weather extremes, political unrest, poor travel links, which are commonly associated with mining projects. Such areas frequently suffer language barriers, poor onsite technical support and resources.

  10. EEZ survey

    Science.gov (United States)

    Bell, Peter M.

    The United States Geological Survey (USGS) has contracted with the Institute of Oceanographic Sciences (IOS) to charter the research vessel Farnella. The project is to map the ocean floor at depths greater than 500 m along the recently established United States Exclusive Economic Zone (EEZ). The short range objectives include obtaining seafloor contours along the deep sea thermal spring zones in the Pacific Ocean basin. Should any of the zones prove economic for their sulfide mineral deposits, the charts should be of value to industry for years to come.

  11. Art Curriculum Influences: A National Survey

    Science.gov (United States)

    La Porte, Angela M.; Speirs, Peg; Young, Bernard

    2008-01-01

    This article is the result of an empirical study that attempts to discern the extent to which certain factors might influence current curriculum content taught by K-12 art teachers in the United States with 0 to 7 years of teaching experience. Data were collected from a sample of 437 art teachers' completion of a survey instrument with…

  12. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  13. Critical Review of Directional Neutron Survey Meters

    International Nuclear Information System (INIS)

    Balmer, M.J.I.; Gamage, K.A.A.; Taylor, G.C.

    2013-06-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. (authors)

  14. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  15. Critical review of directional neutron survey meters

    Science.gov (United States)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument.

  16. Instrumentation for core and coolant monitoring in liquid-metal fast breeder reactors (LMFBR)

    International Nuclear Information System (INIS)

    Hess, B.; Ruppert, E.

    1975-01-01

    The review on core and coolant instrumentation for liquid metal fast breeders aims to give a short survey of measurement methods and the variety of appropriate instrumentation developed and tested for reactor application throughout the world. The introductory part gives a general outline of instrumentation development, partly as the refinement of well-known thermal reactor instrumentation and partly as the special instrumentation demanded for LMFBR safety requirements, some aspects of which are also discussed briefly. The in-core LMFBR instrumentation is surveyed, classifying the measurement or monitoring of coolant properties such as temperature, pressure, flow and acoustic emission and the measurement of core-kinetic quantities such as neutron flux and reactivity. Without considering the fundamentals of the measurements, the state of instrument development is reviewed and, where known, future aspects are indicated. An additional review on fuel failure detection methods and the related instrumentation distinguishes between global or whole-core detection methods and those used for localization of failures. Special attention is paid to the aspect of reactor safety and its reliability as one of the major objectives of these detection methods. A summary of the protective systems and instrumentation already used or foreseen for LMFBR plants forms a transition to a very brief discussion of handling and interpretation of the multitude of data derived from the rather comprehensive LMFBR instrumentation. This state of the art review claims neither to be complete at the time published nor to be a detailed guide to special problems of instrumentation development, the solutions to which are normally part of industrial knowhow. (author)

  17. Proceedings of the spring meeting of the Study Group for Electronic Instrumentation on April 3-5, 1995 in Juelich

    International Nuclear Information System (INIS)

    1995-06-01

    The 17 papers presented at the meeting give a survey of recent progress in the field of electronic instrumentation of scientific and technical measuring instruments, achieved at the research centers of KFA Juelich, TU Graz, HMI Berlin, Karlsruhe FZ, and Rossendorf FZ. (DG) [de

  18. WFIRST: Data/Instrument Simulation Support at IPAC

    Science.gov (United States)

    Laine, Seppo; Akeson, Rachel; Armus, Lee; Bennett, Lee; Colbert, James; Helou, George; Kirkpatrick, J. Davy; Meshkat, Tiffany; Paladini, Roberta; Ramirez, Solange; Wang, Yun; Xie, Joan; Yan, Lin

    2018-01-01

    As part of WFIRST Science Center preparations, the IPAC Science Operations Center (ISOC) maintains a repository of 1) WFIRST data and instrument simulations, 2) tools to facilitate scientific performance and feasibility studies using the WFIRST, and 3) parameters summarizing the current design and predicted performance of the WFIRST telescope and instruments. The simulation repository provides access for the science community to simulation code, tools, and resulting analyses. Examples of simulation code with ISOC-built web-based interfaces include EXOSIMS (for estimating exoplanet yields in CGI surveys) and the Galaxy Survey Exposure Time Calculator. In the future the repository will provide an interface for users to run custom simulations of a wide range of coronagraph instrument (CGI) observations and sophisticated tools for designing microlensing experiments. We encourage those who are generating simulations or writing tools for exoplanet observations with WFIRST to contact the ISOC team so we can work with you to bring these to the attention of the broader astronomical community as we prepare for the exciting science that will be enabled by WFIRST.

  19. Compact Instruments Measure Heat Potential

    Science.gov (United States)

    2009-01-01

    Based in Huntsville, Alabama, AZ Technology Inc. is a woman- and veteran-owned business that offers expertise in electromechanical-optical design and advanced coatings. AZ Technology has received eight Small Business Innovation Research (SBIR) contracts with Marshall Space Flight Center for the development of spectral reflectometers and the measurement of surface thermal properties. The company uses a variety of measurement services and instruments, including the Spectrafire, a portable spectral emissometer it used to assist General Electric with the design of its award-winning Giraffe Warmer for neonatal intensive care units.

  20. Financial instrument pricing using C++

    CERN Document Server

    Duffy, Daniel J

    2004-01-01

    One of the best languages for the development of financial engineering and instrument pricing applications is C++. This book has several features that allow developers to write robust, flexible and extensible software systems. The book is an ANSI/ISO standard, fully object-oriented and interfaces with many third-party applications. It has support for templates and generic programming, massive reusability using templates (?write once?) and support for legacy C applications. In this book, author Daniel J. Duffy brings C++ to the next level by applying it to the design and implementation of class

  1. Starting a Small Instrument Company

    Science.gov (United States)

    Warburton, W. K.

    1997-03-01

    The author is now the owner of an 8 person company that develops specialized electronics to support the detectors used at synchrotron radiation facilities and is spinning this expertise off into developing spectrometry instruments for specialized medical markets. This talk will begin with a short history illustrating the random walk processes leading to the present situation and then consider some of the issues which a small company must deal with in order to survive. From this perspective, the author will then extract a list of steps the prospective physicist/entreprenuer can take, while still a student or post-doc, to prepare for success in growing a small business.

  2. Prevalence of temporomandibular disorders among junior high school students who play wind instruments.

    Science.gov (United States)

    Yasuda, Eriko; Honda, Kosuke; Hasegawa, Yoko; Matsumura, Eiko; Fujiwara, Masanori; Hasegawa, Makoto; Kishimoto, Hiromitsu

    2016-01-01

    This study investigated whether playing wind instruments has adverse effects on musculoskeletal functions among junior high school students who play in music clubs. The study included 210 junior high school students (35 boys, 175 girls) belonging to 1 of 4 different school clubs that practiced playing wind instruments more than 6 days/week. The mean age of the participants was 14 years. The study was performed using a questionnaire survey and an electromyographic examination of jaw and cervical muscle activities during playing wind instruments. The prevalence of temporomandibular disorders (TMD) among the children playing woodwind (WW) or brass wind (BW) instruments was higher than in those playing non-wind (NW) instruments. Long duration of playing WW with a reed mouthpiece or BW with a small mouthpiece was suggested to affect the incidence of TMD, which was more marked in girls than in boys, irrespective of height or weight. Muscle activity in the masseter muscle during playing an instrument was significantly higher in the BW with a small mouthpiece group than in the NW group (p instruments, and activity in the sternocleidomastoid muscle was significantly higher in the BW with a small mouthpiece group than in the case of other instrument groups (p instruments may have adverse effects on musculoskeletal functions among junior high school students playing in music clubs as compared with playing NW instruments. The prevalence of TMD among the students playing wind instruments was higher than in those playing other instruments. Long duration of playing those instruments affects musculoskeletal function, and this effect is more marked in girls than in boys, irrespective of height or weight. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. Prevalence of temporomandibular disorders among junior high school students who play wind instruments

    Directory of Open Access Journals (Sweden)

    Eriko Yasuda

    2016-02-01

    Full Text Available Objectives: This study investigated whether playing wind instruments has adverse effects on musculoskeletal functions among junior high school students who play in music clubs. Material and Methods: The study included 210 junior high school students (35 boys, 175 girls belonging to 1 of 4 different school clubs that practiced playing wind instruments more than 6 days/week. The mean age of the participants was 14 years. The study was performed using a questionnaire survey and an electromyographic examination of jaw and cervical muscle activities during playing wind instruments. Results: The prevalence of temporomandibular disorders (TMD among the children playing woodwind (WW or brass wind (BW instruments was higher than in those playing non-wind (NW instruments. Long duration of playing WW with a reed mouthpiece or BW with a small mouthpiece was suggested to affect the incidence of TMD, which was more marked in girls than in boys, irrespective of height or weight. Muscle activity in the masseter muscle during playing an instrument was significantly higher in the BW with a small mouthpiece group than in the NW group (p < 0.05. In cervical muscles, muscle activity of both the sternocleidomastoid and trapezius muscles was higher during playing BW than in the case of other instruments, and activity in the sternocleidomastoid muscle was significantly higher in the BW with a small mouthpiece group than in the case of other instrument groups (p < 0.05. Conclusions: Playing wind instruments may have adverse effects on musculoskeletal functions among junior high school students playing in music clubs as compared with playing NW instruments. The prevalence of TMD among the students playing wind instruments was higher than in those playing other instruments. Long duration of playing those instruments affects musculoskeletal function, and this effect is more marked in girls than in boys, irrespective of height or weight.

  4. Origins, transformations and key foci in instrumental genesis

    DEFF Research Database (Denmark)

    Tamborg, Andreas Lindenskov

    This paper investigates the origins of the instrumental genesis and instrumental orchestrations frameworks. This is done by reviewing instrumented activity situations, instrumental genesis, and instrumental orchestrations with the purpose of identifying their epistemological assumptions, what the...

  5. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  6. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lightning Instrument Package (LIP) consists of 6 rotating vane type electric field sensors along with a central computer to record and monitor the instruments....

  7. Instrumentation for three-dimensional tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.

    1981-01-01

    The Donner 280-crystal positron tomograph is described and its operation is explained. The instrument was put into operation in 1978. Possible uses of this instrument in human and animal studies are given

  8. Encapsulation process sterilizes and preserves surgical instruments

    Science.gov (United States)

    Montgomery, L. C.; Morelli, F. A.

    1964-01-01

    Ethylene oxide is blended with an organic polymer to form a sterile material for encapsulating surgical instruments. The material does not bond to metal and can be easily removed when the instruments are needed.

  9. The 2007 ESO Instrument Calibration Workshop

    CERN Document Server

    Kaufer, Andreas; ESO Workshop

    2008-01-01

    The 2007 ESO Instrument Calibration workshop brought together more than 120 participants with the objective to a) foster the sharing of information, experience and techniques between observers, instrument developers and instrument operation teams, b) review the actual precision and limitations of the applied instrument calibration plans, and c) collect the current and future requirements by the ESO users. These present proceedings include the majority of the workshop’s contributions and document the status quo of instrument calibration at ESO in large detail. Topics covered are: Optical Spectro-Imagers, Optical Multi-Object Spectrographs, NIR and MIR Spectro-Imagers, High-Resolution Spectrographs, Integral Field Spectrographs, Adaptive Optics Instruments, Polarimetric Instruments, Wide Field Imagers, Interferometric Instruments as well as other crucial aspects such as data flow, quality control, data reduction software and atmospheric effects. It was stated in the workshop that "calibration is a life-long l...

  10. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  11. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  12. Digital study of nuclear reactor instrument

    International Nuclear Information System (INIS)

    Lv Gongxiang; Yang Zhijun

    2006-01-01

    The paper introduces the design method of nuclear reactor's digital instrument developed by authors based on the AT89C52 single chip microcomputer. Also the instrument system hardware structure and software framework are given. The instrument apply DDC112 which is responsible for the measure of lower current. When designing the instrument system, anti-interference measure of software, especially hardware is considered seriously. (authors)

  13. Introduction to beam instrumentation and diagnostics

    International Nuclear Information System (INIS)

    Jones, R; Gasior, M; Lefevre, T; Schmickler, H; Wittenburg, K

    2014-01-01

    These lectures aim to describe instruments and methods used for measuring beam parameters in particle accelerators. Emphasis will be given to new detection and analysis techniques in each field of accelerator instrumentation. A clear distinction is made be tween ‘instrumentation’ , the design and construction of the instruments themselves , and ‘diagnostics’ , the use of the data from these instruments for running and improving the performance of the accelerator

  14. Instrumentness for Creativity - Mediation, Materiality & Metonymy

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2007-01-01

    We introduce the concept instrumentness as a quality of human-computer interfaces. Instrumentness points to the way musical instruments are controlled and conceptualized through values such as virtuosity and playability, which are important for computer-mediated creative work supporting development...... in use beyond what is initially designed for. The paper performs a conceptual investigation into qualities in software interfaces that support creativity, supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy...

  15. Instrumentation For Geological Fieldwork on the Moon

    OpenAIRE

    Talboys, D. L.; Fraser, G. W.; Ambrosi, R. M.; Nelms, N.; Bannister, N. P.; Sims, M. R.; Pullan, D.; Holt, J.

    2005-01-01

    A human return to the Moon will require that astronauts are well equipped with instrumentation to aid their investigations during geological field work. Two instruments are described in detail. The first is a portable X-ray Spectrometer, which can provide rapid geochemical analyses of rocks and soils, identify lunar resources and aid selection of samples for return to Earth. The second instrument is the Geological and Radiation environment package (GEORAD). This is an instrument package, moun...

  16. Economic instruments for waste management

    International Nuclear Information System (INIS)

    Malaman, R.

    1991-01-01

    Economic instruments for the implementation of environmental policies distinguish themselves from traditional tools (the 'command and control' type) for the reason that: they influence the costs and the benefits of the economic agents in question; they change the behaviour of the subjects in question in a way that they guarantee behaviour trends less harmful to the environment; they guarantee the assignment of adequate prices to the natural resources that traditionally don't have a price and therefore are consumed excessively by the economic subjects; normally they impose the transfer of economic resources to the disadvantage of the subjects responsible for the phenomena of pollution; certain objective pollution reduction data guarantee the minimization of the social costs of pollution abatement, that is, of the total costs on the economic system in general (economists define this characteristic as the 'static efficiency'); they guarantee what is called in economical jargon, the dynamic efficiency, i.e., in practice, they determine a continuous incentive for the reduction of the emission of the various pollutants and for the realization of the technological innovations that are able to control the pollution; they are more flexible than the instruments of direct regulation, because they leave the subjects a freedom of choice under different price conditions than in the past; they are flexible as well for the reason that the public operator can intervene rapidly to change the way of application

  17. Two-phase flow instrumentation

    International Nuclear Information System (INIS)

    Brand, B.; Emmerling, R.; Fischer, C.; Gaul, H.P.; Umminger, K.

    1992-01-01

    A careful measurement of the relevant two-phase flow parameters is the basis for the understanding of many thermohydraulic processes. Especially in the nuclear safety research where accident scenarios have to be simulated in experimental setups and predicted by complex computer code systems a reliable tow-phase instrumentation is substantial for the connection between analysis and experiment. Ambitious development programs have been carried out in many institutions and countries to promote two-phase instrumentation. Advantages as well as limitations of some of these systems will be discussed in the paper. In the last 10 - 15 years good progress has been made. However there are still goals for further developments and there is still the fact that in many cases - measured data taken from large experimental facilities cannot be compared directly to the parameters calculated by the codes. Careful comparison and interpretation of both calculated and measured results by experienced researchers will be the key for the thermohydraulic understanding of complex two-phase phenomena also in the future. (authors). 19 figs., 2 tabs., 18 refs

  18. Instrumentation for mass spectrometry: 1997

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.

    1997-08-01

    All mass spectrometry experiments involve the manipulation of material, an interface with the mass spectrometer, ionization, ion manipulation/analysis, detection and data collection/reduction. Each of these elements involve instrumentation. The wide range of species now amenable to mass spectrometry and the diverse areas of physical science in which it plays a role have led to a seemingly unlimited array of instrumental combinations. However, only a limited number of mass analyzers, and their combinations, dominate. The dominant analyzers include time-of-flight, Fourier transform ion cyclotron resonance, the Paul trap, the mass filter, and the sector mass spectrometer. Why there are so few (or so many, depending upon one`s point of view) can be understood upon consideration of a set of mass analyzer figures of merit. These include mass resolution, mass accuracy, mass range, dynamic range, abundance sensitivity, precision, efficiency, speed, MS{sup n} capability, compatibility with the ionizer, cost, and size. The most appropriate form of mass spectrometry is determined by the priorities of the particular measurement placed on the various mass analyzer characteristics and the relative strengths of the analyzers in meeting the requirements. Each of the analyzer types has a unique set of figures of merit that makes it optimally suited for particular applications. This paper discusses these figures of merit, provides data illustrating recent developments for each analyzer type, and gives the figures of merit of each type of analyzer as they stand in 1997. 101 refs., 24 figs.

  19. The Economic Instrument of Power and Globalization

    Science.gov (United States)

    2011-03-24

    ECONOMIC INSTRUMENT OF POWER AND GLOBALIZATION BY COLONEL JOSEPH R. FELICIANO United States...DATES COVERED (From - To) 4. TITLE AND SUBTITLE The Economic Instrument of Power and Globalization 5a. CONTRACT NUMBER 5b. GRANT...Rev. 8-98) Prescribed by ANSI Std. Z39.18 USAWC STRATEGY RESEARCH PROJECT THE ECONOMIC INSTRUMENT OF POWER AND GLOBALIZATION

  20. Instrumentation for advanced processes for coal utilization

    Energy Technology Data Exchange (ETDEWEB)

    Managan, W.W.; Raptis, A.C.; O' Fallon, N.M.; Herzenberg, C.L.

    1978-01-01

    Process control instrumentation for large-scale coal gasification, liquefaction, and fluidized-bed combustion systems is being developed at Argonne National Laboratory. Initial focus is on instrumentation to measure mass-flow rates and provide continuous in-stream analysis of solids in solids/fluids streams. These instruments and others are described.