WorldWideScience

Sample records for survey laboratory methods

  1. A survey of methods used for antimicrobial susceptibility testing in veterinary diagnostic laboratories in the United States.

    Science.gov (United States)

    Dargatz, David A; Erdman, Matthew M; Harris, Beth

    2017-09-01

    Antimicrobial resistance is a serious threat to animal and human health worldwide, requiring a collaborative, holistic approach. The U.S. Government has developed a national strategy to address antimicrobial resistance, with one component being to monitor antimicrobial resistance in agricultural settings. We developed a survey to collect information about antimicrobial susceptibility testing (AST) from the veterinary diagnostic laboratory community in the United States, assessing current practices and technologies and determining how AST information is shared. Of the 132 surveys administered, 52 (39%) were returned. Overall, responding laboratories conducted susceptibility tests on 98,788 bacterial isolates in 2014, with Escherichia coli being the most common pathogen tested across all animal species. The 2 most common AST methods employed were the disk diffusion method (71%) and the Sensititre platform broth microdilution system (59%). Laboratories primarily used the Clinical Laboratory Standards Institute (CLSI) VET-01 standard (69%) and the automatically calculated interpretations provided by the commercial AST systems (61%) for interpreting their AST data. Only 22% of laboratories published AST data on a periodic basis, usually via annual reports published on the laboratory's website or through peer-reviewed journals for specific pathogens. Our results confirm that disk diffusion and broth microdilution remain the standard AST methods employed by U.S. veterinary diagnostic laboratories, and that CLSI standards are commonly used for interpreting AST results. This information will help determine the most efficient standardized methodology for future surveillance. Furthermore, the current infrastructure within laboratories, once harmonized, will help provide a mechanism for conducting national surveillance programs.

  2. Comparability of river suspended-sediment sampling and laboratory analysis methods

    Science.gov (United States)

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  3. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  4. Development, Evaluation and Use of a Student Experience Survey in Undergraduate Science Laboratories: The Advancing Science by Enhancing Learning in the Laboratory Student Laboratory Learning Experience Survey

    Science.gov (United States)

    Barrie, Simon C.; Bucat, Robert B.; Buntine, Mark A.; Burke da Silva, Karen; Crisp, Geoffrey T.; George, Adrian V.; Jamie, Ian M.; Kable, Scott H.; Lim, Kieran F.; Pyke, Simon M.; Read, Justin R.; Sharma, Manjula D.; Yeung, Alexandra

    2015-07-01

    Student experience surveys have become increasingly popular to probe various aspects of processes and outcomes in higher education, such as measuring student perceptions of the learning environment and identifying aspects that could be improved. This paper reports on a particular survey for evaluating individual experiments that has been developed over some 15 years as part of a large national Australian study pertaining to the area of undergraduate laboratories-Advancing Science by Enhancing Learning in the Laboratory. This paper reports on the development of the survey instrument and the evaluation of the survey using student responses to experiments from different institutions in Australia, New Zealand and the USA. A total of 3153 student responses have been analysed using factor analysis. Three factors, motivation, assessment and resources, have been identified as contributing to improved student attitudes to laboratory activities. A central focus of the survey is to provide feedback to practitioners to iteratively improve experiments. Implications for practitioners and researchers are also discussed.

  5. Environmental Survey preliminary report, Argonne National Laboratory, Argonne, Illinois

    International Nuclear Information System (INIS)

    1988-11-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Argonne National Laboratory (ANL), conducted June 15 through 26, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with ANL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at ANL, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S ampersand A) Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The S ampersand A Plan will be executed by the Oak Ridge National Laboratory (ORNL). When completed, the S ampersand A results will be incorporated into the Argonne National Laboratory Environmental Survey findings for inclusion in the Environmental Survey Summary Report. 75 refs., 24 figs., 60 tabs

  6. Environmental Survey preliminary report, Argonne National Laboratory, Argonne, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    1988-11-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Argonne National Laboratory (ANL), conducted June 15 through 26, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with ANL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at ANL, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S A) Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The S A Plan will be executed by the Oak Ridge National Laboratory (ORNL). When completed, the S A results will be incorporated into the Argonne National Laboratory Environmental Survey findings for inclusion in the Environmental Survey Summary Report. 75 refs., 24 figs., 60 tabs.

  7. Geophysical surveys for buried waste detection at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Sandness, G.A.; Rising, J.L.; Kimbrough, J.R.

    1979-12-01

    This report describes a series of geophysical surveys performed at the Idaho National Engineering Laboratory (INEL). The main purpose of the surveys was to evaluate techniques, principally ground-penetrating radar, for detecting and mapping radioactive wastes buried in shallow trenches and pits. A second purpose was to determine the feasibility of using ground-penetrating radar to measure the depth of basalt bedrock. A prototype geophyscal survey system developed by the US Department of Energy's Pacific Northwest Laboratory was used for this study. Radar, magnetometer, and metal detector measurements were made at three sites in the Radioactive Waste Management Complex (RWMC) at INEL. Radar measurements were made at fourth site adjacent to the RWMC. The combination of three geophysical methods was shown to provide considerable information about the distribution of buried waste materials. The tests confirmed the potential effectiveness of the radar method, but they also pointed out the need for continued research and development in ground-penetrating radar technology. The radar system tested in this study appears to be capable of measuring the depth to basalt in the vicinity of the RWMC

  8. 2011 Annual Ecological Survey: Pacific Northwest National Laboratory Site

    Energy Technology Data Exchange (ETDEWEB)

    Becker, James M.; Chamness, Michele A.

    2012-02-27

    The U.S. Department of Energy (DOE) Pacific Northwest Site Office (PNSO) oversees and manages the DOE contract for the Pacific Northwest National Laboratory (PNNL), a DOE Office of Science multi-program laboratory located in Richland, Washington. PNSO is responsible for ensuring that all activities conducted on the PNNL site comply with applicable laws, policies, and DOE Orders. The DOE Pacific Northwest Site Office Cultural and Biological Resources Management Plan (DOE/PNSO 2008) addresses the requirement for annual surveys and monitoring for species of concern and to identify and map invasive species. In addition to the requirement for an annual survey, proposed project activities must be reviewed to assess any potential environmental consequences of conducting the project. The assessment process requires a thorough understanding of the resources present, the potential impacts of a proposed action to those resources, and the ultimate consequences of those actions. The PNNL site is situated on the southeastern corner of the DOE Hanford Site, located at the north end of the city of Richland in south-central Washington. The site is bordered on the east by the Columbia River, on the west by Stevens Drive, and on the north by the Hanford Site 300 Area (Figure 1). The environmental setting of the PNNL site is described in Larson and Downs (2009). There are currently two facilities on the PNNL site: the William R. Wiley Environmental Molecular Sciences Laboratory and the Physical Sciences Facility. This report describes the annual survey of biological resources found on the undeveloped upland portions of the PNNL site. The annual survey is comprised of a series of individual field surveys conducted on various days in late May and throughout June 2011. A brief description of the methods PNNL ecologists used to conduct the baseline surveys and a summary of the results of the surveys are presented. Appendix A provides a list of plant and animal species identified in the

  9. Summary of microsatellite instability test results from laboratories participating in proficiency surveys: proficiency survey results from 2005 to 2012.

    Science.gov (United States)

    Boyle, Theresa A; Bridge, Julia A; Sabatini, Linda M; Nowak, Jan A; Vasalos, Patricia; Jennings, Lawrence J; Halling, Kevin C

    2014-03-01

    The College of American Pathologists surveys are the largest laboratory peer comparison programs in the world. These programs allow laboratories to regularly evaluate their performance and improve the accuracy of the patient test results they provide. Proficiency testing is offered twice a year to laboratories performing microsatellite instability testing. These surveys are designed to emulate clinical practice, and some surveys have more challenging cases to encourage the refinement of laboratory practices. This report summarizes the results and trends in microsatellite instability proficiency testing from participating laboratories from the inception of the program in 2005 through 2012. We compiled and analyzed data for 16 surveys of microsatellite instability proficiency testing during 2005 to 2012. The number of laboratories participating in the microsatellite instability survey has more than doubled from 42 to 104 during the 8 years analyzed. An average of 95.4% of the laboratories correctly classified each of the survey test samples from the 2005A through 2012B proficiency challenges. In the 2011B survey, a lower percentage of laboratories (78.4%) correctly classified the specimen, possibly because of overlooking subtle changes of microsatellite instability and/or failing to enrich the tumor content of the specimen to meet the limit of detection of their assay. In general, laboratories performed well in microsatellite instability testing. This testing will continue to be important in screening patients with colorectal and other cancers for Lynch syndrome and guiding the management of patients with sporadic colorectal cancer.

  10. The Geological Survey of Canada Radiocarbon Dating Laboratory

    International Nuclear Information System (INIS)

    Lowdon, J.A.

    1985-01-01

    The Radiocarbon Dating Laboratory of the Geological Survey of Canada began routine 14 C age determinations in 1961 using a 2 litre copper, proportional counter and CO 2 as the counting gas. This counter is operated routinely at a pressure of 2 atmospheres where the maximum dating limit is approximately 40 000 years using the 4σ criterion. In 1964 a 5 litre counter was put into operation. Routinely this counter is operated at a pressure of 1 atmosphere where its dating limit is approximately 40 000 years. When operated at 4 atmospheres its age limit increases to about 54 000 years. Organic samples are burned in a stream of oxygen and the CO 2 released is purified on passage through a series of chemicals and traps. Inorganic samples are dissolved in phosphoric acid. Up to the end of 1983 more than 3700 age determinations have been carried out on various types of sample material. Since 1963 twenty-three Geological Survey of Canada Date Lists have been published. The Laboratory also carries out a program of 14 C determinations of samples of known age for the purpose of assessing the accuracy of the method and learning more about the natural and man-made 14 C distribution and circulation in nature

  11. USDOE Remote Sensing Laboratory multisensor surveys

    International Nuclear Information System (INIS)

    Tinney, L.; Christel, L.; Clark, H.; Mackey, H.

    1996-01-01

    The United States Department of Energy (USDOE) maintains a Remote Sensing Laboratory (RSL) to support nuclear related programs of the US Government. The mission of the organization includes both emergency response and routine environmental assessments of nuclear facilities. The unique suite of equipment used by RSL for multisensor surveys of nuclear facilities include gamma radiation sensors, mapping quality aerial cameras, video cameras, thermal imagers, and multispectral scanners. Results for RSL multisensor surveys that have been conducted at the Savannah River Site (SRS) located in South Carolina are presented

  12. 2010 Ecological Survey of the Pacific Northwest National Laboratory Site

    Energy Technology Data Exchange (ETDEWEB)

    Chamness, Michele A.; Perry, Christopher; Downs, Janelle L.; Powell, Sylvia D.

    2011-02-16

    The U.S. Department of Energy (DOE) Pacific Northwest Site Office (PNSO) oversees and manages the DOE contract for the Pacific Northwest National Laboratory (PNNL), a DOE Office of Science multi-program laboratory located in Richland, Washington. PNSO is responsible for ensuring that all activities conducted on the PNNL Site comply with applicable laws, policies, and DOE orders. The DOE Pacific Northwest Site Office Cultural and Biological Resources Management Plan (DOE/PNSO 2008) addresses the requirement for annual surveys and monitoring for species of concern and to identify and map invasive species. In addition to the requirement for an annual survey, proposed project activities must be reviewed to assess any potential environmental consequences of conducting the project. The assessment process requires a thorough understanding of the resources present, the potential impacts of a proposed action to those resources, and the ultimate consequences of those actions. The PNNL Site is situated on the southeastern corner of the DOE Hanford Site, located at the north end of the city of Richland in south-central Washington. The site is bordered on the east by the Columbia River, on the west by Stevens Drive, and on the north by the Hanford Site 300 Area (Figure 1). The environmental setting of the PNNL Site is described in Larson and Downs (2009). There are currently two facilities on the PNNL Site: the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL), and the recently completed Physical Sciences Facility (PSF). This report describes the results of the annual survey of the biological resources found on the undeveloped portions of the PNNL Site in 2010. A brief description of the methods PNNL ecologists used to conduct the surveys and the results of the surveys are presented. Actions taken to fully delineate noxious weed populations discovered in 2009 and efforts in 2010 to control those weeds also are described. Appendix A provides a list of plant and

  13. Efficiency in pathology laboratories: a survey of operations management in NHS bacteriology.

    Science.gov (United States)

    Szczepura, A K

    1991-01-01

    In recent years pathology laboratory services in the U.K. have experienced large increases in demand. But the extent to which U.K. laboratories have introduced controls to limit unnecessary procedures within the laboratory was previously unclear. This paper presents the results of a survey of all 343 NHS bacteriology laboratories which records the extent to which such operations management controls are now in place. The survey shows large differences between laboratories. Quality controls over inputs, the use of screening tests as a culture substitute, the use of direct susceptibility testing, controls over routine antibiotic susceptibility testing, and controls over reporting of results all vary widely. The survey also records the prevalence of hospital antibiotic policies, the extent to which laboratories produce antibiograms for user clinicians, the degree of computerisation in data handling, and the degree of automation in processing specimens. Finally, the survey uncovers a large variation between NHS labs in the percentage of bacteriology samples which prove positive and lead to antibiotic susceptibility tests being carried out.

  14. A Survey of Beginning Crop Science Courses at 49 U.S. Universities. II. Laboratory Format, Teaching Methods, and Topical Content.

    Science.gov (United States)

    Connors, Krista L.; Karnok, Keith J.

    1986-01-01

    This paper is the second of a two-part series which discusses the findings related to laboratory segments in the beginning crop science courses offered in Land Grant institutions. Survey results reveal that laboratories are used but employ traditional teaching rather than individualized or auto-tutorial techniques. (ML)

  15. State of malaria diagnostic testing at clinical laboratories in the United States, 2010: a nationwide survey

    Directory of Open Access Journals (Sweden)

    Abanyie Francisca A

    2011-11-01

    Full Text Available Abstract Background The diagnosis of malaria can be difficult in non-endemic areas, such as the United States, and delays in diagnosis and errors in treatment occur too often. Methods A nationwide survey of laboratories in the United States and its nine dependent territories was conducted in 2010 to determine factors that may contribute to shortcomings in the diagnosis of malaria. This survey explored the availability of malaria diagnostic tests, techniques used, and reporting practices. Results The survey was completed by 201 participants. Ninety percent reported that their laboratories had at least one type of malaria diagnostic test available on-site. Nearly all of the respondents' laboratories performed thick and thin smears on-site; approximately 50% had access to molecular testing; and only 17% had access to rapid diagnostic tests on-site. Seventy-three percent reported fewer than five confirmed cases of malaria in their laboratory during the 12-month period preceding the survey. Twenty-eight percent stated that results of species identification took more than 24 hours to report. Only five of 149 respondents that performed testing 24 hours a day, 7 days a week complied with all of the Clinical and Laboratory Standards Institute (CLSI guidelines for analysis and reporting of results. Conclusion Although malaria diagnostic testing services were available to a majority of U.S. laboratories surveyed, very few were in complete compliance with all of the CLSI guidelines for analysis and reporting of results, and most respondents reported very few cases of malaria annually. Laboratories' difficulty in adhering to the rigorous CLSI guidelines and their personnel's lack of practice and proficiency may account for delays and errors in diagnosis. It is recommended that laboratories that infrequently process samples for malaria seek opportunities for practice and proficiency training annually and take advantage of available resources to assist in

  16. Critical value reporting: A survey of 36 clinical laboratories in South ...

    African Journals Online (AJOL)

    A survey was carried out on 136 identified laboratories across South Africa in January 2013. Of these, 36 responded. Data collected included critical value policies, critical values for haematology parameters, and critical value reporting. Results. Of the 36 laboratories surveyed, 11.1% (n=4) were private, 33.3% (n=12) were ...

  17. Environmental survey at Lucas Heights Research Laboratories, 1993

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Looz, T.

    1995-04-01

    Results are presented of the environmental survey conducted in the neighbourhood of the Lucas Heights Research Laboratories during 1993. No activity which could have originated from these laboratories was found in samples collected from possible human food chains. All low-level liquid and gaseous waste discharges were within authorised limits. The maximum possible annual dose to the general public from airborne discharges during this period is estimated to be less than 0.01 mSv, which is one per cent of the dose limit for long term exposure that is recommended by the National Health and Medical Research Council. A list of previous environmental survey reports is attached. 22 refs., 21 tabs., 4 figs

  18. Nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia

    OpenAIRE

    Lenicek Krleza, Jasna

    2014-01-01

    Introduction: Capillary sampling is increasingly used to obtain blood for laboratory tests in volumes as small as necessary and as non-invasively as possible. Whether capillary blood sampling is also frequent in Croatia, and whether it is performed according to international laboratory standards is unclear. Materials and methods: All medical laboratories that participate in the Croatian National External Quality Assessment Program (N = 204) were surveyed on-line to collect information about t...

  19. Aerial radiological survey of the Lawrence Livermore Laboratory (Livermore, California)

    International Nuclear Information System (INIS)

    Tipton, W.J.

    1977-10-01

    An airborne radiological survey was conducted during August 1975 over several selected sites in the vicinity of Livermore, California. These sites included the Lawrence Livermore Laboratory, Sandia Livermore Laboratories, LLL Site 300, the Livermore Municipal Golf Course, and the City of Livermore's sewage treatment plant. The radiation results were processed specifically for man-made gamma ray activity. All elevated man-made activity observed during the aerial survey was contained within the site boundaries of the three DOE facilities

  20. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  1. High heterogeneity in methods used for the laboratory confirmation of pertussis diagnosis among European countries, 2010: integration of epidemiological and laboratory surveillance must include standardisation of methodologies and quality assurance.

    Science.gov (United States)

    He, Q; Barkoff, A M; Mertsola, J; Glismann, S; Bacci, S

    2012-08-09

    Despite extensive childhood immunisation, pertussis remains one of the world’s leading causes of vaccine preventable deaths. The current methods used for laboratory diagnosis of pertussis include bacterial culture, polymerase chain reaction (PCR) and enzyme linked immunosorbent assay (ELISA) serology. We conducted a questionnaire survey to identify variations in the laboratory methods and protocols used among participating countries included in the European surveillance network for vaccine-preventable diseases(EUVAC.NET). In February 2010, we performed the survey using a web-based questionnaire and sent it to the country experts of 25 European Union countries,and two European Economic Area (EEA) countries,Norway and Iceland. The questionnaire consisted of 37 questions which covered both general information on surveillance methods and detailed laboratory methods used. A descriptive analysis was performed.Questionnaires were answered by all 27 contacted countries. Nineteen countries had pertussis reference laboratories at the national level; their functions varied from performing diagnosis to providing technical advice for routine microbiology laboratories. Culture,PCR and serology were used in 17, 18 and 20 countries,respectively. For PCR, nine laboratories used insertion sequence IS481 as the target gene, which is present in multiple copies in the Bordetella pertussis genome and thus has a greater sensitivity over single copy targets, but has been proved not to be specific for B.pertussis. Antibodies directed against pertussis toxin(PT) are specific for B. pertussis infections. For ELISA serology, only 13 countries’ laboratories used purified PT as coating antigen and 10 included World Health Organization (WHO) or Food and Drug Administration (FDA) reference sera in their tests. This present survey shows that methods used for laboratory confirmation of pertussis differ widely among European countries and that there is a great heterogeneity of the reference

  2. The Horonobe Underground Research Laboratory (Tentative name) Project. A program on survey and research performed from earth surface

    International Nuclear Information System (INIS)

    2001-03-01

    The Horonobe Underground Research Laboratory (Tentative name) Project under planning at Horonobe-machi by the Japan Nuclear Cycle Development Institute (JNC) is a research facility on deep underground shown in the Long-term program on research, development and application of nuclear energy (June, 1994)' (LPNE), where some researches on the deep underground targeted at sedimentary rocks are carried out. The plan on The Horonobe Underground Research Laboratory performed at Horonobe-machi' is an about 20 years plan ranging from beginning to finishing of its survey and research, which is carried out by three steps such as 'Survey and research performed from earth surface', 'Survey and research performed under excavation of road', and Survey and research performed by using the road'. The Horonobe Underground Research Laboratory is one of research facilities on deep underground shown its importance in LPNE, and carries out some researches on the deep underground at a target of the sedimentary rocks. And also The Horonobe Underground Research Laboratory confirms some technical reliability and support on stratum disposal shown in the 'Technical reliability on stratum disposal of the high level radioactive wastes. The Second Progress Report of R and D on geological disposal' summarized on November, 1999 by JNC through actual tests and researches at the deep stratum. The obtained results are intended to reflect to disposal business of The Horonobe Underground Research Laboratory and safety regulation and so on performed by the government, together with results of stratum science research, at the Tono Geoscience Center, of geological disposal R and D at the Tokai Works, or of international collaborations. For R and D at the The Horonobe Underground Research Laboratory after 2000, following subjects are shown: 1) Survey technique on long-term stability of geological environment, 2) Survey technique on geological environment, 3) Engineering technique on engineered barrier and

  3. Critical value reporting: a survey of 36 clinical laboratories in South Africa.

    Science.gov (United States)

    Schapkaitz, Elise; Mafika, Zipho

    2013-10-11

    Critical value policies are used by clinical laboratories to decide when to notify caregivers of life-threatening results. Despite their widespread use, critical value policies have not been published locally. A survey was designed to determine critical value policies for haematology tests in South Africa. A survey was carried out on 136 identified laboratories across South Africa in January 2013. Of these, 36 responded. Data collected included critical value policies, critical values for haematology parameters, and critical value reporting. Of the 36 laboratories surveyed, 11.1% (n=4) were private, 33.3% (n=12) were affiliated to academic institutions and 55.6% (n=20) were peripheral or regional National Health Laboratory Service laboratories. All the laboratories confirmed that they had a critical value policy, and 83.3% of such policies were derived from local clinical opinion. Mean low and high critical limits for the most frequently listed tests were as follows: haemoglobin 20 g/dl, platelet count 1 000 ×10(9)/l, white cell count 46 ×10(9)/l, activated partial thromboplastin time >101 seconds, and international normalised ratio >6. In almost all cases critical value reporting was performed by the technologist on duty (97.2%). The majority of laboratories required that the person notified of the critical value be the doctor who ordered the test or the caregiver directly involved in the patient's care (83.3%); 73.3% of laboratories indicated that they followed an algorithm if the doctor/caregiver could not be reached. Each laboratory is responsible for establishing clinically relevant critical limits. Clinicians should be involved in developing the laboratory's critical value policy. The findings of this survey may be of value to local laboratories that are in the process of establishing or reviewing critical value policies.

  4. Environmental Survey preliminary report, Brookhaven National Laboratory, Upton, New York

    Energy Technology Data Exchange (ETDEWEB)

    1988-06-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Brookhaven National Laboratory (BNL) conducted April 6 through 17, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with BNL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at BNL, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing specific environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by Oak Ridge National Laboratory. When completed, the results will be incorporated into the BNL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the BNL Survey. 80 refs., 24 figs., 48 tabs.

  5. Environmental Survey preliminary report, Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    1988-06-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Brookhaven National Laboratory (BNL) conducted April 6 through 17, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with BNL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at BNL, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing specific environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by Oak Ridge National Laboratory. When completed, the results will be incorporated into the BNL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the BNL Survey. 80 refs., 24 figs., 48 tabs

  6. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    Science.gov (United States)

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  7. Environmental Survey preliminary report, Lawrence Livermore National Laboratory, Livermore, California

    Energy Technology Data Exchange (ETDEWEB)

    1987-12-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the Department of Energy (DOE) Lawrence Livermore National Laboratory (LLNL), conducted December 1 through 19, 1986. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with LLNL. The Survey covers all environmental media all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations performed at LLNL, and interviews with site personnel. A Sampling and Analysis Plan was developed to assist in further assessing certain of the environmental problems identified during performance of on-site activities. The Sampling and Analysis Plan will be executed by a DOE National Laboratory. When completed, the results will be incorporated into the LLNL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the LLNL Survey. 70 refs., 58 figs., 52 tabs.,

  8. Sandia National Laboratories, California proposed CREATE facility environmental baseline survey.

    Energy Technology Data Exchange (ETDEWEB)

    Catechis, Christopher Spyros

    2013-10-01

    Sandia National Laboratories, Environmental Programs completed an environmental baseline survey (EBS) of 12.6 acres located at Sandia National Laboratories/California (SNL/CA) in support of the proposed Collaboration in Research and Engineering for Advanced Technology and Education (CREATE) Facility. The survey area is comprised of several parcels of land within SNL/CA, County of Alameda, California. The survey area is located within T 3S, R 2E, Section 13. The purpose of this EBS is to document the nature, magnitude, and extent of any environmental contamination of the property; identify potential environmental contamination liabilities associated with the property; develop sufficient information to assess the health and safety risks; and ensure adequate protection for human health and the environment related to a specific property.

  9. Analytic Validation of Immunohistochemistry Assays: New Benchmark Data From a Survey of 1085 Laboratories.

    Science.gov (United States)

    Stuart, Lauren N; Volmar, Keith E; Nowak, Jan A; Fatheree, Lisa A; Souers, Rhona J; Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - A cooperative agreement between the College of American Pathologists (CAP) and the United States Centers for Disease Control and Prevention was undertaken to measure laboratories' awareness and implementation of an evidence-based laboratory practice guideline (LPG) on immunohistochemical (IHC) validation practices published in 2014. - To establish new benchmark data on IHC laboratory practices. - A 2015 survey on IHC assay validation practices was sent to laboratories subscribed to specific CAP proficiency testing programs and to additional nonsubscribing laboratories that perform IHC testing. Specific questions were designed to capture laboratory practices not addressed in a 2010 survey. - The analysis was based on responses from 1085 laboratories that perform IHC staining. Ninety-six percent (809 of 844) always documented validation of IHC assays. Sixty percent (648 of 1078) had separate procedures for predictive and nonpredictive markers, 42.7% (220 of 515) had procedures for laboratory-developed tests, 50% (349 of 697) had procedures for testing cytologic specimens, and 46.2% (363 of 785) had procedures for testing decalcified specimens. Minimum case numbers were specified by 85.9% (720 of 838) of laboratories for nonpredictive markers and 76% (584 of 768) for predictive markers. Median concordance requirements were 95% for both types. For initial validation, 75.4% (538 of 714) of laboratories adopted the 20-case minimum for nonpredictive markers and 45.9% (266 of 579) adopted the 40-case minimum for predictive markers as outlined in the 2014 LPG. The most common method for validation was correlation with morphology and expected results. Laboratories also reported which assay changes necessitated revalidation and their minimum case requirements. - Benchmark data on current IHC validation practices and procedures may help laboratories understand the issues and influence further refinement of LPG recommendations.

  10. Customer satisfaction survey with clinical laboratory and phlebotomy services at a tertiary care unit level.

    Science.gov (United States)

    Koh, Young Rae; Kim, Shine Young; Kim, In Suk; Chang, Chulhun L; Lee, Eun Yup; Son, Han Chul; Kim, Hyung Hoi

    2014-09-01

    We performed customer satisfaction surveys for physicians and nurses regarding clinical laboratory services, and for outpatients who used phlebotomy services at a tertiary care unit level to evaluate our clinical laboratory and phlebotomy services. Thus, we wish to share our experiences with the customer satisfaction survey for clinical laboratory and phlebotomy services. Board members of our laboratory designed a study procedure and study population, and developed two types of questionnaire. A satisfaction survey for clinical laboratory services was conducted with 370 physicians and 125 nurses by using an online or paper questionnaire. The satisfaction survey for phlebotomy services was performed with 347 outpatients who received phlebotomy services by using computer-aided interviews. Mean satisfaction scores of physicians and nurses was 58.1, while outpatients' satisfaction score was 70.5. We identified several dissatisfactions with our clinical laboratory and phlebotomy services. First, physicians and nurses were most dissatisfied with the specimen collection and delivery process. Second, physicians and nurses were dissatisfied with phlebotomy services. Third, molecular genetic and cytogenetic tests were found more expensive than other tests. This study is significant in that it describes the first reference survey that offers a survey procedure and questionnaire to assess customer satisfaction with clinical laboratory and phlebotomy services at a tertiary care unit level.

  11. The American Society for Clinical Pathology's 2015 Wage Survey of Medical Laboratories in the United States.

    Science.gov (United States)

    Garcia, Edna; Fisher, Patrick B

    2017-05-01

    To inform the pathology and laboratory field of the most recent national wage data from the American Society for Clinical Pathology (ASCP). Historically, the results of this biennial survey have served as a basis for additional research on laboratory recruitment, retention, education, marketing, certification, and advocacy. The 2015 wage survey was conducted through collaboration between the ASCP's Institute of Science, Technology, and Policy in Washington, DC, and the ASCP Board of Certification in Chicago, Illinois. Electronic survey invitations were sent to individuals who are currently practicing in the field. Data reveal increased salaries since 2013 for all staff-level laboratory professionals surveyed except phlebotomists and pathologists' assistants. Laboratory assistants and phlebotomists, regardless of level, continue to have lower salaries while pathologists' assistants and administration personnel have higher salaries than the rest of the laboratory professions surveyed. Survey results put emphasis on strategic recruitment and retention by laboratory training programs and institutions that hire laboratory professionals. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  12. Report on the International Society for Laboratory Hematology Survey on guidelines to support clinical hematology laboratory practice.

    Science.gov (United States)

    Hayward, C P M; Moffat, K A; George, T I; Proytcheva, M; Iorio, A

    2016-05-01

    Given the importance of evidence-based guidelines in health care, we surveyed the laboratory hematology community to determine their opinions on guideline development and their experience and interest in developing clinical hematology laboratory practice guidelines. The study was conducted using an online survey, distributed to members of the International Society for Laboratory Hematology (ISLH) in 2015, with analysis of collected, anonymized responses. A total of 245 individuals participated. Most worked in clinical and/or research laboratories (83%) or industry (11%). 42% felt there were gaps in current guidelines. The majority (58%) recommended that ISLH engages its membership in guideline development. Participants differed in their familiarity with, and use of, different organizations' guidelines. Participants felt it was important to follow best practice recommendations on guideline development, including engagement of experts, statement about conflict of interests and how they were managed, systematic review and grading evidence for recommendations, identifying recommendations lacking evidence or consensus, and public input and peer review of the guideline. Moreover, it was considered important to provide guidelines free of charge. Industry involvement in guidelines was considered less important. The clinical laboratory hematology community has high expectations of laboratory practice guidelines that are consistent with recent recommendations on evidence-based guideline development. © 2016 John Wiley & Sons Ltd.

  13. Environmental Survey preliminary report, Princeton Plasma Physics Laboratory, Princeton, New Jersey

    International Nuclear Information System (INIS)

    1989-05-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Princeton Plasma Physics Laboratory (PPPL), conducted June 13 through 17, 1988. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Team members are being provided by private contractors. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with PPPL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at PPPL, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S ampersand A) Plan to assist in further assessing certain of the environment problems identified during its on-site activities. The S ampersand A plan is being developed by the Idaho National Engineering Laboratory. When completed, the S ampersand A results will be incorporated into the PPPL Survey findings for inclusion in the Environmental Survey Summary Report. 70 refs., 17 figs., 21 tabs

  14. Nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia

    Science.gov (United States)

    Krleza, Jasna Lenicek

    2014-01-01

    Introduction: Capillary sampling is increasingly used to obtain blood for laboratory tests in volumes as small as necessary and as non-invasively as possible. Whether capillary blood sampling is also frequent in Croatia, and whether it is performed according to international laboratory standards is unclear. Materials and methods: All medical laboratories that participate in the Croatian National External Quality Assessment Program (N = 204) were surveyed on-line to collect information about the laboratory’s parent institution, patient population, types and frequencies of laboratory tests based on capillary blood samples, choice of reference intervals, and policies and procedures specifically related to capillary sampling. Sampling practices were compared with guidelines from the Clinical and Laboratory Standards Institute (CLSI) and the World Health Organization (WHO). Results: Of the 204 laboratories surveyed, 174 (85%) responded with complete questionnaires. Among the 174 respondents, 155 (89%) reported that they routinely perform capillary sampling, which is carried out by laboratory staff in 118 laboratories (76%). Nearly half of respondent laboratories (48%) do not have a written protocol including order of draw for multiple sampling. A single puncture site is used to provide capillary blood for up to two samples at 43% of laboratories that occasionally or regularly perform such sampling. Most respondents (88%) never perform arterialisation prior to capillary blood sampling. Conclusions: Capillary blood sampling is highly prevalent in Croatia across different types of clinical facilities and patient populations. Capillary sampling procedures are not standardised in the country, and the rate of laboratory compliance with CLSI and WHO guidelines is low. PMID:25351353

  15. Environmental survey at Lucas Heights Research Laboratories, 1989

    International Nuclear Information System (INIS)

    Hoffman, E.L.; Arthur, J.

    1990-09-01

    Results are presented of an environmental survey conducted in the neighbourhood of the Lucas Heights Research Laboratories during 1989. No radioactivity which could have originated from these laboratories was found in samples collected from possible human food chains. All low-level liquid and gaseous waste discharges were within authorised limits. The maximum possible annual dose to the general public from airborne waste during this period is estimated to be less than 0.01 millisieverts, which is one per cent of the limit for long-term exposure that is recommended by the National Health and Medical Research Council. 9 refs., 17 tabs., 2 figs

  16. Environmental survey at Lucas Heights Research Laboratories, 1990

    International Nuclear Information System (INIS)

    Hoffmann, E.L.

    1991-10-01

    Results are presented of an environmental survey conducted in the neighbourhood of the Lucas Heights Research Laboratories during 1990. No radioactivity which could have originated from these laboratories was found in samples collected from possible human food chains. All low-level liquid and gaseous waste discharges were within authorised limits. The maximum possible annual dose to the general public from airborne waste during this period is estimated to be less than 0.01 millisieverts, which is one per cent of the limit for long-term exposure that is recommended by the National Health and Medical Research Council. 11 refs., 16 tabs., 2 figs

  17. Environmental survey at Lucas Heights Research Laboratories, 1987

    International Nuclear Information System (INIS)

    Giles, M.S.; Foy, J.J.; Hoffmann, E.L.

    1989-12-01

    Results are presented of an environmental survey conducted in the neighbourhood of the Lucas Heights Research Laboratories during 1987. No radioactivity which could have originated from these laboratories was found in samples collected from possible human food chains. All low-level liquid and gaseous waste discharges were within authorized limits. The maximum possible annual dose to the general public from airborne waste during this period is estimated to be less than 0.01 millisieverts, which is one per cent of the limit for long-term exposure that is recommended by the National Health and Medical Research Council. 9 refs., 18 tabs., 2 figs

  18. Environmental survey at Lucas Heights Research Laboratories, 1984

    International Nuclear Information System (INIS)

    Giles, M.S.; Dudaitis, A.

    1986-12-01

    Results are presented of the environmental survey conducted in the neighbourhood of the Lucas Heights Research Laboratories during 1984. These results are satisfactory. No radioactivity which could have originated from these laboratories was found in samples collected from possible human food chains. All low-level liquid and gaseous waste discharges were within authorised limits. The maximum possible annual dose to the general public from airborne waste discharges during this period is estimated to be less than 0.01 millisieverts, which is one per cent of the limit for long-term exposure that is recommended by the National Health and Medical Research Council

  19. U.S. Geological Survey laboratory method for methyl tert-Butyl ether and other fuel oxygenates

    Science.gov (United States)

    Raese, Jon W.; Rose, Donna L.; Sandstrom, Mark W.

    1995-01-01

    Methyl tert-butyl ether (MTBE) was found in shallow ground-water samples in a study of 8 urban and 20 agricultural areas throughout the United States in 1993 and 1994 (Squillace and others, 1995, p. 1). The compound is added to gasoline either seasonally or year round in many parts of the United States to increase the octane level and to reduce carbon monoxide and ozone levels in the air. The U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL), near Denver, uses state-of-the-art technology to analyze samples for MTBE as part of the USGS water-quality studies. In addition, the NWQL offers custom analyses to determine two other fuel oxygenates--ethyl tert-butyl ether (ETBE) and tert-amyl methyl ether (TAME). The NWQL was not able to obtain a reference standard for tert-amyl ethyl ether (TAEE), another possible fuel oxygenate (Shelley and Fouhy, 1994, p. 63). The shallow ground-water samples were collected as part of the USGS National Water-Quality Assessment Program. These samples were collected from 211 urban wells or springs and 562 agricultural wells sampled by the USGS in 1993 and 1994. The wells were keyed to specific land-use areas to assess the effects of different uses on ground-water quality (Squillace and others, 1995, p. 2). Ground-water samples were preserved on site to pH less than or equal to 2 with a solution of 1:1 hydrochloric acid. All samples were analyzed at the NWQL within 2 weeks after collection. The purpose of this fact sheet is to explain briefly the analytical method implemented by the USGS for determining MTBE and other fuel oxygenates. The scope is necessarily limited to an overview of the analytical method (instrumentation, sample preparation, calibration and quantitation, identification, and preservation of samples) and method performance (reagent blanks, accuracy, and precision).

  20. An aerial radiological survey of the Sandia National Laboratories and surrounding area

    International Nuclear Information System (INIS)

    Riedhauser, S.R.

    1994-06-01

    A team from the Remote Sensing Laboratory conducted an aerial radiological survey of the area surrounding the Sandia National Laboratories and Kirtland Air Force Base in Albuquerque, New Mexico, during March and April 1993. The survey team measured the terrestrial gamma radiation at the site to determine the levels of natural and man-made radiation. This survey includes the areas covered by a previous survey in 1981. The results of the aerial survey show a background exposure rate which varies between 5 and 18 μR/h plus an approximate 6 μR/h contribution from cosmic rays. The major radioactive isotopes found in this survey were: potassium-40, thallium-208, bismuth-214, and actinium-228, which are all naturally-occurring isotopes, and cobalt-60, cesium-137, and excess amounts of thallium-208 and actinium-228, which are due to human actions in the survey area. In regions away from man-made activity, the exposure rates inferred from this survey's gamma ray measurements agree almost exactly with the exposure rates inferred from the 1981 survey. In addition to the aerial measurements, another survey team conducted in situ and soil sample radiation measurements at three sites within the survey perimeter. These ground-based measurements agree with the aerial measurements within ± 5%

  1. Final report on the radiological surveys of designated DX firing sites at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    1996-01-01

    CHEMRAD was contracted by Los Alamos National Laboratory to perform USRADS reg-sign (UltraSonic Ranging And Data System) radiation scanning surveys at designated DX Sites at the Los Alamos National Laboratory. The primary purpose of these scanning surveys was to identify the presence of Depleted Uranium (D-38) resulting from activities at the DX Firing Sites. This effort was conducted to update the most recent surveys of these areas. This current effort was initiated with site orientation on August 12, 1996. Surveys were completed in the field on September 4, 1996. This Executive Summary briefly presents the major findings of this work. The detail survey results are presented in the balance of this report and are organized by Technical Area and Site number in section 2. This organization is not in chronological order. USRADS and the related survey methods are described in section 3. Quality Control issues are addressed in section 4. Surveys were conducted with an array of radiation detectors either mounted on a backpack frame for man-carried use (Manual mode) or on a tricycle cart (RadCart mode). The array included radiation detectors for gamma and beta surface near surface contamination as well as dose rate at 1 meter above grade. The radiation detectors were interfaced directly to an USRADS 2100 Data Pack

  2. The American Society for Clinical Pathology's 2014 vacancy survey of medical laboratories in the United States.

    Science.gov (United States)

    Garcia, Edna; Ali, Asma M; Soles, Ryan M; Lewis, D Grace

    2015-09-01

    To determine the extent and distribution of workforce shortages within the nation's medical laboratories. Historically, the results of this biennial survey have served as a basis for additional research on laboratory recruitment, retention, education, marketing, certification, and advocacy. The 2014 Vacancy Survey was conducted through collaboration between American Society for Clinical Pathology's Institute of Science, Technology, and Policy in Washington, DC, and the Evaluation, Measurement, and Assessment Department and Board of Certification in Chicago, Illinois. Data were collected via an Internet survey that was distributed to individuals who were able to report on staffing and certifications for their laboratories. Data reveal increased overall vacancy rates since 2012 for all departments surveyed except cytology and cytogenetics. Also, results show higher anticipated retirement rates for both staff and supervisors. Overall certification rates are highest among laboratory personnel in cytogenetics, hematology/coagulation, and flow cytometry departments and lowest among phlebotomy, specimen processing, and anatomic pathology. Factors such as retirement and the improving economy are driving the need for more laboratory professionals. Recruitment of qualified laboratory professionals in the workforce and students in laboratory programs will be the key in fulfilling the higher vacancies revealed from the survey results in 2014. Copyright© by the American Society for Clinical Pathology.

  3. The Laboratory Course Assessment Survey: A Tool to Measure Three Dimensions of Research-Course Design

    Science.gov (United States)

    Corwin, Lisa A.; Runyon, Christopher; Robinson, Aspen; Dolan, Erin L.

    2015-01-01

    Course-based undergraduate research experiences (CUREs) are increasingly being offered as scalable ways to involve undergraduates in research. Yet few if any design features that make CUREs effective have been identified. We developed a 17-item survey instrument, the Laboratory Course Assessment Survey (LCAS), that measures students’ perceptions of three design features of biology lab courses: 1) collaboration, 2) discovery and relevance, and 3) iteration. We assessed the psychometric properties of the LCAS using established methods for instrument design and validation. We also assessed the ability of the LCAS to differentiate between CUREs and traditional laboratory courses, and found that the discovery and relevance and iteration scales differentiated between these groups. Our results indicate that the LCAS is suited for characterizing and comparing undergraduate biology lab courses and should be useful for determining the relative importance of the three design features for achieving student outcomes. PMID:26466990

  4. Perceptions of a medical microbiology service: a survey of laboratory users.

    Science.gov (United States)

    Morgan, M S

    1995-01-01

    AIM--To ascertain the perception of laboratory users regarding the quality of the medical microbiology services in a district general hospital. METHODS--Detailed questionnaires were circulated to all clinicians in the locality, with headings covering the quality of medical advice provided, the availability of information on specimen collection, format of request forms, specimen transport arrangements, turnaround times, the quality and need for interpretative advice, and the overall impression of the quality of the services provided. RESULTS--Two hundred and thirty five replies were received, giving a response rate of 69%. Transportation of specimens and communication of reports were identified as priority areas for improvement. The overall quality of the service was perceived as satisfactory, although areas were identified where substantial improvements could be made, some at little or no cost to the laboratory. CONCLUSIONS--The survey focused clinicians' attention on the service, raised the profile of the laboratory, and resulted in improved communications and a better understanding of customer needs. Overall, the exercise was felt to be extremely useful, and worthwhile repeating to gauge the effect of the changes instituted as a result. PMID:8537489

  5. Results of the radiological survey at the former Alba Craft Laboratory site properties, Oxford, Ohio (OXO001)

    International Nuclear Information System (INIS)

    Murray, M.E.; Brown, K.S.; Mathis, R.A.

    1993-03-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at the former Alba Craft Laboratory Site Properties, Oxford, Ohio. The survey was performed in July and September of 1992. The purpose of the survey was to determine whether the property was contaminated with radioactive residues, primarily 238 U, from uranium machining operations conducted for National Lead of Ohio, a prime Atomic Energy Commission contractor. The survey included scan measurement of direct radiation levels inside and outside the former laboratory, outdoors on eight properties adjoining the former laboratory, and the city right-of-way adjacent to the surveyed properties. Radionuclide concentrations were determined in outdoor surface and subsurface soil samples taken from each property and the exterior of the laboratory. Fixed surface residual radioactivity was measured inside the laboratory and outside the building. Air samples were collected, direct exposure was measured, and samples were collected to measure transferable radioactivity inside the building. Results of the survey indicate areas where surface and soil contamination level s are above the DOE guidelines for uncontrolled areas

  6. Survey and analysis of materials research and development at selected federal laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Reed, J.E.; Fink, C.R.

    1984-04-01

    This document presents the results of an effort to transfer existing, but relatively unknown, materials R and D from selected federal laboratories to industry. More specifically, recent materials-related work at seven federal laboratories potentially applicable to improving process energy efficiency and overall productiviy in six energy-intensive manufacturing industries was evaluated, catalogued, and distributed to industry representatives to gauge their reaction. Laboratories surveyed include: Air Force Wright Aeronautical Laboratories Material Laboratory (AFWAL). Pacific Northwest Laboratory (PNL), National Aeronautics and Space Administration Marshall Flight Center (NASA Marshall), Oak Ridge National Laboratory (ORNL), Brookhaven National Laboratory (BNL), Idaho National Engineering Laboratory (INEL), and Jet Propulsion Laboratory (JPL). Industries included in the effort are: aluminum, cement, paper and allied products, petroleum, steel and textiles.

  7. Environmental Survey preliminary report, Fermi National Accelerator Laboratory, Batavia, Illinois

    International Nuclear Information System (INIS)

    1988-10-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the US Department of Energy (DOE) Fermi National Accelerator Laboratory (Fermilab), conducted September 14 through 25, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual participants for the Survey team are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with Fermilab. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations performed at Fermilab, and interviews with site personnel. 110 refs., 26 figs., 41 tabs

  8. Environmental Survey preliminary report, Fermi National Accelerator Laboratory, Batavia, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    1988-10-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the US Department of Energy (DOE) Fermi National Accelerator Laboratory (Fermilab), conducted September 14 through 25, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual participants for the Survey team are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with Fermilab. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations performed at Fermilab, and interviews with site personnel. 110 refs., 26 figs., 41 tabs.

  9. The laboratory of quantitative methods in historic monument research at the CTU Prague

    International Nuclear Information System (INIS)

    Musilek, L.; Cechak, T.; Kubelik, M.; Pavelka, K.; Pavlik, M.

    2001-01-01

    A 'Laboratory of Quantitative Methods in Historic Monument Research' has been established at the Department of Dosimetry and Application of Ionizing Radiation of the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be, investigated. In the first phase, one investigative method was established for each of the above groups: X-ray fluorescence as the analytic method, thermoluminescence for dating and photogrammetry for surveying. The first results demonstrate the need and usefulness of these methods for investigations in the rich architectural heritage of the Czech Republic.

  10. Comparing Traditional and Crowdsourcing Methods for Pretesting Survey Questions

    Directory of Open Access Journals (Sweden)

    Jennifer Edgar

    2016-10-01

    Full Text Available Cognitive interviewing is a common method used to evaluate survey questions. This study compares traditional cognitive interviewing methods with crowdsourcing, or “tapping into the collective intelligence of the public to complete a task.” Crowdsourcing may provide researchers with access to a diverse pool of potential participants in a very timely and cost-efficient way. Exploratory work found that crowdsourcing participants, with self-administered data collection, may be a viable alternative, or addition, to traditional pretesting methods. Using three crowdsourcing designs (TryMyUI, Amazon Mechanical Turk, and Facebook, we compared the participant characteristics, costs, and quantity and quality of data with traditional laboratory-based cognitive interviews. Results suggest that crowdsourcing and self-administered protocols may be a viable way to collect survey pretesting information, as participants were able to complete the tasks and provide useful information; however, complex tasks may require the skills of an interviewer to administer unscripted probes.

  11. An aerial radiological survey of the Ames Laboratory and surrounding area, Ames, Iowa

    International Nuclear Information System (INIS)

    Maurer, R.J.

    1993-04-01

    An aerial radiological survey of the Ames Laboratory and surrounding area in Ames, Iowa, was conducted during the period July 15--25, 1991. The purpose of the survey was to measure and document the terrestrial radiological environment at the Ames Laboratory and the surrounding area for use in effective environmental management and emergency response planning. The aerial survey was flown at an altitude of 200 feet (61 meters) along a series of parallel lines 350 feet (107 meters) apart. The survey encompassed an area of 36 square miles (93 square kilometers) and included the city of Ames, Iowa, and the Iowa State University. The results are reported as exposure rates at 1 meter above ground level (inferred from the aerial data) in the form of a gamma radiation contour map. Typical background exposure rates were found to vary from 7 to 9 microroentgens per hour (μR/h). No anomalous radiation levels were detected at the Ames Laboratory. However, one anomalous radiation source was detected at an industrial storage yard in the city of Ames. In support of the aerial survey, ground-based exposure rate and soil sample measurements were obtained at several sites within the survey perimeter. The results of the aerial and ground-based measurements were found to agree within the expected uncertainty of ±15%

  12. Environmental Survey preliminary report, Los Alamos National Laboratory, Los Alamos, New Mexico

    International Nuclear Information System (INIS)

    1988-01-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Los Alamos National Laboratory (LANL), conducted March 29, 1987 through April 17, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are outside experts being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the LANL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at the LANL, and interviews with site personnel. The Survey team developed Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by the Idaho National Engineering Laboratory. When completed, the results will be incorporated into the LANL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the Survey for the LANL. 65 refs., 68 figs., 73 tabs

  13. Environmental Survey preliminary report, Los Alamos National Laboratory, Los Alamos, New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Los Alamos National Laboratory (LANL), conducted March 29, 1987 through April 17, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are outside experts being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the LANL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at the LANL, and interviews with site personnel. The Survey team developed Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by the Idaho National Engineering Laboratory. When completed, the results will be incorporated into the LANL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the Survey for the LANL. 65 refs., 68 figs., 73 tabs.

  14. Environmental Survey preliminary report, Laboratory for Energy-Related Health Research, Davis, California

    International Nuclear Information System (INIS)

    1988-03-01

    This report presents the preliminary findings from the first phase of the Survey of the United States Department of Energy (DOE) Laboratory for Energy-Related Health Research (LEHR) at the University of California, Davis (UC Davis), conducted November 16 through 20, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the LEHR. The Survey covers all environmental media and all areas of environmental regulation, and is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations at the LEHR and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by a DOE National Laboratory or a support contractor. When completed, the results will be incorporated into the Environmental Survey Interim Report for the LEHR at UC Davis. The Interim Report will reflect the final determinations of the LEHR Survey. 75 refs., 26 figs., 23 tabs

  15. Laboratory EXAFS using photographic method

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, S K [Government College, Badnawar (Dhar)-454660 (India); Gaur, A; Johari, A; Shrivastava, B D, E-mail: joshisantoshk@yahoo.co [School of Studies in Physics, Vikram University, Ujjain-456010 (India)

    2009-11-15

    Laboratory EXAFS facilities have been used since long. However, EXAFS data analysis has not been reported as yet for the spectra recorded photographically. Though from our laboratory we have been reporting various studies employing X-ray spectrographs using the photographic method of registration of EXAFS spectra, but the data has never been analyzed using the Fourier transformation method and fitting with standards. This paper reports the study of copper metal EXAFS spectra at the K-edge recorded photographically employing a 400 mm curved mica crystal Cauchois type spectrograph with 0.5 kW tungsten target X-ray tube. The data obtained in digital form with the help of a microphotometer has been processed using EXAFS data analysis programs Athena and Artemis. The experimental data for copper metal foil have been fitted with the theoretical standards. The results have been compared with those obtained from another laboratory EXAFS set up employing 12 kW Rigaku rotating anode, Johansson-type spectrometer with Si(311) monochromator crystal and scintillation counter. The results have also been compared with those obtained from SSRL. The parameters obtained for the first two shells from the photographic method are comparable with those obtained from the other two methods. The present work shows that the photographic method of registering EXAFS spectra in laboratory set up using fixed target X-ray tubes can also be used for getting structural information at least for the first two coordination shells.

  16. Laboratory EXAFS using photographic method

    International Nuclear Information System (INIS)

    Joshi, S K; Gaur, A; Johari, A; Shrivastava, B D

    2009-01-01

    Laboratory EXAFS facilities have been used since long. However, EXAFS data analysis has not been reported as yet for the spectra recorded photographically. Though from our laboratory we have been reporting various studies employing X-ray spectrographs using the photographic method of registration of EXAFS spectra, but the data has never been analyzed using the Fourier transformation method and fitting with standards. This paper reports the study of copper metal EXAFS spectra at the K-edge recorded photographically employing a 400 mm curved mica crystal Cauchois type spectrograph with 0.5 kW tungsten target X-ray tube. The data obtained in digital form with the help of a microphotometer has been processed using EXAFS data analysis programs Athena and Artemis. The experimental data for copper metal foil have been fitted with the theoretical standards. The results have been compared with those obtained from another laboratory EXAFS set up employing 12 kW Rigaku rotating anode, Johansson-type spectrometer with Si(311) monochromator crystal and scintillation counter. The results have also been compared with those obtained from SSRL. The parameters obtained for the first two shells from the photographic method are comparable with those obtained from the other two methods. The present work shows that the photographic method of registering EXAFS spectra in laboratory set up using fixed target X-ray tubes can also be used for getting structural information at least for the first two coordination shells.

  17. Environmental survey at the Lucas Heights Research Laboratories. 1983

    International Nuclear Information System (INIS)

    Giles, M.S.; Dudaitis, A.

    1985-12-01

    Results are presented of the environmental survey conducted in the neighbourhood of the Lucas Heights Research Laboratories during 1983. These results are satisfactory. No radioactivity which could have originated from these laboratories was found in samples collected from possible human food chains. All low-level liquid and gaseous waste discharges were within authorised limits. The maximum possible annual dose to the general public from airborne waste discharges during this period is estimated to be less than 0.01 millisieverts, which is 1 per cent of the limit for long-term exposure that is recommended by the National Health and Medical Research Council

  18. National survey on internal quality control for tumour markers in clinical laboratories in China.

    Science.gov (United States)

    Wang, Wei; Zhong, Kun; Yuan, Shuai; He, Falin; Du, Yuxuan; Hu, Zhehui; Wang, Zhiguo

    2018-06-15

    This survey was initiated to obtain knowledge on the current situation of internal quality control (IQC) practice for tumour markers (TMs) in China. Additionally, we tried to acquire the most appropriate quality specifications. This survey was a current status survey. The IQC information had been collected via online questionnaires. All of 1821 clinical laboratories which participated in the 2016 TMs external quality assessment (EQA) programme had been enrolled. The imprecision evaluation criteria were the minimal, desirable, and optimal allowable imprecisions based on biological variations, and 1/3 total allowable error (TEa) and 1/4 TEa. A total of 1628 laboratories answered the questionnaires (89%). The coefficients of variation (CVs) of the IQC of participant laboratories varied greatly from 1% (5 th percentile) to 13% (95 th percentile). More than 82% (82 - 91%) of participant laboratories two types of CVs met 1/3 TEa except for CA 19-9. The percentiles of current CVs were smaller than cumulative CVs. A number of 1240 laboratories (76%) reported their principles and systems used. The electrochemiluminescence was the most used principle (45%) and had the smallest CVs. The performance of laboratories for TMs IQC has yet to be improved. On the basis of the obtained results, 1/3 TEa would be realistic and attainable quality specification for TMs IQC for clinical laboratories in China.

  19. Survey on current status of laboratory test method and experimental consideration for establishing standardized procedure of material containing bentonite. Report of collaboration research between JAEA and CRIEPI (Joint research)

    International Nuclear Information System (INIS)

    Tanai, Kenji; Kikuchi, Hirohito; Nakamura, Kunihiko; Tanaka, Yukihisa; Hironaga, Michihiko

    2010-08-01

    In the current concept of repository for radioactive waste disposal, compacted bentonite as well as bentonite based material will be used as an engineered barrier mainly for inhibiting migration of radioactive nuclides. In most cases, properties of bentonite, such as low permeability etc., are obtained by laboratory tests. However, results of laboratory tests of bentonite often vary considerably even if index parameter, such as effective clay density, is constant. One of the causes of the variability is considered to be lack of standardized method of laboratory test for bentonite. Thus standardization of laboratory test methods for bentonite is needed. So, investigation for establishing standardized laboratory test method of bentonite is conducted based on the results of survey on current status of laboratory test method for bentonite. In particular, the literature survey as well as laboratory tests were conducted to find factors affecting the results of laboratory tests for bentonite and to estimate their degree of influence. The following conclusions are obtained through this study. (1) Hydraulic conductivity test. According to the results of literature survey, it is revealed that constant pressure permeability test and consolidation test are currently used for measuring hydraulic conductivity of bentonite and that (a) hydraulic gradient, (b) local seepage flow between lateral surface of the specimen and lateral wall of the container, (c) water pressure which is applied to the specimen, (d) degree of saturation and (e) size of the specimen possibly affect the results of the constant pressure permeability test, while (f) friction between lateral surface of the specimen and lateral wall of the container accompanied by deformation of the specimen, (g) consolidation pressure together with factors (d), (e) affect the results of the consolidation test. Literature which describes that factors (a), (b) and (e) affect the results of the constant pressure permeability test

  20. Three-year customer satisfaction survey in laboratory medicine in a Chinese university hospital.

    Science.gov (United States)

    Guo, Siqi; Duan, Yifei; Liu, Xiaojuan; Jiang, Yongmei

    2018-04-25

    Customer satisfaction is a key quality indicator of laboratory service. Patients and physicians are the ultimate customers in medical laboratory, and their opinions are essential components in developing a customer-oriented laboratory. A longitudinal investigation of customer satisfaction was conducted through questionnaires. We designed two different questionnaires and selected 1200 customers (600 outpatients and 600 physicians) to assess customer satisfaction every other year from 2012 to 2016. Items with scores satisfaction in 2014 was better, which illustrated our strategy was effective. However, some items remained to be less than 4, so we repeated the survey after modifying questionnaires in 2016. However, the general satisfaction points of the physicians and patients reduced in 2016, which reminded us of some influential factors we had neglected. By using dynamic survey of satisfaction, we can continuously find deficiencies in our laboratory services and take suitable corrective actions, thereby improving our service quality.

  1. Aerial radiological survey of the Fermi National accelerator Laboratory and surrounding area, Batavia, Illinois. Data of survey: 12-14 May 1977

    International Nuclear Information System (INIS)

    Jobst, J.E.

    1981-01-01

    An aerial radiological survey was conducted over the facilities of the Fermi National Accelerator Laboratory (Fermilab) near Batavia, Illinois on 12-14 May 1977. The survey was flown at an altitude of 91 m by a helicopter containing 20 sodium iodide detectors. The line spacing was also 91 m. Enhanced gamma exposure rate levels, which could be attributed to Fermilab operations, were observed at seven locations. One additional anomaly, not related to the Laboratory, was also discovered

  2. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    Science.gov (United States)

    Parrado, G.; Cañón, Y.; Peña, M.; Sierra, O.; Porras, A.; Alonso, D.; Herrera, D. C.; Orozco, J.

    2016-07-01

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  3. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Peña, M., E-mail: mlpena@sgc.gov.co; Sierra, O., E-mail: osierra@sgc.gov.co; Porras, A.; Alonso, D.; Herrera, D. C., E-mail: dherrera@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  4. Environmental Survey preliminary report, Lawrence Berkeley Laboratory, Berkeley, California

    International Nuclear Information System (INIS)

    1988-07-01

    The purpose of this report is to present the preliminary findings made during the Environmental Survey, February 22--29, 1988, at the US Department of Energy (DOE) Lawrence Berkeley Laboratory (LBL) in Berkeley, California. The University of California operates the LBL facility for DOE. The LBL Survey is part of the larger DOE-wide Environmental Survey announced by Secretary John S. Herrington on September 18, 1985. The purpose of this effort is to identify, via ''no fault'' baseline Surveys, existing environmental problems and areas of environmental risk at DOE facilities, and to rank them on a DOE wide basis. This ranking will enable DOE to more effectively establish priorities for addressing environmental problems and allocate the resources necessary to correct them. Because the Survey is ''no fault'' and is not an ''audit,'' it is not designed to identify specific isolated incidents of noncompliance or to analyze environmental management practices. Such incidents and/or management practices will, however, be used in the Survey as a means of identifying existing and potential environmental problems. The LBL Survey was conducted by a multidisciplinary team of technical specialists headed and managed by a Team Leader and Assistant Team Leader from DOE's Office of Environmental Audit. A complete list of the LBL Survey participants and their affiliations is provided in Appendix A. 80 refs., 27 figs., 37 tabs

  5. Environmental Survey preliminary report, Lawrence Berkeley Laboratory, Berkeley, California

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    The purpose of this report is to present the preliminary findings made during the Environmental Survey, February 22--29, 1988, at the US Department of Energy (DOE) Lawrence Berkeley Laboratory (LBL) in Berkeley, California. The University of California operates the LBL facility for DOE. The LBL Survey is part of the larger DOE-wide Environmental Survey announced by Secretary John S. Herrington on September 18, 1985. The purpose of this effort is to identify, via no fault'' baseline Surveys, existing environmental problems and areas of environmental risk at DOE facilities, and to rank them on a DOE wide basis. This ranking will enable DOE to more effectively establish priorities for addressing environmental problems and allocate the resources necessary to correct them. Because the Survey is no fault'' and is not an audit,'' it is not designed to identify specific isolated incidents of noncompliance or to analyze environmental management practices. Such incidents and/or management practices will, however, be used in the Survey as a means of identifying existing and potential environmental problems. The LBL Survey was conducted by a multidisciplinary team of technical specialists headed and managed by a Team Leader and Assistant Team Leader from DOE's Office of Environmental Audit. A complete list of the LBL Survey participants and their affiliations is provided in Appendix A. 80 refs., 27 figs., 37 tabs.

  6. Environmental Survey preliminary report, Oak Ridge National Laboratory (X-10), Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL), X-10 site, conducted August 17 through September 4, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team specialists are outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with ORNL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at ORNL, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by a DOE National Laboratory or a support contractor. When completed, the results will be incorporated into the Environmental Survey Interim Report for ORNL. The Interim Report will reflect the final determinations of the ORNL Survey. 120 refs., 68 figs., 71 tabs.

  7. Environmental Survey preliminary report, Sandia National Laboratories, Livermore, California

    International Nuclear Information System (INIS)

    1988-01-01

    This report contains the preliminary findings based on the first phase of an Environmental Survey at the Department of Energy (DOE) Sandia National Laboratories Livermore (SNLL), located at Livermore, California. The Survey is being conducted by DOE's Office of Environment, Safety and Health. The SNLL Survey is a portion of the larger, comprehensive DOE Environmental Survey encompassing all major operating facilities of DOE. The DOE Environmental Survey is one of a series of initiatives announced on September 18, 1985, by Secretary of Energy, John S. Herrington, to strengthen the environmental, safety, and health programs and activities within DOE. The purpose of the Environmental Survey is to identify, via a ''no fault'' baseline Survey of all the Department's major operating facilities, environmental problems and areas of environmental risk. The identified problem areas will be prioritized on a Department-wide basis in order of importance in 1989. The findings in this report are subject to modification based on the results from the Sampling and Analysis Phase of the Survey. The findings are also subject to modification based on comments from the Albuquerque Operations Office concerning the technical accuracy of the findings. The modified preliminary findings and any other appropriate changes will be incorporated into an Interim Report. The Interim Report will serve as the site-specific source for environmental information generated by the Survey, and ultimately as the primary source of information for the DOE-wide prioritization of environmental problems in the Survey Summary Report. 43 refs., 21 figs., 24 tabs

  8. Environmental Survey preliminary report, Sandia National Laboratories, Livermore, California

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    This report contains the preliminary findings based on the first phase of an Environmental Survey at the Department of Energy (DOE) Sandia National Laboratories Livermore (SNLL), located at Livermore, California. The Survey is being conducted by DOE's Office of Environment, Safety and Health. The SNLL Survey is a portion of the larger, comprehensive DOE Environmental Survey encompassing all major operating facilities of DOE. The DOE Environmental Survey is one of a series of initiatives announced on September 18, 1985, by Secretary of Energy, John S. Herrington, to strengthen the environmental, safety, and health programs and activities within DOE. The purpose of the Environmental Survey is to identify, via a no fault'' baseline Survey of all the Department's major operating facilities, environmental problems and areas of environmental risk. The identified problem areas will be prioritized on a Department-wide basis in order of importance in 1989. The findings in this report are subject to modification based on the results from the Sampling and Analysis Phase of the Survey. The findings are also subject to modification based on comments from the Albuquerque Operations Office concerning the technical accuracy of the findings. The modified preliminary findings and any other appropriate changes will be incorporated into an Interim Report. The Interim Report will serve as the site-specific source for environmental information generated by the Survey, and ultimately as the primary source of information for the DOE-wide prioritization of environmental problems in the Survey Summary Report. 43 refs., 21 figs., 24 tabs.

  9. Aerial radiological survey of the Argonne National Laboratory and surrounding area, Argonne, Illinois. Date of survey: May 1977

    International Nuclear Information System (INIS)

    1982-12-01

    An aerial radiological survey was conducted over the facilities of the Argonne National Laboratory in Argonne, Illinois, on 2 to 13 May 1977. The survey was flown at an altitude of 46 m by a helicopter containing 20 sodium iodide detectors. The line spacing was also 46 m. Enhanced gamma exposure rate levels, which could be attributed to Argonne operations, were observed at many locations

  10. The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Nikolac, Nora; Simundic, Ana-Maria; Kackov, Sanja; Serdar, Tihana; Dorotic, Adrijana; Fumic, Ksenija; Gudasic-Vrdoljak, Jelena; Klenkar, Kornelija; Sambunjak, Jadranka; Vidranski, Valentina

    2015-10-23

    The aim of this work was to evaluate to what extent the scope and content of information provided to patients is standardized across medical biochemistry laboratories in Croatia. Two on-line self-report surveys were sent out: Survey A regarding attitudes on importance of patient preparation and Survey B on the contents of patient preparation instructions. 13/118 laboratories (11%) do not provide written instructions to patients on how to prepare for laboratory testing, and 36 (40%) do not include information about water intake in their instructions. Only half of laboratories provide instructions for prostate-specific antigen (53.8%), female sex hormones (53.7%) and therapeutic drug monitoring (TDM) (52.5%). Inadequate information about fasting status (55.0%) and 24 hour urine collection (77.9%) were frequent errors with high severity and were associated with the greatest potential to cause patient harm. Laboratory professionals in Croatia have a positive attitude towards the importance of patient preparation for laboratory testing. However, the information for laboratory testing is not standardized and frequently lacks guidance for tests related to TDM, coagulation and endocrinology. This study highlights the need for standardized, updated and evidence-based recommendations for patient preparation in order to minimize the risk for patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Survey of 2014 behavioral management programs for laboratory primates in the United States.

    Science.gov (United States)

    Baker, Kate C

    2016-07-01

    The behavioral management of laboratory nonhuman primates in the United States has not been thoroughly characterized since 2003. This article presents the results of a survey behavioral management programs at 27 facilities and covering a total of 59,636 primates, 27,916 housed in indoor cages and 31,720 in group enclosures. The survey included questions regarding program structure, implementation, and methodology associated with social housing, positive reinforcement training, positive human interaction, exercise enclosures, and several categories of inanimate enrichment. The vast majority of laboratory primates are housed socially (83%). Since 2003, the proportion of indoor-housed primates reported to be housed singly has fallen considerably, from 59% to 35% in the facilities surveyed. The use of social housing remains significantly constrained by: 1) research protocol requirements, highlighting the value of closely involved IACUCs for harmonizing research and behavioral management; and 2) the unavailability of compatible social partners, underscoring the necessity of objective analysis of the methods used to foster and maintain compatibility. Positive reinforcement training appears to have expanded and is now used at all facilities responding to the survey. The use of enrichment devices has also increased in the participating facilities. For most behavioral management techniques, concerns over the possibility of negative consequences to animals are expressed most frequently for social housing and destructible enrichment, while skepticism regarding efficacy is limited almost exclusively to sensory enrichment. Behavioral management program staffing has expanded over time in the facilities surveyed, due not only to increased numbers of dedicated behavioral management technicians but also to greater involvement of animal care technicians, suggesting an increase in the integration of behavioral care into animal husbandry. Broad awareness of common practice may assist

  12. A national survey on pediatric critical values used in clinical laboratories across Canada.

    Science.gov (United States)

    Gong, Yanping; Adeli, Khosrow

    2009-11-01

    Notification of critical values to clinical staff is an important post-analytical process in all acute care clinical laboratories. No data are available however on how laboratories obtain or establish critical values, particularly in pediatric settings. This study was designed to examine and compare critical values used for pediatric patients in biochemistry laboratories in Canada and assess potential interlaboratory variability. Fourteen clinical laboratories, including two in pediatric hospitals and twelve in hospitals caring for both children and adults, participated in a survey that included 14 pre-selected STAT chemistry tests and 19 pre-selected therapeutic drug monitoring (TDM) tests. Among fourteen chemistry tests, good agreement was observed for critical values used for sodium and pH at both low and high levels within 14 participant laboratories. Significant interlaboratory variability existed for glucose critical values at the high end, magnesium at high end, and PO2 at the low end. For 19 TDM tests, the majority of laboratories did not have alert values to report values over the therapeutic level but not toxic. For critical values greater than the toxic range, significant variability existed at both trough and peak levels among laboratories surveyed. When asked to provide the source for critical values established at each site, only a limited number of laboratories identified their sources as either internal decision or published references. Although all laboratories have established and routinely use critical values to alert clinical staff, considerable variability exists in both the critical limits reported as well as the source of such values. There is a clear need for new national efforts to standardize pediatric critical value reporting and establish evidence-based critical limits for all medical laboratories across Canada.

  13. A framework for laboratory pre-work based on the concepts, tools and techniques questioning method

    International Nuclear Information System (INIS)

    Huntula, J; Sharma, M D; Johnston, I; Chitaree, R

    2011-01-01

    Learning in the laboratory is different from learning in other contexts because students have to engage with various aspects of the practice of science. They have to use many skills and knowledge in parallel-not only to understand the concepts of physics but also to use the tools and analyse the data. The question arises, how to best guide students' learning in the laboratory. This study is about creating and using questions with a specifically designed framework to aid learning in the laboratory. The concepts, tools and techniques questioning (CTTQ) method was initially designed and used at Mahidol University, Thailand, and was subsequently extended to laboratory pre-work at the University of Sydney. The CTTQ method was implemented in Sydney with 190 first-year students. Three pre-work exercises on a series of electrical experiments were created based on the CTTQ method. The pre-works were completed individually and submitted before the experiment started. Analysed pre-work, surveys and interviews were used to evaluate the pre-work questions in this study. The results indicated that the CTTQ method was successful and the flow in the experiments was better than that in the previous year. At the same time students had difficulty with the last experiment in the sequence and with techniques.

  14. Methicillin-resistant Staphylococcus aureus: laboratory detection methods in use in the Republic of Ireland and Northern Ireland.

    LENUS (Irish Health Repository)

    Humphreys, H

    2002-01-01

    There is no universally agreed laboratory protocol for the detection of methicillin-resistant Staphylococcus aureus (MRSA) and hence a variety of approaches are used. As part of an all-island survey of MRSA in the Republic of Ireland (the South) and Northern Ireland (the North), a questionnaire was circulated to 14 participating laboratories in the North and 49 in the South, to determine the methods used to isolate MRSA from clinical specimens, identify S. aureus and test for susceptibility to methicillin. Almost two-thirds (64%) of laboratories in the North but only 16% of laboratories in the South use enrichment culture. There is heavy reliance on commercial kits to confirm the identification of S. aureus in the South but all laboratories in the North use the staphylocoagulase test. More than 90% of all laboratories use a disc method for susceptibility testing and 71% of laboratories in the North supplement this with the E-test; however, a range of methicillin disk concentrations are in use. There is a need to review current laboratory methods used to detect MRSA, with follow-up audit on their implementation. Additional resources may be needed in some laboratories to comply with revised guidelines, and reference facilities are required to assess new commercially available techniques and to confirm the identification of unusual or difficult strains.

  15. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  16. An aerial radiological survey of the Fermi National Accelerator Laboratory and surrounding area, Batavia, Illinois

    International Nuclear Information System (INIS)

    Fritzsche, A.E.

    1990-11-01

    An aerial radiological gamma survey was conducted over the Fermi National Accelerator Laboratory during 1 through 6 June 1989. Flight lines at 150-foot altitude and 250-foot line spacings assured nearly 100% coverage. The terrestrial exposure at about 6 μR/h was nearly the same as that measured by the previous survey of this area (May 1977). Ten anomalous areas, mostly Na-22 and Mn-54, were detected within buildings and laboratories in the area. Although these locations have changed somewhat from the 1977 survey, the aerial data shows good agreement with the ground-based ion chamber and soil sample data. 7 refs., 15 figs., 1 tab

  17. A survey of Asian life scientists :the state of biosciences, laboratory biosecurity, and biosafety in Asia.

    Energy Technology Data Exchange (ETDEWEB)

    Gaudioso, Jennifer Marie

    2006-02-01

    Over 300 Asian life scientists were surveyed to provide insight into work with infectious agents. This report provides the reader with a more complete understanding of the current practices employed to study infectious agents by laboratories located in Asian countries--segmented by level of biotechnology sophistication. The respondents have a variety of research objectives and study over 60 different pathogens and toxins. Many of the respondents indicated that their work was hampered by lack of adequate resources and the difficulty of accessing critical resources. The survey results also demonstrate that there appears to be better awareness of laboratory biosafety issues compared to laboratory biosecurity. Perhaps not surprisingly, many of these researchers work with pathogens and toxins under less stringent laboratory biosafety and biosecurity conditions than would be typical for laboratories in the West.

  18. Quality assurance practices in Europe: a survey of molecular genetic testing laboratories

    Science.gov (United States)

    Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth

    2012-01-01

    In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (Pquality assurance (Pquality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, Pquality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339

  19. Variability of ethics education in laboratory medicine training programs: results of an international survey.

    Science.gov (United States)

    Bruns, David E; Burtis, Carl A; Gronowski, Ann M; McQueen, Matthew J; Newman, Anthony; Jonsson, Jon J

    2015-03-10

    Ethical considerations are increasingly important in medicine. We aimed to determine the mode and extent of teaching of ethics in training programs in clinical chemistry and laboratory medicine. We developed an on-line survey of teaching in areas of ethics relevant to laboratory medicine. Reponses were invited from directors of training programs who were recruited via email to leaders of national organizations. The survey was completed by 80 directors from 24 countries who directed 113 programs. The largest numbers of respondents directed postdoctoral training of scientists (42%) or physicians (33%), post-masters degree programs (33%), and PhD programs (29%). Most programs (82%) were 2years or longer in duration. Formal training was offered in research ethics by 39%, medical ethics by 31%, professional ethics by 24% and business ethics by 9%. The number of reported hours of formal training varied widely, e.g., from 0 to >15h/year for research ethics and from 0 to >15h for medical ethics. Ethics training was required and/or tested in 75% of programs that offered training. A majority (54%) of respondents reported plans to add or enhance training in ethics; many indicated a desire for online resources related to ethics, especially resources with self-assessment tools. Formal teaching of ethics is absent from many training programs in clinical chemistry and laboratory medicine, with heterogeneity in the extent and methods of ethics training among the programs that provide the training. A perceived need exists for online training tools, especially tools with self-assessment components. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. [Resistance of gonococci in the Netherlands; results of a survey of medical microbiology laboratories].

    Science.gov (United States)

    van Loo, I H M; Spaargaren, J; van de Laar, M J W

    2005-05-28

    To collect information about the incidence ofgonorrhoea and gonococcal resistance in the Netherlands. A questionnaire was sent to 39 medical microbiology laboratories to obtain information on current diagnostics and the susceptibility testing method, and on the number of positive results and the susceptibility pattern of gonococcal isolates in 2002 and 2003 (up to and including November). 32 laboratories participated in this survey. 13 laboratories used culture alone and 19 laboratories used culture and/or a molecular test. Gonorrhoea was diagnosed 2,666 times in 2002 and 2,190 times in 2003, with an incidence of 33.5 and 27.0 per 100,000 inhabitants, respectively. The rate of resistance to beta-lactam antibiotics (penicillin and amoxicillin) was 12.2% and 10.7% in 2002 and 2003, respectively, and the rates of resistance to tetracycline were 18.5% and 20.6%. An increase in the resistance to quinolones was observed from 6.6% in 2002 to 9.5% in 2003. Resistance to cephalosporins was low (0.5% in 2002 and 1.2% in 2003). Furthermore, regional differences in susceptibility were found within the Netherlands. The observed gonococcal incidence and resistance form the basis for a gonorrhoea prevention and treatment programme in the Netherlands.

  1. Determinants of Pediatric Echocardiography Laboratory Productivity: Analysis from the Second Survey of the American Society of Echocardiography Committee on Echocardiography Laboratory Productivity.

    Science.gov (United States)

    Srivastava, Shubhika; Allada, Vivekanand; Younoszai, Adel; Lopez, Leo; Soriano, Brian D; Fleishman, Craig E; Van Hoever, Andrea M; Lai, Wyman W

    2016-10-01

    The American Society of Echocardiography Committee on Pediatric Echocardiography Laboratory Productivity aimed to study factors that could influence the clinical productivity of physicians and sonographers and assess longitudinal trends for the same. The first survey results indicated that productivity correlated with the total volume of echocardiograms. Survey questions were designed to assess productivity for (1) physician full-time equivalent (FTE) allocated to echocardiography reading (echocardiograms per physician FTE per day), (2) sonographer FTE (echocardiograms per sonographer FTE per year), and (3) machine utilization (echocardiograms per machine per year). Questions were also posed to assess work flow and workforce. For fiscal year 2013 or academic year 2012-2013, the mean number of total echocardiograms-including outreach, transthoracic, fetal, and transesophageal echocardiograms-per physician FTE per day was 14.3 ± 5.9, the mean number of echocardiograms per sonographer FTE per year was 1,056 ± 441, and the mean number of echocardiograms per machine per year was 778 ± 303. Both physician and sonographer productivity was higher at high-volume surgical centers and with echocardiography slots scheduled concordantly with clinic visits. Having an advanced imaging fellow and outpatient sedation correlated negatively with clinical laboratory productivity. Machine utilization was greater in laboratories with higher sonographer and physician productivity and lower for machines obtained before 2009. Measures of pediatric echocardiography laboratory staff productivity and machine utilization were shown to correlate positively with surgical volume, total echocardiography volumes, and concordant echocardiography scheduling; the same measures correlated negatively with having an advanced imaging fellow and outpatient sedation. There has been no significant change in staff productivity noted over two Committee on Pediatric Echocardiography Laboratory

  2. Salaries and compensation practices in public health, environmental, and agricultural laboratories: findings from a 2010 national survey.

    Science.gov (United States)

    DeBoy, John M; Boulton, Matthew L; Carpenter, David F

    2013-01-01

    The public health, environmental, and agricultural laboratory (PHEAL) workforce is a key component of the public health infrastructure. The national laboratory workforce faces an ongoing challenge of recruitment and retention of workers often related to pay and other compensation issues. To collect information on laboratory salaries and laboratory compensation practices using a national compensation survey targeting the PHEAL workforce. Seventy-three of 109 (67%) PHEAL directors in the 50 states and District of Columbia collectively employ 3723/4830 (77%) PHEAL employees in the United States. A standardized survey was developed and administered in 2010. Compensation data were compiled by job classification, geographic region, laboratory gross operating budget size, laboratory staff size, and laboratory type. Laboratory staff size ranged from 3 to 327 individuals (mean = 74 and median = 51). Median base salaries were lowest in the Southwest and South and highest in the Mountain and Pacific regions. Mean and median laboratory gross operating budgets for all participating PHEALs were $8 609 238 and $5 671 500, respectively. Extra cash compensation, used by 8 of 60 (13.3%) PHEALs, was more likely to go to a scientist-manager or scientist-supervisor. In 2010, a standardized national compensation survey of technical and scientific public health employees working in 73 PHEALs was effective in collecting previously unavailable data about laboratory salaries, laboratory budgets, and payroll practices. Laboratory salaries varied by geographic region and there was an uneven distribution of extra cash compensation among job classifications. The compensation data collected may be useful in characterizing and improving laboratory salary structures and practices to better support workforce recruitment and retention.

  3. A Novel Simulation Technician Laboratory Design: Results of a Survey-Based Study.

    Science.gov (United States)

    Ahmed, Rami; Hughes, Patrick G; Friedl, Ed; Ortiz Figueroa, Fabiana; Cepeda Brito, Jose R; Frey, Jennifer; Birmingham, Lauren E; Atkinson, Steven Scott

    2016-03-16

    OBJECTIVE : The purpose of this study was to elicit feedback from simulation technicians prior to developing the first simulation technician-specific simulation laboratory in Akron, OH. Simulation technicians serve a vital role in simulation centers within hospitals/health centers around the world. The first simulation technician degree program in the US has been approved in Akron, OH. To satisfy the requirements of this program and to meet the needs of this special audience of learners, a customized simulation lab is essential. A web-based survey was circulated to simulation technicians prior to completion of the lab for the new program. The survey consisted of questions aimed at identifying structural and functional design elements of a novel simulation center for the training of simulation technicians. Quantitative methods were utilized to analyze data. Over 90% of technicians (n=65) think that a lab designed explicitly for the training of technicians is novel and beneficial. Approximately 75% of respondents think that the space provided appropriate audiovisual (AV) infrastructure and space to evaluate the ability of technicians to be independent. The respondents think that the lab needed more storage space, visualization space for a large number of students, and more space in the technical/repair area. CONCLUSIONS : A space designed for the training of simulation technicians was considered to be beneficial. This laboratory requires distinct space for technical repair, adequate bench space for the maintenance and repair of simulators, an appropriate AV infrastructure, and space to evaluate the ability of technicians to be independent.

  4. Aerial radiological survey of the Idaho National Engineering Laboratory, Idaho Falls, Idaho. Date of survey: June 1982

    International Nuclear Information System (INIS)

    1984-02-01

    An aerial radiological survey of the Idaho National Engineering Laboratory (INEL) was conducted during June 1982 by EG and G Energy Measurements, Inc. for the United States Department of Energy (DOE). The survey consisted of airborne measurements of both natural and man-made gamma radiation from the terrain surface in and around the INEL site. These measurements allowed an estimate of the distribution of isotopic concentrations in the survey area. Results are reported as isopleths superimposed on maps and photographs of the area. Gamma ray energy spectra are also presented for the net man-made radionuclides. The survey was designed to cover all of the area within a 2 mile radius of any facility at the INEL. Several areas of man-made activity were detected. These areas are all known working or storage areas which are associated with normal operations at the INEL. 3 references, 48 figures, 5 tables

  5. National Cooperative Soil Survey (NCSS) Laboratory Data, NCSS Lab Data Mart Point Dataset

    Data.gov (United States)

    Department of Agriculture — This layer represents the National Cooperative Soil Survey laboratory data of soil properties for soil samples taken at sites or points on the Earth’s globe – mainly...

  6. Nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia.

    Science.gov (United States)

    Krleza, Jasna Lenicek

    2014-01-01

    Capillary sampling is increasingly used to obtain blood for laboratory tests in volumes as small as necessary and as non-invasively as possible. Whether capillary blood sampling is also frequent in Croatia, and whether it is performed according to international laboratory standards is unclear. All medical laboratories that participate in the Croatian National External Quality Assessment Program (N = 204) were surveyed on-line to collect information about the laboratory's parent institution, patient population, types and frequencies of laboratory tests based on capillary blood samples, choice of reference intervals, and policies and procedures specifically related to capillary sampling. Sampling practices were compared with guidelines from the Clinical and Laboratory Standards Institute (CLSI) and the World Health Organization (WHO). Of the 204 laboratories surveyed, 174 (85%) responded with complete questionnaires. Among the 174 respondents, 155 (89%) reported that they routinely perform capillary sampling, which is carried out by laboratory staff in 118 laboratories (76%). Nearly half of respondent laboratories (48%) do not have a written protocol including order of draw for multiple sampling. A single puncture site is used to provide capillary blood for up to two samples at 43% of laboratories that occasionally or regularly perform such sampling. Most respondents (88%) never perform arterialisation prior to capillary blood sampling. Capillary blood sampling is highly prevalent in Croatia across different types of clinical facilities and patient populations. Capillary sampling procedures are not standardised in the country, and the rate of laboratory compliance with CLSI and WHO guidelines is low.

  7. Customer satisfaction in anatomic pathology. A College of American Pathologists Q-Probes study of 3065 physician surveys from 94 laboratories.

    Science.gov (United States)

    Zarbo, Richard J; Nakhleh, Raouf E; Walsh, Molly

    2003-01-01

    Measurement of physicians' and patients' satisfaction with laboratory services has recently become a requirement of health care accreditation agencies in the United States. To our knowledge, this is the first customer satisfaction survey of anatomic pathology services to provide a standardized tool and benchmarks for subsequent measures of satisfaction. This Q-Probes study assessed physician satisfaction with anatomic pathology laboratory services and sought to determine characteristics that correlate with a high level of physician satisfaction. In January 2001, each laboratory used standardized survey forms to assess physician customer satisfaction with 10 specific elements of service in anatomic pathology and an overall satisfaction rating based on a scale of rankings from a 5 for excellent to a 1 for poor. Data from up to 50 surveys returned per laboratory were compiled and analyzed by the College of American Pathologists. A general questionnaire collected information about types of services offered and each laboratory's quality assurance initiatives to determine characteristics that correlate with a high level of physician satisfaction. Hospital-based laboratories in the United States (95.8%), as well as others from Canada and Australia. Ninety-four voluntary subscriber laboratories in the College of American Pathologists Q-Probes quality improvement program participated in this survey. Roughly 70% of respondents were from hospitals with occupied bedsizes of 300 or less, 65% were private nonprofit institutions, just over half were located in cities, one third were teaching hospitals, and 19% had pathology residency training programs. Overall physician satisfaction with anatomic pathology and 10 selected aspects of the laboratory service (professional interaction, diagnostic accuracy, pathologist responsiveness to problems, pathologist accessibility for frozen section, tumor board presentations, courtesy of secretarial and technical staff, communication of

  8. From customer satisfaction survey to corrective actions in laboratory services in a university hospital.

    Science.gov (United States)

    Oja, Paula I; Kouri, Timo T; Pakarinen, Arto J

    2006-12-01

    To find out the satisfaction of clinical units with laboratory services in a university hospital, to point out the most important problems and defects in services, to carry out corrective actions, and thereafter to identify the possible changes in satisfaction. and Senior physicians and nurses-in-charge of the clinical units at Oulu University Hospital, Finland. Customer satisfaction survey using a questionnaire was carried out in 2001, indicating the essential aspects of laboratory services. Customer-specific problems were clarified, corrective actions were performed, and the survey was repeated in 2004. In 2001, the highest dissatisfaction rates were recorded for computerized test requesting and reporting, turnaround times of tests, and the schedule of phlebotomy rounds. The old laboratory information system was not amenable to major improvements, and it was renewed in 2004-05. Several clinical units perceived turnaround times to be long, because the tests were ordered as routine despite emergency needs. Instructions about stat requesting were given to these units. However, no changes were evident in the satisfaction level in the 2004 survey. Following negotiations with the clinics, phlebotomy rounds were re-scheduled. This resulted in a distinct increase in satisfaction in 2004. Satisfaction survey is a screening tool that identifies topics of dissatisfaction. Without further clarifications, it is not possible to find out the specific problems of customers and to undertake targeted corrective actions. Customer-specific corrections are rarely seen as improvements in overall satisfaction rates.

  9. [Bacterial identification methods in the microbiology laboratory].

    Science.gov (United States)

    Bou, Germán; Fernández-Olmos, Ana; García, Celia; Sáez-Nieto, Juan Antonio; Valdezate, Sylvia

    2011-10-01

    In order to identify the agent responsible of the infectious process and understanding the pathogenic/pathological implications, clinical course, and to implement an effective antimicrobial therapy, a mainstay in the practice of clinical microbiology is the allocation of species to a microbial isolation. In daily routine practice microbiology laboratory phenotypic techniques are applied to achieve this goal. However, they have some limitations that are seen more clearly for some kinds of microorganism. Molecular methods can circumvent some of these limitations, although its implementation is not universal. This is due to higher costs and the level of expertise required for thei implementation, so molecular methods are often centralized in reference laboratories and centers. Recently, proteomics-based methods made an important breakthrough in the field of diagnostic microbiology and will undoubtedly have a major impact on the future organization of the microbiology services. This paper is a short review of the most noteworthy aspects of the three bacterial identification methods described above used in microbiology laboratories. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  10. National survey on turnaround time of clinical biochemistry tests in 738 laboratories in China.

    Science.gov (United States)

    Zhang, Xiaoyan; Fei, Yang; Wang, Wei; Zhao, Haijian; Wang, Minqi; Chen, Bingquan; Zhou, Jie; Wang, Zhiguo

    2018-02-01

    This survey was initiated to estimate the current status of turnaround time (TAT) monitoring of clinical biochemistry in China, provide baseline data for establishment of quality specifications and analyze the impact factors of TAT. 738 laboratories were included. Questionnaires involved general information and data of related indicators of TAT during 1 week were provided to participating laboratories. Nine quality indicators were covered, which were medians, 90th and outlier rates of pre-examination, examination, and post-examination TAT. The 25th percentile, median, and 75th percentile of TATs were calculated as optimum, desirable, and minimum quality specifications. Percentages and sigma values were used to describe the outlier rates. Mann-Whitney and Kruskal-Wallis tests were used to identify the potential impacts of TAT. Response rate of this survey was 46.44%. More than 50% of the laboratories indicated they had set up target TATs in three time intervals and monitored TATs generally. The post-examination TAT of most laboratories was 0min, while the pre-examination and examination TAT varied. Sigma values of outlier rates for 45%~60% of laboratories were above 4, while 15%~20% of labs whose sigma values were below 3. Group comparisons suggested nurse or mechanical pipeline transportation, link laboratory information system with hospital information system, and using computer reporting instead of printing report were related to shorter TATs. Despite of the remarkable progresses of TATs in China, there was also room to improve. Laboratories should strengthen the construction of information systems, identify reasons for TAT delay to improve the service quality continuously. © 2017 Wiley Periodicals, Inc.

  11. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  12. Comparison of Satellite Surveying to Traditional Surveying Methods for the Resources Industry

    Science.gov (United States)

    Osborne, B. P.; Osborne, V. J.; Kruger, M. L.

    Modern ground-based survey methods involve detailed survey, which provides three-space co-ordinates for surveyed points, to a high level of accuracy. The instruments are operated by surveyors, who process the raw results to create survey location maps for the subject of the survey. Such surveys are conducted for a location or region and referenced to the earth global co- ordinate system with global positioning system (GPS) positioning. Due to this referencing the survey is only as accurate as the GPS reference system. Satellite survey remote sensing utilise satellite imagery which have been processed using commercial geographic information system software. Three-space co-ordinate maps are generated, with an accuracy determined by the datum position accuracy and optical resolution of the satellite platform.This paper presents a case study, which compares topographic surveying undertaken by traditional survey methods with satellite surveying, for the same location. The purpose of this study is to assess the viability of satellite remote sensing for surveying in the resources industry. The case study involves a topographic survey of a dune field for a prospective mining project area in Pakistan. This site has been surveyed using modern surveying techniques and the results are compared to a satellite survey performed on the same area.Analysis of the results from traditional survey and from the satellite survey involved a comparison of the derived spatial co- ordinates from each method. In addition, comparisons have been made of costs and turnaround time for both methods.The results of this application of remote sensing is of particular interest for survey in areas with remote and extreme environments, weather extremes, political unrest, poor travel links, which are commonly associated with mining projects. Such areas frequently suffer language barriers, poor onsite technical support and resources.

  13. Automation of the National Water Quality Laboratories, U. S. Geological Survey. I. Description of laboratory functions and definition of the automation project

    Energy Technology Data Exchange (ETDEWEB)

    Morris, W.F.; Ames, H.S.

    1977-07-01

    In January 1976, the Water Resources Division of the U.S. Geological Survey asked Lawrence Livermore Laboratory to conduct a feasibility study for automation of the National Water Quality (NWQ) Laboratory in Denver, Colorado (formerly Denver Central Laboratory). Results of the study were published in the Feasibility Study for Automation of the Central Laboratories, Lawrence Livermore Laboratory, Rept. UCRL-52001 (1976). Because the present system for processing water samples was found inadequate to meet the demands of a steadily increasing workload, new automation was recommended. In this document we present details necessary for future implementation of the new system, as well as descriptions of current laboratory automatic data processing and analytical facilities to better define the scope of the project and illustrate what the new system will accomplish. All pertinent inputs, outputs, and other operations that define the project are shown in functional designs.

  14. Automation of the National Water Quality Laboratories, U.S. Geological Survey. I. Description of laboratory functions and definition of the automation project

    International Nuclear Information System (INIS)

    Morris, W.F.; Ames, H.S.

    1977-01-01

    In January 1976, the Water Resources Division of the U.S. Geological Survey asked Lawrence Livermore Laboratory to conduct a feasibility study for automation of the National Water Quality (NWQ) Laboratory in Denver, Colorado (formerly Denver Central Laboratory). Results of the study were published in the Feasibility Study for Automation of the Central Laboratories, Lawrence Livermore Laboratory, Rept. UCRL-52001 (1976). Because the present system for processing water samples was found inadequate to meet the demands of a steadily increasing workload, new automation was recommended. In this document we present details necessary for future implementation of the new system, as well as descriptions of current laboratory automatic data processing and analytical facilities to better define the scope of the project and illustrate what the new system will accomplish. All pertinent inputs, outputs, and other operations that define the project are shown in functional designs

  15. Final Report Bald and Golden Eagle Territory Surveys for the Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Fratanduono, M. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-11-25

    Garcia and Associates (GANDA) was contracted by the Lawrence Livermore National Laboratory (LLNL) to conduct surveys for bald eagles (Haliaeetus leucocephalus) and golden eagles (Aquila chrysaetos) at Site 300 and in the surrounding area out to 10-miles. The survey effort was intended to document the boundaries of eagle territories by careful observation of eagle behavior from selected viewing locations throughout the study area.

  16. Collaborative Testing in Practical Laboratories: An Effective Teaching-Learning Method in Histology.

    Science.gov (United States)

    Guo, Yuping; Li, Enzhong

    2016-01-01

    This article presents an experimental teaching and learning program used in histology with first-year students in the second term in the Faculty of Biology at Huanghuai University, China. Eighty-six students were divided randomly into two groups (n=43 per group). Tests were conducted at the end of each practical laboratory (10 laboratories in total) in which collaborative testing was used in the experimental group and traditional testing in the control group. To assess achievement, a final examination in histology was carried out at the end of the course. To determine students' attitude to the teaching styles, a questionnaire survey was conducted at the end of the term. Results showed that students preferred the collaborative testing format. In the experimental group, students' scores were significantly higher than those of students in the control group in final examinations. These findings indicate that collaborative testing enhances student learning and understanding of the material taught, and suggest that collaborative testing is an effective teaching-learning method in histology.

  17. Laboratory compliance with the American Society of Clinical Oncology/college of American Pathologists guidelines for human epidermal growth factor receptor 2 testing: a College of American Pathologists survey of 757 laboratories.

    Science.gov (United States)

    Nakhleh, Raouf E; Grimm, Erin E; Idowu, Michael O; Souers, Rhona J; Fitzgibbons, Patrick L

    2010-05-01

    To ensure quality human epidermal growth receptor 2 (HER2) testing in breast cancer, the American Society of Clinical Oncology/College of American Pathologists guidelines were introduced with expected compliance by 2008. To assess the effect these guidelines have had on pathology laboratories and their ability to address key components. In late 2008, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program. It included questions regarding pathology practice characteristics and assay validation using fluorescence in situ hybridization or another IHC laboratory assay and assessed pathologist HER2 scoring competency. Of the 907 surveys sent, 757 (83.5%) were returned. The median laboratory accessioned 15 000 cases and performed 190 HER2 tests annually. Quantitative computer image analysis was used by 33% of laboratories. In-house fluorescence in situ hybridization was performed in 23% of laboratories, and 60% of laboratories addressed the 6- to 48-hour tissue fixation requirement by embedding tissue on the weekend. HER2 testing was performed on the initial biopsy in 40%, on the resection specimen in 6%, and on either in 56% of laboratories. Testing was validated with only fluorescence in situ hybridization in 47% of laboratories, whereas 10% of laboratories used another IHC assay only; 13% used both assays, and 12% and 15% of laboratories had not validated their assays or chose "not applicable" on the survey question, respectively. The 90% concordance rate with fluorescence in situ hybridization results was achieved by 88% of laboratories for IHC-negative findings and by 81% of laboratories for IHC-positive cases. The 90% concordance rate for laboratories using another IHC assay was achieved by 80% for negative findings and 75% for positive cases. About 91% of laboratories had a pathologist competency assessment program. This survey demonstrates the extent and characteristics of HER2 testing. Although some American Society of

  18. Implementation of 5S Method for Ergonomic Laboratory

    Science.gov (United States)

    Dila Sari, Amarria; Ilma Rahmillah, Fety; Prabowo Aji, Bagus

    2017-06-01

    This article discusses 5S implementation in Work System Design and Ergonomic Laboratory, Department of Industrial Engineering, Islamic University of Indonesia. There are some problems related to equipment settings for activity involving students such as files which is accumulated over the previous year practicum, as well as the movement of waste in the form of time due to the placement of goods that do not fit. Therefore, this study aims to apply the 5S method in DSK & E laboratory to facilitate the work processes and reduce waste. The project is performed by laboratory management using 5S methods in response to continuous improvement (Kaizen). Moreover, some strategy and suggestions are promoted to impose 5S system within the laboratory. As a result, the tidiness and cleanliness can be achieved that lead to the great performance of laboratory users. Score assessment before implementing 5S DSKE laboratory is at 64 (2.56) while the score after implementation is 32 (1.28) and shows an improvement of 50%. This has implications for better use in the laboratory area, save time when looking for tools and materials due to its location and good visual control, as well as improving the culture and spirit of ‘5S’ on staff regarding better working environment

  19. The management of clinical laboratories in Europe: a FESCC survey. Forum of the European Societies of Clinical Chemistry and Laboratory Medicine.

    Science.gov (United States)

    de Kieviet, Wim; Blaton, Victor; Kovacs, Gabor L; Palicka, Vladimir; Pulkki, Kari

    2002-03-01

    The professional duties of the specialists in clinical chemistry differ from country to country in Europe. One of the main goals of the Strategic Plan of the Forum of the European Societies of Clinical Chemistry and Laboratory Medicine (FESCC; IFCC-Europe) is to promote a high scientific and professional standard in the field of clinical chemistry and laboratory medicine in Europe. This can be stimulated by the knowledge of the local conditions in each country and by striving towards a strong and harmonised position in all the European countries. In order to enhance the knowledge of the managerial situation of the specialists in clinical chemistry in Europe, FESCC launched a survey in September 2000. This survey provides information about the position of the specialists in clinical chemistry in the various disciplines in the medical laboratories and in hospitals, and about the advisory tasks and the managerial education during the post-graduate training in clinical chemistry. Of the 35 FESCC member countries 33 have participated in the survey (94%). The results show a rather heterogeneous situation in Europe caused by the local historical developments, the differences in academic background and the relative numbers of private and physicians' office laboratories. Large differences exist between the European countries in the disciplines of laboratory medicine that are headed by a specialist in clinical chemistry. In the different countries the clinical chemistry laboratories are headed by specialists in clinical chemistry in between 20% and 100% of the laboratories. The haematology, immunology, microbiology, therapeutic drug monitoring, molecular biology and haemostasis laboratories and departments of blood banking are headed by specialists in clinical chemistry in between 0% and 100% of the laboratories. The responsibilities for the various managerial tasks of the specialists in clinical chemistry show no uniformity in Europe. In the majority of the countries the

  20. Immunohistochemistry practices of cytopathology laboratories: a survey of participants in the College of American Pathologists Nongynecologic Cytopathology Education Program.

    Science.gov (United States)

    Fischer, Andrew H; Schwartz, Mary R; Moriarty, Ann T; Wilbur, David C; Souers, Rhona; Fatheree, Lisa; Booth, Christine N; Clayton, Amy C; Kurtyz, Daniel F I; Padmanabhan, Vijayalakshmi; Crothers, Barbara A

    2014-09-01

    Immunohistochemistry (IHC) is important for cytology but poses special challenges because preanalytic conditions may differ from the conditions of IHC-positive controls. To broadly survey cytology laboratories to quantify preanalytic platforms for cytology IHC and identify problems with particular platforms or antigens. To discover how validation guidelines for HER2 testing have affected cytology. A voluntary survey of cytology IHC practices was sent to 1899 cytology laboratories participating in the College of American Pathologists Nongynecologic Cytopathology Education Program in the fall of 2009. A total of 818 laboratories (43%) responded to the survey by April 2010. Three hundred fourty-five of 791 respondents (44%) performed IHC on cytology specimens. Seventeen different fixation and processing platforms prior to antibody reaction were reported. A total of 59.2% of laboratories reported differences between the platforms for cytology specimens and positive controls, but most (155 of 184; 84%) did not alter antibody dilutions or antigen retrieval for cytology IHC. When asked to name 2 antibodies for which staining conditions differed between cytology and surgical samples, there were 18 responses listing 14 antibodies. A total of 30.6% of laboratories performing IHC offered HER2 testing before publication of the 2007 College of American Pathologists/American Society of Clinical Oncologists guidelines, compared with 33.6% afterward, with increased performance of testing by reference laboratories. Three laboratories validated a nonformalin HER2 platform. The platforms for cytology IHC and positive controls differ for most laboratories, yet conditions are uncommonly adjusted for cytology specimens. Except for the unsuitability of air-dried smears for HER2 testing, the survey did not reveal evidence of systematic problems with any antibody or platform.

  1. Y-STR frequency surveying method

    DEFF Research Database (Denmark)

    Willuweit, Sascha; Caliebe, Amke; Andersen, Mikkel Meyer

    2011-01-01

    Reasonable formalized methods to estimate the frequencies of DNA profiles generated from lineage markers have been proposed in the past years and were discussed in the forensic community. Recently, collections of population data on the frequencies of variations in Y chromosomal STR profiles have...... reached a new quality with the establishment of the comprehensive neatly quality-controlled reference database YHRD. Grounded on such unrivalled empirical material from hundreds of populations studies the core assumption of the Haplotype Frequency Surveying Method originally described 10 years ago can...... be tested and improved. Here we provide new approaches to calculate the parameters used in the frequency surveying method: a maximum likelihood estimation of the regression parameters (r1, r2, s1 and s2) and a revised Frequency Surveying framework with variable binning and a database preprocessing to take...

  2. Results of a survey on accident and safety analysis codes, benchmarks, verification and validation methods

    International Nuclear Information System (INIS)

    Lee, A.G.; Wilkin, G.B.

    1996-03-01

    During the 'Workshop on R and D needs' at the 3rd Meeting of the International Group on Research Reactors (IGORR-III), the participants agreed that it would be useful to compile a survey of the computer codes and nuclear data libraries used in accident and safety analyses for research reactors and the methods various organizations use to verify and validate their codes and libraries. Five organizations, Atomic Energy of Canada Limited (AECL, Canada), China Institute of Atomic Energy (CIAE, People's Republic of China), Japan Atomic Energy Research Institute (JAERI, Japan), Oak Ridge National Laboratories (ORNL, USA), and Siemens (Germany) responded to the survey. The results of the survey are compiled in this report. (author) 36 refs., 3 tabs

  3. National Survey on Internal Quality Control for HbA(1c) Analytical Instruments in 331 Hospital Laboratories of China.

    Science.gov (United States)

    Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo

    2015-01-01

    The narrow gap of HbA1 value of mass fraction between "normal" (control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.

  4. Performance in Measurement of Serum Cystatin C by Laboratories Participating in the College of American Pathologists 2014 CYS Survey.

    Science.gov (United States)

    Eckfeldt, John H; Karger, Amy B; Miller, W Greg; Rynders, Gregory P; Inker, Lesley A

    2015-07-01

    Cystatin C is becoming an increasingly popular biomarker for estimating glomerular filtration rate, and accurate measurements of cystatin C concentrations are necessary for accurate estimates of glomerular filtration rate. To assess the accuracy of cystatin C concentration measurements in laboratories participating in the College of American Pathologists CYS Survey. Two fresh frozen serum pools, the first from apparently healthy donors and the second from patients with chronic kidney disease, were prepared and distributed to laboratories participating in the CYS Survey along with the 2 usual processed human plasma samples. Target values were established for each pool by using 2 immunoassays and ERM DA471/IFCC international reference material. For the normal fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.960 mg/L), the all-method mean (SD, % coefficient of variation [CV]) reported by all of the 123 reporting laboratories was 0.894 mg/L (0.128 mg/L, 14.3%). For the chronic kidney disease pool (ERM-DA471/IFCC-traceable target of 2.37 mg/L), the all-method mean (SD, %CV) was 2.258 mg/L (0.288 mg/L, 12.8%). There were substantial method-specific biases (mean milligram per liter reported for the normal pool was 0.780 for Siemens, 0.870 for Gentian, 0.967 for Roche, 1.061 for Diazyme, and 0.970 for other/not specified reagents; and mean milligram per liter reported for the chronic kidney disease pool was 2.052 for Siemens, 2.312 for Gentian, 2.247 for Roche, 2.909 for Diazyme, and 2.413 for other/not specified reagents). Manufacturers need to improve the accuracy of cystatin C measurement procedures if cystatin C is to achieve its full potential as a biomarker for estimating glomerular filtration rate.

  5. Method Validation Procedure in Gamma Spectroscopy Laboratory

    International Nuclear Information System (INIS)

    El Samad, O.; Baydoun, R.

    2008-01-01

    The present work describes the methodology followed for the application of ISO 17025 standards in gamma spectroscopy laboratory at the Lebanese Atomic Energy Commission including the management and technical requirements. A set of documents, written procedures and records were prepared to achieve the management part. The technical requirements, internal method validation was applied through the estimation of trueness, repeatability , minimum detectable activity and combined uncertainty, participation in IAEA proficiency tests assure the external method validation, specially that the gamma spectroscopy lab is a member of ALMERA network (Analytical Laboratories for the Measurements of Environmental Radioactivity). Some of these results are presented in this paper. (author)

  6. Methods of removing uranium from drinking water. 1. A literature survey. 2. Present municipal water treatment and potential removal methods

    International Nuclear Information System (INIS)

    Drury, J.S.; Michelson, D.; Ensminger, J.T.; Lee, S.Y.; White, S.K.

    1982-12-01

    Literature was searched for methods of removing uranium from drinking water. U.S. manufacturers and users of water-treatment equipment and products were also contacted regarding methods of removing uranium from potable water. Based on the results of these surveys, it was recommended that untreated, partially treated, and finished water samples from municipal water-treatment facilities be analyzed to determine the extent of removal of uranium by presently used procedures, and that additional laboratory studies be performed to determine what changes are needed to maximize the effectiveness of treatments that are already in use in existing water-treatment plants

  7. Perceptions of a medical microbiology service: a survey of laboratory users.

    Science.gov (United States)

    Morgan, M S

    1995-10-01

    To ascertain the perception of laboratory users regarding the quality of the medical microbiology services in a district general hospital. Detailed questionnaires were circulated to all clinicians in the locality, with headings covering the quality of medical advice provided, the availability of information on specimen collection, format of request forms, specimen transport arrangements, turnaround times, the quality and need for interpretative advice, and the overall impression of the quality of the services provided. Two hundred and thirty five replies were received, giving a response rate of 69%. Transportation of specimens and communication of reports were identified as priority areas for improvement. The overall quality of the service was perceived as satisfactory, although areas were identified where substantial improvements could be made, some at little or no cost to the laboratory. The survey focused clinicians' attention on the service, raised the profile of the laboratory, and resulted in improved communications and a better understanding of customer needs. Overall, the exercise was felt to be extremely useful, and worthwhile repeating to gauge the effect of the changes instituted as a result.

  8. What do physicians tell laboratories when requesting tests? A multi-method examination of information supplied to the microbiology laboratory before and after the introduction of electronic ordering.

    Science.gov (United States)

    Georgiou, Andrew; Prgomet, Mirela; Toouli, George; Callen, Joanne; Westbrook, Johanna

    2011-09-01

    The provision of relevant clinical information on pathology requests is an important part of facilitating appropriate laboratory utilization and accurate results interpretation and reporting. (1) To determine the quantity and importance of handwritten clinical information provided by physicians to the Microbiology Department of a hospital pathology service; and (2) to examine the impact of a Computerized Provider Order Entry (CPOE) system on the nature of clinical information communication to the laboratory. A multi-method and multi-stage investigation which included: (a) a retrospective audit of all handwritten Microbiology requests received over a 1-month period in the Microbiology Department of a large metropolitan teaching hospital; (b) the administration of a survey to laboratory professionals to investigate the impact of different clinical information on the processing and/or interpretation of tests; (c) an expert panel consisting of medical staff and senior scientists to assess the survey findings and their impact on pathology practice and patient care; and (d) a comparison of the provision and value of clinical information before CPOE, and across 3 years after its implementation. The audit of handwritten requests found that 43% (n=4215) contained patient-related clinical information. The laboratory survey showed that 97% (84/86) of the different types of clinical information provided for wound specimens and 86% (43/50) for stool specimens were shown to have an effect on the processing or interpretation of the specimens by one or more laboratory professionals. The evaluation of the impact of CPOE revealed a significant improvement in the provision of useful clinical information from 2005 to 2008, rising from 90.1% (n=749) to 99.8% (n=915) (p<.0001) for wound specimens and 34% (n=129) to 86% (n=422) (p<.0001) for stool specimens. This study showed that the CPOE system provided an integrated platform to access and exchange valuable patient-related information

  9. Analytical difficulties facing today's regulatory laboratories: issues in method validation.

    Science.gov (United States)

    MacNeil, James D

    2012-08-01

    The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.

  10. Laboratory methods to evaluate therapeutic radiopharmaceuticals

    International Nuclear Information System (INIS)

    Arteaga de Murphy, C.; Rodriguez-Cortes, J.; Pedraza-Lopez, M.; Ramirez-Iglesias, MT.; Ferro-Flores, G.

    2007-01-01

    The overall aim of this coordinated research project was to develop in vivo and in vitro laboratory methods to evaluate therapeutic radiopharmaceuticals. Towards this end, the laboratory methods used in this study are described in detail. Two peptides - an 8 amino acid minigastrin analogue and octreotate - were labelled with 177 Lu. Bombesin was labelled with 99 mTc, and its diagnostic utility was proven. For comparison, 99 mTc-TOC was used. The cell lines used in this study were AR42J cells, which overexpress somatostatin receptors found in neuroendocrine cancers, and PC3 cells, which overexpress gastric releasing peptide receptors (GRP-r) found in human prostate and breast cancers. The animal model chosen was athymic mice with implanted dorsal tumours of pathologically confirmed cell cancers. The methodology described for labelling, quality control, and in vitro and in vivo assays can be easily used with other radionuclides and other peptides of interest. (author)

  11. CPT Profiling and Laboratory Data Correlations for Deriving of Selected Geotechnical Parameter

    Directory of Open Access Journals (Sweden)

    Bulko Roman

    2015-12-01

    Full Text Available Currently, can be seen a new trend in engineering geological survey, where laboratory analysis are replaced by in situ testing methods, which are more efficient and cost effective, and time saving too. A regular engineering geological survey cannot be provided by simple core drillings, macroscopic description (sometimes very subjective, and then geotechnical parameters are established based on indicative standardized values or archive values from previous geotechnical standards. The engineering geological survey is trustworthy if is composed of laboratory and in-situ testing supplemented by indirect methods of testing, [1]. The prevalence of rotary core drilling for obtaining laboratory soil samples from various depths (every 1 to 3 m, cannot be a more enhanced as continues evaluation of strata and properties e.g. by CPT Piezocone (every 1 cm. Core drillings survey generally uses small amounts of soil samples, but this is resulting to a lower representation of the subsoil and underestimation of parameters. Higher amounts of soil samples make laboratory testing time-consuming and results from this testing can be influenced by the storage and processing of the soil samples. Preference for geotechnical surveys with in situ testing is therefore a more suitable option. In situ testing using static and dynamic penetration tests can be used as a supplement or as a replacement for the (traditional methods of surveying.

  12. Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

    Science.gov (United States)

    Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta

    2013-05-01

    Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.

  13. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, K.A.; Gray, C.E. (comp.)

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned.

  14. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    International Nuclear Information System (INIS)

    Greulich, K.A.; Gray, C.E.

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned

  15. Health centres' view of the services provided by a university hospital laboratory: Use of satisfaction surveys

    Science.gov (United States)

    Oja, Paula; Kouri, Timo; Pakarinen, Arto

    2010-01-01

    Customer orientation has gained increasing attention in healthcare. A customer satisfaction survey is one way to raise areas and topics for quality improvement. However, it seems that customer satisfaction surveys have not resulted in quality improvement in healthcare. This article reports how the authors' university hospital laboratory has used customer satisfaction surveys targeted at the health centres in their hospital district. Closed-ended statements of the questionnaire were planned to cover the essential aspects of laboratory services. In addition, an open-ended question asked what was considered to be the most important problem in services. The questionnaires were sent to the medical directors of the health centres. The open-ended question proved to be very useful because the responses specified the main problems in service. Based on the responses, selected dissatisfied customers were contacted to specify their responses and possible corrective actions were taken. It is concluded that a satisfaction survey can be used as a screening tool to identify topics of dissatisfaction. In addition, further clarifications with selected customers are needed to specify the causes for their dissatisfaction and to undertake proper corrective actions. PMID:20205616

  16. Quality-assurance plan and field methods for quality-of-water activities, U.S. Geological Survey, Idaho National Engineering Laboratory, Idaho

    International Nuclear Information System (INIS)

    Mann, L.J.

    1996-10-01

    Water-quality activities at the Idaho National Engineering Laboratory (INEL) Project Office are part of the US Geological Survey's (USGS) Water Resources Division (WRD) mission of appraising the quantity and quality of the Nation's water resources. The purpose of the Quality Assurance Plan (QAP) for water-quality activities performed by the INEL Project Office is to maintain and improve the quality of technical products, and to provide a formal standardization, documentation, and review of the activities that lead to these products. The principles of this plan are as follows: (1) water-quality programs will be planned in a competent manner and activities will be monitored for compliance with stated objectives and approaches; (2) field, laboratory, and office activities will be performed in a conscientious and professional manner in accordance with specified WRD practices and procedures by qualified and experienced employees who are well trained and supervised, if or when, WRD practices and procedures are inadequate, data will be collected in a manner that its quality will be documented; (3) all water-quality activities will be reviewed for completeness, reliability, credibility, and conformance to specified standards and guidelines; (4) a record of actions will be kept to document the activity and the assigned responsibility; (5) remedial action will be taken to correct activities that are deficient

  17. Infection control knowledge and practice: A cross-sectional survey on dental laboratories in dental institutes of North India.

    Science.gov (United States)

    Gupta, Sakshi; Rani, Sapna; Garg, Sandeep

    2017-01-01

    The aim of the study was to assess the knowledge of dental laboratory technicians regarding infection control and modes of infection control employed by them. A self-assessment questionnaire-based survey was carried out among dental technicians to assess the knowledge and practice of infection control in dental laboratories. Survey instrument containing 16 questions were randomly distributed to 70 dental colleges of North India regarding knowledge of infection control methods and infection control practised in laboratories. Data were collected and analyzed. The response showed that 30.76% of dental technicians receive 30-50 or more than 50 impressions in a week. About 96.15% of the technicians used a plastic bag to carry impressions. Twenty-five percent of the dental technicians were aware of infection control protocol. Fifty-five percent of the technicians received impressions while wearing gloves and 61.53% of the institutes had a separate receiving area. Nearly 71.15% of the technicians communicate with the doctor regarding the disinfection of impression received in the laboratory. Almost 30.76% of the dental technicians disinfect all the impressions and 67.30% technicians use immersion for disinfection of impressions. Only 38.46% responded that they immerse impressions for 10 min for disinfection. About 73.07% use gloves, 90.38% use mouth masks, 57.69% wear eye shields, and 88.46% wear aprons while working. Nearly 78.84% of the technicians received vaccination against hepatitis B virus. Almost 69.23% of the technicians change pumice slurry after regular intervals, and 75% do not add any disinfectant. Nearly 59.61% of technicians disinfect the prostheses before sending it to the clinic, and 42.30% disinfect them by immersion technique. About disposal of waste, 80.76% said that they dispose the waste properly. To summarize, most of the technicians were not aware of basic infection control protocols.

  18. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  19. Culture methods of allograft musculoskeletal tissue samples in Australian bacteriology laboratories.

    Science.gov (United States)

    Varettas, Kerry

    2013-12-01

    Samples of allograft musculoskeletal tissue are cultured by bacteriology laboratories to determine the presence of bacteria and fungi. In Australia, this testing is performed by 6 TGA-licensed clinical bacteriology laboratories with samples received from 10 tissue banks. Culture methods of swab and tissue samples employ a combination of solid agar and/or broth media to enhance micro-organism growth and maximise recovery. All six Australian laboratories receive Amies transport swabs and, except for one laboratory, a corresponding biopsy sample for testing. Three of the 6 laboratories culture at least one allograft sample directly onto solid agar. Only one laboratory did not use a broth culture for any sample received. An international literature review found that a similar combination of musculoskeletal tissue samples were cultured onto solid agar and/or broth media. Although variations of allograft musculoskeletal tissue samples, culture media and methods are used in Australian and international bacteriology laboratories, validation studies and method evaluations have challenged and supported their use in recovering fungi and aerobic and anaerobic bacteria.

  20. A Survey of Established Veterinary Clinical Skills Laboratories from Europe and North America: Present Practices and Recent Developments.

    Science.gov (United States)

    Dilly, Marc; Read, Emma K; Baillie, Sarah

    Developing competence in clinical skills is important if graduates are to provide entry-level care, but it is dependent on having had sufficient hands-on practice. Clinical skills laboratories provide opportunities for students to learn on simulators and models in a safe environment and to supplement training with animals. Interest in facilities for developing veterinary clinical skills has increased in recent years as many veterinary colleges face challenges in training their students with traditional methods alone. For the present study, we designed a survey to gather information from established veterinary clinical skills laboratories with the aim of assisting others considering opening or expanding their own facility. Data were collated from 16 veterinary colleges in North America and Europe about the uses of their laboratory, the building and associated facilities, and the staffing, budgets, equipment, and supporting learning resources. The findings indicated that having a dedicated veterinary clinical skills laboratory is a relatively new initiative and that colleges have adopted a range of approaches to implementing and running the laboratory, teaching, and assessments. Major strengths were the motivation and positive characteristics of the staff involved, providing open access and supporting self-directed learning. However, respondents widely recognized the increasing demands placed on the facility to provide more space, equipment, and staff. There is no doubt that veterinary clinical skills laboratories are on the increase and provide opportunities to enhance student learning, complement traditional training, and benefit animal welfare.

  1. Results from the geological surveys carried out in the Bure laboratory's shafts

    International Nuclear Information System (INIS)

    Rebours, Herve; Righini, Celine

    2010-01-01

    Document available in extended abstract form only. After the government's authorization to build and operate an underground laboratory, Andra started the investigation works in November 99 on the Meuse/Haute-Marne URL site. The Meuse/Haute-Marne URL is located at the border of the Champagne-Ardenne and Lorraine regions, on the township of Bure in the Callovo-Oxfordian clay-rich rock. On the URL site, the layer is about 135 m-thick and lies at a depth of 417 m to 552 m. The laboratory consists of two levels of experimental drifts at depths of 445 m and 490 m, respectively, with two vertical shafts crossing the 505 m-thick sedimentary cover of Kimeridgian (about 100 meters of marls and limestones), Oxfordian (about 300 meters of limestones) and Callovo-Oxfordian formations. The construction of the underground installations started in August 2000 with the sinking of the main shaft and was completed on the 27 April 2006 when it linked up with the southern drift of the laboratory. The two access shafts are sunk with a drill and blast method with steps of 2.4 to 3.1 m. A temporary support with grouted bolts and wire mesh is set immediately after the blasting and removal of the muck. The definitive concrete lining is installed about 12 to 20 m behind the face. The excavated diameter of the main shaft where the geological surveys and experiments have been undertaken is of 6 m (5 m after lining). The second shaft (auxiliary shaft for the ventilation of the URL) is sunk in a smaller diameter (5 m). The aims of the geological surveys carried out during the shaft sinking are to describe the vertical and lateral (between the two shafts) variations of the lithology, to confirm the absence of fault and the geometry of the argillaceous rocks formation. These surveys allow to characterize the natural or inducted fracturing by a sedimentary and structural follow-up of the excavation face. This follow-up was carried out every 2.4 to 3.0 meters in the shafts. During the shaft

  2. Methods of the National Nutrition Survey 1999

    OpenAIRE

    Resano-Pérez, Elsa; Méndez-Ramírez, Ignacio; Shamah-Levy, Teresa; Rivera, Juan A; Sepúlveda-Amor, Jaime

    2003-01-01

    OBJECTIVE: To describe the methods and analyses of the 1999 National Nutrition Survey (NNS-99). MATERIAL AND METHODS: The 1999 National Nutrition Survey (NNS-99) is a probabilistic survey with nationwide representativity. The NNS-99 included four regions and urban and rural areas of Mexico. The last sampling units were households, selected through stratified cluster sampling. The study population consisted of children under five years of age, school-age children (6-11 years), and women of chi...

  3. Assessment of biosafety precautions in Khartoum state diagnostic laboratories, Sudan

    OpenAIRE

    Elduma, Adel Hussein

    2012-01-01

    Background This study was conducted to evaluate the biosafety precautions that applied by diagnostic laboratories in Khartoum state, 2009. Methods A total number of 190 laboratories were surveyed about their compliance with standard biosafety precautions. These laboratories included 51 (27%) laboratories from government, 75 (39%) from private sectors and 64 (34%) laboratories belong to organization providing health care services. Results The study found that 32 (16.8%) of laboratories appoint...

  4. Survey and analysis of deep water mineral deposits using nuclear methods

    International Nuclear Information System (INIS)

    Staehle, C.M.; Noakes, J.E.; Spaulding, J.

    1991-01-01

    Present knowledge of the location, quality, quantity and recoverability of sea floor minerals is severely limited, particularly in the abyssal depths and deep water within the 200 mile Exclusion Economic Zone (EEZ) surrounding the U.S. Pacific Islands. To improve this understanding and permit exploitation of these mineral reserves much additional data is needed. This paper will discuss a sponsored program for extending existing proven nuclear survey methods currently used on the shallow continental margins of the Atlantic and Gulf of Mexico into the deeper waters of the Pacific. This nuclear technology can be readily integrated and extended to depths of 2000 m using the existing RCV-150 remotely operated vehicle (ROV) and the PISCESE V manned deep submersible vehicle (DSV) operated by The University of Hawaii's, Hawaii Underseas Research Laboratory (HURL). Previous papers by the authors have also proposed incorporating these nuclear analytical methods for survey of the deep ocean through the use of Autonomous Underwater Vehicle (AUX). Such a vehicle could extend the use of passive nuclear instrument operation, in addition to conventional analytical methods, into the abyssal depths and do so with speed and economy not otherwise possible. The natural radioactivity associated with manganese nodules and crustal deposits is sufficiently above normal background levels to allow discrimination and quantification in near real time

  5. Quality-assurance results for routine water analysis in US Geological Survey laboratories, water year 1991

    Science.gov (United States)

    Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.

    1994-01-01

    The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and

  6. A Survey of Rabbit Handling Methods Within the United Kingdom and the Republic of Ireland.

    Science.gov (United States)

    Oxley, James Andrew; Ellis, Clare Frances; McBride, E Anne; McCormick, Wanda Denise

    2018-04-25

    Rabbits are commonly kept in a variety of settings, including homes, laboratories, and veterinary clinics. Despite the popularity of keeping this prey species, little research has investigated current methods of handling. The aim of this study was to examine the experience of caregivers (owners and keepers) in using five handling methods commonly referred to in books written for companion animal (pet) owners and veterinary and/or laboratory personnel. An online survey was completed by 2644 respondents, representing all three of these groups, and breeders. Data were acquired to determine sources that participants used to gain knowledge of different handling methods, the methods they used and for what purposes they used them, and their perceptions of any associated difficulties or welfare concerns. Results indicated that participants most frequently used the method of supporting a rabbit's body against a person's chest, which was considered the easiest and most welfare-friendly method of the handling methods explored. "Scruffing with rear support" was the least used method and was considered to be distressing and painful for the rabbit. As rabbits are a terrestrial prey species, being picked up is likely an innately stressful experience. Additional research is encouraged to explore the experience of rabbits during handling to identify methods that can be easily used with the fewest welfare compromises.

  7. Research Methods in Healthcare Epidemiology: Survey and Qualitative Research.

    Science.gov (United States)

    Safdar, Nasia; Abbo, Lilian M; Knobloch, Mary Jo; Seo, Susan K

    2016-11-01

    Surveys are one of the most frequently employed study designs in healthcare epidemiology research. Generally easier to undertake and less costly than many other study designs, surveys can be invaluable to gain insights into opinions and practices in large samples and may be descriptive and/or be used to test associations. In this context, qualitative research methods may complement this study design either at the survey development phase and/or at the interpretation/extension of results stage. This methods article focuses on key considerations for designing and deploying surveys in healthcare epidemiology and antibiotic stewardship, including identification of whether or not de novo survey development is necessary, ways to optimally lay out and display a survey, denominator measurement, discussion of biases to keep in mind particularly in research using surveys, and the role of qualitative research methods to complement surveys. We review examples of surveys in healthcare epidemiology and antimicrobial stewardship and review the pros and cons of methods used. A checklist is provided to help aid design and deployment of surveys in healthcare epidemiology and antimicrobial stewardship. Infect Control Hosp Epidemiol 2016;1-6.

  8. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  9. A Laboratory for studying radon mitigation methods in high-rise office buildings in Hong Kong

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Hung, L.C.; Tso, M.Y.W.

    1996-01-01

    A territory-wide survey of indoor radon level in 1993 showed that 17% of offices Hong Kong have radon concentrations above 200 Bq m -3 compared with 4% for dwellings. Consequently, the Radioisotope Unit Radon Analysis Laboratory (RURAL) is being built for studying radon mitigation methods applicable to high-rise office buildings. The laboratory consists of three rooms; the main exposure room is built of concrete and is surrounded by the buffer room; and all controls and operations are done inside the control room. The exposure room can, with the aid of the buffer room, simulate any environmental conditions that can be faced by a real building. The pressure, temperature and humidity can be adjusted to any meteorological conditions that can be found in Hong Kong. Pressure differential and temperature differential can be adjusted to simulate the arrival of fronts, troughs or typhoons. Aerosol concentration and distribution inside the exposure room are controllable as well as the ventilation conditions. Various mitigation methods will be tested under different conditions. Passive methods include application of radon barriers to building structures and active methods include the use of air cleaners; techniques to increase radon daughters plateout or reduce their attachment to aerosols; and various modifications to the ventilation systems. Mitigation techniques involving modifications to the building strictures and building services will also be developed with the help of the RURAL. (author)

  10. AERIAL RADIOLOGICAL SURVEYS

    International Nuclear Information System (INIS)

    Proctor, A.E.

    1997-01-01

    Measuring terrestrial gamma radiation from airborne platforms has proved to be a useful method for characterizing radiation levels over large areas. Over 300 aerial radiological surveys have been carried out over the past 25 years including U.S. Department of Energy (DOE) sites, commercial nuclear power plants, Formerly Utilized Sites Remedial Action Program/Uranium Mine Tailing Remedial Action Program (FUSRAP/UMTRAP) sites, nuclear weapons test sites, contaminated industrial areas, and nuclear accident sites. This paper describes the aerial measurement technology currently in use by the Remote Sensing Laboratory (RSL) for routine environmental surveys and emergency response activities. Equipment, data-collection and -analysis methods, and examples of survey results are described

  11. Comparison of the analysis result between two laboratories using different methods

    International Nuclear Information System (INIS)

    Sri Murniasih; Agus Taftazani

    2017-01-01

    Comparison of the analysis result of volcano ash sample between two laboratories using different analysis methods. The research aims to improve the testing laboratory quality and cooperate with the testing laboratory from other country. Samples were tested at the Center for Accelerator of Science and Technology (CAST)-NAA laboratory using NAA, while at the University of Texas (UT) USA using ICP-MS and ENAA method. From 12 elements of target, CAST-NAA able to present 11 elements of data analysis. The comparison results shows that the analysis of the K, Mn, Ti and Fe elements from both laboratories have a very good comparison and close one to other. It is known from RSD values and correlation coefficients of the both laboratories analysis results. While observed of the results difference known that the analysis results of Al, Na, K, Fe, V, Mn, Ti, Cr and As elements from both laboratories is not significantly different. From 11 elements were reported, only Zn which have significantly different values for both laboratories. (author)

  12. Environmental Survey preliminary report, Idaho National Engineering Laboratory, Idaho Falls, Idaho and Component Development and Integration Facility, Butte, Montana

    International Nuclear Information System (INIS)

    1988-09-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations' carried on at the INEL and the CDIF, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S ampersand A) Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The S ampersand A Plan will be executed by the Oak Ridge National Laboratory. When completed, the S ampersand A results will be incorporated into the INEL/CDIF Survey findings for inclusion into the Environmental Survey Summary Report. 90 refs., 95 figs., 77 tabs

  13. Environmental Survey preliminary report, Idaho National Engineering Laboratory, Idaho Falls, Idaho and Component Development and Integration Facility, Butte, Montana

    Energy Technology Data Exchange (ETDEWEB)

    1988-09-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations' carried on at the INEL and the CDIF, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S A) Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The S A Plan will be executed by the Oak Ridge National Laboratory. When completed, the S A results will be incorporated into the INEL/CDIF Survey findings for inclusion into the Environmental Survey Summary Report. 90 refs., 95 figs., 77 tabs.

  14. Survey Methods, Traditional, Public Opinion Polling

    DEFF Research Database (Denmark)

    Elmelund-Præstekær, Christian; Hopmann, David Nicolas; Pedersen, Rasmus Tue

    2017-01-01

    Traditional public opinion polls are surveys in which a random sample of a given population is asked questions about their attitudes, knowledge, or behavior. If conducted properly, the answers from such surveys are approximately representative of the entire population. Traditional public opinion...... polling is typically based on four different methods of data gathering, or combinations hereof: face-to-face, postal surveys, phone surveys, and web surveys. Given that opinion polls are based on a sample, we cannot be sure that the sample reflects public opinion perfectly, however—even if randomness...... is perfect. Moreover, responses may be highly dependent on the contextual information provided with the question. Also, it may be difficult to capture past or complex causes of attitudes or behavior. In short, surveys are a precise way of measuring public opinion, but they do not come without challenges....

  15. Quality-Assurance Plan for the Analysis of Fluvial Sediment by the U. S. Geological Survey Kentucky Water Science Center Sediment Laboratory

    National Research Council Canada - National Science Library

    Shreve, Elizabeth A; Downs, Aimee C

    2005-01-01

    This report describes laboratory procedures used by the U. S. Geological Survey Kentucky Water Science Center Sediment Laboratory for the processing and analysis of fluvial sediment samples for concentration of sand and finer material...

  16. Cost comparison of laboratory methods and four field screening technologies for uranium-contaminated soil

    International Nuclear Information System (INIS)

    Douthat, D.M.; Armstrong, A.Q.

    1994-01-01

    To address the problem of characterizing uranium-contaminated surface soil at federal facilities, the Department of Energy has the development of four uranium field screening technologies, under the direction of the Uranium-in-Soils Integrated Demonstration (USID) Program. These four technologies include: a long-range alpha detector a beta scintillation detector, an in situ gamma detector, and a mobile laser ablation-inductively coupled plasma/atomic emission spectrometry (LA-ICP/AES) laboratory. As part of the performance assessment for these field screening technologies, cost estimates for the development and operation of each technology were created. A cost study was conducted to compare three of the USID field screening technologies to the use of traditional field surveying equipment to adequately characterize surface soils of a one-acre site. The results indicate that the use of traditional equipment costs more than the in situ gamma detector, but less than the beta scintillation detector and LRAD. The use of traditional field surveying equipment results in cost savings of 4% and 34% over the use of the beta scintillation and LRAD technologies, respectively. A study of single-point surface soil sampling and laboratory analysis costs was also conducted. Operational costs of the mobile LA-ICP/AES laboratory were compared with operational costs of traditional sampling and analysis, which consists of collecting soil samples and conducting analysis in a radiochemical laboratory. The cost study indicates that the use of the mobile LA-ICP/AES laboratory results in cost savings of 23% and 40% over traditional field sampling and laboratory analysis conducted by characterization groups at two DOE facilities

  17. Quality control for diagnostic oral microbiology laboratories in European countries

    Directory of Open Access Journals (Sweden)

    Andrew J. Smith

    2011-11-01

    Full Text Available Participation in diagnostic microbiology internal and external quality control (QC processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into the study and six laboratories from six European countries completed both the online survey and the first QC round. Three additional laboratories participated in the second round. Based on the survey, European oral microbiology laboratories process a significant (mean per laboratory 4,135 number of diagnostic samples from the oral cavity annually. A majority of the laboratories did not participate in any internal or external QC programme and nearly half of the laboratories did not have standard operating procedures for the tests they performed. In both QC rounds, there was a large variation in the results, interpretation and reporting of antibiotic susceptibility testing among the laboratories. In conclusion, the results of this study demonstrate the need for harmonisation of laboratory processing methods and interpretation of results for oral microbiology specimens. The QC rounds highlighted the value of external QC in evaluating the efficacy and safety of processes, materials and methods used in the laboratory. The use of standardised methods is also a prerequisite for multi-centre epidemiological studies that can provide important information on emerging microbes and trends in anti-microbial susceptibility for empirical prescribing in oro-facial infections.

  18. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  19. METHODS IN THE POST-METHODS ERA. REPORT ON AN INTERNATIONAL SURVEY ON LANGUAGE TEACHING METHODS'

    Directory of Open Access Journals (Sweden)

    Jun Liu

    2004-06-01

    Full Text Available Do methods still have a place in 21" century language teaching? To answer this question, an international survey was conducted in the surnmer of 1999. A sample of 800 language teachers world-wide randomly drawn from 17,800 TESOLers were each given a 2-page survey. The return rate was 58.5% with the actual usable data set of448, which was analyzed by using both descriptive and inferential statistics. Among the ten commonly recognized teaching methods surveyed, both the Communicative Language Teaching Approach and an eclectic method seem to have the highest rate in familiarity, preference, and use. But when multiple factors, such as teaching contexts, instructional settings, learners' proficiency levels, class size, teaching experience and educational backgrounds of the teachers, and the status of being a native or nonnative English speaking professional were taken into consideration, various patterns and themes emerged. One interesting finding is that Grammar Translation is still used in EFL contexts, in larger classes, and with learners at low proficiency levels, though the ratio between the actual use of this method and teachers' preference does not match. Based on the results of the survey, a new theoretical framework is proposed to conceptualize language teaching methods in the post-methods era.

  20. DO TIE LABORATORY BASED METHODS REALLY REFLECT FIELD CONDITIONS

    Science.gov (United States)

    Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both interstitial waters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question ...

  1. Analysis of laboratory compaction methods of roller compacted concrete

    Science.gov (United States)

    Trtík, Tomáš; Chylík, Roman; Bílý, Petr; Fládr, Josef

    2017-09-01

    Roller-Compacted Concrete (RCC) is an ordinary concrete poured and compacted with machines typically used for laying of asphalt road layers. One of the problems connected with this technology is preparation of representative samples in the laboratory. The aim of this work was to analyse two methods of preparation of RCC laboratory samples with bulk density as the comparative parameter. The first method used dynamic compaction by pneumatic hammer. The second method of compaction had a static character. The specimens were loaded by precisely defined force in laboratory loading machine to create the same conditions as during static rolling (in the Czech Republic, only static rolling is commonly used). Bulk densities obtained by the two compaction methods were compared with core drills extracted from real RCC structure. The results have shown that the samples produced by pneumatic hammer tend to overestimate the bulk density of the material. For both compaction methods, immediate bearing index test was performed to verify the quality of compaction. A fundamental difference between static and dynamic compaction was identified. In static compaction, initial resistance to penetration of the mandrel was higher, after exceeding certain limit the resistance was constant. This means that the samples were well compacted just on the surface. Specimens made by pneumatic hammer actively resisted throughout the test, the whole volume was uniformly compacted.

  2. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    International Nuclear Information System (INIS)

    Gauglitz, Erica; Nagatomy, Helio Rissei; Moura, Eduardo S.; Zeituni, Carlos Alberto; Hilario, Katia A. Fonseca; Rostelato, Maria Elisa C.M.; Karam Junior, Dib

    2009-01-01

    This paper presents the survey of parameters for the installation and implementation of a laboratory for radioactive sources production at immobilized resin. These sources are used in nuclear medicine for verification of dose calibrators, as the standard guidelines of the National Commission of Nuclear CNEN-NE-3.05 'Radioprotection and safety requirements for nuclear medicine services.' The radioisotopes used for this purpose are: Co-57, Cs-137 and Ba-133, with activities of 185 MBq, 9.3 MBq and 5.4 MBq, respectively. The parameters for the assembly of the laboratory shall be defined according to guidelines that guide the deployment of radiochemical laboratories and standards of the National Commission of Nuclear Energy. (author)

  3. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, Erica; Nagatomy, Helio Rissei; Moura, Eduardo S.; Zeituni, Carlos Alberto; Hilario, Katia A. Fonseca; Rostelato, Maria Elisa C.M., E-mail: egauglitz@ipen.b, E-mail: elisaros@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam Junior, Dib, E-mail: dib.karan@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    This paper presents the survey of parameters for the installation and implementation of a laboratory for radioactive sources production at immobilized resin. These sources are used in nuclear medicine for verification of dose calibrators, as the standard guidelines of the National Commission of Nuclear CNEN-NE-3.05 'Radioprotection and safety requirements for nuclear medicine services.' The radioisotopes used for this purpose are: Co-57, Cs-137 and Ba-133, with activities of 185 MBq, 9.3 MBq and 5.4 MBq, respectively. The parameters for the assembly of the laboratory shall be defined according to guidelines that guide the deployment of radiochemical laboratories and standards of the National Commission of Nuclear Energy. (author)

  4. A comparison of two microscale laboratory reporting methods in a secondary chemistry classroom

    Science.gov (United States)

    Martinez, Lance Michael

    This study attempted to determine if there was a difference between the laboratory achievement of students who used a modified reporting method and those who used traditional laboratory reporting. The study also determined the relationships between laboratory performance scores and the independent variables score on the Group Assessment of Logical Thinking (GALT) test, chronological age in months, gender, and ethnicity for each of the treatment groups. The study was conducted using 113 high school students who were enrolled in first-year general chemistry classes at Pueblo South High School in Colorado. The research design used was the quasi-experimental Nonequivalent Control Group Design. The statistical treatment consisted of the Multiple Regression Analysis and the Analysis of Covariance. Based on the GALT, students in the two groups were generally in the concrete and transitional stages of the Piagetian cognitive levels. The findings of the study revealed that the traditional and the modified methods of laboratory reporting did not have any effect on the laboratory performance outcome of the subjects. However, the students who used the traditional method of reporting showed a higher laboratory performance score when evaluation was conducted using the New Standards rubric recommended by the state. Multiple Regression Analysis revealed that there was a significant relationship between the criterion variable student laboratory performance outcome of individuals who employed traditional laboratory reporting methods and the composite set of predictor variables. On the contrary, there was no significant relationship between the criterion variable student laboratory performance outcome of individuals who employed modified laboratory reporting methods and the composite set of predictor variables.

  5. The use of error and uncertainty methods in the medical laboratory.

    Science.gov (United States)

    Oosterhuis, Wytze P; Bayat, Hassan; Armbruster, David; Coskun, Abdurrahman; Freeman, Kathleen P; Kallner, Anders; Koch, David; Mackenzie, Finlay; Migliarino, Gabriel; Orth, Matthias; Sandberg, Sverre; Sylte, Marit S; Westgard, Sten; Theodorsson, Elvar

    2018-01-26

    Error methods - compared with uncertainty methods - offer simpler, more intuitive and practical procedures for calculating measurement uncertainty and conducting quality assurance in laboratory medicine. However, uncertainty methods are preferred in other fields of science as reflected by the guide to the expression of uncertainty in measurement. When laboratory results are used for supporting medical diagnoses, the total uncertainty consists only partially of analytical variation. Biological variation, pre- and postanalytical variation all need to be included. Furthermore, all components of the measuring procedure need to be taken into account. Performance specifications for diagnostic tests should include the diagnostic uncertainty of the entire testing process. Uncertainty methods may be particularly useful for this purpose but have yet to show their strength in laboratory medicine. The purpose of this paper is to elucidate the pros and cons of error and uncertainty methods as groundwork for future consensus on their use in practical performance specifications. Error and uncertainty methods are complementary when evaluating measurement data.

  6. Processing of fallopian tube, ovary, and endometrial surgical pathology specimens: A survey of U.S. laboratory practices.

    Science.gov (United States)

    Samimi, Goli; Trabert, Britton; Duggan, Máire A; Robinson, Jennifer L; Coa, Kisha I; Waibel, Elizabeth; Garcia, Edna; Minasian, Lori M; Sherman, Mark E

    2018-03-01

    Many high-grade serous carcinomas initiate in fallopian tubes as serous tubal intraepithelial carcinoma (STIC), a microscopic lesion identified with specimen processing according to the Sectioning and Extensive Examination of the Fimbria protocol (SEE-Fim). Given that the tubal origin of these cancers was recently recognized, we conducted a survey of pathology practices to assess processing protocols that are applied to gynecologic surgical pathology specimens in clinical contexts in which finding STIC might have different implications. We distributed a survey electronically to the American Society for Clinical Pathology list-serve to determine practice patterns and compared results between practice types by chi-square (χ2) tests for categorical variables. Free text comments were qualitatively reviewed. Survey responses were received from 159 laboratories (72 academic, 87 non-academic), which reported diverse specimen volumes and percentage of gynecologic samples. Overall, 74.1% of laboratories reported performing SEE-Fim for risk-reducing surgical specimens (82.5% academic versus 65.7% non-academic, p STIC or early cancer precursors. Published by Elsevier Inc.

  7. Access to scientific information. A national survey of the Italian Society of Clinical Biochemistry and Laboratory Medicine (SIBioC).

    Science.gov (United States)

    Lippi, Giuseppe; Ciaccio, Marcello; Giavarina, Davide

    2016-09-01

    Digital libraries are typically used for retrieving and accessing articles in academic journals and repositories. Previous studies have been published about the performance of various biomedical research platforms, but no information is available about access preferences. A six-question survey was designed by the Italian Society of Clinical Biochemistry and Laboratory Medicine (SIBioC) using the platform Google Drive, and made available for 1 month to the members of the society. The information about the survey was published on the website of SIBioC and also disseminated by two sequential newsletters. Overall, 165 replies were collected throughout the 1-month survey availability. The largest number of replies were provided by laboratory professionals working in the national healthcare system (44.2%), followed by those working in private facilities (13.9%), university professors (12.7%) and specialization training staff (12.7%). The majority of responders published zero to one articles per year (55.2%), followed by two to five articles per year (37.6%), whereas only 7.3% published more than five articles per year. A total of 34.5% of the responders consulted biomedical research platforms on weekly basis, followed by 33.9% who did so on daily basis. PubMed/Medline was the most accessed scientific database, followed by Scopus, ISI Web of Science and Google Scholar. The impact factor was the leading reason when selecting which journal to publish in. The most consulted journals in the field of laboratory medicine were Clinical Chemistry and Laboratory Medicine and Biochimica Clinica. This survey provides useful indications about the personal inclination towards access to scientific information in our country.

  8. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    Science.gov (United States)

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  9. Diagnostic trends in Clostridium difficile detection in Finnish microbiology laboratories.

    Science.gov (United States)

    Könönen, Eija; Rasinperä, Marja; Virolainen, Anni; Mentula, Silja; Lyytikäinen, Outi

    2009-12-01

    Due to increased interest directed to Clostridium difficile-associated infections, a questionnaire survey of laboratory diagnostics of toxin-producing C. difficile was conducted in Finland in June 2006. Different aspects pertaining to C. difficile diagnosis, such as requests and criteria used for testing, methods used for its detection, yearly changes in diagnostics since 1996, and the total number of investigations positive for C. difficile in 2005, were asked in the questionnaire, which was sent to 32 clinical microbiology laboratories, including all hospital-affiliated and the relevant private clinical microbiology laboratories in Finland. The situation was updated by phone and email correspondence in September 2008. In June 2006, 28 (88%) laboratories responded to the questionnaire survey; 24 of them reported routinely testing requested stool specimens for C. difficile. Main laboratory methods included toxin detection (21/24; 88%) and/or anaerobic culture (19/24; 79%). In June 2006, 18 (86%) of the 21 laboratories detecting toxins directly from feces, from the isolate, or both used methods for both toxin A (TcdA) and B (TcdB), whereas only one laboratory did so in 1996. By September 2008, all of the 23 laboratories performing diagnostics for C. difficile used methods for both TcdA and TcdB. In 2006, the number of specimens processed per 100,000 population varied remarkably between different hospital districts. In conclusion, culturing C. difficile is common and there has been a favorable shift in toxin detection practice in Finnish clinical microbiology laboratories. However, the variability in diagnostic activity reported in 2006 creates a challenge for national monitoring of the epidemiology of C. difficile and related diseases.

  10. Field Methods and Quality-Assurance Plan for Quality-of-Water Activities, U.S. Geological Survey, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Knobel, LeRoy L.; Tucker, Betty J.; Rousseau, Joseph P.

    2008-01-01

    Water-quality activities conducted by the staff of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation's water resources. The activities are conducted in cooperation with the U.S. Department of Energy's (DOE) Idaho Operations Office. Results of the water-quality investigations are presented in various USGS publications or in refereed scientific journals. The results of the studies are highly regarded, and they are used with confidence by researchers, regulatory and managerial agencies, and interested civic groups. In its broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the 'state-of-the-art' technology, and quality assurance ensures that quality control is maintained within specified limits.

  11. Environmental Survey preliminary report, Department of Energy (DOE) activities at Santa Susana Field Laboratories, Ventura County, California

    Energy Technology Data Exchange (ETDEWEB)

    1989-02-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) activities at the Santa Susana Field Laboratories Site (DOE/SSFL), conducted May 16 through 26, 1988. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual participants for the Survey team are being supplied by an private contractor. The objective of the survey is to identify environmental problems and areas of environmental risk associated with DOE activities at SSFL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations performed at SSFL, and interviews with site personnel. 90 refs., 17 figs., 28 tabs.

  12. Moving beyond Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…

  13. Aerial radiological survey of the Brookhaven National Laboratory and surrounding area, Upton, New York. Date of survey: June 1983

    International Nuclear Information System (INIS)

    Hobaugh, J.L.

    1985-02-01

    An aerial radiological survey was performed from 11 to 13 June 1983, over approximately a 64-square-kilometer (25-square-mile) area surrounding the Brookhaven National Laboratory (BNL). BNL is located in the center of Suffolk County, Long Island, New York. All gamma radiation data were collected by flying east-west lines spaced 76 meters (250 feet) apart at an altitude of 46 meters (150 feet) above ground level. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground. The average background exposure rate in the survey area ranged from 5 to 10 microroentgens per hour (μR/h). The reported exposure rate values include an estimated cosmic ray contribution of 4.0 μR/h. Ground-based measurements made during the same time period were compared to the aerial survey results. Pressurized ion chamber readings and soil samples were taken from two locations within the aerial survey boundaries. Exposure rate values obtained from these measurement techniques were in agreement with those obtained from the aerial data. A total of 23 areas of man-made radioactivity were identified. The dominant isotopes found over these areas were cesium-137, sodium-22, manganese-54, and cobalt-60. A similar survey was conducted in May 1980. The 1983 survey results were similar to the 1980 results. Three areas of low level man-made activity were not reproduced by the 1983 data. Ten new areas were detected. The major difference occurred because of the increased sensitivity and spatial reduction brought on by lowering the altitude and decreasing the line spacing. 8 refs., 28 figs., 4 tabs

  14. Laboratory methods for determining pneumonia etiology in children

    NARCIS (Netherlands)

    Murdoch, David R.; O'Brien, Katherine L.; Driscoll, Amanda J.; Karron, Ruth A.; Bhat, Niranjan; Black, Robert E.; Bhutta, Zulfiqar A.; Campbell, Harry; Cherian, Thomas; Crook, Derrick W.; de Jong, Menno D.; Dowell, Scott F.; Graham, Stephen M.; Klugman, Keith P.; Lanata, Claudio F.; Madhi, Shabir A.; Martin, Paul; Nataro, James P.; Piazza, Franco M.; Qazi, Shamim A.; Zar, Heather J.; Levine, Orin S.; Knoll, Maria Deloria; Feikin, Daniel R.; Scott, J. Anthony G.; Driscoll, Amanda; DeLuca, Andrea; Crawley, Jane

    2012-01-01

    Laboratory diagnostics are a core component of any pneumonia etiology study. Recent advances in diagnostic technology have introduced newer methods that have greatly improved the ability to identify respiratory pathogens. However, determining the microbial etiology of pneumonia remains a challenge,

  15. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    Science.gov (United States)

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  16. Special case waste located at Oak Ridge National Laboratory facilities: Survey report

    International Nuclear Information System (INIS)

    Forgy, J.R. Jr.

    1995-11-01

    Between October 1994 and October 1995, a data base was established at the Oak Ridge National Laboratory (ORNL) to provide a current inventory of the radioactive waste materials, located at ORNL, for which the US Department of Energy (DOE) has no definite planned disposal alternatives. DOE refers to these waste materials as special case waste. To assist ORNL and DOE management in future planning, an inventory system was established and a baseline inventory prepared. This report provides the background of the ORNL special case waste survey project, as well as special case waste category definitions, both current and anticipated sources and locations of special case waste materials, and the survey and data management processes. Special case waste will be that waste material which, no matter how much practical characterization, treatment, and packaging is made, will never meet the acceptance criteria for permanent disposal at ORNL, and does not meet the criteria at a currently planned off-site permanent disposal facility

  17. Data survey about radiation protection and safety of radiation sources in research laboratories

    International Nuclear Information System (INIS)

    Paura, Clayton L.; Dantas, Ana Leticia A.; Dantas, Bernardo M.

    2005-01-01

    In Brazil, different types of research using unsealed sources are developed with a variety of radioisotopes. In such activities, professionals and students involved are potentially exposed to internal contamination by 14 C, 45 Ca, 51 Cr, 3 H, 125 I, 32 P, 33 P, 35 S, 90 Sr and 99m Tc. The general objective of this work is to evaluate radiological risks associated to these practices in order to supply information for planning actions aimed to improve radiation protection conditions in research laboratories. The criteria for risk evaluation and the safety aspects adopted in this work were based on CNEN Regulation 6.02 and in IAEA and NRPB publications. The survey of data was carried out during visits to laboratories in public Universities located in the city of Rio de Janeiro where unsealed radioactive sources are used in biochemistry, biophysics and genetic studies. According to the criteria adopted in this work, some practices developed in the laboratories require evaluation of risk of internal contamination depending on the conditions of source manipulation. It was verified the need for training of users of radioactive materials in this type of laboratory. This can be facilitated by the use of basic guides for the classification of areas, radiation protection, safety and source security in research laboratories. It was also observed the need for optimization of such practices in order to minimize the contact with sources. It is recommended to implement more effective source and access controls as a way to reduce risks of individual radiation exposure and loss of radioactive materials (author)

  18. Comparison of a New Cobinamide-Based Method to a Standard Laboratory Method for Measuring Cyanide in Human Blood

    Science.gov (United States)

    Swezey, Robert; Shinn, Walter; Green, Carol; Drover, David R.; Hammer, Gregory B.; Schulman, Scott R.; Zajicek, Anne; Jett, David A.; Boss, Gerry R.

    2013-01-01

    Most hospital laboratories do not measure blood cyanide concentrations, and samples must be sent to reference laboratories. A simple method is needed for measuring cyanide in hospitals. The authors previously developed a method to quantify cyanide based on the high binding affinity of the vitamin B12 analog, cobinamide, for cyanide and a major spectral change observed for cyanide-bound cobinamide. This method is now validated in human blood, and the findings include a mean inter-assay accuracy of 99.1%, precision of 8.75% and a lower limit of quantification of 3.27 µM cyanide. The method was applied to blood samples from children treated with sodium nitroprusside and it yielded measurable results in 88 of 172 samples (51%), whereas the reference laboratory yielded results in only 19 samples (11%). In all 19 samples, the cobinamide-based method also yielded measurable results. The two methods showed reasonable agreement when analyzed by linear regression, but not when analyzed by a standard error of the estimate or paired t-test. Differences in results between the two methods may be because samples were assayed at different times on different sample types. The cobinamide-based method is applicable to human blood, and can be used in hospital laboratories and emergency rooms. PMID:23653045

  19. Sampling methods. A survey of methods in use in the Nordic countries

    International Nuclear Information System (INIS)

    Isaksson, M.

    2000-10-01

    This report is a survey of sampling techniques currently in use for radioactivity measurements in the Nordic countries, but restricted to sampling techniques for pasture, soil and deposition in emergency situations. It is found that the participating laboratories apply similar sampling procedures for pasture, including cutting height and size of sampled areas. Soil samples are generally taken by some sort of corer of different diameter. The number of cores taken varies, different sampling patterns are used, and pooling of the samples is done by some of the laboratories. The analysis of pasture and of soil is made with Nal-detectors or by high-resolution gamma spectrometry on fresh or dried samples. Precipitation collectors of a range of sizes are used to determine the activity concentration in precipitation and of dry deposited radionuclides. The analysis is made with high-resolution gamma-spectrometry, either directly on a water sample or on ion exchange resins. (au)

  20. An aerial radiological survey of the Superconducting Super Collider Laboratory and surrounding area, Waxahachie, Texas

    International Nuclear Information System (INIS)

    Fritzsche, A.E.

    1993-02-01

    An aerial radiological survey was conducted over the Superconducting Super Collider Laboratory (SSCL) site from July 22 through August 20,1991. Parallel lines were flown at intervals of 305 meters over a 1,036-square-kilometer (400-square-mile) area surrounding Waxahachie, Texas. The 70,000 terrestrial gamma energy spectra obtained were reduced to an exposure rate contour map overlaid on a United States Geological Survey (USGS) map of the area. The mean terrestrial exposure rate measured was 5.4 μR/h at 1 meter above ground level. Comparison to ground-based measurements shows good agreement. No anomalous or man-made isotopes were detected

  1. Survey Research: Methods, Issues and the Future

    Science.gov (United States)

    Brewer, Ernest W.; Torrisi-Steele, Geraldine; Wang, Victor C. X.

    2015-01-01

    Survey research is prevalent among many professional fields. Both cost effective and time efficient, this method of research is commonly used for the purposes of gaining insight into the attitudes, thoughts, and opinions of populations. Additionally, because there are several types of survey research designs and data collection instruments, the…

  2. Laboratory 3.0: Manufacturing technologies laboratory virtualization with a student-centred methodology

    Directory of Open Access Journals (Sweden)

    Albert Fabregat-Sanjuan

    2017-06-01

    Full Text Available This paper presents a blended-learning strategy for improving the teaching method applied in the laboratory subject Manufacturing Technologies. The teaching method has been changed from a predominantly teacher-centred to an active learning system with a student-centred focus and e-learning activities. In face-to-face classes, a game-based learning platform has been used. This methodology ensured engaging classes at the same time that provided a useful live feedback for students and teachers. The virtualization of the laboratory was achieved by two different e-learning activities, self-assessment tasks and video clips. These e-learning tools have been used not only to improve the students’ learning but also to enhance their motivation. The results from academic outputs show a significant improvement after the new blended learning method is applied. Moreover, a student satisfaction survey shows the positive impact of the methodology on the students’ engagement and motivation.

  3. [How do hospital clinical laboratories and laboratory testing companies cooperate and build reciprocal relations?].

    Science.gov (United States)

    Kawano, Seiji

    2014-12-01

    As the 2nd Joint Symposium of the Japanese Society of Laboratory Medicine and the Japanese Association of Laboratory Pathologists, the symposium on clinical test out-sourcing and branch laboratories was held at the 60th General Meeting of the Japanese Society of Laboratory Medicine on November 2nd, 2013 in Kobe. For the symposium, we conducted a questionnaire survey on the usage of clinical test out-sourcing and the introduction of branch laboratories to clinical laboratories of Japanese university hospitals, both private and public, between July 25th and August 20th, 2013. Seventy-two hospitals responded to the questionnaire survey, consisting of 41 public medical school hospitals and 31 private ones. According to the survey, the selection of each clinical test for out-sourcing was mainly determined by the capacities of hospital clinical laboratories and their equipment, as well as the profitability of each test. The main concerns of clinical laboratory members of university hospitals involved the continuity of measurement principles, traceability, and standardization of reference values for each test. They strongly requested the interchangeability and computerization of test data between laboratory testing companies. A branch laboratory was introduced to six hospitals, all of which were private medical college hospitals, out of 72 university hospitals, and eight of the other hospitals were open to its introduction. The merits and demerits of introducing a branch laboratory were also discussed. (Review).

  4. Survey of laboratory findings in suspected cases of bovine spongiform encephalopathy in Denmark from 1990 to 2000

    DEFF Research Database (Denmark)

    Agerholm, J.S.; Tegtmeier, C.L.; Nielsen, T.K.

    2002-01-01

    A survey of the laboratory findings in suspected cases of bovine spongiform encephalopathy (BSE) in Denmark from I June 1990 to '31 December 2000 is presented. During this period BSE was a notifiable disease, and the heads of suspected cases were submitted according to the legislation on BSE....... A total of 176 submissions were made, mostly from bovines with neurological disorders and mainly during the last 3 years of this period. Lesions or other laboratory findings consistent with severe neurological disorders were found in 115 cases. The most frequent diagnosis was encephalic 41 p listeriosis...

  5. DNA decontamination methods for internal quality management in clinical PCR laboratories.

    Science.gov (United States)

    Wu, Yingping; Wu, Jianyong; Zhang, Zhihui; Cheng, Chen

    2018-03-01

    The polymerase chain reaction (PCR) technique, one of the most commonly applied methods in diagnostic and molecular biology, has a frustrating downside: the occurrence of false-positive signals due to contamination. In previous research, various DNA decontamination methods have been developed to overcome this limitation. Unfortunately, the use of random or poorly focused sampling methods for monitoring air and/or object surfaces leads to the incomplete elimination during decontamination procedures. We herein attempted to develop a novel DNA decontamination method (environmental surveillance, including surface and air sampling) and quality management program for clinical molecular diagnostic laboratories (or clinical PCR laboratories). Here, we performed a step-by-step evaluation of current DNA decontamination methods and developed an effective procedure for assessing the presence of decontaminating DNA via PCR analysis. Performing targeted environmental surveillance by sampling, which reached optimal performance over 2 weeks, and the decontamination process had been verified as reliable. Additionally, the process was validated to not affect PCR amplification efficiency based on a comparative study. In this study, effective guidelines for DNA decontamination were developed. The method employed ensured that surface DNA contamination could be effectively identified and eliminated. Furthermore, our study highlighted the importance of overall quality assurance and good clinical laboratory practices for preventing contamination, which are key factors for compliance with regulatory or accreditation requirements. Taken together, we provided the evidence that the presented scheme ranged from troubleshooting to the elimination of surface contamination, could serve as critical foundation for developing regular environmental surveillance guidelines for PCR laboratories. © 2017 Wiley Periodicals, Inc.

  6. DO TIE LABORATORY BASED ASSESSMENT METHODS REALLY PREDICT FIELD EFFECTS?

    Science.gov (United States)

    Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both porewaters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question of whethe...

  7. Report of the results of the International Clinical Cytometry Society and American Society for Clinical Pathology workload survey of clinical flow cytometry laboratories.

    Science.gov (United States)

    Wolniak, Kristy; Goolsby, Charles; Choi, Sarah; Ali, Asma; Serdy, Nina; Stetler-Stevenson, Maryalice

    2017-11-01

    Thorough review of current workload, staffing, and testing practices in clinical laboratories allows for optimization of laboratory efficiency and quality. This information is largely missing with regard to clinical flow cytometry laboratories. The purpose of this survey is to provide comprehensive, current, and accurate data on testing practices and laboratory staffing in clinical laboratories performing flow cytometric studies. Survey data was collected from flow cytometry laboratories through the ASCP website. Data was collected on the workload during a 1-year time period of full-time and part-time technical and professional (M.D./D.O./Ph.D. or equivalent) flow cytometry employees. Workload was examined as number of specimens and tubes per full time equivalent (FTE) technical and professional staff. Test complexity, test result interpretation, and reporting practices were also evaluated. There were 205 respondent laboratories affiliated predominantly with academic and health system institutions. Overall, 1,132 FTE employees were reported with 29% professional FTE employees and 71% technical. Fifty-one percent of the testing performed was considered high complexity and 49% was low complexity. The average number of tubes per FTE technologist was 1,194 per year and the average number of specimens per FTE professional was 1,659 per year. The flow cytometry reports were predominantly written by pathologists (57%) and were typically written as a separate report (58%). This survey evaluates the overall status of the current practice of clinical flow cytometry and provides a comprehensive dataset as a framework to help laboratory departments, directors, and managers make appropriate, cost-effective staffing decisions. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  8. Results of the independent radiological verification survey of the remedial action performed at the former Alba Craft Laboratory site, Oxford, Ohio, (OXO001)

    International Nuclear Information System (INIS)

    Kleinhans, K.R.; Murray, M.E.; Carrier, R.F.

    1996-04-01

    Between October 1952 and February 1957, National Lead of Ohio (NLO), a primary contractor for the Atomic Energy Commission (AEC), subcontracted certain uranium machining operations to Alba Craft Laboratory, Incorporated, located at 10-14 West Rose Avenue, Oxford, Ohio. In 1992, personnel from Oak Ridge National Laboratory (ORNL) confirmed the presence of residual radioactive materials from the AEC-related operations in and around the facility in amounts exceeding the applicable Department of Energy (DOE) guidelines. Although the amount of uranium found on the property posed little health hazard if left undisturbed, the levels were sufficient to require remediation to bring radiological conditions into compliance with current guidelines, thus ensuring that the public and the environment are protected. A team from ORNL conducted a radiological verification survey of the former Alba Craft Laboratory property between December 1994 and February 1995. The survey was conducted at the request of DOE and included directly measured radiation levels, the collection and analysis of soil samples to determine concentrations of uranium and certain other radionuclides, and comparison of these data to the guidelines. This document reports the findings of this survey. The results of the independent verification survey of the former Alba Craft Laboratory property demonstrate that all contaminated areas have been remediated to radionuclide concentrations and activity levels below the applicable guideline limits set by DOE

  9. Results from the geological surveys carried out in the Bure laboratory's drifts

    International Nuclear Information System (INIS)

    Rebours, Herve; Righini, Celine

    2010-01-01

    Document available in extended abstract form only. After the government's authorization to build and operate an underground laboratory, Andra started the investigation works in November 99 on the Meuse/Haute-Marne URL site. The Meuse/Haute-Marne URL is located at the border of the Champagne-Ardenne and Lorraine regions, on the township of Bure in the Callovo-Oxfordian clay-rich rock. At this place, the layer is about 135 m-thick and lies at a depth of 417 m to 552 m. The construction of the underground installations started in August 2000 with the sinking of the main shaft and the first phase of diggings was completed on the 27 April 2006 when it linked up with the south drift of the laboratory. The laboratory consists in two vertical shafts crossing the 505-m thick sedimentary cover and two levels of experimental drifts dug in Callovo-Oxfordian formation. The first experimental drift dug at -445 m with a drill-and-blast method with steps of 2.4 m. The technical and experimental drifts at the main level (-490 m of depth) were dug with a hydraulic stone crusher. The aims of the geological surveys carried out during the drifts digging are to observe the lateral variation of the lithology, if there is one, to confirm the absence of fault and the geometry of the argillites formation. These works should also allow to characterize the natural or inducted fracturing (EDZ - Excavation Damaged Zone) induced by the digging by a sedimentary and structural follow-up. The EDZ characterization has been established from the geological survey of the drift face and sidewalls carried out from 1 to 5 meters in the drifts, and completed by the structural analysis of the cores of the boreholes drilled for the experimentations' equipments. After the safe keeping of the front, the geological team goes down to carry out the survey which consists in a lithologic and sedimentary mapping, a structural survey for the understanding of joints distribution and EDZ characterization, and

  10. Underwater sediment-contact radiation survey method

    International Nuclear Information System (INIS)

    Lee, D.R.; St. Aubin, M.; Welch, S.J.

    1991-01-01

    The authors are striving to produce a practical system for mapping lateral distributions in gamma activity on submerged sediments. This is in response to the need for quality control and interpretation of data obtainable by sediment sampling and analyses near nuclear utilities. A prototype gamma probe has been constructed and tested. The prototype is essentially a background survey meter packaged in a 53-cm-long x 5.4-cm-diam waterproof vehicle. This usage-shaped vehicle is connected to a cable for towing in contact with bottom sediments of lakes, rivers, and coastal waters. This vehicle, or sediment probe as it is called, was initially developed for measuring sediment electrical conductances, a parameter that can be used to locate underwater areas of groundwater and contaminant upwelling. During towing, the probe does not roll or twist around its longitudinal axis by more than 10 deg, so that sensors, which have been fixed within the vehicle, can be oriented to look up, down, or sideways. In over 450 lin-km of underwater survey, only a single sediment probe has been irretrievably snagged on sunken rocks or other debris. Work in the Ottawa River near the Chalk River Laboratories has shown good agreement among point measurements of river sediment with continuous measurements using the moving probe

  11. Aerial radiological survey of the Industrial Reactor Laboratory and surrounding area Plainsboro, New Jersey

    International Nuclear Information System (INIS)

    1980-12-01

    An airborne radiological survey of a 6 km 2 area centered over the Industrial Reactor Laboratory was made 25-27 July 1979. Detected radioisotopes and their associated gamma ray exposure rates were consistent with that expected from normal background emitters, except at two locations described in this report. Count rates observed at 46 m altitude were converted to exposure rates at 1 m above the ground and are presented in the form of an isopleth map

  12. Laboratory and Self-Report Methods to Assess Reappraisal and Distraction in Youth.

    Science.gov (United States)

    Bettis, Alexandra H; Henry, Lauren; Prussien, Kemar V; Vreeland, Allison; Smith, Michele; Adery, Laura H; Compas, Bruce E

    2018-06-07

    Coping and emotion regulation are central features of risk and resilience in childhood and adolescence, but research on these constructs has relied on different methods of assessment. The current study aimed to bridge the gap between questionnaire and experimental methods of measuring secondary control coping strategies, specifically distraction and cognitive reappraisal, and examine associations with symptoms of anxiety and depression in youth. A community sample of 70 youth (ages 9-15) completed a novel experimental coping and emotion regulation paradigm and self-report measures of coping and emotion regulation and symptoms. Findings indicate that use of distraction and reappraisal during the laboratory paradigm was associated with lower levels of negative emotion during the task. Youth emotion ratings while implementing distraction, but not reappraisal, during the laboratory task were associated with youth self-reported use of secondary control coping in response to family stress. Youth symptoms of anxiety and depression were also significantly positively associated with negative emotion ratings during the laboratory task, and both laboratory task and self-reported coping and emotion regulation accounted for significant variance in symptoms in youth. Both questionnaire and laboratory methods to assess coping and emotion regulation in youth are important for understanding these processes as possible mechanisms of risk and resilience and continued integration of these methods is a priority for future research.

  13. Project-Based Learning in Undergraduate Environmental Chemistry Laboratory: Using EPA Methods to Guide Student Method Development for Pesticide Quantitation

    Science.gov (United States)

    Davis, Eric J.; Pauls, Steve; Dick, Jonathan

    2017-01-01

    Presented is a project-based learning (PBL) laboratory approach for an upper-division environmental chemistry or quantitative analysis course. In this work, a combined laboratory class of 11 environmental chemistry students developed a method based on published EPA methods for the extraction of dichlorodiphenyltrichloroethane (DDT) and its…

  14. Monitoring and reporting of preanalytical errors in laboratory medicine: the UK situation.

    Science.gov (United States)

    Cornes, Michael P; Atherton, Jennifer; Pourmahram, Ghazaleh; Borthwick, Hazel; Kyle, Betty; West, Jamie; Costelloe, Seán J

    2016-03-01

    Most errors in the clinical laboratory occur in the preanalytical phase. This study aimed to comprehensively describe the prevalence and nature of preanalytical quality monitoring practices in UK clinical laboratories. A survey was sent on behalf of the Association for Clinical Biochemistry and Laboratory Medicine Preanalytical Working Group (ACB-WG-PA) to all heads of department of clinical laboratories in the UK. The survey captured data on the analytical platform and Laboratory Information Management System in use; which preanalytical errors were recorded and how they were classified and gauged interest in an external quality assurance scheme for preanalytical errors. Of the 157 laboratories asked to participate, responses were received from 104 (66.2%). Laboratory error rates were recorded per number of specimens, rather than per number of requests in 51% of respondents. Aside from serum indices for haemolysis, icterus and lipaemia, which were measured in 80% of laboratories, the most common errors recorded were booking-in errors (70.1%) and sample mislabelling (56.9%) in laboratories who record preanalytical errors. Of the laboratories surveyed, 95.9% expressed an interest in guidance on recording preanalytical error and 91.8% expressed interest in an external quality assurance scheme. This survey observes a wide variation in the definition, repertoire and collection methods for preanalytical errors in the UK. Data indicate there is a lot of interest in improving preanalytical data collection. The ACB-WG-PA aims to produce guidance and support for laboratories to standardize preanalytical data collection and to help establish and validate an external quality assurance scheme for interlaboratory comparison. © The Author(s) 2015.

  15. Survey of industry methods for producing highly reliable software

    International Nuclear Information System (INIS)

    Lawrence, J.D.; Persons, W.L.

    1994-11-01

    The Nuclear Reactor Regulation Office of the US Nuclear Regulatory Commission is charged with assessing the safety of new instrument and control designs for nuclear power plants which may use computer-based reactor protection systems. Lawrence Livermore National Laboratory has evaluated the latest techniques in software reliability for measurement, estimation, error detection, and prediction that can be used during the software life cycle as a means of risk assessment for reactor protection systems. One aspect of this task has been a survey of the software industry to collect information to help identify the design factors used to improve the reliability and safety of software. The intent was to discover what practices really work in industry and what design factors are used by industry to achieve highly reliable software. The results of the survey are documented in this report. Three companies participated in the survey: Computer Sciences Corporation, International Business Machines (Federal Systems Company), and TRW. Discussions were also held with NASA Software Engineering Lab/University of Maryland/CSC, and the AIAA Software Reliability Project

  16. A loop-mediated isothermal amplification method for a differential identification of Taenia tapeworms from human: application to a field survey.

    Science.gov (United States)

    Nkouawa, Agathe; Sako, Yasuhito; Li, Tiaoying; Chen, Xingwang; Nakao, Minoru; Yanagida, Tetsuya; Okamoto, Munehiro; Giraudoux, Patrick; Raoul, Francis; Nakaya, Kazuhiro; Xiao, Ning; Qiu, Jiamin; Qiu, Dongchuan; Craig, Philip S; Ito, Akira

    2012-12-01

    In this study, we applied a loop-mediated isothermal amplification method for identification of human Taenia tapeworms in Tibetan communities in Sichuan, China. Out of 51 proglottids recovered from 35 carriers, 9, 1, and 41 samples were identified as Taenia solium, Taenia asiatica and Taenia saginata, respectively. Same results were obtained afterwards in the laboratory, except one sample. These results demonstrated that the LAMP method enabled rapid identification of parasites in the field surveys, which suggested that this method would contribute to the control of Taenia infections in endemic areas. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Porosity measurements of crystalline rocks by laboratory and geophysical methods

    International Nuclear Information System (INIS)

    Alexander, J.; Hall, D.H.; Storey, B.C.

    1981-12-01

    Porosity values of igneous and metamorphic crystalline rocks have been determined from core samples taken at specific depths from Altnabreac, by a combination of laboratory and geophysical techniques. Using resaturation and mercury injection methods in three laboratories within I.G.S., porosity values have been derived and the effect of variations in the measuring techniques and results obtained have been compared. Comparison of inter-laboratory porosity values illustrates that systematic errors are present, resulting in higher porosity values for samples subjected to re-testing. This is considered to be caused by the variable nature of the initial samples combined with the inability to completely dry or resaturate samples during a second testing. Geophysical techniques for determining in situ porosity using the neutron log have been carried out in borehole ALA. The neutron log has been calibrated with laboratory derived porosity values and an empirical formula derived enabling porosity values to be ascribed throughout the logged borehole ALA. Comparison of the porosity results from Altnabreac with crystalline samples elsewhere in America, Europe and the U.K. suggest that porosities at Altnabreac are lower than average. However, very few publications concerned with water movement in crystalline areas actually state the method used. (author)

  18. We’re Working On It: Transferring the Sloan Digital Sky Survey from Laboratory to Library

    OpenAIRE

    Sands, Ashley E.; Borgman, Christine L.; Traweek, Sharon; Wynholds, Laura A.

    2014-01-01

    This article reports on the transfer of a massive scientific dataset from a national laboratory to a university library, and from one kind of workforce to another. We use the transfer of the Sloan Digital Sky Survey (SDSS) archive to examine the emergence of a new workforce for scientific research data management. Many individuals with diverse educational backgrounds and domain experience are involved in SDSS data management: domain scientists, computer scientists, software and systems engin...

  19. Core courses in public health laboratory science and practice: findings from 2006 and 2011 surveys.

    Science.gov (United States)

    DeBoy, John M; Beck, Angela J; Boulton, Matthew L; Kim, Deborah H; Wichman, Michael D; Luedtke, Patrick F

    2013-01-01

    We identified academic training courses or topics most important to the careers of U.S. public health, environmental, and agricultural laboratory (PHEAL) scientist-managers and directors, and determined what portions of the national PHEAL workforce completed these courses. We conducted electronic national surveys in 2006 and 2011, and analyzed data using numerical ranking, Chi-square tests comparing rates, and Spearman's formula measuring rank correlation. In 2006, 40 of 50 PHEAL directors identified 56 course topics as either important, useful, or not needed for someone in their position. These course topics were then ranked to provide a list of 31 core courses. In 2011, 1,659 of approximately 5,555 PHEAL scientific and technical staff, using a subset of 25 core courses, evidenced higher core course completion rates associated with higher-level job classification, advanced academic degree, and age. The 2011 survey showed that 287 PHEAL scientist-managers and directors, on average, completed 37.7% (n=5/13) of leadership/managerial core courses and 51.7% (n=6/12) of scientific core courses. For 1,659 laboratorians in all scientific and technical classifications, core-subject completion rates were higher in local laboratories (42.8%, n=11/25) than in state (36.0%, n=9/25), federal (34.4%, n=9/25), and university (31.2%, n=8/25) laboratories. There is a definable range of scientific, leadership, and managerial core courses needed by PHEAL scientist-managers and directors to function effectively in their positions. Potential PHEAL scientist-managers and directors need greater and continuing access to these courses, and academic and practice entities supporting development of this workforce should adopt curricula and core competencies aligned with these course topics.

  20. Tour of the Standards and Calibrations Laboratory

    International Nuclear Information System (INIS)

    Elliott, J.H.

    1978-01-01

    This tour of Lawrence Livermore Laboratory's Standards and Calibrations Laboratory is intended as a guide to the capabilities of and services offered by this unique laboratory. Described are the Laboratory's ability to provide radiation fields and measurements for dosimeters, survey instruments, spectrometers, and sources and its available equipment and facilities. The tour also includes a survey of some Health Physics and interdepartmental programs supported by the Standards and Calibrations Laboratory and a listing of applicable publications

  1. Laboratory methods for diagnosis and detection of drug resistant ...

    African Journals Online (AJOL)

    Data source: Published series of peer reviewed journals and manuals written on laboratory methods that are currently used for diagnosis and detection of drug resistance of Mycobacterium tuberculosis complex were reviewed using the index medicus, pubmed and medline search. Conventional bacteriological microscopy ...

  2. Prenotification, Incentives, and Survey Modality: An Experimental Test of Methods to Increase Survey Response Rates of School Principals

    Science.gov (United States)

    Jacob, Robin Tepper; Jacob, Brian

    2012-01-01

    Teacher and principal surveys are among the most common data collection techniques employed in education research. Yet there is remarkably little research on survey methods in education, or about the most cost-effective way to raise response rates among teachers and principals. In an effort to explore various methods for increasing survey response…

  3. Total error components - isolation of laboratory variation from method performance

    International Nuclear Information System (INIS)

    Bottrell, D.; Bleyler, R.; Fisk, J.; Hiatt, M.

    1992-01-01

    The consideration of total error across sampling and analytical components of environmental measurements is relatively recent. The U.S. Environmental Protection Agency (EPA), through the Contract Laboratory Program (CLP), provides complete analyses and documented reports on approximately 70,000 samples per year. The quality assurance (QA) functions of the CLP procedures provide an ideal data base-CLP Automated Results Data Base (CARD)-to evaluate program performance relative to quality control (QC) criteria and to evaluate the analysis of blind samples. Repetitive analyses of blind samples within each participating laboratory provide a mechanism to separate laboratory and method performance. Isolation of error sources is necessary to identify effective options to establish performance expectations, and to improve procedures. In addition, optimized method performance is necessary to identify significant effects that result from the selection among alternative procedures in the data collection process (e.g., sampling device, storage container, mode of sample transit, etc.). This information is necessary to evaluate data quality; to understand overall quality; and to provide appropriate, cost-effective information required to support a specific decision

  4. ORGANIZATION AND METHOD FOR THE REMOTE LABORATORY WORK OF GENERAL TECHNICAL DISCIPLINE

    Directory of Open Access Journals (Sweden)

    Alfia Sh. Salakhova

    2014-01-01

    Full Text Available The article is devoted to the important problem – use of distant technologies in engineering education in the laboratory experiments. The role of distant experiment in the modern engineering education is discussed. The authors consider structure of the distant system to real experiments control and the method of realization distant laboratory work in the educational process. The analysis of distant laboratory work effectiveness is discussed. 

  5. Continuous Analytical Performances Monitoring at the On-Site Laboratory through Proficiency, Inter-Laboratory Testing and Inter-Comparison Analytical Methods

    International Nuclear Information System (INIS)

    Duhamel, G.; Decaillon, J.-G.; Dashdondog, S.; Kim, C.-K.; Toervenyi, A.; Hara, S.; Kato, S.; Kawaguchi, T.; Matsuzawa, K.

    2015-01-01

    Since 2008, as one measure to strengthen its quality management system, the On-Site Laboratory for nuclear safeguards at the Rokkasho Reprocessing Plant, has increased its participation in domestic and international proficiency and inter-laboratory testing for the purpose of determining analytical method accuracy, precision and robustness but also to support method development and improvement. This paper provides a description of the testing and its scheduling. It presents the way the testing was optimized to cover most of the analytical methods at the OSL. The paper presents the methodology used for the evaluation of the obtained results based on Analysis of variance (ANOVA). Results are discussed with respect to random, systematic and long term systematic error. (author)

  6. A preliminary survey of the National Wetlands Inventory as mapped for the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Hampton, N.L.; Rope, R.C.; Glennon, J.M.; Moor, K.S.

    1995-02-01

    Approximately 135 areas within the boundaries of the Idaho National Engineering Laboratory (INEL) have been mapped as wetland habitat as part of the United States Fish and Wildlife Service (FWS) National Wetlands Inventory (NWI). A preliminary survey of these wetlands was conducted to examine their general characteristics and status, to provide an estimation of relative ecological importance, to identify additional information needed to complete ecological characterization of important INEL wetlands, and to identify high priority wetland areas on the INEL. The purpose of the survey was to provide information to support the preparation of the Environmental Restoration and Waste Management (ER ampersand WM) Environmental Impact Statement (EIS). Information characterizing general vegetation, hydrology, wildlife use, and archaeology was collected at 105 sample sites on the INEL. Sites representing NWI palustrine, lacustrine, and riverine wetlands (including manmade), and areas unmapped or unclassified by the NWI were included in the sample. The field information was used to develop a preliminary ranking of relative ecological importance for each wetland visited during this survey. Survey limitations are identified

  7. Biological variables for the site survey of surface ecosystems - existing data and survey methods

    International Nuclear Information System (INIS)

    Kylaekorpi, Lasse; Berggren, Jens; Larsson, Mats; Liberg, Maria; Rydgren, Bernt

    2000-06-01

    In the process of selecting a safe and environmentally acceptable location for the deep level repository of nuclear waste, site surveys will be carried out. These site surveys will also include studies of the biota at the site, in order to assure that the chosen site will not conflict with important ecological interests, and to establish a thorough baseline for future impact assessments and monitoring programmes. As a preparation to the site survey programme, a review of the variables that need to be surveyed is conducted. This report contains the review for some of those variables. For each variable, existing data sources and their characteristics are listed. For those variables for which existing data sources are inadequate, suggestions are made for appropriate methods that will enable the establishment of an acceptable baseline. In this report the following variables are reviewed: Fishery, Landscape, Vegetation types, Key biotopes, Species (flora and fauna), Red-listed species (flora and fauna), Biomass (flora and fauna), Water level, water retention time (incl. water body and flow), Nutrients/toxins, Oxygen concentration, Layering, stratification, Light conditions/transparency, Temperature, Sediment transport, (Marine environments are excluded from this review). For a major part of the variables, the existing data coverage is most likely insufficient. Both the temporal and/or the geographical resolution is often limited, which means that complementary surveys must be performed during (or before) the site surveys. It is, however, in general difficult to make exact judgements on the extent of existing data, and also to give suggestions for relevant methods to use in the site surveys. This can be finally decided only when the locations for the sites are decided upon. The relevance of the different variables also depends on the environmental characteristics of the sites. Therefore, we suggest that when the survey sites are selected, an additional review is

  8. Biological variables for the site survey of surface ecosystems - existing data and survey methods

    Energy Technology Data Exchange (ETDEWEB)

    Kylaekorpi, Lasse; Berggren, Jens; Larsson, Mats; Liberg, Maria; Rydgren, Bernt [SwedPower AB, Stockholm (Sweden)

    2000-06-01

    In the process of selecting a safe and environmentally acceptable location for the deep level repository of nuclear waste, site surveys will be carried out. These site surveys will also include studies of the biota at the site, in order to assure that the chosen site will not conflict with important ecological interests, and to establish a thorough baseline for future impact assessments and monitoring programmes. As a preparation to the site survey programme, a review of the variables that need to be surveyed is conducted. This report contains the review for some of those variables. For each variable, existing data sources and their characteristics are listed. For those variables for which existing data sources are inadequate, suggestions are made for appropriate methods that will enable the establishment of an acceptable baseline. In this report the following variables are reviewed: Fishery, Landscape, Vegetation types, Key biotopes, Species (flora and fauna), Red-listed species (flora and fauna), Biomass (flora and fauna), Water level, water retention time (incl. water body and flow), Nutrients/toxins, Oxygen concentration, Layering, stratification, Light conditions/transparency, Temperature, Sediment transport, (Marine environments are excluded from this review). For a major part of the variables, the existing data coverage is most likely insufficient. Both the temporal and/or the geographical resolution is often limited, which means that complementary surveys must be performed during (or before) the site surveys. It is, however, in general difficult to make exact judgements on the extent of existing data, and also to give suggestions for relevant methods to use in the site surveys. This can be finally decided only when the locations for the sites are decided upon. The relevance of the different variables also depends on the environmental characteristics of the sites. Therefore, we suggest that when the survey sites are selected, an additional review is

  9. Methodical recommendations for power unit comprehensive engineering and radiation survey

    International Nuclear Information System (INIS)

    Nosovskij, A.V.

    2000-01-01

    The article describes power unit radiation survey methods developed and applied during conduction of Ch NPP unit I Comprehensive Engineering Radiation Survey. Special requirements for units under decommissioning, main survey principals, criteria for definition of volume and the order of survey for various systems of a NPP Unit are included

  10. Knowledge and practices of pharmaceutical laboratory workers on laboratory safety

    Directory of Open Access Journals (Sweden)

    Esra Emerce

    2017-09-01

    Full Text Available Laboratories are classified as very hazardous workplaces. Objective: The aim of this descriptive study was to determine the knowledge and practice of laboratory safety by analysts and technicians in the laboratories of the Turkish Medicine and Medical Devices Agency. Methods:  85.0% (n=93 of the workers (n=109 was reached. A pre-tested, laboratory safety oriented, self-administered questionnaire was completed under observation. Results: Participants were mostly female (66,7%, had 12.8±8.2 years of laboratory experience and worked 24.6±10.3 hours per week. 53.8% of the employees generally worked with flammable and explosive substances, 29.0% with acute toxic or carcinogenic chemicals and 30.1% with physical dangers. Of all surveyed, 14.0% had never received formal training on laboratory safety. The proportion of ‘always use’ of laboratory coats, gloves, and goggles were 84.9%, 66.7%, and 6.5% respectively. 11.9% of the participants had at least one serious injury throughout their working lives and 24.7% had at least one small injury within the last 6 months. Among these injuries, incisions, bites and tears requiring no stiches (21.0% and the inhalation of chemical vapors (16.1% took first place. The mean value for the number of correct responses to questions on basic safety knowledge was 65.4±26.5, out of a possible 100. Conclusion: Overall, the participants have failed in some safety practices and have been eager to get regular education on laboratory safety.  From this point onwards, it would be appropriate for the employers to organize periodic trainings on laboratory safety.Keywords: Health personnel, laboratory personnel, occupational health, occupational safety, pharmacy

  11. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of the total phosphorus by a Kjeldahl digestion method and an automated colorimetric finish that includes dialysis

    Science.gov (United States)

    Patton, Charles J.; Truitt, Earl P.

    1992-01-01

    A method to determine total phosphorus (TP) in the same digests prepared for total Kjeldahl nitrogen (TKN) determinations is desribed. The batch, high-temperature (block digester), HG(II)-catalyzed digestion step is similar to U.S. Geological Survey methods I-2552-85/I-4552-85 and U.S. Environmental Protection Agency method 365.4 except that sample and reagent volumes are halved. Prepared digests are desolvated at 220 degrees Celsius and digested at 370 degrees Celsius in separate block digesters set at these temperatures, rather than in a single, temperature-programmed block digester. This approach is used in the method escribed here, which permits 40 calibrants, reference waters, and smaples to be digested and resolvated in about an hour. Orthophosphate ions originally present in samples, along with those released during the digestion step, are determined colorimetrically at a rate of 90 tests per hour by an automated version of the phosphoantimonylmolybdenum blue procedure. About 100 microliters of digest are required per determination. The upper concentration limit is 2 milligrams per liter (mg/L) with a method detection limt of 0.01 mg/L. Repeatability for a sample containing approximately 1.6 mg/L of TP in a high suspended-solids matrix is 0.7 percent. Between-day precision for the same sample is 5.0 percent. A dialyzer in the air-segmented continuous flow analyzer provides on-line digest cleanup, eliminated particulates that otherwise would interfere in the colorimetric finish. An single-channel analyzer can process the resolvated digests from two pairs of block digesters each hour. Paired t-test analysis of TP concentrations for approximately 1,600 samples determined by the new method (U.S. Geologial Survey methods I-2610-91 and I-4610-91) and the old method (U.S. Geological Survey methods I-2600-85 and I-4600-85) revealed positive bias in the former of 0.02 to 0.04 mg/L for surface-water samples in agreement with previous studies. Concentrations of total

  12. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    International Nuclear Information System (INIS)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.; Moore, L.L.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations at or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. 13 refs., 2 figs., 6 tabs

  13. Post-remedial-action survey report for Kinetic Experiment Water Boiler Reactor Facility, Santa Susana Field Laboratories, Rockwell International, Ventura County, California

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.; Justus, A.L.

    1981-10-01

    Rockwell International's Santa Susana Laboratories in Ventura County, California, have been the site of numerous federally-funded contracted projects involving the use of radioactive materials. Among these was the Kinetics Experiment Water Boiler (KEWB) Reactor which was operated under the auspices of the US Atomic Energy Commission (AEC). The KEWB Reactor was last operated in 1966. The facility was subsequently declared excess and decontamination and decommissioning operations were conducted during the first half of calendar year 1975. The facility was completely dismantled and the site graded to blend with the surrounding terrain. During October 1981, a post-remedial-action (certification) survey of the KEWB site was conducted on the behalf of the US Department of Energy by the Radiological Survey Group (RSG) of the Occupational Health and Safety Division's Health Physics Section (OHS/HP) of Argonne National Laboratory (ANL). The survey confirmed that the site was free from contamination and could be released for unrestricted use

  14. Laboratory Sequence in Computational Methods for Introductory Chemistry

    Science.gov (United States)

    Cody, Jason A.; Wiser, Dawn C.

    2003-07-01

    A four-exercise laboratory sequence for introductory chemistry integrating hands-on, student-centered experience with computer modeling has been designed and implemented. The progression builds from exploration of molecular shapes to intermolecular forces and the impact of those forces on chemical separations made with gas chromatography and distillation. The sequence ends with an exploration of molecular orbitals. The students use the computers as a tool; they build the molecules, submit the calculations, and interpret the results. Because of the construction of the sequence and its placement spanning the semester break, good laboratory notebook practices are reinforced and the continuity of course content and methods between semesters is emphasized. The inclusion of these techniques in the first year of chemistry has had a positive impact on student perceptions and student learning.

  15. Errors in clinical laboratories or errors in laboratory medicine?

    Science.gov (United States)

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  16. Optimal power flow: a bibliographic survey I. Formulations and deterministic methods

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Stephen [Colorado School of Mines, Department of Electrical Engineering and Computer Science, Golden, CO (United States); Steponavice, Ingrida [University of Jyvaskyla, Department of Mathematical Information Technology, Agora (Finland); Rebennack, Steffen [Colorado School of Mines, Division of Economics and Business, Golden, CO (United States)

    2012-09-15

    Over the past half-century, optimal power flow (OPF) has become one of the most important and widely studied nonlinear optimization problems. In general, OPF seeks to optimize the operation of electric power generation, transmission, and distribution networks subject to system constraints and control limits. Within this framework, however, there is an extremely wide variety of OPF formulations and solution methods. Moreover, the nature of OPF continues to evolve due to modern electricity markets and renewable resource integration. In this two-part survey, we survey both the classical and recent OPF literature in order to provide a sound context for the state of the art in OPF formulation and solution methods. The survey contributes a comprehensive discussion of specific optimization techniques that have been applied to OPF, with an emphasis on the advantages, disadvantages, and computational characteristics of each. Part I of the survey (this article) provides an introduction and surveys the deterministic optimization methods that have been applied to OPF. Part II of the survey examines the recent trend towards stochastic, or non-deterministic, search techniques and hybrid methods for OPF. (orig.)

  17. Factors influencing biosafety level and lai among the staff of medical laboratories

    OpenAIRE

    Anna Kozajda; Karolina Bródka; Irena Szadkowska-Stańczyk

    2013-01-01

    Background: The aim of the study was to assess the biological risks of medical laboratory employees with particular focus on laboratory acquired infection (LAI), activities having the greatest risk, accidents with biological material, post exposure procedure, preventive measures and workers' knowledge about biological exposure. Materials and Methods: The study involved 9 laboratories. A questionnaire survey was attended by 123 employees and 9 heads of these units with the use of two questionn...

  18. Confirmatory radiological survey of the BORAX-V turbine building Idaho National Engineering Laboratory, Idaho Falls, Idaho

    International Nuclear Information System (INIS)

    Stevens, G.H.; Coleman, R.L.; Jensen, M.K.; Pierce, G.A.; Egidi, P.V.; Mather, S.K.

    1993-01-01

    An independent assessment of the remediation of the BORAX-V (Boiling Water Reactor Experiment) turbine building at the Idaho National Engineering Laboratory (INEL), Idaho Falls, Idaho, was accomplished by the Oak Ridge National Laboratory Pollutant Assessments Group (ORNL/PAG). The purpose of the assessment was to confirm the site's compliance with applicable Department of Energy guidelines. The assessment included reviews of both the decontamination and decommissioning Plan and data provided from the pre- and post-remedial action surveys and an independent verification survey of the facility. The independent verification survey included determination of background exposure rates and soil concentrations, beta-gamma and gamma radiation scans, smears for detection of removable contamination, and direct measurements for alpha and beta-gamma radiation activity on the basement and mezzanine floors and the building's interior and exterior walls. Soil samples were taken, and beta-gamma and gamma radiation exposure rates were measured on areas adjacent to the building. Results of measurements on building surfaces at this facility were within established contamination guidelines except for elevated beta-gamma radiation levels located on three isolated areas of the basement floor. Following remediation of these areas, ORNL/PAG reviewed the remedial action contractor's report and agreed that remediation was effective in removing the source of the elevated direct radiation. Results of all independent soil analyses for 60 Co were below the detection limit. The highest 137 Cs analysis result was 4.6 pCi/g; this value is below the INEL site-specific guideline of 10 pCi/g

  19. Underwater photography - A visual survey method

    Digital Repository Service at National Institute of Oceanography (India)

    Sharma, R.

    Content-Type text/plain; charset=UTF-8 173 Underwater photography - A visual survey method Rahul Sharma National Institute of Oceanography, Dona Paula, Goa-403004 rsharma@nio.org Introduction “Photography as a means of observing...-sea photographs were those made by Maurice Ewing and his co-workers during cruises on Atlantis in 1940-48. Their subject was the seafloor and their method of clicking was to trigger the camera mechanically when its mounting struck bottom. This is the only...

  20. Aerial radiological survey of the United States Department of Energy's Sandia National Laboratories and Inhalation Toxicology Research Institute, Albuquerque, New Mexico. Date of survey: April 1981

    International Nuclear Information System (INIS)

    Boyns, P.K.

    1982-05-01

    An aerial radiological survey of the Sandia National Laboratories (SNLA) and the Inhalation Toxicology Research Institute (ITRI) was carried out in April 1981 by EG and G, Inc. for the United States Department of Energy. The survey consisted of an airborne measurement of both natural and man-made gamma radiation from the terrain surface in and around the SNLA and ITRI site. These measurements allowed a determination of the surface terrestrial spatial distribution of isotope concentrations. Results are reported as exposure rates and man-made isopleths and are superimposed on 240 m/cm scale map of the area. Gamma ray energy spectra are also presented for the net man-made radioelements. Several areas of man-made activity were detected in the SNLA and ITRI survey. These areas were associated with normal operations at the SNLA, ITRI and Kirtland Air Force Base. The presence of 241 Am was not detected in any of the areas surveyed

  1. Does the Underground Sidewall Station Survey Method Meet MHSA ...

    African Journals Online (AJOL)

    Grobler, Hendrik

    The underground survey network in a deep level platinum mine in ... The time duration for peg installation during the initial phase of learning the method was ..... changes to the survey “hardware” including prisms, stems and attachment points ...

  2. An Overview of the Computational Physics and Methods Group at Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Randal Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-02-22

    CCS Division was formed to strengthen the visibility and impact of computer science and computational physics research on strategic directions for the Laboratory. Both computer science and computational science are now central to scientific discovery and innovation. They have become indispensable tools for all other scientific missions at the Laboratory. CCS Division forms a bridge between external partners and Laboratory programs, bringing new ideas and technologies to bear on today’s important problems and attracting high-quality technical staff members to the Laboratory. The Computational Physics and Methods Group CCS-2 conducts methods research and develops scientific software aimed at the latest and emerging HPC systems.

  3. An Adaptive Laboratory Evolution Method to Accelerate Autotrophic Metabolism

    DEFF Research Database (Denmark)

    Zhang, Tian; Tremblay, Pier-Luc

    2018-01-01

    Adaptive laboratory evolution (ALE) is an approach enabling the development of novel characteristics in microbial strains via the application of a constant selection pressure. This method is also an efficient tool to acquire insights on molecular mechanisms responsible for specific phenotypes. ALE...... autotrophically and reducing CO2 into acetate more efficiently. Strains developed via this ALE method were also used to gain knowledge on the autotrophic metabolism of S. ovata as well as other acetogenic bacteria....

  4. Assessing risk of draft survey by AHP method

    Science.gov (United States)

    Xu, Guangcheng; Zhao, Kuimin; Zuo, Zhaoying; Liu, Gang; Jian, Binguo; Lin, Yan; Fan, Yukun; Wang, Fei

    2018-04-01

    The paper assesses the risks of vessel floating in the seawater for draft survey by using the analytic hierarchy process. On this basis, the paper established draft survey risk index from the view of draft reading, ballast water, fresh water, and calculation process and so on. Then the paper proposes the method to deal with risk assessment using one concrete sample.

  5. Laboratory Validation and Field Assessment of Petroleum Laboratory Technicians' Dermal Exposure to Crude Oil Using a Wipe Sampling Method.

    Science.gov (United States)

    Galea, Karen S; Mueller, Will; Arfaj, Ayman M; Llamas, Jose L; Buick, Jennifer; Todd, David; McGonagle, Carolyn

    2018-05-21

    Crude oil may cause adverse dermal effects therefore dermal exposure is an exposure route of concern. Galea et al. (2014b) reported on a study comparing recovery (wipe) and interception (cotton glove) dermal sampling methods. The authors concluded that both methods were suitable for assessing dermal exposure to oil-based drilling fluids and crude oil but that glove samplers may overestimate the amount of fluid transferred to the skin. We describe a study which aimed to further evaluate the wipe sampling method to assess dermal exposure to crude oil, with this assessment including extended sample storage periods and sampling efficiency tests being undertaken at environmental conditions to mimic those typical of outdoor conditions in Saudi Arabia. The wipe sampling method was then used to assess the laboratory technicians' actual exposure to crude oil during typical petroleum laboratory tasks. Overall, acceptable storage efficiencies up to 54 days were reported with results suggesting storage stability over time. Sampling efficiencies were also reported to be satisfactory at both ambient and elevated temperature and relative humidity environmental conditions for surrogate skin spiked with known masses of crude oil and left up to 4 h prior to wiping, though there was an indication of reduced sampling efficiency over time. Nineteen petroleum laboratory technicians provided a total of 35 pre- and 35 post-activity paired hand wipe samples. Ninety-three percent of the pre-exposure paired hand wipes were less than the analytical limit of detection (LOD), whereas 46% of the post-activity paired hand wipes were less than the LOD. The geometric mean paired post-activity wipe sample measurement was 3.09 µg cm-2 (range 1.76-35.4 µg cm-2). It was considered that dermal exposure most frequently occurred through direct contact with the crude oil (emission) or via deposition. The findings of this study suggest that the wipe sampling method is satisfactory in quantifying

  6. Survey method for radiological surveys of 300 FF-1 Operable Unit soil and materials

    International Nuclear Information System (INIS)

    Greif, A.A.

    1997-06-01

    This technical basis document is to be used to survey soils at the 300-FF-1 Operable Unit during remediation of the site. Its purpose is to provide a basis for the survey methods to be employed by the Radiological Control Technician to determine if excavated areas require continued remediation in accordance with the Record of Decision for the operable unit

  7. Programs and analytical methods for the U.S. Geological Survey acid-rain quality-assurance project. Water Resources Investigation

    International Nuclear Information System (INIS)

    See, R.B.; Willoughby, T.C.; Brooks, M.H.; Gordon, J.D.

    1990-01-01

    The U.S. Geological Survey operates four programs to provide external quality-assurance of wet deposition monitoring by the National Atmospheric Deposition Program and the National Trends Network. An intersite-comparison program assesses the precision and bias of onsite determinations of pH and specific conductance made by site operators. A blind-audit program is used to assess the effect of routine sample-handling procedures and transportation on the precision and bias of wet-deposition data. An interlaboratory-comparison program is used to assess analytical results from three or more laboratories, which routinely analyze wet-deposition samples from the major North American networks, to determine if comparability exists between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. A collocated-sampler program is used to estimate the precision of wet/dry precipitation sampling throughout the National Atmospheric Deposition Program and the National Trends Network, to assess the variability of diverse spatial arrays, and to evaluate the impact of violations of specific site criteria. The report documents the procedures and analytical methods used in these four quality-assurance programs

  8. Development of laboratory acceleration test method for service life prediction of concrete structures

    International Nuclear Information System (INIS)

    Cho, M. S.; Song, Y. C.; Bang, K. S.; Lee, J. S.; Kim, D. K.

    1999-01-01

    Service life prediction of nuclear power plants depends on the application of history of structures, field inspection and test, the development of laboratory acceleration tests, their analysis method and predictive model. In this study, laboratory acceleration test method for service life prediction of concrete structures and application of experimental test results are introduced. This study is concerned with environmental condition of concrete structures and is to develop the acceleration test method for durability factors of concrete structures e.g. carbonation, sulfate attack, freeze-thaw cycles and shrinkage-expansion etc

  9. Multi-laboratory testing of a screening method for world trade center (WTC) collapse dust

    International Nuclear Information System (INIS)

    Rosati, Jacky A.; Bern, Amy M.; Willis, Robert D.; Blanchard, Fredrick T.; Conner, Teri L.; Kahn, Henry D.; Friedman, David

    2008-01-01

    The September 11, 2001 attack on the World Trade Center (WTC) covered a large area of downtown New York City with dust and debris. This paper describes the testing of an analytical method designed to evaluate whether sampled dust contains dust that may have originated from the collapse of the WTC. Using dust samples collected from locations affected and not affected (referred to as 'background' locations) by the collapse, a scanning electron microscopy (SEM) analysis method was developed to screen for three materials that are believed to be present in large quantities in WTC dusts: slag wool, concrete, and gypsum. An inter-laboratory evaluation of the method was implemented by having eight laboratories analyze a number of 'blind' dust samples, consisting of confirmed background dust and confirmed background dust spiked with varying amounts of dust affected by the WTC collapse. The levels of gypsum and concrete in the spiked samples were indistinguishable from the levels in the background samples. Measurements of slag wool in dust demonstrated potential for distinguishing between spiked and background samples in spite of considerable within and between laboratory variability. Slag wool measurements appear to be sufficiently sensitive to distinguish dust spiked with 5% WTC-affected dust from 22 out of 25 background dust samples. Additional development work and inter-laboratory testing of the slag wool component will be necessary to improve the precision and accuracy of the method and reduce inter- and intra-laboratory variability from levels observed in the inter-laboratory evaluation

  10. A new method for eliciting three speaking styles in the laboratory

    OpenAIRE

    Harnsberger, James D.; Wright, Richard; Pisoni, David B.

    2008-01-01

    In this study, a method was developed to elicit three different speaking styles, reduced, citation, and hyperarticulated, using controlled sentence materials in a laboratory setting. In the first set of experiments, the reduced style was elicited by having twelve talkers read a sentence while carrying out a distractor task that involved recalling from short-term memory an individually-calibrated number of digits. The citation style corresponded to read speech in the laboratory. The hyperartic...

  11. Undergraduate Organic Chemistry Laboratory Safety

    Science.gov (United States)

    Luckenbaugh, Raymond W.

    1996-11-01

    Each organic chemistry student should become familiar with the educational and governmental laboratory safety requirements. One method for teaching laboratory safety is to assign each student to locate safety resources for a specific class laboratory experiment. The student should obtain toxicity and hazardous information for all chemicals used or produced during the assigned experiment. For example, what is the LD50 or LC50 for each chemical? Are there any specific hazards for these chemicals, carcinogen, mutagen, teratogen, neurotixin, chronic toxin, corrosive, flammable, or explosive agent? The school's "Chemical Hygiene Plan", "Prudent Practices for Handling Hazardous Chemicals in the Laboratory" (National Academy Press), and "Laboratory Standards, Part 1910 - Occupational Safety and Health Standards" (Fed. Register 1/31/90, 55, 3227-3335) should be reviewed for laboratory safety requirements for the assigned experiment. For example, what are the procedures for safe handling of vacuum systems, if a vacuum distillation is used in the assigned experiment? The literature survey must be submitted to the laboratory instructor one week prior to the laboratory session for review and approval. The student should then give a short presentation to the class on the chemicals' toxicity and hazards and describe the safety precautions that must be followed. This procedure gives the student first-hand knowledge on how to find and evaluate information to meet laboartory safety requirements.

  12. Laboratory Tests Turnaround Time in Outpatient and Emergency Patients in Nigeria: Results of A Physician Survey on Point of Care Testing

    Directory of Open Access Journals (Sweden)

    Bolodeoku J

    2017-05-01

    Full Text Available Laboratory analytical turnaround time is a well-recognised indicator of how well a laboratory is performing and is sometimes regarded as the benchmark for laboratory performance. Methods: Total 104 doctors in public and private health institutions in Nigeria, spread across all six geo-political zones participated in survey requesting information on their experience with laboratory turnaround times in emergency situations (emergency room, special care baby unit, intensive care unit, dialysis unit and outpatient situations (general medicine and diabetes. Results: The average turnaround time in hours was 5.12, 8.35, 7.32 and 8.33 for the emergency room, special care baby unit, intensive care unit and dialysis unit, respectively. For the outpatient situations, the average turnaround time in hours was 10.74 and 15.70 hours for the diabetes and general medical outpatients. The median range (hours and modal range (hours for: the emergency room was 2-4 and <2; the special care baby unit was 4-8 and 4-8; the intensive care unit was 2-4 and 2-4; the dialysis unit was 4-8 and 4-8. The median range (hours and modal range (hours for: the general outpatient clinic was 12-24 and 12-24; the diabetic clinic was 4-8 and 12-24 hours. Conclusion: These turnaround time results are quite consistent with published data from other countries. However, there is some measure of improvement that is required in some areas to reduce the laboratory turnaround in the emergency situations. This could be overcome with the introduction of more point of care testing devices into emergency units.

  13. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    Science.gov (United States)

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists

  14. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-10-15

    We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF's test reports. Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety.

  15. Aerial radiological survey of the Brookhaven National Laboratory and surrounding area, May 1980

    International Nuclear Information System (INIS)

    Hobaugh, J.L.; Steiner, P.A.

    1984-01-01

    An aerial radiological survey was performed from 15 to 18 May 1980 over approximately a 21-square-kilometer (8-square-mile) area surrounding the Brookhaven National Laboratory (BNL). BNL is located in the center of Suffolk County, Long Island, New York. All gamma radiation data were collected by flying north-south lines spaced 91 meters (300 feet) apart at an altitude of 61 meters (200 feet) above ground level. A total of 17 anomalous areas were identified. The dominant isotopes found over these areas were cesium-137, manganese-54, and cobalt-60. All anomalies identified by the aerial measurements were correlated to site activities and storage facilities. 4 references, 18 figures, 1 table

  16. Use of TD ABC method for cost management in an accredited laboratory for physical and chemical testiry

    Directory of Open Access Journals (Sweden)

    Živković-Gabaldo Aleksandra N.

    2014-01-01

    Full Text Available Accreditation of a laboratory is verification of the competence of a laboratory regarding methods and procedures applied, personnel, the equipment used and working conditions. The main goal is establishment of customer trust in accuracy and precision of laboratory test results. Accredited laboratory has more specific costs than laboratory which is not accredited. To survive on the market, regardless the laboratory is independent or it is a part of a bigger system, the laboratory needs to establish resource management, especially effective cost management. Cost management describes approaches and short-term and long-term management activities, which make value for the customer, according to his known, reported or obligatory requirements and needs. In modern approach, there are different methods for cost calculation. One of them is ABC (Activity-Based Costing method which adds activity costs to products and services trough activities needed for their finalization. In this paper, there is presented improved ABC method for obračun costs, affirmed as activity based cost calculation based on time - TD ABC (Time-Driven Activity-Based Costing. The method uses time as a primary base for costs allocation on products, porudžbine, customers. This is the way for simpler and less expansive getting of information's about costs. This paper describes TD ABC method implemented in accredited Laboratory for physical and chemical testing, which is a part of company Galenika Fitofarmacija a.d. The scope of testing in this laboratory are pesticide materials, meaning technical substances and finished products, within quality control for different internal customers. By using TD ABC method it is possible to define real costs, generated during the laboratory testing, and also effectiveness of specific activities in this process.

  17. Method for Predicting Void Ratio and Triaxial Friction Angle from Laboratory CPT at Shallow Depths

    DEFF Research Database (Denmark)

    Larsen, Kim André; Ibsen, Lars Bo

    In this report an investigation of the relationship between the tip resistance, qc of a laboratory CPT-probe versus the relative density, Dr and friction angle, ∏ of Aalborg University Sand No. 0 is carried out. A method for estimating the relative density and the triaxial friction angle from...... the cone resistance of the laboratory probe is proposed. The suggested method deals with the fact that the friction angle is depended of the stress level especially at low stresses. The method includes a calibration of the cone resistance from the laboratory CPT at shallow depths i.e. low values of d...

  18. Emotional intelligence in medical laboratory science

    Science.gov (United States)

    Price, Travis

    The purpose of this study was to explore the role of emotional intelligence (EI) in medical laboratory science, as perceived by laboratory administrators. To collect and evaluate these perceptions, a survey was developed and distributed to over 1,400 medical laboratory administrators throughout the U.S. during January and February of 2013. In addition to demographic-based questions, the survey contained a list of 16 items, three skills traditionally considered important for successful work in the medical laboratory as well as 13 EI-related items. Laboratory administrators were asked to rate each item for its importance for job performance, their satisfaction with the item's demonstration among currently working medical laboratory scientists (MLS) and the amount of responsibility college-based medical laboratory science programs should assume for the development of each skill or attribute. Participants were also asked about EI training in their laboratories and were given the opportunity to express any thoughts or opinions about EI as it related to medical laboratory science. This study revealed that each EI item, as well as each of the three other items, was considered to be very or extremely important for successful job performance. Administrators conveyed that they were satisfied overall, but indicated room for improvement in all areas, especially those related to EI. Those surveyed emphasized that medical laboratory science programs should continue to carry the bulk of the responsibility for the development of technical skills and theoretical knowledge and expressed support for increased attention to EI concepts at the individual, laboratory, and program levels.

  19. [The historical meaning of serological surveys as a laboratory technology applied to the immunization campaigns. The case of poliomyelitis in Spain].

    Science.gov (United States)

    Ballester, Rosa; Porras, María-Isabel

    2009-01-01

    The aim of the paper is to analyse the introduction, use and diffusion of the serological surveys, a public health technology on the borderline between epidemiology and laboratory, in connection with poliomyelitis in Spain during the Francoism period. Within the framework of the "new history" of medical technologies and innovations, the serological surveys played an important role both in the improvement of knowledge on socio-demographic distribution and the health politics arena.

  20. [Team approaches to critical bleeding (massive bleeding and transfusion) - chairmen's introductory remarks. Questionnaire survey on current status of hospital clinical laboratories evaluating critical hemorrhage].

    Science.gov (United States)

    Kino, Shuichi; Suwabe, Akira

    2014-12-01

    In 2007, "the Guidelines for Actions against Intraoperative Critical Hemorrhage" were established by the Japanese Society of Anaesthesiologists and the Japanese Society of Blood transfusion and Cell Therapy. The documentation of in-hospital procedures for critical hemorrhage, especially about how to select RBC units, has widely standardized hospital practice. Patients with intraoperative critical hemorrhage sometimes suffer from massive blood loss. In this situation, some patients develop coagulopathy. To treat them, we need to evaluate their coagulation status based on laboratory test results. So, we performed a nationwide questionnaire survey on the current status of hospital clinical laboratories evaluating critical hemorrhage. From the results of this survey, it was recommended that central hospital laboratories should try to reduce the turn-around time required to test for coagulation parameters as much as possible for appropriate substitution therapy. (Review).

  1. Environmental survey at Lucas Heights Research Laboratories, 1992

    International Nuclear Information System (INIS)

    Hoffman, E.L.; Loosz, T.

    1994-07-01

    This report summarises the results from the environmental survey during 1992 and assesses the effects of radioactive discharges on both local population and the environment. None of the samples taken from possible human food chains in the vicinity of the Lucas Heights Research Laboratories contained radioactivity which could be attributed to the operation of the site. The data presented din this report clearly shows that the environmental impact of operations at LHRL has been very low. The effective dose to residents living in the immediate neighbourhood of the reactor are very difficult to measure directly but calculated dose estimates are far lower than those due to natural background radiation and medical exposures. Discharges of airborne radioactive gases were within authorised limits when averaged over the year. The dose to the most sensitive members of the public from iodine-131 releases, was -2 mSv/year and the calculated dose from released noble gases to the most exposed individuals was less than 0.01 mSv/year. These figures represent less than one per cent of the limits recommended by the National Health and Medical Research Council of Australia. The monthly average liquid effluent discharge to the Water Board Sewer during 1992 was less than 30 per cent of the permitted level for all periods except May which rose to 62 per cent. For tritium, the concentration was less than 2 per cent of the specified limit. 23 refs., 19 tabs., 5 tabs

  2. [Laboratory diagnosis of genital herpes--direct immunofluorescence method].

    Science.gov (United States)

    Majewska, Anna; Romejko-Wolniewicz, Ewa; Zareba-Szczudlik, Julia; Kilijańczyk, Marek; Gajewska, Małgorzata; Młynarczyk, Grazyna

    2013-07-01

    Aim of the study was to determine clinical usefulness of direct immunofluorescence method in the laboratory diagnosis of genital herpes in women. Overall 187 anogenital swabs were collected from 120 women. Using a dacron-tipped applicator 83 swabs were collected from women suspected of genital herpes and 104 from patients with no signs of genital infection. All samples were tested using cell culture (Vero cell line) and then direct immunofluorescence method (DIF) for the identification of antigens of herpes simplex viruses: HSV-1 and HSV-2. Characteristic cytopathic effect (CPE), indicative of alphaherpesvirus infection, was observed in 43.4% of cultures with clinical specimens collected from women with suspected genital herpes and in 29.8% of cultures of clinical specimens taken from patients with no clinical symptoms of genital herpes. Herpes simplex viruses were determined in 73 samples by direct immunofluorescence method after amplification of the virus in cell culture. The DIF test confirmed the diagnosis based on the microscopic CPE observation in 85%. In 15% of samples (taken from pregnant women without clinical signs of infection) we reported positive immunofluorescence in the absence of CPE. The frequency of antigen detection was statistically significantly higher in samples that were positive by culture study (chi-square test with Yates's correction, p genital herpes in swabs taken from the vestibule of the vagina and the vulva. However, there was no statistically significant difference in the frequency of detection of Herpes Simplex Virus antigens in specimens from different parts of the genital tract in both groups of women (chi-square test, p > 0.05). In our study HHV-1 was the main causative agent of genital herpes. The growing worldwide prevalence of genital herpes, challenges with the clinical diagnosis, and availability of effective antiviral therapy are the main reasons for a growing interest in rapid, proper laboratory diagnosis of infected

  3. Fracture mapping in clays, using gas geochemistry: background, design of a mobile laboratory, and surveys in England and Italy

    International Nuclear Information System (INIS)

    Gregory, R.G.; Duddridge, G.A.

    1991-01-01

    Integrated soil gas analyses for helium, radon, carbon dioxide and oxygen allow the accurate interpretation of soil gas signatures as indicators of underlying structure, due to large variations over faults and fractures. Structures such as these provide channelways for fluid movement in the upper crust. A mobile gas geochemistry laboratory for the analysis of soil gases was constructed and surveys were carried out at sites in England and Italy. At the Down Ampney site, Gloucestershire, gas was injected into a fault plane, and recorded some hours later at the surface. Refinement of this experiment would allow a full characterization of permeable pathways at a site to be made. The soil gas technique has been shown to be viable as an independent site investigation method for the study of fracturing and groundwater movement around potential waste repository sites

  4. Fracture mapping in clays: using gas geochemistry. Background, design of a mobile laboratory and surveys in England and Italy

    International Nuclear Information System (INIS)

    Duddridge, G.A.

    1991-06-01

    Integrated soil gas analyses for helium, radon, carbon dioxide and oxygen allow the accurate interpretation of soil gas signatures as indicators of underlying structure, due to large variations over faults and fractures. Structures such as these provide channelways for fluid movement in the upper crust. A mobile gas geochemistry laboratory for the analysis of soil gases was constructed and surveys were carried out at sites in England and Italy. At the Down Ampney site, Gloucestershire, gas was injected into a fault plane, and recorded some hours later at the surface. Refinement of this experiment would allow a full characterisation of permeable pathways at a site to be made. The soil gas technique has been shown to be viable as an independent site investigation method for the study of fracturing and groundwater movement around potential waste repository sites. (author)

  5. Formerly utilized MED/AEC sites remedial action program post-remedial-action radiological survey of Kent Chemical Laboratory, the University of Chicago, Chicago, IL

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Justus, A.L.; Flynn, K.F.

    1983-05-01

    A comprehensive radiological assessment of Kent Laboratory was conducted during September 1977, by the ANL Radiological Survey Group to determine if any radioactive contamination remained. The results of the assessment indicated the need for remedial action. Since 1977, the University has decontaminated this laboratory building, and in May 1983, the Department of Energy requested the ANL Radiological Survey Group to conduct a post-remedial-action survey. All the contaminated areas identified during the 1977 assessment were rechecked. Contamination remained in six of the rooms. Further decontamination of these areas was conducted by university personnel, and as a result, these areas are now free of contamination. However, a contaminated clay pipe in the attic remained. The clay pipe has since been removed and disposed of as solid radioactive waste. During the post-remedial-action survey, six soil samples were collected from excavation trenches dug in Rooms 1 and 2 as part of the University's remedial action efforts. Also, four sludge samples were taken from below the manhole covers in the basement of Kent Chemical Laboratory to assess the radiological condition of the sewer system. A radiological assessment of the sewer system had not been accomplished during the 1977 survey as per program direction. Radiochemical (fluorometric) and gamma-spectral analyses indicated that eight out of ten soil and sludge samples contained levels of radioactivity above expected background concentrations. The soil has since been further excavated. The building is now free of radioactive contamination in excess of background levels; however, the sewers do contain radioactive materials above background levels since contamination was found at appropriate access points. 6 references, 16 figures, 7 tables

  6. Optimal power flow: a bibliographic survey II. Non-deterministic and hybrid methods

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Stephen [Colorado School of Mines, Department of Electrical Engineering and Computer Science, Golden, CO (United States); Steponavice, Ingrida [Univ. of Jyvaskyla, Dept. of Mathematical Information Technology, Agora (Finland); Rebennack, Steffen [Colorado School of Mines, Division of Economics and Business, Golden, CO (United States)

    2012-09-15

    Over the past half-century, optimal power flow (OPF) has become one of the most important and widely studied nonlinear optimization problems. In general, OPF seeks to optimize the operation of electric power generation, transmission, and distribution networks subject to system constraints and control limits. Within this framework, however, there is an extremely wide variety of OPF formulations and solution methods. Moreover, the nature of OPF continues to evolve due to modern electricity markets and renewable resource integration. In this two-part survey, we survey both the classical and recent OPF literature in order to provide a sound context for the state of the art in OPF formulation and solution methods. The survey contributes a comprehensive discussion of specific optimization techniques that have been applied to OPF, with an emphasis on the advantages, disadvantages, and computational characteristics of each. Part I of the survey provides an introduction and surveys the deterministic optimization methods that have been applied to OPF. Part II of the survey (this article) examines the recent trend towards stochastic, or non-deterministic, search techniques and hybrid methods for OPF. (orig.)

  7. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  8. Does the underground sidewall station survey method meet MHSA ...

    African Journals Online (AJOL)

    The question is asked whether or not this method of sur-veying will meet the MHSA standards of accuracy that was developed for typical hangingwall traverse type networks. Results obtained from a survey closure using a network of clusters of four sidewall stations demonstrates that under the described circumstances it will ...

  9. Results of Surveys for Special Status Reptiles at the Site 300 Facilities of Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Woollett, J J

    2008-09-18

    The purpose of this report is to present the results of a live-trapping and visual surveys for special status reptiles at the Site 300 Facilities of Lawrence Livermore National Laboratory (LLNL). The survey was conducted under the authority of the Federal recovery permit of Swaim Biological Consulting (PRT-815537) and a Memorandum of Understanding issued from the California Department of Fish and Game. Site 300 is located between Livermore and Tracy just north of Tesla road (Alameda County) and Corral Hollow Road (San Joaquin County) and straddles the Alameda and San Joaquin County line (Figures 1 and 2). It encompasses portions of the USGS 7.5 minute Midway and Tracy quadrangles (Figure 2). Focused surveys were conducted for four special status reptiles including the Alameda whipsnake (Masticophis lateralis euryxanthus), the San Joaquin Whipsnake (Masticophis Hagellum ruddock), the silvery legless lizard (Anniella pulchra pulchra), and the California horned lizard (Phrynosoma coronanum frontale).

  10. Survey Shows Variation in Ph.D. Methods Training.

    Science.gov (United States)

    Steeves, Leslie; And Others

    1983-01-01

    Reports on a 1982 survey of journalism graduate studies indicating considerable variation in research methods requirements and emphases in 23 universities offering doctoral degrees in mass communication. (HOD)

  11. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    Science.gov (United States)

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  12. Surveying immigrants without sampling frames - evaluating the success of alternative field methods.

    Science.gov (United States)

    Reichel, David; Morales, Laura

    2017-01-01

    This paper evaluates the sampling methods of an international survey, the Immigrant Citizens Survey, which aimed at surveying immigrants from outside the European Union (EU) in 15 cities in seven EU countries. In five countries, no sample frame was available for the target population. Consequently, alternative ways to obtain a representative sample had to be found. In three countries 'location sampling' was employed, while in two countries traditional methods were used with adaptations to reach the target population. The paper assesses the main methodological challenges of carrying out a survey among a group of immigrants for whom no sampling frame exists. The samples of the survey in these five countries are compared to results of official statistics in order to assess the accuracy of the samples obtained through the different sampling methods. It can be shown that alternative sampling methods can provide meaningful results in terms of core demographic characteristics although some estimates differ to some extent from the census results.

  13. Analytical methods and laboratory facility for the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Dewberry, R.A.; Lethco, A.J.; Denard, C.D.

    1985-01-01

    This paper describes the analytical methods, instruments, and laboratory that will support vitrification of defense waste. The Defense Waste Processing Facility (DWPF) is now being constructed at Savannah River Plant (SRP). Beginning in 1989, SRP high-level defense waste will be immobilized in borosilicate glass for disposal in a federal repository. The DWPF will contain an analytical laboratory for performing process control analyses. Additional analyses will be performed for process history and process diagnostics. The DWPF analytical facility will consist of a large shielded sampling cell, three shielded analytical cells, a laboratory for instrumental analysis and chemical separations, and a counting room. Special instrumentation is being designed for use in the analytical cells, including microwave drying/dissolution apparatus, and remote pipetting devices. The instrumentation laboratory will contain inductively coupled plasma, atomic absorption, Moessbauer spectrometers, a carbon analyzer, and ion chromatography equipment. Counting equipment will include intrinsic germanium detectors, scintillation counters, Phoswich alpha, beta, gamma detectors, and a low-energy photon detector

  14. Method to Increase Undergraduate Laboratory Student Confidence in Performing Independent Research

    Directory of Open Access Journals (Sweden)

    Colton E. Kempton

    2017-05-01

    Full Text Available The goal of an undergraduate laboratory course should be not only to introduce the students to biology methodologies and techniques, but also to teach them independent analytical thinking skills and proper experiment design.  This is especially true for advanced biology laboratory courses that undergraduate students typically take as a junior or senior in college.  Many courses achieve the goal of teaching techniques, but fail to approach the larger goal of teaching critical thinking, experimental design, and student independence.  Here we describe a study examining the application of the scaffolding instructional philosophy in which students are taught molecular techniques with decreasing guidance to force the development of analytical thinking skills and prepare undergraduate students for independent laboratory research. This method was applied to our advanced molecular biology laboratory class and resulted in an increase of confidence among the undergraduate students in their abilities to perform independent research.

  15. An UAV scheduling and planning method for post-disaster survey

    Science.gov (United States)

    Li, G. Q.; Zhou, X. G.; Yin, J.; Xiao, Q. Y.

    2014-11-01

    Annually, the extreme climate and special geological environments lead to frequent natural disasters, e.g., earthquakes, floods, etc. The disasters often bring serious casualties and enormous economic losses. Post-disaster surveying is very important for disaster relief and assessment. As the Unmanned Aerial Vehicle (UAV) remote sensing with the advantage of high efficiency, high precision, high flexibility, and low cost, it is widely used in emergency surveying in recent years. As the UAVs used in emergency surveying cannot stop and wait for the happening of the disaster, when the disaster happens the UAVs usually are working at everywhere. In order to improve the emergency surveying efficiency, it is needed to track the UAVs and assign the emergency surveying task for each selected UAV. Therefore, a UAV tracking and scheduling method for post-disaster survey is presented in this paper. In this method, Global Positioning System (GPS), and GSM network are used to track the UAVs; an emergency tracking UAV information database is built in advance by registration, the database at least includes the following information, e.g., the ID of the UAVs, the communication number of the UAVs; when catastrophe happens, the real time location of all UAVs in the database will be gotten using emergency tracking method at first, then the traffic cost time for all UAVs to the disaster region will be calculated based on the UAVs' the real time location and the road network using the nearest services analysis algorithm; the disaster region is subdivided to several emergency surveying regions based on DEM, area, and the population distribution map; the emergency surveying regions are assigned to the appropriated UAV according to shortest cost time rule. The UAVs tracking and scheduling prototype is implemented using SQLServer2008, ArcEnginge 10.1 SDK, Visual Studio 2010 C#, Android, SMS Modem, and Google Maps API.

  16. Study of nasal swipe analysis methods at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Metcalf, R.A.

    1996-01-01

    The Health Physics Analysis Laboratory (HPAL) performs around 30,000 nasal swipe analyses for transuranic nuclides each year in support of worker health and safety at the Los Alamos National Laboratory (LANL). The analysis method used employs cotton swabs swiped inside a nostril and liquid scintillation analyses of the swabs. The technical basis of this method was developed at LANL and has been in use for over 10 years. Recently, questions regarding the usefulness of a non-homogeneous mixture in liquid scintillation analyses have created a need for re-evaluation of the method. A study of the validity of the method shows it provides reliable, stable, and useful data as an indicator of personnel contamination. The study has also provided insight into the underlying process which occurs to allow the analysis. Further review of this process has shown that similar results can be obtained with different sample matrices, using less material than the current analysis method. This reduction can save HPAL the cost of materials as well as greatly reduce the waste created. Radionuclides of concern include Am-241, Pu-239, and Pu-238

  17. Evaluating Point of Sale Tobacco Marketing Using Behavioral Laboratory Methods

    Science.gov (United States)

    Robinson, Jason D.; Drobes, David J.; Brandon, Thomas H.; Wetter, David W.; Cinciripini, Paul M.

    2018-01-01

    With passage of the 2009 Family Smoking Prevention and Tobacco Control Act, the FDA has authority to regulate tobacco advertising. As bans on traditional advertising venues and promotion of tobacco products have grown, a greater emphasis has been placed on brand exposure and price promotion in displays of products at the point-of-sale (POS). POS marketing seeks to influence attitudes and behavior towards tobacco products using a variety of explicit and implicit messaging approaches. Behavioral laboratory methods have the potential to provide the FDA with a strong scientific base for regulatory actions and a model for testing future manipulations of POS advertisements. We review aspects of POS marketing that potentially influence smoking behavior, including branding, price promotions, health claims, the marketing of emerging tobacco products, and tobacco counter-advertising. We conceptualize how POS marketing potentially influence individual attention, memory, implicit attitudes, and smoking behavior. Finally, we describe specific behavioral laboratory methods that can be adapted to measure the impact of POS marketing on these domains.

  18. Detection and delineation of waste trenches by geophysical methods at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Selfridge, R.J.

    1987-01-01

    Detection and delineation of waste trenches at hazardous waste sites are needed before actual implementation of site corrective measures. In a field study conducted in Solid Waste Storage Area 4 (SWSA4) at Oak Ridge National Laboratory (ORNL), surface geophysical techniques were used to assist in the delineation of waste trenches. A magnetometer/gradiometer survey was used to detect ferrous metals buried at the site. An electromagnetic ground conductivity survey was used to measure the electrical conductivity of the subsurface and aided in supporting the magnetometer/gradiometer results. Results from the two techniques were complimentary and easily integrated into a final interpretation. The reliability, efficiency, and worker safety benefits of these techniques offer a nondestructive surface technique for locating buried waste trenches

  19. A Survey of Formal Methods in Software Development

    DEFF Research Database (Denmark)

    Bjørner, Dines

    2012-01-01

    The use of formal methods and formal techniques in industry is steadily growing. In this survey we shall characterise what we mean by software development and by a formal method; briefly overview a history of formal specification languages - some of which are: VDM (Vienna Development Method, 1974...... need for multi-language formalisation (Petri Nets, MSC, StateChart, Temporal Logics); the sociology of university and industry acceptance of formal methods; the inevitability of the use of formal software development methods; while referring to seminal monographs and textbooks on formal methods....

  20. Survey of electronic payment methods and systems

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Smit, Gerardus Johannes Maria; Helme, A.; Verbraeck, A.

    1996-01-01

    In this paper an overview of electronic payment methods and systems is given. This survey is done as part of the Moby Dick project. Electronic payment systems can be grouped into three broad classes: traditional money transactions, digital currency and creditdebit payments. Such payment systems have

  1. Survey of the diagnostic retooling process in national TB reference laboratories, with special focus on rapid speciation tests endorsed by WHO in 2007.

    Directory of Open Access Journals (Sweden)

    Sanne C van Kampen

    Full Text Available BACKGROUND: Successful integration of new diagnostics in national tuberculosis (TB control programs, also called 'retooling', is highly dependent on operational aspects related to test availability, accessibility and affordability. This survey aimed to find out whether recommendations to use new diagnostics lead to successful retooling in high TB endemic countries, using immunochromatographic tests (ICTs for TB culture speciation as a case study. ICTs are recommended to accurately confirm the presence of bacteria of the Mycobacterium tuberculosis complex in liquid culture isolates. METHODS AND FINDINGS: Questionnaires were sent to national TB reference laboratories (NRLs in 42 high TB endemic countries to address their access to information on ICT implementation, logistics related to availability, accessibility and affordability of ICTs, and testing algorithms. Results from 16 responding countries indicated that half of the NRLs were aware of the contents of WHO guidance documents on liquid culture and ICT implementation, as well as their eligibility for a negotiated pricing agreement for ICT procurement. No major issues with availability and accessibility of ICTs were raised. When asked about testing algorithms, ICTs were not used as stand-alone or first test for TB culture identification as recommended by WHO. CONCLUSIONS: The low response rate was a limitation of this survey and together with NRLs managers' unawareness of global guidance, suggests a lack of effective communication between partners of the global laboratory network and NRLs. TB tests could become more affordable to high TB endemic countries, if the possibility to negotiate lower prices for commercial products is communicated to them more successfully. NRLs need additional guidance to identify where available technologies can be most usefully implemented and in what order, taking into account long-term laboratory strategies.

  2. Humidity requirements in WSCF Laboratories

    International Nuclear Information System (INIS)

    Evans, R.A.

    1994-01-01

    The purpose of this paper is to develop and document a position on Relative Humidity (RH) requirements in the WSCF Laboratories. A current survey of equipment vendors for Organic, Inorganic and Radiochemical laboratories indicate that 25% - 80% relative humidity may meet the environmental requirements for safe operation and protection of all the laboratory equipment

  3. A survey of macromycete diversity at Los Alamos National Laboratory, Bandelier National Monument, and Los Alamos County; A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Jarmie, N.; Rogers, F.J. [Mycology Associates, Los Alamos, NM (United States)

    1997-11-01

    The authors have completed a 5-year survey (1991--1995) of macromycetes found in Los Alamos County, Los Alamos National Laboratory, and Bandelier National Monument. The authors have compiled a database of 1,048 collections, their characteristics, and identifications. The database represents 123 (98%) genera and 175 (73%) species reliably identified. Issues of habitat loss, species extinction, and ecological relationships are addressed, and comparisons with other surveys are made. With this baseline information and modeling of this baseline data, one can begin to understand more about the fungal flora of the area.

  4. Estimating health expectancies from two cross-sectional surveys: The intercensal method

    Directory of Open Access Journals (Sweden)

    Michel Guillot

    2009-10-01

    Full Text Available Health expectancies are key indicators for monitoring the health of populations, as well as for informing debates about compression or expansion of morbidity. However, current methodologies for estimating them are not entirely satisfactory. They are either of limited applicability because of high data requirements (the multistate method or based on questionable assumptions (the Sullivan method. This paper proposes a new method, called the "intercensal" method, which relies on the multistate framework but uses widely available data. The method uses age-specific proportions "healthy" at two successive, independent cross-sectional health surveys, and, together with information on general mortality, solves for the set of transition probabilities that produces the observed sequence of proportions healthy. The system is solved by making realistic parametric assumptions about the age patterns of transition probabilities. Using data from the Health and Retirement Survey (HRS and from the National Health Interview Survey (NHIS, the method is tested against both the multistate method and the Sullivan method. We conclude that the intercensal approach is a promising framework for the indirect estimation of health expectancies.

  5. Competency assessment of microbiology medical laboratory technologists in Ontario, Canada.

    Science.gov (United States)

    Desjardins, Marc; Fleming, Christine Ann

    2014-08-01

    Accreditation in Ontario, Canada, requires that licensed clinical laboratories participate in external quality assessment (also known as proficiency testing) and perform competency evaluation of their staff. To assess the extent of ongoing competency assessment practices, the Quality Management Program--Laboratory Services (QMP-LS) Microbiology Committee surveyed all 112 licensed Ontario microbiology laboratories. The questionnaire consisted of a total of 21 questions that included yes/no, multiple-choice, and short-answer formats. Participants were asked to provide information about existing programs, the frequency of testing, what areas are evaluated, and how results are communicated to the staff. Of the 111 responding laboratories, 6 indicated they did not have a formal evaluation program since they perform only limited bacteriology testing. Of the remaining 105 respondents, 87% perform evaluations at least annually or every 2 years, and 61% include any test or task performed, whereas 16% and 10% focus only on problem areas and high-volume complex tasks, respectively. The most common methods of evaluation were review of external quality assessment (EQA) challenges, direct observation, and worksheet review. With the exception of one participant, all communicate results to staff, and most take remedial action to correct the deficiencies. Although most accredited laboratories have a program to assess the ongoing competency of their staff, the methods used are not standardized or consistently applied, indicating that there is room for improvement. The survey successfully highlighted potential areas for improvement and allowed the QMP-LS Microbiology Committee to provide guidance to Ontario laboratories for establishing or improving existing microbiology-specific competency assessment programs. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  6. An Analysis of Laboratory Safety in Texas.

    Science.gov (United States)

    Fuller, Edward J.; Picucci, Ali Callicoatte; Collins, James W.; Swann, Philip

    This paper reports on a survey to discover the types of laboratory accidents that occur in Texas public schools, the factors associated with such accidents, and the practices of schools with regard to current laboratory safety requirements. The purpose of the survey is to better understand safety conditions in Texas public schools and to help…

  7. Barriers and facilitators to reducing frequent laboratory testing for patients who are stable on warfarin: a mixed methods study of de-implementation in five anticoagulation clinics.

    Science.gov (United States)

    Barnes, Geoffrey D; Misirliyan, Sevan; Kaatz, Scott; Jackson, Elizabeth A; Haymart, Brian; Kline-Rogers, Eva; Kozlowski, Jay; Krol, Gregory; Froehlich, James B; Sales, Anne

    2017-07-14

    Patients on chronic warfarin therapy require regular laboratory monitoring to safely manage warfarin. Recent studies have challenged the need for routine monthly blood draws in the most stable warfarin-treated patients, suggesting the safety of less frequent laboratory testing (up to every 12 weeks). De-implementation efforts aim to reduce the use of low-value clinical practices. To explore barriers and facilitators of a de-implementation effort to reduce the use of frequent laboratory tests for patients with stable warfarin management in nurse/pharmacist-run anticoagulation clinics, we performed a mixed-methods study conducted within a state-wide collaborative quality improvement collaborative. Using a mixed-methods approach, we conducted post-implementation semi-structured interviews with a total of eight anticoagulation nurse or pharmacist staff members at five participating clinic sites to assess barriers and facilitators to de-implementing frequent international normalized ratio (INR) laboratory testing among patients with stable warfarin control. Interview guides were based on the Tailored Implementation for Chronic Disease (TICD) framework. Informed by interview themes, a survey was developed and administered to all anticoagulation clinical staff (n = 62) about their self-reported utilization of less frequent INR testing and specific barriers to de-implementing the standard (more frequent) INR testing practice. From the interviews, four themes emerged congruent with TICD domains: (1) staff overestimating their actual use of less frequent INR testing (individual health professional factors), (2) barriers to appropriate patient engagement (incentives and resources), (3) broad support for an electronic medical record flag to identify potentially eligible patients (incentives and resources), and (4) the importance of personalized nurse/pharmacist feedback (individual health professional factors). In the survey (65% response rate), staff report offering less

  8. Verification Survey of the Building 315 Zero Power Reactor-6 Facility, Argonne National Laboratory-East, Argonne, Illinois

    International Nuclear Information System (INIS)

    W. C. Adams

    2007-01-01

    Oak Ridge Institute for Science and Education (ORISE) conducted independent verification radiological survey activities at Argonne National Laboratory's Building 315, Zero Power Reactor-6 facility in Argonne, Illinois. Independent verification survey activities included document and data reviews, alpha plus beta and gamma surface scans, alpha and beta surface activity measurements, and instrumentation comparisons. An interim letter report and a draft report, documenting the verification survey findings, were submitted to the DOE on November 8, 2006 and February 22, 2007, respectively (ORISE 2006b and 2007). Argonne National Laboratory-East (ANL-E) is owned by the U.S. Department of Energy (DOE) and is operated under a contract with the University of Chicago. Fundamental and applied research in the physical, biomedical, and environmental sciences are conducted at ANL-E and the laboratory serves as a major center of energy research and development. Building 315, which was completed in 1962, contained two cells, Cells 5 and 4, for holding Zero Power Reactor (ZPR)-6 and ZPR-9, respectively. These reactors were built to increase the knowledge and understanding of fast reactor technology. ZPR-6 was also referred to as the Fast Critical Facility and focused on fast reactor studies for civilian power production. ZPR-9 was used for nuclear rocket and fast reactor studies. In 1967, the reactors were converted for plutonium use. The reactors operated from the mid-1960's until 1982 when they were both shut down. Low levels of radioactivity were expected to be present due to the operating power levels of the ZPR's being restricted to well below 1,000 watts. To evaluate the presence of radiological contamination, DOE characterized the ZPRs in 2001. Currently, the Melt Attack and Coolability Experiments (MACE) and Melt Coolability and Concrete Interaction (MCCI) Experiments are being conducted in Cell 4 where the ZPR-9 is located (ANL 2002 and 2006). ANL has performed final

  9. Environmental Survey preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    1988-04-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Sandia National Laboratories conducted August 17 through September 4, 1987. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with Sandia National Laboratories-Albuquerque (SNLA). The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at SNLA, and interviews with site personnel. 85 refs., 49 figs., 48 tabs.

  10. Field methods and quality-assurance plan for water-quality activities and water-level measurements, U.S. Geological Survey, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Bartholomay, Roy C.; Maimer, Neil V.; Wehnke, Amy J.

    2014-01-01

    Water-quality activities and water-level measurements by the personnel of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation’s water resources. The activities are carried out in cooperation with the U.S. Department of Energy (DOE) Idaho Operations Office. Results of the water-quality and hydraulic head investigations are presented in various USGS publications or in refereed scientific journals and the data are stored in the National Water Information System (NWIS) database. The results of the studies are used by researchers, regulatory and managerial agencies, and interested civic groups. In the broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the “state-of-the-art” technology, and quality assurance ensures that quality control is maintained within specified limits.

  11. Survey of diagnostic and typing capacity for Clostridium difficile infection in Europe, 2011 and 2014.

    Science.gov (United States)

    van Dorp, Sofie M; Notermans, Daan W; Alblas, Jeroen; Gastmeier, Petra; Mentula, Silja; Nagy, Elisabeth; Spigaglia, Patrizia; Ivanova, Katiusha; Fitzpatrick, Fidelma; Barbut, Frédéric; Morris, Trefor; Wilcox, Mark H; Kinross, Pete; Suetens, Carl; Kuijper, Ed J

    2016-07-21

    Suboptimal laboratory diagnostics for Clostridium difficile infection (CDI) impedes its surveillance and control across Europe. We evaluated changes in local laboratory CDI diagnostics and changes in national diagnostic and typing capacity for CDI during the European C. difficile Infection Surveillance Network (ECDIS-Net) project, through cross-sectional surveys in 33 European countries in 2011 and 2014. In 2011, 126 (61%) of a convenience sample of 206 laboratories in 31 countries completed a survey on local diagnostics. In 2014, 84 (67%) of these 126 laboratories in 26 countries completed a follow-up survey. Among laboratories that participated in both surveys, use of CDI diagnostics deemed 'optimal' or 'acceptable' increased from 19% to 46% and from 10% to 15%, respectively (p  difficile typing method increased from 22/31 countries in 2011 to 26/32 countries in 2014; for PCR ribotyping from 20/31 countries to 23/32 countries, and specifically for capillary PCR ribotyping from 7/31 countries to 16/32 countries. While our study indicates improved diagnostic capability and national capacity for capillary PCR ribotyping across European laboratories between 2011 and 2014, increased use of 'optimal' diagnostics should be promoted. This article is copyright of The Authors, 2016.

  12. Internal Quality Control Practices in Coagulation Laboratories: recommendations based on a patterns-of-practice survey.

    Science.gov (United States)

    McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R

    2015-12-01

    Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.

  13. Intensive archaeological survey of the proposed Savannah River Ecology Laboratory Conference Center and Educational Facility, Savannah River Site, Aiken County, South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, K.; Crass, D.C.; Sassaman, K.E.

    1993-02-01

    Documented in this report are the methods and results of an intensive archaeological survey for the proposed University of Georgia Savannah River Ecology Laboratory (SREL) Conference Center and Educational Facility on the DOE Savannah River Site (SRS). Archaeological investigations conducted by the Savannah River Archaeological Research Program (SRARP) on the 70-acre project area and associated rights-of-way consisted of subsurface testing at two previously recorded sites and the discovery of one previously unrecorded site. The results show that 2 sites contain archaeological remains that may yield significant information about human occupations in the Aiken Plateau and are therefore considered eligible for nomination to the National Register of Historic Places. Adverse impacts to these sites can be mitigated through avoidance.

  14. Comparing two survey methods for estimating maternal and perinatal mortality in rural Cambodia.

    Science.gov (United States)

    Chandy, Hoeuy; Heng, Yang Van; Samol, Ha; Husum, Hans

    2008-03-01

    We need solid estimates of maternal mortality rates (MMR) to monitor the impact of maternal care programs. Cambodian health authorities and WHO report the MMR in Cambodia at 450 per 100,000 live births. The figure is drawn from surveys where information is obtained by interviewing respondents about the survival of all their adult sisters (sisterhood method). The estimate is statistically imprecise, 95% confidence intervals ranging from 260 to 620/100,000. The MMR estimate is also uncertain due to under-reporting; where 80-90% of women deliver at home maternal fatalities may go undetected especially where mortality is highest, in remote rural areas. The aim of this study was to attain more reliable MMR estimates by using survey methods other than the sisterhood method prior to an intervention targeting obstetric rural emergencies. The study was carried out in rural Northwestern Cambodia where access to health services is poor and poverty, endemic diseases, and land mines are endemic. Two survey methods were applied in two separate sectors: a community-based survey gathering data from public sources and a household survey gathering data direct from primary sources. There was no statistically significant difference between the two survey results for maternal deaths, both types of survey reported mortality rates around the public figure. The household survey reported a significantly higher perinatal mortality rate as compared to the community-based survey, 8.6% versus 5.0%. Also the household survey gave qualitative data important for a better understanding of the many problems faced by mothers giving birth in the remote villages. There are detection failures in both surveys; the failure rate may be as high as 30-40%. PRINCIPLE CONCLUSION: Both survey methods are inaccurate, therefore inappropriate for evaluation of short-term changes of mortality rates. Surveys based on primary informants yield qualitative information about mothers' hardships important for the design

  15. MEDICO-LABORATORY SERVICES IN OUTPATIENT CARE IN NORTHEASTERN BULGARIA – STATE AND PROSPECTS

    Directory of Open Access Journals (Sweden)

    Emilia P. Georgieva

    2017-11-01

    Full Text Available Aim: The aim of this article is to study the satisfaction of patients with laboratory services in outpatient care in Northeastern Bulgaria regarding access and quality of service. Study design: Prospective cohort study Material and methods: The survey was carried out on the territory of Northeastern Bulgaria and covered the districts of Varna, Dobrich and Shumen and thirty municipalities. The following methods were applied in the study: sociological method by applied direct anonymous questionnaire, documentary method and statistical methods for analysis and interpretation of the data in order to reveal the nature of the observed phenomena and their interrelations. Results: The research data show that 24,4% of the respondents live at a distance of more than ten kilometres from the nearest medico-diagnostic laboratory. The larger share of these patients are residents of small settlements in Northeastern Bulgaria. More than half (55% of the respondents are not satisfied with their provision of laboratory services, but the majority of patients claim that the location of the selected laboratory is accessible (69,4% and the quality of the laboratory service is high (83,7%. Conclusion: The main problems in outpatient care are related to the poor provision of medico-laboratory services and specialized outpatient care in the smaller settlements in Northeastern Bulgaria.

  16. Quality assurance in medical laboratories

    International Nuclear Information System (INIS)

    Boroviczeny, K.G. von; Merten, R.; Merten, U.P.

    1987-01-01

    The book presents a comprehensive and specified survey of the quality assurance measures and methods applied in medical laboratories in the pre-analytical phase and in the analytical and post-analytical phases. It also gives information on computer-aided procedures, cost-benefit analyses in this field, and on official requirements and standards in the fields of clinical chemistry, hematology, immunology and microbiology, and equipment testing and inspection. One chapter of the book particularly deals with quality assurance for radioimmunological in-vitro analyses. With 112 figs., 337 tabs [de

  17. Evaluation of methods to calibrate radiation survey meters

    International Nuclear Information System (INIS)

    Robinson, R.C.; Arbeau, N.D.

    1987-04-01

    Calibration requirements for radiation survey meters used in industrial radiography have been reviewed. Information obtained from a literature search, discussions with CSLD inspectors and firms performing calibrations has been considered. Based on this review a set of minimum calibration requirements was generated which, when met, will determine that the survey meter is suited for measurements described in the current AEC Regulations that apply to industrial radiography equipment. These requirements are presented in this report and may be used as guidelines for evaluating calibration methods proposed or in use in industry. 39 refs

  18. Radiological survey support activities for the decommissioning of the Ames Laboratory Research Reactor Facility, Ames, Iowa

    Energy Technology Data Exchange (ETDEWEB)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Justus, A.L.; Flynn, K.F.

    1984-09-01

    At the request of the Engineering Support Division of the US Department of Energy-Chicago Operations Office and in accordance with the programmatic overview/certification responsibilities of the Department of Energy Environmental and Safety Engineering Division, the Argonne National Laboratory Radiological Survey Group conducted a series of radiological measurements and tests at the Ames Laboratory Research Reactor located in Ames, Iowa. These measurements and tests were conducted during 1980 and 1981 while the reactor building was being decontaminated and decommissioned for the purpose of returning the building to general use. The results of these evaluations are included in this report. Although the surface contamination within the reactor building could presumably be reduced to negligible levels, the potential for airborne contamination from tritiated water vapor remains. This vapor emmanates from contamination within the concrete of the building and should be monitored until such time as it is reduced to background levels. 2 references, 8 figures, 6 tables.

  19. U.S. Ebola Treatment Center Clinical Laboratory Support.

    Science.gov (United States)

    Jelden, Katelyn C; Iwen, Peter C; Herstein, Jocelyn J; Biddinger, Paul D; Kraft, Colleen S; Saiman, Lisa; Smith, Philip W; Hewlett, Angela L; Gibbs, Shawn G; Lowe, John J

    2016-04-01

    Fifty-five hospitals in the United States have been designated Ebola treatment centers (ETCs) by their state and local health authorities. Designated ETCs must have appropriate plans to manage a patient with confirmed Ebola virus disease (EVD) for the full duration of illness and must have these plans assessed through a CDC site visit conducted by an interdisciplinary team of subject matter experts. This study determined the clinical laboratory capabilities of these ETCs. ETCs were electronically surveyed on clinical laboratory characteristics. Survey responses were returned from 47 ETCs (85%). Forty-one (87%) of the ETCs planned to provide some laboratory support (e.g., point-of-care [POC] testing) within the room of the isolated patient. Forty-four (94%) ETCs indicated that their hospital would also provide clinical laboratory support for patient care. Twenty-two (50%) of these ETC clinical laboratories had biosafety level 3 (BSL-3) containment. Of all respondents, 34 (72%) were supported by their jurisdictional public health laboratory (PHL), all of which had available BSL-3 laboratories. Overall, 40 of 44 (91%) ETCs reported BSL-3 laboratory support via their clinical laboratory and/or PHL. This survey provided a snapshot of the laboratory support for designated U.S. ETCs. ETCs have approached high-level isolation critical care with laboratory support in close proximity to the patient room and by distributing laboratory support among laboratory resources. Experts might review safety considerations for these laboratory testing/diagnostic activities that are novel in the context of biocontainment care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. Experimental methods for laboratory-scale ensilage of lignocellulosic biomass

    International Nuclear Information System (INIS)

    Tanjore, Deepti; Richard, Tom L.; Marshall, Megan N.

    2012-01-01

    Anaerobic fermentation is a potential storage method for lignocellulosic biomass in biofuel production processes. Since biomass is seasonally harvested, stocks are often dried or frozen at laboratory scale prior to fermentation experiments. Such treatments prior to fermentation studies cause irreversible changes in the plant cells, influencing the initial state of biomass and thereby the progression of the fermentation processes itself. This study investigated the effects of drying, refrigeration, and freezing relative to freshly harvested corn stover in lab-scale ensilage studies. Particle sizes, as well as post-ensilage drying temperatures for compositional analysis, were tested to identify the appropriate sample processing methods. After 21 days of ensilage the lowest pH value (3.73 ± 0.03), lowest dry matter loss (4.28 ± 0.26 g. 100 g-1DM), and highest water soluble carbohydrate (WSC) concentrations (7.73 ± 0.26 g. 100 g-1DM) were observed in control biomass (stover ensiled within 12 h of harvest without any treatments). WSC concentration was significantly reduced in samples refrigerated for 7 days prior to ensilage (3.86 ± 0.49 g. 100 g −1 DM). However, biomass frozen prior to ensilage produced statistically similar results to the fresh biomass control, especially in treatments with cell wall degrading enzymes. Grinding to decrease particle size reduced the variance amongst replicates for pH values of individual reactors to a minor extent. Drying biomass prior to extraction of WSCs resulted in degradation of the carbohydrates and a reduced estimate of their concentrations. The methods developed in this study can be used to improve ensilage experiments and thereby help in developing ensilage as a storage method for biofuel production. -- Highlights: ► Laboratory-scale methods to assess the influence of ensilage biofuel production. ► Drying, freezing, and refrigeration of biomass influenced microbial fermentation. ► Freshly ensiled stover exhibited

  1. An easy, rapid and inexpensive method to monitor tributyltin (TBT) toxicity in the laboratory.

    Science.gov (United States)

    Cruz, Andreia; Moreira, Rafael; Mendo, Sónia

    2014-05-01

    Tributyltin (TBT) contamination remains a major problem worldwide. Many laboratories are committed to the development of remediation methodologies that could help reduce the negative impact of this compound in the environment. Furthermore, it is important to have at hand simple methodologies for evaluating TBT toxicity in the laboratory, besides the use of complex and costly analytical instrumentation. With that purpose, a method was adapted that is based on the inhibition of growth of an indicator strain, Micrococcus luteus ATCC 9341, under TBT. Different types of matrices, of TBT concentrations and sample treatments were tested. The results herein reported show that the bioassay method can be applied for both aqueous and soil samples and also for a high range of TBT concentrations (at least up to 500 μmol/L). Besides being cheap and easy to perform, it can be performed in any laboratory. Additionally, one possible application of the method to monitor TBT degradation is presented as an example.

  2. Methods of Estimation the Reliability and Increasing the Informativeness of the Laboratory Results (Analysis of the Laboratory Case of Measurement the Indicators of Thyroid Function

    Directory of Open Access Journals (Sweden)

    N A Kovyazina

    2014-06-01

    Full Text Available The goal of the study was to demonstrate the multilevel laboratory quality management system and point at the methods of estimating the reliability and increasing the amount of information content of the laboratory results (on the example of the laboratory case. Results. The article examines the stages of laboratory quality management which has helped to estimate the reliability of the results of determining Free T3, Free T4 and TSH. The measurement results are presented by the expanded uncertainty and the evaluation of the dynamics. Conclusion. Compliance with mandatory measures for laboratory quality management system enables laboratories to obtain reliable results and calculate the parameters that are able to increase the amount of information content of laboratory tests in clinical decision making.

  3. SRC-I demonstration plant analytical laboratory methods manual. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.; Skinner, R.W.; Znaimer, S.

    1983-03-01

    This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.

  4. Methods of Estimation the Reliability and Increasing the Informativeness of the Laboratory Results (Analysis of the Laboratory Case of Measurement the Indicators of Thyroid Function)

    OpenAIRE

    N A Kovyazina; N A Alhutova; N N Zybina; N M Kalinina

    2014-01-01

    The goal of the study was to demonstrate the multilevel laboratory quality management system and point at the methods of estimating the reliability and increasing the amount of information content of the laboratory results (on the example of the laboratory case). Results. The article examines the stages of laboratory quality management which has helped to estimate the reliability of the results of determining Free T3, Free T4 and TSH. The measurement results are presented by the expanded unce...

  5. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    Science.gov (United States)

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  6. The Jamaica asthma and allergies national prevalence survey: rationale and methods

    Directory of Open Access Journals (Sweden)

    Edwards Nancy C

    2010-04-01

    Full Text Available Abstract Background Asthma is a significant public health problem in the Caribbean. Prevalence surveys using standardized measures of asthma provide valid prevalence estimates to facilitate regional and international comparisons and monitoring of trends. This paper describes methods used in the Jamaica Asthma and Allergies National Prevalence Survey, challenges associated with this survey and strategies used to overcome these challenges. Methods/Design An island wide, cross-sectional, community-based survey of asthma, asthma symptoms and allergies was done among adults and children using the European Community Respiratory Health Survey Questionnaire for adults and the International Study of Asthma and Allergies in Children. Stratified multi-stage cluster sampling was used to select 2, 163 adults aged 18 years and older and 2, 017 children aged 2-17 years for the survey. The Kish selection table was used to select one adult and one child per household. Data analysis accounted for sampling design and prevalence estimates were weighted to produce national estimates. Discussion The Jamaica Asthma and Allergies National Prevalence Survey is the first population- based survey in the Caribbean to determine the prevalence of asthma and allergies both in adults and children using standardized methods. With response rates exceeding 80% in both groups, this approach facilitated cost-effective gathering of high quality asthma prevalence data that will facilitate international and regional comparison and monitoring of asthma prevalence trends. Another unique feature of this study was the partnership with the Ministry of Health in Jamaica, which ensured the collection of data relevant for decision-making to facilitate the uptake of research evidence. The findings of this study will provide important data on the burden of asthma and allergies in Jamaica and contribute to evidence-informed planning of comprehensive asthma management and education programs.

  7. The IMACS Cluster Building Survey. I. Description of the Survey and Analysis Methods

    Science.gov (United States)

    Oemler Jr., Augustus; Dressler, Alan; Gladders, Michael G.; Rigby, Jane R.; Bai, Lei; Kelson, Daniel; Villanueva, Edward; Fritz, Jacopo; Rieke, George; Poggianti, Bianca M.; hide

    2013-01-01

    The IMACS Cluster Building Survey uses the wide field spectroscopic capabilities of the IMACS spectrograph on the 6.5 m Baade Telescope to survey the large-scale environment surrounding rich intermediate-redshift clusters of galaxies. The goal is to understand the processes which may be transforming star-forming field galaxies into quiescent cluster members as groups and individual galaxies fall into the cluster from the surrounding supercluster. This first paper describes the survey: the data taking and reduction methods. We provide new calibrations of star formation rates (SFRs) derived from optical and infrared spectroscopy and photometry. We demonstrate that there is a tight relation between the observed SFR per unit B luminosity, and the ratio of the extinctions of the stellar continuum and the optical emission lines.With this, we can obtain accurate extinction-corrected colors of galaxies. Using these colors as well as other spectral measures, we determine new criteria for the existence of ongoing and recent starbursts in galaxies.

  8. THE IMACS CLUSTER BUILDING SURVEY. I. DESCRIPTION OF THE SURVEY AND ANALYSIS METHODS

    Energy Technology Data Exchange (ETDEWEB)

    Oemler, Augustus Jr.; Dressler, Alan; Kelson, Daniel; Villanueva, Edward [Observatories of the Carnegie Institution for Science, 813 Santa Barbara St., Pasadena, CA 91101-1292 (United States); Gladders, Michael G. [Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL 60637 (United States); Rigby, Jane R. [Observational Cosmology Lab, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Bai Lei [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); Fritz, Jacopo [Sterrenkundig Observatorium, Universiteit Gent, Krijgslaan 281 S9, B-9000 Gent (Belgium); Rieke, George [Steward Observatory, University of Arizona, Tucson, AZ 8572 (United States); Poggianti, Bianca M.; Vulcani, Benedetta, E-mail: oemler@obs.carnegiescience.edu [INAF-Osservatorio Astronomico di Padova, Vicolo dell' Osservatorio 5, I-35122 Padova (Italy)

    2013-06-10

    The IMACS Cluster Building Survey uses the wide field spectroscopic capabilities of the IMACS spectrograph on the 6.5 m Baade Telescope to survey the large-scale environment surrounding rich intermediate-redshift clusters of galaxies. The goal is to understand the processes which may be transforming star-forming field galaxies into quiescent cluster members as groups and individual galaxies fall into the cluster from the surrounding supercluster. This first paper describes the survey: the data taking and reduction methods. We provide new calibrations of star formation rates (SFRs) derived from optical and infrared spectroscopy and photometry. We demonstrate that there is a tight relation between the observed SFR per unit B luminosity, and the ratio of the extinctions of the stellar continuum and the optical emission lines. With this, we can obtain accurate extinction-corrected colors of galaxies. Using these colors as well as other spectral measures, we determine new criteria for the existence of ongoing and recent starbursts in galaxies.

  9. A multispectral scanner survey of the Idaho National Engineering Laboratory and the Hanford Reservation

    International Nuclear Information System (INIS)

    Brewster, S.B. Jr.; Howard, M.E.; Shines, J.E.

    1994-09-01

    An airborne multispectral scanner survey of selected sites on the Idaho National Engineering Laboratory and the Hanford Reservation was performed in mid-November 1993. Aerial multispectral scanner and photography data were acquired coincidentally with the Big O experiment at both locations. To illustrate two potential applications, the multispectral scanner data were digitally enhanced to facilitate the detection of soil disturbance and evidence of surface water transport. The main conclusion of this study was that multispectral data acquired under these conditions can be useful for soil disturbance detection. The imagery did not prove as useful, however, for direct indications of surface water transport. It was possible to infer some water transport patterns from dry water beds, but only if surface indications were present

  10. Sample size methods for estimating HIV incidence from cross-sectional surveys.

    Science.gov (United States)

    Konikoff, Jacob; Brookmeyer, Ron

    2015-12-01

    Understanding HIV incidence, the rate at which new infections occur in populations, is critical for tracking and surveillance of the epidemic. In this article, we derive methods for determining sample sizes for cross-sectional surveys to estimate incidence with sufficient precision. We further show how to specify sample sizes for two successive cross-sectional surveys to detect changes in incidence with adequate power. In these surveys biomarkers such as CD4 cell count, viral load, and recently developed serological assays are used to determine which individuals are in an early disease stage of infection. The total number of individuals in this stage, divided by the number of people who are uninfected, is used to approximate the incidence rate. Our methods account for uncertainty in the durations of time spent in the biomarker defined early disease stage. We find that failure to account for this uncertainty when designing surveys can lead to imprecise estimates of incidence and underpowered studies. We evaluated our sample size methods in simulations and found that they performed well in a variety of underlying epidemics. Code for implementing our methods in R is available with this article at the Biometrics website on Wiley Online Library. © 2015, The International Biometric Society.

  11. Practical methods for radiation survey in nuclear installations

    International Nuclear Information System (INIS)

    Shweikani, R.

    2001-12-01

    This study is placed to those who are responsible to perform radiation survey in the nuclear installations, especially the beginners. Therefore, it gives a comprehensive view to all-important aspects related to their work starting from the structure of atoms to the practical steps for radiation survey works. So, it clarify how to perform personal monitoring, methods for monitoring surface contamination, methods for measuring radioactivity of gases and radioactive aerosols in air, monitoring radiation doses, measuring radiation influences in workplaces and finally measuring internal exposure of radiation workers in nuclear installations. Finally, The study shows some cases of breaches of radiation protection rules in some American nuclear installations and describes the final results of these breaches. The aim of this is to assure that any breach or ignore to radiation protection principles may produce bad results, and there is no leniency in implementing environmental radiation protection principles. (author)

  12. A close-up on laboratory visitors

    CERN Multimedia

    2004-01-01

    "Inside the Big Black Box" is a European survey of responses by visitors to five laboratories, including CERN. Its findings will be presented at a two-day meeting to be held at CERN on 29 and 30 March. Can the visits programme of a research laboratory, such as a particle physics laboratory, satisfy the public's curiosity? What are the impressions of visitors to such laboratories? "Inside the Big Black Box" (IN3B), a study sponsored by the European Commission, provides the answers to these previously unanswered questions. The results of this survey, conducted among 4000 visitors to five laboratories (CERN in Switzerland, LNGS in Italy, Demokritos in Greece and DESY and Forschungszentrum Jülich in Germany), will be presented at a meeting hosted by CERN on 29 and 30 March. The detailed programme and a registration form for those wishing to attend can be found at: http://www.cern.ch/info/IN3B. Visitors to the DESY laboratory inside the hall of the TESLA (Tera Electr...

  13. Principles of Single-Laboratory Validation of Analytical Methods for Testing the Chemical Composition of Pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Ambrus, A. [Hungarian Food Safety Office, Budapest (Hungary)

    2009-07-15

    Underlying theoretical and practical approaches towards pesticide formulation analysis are discussed, i.e. general principles, performance characteristics, applicability of validation data, verification of method performance, and adaptation of validated methods by other laboratories. The principles of single laboratory validation of analytical methods for testing the chemical composition of pesticides are outlined. Also the theoretical background is described for performing pesticide formulation analysis as outlined in ISO, CIPAC/AOAC and IUPAC guidelines, including methodological characteristics such as specificity, selectivity, linearity, accuracy, trueness, precision and bias. Appendices I–III hereof give practical and elaborated examples on how to use the Horwitz approach and formulae for estimating the target standard deviation towards acceptable analytical repeatability. The estimation of trueness and the establishment of typical within-laboratory reproducibility are treated in greater detail by means of worked-out examples. (author)

  14. A Biosecurity Survey in Kenya, November 2014 to February 2015.

    Science.gov (United States)

    Ndhine, Edwardina Otieno; Slotved, Hans-Christian; Osoro, Eric Mogaka; Olsen, Katja N; Rugutt, Moses; Wanjohi, Cathryn W; Mwanda, Walter; Kinyagia, Benson Mburu; Steenhard, Nina R; Hansen, John-Erik Stig

    2016-01-01

    A biosecurity survey was performed to gather information on the biosecurity level and laboratory capacity in Kenya for the purpose of providing information outlining relevant components for biosecurity legislation, biosecurity implementation, and enforcement of biosecurity measures in Kenya. This survey is, to the authors' knowledge, the first to be published from an African country. A total of 86 facilities with laboratories covering relevant categories, such as training laboratories, human diagnostic laboratories, veterinary diagnostic laboratories, and research laboratories, were selected to participate in the survey. Each facility was visited by a survey team and staff were asked to answer 29 groups of questions from a questionnaire. The survey showed that Kenyan laboratory facilities contain biological agents of biosecurity concern. The restrictions for these agents were found to be limited for several of the facilities, in that many laboratory facilities and storage units were open for access by either students or staff who had no need of access to the laboratory. The survey showed a great deal of confusion in the terms biosecurity and biosafety and a generally limited biosecurity awareness among laboratory personnel. The survey showed that the security of biological agents of biosecurity concern in many facilities does not meet the international requirements. The authors recommend developing a legal framework in Kenya for effective controls, including national biosecurity regulations, guidelines, and procedures, thereby reducing the risk that a Kenyan laboratory would be the source of a future biological attack.

  15. Survey Method for Radiological Surveys of 300-FF-1 Operable Unit Soils and Material

    International Nuclear Information System (INIS)

    Brehm, D.M.

    1998-06-01

    This technical basis is to be used to survey soils at the 300-FF-1 Operable Unit during remediation of the site. Its purpose is to provide a basis for the survey methods to be employed by radiological control technician (RCTs) to guide the excavation effort in accordance with the 300-FF-1 waste site Record of Decision (ROD). The ROD for the 300-FF-1 Operable Unit requires selective excavation, removal, and disposal of contaminated soil above 350 pCi/g total uranium activity. Soil above this level will be disposed of as radioactive waste. The remaining soil will remain onsite

  16. Accelerator and transport line survey and alignment

    International Nuclear Information System (INIS)

    Ruland, R.E.

    1991-10-01

    This paper summarizes the survey and alignment processes of accelerators and transport lines and discusses the propagation of errors associated with these processes. The major geodetic principles governing the survey and alignment measurement space are introduced and their relationship to a lattice coordinate system shown. The paper continues with a broad overview about the activities involved in the step sequence from initial absolute alignment to final smoothing. Emphasis is given to the relative alignment of components, in particular to the importance of incorporating methods to remove residual systematic effects in surveying and alignment operations. Various approaches to smoothing used at major laboratories are discussed. 47 refs., 19 figs., 1 tab

  17. Inter-laboratory validation of an inexpensive streamlined method to measure inorganic arsenic in rice grain.

    Science.gov (United States)

    Chaney, Rufus L; Green, Carrie E; Lehotay, Steven J

    2018-05-04

    With the establishment by CODEX of a 200 ng/g limit of inorganic arsenic (iAs) in polished rice grain, more analyses of iAs will be necessary to ensure compliance in regulatory and trade applications, to assess quality control in commercial rice production, and to conduct research involving iAs in rice crops. Although analytical methods using high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) have been demonstrated for full speciation of As, this expensive and time-consuming approach is excessive when regulations are based only on iAs. We report a streamlined sample preparation and analysis of iAs in powdered rice based on heated extraction with 0.28 M HNO 3 followed by hydride generation (HG) under control of acidity and other simple conditions. Analysis of iAs is then conducted using flow-injection HG and inexpensive ICP-atomic emission spectroscopy (AES) or other detection means. A key innovation compared with previous methods was to increase the acidity of the reagent solution with 4 M HCl (prior to reduction of As 5+ to As 3+ ), which minimized interferences from dimethylarsinic acid. An inter-laboratory method validation was conducted among 12 laboratories worldwide in the analysis of six shared blind duplicates and a NIST Standard Reference Material involving different types of rice and iAs levels. Also, four laboratories used the standard HPLC-ICP-MS method to analyze the samples. The results between the methods were not significantly different, and the Horwitz ratio averaged 0.52 for the new method, which meets official method validation criteria. Thus, the simpler, more versatile, and less expensive method may be used by laboratories for several purposes to accurately determine iAs in rice grain. Graphical abstract Comparison of iAs results from new and FDA methods.

  18. Validation of a laboratory method for evaluating dynamic properties of reconstructed equine racetrack surfaces.

    Directory of Open Access Journals (Sweden)

    Jacob J Setterbo

    Full Text Available Racetrack surface is a risk factor for racehorse injuries and fatalities. Current research indicates that race surface mechanical properties may be influenced by material composition, moisture content, temperature, and maintenance. Race surface mechanical testing in a controlled laboratory setting would allow for objective evaluation of dynamic properties of surface and factors that affect surface behavior.To develop a method for reconstruction of race surfaces in the laboratory and validate the method by comparison with racetrack measurements of dynamic surface properties.Track-testing device (TTD impact tests were conducted to simulate equine hoof impact on dirt and synthetic race surfaces; tests were performed both in situ (racetrack and using laboratory reconstructions of harvested surface materials. Clegg Hammer in situ measurements were used to guide surface reconstruction in the laboratory. Dynamic surface properties were compared between in situ and laboratory settings. Relationships between racetrack TTD and Clegg Hammer measurements were analyzed using stepwise multiple linear regression.Most dynamic surface property setting differences (racetrack-laboratory were small relative to surface material type differences (dirt-synthetic. Clegg Hammer measurements were more strongly correlated with TTD measurements on the synthetic surface than the dirt surface. On the dirt surface, Clegg Hammer decelerations were negatively correlated with TTD forces.Laboratory reconstruction of racetrack surfaces guided by Clegg Hammer measurements yielded TTD impact measurements similar to in situ values. The negative correlation between TTD and Clegg Hammer measurements confirms the importance of instrument mass when drawing conclusions from testing results. Lighter impact devices may be less appropriate for assessing dynamic surface properties compared to testing equipment designed to simulate hoof impact (TTD.Dynamic impact properties of race surfaces

  19. Institutional practices and policies in acid-base testing: a self reported Croatian survey study on behalf of the Croatian society of medical biochemistry and laboratory medicine Working Group for acid-base balance.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria

    2014-01-01

    The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the

  20. Measuring fertility through mobile‒phone based household surveys: Methods, data quality, and lessons learned from PMA2020 surveys

    OpenAIRE

    Yoonjoung Choi; Qingfeng Li; Blake Zachary

    2018-01-01

    Background: PMA2020 is a survey platform with resident enumerators using mobile phones. Instead of collecting full birth history, total fertility rates (TFR) have been measured with a limited number of questions on recent births. Employing new approaches provides opportunities to test and advance survey methods. Objective: This study aims to assess the quality of fertility data in PMA2020 surveys, focusing on bias introduced from the questionnaire and completeness and distribution of birth...

  1. Current safety practices in nano-research laboratories in China.

    Science.gov (United States)

    Zhang, Can; Zhang, Jing; Wang, Guoyu

    2014-06-01

    China has become a key player in the global nanotechnology field, however, no surveys have specifically examined safety practices in the Chinese nano-laboratories in depth. This study reports results of a survey of 300 professionals who work in research laboratories that handle nanomaterials in China. We recruited participants at three major nano-research laboratories (which carry out research in diverse fields such as chemistry, material science, and biology) and the nano-chemistry session of the national meeting of the Chinese Chemical Society. Results show that almost all nano-research laboratories surveyed had general safety regulations, whereas less than one third of respondents reported having nanospecific safety rules. General safety measures were in place in most surveyed nano-research laboratories, while nanospecific protective measures existed or were implemented less frequently. Several factors reported from the scientific literature including nanotoxicology knowledge gaps, technical limitations on estimating nano-exposure, and the lack of nano-occupational safety legislation may contribute to the current state of affairs. With these factors in mind and embracing the precautionary principle, we suggest strengthening or providing nanosafety training (including raising risk awareness) and establishing nanosafety guidelines in China, to better protect personnel in the nano-workplace.

  2. Customer satisfaction assessment at the Pacific Northwest National Laboratory; TOPICAL

    International Nuclear Information System (INIS)

    DN Anderson; ML Sours

    2000-01-01

    The Pacific Northwest National Laboratory (PNNL) is developing and implementing a customer satisfaction assessment program (CSAP) to assess the quality of research and development provided by the laboratory. This report presents the customer survey component of the PNNL CSAP. The customer survey questionnaire is composed of two major sections: Strategic Value and Project Performance. Both sections contain a set of questions that can be answered with a 5-point Likert scale response. The strategic value section consists of five questions that are designed to determine if a project directly contributes to critical future national needs. The project Performance section consists of nine questions designed to determine PNNL performance in meeting customer expectations. A statistical model for customer survey data is developed and this report discusses how to analyze the data with this model. The properties of the statistical model can be used to establish a gold standard or performance expectation for the laboratory, and then to assess progress. The gold standard is defined using laboratory management input-answers to four questions, in terms of the information obtained from the customer survey: (1) What should the average Strategic Value be for the laboratory project portfolio? (2) What Strategic Value interval should include most of the projects in the laboratory portfolio? (3) What should average Project Performance be for projects with a Strategic Value of about 2? (4) What should average Project Performance be for projects with a Strategic Value of about 4? To be able to provide meaningful answers to these questions, the PNNL customer survey will need to be fully implemented for several years, thus providing a link between management perceptions of laboratory performance and customer survey data

  3. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    International Nuclear Information System (INIS)

    Gauglitz, Erica

    2010-01-01

    This paper presents a survey of parameters for the proper and safe flooring, doors, windows, fume hoods and others, in a radiochemical laboratory. The layout of each item follows guidelines and national standards of the National Commission of Nuclear Energy (CNEN) and the International Atomic Energy Agency (IAEA), aiming to ensure the radiological protection of workers and environment. The adequate items arrangement in the radiochemical laboratory ensures quality and safety in the production of 57 Co 137 Cs and 133 Ba radioactive sealed sources, with activities 185, 9.3 and 5.4 MBq, respectively. These sources are used to verify meter activity equipment and should be available throughout the Nuclear Medicine Center, following the recommendations of CNEN-NN-3.05 standard R equirements for Radiation Protection and Safety Services for Nuclear Medicine , to verify the activity of radiopharmaceuticals that are administered in patients, for diagnosis and therapy. Verification of measuring activity equipment will be used to perform accuracy, reproducibility and linearity tests, which should show results within the limits specified in the standard CNEN-NN-3.05. (author)

  4. Radiological decontamination, survey, and statistical release method for vehicles

    International Nuclear Information System (INIS)

    Goodwill, M.E.; Lively, J.W.; Morris, R.L.

    1996-06-01

    Earth-moving vehicles (e.g., dump trucks, belly dumps) commonly haul radiologically contaminated materials from a site being remediated to a disposal site. Traditionally, each vehicle must be surveyed before being released. The logistical difficulties of implementing the traditional approach on a large scale demand that an alternative be devised. A statistical method for assessing product quality from a continuous process was adapted to the vehicle decontamination process. This method produced a sampling scheme that automatically compensates and accommodates fluctuating batch sizes and changing conditions without the need to modify or rectify the sampling scheme in the field. Vehicles are randomly selected (sampled) upon completion of the decontamination process to be surveyed for residual radioactive surface contamination. The frequency of sampling is based on the expected number of vehicles passing through the decontamination process in a given period and the confidence level desired. This process has been successfully used for 1 year at the former uranium millsite in Monticello, Utah (a cleanup site regulated under the Comprehensive Environmental Response, Compensation, and Liability Act). The method forces improvement in the quality of the decontamination process and results in a lower likelihood that vehicles exceeding the surface contamination standards are offered for survey. Implementation of this statistical sampling method on Monticello projects has resulted in more efficient processing of vehicles through decontamination and radiological release, saved hundreds of hours of processing time, provided a high level of confidence that release limits are met, and improved the radiological cleanliness of vehicles leaving the controlled site

  5. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    Science.gov (United States)

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or 50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  6. A Survey of Various Object Oriented Requirement Engineering Methods

    OpenAIRE

    Anandi Mahajan; Dr. Anurag Dixit

    2013-01-01

    In current years many industries have been moving to the use of object-oriented methods for the development of large scale information systems The requirement of Object Oriented approach in the development of software systems is increasing day by day. This paper is basically a survey paper on various Object-oriented requirement engineering methods. This paper contains a summary of the available Object-oriented requirement engineering methods with their relative advantages and disadvantages...

  7. Safety in the Chemical Laboratory--Chemical Management: A Method for Waste Reduction.

    Science.gov (United States)

    Pine, Stanley H.

    1984-01-01

    Discusses methods for reducing or eliminating waste disposal problems in the chemistry laboratory, considering both economic and environmental aspects of the problems. Proposes inventory control, shared use, solvent recycling, zero effluent, and various means of disposing of chemicals. (JM)

  8. Using mark-recapture distance sampling methods on line transect surveys

    Science.gov (United States)

    Burt, Louise M.; Borchers, David L.; Jenkins, Kurt J.; Marques, Tigao A

    2014-01-01

    Mark–recapture distance sampling (MRDS) methods are widely used for density and abundance estimation when the conventional DS assumption of certain detection at distance zero fails, as they allow detection at distance zero to be estimated and incorporated into the overall probability of detection to better estimate density and abundance. However, incorporating MR data in DS models raises survey and analysis issues not present in conventional DS. Conversely, incorporating DS assumptions in MR models raises issues not present in conventional MR. As a result, being familiar with either conventional DS methods or conventional MR methods does not on its own put practitioners in good a position to apply MRDS methods appropriately. This study explains the sometimes subtly different varieties of MRDS survey methods and the associated concepts underlying MRDS models. This is done as far as possible without giving mathematical details – in the hope that this will make the key concepts underlying the methods accessible to a wider audience than if we were to present the concepts via equations.

  9. Safety and health practice among laboratory staff in Malaysian education sector

    Science.gov (United States)

    Husna Che Hassan, Nurul; Rasdan Ismail, Ahmad; Kamilah Makhtar, Nor; Azwadi Sulaiman, Muhammad; Syuhadah Subki, Noor; Adilah Hamzah, Noor

    2017-10-01

    Safety is the most important issue in industrial sector such as construction and manufacturing. Recently, the increasing number of accident cases reported involving school environment shows the important of safety issues in education sector. Safety awareness among staff in this sector is crucial in order to find out the method to prevent the accident occurred in future. This study was conducted to analyze the knowledge of laboratory staff in term of safety and health practice in laboratory. Survey questionnaires were distributing among 255 of staff laboratory from ten District Education Offices in Kelantan. Descriptive analysis shows that the understanding of safety and health practice are low while doing some job activities in laboratory. Furthermore, some of the staff also did not implemented safety practice that may contribute to unplanned event occur in laboratory. Suggestion that the staff at laboratory need to undergo on Occupational Safety and Health training to maintain and create safe environment in workplaces.

  10. Combining Internet-Based and Postal Survey Methods in a Survey among Gynecologists: Results of a Randomized Trial.

    Science.gov (United States)

    Ernst, Sinja Alexandra; Brand, Tilman; Lhachimi, Stefan K; Zeeb, Hajo

    2018-04-01

    To assess whether a combination of Internet-based and postal survey methods (mixed-mode) compared to postal-only survey methods (postal-only) leads to improved response rates in a physician survey, and to compare the cost implications of the different recruitment strategies. All primary care gynecologists in Bremen and Lower Saxony, Germany, were invited to participate in a cross-sectional survey from January to July 2014. The sample was divided into two strata (A; B) depending on availability of an email address. Within each stratum, potential participants were randomly assigned to mixed-mode or postal-only group. In Stratum A, the mixed-mode group had a lower response rate compared to the postal-only group (12.5 vs. 20.2 percent; RR = 0.61, 95 percent CI: 0.44-0.87). In stratum B, no significant differences were found (15.6 vs. 16.2 percent; RR = 0.95, 95 percent CI: 0.62-1.44). Total costs (in €) per valid questionnaire returned (Stratum A: 399.72 vs. 248.85; Stratum B: 496.37 vs. 455.15) and per percentage point of response (Stratum A: 1,379.02 vs. 861.02; Stratum B 1,116.82 vs. 1,024.09) were higher, whereas variable costs were lower in mixed-mode compared to the respective postal-only groups (Stratum A cost ratio: 0.47, Stratum B cost ratio: 0.71). In this study, primary care gynecologists were more likely to participate by traditional postal-only than by mixed-mode survey methods that first offered an Internet option. However, the lower response rate for the mixed-mode method may be partly due to the older age structure of the responding gynecologists. Variable costs per returned questionnaire were substantially lower in mixed-mode groups and indicate the potential for cost savings if the sample population is sufficiently large. © Health Research and Educational Trust.

  11. Measuring fertility through mobile‒phone based household surveys: Methods, data quality, and lessons learned from PMA2020 surveys

    Directory of Open Access Journals (Sweden)

    Yoonjoung Choi

    2018-05-01

    Full Text Available Background: PMA2020 is a survey platform with resident enumerators using mobile phones. Instead of collecting full birth history, total fertility rates (TFR have been measured with a limited number of questions on recent births. Employing new approaches provides opportunities to test and advance survey methods. Objective: This study aims to assess the quality of fertility data in PMA2020 surveys, focusing on bias introduced from the questionnaire and completeness and distribution of birth month and year, and to estimate TFR adjusted for identified data quality issues. Methods: To assess underestimation from the questionnaire, we simulated births that would be counted using the PMA2020 questionnaires compared to births identified from full birth history. We analyzed the latest Demographic and Health Surveys in ten countries where PMA2020 surveys have been implemented. We assessed the level of reporting completeness for birth month and year and heaping of birth month, analyzing 39 PMA2020 surveys. Finally, TFR were calculated and adjusted for biases introduced from the questionnaire and heaping in birth month. Results: Simple questions introduced minor bias from undercounting multiple births, which was expected and correctable. Meanwhile, incomplete reporting of birth month was relatively high, and the default value of January in data collection software systematically moved births with missing months out of the reference period. On average across the 39 surveys, TFR increased by 1.6Š and 2.4Š, adjusted for undercounted multiple births and heaping on January, respectively. Contribution: This study emphasizes the importance of enumerator training and provides critical insight in software programming in surveys using mobile technologies.

  12. A Scintillometer Assembly for Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Dissing, E; Landstroem, O

    1965-12-15

    An instrument for gamma radiation measurements in connection with geological survey is described. It consists of a scintillation detector with a 5x6 inch sodium iodide crystal and a pulse height analyzer with four independent channels. In field survey work these channels are usually set in fixed positions to record different components of the gamma radiation simultaneously in order to facilitate an identification of the radioactive mineral from which the radiation originates. However, the instrument can also be used for more detailed study of gamma spectra either in the field or in the laboratory. The methods for interpretation of gamma spectra from radioactive ores are briefly reviewed, and a few typical results are given from car-borne and air-borne surveys.

  13. A Scintillometer Assembly for Geological Survey

    International Nuclear Information System (INIS)

    Dissing, E.; Landstroem, O.

    1965-12-01

    An instrument for gamma radiation measurements in connection with geological survey is described. It consists of a scintillation detector with a 5x6 inch sodium iodide crystal and a pulse height analyzer with four independent channels. In field survey work these channels are usually set in fixed positions to record different components of the gamma radiation simultaneously in order to facilitate an identification of the radioactive mineral from which the radiation originates. However, the instrument can also be used for more detailed study of gamma spectra either in the field or in the laboratory. The methods for interpretation of gamma spectra from radioactive ores are briefly reviewed, and a few typical results are given from car-borne and air-borne surveys

  14. The Effects of Using Jigsaw Method Based on Cooperative Learning Model in the Undergraduate Science Laboratory Practices

    Science.gov (United States)

    Karacop, Ataman

    2017-01-01

    The main aim of the present study is to determine the influence of a Jigsaw method based on cooperative learning and a confirmatory laboratory method on prospective science teachers' achievements of physics in science teaching laboratory practice courses. The sample of this study consisted of 33 female and 15 male third-grade prospective science…

  15. Investigating Student Perceptions of the Chemistry Laboratory and Their Approaches to Learning in the Laboratory

    Science.gov (United States)

    Berger, Spencer Granett

    This dissertation explores student perceptions of the instructional chemistry laboratory and the approaches students take when learning in the laboratory environment. To measure student perceptions of the chemistry laboratory, a survey instrument was developed. 413 students responded to the survey during the Fall 2011 semester. Students' perception of the usefulness of the laboratory in helping them learn chemistry in high school was related to several factors regarding their experiences in high school chemistry. Students' perception of the usefulness of the laboratory in helping them learn chemistry in college was also measured. Reasons students provided for the usefulness of the laboratory were categorized. To characterize approaches to learning in the laboratory, students were interviewed midway through semester (N=18). The interviews were used to create a framework describing learning approaches that students use in the laboratory environment. Students were categorized into three levels: students who view the laboratory as a requirement, students who believe that the laboratory augments their understanding, and students who view the laboratory as an important part of science. These categories describe the types of strategies students used when conducting experiments. To further explore the relationship between students' perception of the laboratory and their approaches to learning, two case studies are described. These case studies involve interviews in the beginning and end of the semester. In the interviews, students reflect on what they have learned in the laboratory and describe their perceptions of the laboratory environment. In order to encourage students to adopt higher-level approaches to learning in the laboratory, a metacognitive intervention was created. The intervention involved supplementary questions that students would answer while completing laboratory experiments. The questions were designed to encourage students to think critically about the

  16. Pre-operational HTO/HT surveys in the vicinity of the Chalk River Laboratories tritium extraction plant

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Brown, R.M.

    1993-08-01

    Surveys of the concentrations of HT and HTO in the atmosphere downwind of the Chalk River Laboratories reactor facilities were carried out in 1986 November, and in 1989 March, April and September under different conditions of air temperature, wind direction, and snow or vegetative cover. HT usually amounted to 1-5% of total tritium, but values up to 20% were observed, probably resulting from preferential removal of HTO. In all of the surveys, the greater persistence in the atmosphere of HT than of HTO was evident. The existing levels of HT are such that they will not be augmented significantly by chronic releases from the Tritium Extraction Plant (TEP) when it comes into operation. Hence, operation of the TEP will not facilitate studies of the environmental behaviour of chronically released HT. However, longer term studies of the distribution of HT from the existing facilities would be worthwhile. Soil and vegetation HTO levels in the study area are reported. Further studies of the distribution of tritium between the air, soil and vegetation in areas subjected to chronic exposure would be valuable

  17. A Survey of Functional Behavior Assessment Methods Used by Behavior Analysts in Practice

    Science.gov (United States)

    Oliver, Anthony C.; Pratt, Leigh A.; Normand, Matthew P.

    2015-01-01

    To gather information about the functional behavior assessment (FBA) methods behavior analysts use in practice, we sent a web-based survey to 12,431 behavior analysts certified by the Behavior Analyst Certification Board. Ultimately, 724 surveys were returned, with the results suggesting that most respondents regularly use FBA methods, especially…

  18. Quality assurance of laboratory work and clinical use of laboratory tests in general practice in norway: a survey.

    Science.gov (United States)

    Thue, Geir; Jevnaker, Marianne; Gulstad, Guri Andersen; Sandberg, Sverre

    2011-09-01

    Virtually all the general practices in Norway participate in the Norwegian Quality Improvement of Laboratory Services in Primary Care, NOKLUS. In order to assess and develop NOKLUS's services, it was decided to carry out an investigation in the largest participating group, general practices. In autumn 2008 a questionnaire was sent to all Norwegian general practices asking for feedback on different aspects of NOKLUS's main services: contact with medical laboratory technologists, sending of control materials, use and maintenance of practice-specific laboratory binders, courses, and testing of laboratory equipment. In addition, attitudes were elicited towards possible new services directed at assessing other technical equipment and clinical use of tests. Responses were received from 1290 of 1552 practices (83%). The great majority thought that the frequency of sending out control material should continue as at present, and they were pleased with the feedback reports and follow-up by the laboratory technologists in the counties. Even after many years of practical experience, there is still a need to update laboratory knowledge through visits to practices, courses, and written information. Practices also wanted quality assurance of blood pressure meters and spirometers, and many doctors wanted feedback on their use of laboratory tests. Services regarding quality assurance of point-of-care tests, guidance, and courses should be continued. Quality assurance of other technical equipment and of the doctor's clinical use of laboratory tests should be established as part of comprehensive quality assurance.

  19. Proper survey methods for research of aquatic plant ecology and management

    Science.gov (United States)

    Proper survey methods are essential for objective, quantitative assessment of the distribution and abundance of aquatic plants as part of research and demonstration efforts. For research, the use of the appropriate method is an essential part of the scientific method, to ensure that the experimenta...

  20. A Survey on the Gastrointestinal Parasites of Rabbit and Guinea Pig in a Laboratory Animal House

    Directory of Open Access Journals (Sweden)

    Motamedi, G.,

    2014-05-01

    Full Text Available There is documented evidence that infection in laboratory animals can often influence the outcome of experiments. All infections, apparent or inapparent, are likely to increase biological variability. As a research project concerning the diversity and distribution of parasites of rabbit and guinea pig in a conventional laboratory animal house, about 87 rabbits (from 700 and 105 guinea pigs (from 1500 were selected randomly from a Research, Production & Breeding of Laboratory Animals Department. Samples were collected between 19.02.2010 and 20.05.2011. The samples and animals were examined by dissection and flotation methods. In this study only one species of nematodes (Passalorus ambiguus: 6.9%; one species of protozoa (Eimeria spp.: 21.8% in rabbits and one species of nematodes (Paraspidodera Uncinata: 24.7%; one species of protozoa (Balantidium coli: 11.4% in guinea pigs were identified. However, there was not any cestodes or trematodes identified from this group of laboratory animals.

  1. Research and application of soil-mercury-surveys method for locating uranium

    International Nuclear Information System (INIS)

    You Yunfei; Lu Shili; Jiao Zongrun

    1995-06-01

    Soil-Hg-Surveys method for locating uranium ore was presented. Soil-sampler of drilling bottom, the ability of surveying the deep uranium orebodies was raised by using this method. Application of minicomputer technology to pyrolytic-Hg-analysis raises the degree of automation and precision of the analysis. Application condition of optimum is Hg content of orebodies >1 x 10 -6 . Locating deep is about 100 m. The forecast of uranium orebodies achieved success in two unknown section that are 534 and 510 mining area, therefore two little size deposits expanded into middle size deposits. This method is as well applicable to locating gold, silver, copper, lead zinc and oil-gas natural resource and so on. (8 figs., 3 tabs.)

  2. The capacity of diagnostic laboratories in Kenya for detecting infectious diseases.

    Science.gov (United States)

    Slotved, H-C; Yatich, Kennedy K; Sam, Shem Otoi; Ndhine, Edwardina Otieno

    2017-01-01

    The aim of this study is to present data of the diagnostic capacity of Kenyan laboratories to diagnose a number of human pathogens. The study is based on the data obtained from a biosecurity survey conducted in Kenya in 2014/2015 and data from the Statistical Abstract of Kenya for 2015. The biosecurity survey has previously been published; however, the survey also included information on laboratory capacity to handle a number of pathogens, which have not been published. Data were retrieved from the survey on 86 laboratory facilities. The data include information from relevant categories such as training laboratories, human diagnostic laboratories, veterinary diagnostic laboratories, and research laboratories. The disease incidence in Kenya ranges widely from malaria and diarrhea with an incidence rate of around 10.000 per year to diseases such as cholera and yellow fever with an incidence rate of 1 per year or less for all age groups. The data showed that diseases with the highest number of diagnostic facilities were mainly malaria-, HIV-, tuberculosis-, and diarrhea-related infectious diseases. The study generally shows that the laboratory facilities have the capacity of detecting the infectious diseases with the highest incidence rates. Furthermore, it seems that the number of facilities able to detect a particular disease is related to the incidence rate of the disease.

  3. Flotation of Mineral and Dyes: A Laboratory Experiment for Separation Method Molecular Hitchhikers

    Science.gov (United States)

    Rappon, Tim; Sylvestre, Jarrett A.; Rappon, Manit

    2016-01-01

    Flotation as a method of separation is widely researched and is applied in many industries. It has been used to address a wide range of environmental issues including treatment of wastewater, recovery of heavy metals for recycling, extraction of minerals in mining, and so forth. This laboratory attempts to show how such a simple method can be used…

  4. Results of quality control surveys of radioimmunological determinations of thyrotropin in newborns

    International Nuclear Information System (INIS)

    Roehle, G.; Kruse, R.; Voigt, U.; Torresani, T.

    1983-01-01

    Within the quality control scheme of the Deutsche Gesellschaft fuer Klinische Chemie, seven quality control surveys of thyrotropin (TSH) determinations in blood dried on filter paper have been carried out since 1980. Ninety-six screening laboratories from 12 European countries took part in these surveys. In a single survey each participant usually analysed four different samples; each of these consisted of three spots of dried blood spiked with defined amounts of thyrotropin. For the evaluations of the surveys the participants were asked to give information about their analytical results, and from these, their diagnostic classifications. The medians of the analytical results correlated well with the given thyrotropin concentrations, but the individual estimations from different laboratories varied greatly. Major discrepancies of classification were also apparent, both in the given thyrotropin concentrations and in the individual estimations. Two special collaborative studies with nine selected laboratories showed on the one hand that analysis of the largest possible part of the dried blood sample can help to optimize the precision of the results; on the other hand, considerable drawbacks related to the reagents and the methods were sometimes observed. (orig.) [de

  5. A prospective survey of air and surface fungal contamination in a medical mycology laboratory at a tertiary care university hospital.

    Science.gov (United States)

    Sautour, Marc; Dalle, Frédéric; Olivieri, Claire; L'ollivier, Coralie; Enderlin, Emilie; Salome, Elsa; Chovelon, Isabelle; Vagner, Odile; Sixt, Nathalie; Fricker-Pap, Véronique; Aho, Serge; Fontaneau, Olivier; Cachia, Claire; Bonnin, Alain

    2009-04-01

    Invasive filamentous fungi infections resulting from inhalation of mold conidia pose a major threat in immunocompromised patients. The diagnosis is based on direct smears, cultural symptoms, and culturing fungi. Airborne conidia present in the laboratory environment may cause contamination of cultures, resulting in false-positive diagnosis. Baseline values of fungal contamination in a clinical mycology laboratory have not been determined to date. A 1-year prospective survey of air and surface contamination was conducted in a clinical mycology laboratory during a period when large construction projects were being conducted in the hospital. Air was sampled with a portable air system impactor, and surfaces were sampled with contact Sabouraud agar plates. The collected data allowed the elaboration of Shewhart graphic charts. Mean fungal loads ranged from 2.27 to 4.36 colony forming units (cfu)/m(3) in air and from 0.61 to 1.69 cfu/plate on surfaces. Strict control procedures may limit the level of fungal contamination in a clinical mycology laboratory even in the context of large construction projects at the hospital site. Our data and the resulting Shewhart graphic charts provide baseline values to use when monitoring for inappropriate variations of the fungal contamination in a mycology laboratory as part of a quality assurance program. This is critical to the appropriate management of the fungal risk in hematology, cancer and transplantation patients.

  6. Comparison of different methods for ectoparasite infestation detection in Laboratory bred animals and standardization of their health certificate

    Directory of Open Access Journals (Sweden)

    mohammad Abdigoudarzi

    2014-05-01

    Full Text Available In order to study external parasites of laboratory reared animals at Razi institute, different methods including brushing of animal's surface body, cellophane tape of body surface, peri-anal cellophane tape test (CTT and skin scrapings and digestive method were applied and collected samples were studied. In addition, field collected rats were tested using brushing method. One mouse had been infested by some mites. Rabbits, rats, mice and guinea pigs had not been infested with external parasites. Field collected rats had been highly infested with mites from the family Laelapidae. The, brushing method was confirmed to be a useful method for mite detection. According to the methods used in this study and these recommended by SOP from international animal breeding centers the CTT method was proposed to be useful for preparing health certificate of laboratory animals at the department of laboratory animal breading at Razi institute.

  7. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by graphitized carbon-based solid-phase extraction and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Anderson, Bruce D.; Werner, Stephen L.; Soliven, Paul P.; Coffey, Laura J.; Burkhardt, Mark R.

    2001-01-01

    In 1996, the U.S. Geological Survey National Water Quality Laboratory (NWQL) developed and implemented a graphitized carbon-based solid-phase extraction and high-performance liquid chromatographic analytical method to determine polar pesticide concentrations in surface- and ground-water samples. Subsequently, the NWQL developed a complementary analysis that uses high-performance liquid chromatography/mass spectrometry to detect, identify, and quantify polar pesticides and pesticide metabolites in filtered water at concentrations as low as 10 nanograms per liter. This new method was designed to improve sensitivity and selectivity over the prior method, and to reduce known interferences from natural organic matter.In this new method, pesticides are extracted from filtered water samples by useing a 0.5-gram graphitized carbon-based solid-phase extraction cartridge, eluted from the cartridge, and concentrations determined by using high-performance liquid chromatography with electrospray ionization-mass spectrometry. The upper concentration limit is 1.000 microgram per liter (μg/L) for most compounds. Single-operator method detection limits in organic-free water samples fortified with pesticides at a concentration of 0.025 μg/L ranged from 0.0019 to 0.022 μg/L for all compounds in the method. The grand mean (mean of mean recoveries for individual compounds) recoveries in organic-free water samples ranged from 72 to 89 percent, fortified with pesticides at three concentrations between 0.025 and 0.5 μg/L. Grand mean recoveries in ground- and surface-water samples ranged from 46 to 119 percent, also fortified with pesticides at three concentrations between 0.025 and 0.5 μg/L. Long-term recoveries from reagent water spikes were used to demonstrate that 38 of 65 compounds can be reported without qualification of the quantitative result across the analytical range of the method. The remaining 27 are reported with qualified estimates of concentration because of greater

  8. National Chemistry Teacher Safety Survey

    Science.gov (United States)

    Plohocki, Barbra A.

    This study evaluated the status of secondary school instructional chemistry laboratory safety using a survey instrument which focused on Teacher background Information, Laboratory Safety Equipment, Facility Safety, General Safety, and a Safety Content Knowledge Survey. A fifty question survey instrument based on recent research and questions developed by the researcher was mailed to 500 secondary school chemistry teachers who participated in the 1993 one-week Woodrow Wilson National Fellowship Foundation Chemistry Institute conducted at Princeton University, New Jersey. The data received from 303 respondents was analyzed by t tests and Analysis of Variance (ANOVA). The level of significance for the study was set at ~\\ performance on the Safety Content Knowledge Survey and secondary school chemistry teachers who have had undergraduate and/or graduate safety training and those who have not had undergraduate and/or graduate safety training. Secondary school chemistry teachers who attended school district sponsored safety inservices did not score higher on the Safety Content Knowledge Survey than teachers who did not attend school district sponsored safety inservice sessions. The type of school district (urban, suburban, or rural) had no significant correlation to the type of laboratory safety equipment found in the instructional chemistry laboratory. The certification area (chemistry or other type of certificate which may or may not include chemistry) of the secondary school teacher had no significant correlation to the type of laboratory equipment found in the instructional chemistry laboratory. Overall, this study indicated a majority of secondary school chemistry teachers were interested in attending safety workshops applicable to chemistry safety. Throughout this research project, many teachers indicated they were not adequately instructed on the collegiate level in science safety and had to rely on common sense and self-study in their future teaching careers.

  9. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    Science.gov (United States)

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Moderate-Use Pesticides and Selected Degradates in Water by C-18 Solid-Phase Extraction and Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Sandstrom, Mark W.; Stroppel, Max E.; Foreman, William T.; Schroeder, Michael P.

    2001-01-01

    A method for the isolation and analysis of 21 parent pesticides and 20 pesticide degradates in natural-water samples is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase-extraction columns that contain octadecyl-bonded porous silica to extract the analytes. The columns are dried by using nitrogen gas, and adsorbed analytes are eluted with ethyl acetate. Extracted analytes are determined by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 2 micrograms per liter (?g/L) for most analytes. Single-operator method detection limits in reagent-water samples range from 0.00 1 to 0.057 ?g/L. Validation data also are presented for 14 parent pesticides and 20 degradates that were determined to have greater bias or variability, or shorter holding times than the other compounds. The estimated maximum holding time for analytes in pesticide-grade water before extraction was 4 days. The estimated maximum holding time for analytes after extraction on the dry solid-phase-extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time. The method complements existing U.S. Geological Survey Method O-1126-95 (NWQL Schedules 2001 and 2010) by using identical sample preparation and comparable instrument analytical conditions so that sample extracts can be analyzed by either method to expand the range of analytes determined from one water sample.

  11. Integrated management system best practices in radioecological laboratories

    International Nuclear Information System (INIS)

    Carvalho, Claudia Aparecida Zerbinatti de

    2009-01-01

    This paper presents a Master dissertation advancements with the target of studying the best practices, in order to give support to an IMS conceptual model ?Integrated Management System (quality, environment, work safety and health), applied to radioecological laboratories. The planning of the proposed research comprises the following stages: first stage - the bibliographic and documental survey in IMS; a survey and study of the applied standards (QMS NBR ISO 9000 (2005), NBR ISO 9001 (2008), NBR ISO 9004 (2000), EMS 14001(2004) and OHSMS OHSAS 18001 (2007) and OHSAS 18002 (2008)); identification and characterization in radioecological laboratories processes; a methodological study of better practices and benchmarking is carried out. In the second stage of the research, the development of a case study is forecast (qualitative research, with electronic questionnaires and personal interviews, when possible), preceded by a survey and selection of international and national radioecological laboratories to be studied and, in sequence, these laboratories should be contacted and agree to participate in the research; in a third stage, the construction of a matrix of better practices, which incur in the results able to subside an IMS conceptual model proposition for radioecological laboratories; the fourth and last stage of the research comprises the construction of a conceptual proposal of an IMS structure for radioecological laboratories. The first stage of the research results are presented concisely, as well as a preliminary selection of laboratories to be studied. (author)

  12. Integrated management system best practices in radioecological laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Claudia Aparecida Zerbinatti de [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Dept. da Qualidade], e-mail: clau.zerbina@gmail.com; Zouain, Desiree Moraes [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: dmzouain@ipen.br

    2009-07-01

    This paper presents a Master dissertation advancements with the target of studying the best practices, in order to give support to an IMS conceptual model ?Integrated Management System (quality, environment, work safety and health), applied to radioecological laboratories. The planning of the proposed research comprises the following stages: first stage - the bibliographic and documental survey in IMS; a survey and study of the applied standards (QMS NBR ISO 9000 (2005), NBR ISO 9001 (2008), NBR ISO 9004 (2000), EMS 14001(2004) and OHSMS OHSAS 18001 (2007) and OHSAS 18002 (2008)); identification and characterization in radioecological laboratories processes; a methodological study of better practices and benchmarking is carried out. In the second stage of the research, the development of a case study is forecast (qualitative research, with electronic questionnaires and personal interviews, when possible), preceded by a survey and selection of international and national radioecological laboratories to be studied and, in sequence, these laboratories should be contacted and agree to participate in the research; in a third stage, the construction of a matrix of better practices, which incur in the results able to subside an IMS conceptual model proposition for radioecological laboratories; the fourth and last stage of the research comprises the construction of a conceptual proposal of an IMS structure for radioecological laboratories. The first stage of the research results are presented concisely, as well as a preliminary selection of laboratories to be studied. (author)

  13. An Enzymatic Clinical Chemistry Laboratory Experiment Incorporating an Introduction to Mathematical Method Comparison Techniques

    Science.gov (United States)

    Duxbury, Mark

    2004-01-01

    An enzymatic laboratory experiment based on the analysis of serum is described that is suitable for students of clinical chemistry. The experiment incorporates an introduction to mathematical method-comparison techniques in which three different clinical glucose analysis methods are compared using linear regression and Bland-Altman difference…

  14. Doing laboratory ethnography: reflections on method in scientific workplaces.

    Science.gov (United States)

    Stephens, Neil; Lewis, Jamie

    2017-04-01

    Laboratory ethnography extended the social scientist's gaze into the day-to-day accomplishment of scientific practice. Here we reflect upon our own ethnographies of biomedical scientific workspaces to provoke methodological discussion on the doing of laboratory ethnography. What we provide is less a 'how to' guide and more a commentary on what to look for and what to look at. We draw upon our empirical research with stem cell laboratories and animal houses, teams producing robotic surgical tools, musicians sonifying data science, a psychiatric genetics laboratory, and scientists developing laboratory grown meat. We use these cases to example a set of potential ethnographic themes worthy of pursuit: science epistemics and the extended laboratory, the interaction order of scientific work, sensory realms and the rending of science as sensible, conferences as performative sites, and the spaces, places and temporalities of scientific work.

  15. Standard guide for qualification of measurement methods by a laboratory within the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide provides guidance for selecting, validating, and qualifying measurement methods when qualification is required for a specific program. The recommended practices presented in this guide provide a major part of a quality assurance program for the laboratory data (see Fig. 1). Qualification helps to assure that the data produced will meet established requirements. 1.2 The activities intended to assure the quality of analytical laboratory measurement data are diagrammed in Fig. 1. Discussion and guidance related to some of these activities appear in the following sections: Section Selection of Measurement Methods 5 Validation of Measurement Methods 6 Qualification of Measurement Methods 7 Control 8 Personnel Qualification 9 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitati...

  16. Survey of near-field flow calculations for nuclear waste repositories NMA L21

    International Nuclear Information System (INIS)

    Wilson, R.N.; Holland, D.H.

    1979-11-01

    A survey of methods and codes which describe the flow of groundwater and the migration of radioactive waste in and about nuclear repositories was performed. A number of laboratories engaged in studies of waste migration and groundwater flow were visited in order to discuss the general problem and obtain reports of work being performed. The results of this survey are discussed

  17. Survey of Technetium Analytical Production Methods Supporting Hanford Nuclear Materials Processing

    International Nuclear Information System (INIS)

    TROYER, G.L.

    1999-01-01

    This document provides a historical survey of analytical methods used for measuring 99 Tc in nuclear fuel reprocessing materials and wastes at Hanford. Method challenges including special sludge matrices tested are discussed. Special problems and recommendations are presented

  18. Quantification of Soil Physical Properties by Using X-Ray Computerized Tomography (CT) and Standard Laboratory (STD) Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Maria Ambert [Iowa State Univ., Ames, IA (United States)

    2003-12-12

    The implementation of x-ray computerized tomography (CT) on agricultural soils has been used in this research to quantify soil physical properties to be compared with standard laboratory (STD) methods. The overall research objective was to more accurately quantify soil physical properties for long-term management systems. Two field studies were conducted at Iowa State University's Northeast Research and Demonstration Farm near Nashua, IA using two different soil management strategies. The first field study was conducted in 1999 using continuous corn crop rotation for soil under chisel plow with no-till treatments. The second study was conducted in 2001 and on soybean crop rotation for the same soil but under chisel plow and no-till practices with wheel track and no-wheel track compaction treatments induced by a tractor-manure wagon. In addition, saturated hydraulic (K{sub s}) conductivity and the convection-dispersion (CDE) model were also applied using long-term soil management systems only during 2001. The results obtained for the 1999 field study revealed no significant differences between treatments and laboratory methods, but significant differences were found at deeper depths of the soil column for tillage treatments. The results for standard laboratory procedure versus CT method showed significant differences at deeper depths for the chisel plow treatment and at the second lower depth for no-till treatment for both laboratory methods. The macroporosity distribution experiment showed significant differences at the two lower depths between tillage practices. Bulk density and percent porosity had significant differences at the two lower depths of the soil column. The results obtained for the 2001 field study showed no significant differences between tillage practices and compaction practices for both laboratory methods, but significant differences between tillage practices with wheel track and no-wheel compaction treatments were found along the soil

  19. A professional development model for medical laboratory scientists working in the microbiology laboratory.

    Science.gov (United States)

    Amerson, Megan H; Pulido, Lila; Garza, Melinda N; Ali, Faheem A; Greenhill, Brandy; Einspahr, Christopher L; Yarsa, Joseph; Sood, Pramilla K; Hu, Peter C

    2012-01-01

    The University of Texas M.D. Anderson Cancer Center, Division of Pathology and Laboratory Medicine is committed to providing the best pathology and medicine through: state-of-the art techniques, progressive ground-breaking research, education and training for the clinical diagnosis and research of cancer and related diseases. After surveying the laboratory staff and other hospital professionals, the Department administrators and Human Resource generalists developed a professional development model for Microbiology to support laboratory skills, behavior, certification, and continual education within its staff. This model sets high standards for the laboratory professionals to allow the labs to work at their fullest potential; it provides organization to training technologists based on complete laboratory needs instead of training technologists in individual areas in which more training is required if the laboratory needs them to work in other areas. This model is a working example for all microbiology based laboratories who want to set high standards and want their staff to be acknowledged for demonstrated excellence and professional development in the laboratory. The PDM model is designed to focus on the needs of the laboratory as well as the laboratory professionals.

  20. [Data validation methods and discussion on Chinese materia medica resource survey].

    Science.gov (United States)

    Zhang, Yue; Ma, Wei-Feng; Zhang, Xiao-Bo; Zhu, Shou-Dong; Guo, Lan-Ping; Wang, Xing-Xing

    2013-07-01

    From the beginning of the fourth national survey of the Chinese materia medica resources, there were 22 provinces have conducted pilots. The survey teams have reported immense data, it put forward the very high request to the database system construction. In order to ensure the quality, it is necessary to check and validate the data in database system. Data validation is important methods to ensure the validity, integrity and accuracy of census data. This paper comprehensively introduce the data validation system of the fourth national survey of the Chinese materia medica resources database system, and further improve the design idea and programs of data validation. The purpose of this study is to promote the survey work smoothly.

  1. Survey of safety practices among hospital laboratories in Oromia Regional State, Ethiopia.

    Science.gov (United States)

    Sewunet, Tsegaye; Kebede, Wakjira; Wondafrash, Beyene; Workalemau, Bereket; Abebe, Gemeda

    2014-10-01

    Unsafe working practices, working environments, disposable waste products, and chemicals in clinical laboratories contribute to infectious and non-infectious hazards. Staffs, the community, and patients are less safe. Furthermore, such practices compromise the quality of laboratory services. We conducted a study to describe safety practices in public hospital laboratories of Oromia Regional State, Ethiopia. Randomly selected ten public hospital laboratories in Oromia Regional State were studied from Oct 2011- Feb 2012. Self-administered structured questionnaire and observation checklists were used for data collection. The respondents were heads of the laboratories, senior technicians, and safety officers. The questionnaire addressed biosafety label, microbial hazards, chemical hazards, physical/mechanical hazards, personal protective equipment, first aid kits and waste disposal system. The data was analyzed using descriptive analysis with SPSS version16 statistical software. All of the respondents reported none of the hospital laboratories were labeled with the appropriate safety label and safety symbols. These respondents also reported they may contain organisms grouped under risk group IV in the absence of microbiological safety cabinets. Overall, the respondents reported that there were poor safety regulations or standards in their laboratories. There were higher risks of microbial, chemical and physical/mechanical hazards. Laboratory safety in public hospitals of Oromia Regional State is below the standard. The laboratory workers are at high risk of combined physical, chemical and microbial hazards. Prompt recognition of the problem and immediate action is mandatory to ensure safe working environment in health laboratories.

  2. Studying Cannabis Use Behaviors With Facebook and Web Surveys: Methods and Insights

    Science.gov (United States)

    2018-01-01

    The rapid and wide-reaching expansion of internet access and digital technologies offers epidemiologists numerous opportunities to study health behaviors. One particularly promising new data collection strategy is the use of Facebook’s advertising platform in conjunction with Web-based surveys. Our research team at the Center for Technology and Behavioral Health has used this quick and cost-efficient method to recruit large samples and address unique scientific questions related to cannabis use. In conducting this research, we have gleaned several insights for using this sampling method effectively and have begun to document the characteristics of the resulting data. We believe this information could be useful to other researchers attempting to study cannabis use or, potentially, other health behaviors. The first aim of this paper is to describe case examples of procedures for using Facebook as a survey sampling method for studying cannabis use. We then present several distinctive features of the data produced using this method. Finally, we discuss the utility of this sampling method for addressing specific types of epidemiological research questions. Overall, we believe that sampling with Facebook advertisements and Web surveys is best conceptualized as a targeted, nonprobability-based method for oversampling cannabis users across the United States. PMID:29720366

  3. Survey of subsurface treatment technologies for environmental restoration sites at Sandia National Laboratories, New Mexico.

    Energy Technology Data Exchange (ETDEWEB)

    McGrath, Lucas K.; Ho, Clifford Kuofei; Wright, Jerome L.

    2003-08-01

    This report provides a survey of remediation and treatment technologies for contaminants of concern at environmental restoration (ER) sites at Sandia National Laboratories, New Mexico. The sites that were evaluated include the Tijeras Arroyo Groundwater, Technical Area V, and Canyons sites. The primary contaminants of concern at these sites include trichloroethylene (TCE), tetrachloroethylene (PCE), and nitrate in groundwater. Due to the low contaminant concentrations (close to regulatory limits) and significant depths to groundwater ({approx}500 feet) at these sites, few in-situ remediation technologies are applicable. The most applicable treatment technologies include monitored natural attenuation and enhanced bioremediation/denitrification to reduce the concentrations of TCE, PCE, and nitrate in the groundwater. Stripping technologies to remove chlorinated solvents and other volatile organic compounds from the vadose zone can also be implemented, if needed.

  4. Matrix diffusion studies by electrical conductivity methods. Comparison between laboratory and in-situ measurements

    International Nuclear Information System (INIS)

    Ohlsson, Y.; Neretnieks, I.

    1998-01-01

    Traditional laboratory diffusion experiments in rock material are time consuming, and quite small samples are generally used. Electrical conductivity measurements, on the other hand, provide a fast means for examining transport properties in rock and allow measurements on larger samples as well. Laboratory measurements using electrical conductivity give results that compare well to those from traditional diffusion experiments. The measurement of the electrical resistivity in the rock surrounding a borehole is a standard method for the detection of water conducting fractures. If these data could be correlated to matrix diffusion properties, in-situ diffusion data from large areas could be obtained. This would be valuable because it would make it possible to obtain data very early in future investigations of potentially suitable sites for a repository. This study compares laboratory electrical conductivity measurements with in-situ resistivity measurements from a borehole at Aespoe. The laboratory samples consist mainly of Aespoe diorite and fine-grained granite and the rock surrounding the borehole of Aespoe diorite, Smaaland granite and fine-grained granite. The comparison shows good agreement between laboratory measurements and in-situ data

  5. Validation of a densimeter calibration procedure for a secondary calibration laboratory

    International Nuclear Information System (INIS)

    Alpizar Herrera, Juan Carlos

    2014-01-01

    A survey was conducted to quantify the need for calibration of a density measurement instrument at the research units at the Sede Rodrigo Facio of the Universidad de Costa Rica. A calibration procedure was documented for the instrument that presented the highest demand in the survey by the calibration service. A study of INTE-ISO/IEC 17025: 2005 and specifically in section 5.4 of this standard was done, to document the procedure for calibrating densimeters. Densimeter calibration procedures and standards were sought from different national and international sources. The method of hydrostatic weighing or Cuckow method was the basis of the defined procedure. Documenting the calibration procedure and creating other documents was performed for data acquisition log, intermediate calculation log and calibration certificate copy. A veracity test was performed using as reference laboratory a laboratory of calibration secondary national as part of the validation process of the documented procedure. The results of the E_n statistic of 0.41; 0.34 and 0.46 for the calibration points 90%, 50% and 10% were obtained for the densimeter scale respectively. A reproducibility analysis of the method was performed with satisfactory results. Different suppliers were contacted to estimate the economic costs of the equipment and materials, needed to develop the documented method of densimeter calibration. The acquisition of an analytical balance was recommended, instead of a precision scale, in order to improve the results obtained with the documented method [es

  6. Survey of subsurface geophysical exploration technologies adaptable to an airborne platform

    International Nuclear Information System (INIS)

    Taylor, K.A.

    1992-12-01

    This report has been prepared by the US Department of Energy (DOE) as part of a Research Development Demonstration Testing and Evaluation (RDDT ampersand E) project by EG ampersand G Energy Measurement's (EG ampersand G/EM) Remote Sensing Laboratory. It examines geophysical detection techniques which may be used in Environmental Restoration/Waste Management (ER/WM) surveys to locate buried waste, waste containers, potential waste migratory paths, and aquifer depths. Because of the Remote Sensing Laboratory's unique survey capabilities, only those technologies which have been adapted or are capable of being adapted to an airborne platform were studied. This survey describes several of the available subsurface survey technologies and discusses the basic capabilities of each: the target detectability, required geologic conditions, and associated survey methods. Because the airborne capabilities of these survey techniques have not been fully developed, the chapters deal mostly with the ground-based capabilities of each of the technologies, with reference made to the airborne capabilities where applicable. The information about each survey technique came from various contractors whose companies employ these specific technologies. EG ampersand G/EM cannot guarantee or verify the accuracy of the contractor information; however, the data given is an indication of the technologies that are available

  7. Safeguards Knowledge Management & Retention at U.S. National Laboratories.

    Energy Technology Data Exchange (ETDEWEB)

    Haddal, Risa [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Rebecca [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bersell, Bridget [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Frazar, Sarah [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Burbank, Roberta [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stevens, Rebecca [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cain, Ron [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kirk, Bernadette [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Morell, Sean [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    In 2017, four U.S. National Laboratories collaborated on behalf of DOE/NNSA to explore the safeguards knowledge retention problem, identify possible approaches, and develop a strategy to address it. The one-year effort consisted of four primary tasks. First, the project sought to identify critical safeguards information at risk of loss. Second, a survey and workshop were conducted to assess nine U.S. National Laboratories' efforts to determine current safeguards knowledge retention practices and challenges, and identify best practices. Third, specific tools were developed to identify and predict critical safeguards knowledge gaps and how best to recruit in order to fill those gaps. Finally, based on findings from the first three tasks and research on other organizational approaches to address similar issues, a strategy was developed on potential knowledge retention methods, customized HR policies, and best practices that could be implemented across the National Laboratory Complex.

  8. Data analysis considerations for pesticides determined by National Water Quality Laboratory schedule 2437

    Science.gov (United States)

    Shoda, Megan E.; Nowell, Lisa H.; Stone, Wesley W.; Sandstrom, Mark W.; Bexfield, Laura M.

    2018-04-02

    In 2013, the U.S. Geological Survey National Water Quality Laboratory (NWQL) made a new method available for the analysis of pesticides in filtered water samples: laboratory schedule 2437. Schedule 2437 is an improvement on previous analytical methods because it determines the concentrations of 225 fungicides, herbicides, insecticides, and associated degradates in one method at similar or lower concentrations than previously available methods. Additionally, the pesticides included in schedule 2437 were strategically identified in a prioritization analysis that assessed likelihood of occurrence, prevalence of use, and potential toxicity. When the NWQL reports pesticide concentrations for analytes in schedule 2437, the laboratory also provides supplemental information useful to data users for assessing method performance and understanding data quality. That supplemental information is discussed in this report, along with an initial analysis of analytical recovery of pesticides in water-quality samples analyzed by schedule 2437 during 2013–2015. A total of 523 field matrix spike samples and their paired environmental samples and 277 laboratory reagent spike samples were analyzed for this report (1,323 samples total). These samples were collected in the field as part of the U.S. Geological Survey National Water-Quality Assessment groundwater and surface-water studies and as part of the NWQL quality-control program. This report reviews how pesticide samples are processed by the NWQL, addresses how to obtain all the data necessary to interpret pesticide concentrations, explains the circumstances that result in a reporting level change or the occurrence of a raised reporting level, and describes the calculation and assessment of recovery. This report also discusses reasons why a data user might choose to exclude data in an interpretive analysis and outlines the approach used to identify the potential for decreased data quality in the assessment of method recovery. The

  9. Autoclaving practice in microbiology laboratories: report of a survey. The Public Health Laboratory Service Subcommittee on laboratory autoclaves.

    Science.gov (United States)

    1978-01-01

    The performance of autoclaves in 27 laboratories, operated in accordance with the normal routine of local practice, has been monitored using thermometric equipment. Sterilising performance was unsatisfactory on 10 of 62 occasions, and cooling was inadequate on 52 of 60 occasions. PMID:649767

  10. Response Matrix Method Development Program at Savannah River Laboratory

    International Nuclear Information System (INIS)

    Sicilian, J.M.

    1976-01-01

    The Response Matrix Method Development Program at Savannah River Laboratory (SRL) has concentrated on the development of an effective system of computer codes for the analysis of Savannah River Plant (SRP) reactors. The most significant contribution of this program to date has been the verification of the accuracy of diffusion theory codes as used for routine analysis of SRP reactor operation. This paper documents the two steps carried out in achieving this verification: confirmation of the accuracy of the response matrix technique through comparison with experiment and Monte Carlo calculations; and establishment of agreement between diffusion theory and response matrix codes in situations which realistically approximate actual operating conditions

  11. A Survey of Methods for Gas-Lift Optimization

    Directory of Open Access Journals (Sweden)

    Kashif Rashid

    2012-01-01

    Full Text Available This paper presents a survey of methods and techniques developed for the solution of the continuous gas-lift optimization problem over the last two decades. These range from isolated single-well analysis all the way to real-time multivariate optimization schemes encompassing all wells in a field. While some methods are clearly limited due to their neglect of treating the effects of inter-dependent wells with common flow lines, other methods are limited due to the efficacy and quality of the solution obtained when dealing with large-scale networks comprising hundreds of difficult to produce wells. The aim of this paper is to provide an insight into the approaches developed and to highlight the challenges that remain.

  12. The State Public Health Laboratory System.

    Science.gov (United States)

    Inhorn, Stanley L; Astles, J Rex; Gradus, Stephen; Malmberg, Veronica; Snippes, Paula M; Wilcke, Burton W; White, Vanessa A

    2010-01-01

    This article describes the development since 2000 of the State Public Health Laboratory System in the United States. These state systems collectively are related to several other recent public health laboratory (PHL) initiatives. The first is the Core Functions and Capabilities of State Public Health Laboratories, a white paper that defined the basic responsibilities of the state PHL. Another is the Centers for Disease Control and Prevention National Laboratory System (NLS) initiative, the goal of which is to promote public-private collaboration to assure quality laboratory services and public health surveillance. To enhance the realization of the NLS, the Association of Public Health Laboratories (APHL) launched in 2004 a State Public Health Laboratory System Improvement Program. In the same year, APHL developed a Comprehensive Laboratory Services Survey, a tool to measure improvement through the decade to assure that essential PHL services are provided.

  13. Studying Cannabis Use Behaviors With Facebook and Web Surveys: Methods and Insights.

    Science.gov (United States)

    Borodovsky, Jacob T; Marsch, Lisa A; Budney, Alan J

    2018-05-02

    The rapid and wide-reaching expansion of internet access and digital technologies offers epidemiologists numerous opportunities to study health behaviors. One particularly promising new data collection strategy is the use of Facebook's advertising platform in conjunction with Web-based surveys. Our research team at the Center for Technology and Behavioral Health has used this quick and cost-efficient method to recruit large samples and address unique scientific questions related to cannabis use. In conducting this research, we have gleaned several insights for using this sampling method effectively and have begun to document the characteristics of the resulting data. We believe this information could be useful to other researchers attempting to study cannabis use or, potentially, other health behaviors. The first aim of this paper is to describe case examples of procedures for using Facebook as a survey sampling method for studying cannabis use. We then present several distinctive features of the data produced using this method. Finally, we discuss the utility of this sampling method for addressing specific types of epidemiological research questions. Overall, we believe that sampling with Facebook advertisements and Web surveys is best conceptualized as a targeted, nonprobability-based method for oversampling cannabis users across the United States. ©Jacob T Borodovsky, Lisa A Marsch, Alan J Budney. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 02.05.2018.

  14. An automated radiological survey method for performing site remediation and decommissioning

    International Nuclear Information System (INIS)

    Handy, R.G.; Bolch, W.E.; Harder, G.F.; Tolaymat, T.M.

    1994-01-01

    A portable, computer-based method of performing environmental monitoring and assessment for site remediation and decommissioning has been developed. The integrated system has been developed to provide for survey time reductions and real-time data analysis. The technique utilizes a notebook 486 computer with the necessary hardware and software components that makes it possible to be used in an almost unlimited number of environmental monitoring and assessment scenarios. The results from a pilot, open-quotes hide-and-seekclose quotes gamma survey and an actual alpha decontamination survey were elucidated. It was found that a open-quotes hide-and-seekclose quotes survey could come up with timely and accurate conclusions about the position of the source. The use of the automated system in a Th-232 alpha survey resulted in a reduction in the standard time necessary to do a radiological survey. In addition, the ability to analyze the data on-site allowed for identification and location of areas which needed further decontamination. Finally, a discussion on possible future improvements and field conclusions was made

  15. Identification of atypical Aeromonas salmonicida : Inter-laboratory evaluation and harmonization of methods

    DEFF Research Database (Denmark)

    Dalsgaard, Inger; Gudmundsdottir, B.K.; Helgason, S.

    1998-01-01

    the biochemical identification of atypical Aer. salmonicida before and after standardization of media and methods. Five laboratories examined 25 isolates of Aer. salmonicida from diverse fish species and geographical locations including the reference strains of Aer. salmonicida subsp, salmonicida (NCMB 1102......) and Aer. salmonicida subsp. achromogenes (NCMB 1110), Without standardization of the methods, 100% agreement was obtained only for two tests: motility and ornithine decarboxylase. The main reason for the discrepancies found was the variation of the incubation time prior to reading the biochemical...

  16. LABORATORY EVALUATION OF AIR FLOW MEASUREMENT METHODS FOR RESIDENTIAL HVAC RETURNS

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-02-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  17. Research on 3-D terrain correction methods of airborne gamma-ray spectrometry survey

    International Nuclear Information System (INIS)

    Liu Yanyang; Liu Qingcheng; Zhang Zhiyong

    2008-01-01

    The general method of height correction is not effectual in complex terrain during the process of explaining airborne gamma-ray spectrometry data, and the 2-D terrain correction method researched in recent years is just available for correction of section measured. A new method of 3-D sector terrain correction is studied. The ground radiator is divided into many small sector radiators by the method, then the irradiation rate is calculated in certain survey distance, and the total value of all small radiate sources is regarded as the irradiation rate of the ground radiator at certain point of aero- survey, and the correction coefficients of every point are calculated which then applied to correct to airborne gamma-ray spectrometry data. The method can achieve the forward calculation, inversion calculation and terrain correction for airborne gamma-ray spectrometry survey in complex topography by dividing the ground radiator into many small sectors. Other factors are considered such as the un- saturated degree of measure scope, uneven-radiator content on ground, and so on. The results of for- ward model and an example analysis show that the 3-D terrain correction method is proper and effectual. (authors)

  18. Proficiency Testing for Bacterial Whole Genome Sequencing: An End-User Survey of Current Capabilities, Requirements and Priorities

    DEFF Research Database (Denmark)

    Moran-Gilad, Jacob; Sintchenko, Vitali; Karlsmose Pedersen, Susanne

    2015-01-01

    The advent of next-generation sequencing (NGS) has revolutionised public health microbiology. Given the potential impact of NGS, it is paramount to ensure standardisation of ‘wet’ laboratory and bioinformatic protocols and promote comparability of methods employed by different laboratories...... and their outputs. Therefore, one of the ambitious goals of the Global Microbial Identifier (GMI) initiative (http://​www.​globalmicrobiali​dentifier.​org/​) has been to establish a mechanism for inter-laboratory NGS proficiency testing (PT). This report presents findings from the survey recently conducted...... by Working Group 4 among GMI members in order to ascertain NGS end-use requirements and attitudes towards NGS PT. The survey identified the high professional diversity of laboratories engaged in NGS-based public health projects and the wide range of capabilities within institutions, at a notable range...

  19. Proficiency testing for bacterial whole genome sequencing: an end-user survey of current capabilities, requirements and priorities

    DEFF Research Database (Denmark)

    Moran-Gilad, Jacob; Sintchenko, Vitali; Karlsmose Pedersen, Susanne

    2015-01-01

    The advent of next-generation sequencing (NGS) has revolutionised public health microbiology. Given the potential impact of NGS, it is paramount to ensure standardisation of 'wet' laboratory and bioinformatic protocols and promote comparability of methods employed by different laboratories...... and their outputs. Therefore, one of the ambitious goals of the Global Microbial Identifier (GMI) initiative (http://www.globalmicrobialidentifier.org/) has been to establish a mechanism for inter-laboratory NGS proficiency testing (PT). This report presents findings from the survey recently conducted by Working...... Group 4 among GMI members in order to ascertain NGS end-use requirements and attitudes towards NGS PT. The survey identified the high professional diversity of laboratories engaged in NGS-based public health projects and the wide range of capabilities within institutions, at a notable range of costs...

  20. Comparison of Survey Data Collection Methods

    Directory of Open Access Journals (Sweden)

    VIDAL DÍAZ DE RADA

    2017-01-01

    Full Text Available This paper presents the results of a mixed-mode survey of the general population using a combination of postal, telephone, and Internet survey protocols. Potential respondents were invited to participate by ordinary mail and were allowed to choose their preferred response mode. The paper focuses on response quality (taking non-responses into consideration, fieldwork time and data collection cost. The results reveal that the Internet survey produces the lowest rate of non-responses and requires significantly less fieldwork time, although it is slightly more costly than the postal survey. However, when differences in cost structure are taken into account, we find that the same number of completed questionnaires could have been obtained through the Internet alone at a cost that is 18.2% lower than the mixed-mode survey.

  1. Google Street View as an alternative method to car surveys in large-scale vegetation assessments.

    Science.gov (United States)

    Deus, Ernesto; Silva, Joaquim S; Catry, Filipe X; Rocha, Miguel; Moreira, Francisco

    2015-10-01

    Car surveys (CS) are a common method for assessing the distribution of alien invasive plants. Google Street View (GSV), a free-access web technology where users may experience a virtual travel along roads, has been suggested as a cost-effective alternative to car surveys. We tested if we could replicate the results from a countrywide survey conducted by car in Portugal using GSV as a remote sensing tool, aiming at assessing the distribution of Eucalyptus globulus Labill. wildlings on roadsides adjacent to eucalypt stands. Georeferenced points gathered along CS were used to create road transects visible as lines overlapping the road in GSV environment, allowing surveying the same sampling areas using both methods. This paper presents the results of the comparison between the two methods. Both methods produced similar models of plant abundance, selecting the same explanatory variables, in the same hierarchical order of importance and depicting a similar influence on plant abundance. Even though the GSV model had a lower performance and the GSV survey detected fewer plants, additional variables collected exclusively with GSV improved model performance and provided a new insight into additional factors influencing plant abundance. The survey using GSV required ca. 9 % of the funds and 62 % of the time needed to accomplish the CS. We conclude that GSV may be a cost-effective alternative to CS. We discuss some advantages and limitations of GSV as a survey method. We forecast that GSV may become a widespread tool in road ecology, particularly in large-scale vegetation assessments.

  2. U.S. Geological Survey geohydrologic studies and monitoring at the Idaho National Laboratory, southeastern Idaho

    Science.gov (United States)

    Bartholomay, Roy C.

    2017-09-14

    BackgroundThe U.S. Geological Survey (USGS) geohydrologic studies and monitoring at the Idaho National Laboratory (INL) is an ongoing, long-term program. This program, which began in 1949, includes hydrologic monitoring networks and investigative studies that describe the effects of waste disposal on water contained in the eastern Snake River Plain (ESRP) aquifer and the availability of water for long-term consumptive and industrial use. Interpretive reports documenting study findings are available to the U.S. Department of Energy (DOE) and its contractors; other Federal, State, and local agencies; private firms; and the public at https://id.water.usgs.gov/INL/Pubs/index.html. Information contained within these reports is crucial to the management and use of the aquifer by the INL and the State of Idaho. USGS geohydrologic studies and monitoring are done in cooperation with the DOE Idaho Operations Office.

  3. GPR survey, as one of the best geophysical methods for social and industrial needs

    Science.gov (United States)

    Chernov, Anatolii

    2016-04-01

    This paper is about ways and methods of applying non-invasive geophysical method - Ground penetrating radar (GPR) survey in different spheres of science, industry, social life and culture. Author would like to show that geological methods could be widely used for solving great variety of industrial, human safety and other problems. In that article, we take GPR survey as an example of such useful geophysical methods. It is a fact that investigation of near surface underground medium is important process, which influence on development of different spheres of science and social life: investigation of near surface geology (layering, spreading of rock types, identification of voids, etc.), hydrogeology (depth to water horizons, their thickness), preparation step for construction of roads and buildings (civil geology, engineering geology), investigation of cultural heritage (burial places, building remains,...), ecological investigations (land slides, variation in underground water level, etc.), glaciology. These tasks can be solved by geological methods, but as usual, geophysical survey takes a lot of time and energy (especially electric current and resistivity methods, seismic survey). Author claims that GPR survey can be performed faster than other geophysical surveys and results of GPR survey are informative enough to make proper conclusions. Some problems even cannot be solved without GPR. For example, identification of burial place (one of author's research objects): results of magnetic and electric resistivity tomography survey do not contain enough information to identify burial place, but according to anomalies on GPR survey radarograms, presence of burial place can be proven. Identification of voids and non-magnetic objects also hardly can be done by another non-invasive geophysics surveys and GPR is applicable for that purpose. GPR can be applied for monitoring of dangerous processes in geological medium under roads, buildings, parks and other places of human

  4. Survey of prevalence of overweight body condition in laboratory-housed cynomolgus macaques (Macaca fascicularis).

    Science.gov (United States)

    Bauer, Sharon A; Leslie, Ken E; Pearl, David L; Fournier, Jocelyn; Turner, Patricia V

    2010-07-01

    Excessive weight gain has been reported to occur in captive cynomolgus macaques with little to no change in diet. Overweight body condition can result in development of hyperglycemia and type 2 diabetes and should be avoided. The purpose of this survey was to assess the prevalence of overweight cynomolgus macaques in North American research facilities, including breeding colonies and short-term and long-term facilities, and to describe current methods used to assess body condition. The survey consisted of 51 questions covering animal population demographics, body weight and body condition scoring, feeding, and behavior. Voluntary participants included veterinarians and animal care managers. Respondents from 13 facilities completed the survey, and information was collected on 17,500 cynomolgus macaques. The majority of surveyed facilities housed juvenile and young adult macaques. The reported prevalence of overweight (greater than 10% of ideal body weight) animals ranged between 0% and 20% and reportedly was more frequent in animals younger than 10 y. Most facilities had weight reduction strategies in place. Despite these programs, a significant proportion of animals were reported as being overweight. The results of this survey demonstrate that most North American facilities housing cynomolgus macaques recognize the importance of tracking body condition regularly. However, implementing effective weight reduction programs may be difficult in captive housing environments. Because of the potential for adverse health effects, facilities should have a means of regularly tracking body weight as well as an action plan for managing overweight animals.

  5. Contamination of the Clinical Microbiology Laboratory with Vancomycin-Resistant Enterococci and Multidrug- Resistant Enterobacteriaceae: Implications for Hospital and Laboratory Workers

    Science.gov (United States)

    Collins, Susan M.; Hacek, Donna M.; Degen, Lisa A.; Wright, Marc O.; Noskin, Gary A.; Peterson, Lance R.

    2001-01-01

    We surveyed environmental surfaces in our clinical microbiology laboratory to determine the prevalence of vancomycin-resistant enterococci (VRE) and multidrug-resistant Enterobacteriaceae (MDRE) during a routine working day. From a total of 193 surfaces, VRE were present on 20 (10%) and MDRE were present on 4 (2%) of the surfaces tested. In a subsequent survey after routine cleaning, all of the 24 prior positive surfaces were found to be negative. Thus, those in the laboratory should recognize that many surfaces may be contaminated by resistant organisms during routine processing of patient specimens. PMID:11574615

  6. Equipment decontamination: A brief survey of the DOE complex

    International Nuclear Information System (INIS)

    Conner, C.; Chamberlain, D.B.; Chen, L.; Vandegrift, G.F.

    1995-03-01

    Deactivation at DOE facilities has left a tremendous amount of contaminated equipment behind. In-situ methods are needed to decontaminate the interiors of the equipment sufficiently to allow either free release or land disposal. A brief survey was completed of the DOE complex on their needs for equipment decontamination with in-situ technology to determine (1) the types of contamination problems within the DOE complex, (2) decontamination processes that are being used or are being developed within the DOE, and (3) the methods that are available to dispose of spent decontamination solutions. In addition, potential sites for testing decontamination methods were located. Based on the information obtained from these surveys, the Rocky Flats Plant and the Idaho National Engineering Laboratory appear to be best suited to complete the initial testing of the decontamination processes

  7. Blended learning within an undergraduate exercise physiology laboratory.

    Science.gov (United States)

    Elmer, Steven J; Carter, Kathryn R; Armga, Austin J; Carter, Jason R

    2016-03-01

    In physiological education, blended course formats (integration of face-to-face and online instruction) can facilitate increased student learning, performance, and satisfaction in classroom settings. There is limited evidence on the effectiveness of using blending course formats in laboratory settings. We evaluated the impact of blended learning on student performance and perceptions in an undergraduate exercise physiology laboratory. Using a randomized, crossover design, four laboratory topics were delivered in either a blended or traditional format. For blended laboratories, content was offloaded to self-paced video demonstrations (∼15 min). Laboratory section 1 (n = 16) completed blended laboratories for 1) neuromuscular power and 2) blood lactate, whereas section 2 (n = 17) completed blended laboratories for 1) maximal O2 consumption and 2) muscle electromyography. Both sections completed the same assignments (scored in a blinded manner using a standardized rubric) and practicum exams (evaluated by two independent investigators). Pre- and postcourse surveys were used to assess student perceptions. Most students (∼79%) watched videos for both blended laboratories. Assignment scores did not differ between blended and traditional laboratories (P = 0.62) or between sections (P = 0.91). Practicum scores did not differ between sections (both P > 0.05). At the end of the course, students' perceived value of the blended format increased (P learning key foundational content through video demonstrations before class greatly enhanced their learning of course material compared with a preassigned reading (94% vs. 78%, P Blended exercise physiology laboratories provided an alternative method for delivering content that was favorably perceived by students and did not compromise student performance. Copyright © 2016 The American Physiological Society.

  8. A Delphi Method Analysis to Create an Emergency Medicine Educational Patient Satisfaction Survey

    Directory of Open Access Journals (Sweden)

    Kory S. London

    2015-12-01

    Full Text Available Introduction: Feedback on patient satisfaction (PS as a means to monitor and improve performance in patient communication is lacking in residency training. A physician’s promotion, compensation and job satisfaction may be impacted by his individual PS scores, once he is in practice. Many communication and satisfaction surveys exist but none focus on the emergency department setting for educational purposes. The goal of this project was to create an emergency medicine-based educational PS survey with strong evidence for content validity. Methods: We used the Delphi Method (DM to obtain expert opinion via an iterative process of surveying. Questions were mined from four PS surveys as well as from group suggestion. The DM analysis determined the structure, content and appropriate use of the tool. The group used four-point Likert-type scales and Lynn’s criteria for content validity to determine relevant questions from the stated goals. Results: Twelve recruited experts participated in a series of seven surveys to achieve consensus. A 10-question, single-page survey with an additional page of qualitative questions and demographic questions was selected. Thirty one questions were judged to be relevant from an original 48-question list. Of these, the final 10 questions were chosen. Response rates for individual survey items was 99.5%. Conclusion: The DM produced a consensus survey with content validity evidence. Future work will be needed to obtain evidence for response process, internal structure and construct validity.

  9. Preparing investigation of methods for surveying tree seed demands among farmers in Tanzania

    DEFF Research Database (Denmark)

    Aabæk, Anders

    Insufficient seed supplies is often a major constraint on tree planting activities in developing countries. A central problem is to assess the actual demands for tree seed. This report shall, as a part of a PhD-study, prepare an investigation of different methods for surveying tree seed demands...... and preferences among private farmers in Tanzania. A framework for investigating seed demand and supply is outlined. The role of a national tree seed project in a seed supply sector is discussed and data requirements for strategy on seed procurement and tree improvement are outlined. Earlier surveys on seed...... demand pattern in Tanzania, Uganda and Nicaragua are discussed and a choice of strategy for an extensive survey of seed demand and supply in Tanzania is made. Different data collection methods and tools, e.g. quantitative and qualitative surveys and rapid rural appraisals, are described in detail...

  10. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  11. Approximate median regression for complex survey data with skewed response.

    Science.gov (United States)

    Fraser, Raphael André; Lipsitz, Stuart R; Sinha, Debajyoti; Fitzmaurice, Garrett M; Pan, Yi

    2016-12-01

    The ready availability of public-use data from various large national complex surveys has immense potential for the assessment of population characteristics using regression models. Complex surveys can be used to identify risk factors for important diseases such as cancer. Existing statistical methods based on estimating equations and/or utilizing resampling methods are often not valid with survey data due to complex survey design features. That is, stratification, multistage sampling, and weighting. In this article, we accommodate these design features in the analysis of highly skewed response variables arising from large complex surveys. Specifically, we propose a double-transform-both-sides (DTBS)'based estimating equations approach to estimate the median regression parameters of the highly skewed response; the DTBS approach applies the same Box-Cox type transformation twice to both the outcome and regression function. The usual sandwich variance estimate can be used in our approach, whereas a resampling approach would be needed for a pseudo-likelihood based on minimizing absolute deviations (MAD). Furthermore, the approach is relatively robust to the true underlying distribution, and has much smaller mean square error than a MAD approach. The method is motivated by an analysis of laboratory data on urinary iodine (UI) concentration from the National Health and Nutrition Examination Survey. © 2016, The International Biometric Society.

  12. Underground laboratories in Asia

    International Nuclear Information System (INIS)

    Lin, Shin Ted; Yue, Qian

    2015-01-01

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed

  13. Underground laboratories in Asia

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shin Ted, E-mail: linst@mails.phys.sinica.edu.tw [College of Physical Science and Technology, Sichuan University, Chengdu 610064 China (China); Yue, Qian, E-mail: yueq@mail.tsinghua.edu.cn [Key Laboratory of Particle and Radiation Imaging (Ministry of Education) and Department of Engineering Physics, Tsinghua University, Beijing 100084 China (China)

    2015-08-17

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed.

  14. Educational area for learning of optics and technologies: union of open laboratories of ideas, methods and practices (OLIMP)

    Science.gov (United States)

    Ivashchenko, Maksim; Bodrov, Kirill; Tolstoba, Nadezhda

    2016-09-01

    The paper deals with the concept of creating the union of Open Laboratories of Ideas, Methods and Practices (OLIMP). It describes the structure designed to simplify the relationship, such as business incubators, start-up accelerators, small innovative enterprises, fabrication laboratories and student centers. We consider their advantages and disadvantages for the specific audience of students and enthusiasts who do not have funding for their own projects. The experience of interaction between the Open Laboratories of Ideas, Methods and Practices and the Student Research Laboratory for Optical Engineering shows the relative impact of structures on each other and the value of using such interaction in the learning process. The paper also addresses issues such as: the motivation of students, enthusiasm for the direction the lab participants identify and maintain the initiatives, profiling in the design, scientific, commercial, social sphere.

  15. Comparing Coral Reef Survey Methods. Unesco Reports in Marine Science No. 21 Report of a Regional Unesco/UNEP Workshop on Coral Reef Survey Management and Assessment Methods in Asia and the Pacific (Phuket, Thailand, December 13-17, 1982).

    Science.gov (United States)

    United Nations Educational, Scientific, and Cultural Organization, Paris (France). Div. of Marine Sciences.

    This report includes nine papers prepared for a workshop on coral reef survey management and assessment methods in Asia and the Pacific. The papers are: "A Contrast in Methodologies between Surveying and Testing" (Charles Birkeland); "Coral Reef Survey Methods in the Andaman Sea" (Hansa Chansang); "A Review of Coral Reef…

  16. The former Semipalatinsk Test Site survey by field γ-spectrometry method

    International Nuclear Information System (INIS)

    Pakhomov, S.A.; Dubasov, Yu.V.; Biryukov, E.I.; Gavrilin, S.S.; Ilyin, L.I.

    2001-01-01

    Full text: Field γ-spectrometry method is the most productive method of getting an information on gamma-irradiating radionuclides contents in objects under survey. For many years the Radium Institute was the most active participant of works on radiation survey of the Semipalatinsk Test Site, field γ-spectrometry method including. In field γ-spectrometry method realization the existence of corresponding apparatus, and methodic software is supposed to be allowing to carry out both measurement, recording of γ-spectrometry energetic characteristics in field conditions and final treatment (using corresponding physical models) ensuring obtaining the information on radionuclides' contents. Different variants of such apparatus were developed and made at the Radium Institute. Under conditions of complex spectral structure and high intensity existence a portable variant of Ge(Li)-detector spectrometer fed by alkaline accumulators and allowing to record a spectrum at high load was elaborated. For walk γ-survey in common with the University two variants of portable spectrometers 'Skif-3' were elaborated: one of them with a standard scintillation detector on the base of Nal(Ti) crystal, having the size of 63x63 mm, and the other is an 'X-ray' detector of large dimension on the base of CsI crystal with a diameter of 165 mm, designated for soft gamma-irradiation registration, 241 Am including. During 8 hours of independent works 'Skif-3' is able to record into internal memory up to 100 spectra with an exposure up to 9999 s. At 10 min exposure in its sensitivity of 241 Am finding (10 Bq/kg) a spectrometer 'Skif-3' excels a portable spectrometer 'InSpector' (Canberra) working with the exposure of 1 hour. For automobile measurements a car spectrometer was elaborated fed. from car board supply and having four detectors based on NaI crystals with the dimensions 200x110 mm and total volume of about 121. For express treatment of a 'Skif-3' spectrometer scintillation spectra special

  17. Characterizing the Laboratory Market

    Energy Technology Data Exchange (ETDEWEB)

    Shehabi, Arman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); DeMates, Lauren [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathew, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sartor, Dale [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-04-11

    Laboratories are estimated to be 3-5 times more energy intensive than typical office buildings and offer significant opportunities for energy use reductions. Although energy intensity varies widely, laboratories are generally energy intensive due to ventilation requirements, the research instruments used, and other health and safety concerns. Because the requirements of laboratory facilities differ so dramatically from those of other buildings, a clear need exists for an initiative exclusively targeting these facilities. The building stock of laboratories in the United States span different economic sectors, include governmental and academic institution, and are often defined differently by different groups. Information on laboratory buildings is often limited to a small subsection of the total building stock making aggregate estimates of the total U.S. laboratories and their energy use challenging. Previous estimates of U.S. laboratory space vary widely owing to differences in how laboratories are defined and categorized. A 2006 report on fume hoods provided an estimate of 150,000 laboratories populating the U.S. based in part on interviews of industry experts, however, a 2009 analysis of the 2003 Commercial Buildings Energy Consumption Survey (CBECS) generated an estimate of only 9,000 laboratory buildings. This report draws on multiple data sources that have been evaluated to construct an understanding of U.S. laboratories across different sizes and markets segments. This 2016 analysis is an update to draft reports released in October and December 2016.

  18. Use of the National Committee for Clinical Laboratory Standards Guidelines for Disk Diffusion Susceptibility Testing in New York State Laboratories

    Science.gov (United States)

    Kiehlbauch, Julia A.; Hannett, George E.; Salfinger, Max; Archinal, Wendy; Monserrat, Catherine; Carlyn, Cynthia

    2000-01-01

    Accurate antimicrobial susceptibility testing is vital for patient care and surveillance of emerging antimicrobial resistance. The National Committee for Clinical Laboratory Standards (NCCLS) outlines generally agreed upon guidelines for reliable and reproducible results. In January 1997 we surveyed 320 laboratories participating in the New York State Clinical Evaluation Program for General Bacteriology proficiency testing. Our survey addressed compliance with NCCLS susceptibility testing guidelines for bacterial species designated a problem (Staphylococcus aureus and Enterococcus species) or fastidious (Streptococcus pneumoniae, Haemophilus influenzae, and Neisseria gonorrhoeae) organism. Specifically, we assessed compliance with guidelines for inoculum preparation, medium choice, number of disks per plate, and incubation conditions for disk diffusion tests. We also included length of incubation for S. aureus and Enterococcus species. We found overall compliance with the five characteristics listed above in 80 of 153 responding laboratories (50.6%) for S. aureus and 72 of 151 (47.7%) laboratories for Enterococcus species. The most common problem was an incubation time shortened to less than 24 h. Overall compliance with the first four characteristics was reported by 92 of 221 (41.6%) laboratories for S. pneumoniae, 49 of 163 (30.1%) laboratories for H. influenzae, and 11 of 77 (14.3%) laboratories for N. gonorrhoeae. Laboratories varied from NCCLS guidelines by placing an excess number of disks per plate. Laboratories also reported using alternative media for Enterococcus species, N. gonorrhoeae, and H. influenzae. This study demonstrates a need for education among clinical laboratories to increase compliance with NCCLS guidelines. PMID:10970381

  19. [Essential procedure and key methods for survey of traditional knowledge related to Chinese materia medica resources].

    Science.gov (United States)

    Cheng, Gong; Huang, Lu-qi; Xue, Da-yuan; Zhang, Xiao-bo

    2014-12-01

    The survey of traditional knowledge related to Chinese materia medica resources is the important component and one of the innovative aspects of the fourth national survey of the Chinese materia medica resources. China has rich traditional knowledge of traditional Chinese medicine (TCM) and the comprehensive investigation of TCM traditional knowledge aims to promote conservation and sustainable use of Chinese materia medica resources. Building upon the field work of pilot investigations, this paper introduces the essential procedures and key methods for conducting the survey of traditional knowledge related to Chinese materia medica resources. The essential procedures are as follows. First is the preparation phrase. It is important to review all relevant literature and provide training to the survey teams so that they have clear understanding of the concept of traditional knowledge and master key survey methods. Second is the field investigation phrase. When conducting field investigations, survey teams should identify the traditional knowledge holders by using the 'snowball method', record the traditional knowledge after obtaining prior informed concerned from the traditional knowledge holders. Researchers should fill out the survey forms provided by the Technical Specification of the Fourth National Survey of Chinese Materia Medica Resources. Researchers should pay particular attention to the scope of traditional knowledge and the method of inheriting the knowledge, which are the key information for traditional knowledge holders and potential users to reach mutual agreed terms to achieve benefit sharing. Third is the data compilation and analysis phrase. Researchers should try to compile and edit the TCM traditional knowledge in accordance with intellectual property rights requirements so that the information collected through the national survey can serve as the basic data for the TCM traditional knowledge database. The key methods of the survey include regional

  20. Biologic surveys for the Sandia National Laboratories, Coyote Canyon Test Complex, Kirtland Air Force Base, Albuquerque, New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, R.M. [4115 Allen Dr., Kingsville, TX (United States); Knight, P.J. [Marron and Associates, Inc., Corrales, NM (United States)

    1994-05-25

    This report provides results of a comprehensive biologic survey performed in Coyote Canyon Test Complex (CCTC), Sandia National Laboratories (SNL), Bernalillo County, New Mexico, which was conducted during the spring and summer of 1992 and 1993. CCTC is sited on land owned by the Department of Energy (DOE) and Kirtland Air Force Base and managed by SNL. The survey covered 3,760 acres of land, most of which is rarely disturbed by CCTC operations. Absence of grazing by livestock and possibly native ungulates, and relative to the general condition of private range lands throughout New Mexico, and relative to other grazing lands in central New Mexico. Widely dispersed, low intensity use by SNL as well as prohibition of grazing has probably contributed to abundance of special status species such as grama grass cactus within the CCTC area. This report evaluates threatened and endangered species found in the area, as well as comprehensive assessment of biologic habitats. Included are analyses of potential impacts and mitigative measures designed to reduce or eliminate potential impacts. Included is a summary of CCTC program and testing activities.

  1. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    Science.gov (United States)

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  2. Mobile phones are a viable option for surveying young Australian women: a comparison of two telephone survey methods

    Directory of Open Access Journals (Sweden)

    Liu Bette

    2011-11-01

    Full Text Available Abstract Background Households with fixed-line telephones have decreased while mobile (cell phone ownership has increased. We therefore sought to examine the feasibility of recruiting young women for a national health survey through random digit dialling mobile phones. Methods Two samples of women aged 18 to 39 years were surveyed by random digit dialling fixed and mobile numbers. We compared participation rates and responses to a questionnaire between women surveyed by each contact method. Results After dialling 5,390 fixed-lines and 3,697 mobile numbers, 140 and 128 women were recruited respectively. Among women contacted and found to be eligible, participation rates were 74% for fixed-lines and 88% for mobiles. Taking into account calls to numbers where eligibility was unknown (e.g. unanswered calls the estimated response rates were 54% and 45% respectively. Of women contacted by fixed-line, 97% reported having a mobile while 61% of those contacted by mobile reported having a fixed-line at home. After adjusting for age, there were no significant differences between mobile-only and fixed-line responders with respect to education, residence, and various health behaviours; however compared to those with fixed-lines, mobile-only women were more likely to identify as Indigenous (OR 4.99, 95%CI 1.52-16.34 and less likely to live at home with their parents (OR 0.09, 95%CI 0.03-0.29. Conclusions Random digit dialling mobile phones to conduct a health survey in young Australian women is feasible, gives a comparable response rate and a more representative sample than dialling fixed-lines only. Telephone surveys of young women should include mobile dialling.

  3. Training practices of cell processing laboratory staff: analysis of a survey by the Alliance for Harmonization of Cellular Therapy Accreditation.

    Science.gov (United States)

    Keever-Taylor, Carolyn A; Slaper-Cortenbach, Ineke; Celluzzi, Christina; Loper, Kathy; Aljurf, Mahmoud; Schwartz, Joseph; Mcgrath, Eoin; Eldridge, Paul

    2015-12-01

    Methods for processing products used for hematopoietic progenitor cell (HPC) transplantation must ensure their safety and efficacy. Personnel training and ongoing competency assessment is critical to this goal. Here we present results from a global survey of methods used by a diverse array of cell processing facilities for the initial training and ongoing competency assessment of key personnel. The Alliance for Harmonisation of Cellular Therapy Accreditation (AHCTA) created a survey to identify facility type, location, activity, personnel, and methods used for training and competency. A survey link was disseminated through organizations represented in AHCTA to processing facilities worldwide. Responses were tabulated and analyzed as a percentage of total responses and as a percentage of response by region group. Most facilities were based at academic medical centers or hospitals. Facilities with a broad range of activity, product sources and processing procedures were represented. Facilities reported using a combination of training and competency methods. However, some methods predominated. Cellular sources for training differed for training versus competency and also differed based on frequency of procedures performed. Most facilities had responsibilities for procedures in addition to processing for which training and competency methods differed. Although regional variation was observed, training and competency requirements were generally consistent. Survey data showed the use of a variety of training and competency methods but some methods predominated, suggesting their utility. These results could help new and established facilities in making decisions for their own training and competency programs. Copyright © 2015 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  4. 3-Dimensional and Interactive Istanbul University Virtual Laboratory Based on Active Learning Methods

    Science.gov (United States)

    Ince, Elif; Kirbaslar, Fatma Gulay; Yolcu, Ergun; Aslan, Ayse Esra; Kayacan, Zeynep Cigdem; Alkan Olsson, Johanna; Akbasli, Ayse Ceylan; Aytekin, Mesut; Bauer, Thomas; Charalambis, Dimitris; Gunes, Zeliha Ozsoy; Kandemir, Ceyhan; Sari, Umit; Turkoglu, Suleyman; Yaman, Yavuz; Yolcu, Ozgu

    2014-01-01

    The purpose of this study is to develop a 3-dimensional interactive multi-user and multi-admin IUVIRLAB featuring active learning methods and techniques for university students and to introduce the Virtual Laboratory of Istanbul University and to show effects of IUVIRLAB on students' attitudes on communication skills and IUVIRLAB. Although there…

  5. Infection control practice in private dental laboratories in Riyadh

    International Nuclear Information System (INIS)

    AlKheraif, Abdulaziz A; Mobarak, Fahmy A

    2008-01-01

    In view of the risk of infection of dental health care workers and patients, interruption of possible chains of infection is to be demanded. The objective of this study was to assess infection control practice in private dental laboratories in Riyadh City, Kingdom of Saudi Arabia. The study was conducted on thirty-two private dental laboratories in Riyadh City regarding infection control practiced by these laboratories. The instrument of the study consisted of ten open-ended questions that were asked from the laboratories directors. A large percentage of the surveyed laboratories (87.5 %) did not implement any infection control protocol during their practice. The mean number of impressions received per week was 16. Most of the surveyed laboratories (90.6 %) had no way of communication with the clinics regarding the disinfection procedures. The results indicated that 62.5 % of the laboratories reported that they were aware that they may get infection from non-disinfected items. Only a small percentage (6.2%) of the laboratories added disinfecting agent to pumice slurry. Wearing laboratory coats was reported by 75% of the laboratory workers. The use of gloves during work was reported by 59.3% of the laboratories while 56.2% reported the use protective eyewear. Only 21.8% of the laboratories use face masks during work. Construction of infection control manuals that contain updated and recommended guidelines to ensure aseptic practice in private dental laboratories is highly recommended. Also, a way of communication between dentists and dental technicians regarding disinfection of laboratory items should be strongly encouraged. (author)

  6. Electronic laboratory quality assurance program: A method of enhancing the prosthodontic curriculum and addressing accreditation standards.

    Science.gov (United States)

    Moghadam, Marjan; Jahangiri, Leila

    2015-08-01

    An electronic quality assurance (eQA) program was developed to replace a paper-based system and to address standards introduced by the Commission on Dental Accreditation (CODA) and to improve educational outcomes. This eQA program provides feedback to predoctoral dental students on prosthodontic laboratory steps at New York University College of Dentistry. The purpose of this study was to compare the eQA program of performing laboratory quality assurance with the former paper-based format. Fourth-year predoctoral dental students (n=334) who experienced both the paper-based and the electronic version of the quality assurance program were surveyed about their experiences. Additionally, data extracted from the eQA program were analyzed to identify areas of weakness in the curriculum. The study findings revealed that 73.8% of the students preferred the eQA program to the paper-based version. The average number of treatments that did not pass quality assurance standards was 119.5 per month. This indicated a 6.34% laboratory failure rate. Further analysis of these data revealed that 62.1% of the errors were related to fixed prosthodontic treatment, 27.9% to partial removable dental prostheses, and 10% to complete removable dental prostheses in the first 18 months of program implementation. The eQA program was favored by dental students who have experienced both electronic and paper-based versions of the system. Error type analysis can yield the ability to create customized faculty standardization sessions and refine the didactic and clinical teaching of the predoctoral students. This program was also able to link patient care activity with the student's laboratory activities, thus addressing the latest requirements of the CODA regarding the competence of graduates in evaluating laboratory work related to their patient care. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Meeting report: discussions and preliminary findings on extracellular RNA measurement methods from laboratories in the NIH Extracellular RNA Communication Consortium

    Directory of Open Access Journals (Sweden)

    Louise C. Laurent

    2015-08-01

    Full Text Available Extracellular RNAs (exRNAs have been identified in all tested biofluids and have been associated with a variety of extracellular vesicles, ribonucleoprotein complexes and lipoprotein complexes. Much of the interest in exRNAs lies in the fact that they may serve as signalling molecules between cells, their potential to serve as biomarkers for prediction and diagnosis of disease and the possibility that exRNAs or the extracellular particles that carry them might be used for therapeutic purposes. Among the most significant bottlenecks to progress in this field is the lack of robust and standardized methods for collection and processing of biofluids, separation of different types of exRNA-containing particles and isolation and analysis of exRNAs. The Sample and Assay Standards Working Group of the Extracellular RNA Communication Consortium is a group of laboratories funded by the U.S. National Institutes of Health to develop such methods. In our first joint endeavour, we held a series of conference calls and in-person meetings to survey the methods used among our members, placed them in the context of the current literature and used our findings to identify areas in which the identification of robust methodologies would promote rapid advancements in the exRNA field.

  8. THE METHODS OF LABORATORY DIAGNOSTICS OF UROGENITAL INFECTIONS ASSOCIATED WITH MYCOPLASMA HOMINIS AND UREAPLASMA SPP.

    Directory of Open Access Journals (Sweden)

    O. V. Zarucheynova

    2014-01-01

    Full Text Available Wide distribution of urogenital mycoplasmas in the population, the high frequency of carrier state and a long asymptomatic course of disease, the lack of specific clinical symptoms making the diagnosis impossible without using of special laboratory tests. The review focuses on indications for mycoplasma infection screening and for an appointmentof antibiotic therapy. The most commonly used laboratory diagnostic methods of urogenital infections, associated with Mycoplasma hominis and Ureaplasma spp., with their characteristics, advantages and disadvantages are described.

  9. Optimized star sensors laboratory calibration method using a regularization neural network.

    Science.gov (United States)

    Zhang, Chengfen; Niu, Yanxiong; Zhang, Hao; Lu, Jiazhen

    2018-02-10

    High-precision ground calibration is essential to ensure the performance of star sensors. However, the complex distortion and multi-error coupling have brought great difficulties to traditional calibration methods, especially for large field of view (FOV) star sensors. Although increasing the complexity of models is an effective way to improve the calibration accuracy, it significantly increases the demand for calibration data. In order to achieve high-precision calibration of star sensors with large FOV, a novel laboratory calibration method based on a regularization neural network is proposed. A multi-layer structure neural network is designed to represent the mapping of the star vector and the corresponding star point coordinate directly. To ensure the generalization performance of the network, regularization strategies are incorporated into the net structure and the training algorithm. Simulation and experiment results demonstrate that the proposed method can achieve high precision with less calibration data and without any other priori information. Compared with traditional methods, the calibration error of the star sensor decreased by about 30%. The proposed method can satisfy the precision requirement for large FOV star sensors.

  10. Safety in the Chemical Laboratory. Epidemiology of Accidents in Academic Chemistry Laboratories, Part 2. Accident Intervention Study, Legal Aspects, and Observations.

    Science.gov (United States)

    Hellmann, Margaret A.; And Others

    1986-01-01

    Reports on a chemistry laboratory accident intervention study conducted throughout the state of Colorado. Addresses the results of an initial survey of institutions of higher learning. Discusses some legal aspects concerning academic chemistry accidents. Provides some observations about academic chemistry laboratory accidents on the whole. (TW)

  11. Laboratory development of methods for centralized treatment of liquid low-level waste at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Arnold, W.D.; Bostick, D.T.; Burgess, M.W.; Taylor, P.A.; Perona, J.J.; Kent, T.E.

    1994-10-01

    Improved centralized treatment methods are needed in the management of liquid low-level waste (LLLW) at Oak Ridge National Laboratory (ORNL). LLLW, which usually contains radioactive contaminants at concentrations up to millicurie-per-liter levels, has accumulated in underground storage tanks for over 10 years and has reached a volume of over 350,000 gal. These wastes have been collected since 1984 and are a complex mixture of wastes from past nuclear energy research activities. The waste is a highly alkaline 4-5 M NaNO 3 solution with smaller amounts of other salts. This type of waste will continue to be generated as a consequence of future ORNL research programs. Future LLLW (referred to as newly generated LLLW or NGLLLW) is expected to a highly alkaline solution of sodium carbonate and sodium hydroxide with a smaller concentration of sodium nitrate. New treatment facilities are needed to improve the manner in which these wastes are managed. These facilities must be capable of separating and reducing the volume of radioactive contaminants to small stable waste forms. Treated liquids must meet criteria for either discharge to the environment or solidification for onsite disposal. Laboratory testing was performed using simulated waste solutions prepared using the available characterization information as a basis. Testing was conducted to evaluate various methods for selective removal of the major contaminants. The major contaminants requiring removal from Melton Valley Storage Tank liquids are 90 Sr and 137 Cs. Principal contaminants in NGLLLW are 9O Sr, 137 Cs, and 106 Ru. Strontium removal testing began with literature studies and scoping tests with several ion-exchange materials and sorbents

  12. Survey: interpolation methods for whole slide image processing.

    Science.gov (United States)

    Roszkowiak, L; Korzynska, A; Zak, J; Pijanowska, D; Swiderska-Chadaj, Z; Markiewicz, T

    2017-02-01

    Evaluating whole slide images of histological and cytological samples is used in pathology for diagnostics, grading and prognosis . It is often necessary to rescale whole slide images of a very large size. Image resizing is one of the most common applications of interpolation. We collect the advantages and drawbacks of nine interpolation methods, and as a result of our analysis, we try to select one interpolation method as the preferred solution. To compare the performance of interpolation methods, test images were scaled and then rescaled to the original size using the same algorithm. The modified image was compared to the original image in various aspects. The time needed for calculations and results of quantification performance on modified images were also compared. For evaluation purposes, we used four general test images and 12 specialized biological immunohistochemically stained tissue sample images. The purpose of this survey is to determine which method of interpolation is the best to resize whole slide images, so they can be further processed using quantification methods. As a result, the interpolation method has to be selected depending on the task involving whole slide images. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  13. cp-R, an interface the R programming language for clinical laboratory method comparisons.

    Science.gov (United States)

    Holmes, Daniel T

    2015-02-01

    Clinical scientists frequently need to compare two different bioanalytical methods as part of assay validation/monitoring. As a matter necessity, regression methods for quantitative comparison in clinical chemistry, hematology and other clinical laboratory disciplines must allow for error in both the x and y variables. Traditionally the methods popularized by 1) Deming and 2) Passing and Bablok have been recommended. While commercial tools exist, no simple open source tool is available. The purpose of this work was to develop and entirely open-source GUI-driven program for bioanalytical method comparisons capable of performing these regression methods and able to produce highly customized graphical output. The GUI is written in python and PyQt4 with R scripts performing regression and graphical functions. The program can be run from source code or as a pre-compiled binary executable. The software performs three forms of regression and offers weighting where applicable. Confidence bands of the regression are calculated using bootstrapping for Deming and Passing Bablok methods. Users can customize regression plots according to the tools available in R and can produced output in any of: jpg, png, tiff, bmp at any desired resolution or ps and pdf vector formats. Bland Altman plots and some regression diagnostic plots are also generated. Correctness of regression parameter estimates was confirmed against existing R packages. The program allows for rapid and highly customizable graphical output capable of conforming to the publication requirements of any clinical chemistry journal. Quick method comparisons can also be performed and cut and paste into spreadsheet or word processing applications. We present a simple and intuitive open source tool for quantitative method comparison in a clinical laboratory environment. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Study on method of dose estimation for the Dual-moderated neutron survey meter

    International Nuclear Information System (INIS)

    Zhou, Bo; Li, Taosheng; Xu, Yuhai; Gong, Cunkui; Yan, Qiang; Li, Lei

    2013-01-01

    In order to study neutron dose measurement in high energy radiation field, a Dual-moderated survey meter in the range from 1 keV to 300 MeV mean energies spectra has been developed. Measurement results of some survey meters depend on the neutron spectra characteristics in different neutron radiation fields, so the characteristics of the responses to various neutron spectra should be studied in order to get more reasonable dose. In this paper the responses of the survey meter were calculated under different neutron spectra data from IAEA of Technical Reports Series No. 318 and other references. Finally one dose estimation method was determined. The range of the reading per H*(10) for the method estimated is about 0.7–1.6 for the neutron mean energy range from 50 keV to 300 MeV. -- Highlights: • We studied a novel high energy neutron survey meter. • Response characteristics of the survey meter were calculated by using a series of neutron spectra. • One significant advantage of the survey meter is that it can provide mean energy of radiation field. • Dose estimate deviation can be corrected. • The range of corrected reading per H*(10) is about 0.7–1.6 for the neutron fluence mean energy range from 0.05 MeV to 300 MeV

  15. Methods of radon measurement and devices

    International Nuclear Information System (INIS)

    Miles, J.

    2004-01-01

    The following topics and instrumentation are discussed: The quantity to be measured; Active measurement methods (scintillation cells, ionisation chambers, electrostatic collection of decay products); Passive measurement methods (charcoal detectors; electret ion chambers; etched track detectors); and Detector considerations for large-scale surveys ('always on' or 'switchable' detectors?; response to radon-220; avoidance of electrostatic effects; quality assurance for passive radon detectors; quality control within the laboratory; external quality assurance; detectors need to be easily deliverable). It is concluded that the ideal detector for large scale surveys of radon in houses is a small, closed detector in a conducting holder which excludes radon-220, supported by rigorous quality assurance procedures. (P.A.)

  16. [Trend survey of ocular infections with bacteria at Toyama University Hospital over the past six years--from the standpoint of laboratory examination].

    Science.gov (United States)

    Kubota, Tomomi; Hayashi, Shirou; Niimi, Hideki; Kitajima, Isao

    2012-07-01

    Specimens of bacterial ocular infections are frequently received in the clinical laboratory. However, a comprehensive trend survey of ocular infections with bacteria is very rare. Our objective is to understand the current tendency of ocular infections with bacteria in patients at Toyama University Hospital from the standpoint of laboratory examination. We studied 263 cases of ocular infection with bacteria diagnosed at Toyama University Hospital from January 2006 to December 2011. 123 were male and 140 were female, with a mean age of 61.2(0-98) years. Specimens were subjected to direct microscopy and culture. Cultures were positive in 174(66.2%) patients. The most common bacterial isolate was Staphylococcus (28.1%), followed by Corynebacterium (19.3%), Streptococcus (9.3%), and Propionibacterium (8.6%). MRSA accounted for 18.8% of all S. aureus isolates, and has increased in recent years. The number of bacteria detected was larger in March, June, July, August, and October. Age distribution indicated that around 70% of bacterial isolates were detected from patients over 60 years old. The most common specimen of ocular infections with bacteria was eye discharge (detection rate; 87.8%), followed by corneal scraping(41%), aqueous humor (19%), and vitreous body (27%). Nearly 80% of bacterial isolates were detected from patients with keratitis, endophthalmitis, dacryocystitis, and conjunctivitis. As for the disease specific detection rate, endophthalmitis was very low (38.3%). The detection rate by years indicated that the way doctors pick up the specimens greatly affects the detection rate. Based on this survey, we need close cooperation with medical doctors concerning laboratory examination in ocular infection with bacteria, and we must improve the detection sensitivity of specimens from patients with endophthalmitis.

  17. A Survey on Chinese Scholars' Adoption of Mixed Methods

    Science.gov (United States)

    Zhou, Yuchun

    2018-01-01

    Since the 1980s when mixed methods emerged as "the third research methodology", it was widely adopted in Western countries. However, inadequate literature revealed how this methodology was accepted by scholars in Asian countries, such as China. Therefore, this paper used a quantitative survey to investigate Chinese scholars' perceptions…

  18. Expanding Clinical Laboratory Tobacco Product Evaluation Methods to Loose-leaf Tobacco Vaporizers

    Science.gov (United States)

    Lopez, Alexa A.; Hiler, Marzena; Maloney, Sarah; Eissenberg, Thomas; Breland, Alison

    2016-01-01

    Background Novel tobacco products entering the US market include electronic cigarettes (ECIGs) and products advertised to “heat, not burn” tobacco. There is a growing literature regarding the acute effects of ECIGs. Less is known about “heat, not burn” products. This study’s purpose was to expand existing clinical laboratory methods to examine, in cigarette smokers, the acute effects of a “heat, not burn” “loose-leaf tobacco vaporizer” (LLTV). Methods Plasma nicotine and breath carbon monoxide (CO) concentration and tobacco abstinence symptom severity were measured before and after two 10-puff (30-sec interpuff interval) product use bouts separated by 60 minutes. LLTV effects were compared to participants’ own brand (OB) cigarettes and an ECIG (3.3 V; 1.5 Ohm; 18 mg/ml nicotine). Results Relative to OB, LLTV increased plasma nicotine concentration to a lesser degree, did not increase CO, and appeared to not reduce abstinence symptoms as effectively. Relative to ECIG, LLTV nicotine and CO delivery and abstinence symptom suppression did not differ. Participants reported that both the LLTV and ECIG were significantly less satisfying than OB. Conclusions Results demonstrate that LLTVs are capable of delivering nicotine and suppressing tobacco abstinence symptoms partially; acute effects of these products can be evaluated using existing clinical laboratory methods. Results can inform tobacco product regulation and may be predictive of the extent that these products have the potential to benefit or harm overall public health. PMID:27768968

  19. Gray whale survey and sightings ranging from California to Kodiak Island, Alaska conducted by the National Marine Mammal Laboratory from 1993-07-05 to 2014-10-24 (NCEI Accession 0145636)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Gray whale (Eschrichtius robustus) survey and sightings data from 1993 - 2014 collected by the National Marine Mammal Laboratories' California Current Ecosystem...

  20. The use of virtual laboratories and other web-based tools in a drug assay course.

    Science.gov (United States)

    Dunham, Marissa Waldman; Ghirtis, Konstantine; Beleh, Mustapha

    2012-06-18

    To determine students' perceptions of and performance in a drug assay laboratory course after the addition of Web-based multimedia tools. Video modules and other Web-based tools to deliver instructions and emulate the laboratory set up for experiments were implemented in 2005 to improve student preparation for laboratory sessions and eliminate the need for graduate students to present instructions live. Data gathered from quizzes, final examinations, and post-course surveys administered over 6 years were analyzed. Students' scores on online quizzes after implementation of the virtual laboratories reflected improved student understanding and preparation. Students' perception of the course improved significantly after the introduction of the tools and the new teaching model. Implementation of an active-learning model in a laboratory course led to improvement in students' educational experience and satisfaction. Additional benefits included improved resource use, student exposure to a variety of educational methods, and having a highly structured laboratory format that reduced inconsistencies in delivered instructions.

  1. Integrated management system best practices in radioecological laboratories

    International Nuclear Information System (INIS)

    Carvalho, Claudia Aparecida Zerbinatti de

    2010-01-01

    The research aims to study the best practices to support a conceptual proposal for IMS - Integrated Management System (quality, environment, safety and health) applicable to Radioecology laboratories. The research design is organized into the following steps: in a first step, it was developed the bibliographic and documentary research in IMS, survey and study of standards (QMS ISO 9000 (2005), ISO 9001 (2008), ISO 9004 (2000), EMS ISO 14001 (2004) and OHSMS OHSAS 18001 (2007) and OHSAS 18002 (2008)), identification and characterization of processes in Radioecology Laboratories and study of best practices methodology and benchmarking; in the second stage of the research it was developed a case study (qualitative research, with questionnaires via e-mail and interviews, when possible), preceded by a survey and selection of international and national radioecology laboratories and then these laboratories were contacted and some of them agreed to participate in this research; in the third stage of the research it was built the framework of best practices that showed results that could support the conceptual proposal for the IMS Radioecology Laboratory; the fourth and final stage of research consisted in the construction of the proposed conceptual framework of SGI for Radioecology Laboratory, being then achieved the initial objective of the research. (author)

  2. Comparing two survey methods of measuring health-related indicators: Lot Quality Assurance Sampling and Demographic Health Surveys.

    Science.gov (United States)

    Anoke, Sarah C; Mwai, Paul; Jeffery, Caroline; Valadez, Joseph J; Pagano, Marcello

    2015-12-01

    Two common methods used to measure indicators for health programme monitoring and evaluation are the demographic and health surveys (DHS) and lot quality assurance sampling (LQAS); each one has different strengths. We report on both methods when utilised in comparable situations. We compared 24 indicators in south-west Uganda, where data for prevalence estimations were collected independently for the two methods in 2011 (LQAS: n = 8876; DHS: n = 1200). Data were stratified (e.g. gender and age) resulting in 37 comparisons. We used a two-sample two-sided Z-test of proportions to compare both methods. The average difference between LQAS and DHS for 37 estimates was 0.062 (SD = 0.093; median = 0.039). The average difference among the 21 failures to reject equality of proportions was 0.010 (SD = 0.041; median = 0.009); among the 16 rejections, it was 0.130 (SD = 0.010, median = 0.118). Seven of the 16 rejections exhibited absolute differences of 0.10 and 0.20 (mean = 0.261, SD = 0.083). There is 75.7% agreement across the two surveys. Both methods yield regional results, but only LQAS provides information at less granular levels (e.g. the district level) where managerial action is taken. The cost advantage and localisation make LQAS feasible to conduct more frequently, and provides the possibility for real-time health outcomes monitoring. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  3. Using Self-Explanations in the Laboratory to Connect Theory and Practice: The Decision/ Explanation/Observation/Inference Writing Method

    Science.gov (United States)

    Van Duzor, Andrea Gay

    2016-01-01

    While many faculty seek to use student-centered, inquiry-based approaches in teaching laboratories, transitioning from traditional to inquiry instruction can be logistically challenging. This paper outlines use of a laboratory notebook and report writing-to-learn method that emphasizes student self-explanations of procedures and outcomes,…

  4. A new method of measuring gravitational acceleration in an undergraduate laboratory program

    Science.gov (United States)

    Wang, Qiaochu; Wang, Chang; Xiao, Yunhuan; Schulte, Jurgen; Shi, Qingfan

    2018-01-01

    This paper presents a high accuracy method to measure gravitational acceleration in an undergraduate laboratory program. The experiment is based on water in a cylindrical vessel rotating about its vertical axis at a constant speed. The water surface forms a paraboloid whose focal length is related to rotational period and gravitational acceleration. This experimental setup avoids classical source errors in determining the local value of gravitational acceleration, so prevalent in the common simple pendulum and inclined plane experiments. The presented method combines multiple physics concepts such as kinematics, classical mechanics and geometric optics, offering the opportunity for lateral as well as project-based learning.

  5. Mobile autonomous robot for radiological surveys

    International Nuclear Information System (INIS)

    Dudar, A.M.; Wagner, D.G.; Teese, G.D.

    1992-01-01

    The robotics development group at the Savannah River Laboratory (SRL) is developing a mobile autonomous robot that performs radiological surveys of potentially contaminated floors. The robot is called SIMON, which stands for Semi-Intelligent Mobile Observing Navigator. Certain areas of SRL are classified as radiologically controlled areas (RCAs). In an RCA, radioactive materials are frequently handled by workers, and thus, the potential for contamination is ever present. Current methods used for floor radiological surveying includes labor-intensive manual scanning or random smearing of certain floor locations. An autonomous robot such as SIMON performs the surveying task in a much more efficient manner and will track down contamination before it is contacted by humans. SIMON scans floors at a speed of 1 in./s and stops and alarms upon encountering contamination. Its environment is well defined, consisting of smooth building floors with wide corridors. The kind of contaminations that SIMON is capable of detecting are alpha and beta-gamma. The contamination levels of interest are low to moderate

  6. Methods of practice and guidelines for using survey-grade global navigation satellite systems (GNSS) to establish vertical datum in the United States Geological Survey

    Science.gov (United States)

    Rydlund, Jr., Paul H.; Densmore, Brenda K.

    2012-01-01

    Geodetic surveys have evolved through the years to the use of survey-grade (centimeter level) global positioning to perpetuate and post-process vertical datum. The U.S. Geological Survey (USGS) uses Global Navigation Satellite Systems (GNSS) technology to monitor natural hazards, ensure geospatial control for climate and land use change, and gather data necessary for investigative studies related to water, the environment, energy, and ecosystems. Vertical datum is fundamental to a variety of these integrated earth sciences. Essentially GNSS surveys provide a three-dimensional position x, y, and z as a function of the North American Datum of 1983 ellipsoid and the most current hybrid geoid model. A GNSS survey may be approached with post-processed positioning for static observations related to a single point or network, or involve real-time corrections to provide positioning "on-the-fly." Field equipment required to facilitate GNSS surveys range from a single receiver, with a power source for static positioning, to an additional receiver or network communicated by radio or cellular for real-time positioning. A real-time approach in its most common form may be described as a roving receiver augmented by a single-base station receiver, known as a single-base real-time (RT) survey. More efficient real-time methods involving a Real-Time Network (RTN) permit the use of only one roving receiver that is augmented to a network of fixed receivers commonly known as Continually Operating Reference Stations (CORS). A post-processed approach in its most common form involves static data collection at a single point. Data are most commonly post-processed through a universally accepted utility maintained by the National Geodetic Survey (NGS), known as the Online Position User Service (OPUS). More complex post-processed methods involve static observations among a network of additional receivers collecting static data at known benchmarks. Both classifications provide users

  7. Effective Laboratory Method of Chromite Content Estimation in Reclaimed Sands

    Directory of Open Access Journals (Sweden)

    Ignaszak Z.

    2016-09-01

    Full Text Available The paper presents an original method of measuring the actual chromite content in the circulating moulding sand of foundry. This type of material is applied for production of moulds. This is the case of foundry which most frequently perform heavy casting in which for the construction of chemical hardening mould is used, both the quartz sand and chromite sand. After the dry reclamation of used moulding sand, both types of sands are mixed in various ratios resulting that in reclaimed sand silos, the layers of varying content of chromite in mixture are observed. For chromite recuperation from the circulating moulding sand there are applied the appropriate installations equipped with separate elements generating locally strong magnetic field. The knowledge of the current ratio of chromite and quartz sand allows to optimize the settings of installation and control of the separation efficiency. The arduous and time-consuming method of determining the content of chromite using bromoform liquid requires operational powers and precautions during using this toxic liquid. It was developed and tested the new, uncomplicated gravimetric laboratory method using powerful permanent magnets (neodymium. The method is used in the production conditions of casting for current inspection of chromite quantity in used sand in reclamation plant.

  8. Don't spin the pen: two alternative methods for second-stage sampling in urban cluster surveys

    Directory of Open Access Journals (Sweden)

    Rose Angela MC

    2007-06-01

    Full Text Available Abstract In two-stage cluster surveys, the traditional method used in second-stage sampling (in which the first household in a cluster is selected is time-consuming and may result in biased estimates of the indicator of interest. Firstly, a random direction from the center of the cluster is selected, usually by spinning a pen. The houses along that direction are then counted out to the boundary of the cluster, and one is then selected at random to be the first household surveyed. This process favors households towards the center of the cluster, but it could easily be improved. During a recent meningitis vaccination coverage survey in Maradi, Niger, we compared this method of first household selection to two alternatives in urban zones: 1 using a superimposed grid on the map of the cluster area and randomly selecting an intersection; and 2 drawing the perimeter of the cluster area using a Global Positioning System (GPS and randomly selecting one point within the perimeter. Although we only compared a limited number of clusters using each method, we found the sampling grid method to be the fastest and easiest for field survey teams, although it does require a map of the area. Selecting a random GPS point was also found to be a good method, once adequate training can be provided. Spinning the pen and counting households to the boundary was the most complicated and time-consuming. The two methods tested here represent simpler, quicker and potentially more robust alternatives to spinning the pen for cluster surveys in urban areas. However, in rural areas, these alternatives would favor initial household selection from lower density (or even potentially empty areas. Bearing in mind these limitations, as well as available resources and feasibility, investigators should choose the most appropriate method for their particular survey context.

  9. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    Science.gov (United States)

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  10. Determination of the scattered radiation at the Neutron Calibration Laboratory of IPEN using the shadow cone method

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Tallyson S.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Freitas, Bruno M. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Fonseca, Evaldo S.; Pereira, Walsan W., E-mail: talvarenga@ipen.br, E-mail: lcaldas@ipen.br, E-mail: bfreitas@con.ufrj.br, E-mail: walsan@ird.gov.br, E-mail: evaldo@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Because of the increase in the demand for the calibration of neutron detectors, there is a need for new calibration services. In this context, the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (IPEN), São Paulo, which already offers calibration services of radiation detectors with standard X, gamma, beta and alpha beams, has recently projected a new test laboratory for neutron detectors. This work evaluated the contribution of dispersed neutron radiation in this laboratory, using the cone shadow method and a Bonner sphere spectrometer to take the measurements at a distance of 100 cm from the neutron source. The dosimetric quantities H⁎(10) and H⁎(10) were obtained at the laboratory, allowing the calibration of detectors. (author)

  11. Determination of the scattered radiation at the Neutron Calibration Laboratory of IPEN using the shadow cone method

    International Nuclear Information System (INIS)

    Alvarenga, Tallyson S.; Caldas, Linda V.E.; Freitas, Bruno M.

    2017-01-01

    Because of the increase in the demand for the calibration of neutron detectors, there is a need for new calibration services. In this context, the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (IPEN), São Paulo, which already offers calibration services of radiation detectors with standard X, gamma, beta and alpha beams, has recently projected a new test laboratory for neutron detectors. This work evaluated the contribution of dispersed neutron radiation in this laboratory, using the cone shadow method and a Bonner sphere spectrometer to take the measurements at a distance of 100 cm from the neutron source. The dosimetric quantities H⁎(10) and H⁎(10) were obtained at the laboratory, allowing the calibration of detectors. (author)

  12. Streamlining and automation of radioanalytical methods at a commercial laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, J.T.; Dillard, J.W. [IT Corp., Knoxville, TN (United States)

    1993-12-31

    Through the careful planning and design of laboratory facilities and incorporation of modern instrumentation and robotics systems, properly trained and competent laboratory associates can efficiently and safely handle radioactive and mixed waste samples. This paper addresses the potential improvements radiochemistry and mixed waste laboratories can achieve utilizing robotics for automated sample analysis. Several examples of automated systems for sample preparation and analysis will be discussed.

  13. Streamlining and automation of radioanalytical methods at a commercial laboratory

    International Nuclear Information System (INIS)

    Harvey, J.T.; Dillard, J.W.

    1993-01-01

    Through the careful planning and design of laboratory facilities and incorporation of modern instrumentation and robotics systems, properly trained and competent laboratory associates can efficiently and safely handle radioactive and mixed waste samples. This paper addresses the potential improvements radiochemistry and mixed waste laboratories can achieve utilizing robotics for automated sample analysis. Several examples of automated systems for sample preparation and analysis will be discussed

  14. 21 CFR 111.320 - What requirements apply to laboratory methods for testing and examination?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to laboratory methods for testing and examination? 111.320 Section 111.320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING...

  15. Multidisciplinary eHealth Survey Evaluation Methods

    Science.gov (United States)

    Karras, Bryant T.; Tufano, James T.

    2006-01-01

    This paper describes the development process of an evaluation framework for describing and comparing web survey tools. We believe that this approach will help shape the design, development, deployment, and evaluation of population-based health interventions. A conceptual framework for describing and evaluating web survey systems will enable the…

  16. Evaluation of quality assurance/quality control data collected by the U.S. Geological Survey for water-quality activities at the Idaho National Engineering and Environmental Laboratory, Idaho, 1994 through 1995

    International Nuclear Information System (INIS)

    Williams, L.M.

    1997-03-01

    More than 4,000 water samples were collected by the US Geological Survey (USGS) from 179 monitoring sites for the water-quality monitoring program at the Idaho National Engineering Laboratory from 1994 through 1995. Approximately 500 of the water samples were replicate or blank samples collected for the quality assurance/quality control program. Analyses were performed to determine the concentrations of major ions, nutrients, trace elements, gross radioactivity and radionuclides, total organic carbon, and volatile organic compounds in the samples. To evaluate the precision of field and laboratory methods, analytical results of the replicate pairs of samples were compared statistically for equivalence on the basis of the precision associated with each result. In all, the statistical comparison of the data indicated that 95% of the replicate pairs were equivalent. Within the major ion analyses, 97% were equivalent; nutrients, 88%; trace elements, 95%; gross radioactivity and radionuclides, 93%; and organic constituents, 98%. Ninety percent or more of the analytical results for each constituent were equivalent, except for nitrite, orthophosphate, phosphorus, aluminum, iron, strontium-90, and total organic carbon

  17. Laboratory Safety Awareness Among General Physics Undergraduate Students

    Directory of Open Access Journals (Sweden)

    C. O. Ponferrada

    2017-12-01

    Full Text Available Safety awareness in the laboratory is essential to reduce occupational risks. This study was conducted to determine the students’ safety awareness in a Physics laboratory. This study determined the student perception towards safety awareness by factors of gender and college from which students are enrolled. A sum of 324 students enrolled in Physics10 (Mechanics and Heat and Physics11 (Electricity and Magnetism in the Mindanao University of Science and Technology (MUST were randomly selected as survey respondents. A modified survey questionnaire was used as research instrument. The results show that the students had positive level of safety awareness and perceived positively on the preventive measures to reduce laboratory risk. Further, regardless of gender students enrolled in Physics 10 were more positively aware towards safety awareness than students enrolled in Physics 11. Similarly, a variation among the students perception towards safety awareness from the College of Engineering and Architecture (CEA and College of Industrial and Information Technology (CIIT occurred. Overall, present findings indicate a need to introduce laboratory safety awareness in Physics classes.

  18. THE PROCEDURE OF REALIZATION OF THE DIDACTIC PRINCIPLE OF VISUAL METHOD IN AN EDUCATIONAL LABORATORY

    Directory of Open Access Journals (Sweden)

    Anatolii H. Protasov

    2010-08-01

    Full Text Available This paper is devoted to the procedure of realization of the main didactic principle – use visual method which becomes an essential factor of student perception of educational sources. The procedure is realized with series of laboratory works which are based on the principle – “device-computer-software”. The transformers of a physical magnitude into electrical signal are used in laboratory works. The combination of these transformers and a computer form the device which can measure a physical magnitude. The software allows reconstructing a virtual field distribution of this magnitude in area and observing its history. MATLAB is used as software and it provides with computation of different physical processes. The proposed procedure provides with a direct visual method and an indirect one as well. This matter promotes forming future specialists’ professional competence.

  19. Inter-laboratory comparisons of hexenuronic acid measurements in kraft eucalyptus pulps using a UV-Vis spectroscopic method

    Science.gov (United States)

    J.Y. Zhu; H.F Zhou; Chai X.S.; Donna Johannes; Richard Pope; Cristina Valls; M. Blanca Roncero

    2014-01-01

    An inter-laboratory comparison of a UV-Vis spectroscopic method (TAPPI T 282 om-13 “Hexeneuronic acid content of chemical pulp”) for hexeneuronic acid measurements was conducted using three eucalyptus kraft pulps. The pulp samples were produced in a laboratory at kappa numbers of approximately 14, 20, and 35. The hexeneuronic acid contents of the three pulps were...

  20. Materials characterization capabilities at DOE Nuclear Weapons Laboratories and Production Plants

    International Nuclear Information System (INIS)

    Pyper, J.W.

    1984-06-01

    The materials characterization and analytical chemistry capabilities at the 11 DOE Nuclear Weapons Laboratories or Production Plants have been surveyed and compared. In general, all laboratories have similar capabilities and equipment. Facilities or capabilities that are unique or that exist at only a few laboratories are described in detail

  1. Availability of urinary albumin measurement in Southern Brazilian laboratories

    Directory of Open Access Journals (Sweden)

    Ariana Aguiar Soares

    2015-03-01

    Full Text Available Introduction: Diabetic kidney disease (DKD is the leading worldwide cause of end-stage renal disease. The current recommendation is to screen for DKD by evaluating estimated glomerular filtration rate (eGFR and measuring urinary albumin (UA levels in a spot sample. The aim of this study was to evaluate the availability of UA measurement in Southern Brazilian laboratories.   Methods: A cross-sectional study was conducted to assess the routine use of UA in all laboratories registered in the State Pharmacy Council ofRio Grande do Sul, the southernmost state ofBrazil. Data was collected by mail, e-mail, telephone, or personal interview. A sample size of at least 384 laboratories was necessary to achieve 5% precision at a 95% confidence level based on a fixed proportion of 0.5.   Results: Eight hundred and eighty laboratories currently registered in the state were invited to participate in the study; 548 (62% answered the technical specification questionnaire. Only 306 (55% of the 548 surveyed laboratories performed UA measurements. The laboratories were also required to provide the number of UA measurements performed per day, which ranged from less than one per week to 65 per day.  Conclusion: The availability of UA measurements is undesirably low inSouthern Brazil. This demonstrates the urgent need to increase the availability of this important test. It also reveals the gap between the current guidelines and the awareness about them among health care professionals.

  2. [Comparison study on sampling methods of Oncomelania hupensis snail survey in marshland schistosomiasis epidemic areas in China].

    Science.gov (United States)

    An, Zhao; Wen-Xin, Zhang; Zhong, Yao; Yu-Kuan, Ma; Qing, Liu; Hou-Lang, Duan; Yi-di, Shang

    2016-06-29

    To optimize and simplify the survey method of Oncomelania hupensis snail in marshland endemic region of schistosomiasis and increase the precision, efficiency and economy of the snail survey. A quadrate experimental field was selected as the subject of 50 m×50 m size in Chayegang marshland near Henghu farm in the Poyang Lake region and a whole-covered method was adopted to survey the snails. The simple random sampling, systematic sampling and stratified random sampling methods were applied to calculate the minimum sample size, relative sampling error and absolute sampling error. The minimum sample sizes of the simple random sampling, systematic sampling and stratified random sampling methods were 300, 300 and 225, respectively. The relative sampling errors of three methods were all less than 15%. The absolute sampling errors were 0.221 7, 0.302 4 and 0.047 8, respectively. The spatial stratified sampling with altitude as the stratum variable is an efficient approach of lower cost and higher precision for the snail survey.

  3. Determination of Calcium in Dietary Supplements: Statistical Comparison of Methods in the Analytical Laboratory

    Science.gov (United States)

    Garvey, Sarah L.; Shahmohammadi, Golbon; McLain, Derek R.; Dietz, Mark L.

    2015-01-01

    A laboratory experiment is described in which students compare two methods for the determination of the calcium content of commercial dietary supplement tablets. In a two-week sequence, the sample tablets are first analyzed via complexometric titration with ethylenediaminetetraacetic acid and then, following ion exchange of the calcium ion present…

  4. Comparison of Laboratory and Field Remote Sensing Methods to Measure Forage Quality

    OpenAIRE

    Guo, Xulin; Wilmshurst, John F.; Li, Zhaoqin

    2010-01-01

    Recent research in range ecology has emphasized the importance of forage quality as a key indicator of rangeland condition. However, we lack tools to evaluate forage quality at scales appropriate for management. Using canopy reflectance data to measure forage quality has been conducted at both laboratory and field levels separately, but little work has been conducted to evaluate these methods simultaneously. The objective of this study is to find a reliable way of assessing grassland quality ...

  5. Monitoring laboratory data across manufacturers and laboratories--A prerequisite to make "Big Data" work.

    Science.gov (United States)

    Goossens, Kenneth; Van Uytfanghe, Katleen; Twomey, Patrick J; Thienpont, Linda M

    2015-05-20

    "The Percentiler" project provides quasi real-time access to patient medians across laboratories and manufacturers. This data can serve as "clearinghouse" for electronic health record applications, e.g., use of laboratory data for global health-care research. Participants send their daily outpatient medians to the Percentiler application. After 6 to 8weeks, the laboratory receives its login information, which gives access to the user interface. Data is assessed by peer group, i.e., 10 or more laboratories using the same test system. Participation is free of charge. Participation is global with, to date, >120 laboratories and >250 instruments. Up to now, several reports have been produced that address i) the general features of the project, ii) peer group observations; iii) synergisms between "The Percentiler" and dedicated external quality assessment surveys. Reasons for long-term instability and bias (calibration- or lot-effects) have been observed for the individual laboratory and manufacturers. "The Percentiler" project has the potential to build a continuous, global evidence base on in vitro diagnostic test comparability and stability. As such, it may be beneficial for all stakeholders and, in particular, the patient. The medical laboratory is empowered for contributing to the development, implementation, and management of global health-care policies. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Geophysical survey work plan for White Wing Scrap Yard (Waste Area Grouping 11) at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1994-02-01

    The White Wing Scrap Yard, located on the U.S. Department of Energy's Oak Ridge Reservation, served as an aboveground storage and disposal area for contaminated debris and scrap from the Oak Ridge K-25 Site, the Oak Ridge Y-12 Plant, and the Oak Ridge National laboratory. The site is believed to have been active from the early 1950s until the mid-1960s. A variety of materials were disposed of at the site, including contaminated steel tanks and vehicles. As an interim corrective action, a surface debris removal effort was initiated in November 1993 to reduce the potential threat to human health and the environment from the radionuclide-contaminated debris. Following this removal effort, a geophysical survey will be conducted across the site to locate and determine the lateral extent of buried nonindigenous materials. This survey will provide the data necessary to prepare a map showing areas of conductivity and magnetic intensity that vary from measured background values. These anomalies represent potential buried materials and therefore can be targeted for further evaluation. This work plan outlines the activities necessary to conduct the geophysical survey

  7. U.S. Geological Survey experience with the residual absolutes method

    Directory of Open Access Journals (Sweden)

    E. W. Worthington

    2017-10-01

    Full Text Available The U.S. Geological Survey (USGS Geomagnetism Program has developed and tested the residual method of absolutes, with the assistance of the Danish Technical University's (DTU Geomagnetism Program. Three years of testing were performed at College Magnetic Observatory (CMO, Fairbanks, Alaska, to compare the residual method with the null method. Results show that the two methods compare very well with each other and both sets of baseline data were used to process the 2015 definitive data. The residual method will be implemented at the other USGS high-latitude geomagnetic observatories in the summer of 2017 and 2018.

  8. National Survey on Access, Use and Promotion of Rational Use of Medicines (PNAUM: household survey component methods

    Directory of Open Access Journals (Sweden)

    Sotero Serrate Mengue

    Full Text Available ABSTRACT OBJECTIVE To describe methodological aspects of the household survey National Survey on Access, Use and Promotion of Rational Use of Medicines (PNAUM related to sampling design and implementation, the actual obtained sample, instruments and fieldwork. METHODS A cross-sectional, population-based study with probability sampling in three stages of the population living in households located in Brazilian urban areas. Fieldwork was carried out between September 2013 and February 2014. The data collection instrument included questions related to: information about households, residents and respondents; chronic diseases and medicines used; use of health services; acute diseases and events treated with drugs; use of contraceptives; use of pharmacy services; behaviors that may affect drug use; package inserts and packaging; lifestyle and health insurance. RESULTS In total, 41,433 interviews were carried out in 20,404 households and 576 urban clusters corresponding to 586 census tracts distributed in the five Brazilian regions, according to eight domains defined by age and gender. CONCLUSIONS The results of the survey may be used as a baseline for future studies aiming to assess the impact of government action on drug access and use. For local studies using a compatible method, PNAUM may serve as a reference point to evaluate variations in space and population. With a comprehensive evaluation of drug-related aspects, PNAUM is a major source of data for a variety of analyses to be carried out both at academic and government level.

  9. Methods for rapidly processing angular masks of next-generation galaxy surveys

    Science.gov (United States)

    Swanson, M. E. C.; Tegmark, Max; Hamilton, Andrew J. S.; Hill, J. Colin

    2008-07-01

    As galaxy surveys become larger and more complex, keeping track of the completeness, magnitude limit and other survey parameters as a function of direction on the sky becomes an increasingly challenging computational task. For example, typical angular masks of the Sloan Digital Sky Survey contain about N = 300000 distinct spherical polygons. Managing masks with such large numbers of polygons becomes intractably slow, particularly for tasks that run in time with a naive algorithm, such as finding which polygons overlap each other. Here we present a `divide-and-conquer' solution to this challenge: we first split the angular mask into pre-defined regions called `pixels', such that each polygon is in only one pixel, and then perform further computations, such as checking for overlap, on the polygons within each pixel separately. This reduces tasks to , and also reduces the important task of determining in which polygon(s) a point on the sky lies from to , resulting in significant computational speedup. Additionally, we present a method to efficiently convert any angular mask to and from the popular HEALPIX format. This method can be generically applied to convert to and from any desired spherical pixelization. We have implemented these techniques in a new version of the MANGLE software package, which is freely available at http://space.mit.edu/home/tegmark/mangle/, along with complete documentation and example applications. These new methods should prove quite useful to the astronomical community, and since MANGLE is a generic tool for managing angular masks on a sphere, it has the potential to benefit terrestrial mapmaking applications as well.

  10. Corrosion Screening of EV31A Magnesium and Other Magnesium Alloys using Laboratory-Based Accelerated Corrosion and Electro-Chemical Methods

    Science.gov (United States)

    2014-07-01

    Spray. Journal of Failure Analysis and Prevention 2008, 8 (2), 164–175. 34. Aluminium Alloy 5083, Plate and Sheet; SAE-AMS-QQ-A-250/6S; SAE...Corrosion Screening of EV31A Magnesium and Other Magnesium Alloys Using Laboratory-Based Accelerated Corrosion and Electro-chemical Methods...Magnesium and Other Magnesium Alloys Using Laboratory-Based Accelerated Corrosion and Electro-chemical Methods Brian E. Placzankis, Joseph P

  11. Survey of systems safety analysis methods and their application to nuclear waste management systems

    International Nuclear Information System (INIS)

    Pelto, P.J.; Winegardner, W.K.; Gallucci, R.H.V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study

  12. Survey of systems safety analysis methods and their application to nuclear waste management systems

    Energy Technology Data Exchange (ETDEWEB)

    Pelto, P.J.; Winegardner, W.K.; Gallucci, R.H.V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study.

  13. NREL Partnership Survey - FY 2016 Results

    Energy Technology Data Exchange (ETDEWEB)

    2016-09-01

    The National Renewable Energy Laboratory (NREL) conducts an annual partnership satisfaction survey in which we ask our clients to rate NREL in a number of areas. As a national laboratory, the principal areas we focus on include value, timeliness, quality, price, and capabilities. This fact sheet shows the results of a survey with 300 customers responding to 11 questions using ratings that vary from 'strongly agree' to 'strongly disagree.' In FY 16, 100% of the scores improved or were equal to FY 15 numbers.

  14. Sample Size Calculations for Population Size Estimation Studies Using Multiplier Methods With Respondent-Driven Sampling Surveys.

    Science.gov (United States)

    Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R

    2017-09-14

    While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.

  15. Laboratory quality assurance

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1977-01-01

    The elements (principles) of quality assurance can be applied to the operation of the analytical chemistry laboratory to provide an effective tool for indicating the competence of the laboratory and for helping to upgrade competence if necessary. When used, those elements establish the planned and systematic actions necessary to provide adequate confidence in each analytical result reported by the laboratory (the definition of laboratory quality assurance). The elements, as used at the Hanford Engineering Development Laboratory (HEDL), are discussed and they are qualification of analysts, written methods, sample receiving and storage, quality control, audit, and documentation. To establish a laboratory quality assurance program, a laboratory QA program plan is prepared to specify how the elements are to be implemented into laboratory operation. Benefits that can be obtained from using laboratory quality assurance are given. Experience at HEDL has shown that laboratory quality assurance is not a burden, but it is a useful and valuable tool for the analytical chemistry laboratory

  16. [Method of immunocytochemical demonstration of cholinergic neurons in the central nervous system of laboratory animals].

    Science.gov (United States)

    Korzhevskiĭ, D E; Grigor'ev, I P; Kirik, O V; Zelenkova, N M; Sukhorukova, E G

    2013-01-01

    A protocol of immunocytochemical demonstration of choline acetyltransferase (ChAT), a key enzyme of acetylcholine synthesis, in paraffin sections of the brain of some laboratory animals, is presented. The method is simple, gives fairly reproducible results and allows for demonstration of ChAT in neurons, nerve fibers, and terminals in preparations of at least three species of laboratory animals including rat, rabbit, and cat. Different kinds of fixation (10% formalin, 4% paraformaldehyde, or zinc-ethanol-formaldehyde) were found suitable for immunocytochemical visualization of ChAT, however, optimal results were obtained with the application of zinc-ethanol-formaldehyde

  17. A Survey of Symplectic and Collocation Integration Methods for Orbit Propagation

    Science.gov (United States)

    Jones, Brandon A.; Anderson, Rodney L.

    2012-01-01

    Demands on numerical integration algorithms for astrodynamics applications continue to increase. Common methods, like explicit Runge-Kutta, meet the orbit propagation needs of most scenarios, but more specialized scenarios require new techniques to meet both computational efficiency and accuracy needs. This paper provides an extensive survey on the application of symplectic and collocation methods to astrodynamics. Both of these methods benefit from relatively recent theoretical developments, which improve their applicability to artificial satellite orbit propagation. This paper also details their implementation, with several tests demonstrating their advantages and disadvantages.

  18. Metal speciation: survey of environmental methods of analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mach, M.H.; Nott, B.; Scott, J.W.; Maddalone, R.F.; Whiddon, N.T. [TRW, Redondo Beach, CA (United States). Chemistry Technology Dept.

    1996-07-01

    As part of a recent task under the EPRI Analytical Methods Qualification Program (RP 1851), TRW has surveyed the methods available for monitoring metal species in typical utility aqueous discharge streams. Methods for determining the individual species of these metals can become important in a regulatory sense as the EPA transitions to assessment of environmental risk based on bioavailability. For example, EPA considers methyl mercury and Cr(VI) much more toxic to the aquatic environment than inorganic mercury or Cr(III). The species of a given element can also differ in their transport and bioaccumulation. Methods for speciation generally include a selective separation step followed by standard metals analysis. Speciation, therefore, is mainly derived from the separation step and not from the method of final quantisation. Examples of separation/analysis include: selective extraction followed by graphite furnace atomic absorption or ICP-MS; separation by GC followed by metals detection; chelation and/or direct separation by LC followed by UV measurement or metals detection; and ion chromatography with conductivity, UV, or metals detection. There are a number of sampling issues associated with metal species such as stabilization (maintaining oxidation state), absorption, and filtration that need to be addressed in order to obtain and maintain a representative sample for analysis. 45 refs., 1 tab.

  19. Survey on morphometric characteristic of different developmental stages of Dermacentor marginatus under laboratory conditions

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Darvishi

    2014-09-01

    Full Text Available Objective: To study the morphometric characteristics and biology of different developmental stages of Dermacentor marginatus (D. marginatus under laboratory conditions. Methods: D. marginatus ticks were collected from sheep in Shahmirzad and suburb. The identification of D. marginatus was carried out by means of stereoscope and light microscope according to available systematic keys. Nourished female ticks weight and their length of body, capitulum and mouth parts were measured. After laying eggs and breeding, the weight of all developmental larva stages and the length of mouth parts were measured and recorded carefully. Results: The mean of egg dimension was 566 µm伊436 µm. The length of unfed larva body, hypostome and capitulum were (690依10 µm, (75依5 µm and (172依7 µm, respectively. The weight of egg was calculated 0.05 mg and the weight of unfed larva, nymph and female were 0.02 mg, 0.14 mg and 4.66 mg, respectively; whereas the weight of replete larva, nymph and female were recorded 0.5 mg, 11 mg and 380 mg, respectively. Moreover, the length of unfed nymph, hypostome and capitulum were recorded (1300依50 µm, (135依5 µm and (280依10 µm, respectively. The longest length and width in replete female were observed to be 12.6 mm伊8.4 mm. Conclusions: The current investigation presents new information on biology of D. marginatus under standard laboratory conditions. Besides, investigation on ticks under laboratory conditions increases our knowledge regarding their biology and potential risks.

  20. Applicability of initial stress measurement methods to Horonobe Siliceous rocks and initial stress state around Horonobe Underground Research Laboratory

    International Nuclear Information System (INIS)

    Sanada, Hiroyuki; Niunoya, Sumio; Matsui, Hiroya; Fujii, Yoshiaki

    2009-01-01

    Understanding initial stress condition in deep underground is important for such construction as rock cavern for geological disposal of HLW and underground power plant. Neogene sedimentary rock is widely distributed in Japan. There are only a few studies of initial stress measurement in Neogene sedimentary rock mass in Japan due to difficulty of measurement. Evaluation of initial stress condition around Horonobe Underground Research Laboratory Project was carried out in order to understand initial stress condition and applicability of AE, DSCA and hydraulic fracturing (HF) methods to Neogene sedimentary rock. Initial stress values obtained from AE method is smaller than overburden pressure due to time dependency of Kaizer effect. It would be difficult to use AE method as initial stress measurement method for Horonobe Siliceous rocks. Principal stress values by DSCA are similar to those by HF tests. Directions of maximum horizontal principal stresses are approximately in E-W and corresponded to HF results. In HF, rod type and wire-line type systems were compared. Workability of rod type was much better than wire-line type. However, re-opening pressure were not able to be precisely measured in case of rod type system due to the large compliance of the packers and rods. Horizontal maximum and minimum principal stresses increase linearly in HF results. Deviatoric stress is acting at shallow depth. Initial stress condition approaches hydrostatic condition with depth. Direction of maximum horizontal principal stress was in E-W direction which was similar to tectonic movement around Horonobe URL by triangular surveying. (author)

  1. New method for rearing Spodoptera frugiperda in laboratory shows that larval cannibalism is not obligatory

    Directory of Open Access Journals (Sweden)

    Cherre Sade Bezerra Da Silva

    2013-09-01

    Full Text Available New method for rearing Spodoptera frugiperda in laboratory shows that larval cannibalism is not obligatory. Here we show, for the first time, that larvae of the fall armyworm (FAW, Spodoptera frugiperda (Lepidoptera, Noctuidae, can be successfully reared in a cohort-based manner with virtually no cannibalism. FAW larvae were reared since the second instar to pupation in rectangular plastic containers containing 40 individuals with a surprisingly ca. 90% larval survivorship. Adult females from the cohort-based method showed fecundity similar to that already reported on literature for larvae reared individually, and fertility higher than 99%, with the advantage of combining economy of time, space and material resources. These findings suggest that the factors affecting cannibalism of FAW larvae in laboratory rearings need to be reevaluated, whilst the new technique also show potential to increase the efficiency of both small and mass FAW rearings.

  2. Noise study in laboratories with exhaust fans

    International Nuclear Information System (INIS)

    Shaikh, G.H.; Hashmi, R.; Shareef, A.

    2005-01-01

    Noise study has been carried out in 25 laboratories fitted with exhaust fans. We have studied A- Weighted equivalent sound pressure levels (dB(A) LAeJ and equivalent octave band sound pressure levels (dB L/sub eq/ in each of the laboratories surveyed. The data collected has been analyzed for Preferred Speech Interference Levels (PSIL). The results show that the interior noise levels in these laboratories vary from 59.6 to 72.2 dB(A) L/sub Aeq/, which are very high and much beyond the interior noise limits recommended for laboratories. Some ways and means to limit emission of high-level noise from exhaust fans are also discussed. (author)

  3. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  4. Laboratory analytical methods for the determination of the hydrocarbon status of soils (a review)

    Science.gov (United States)

    Pikovskii, Yu. I.; Korotkov, L. A.; Smirnova, M. A.; Kovach, R. G.

    2017-10-01

    Laboratory analytical methods suitable for the determination of the hydrocarbon status of soils (a specific soil characteristic involving information on the total content and qualitative features of soluble (bitumoid) carbonaceous substances and individual hydrocarbons (polycyclic aromatic hydrocarbons, alkanes, etc.) in bitumoid, as well as the composition and content of hydrocarbon gases) have been considered. Among different physicochemical methods of study, attention is focused on the methods suitable for the wide use. Luminescence-bituminological analysis, low-temperature spectrofluorimetry (Shpolskii spectroscopy), infrared (IR) spectroscopy, gas chromatography, chromatography-mass spectrometry, and some other methods have been characterized, as well as sample preparation features. Advantages and limitations of each of these methods are described; their efficiency, instrumental complexity, analysis duration, and accuracy are assessed.

  5. Examining Stress in Graduate Assistants: Combining Qualitative and Quantitative Survey Methods

    Science.gov (United States)

    Mazzola, Joseph J.; Walker, Erin J.; Shockley, Kristen M.; Spector, Paul E.

    2011-01-01

    The aim of this study was to employ qualitative and quantitative survey methods in a concurrent mixed model design to assess stressors and strains in graduate assistants. The stressors most frequently reported qualitatively were work overload, interpersonal conflict, and organizational constraints; the most frequently reported psychological…

  6. Studying Landslide Displacements in Megamendung (Indonesia Using GPS Survey Method

    Directory of Open Access Journals (Sweden)

    Hasanuddin Z. Abidin

    2004-11-01

    Full Text Available Landslide is one of prominent geohazards that frequently affects Indonesia, especially in the rainy season. It destroys not only environment and property, but usually also causes deaths. Landslide monitoring is therefore very crucial and should be continuously done. One of the methods that can have a contribution in studying landslide phenomena is repeated GPS survey method. This paper presents and discusses the operational performances, constraints and results of GPS surveys conducted in a well known landslide prone area in West Java (Indonesia, namely Megamendung, the hilly region close to Bogor. Three GPS surveys involving 8 GPS points have been conducted, namely on April 2002, May 2003 and May 2004, respectively. The estimated landslide displacements in the area are relatively quite large in the level of a few dm to a few m. Displacements up to about 2-3 m were detected in the April 2002 to May 2003 period, and up to about 3-4 dm in the May 2003 to May 2004 period. In both periods, landslides in general show the northwest direction of displacements. Displacements vary both spatially and temporally. This study also suggested that in order to conclude the existence of real and significant displacements of GPS points, the GPS estimated displacements should be subjected to three types of testing namely: the congruency test on spatial displacements, testing on the agreement between the horizontal distance changes with the predicted direction of landslide displacement, and testing on the consistency of displacement directions on two consecutive periods.

  7. Assessment of readiness for clinical decision support to aid laboratory monitoring of immunosuppressive care at U.S. liver transplant centers.

    Science.gov (United States)

    Jacobs, J; Weir, C; Evans, R S; Staes, C

    2014-01-01

    Following liver transplantation, patients require lifelong immunosuppressive care and monitoring. Computerized clinical decision support (CDS) has been shown to improve post-transplant immunosuppressive care processes and outcomes. The readiness of transplant information systems to implement computerized CDS to support post-transplant care is unknown. a) Describe the current clinical information system functionality and manual and automated processes for laboratory monitoring of immunosuppressive care, b) describe the use of guidelines that may be used to produce computable logic and the use of computerized alerts to support guideline adherence, and c) explore barriers to implementation of CDS in U.S. liver transplant centers. We developed a web-based survey using cognitive interviewing techniques. We surveyed 119 U.S. transplant programs that performed at least five liver transplantations per year during 2010-2012. Responses were summarized using descriptive analyses; barriers were identified using qualitative methods. Respondents from 80 programs (67% response rate) completed the survey. While 98% of programs reported having an electronic health record (EHR), all programs used paper-based manual processes to receive or track immunosuppressive laboratory results. Most programs (85%) reported that 30% or more of their patients used external laboratories for routine testing. Few programs (19%) received most external laboratory results as discrete data via electronic interfaces while most (80%) manually entered laboratory results into the EHR; less than half (42%) could integrate internal and external laboratory results. Nearly all programs had guidelines regarding pre-specified target ranges (92%) or testing schedules (97%) for managing immunosuppressive care. Few programs used computerized alerting to notify transplant coordinators of out-of-range (27%) or overdue laboratory results (20%). Use of EHRs is common, yet all liver transplant programs were largely

  8. Comparison of survey and photogrammetry methods to position gravity data, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Ponce, D.A.; Wu, S.S.C.; Spielman, J.B.

    1985-01-01

    Locations of gravity stations at Yucca Mountain, Nevada, were determined by a survey using an electronic distance-measuring device and by a photogram-metric method. The data from both methods were compared to determine if horizontal and vertical coordinates developed from photogrammetry are sufficently accurate to position gravity data at the site. The results show that elevations from the photogrammetric data have a mean difference of 0.57 +- 0.70 m when compared with those of the surveyed data. Comparison of the horizontal control shows that the two methods agreed to within 0.01 minute. At a latitude of 45 0 , an error of 0.01 minute (18 m) corresponds to a gravity anomaly error of 0.015 mGal. Bouguer gravity anomalies are most sensitive to errors in elevation, thus elevation is the determining factor for use of photogrammetric or survey methods to position gravity data. Because gravity station positions are difficult to locate on aerial photographs, photogrammetric positions are not always exactly at the gravity station; therefore, large disagreements may appear when comparing electronic and photogrammetric measurements. A mean photogrammetric elevation error of 0.57 m corresponds to a gravity anomaly error of 0.11 mGal. Errors of 0.11 mGal are too large for high-precision or detailed gravity measurements but acceptable for regional work. 1 ref. 2 figs., 4 tabs

  9. Formal methods for industrial critical systems a survey of applications

    CERN Document Server

    Margaria-Steffen, Tiziana

    2012-01-01

    "Today, formal methods are widely recognized as an essential step in the design process of industrial safety-critical systems. In its more general definition, the term formal methods encompasses all notations having a precise mathematical semantics, together with their associated analysis methods, that allow description and reasoning about the behavior of a system in a formal manner.Growing out of more than a decade of award-winning collaborative work within the European Research Consortium for Informatics and Mathematics, Formal Methods for Industrial Critical Systems: A Survey of Applications presents a number of mainstream formal methods currently used for designing industrial critical systems, with a focus on model checking. The purpose of the book is threefold: to reduce the effort required to learn formal methods, which has been a major drawback for their industrial dissemination; to help designers to adopt the formal methods which are most appropriate for their systems; and to offer a panel of state-of...

  10. Survey on the practice of lingual orthodontics in India

    Directory of Open Access Journals (Sweden)

    Sourabh Agrawal

    2016-01-01

    Full Text Available Aim: Lingual orthodontics provides an esthetic option of orthodontic treatment, especially for the adults. Lingual orthodontics being an important treatment modality requires extensive training and expertise for honest outcomes. In this study, we have composed a questionnaire to obtain the trend in the practice of lingual orthodontics in India. Materials and Methods: A questionnaire was composed of several aspects of lingual orthodontics. The survey instrument was hosted electronically on a secure website, www.typeform.com . The survey was optimized for presentation on tablets, mobiles, and laptops, which were the platforms used by participants to take the survey. The survey data were received and saved by the same secure website. Pearson Chi-square test was done using SPSS 17.0 version software to determine the correlation between treatment outcome and the use of laboratory for the initial setup. Results: A total of 248 orthodontists responded to the survey, 70% orthodontists said that they practice lingual orthodontics. Among the orthodontists who practice lingual orthodontics, 71% orthodontists treat extraction and nonextraction cases and 29% treat only nonextraction cases. Forty percent orthodontists said their final finishing of case is good, 16% said that final finishing is average, 26.5% said that final finishing is very good, and only 17.5% said that it is excellent. Statistically significant correlation exists (P = 0.004 between the treatment outcome and use of laboratory for initial setup. Conclusion: Many orthodontists are taking up lingual cases in India. Survey indicates that there is still room for betterment in terms of the final treatment outcome, and many orthodontists feel that there is need of formal training for expertise in lingual orthodontics.

  11. Field and laboratory arsenic speciation methods and their application to natural-water analysis

    Science.gov (United States)

    Bednar, A.J.; Garbarino, J.R.; Burkhardt, M.R.; Ranville, J.F.; Wildeman, T.R.

    2004-01-01

    The toxic and carcinogenic properties of inorganic and organic arsenic species make their determination in natural water vitally important. Determination of individual inorganic and organic arsenic species is critical because the toxicology, mobility, and adsorptivity vary substantially. Several methods for the speciation of arsenic in groundwater, surface-water, and acid mine drainage sample matrices using field and laboratory techniques are presented. The methods provide quantitative determination of arsenite [As(III)], arsenate [As(V)], monomethylarsonate (MMA), dimethylarsinate (DMA), and roxarsone in 2-8min at detection limits of less than 1??g arsenic per liter (??g AsL-1). All the methods use anion exchange chromatography to separate the arsenic species and inductively coupled plasma-mass spectrometry as an arsenic-specific detector. Different methods were needed because some sample matrices did not have all arsenic species present or were incompatible with particular high-performance liquid chromatography (HPLC) mobile phases. The bias and variability of the methods were evaluated using total arsenic, As(III), As(V), DMA, and MMA results from more than 100 surface-water, groundwater, and acid mine drainage samples, and reference materials. Concentrations in test samples were as much as 13,000??g AsL-1 for As(III) and 3700??g AsL-1 for As(V). Methylated arsenic species were less than 100??g AsL-1 and were found only in certain surface-water samples, and roxarsone was not detected in any of the water samples tested. The distribution of inorganic arsenic species in the test samples ranged from 0% to 90% As(III). Laboratory-speciation method variability for As(III), As(V), MMA, and DMA in reagent water at 0.5??g AsL-1 was 8-13% (n=7). Field-speciation method variability for As(III) and As(V) at 1??g AsL-1 in reagent water was 3-4% (n=3). ?? 2003 Elsevier Ltd. All rights reserved.

  12. Exploring a Laboratory Model of Pharmacogenetics as Applied to Clinical Decision Making

    Directory of Open Access Journals (Sweden)

    Angela Smith, PharmD Candidate

    2013-01-01

    Full Text Available Objective: To evaluate a pilot of a laboratory model for relating pharmacogenetics to clinical decision making. Case Study: This pilot was undertaken and evaluated to help determine if a pharmacogenetics laboratory should be included in the core Doctor of Pharmacy curriculum. The placement of the laboratory exercise in the curriculum was determined by identifying the point in the curriculum where the students had been introduced to the chemistry of deoxyribonucleic acid (DNA as well as instructed on the chemistry of genetic variation. The laboratory included cytochrome P450 2C19 genotyping relative to the *2 variant. Twenty-four students served as the pilot group. Students provided buccal swabs as the source of DNA. Students stabilized the samples and were then provided instructions related to sample preparation, polymerase chain reaction, and gel electrophoresis. The results were reported as images of gels. Students used a reference gel image to compare their results to. Students then applied a dosing algorithm to make a “clinical decision” relative to clopidogrel use. Students were offered a post laboratory survey regarding attitudes toward the laboratory. Twenty-four students completed the laboratory with genotyping results being provided for 22 students (91.7%. Sixteen students were wild-type (*1/*1, while six students were heterozygous (*1/*2. Twenty-three students (96% completed the post laboratory survey. All 23 agreed (6, 26.1% or strongly agreed (17, 73.9% that the laboratory “had relevance and value in the pharmacy curriculum”. Conclusion: The post pilot study survey exploring a laboratory model for pharmacogenetics related to clinical decision making indicated that such a laboratory would be viewed positively by students. This model may be adopted by colleges to expand pharmacogenetics education.

  13. Exploring a Laboratory Model of Pharmacogenetics as Applied to Clinical Decision Making

    Directory of Open Access Journals (Sweden)

    David F. Kisor

    2013-01-01

    Full Text Available Objective: To evaluate a pilot of a laboratory model for relating pharmacogenetics to clinical decision making. Case Study: This pilot was undertaken and evaluated to help determine if a pharmacogenetics laboratory should be included in the core Doctor of Pharmacy curriculum. The placement of the laboratory exercise in the curriculum was determined by identifying the point in the curriculum where the students had been introduced to the chemistry of deoxyribonucleic acid (DNA as well as instructed on the chemistry of genetic variation. The laboratory included cytochrome P450 2C19 genotyping relative to the *2 variant. Twenty-four students served as the pilot group. Students provided buccal swabs as the source of DNA. Students stabilized the samples and were then provided instructions related to sample preparation, polymerase chain reaction, and gel electrophoresis. The results were reported as images of gels. Students used a reference gel image to compare their results to. Students then applied a dosing algorithm to make a "clinical decision" relative to clopidogrel use. Students were offered a post laboratory survey regarding attitudes toward the laboratory. Twenty-four students completed the laboratory with genotyping results being provided for 22 students (91.7%. Sixteen students were wild-type (*1/*1, while six students were heterozygous (*1/*2. Twenty-three students (96% completed the post laboratory survey. All 23 agreed (6, 26.1% or strongly agreed (17, 73.9% that the laboratory "had relevance and value in the pharmacy curriculum" Conclusion: The post pilot study survey exploring a laboratory model for pharmacogenetics related to clinical decision making indicated that such a laboratory would be viewed positively by students. This model may be adopted by colleges to expand pharmacogenetics education.   Type: Case Study

  14. Optimum survey methods when interviewing employed women.

    Science.gov (United States)

    Dunning, Kari; LeMasters, Grace K

    2009-02-01

    While survey studies have examined bias much is unknown regarding specific subpopulations, especially women workers. A population based phone, Internet, and mail survey of workplace falls during pregnancy was undertaken. Participation by industry and occupation and survey approach and bias, reliability, and incomplete data were examined. Of the 3,997 women surveyed, 71% were employed during their pregnancy. Internet responders were most likely to be employed while pregnant and to report a workplace fall at 8.8% compared to 5.8% and 6.1% for mail and phone respondents. Internet responders had the most missing employment data with company name missing for 17.9% compared to 1.3% for phone responders. Mail surveys were best for recruiting those employed in eight of nine industries, and this was especially true for service occupations. To decrease bias and increase participation, mixed approaches may be useful with particular attention for collecting occupational data. Am. J. Ind. Med. 52:105-112, 2009. (c) 2008 Wiley-Liss, Inc.

  15. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

    Science.gov (United States)

    Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W

    1995-01-01

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.

  16. Research and Development Project Selection Methods at the Air Force Wright Aeronautical Laboratories.

    Science.gov (United States)

    1985-09-01

    personal and telephone interviews. Ten individuals from each of the four AFWAL Laboratories were interrviewed. The results illustrated that few of the...680). Aaker and Tyebee. 1978. The authors constructed a model that dealt with the selection of interdependent R&D projects. The model covers three...of this research effort. Scope * The data collection method used in this study consisted of a combination of personal and telephone interviews. The

  17. Los Alamos Scientific Laboratory x-ray survey manual

    International Nuclear Information System (INIS)

    Olsher, R.H.

    1980-02-01

    A manual has been developed by the Health Physics Group to establish procedures for routine testing of industrial and analytical x-ray equipment for compliance with applicable LASL administrative requirements and technical bulletins. Radiation protection survey procedures were developed for the following types of equipment: x-ray diffraction and fluorescence analysis systems, industrial cabinet x-ray systems, industrial noncabinet x-ray systems, and electron microscopes

  18. Lupus anticoagulants: first French interlaboratory Etalonorme survey.

    Science.gov (United States)

    Roussi, J; Roisin, J P; Goguel, A

    1996-06-01

    In 1994, the, French National Quality Control Group for Hematology, Etalonorme, conducted a large-scale interlaboratory survey concerning the detection of lupus anticoagulants (LA) involving all the 4,500 French laboratories. Each laboratory received the same batch of a lyophilized citrated plasma (94B3) prepared from a patient with LA that had been confirmed by all the techniques used in the intralaboratory study. In the interlaboratory survey, the screening test was activated partial thromboplastin time (APTT); mean APTT calculated from the results reported by 4,029 labs was prolonged (clotting ratio = 1.44) with a large dispersion (coefficients of variation = 18.8%). APTT of the mixture 94B3 + normal plasma were performed by 2,698 laboratories. No correction of APTT was obtained (R = 1.36, Rosner index = 24) with a wide variation between reagents (17 kaolin. This survey allowed Etalonorme to inform French biologists and draft an educational program for the biologic detection of LA and the identification of its mechanism of action.

  19. Analysis of method of polarization surveying of water surface oil pollution

    Science.gov (United States)

    Zhukov, B. S.

    1979-01-01

    A method of polarization surveying of oil films on the water surface is analyzed. Model calculations of contrasted oil and water obtained with different orientations of the analyzer are discussed. The model depends on the spectral range, water transparency and oil film, and the selection of observational direction.

  20. Benchmarking survey for recycling.

    Energy Technology Data Exchange (ETDEWEB)

    Marley, Margie Charlotte; Mizner, Jack Harry

    2005-06-01

    This report describes the methodology, analysis and conclusions of a comparison survey of recycling programs at ten Department of Energy sites including Sandia National Laboratories/New Mexico (SNL/NM). The goal of the survey was to compare SNL/NM's recycling performance with that of other federal facilities, and to identify activities and programs that could be implemented at SNL/NM to improve recycling performance.

  1. College of American Pathologists Gynecologic Cytopathology Quality Consensus Conference on good laboratory practices in gynecologic cytology: background, rationale, and organization.

    Science.gov (United States)

    Tworek, Joseph A; Henry, Michael R; Blond, Barbara; Jones, Bruce Allen

    2013-02-01

    Gynecologic cytopathology is a heavily regulated field, with Clinical Laboratory Improvement Amendments of 1988 mandating the collection of many quality metrics. There is a lack of consensus regarding methods to collect, monitor, and benchmark these data and how these data should be used in a quality assurance program. Furthermore, the introduction of human papilloma virus testing and proficiency testing has provided more data to monitor. To determine good laboratory practices in quality assurance of gynecologic cytopathology. Data were collected through a written survey consisting of 98 questions submitted to 1245 Clinical Laboratory Improvement Amendments-licensed or Department of Defense laboratories. There were 541 usable responses. Additional input was sought through a Web posting of results and questions on the College of American Pathologists Web site. Four senior authors who authored the survey and 28 cytopathologists and cytotechnologists were assigned to 5 working groups to analyze data and present statements on good laboratory practices in gynecologic cytopathology at the College of American Pathologists Gynecologic Cytopathology Quality Consensus Conference. Ninety-eight attendees at the College of American Pathologists Gynecologic Cytopathology Quality Consensus Conference discussed and voted on good laboratory practice statements to obtain consensus. This paper describes the rationale, background, process, and strengths and limitations of a series of papers that summarize good laboratory practice statements in quality assurance in gynecologic cytopathology.

  2. Alternative method for intramuscular fat analysis using common laboratory equipment.

    Science.gov (United States)

    Segura, J; Calvo, L; Óvilo, C; González-Bulnes, A; Olivares, A; Cambero, M I; López-Bote, C J

    2015-05-01

    A procedure to quantify intramuscular fat was developed using common inexpensive laboratory equipment. Three homogenization methods of lyophilized muscle samples (Ball-mill, Grinder and Mortar) and two extraction methods (Ball-mill or Vortex) were used in turkey meat and pork. Two-hundred mg of lyophilized and homogenized samples were accurately weighed and mixed with 1.5 mL of dichloromethane-methanol (8:2) and shaken either in a Mixer Mill (MM400, Retsch Technology) or in a Vortex. The final mixture was separated by centrifugation. Solvent was evaporated under a nitrogen stream and lipid content was gravimetrically determined. Besides, it was checked that the fatty acid profile was not altered by the protocol used. Moreover, the analysis of 4 replicas from the same sample showed different variation coefficients (16-29%) for the new procedures proposed over a wide range of IMF content. The combination of Grinder and Vortex methodologies can be proposed as a simple and inexpensive alternative to previous ones. Copyright © 2015. Published by Elsevier Ltd.

  3. A simple method for the rapid assessment of the qualitative ESR response of fossil samples to laboratory irradiation

    International Nuclear Information System (INIS)

    Gruen, Rainer

    2006-01-01

    A simple and effective method is proposed for the analysis of the qualitative response of ESR spectra to dosing. The method comprises of the alignment of the spectra, and subtraction of the natural spectrum from those that were subsequently irradiated in the laboratory. In that way, the ESR response to environmental radiation can be compared to the ESR response to laboratory radiation. As illustrated on some tooth enamel and mollusk shell samples, both materials are frequently used in dating and accident dosimetry, the method is very effective for the identification of regions where the two radiation regimes generate qualitatively the same dose response as well as for the isolation of radiation insensitive signals that interfere with those used for dose estimation

  4. Short assessment of the Big Five: robust across survey methods except telephone interviewing.

    Science.gov (United States)

    Lang, Frieder R; John, Dennis; Lüdtke, Oliver; Schupp, Jürgen; Wagner, Gert G

    2011-06-01

    We examined measurement invariance and age-related robustness of a short 15-item Big Five Inventory (BFI-S) of personality dimensions, which is well suited for applications in large-scale multidisciplinary surveys. The BFI-S was assessed in three different interviewing conditions: computer-assisted or paper-assisted face-to-face interviewing, computer-assisted telephone interviewing, and a self-administered questionnaire. Randomized probability samples from a large-scale German panel survey and a related probability telephone study were used in order to test method effects on self-report measures of personality characteristics across early, middle, and late adulthood. Exploratory structural equation modeling was used in order to test for measurement invariance of the five-factor model of personality trait domains across different assessment methods. For the short inventory, findings suggest strong robustness of self-report measures of personality dimensions among young and middle-aged adults. In old age, telephone interviewing was associated with greater distortions in reliable personality assessment. It is concluded that the greater mental workload of telephone interviewing limits the reliability of self-report personality assessment. Face-to-face surveys and self-administrated questionnaire completion are clearly better suited than phone surveys when personality traits in age-heterogeneous samples are assessed.

  5. Current use of equations for estimating glomerular filtration rate in Spanish laboratories.

    Science.gov (United States)

    Gràcia-Garcia, Sílvia; Montañés-Bermúdez, Rosario; Morales-García, Luis J; Díez-de Los Ríos, M José; Jiménez-García, Juan Á; Macías-Blanco, Carlos; Martínez-López, Rosalina; Ruiz-Altarejos, Joaquín; Ruiz-Martín, Guadalupe; Sanz-Hernández, Sonia; Ventura-Pedret, Salvador

    2012-07-17

    In 2006 the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) and the Spanish Society of Nephrology (S.E.N.) developed a consensus document in order to facilitate the diagnosis and monitoring of chronic kidney disease with the incorporation of equations for estimating glomerular filtration rate (eGFR) into laboratory reports. The current national prevalence of eGFR reporting and the degree of adherence to these recommendations among clinical laboratories is unknown. We administered a national survey in 2010-11 to Spanish clinical laboratories. The survey was through e-mail or telephone to laboratories that participated in the SEQC’s Programme for External Quality Assurance, included in the National Hospitals Catalogue 2010, including both primary care and private laboratories. A total of 281 laboratories answered to the survey. Of these, 88.2% reported on the eGFR, with 61.9% reporting on the MDRD equation and 31.6% using the MDRD-IDMS equation. A total of 42.5% of laboratories always reported serum creatinine values, and other variables only when specifically requested. Regarding the way results were presented, 46.2% of laboratories reported the exact numerical value only when the filtration rate was below 60mL/min/1.73m2, while 50.6% reported all values regardless. In 56.3% of the cases reporting eGFR, an interpretive commentary of it was enclosed. Although a high percentage of Spanish laboratories have added eGFR in their reports, this metric is not universally used. Moreover, some aspects, such as the equation used and the correct expression of eGFR results, should be improved.

  6. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  7. Changes in Ultrasonic Velocity from Fluid Substitution, Calculated with Laboratory Methods, Digital Rock Physics, and Biot Theory

    Science.gov (United States)

    Goldfarb, E. J.; Ikeda, K.; Tisato, N.

    2017-12-01

    Seismic and ultrasonic velocities of rocks are function of several variables including fluid saturation and type. Understanding the effect of each variable on elastic waves can be valuable when using seismic methods for subsurface modeling. Fluid type and saturation are of specific interest to volcanology, water, and hydrocarbon exploration. Laboratory testing is often employed to understand the effects of fluids on elastic waves. However, laboratory testing is expensive and time consuming. It normally requires cutting rare samples into regular shapes. Fluid injection can also destroy specimens as removing the fluid after testing can prove difficult. Another option is theoretical modeling, which can be used to predict the effect of fluids on elastic properties, but it is often inaccurate. Alternatively, digital rock physics (DRP) can be used to investigate the effect of fluid substitution. DRP has the benefit of being non invasive, as it does not require regular sample shapes or fluid injection. Here, we compare the three methods for dry and saturated Berea sandstone to test the reliability of DRP. First, ultrasonic velocities were obtained from laboratory testing. Second, for comparison, we used a purely theoretical approach - i.e., Hashin-Shtrikman and Biot theory - to estimate the wave speeds at dry and wet conditions. Third, we used DRP. The dry sample was scanned with micro Computed Tomography (µCT), and a three dimensional (3D) array was recorded. We employed a segmentation-less method to convert each 3D array value to density, porosity, elastic moduli, and wave speeds. Wave propagation was simulated numerically at similar frequency as the laboratory. To simulate fluid substitution, we numerically substituted air values for water and repeated the simulation. The results from DRP yielded similar velocities to the laboratory, and accurately predicted the velocity change from fluid substitution. Theoretical modeling could not accurately predict velocity, and

  8. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  9. Pairing field methods to improve inference in wildlife surveys while accommodating detection covariance.

    Science.gov (United States)

    Clare, John; McKinney, Shawn T; DePue, John E; Loftin, Cynthia S

    2017-10-01

    It is common to use multiple field sampling methods when implementing wildlife surveys to compare method efficacy or cost efficiency, integrate distinct pieces of information provided by separate methods, or evaluate method-specific biases and misclassification error. Existing models that combine information from multiple field methods or sampling devices permit rigorous comparison of method-specific detection parameters, enable estimation of additional parameters such as false-positive detection probability, and improve occurrence or abundance estimates, but with the assumption that the separate sampling methods produce detections independently of one another. This assumption is tenuous if methods are paired or deployed in close proximity simultaneously, a common practice that reduces the additional effort required to implement multiple methods and reduces the risk that differences between method-specific detection parameters are confounded by other environmental factors. We develop occupancy and spatial capture-recapture models that permit covariance between the detections produced by different methods, use simulation to compare estimator performance of the new models to models assuming independence, and provide an empirical application based on American marten (Martes americana) surveys using paired remote cameras, hair catches, and snow tracking. Simulation results indicate existing models that assume that methods independently detect organisms produce biased parameter estimates and substantially understate estimate uncertainty when this assumption is violated, while our reformulated models are robust to either methodological independence or covariance. Empirical results suggested that remote cameras and snow tracking had comparable probability of detecting present martens, but that snow tracking also produced false-positive marten detections that could potentially substantially bias distribution estimates if not corrected for. Remote cameras detected marten

  10. Modern clinical laboratory diagnostics

    International Nuclear Information System (INIS)

    Balakhovskij, I.S.

    1986-01-01

    Laboratory diagnosis is auxillary medical discipline studying specific laboratory symptoms of diseases, revealed by investigations of materials taken from patients. The structure of laboratory servie in our country and abroad, items of laboratory investigations, organizational principles are described. Attention is being given to the cost of analyses, the amount of conducted investigations, methods of result presentation, problems of accuracy, quality control and information content

  11. Methods and representativeness of a European survey in children and adolescents: the KIDSCREEN study

    Directory of Open Access Journals (Sweden)

    von Rueden Ursula

    2007-07-01

    Full Text Available Abstract Background The objective of the present study was to compare three different sampling and questionnaire administration methods used in the international KIDSCREEN study in terms of participation, response rates, and external validity. Methods Children and adolescents aged 8–18 years were surveyed in 13 European countries using either telephone sampling and mail administration, random sampling of school listings followed by classroom or mail administration, or multistage random sampling of communities and households with self-administration of the survey materials at home. Cooperation, completion, and response rates were compared across countries and survey methods. Data on non-respondents was collected in 8 countries. The population fraction (PF, respondents in each sex-age, or educational level category, divided by the population in the same category from Eurostat census data and population fraction ratio (PFR, ratio of PF and their corresponding 95% confidence intervals were used to analyze differences by country between the KIDSCREEN samples and a reference Eurostat population. Results Response rates by country ranged from 18.9% to 91.2%. Response rates were highest in the school-based surveys (69.0%–91.2%. Sample proportions by age and gender were similar to the reference Eurostat population in most countries, although boys and adolescents were slightly underrepresented (PFR Conclusion School-based sampling achieved the highest overall response rates but also produced slightly more biased samples than the other methods. The results suggest that the samples were sufficiently representative to provide reference population values for the KIDSCREEN instrument.

  12. A review of neutron scattering correction for the calibration of neutron survey meters using the shadow cone method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang In; Kim, Bong Hwan; Kim, Jang Lyul; Lee, Jung Il [Health Physics Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a {sup 252}Californium ({sup 252}Cf) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1 - 9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

  13. A review of neutron scattering correction for the calibration of neutron survey meters using the shadow cone method

    International Nuclear Information System (INIS)

    Kim, Sang In; Kim, Bong Hwan; Kim, Jang Lyul; Lee, Jung Il

    2015-01-01

    The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a 252 Californium ( 252 Cf) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1 - 9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered

  14. Transport survey calculations using the spectral collocation method

    International Nuclear Information System (INIS)

    Painter, S.L.; Lyon, J.F.

    1989-01-01

    A novel transport survey code has been developed and is being used to study the sensitivity of stellarator reactor performance to various transport assumptions. Instead of following one of the usual approaches, the steady-state transport equation are solved in integral form using the spectral collocation method. This approach effectively combine the computational efficiency of global models with the general nature of 1-D solutions. A compact torsatron reactor test case was used to study the convergence properties and flexibility of the new method. The heat transport model combined Shaing's model for ripple-induced neoclassical transport, the Chang-Hinton model for axisymmetric neoclassical transport, and neoalcator scaling for anomalous electron heat flux. Alpha particle heating, radiation losses, classical electron-ion heat flow, and external heating were included. For the test problem, the method exhibited some remarkable convergence properties. As the number of basis functions was increased, the maximum, pointwise error in the integrated power balance decayed exponentially until the numerical noise level as reached. Better than 10% accuracy in the globally-averaged quantities was achieved with only 5 basis functions; better than 1% accuracy was achieved with 10 basis functions. The numerical method was also found to be very general. Extreme temperature gradients at the plasma edge which sometimes arise from the neoclassical models and are difficult to resolve with finite-difference methods were easily resolved. 8 refs., 6 figs

  15. Pneumoconiosis and exposures of dental laboratory technicians

    International Nuclear Information System (INIS)

    Rom, W.N.; Lockey, J.E.; Lee, J.S.; Kimball, A.C.; Bang, K.M.; Leaman, H.; Johns, R.E. Jr.; Perrota, D.; Gibbons, H.L.

    1984-01-01

    One hundred and seventy-eight dental laboratory technicians and 69 non-exposed controls participated in an epidemiological respiratory study. Eight technicians who had a mean of 28 years grinding nonprecious metal alloys were diagnosed as having a simple pneumoconiosis by chest radiograph. Mean values for per cent predicted FVC and FEV1 were reduced among male nonsmoker technicians compared to male nonsmoker controls; after controlling for age, there was also a reduction in spirometry with increasing work-years. An industrial hygiene survey was conducted in 13 laboratories randomly selected from 42 laboratories stratified by size and type of operation in the Salt Lake City, Utah metropolitan area. Personal exposures to beryllium and cobalt exceeded the Threshold Limit Values (TLVs) in one laboratory. Occupational exposures in dental laboratories need to be controlled to prevent beryllium-related lung disorders as well as simple pneumoconiosis

  16. Geophysical surveys combined with laboratory soil column experiments to identify and explore risk areas for soil and water pollution in feedlots

    Science.gov (United States)

    Espejo-Pérez, Antonio Jesus; Sainato, Claudia Mabel; Jairo Márquez-Molina, John; Giráldez, Juan Vicente; Vanderlinden, Karl

    2014-05-01

    Changes of land use without a correct planning may produce its deterioration with their social, economical and environmental irreversible consequences over short to medium time range. In Argentina, the expansion of soybean fields induced a reduction of the area of pastures dedicated to stockbreeding. As cattle activity is being progressively concentrated on small pens, at feedlots farms, problems of soil and water pollution, mainly by nitrate, have been detected. The characterization of the spatial and temporal variability of soil water content is very important because the mostly advective transport of solutes. To avoid intensive soil samplings, very expensive, one has to recur to geophysical exploration methods. The objective of this work was to identify risk areas within a feedlot of the NW zone of Buenos Aires Province, in Argentina through geophysical methods. The surveys were carried out with an electromagnetic induction profiler EMI-400 (GSSI) and a Time domain Reflectometry (TDR) survey of depth 0-0.10 m with soil sampling and measurement of moisture content with gravimetric method (0-1.0 m). Several trenches were dug inside the pens and also at a test site, where texture, apparent density, saturated hydraulic conductivity (Ks), electrical conductivity of the saturation paste extract and organic matter content (OM) were measured. The water retention curves for these soils were also determined. At one of the pens undisturbed soil columns were extracted at 3 locations. Laboratory analysis for 0-1.0 m indicated that soil texture was classified as sandy loam, average organic matter content (OM) was greater than 2.3% with low values of apparent density in the first 10 cm. The range of spatial dependence of data suggested that the number of soil samples could be reduced. Soil apparent electrical conductivity (ECa) and soil moisture were well correlated and indicated a clear spatial pattern in the corrals. TDR performance was acceptable to identify the spatial

  17. The method of Sample Management in Neutron Activation Analysis Laboratory-Serpong

    International Nuclear Information System (INIS)

    Elisabeth-Ratnawati

    2005-01-01

    In the testing laboratory used by neutron activation analysis method, sample preparation is the main factor and it can't be neglect. The error in the sample preparation can give result with lower accuracy. In this article is explained the scheme of sample preparation i.e sample receive administration, the separate of sample, fluid and solid sample preparation, sample grouping, irradiation, sample counting and holding the sample post irradiation. If the management of samples were good application based on Standard Operation Procedure, therefore each samples has good traceability. To optimize the management of samples is needed the trained and skilled personal and good facility. (author)

  18. Comparison of Health Examination Survey Methods in Brazil, Chile, Colombia, Mexico, England, Scotland, and the United States.

    Science.gov (United States)

    Mindell, Jennifer S; Moody, Alison; Vecino-Ortiz, Andres I; Alfaro, Tania; Frenz, Patricia; Scholes, Shaun; Gonzalez, Silvia A; Margozzini, Paula; de Oliveira, Cesar; Sanchez Romero, Luz Maria; Alvarado, Andres; Cabrera, Sebastián; Sarmiento, Olga L; Triana, Camilo A; Barquera, Simón

    2017-09-15

    Comparability of population surveys across countries is key to appraising trends in population health. Achieving this requires deep understanding of the methods used in these surveys to examine the extent to which the measurements are comparable. In this study, we obtained detailed protocols of 8 nationally representative surveys from 2007-2013 from Brazil, Chile, Colombia, Mexico, the United Kingdom (England and Scotland), and the United States-countries that that differ in economic and inequity indicators. Data were collected on sampling frame, sample selection procedures, recruitment, data collection methods, content of interview and examination modules, and measurement protocols. We also assessed their adherence to the World Health Organization's "STEPwise Approach to Surveillance" framework for population health surveys. The surveys, which included half a million participants, were highly comparable on sampling methodology, survey questions, and anthropometric measurements. Heterogeneity was found for physical activity questionnaires and biological samples collection. The common age range included by the surveys was adults aged 18-64 years. The methods used in these surveys were similar enough to enable comparative analyses of the data across the 7 countries. This comparability is crucial in assessing and comparing national and subgroup population health, and to assisting the transfer of research and policy knowledge across countries. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Field Application of the Micro Biological Survey Method for a Simple and Effective Assessment of the Microbiological Quality of Water Sources in Developing Countries.

    Science.gov (United States)

    Arienzo, Alyexandra; Sobze, Martin Sanou; Wadoum, Raoul Emeric Guetiya; Losito, Francesca; Colizzi, Vittorio; Antonini, Giovanni

    2015-08-25

    According to the World Health Organization (WHO) guidelines, "safe drinking-water must not represent any significant risk to health over a lifetime of consumption, including different sensitivities that may occur between life stages". Traditional methods of water analysis are usually complex, time consuming and require an appropriately equipped laboratory, specialized personnel and expensive instrumentation. The aim of this work was to apply an alternative method, the Micro Biological Survey (MBS), to analyse for contaminants in drinking water. Preliminary experiments were carried out to demonstrate the linearity and accuracy of the MBS method and to verify the possibility of using the evaluation of total coliforms in 1 mL of water as a sufficient parameter to roughly though accurately determine water microbiological quality. The MBS method was then tested "on field" to assess the microbiological quality of water sources in the city of Douala (Cameroon, Central Africa). Analyses were performed on both dug and drilled wells in different periods of the year. Results confirm that the MBS method appears to be a valid and accurate method to evaluate the microbiological quality of many water sources and it can be of valuable aid in developing countries.

  20. Mobile acoustic transects miss rare bat species: implications of survey method and spatio-temporal sampling for monitoring bats

    Directory of Open Access Journals (Sweden)

    Elizabeth C. Braun de Torrez

    2017-11-01

    Full Text Available Due to increasing threats facing bats, long-term monitoring protocols are needed to inform conservation strategies. Effective monitoring should be easily repeatable while capturing spatio-temporal variation. Mobile acoustic driving transect surveys (‘mobile transects’ have been touted as a robust, cost-effective method to monitor bats; however, it is not clear how well mobile transects represent dynamic bat communities, especially when used as the sole survey approach. To assist biologists who must select a single survey method due to resource limitations, we assessed the effectiveness of three acoustic survey methods at detecting species richness in a vast protected area (Everglades National Park: (1 mobile transects, (2 stationary surveys that were strategically located by sources of open water and (3 stationary surveys that were replicated spatially across the landscape. We found that mobile transects underrepresented bat species richness compared to stationary surveys across all major vegetation communities and in two distinct seasons (dry/cool and wet/warm. Most critically, mobile transects failed to detect three rare bat species, one of which is federally endangered. Spatially replicated stationary surveys did not estimate higher species richness than strategically located stationary surveys, but increased the rate at which species were detected in one vegetation community. The survey strategy that detected maximum species richness and the highest mean nightly species richness with minimal effort was a strategically located stationary detector in each of two major vegetation communities during the wet/warm season.

  1. Mobile acoustic transects miss rare bat species: implications of survey method and spatio-temporal sampling for monitoring bats.

    Science.gov (United States)

    Braun de Torrez, Elizabeth C; Wallrichs, Megan A; Ober, Holly K; McCleery, Robert A

    2017-01-01

    Due to increasing threats facing bats, long-term monitoring protocols are needed to inform conservation strategies. Effective monitoring should be easily repeatable while capturing spatio-temporal variation. Mobile acoustic driving transect surveys ('mobile transects') have been touted as a robust, cost-effective method to monitor bats; however, it is not clear how well mobile transects represent dynamic bat communities, especially when used as the sole survey approach. To assist biologists who must select a single survey method due to resource limitations, we assessed the effectiveness of three acoustic survey methods at detecting species richness in a vast protected area (Everglades National Park): (1) mobile transects, (2) stationary surveys that were strategically located by sources of open water and (3) stationary surveys that were replicated spatially across the landscape. We found that mobile transects underrepresented bat species richness compared to stationary surveys across all major vegetation communities and in two distinct seasons (dry/cool and wet/warm). Most critically, mobile transects failed to detect three rare bat species, one of which is federally endangered. Spatially replicated stationary surveys did not estimate higher species richness than strategically located stationary surveys, but increased the rate at which species were detected in one vegetation community. The survey strategy that detected maximum species richness and the highest mean nightly species richness with minimal effort was a strategically located stationary detector in each of two major vegetation communities during the wet/warm season.

  2. Knowledge and Practices of Toxoplasmosis among Clinical Laboratory Professionals: A Cross-Sectional Study in Durango, Mexico.

    Science.gov (United States)

    Alvarado-Esquivel, Cosme; Sánchez-Anguiano, Luis Francisco; Berumen-Segovia, Luis Omar; Hernández-Tinoco, Jesús; Rico-Almochantaf, Yazmin Del Rosario; Cisneros-Camacho, Alfredo; Cisneros-Martínez, Jorge Arturo

    2017-11-18

    Background : The aim of this study was to determine the level of knowledge and practices about toxoplasmosis in a sample of clinical laboratory professionals in Mexico. Methods : 192 clinical laboratory professionals were surveyed. They were asked about (1) Toxoplasma gondii ; (2) clinical manifestations, diagnosis, treatment, and epidemiology of toxoplasmosis; and (3) their practices with respect to toxoplasmosis. Results : The range of animals infected by T. gondii was known by 44.8% of participants. Clinical aspects of toxoplasmosis were known by up to 44.3% of subjects. Correct answers about the interpretation of serological markers of T. gondii infection were provided by up to 32.8% of participants. A minority (32.2%) of participants knew about a high number of false positive results of anti- T. gondii IgM antibody tests. Most participants (90.1%) did not know what the anti- T. gondii IgG avidity test was. Up to 55.7% of participants provided incorrect answers about the interpretation of serology tests for the treatment of pregnant women. Common routes of T. gondii infection were known by toxoplasmosis and a limited practice of laboratory tests among the professionals surveyed.

  3. Survey and assessment of conventional software verification and validation methods

    International Nuclear Information System (INIS)

    Miller, L.A.; Groundwater, E.; Mirsky, S.M.

    1993-04-01

    By means of a literature survey, a comprehensive set of methods was identified for the verification and validation of conventional software. The 134 methods so identified were classified according to their appropriateness for various phases of a developmental lifecycle -- requirements, design, and implementation; the last category was subdivided into two, static testing and dynamic testing methods. The methods were then characterized in terms of eight rating factors, four concerning ease-of-use of the methods and four concerning the methods' power to detect defects. Based on these factors, two measurements were developed to permit quantitative comparisons among methods, a Cost-Benefit metric and an Effectiveness Metric. The Effectiveness Metric was further refined to provide three different estimates for each method, depending on three classes of needed stringency of V ampersand V (determined by ratings of a system's complexity and required-integrity). Methods were then rank-ordered for each of the three classes in terms of their overall cost-benefits and effectiveness. The applicability was then assessed of each method for the four identified components of knowledge-based and expert systems, as well as the system as a whole

  4. Visual surveys of cetaceans conducted in the Bering, Chukchi, and Beaufort Seas by Alaska Fisheries Science Center, National Marine Mammal Laboratory from 2010-08-25 to 2015-09-28 (NCEI Accession 0137906)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — As part of several inter-agency agreements between the National Marine Mammal Laboratory (NMML) and the Bureau of Ocean Energy Management (BOEM), visual surveys of...

  5. Infections in British clinical laboratories, 1986-87.

    OpenAIRE

    Grist, N R; Emslie, J A

    1989-01-01

    During 1986-87 this continuing survey showed 15 specific infections in the staff of 235 laboratories, representing 28,524 person years of exposure. The community was the probable source of four of the five cases of tuberculosis and one of the five cases of salmonellosis. Occupational exposure was the probable cause of four infections by Shigella flexneri, three by Salmonella typhimurium, and one by S typhi, all affecting medical laboratory scientific officers (MLSOs) in microbiology. Occupati...

  6. Post-remedial-action radiological survey of the Westinghouse Advanced Reactors Division Plutonium Fuel Laboratories, Cheswick, Pennsylvania, October 1-8, 1981

    International Nuclear Information System (INIS)

    Flynn, K.F.; Justus, A.L.; Sholeen, C.M.; Smith, W.H.; Wynveen, R.A.

    1984-01-01

    The post-remedial-action radiological assessment conducted by the ANL Radiological Survey Group in October 1981, following decommissioning and decontamination efforts by Westinghouse personnel, indicated that except for the Advanced Fuels Laboratory exhaust ductwork and north wall, the interior surfaces of the Plutonium Laboratory and associated areas within Building 7 and the Advanced Fuels Laboratory within Building 8 were below both the ANSI Draft Standard N13.12 and NRC Guideline criteria for acceptable surface contamination levels. Hence, with the exceptions noted above, the interior surfaces of those areas within Buildings 7 and 8 that were included in the assessment are suitable for unrestricted use. Air samples collected at the involved areas within Buildings 7 and 8 indicated that the radon, thoron, and progeny concentrations within the air were well below the limits prescribed by the US Surgeon General, the Environmental Protection Agency, and the Department of Energy. The Building 7 drain lines are contaminated with uranium, plutonium, and americium. Radiochemical analysis of water and dirt/sludge samples collected from accessible Low-Bay, High-Bay, Shower Room, and Sodium laboratory drains revealed uranium, plutonium, and americium contaminants. The Building 7 drain lines hence are unsuitable for release for unrestricted use in their present condition. Low levels of enriched uranium, plutonium, and americium were detected in an environmental soil coring near Building 8, indicating release or spillage due to Advanced Reactors Division activities or Nuclear Fuel Division activities undr NRC licensure. 60 Co contamination was detected within the Building 7 Shower Room and in soil corings from the environs of Building 7. All other radionuclide concentrations measured in soil corings and the storm sewer outfall sample collected from the environs about Buildings 7 and 8 were within the range of normally expected background concentrations

  7. New Mexicans` images and perceptions of Los Alamos National Laboratory. Winter, 1992--1993

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-01-01

    This report uses survey data to profile New Mexico residents` images and perceptions of Los Alamos National Laboratory (LANL). The survey results are the responses of a representative, stratified random sample of 992 New Mexico households to a set of questions asked in October, 1992. The data allow statistical inference to the general population`s responses to the same set of questions at the time the survey was administered. The results provide an overview of New Mexico residents` current images and perceptions of the Laboratory. The sample margin of error is plus or minus 3.5% at the 95% confidence level.

  8. External quality-control surveys of peptide hormone radioimmunoassays in the Federal Republic of Germany. The present status

    International Nuclear Information System (INIS)

    Breuer, H.; Jungbluth, D.; Roehle, G.; Marschner, I.; Scriba, P.C.; Wood, W.G.

    1978-01-01

    Two types of quality-control survey (QCS) of hormone assays are performed in the Federal Republic of Germany. In the one survey, the participating laboratories are requested to determine seven or eight different hormones in two lyophilized sera that are distributed several times a year. Because of the lack of reference methods for peptide hormones, the statistical evaluation of the results indicates only whether they are ''correct'' or subject to systematic or nonsystematic errors with respect to the findings of the other participants. In the other survey, the participating laboratories are requested to assay only one given hormone in some 20 deep-frozen sera (including standards in hormone-free sera for derivation of a standard curve) that are distributed at relatively long intervals. The statistical analysis of the data derived from these QCSs allows - together with the methodological inquiry form - detection of probable causes for discrepancies in the results. (author)

  9. Procedures of Exercise Physiology Laboratories

    Science.gov (United States)

    Bishop, Phillip A.; Fortney, Suzanne; Greenisen, Michael; Siconolfi, Steven F.; Bamman, Marcas M.; Moore, Alan D., Jr.; Squires, William

    1998-01-01

    This manual describes the laboratory methods used to collect flight crew physiological performance data at the Johnson Space Center. The Exercise Countermeasures Project Laboratory is a standard physiology laboratory; only the application to the study of human physiological adaptations to spaceflight is unique. In the absence of any other recently published laboratory manual, this manual should be a useful document staffs and students of other laboratories.

  10. International survey on the use and welfare of zebrafish Danio rerio in research.

    Science.gov (United States)

    Lidster, K; Readman, G D; Prescott, M J; Owen, S F

    2017-05-01

    A survey was conducted regarding zebrafish Danio rerio use for scientific research with a focus on: anaesthesia and euthanasia; housing and husbandry; breeding and production; refinement opportunities. A total of 98 survey responses were received from laboratories in 22 countries in Europe, North America, South America, Asia and Australia. There appears a clear and urgent need to identify the most humane methods of anaesthesia and euthanasia. Aversive responses to MS-222 were widely observed raising concerns about the use of this anaesthetic for D. rerio. The use of anaesthesia in fin clipping for genetic identification is widely practised and there appears to be an opportunity to further develop less invasive methods and refine this process. Optimization (and potentially standardization) of feeding is an area for further investigation. Given that diet and body condition can have such profound effects on results of experiments, differences in practice could have significant scientific implications. Further research into transition between dark and light phases in the laboratory appears to represent an opportunity to establish best practice. Plants and gravel were not considered practical by many laboratories. The true value and benefits need to be established and communicated. Overproduction is a concern both from ethical and financial viewpoints. There is an opportunity to further reduce wastage of D. rerio. There are clear concerns and opportunities for the scientific community to work together to further improve the welfare of these important laboratory models. © 2017 The Authors. Journal of Fish Biology published by John Wiley & Sons Ltd on behalf of The Fisheries Society of the British Isles.

  11. Training practices of cell processing laboratory staff : Analysis of a survey by the Alliance for Harmonization of Cellular Therapy Accreditation

    NARCIS (Netherlands)

    Keever-Taylor, Carolyn A.; Slaper-Cortenbach, Ineke; Celluzzi, Christina; Loper, Kathy; Aljurf, Mahmoud; Schwartz, Joseph; Mcgrath, Eoin; Eldridge, Paul

    2015-01-01

    Background aims: Methods for processing products used for hematopoietic progenitor cell (HPC) transplantation must ensure their safety and efficacy. Personnel training and ongoing competency assessment is critical to this goal. Here we present results from a global survey of methods used by a

  12. Review of laboratory programs for women Points-of-Contact Committee

    Energy Technology Data Exchange (ETDEWEB)

    Duke, D.; Magrini, K. [comps.] [National Renewable Energy Lab., Golden, CO (United States); McLane, V. [comp.] [Brookhaven National Lab., Upton, NY (United States); Wieda, K. [comp.] [Pacific Northwest Lab., Richland, WA (United States)

    1995-06-01

    The mission of the DOE Review of Laboratory Programs for Women is to: provide DOE and its Laboratories with effective strategies, targeting women, for establishing aggressive outreach programs which improve the access of women to careers in science, engineering, and mathematics. Ensure that the Department and its Laboratories are exemplary places of employment by providing programs which enhance opportunity, remove barriers, and assist women in achieving full professional development. A survey of the DOE facilities was undertaken by the Points-of-Contact for the DOE Review of Laboratory Programs for Women in order to gather data to be used as a baseline against which to measure future progress. We plan to look at current programs already in place and evaluate them with a view to deciding which programs are most effective, and selecting model programs suitable for implementation at other facilities. The survey focused on four areas: statistical data, laboratory policy, formal and informal programs which affect the quality of life in the work environment, and career development and advancement, and educational programs. Although this report focuses on women, the problems discussed affect all DOE facility employees.

  13. Students' Perception of Self-Efficacy Following Medicinal Chemistry Skills Laboratory Exercises.

    Science.gov (United States)

    Alsharif, Naser Z; Roche, Victoria F; Qi, Yongyue

    2016-06-25

    Objective. To analyze student perceptions of self-efficacy in meeting medicinal chemistry course related educational outcomes and skills following a medicinal chemistry skills laboratory. Methods. Four activities were implemented in a pharmacy skills laboratory (PSL) for second-year pharmacy students. Students (n=121) worked individually on exercises for three of the four activities. Pre/post-laboratory surveys on self-efficacy were administered. The McNemar test was performed to evaluate students' self-efficacy above 70% related to course outcomes before and after the exercises in each activity. An independent t test was conducted to compare the mean of students' responses on meeting course outcomes based on the 70% anchor for the perspective confidence on meeting course outcomes. Results. The post-PSL scores on all self-efficacy questions improved. The majority of students reported skill development in all exercises. Students and clinical faculty qualitative responses indicated they felt exercises were effective. Conclusion. A PSL can serve as a valuable opportunity to address course related educational outcomes and specific skill development and can help students assess their self-efficacy in meeting them.

  14. Cursory radiological assessment: Battelle Columbus Laboratory Decommissioning and Decontamination Project

    International Nuclear Information System (INIS)

    Smith, W.H.; Munyon, W.J.; Mosho, G.D.; Robinet, M.J.; Wynveen, R.A.

    1988-10-01

    This document reports on the results obtained from a cursory radiological assessment of various properties at the Battelle Columbus Laboratory, Columbia, Ohio. The cursory radiological assessment is part of a preliminary investigation for the Battelle Columbus Laboratory Decommissioning and Decontamination Project. The radiological assessment of Battelle Columbus Laboratory's two sites included conducting interior and exterior building surveys and collecting and analyzing air, sewer system, and soil samples. Direct radiological surveys were made of floor, wall, and overhead areas. Smear surveys were made on various interior building surfaces as well as the exterior building vents. Air samples were collected in select areas to determine concentrations of Rn-222, Rn-220, and Rn-219 daughters, in addition to any long-lived radioactive particulates. Radon-222 concentrations were continuously monitored over a 24-hr period at several building locations using a radon gas monitoring system. The sanitary sewer systems at King Avenue, West Jefferson-North, and West Jefferson-South were each sampled at select locations. All samples were submitted to the Argonne Analytical Chemistry Laboratory for various radiological and chemical analyses. Environmental soil corings were taken at both the King Avenue and West Jefferson sites to investigate the potential for soil contamination within the first 12-inches below grade. Further subsurface investigations at the West Jefferson-North and West Jefferson-South areas were conducted using soil boring techniques. 4 refs., 10 figs., 10 tabs

  15. Continuing to Confront COPD International Patient Survey : methods, COPD prevalence, and disease burden in 2012-2013

    NARCIS (Netherlands)

    Landis, Sarah H.; Muellerova, Hana; Mannino, David M.; Menezes, Ana M.; Han, MeiLan K.; van der Molen, Thys; Ichinose, Masakazu; Aisanov, Zaurbek; Oh, Yeon-Mok; Davis, Kourtney J.

    2014-01-01

    Purpose: The Continuing to Confront COPD International Patient Survey aimed to estimate the prevalence and burden of COPD globally and to update findings from the Confronting COPD International Survey conducted in 1999-2000. Materials and methods: Chronic obstructive pulmonary disease (COPD)

  16. Photometric calibration of the COMBO-17 survey with the Softassign Procrustes Matching method

    Science.gov (United States)

    Sheikhbahaee, Z.; Nakajima, R.; Erben, T.; Schneider, P.; Hildebrandt, H.; Becker, A. C.

    2017-11-01

    Accurate photometric calibration of optical data is crucial for photometric redshift estimation. We present the Softassign Procrustes Matching (SPM) method to improve the colour calibration upon the commonly used Stellar Locus Regression (SLR) method for the COMBO-17 survey. Our colour calibration approach can be categorised as a point-set matching method, which is frequently used in medical imaging and pattern recognition. We attain a photometric redshift precision Δz/(1 + zs) of better than 2 per cent. Our method is based on aligning the stellar locus of the uncalibrated stars to that of a spectroscopic sample of the Sloan Digital Sky Survey standard stars. We achieve our goal by finding a correspondence matrix between the two point-sets and applying the matrix to estimate the appropriate translations in multidimensional colour space. The SPM method is able to find the translation between two point-sets, despite the existence of noise and incompleteness of the common structures in the sets, as long as there is a distinct structure in at least one of the colour-colour pairs. We demonstrate the precision of our colour calibration method with a mock catalogue. The SPM colour calibration code is publicly available at https://neuronphysics@bitbucket.org/neuronphysics/spm.git.

  17. The status of safety in the public high school chemistry laboratories in Mississippi

    Science.gov (United States)

    Lacy, Sarah Louise Trotman

    Since laboratory-based science courses have become an essential element of any science curriculum and are required by the Mississippi Department of Education for graduation, the chemistry laboratories in the public high schools in Mississippi must be safe. The purpose of this study was to determine: the safety characteristics of a high school chemistry laboratory; the perceived safety characteristics of the chemistry laboratories in public high schools in Mississippi; the basic safety knowledge of chemistry teachers in public high schools in Mississippi, where chemistry teachers in Mississippi gain knowledge about laboratory safety and instruction; if public high school chemistry laboratories in Mississippi adhere to recommended class size, laboratory floor space per student, safety education, safety equipment, and chemical storage; and the relationship between teacher knowledge of chemistry laboratory safety and the safety status of the laboratory in which they teach. The survey instrument was composed of three parts. Part I Teacher Knowledge consisted of 23 questions concerning high school chemistry laboratory safety. Part II Chemistry Laboratory Safety Information consisted of 40 items divided into four areas of interest concerning safety in high school chemistry laboratories. Part III Demographics consisted of 11 questions relating to teacher certification, experience, education, and safety training. The survey was mailed to a designated chemistry teacher in every public high school in Mississippi. The responses to Part I of the survey indicated that the majority of the teachers have a good understanding of knowledge about chemistry laboratory safety but need more instruction on the requirements for a safe high school chemistry laboratory. Less than 50% of the responding teachers thought they had received adequate preparation from their college classes to conduct a safe chemistry laboratory. According to the responses of the teachers, most of their high school

  18. Comparison of laboratory and field remote sensing methods to measure forage quality.

    Science.gov (United States)

    Guo, Xulin; Wilmshurst, John F; Li, Zhaoqin

    2010-09-01

    Recent research in range ecology has emphasized the importance of forage quality as a key indicator of rangeland condition. However, we lack tools to evaluate forage quality at scales appropriate for management. Using canopy reflectance data to measure forage quality has been conducted at both laboratory and field levels separately, but little work has been conducted to evaluate these methods simultaneously. The objective of this study is to find a reliable way of assessing grassland quality through measuring forage chemistry with reflectance. We studied a mixed grass ecosystem in Grasslands National Park of Canada and surrounding pastures, located in southern Saskatchewan. Spectral reflectance was collected at both in-situ field level and in the laboratory. Vegetation samples were collected at each site, sorted into the green grass portion, and then sent to a chemical company for measuring forage quality variables, including protein, lignin, ash, moisture at 135 °C, Neutral Detergent Fiber (NDF), Acid Detergent Fiber (ADF), Total Digestible, Digestible Energy, Net Energy for Lactation, Net Energy for Maintenance, and Net Energy for Gain. Reflectance data were processed with the first derivative transformation and continuum removal method. Correlation analysis was conducted on spectral and forage quality variables. A regression model was further built to investigate the possibility of using canopy spectral measurements to predict the grassland quality. Results indicated that field level prediction of protein of mixed grass species was possible (r² = 0.63). However, the relationship between canopy reflectance and the other forage quality variables was not strong.

  19. Comparison of Laboratory and Field Remote Sensing Methods to Measure Forage Quality

    Directory of Open Access Journals (Sweden)

    Zhaoqin Li

    2010-09-01

    Full Text Available Recent research in range ecology has emphasized the importance of forage quality as a key indicator of rangeland condition. However, we lack tools to evaluate forage quality at scales appropriate for management. Using canopy reflectance data to measure forage quality has been conducted at both laboratory and field levels separately, but little work has been conducted to evaluate these methods simultaneously. The objective of this study is to find a reliable way of assessing grassland quality through measuring forage chemistry with reflectance. We studied a mixed grass ecosystem in Grasslands National Park of Canada and surrounding pastures, located in southern Saskatchewan. Spectral reflectance was collected at both in-situ field level and in the laboratory. Vegetation samples were collected at each site, sorted into the green grass portion, and then sent to a chemical company for measuring forage quality variables, including protein, lignin, ash, moisture at 135 ºC, Neutral Detergent Fiber (NDF, Acid Detergent Fiber (ADF, Total Digestible, Digestible Energy, Net Energy for Lactation, Net Energy for Maintenance, and Net Energy for Gain. Reflectance data were processed with the first derivative transformation and continuum removal method. Correlation analysis was conducted on spectral and forage quality variables. A regression model was further built to investigate the possibility of using canopy spectral measurements to predict the grassland quality. Results indicated that field level prediction of protein of mixed grass species was possible (r2 = 0.63. However, the relationship between canopy reflectance and the other forage quality variables was not strong.

  20. Maintaining and assessing extended 9 test methods in accordance with ISO/IEC 17025: 2005 for Isotopes Hydrology Laboratory

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Tran Khanh Minh; Vu Hoai

    2016-01-01

    The ISO/IEC 17025:2005 ''General requirements for the competence of testing and calibration laboratories'' is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technique and management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed and maintain a quality management system in accordance with ISO/IEC 17025:2005. In 2013, Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO/IEC 17025:2005 with VILAS 670 accredited code. Scope of recognition is analyzed 14 parameters: F"-, Cl"-, NO_2"-, NO_3"-, Br"-, PO_4"3"-, SO_4"2"-, Li"+, Na"+, NH_4"+, K"+, Mg"2"+, Ca"2"+ and "3H in water by ion chromatography and liquid scintillator counting method. The laboratory has successfully implemented the task of maintaining quality management systems conform to ISO/IEC 17025: 2005 and expanded the scope of accreditation by 9 parameters in water: pH, EC, TSS, TDS, DO, BOD5, pH, Fe and Mn in 2015. (author)

  1. Irradiation probe and laboratory for irradiated material evaluation

    International Nuclear Information System (INIS)

    Smutny, S.; Kupca, L.; Beno, P.; Stubna, M.; Mrva, V.; Chmelo, P.

    1975-09-01

    The survey and assessment are given of the tasks carried out in the years 1971 to 1975 within the development of methods for structural materials irradiation and of a probe for the irradiation thereof in the A-1 reactor. The programme and implementation of laboratory tests of the irradiation probe are described. In the actual reactor irradiation, the pulse tube length between the pressure governor and the irradiation probe is approximately 20 m, the diameter is 2.2 mm. Temperature reaches 800 degC while the pressure control system operates at 20 degC. The laboratory tests (carried out at 20 degC) showed that the response time of the pressure control system to a stepwise pressure change in the irradiation probe from 0 to 22 at. is 0.5 s. Pressure changes were also studied in the irradiation probe and in the entire system resulting from temperature changes in the irradiation probe. Temperature distribution in the body of the irradiation probe heating furnace was determined. (B.S.)

  2. Quality assurance programs at the PNL calibrations laboratory

    International Nuclear Information System (INIS)

    Piper, R.K.; McDonald, J.C.; Fox, R.A.; Eichner, F.N.

    1993-03-01

    The calibrations laboratory at Pacific Northwest Laboratory (PNL) serves as a radiological standardization facility for personnel and environmental dosimetry and radiological survey instruments. As part of this function, the calibrations laboratory must maintain radiological reference fields with calibrations traceable to the National Institute of Standards and Technology (NIST). This task is accomplished by a combination of (1) sources or reference instruments calibrated at or by NIST, (2) measurement quality assurance (MQA) interactions with NIST, and (3) rigorous internal annual and quarterly calibration verifications. This paper describes a representative sample of the facilities, sources, and actions used to maintain accurate and traceable fields

  3. Communication methods and production techniques in fixed prosthesis fabrication: a UK based survey. Part 2: Production techniques

    Science.gov (United States)

    Berry, J.; Nesbit, M.; Saberi, S.; Petridis, H.

    2014-01-01

    Aim The aim of this study was to identify the communication methods and production techniques used by dentists and dental technicians for the fabrication of fixed prostheses within the UK from the dental technicians' perspective. This second paper reports on the production techniques utilised. Materials and methods Seven hundred and eighty-two online questionnaires were distributed to the Dental Laboratories Association membership and included a broad range of topics, such as demographics, impression disinfection and suitability, and various production techniques. Settings were managed in order to ensure anonymity of respondents. Statistical analysis was undertaken to test the influence of various demographic variables such as the source of information, the location, and the size of the dental laboratory. Results The number of completed responses totalled 248 (32% response rate). Ninety percent of the respondents were based in England and the majority of dental laboratories were categorised as small sized (working with up to 25 dentists). Concerns were raised regarding inadequate disinfection protocols between dentists and dental laboratories and the poor quality of master impressions. Full arch plastic trays were the most popular impression tray used by dentists in the fabrication of crowns (61%) and bridgework (68%). The majority (89%) of jaw registration records were considered inaccurate. Forty-four percent of dental laboratories preferred using semi-adjustable articulators. Axial and occlusal under-preparation of abutment teeth was reported as an issue in about 25% of cases. Base metal alloy was the most (52%) commonly used alloy material. Metal-ceramic crowns were the most popular choice for anterior (69%) and posterior (70%) cases. The various factors considered did not have any statistically significant effect on the answers provided. The only notable exception was the fact that more methods of communicating the size and shape of crowns were utilised for

  4. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    Directory of Open Access Journals (Sweden)

    Ulleberg Thomas

    2011-04-01

    Full Text Available Abstract Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods.

  5. Development of a microbiological method (heat treatment method) to confirm the irradiation of food samples in a blind trial of collaborating laboratories

    International Nuclear Information System (INIS)

    Takekawa, T.; Koshikawa, T.; Miyahara, M.

    2009-01-01

    A practical screening method is needed so that any laboratory can easily and cheaply distinguish between non-irradiated and irradiated food. We carried out a study last year based on the findings that the sensitivity of bacteria to heat-treatment rose when bacteria was damaged by the irradiation, and the possibility that the irradiation could be detected in certain processing conditions. This method consists of a first assessment based on a general viable cell count and the second assessment based on the difference in the number of bacteria before and after the heat-treatment. A joint research study among a number of laboratories was conducted this year on the detection method by examining the effect of the heat-treatment on viable cells that adhered to spices. From the results, we found that there are two kinds of spices. For one type, both the first and second assessment need to be done, and for the other only the first assessment should be done. Therefore, the target spice should be classified into either the type only requiring the first assessment or the type for which the second assessment must also be carried out. In that case, we were able to obtain a high correct answer rate

  6. Results of detailed ground geophysical surveys for locating and differentiating waste structures in waste management area 'A' at Chalk River Laboratories, Ontario

    International Nuclear Information System (INIS)

    Tomsons, D.K.; Street, P.J.; Lodha, G.S.

    1999-01-01

    Waste Management Area 'A' (WMA 'A'), located in the outer area of the Chalk River Laboratories (CRL) was in use as a waste burial site from 1946 to 1955. Waste management structures include debris-filled trenches, concrete bunkers and miscellaneous contaminated solid materials, and ditches and pits used for liquid dispersal. In order to update historical records, it was proposed to conduct detailed ground geophysical surveys to define the locations of waste management structures in WMA 'A', assist in planning of the drilling and sampling program to provide ground truth for the geophysics investigation and to predict the nature and locations of unknown/undefined shallow structures. A detailed ground geophysical survey grid was established with a total of 127 grid lines, oriented NNE and spaced one metre apart. The geophysical surveys were carried out during August and September, 1996. The combination of geophysical tools used included the Geonics EM61 metal detector, the GSM-19 magnetometer/gradiometer and a RAMAC high frequency ground penetrating radar system. The geophysical surveys were successful in identifying waste management structures and in characterizing to some extent, the composition of the waste. The geophysical surveys are able to determine the presence of most of the known waste management structures, especially in the western and central portions of the grid which contain the majority of the metallic waste. The eastern portion of the grid has a completely different geophysical character. While historical records show that trenches were dug, they are far less evident in the geophysical record. There is clear evidence for a trench running between lines 30E and 63E at 70 m. There are indications from the radar survey of other trench-like structures in the eastern portion. EM61 data clearly show that there is far less metallic debris in the eastern portion. The geophysical surveys were also successful in identifying previously unknown locations of waste

  7. [Implementation of the technical requirements of the UNE-EN-ISO 15189 quality standard in a mycobacterial laboratory].

    Science.gov (United States)

    Guna Serrano, M del Remedio; Ocete Mochón, M Dolores; Lahiguera, M José; Bresó, M Carmen; Gimeno Cardona, Concepción

    2013-02-01

    The UNE-EN-ISO 15189:2007 standard defines the requirements for quality and competence that must be met by medical laboratories. These laboratories should use this international standard to develop their own quality management systems and to evaluate their own competencies; in turn, this standard will be used by accreditation bodies to confirm or recognize the laboratories' competence. In clinical microbiology laboratories, application of the standard implies the implementation of the technical and specific management requirements that must be met to achieve optimal quality when carrying out microbiological tests. In Spain, accreditation is granted by the Spanish Accreditation Body (Entidad Nacional de Acreditación). This review aims to discuss the practical application of the standard's technical requirements in mycobacterial laboratory. Firstly, we define the scope of accreditation. Secondly, we specify how the items of the standard on personnel management, control of equipment, environmental facilities, method validation, internal controls and customer satisfaction surveys were developed and implemented in our laboratory. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  8. North Pacific right whale aerial surveys conducted in the southeastern Bering Sea by the Alaska Fisheries Scientific Center, National Marine Mammal Laboratory from 2008-07-24 to 2009-08-25 (NCEI Accession 0135767)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — As part of an inter-agency agreement between the National Marine Mammal Laboratory and the Bureau of Ocean Energy Management, aerial surveys of the North Aleutian...

  9. Survey of evaluation methods for thermal striping in FBR structures

    International Nuclear Information System (INIS)

    Miura, Naoki; Nitta, Akito; Take, Kohji

    1988-01-01

    In the upper core structures or the sodium mixing tee of Fast Breeder Reactors, sodium mixing streams which are at different temperatures produce rapid temperature fluctuations, namely 'thermal striping', upon component surfaces, and it is apprehended that the high-cycle thermal fatigue causes the crack initiation and propagation. The thermal striping is one of the factors which is considered in FBR component design, however, the standard evaluation method has not built up yet because of the intricacy of that mechanism, the difficulty of an actual proof, the lack of data, and so on. In this report, it is intended to survey of the datails and the present situation of the evaluation method of crack initiation and propagation due to thermal striping, and study the appropriate method which will be made use of the rationalization of design. So it is ascertained that the method which use a quantitative prediction of crack propagation is optimum to evaluate the thermal striping phenomenon. (author)

  10. U.S. residential consumer product information: Validation of methods for post-stratification weighting of Amazon Mechanical Turk surveys

    Energy Technology Data Exchange (ETDEWEB)

    Greenblatt, Jeffery B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yang, Hung-Chia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Desroches, Louis-Benoit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Young, Scott J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Beraki, Bereket [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Pratt, Stacy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Willem, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Donovan, Sally M. [Consultant, Melbourne (Australia)

    2013-04-01

    We present two post-stratification weighting methods to validate survey data collected using Amazon Mechanical Turk (AMT). Two surveys focused on appliance and consumer electronics devices were administered in the spring and summer of 2012 to each of approximately 3,000 U.S. households. Specifically, the surveys asked questions about residential refrigeration products, televisions (TVs) and set-top boxes (STBs). Filtered data were assigned weights using each of two weighting methods, termed “sequential” and “simultaneous,” by examining up to eight demographic variables (income, education, gender, race, Hispanic origin, number of occupants, ages of occupants, and geographic region) in comparison to reference U.S. demographic data from the 2009 Residential Energy Consumption Survey (RECS). Five key questions from the surveys (number of refrigerators, number of freezers, number of TVs, number of STBs and primary service provider) were evaluated with a set of statistical tests to determine whether either method improved the agreement of AMT with reference data, and if so, which method was better. The statistical tests used were: differences in proportions, distributions of proportions (using Pearson’s chi-squared test), and differences in average numbers of devices as functions of all demographic variables. The results indicated that both methods generally improved the agreement between AMT and reference data, sometimes greatly, but that the simultaneous method was usually superior to the sequential method. Some differences in sample populations were found between the AMT and reference data. Differences in the proportion of STBs reflected large changes in the STB market since the time our reference data was acquired in 2009. Differences in the proportions of some primary service providers suggested real sample bias, with the possible explanation that AMT user are more likely to subscribe to providers who also provide home internet service. Differences in

  11. Evaluation of the analytic performance of laboratories: inter-laboratorial study of the spectroscopy of atomic absorption

    International Nuclear Information System (INIS)

    Wong Wong, S. M.

    1996-01-01

    The author made an inter-laboratorial study, with the participation of 18 national laboratories, that have spectrophotometer of atomic absorption. To evaluate the methods of analysis of lead, sodium, potasium, calcium, magnesium, zinc, copper, manganese, and iron, in the ambit of mg/l. The samples, distributed in four rounds to the laboratories, were prepared from primary patterns, deionized and distilled water. The study evaluated the homogeneity and stability, and verified its concentration, using as a reference method, the spectrometry method of Inductively Coupled Plasma emission (1CP). To obtain the characteristics of analytic performance, it applied the norm ASTM E 691. To evaluated the analytic performance, it used harmonized protocol of the International Union of Pure and applied chemistry (IUPAC). The study obtained the 29% of the laboratories had a satisfactory analytic performance, 9% had a questionable performance and 62% made an unsatisfactory analytic performance, according to the IUPAC norm. The results of the values of the characteristic performance method, show that there is no intercomparability between the laboratories, which is attributed to the different methodologies of analysis. (S. Grainger)

  12. Constructivist Learning Environment During Virtual and Real Laboratory Activities

    Directory of Open Access Journals (Sweden)

    Ari Widodo

    2017-04-01

    Full Text Available Laboratory activities and constructivism are two notions that have been playing significant roles in science education. Despite common beliefs about the importance of laboratory activities, reviews reported inconsistent results about the effectiveness of laboratory activities. Since laboratory activities can be expensive and take more time, there is an effort to introduce virtual laboratory activities. This study aims at exploring the learning environment created by a virtual laboratory and a real laboratory. A quasi experimental study was conducted at two grade ten classes at a state high school in Bandung, Indonesia. Data were collected using a questionnaire called Constructivist Learning Environment Survey (CLES before and after the laboratory activities. The results show that both types of laboratories can create constructivist learning environments. Each type of laboratory activity, however, may be stronger in improving certain aspects compared to the other. While a virtual laboratory is stronger in improving critical voice and personal relevance, real laboratory activities promote aspects of personal relevance, uncertainty and student negotiation. This study suggests that instead of setting one type of laboratory against the other, lessons and follow up studies should focus on how to combine both types of laboratories to support better learning.

  13. Variation in interoperability across clinical laboratories nationwide.

    Science.gov (United States)

    Patel, Vaishali; McNamara, Lauren; Dullabh, Prashila; Sawchuk, Megan E; Swain, Matthew

    2017-12-01

    To characterize nationwide variation and factors associated with clinical laboratories': (1) capabilities to send structured test results electronically to ordering practitioners' EHR systems; and (2) their levels of exchange activity, as measured by whether they sent more than three-quarters of their test results as structured data to ordering practitioners' EHR systems. A national survey of all independent and hospital laboratories was conducted in 2013. Using an analytic weighted sample of 9382 clinical laboratories, a series of logistic regression analyses were conducted to identify organizational and area characteristics associated with clinical laboratories' exchange capability and activity. Hospital-based clinical laboratories (71%) and larger clinical laboratories (80%) had significantly higher levels of capability compared to independent (58%) and smaller laboratories (48%), respectively; though all had similar levels of exchange activity, with 30% of clinical laboratories sending 75% or more of their test results electronically. In multivariate analyses, hospital and the largest laboratories had 1.87 and 4.40 higher odds, respectively, of possessing the capability to send results electronically compared to independent laboratories (pLaboratories located in areas with a higher share of potential exchange partners had a small but significantly greater capability to send results electronically and higher levels of exchange activity(pClinical laboratories' capability to exchange varied by size and type; however, all clinical laboratories had relatively low levels of exchange activity. The role of exchange partners potentially played a small but significant role in driving exchange capability and activity. Published by Elsevier B.V.

  14. Fast and accurate methods of independent component analysis: A survey

    Czech Academy of Sciences Publication Activity Database

    Tichavský, Petr; Koldovský, Zbyněk

    2011-01-01

    Roč. 47, č. 3 (2011), s. 426-438 ISSN 0023-5954 R&D Projects: GA MŠk 1M0572; GA ČR GA102/09/1278 Institutional research plan: CEZ:AV0Z10750506 Keywords : Blind source separation * artifact removal * electroencephalogram * audio signal processing Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.454, year: 2011 http://library.utia.cas.cz/separaty/2011/SI/tichavsky-fast and accurate methods of independent component analysis a survey.pdf

  15. Powder X-ray diffraction laboratory, Reston, Virginia

    Science.gov (United States)

    Piatak, Nadine M.; Dulong, Frank T.; Jackson, John C.; Folger, Helen W.

    2014-01-01

    The powder x-ray diffraction (XRD) laboratory is managed jointly by the Eastern Mineral and Environmental Resources and Eastern Energy Resources Science Centers. Laboratory scientists collaborate on a wide variety of research problems involving other U.S. Geological Survey (USGS) science centers and government agencies, universities, and industry. Capabilities include identification and quantification of crystalline and amorphous phases, and crystallographic and atomic structure analysis for a wide variety of sample media. Customized laboratory procedures and analyses commonly are used to characterize non-routine samples including, but not limited to, organic and inorganic components in petroleum source rocks, ore and mine waste, clay minerals, and glassy phases. Procedures can be adapted to meet a variety of research objectives.

  16. Chemistry Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: To conduct fundamental studies of highway materials aimed at understanding both failure mechanisms and superior performance. New standard test methods are...

  17. The instruments in the first psychological laboratory in Mexico: antecedents, influence, and methods.

    Science.gov (United States)

    Escobar, Rogelio

    2014-11-01

    Enrique O. Aragón established the first psychological laboratory in Mexico in 1916. This laboratory was inspired by Wundt's laboratory and by those created afterward in Germany and the United States. It was equipped with state-of-the art instruments imported from Germany in 1902 from Ernst Zimmermann who supplied instruments for Wundt's laboratory. Although previous authors have described the social events leading to the creation of the laboratory, there are limited descriptions of the instruments, their use, and their influence. With the aid of archival resources, the initial location of the laboratory was determined. The analysis of instruments revealed a previously overlooked relation with a previous laboratory of experimental physiology. The influence of the laboratory was traced by describing the careers of 4 students, 3 of them women, who worked with the instruments during the first 2 decades of the 20th century, each becoming accomplished scholars. In addition, this article, by identifying and analyzing the instruments shown in photographs of the psychological laboratory and in 1 motion film, provides information of the class demonstrations and the experiments conducted in this laboratory.

  18. Buried waste remote survey of the Idaho National Engineering Laboratory subsurface disposal area

    International Nuclear Information System (INIS)

    Richardson, B.S.; Noakes, M.W.; Griebenow, B.E.; Josten, N.E.

    1991-01-01

    Burial site characterization is an important first step in the restoration of subsurface disposal sites. Testing and demonstration of technology for remote buried waste site characterization were performed at the Idaho National Engineering Laboratory (INEL) by a team from five US Department of Energy (DOE) laboratories. The US Army's Soldier Robot Interface Project (SRIP) vehicle, on loan to the Oak Ridge National Laboratory (ORNL), was used as a remotely operated sensor platform. The SRIP was equipped with an array of sensors including terrain conductivity meter, magnetometer, ground-penetrating radar (GPR), organic vapor detector, gamma-based radar detector, and spectrum analyzer. The testing and demonstration were successfully completed and provided direction for future work in buried waste site characterization

  19. The use of qualitative methods to inform Delphi surveys in core outcome set development.

    Science.gov (United States)

    Keeley, T; Williamson, P; Callery, P; Jones, L L; Mathers, J; Jones, J; Young, B; Calvert, M

    2016-05-04

    Core outcome sets (COS) help to minimise bias in trials and facilitate evidence synthesis. Delphi surveys are increasingly being used as part of a wider process to reach consensus about what outcomes should be included in a COS. Qualitative research can be used to inform the development of Delphi surveys. This is an advance in the field of COS development and one which is potentially valuable; however, little guidance exists for COS developers on how best to use qualitative methods and what the challenges are. This paper aims to provide early guidance on the potential role and contribution of qualitative research in this area. We hope the ideas we present will be challenged, critiqued and built upon by others exploring the role of qualitative research in COS development. This paper draws upon the experiences of using qualitative methods in the pre-Delphi stage of the development of three different COS. Using these studies as examples, we identify some of the ways that qualitative research might contribute to COS development, the challenges in using such methods and areas where future research is required. Qualitative research can help to identify what outcomes are important to stakeholders; facilitate understanding of why some outcomes may be more important than others, determine the scope of outcomes; identify appropriate language for use in the Delphi survey and inform comparisons between stakeholder data and other sources, such as systematic reviews. Developers need to consider a number of methodological points when using qualitative research: specifically, which stakeholders to involve, how to sample participants, which data collection methods are most appropriate, how to consider outcomes with stakeholders and how to analyse these data. A number of areas for future research are identified. Qualitative research has the potential to increase the research community's confidence in COS, although this will be dependent upon using rigorous and appropriate

  20. ABACC's laboratory intercomparison program

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Esteban, Adolfo; Almeida, Silvio G. de; Araujo, Radier M. de; Rocha, Zildete

    1996-01-01

    A Laboratory Intercomparison Program involving Brazilian and Argentine laboratories, with the special participation of New Brunswick Laboratory - DOE and IAEA Seibersdorf Safeguards Laboratory, was implanted by ABACC having as main purpose to qualify a network to provide analytical services to this Agency on its role as administrator of the Common System of Accountability and Control of Nuclear Materials. For the first round robin of this Program, 15 laboratories were invited to perform elemental analysis on UO 2 samples, by using any desired method. Thirteen confirmed the participation and 10 reported the results. After an evaluation of the results by using a Two-Way Variance Analysis applied to a nested error model, it was found that 5 of them deviate less than 0.1% from the reference value established for the UO 2 uranium contents, being thus situated within the limits adopted for the target values, while the remaining ones reach a maximal deviation of 0.44%. The outcome of this evaluation, was sent to the laboratories, providing them with a feedback to improve their performance by applying corrective actions to the detected sources of errors or bias related to the methods techniques and procedures. (author)