WorldWideScience

Sample records for survey instrument results

  1. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Veillette, Daniel R.; Shah, Sagar C.; O'Rielly, Grant V.; Baena Galle, Roberto; Van Altena, William F.

    2009-01-01

    First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope 9 The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

  2. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  3. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  4. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  5. Regulatory requirements on the calibration and use of survey instruments

    International Nuclear Information System (INIS)

    Domondon, D.B.

    1989-01-01

    Regulatory requirements on the provision, calibration and occasions of use of survey instruments are enumerated for a number of licensed activities. Two methods of calibrating survey instruments are described. Factors that must be taken into consideration in conducting calibrations, contents of calibration reports and of the sticker attached to the instrument which are needed for the correct use of the instrument are discussed. The precautions to be observed in order to insure correct use of survey instruments are described. (Auth.)

  6. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  7. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  8. Measurements with the new PHE neutron survey instrument

    International Nuclear Information System (INIS)

    Eakins, J.S.; Tanner, R.J.; Hager, L.G.

    2014-01-01

    A novel design of survey instrument has been developed to accurately estimate ambient dose equivalent from neutrons with energies in the range from thermal to 20 MeV. The device features moderating and attenuating layers to ease measurement of fast and intermediate energy neutrons, combined with guides that channel low-energy neutrons to the single, central detector. A prototype of this device has been constructed and exposed to a set of calibration fields: the resulting measured responses are presented and discussed here, and compared against Monte Carlo data. A simple simulated workplace neutron field has also been developed to test the device. Measured response data have been determined for a prototype design of neutron survey instrument, using facilities at PHE and NPL. In general, the results demonstrated good directional invariance and agreed well with data obtained by Monte Carlo modelling, raising confidence in the accuracy of the response characteristics expected for the device. A simple simulated workplace field has also been developed and characterised, and the performance of the device assessed in it: agreement between measured and modelled results suggests that the device would behave as anticipated in real workplace fields. These performances will be investigated further in the future, as the design makes the transition from a research prototype to a commercially available instrument. (authors)

  9. The Measurement of Sexual Harassment: Comparison of the Results of Three Different Instruments

    NARCIS (Netherlands)

    Junger, Marianne

    1990-01-01

    This study examines the results of three instruments developed to measure sexual harassment. Two instruments were used in the Dutch national victimization survey: an oral interview and a written questionnaire. Three issues will be discussed: (1) do both instruments produce the same victimization

  10. Measuring teamwork in health care settings: a review of survey instruments.

    Science.gov (United States)

    Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C

    2015-04-01

    Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.

  11. Digital readout alpha survey instrument

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1976-01-01

    A prototype solid-state digital readout alpha particle survey instrument has been designed and constructed. The meter incorporates a Ludlum alpha scintillator as a detector, digital logic circuits for control and timing, and a Digilin counting module with reflective liquid crystal display. The device is used to monitor alpha radiation from a surface. Sample counts are totalized over 10-second intervals and displayed digitally in counts per minute up to 19,999. Tests over source samples with counts to 15,600 cpm have shown the device to be rapid, versatile and accurate. The instrument can be fabricated in one man-week and requires about $835 in material costs. A complete set of drawings is included

  12. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  13. Results of an EMI/RFI plant survey

    International Nuclear Information System (INIS)

    Shankar, R.; Mollerus, F.J.

    1993-01-01

    This paper summarizes the results of a telephone survey to collect information concerning electromagnetic interference/radio frequency interference (EMI/RFI) problems primarily at nuclear power plants. The survey found that problem sources such as two-way radios and welding have been largely resolved by procedural control and use of sound-power phone systems. Additional investigation and testing appear appropriate for noise interference related to grounding of electrical equipment and instrumentation

  14. Economic instruments for obesity prevention: results of a scoping review and modified delphi survey

    Directory of Open Access Journals (Sweden)

    LaFrance Jeffrey

    2011-10-01

    Full Text Available Abstract Background Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity, and to make specific recommendations for the Canadian context. Methods Arksey and O'Malley's (2005 methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1 a structured literature search and review, and 2 consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Results Two key findings from the scoping review included 1 consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2 very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. Conclusions In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy

  15. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  16. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  17. International Energy Agency instrumented facilities survey for solar assisted low energy dwellings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-02-01

    Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

  18. Study Abroad Survey Instruments: A Comparison of Survey Types and Experiences

    Science.gov (United States)

    Durrant, Marie Bradshaw; Dorius, Cassandra Rasmussen

    2007-01-01

    This study examines different survey instruments used to assess the experiences of U.S. study abroad participants. The intended audience is international and area study practitioners interested in assessing study abroad programs through postprogram interviews. An interview with the top 20 universities for number of students sent on study abroad…

  19. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    Science.gov (United States)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  20. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  1. Proceedings of the workshop on radiation survey instruments and calibrations

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Vallario, E.J.; Murphy, B.L.

    1985-11-01

    The workshop was held to discuss two topics: first, a performance standard for radiation survey instruments and the potential for a testing program based on that standard; and second, a system of secondary standards laboratories to provide instrument calibrations and related services. Separate abstracts have been prepared for the individual presentations

  2. Chemical ionisation mass spectrometry: a survey of instrument technology

    International Nuclear Information System (INIS)

    Mather, R.E.; Todd, J.F.J.

    1979-01-01

    The purpose of this review is to survey the innovations and improvements which have been made in both instrumentation and methodology in chemical ionization mass spectrometry in the past ten years. (Auth.)

  3. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  4. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. International Survey on agriculture-climate change policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fernagut, M.; Priem, M.; Sorgeloos, L.

    2011-09-15

    The title study provides an international overview of agriculture-climate change policy instruments for the reduction of methane and nitrous oxide emissions. The aim of this study is to clarify how national and/or international agriculture-climate-policies could or should be instrumented during the coming three to five years to achieve significant emission reductions of methane and nitrous oxide in the Dutch agricultural sector by 2020. The study includes an international survey, a quick-scan inventory of useful and inspiring examples of policy and reduction measures to reduce non CO2 greenhouse gases. ERM used an approach consisting out of three phases. In the first phase countries were selected on the basis of emissions and Kyoto protocol targets. In the second phase policy measures of these countries were listed, based on publicly available national and international sources. In a third phase a sub-set of this selection was analyzed in-depth through communications with local focal points and additional review of policy documents, to enhance the understanding of context, impact and results of each of these policies and measures.

  6. Results of the 2013 CASE Europe Salary Survey

    Science.gov (United States)

    Paradise, Andrew

    2013-01-01

    CASE has conducted salary surveys to track trends in the profession and to help members benchmark salaries since 1982. Following CASE's major overhaul of the survey instrument and data collection system, CASE Europe fielded a European version of the salary survey for the second time in October 2012. All individual CASE Europe members at colleges,…

  7. Applications of Calendar Instruments in Social Surveys: a review

    NARCIS (Netherlands)

    Glasner, T.J.; Vaart, van der W.

    2009-01-01

    Retrospective reports in survey interviews and questionnaires are subject to many types of recall error, which affect completeness, consistency, and dating accuracy. Concerns about this problem have led to the development of so-called calendar instruments, or timeline techniques. These aided recall

  8. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Calibration of the GNU and HSREM neutron survey instruments

    International Nuclear Information System (INIS)

    Eakins, J.S.; Hager, L.G.; Leake, J.W.; Mason, R.S.; Tanner, R.J.

    2017-01-01

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  10. Calibration of the GNU and HSREM neutron survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    Eakins, J.S., E-mail: jonathan.eakins@phe.gov.uk [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Hager, L.G. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Leake, J.W.; Mason, R.S. [Sherwood Nutec Scientific Ltd., Kent (United Kingdom); Tanner, R.J. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2017-04-21

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  11. A survey on the VXIbus and validity analyses for instrumentation and control in NPPs

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Park, Won Man

    1997-06-01

    This document presents the technical status of the VXIbus system and its interface. VMEbus, while developed as a backplane for Motorola processors, can be used for data acquisition, control and other instrumentation applications. The VXIbus and its associated standard for form, fit, and electrical interface have simplified the process of putting together automated instrumentation systems. The VXIplug and play system alliance was founded in 1993, the alliance's charter to improve the effectiveness of VXI-based solutions by increasing ease-of-use and improving the interoperability of mainframes, computers, instrumentations, and software through open, multivendor standards and practices. This technical report surveys surveys the instrumentation and control in NPPs apply to the VXI-based instruments which are studied expendability, interoperability, maintainability and other features. (author). 10 refs., 4 tabs., 25 figs

  12. Early results from the Whisper instrument on Cluster: An overview

    DEFF Research Database (Denmark)

    Decreau, P.M.E.; Fergeau, P.; Krasnoselskikh, V.

    2001-01-01

    The Whisper instrument yields two data sets: (i) the electron density determined via the relaxation sounder, and (ii) the spectrum of natural plasma emissions in the frequency band 2-80 kHz. Both data sets allow for the three-dimensional exploration of the magnetosphere by the Cluster mission...... the drift velocity of density structures. Wave observations are also of crucial interest for studying small-scale structures, as demonstrated in an example in the fore-shock region. Early results from the Whisper instrument are very encouraging, and demonstrate that the four-point Cluster measurements...... largely overcomes the limited telemetry allocation. The natural emissions are usually related to the plasma frequency, as identified by the sounder, and the combination of an active sounding operation and a passive survey operation provides a time resolution for the total density determination of 2.2 s...

  13. Human factors survey of advanced instrumentation and controls

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    A survey oriented towards identifying the human factors issues in regard to the use of advanced instrumentation and controls (I ampersand C) in the nuclear industry was conducted. A number of United States (US) and Canadian nuclear vendors and utilities were participants in the survey. Human factors items, subsumed under the categories of computer-generated displays (CGD), controls, organizational support, training, and related topics, were discussed. The survey found the industry to be concerned about the human factors issues related to the implementation of advanced I ampersand C. Fifteen potential human factors problems were identified. They include: the need for an advanced I ampersand C guideline equivalent to NUREG-0700; a role change in the control room from operator to supervisor; information overload; adequacy of existing training technology for advanced I ampersand C; and operator acceptance and trust. 11 refs., 1 tab

  14. A Survey Instrument for Measuring the Experiential Value of Employee-Tourist Encounters

    DEFF Research Database (Denmark)

    Mattsson, Jan; Sørensen, Flemming; Jensen, Jens Friis

    In this paper, we develop and test a survey instrument that aims at estimating the experiential value of employee-tourist encounters in destination-based tourism companies, as well as the characteristics of encounters that affect such experiential value. We suggest that such an instrument can...... for their visitors, rather than simply delivering service quality....

  15. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    Directory of Open Access Journals (Sweden)

    Laura Florence Harris

    Full Text Available Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision.A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana.The model posits three domains of conscientious objection that form the basis for the survey instrument: 1 beliefs about abortion and conscientious objection; 2 actions related to conscientious objection and abortion; and 3 self-identification as a conscientious objector.The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  16. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  17. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  18. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  19. Human factors survey of advanced instrumentation and controls technologies in nuclear plants

    International Nuclear Information System (INIS)

    Carter, R.J.

    1992-01-01

    A survey of advanced instrumentation and controls (I ampersand C) technologies and associated human factors issues in the US and Canadian nuclear industries was carried out by a team from Oak Ridge national laboratory to provide background for the development of regulatory policy, criteria, and guides for review of advanced I ampersand C systems as well as human engineering guidelines for evaluating these systems. The survey found those components of the US nuclear industry surveyed to be quite interested in advanced I ampersand C, but very cautious in implementing such systems in nuclear facilities and power plants. The trend in the facilities surveyed is to experiment cautiously when there is an intuitive advantage or short-term payoff. In the control room, the usual practice is direct substitution of digital and microprocessor-based instruments or systems that are functionally identical to the analog instruments or systems being replaced. The most advanced I ampersand C systems were found in the Canadian CANDU plants, where the newest plant has digital system in almost 100% of its control systems and in over 70% of its plant protection system. The hypothesis that properly 'introducing digital systems increases safety' is supported by the Canadian experience. The performance of these digital systems was achieved using an appropriate quality assurance program for the software development. The ability of digital systems to detect impending failures and initiate a fail-safe action, is a significant safety issue that should be of special interest to every US utility as well as to the US Nuclear Regulatory Commission. (orig.)

  20. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    CERN Document Server

    Lu Cun Heng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving cou...

  1. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  2. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    Science.gov (United States)

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  3. Identifying the Barriers to Using Games and Simulations in Education: Creating a Valid and Reliable Survey Instrument

    Science.gov (United States)

    Justice, Lenora Jean

    2012-01-01

    The purpose of this study was to create a valid and reliable instrument to measure teacher perceived barriers to the adoption of games and simulations in instruction. Previous research, interviews with educators, a focus group, an expert review, and a think aloud protocol were used to design a survey instrument. After finalization, the survey was…

  4. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  5. Development and validation of a survey instrument to measure children's advertising literacy

    NARCIS (Netherlands)

    Rozendaal, E.; Opree, S.J.; Buijzen, M.A.

    2016-01-01

    The aim of this study was to develop and validate a survey measurement instrument for children's advertising literacy. Based on the multidimensional conceptualization of advertising literacy by 0056"> Rozendaal, Lapierre, Van Reijmersdal, and Buijzen (2011), 39 items were created to measure two

  6. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    Science.gov (United States)

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  7. Work-nonwork interference: Preliminary results on the psychometric properties of a new instrument

    Directory of Open Access Journals (Sweden)

    Eileen Koekemoer

    2010-11-01

    Research purpose: The objectives of this study were to investigate the internal validity (construct, discriminant and convergent validity, reliability and external validity (relationship with theoretically relevant variables, including job characteristics, home characteristics, burnout, ill health and life satisfaction of the instrument. Motivation for the study: Work-family interaction is a key topic receiving significant research attention. In order to facilitate comparison across work-family studies, the use of psychometrically sound instruments is of great importance. Research design, approach and method: A cross-sectional survey design was used for the target population of married employees with children working at a tertiary institution in the North West province (n = 366. In addition to the new instrument, job characteristics, home characteristics, burnout, ill health and life satisfaction were measured. Main findings: The results provided evidence for construct, discriminant and convergent validity, reliability and significant relations with external variables. Practical/managerial implications: The new instrument can be used by researchers and managers as a test under development to investigate the interference between work and different nonwork roles (i.e. parental role, spousal role, work role, domestic role and specific relations with antecedents (e.g. job/home characteristics and well-being (e.g. burnout, ill health and life satisfaction. Contribution/value-add: This study provides preliminary information on the psychometric properties of a new instrument that measures the interference between work and nonwork.

  8. Planck 2013 results. VI. High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143,217, 353, 545......, these two high frequency channels are calibrated to within 5% and the 353 GHz channel to the percent level. The 100 and217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50

  9. Assessing the Learning Environment for Medical Students: An Evaluation of a Novel Survey Instrument in Four Medical Schools.

    Science.gov (United States)

    Pololi, Linda H; Evans, Arthur T; Nickell, Leslie; Reboli, Annette C; Coplit, Lisa D; Stuber, Margaret L; Vasiliou, Vasilia; Civian, Janet T; Brennan, Robert T

    2017-06-01

    A practical, reliable, and valid instrument is needed to measure the impact of the learning environment on medical students' well-being and educational experience and to meet medical school accreditation requirements. From 2012 to 2015, medical students were surveyed at the end of their first, second, and third year of studies at four medical schools. The survey assessed students' perceptions of the following nine dimensions of the school culture: vitality, self-efficacy, institutional support, relationships/inclusion, values alignment, ethical/moral distress, work-life integration, gender equity, and ethnic minority equity. The internal reliability of each of the nine dimensions was measured. Construct validity was evaluated by assessing relationships predicted by our conceptual model and prior research. Assessment was made of whether the measurements were sensitive to differences over time and across institutions. Six hundred and eighty-six students completed the survey (49 % women; 9 % underrepresented minorities), with a response rate of 89 % (range over the student cohorts 72-100 %). Internal consistency of each dimension was high (Cronbach's α 0.71-0.86). The instrument was able to detect significant differences in the learning environment across institutions and over time. Construct validity was supported by demonstrating several relationships predicted by our conceptual model. The C-Change Medical Student Survey is a practical, reliable, and valid instrument for assessing the learning environment of medical students. Because it is sensitive to changes over time and differences across institution, results could potentially be used to facilitate and monitor improvements in the learning environment of medical students.

  10. Survey and analysis on environmental and electromagnetic effect on instrumentation and control equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Koo; Lee, Dong Young; Cha, Kyung Ho

    2001-03-01

    As the instrumentation and control (I and C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrumentation and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment for I and C systems of nuclear power plants raises several concerns which have not been considered in conventional analog I and C equipment. The two major examples of the issues of digital systems are environmental/electromagnetic compatibility (EMC) and software reliability. This report presents the survey and research results on environmental and electromagnetic effect on I and C equipment of nuclear power plants to give a guideline for aging management and design process. Electromagnetic site surveys were conducted to be used as a part of technical basis to demonstrate that I and C systems are compatible with the ambient electromagnetic noise in Korean nuclear power plants.

  11. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    International Nuclear Information System (INIS)

    Lu Cunheng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving count rate (derived from total receiving count rate of the bottom and side surface). Finally, according to the measuring value, it is proved that imitating the change of total receiving gamma ray exposure rate of the bottom and side surfaces with this regularity in a certain high area is feasible

  12. Aquarius: The Instrument and Initial Results

    Science.gov (United States)

    Vine, David M Le; Lagerloef, G.S.E.; Ruf, C.; Wentz, F.; Yueh, S.; Piepmeier, J.; Lindstrom, E.; Dinnat, E.

    2012-01-01

    Aquarius was launched on June 10, 2011 aboard the Aquarius/SAC-D observatory and the instrument has been operating continuously since the initial turned-on was completed on August 25. The initial observed antenna temperatures were close to predicted and the first salinity map was released in September. In order to map the ocean salinity field, Aquarius includes several special features such as the inclusion of a scatterometer to provide a roughness correction, measurement of the third Stokes parameter to correct for Faraday rotation, and fast sampling to mitigate the effects of RFI. This paper provides an overview of the instrument and an example of initial results. Details are covered in subsequent papers in the session on Aquarius

  13. First Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-01-01

    Considerable effort in the astronomy education research over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing astronomy as a sub-discipline of physics education research, allowing researchers to establish the initial knowledge state of students as well as to attempt to measure some of the impacts of innovative instructional interventions. Before now, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. Moving beyond the 10-year old Astronomy Diagnostics Test, we have developed and validated a new assessment instrument that is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this multiple-choice instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  14. Marine oil pollution and beached bird surveys: the development of a sensitive monitoring instrument

    International Nuclear Information System (INIS)

    Camphuysen, C.J.; Heubeck, M.

    2001-01-01

    One of the most obvious adverse effects of (chronic) pollution of the world's oceans and seas with mineral oil is the mortality of seabirds. Systematic surveys of beachcast corpses of birds ('beached bird surveys') have been used in many parts of the world to document the effect of oil pollution, but particularly so in Western Europe and in parts of North America. In this paper, the history, current schemes, methods and possible (future) use of beached bird surveys are described and discussed, because the value of beached bird surveys has been hotly disputed. Oil pollution is known since the late 19 th century, while the first beached bird surveys were conducted in the 1920s. Due to the amount of man-power needed for these surveys, most beached bird survey programs thrived only through the work of a large number of volunteers. However, most programs have resulted in substantial amounts of high quality data, often covering many consecutive years. One of the main shortcomings of many beached bird survey programs was the emphasis on stranded bird numbers rather than on relative measures, such as oil rates (percentage of corpses oiled of all corpses found). Sources of pollution, particularly so in chronically polluted regions such as the North Sea, the Baltic, the Mediterranean and the waters around Newfoundland, are insufficiently known, but could be studied through a sampling program connected to beached bird surveys. Suggestions for standardization of methods are presented, which could lead to a global and highly sensitive monitoring instrument of marine oil pollution. (Author)

  15. Competitiveness of firms, performance and customer orientation measures – empirical survey results

    Directory of Open Access Journals (Sweden)

    Alena Klapalová

    2011-01-01

    Full Text Available The purpose of this paper is to presents results from two empirical surveys concerning selected factors which can be connected to customer orientation, performance and competitiveness of firms. The purpose of the surveys was also to reveal potential differences between sectors arising from not only the different influences of internal but as well as external environment. A survey instrument was developed to analyse the relationship between several variables measuring customer orientation of surveyed firms and between these factors and level of financial performance. Several statistical methods were applied to analyse the data, specifically descriptive statistics (means and standard deviations, one-way analysis of variance (ANOVA with Bonferroni post-hoc test using financial performance for clustering firms and for assessment of potential differences of customer orientation criteria evaluation and Spearman rank correlation coefficients to assess the linear bivariate relationship between customer orientation variables. The results of ANOVA show that only the innovativeness is distinctive distinguishing criteria in conformity with the indicators of financial prosperity and that there are some differences between companies from two groups of sectors within the managers’ perception of customer orientation criteria performance.

  16. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    Science.gov (United States)

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  17. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  18. Performance specifications for health physics instrumentation: portable instrumentation for use in normal work environments. Part 2. Test results

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Stoetzel, G.A.; Selby, J.M.

    1986-09-01

    The Pacific Northwest Laboratory evaluated a draft American National Standards Institute Standard N42.17 (ANSI N42.17) on performance specifications for health physics instrumentation through a project jointly funded by the US Department of Energy and the US Nuclear Regulatory Commission. The evaluation involved testing a representative cross section of instruments against criteria in the standard. This report presents results of the testing program. A brief history of the project is included in the introduction. The instrumentation tested is described in general terms (i.e., types, ranges); however, no direct relationship between the results and a specific instrument model is made in this report. Testing requirements in ANSI N42.17D4, Revision 1 (May 1985) are summarized and the methods by which the tests are performed are discussed. Brief descriptions of the testing equipment are included in the methods section of the report. More detailed information about the draft standard, testing requirements and procedures, and the test equipment is included in ''Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Normal Work Environments, Part 1: Manual of Testing Procedures.'' Results of testing are given in two formats: test-by-test and instrument-by-instrument. Discussion is included on significant and interesting findings, on comparisons of results from the same type of instruments from same and different manufacturers, and on data grouped by manufacturer. Conclusions are made on the applicability and practicality of the proposed standard and on instrument performance. Changes that have been made to the proposed standard based on findings of the testing program are listed and discussed. 22 refs., 11 figs., 77 tabs

  19. Why might forest companies certify? Results from a Canadian survey

    NARCIS (Netherlands)

    Takahashi, T.; Kooten, van G.C.; Vertinsky, I.

    2003-01-01

    During the late 1980s/early 1990s, voluntary forest certification emerged as a new market-based incentive mechanism and had an important influence on the way the world's forests are managed. To understand the mechanism of its diffusion, we employed a survey instrument and probit regression analysis

  20. Inexpensive microwave survey instruments: an evaluation

    International Nuclear Information System (INIS)

    Herman, W.A.; Witters, D.M. Jr.

    1979-11-01

    Instruments were tested. Depending upon the oven modulation and leak location these tests show that the Micromate will yield a warning reading at levels from 0.6 to 1.9 mW/cm 2 , when the effects of modulation sensitivity and polarization ellipticity are considered. It is to be expected, then, that this instrument will yield warning readings even when the oven emission being measured lies well within applicable standards. Its apparent susceptibility to overload damage, however, could decrease its sensitivity with no clue to the user as to what had happened. Given the same considerations and parameters, the tests show that the Guard-Rod will yield a warning reading at levels from 3.7 to 47 mW/cm 2 , depending on which measurement surface is used. This instrument will sometimes yield warnings for oven emissions lying within applicable standards, and sometimes will fail to yield such warnings for emissions 10 times greater than allowable levels. The same considerations show that the Interceptor/Microscan units will light up at levels from as low as 0.7 to 0.8 mW/cm 2 or may require levels of 7 to 9 mW/cm 2 . At levels of 28 to 52 mW/cm 2 or higher, however, the warning LED does not light. If part of the field is cross-polarized, this threshold of extinction may be greater. In any case, there is no apparent way for the user to discern the presence of some potentially hazardous fields, and no way to distinguish such fields from a very low-level field. In summary, instruments of the Interceptor/Microscan design may light up at very low power densities, but fail to light at very high power densities. Clearly, this characteristic is extremely undesirable and potentially dangerous to a user relying on such a device.All of these values assume that the instruments are used in accordance with manufacturer's instructions. Otherwise, results may be worse. Moreover, the range of values given take little or no account of unit-to-unit variation, which may be considerable

  1. Two new portable survey instruments: the field phoswich detector and the Wee Pee Pee

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1978-01-01

    As part of a continuing program to upgrade the health physics survey instrumentation at Los Alamos, we have recently developed two new portable instruments. The first is a fully portable phoswich detector for low energy photons from small amounts of plutonium and americium in the field. The instrument has a background that is 2 to 3 times lower than an equivalent thin NaI detector. The instrument features an aural popper, analogue rate meter, and timer/scaler with liquid crystal display. The second instrument, called the ''Wee Pee Wee,'' is an alpha air proportional probe with complete electronics and readout package mounted on the probe itself. The entire package has a mass of 0.66 kg (1.45 lb) and is carried and operated in one hand. For monitoring shoes and other places where it is difficult to read the count-rate meter, the meter is made detachable for clipping to a shirt pocket, etc. An audio popper, range scales to 100 K cpm, and visual checks for high voltage and battery levels are also included

  2. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  3. New-generation low-power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Wolf, M.A.; Trujillo, F.; Umbarger, C.J.

    1983-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and power-saving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  4. New generation low power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Umbarger, C.J.; Wolf, M.A.

    1984-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and powersaving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Use of a capacitor as a power source eliminates many problems commonly associated with battery-operated instruments, such as having to open the case to change batteries, battery storage life, availability of batteries in the field, and some savings in weight. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  5. Design and use of concrete pads for the calibration of radiometric survey instrumentation

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint

  6. Retirement Applicant Satisfaction Survey Results

    Data.gov (United States)

    Social Security Administration — This dataset contains information about the Retirement Applicant Survey (RAS). The survey measured satisfaction results with the retirement application process. The...

  7. Intuitive risk perception: research results of attitude surveys toward risk and technology

    International Nuclear Information System (INIS)

    Renn, O.; Peters, H.P.

    1982-01-01

    Using the instruments of the empirical social sciences, a cross-section study was conducted comprising experiments on qualitative risk characteristics, in-depth interviews on mechanisms of risk perception and representative surveys of the public on technical risk sources, in particular with regard to nuclear energy. The results of these studies show that person-related expectations in respect of risk consequences, the possibility of personal influencing control, the severity of risk consequences and one's own risk propensity play a significant role in the evaluation of risks

  8. Monitoring the Future 2014 Survey Results

    Science.gov (United States)

    ... Statistics » Infographics » Monitoring the Future 2014 Survey Results Monitoring the Future 2014 Survey Results Email Facebook Twitter ... embed/iQDhYlYp81c?rel=0 Text Description of Infographic Monitoring the Future is an annual survey of 8th, ...

  9. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  10. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    Science.gov (United States)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  11. FY 2000 report on the results of the research and development project for the photon-aided instrumentation and processing technologies. R and D of the photon-aided instrumentation and processing technologies; 2000 nendo photon keisoku kako gijutsu seika hokokusho. Photon keisoku kako gijutsu no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 2000 results of development of the photon-aided instrumentation and processing technologies. The technological and R and D trends of the photon-aided instrumentation and processing technologies are surveyed, in order to clarify the directions of their impacts and ripple effects on creation of new industries and development of the existing industries. The survey committee is organized, for exchanging opinions and information, and collection of information. For the trends of the photon-aided processing technologies, information on the elementary and peripheral technologies is collected by literature survey and academic meetings for processing, applied instrumentation and analysis, and photon generation/controlling, to grasp, analyze and study the latest trends. For the photon-utilizing technologies, information is collected viewed from their application to wide industrial areas, e.g., medical, diagnostic, communication/transmission, multimedia and chemical areas, other than those for instrumentation and processing. Also surveyed and analyzed/studied are the technologies for environmental protection, sensing, information, and the new areas, e.g., terahertz photonics and agriculture. (NEDO)

  12. Research in radiation monitoring survey instrumentation. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Kennedy, E.J.; Phillips, R.G.; Walker, E.W. Jr.

    1978-01-01

    Two low-power solid-state prototype readout units were developed, an LED display and a LCD display. This display output was in a bar-graph format, covering four-decades of information, with 10-segments per decade. The displays accept a frequency input, which is standardly available from several portable radiation-survey instruments. Both readout units will operate on two D-cell batteries (3.0 Volt), with a typical current drain requirement of 0.3 MA for the LED display and 30μA for the LCD display. A wide-range electrometer circuit was also developed. The circuit covers an input current range from 10 -13 A to 10 -8 A. The output signal is a pulse whose frequency is directly proportional to input current. The circuit requires no high-megohm resistors, and is autoranging. Several candidate input amplifiers were analyzed and evaluated for use with the electrometer circuit

  13. Evaluation and Monte Carlo modelling of the response function of the Leake neutron area survey instrument

    International Nuclear Information System (INIS)

    Tagziria, H.; Tanner, R.J.; Bartlett, D.T.; Thomas, D.J.

    2004-01-01

    All available measured data for the response characteristics of the Leake counter have been gathered together. These data, augmented by previously unpublished work, have been compared to Monte Carlo simulations of the instrument's response characteristics in the energy range from thermal to 20 MeV. A response function has been derived, which is recommended as the best currently available for the instrument. Folding this function with workplace energy distributions has enabled an assessment of the impact of this new response function to be made. Similar work, which will be published separately, has been carried out for the NM2 and the Studsvik 2202D neutron area survey instruments

  14. Preventive maintenance instrumentation results in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Curiel, M.; Palomo, M. J.; Verdu, G.; Arnaldos, A.

    2010-10-01

    This paper is a recompilation of the most significance results in relation to the researching in preventive and predictive maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and the Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the power plants control and instrumentation department's technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the object to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish nuclear power plants each of them shall give a significant contribution to problem resolution and power plant performance. (Author)

  15. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service.

    Science.gov (United States)

    Crossno, J E; Berkins, B; Gotcher, N; Hill, J L; McConoughey, M; Walters, M

    2001-04-01

    In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas.

  16. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review.

    Science.gov (United States)

    Patterson, P Daniel; Weaver, Matthew D; Fabio, Anthony; Teasley, Ellen M; Renn, Megan L; Curtis, Brett R; Matthews, Margaret E; Kroemer, Andrew J; Xun, Xiaoshuang; Bizhanova, Zhadyra; Weiss, Patricia M; Sequeira, Denisse J; Coppler, Patrick J; Lang, Eddy S; Higgins, J Stephen

    2018-02-15

    This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. A systematic review study design was used and searched six databases, including one website. The research question guiding the search was developed a priori and registered with the PROSPERO database of systematic reviews: "Are there reliable and valid instruments for measuring fatigue among EMS personnel?" (2016:CRD42016040097). The primary outcome of interest was criterion-related validity. Important outcomes of interest included reliability (e.g., internal consistency), and indicators of sensitivity and specificity. Members of the research team independently screened records from the databases. Full-text articles were evaluated by adapting the Bolster and Rourke system for categorizing findings of systematic reviews, and the rated data abstracted from the body of literature as favorable, unfavorable, mixed/inconclusive, or no impact. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology was used to evaluate the quality of evidence. The search strategy yielded 1,257 unique records. Thirty-four unique experimental and non-experimental studies were determined relevant following full-text review. Nineteen studies reported on the reliability and/or validity of ten different fatigue survey instruments. Eighteen different studies evaluated the reliability and/or validity of four different sleepiness survey instruments. None of the retained studies reported sensitivity or specificity. Evidence quality was rated as very low across all outcomes. In this systematic review, limited evidence of the reliability and validity of 14 different survey instruments to assess the fatigue and/or sleepiness status of EMS personnel and related shift worker groups was identified.

  17. Preventive maintenance instrumentation results in Spanish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Palomo, M. J.; Verdu, G. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Arnaldos, A., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    This paper is a recompilation of the most significance results in relation to the researching in preventive and predictive maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and the Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the power plants control and instrumentation department's technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the object to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish nuclear power plants each of them shall give a significant contribution to problem resolution and power plant performance. (Author)

  18. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  19. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service*†

    Science.gov (United States)

    Crossno, Jon E.; Berkins, Brenda; Gotcher, Nancy; Hill, Judith L.; McConoughey, Michelle; Walters, Mitchel

    2001-01-01

    Objectives: In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Methods: Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results: Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. Conclusions: ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas. PMID:11337948

  20. Is It Working? Distractor Analysis Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-05-01

    The Test Of Astronomy STandards (TOAST) assessment instrument is a multiple-choice survey tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) have been conducting a question-by-question distractor analysis procedure to determine the sensitivity and effectiveness of each item. In brief, the frequency each possible answer choice, known as a foil or distractor on a multiple-choice test, is determined and compared to the existing literature on the teaching and learning of astronomy. In addition to having statistical difficulty and discrimination values, a well functioning assessment item will show students selecting distractors in the relative proportions to how we expect them to respond based on known misconceptions and reasoning difficulties. In all cases, our distractor analysis suggests that all items are functioning as expected. These results add weight to the validity of the Test Of Astronomy STandards (TOAST) assessment instrument, which is designed to help instructors and researchers measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  1. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  2. Practical guidelines for developing a smartphone-based survey instrument

    DEFF Research Database (Denmark)

    Ohme, Jakob; de Vreese, Claes Holger; Albæk, Erik

    The increasing relevance of mobile surveys makes it important to gather empirical evidence on designs of such surveys. This research note presents the results of a test study conducted to identify the best set-up for a smartphone-based survey. We base our analysis on a random sample of Danish...

  3. Quality of persian addiction websites: a survey based on silberg, discern and wqet instruments (2011).

    Science.gov (United States)

    Zahedi, Razieh; Taheri, Behjat; Shahrzadi, Leila; Tazhibi, Mehdi; Ashrafi-rizi, Hasan

    2013-03-01

    Nowadays, World Wide Web is an accessible and widespread resource to attain medical information. So physicians and health institutions try to inform patients about different domains of medicine through Web. Addiction is a noteworthy subject in medicine and a controversial issue among them. However, quality of health information on the internet is doubtful. The objective of this study is to determine the quality of Persian addiction websites to offer recommendation for their improvement. This was survey and an applied study that the study population was all Persian addiction websites. Sample of this study was 28 Persian addiction website which were chosen by searching Persian equivalences of 7 key terms (addiction, addict, addiction center, drug, treatment of addiction, recovery of addiction, addiction withdrawal) into the Google and Yahoo search engines. Finally, the websites were ranked based on the Silberg, DISCERN and WQET instruments. Data were analyzed with Excel software using descriptive statistics. The overall mean of websites in Silberg, DISCERN and WQET instruments were 1.42, 41.89, 64.57. Also the results showed that "Unit of Substance Abuse Treatment" belonging to Mashhad University of Medical Sciences was ranked first based on the Silberg, DISCERN and WQET instruments. 5 (from total of 9), 60 (from total of 80) and 82 (from total of normalized grade 82) were grades for this website for these instruments respectively. It showed that the quality of Persian websites according to Silberg, DISCERN and WQET instruments was "low", "more than half" and "very good" respectively. Not assigning date of entering data, author names, and references of information (authority) were most important missing characteristics of these websites. In addition, lack of interactive opportunities like chat rooms was another problem that leads to dissatisfaction of users.

  4. Preventive maintenance instrumentation results in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Palomo Anaya, M. Jose; Verdu Martin, Gumersindo; Arnaldos Gonzalvez, Adoracion; Nieva, Marcelino Curiel

    2011-01-01

    This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)

  5. Preventive maintenance instrumentation results in Spanish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Palomo Anaya, M. Jose; Verdu Martin, Gumersindo, E-mail: mpalomo@iqn.upv.es, E-mail: gverdu@iqn.upv.es [ISIRYM Universidad Politecnica de Valencia, Valencia (Spain); Arnaldos Gonzalvez, Adoracion, E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Tecnologicos SL, Valencia (Spain); Nieva, Marcelino Curiel, E-mail: m.curiel@lainsa.com [Logistica y Acondicionamientos Industriales SAU (LAINSA), Valencia (Spain)

    2011-07-01

    This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)

  6. Survey of instruments for micrometeorology

    National Research Council Canada - National Science Library

    Monteith, John Lennox

    1972-01-01

    ... have been developed for micrometeorological measurements. Many of these instruments can be used by ecologists to measure and define the environment of plants and animals and to explore the ways in which organisms modify the environment they are exposed...

  7. Programmatic Variation in Home Hemodialysis in Canada: Results from a Nationwide Survey of Practice Patterns

    Directory of Open Access Journals (Sweden)

    Robert P Pauly

    2014-06-01

    Full Text Available Background: Over 40% of patients with end stage renal disease in the United States were treated with home hemodialysis (HHD in the early 1970's. However, this number declined rapidly over the ensuing decades so that the overwhelming majority of patients were treated in-centre 3 times per week on a 3–4 hour schedule. Poor outcomes for patients treated in this fashion led to a renewed interest in home hemodialysis, with more intensive dialysis schedules including short daily (SDHD and nocturnal (NHD. The relative infancy of these treatment schedules means that there is a paucity of data on ‘how to do it’. Objective: We undertook a systematic survey of home hemodialysis programs in Canada to describe current practice patterns. Design: Development and deployment of a qualitative survey instrument. Setting: Community and academic HHD programs in Canada. Participants: Physicians, nurses and technologists. Measurements: Programmatic approaches to patient selection, delivery of dialysis, human resources available, and follow up. Methods: We developed the survey instrument in three phases. A focus group of Canadian nephrologists with expertise in NHD or SDHD discussed the scope the study and wrote questions on 11 domains. Three nephrologists familiar with all aspects of HHD delivery reviewed this for content validity, followed by further feedback from the whole group. Multidisciplinary teams at three sites pretested the survey and further suggestions were incorporated. In July 2010 we distributed the survey electronically to all renal programs known to offer HHD according to the Canadian Organ Replacement Registry. We compiled the survey results using qualitative and quantitative methods, as appropriate. Results: Of the academic and community programs that were invited to participate, 80% and 63%, respectively, completed the survey. We observed wide variation in programmatic approaches to patient recruitment, human resources, equipment, water

  8. Process Skill Assessment Instrument: Innovation to measure student’s learning result holistically

    Science.gov (United States)

    Azizah, K. N.; Ibrahim, M.; Widodo, W.

    2018-01-01

    Science process skills (SPS) are very important skills for students. However, the fact that SPS is not being main concern in the primary school learning is undeniable. This research aimed to develop a valid, practical, and effective assessment instrument to measure student’s SPS. Assessment instruments comprise of worksheet and test. This development research used one group pre-test post-test design. Data were obtained with validation, observation, and test method to investigate validity, practicality, and the effectivenss of the instruments. Results showed that the validity of assessment instruments is very valid, the reliability is categorized as reliable, student SPS activities have a high percentage, and there is significant improvement on student’s SPS score. It can be concluded that assessment instruments of SPS are valid, practical, and effective to be used to measure student’s SPS result.

  9. Dental Management Survey Brazil (DMS-BR): creation and validation of a management instrument

    Science.gov (United States)

    Gonzales, Paola Sampaio; Martins, Ismar Eduardo; Biazevic, Maria Gabriela Haye; Silva, Paulo Roberto da; Michel-Crosato, Edgard

    2017-04-10

    Questionnaires for the assessment of knowledge and self-perception can be useful to diagnose what a dentist knows about management and administration. The aim of the present study was to create and validate the Dental Management Survey Brazil (DMS-BR) scale, based on meetings with experts in the field. After having elaborated the first version, 10 audits were performed in dental offices in order to produce the final version, which included nine dimensions: location, patient, finance, marketing, competition, quality, staff, career, and productivity. The accuracy of the instrument was measured by intrarater and interrater reliability. In the validation phase, 247 Brazilian dentists answered a web-based questionnaire. The data were processed using Stata 13.0 and the significance level was set at 95%. The instrument had intrarater and interrater reliability (ICC-0.93 and 0.94). The overall average of respondents for the DMS-BR scale was 3.77 (SD = 0.45). Skewness and kurtosis were below absolute values 3 and 7, respectively. Internal validity measured by Cronbach's alpha was 0.925 and the correlation of each dimension with the final result of the DMS-BR ranged between 0.606 and 0.810. Correlation with the job satisfaction scale was 0.661. The SEM data ranged between 0.80 and 0.56. The questionnaire presented satisfactory indicators of dentists' self-perception about management and administration activities.

  10. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  11. Automated testing of health physics instruments

    International Nuclear Information System (INIS)

    Swinth, K.L.; Endres, A.W.; Hadley, R.T.; Kenoyer, J.L.

    1983-12-01

    A microcomputer controlled CAMAC system has been adapted for automated testing of health physics survey instruments. Once the survey instrument is positioned, the system automatically performs tests for angular dependence or battery lifetime. Rotation of the instrument is performed by a computer controlled stepping motor while readout is performed by an auto ranging digital volt meter and data stored on computer disks

  12. ESR teleradiology survey: results.

    Science.gov (United States)

    2016-08-01

    With recent developments of teleradiology technology and services, it has become necessary to better evaluate its extent and use among different countries in Europe. With this goal in mind, the ESR launched two specific surveys intended to gather the current state of adoption and implementation of teleradiology in clinical practice. A special focus on differentiating between insourcing teleradiology services among partners of the same organisation and outsourcing to external services was an essential part of the design of these surveys. The first survey was addressed to 44 national societies of different countries in Europe, while the second survey was intended for all practicing radiologist ESR members. While the results of these surveys reported here may provide a wealth of information to better understand the trends in adoption of teleradiology in Europe, they only represent a snapshot at a certain point in time. The rapid development of telecommunication tools as well as a fundamental change in practice and healthcare economics will certainly influence these observations in the upcoming years. These data, however, will provide objective and relevant parameters for supporting the efforts of experts and policy makers in promoting appropriate criteria and guidelines for adequate use of teleradiology in clinical practice. Main Messages • Understand concepts and challenges of teleradiology • Provide insight into current trends and solutions for teleradiology • Compare differences in teleradiolgy strategies between countries in Europe • Establish a reference on statistical data of usage of teleradiology in Europe.

  13. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  14. Upward Transfer in STEM Fields of Study: A New Conceptual Framework and Survey Instrument for Institutional Research

    Science.gov (United States)

    Wang, Xueli

    2016-01-01

    This chapter describes a new conceptual framework that informs research on factors influencing transfer in STEM fields of study from 2-year to 4-year institutions, presents a new survey instrument based on the framework, and offers directions for future research in this area.

  15. A frailty instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE).

    LENUS (Irish Health Repository)

    Romero-Ortuno, Roman

    2010-01-01

    A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http:\\/\\/www.share-project.org), a large population-based survey conducted in 2004-2005 in twelve European countries.

  16. Sexual harassment of students - survey results

    Directory of Open Access Journals (Sweden)

    Dimitrijević Aleksandra

    2017-01-01

    Full Text Available This paper aims to present results of the survey on sexual harassment of students of the Faculty of Special Education and Rehabilitation, University of Belgrade. It starts with presenting and discussing different definitions of the term ‘sexual harassment’. Afterwards, a brief overview of available surveys on this subject is provided. Results of the surveys completed so far show that this kind of students’ victimization in educational institutions is frequent in all parts of the world, regardless of the economic, ethnic and religious grounds. The aim of the survey conducted at the Faculty of Special Education and Rehabilitation (FASPER was to identify the prevalence and characteristics of sexual harassment among undergraduate students, as well as possible forms of assistance and support to students who experience sexual harassment. A survey was conducted by the students of FASPER during April and May 2014 on a sample of 147 students of all four years of undergraduate studies. For data collection a victimization survey was used. The survey results suggested that sexual harassment of students of FASPER is prevalent, while it only manifests itself in a form of verbal harassment with a sexual connotation. Female students are more exposed to harassment than male students, but we need to interpret this finding with a caution due to the fact that a sample was mostly consisted of female respondents. According to the students’ opinion, possible solutions for preventing and eliminating sexual harassment of students of FASPER are education of students and employees, adoption of rules for protection of students from this kind of victimization and establishment of support service for students who experience victimization by sexual harassment.

  17. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    Science.gov (United States)

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Polarimetric survey of main-belt asteroids. IV. New results from the first epoch of the CASLEO survey

    Science.gov (United States)

    Gil-Hutton, R.; Cellino, A.; Bendjoya, Ph.

    2014-09-01

    Aims: We present results of a polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (CASLEO), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids that belong to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties. Methods: The data were obtained using the Torino and CASPROF polarimeters at the 2.15m telescope. The Torino polarimeter is an instrument that allows simultaneous measurement of polarization in five different bands, and the CASPROF polarimeter is a two-hole aperture polarimeter with rapid modulation. Results: The survey began in 1995, and until 2012 data on a large sample of asteroids were obtained. We here present and analyze the unpublished results for 129 asteroids of different taxonomic types, 56 which were polarimetrically observed for the first time. We find that the asteroids (402) Chloe and (729) Watsonia are Barbarians, and asteroid (269) Justitia shows a phase - polarization curve that seems to have a small inversion angle. Data obtained in UBVRI colors allow us to sketch an analysis of the wavelength dependence of the degree of linear polarization for 31 asteroids, in spite of some large error bars in some cases. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.Table 1 is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/569/A122

  19. INSTRUMENTATION FOR ENVIRONMENTAL MONITORING--Radiation--Vol3Pt1

    Energy Technology Data Exchange (ETDEWEB)

    Authors, Various

    1972-01-02

    A comprehensive survey of instrumentation for environmental monitoring is being carried out by the Lawrence Berkeley Laboratory originally under a grant from the National Science Foundation and now by the Office of Health and Environmental Research of the Department of Energy. Instruments being investigated are those useful for measurements in Air Quality, Water Quality, Radiation, and Biomedicine related to environmental research and monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to this work. The results of the survey are given as (a) descriptions of the physical and operating characteristics of available instruments, (b) critical comparisons among instrumentation methods, and (c) recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored: their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls.

  20. Developing a survey instrument to assess the readiness of primary care data, genetic and disease registries to conduct linked research: TRANSFoRm International Research Readiness (TIRRE survey instrument

    Directory of Open Access Journals (Sweden)

    Emily Leppenwell

    2013-05-01

    Full Text Available Background Clinical data are collected for routine care in family practice; there are also a growing number of genetic and cancer registry data repositories. The Translational Research and Patient Safety in Europe (TRANSFoRm project seeks to facilitate research using linked data from more than one source. We performed a requirements analysis which identified a wide range of data and business process requirements that need to be met before linking primary care and either genetic or disease registry data.Objectives To develop a survey to assess the readiness of data repositories to participate in linked research – the Transform International Research Readiness (TIRRE survey.Method We develop the questionnaire based on our requirement analysis; with questions at micro-, meso- and macro levels of granularity, study-specific questions about diabetes and gastro-oesophageal reflux disease (GORD, and research track record. The scope of the data required was extensive. We piloted this instrument, conducting ten preliminary telephone interviews to evaluate the response to the questionnaire.Results Using feedback gained from these interviews we revised the questionnaire; clarifying questions that were difficult to answer and utilising skip logic to create different series of questions for the various types of data repository. We simplified the questionnaire replacing free-text responses with yes/no or picking list options, wherever possible. We placed the final questionnaire online and encouraged its use (www.clininf.eu/jointirre/info.html.Conclusion Limited field testing suggests that TIRRE is capable of collecting comprehensive and relevant data about the suitability and readiness of data repositories to participate in linked data research.

  1. Management Values Survey Results.

    Science.gov (United States)

    Duffy, Barbara; Payne, Ron

    1988-01-01

    Describes results of a survey conducted to compare values of members of the Association for Educational Communications and Technology (AECT) with managers in business and industry. Issues discussed include job satisfaction, opportunities for advancement, attitudes toward management, and salary; a summary of each value system is provided. (LRW)

  2. Organizational Member Involvement in Physical Activity Coalitions across the United States: Development and Testing of a Novel Survey Instrument for Assessing Coalition Functioning

    Science.gov (United States)

    Bornstein, Daniel B.; Pate, Russell R.; Beets, Michael W.; Saunders, Ruth P.; Blair, Steven N.

    2015-01-01

    Introduction: Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement…

  3. Measuring children's self-reported sport participation, risk perception and injury history: development and validation of a survey instrument.

    Science.gov (United States)

    Siesmaa, Emma J; Blitvich, Jennifer D; White, Peta E; Finch, Caroline F

    2011-01-01

    Despite the health benefits associated with children's sport participation, the occurrence of injury in this context is common. The extent to which sport injuries impact children's ongoing involvement in sport is largely unknown. Surveys have been shown to be useful for collecting children's injury and sport participation data; however, there are currently no published instruments which investigate the impact of injury on children's sport participation. This study describes the processes undertaken to assess the validity of two survey instruments for collecting self-reported information about child cricket and netball related participation, injury history and injury risk perceptions, as well as the reliability of the cricket-specific version. Face and content validity were assessed through expert feedback from primary and secondary level teachers and from representatives of peak sporting bodies for cricket and netball. Test-retest reliability was measured using a sample of 59 child cricketers who completed the survey on two occasions, 3-4 weeks apart. Based on expert feedback relating to face and content validity, modification and/or deletion of some survey items was undertaken. Survey items with low test-retest reliability (κ≤0.40) were modified or deleted, items with moderate reliability (κ=0.41-0.60) were modified slightly and items with higher reliability (κ≥0.61) were retained, with some undergoing minor modifications. This is the first survey of its kind which has been successfully administered to cricketers aged 10-16 years to collect information about injury risk perceptions and intentions for continued sport participation. Implications for its generalisation to other child sport participants are discussed. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  4. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  5. New results from air pollution studies in Bulgaria (moss survey 2000-2001)

    International Nuclear Information System (INIS)

    Stamenov, J.; Jovchev, M.; Vachev, B.

    2002-01-01

    New results of moss survey 2000 of systematic study of air pollution with heavy metals and other toxic elements in Bulgaria are reported. The moss samples collected at 103 sites in Bulgaria, along the borders with Yugoslavia, Macedonia, Greece and Turkey were analyzed by instrumental activation analysis using epithermal neutrons (ENAA) at the IBR-2 pulsed fast reactor for a wide set of elements including heavy metals and rare earth elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, I, Cs, Ba, La, Sm, Tb, Yb, Hf, Ta, W, Au, Th, and U). The results obtained are consistent with the mean European values for most of elements. The principle component analysis is applied to distinguish heavy and light crust elements and vegetation ones from those of anthropogenic origin

  6. New Results from Air Pollution Studies in Bulgaria (Moss Survey 2000-2001)

    CERN Document Server

    Stamenov, J N; Vachev, B; Gueleva, E; Yurukova, L; Ganeva, A; Mitrikov, M; Antonov, A; Srentz, A; Varbanov, Z; Batov, I V; Damov, K; Marinova, E; Frontasyeva, M V; Pavlov, S S; Strelkova, L P

    2002-01-01

    New results of moss survey 2000 of systematic study of air pollution with heavy metals and other toxic elements in Bulgaria are reported. The moss samples collected at 103 sites in Bulgaria, along the borders with Yugoslavia, Macedonia, Greece and Turkey were analyzed by instrumental activation analysis using epithermal neutrons (ENAA) at the IBR-2 pulsed fast reactor for a wide set of elements including heavy metals and rare earth elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, I, Cs, Ba, La, Sm, Tb, Yb, Hf, Ta, W, Au, Th, and U). The results obtained are consistent with the mean European values for most of elements. The principle component analysis is applied to distinguish heavy and light crust elements and vegetation ones from those of anthropogenic origin.

  7. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. II. HIPPARCOS STARS OBSERVED IN 2010 JANUARY AND JUNE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Gomez, Shamilia C.; Anderson, Lisa M.; Sherry, William H.; Howell, Steve B.; Ciardi, David R.; Van Altena, William F.

    2011-01-01

    The results of 497 speckle observations of Hipparcos stars and selected other targets are presented. Of these, 367 were resolved into components and 130 were unresolved. The data were obtained using the Differential Speckle Survey Instrument at the WIYN 3.5 m Telescope. (The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories.) Since the first paper in this series, the instrument has been upgraded so that it now uses two electron-multiplying CCD cameras. The measurement precision obtained when comparing to ephemeris positions of binaries with very well known orbits is approximately 1-2 mas in separation and better than 0. 0 6 in position angle. Differential photometry is found to be in very good agreement with Hipparcos measures in cases where the comparison is most relevant. We derive preliminary orbits for two systems.

  8. High School and Beyond. 1980 Senior Coort. Third-Follow-Up (1986). Data File User's Manual. Volume II: Survey Instruments. Contractor Report.

    Science.gov (United States)

    Sebring, Penny; And Others

    Survey instruments used in the collection of data for the High School and Beyond base year (1980) through the third follow-up surveys (1986) are provided as Volume II of a user's manual for the senior cohort data file. The complete user's manual is designed to provide the extensive documentation necessary for using the cohort data files. Copies of…

  9. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review

    Science.gov (United States)

    2018-01-11

    Background: This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. Methods: A systematic review study design wa...

  10. Planck 2015 results: II. Low Frequency Instrument data processings

    DEFF Research Database (Denmark)

    Ade, P. A R; Aghanim, N.; Ashdown, M.

    2016-01-01

    We present an updated description of the Planck Low Frequency Instrument (LFI) data processing pipeline, associated with the 2015 data release. We point out the places where our results and methods have remained unchanged since the 2013 paper and we highlight the changes made for the 2015 release...

  11. Planck 2013 results. VI. High Frequency Instrument data processing

    CERN Document Server

    Ade, P.A.R.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J. -P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J.J.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bowyer, J.W.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J. -F.; Catalano, A.; Chamballu, A.; Chary, R. -R.; Chen, X.; Chiang, L. -Y; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J. -M.; Désert, F. -X.; Dickinson, C.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Enßlin, T.A.; Eriksen, H.K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Girard, D.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Herent, O.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, T.R.; Jaffe, A.H.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J. -M.; Lasenby, A.; Laureijs, R.J.; Lawrence, C.R.; Jeune, M. Le; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; MacTavish, C.J.; Maffei, B.; Mandolesi, N.; Maris, M.; Marshall, D.J.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Matthai, F.; Mazzotta, P.; McGehee, P.; Meinhold, P.R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M. -A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Mottet, S.; Munshi, D.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; North, C.; Noviello, F.; Novikov, D.; Novikov, I.; Orieux, F.; Osborne, S.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paladini, R.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J. -L.; Rachen, J.P.; Racine, B.; Reach, W.T.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sanselme, L.; Santos, D.; Sauvé, A.; Savini, G.; Shellard, E.P.S.; Spencer, L.D.; Starck, J. -L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A. -S.; Sygnet, J. -F.; Tauber, J.A.; Tavagnacco, D.; Techene, S.; Terenzi, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.A.; Wandelt, B.D.; White, S.D.M.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857 GHz with an angular resolution ranging from 9.7 to 4.6 arcmin. The detector noise per (effective) beam solid angle is respectively, 10, 6, 12 and 39 microKelvin in HFI four lowest frequency channel (100--353 GHz) and 13 and 14 kJy/sr for the 545 and 857 GHz channels. Using the 143 GHz channel as a reference, these two high frequency channels are intercalibrated within 5% and the 353 GHz relative calibration is at the percent level. The 100 and 217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 < l <2500), are intercalibrated at better than 0.2 %.

  12. Report of the Survey on the Design Review of New Reactor Applications. Volume 1 - Instrumentation and Control

    International Nuclear Information System (INIS)

    Downey, Steven

    2014-06-01

    At the tenth meeting of the CNRA Working Group on the Regulation of New Reactors (WGRNR) in March 2013, the members agreed to present the responses to the Second Phase, or Design Phase, of the Licensing Process Survey as a multi-volume text. As such, each report will focus on one of the eleven general technical categories covered in the survey. The general technical categories were selected to conform to the topics covered in the International Atomic Energy Agency (IAEA) Safety Guide GS-G-4.1. This report, which is the first volume, provides a discussion of the survey responses related to Instrumentation and Control (I and C). The Instrumentation and Control category includes the twelve following technical topics: Reactor trip system, actuation systems for Engineered Safety Features (ESF), safe shutdown system, safety-related display instrumentation, information and interlock systems important to safety, controls systems, main control room, supplementary control room, diverse I and C systems, data communication systems, software reliability and cyber-security. For each technical topic, the member countries described the information provided by the applicant, the scope and level of detail of the technical review, the technical basis for granting regulatory authorisation, the skill sets required and the Level of effort needed to perform the review. Based on a comparison of the information provided in response to the survey, the following observations were made: - Among the regulatory organisations that responded to the survey, there are similarities in the design information provided by an applicant. In most countries, the design information provided by an applicant includes, but is not limited to, a description of the I and C system design and functions, a description of the verification and validation programmes, and provisions for analysis, testing, and inspection of various I and C systems. - In addition to the regulations, it is a common practice for countries

  13. FILTER-INDUCED BIAS IN Lyα EMITTER SURVEYS: A COMPARISON BETWEEN STANDARD AND TUNABLE FILTERS. GRAN TELESCOPIO CANARIAS PRELIMINARY RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    De Diego, J. A.; De Leo, M. A. [Instituto de Astronomía, Universidad Nacional Autónoma de México Avenida Universidad 3000, Ciudad Universitaria, C.P. 04510, Distrito Federal (Mexico); Cepa, J.; Bongiovanni, A. [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain); Verdugo, T. [Centro de Investigaciones de Astronomía (CIDA), Apartado Postal 264, Mérida 5101-A (Venezuela, Bolivarian Republic of); Sánchez-Portal, M. [Herschel Science Centre (HSC), European Space Agency Centre (ESAC)/INSA, Villanueva de la Cañada, Madrid (Spain); González-Serrano, J. I., E-mail: jdo@astro.unam.mx [Instituto de Física de Cantabria (CSIC-Universidad de Cantabria), E-39005 Santander (Spain)

    2013-10-01

    Lyα emitter (LAE) surveys have successfully used the excess in a narrowband filter compared to a nearby broadband image to find candidates. However, the odd spectral energy distribution (SED) of LAEs combined with the instrumental profile has important effects on the properties of the candidate samples extracted from these surveys. We investigate the effect of the bandpass width and the transmission profile of the narrowband filters used for extracting LAE candidates at redshifts z ≅ 6.5 through Monte Carlo simulations, and we present pilot observations to test the performance of tunable filters to find LAEs and other emission-line candidates. We compare the samples obtained using a narrow ideal rectangular filter, the Subaru NB921 narrowband filter, and sweeping across a wavelength range using the ultra-narrow-band tunable filters of the instrument OSIRIS, installed at the 10.4 m Gran Telescopio Canarias. We use this instrument for extracting LAE candidates from a small set of real observations. Broadband data from the Subaru, Hubble Space Telescope, and Spitzer databases were used for fitting SEDs to calculate photometric redshifts and to identify interlopers. Narrowband surveys are very efficient in finding LAEs in large sky areas, but the samples obtained are not evenly distributed in redshift along the filter bandpass, and the number of LAEs with equivalent widths <60 Å can be underestimated. These biased results do not appear in samples obtained using ultra-narrow-band tunable filters. However, the field size of tunable filters is restricted because of the variation of the effective wavelength across the image. Thus, narrowband and ultra-narrow-band surveys are complementary strategies to investigate high-redshift LAEs.

  14. FILTER-INDUCED BIAS IN Lyα EMITTER SURVEYS: A COMPARISON BETWEEN STANDARD AND TUNABLE FILTERS. GRAN TELESCOPIO CANARIAS PRELIMINARY RESULTS

    International Nuclear Information System (INIS)

    De Diego, J. A.; De Leo, M. A.; Cepa, J.; Bongiovanni, A.; Verdugo, T.; Sánchez-Portal, M.; González-Serrano, J. I.

    2013-01-01

    Lyα emitter (LAE) surveys have successfully used the excess in a narrowband filter compared to a nearby broadband image to find candidates. However, the odd spectral energy distribution (SED) of LAEs combined with the instrumental profile has important effects on the properties of the candidate samples extracted from these surveys. We investigate the effect of the bandpass width and the transmission profile of the narrowband filters used for extracting LAE candidates at redshifts z ≅ 6.5 through Monte Carlo simulations, and we present pilot observations to test the performance of tunable filters to find LAEs and other emission-line candidates. We compare the samples obtained using a narrow ideal rectangular filter, the Subaru NB921 narrowband filter, and sweeping across a wavelength range using the ultra-narrow-band tunable filters of the instrument OSIRIS, installed at the 10.4 m Gran Telescopio Canarias. We use this instrument for extracting LAE candidates from a small set of real observations. Broadband data from the Subaru, Hubble Space Telescope, and Spitzer databases were used for fitting SEDs to calculate photometric redshifts and to identify interlopers. Narrowband surveys are very efficient in finding LAEs in large sky areas, but the samples obtained are not evenly distributed in redshift along the filter bandpass, and the number of LAEs with equivalent widths <60 Å can be underestimated. These biased results do not appear in samples obtained using ultra-narrow-band tunable filters. However, the field size of tunable filters is restricted because of the variation of the effective wavelength across the image. Thus, narrowband and ultra-narrow-band surveys are complementary strategies to investigate high-redshift LAEs

  15. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  16. Planck early results. VI. The High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Colley, J.-M.; Bartlett, J.G.; Bucher, M.

    2011-01-01

    We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545...... and 857 GHz with an angular resolution ranging from 9.9 to 4.4′. The white noise level is around 1.5 μK degree or less in the 3 main CMB channels (100-217 GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created...... by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy. They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears...

  17. UAVSAR Program: Initial Results from New Instrument Capabilities

    Science.gov (United States)

    Lou, Yunling; Hensley, Scott; Moghaddam, Mahta; Moller, Delwyn; Chapin, Elaine; Chau, Alexandra; Clark, Duane; Hawkins, Brian; Jones, Cathleen; Marks, Phillip; hide

    2013-01-01

    UAVSAR is an imaging radar instrument suite that serves as NASA's airborne facility instrument to acquire scientific data for Principal Investigators as well as a radar test-bed for new radar observation techniques and radar technology demonstration. Since commencing operational science observations in January 2009, the compact, reconfigurable, pod-based radar has been acquiring L-band fully polarimetric SAR (POLSAR) data with repeat-pass interferometric (RPI) observations underneath NASA Dryden's Gulfstream-III jet to provide measurements for science investigations in solid earth and cryospheric studies, vegetation mapping and land use classification, archaeological research, soil moisture mapping, geology and cold land processes. In the past year, we have made significant upgrades to add new instrument capabilities and new platform options to accommodate the increasing demand for UAVSAR to support scientific campaigns to measure subsurface soil moisture, acquire data in the polar regions, and for algorithm development, verification, and cross-calibration with other airborne/spaceborne instruments.

  18. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer surgery

    Directory of Open Access Journals (Sweden)

    Sepucha Karen R

    2012-06-01

    Full Text Available Abstract Background The purpose of this paper is to examine the acceptability, feasibility, reliability and validity of a new decision quality instrument that assesses the extent to which patients are informed and receive treatments that match their goals. Methods Cross-sectional mail survey of recent breast cancer survivors, providers and healthy controls and a retest survey of survivors. The decision quality instrument includes knowledge questions and a set of goals, and results in two scores: a breast cancer surgery knowledge score and a concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, discriminant validity, content validity, predictive validity and retest reliability of the survey instrument were examined. Results We had responses from 440 eligible patients, 88 providers and 35 healthy controls. The decision quality instrument was feasible to implement in this study, with low missing data. The knowledge score had good retest reliability (intraclass correlation coefficient = 0.70 and discriminated between providers and patients (mean difference 35%, p  Conclusions The decision quality instrument met the criteria of feasibility, reliability, discriminant and content validity in this sample. Additional research to examine performance of the instrument in prospective studies and more diverse populations is needed.

  19. The SOFIA Massive (SOMA) Star Formation Survey. I. Overview and First Results

    Energy Technology Data Exchange (ETDEWEB)

    De Buizer, James M.; Shuping, Ralph [SOFIA-USRA, NASA Ames Research Center, MS 232-12, Moffett Field, CA 94035 (United States); Liu, Mengyao; Tan, Jonathan C.; Staff, Jan E.; Tanaka, Kei E. I. [Department of Astronomy, University of Florida, Gainesville, FL 32611 (United States); Zhang, Yichen [Departamento de Astronomía, Universidad de Chile, Casilla 36-D, Santiago (Chile); Beltrán, Maria T. [INAF-Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, I-50125 Firenze (Italy); Whitney, Barbara [Department of Astronomy, University of Wisconsin-Madison, 475 N. Charter St, Madison, WI 53706 (United States)

    2017-07-01

    We present an overview and first results of the Stratospheric Observatory For Infrared Astronomy Massive (SOMA) Star Formation Survey, which is using the FORCAST instrument to image massive protostars from ∼10 to 40 μ m. These wavelengths trace thermal emission from warm dust, which in Core Accretion models mainly emerges from the inner regions of protostellar outflow cavities. Dust in dense core envelopes also imprints characteristic extinction patterns at these wavelengths, causing intensity peaks to shift along the outflow axis and profiles to become more symmetric at longer wavelengths. We present observational results for the first eight protostars in the survey, i.e., multiwavelength images, including some ancillary ground-based mid-infrared (MIR) observations and archival Spitzer and Herschel data. These images generally show extended MIR/FIR emission along directions consistent with those of known outflows and with shorter wavelength peak flux positions displaced from the protostar along the blueshifted, near-facing sides, thus confirming qualitative predictions of Core Accretion models. We then compile spectral energy distributions and use these to derive protostellar properties by fitting theoretical radiative transfer models. Zhang and Tan models, based on the Turbulent Core Model of McKee and Tan, imply the sources have protostellar masses m {sub *} ∼ 10–50 M {sub ⊙} accreting at ∼10{sup −4}–10{sup −3} M {sub ⊙} yr{sup −1} inside cores of initial masses M {sub c} ∼ 30–500 M {sub ⊙} embedded in clumps with mass surface densities Σ{sub cl} ∼ 0.1–3 g cm{sup −2}. Fitting the Robitaille et al. models typically leads to slightly higher protostellar masses, but with disk accretion rates ∼100× smaller. We discuss reasons for these differences and overall implications of these first survey results for massive star formation theories.

  20. Jovian seismology: preliminary results of the SYMPA instrument

    Science.gov (United States)

    Gaulme, P.; Schmider, F. X.; Gay, J.; Jacob, C.; Jeanneaux, F.; Alvarez, M.; Reyes, M.; Valtier, J. C.; Fossat, E.; Palle, P. L.; Belmonte, J. C.; Gelly, B.

    2006-06-01

    Jupiter's internal structure is poorly known (Guillot et al. 2004). Seismology is a powerful tool to investigate the internal structure of planets and stars, by analyzing how acoustic waves propagate. Mosser (1997) and Gudkova & Zarkhov (1999) showed that the detection and the identification of non-radial modes up to degree ℓ=25 can constrain strongly the internal structure. SYMPA is a ground-based network project dedicated to the Jovian oscillations (Schmider et al. 2002). The instrument is composed of a Mach-Zehnder interferometer producing four interferograms of the planetary spectrum. The combination of the four images in phase quadrature allows the reconstruction of the incident light phase, which is related to the Doppler shift generated by the oscillations. Two SYMPA instruments were built at the Nice university and were used simultaneously during two observation campaigns, in 2004 and 2005, at the San Pedro Martir observatory (Mexico) and the Teide observatory (Las Canarias). We will present for the first time the data processing and the preliminary results of the experiment.

  1. New instrument for measuring student beliefs about physics and learning physics: The Colorado Learning Attitudes about Science Survey

    Science.gov (United States)

    Adams, W. K.; Perkins, K. K.; Podolefsky, N. S.; Dubson, M.; Finkelstein, N. D.; Wieman, C. E.

    2006-06-01

    The Colorado Learning Attitudes about Science Survey (CLASS) is a new instrument designed to measure student beliefs about physics and about learning physics. This instrument extends previous work by probing additional aspects of student beliefs and by using wording suitable for students in a wide variety of physics courses. The CLASS has been validated using interviews, reliability studies, and extensive statistical analyses of responses from over 5000 students. In addition, a new methodology for determining useful and statistically robust categories of student beliefs has been developed. This paper serves as the foundation for an extensive study of how student beliefs impact and are impacted by their educational experiences. For example, this survey measures the following: that most teaching practices cause substantial drops in student scores; that a student’s likelihood of becoming a physics major correlates with their “Personal Interest” score; and that, for a majority of student populations, women’s scores in some categories, including “Personal Interest” and “Real World Connections,” are significantly different from men’s scores.

  2. Polarimetric survey of main-belt asteroids⋆. III. Results for 33 X-type objects

    Science.gov (United States)

    Cañada-Assandri, M.; Gil-Hutton, R.; Benavidez, P.

    2012-06-01

    Aims: We present results of a polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (Casleo), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids that belong to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties. Methods: The data were obtained with the Torino and CASPROF polarimeters at the 2.15 m telescope. The Torino polarimeter is an instrument that allows the simultaneous measurement of polarization in five different bands, and the CASPROF polarimeter is a two-hole aperture polarimeter with rapid modulation. Results: The survey began in 2003, and up to 2009 data of a sample of more than 170 asteroids were obtained. In this paper the results for 33 X-type objects are presented, several of them are being polarimetrically observed for the first time. Using these data we found polarization curves and polarimetric parameters for different groups among this taxonomic class and that there are objects with very different albedo in the sub-classes of the X taxonomic complex. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.Table 1 is only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/542/A11

  3. Summary of microsatellite instability test results from laboratories participating in proficiency surveys: proficiency survey results from 2005 to 2012.

    Science.gov (United States)

    Boyle, Theresa A; Bridge, Julia A; Sabatini, Linda M; Nowak, Jan A; Vasalos, Patricia; Jennings, Lawrence J; Halling, Kevin C

    2014-03-01

    The College of American Pathologists surveys are the largest laboratory peer comparison programs in the world. These programs allow laboratories to regularly evaluate their performance and improve the accuracy of the patient test results they provide. Proficiency testing is offered twice a year to laboratories performing microsatellite instability testing. These surveys are designed to emulate clinical practice, and some surveys have more challenging cases to encourage the refinement of laboratory practices. This report summarizes the results and trends in microsatellite instability proficiency testing from participating laboratories from the inception of the program in 2005 through 2012. We compiled and analyzed data for 16 surveys of microsatellite instability proficiency testing during 2005 to 2012. The number of laboratories participating in the microsatellite instability survey has more than doubled from 42 to 104 during the 8 years analyzed. An average of 95.4% of the laboratories correctly classified each of the survey test samples from the 2005A through 2012B proficiency challenges. In the 2011B survey, a lower percentage of laboratories (78.4%) correctly classified the specimen, possibly because of overlooking subtle changes of microsatellite instability and/or failing to enrich the tumor content of the specimen to meet the limit of detection of their assay. In general, laboratories performed well in microsatellite instability testing. This testing will continue to be important in screening patients with colorectal and other cancers for Lynch syndrome and guiding the management of patients with sporadic colorectal cancer.

  4. Gemini Planet Imager Exoplanet Survey: Key Results Two Years Into The Survey

    Science.gov (United States)

    Marchis, Franck; Rameau, Julien; Nielsen, Eric L.; De Rosa, Robert J.; Esposito, Thomas; Draper, Zachary H.; Macintosh, Bruce; Graham, James R.; GPIES

    2016-10-01

    The Gemini Planet Imager Exoplanet Survey (GPIES) is targeting 600 young, nearby stars using the GPI instrument. We report here on recent results obtained with this instrument from our team.Rameau et al. (ApJL, 822 2, L2, 2016) presented astrometric monitoring of the young exoplanet HD 95086 b obtained with GPI between 2013 and 2016. Efficient Monte Carlo techniques place preliminary constraints on the orbital parameters of HD 95086 b. Under the assumption of a coplanar planet-disk system, the periastron of HD 95086 b is beyond 51 AU. Therefore, HD 95086 b cannot carve the entire gap inferred from the measured infrared excess in the SED of HD 95086. Additional photometric and spectroscopic measurements reported by de Rosa et al. (2016, apJ, in press) showed that the spectral energy distribution of HD 95086 b is best fit by low temperature (T~800-1300 K), low surface gravity spectra from models which simulate high photospheric dust content. Its temperature is typical to L/T transition objects, but the spectral type is poorly constrained. HD 95086 b is an important exoplanet to test our models of atmospheric properties of young extrasolar planets.Direct detections of debris disk are keys to infer the collisional past and understand the formation of planetary systems. Two debris disks were recently studied with GPI:- Draper et al. (submitted to ApJ, 2016) show the resolved circumstellar debris disk around HD 111520 at a projected range of ~30-100 AU using both total and polarized H-band intensity. Structures in the disks such as a large brightness asymmetry and symmetric polarization fraction are seen. Additional data would confirm if a large disruption event from a stellar fly-by or planetary perturbations altered the disk density- Esposito et al. (submitted to ApJ, 2016) combined Keck NIRC2 data taken at 1.2-2.3 microns and GPI 1.6 micron total intensity and polarized light detections that probes down to projected separations less than 10 AU to show that the HD

  5. E-Books in Academic Libraries: Results of a Survey Carried out in Sweden and Lithuania

    Science.gov (United States)

    Maceviciute, Elena; Wilson, T. D.; Gudinavicius, Arunas; Šuminas, Andrius

    2017-01-01

    Introduction: This paper reports on a study of e-books issues in academic libraries in two European countries representative of small language markets--Sweden and Lithuania. Method: Questionnaire surveys, using the same instrument, were carried out in Swedish and Lithuanian academic libraries. Analysis: Quantitative analysis was performed using…

  6. Towards an Enterprise Architecture Benefits Measurement Instrument

    NARCIS (Netherlands)

    Dr.ir. Raymond Slot; Henk Plessius; Marlies Steenbergen, van

    2015-01-01

    Author supplied: Based on the Enterprise Architecture Value Framework (EAVF) - a generic framework to classify benefits of Enterprise Architecture (EA) - a measurement instrument for EA benefits has been developed and tested in a survey with 287 respondents. In this paper we present the results of

  7. Statistical literacy and sample survey results

    Science.gov (United States)

    McAlevey, Lynn; Sullivan, Charles

    2010-10-01

    Sample surveys are widely used in the social sciences and business. The news media almost daily quote from them, yet they are widely misused. Using students with prior managerial experience embarking on an MBA course, we show that common sample survey results are misunderstood even by those managers who have previously done a statistics course. In general, they fare no better than managers who have never studied statistics. There are implications for teaching, especially in business schools, as well as for consulting.

  8. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  9. Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

    Science.gov (United States)

    Baldwin, H. A.

    1972-01-01

    Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

  10. WFIRST: Data/Instrument Simulation Support at IPAC

    Science.gov (United States)

    Laine, Seppo; Akeson, Rachel; Armus, Lee; Bennett, Lee; Colbert, James; Helou, George; Kirkpatrick, J. Davy; Meshkat, Tiffany; Paladini, Roberta; Ramirez, Solange; Wang, Yun; Xie, Joan; Yan, Lin

    2018-01-01

    As part of WFIRST Science Center preparations, the IPAC Science Operations Center (ISOC) maintains a repository of 1) WFIRST data and instrument simulations, 2) tools to facilitate scientific performance and feasibility studies using the WFIRST, and 3) parameters summarizing the current design and predicted performance of the WFIRST telescope and instruments. The simulation repository provides access for the science community to simulation code, tools, and resulting analyses. Examples of simulation code with ISOC-built web-based interfaces include EXOSIMS (for estimating exoplanet yields in CGI surveys) and the Galaxy Survey Exposure Time Calculator. In the future the repository will provide an interface for users to run custom simulations of a wide range of coronagraph instrument (CGI) observations and sophisticated tools for designing microlensing experiments. We encourage those who are generating simulations or writing tools for exoplanet observations with WFIRST to contact the ISOC team so we can work with you to bring these to the attention of the broader astronomical community as we prepare for the exciting science that will be enabled by WFIRST.

  11. NREL Partnership Survey - FY 2016 Results

    Energy Technology Data Exchange (ETDEWEB)

    2016-09-01

    The National Renewable Energy Laboratory (NREL) conducts an annual partnership satisfaction survey in which we ask our clients to rate NREL in a number of areas. As a national laboratory, the principal areas we focus on include value, timeliness, quality, price, and capabilities. This fact sheet shows the results of a survey with 300 customers responding to 11 questions using ratings that vary from 'strongly agree' to 'strongly disagree.' In FY 16, 100% of the scores improved or were equal to FY 15 numbers.

  12. Long-term results using LigaSure™ 5 mm instrument for treatment of Zenker's diverticulum

    DEFF Research Database (Denmark)

    Andersen, Michelle Fog; Trolle, Waldemar; Anthonsen, Kristian

    2017-01-01

    The purpose of the present study was to evaluate the long-term results and patient's satisfaction of a new approach using the LigaSure™ 5 mm instrument for treatment of Zenker's diverticulum (ZD) and to compare with other long-term results using traditional treatment modalities. Between December ...... to traditional endoscopic techniques and is now the standard treatment method for ZD in our departments.......The purpose of the present study was to evaluate the long-term results and patient's satisfaction of a new approach using the LigaSure™ 5 mm instrument for treatment of Zenker's diverticulum (ZD) and to compare with other long-term results using traditional treatment modalities. Between December......%) reported no symptoms at all. Our results suggest that endoscopic management of ZD with the LigaSure™ 5 mm instrument is a minimally invasive, fast and safe method with solid long-term outcome with relief of symptoms and patient satisfaction. This new operative instrument was not found inferior...

  13. First Results from the Dense Extragalactic GBT+ARGUS Survey (DEGAS): A Direct, Quantitative Test of the Role of Gas Density in Star Formation

    Science.gov (United States)

    Kepley, Amanda; Bigiel, Frank; Bolatto, Alberto; Church, Sarah; Cleary, Kieran; Frayer, David; Gallagher, Molly; Gundersen, Joshua; Harris, Andrew; Hughes, Annie; Jimenez-Donaire, Maria Jesus; Kessler, Sarah; Lee, Cheoljong; Leroy, Adam; Li, Jialu; Donovan Meyer, Jennifer; Rosolowsky, Erik; Sandstrom, Karin; Schinnener, Eva; Schruba, Andreas; Sieth, Matt; Usero, Antonio

    2018-01-01

    Gas density plays a central role in all modern theories of star formation. A key test of these theories involves quantifying the resolved gas density distribution and its relationship to star formation within a wide range of galactic environments. Until recently, this experiment has been difficult to perform owing to the faint nature of key molecular gas tracers like HCN and HCO+, but the superior sensitivity of modern millimeter instruments like ALMA and the IRAM 30m make these types of experiments feasible. In particular, the sensitivity and resolution provided by large aperture of the GBT combined with fast mapping speeds made possible by its new 16-pixel, 3mm focal plane array (Argus) make the GBT an almost-ideal instrument for this type of study. The Dense Extragalactic GBT+Argus Survey (DEGAS) will leverage these capabilities to perform the largest, resolved survey of molecular gas tracers in nearby galaxies, ultimately mapping a suite of four molecular gas tracers in the inner 2’ by 2’ of 36 nearby galaxies. When complete in 2020, DEGAS will be the largest resolved survey of dense molecular gas tracers in nearby galaxies. This talk will present early results from the first observations for this Green Bank Telescope large survey and highlight some exciting future possibilities for this survey.

  14. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    Science.gov (United States)

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  15. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    Science.gov (United States)

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  16. Automated extinction monitor for the NLOT site survey

    Science.gov (United States)

    Kumar Sharma, Tarun

    In order to search a few potential sites for the National Large Optical Telescope (NLOT) project, we have initiated a site survey program. Since, most of instruments used for the site survey are custom made, we also started developing our own site characterization instruments. In this process we have designed and developed a device called Automated Extinction Monitor (AEM) and installed the same at IAO, Hanle. The AEM is a small wide field robotic telescope, dedicated to record atmospheric extinction in one or more photometric bands. It gives very accurate statistics of the distribution of photometric nights. In addition to this, instrument also provides the measurement of sky brightness. Here we briefly describe overall instrument and initial results obtained.

  17. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  18. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  19. Cotrel-dubousset instrumentation for the correction of adolescent idiopathic scoliosis. Long-term results with an unexpected high revision rate

    Directory of Open Access Journals (Sweden)

    Mueller Franz J

    2012-06-01

    Full Text Available Abstract Background For many years, the CD instrumentation has been regarded as the standard device for the surgical correction of adolescent idiopathic scoliosis (AIS. Nevertheless, scientific long-term results on this procedure are rare. Therefore, we conducted a retrospective follow-up study of patients treated for AIS with CD instrumentation and spondylodesis. Methods A total of 40 patients with AIS underwent CD instrumentation in our department within 3 years and between 1990 and 1992. For the retrospective analysis, first all the patient documents were reviewed, and pre-/postoperative X-ray images as well as those at the latest follow-up were analysed. Furthermore, it was attempted to conduct a clinical survey using the SRS-24 questionnaire, which was sent to the patients after a preceding announcement on the phone. Results Radiologically, the frontal main curvature was improved from a preoperative angle of 69.2° to a postoperative angle of 35.4°, and the secondary curvature was improved from a preoperative angle of 42.6° to a postoperative angle of 20.5°. The latest radiological follow-up at average 57.4 months post surgery showed an average loss of correction of 9.6° (main curvature and 4.6° (secondary curvature, respectively. Within the first 30 days post surgery, 3 out of 40 patients (7.5% received early operative revision for the dislocation of hooks or rods. At an average of 45.7 months (range 11 to 142 months, 19 out of 40 patients (47.5%; including 2 patients with early revision received late operative revisions: The reasons were late infection (10 out of 40 patients; 25% with the development of fistulae (7 cases or putrid secretion (3 cases, which was resolved with the complete removal of instrumentation after all. The average time until revision was 35.5 months (range 14 to 56 months after CD instrumentation. Furthermore, complete implant removal was necessary in 8 out of 40 patients (20% for late operate site

  20. Swift Burst Alert Telescope (BAT) Instrument Response

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Hullinger, D.; Krimm, H.; Markwardt, C.; Tueller, J.; Fenimore, E.; Palmer, D.; Sato, G.; Takahashi, T.; Nakazawa, K.; Okada, Y.; Takahashi, H.; Suzuki, M.; Tashiro, M.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts, and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. This paper describes the spectral models and the ground calibration experiments used to determine the BAT response to an accuracy suitable for gamma-ray burst studies

  1. Psychometric Analysis and Qualitative Review of an Outpatient Radiology-Specific Patient Satisfaction Survey: A Call for Collaboration in Validating a Survey Instrument.

    Science.gov (United States)

    Dibble, Elizabeth H; Baird, Grayson L; Swenson, David W; Healey, Terrance T

    2017-10-01

    The aim of this study was to perform a psychometric analysis of the constructs and reliability of an outpatient radiology-specific patient satisfaction survey and identify factors that drive patient experience so that radiology practices can improve the quality of their diagnostic imaging services. This retrospective study examined responses to eight patient satisfaction questions from a survey originally developed by a nascent marketing team and then administered at five outpatient imaging centers from January 7, 2013, to November 11, 2015. Patients' responses were reviewed to identify factors that affected patient experience, and a psychometric analysis of the survey instrument itself was performed, including exploratory factor analyses and reliability testing. Patient responses were compared among sites, examination types, and questions. Free-text comments were qualitatively categorized and compared by examination type. In total, 6,512 surveys were completed among 137,059 patient encounters. Using exploratory factor analyses of the eight survey questions, three relevant patient experience constructs were derived: (1) front office experience, (2) intake experience, and (3) examination experience. Overall, good scale reliability was observed. Perceived quality of care had the most positive ratings; wait time had the most nonpositive ratings. Of 2,024 free-text comments, 1,859 were positive (most pertaining to staff), and 155 were negative (most pertaining to convenience). MRI patients were most likely to share negative comments, typically regarding the examination experience itself. Psychometric analysis of a patient survey derived three core patient experience constructs: front office experience, intake experience, and examination experience. The survey indicates the need to decrease wait times, streamline the registration process, and improve patient comfort during MRI examinations. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All

  2. Principles of survey development for telemedicine applications.

    Science.gov (United States)

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  3. Polarimetric survey of main-belt asteroids. II. Results for 58 B- and C-type objects

    Science.gov (United States)

    Gil-Hutton, R.; Cañada-Assandri, M.

    2012-03-01

    Aims: We present results of a polarimetric survey of main-belt asteroids at Complejo Astronómico el Leoncito (CASLEO), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids that belong to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties. Methods: The data were obtained with the Torino and CASPROF polarimeters at the 2.15m telescope. The Torino polarimeter is an instrument that allows simultaneous measurement of polarization in five different bands, and the CASPROF polarimeter is a two-hole aperture polarimeter with rapid modulation. Results: The survey began in 2003, and up to 2009 data on a sample of more than 170 asteroids were obtained. In this paper the results for 58 B- and C-type objects are presented, most of them polarimetrically observed for the first time. Using these data we find phase-polarization curves and polarimetric parameters for these taxonomic classes. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.Tables 1 and 2 are available in electronic form at CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/539/A115

  4. Design of and initial results from a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC

    Directory of Open Access Journals (Sweden)

    D. R. Glowacki

    2007-10-01

    Full Text Available The design of a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC is described and initial results obtained from HIRAC are presented. The ability of HIRAC to perform in-situ laser-induced fluorescence detection of OH and HO2 radicals with the Fluorescence Assay by Gas Expansion (FAGE technique establishes it as internationally unique for a chamber of its size and pressure/temperature variable capabilities. In addition to the FAGE technique, HIRAC features a suite of analytical instrumentation, including: a multipass FTIR system; a conventional gas chromatography (GC instrument and a GC instrument for formaldehyde detection; NO/NO2, CO, O3, and H2O vapour analysers. Ray tracing simulations and NO2 actinometry have been utilized to develop a detailed model of the radiation field within HIRAC. Comparisons between the analysers and the FTIR coupled to HIRAC have been performed, and HIRAC has also been used to investigate pressure dependent kinetics of the chlorine atom reaction with ethene and the reaction of O3 and t-2-butene. The results obtained are in good agreement with literature recommendations and Master Chemical Mechanism predictions. HIRAC thereby offers a highly instrumented platform with the potential for: (1 high precision kinetics investigations over a range of atmospheric conditions; (2 detailed mechanism development, significantly enhanced according to its capability for measuring radicals; and (3 field instrument intercomparison, calibration, development, and investigations of instrument response at a range of atmospheric conditions.

  5. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    International Nuclear Information System (INIS)

    Lucon, E.

    2008-01-01

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  6. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-09-15

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  7. Further assessment of survey results from the beaches around Sellafield

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Fry, F.A.

    1984-02-01

    Contaminated material continues to be found on the beaches, estuaries and salt marshes. An initial apparent fall in the frequency of discovery of highly contaminated samples has not been sustained. In the last week of surveys reported here, a change was noted in the type of contaminated material found. Results averaged on the entire period from 19 November 1983 to 13 February 1984 suggest that about 2 items every kilometre might be found giving a reading in excess of 1 mR/L βγ and 1 item every few kilometres giving a reading in excess of 10 mR/h βγ, with actual contact dose rates possible of about a hundred times higher than apparent instrument readings. A member of the public could pick up an item contaminated in excess of the 10 mR/h βγ or 1000 cps criterion and hold it for sufficiently long to sustain an appreciable dose to the skin surface. These and laboratory studies of contaminated materials confirmed the Board's views that the only situations of concern are those of prolonged handling of debris and contamination of the skin, rather than intake by ingestion or inhalation. (U.K.)

  8. Robotic and Survey Telescopes

    Science.gov (United States)

    Woźniak, Przemysław

    Robotic telescopes are revolutionizing the way astronomers collect their dataand conduct sky surveys. This chapter begins with a discussion of principles thatguide the process of designing, constructing, and operating telescopes andobservatories that offer a varying degree of automation, from instruments remotelycontrolled by observers to fully autonomous systems requiring no humansupervision during their normal operations. Emphasis is placed on designtrade-offs involved in building end-to-end systems intended for a wide range ofscience applications. The second part of the chapter contains descriptions ofseveral projects and instruments, both existing and currently under development.It is an attempt to provide a representative selection of actual systems thatillustrates state of the art in technology, as well as important ideas and milestonesin the development of the field. The list of presented instruments spans the fullrange in size starting from small all-sky monitors, through midrange robotic andsurvey telescopes, and finishing with large robotic instruments and surveys.Explosive growth of telescope networking is enabling entirely new modesof interaction between the survey and follow-up observing. Increasingimportance of standardized communication protocols and software is stressed.These developments are driven by the fusion of robotic telescope hardware,massive storage and databases, real-time knowledge extraction, and datacross-correlation on a global scale. The chapter concludes with examplesof major science results enabled by these new technologies and futureprospects.

  9. Personal assistance, income and employment: the spinal injuries survey instrument (SISI) and its application in a sample of people with quadriplegia.

    Science.gov (United States)

    Rowell, D; Connelly, L B

    2008-06-01

    Our aim was to ascertain what effect access to personal care package (PCP) has on the labour market activities of people who have a spinal cord injury (SCI). We developed a new instrument called the spinal injuries survey instrument (SISI). The SISI is a 35-item instrument, which contains items on health, education, employment, along with measures of personal assistance, mobility and psychological attribution style. The SISI was administered, with the Short Form 36 (SF-36) health status instrument, to 250 people with an SCI. The response rate was 72%. A retrospective, matched case-control sampling approach matched individuals who received a PCP, with a cohort who did not. The matching criteria included the site and severity of spinal lesion, age and gender. Although data on the reliability of the instrument are currently lacking, our empirical results are consistent with other studies: (1) mean annual health care costs (AUD$8741) are comparable with Walsh's estimates (2) SF-36 data support Kreuter's contention that mental health is resilient to SCI and (3) a post-injury employment rate of 29.7% corroborates Murphy et al. We present additional data describing income, educational attainment and family support. Our discussion borrows a conceptualization of disability by Sen, that includes both an 'earning handicap' (an impediment to earn income) and a 'conversion handicap' (an impediment to the enjoyment of income). Our application of the SISI provides evidence of both. The labour income of people with quadriplegia is AUD$10,007 per annum, while diminished health status, increased out-of-pocket health expenditure and loss of time suggest a conversion handicap.

  10. The Impact of Repeated Lying on Survey Results

    Directory of Open Access Journals (Sweden)

    Thomas Chesney

    2013-01-01

    Full Text Available We study the effects on results of participants completing a survey more than once, a phenomenon known as farming. Using data from a real social science study as a baseline, three strategies that participants might use to farm are studied by Monte Carlo simulation. Findings show that farming influences survey results and can cause both statistical hypotheses testing Type I (false positive and Type II (false negative errors in unpredictable ways.

  11. NEW INSTRUMENTS FOR SURVEY: ON LINE SOFTWARES FOR 3D RECONTRUCTION FROM IMAGES

    Directory of Open Access Journals (Sweden)

    E. Fratus de Balestrini

    2012-09-01

    Full Text Available 3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting, acquisition tools (digital cameras and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings

  12. "Against the silence": Development and first results of a patient survey to assess experiences of safety-related events in hospital

    Directory of Open Access Journals (Sweden)

    Schwappach David LB

    2008-03-01

    Full Text Available Abstract Background Involvement of patients in the detection and prevention of safety related events and medical errors have been widely recommended. However, it has also been questioned whether patients at large are willing and able to identify safety-related events in their care. The aim of this study was to develop and pilot test a brief patient safety survey applicable to inpatient care in Swiss hospitals. Methods A survey instrument was developed in an iterative procedure. The instrument asks patients to report whether they have experienced specific undesirable events during their hospital stay. The preliminary version was developed together with experts and tested in focus groups with patients. The adapted survey instrument was pilot-tested in random samples of patients of two Swiss hospitals (n = 400. Responders to the survey that had reported experience of any incident were sampled for qualitative interviews (n = 18. Based on the interview, the researcher classified the reported incidents as confirmed or discarded. Results The survey was generally well accepted in the focus groups and interviews. In the quantitative pilot test, 125 patients returned the survey (response rate: 31%. The mean age of responders was 55 years (range 17–91, SD 18 years and 62.5% were female. The 125 participating patients reported 94 "definitive" and 34 "uncertain" events. 14% of the patients rated any of the experienced events as "serious". The definitive and uncertain events reported with highest frequency were phlebitis, missing hand hygiene, allergic drug reaction, unavailability of documents, and infection. 23% of patients reported some or serious concerns about their safety. The qualitative interviews indicate that both, the extent of patients' uncertainty in the classification of events and the likelihood of confirmation by the interviewer vary very much by type of incident. Unexpectedly, many patients reported problems and incidents related to food

  13. Results of the first tests of the SIDRA satellite-borne instrument breadboard model

    International Nuclear Information System (INIS)

    Dudnik, O.V.; Kurbatov, E.V.; Avilov, A.M.; Titov, K.G.; Prieto, M; Sanchez, S.; Spassky, A.V.; Sylwester, J.; Gburek, S.; Podgorski, P.

    2013-01-01

    In this work, the results of the calibration of the solid-state detectors and electronic channels of the SIDRA satellite borne energetic charged particle spectrometer-telescope breadboard model are presented. The block schemes and experimental equipment used to conduct the thermal vacuum and electromagnetic compatibility tests of the assemblies and modules of the compact satellite equipment are described. The results of the measured thermal conditions of operation of the signal analog and digital processing critical modules of the SIDRA instrument prototype are discussed. Finally, the levels of conducted interference generated by the instrument model in the primary vehicle-borne power circuits are presented.

  14. Calibration of a radiation survey meter using Cs-137 gamma source

    International Nuclear Information System (INIS)

    Khalid, R. O.

    2005-07-01

    The survey instrument smartIon was calibrated at the Secondary Standard Dosimetry Laboratory, Sudan Atomic Energy Commission, in terms of kerma, free in air using Cs-137 gamma radiation. All the calibrations were performed using the reference instrument spherical ionization chamber LS-01. This reference instrument has been calibrated at the International Atomic Energy Agency, Vienna for x-rays, 137 Cs and 60 Co gamma radiation. The air kerma calibration factors for the instrument were determined as the ratio of the dose rates obtained with the reference standard chamber LS-01 and the dose rates of the instrument under calibration. The uncertainties for the survey meter smartIon and another survey meter RADOS were obtained and the results compared with the uncertainty for the reference standard chamber. Also, the values of dose rates were obtained for various angles of the incident beam, by changing the angle by which the radiation was incident on the sensitive point of the instrument.(Author)

  15. The green bank northern celestial cap pulsar survey. I. Survey description, data analysis, and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, K.; Dartez, L. P.; Ford, A. J.; Garcia, A.; Hinojosa, J.; Jenet, F. A.; Leake, S. [Center for Advanced Radio Astronomy, University of Texas at Brownsville, One West University Boulevard, Brownsville, TX 78520 (United States); Lynch, R. S.; Archibald, A. M.; Karako-Argaman, C.; Kaspi, V. M. [Department of Physics, McGill University, 3600 University Street, Montreal, QC H3A 2T8 (Canada); Ransom, S. M. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22901 (United States); Banaszak, S.; Biwer, C. M.; Day, D.; Flanigan, J.; Kaplan, D. L. [Physics Department, University of Wisconsin-Milwaukee, Milwaukee, WI 53211 (United States); Boyles, J. [Department of Physics and Astronomy, Western Kentucky University, Bowling Green, KY 42101 (United States); Hessels, J. W. T.; Kondratiev, V. I., E-mail: stovall.kevin@gmail.com [ASTRON, the Netherlands Institute for Radio Astronomy, Postbus 2, 7990 AA Dwingeloo (Netherlands); and others

    2014-08-10

    We describe an ongoing search for pulsars and dispersed pulses of radio emission, such as those from rotating radio transients (RRATs) and fast radio bursts, at 350 MHz using the Green Bank Telescope. With the Green Bank Ultimate Pulsar Processing Instrument, we record 100 MHz of bandwidth divided into 4096 channels every 81.92 μs. This survey will cover the entire sky visible to the Green Bank Telescope (δ > –40°, or 82% of the sky) and outside of the Galactic Plane will be sensitive enough to detect slow pulsars and low dispersion measure (<30 pc cm{sup –3}) millisecond pulsars (MSPs) with a 0.08 duty cycle down to 1.1 mJy. For pulsars with a spectral index of –1.6, we will be 2.5 times more sensitive than previous and ongoing surveys over much of our survey region. Here we describe the survey, the data analysis pipeline, initial discovery parameters for 62 pulsars, and timing solutions for 5 new pulsars. PSR J0214+5222 is an MSP in a long-period (512 days) orbit and has an optical counterpart identified in archival data. PSR J0636+5129 is an MSP in a very short-period (96 minutes) orbit with a very low mass companion (8 M{sub J}). PSR J0645+5158 is an isolated MSP with a timing residual RMS of 500 ns and has been added to pulsar timing array experiments. PSR J1434+7257 is an isolated, intermediate-period pulsar that has been partially recycled. PSR J1816+4510 is an eclipsing MSP in a short-period orbit (8.7 hr) and may have recently completed its spin-up phase.

  16. A Scintillometer Assembly for Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Dissing, E; Landstroem, O

    1965-12-15

    An instrument for gamma radiation measurements in connection with geological survey is described. It consists of a scintillation detector with a 5x6 inch sodium iodide crystal and a pulse height analyzer with four independent channels. In field survey work these channels are usually set in fixed positions to record different components of the gamma radiation simultaneously in order to facilitate an identification of the radioactive mineral from which the radiation originates. However, the instrument can also be used for more detailed study of gamma spectra either in the field or in the laboratory. The methods for interpretation of gamma spectra from radioactive ores are briefly reviewed, and a few typical results are given from car-borne and air-borne surveys.

  17. A Scintillometer Assembly for Geological Survey

    International Nuclear Information System (INIS)

    Dissing, E.; Landstroem, O.

    1965-12-01

    An instrument for gamma radiation measurements in connection with geological survey is described. It consists of a scintillation detector with a 5x6 inch sodium iodide crystal and a pulse height analyzer with four independent channels. In field survey work these channels are usually set in fixed positions to record different components of the gamma radiation simultaneously in order to facilitate an identification of the radioactive mineral from which the radiation originates. However, the instrument can also be used for more detailed study of gamma spectra either in the field or in the laboratory. The methods for interpretation of gamma spectra from radioactive ores are briefly reviewed, and a few typical results are given from car-borne and air-borne surveys

  18. The Extended Northern ROSAT Galaxy Cluster Survey (NORAS II). I. Survey Construction and First Results

    International Nuclear Information System (INIS)

    Böhringer, Hans; Chon, Gayoung; Trümper, Joachim; Retzlaff, Jörg; Meisenheimer, Klaus; Schartel, Norbert

    2017-01-01

    As the largest, clearly defined building blocks of our universe, galaxy clusters are interesting astrophysical laboratories and important probes for cosmology. X-ray surveys for galaxy clusters provide one of the best ways to characterize the population of galaxy clusters. We provide a description of the construction of the NORAS II galaxy cluster survey based on X-ray data from the northern part of the ROSAT All-Sky Survey. NORAS II extends the NORAS survey down to a flux limit of 1.8 × 10 −12 erg s −1 cm −2 (0.1–2.4 keV), increasing the sample size by about a factor of two. The NORAS II cluster survey now reaches the same quality and depth as its counterpart, the southern REFLEX II survey, allowing us to combine the two complementary surveys. The paper provides information on the determination of the cluster X-ray parameters, the identification process of the X-ray sources, the statistics of the survey, and the construction of the survey selection function, which we provide in numerical format. Currently NORAS II contains 860 clusters with a median redshift of z  = 0.102. We provide a number of statistical functions, including the log N –log S and the X-ray luminosity function and compare these to the results from the complementary REFLEX II survey. Using the NORAS II sample to constrain the cosmological parameters, σ 8 and Ω m , yields results perfectly consistent with those of REFLEX II. Overall, the results show that the two hemisphere samples, NORAS II and REFLEX II, can be combined without problems into an all-sky sample, just excluding the zone of avoidance.

  19. The Extended Northern ROSAT Galaxy Cluster Survey (NORAS II). I. Survey Construction and First Results

    Energy Technology Data Exchange (ETDEWEB)

    Böhringer, Hans; Chon, Gayoung; Trümper, Joachim [Max-Planck-Institut für Extraterrestrische Physik, D-85748 Garching (Germany); Retzlaff, Jörg [ESO, D-85748 Garching (Germany); Meisenheimer, Klaus [Max-Planck-Institut für Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Schartel, Norbert [ESAC, Camino Bajo del Castillo, Villanueva de la Cañada, E-28692 Madrid (Spain)

    2017-05-01

    As the largest, clearly defined building blocks of our universe, galaxy clusters are interesting astrophysical laboratories and important probes for cosmology. X-ray surveys for galaxy clusters provide one of the best ways to characterize the population of galaxy clusters. We provide a description of the construction of the NORAS II galaxy cluster survey based on X-ray data from the northern part of the ROSAT All-Sky Survey. NORAS II extends the NORAS survey down to a flux limit of 1.8 × 10{sup −12} erg s{sup −1} cm{sup −2} (0.1–2.4 keV), increasing the sample size by about a factor of two. The NORAS II cluster survey now reaches the same quality and depth as its counterpart, the southern REFLEX II survey, allowing us to combine the two complementary surveys. The paper provides information on the determination of the cluster X-ray parameters, the identification process of the X-ray sources, the statistics of the survey, and the construction of the survey selection function, which we provide in numerical format. Currently NORAS II contains 860 clusters with a median redshift of z  = 0.102. We provide a number of statistical functions, including the log N –log S and the X-ray luminosity function and compare these to the results from the complementary REFLEX II survey. Using the NORAS II sample to constrain the cosmological parameters, σ {sub 8} and Ω{sub m}, yields results perfectly consistent with those of REFLEX II. Overall, the results show that the two hemisphere samples, NORAS II and REFLEX II, can be combined without problems into an all-sky sample, just excluding the zone of avoidance.

  20. Site Specific Advisory Board initiative, evaluation survey results supplementary appendix: Summary of individual site results

    International Nuclear Information System (INIS)

    1996-08-01

    This Appendix presents results of the Site-Specific Advisory Board (SSAB) Initiative for each of the 11 sites that participated in the survey. These individual results are a supplement to the June 1996 Summary Report which presented overall survey results. Results are presented in 11 sections, arranged alphabetically by site. Each section includes a series of figures and tables that parallel those presented in the Summary Report. To facilitate comparison, figures are presented both for the individual site and for the overall long survey. The sequence of sections is: Fernald, Hanford, Idaho, Los Alamos, Monticello, Nevada, Pantex, Rocky Flats, St. Louis, Sandia, and Savannah River

  1. First results from the hot plasma instrument PROMICS-3 on Interball-2

    Directory of Open Access Journals (Sweden)

    I. Sandahl

    1999-05-01

    Full Text Available The PROMICS-3 instrument on Interball-2 is nominally identical to the PROMICS-3 instrument on Interball-1. It performs three-dimensional measurements of ions in the energy range 4 eV-70 keV with mass separation and of electrons in the energy range 300 eV-35 keV. Interball-2 was launched on August 29, 1996, into an orbit with the same inclination as that of Interball-1, 63°, but with apogee at 20 000 km. In this study the PROMICS-3 instrument on Interball-2 is briefly described and examples of the first results are presented. Firstly, we report observations of upward moving molecular ions with energies of up to 700 eV at the poleward edge of the auroral oval. Previous observations of outflowing molecular ions have been at lower altitudes and lower energies. Secondly, we show observations of dawnside magnetosheath plasma injections. Using conjugate data from both PROMICS-3 instruments we have found dispersion structures above the morningside auroral oval, which occurred simultaneously with isolated "pockets" of magnetosheath plasma at a distance of XGSM=-14 to -12 RE, which had been injected into the inner part of the low-latitude boundary layer. These isolated plasma structures were sites of strong field-aligned currents and are proposed to be the magnetospheric counterparts of the dispersion structures.Key words. Magnetospheric physics (auroral phenomena; magnetotail boundary layers; instruments and techniques.

  2. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    Science.gov (United States)

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  3. ARABIC TRANSLATION AND ADAPTATION OF THE HOSPITAL CONSUMER ASSESSMENT OF HEALTHCARE PROVIDERS AND SYSTEMS (HCAHPS) PATIENT SATISFACTION SURVEY INSTRUMENT.

    Science.gov (United States)

    Dockins, James; Abuzahrieh, Ramzi; Stack, Martin

    2015-01-01

    To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P quarterly to US national averages with results that closely paralleled the US benchmarks. . The Arabic translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.

  4. Nuclear instrument maintenance - problems, solutions, and obstacles

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1983-01-01

    In 200 laboratories of South-East Asia, Latin America and Africa a survey was made of the state of instrumentation for nuclear medicine. The principal cause of failures and defects was inadequate quality control and preventive maintenance. On the basis of the survey coordinated research programs were compiled for the maintenance of nuclear instruments. The four principal points of the programs are: to safeguard quality and stable electric power supplies for the instruments, to safeguard permanent temperature and humidity in the environment in which the equipment is operated, effective maintenance, and training of personnel. In the years 1981 and 1982, 14 local training courses were run in which emphasis was put on practicals and tests in mechanics and electronics

  5. Minimum detectable activities of contamination control survey equipment

    International Nuclear Information System (INIS)

    Goles, R.W.; Baumann, B.L.; Johnson, M.L.

    1991-08-01

    The Instrumentation ampersand External Dosimetry (I ampersand ED) Section of the Health Physics Department at the Pacific Northwest Laboratory (PNL) has performed a series of tests to determine the ability of portable survey instruments used at Hanford to detect radioactive contamination at levels required by DOE 5480.11. This semi-empirical study combines instrumental, statistical, and human factors as necessary to derive operational detection limits. These threshold detection values have been compared to existing contamination control requirements, and detection deficiencies have been identified when present. Portable survey instruments used on the Hanford Site identify the presence of radioactive surface contamination based on the detection of α-, β-, γ-, and/or x-radiation. However, except in some unique circumstances, most contamination monitors in use at Hanford are configured to detect either α-radiation alone or β- and γ-radiation together. Testing was therefore conducted on only these two categories of radiation detection devices. Nevertheless, many of the results obtained are generally applicable to all survey instruments, allowing performance evaluations to be extended to monitoring devices which are exclusively γ- and/or x-ray- sensitive. 6 figs., 2 tabs

  6. Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps

    CERN Document Server

    Adam, R.; Aghanim, N.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bertincourt, B.; Bielewicz, P.; Bock, J.J.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bucher, M.; Burigana, C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chiang, H.C.; Christensen, P.R.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T.A.; Eriksen, H.K.; Falgarone, E.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Ghosh, T.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, A.H.; Jaffe, T.R.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C.R.; Le Jeune, M.; Leahy, J.P.; Lellouch, E.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Moreno, R.; Morgante, G.; Mortlock, D.; Moss, A.; Mottet, S.; Munshi, D.; Murphy, J.A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Pearson, T.J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J.P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J.A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Wade, L.A.; Wandelt, B.D.; Watson, R.; Wehus, I.K.; Yvon, D.; Zacchei, A.

    2016-01-01

    This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the 2.5 year full mission include almost five independent full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To get the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole which we call the orbital dipole. This source of calibration only depends on the satellite velocity with respect to the solar system and permits an independent measurement of the amplitude of the CMB solar dipole (3364.5 +/- 0.8 \\mu K) which is 1\\sigma\\ higher than the WMAP measurement wit...

  7. The Complexity integrated-Instruments components media of IPA at Elementary School

    Directory of Open Access Journals (Sweden)

    Angreni Siska

    2018-01-01

    Full Text Available This research aims at describing the complexity of Integrated Instrument Components media (CII in learning of science at Elementary schools in District Siulak Mukai and at Elementary schools in District Siulak. The research applied a descriptive method which included survey forms. Instruments used were observation sheets. The result of the research showed Integrated Instrument Components media (CII natural science that complexity at primary school district Siulak was more complex compared with that at primary school district Siulak Mukai. is better than from primary school district Mukai

  8. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  9. Results from the 2013 drug and alcohol testing survey.

    Science.gov (United States)

    2015-12-01

    This report summarizes the results of the 2013 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) that test positive fo...

  10. Results from the 2008 Drug and Alcohol Testing Survey

    Science.gov (United States)

    2010-01-01

    This report summarizes the results of the 2008 Federal Motor Carrier Safety Administration Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses who test positive for controlled sub...

  11. Online Student Evaluation Improves Course Experience Questionnaire Results in a Physiotherapy Program

    Science.gov (United States)

    Tucker, Beatrice; Jones, Sue; Straker, Leon

    2008-01-01

    This paper reports the use of an online student evaluation system, Course Experience on the Web (CEW), in a physiotherapy program to improve their Course Experience Questionnaire (CEQ) results. CEW comprises a course survey instrument modeled on the CEQ and a tailored unit survey instrument. Closure of the feedback loop is integral in the CEW…

  12. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  13. PTAC driving safety survey results

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, E. [Petroleum Technology Alliance Canada, Calgary, AB (Canada)

    2005-07-01

    The results of a survey conducted by the Petroleum Technology Alliance Canada were presented. The survey identified ways in which companies in the oil and gas industry can reduce the potential for vehicle incidents, as well as improve fleet management techniques. Respondents provided a list of over 60 relevant technologies with high potential for application. Top driving safety challenges included adverse weather and road conditions, as well as driver attitude and awareness. Driver speed and fatigue were also seen as significant challenges, as well as encounters with wildlife and road conditions. Poor site conditions were also identified as a challenge, along with poor hazard recognition training, and lack of experience. A total of 157 representatives responded, whose fleets collectively drive approximately 136,500,000 km per year. The fleets totalled 15,800 vehicles. Respondents' affiliations with the oil and gas industry were included, as well as ownership classifications and company fleet sizes. Total annual fleet kilometers were presented, as well as the number of incidents per company per year, along with the number of respondents' animal strikes per year. tabs, figs.

  14. Results of radioactivity surveys in Miyagi Prefecture

    International Nuclear Information System (INIS)

    1983-01-01

    The results of radioactivity surveys carried out in Miyagi Prefecture in fiscal 1981 (from April, 1981, to March, 1982), entrusted by the Science and Technology Agency, are presented in tables: total β radioactivity in rainwater, in rainwater and dust collected by large basins, in daily foods, in land water, in dairy products and vegetables, in marine products and in soil, 131 I nuclide in cow's milk, air γ-ray dose rate by survey meters, and air γ-ray counting, rate by a monitoring post were examined. The total β radioactivity was measured by a GM counting apparatus with an automatic sample changer, the nuclide analysis by a NaI(Tl) scintillation spectrometer, the air γ-ray dose rate by a NaI(Tl) scintillation survey meter, and the γ-ray counting rate by a NaI(Tl) scintillation type monitoring post. (Mori, K.)

  15. Ninth Triennial Toxicology Salary Survey.

    Science.gov (United States)

    Gad, Shayne Cox; Sullivan, Dexter Wayne

    2016-01-01

    This survey serves as the ninth in a series of toxicology salary surveys conducted at 3-year intervals and beginning in 1988. An electronic survey instrument was distributed to 5919 individuals including members of the Society of Toxicology, American College of Toxicology, and 23 additional professional organizations. Question items inquired about gender, age, degree, years of experience, certifications held, areas of specialization, society membership, employment and income. Overall, 1293 responses were received (response rate 21.8%). The results of the 2014 survey provide insight into the job market and career path for current and future toxicologists. © The Author(s) 2016.

  16. Review of decametric radio astronomy - instruments and science

    International Nuclear Information System (INIS)

    Erickson, W.C.; Cane, H.V.

    1987-01-01

    The techniques and instruments used in Galactic and extragalactic radio astronomy at dkm wavelengths are surveyed, and typical results are summarized. Consideration is given to the large specialized phased arrays used for early surveys, the use of wideband elements to increase frequency agility, experimental VLBI observations, and limitations on ground-based observations below about 10 MHz (where the proposed LF Space Array, with resolution 0.5-5 arcmin, could make a major contribution). Observations discussed cover the Galactic center, the Galactic background radiation, SNRs, compact Galactic sources, the ISM, and large extragalactic sources. 38 references

  17. Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities

    International Nuclear Information System (INIS)

    Lindborg, L.; Bolognese-Milsztajn, T.; Boschung, M.; Coeck, M.; Curzio, G.; D'Errico, F.; Fiechtner, A.; Hallfarth, D.; Lievens, B.; Lillhoek, J. E.; Loevefors-Daun, A.; Lacoste, V.; Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Tanner, R.; Vanhavere, F.

    2007-01-01

    Ratios of H p (10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H p (10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract. (authors)

  18. Quality Control in Survey Design: Evaluating a Survey of Educators’ Attitudes Concerning Differentiated Compensation

    OpenAIRE

    Kelly D. Bradley; Michael Peabody; Shannon O. Sampson

    2015-01-01

    This study utilized the Rasch model to assess the quality of a survey instrument designed to measure attitudes of administrators and teachers concerning a differentiated teacher compensation program piloted in Kentucky.  Researchers addressing potentially contentious issues should ensure their methods stand up to rigorous criticism.  The results indicate that the rating scale does not function as expected, with items being too easy to endorse.  Future iterations of this survey should be revis...

  19. The Impact of Knowledge Management Practices on NPP Organizational Performance - Results of a Global Survey

    International Nuclear Information System (INIS)

    2013-06-01

    The IAEA has been asked by Member States in the 2012 General Conference Resolutions to ''further increase the level of awareness of efforts in managing nuclear knowledge'' and to continue ''to further develop and disseminate guidance and methodologies for planning, designing, and implementing nuclear knowledge management programs''. The present report summarizes the results of empirical research on the relationship between KM practices in nuclear power plants, their impact on the quality of organizational knowledge processes and the resulting effects on the organizational effectiveness of nuclear power plants. It presents the basic findings of the ''IAEA Global Nuclear Power Plant Survey: Investigating the Link Between Knowledge Management Practices and Organizational Performance'', which was conducted in 2010. This benchmark survey of KM practices in nuclear power plants was developed using a standard research methodology. The survey was made available on a global basis to all nuclear power plant sites. Senior operations managers were asked to complete the survey with input, as required, from their plant management team. Data from individual survey responses were treated as confidential, and only aggregate findings were reported. A total of 124 station ''site organizations'' participated in the survey, representing a response rate of approximately 60%. The findings provide empirical evidence of the importance of KM practices in improving the organizational effectiveness of nuclear power plants. They provide information about the current state of the industry with respect to KM practices, illustrating the direct and tangible benefits of implementing such practices and justifying continued or further efforts to ensure that KM programmes and systems are strategically planned and implemented in operating nuclear power plants. The research provides insights into the mechanisms by which KM practices have an impact on organizational effectiveness and provides a basis for

  20. Maintaining Oversight of Licensee Safety Culture. CSNI/WGHOF Survey Results

    International Nuclear Information System (INIS)

    2008-01-01

    In preparation for this workshop, a survey was sent to members of the WGHOF in Autumn 2006. Purpose of the Survey was to explore and share the methods and approaches used to maintain oversight of licensee safety culture. 13 countries responded to the survey. The responses were used in the development of discussion topics and themes for this workshop. This presentation (slides) summarizes the results of the survey

  1. Optimising the effect of policy instruments

    DEFF Research Database (Denmark)

    Pedersen, Anders Branth; Nielsen, Helle Ørsted; Christensen, Tove

    2012-01-01

    Economic modelling generally assumes that businesses are profit maximisers. However, behavioural economics holds that businesses pursue multiple objectives and may even sacrifice some profit. This has implications for the effectiveness of incentive-based environmental policies. Using Danish farme...... to policy instruments; farmers who focus on yield indicate less responsiveness to economic policy instruments. The results imply that it is important to implement a broad array of policy instruments to match different farmer rationales.......Economic modelling generally assumes that businesses are profit maximisers. However, behavioural economics holds that businesses pursue multiple objectives and may even sacrifice some profit. This has implications for the effectiveness of incentive-based environmental policies. Using Danish farmers...... as a case, this paper examines whether non-economic rationales may trump economic ones in farmer decisions, and, unlike previous research, we quantify how widespread non-economic values are compared to more economic values. Data derive from a survey (1164 responses) of Danish conventional farmers' decision...

  2. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  3. Update of Earthquake Strong-Motion Instrumentation at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Robert C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-09-01

    Following the January 1980 earthquake that was felt at Lawrence Livermore National Laboratory (LLNL), a network of strong-motion accelerographs was installed at LLNL. Prior to the 1980 earthquake, there were no accelerographs installed. The ground motion from the 1980 earthquake was estimated from USGS instruments around the Laboratory to be between 0.2 – 0.3 g horizontal peak ground acceleration. These instruments were located at the Veterans Hospital, 5 miles southwest of LLNL, and in San Ramon, about 12 miles west of LLNL. In 2011, the Department of Energy (DOE) requested to know the status of our seismic instruments. We conducted a survey of our instrumentation systems and responded to DOE in a letter. During this survey, it was found that the recorders in Buildings 111 and 332 were not operational. The instruments on Nova had been removed, and only three of the 10 NIF instruments installed in 2005 were operational (two were damaged and five had been removed from operation at the request of the program). After the survey, it was clear that the site seismic instrumentation had degraded substantially and would benefit from an overhaul and more attention to ongoing maintenance. LLNL management decided to update the LLNL seismic instrumentation system. The updated system is documented in this report.

  4. The XXL Survey: First Results and Future

    Science.gov (United States)

    Pierre, M.; Adami, C.; Birkinshaw, M.; Chiappetti, L.; Ettori, S.; Evrard, A.; Faccioli, L.; Gastaldello, F.; Giles, P.; Horellou, C.; hide

    2017-01-01

    The XXL survey currently covers two 25 deg2 patches with XMM observations of approximately 10 ks. We summarize the scientific results associated with the first release of the XXL dataset, which occurred in mid-2016.We review several arguments for increasing the survey depth to 40 ks during the next decade of XMM operations. X-ray(zeta less than 2) cluster, (zeta less than 4) active galactic nuclei (AGN), and cosmic background survey science will then benefit from an extraordinary data reservoir. This, combined with deep multi-lambda observations, will lead to solid standalone cosmological constraints and provide a wealth of information on the formation and evolution of AGN, clusters, and the X-ray background. In particular, it will offer a unique opportunity to pinpoint the zeta greater than1 cluster density. It will eventually constitute a reference study and an ideal calibration field for the upcoming eROSITA and Euclid missions.

  5. Joint NRC/EPA Sewage Sludge Radiological Survey: Survey Design & Test Site Results

    Science.gov (United States)

    This report contains the results of a radiological survey of nine publicly POTWs around the country, which was commissioned by the Sewage Sludge Subcommittee, to determine whether and to what extent radionuclides concentrate in sewage treatment wastes.

  6. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  7. First results of Chinese particle instruments in the Double Star Program

    Directory of Open Access Journals (Sweden)

    J. B. Cao

    2005-11-01

    Full Text Available Double Star Program (DSP aims to investigate the trigger mechanism and physical models of geomagnetic storms and substorms. The DSP involves two satellites: the equatorial satellite of DSP (TC-1 in China and the polar satellite of DSP (TC-2 in China. On board the two satellites of TC-1 and TC-2, there are four kinds of particle instruments developed by the Center for Space Science and Applied Research (CSSAR, namely: the High Energy Electron Detector (HEED, TC-1, 2, the High Energy Proton Detector (HEPD, TC-1, 2, the High Energy Heavy Ion Detector (HID, TC-1, 2 and the Low Energy Ion Detector (LEID, TC-2. HEED, HEPD and HID were developed and calibrated in China. The LEID was developed in China and calibrated in France. This paper introduces the scientific objectives and characteristics of each instrument, their status and some preliminary results.

  8. Construction practices: Pulse builder survey results

    Energy Technology Data Exchange (ETDEWEB)

    Kadulski, R

    This paper discusses the results of a nationwide builder survey on common building techniques, such as framing, insulation, airtight construction practices, testing for airtightness, windows, furnaces and water heaters, and ventilation. Results indicate that changes in construction were mainly influenced by the R-2000 program. The spread of R-2000 technology is reflected in the use of higher insulation levels than are called for by codes or than is normal practice, sealing of joints, and attention to air and vapour retarders as well as air tight drywall techniques combined with mechanical ventilation systems.

  9. Diabetes and quality of life: Comparing results from utility instruments and Diabetes-39.

    Science.gov (United States)

    Chen, Gang; Iezzi, Angelo; McKie, John; Khan, Munir A; Richardson, Jeff

    2015-08-01

    To compare the Diabetes-39 (D-39) with six multi-attribute utility (MAU) instruments (15D, AQoL-8D, EQ-5D, HUI3, QWB, and SF-6D), and to develop mapping algorithms which could be used to transform the D-39 scores into the MAU scores. Self-reported diabetes sufferers (N=924) and members of the healthy public (N=1760), aged 18 years and over, were recruited from 6 countries (Australia 18%, USA 18%, UK 17%, Canada 16%, Norway 16%, and Germany 15%). Apart from the QWB which was distributed normally, non-parametric rank tests were used to compare subgroup utilities and D-39 scores. Mapping algorithms were estimated using ordinary least squares (OLS) and generalised linear models (GLM). MAU instruments discriminated between diabetes patients and the healthy public; however, utilities varied between instruments. The 15D, SF-6D, AQoL-8D had the strongest correlations with the D-39. Except for the HUI3, there were significant differences by gender. Mapping algorithms based on the OLS estimator consistently gave better goodness-of-fit results. The mean absolute error (MAE) values ranged from 0.061 to 0.147, the root mean square error (RMSE) values 0.083 to 0.198, and the R-square statistics 0.428 and 0.610. Based on MAE and RMSE values the preferred mapping is D-39 into 15D. R-square statistics and the range of predicted utilities indicate the preferred mapping is D-39 into AQoL-8D. Utilities estimated from different MAU instruments differ significantly and the outcome of a study could depend upon the instrument used. The algorithms reported in this paper enable D-39 data to be mapped into utilities predicted from any of six instruments. This provides choice for those conducting cost-utility analyses. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  11. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  12. How neuroscience is taught to North American dental students: results of the Basic Science Survey Series.

    Science.gov (United States)

    Gould, Douglas J; Clarkson, Mackenzie J; Hutchins, Bob; Lambert, H Wayne

    2014-03-01

    The purpose of this study was to determine how North American dental students are taught neuroscience during their preclinical dental education. This survey represents one part of a larger research project, the Basic Science Survey Series for Dentistry, which covers all of the biomedical science coursework required of preclinical students in North American dental schools. Members of the Section on Anatomical Sciences of the American Dental Education Association assembled, distributed, and analyzed the neuroscience survey, which had a 98.5 percent response from course directors of the sixty-seven North American dental schools. The eighteen-item instrument collected demographic data on the course directors, information on the content in each course, and information on how neuroscience content is presented. Findings indicate that 1) most neuroscience instruction is conducted by non-dental school faculty members; 2) large content variability exists between programs; and 3) an increase in didactic instruction, integrated curricula, and use of computer-aided instruction is occurring. It is anticipated that the information derived from the survey will help guide neuroscience curricula in dental schools and aid in identifying appropriate content.

  13. Using New Technologies for Time Diary Data Collection: Instrument Design and Data Quality Findings from a Mixed-Mode Pilot Survey.

    Science.gov (United States)

    Chatzitheochari, Stella; Fisher, Kimberly; Gilbert, Emily; Calderwood, Lisa; Huskinson, Tom; Cleary, Andrew; Gershuny, Jonathan

    2018-01-01

    Recent years have witnessed a steady growth of time-use research, driven by the increased research and policy interest in population activity patterns and their associations with long-term outcomes. There is recent interest in moving beyond traditional paper-administered time diaries to use new technologies for data collection in order to reduce respondent burden and administration costs, and to improve data quality. This paper presents two novel diary instruments that were employed by a large-scale multi-disciplinary cohort study in order to obtain information on the time allocation of adolescents in the United Kingdom. A web-administered diary and a smartphone app were created, and a mixed-mode data collection approach was followed: cohort members were asked to choose between these two modes, and those who were unable or refused to use the web/app modes were offered a paper diary. Using data from a pilot survey of 86 participants, we examine diary data quality indicators across the three modes. Results suggest that the web and app modes yield an overall better time diary data quality than the paper mode, with a higher proportion of diaries with complete activity and contextual information. Results also show that the web and app modes yield a comparable number of activity episodes to the paper mode. These results suggest that the use of new technologies can improve diary data quality. Future research using larger samples should systematically investigate selection and measurement effects in mixed-mode time-use survey designs.

  14. PEP Laser Surveying System

    International Nuclear Information System (INIS)

    Lauritzen, T.; Sah, R.C.

    1979-03-01

    A Laser Surveying System has been developed to survey the beam elements of the PEP storage ring. This system provides automatic data acquisition and analysis in order to increase survey speed and to minimize operator error. Two special instruments, the Automatic Readout Micrometer and the Small Automatic Micrometer, have been built for measuring the locations of fiducial points on beam elements with respect to the light beam from a laser. These instruments automatically encode offset distances and read them into the memory of an on-line computer. Distances along the beam line are automatically encoded with a third instrument, the Automatic Readout Tape Unit. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compared them with desired parameters, and calculates the required adjustments to beam element support stands

  15. Online Calculus: The Course and Survey Results.

    Science.gov (United States)

    Allen, G. Donald

    2001-01-01

    Describes the development and implementation of a Web-based calculus course at Texas A & M University. Discusses the course design, layout of content and the contrast with textbook structure, results of course surveys that included student reactions, and how students learn form Web-based materials. (Author/LRW)

  16. Integrated alarm annunciation and entry control systems -- Survey results

    International Nuclear Information System (INIS)

    Clever, J.J.; Arakaki, L.H.; Monaco, F.M.; Juarros, L.E.; Quintana, G.R.

    1993-10-01

    This report provides the results and analyses of a detailed survey undertaken in Summer 1993 to address integrated intrusion detection alarm annunciation and entry control system issues. This survey was undertaken as a first attempt toward beginning to answer questions about integrated systems and commercial capabilities to meet or partially meet US Department of Energy (DOE) site needs

  17. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  18. Impact of the Medical Faculty on Study Success in Freiburg: Results from Graduate Surveys

    Directory of Open Access Journals (Sweden)

    Biller, Silke

    2015-10-01

    Full Text Available Aim: Using the data from graduate surveys, this study aims to analyze which factors related to teaching and learning at the Freiburg Faculty of Medicine can influence study success.Background: Study success and the factors influencing it have long been the subject of investigation, with study success being measured in terms of easily quantifiable indicators (final grades, student satisfaction, etc.. In recent years, it has also frequently been assessed in terms of graduate competency levels. Graduate surveys are considered suitable instruments for measuring these dimensions of study success.Method: Data from three Freiburg graduate surveys conducted one and a half years after graduation were drawn upon for the analysis.Study success was operationalized using four indicators: results on the written section of the M2 exam, self-assessment of medical expertise and scientific expertise, and student satisfaction. Using multiple regression analyses, the predictive power was calculated for selected variables, also measured by the graduate surveys, for the different study success indicators.Results: It was possible to identify models that contribute slightly or moderately to the prediction of study success. The score earned on the university entrance qualification demonstrated itself to be the strongest predictor for forecasting the M2 written exam: R is between 0.08 and 0.22 for the three surveys. Different variables specific to degree program structure and teaching are helpful for predicting medical expertise (R=0.04-0.32 and student satisfaction (R=0.12-0.35. The two variables, and , show themselves to be significant, sample-invariant predictors (β-weight=0.21-0.58, β-weight=0.27-0.56. For scientific expertise, no sample-independent predictors could be determined.Conclusion: Factors describing teaching hardly provide any assistance when predicting the written M2 exam score, which makes sense to the extent that teaching goes far beyond the heavily

  19. The Dark Energy Survey instrument design

    International Nuclear Information System (INIS)

    Flaugher, B.; Fermilab

    2006-01-01

    We describe a new project, the Dark Energy Survey (DES), aimed at measuring the dark energy equation of state parameter, w, to a statistical precision of ∼5%, with four complementary techniques. The survey will use a new 3 sq. deg. mosaic camera (DECam) mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). DECam includes a large mosaic camera, a five element optical corrector, four filters (g,r,i,z), and the associated infrastructure for operation in the prime focus cage. The focal plane consists of 62 2K x 4K CCD modules (0.27''/pixel) arranged in a hexagon inscribed within the 2.2 deg. diameter field of view. We plan to use the 250 micron thick fully-depleted CCDs that have been developed at the Lawrence Berkeley National Laboratory (LBNL). At Fermilab, we will establish a packaging factory to produce four-side buttable modules for the LBNL devices, as well as to test and grade the CCDs. R and D is underway and delivery of DECam to CTIO is scheduled for 2009

  20. Comparison of Satellite Surveying to Traditional Surveying Methods for the Resources Industry

    Science.gov (United States)

    Osborne, B. P.; Osborne, V. J.; Kruger, M. L.

    Modern ground-based survey methods involve detailed survey, which provides three-space co-ordinates for surveyed points, to a high level of accuracy. The instruments are operated by surveyors, who process the raw results to create survey location maps for the subject of the survey. Such surveys are conducted for a location or region and referenced to the earth global co- ordinate system with global positioning system (GPS) positioning. Due to this referencing the survey is only as accurate as the GPS reference system. Satellite survey remote sensing utilise satellite imagery which have been processed using commercial geographic information system software. Three-space co-ordinate maps are generated, with an accuracy determined by the datum position accuracy and optical resolution of the satellite platform.This paper presents a case study, which compares topographic surveying undertaken by traditional survey methods with satellite surveying, for the same location. The purpose of this study is to assess the viability of satellite remote sensing for surveying in the resources industry. The case study involves a topographic survey of a dune field for a prospective mining project area in Pakistan. This site has been surveyed using modern surveying techniques and the results are compared to a satellite survey performed on the same area.Analysis of the results from traditional survey and from the satellite survey involved a comparison of the derived spatial co- ordinates from each method. In addition, comparisons have been made of costs and turnaround time for both methods.The results of this application of remote sensing is of particular interest for survey in areas with remote and extreme environments, weather extremes, political unrest, poor travel links, which are commonly associated with mining projects. Such areas frequently suffer language barriers, poor onsite technical support and resources.

  1. Considerations in comparing the U.S. Geological Survey one‐year induced‐seismicity hazard models with “Did You Feel It?” and instrumental data

    Science.gov (United States)

    White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie

    2017-01-01

    The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.

  2. Medical Simulation Practices 2010 Survey Results

    Science.gov (United States)

    McCrindle, Jeffrey J.

    2011-01-01

    Medical Simulation Centers are an essential component of our learning infrastructure to prepare doctors and nurses for their careers. Unlike the military and aerospace simulation industry, very little has been published regarding the best practices currently in use within medical simulation centers. This survey attempts to provide insight into the current simulation practices at medical schools, hospitals, university nursing programs and community college nursing programs. Students within the MBA program at Saint Joseph's University conducted a survey of medical simulation practices during the summer 2010 semester. A total of 115 institutions responded to the survey. The survey resus discuss overall effectiveness of current simulation centers as well as the tools and techniques used to conduct the simulation activity

  3. The 2003 Australian Breast Health Survey: survey design and preliminary results

    Directory of Open Access Journals (Sweden)

    Favelle Simone

    2008-01-01

    Full Text Available Abstract Background The Breast Health Surveys, conducted by the National Breast Cancer Centre (NBCC in 1996 and 2003, are designed to gain insight into the knowledge, attitudes and behaviours of a nationally representative sample of Australian women on issues relevant to breast cancer. In this article, we focus on major aspects of the design and present results on respondents' knowledge about mammographic screening. Methods The 2003 BHS surveyed English-speaking Australian women aged 30–69 without a history of breast cancer using computer-assisted telephone interviewing. Questions covered the following themes: knowledge and perceptions about incidence, mortality and risk; knowledge and behaviour regarding early detection, symptoms and diagnosis; mammographic screening; treatment; and accessibility and availability of information and services. Respondents were selected using a complex sample design involving stratification. Sample weights against Australian population benchmarks were used in all statistical analyses. Means and proportions for the entire population and by age group and area of residence were calculated. Statistical tests were conducted using a level of significance of 0.01. Results Of the 3,144 respondents who consented to being interviewed, 138 (4.4% had a previous diagnosis of breast cancer and were excluded leaving 3,006 completed interviews eligible for analysis. A majority of respondents (61.1% reported ever having had a mammogram and 29.1% identified mammography as being the best way of finding breast cancer. A majority of women (85.9% had heard of the BreastScreen Australia (BSA program, the national mammographic screening program providing free biennial screening mammograms, with 94.5% believing that BSA attendance was available regardless of the presence or absence of symptoms. There have been substantial gains in women's knowledge about mammographic screening over the seven years between the two surveys. Conclusion The

  4. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    Science.gov (United States)

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  5. Results and lessons from the GMOS survey of transiting exoplanet atmospheres

    Science.gov (United States)

    Todorov, Kamen; Desert, Jean-Michel; Huitson, Catherine; Bean, Jacob; Fortney, Jonathan; Bergmann, Marcel; Stevenson, Kevin

    2018-01-01

    We present results from the first comprehensive survey program dedicated to probing transiting exoplanet atmospheres using transmission spectroscopy with a multi-object spectrograph (MOS). Our four-years survey focussed on ten close-in giant planets for which the wavelength dependent transit depths in the visible were measured with Gemini/GMOS. We present the complete analysis of all the targets observed (50 transits, 300 hours), and the challenges to overcome to achieve the best spectrophotometric precision (200-500 ppm / 10 nm). We also present the main results and conclusions from this survey. We show that the precision achieved by this survey permits to distinguish hazy atmospheres from cloud-free ones. We discuss the challenges faced by such an experiment, and the lessons learnt for future MOS survey. We lay out the challenges facing future ground based MOS transit surveys aiming for the atmospheric characterization of habitable worlds, and utilizing the next generation of multi-object spectrographs mounted on extremely large ground based telescopes (ELT, TMT).

  6. A summary of the performance of exposure rate and dose rate instruments contained in instrument evaluation reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report provides a concise summary of measurements of the more important performance characteristics of radiation protection dose rate or exposure rate survey instruments which have been assessed by NRPB as part

  7. Developing an Instrument to Measure Autonomous Adaptive Capacity to Climate Change among Urban Households

    Directory of Open Access Journals (Sweden)

    Kathryn R. Selm

    2018-02-01

    Full Text Available The capacity of households in urban environments to adapt and react to climate change can affect the resilience of the whole community, and instruments for systematically measuring that capacity are needed. We used Raleigh, NC as a case study to explore the dimensions of autonomous adaptive capacity of urban households and to create a scale and associated survey instrument to measure them. Our approach was guided by four capitals that support human livelihoods: social, human, physical, and financial. We surveyed 200 households in Raleigh, NC, and used a principal components analysis to test the scale and survey instrument. Results suggest the scale is a useful and concise tool. Three major dimensions were present among the scale items: financial capital, political awareness, and access to resources. Together, these three dimensions can be used to measure adaptive capacity among different households. These findings are supported by similar work illustrating the value of income inequality and political awareness as indicators of adaptive capacity. Our results also demonstrate that complex relationships among the livelihood capitals may confound our ability to measure financial, physical, and human capitals separately. This framework for assessing adaptive capacity of households, with further refinement and testing, may be used in urban areas to evaluate programs designed to impact resilience to climate change.

  8. Analysis and protective measures of sharp instrument injury causes of sterilization and supply center

    Directory of Open Access Journals (Sweden)

    Hua YANG

    2014-11-01

    Full Text Available Objective: To analyze the causes of sharp injury in the sterilization and supply center, take protective measures, effectively avoid sharp instrument injury, and guarantee staff safety. Methods: Adopt a retrospective survey method, summarize sharp instrument injury data of sterilization and supply center in 2013, analyze the reasons of the occurrence of sharp instrument injury, and make protective countermeasures. Results: Sharp instrument injuries occurred mainly in the device classification, manual cleaning and device packaging process. Conclusion: Poor consciousness of occupational protection of the staff in the sterilization and supply center, nonstandard operation, and lack of training and supervision in place are the main reasons of occurrence of sharp instrument injury.

  9. An instrument to assess subjective task value beliefs regarding the decision to pursue postgraduate training.

    Science.gov (United States)

    Hagemeier, Nicholas E; Murawski, Matthew M

    2014-02-12

    To develop and validate an instrument to assess subjective ratings of the perceived value of various postgraduate training paths followed using expectancy-value as a theoretical framework; and to explore differences in value beliefs across type of postgraduate training pursued and type of pharmacy training completed prior to postgraduate training. A survey instrument was developed to sample 4 theoretical domains of subjective task value: intrinsic value, attainment value, utility value, and perceived cost. Retrospective self-report methodology was employed to examine respondents' (N=1,148) subjective task value beliefs specific to their highest level of postgraduate training completed. Exploratory and confirmatory factor analytic techniques were used to evaluate and validate value belief constructs. Intrinsic, attainment, utility, cost, and financial value constructs resulted from exploratory factor analysis. Cross-validation resulted in a 26-item instrument that demonstrated good model fit. Differences in value beliefs were noted across type of postgraduate training pursued and pharmacy training characteristics. The Postgraduate Training Value Instrument demonstrated evidence of reliability and construct validity. The survey instrument can be used to assess value beliefs regarding multiple postgraduate training options in pharmacy and potentially inform targeted recruiting of individuals to those paths best matching their own value beliefs.

  10. PreCam: A Precursor Observational Campaign for Calibration of the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, K.; Kuhlmann, S.; Allam, S.; Annis, J. T.; Bailey, T.; Balbinot, E.; Bernstein, J. P.; Biesiadzinski, T.; Burke, D. L.; Butner, M.; Camargo, J. I. B.; da Costa, L. A. N.; DePoy, D.; Diehl, H. T.; Dietrich, J. P.; Estrada, J.; Fausti, A.; Gerke, B.; Guarino, V.; Head, H. H.; Kessler, R.; Lin, H.; Lorenzon, W.; Maia, M. A. G.; Maki, L.; Marshall, J.; Nord, B.; Neilsen, E.; Ogando, R. L. C.; Park, D.; Peoples, J.; Rastawicki, D.; Rheault, J. -P.; Santiago, B.; Schubnell, M.; Seitzer, P.; Smith, J. A.; Spinka, H.; Sypniewski, A.; Tarle, G.; Tucker, D. L.; Walker, A. R.; Wester, W.

    2013-04-01

    PreCam, a precursor observational campaign supporting the Dark Energy Survey (DES), is designed to produce a photometric and astrometric catalog of nearly a hundred thousand standard stars within the DES footprint, while the PreCam instrument also serves as a prototype testbed for the Dark Energy Camera's hardware and software. This catalog represents a potential 100-fold increase in Southern Hemisphere photometric standard stars, and therefore will be an important component in the calibration of the Dark Energy Survey. We provide details on the PreCam instrument's design, construction, and testing, as well as results from a subset of the 51 nights of PreCam survey observations on the University of Michigan Department of Astronomy's Curtis-Schmidt telescope at Cerro Tololo Inter-American Observatory (CTIO). We briefly describe the preliminary data processing pipeline that has been developed for PreCam data and the preliminary results of the instrument performance, as well as astrometry and photometry of a sample of stars previously included in other southern sky surveys.

  11. Rural Competitiveness: Results of the 1996 Rural Manufacturing Survey

    OpenAIRE

    Gale, H. Frederick, Jr.; McGranahan, David A.; Teixeira, Ruy; Greenberg, Elizabeth

    1999-01-01

    Establishments in metropolitan and nonmetropolitan locations are surprisingly similar in their adoption of new technologies, worker skill requirements, use of government programs and technical assistance, exports, and sources of financing, according to the results of a nationwide survey of 3,909 manufacturing businesses. The most widespread concern of both metro and nonmetro businesses appears to be with quality of labor. Survey respondents report rapidly increasing skill requirements, and ma...

  12. Measurement equivalence of the food related lifestyle instrument (FRL) in Ireland and Great Britain

    DEFF Research Database (Denmark)

    O´Sullivan, C.; Scholderer, Joachim; Cowan, Cathal

    2005-01-01

    The food-related lifestyle instrument (FRL) is tested for cross-cultural validity. Representative consumer samples from the UK 1998 ( N = 1000) and Ireland 2001 (N = 1024) are compared using multi-sample confirmatory factor analysis with structured means. The results suggest that, in all five FRL...... domains, the measurement characteristics of the survey instrument were completely invariant across the two cultures. No indication was found of any bias. Regarding future applications of the FRL, it can be concluded that the instrument has identical measurement characteristics when applied to consumer...

  13. Field results of antifouling techniques for optical instruments

    Science.gov (United States)

    Strahle, W.J.; Hotchkiss, F.S.; Martini, Marinna A.

    1998-01-01

    An anti-fouling technique is developed for the protection of optical instruments from biofouling which leaches a bromide compound into a sample chamber and pumps new water into the chamber prior to measurement. The primary advantage of using bromide is that it is less toxic than the metal-based antifoulants. The drawback of the bromide technique is also discussed.

  14. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP.

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,.

  15. Consumer preferences for reduced packaging under economic instruments and recycling policy.

    Science.gov (United States)

    Yamaguchi, Keiko; Takeuchi, Kenji

    2016-02-01

    This study was conducted using a web-based survey and bidding game in contingent valuation method to evaluate consumer preferences for packaging with less material. Results revealed that people who live in a municipality implementing unit-based pricing of waste have a higher willingness-to-pay (WTP) for a product. Economic instruments can affect the purchase of products with reduced packaging because a higher disposal cost increases the attractiveness of source reduction. However, unit-based pricing combined with plastic separation for recycling reduces WTP. This result suggests that recycling policy weakens the effect of economic instruments on source reduction of waste. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Recent high precision surveys at PEP

    International Nuclear Information System (INIS)

    Sah, R.C.

    1980-12-01

    The task of surveying and aligning the components of PEP has provided an opportunity to develop new instruments and techniques for the purpose of high precision surveys. The new instruments are quick and easy to use, and they automatically encode survey data and read them into the memory of an on-line computer. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compares them with desired parameters, and calculates the required adjustments to beam element support stands

  17. Radiological survey results at 5 Porter Street, Beverly, Massachusetts (VB019)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1992-07-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 5 Porter Street, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples for radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Site Remedial Action Program guidelines

  18. Radiological survey results at 2 Porter Street, Beverly, Massachusetts (VB005)

    International Nuclear Information System (INIS)

    Foley, R.D.; Carrier, R.F.

    1992-08-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 2 Porter Street, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium dust from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples fore radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines

  19. Radiological survey results at 9 Porter Street, Beverly, Massachusetts (VB020)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1992-07-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 9 Porter Street, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples for radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines

  20. Developments in the use of economic instruments in OECD countries

    International Nuclear Information System (INIS)

    Opschoor, H.

    1994-01-01

    For the period 1987-1993, developments in the environmental policies of OECD countries with respect to the use of economic instruments are compared and the differences analyzed. The focus is on applications in the field of air pollution policies. The comparison is made on the basis of two surveys. To complete the descriptive part, a brief survey is also presented of currently discussed and recently introduced economic instruments. A description of economic instruments as such and a review of rationales for employing economic and financial incentives precede this analysis. The analysis shows that the use of economic instruments has indeed increased since 1987, but the development has not been spectacular. Possible explanations for this are presented. Also, some types of instrument have advanced more than others and the changes differ from one set of countries to another. Product charges (including air pollution-related ones) have become more widely used, especially in Scandinavian countries. Moreover, growing attention is being paid to the use of economic instruments at the international level. The incentive impacts of economic (and other) instruments appear to have received relatively little empirical attention, even though these are an important policy-relevant feature in instrument choice. 23 refs., 5 tabs

  1. The Hyper Suprime-Cam SSP Survey: Overview and survey design

    Science.gov (United States)

    Aihara, Hiroaki; Arimoto, Nobuo; Armstrong, Robert; Arnouts, Stéphane; Bahcall, Neta A.; Bickerton, Steven; Bosch, James; Bundy, Kevin; Capak, Peter L.; Chan, James H. H.; Chiba, Masashi; Coupon, Jean; Egami, Eiichi; Enoki, Motohiro; Finet, Francois; Fujimori, Hiroki; Fujimoto, Seiji; Furusawa, Hisanori; Furusawa, Junko; Goto, Tomotsugu; Goulding, Andy; Greco, Johnny P.; Greene, Jenny E.; Gunn, James E.; Hamana, Takashi; Harikane, Yuichi; Hashimoto, Yasuhiro; Hattori, Takashi; Hayashi, Masao; Hayashi, Yusuke; Hełminiak, Krzysztof G.; Higuchi, Ryo; Hikage, Chiaki; Ho, Paul T. P.; Hsieh, Bau-Ching; Huang, Kuiyun; Huang, Song; Ikeda, Hiroyuki; Imanishi, Masatoshi; Inoue, Akio K.; Iwasawa, Kazushi; Iwata, Ikuru; Jaelani, Anton T.; Jian, Hung-Yu; Kamata, Yukiko; Karoji, Hiroshi; Kashikawa, Nobunari; Katayama, Nobuhiko; Kawanomoto, Satoshi; Kayo, Issha; Koda, Jin; Koike, Michitaro; Kojima, Takashi; Komiyama, Yutaka; Konno, Akira; Koshida, Shintaro; Koyama, Yusei; Kusakabe, Haruka; Leauthaud, Alexie; Lee, Chien-Hsiu; Lin, Lihwai; Lin, Yen-Ting; Lupton, Robert H.; Mandelbaum, Rachel; Matsuoka, Yoshiki; Medezinski, Elinor; Mineo, Sogo; Miyama, Shoken; Miyatake, Hironao; Miyazaki, Satoshi; Momose, Rieko; More, Anupreeta; More, Surhud; Moritani, Yuki; Moriya, Takashi J.; Morokuma, Tomoki; Mukae, Shiro; Murata, Ryoma; Murayama, Hitoshi; Nagao, Tohru; Nakata, Fumiaki; Niida, Mana; Niikura, Hiroko; Nishizawa, Atsushi J.; Obuchi, Yoshiyuki; Oguri, Masamune; Oishi, Yukie; Okabe, Nobuhiro; Okamoto, Sakurako; Okura, Yuki; Ono, Yoshiaki; Onodera, Masato; Onoue, Masafusa; Osato, Ken; Ouchi, Masami; Price, Paul A.; Pyo, Tae-Soo; Sako, Masao; Sawicki, Marcin; Shibuya, Takatoshi; Shimasaku, Kazuhiro; Shimono, Atsushi; Shirasaki, Masato; Silverman, John D.; Simet, Melanie; Speagle, Joshua; Spergel, David N.; Strauss, Michael A.; Sugahara, Yuma; Sugiyama, Naoshi; Suto, Yasushi; Suyu, Sherry H.; Suzuki, Nao; Tait, Philip J.; Takada, Masahiro; Takata, Tadafumi; Tamura, Naoyuki; Tanaka, Manobu M.; Tanaka, Masaomi; Tanaka, Masayuki; Tanaka, Yoko; Terai, Tsuyoshi; Terashima, Yuichi; Toba, Yoshiki; Tominaga, Nozomu; Toshikawa, Jun; Turner, Edwin L.; Uchida, Tomohisa; Uchiyama, Hisakazu; Umetsu, Keiichi; Uraguchi, Fumihiro; Urata, Yuji; Usuda, Tomonori; Utsumi, Yousuke; Wang, Shiang-Yu; Wang, Wei-Hao; Wong, Kenneth C.; Yabe, Kiyoto; Yamada, Yoshihiko; Yamanoi, Hitomi; Yasuda, Naoki; Yeh, Sherry; Yonehara, Atsunori; Yuma, Suraphong

    2018-01-01

    Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2-m Subaru telescope on the summit of Mauna Kea in Hawaii. A team of scientists from Japan, Taiwan, and Princeton University is using HSC to carry out a 300-night multi-band imaging survey of the high-latitude sky. The survey includes three layers: the Wide layer will cover 1400 deg2 in five broad bands (grizy), with a 5 σ point-source depth of r ≈ 26. The Deep layer covers a total of 26 deg2 in four fields, going roughly a magnitude fainter, while the UltraDeep layer goes almost a magnitude fainter still in two pointings of HSC (a total of 3.5 deg2). Here we describe the instrument, the science goals of the survey, and the survey strategy and data processing. This paper serves as an introduction to a special issue of the Publications of the Astronomical Society of Japan, which includes a large number of technical and scientific papers describing results from the early phases of this survey.

  2. Polarimetric survey of main-belt asteroids. I. Results for fifty seven S-, L-, and K-type objects

    Science.gov (United States)

    Gil-Hutton, R.; Cañada-Assandri, M.

    2011-05-01

    Aims: We present the first results of a polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (Casleo), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids that belong to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties, similar to those shown by the asteroid (234) Barbara. Methods: The data were obtained with the Torino and CASPROF polarimeters at the 2.15 m telescope. The Torino polarimeter is an instrument that allows the simultaneous measurement of polarization in five different bands, and the CASPROF polarimeter is a two-hole aperture polarimeter with rapid modulation. Results: The survey began in 2003, and up to 2009 data on a sample of more than 170 asteroids were obtained. In this paper the results of 57 S-, L-, and K-type objects are presented, most of them are being polarimetrically observed for the first time. Using these data we find phase-polarization curves and polarimetric parameters for these taxonomic classes. Furthermore, we also find two candidates, (397) Vienna and (458) Hercynia, that could have a phase-polarization curve with a large inversion angle. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.Tables 1 and 2 are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?j/A+A/529/A86

  3. Impact of the Medical Faculty on Study Success in Freiburg: Results from Graduate Surveys

    Science.gov (United States)

    Biller, Silke; Boeker, Martin; Fabry, Götz; Giesler, Marianne

    2015-01-01

    Aim: Using the data from graduate surveys, this study aims to analyze which factors related to teaching and learning at the Freiburg Faculty of Medicine can influence study success. Background: Study success and the factors influencing it have long been the subject of investigation, with study success being measured in terms of easily quantifiable indicators (final grades, student satisfaction, etc.). In recent years, it has also frequently been assessed in terms of graduate competency levels. Graduate surveys are considered suitable instruments for measuring these dimensions of study success. Method: Data from three Freiburg graduate surveys conducted one and a half years after graduation were drawn upon for the analysis. Study success was operationalized using four indicators: results on the written section of the M2 exam, self-assessment of medical expertise and scientific expertise, and student satisfaction. Using multiple regression analyses, the predictive power was calculated for selected variables, also measured by the graduate surveys, for the different study success indicators. Results: It was possible to identify models that contribute slightly or moderately to the prediction of study success. The score earned on the university entrance qualification demonstrated itself to be the strongest predictor for forecasting the M2 written exam: R2 is between 0.08 and 0.22 for the three surveys. Different variables specific to degree program structure and teaching are helpful for predicting medical expertise (R2=0.04-0.32) and student satisfaction (R2=0.12-0.35). The two variables, structure and curricular sequencing of the degree program and combination of theory and practice, show themselves to be significant, sample-invariant predictors (β-weightStructure=0.21-0.58, β-weightCombination=0.27-0.56). For scientific expertise, no sample-independent predictors could be determined. Conclusion: Factors describing teaching hardly provide any assistance when

  4. Consumer perceptions of smart grid development: Results of a Hong Kong survey and policy implications

    International Nuclear Information System (INIS)

    Mah, Daphne Ngar-yin; Vleuten, Johannes Marinus van der; Hills, Peter; Tao, Julia

    2012-01-01

    Consumers have a major role to play in smart grid technologies which can be instrumental in addressing climate change and energy challenges. However, little is known about how consumers perceive, and how they might respond to the opportunities that smart grid technologies offer. This paper reports the results from a Hong Kong survey (n=505). It contributes to the literature by providing a better understanding of the perceptions and behaviour of electricity consumers about the possible deployment of smart grids. Our results indicate that Hong Kong consumers generally welcomed smart grid technologies and had a preference for energy saving, energy efficiency and renewable energy while they showed a high level of opposition to nuclear power. They displayed an interest in playing a much more informed and active role in energy decision-making, but they were sensitive to tariff increases. Motivations and barriers for consumers to support smart grid developments are also discussed. We conclude with a discussion of policy implications for effective consumer engagement. More policy attention is needed on demand-side measures, introducing institutional and regulatory changes, and modifying relationships between consumers, the government and utilities. - Highlights: ► Consumers have a major role in smart grid technologies. ► This paper reports findings of a Hong Kong survey on how consumers perceive and respond. ► Hong Kong consumers are interested in being informed and playing an active role in energy decision-making. ► Motivations and barriers are discussed. ► Policy recommendations for effective consumer engagement are suggested.

  5. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  6. Tomographic intensity mapping versus galaxy surveys: observing the Universe in H α emission with new generation instruments

    Science.gov (United States)

    Silva, B. Marta; Zaroubi, Saleem; Kooistra, Robin; Cooray, Asantha

    2018-04-01

    The H α line emission is an important probe for a number of fundamental quantities in galaxies, including their number density, star formation rate (SFR), and overall gas content. A new generation of low-resolution intensity mapping (IM) probes, e.g. SPHEREx and CDIM, will observe galaxies in H α emission over a large fraction of the sky from the local Universe till a redshift of z ˜ 6 - 10, respectively. This will also be the target line for observations by the high-resolution Euclid and WFIRST instruments in the z ˜ 0.7-2 redshift range. In this paper, we estimate the intensity and power spectra of the H α line in the z ˜ 0-5 redshift range using observed line luminosity functions (LFs), when possible, and simulations, otherwise. We estimate the significance of our predictions by accounting for the modelling uncertainties (e.g. SFR, extinction, etc.) and observational contamination. We find that IM surveys can make a statistical detection of the full H α emission between z ˜ 0.8 and 5. Moreover, we find that the high-frequency resolution and the sensitivity of the planned CDIM surveys allow for the separation of H α emission from several interloping lines. We explore ways to use the combination of these line intensities to probe galaxy properties. As expected, our study indicates that galaxy surveys will only detect bright galaxies that contribute up to a few per cent of the overall H α intensity. However, these surveys will provide important constraints on the high end of the H α LF and put strong constraints on the active galactic nucleus LF.

  7. New tools for systematic evaluation of teaching qualities of medical faculty: results of an ongoing multi-center survey.

    Directory of Open Access Journals (Sweden)

    Onyebuchi A Arah

    Full Text Available Tools for the evaluation, improvement and promotion of the teaching excellence of faculty remain elusive in residency settings. This study investigates (i the reliability and validity of the data yielded by using two new instruments for evaluating the teaching qualities of medical faculty, (ii the instruments' potential for differentiating between faculty, and (iii the number of residents' evaluations needed per faculty to reliably use the instruments.Multicenter cross-sectional survey among 546 residents and 629 medical faculty representing 29 medical (non-surgical specialty training programs in The Netherlands. Two instruments--one completed by residents and one by faculty--for measuring teaching qualities of faculty were developed. Statistical analyses included factor analysis, reliability and validity exploration using standard psychometric methods, calculation of the numbers of residents' evaluations needed per faculty to achieve reliable assessments and variance components and threshold analyses.A total of 403 (73.8% residents completed 3575 evaluations of 570 medical faculty while 494 (78.5% faculty self-evaluated. In both instruments five composite-scales of faculty teaching qualities were detected with high internal consistency and reliability: learning climate (Cronbach's alpha of 0.85 for residents' instrument, 0.71 for self-evaluation instrument, professional attitude and behavior (0.84/0.75, communication of goals (0.90/0.84, evaluation of residents (0.91/0.81, and feedback (0.91/0.85. Faculty tended to evaluate themselves higher than did the residents. Up to a third of the total variance in various teaching qualities can be attributed to between-faculty differences. Some seven residents' evaluations per faculty are needed for assessments to attain a reliability level of 0.90.The instruments for evaluating teaching qualities of medical faculty appear to yield reliable and valid data. They are feasible for use in medical residencies

  8. New tools for systematic evaluation of teaching qualities of medical faculty: results of an ongoing multi-center survey.

    Science.gov (United States)

    Arah, Onyebuchi A; Hoekstra, Joost B L; Bos, Albert P; Lombarts, Kiki M J M H

    2011-01-01

    Tools for the evaluation, improvement and promotion of the teaching excellence of faculty remain elusive in residency settings. This study investigates (i) the reliability and validity of the data yielded by using two new instruments for evaluating the teaching qualities of medical faculty, (ii) the instruments' potential for differentiating between faculty, and (iii) the number of residents' evaluations needed per faculty to reliably use the instruments. Multicenter cross-sectional survey among 546 residents and 629 medical faculty representing 29 medical (non-surgical) specialty training programs in The Netherlands. Two instruments--one completed by residents and one by faculty--for measuring teaching qualities of faculty were developed. Statistical analyses included factor analysis, reliability and validity exploration using standard psychometric methods, calculation of the numbers of residents' evaluations needed per faculty to achieve reliable assessments and variance components and threshold analyses. A total of 403 (73.8%) residents completed 3575 evaluations of 570 medical faculty while 494 (78.5%) faculty self-evaluated. In both instruments five composite-scales of faculty teaching qualities were detected with high internal consistency and reliability: learning climate (Cronbach's alpha of 0.85 for residents' instrument, 0.71 for self-evaluation instrument, professional attitude and behavior (0.84/0.75), communication of goals (0.90/0.84), evaluation of residents (0.91/0.81), and feedback (0.91/0.85). Faculty tended to evaluate themselves higher than did the residents. Up to a third of the total variance in various teaching qualities can be attributed to between-faculty differences. Some seven residents' evaluations per faculty are needed for assessments to attain a reliability level of 0.90. The instruments for evaluating teaching qualities of medical faculty appear to yield reliable and valid data. They are feasible for use in medical residencies, can

  9. Innovative Behaviour of High-Tech Internationalized Firms: Survey Results from Poland

    Directory of Open Access Journals (Sweden)

    Krzysztof Wach

    2016-09-01

    Full Text Available Objective: The aim of the article is to identify and verify the relationship between internationalization and innovativeness as well as innovative behaviour of high-tech businesses in Polish context. Research Design & Methods: A quantitative research design was employed. A survey was conducted on the sample of 263 firms operating in high-tech industries in Poland. To verify the assumed relationships statistical instruments were used, including descriptive statistics, Chi-Square test, the Kruskal-Wallis test and multivariate regression. Findings: The level of innovativeness of investigated hi-tech firms was relatively high. Results suggest that the innovativeness of a business contributes to the intensification of the internationalization process of firms operating in high-tech industries. The regression model confirms the dependence of internationalization on three innovative behaviours, such as the general evaluation of innovativeness of the firm, the pace of innovation diffusion and the number of implemented innovations. Implications & Recommendations: Polish high-tech businesses seem to be relatively well internationalized, especially in comparisons to general business population. Policy makers should continue to support innovativeness of Polish economy, but especia­lly these industries which are highly innovative. Contribution & Value Added: The research presented in the article seems to be one of the first in Poland investigating into internationalization and innovation in high-tech industries. The results are in line with the majority of empirical evidence worldwide. The preliminary link between innovation and internationalization among Polish high–tech businesses was confirmed.

  10. Initial Results from the Survey of Organizational Research Climates (SOuRCe) in the U.S. Department of Veterans Affairs Healthcare System

    Science.gov (United States)

    Martinson, Brian C.; Nelson, David; Hagel-Campbell, Emily; Mohr, David; Charns, Martin P.; Bangerter, Ann; Thrush, Carol R.; Ghilardi, Joseph R.; Bloomfield, Hanna; Owen, Richard; Wells, James A.

    2016-01-01

    Background In service to its core mission of improving the health and well-being of veterans, Veterans Affairs (VA) leadership is committed to supporting research best practices in the VA. Recognizing that the behavior of researchers is influenced by the organizational climates in which they work, efforts to assess the integrity of research climates and share such information with research leadership in VA may be one way to support research best practices. The Survey of Organizational Research Climate (SOuRCe) is the first validated survey instrument specifically designed to assess the organizational climate of research integrity in academic research organizations. The current study reports on an initiative to use the SOuRCe in VA facilities to characterize the organizational research climates and pilot test the effectiveness of using SOuRCe data as a reporting and feedback intervention tool. Methods We administered the SOuRCe using a cross-sectional, online survey, with mailed follow-up to non-responders, of research-engaged employees in the research services of a random selection of 42 VA facilities (e.g., Hospitals/Stations) believed to employ 20 or more research staff. We attained a 51% participation rate, yielding more than 5,200 usable surveys. Results We found a general consistency in organizational research climates across a variety of sub-groups in this random sample of research services in the VA. We also observed similar SOuRCe scale score means, relative rankings of these scales and their internal reliability, in this VA-based sample as we have previously documented in more traditional academic research settings. Results also showed more substantial variability in research climate scores within than between facilities in the VA research service as reflected in meaningful subgroup differences. These findings suggest that the SOuRCe is suitable as an instrument for assessing the research integrity climates in VA and that the tool has similar patterns of

  11. Results from the EROS microlensing survey

    NARCIS (Netherlands)

    Beaulieu, JP; Lamers, HJGLM; Chu, YH; Suntzeff, NB; Hesser, JE; Bohlender, DA

    1999-01-01

    We present a status report of the original EROS and the on-going EROS-2 microlensing surveys, which were created to search for dark matter in the Galactic halo via microlensing effects on LMC/SMC stars. Microlensing surveys provide long-term systematic observations of millions of stars in both

  12. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  13. Customer Apathy to Insurance in Nigeria: Survey Results ...

    African Journals Online (AJOL)

    Results of a recent survey of the Nigerian Insurance Industry reveal the underlying reasons for people's general indifference towards insurance. These include lack of communication by the industry, ignorance about insurance, doubts as to the integrity of insurance practitioners, and inability to afford the premium.

  14. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    Science.gov (United States)

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  15. Results from the 2012 drug and alcohol testing survey : [analysis brief].

    Science.gov (United States)

    2014-12-01

    This report summarizes the results of the 2012 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) who test positive for...

  16. Results from the 2015 Drug and Alcohol Testing Survey : analysis brief.

    Science.gov (United States)

    2017-06-01

    This report summarizes the results of the 2015 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  17. Results from the 2014 drug and alcohol testing survey : analysis brief.

    Science.gov (United States)

    2016-10-01

    This report summarizes the results of the 2014 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  18. Results from the 2016 Drug and Alcohol Testing Survey : Analysis Brief

    Science.gov (United States)

    2018-01-01

    This report summarizes the results of the 2016 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  19. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  20. The results of decompressive surgery and instrumented posterolateral fusion in refractory degenerative spondylolisthesis

    Directory of Open Access Journals (Sweden)

    Behtash H

    2009-02-01

    Full Text Available "nBackground: Degenerative spondylolisthesis is a common disease of the lumbar spine especially in older ones. The disease represents a challenge to the treating physician. At present, for those patients that deteriorate clinically, there are many proposed algorithms for the surgical treatment. This before and after study was undertaken to assess the surgical results of decompression and instrumented posterolateral fusion in these patients. "nMethods: The study population consisted of 23 patients who had undergone no prior surgery for degenerative spondylolisthesis on the lumbar spine. These patients were treated by decompression, bilateral posterolateral fusion, and segmental (pedicle screw instrumentation with mean follow-up of 29 months (range, 13-73 months. Finally, The clinical results were evaluated for all patients by means of an Oswestry Disability Index (ODI version 2.1, the Henderson's functional capacity, and persistence of leg symptoms, low back pain or claudication. Mann-Whitney and Chi-Square tests were used to assess the average values and comparison, respectively. "nResults: Henderson's functional capacity at the last visit session was excellent in 14 (60.9%, good in 7 (30.4%, fair in 2 (8.7% cases. ODI decreased from 72.2% (50-88% preoperatively to 14.4% (0-54% at the latest follow-up visit. A history of leg pain or claudication was correlated significantly with the amount of decline in ODI score and Henderson's functional capacity (p<0.05. "nConclusion: In spite of limited number of our patients, decompressive surgery plus instrumented posterolateral fusion is a safe, reliable, and satisfactory procedure for treating degenerative lumbar spondylolisthesis. This procedure may be done when conservative treatment was failed and psychological problems can be ruled out.

  1. A new algorithm to build bridges between two patient-reported health outcome instruments: the MOS SF-36® and the VR-12 Health Survey.

    Science.gov (United States)

    Selim, Alfredo; Rogers, William; Qian, Shirley; Rothendler, James A; Kent, Erin E; Kazis, Lewis E

    2018-04-19

    To develop bridging algorithms to score the Veterans Rand-12 (VR-12) scales for comparability to those of the SF-36® for facilitating multi-cohort studies using data from the National Cancer Institute Surveillance, Epidemiology, and End Results Program (SEER) linked to Medicare Health Outcomes Survey (MHOS), and to provide a model for minimizing non-statistical error in pooled analyses stemming from changes to survey instruments over time. Observational study of MHOS cohorts 1-12 (1998-2011). We modeled 2-year follow-up SF-36 scale scores from cohorts 1-6 based on baseline SF-36 scores, age, and gender, yielding 100 clusters using Classification and Regression Trees. Within each cluster, we averaged follow-up SF-36 scores. Using the same cluster specifications, expected follow-up SF-36 scores, based on cohorts 1-6, were computed for cohorts 7-8 (where the VR-12 was the follow-up survey). We created a new criterion validity measure, termed "extensibility," calculated from the square root of the mean square difference between expected SF-36 scale averages and observed VR-12 item score from cohorts 7-8, weighted by cluster size. VR-12 items were rescored to minimize this quantity. Extensibility of rescored VR-12 items and scales was considerably improved from the "simple" scoring method for comparability to the SF-36 scales. The algorithms are appropriate across a wide range of potential subsamples within the MHOS and provide robust application for future studies that span the SF-36 and VR-12 eras. It is possible that these surveys in a different setting outside the MHOS, especially in younger age groups, could produce somewhat different results.

  2. Radiologists' Usage of Social Media: Results of the RANSOM Survey.

    Science.gov (United States)

    Ranschaert, Erik R; Van Ooijen, Peter M A; McGinty, Geraldine B; Parizel, Paul M

    2016-08-01

    The growing use of social media is transforming the way health care professionals (HCPs) are communicating. In this changing environment, it could be useful to outline the usage of social media by radiologists in all its facets and on an international level. The main objective of the RANSOM survey was to investigate how radiologists are using social media and what is their attitude towards them. The second goal was to discern differences in tendencies among American and European radiologists. An international survey was launched on SurveyMonkey ( https://www.surveymonkey.com ) asking questions about the platforms they prefer, about the advantages, disadvantages, and risks, and about the main incentives and barriers to use social media. A total of 477 radiologists participated in the survey, of which 277 from Europe and 127 from North America. The results show that 85 % of all survey participants are using social media, mostly for a mixture of private and professional reasons. Facebook is the most popular platform for general purposes, whereas LinkedIn and Twitter are more popular for professional usage. The most important reason for not using social media is an unwillingness to mix private and professional matters. Eighty-two percent of all participants are aware of the educational opportunities offered by social media. The survey results underline the need to increase radiologists' skills in using social media efficiently and safely. There is also a need to create clear guidelines regarding the online and social media presence of radiologists to maximize the potential benefits of engaging with social media.

  3. Assessing the local windfield with instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, T.G.

    1980-10-01

    This report concerns the development and testing of a technique for the initial screening and evaluation of potential sites for wind-energy conversion systems (WECS). The methodology was developed through a realistic siting exercise. The siting exercise involved measurements of winds along the surface and winds aloft using a relatively new instrument system, the Tethered Aerodynamic Lifting Anemometer (TALA) kite; notation of ecological factors such as vegetation flagging, soil erosion and site exposure, and verification of an area best suited for wind-energy development by establishing and maintaining a wind monitoring network. The siting exercise was carried out in an approximately 100-square-mile region of the Tehachapi Mountains of Southern California. The results showed that a comprehensive site survey involving field measurements, ecological survey, and wind-monitoring can be an effective tool for preliminary evaluation of WECS sites.

  4. Psychological ownership: Development of an instrument

    Directory of Open Access Journals (Sweden)

    Chantal Olckers

    2013-10-01

    Purpose: The purpose of this study was to develop an instrument to measure psychological ownership in a South African context. Motivation for the study: It was found that previous instruments for the measurement of psychological ownership lacked the ability to grasp the extensive reach of psychological ownership. Research design, approach and method: A quantitative cross-sectional survey was conducted on a non-probability convenience sample of 713 skilled, highly-skilled and professional employees from various organisations in both the private and public sectors in South Africa. Main findings: Although a 69-item measurement instrument was developed in order to capture the proposed seven-dimensional psychological ownership construct, it became evident when analysing the data that a four-factor model comprising 35 items was suitable. Practical/managerial implications: If a sense of psychological ownership toward an organisation could be established amongst its employees by addressing the factors as measured by the South African Psychological Ownership Questionnaire, organisations could become enhanced workplaces and, as a result, sustainable performance could be promoted and staff could be retained. Contribution/value-add: The instrument for measuring psychological ownership in a South African context could serve as a diagnostic tool that would allow human resource professionals and managers to determine employees’ sense of psychological ownership regarding their organisation and to focus specifically on weak dimensional areas that could be improved.

  5. Designing and conducting survey research a comprehensive guide

    CERN Document Server

    Rea, Louis M

    2014-01-01

    The industry standard guide, updated with new ideas and SPSS analysis techniques Designing and Conducting Survey Research: A Comprehensive Guide Fourth Edition is the industry standard resource that covers all major components of the survey process, updated to include new data analysis techniques and SPSS procedures with sample data sets online. The book offers practical, actionable guidance on constructing the instrument, administrating the process, and analyzing and reporting the results, providing extensive examples and worksheets that demonstrate the appropriate use of survey and data tech

  6. Radon concentrations in Norwegian kindergartens: survey planning and preliminary results

    International Nuclear Information System (INIS)

    Birovljev, A.; Strand, T.; Heiberg, A.

    1998-01-01

    An extensive radon survey in Norwegian kindergartens and schools was started in early 1997; so far 2481 kindergartens were examined. Preliminary results of the first phase of the survey are presented in tabular and graphic form including, among others, the dependence of average radon concentration on the construction year of the kindergartens and on the age of the buildings. (A.K.)

  7. Postponement of Senescence: Results From the Survey of Health, Ageing and Retirement in Europe (SHARE)

    DEFF Research Database (Denmark)

    Juel Ahrenfeldt, Linda; Lindahl-Jacobsen, Rune; Rizzi, Silvia

    Old age mortality has been postponed to higher ages. However, the consequences of longer lives will depend on whether poor health is also being postponed. The objective of this study was to investigate secular changes in different health measures using data from the Survey of Health, Ageing and R...... in cognitive function during the last decade among middle aged and elderly Europeans....... and Retirement in Europe (SHARE), representing nine European countries. SHARE is an ongoing multi-national longitudinal survey of persons aged 50 and older. SHARE started in 2004-2005 and the latest wave was collected in 2013. Comparing individuals from countries who participated in the first wave (n=24......,192) and the latest wave (n=46,762), we found a significant improvement in cognitive function over the 8-9 year period. However, there was no difference in the proportion of limitations with activities of daily living (ADL) and instrumental activities of daily living (IADL). This study confirms improvements...

  8. Airborne In-Situ Measurements of Formaldehyde over California: First Results from the COFFEE Instrument

    Science.gov (United States)

    Marrero, Josette; St. Clair, Jason; Yates, Emma; Swanson, Andrew; Gore, Warren; Iraci, Laura; Hanisco, Thomas

    2016-04-01

    Formaldehyde (HCHO) is one of the most abundant oxygenated volatile organic compounds (VOCs) in the atmosphere, playing a role multiple atmospheric processes. Measurements of HCHO can be used to help quantify convective transport, the abundance of VOCs, and ozone production in urban environments. The Compact Formaldehyde FluorescencE Experiment (COFFEE) instrument uses Non-Resonant Laser Induced Fluorescence (NR-LIF) to detect trace concentrations of HCHO as part of the Alpha Jet Atmospheric eXperiment (AJAX) payload. Developed at NASA GSFC, COFFEE is a small, low maintenance instrument with a sensitivity of 100 pptv and a quick response time (1 sec). The COFFEE instrument has been customized to fit in an external wing pod on the Alpha Jet aircraft based at NASA ARC. The instrument can operate over a broad range of altitudes, from boundary layer to lower stratosphere, making it well suited for the Alpha Jet, which can access altitudes from the surface up to 40,000 ft. We will present results from flights performed over the Central Valley of California, including boundary layer measurements and vertical profiles in the tropospheric column. This region is of particular interest, due to its elevated levels of HCHO, revealed in satellite images, as well as its high ozone concentrations. In addition to HCHO, the AJAX payload includes measurements of atmospheric ozone, methane, and carbon dioxide. These results will be presented in conjunction with formaldehyde. Targets in the Central Valley consist of an oil field, agricultural areas, and highways, each of which can emit HCHO primarily and generate HCHO through secondary production. Formaldehyde is one of the few urban pollutants that can be measured from space. Plans to compare in-situ COFFEE data with satellite-based HCHO observations such as those from OMI (Aura) and OMPS (SuomiNPP) will also be presented.

  9. Availability and accessibility of e-books in Nigerian libraries: a survey

    African Journals Online (AJOL)

    This paper investigates availability and accessibility of e-books in Nigeria Libraries. A social survey method of research was adopted for the study and the questionnaire as a research instrument was used. A systematic random sampling technique was used to determine respondents in the survey. The result shows that ...

  10. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. V. TOWARD AN EMPIRICAL METAL-POOR MASS–LUMINOSITY RELATION

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Demarque, Pierre; Howell, Steve B.; Everett, Mark E.; Ciardi, David R.; Teske, Johanna K.; Henry, Todd J.; Winters, Jennifer G.

    2015-01-01

    In an effort to better understand the details of the stellar structure and evolution of metal-poor stars, the Gemini North telescope was used on two occasions to take speckle imaging data of a sample of known spectroscopic binary stars and other nearby stars in order to search for and resolve close companions. The observations were obtained using the Differential Speckle Survey Instrument, which takes data in two filters simultaneously. The results presented here are of 90 observations of 23 systems in which one or more companions was detected, and six stars where no companion was detected to the limit of the camera capabilities at Gemini. In the case of the binary and multiple stars, these results are then further analyzed to make first orbit determinations in five cases, and orbit refinements in four other cases. The mass information is derived, and since the systems span a range in metallicity, a study is presented that compares our results with the expected trend in total mass as derived from the most recent Yale isochrones as a function of metal abundance. These data suggest that metal-poor main-sequence stars are less massive at a given color than their solar-metallicity analogues in a manner consistent with that predicted from the theory

  11. Results of the staff survey: your priorities

    CERN Multimedia

    Staff Association

    2014-01-01

    This is the first in a series of articles which will give some details about the results of the Staff Association staff survey To know your priorities and the evolution of your concerns over the last decade we study how, in each of our latest three surveys, you chose from a list of 15 items the five most important and classified them by assigning them a priority, from the most important to the fifth most important. The list of fifteen items, and a short description, follows. Career evolution (classification, level of recruitment, advancement, promotion) Salary level Family policy (recognition of partners, allowances, school fees, kindergarten, nursery, crèche, parental leave) Health insurance Non-residence and international indemnity Annual salary adjustment (cost variation index) Contract policy (duration, recruitment, award of IC, conditions of the beginning and ending of the contract) Motivation at work (interest, team, supervision, mobility, reward scheme) Pensions (retirement, disability, o...

  12. Posttraumatic stress disorder in new mothers: results from a two-stage U.S. national survey.

    Science.gov (United States)

    Beck, Cheryl Tatano; Gable, Robert K; Sakala, Carol; Declercq, Eugene R

    2011-09-01

    Prevalence rates of women in community samples who screened positive for meeting the DSM-IV criteria for posttraumatic stress disorder after childbirth range from 1.7 to 9 percent. A positive screen indicates a high likelihood of this postpartum anxiety disorder. The objective of this analysis was to examine the results that focus on the posttraumatic stress disorder data obtained from a two-stage United States national survey conducted by Childbirth Connection: Listening to Mothers II (LTM II) and Listening to Mothers II Postpartum Survey (LTM II/PP). In the LTM II study, 1,373 women completed the survey online, and 200 mothers were interviewed by telephone. The same mothers were recontacted and asked to complete a second questionnaire 6 months later and of those, 859 women completed the online survey and 44 a telephone interview. Data obtained from three instruments are reported in this article: Posttraumatic Stress Disorder Symptom Scale-Self Report (PSS-SR), Postpartum Depression Screening Scale (PDSS), and the Patient Health Questionnaire-2 (PHQ-2). Nine percent of the sample screened positive for meeting the diagnostic criteria of posttraumatic stress disorder after childbirth as determined by responses on the PSS-SR. A total of 18 percent of women scored above the cutoff score on the PSS-SR, which indicated that they were experiencing elevated levels of posttraumatic stress symptoms. The following variables were significantly related to elevated posttraumatic stress symptoms levels: low partner support, elevated postpartum depressive symptoms, more physical problems since birth, and less health-promoting behaviors. In addition, eight variables significantly differentiated women who had elevated posttraumatic stress symptom levels from those who did not: no private health insurance, unplanned pregnancy, pressure to have an induction and epidural analgesia, planned cesarean birth, not breastfeeding as long as wanted, not exclusively breastfeeding at 1 month

  13. Development and Validation of Culture-Sensitive Physics Learning Environment Survey (CS-PLES

    Directory of Open Access Journals (Sweden)

    Marie Paz E. Morales

    2014-05-01

    Full Text Available The study combined qualitative approaches with quantitative research design to come up with a survey instrument called Culture-Sensitive Physics Learning Environment Survey (CS-PLES.This survey instrument is intended to extract the learners’ beliefs and expectations on the integration of culture and language in the teaching and learning process of physics concepts. Significant contribution of the instrument can be traced to establishing and defining the constructs and categories on how curriculum localization and context-based science learning can be developed aligned with students’ expectations and beliefs. The development process employed non-conventional processes adopted from literature which included pilot study to identify pre-deterministic constructs and specific categories for the items to be included in the survey. Data analysis included descriptive statistics and factor analysis to establish the categories or constructs of the survey instruments. Reliability measures of the instrument and its respective constructs were established for standardization. These categories were intended to aid researchers for an in-depth analysis when the instrument is administered for its purpose. The raw statistical categories were qualitatively paralleled with the pre-deterministic constructs to establish congruence of the survey tool to Instructional Congruence Framework (ICF.

  14. THE LUPUS TRANSIT SURVEY FOR HOT JUPITERS: RESULTS AND LESSONS

    International Nuclear Information System (INIS)

    Bayliss, Daniel D. R.; Sackett, Penny D.; Weldrake, David T. F.; Tingley, Brandon W.; Lewis, Karen M.

    2009-01-01

    We present the results of a deep, wide-field transit survey targeting 'Hot Jupiter' planets in the Lupus region of the Galactic plane conducted over 53 nights concentrated in two epochs separated by a year. Using the Australian National University 40-inch telescope at Siding Spring Observatory (SSO), the survey covered a 0.66 deg 2 region close to the Galactic plane (b = 11 0 ) and monitored a total of 110,372 stars (15.0 ≤ V ≤ 22.0). Using difference imaging photometry, 16,134 light curves with a photometric precision of σ < 0.025 mag were obtained. These light curves were searched for transits, and four candidates were detected that displayed low-amplitude variability consistent with a transiting giant planet. Further investigations, including spectral typing and radial velocity measurements for some candidates, revealed that of the four, one is a true planetary companion (Lupus-TR-3), two are blended systems (Lupus-TR-1 and 4), and one is a binary (Lupus-TR-2). The results of this successful survey are instructive for optimizing the observational strategy and follow-up procedure for deep searches for transiting planets, including an upcoming survey using the SkyMapper telescope at SSO.

  15. Cold vacuum chamber for diagnostics: Instrumentation and first results

    Directory of Open Access Journals (Sweden)

    S. Gerstl

    2014-10-01

    Full Text Available For a proper design of the cryogenic layout of superconducting insertion devices it is necessary to take into account the heat load from the beam to the cold beam tube. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG has been built. COLDDIAG is designed in a flexible way, to allow its installation in different light sources. In order to study the beam heat load and the influence of the cryosorbed gas layer, the instrumentation comprises temperature sensors, pressure gauges, and mass spectrometers as well as retarding field analyzers with which it is possible to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. In this paper we describe the experimental equipment, the installation of COLDDIAG in the Diamond Light Source and selected examples of the measurements performed to show the capabilities of this unique instrument.

  16. Cold vacuum chamber for diagnostics: Instrumentation and first results

    Science.gov (United States)

    Gerstl, S.; Voutta, R.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; de Jauregui, D. Saez; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Sikler, G.; Migliorati, M.; Spataro, B.

    2014-10-01

    For a proper design of the cryogenic layout of superconducting insertion devices it is necessary to take into account the heat load from the beam to the cold beam tube. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is designed in a flexible way, to allow its installation in different light sources. In order to study the beam heat load and the influence of the cryosorbed gas layer, the instrumentation comprises temperature sensors, pressure gauges, and mass spectrometers as well as retarding field analyzers with which it is possible to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. In this paper we describe the experimental equipment, the installation of COLDDIAG in the Diamond Light Source and selected examples of the measurements performed to show the capabilities of this unique instrument.

  17. Large-area Soil Moisture Surveys Using a Cosmic-ray Rover: Approaches and Results from Australia

    Science.gov (United States)

    Hawdon, A. A.; McJannet, D. L.; Renzullo, L. J.; Baker, B.; Searle, R.

    2017-12-01

    Recent improvements in satellite instrumentation has increased the resolution and frequency of soil moisture observations, and this in turn has supported the development of higher resolution land surface process models. Calibration and validation of these products is restricted by the mismatch of scales between remotely sensed and contemporary ground based observations. Although the cosmic ray neutron soil moisture probe can provide estimates soil moisture at a scale useful for the calibration and validation purposes, it is spatially limited to a single, fixed location. This scaling issue has been addressed with the development of mobile soil moisture monitoring systems that utilizes the cosmic ray neutron method, typically referred to as a `rover'. This manuscript describes a project designed to develop approaches for undertaking rover surveys to produce soil moisture estimates at scales comparable to satellite observations and land surface process models. A custom designed, trailer-mounted rover was used to conduct repeat surveys at two scales in the Mallee region of Victoria, Australia. A broad scale survey was conducted at 36 x 36 km covering an area of a standard SMAP pixel and an intensive scale survey was conducted over a 10 x 10 km portion of the broad scale survey, which is at a scale equivalent to that used for national water balance modelling. We will describe the design of the rover, the methods used for converting neutron counts into soil moisture and discuss factors controlling soil moisture variability. We found that the intensive scale rover surveys produced reliable soil moisture estimates at 1 km resolution and the broad scale at 9 km resolution. We conclude that these products are well suited for future analysis of satellite soil moisture retrievals and finer scale soil moisture models.

  18. The Chinese Family Assessment Instrument (C-FAI): Hierarchical Confirmatory Factor Analyses and Factorial Invariance

    Science.gov (United States)

    Shek, Daniel T. L.; Ma, Cecilia M. S.

    2010-01-01

    Objective: This paper examines the dimensionality and factorial invariance of the Chinese Family Assessment Instrument (C-FAI) using multigroup confirmatory factor analyses (MCFAs). Method: A total of 3,649 students responded to the C-FAI in a community survey. Results: Results showed that there are five dimensions of the C-FAI (communication,…

  19. [Controversies about instrumented surgery and pain relief in degenerative lumbar spine pain. Results of scientific evidence].

    Science.gov (United States)

    Robaina-Padrón, F J

    2007-10-01

    Investigation and development of new techniques for intrumented surgery of the spine is not free of conflicts of interest. The influence of financial forces in the development of new technologies an its immediately application to spine surgery, shows the relationship between the published results and the industry support. Even authors who have defend eagerly fusion techniques, it have been demonstrated that them are very much involved in the revision of new articles to be published and in the approval process of new spinal technologies. When we analyze the published results of spine surgery, we must bear in mind what have been call in the "American Stock and Exchange" as "the bubble of spine surgery". The scientific literature doesn't show clear evidence in the cost-benefit studies of most instrumented surgical interventions of the spine compare with the conservative treatments. It has not been yet demonstrated that fusion surgery and disc replacement are better options than the conservative treatment. It's necessary to point out that at present "there are relationships between the industry and back pain, and there is also an industry of the back pain". Nonetheless, the "market of the spine surgery" is growing up because patients are demanding solutions for their back problems. The tide of scientific evidence seams to go against the spinal fusions in the degenerative disc disease, discogenic pain and inespecific back pain. After decades of advances in this field, the results of spinal fusions are mediocre. New epidemiological studies show that "spinal fusion must be accepted as a non proved or experimental method for the treatment of back pain". The surgical literature on spinal fusion published in the last 20 years following the Cochrane's method establish that: 1- this is at least incomplete, not reliable and careless; 2- the instrumentation seems to slightly increase the fusion rate; 3- the instrumentation doesn't improve the clinical results in general, lacking

  20. Validation of an instrument for mathematics enhancement teaching efficacy of Pacific Northwest agricultural educators

    Science.gov (United States)

    Jansen, Daniel J.

    Teacher efficacy continues to be an important area of study in educational research. This study tested an instrument designed to assess the perceived efficacy of agricultural education teachers when engaged in lessons involving mathematics instruction. The study population of Oregon and Washington agricultural educators utilized in the validation of the instrument revealed important demographic findings and specific results related to teacher efficacy for the study population. An instrument was developed from the assimilation of three scales previously used and validated in efficacy research. Participants' mathematics teaching efficacy was assessed using a portion of the Mathematics Teaching Efficacy Beliefs Instrument (MTEBI), and personal mathematics efficacy was evaluated by the mathematics self-belief instrument which was derived from the Betz and Hackett's Mathematics Self-Efficacy Scale. The final scale, the Teachers' Sense of Efficacy Scale (TSES) created by Tschannen-Moran and Woolfolk Hoy, examined perceived personal teaching efficacy. Structural equation modeling was used as the statistical analyses tool to validate the instrument and examine correlations between efficacy constructs used to determine potential professional development needs of the survey population. As part of the data required for validation of the Mathematics Enhancement Teaching Efficacy instrument, demographic information defining the population of Oregon and Washington agricultural educators was obtained and reported. A hypothetical model derived from teacher efficacy literature was found to be an acceptable model to verify construct validity and determine strength of correlations between the scales that defined the instrument. The instrument produced an alpha coefficient of .905 for reliability. Both exploratory and confirmatory factor analyses were used to verify construct and discriminate validity. Specifics results related to the survey population of agricultural educators

  1. The 2003 Australian Breast Health Survey: survey design and preliminary results.

    Science.gov (United States)

    Villanueva, Elmer V; Jones, Sandra; Nehill, Caroline; Favelle, Simone; Steel, David; Iverson, Donald; Zorbas, Helen

    2008-01-14

    The Breast Health Surveys, conducted by the National Breast Cancer Centre (NBCC) in 1996 and 2003, are designed to gain insight into the knowledge, attitudes and behaviours of a nationally representative sample of Australian women on issues relevant to breast cancer. In this article, we focus on major aspects of the design and present results on respondents' knowledge about mammographic screening. The 2003 BHS surveyed English-speaking Australian women aged 30-69 without a history of breast cancer using computer-assisted telephone interviewing. Questions covered the following themes: knowledge and perceptions about incidence, mortality and risk; knowledge and behaviour regarding early detection, symptoms and diagnosis; mammographic screening; treatment; and accessibility and availability of information and services. Respondents were selected using a complex sample design involving stratification. Sample weights against Australian population benchmarks were used in all statistical analyses. Means and proportions for the entire population and by age group and area of residence were calculated. Statistical tests were conducted using a level of significance of 0.01. Of the 3,144 respondents who consented to being interviewed, 138 (4.4%) had a previous diagnosis of breast cancer and were excluded leaving 3,006 completed interviews eligible for analysis. A majority of respondents (61.1%) reported ever having had a mammogram and 29.1% identified mammography as being the best way of finding breast cancer. A majority of women (85.9%) had heard of the BreastScreen Australia (BSA) program, the national mammographic screening program providing free biennial screening mammograms, with 94.5% believing that BSA attendance was available regardless of the presence or absence of symptoms. There have been substantial gains in women's knowledge about mammographic screening over the seven years between the two surveys. The NBCC Breast Health Surveys provide a valuable picture of the

  2. SY 2008-09 Customer Satisfaction Survey Results (Full Report). DoDEA Results

    Science.gov (United States)

    Department of Defense Education Activity, 2009

    2009-01-01

    The Department of Defense Education Activity (DoDEA) Customer Satisfaction Survey is a biennial survey administered by DoDEA to parents and students to monitor DoDEA's success in meeting students' needs. The survey is administered every other year to sponsors with children in pre-kindergarten--12th grade and to students in grades 4-12. For the…

  3. SY 2010-11 Customer Satisfaction Survey Results (Full Report). DoDEA Results

    Science.gov (United States)

    Department of Defense Education Activity, 2011

    2011-01-01

    The Department of Defense Education Activity (DoDEA) Customer Satisfaction Survey is a biennial survey administered by DoDEA to parents and students to monitor DoDEA's success in meeting students' needs. The survey is administered every other year to sponsors with children in pre-kindergarten-12th grade and to students in grades 4-12. For the…

  4. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care.

    Science.gov (United States)

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables-training, self-efficacy, system quality and information quality-on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time.

  5. Musculoskeletal impairment survey in Rwanda: Design of survey tool, survey methodology, and results of the pilot study (a cross sectional survey

    Directory of Open Access Journals (Sweden)

    Simms Victoria

    2007-03-01

    Full Text Available Abstract Background Musculoskeletal impairment (MSI is an important cause of morbidity and mortality worldwide, especially in developing countries. Prevalence studies for MSI in the developing world have used varying methodologies and are seldom directly comparable. This study aimed to develop a new tool to screen for and diagnose MSI and to pilot test the methodology for a national survey in Rwanda. Methods A 7 question screening tool to identify cases of MSI was developed through literature review and discussions with healthcare professionals. To validate the tool, trained rehabilitation technicians screened 93 previously identified gold standard 'cases' and 86 'non cases'. Sensitivity, specificity and positive predictive value were calculated. A standardised examination protocol was developed to determine the aetiology and diagnosis of MSI for those who fail the screening test. For the national survey in Rwanda, multistage cluster random sampling, with probability proportional to size procedures will be used for selection of a cross-sectional, nationally representative sample of the population. Households to be surveyed will be chosen through compact segment sampling and all individuals within chosen households will be screened. A pilot survey of 680 individuals was conducted using the protocol. Results: The screening tool demonstrated 99% sensitivity and 97% specificity for MSI, and a positive predictive value of 98%. During the pilot study 468 out of 680 eligible subjects (69% were screened. 45 diagnoses were identified in 38 persons who were cases of MSI. The subjects were grouped into categories based on diagnostic subgroups of congenital (1, traumatic (17, infective (2 neurological (6 and other acquired(19. They were also separated into mild (42.1%, moderate (42.1% and severe (15.8% cases, using an operational definition derived from the World Health Organisation's International Classification of Functioning, Disability and Health

  6. Multiagency radiation survey and site investigation manual (MARSSIM): Survey design

    International Nuclear Information System (INIS)

    Abelquist, E.W.; Berger, J.D.

    1996-01-01

    This paper describes the MultiAgency Radiation Survey and Site Investigation Manual (MARSSIM) strategy for designing a final status survey. The purpose of the final status survey is to demonstrate that release criteria established by the regulatory agency have been met. Survey design begins with identification of the contaminants and determination of whether the radionuclides of concern exist in background. The decommissioned site is segregated into Class 1, Class 2, and Class 3 areas, based on contamination potential, and each area is further divided into survey units. Appropriate reference areas for indoor and outdoor background measurements are selected. Survey instrumentation and techniques are selected in order to assure that the instrumentation is capable of detecting the contamination at the derived concentration guideline level (DCGL). Survey reference systems are established and the number of survey data points is determined-with the required number of data points distributed on a triangular grid Pattern. Two suitistical tests are used to evaluate data from final status surveys. For contaminants that are b, present in background, the Wilcoxon Rank Sum test is used; for contaminants that are not present in background, the Wilcoxon Signed Rank (or Sign) test is used. The number of data points needed to satisfy these nonparametric tests is based on the contaminant DCGL value, the expected Standard deviation of the contaminant in background and in the survey unit, and the acceptable probability of making Type I and Type II decision errors. The MARSSIM also requires a reasonable level of assurance that any small areas of elevated residual radioactivity that could be significant relative to regulatory limits are not missed during the final status survey. Measurements and sampling on a specified grid size are used to obtain an adequate assurance level that small locations of elevated radioactivity will Still satisfy DCGLs-applicable to small areas

  7. Probing of Hermean Exosphere by ultraviolet spectroscopy: Instrument presentation, calibration philosophy and first lights results

    Science.gov (United States)

    Mariscal, J. F.; Rouanet, N.; Maria, J. L.; Quémerais, E.; Mine, P. O.; Zuppella, P.; Suman, M.; Nicolosi, P.; Pelizzo, M. G.; Yoshikawa, I.; Yoshioka, K.; Murakami, G.

    2017-11-01

    PHEBUS (Probing of Hermean Exosphere by Ultraviolet Spectroscopy) is a double spectrometer for the Extreme Ultraviolet range (55-155 nm) and the Far Ultraviolet range (145-315 nm) dedicated to the characterization of Mercury's exosphere composition and dynamics, and surface-exosphere connections. PHEBUS is part of the ESA BepiColombo cornerstone mission payload devoted to the study of Mercury. The BepiColombo mission consists of two spacecrafts: the Mercury Magnetospheric Orbiter (MMO) and the Mercury Planetary Orbiter (MPO) on which PHEBUS will be mounted. PHEBUS is a French-led instrument implemented in a cooperative scheme involving Japan (detectors), Russia (scanner) and Italy (ground calibration). Before launch, PHEBUS team want to perform a full absolute calibration on ground, in addition to calibrations which will be made in-flight, in order to know the instrument's response as precisely as possible. Instrument overview and calibration philosophy are introduced along with the first lights results observed by a first prototype.

  8. FIRST RESULTS FROM THE CATALINA REAL-TIME TRANSIENT SURVEY

    International Nuclear Information System (INIS)

    Drake, A. J.; Djorgovski, S. G.; Mahabal, A.; Graham, M. J.; Williams, R.; Beshore, E.; Larson, S.; Boattini, A.; Gibbs, A.; Hill, R.; Kowalski, R.; Christensen, E.; Catelan, M.

    2009-01-01

    We report on the results from the first six months of the Catalina Real-Time Transient Survey (CRTS). In order to search for optical transients (OTs) with timescales of minutes to years, the CRTS analyses data from the Catalina Sky Survey which repeatedly covers 26,000 of square degrees on the sky. The CRTS provides a public stream of transients that are bright enough to be followed up using small telescopes. Since the beginning of the survey, all CRTS transients have been made available to astronomers around the world in real time using HTML tables,RSS feeds, and VOEvents. As part of our public outreach program, the detections are now also available in Keyhole Markup Language through Google Sky. The initial discoveries include over 350 unique OTs rising more than 2 mag from past measurements. Sixty two of these are classified as supernovae (SNe), based on light curves, prior deep imaging and spectroscopic data. Seventy seven are due to cataclysmic variables (CVs; only 13 previously known), while an additional 100 transients were too infrequently sampled to distinguish between faint CVs and SNe. The remaining OTs include active galactic nucleus, blazars, high-proper-motions stars, highly variable stars (such as UV Ceti stars), and transients of an unknown nature. Our results suggest that there is a large population of SNe missed by many current SN surveys because of selection biases. These objects appear to be associated with faint host galaxies. We also discuss the unexpected discovery of white dwarf binary systems through dramatic eclipses.

  9. On the Effectiveness of the Dynamic Force Adjustment for Reducing the Scatter of Instrumented Charpy Results

    International Nuclear Information System (INIS)

    Lucon, E.

    2008-01-01

    One of the key factors for obtaining reliable instrumented Charpy results is the calibration of the instrumented striker. An interesting alternative to the conventional static calibration recommended by the standards is the Dynamic Force Adjustment (DFA), in which forces and displacements are iteratively adjusted until equality is achieved between absorbed energies calculated under the test record (Wt) and measured by the machine encoder (KV). In this study, this procedure has been applied to the instrumented data obtained by 10 international laboratories using notched and precracked Charpy specimens, in the framework of a Coordinated Research Project (CRP8) of IAEA. DFA is extremely effective in reducing the between-laboratory scatter for both general yield and maximum forces. The effect is less significant for dynamic reference temperatures measured from precracked Charpy specimens using the Master Curve procedure, but a moderate reduction of the standard deviation is anyway observed. It is shown that striker calibration is a prominent contribution to the interlaboratory variability of instrumented impact forces, particularly in the case of maximum forces.

  10. On the Effectiveness of the Dynamic Force Adjustment for Reducing the Scatter of Instrumented Charpy Results

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-09-15

    One of the key factors for obtaining reliable instrumented Charpy results is the calibration of the instrumented striker. An interesting alternative to the conventional static calibration recommended by the standards is the Dynamic Force Adjustment (DFA), in which forces and displacements are iteratively adjusted until equality is achieved between absorbed energies calculated under the test record (Wt) and measured by the machine encoder (KV). In this study, this procedure has been applied to the instrumented data obtained by 10 international laboratories using notched and precracked Charpy specimens, in the framework of a Coordinated Research Project (CRP8) of IAEA. DFA is extremely effective in reducing the between-laboratory scatter for both general yield and maximum forces. The effect is less significant for dynamic reference temperatures measured from precracked Charpy specimens using the Master Curve procedure, but a moderate reduction of the standard deviation is anyway observed. It is shown that striker calibration is a prominent contribution to the interlaboratory variability of instrumented impact forces, particularly in the case of maximum forces.

  11. A Frailty Instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE

    Directory of Open Access Journals (Sweden)

    Romero-Ortuno Roman

    2010-08-01

    Full Text Available Abstract Background A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http://www.share-project.org, a large population-based survey conducted in 2004-2005 in twelve European countries. Methods Subjects: SHARE Wave 1 respondents (17,304 females and 13,811 males. Measures: five SHARE variables approximating Fried's frailty definition. Analyses (for each gender: 1 estimation of a discreet factor (DFactor model based on the frailty variables using LatentGOLD®. A single DFactor with three ordered levels or latent classes (i.e. non-frail, pre-frail and frail was modelled; 2 the latent classes were characterised against a biopsychosocial range of Wave 1 variables; 3 the prospective mortality risk (unadjusted and age-adjusted for each frailty class was established on those subjects with known mortality status at Wave 2 (2007-2008 (11,384 females and 9,163 males; 4 two web-based calculators were created for easy retrieval of a subject's frailty class given any five measurements. Results Females: the DFactor model included 15,578 cases (standard R2 = 0.61. All five frailty indicators discriminated well (p N = 10,420; 66.9%, pre-frail (N = 4,025; 25.8%, and frail (N = 1,133; 7.3%. Relative to the non-frail class, the age-adjusted Odds Ratio (with 95% Confidence Interval for mortality at Wave 2 was 2.1 (1.4 - 3.0 in the pre-frail and 4.8 (3.1 - 7.4 in the frail. Males: 12,783 cases (standard R2 = 0.61, all frailty indicators had p N = 10,517; 82.3%, pre-frail (N = 1,871; 14.6%, and frail (N = 395; 3.1%; age-adjusted OR (95% CI for mortality: 3.0 (2.3 - 4.0 in the pre-frail, 6.9 (4.7 - 10.2 in the frail. Conclusions The SHARE Frailty Instrument has sufficient construct and

  12. On the practical use of CASE tools : results of a survey

    NARCIS (Netherlands)

    Kusters, R.J.; Wijers, G.M.; Lee, H-Y.; Reid, T.F.; Jarzabek, S.

    1993-01-01

    The results of a recent survey of experienced CASE-tool users in the Netherlands are described. The subjects of the survey were a general evaluation of the tools used, a comparison of the objectives envisaged when acquiring the tools to the objectives that were seen to be attained, selection

  13. Radiological survey results at Porter Street City Park, Beverly, Massachusetts (VB026)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1992-08-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at the Porter Street City Park, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples for radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines

  14. Results from the national hospice volunteer training survey.

    Science.gov (United States)

    Wittenberg-Lyles, Elaine; Schneider, Greg; Oliver, Debra Parker

    2010-03-01

    Although the role of volunteers is at the heart of hospice care, little is known about hospice volunteer training and volunteer activity. A survey was used to assess current training programs for hospice volunteers. Hospices were invited to participate in the study from a link on the website for the Hospice Volunteer Association and Hospice Educators Affirming Life Project. Survey results revealed that the majority of volunteer work is in patient care, with most hospice agencies requiring a minimum 12-month volunteer commitment and an average 4-hour volunteer shift per week. Volunteer training is separate from staff training, is provided by paid agency staff, and costs approximately $14,303 per year. Communication and family support are considered important curriculum topics. Revisions to current volunteer training curriculum and format are suggested.

  15. The Danish airborne gamma-ray surveying results

    Energy Technology Data Exchange (ETDEWEB)

    Hovgaard, J. [Danish Emergency Management Agency, Birkeroed (Denmark)

    1997-12-31

    The Danish Emergency Management Agency (DEMA) in co-operation with the Technical University of Denmark (TUD), Department of Automation, participated in the international exercise RESUME-95 arranged in Finland in August 1995. DEMA performed measurement with their airborne gamma-ray surveying system. Surveys were done in the three areas known as AREA I, II, III. Results from AREA II (3 km x 6 km) show that the apparent {sup 137}Cs deposition assuming a deposition profile equal to the profile in AREA I based on soil samples varies from a few 10th kBqm{sup -2} up to 110 kBqm{sup -2}. However, a detailed analysis using a new method, Noise Adjusted Singular Value Decomposition (NASVD), shows that the true variations probably are smaller and that the observed differences to some extend are due to major variations in the depth distribution of the cesium. For example agricultural areas appears to have cesium much deeper deposit than the undisturbed areas. Another interesting result is that the NASVD analysis shows that the ration of {sup 134}Cs to {sup 137}Cs is fixed and approximately 0.03 (August 1995) a number in good agreement with the expected ratio from the Chernobyl accident. No true real-time software for source detection is yet integrated in the Danish system. Results from AREA III, however, show that the implemented software for rapid post processing of data worked excellent for detection of radioactive sources. Post analysis using NASVD demonstrates that all sources except for a small {sup 137}Cs source can be localized. (au).

  16. The Danish airborne gamma-ray surveying results

    Energy Technology Data Exchange (ETDEWEB)

    Hovgaard, J [Danish Emergency Management Agency, Birkeroed (Denmark)

    1998-12-31

    The Danish Emergency Management Agency (DEMA) in co-operation with the Technical University of Denmark (TUD), Department of Automation, participated in the international exercise RESUME-95 arranged in Finland in August 1995. DEMA performed measurement with their airborne gamma-ray surveying system. Surveys were done in the three areas known as AREA I, II, III. Results from AREA II (3 km x 6 km) show that the apparent {sup 137}Cs deposition assuming a deposition profile equal to the profile in AREA I based on soil samples varies from a few 10th kBqm{sup -2} up to 110 kBqm{sup -2}. However, a detailed analysis using a new method, Noise Adjusted Singular Value Decomposition (NASVD), shows that the true variations probably are smaller and that the observed differences to some extend are due to major variations in the depth distribution of the cesium. For example agricultural areas appears to have cesium much deeper deposit than the undisturbed areas. Another interesting result is that the NASVD analysis shows that the ration of {sup 134}Cs to {sup 137}Cs is fixed and approximately 0.03 (August 1995) a number in good agreement with the expected ratio from the Chernobyl accident. No true real-time software for source detection is yet integrated in the Danish system. Results from AREA III, however, show that the implemented software for rapid post processing of data worked excellent for detection of radioactive sources. Post analysis using NASVD demonstrates that all sources except for a small {sup 137}Cs source can be localized. (au).

  17. Initial Results from the Survey of Organizational Research Climates (SOuRCe) in the U.S. Department of Veterans Affairs Healthcare System.

    Science.gov (United States)

    Martinson, Brian C; Nelson, David; Hagel-Campbell, Emily; Mohr, David; Charns, Martin P; Bangerter, Ann; Thrush, Carol R; Ghilardi, Joseph R; Bloomfield, Hanna; Owen, Richard; Wells, James A

    2016-01-01

    In service to its core mission of improving the health and well-being of veterans, Veterans Affairs (VA) leadership is committed to supporting research best practices in the VA. Recognizing that the behavior of researchers is influenced by the organizational climates in which they work, efforts to assess the integrity of research climates and share such information with research leadership in VA may be one way to support research best practices. The Survey of Organizational Research Climate (SOuRCe) is the first validated survey instrument specifically designed to assess the organizational climate of research integrity in academic research organizations. The current study reports on an initiative to use the SOuRCe in VA facilities to characterize the organizational research climates and pilot test the effectiveness of using SOuRCe data as a reporting and feedback intervention tool. We administered the SOuRCe using a cross-sectional, online survey, with mailed follow-up to non-responders, of research-engaged employees in the research services of a random selection of 42 VA facilities (e.g., Hospitals/Stations) believed to employ 20 or more research staff. We attained a 51% participation rate, yielding more than 5,200 usable surveys. We found a general consistency in organizational research climates across a variety of sub-groups in this random sample of research services in the VA. We also observed similar SOuRCe scale score means, relative rankings of these scales and their internal reliability, in this VA-based sample as we have previously documented in more traditional academic research settings. Results also showed more substantial variability in research climate scores within than between facilities in the VA research service as reflected in meaningful subgroup differences. These findings suggest that the SOuRCe is suitable as an instrument for assessing the research integrity climates in VA and that the tool has similar patterns of results that have been

  18. Initial Results from the Survey of Organizational Research Climates (SOuRCe in the U.S. Department of Veterans Affairs Healthcare System.

    Directory of Open Access Journals (Sweden)

    Brian C Martinson

    Full Text Available In service to its core mission of improving the health and well-being of veterans, Veterans Affairs (VA leadership is committed to supporting research best practices in the VA. Recognizing that the behavior of researchers is influenced by the organizational climates in which they work, efforts to assess the integrity of research climates and share such information with research leadership in VA may be one way to support research best practices. The Survey of Organizational Research Climate (SOuRCe is the first validated survey instrument specifically designed to assess the organizational climate of research integrity in academic research organizations. The current study reports on an initiative to use the SOuRCe in VA facilities to characterize the organizational research climates and pilot test the effectiveness of using SOuRCe data as a reporting and feedback intervention tool.We administered the SOuRCe using a cross-sectional, online survey, with mailed follow-up to non-responders, of research-engaged employees in the research services of a random selection of 42 VA facilities (e.g., Hospitals/Stations believed to employ 20 or more research staff. We attained a 51% participation rate, yielding more than 5,200 usable surveys.We found a general consistency in organizational research climates across a variety of sub-groups in this random sample of research services in the VA. We also observed similar SOuRCe scale score means, relative rankings of these scales and their internal reliability, in this VA-based sample as we have previously documented in more traditional academic research settings. Results also showed more substantial variability in research climate scores within than between facilities in the VA research service as reflected in meaningful subgroup differences. These findings suggest that the SOuRCe is suitable as an instrument for assessing the research integrity climates in VA and that the tool has similar patterns of results that

  19. The Design and Validation of the Colorado Learning Attitudes about Science Survey

    Science.gov (United States)

    Adams, W. K.; Perkins, K. K.; Dubson, M.; Finkelstein, N. D.; Wieman, C. E.

    2005-09-01

    The Colorado Learning Attitudes about Science Survey (CLASS) is a new instrument designed to measure various facets of student attitudes and beliefs about learning physics. This instrument extends previous work by probing additional facets of student attitudes and beliefs. It has been written to be suitably worded for students in a variety of different courses. This paper introduces the CLASS and its design and validation studies, which include analyzing results from over 2400 students, interviews and factor analyses. Methodology used to determine categories and how to analyze the robustness of categories for probing various facets of student learning are also described. This paper serves as the foundation for the results and conclusions from the analysis of our survey data.

  20. Plastic-bag radon gas monitor and survey results

    International Nuclear Information System (INIS)

    Torri, G.

    1990-01-01

    The Plastic-bag radon monitor used in the Italian National Survey is described. The choice of this radon gas sampler has been determined by the peculiarity of the italian environmental monitoring program, which is carried out by several different regional laboratories. Results obtained in the past using this radon monitoring device are also reported. (author). 8 refs, 7 figs

  1. The CASLEO Polarimetric Survey of Main Belt Asteroids: Updated results

    Science.gov (United States)

    Gil-Hutton, R.; Cellino, A.; Cañada-Assandri, M.

    2011-10-01

    We present updated results of the polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (Casleo), San Juan, Argentina, using the 2.15 m telescope and the Torino and CASPROF polarimeters. The goals of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids belonging to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties. The survey began in 2003, and data for a sample of more than 170 asteroids have been obtained, most of them having been polarimetrically observed for the first time. Using these data we find phase-polarization curves and polarimetric parameters for several taxonomic classes.

  2. Flux Gain for Next-Generation Neutron-Scattering Instruments Resulting From Improved Supermirror Performance

    International Nuclear Information System (INIS)

    Rehm, C.

    2001-01-01

    Next-generation spallation neutron source facilities will offer instruments with unprecedented capabilities through simultaneous enhancement of source power and usage of advanced optical components. The Spallation Neutron Source (SNS), already under construction at Oak Ridge National Laboratory and scheduled to be completed by 2006, will provide greater than an order of magnitude more effective source flux than current state-of-the-art facilities, including the most advanced research reactors. An additional order of magnitude gain is expected through the use of new optical devices and instrumentation concepts. Many instrument designs require supermirror (SM) neutron guides with very high critical angles for total reflection. In this contribution, they discuss how the performance of modern neutron scattering instruments depends on the efficiency of these supermirrors. They outline ideas for enhancing the performance of the SM coatings, particularly for improving the reflectivity at the position of the critical wave vector transfer. A simulation program has been developed which allows different approaches for SM designs to be studied. Possible instrument performance gains are calculated for the example of the SNS reflectometer

  3. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  4. Wide Field Radio Transient Surveys

    Science.gov (United States)

    Bower, Geoffrey

    2011-04-01

    The time domain of the radio wavelength sky has been only sparsely explored. Nevertheless, serendipitous discovery and results from limited surveys indicate that there is much to be found on timescales from nanoseconds to years and at wavelengths from meters to millimeters. These observations have revealed unexpected phenomena such as rotating radio transients and coherent pulses from brown dwarfs. Additionally, archival studies have revealed an unknown class of radio transients without radio, optical, or high-energy hosts. The new generation of centimeter-wave radio telescopes such as the Allen Telescope Array (ATA) will exploit wide fields of view and flexible digital signal processing to systematically explore radio transient parameter space, as well as lay the scientific and technical foundation for the Square Kilometer Array. Known unknowns that will be the target of future transient surveys include orphan gamma-ray burst afterglows, radio supernovae, tidally-disrupted stars, flare stars, and magnetars. While probing the variable sky, these surveys will also provide unprecedented information on the static radio sky. I will present results from three large ATA surveys (the Fly's Eye survey, the ATA Twenty CM Survey (ATATS), and the Pi GHz Survey (PiGSS)) and several small ATA transient searches. Finally, I will discuss the landscape and opportunities for future instruments at centimeter wavelengths.

  5. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  6. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  7. Radiological protection survey results about radiodiagnosis protection practices in Cuba

    International Nuclear Information System (INIS)

    Jova S, L.; Morales M, J.A.; Quevedo, J.R.; Medina, J.R.; Naranjo, A.M.; Fornet, O.M.

    1996-01-01

    In order to identify radiation protection current situation in national X-ray diagnostic practice , the State (cuban) Supervision System for Radiation and Nuclear Safety carried out in 1992 a survey which was planned for projection of future regulatory activities in this field. Survey covers the most important aspects related to radiation protection of occupationally exposed workers, patients and general population. Surveyed sample included a total of 52 X-ray units, sited in 7 dental clinics, 2 polyclinics and 13 hospitals, from 7 provinces of the country. Results showed that the organization of radiation protection in terms of personnel specially designated to carry out surveillance and control activities and level of documentation is deficient. Survey evidenced the general lack of safety and quality culture among technologists and radiologists which is mainly reflected in non regular application of basic patient protection measures (shielding, collimation, use of proper filtration among others) and non regular execution of basic quality inspection of employed radiographic systems. (authors). 4 refs., 1 fig

  8. Status of ART-XC/SRG Instrument

    Science.gov (United States)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; hide

    2014-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1', a field of view of approximately 34' and an expected energy resolution of about 10 percent at 14 keV.

  9. Gender and Participation in High School and College Instrumental Jazz Ensembles

    Science.gov (United States)

    McKeage, Kathleen M.

    2004-01-01

    This study is an examination of the relationship between gender and participation in high school and college instrumental jazz ensembles. Student demographic and attitudinal information was collected using the researcher-designed Instrumental Jazz Participation Survey (IJPS). Undergraduate college band students (N = 628) representing 15 programs…

  10. Emotional support, instrumental support, and gambling participation among Filipino Americans.

    Science.gov (United States)

    Kim, Isok; Kim, Wooksoo; Nochajski, Thomas H

    2014-08-01

    Using representative survey data of Filipino Americans in Honolulu and San Francisco (SF) (N = 2,259), we examined the roles of emotional support and instrumental support on gambling participation. With considerable difference in gambling environments between two regions, we conducted two sets of hierarchical regression analyses for Honolulu sample, which has restricted gambling laws, and SF sample, which has legal gambling environment, and compared the effects of two types of social support on gambling participation. The results indicated that emotional support was positively and instrumental support was negatively associated with gambling participation among Filipino Americans in Honolulu. However, neither type of social support was significantly associated with gambling participation among Filipino Americans living in SF. This study highlights the differing roles and effects of instrumental and emotional support on gambling where gambling is restricted. It also suggests that gambling behaviors of Filipino Americans are subject to situation- and environment-specific factors.

  11. The POKEMON Speckle Survey of Nearby M-Dwarfs

    Science.gov (United States)

    van Belle, Gerard; von Braun, Kaspar; Horch, Elliott; Clark, Catherine; DSSI Speckle Team

    2018-01-01

    The POKEMON (Pervasive Overview of Kompanions of Every M-dwarf in Our Neighborhood) survey of nearby M-dwarfs intends to inspect, at diffraction-limited resolution, every low-mass star out to 15pc, along with selected additional objects to 25pc. The primary emphasis of the survey is detection of low-mass companions to these M-dwarfs for refinement of the low-mass star multiplicity rate. The resultant catalog of M-dwarf companions will also guide immediate refinement of transit planet detection results from surveys such as TESS. POKEMON is using Lowell Observatory's 4.3-m Discovery Channel Telescope (DCT) with the Differential Speckle Survey Instrument (DSSI) speckle camera, along with the NN-Explore Exoplanet Stellar Speckle Imager (NESSI) speckle imager on 3.5-m WIYN; the survey takes advantage of the extremely rapid observing cadence rates possible with WIYN and (especially) DCT. The current status and preliminary results from the first 20+ nights of observing will be presented. Gotta observe them all!

  12. Developing instruments concerning scientific epistemic beliefs and goal orientations in learning science: a validation study

    Science.gov (United States)

    Lin, Tzung-Jin; Tsai, Chin-Chung

    2017-11-01

    The purpose of this study was to develop and validate two survey instruments to evaluate high school students' scientific epistemic beliefs and goal orientations in learning science. The initial relationships between the sampled students' scientific epistemic beliefs and goal orientations in learning science were also investigated. A final valid sample of 600 volunteer Taiwanese high school students participated in this survey by responding to the Scientific Epistemic Beliefs Instrument (SEBI) and the Goal Orientations in Learning Science Instrument (GOLSI). Through both exploratory and confirmatory factor analyses, the SEBI and GOLSI were proven to be valid and reliable for assessing the participants' scientific epistemic beliefs and goal orientations in learning science. The path analysis results indicated that, by and large, the students with more sophisticated epistemic beliefs in various dimensions such as Development of Knowledge, Justification for Knowing, and Purpose of Knowing tended to adopt both Mastery-approach and Mastery-avoidance goals. Some interesting results were also found. For example, the students tended to set a learning goal to outperform others or merely demonstrate competence (Performance-approach) if they had more informed epistemic beliefs in the dimensions of Multiplicity of Knowledge, Uncertainty of Knowledge, and Purpose of Knowing.

  13. A practical guide to surveys and questionnaires.

    Science.gov (United States)

    Slattery, Eric L; Voelker, Courtney C J; Nussenbaum, Brian; Rich, Jason T; Paniello, Randal C; Neely, J Gail

    2011-06-01

    Surveys with questionnaires play a vital role in decision and policy making in society. Within medicine, including otolaryngology, surveys with questionnaires may be the only method for gathering data on rare or unusual events. In addition, questionnaires can be developed and validated to be used as outcome measures in clinical trials and other clinical research architecture. Consequently, it is fundamentally important that such tools be properly developed and validated. Just asking questions that have not gone through rigorous design and development may be misleading and unfair at best; at worst, they can result in under- or overtreatment and unnecessary expense. Furthermore, it is important that consumers of the data produced by these instruments understand the principles of questionnaire design to interpret results in an optimal and meaningful way. This article presents a practical guide for understanding the methodologies of survey and questionnaire design, including the concepts of validity and reliability, how surveys are administered and implemented, and, finally, biases and pitfalls of surveys.

  14. The SAAS-R: A New Instrument to Assess the School Attitudes of Students with High and Low Academic Achievement in Spain

    Science.gov (United States)

    Miñano Pérez, Pablo; Costa, Juan Luis Castejón; Corbi, Raquel Gilar; Iniesta, Alejandro Veas

    2017-01-01

    We examined the psychometric properties of the School Attitude Assessment Survey-Revised in a Spanish population (n = 1,398). Confirmatory factor analysis procedures supported the instrument's five-factor structure. The results of discriminant analysis demonstrated the predictive power of the School Attitude Assessment Survey-Revised scales as…

  15. System reliability worth assessment at a midwest utility-survey results for residential customers

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, A.A.; Mielnik, T.C. [Electric System Planning, MidAmerican Energy Company, Davenport, Iowa (United States); Lawton, L.E.; Sullivan, M.J.; Katz, A. [Population Research Systems, San Francisco, CA (United States)

    2005-12-01

    This paper presents the overall results of a residential customer survey conducted in service areas of MidAmerican Energy Company, a Midwest utility. A similar survey was conducted concurrently in the industrial, commercial and institutional sectors and the survey results are presented in a companion paper. The results of this study are compared with the results of other studies performed in the high cost areas of the US east and west coasts. This is the first ever study of this nature performed for the residential customers in the US Midwest region. Methodological differences in the study design compared to coastal surveys are discussed. Customer survey costing techniques can be categorized into three main groups: contingent valuation techniques, direct costing techniques and indirect costing techniques. Most customer surveys conducted by different organizations in the last two decades used a combination of all three techniques. The selection of a technique is mainly dependent on the type of customer being surveyed. In this MidAmerican study, contingent valuation techniques and an indirect costing technique have been used, as most consequences of power outages to residential users are related to inconvenience or disruption of housekeeping and leisure activities that are intangible in nature. The major contribution of this paper is that particulars of Midwest residential customers compared to residential customers of coastal utilities are noted and customer responses on power quality issues that are important to customers are summarized. (author)

  16. Teaching Non-Beginner Programmers with App Inventor: Survey Results and Implications

    Science.gov (United States)

    Soares, Andrey; Martin, Nancy L.

    2015-01-01

    This paper reports the results of a survey with 40 students enrolled in an Android Application Development course offered during the spring semester of 2013 and 2014. The course used App Inventor to build the apps and required students to have an introduction to programming course as a prerequisite. The survey asked for demographic information and…

  17. Instruments and Taxonomy of Workplace Bullying in Health Care Organizations

    Directory of Open Access Journals (Sweden)

    Eun-Jun Park, PhD, RN

    2017-12-01

    Full Text Available Summary: Purpose: This study was aimed to evaluate the methodological issues and comprehensiveness of workplace bullying instruments and to suggest a taxonomy of psychological abuse. Methods: Nineteen instruments applied in health care organizations and 469 questionnaire items mainly regarding psychological abuse were collected through a literature review. Three researchers classified the questionnaire items according to a “taxonomy of psychological abuse in the workplace.” Results: Many instruments of workplace bullying were developed in the 2000s using a reflective measurement model, but their psychometric property was not sufficient and the measurement model is questioned. Based on the questionnaire items, the “taxonomy of psychological abuse in the workplace” was modified by adding two new subcategories (unachievable work and unfair treatment and clarifying some operational definitions. According to the modified taxonomy of 11 (subcategories, the reviewed instruments assessed 6.5 (subcategories on average. No instrument measured all (subcategories. Category 4.2 (disrespect, humiliation, and rejection of the person was measured in all instruments, followed by Categories 5 (professional discredit and denigration and 1.2 (social isolation behaviors. Conclusion: The current instruments are not comprehensive enough. It is suggested that the modified taxonomy is verified and guide more reliable and inclusive instruments in the future. Furthermore, a formative measurement model, which defines a bullying as an inventory of different types of behaviors, should be used. Keywords: aggression, bullying, hostility, mobbing, surveys and questionnaires

  18. The use of instruments of logistics and marketing in transport enterprises in lubuskie voivodeship

    Directory of Open Access Journals (Sweden)

    Agnieszka Perzyńska

    2016-09-01

    Full Text Available Background: The aim of the article is to verify the logistics and marketing instruments used in transport enterprises in Lubuskie voivodeship. The article presents the results of surveys of transport companies. Based on these studies in transport enterprises in Lubuskie, the current level of the use of logistics and marketing instruments was determined. Logistics and marketing instruments were separated to study the needs of transport companies in Lubuskie voivodeship. The choice of these instruments gave rise to a study f the possibility of using them in the implementation of business operations. From the findings it can be inferred that they are useful for the voivodeship, and that such a system can be implemented in the whole country. Methods: The study was conducted in the second half of 2014 and 140 transport enterprises in Lubuskie. Based on the research results, classifications of instruments were developed using logistics and marketing division at their levels. Results: On the basis of these findings and observations, the authors have analysed the levels of identification instruments, logistics and marketing. On this basis, it was possible to identify the instruments used by logistics and marketing in these companies. Conclusions: Based on the study of transport companies in Lubuskie voivodeship, a selection of logistics and marketing instruments were identified, along with a classification of the logistics and marketing instruments used. With the implementation of the above steps to classify the usage level of logistics and marketing instruments, the ability to match these levels to data transport companies was established.

  19. Human factors aspects of advanced instrumentation in the nuclear industry

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    An important consideration in regards to the use of advanced instrumentation in the nuclear industry is the interface between the instrumentation system and the human. A survey, oriented towards identifying the human factors aspects of digital instrumentation, was conducted at a number of United States (US) and Canadian nuclear vendors and utilities. Human factors issues, subsumed under the categories of computer-generated displays, controls, organizational support, training, and related topics were identified. 20 refs., 2 tabs

  20. Psychometric Evaluation of a New Instrument to Evaluate School Nurses' Perceptions on Concussion Care Management.

    Science.gov (United States)

    Schneider, Kathleen H

    2017-10-01

    The rate of concussions in adolescents has risen over the last decade, resulting in cognitive and emotional problems. Neurologists recommend cognitive and physical rest during the recovery period, followed by a transitional return-to-classroom protocol. The purpose of the study was to develop and test an instrument that explores the beliefs and roles of school nurses in concussion care management. The instrument was a cross-sectional descriptive survey based on the theory of planned behavior, using Qualtrics®. The psychometric properties of the instrument were assessed through exploratory factor analysis with orthogonal rotation. The reliability of the instrument was assessed for internal consistency reliability using Cronbach's α. Kaiser-Meyer-Olkin for sample adequacy was .8; Cronbach's α strong (.851).

  1. CARMENES instrument control system and operational scheduler

    Science.gov (United States)

    Garcia-Piquer, Alvaro; Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Gesa, Lluis; Morales, Juan Carlos; Pérez-Calpena, Ana; Seifert, Walter; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, José A.; Reiners, Ansgar

    2014-07-01

    visibility, sky background, required time sampling coverage) and the dynamic change of the system conditions (i.e., weather, system conditions). Off-line and on-line strategies are integrated into a single tool for a suitable transfer of the target prioritization made by the science team to the real-time schedule that will be used by the instrument operators. A suitable solution will be expected to increase the efficiency of telescope operations, which will represent an important benefit in terms of scientific return and operational costs. We present the operational scheduling tool designed for CARMENES, which is based on two algorithms combining a global and a local search: Genetic Algorithms and Hill Climbing astronomy-based heuristics, respectively. The algorithm explores a large amount of potential solutions from the vast search space and is able to identify the most efficient ones. A planning solution is considered efficient when it optimizes the objectives defined, which, in our case, are related to the reduction of the time that the telescope is not in use and the maximization of the scientific return, measured in terms of the time coverage of each target in the survey. We present the results obtained using different test cases.

  2. Indoor and Outdoor Mobile Mapping Systems for Architectural Surveys

    Science.gov (United States)

    Campi, M.; di Luggo, A.; Monaco, S.; Siconolfi, M.; Palomba, D.

    2018-05-01

    This paper presents the results of architectural surveys carried out with mobile mapping systems. The data acquired through different instruments for both indoor and outdoor surveying are analyzed and compared. The study sample shows what is required for an acquisition in a dynamic mode indicating the criteria for the creation of a georeferenced network for indoor spaces, as well as the operational processes concerning data capture, processing, and management. The differences between a dynamic and static scan have been evaluated, with a comparison being made with the aerial photogrammetric survey of the same sample.

  3. Research and Development on a Public Attitude Instrument for Stuttering

    Science.gov (United States)

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  4. Defining refractory migraine: results of the RHSIS Survey of American Headache Society members.

    Science.gov (United States)

    Schulman, Elliott A; Peterlin, B Lee; Lake, Alvin E; Lipton, Richard B; Hanlon, Alexandra; Siegel, Sherry; Levin, Morris; Goadsby, Peter J; Markley, Herbert G

    2009-04-01

    To gauge consensus regarding a proposed definition for refractory migraine proposed by Refractory Headache Special Interest Section, and where its use would be most appropriate. Headache experts have long recognized that a subgroup of headache sufferers remains refractory to treatment. Although different groups have proposed criteria to define refractory migraine, the definition remains controversial. The Refractory Headache Special Interest Section of the American Headache Society developed a definition through a consensus process, assisted by a literature review and initial membership survey. A 12-item questionnaire was distributed at the American Headache Society meeting in 2007 during a platform session and at the Refractory Headache Special Interest Section symposium. The same questionnaire was subsequently sent to all American Headache Society members via e-mail. A total of 151 responses from AHS members form the basis of this report. The survey instrument was designed using Survey Monkey. Frequencies and percentages of the survey were used to describe survey responses. American Headache Society members agreed that a definition for refractory migraine is needed (91%) that it should be added to the International Classification of Headache Disorders-2 (86%), and that refractory forms of non-migraine headache disorders should be defined (87%). Responders believed a refractory migraine definition would be of greatest value in selecting patients for clinical drug trials. The current refractory migraine definition requires a diagnosis of migraine, interference with function or quality of life despite modification of lifestyle factors, and adequate trials of acute and preventive medicines with established efficacy. The proposed criteria for the refractory migraine definition require failing 2 preventive medications to meet the threshold for failure. Although 42% of respondents agreed with the working definition of refractory migraine, 43% favored increasing the

  5. Looking Ahead: A Report on the Latest Survey Results.

    Science.gov (United States)

    Technology & Learning, 1995

    1995-01-01

    Reports on the results of a survey of software publishers and market researchers for educators that was conducted to determine development, purchasing, and upgrading plans for educational computer technology. Highlights include operating systems, including Macintosh, DOS, and Windows; equipment needs, including memory, monitors, and special…

  6. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesimaa, V.; Mattinen, M. (eds.)

    2012-03-15

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  7. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesmaa, V.; Mattinen, M. (eds.)

    2012-07-01

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  8. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  9. Plane and geodetic surveying

    CERN Document Server

    Johnson, Aylmer

    2014-01-01

    IntroductionAim And ScopeClassification Of SurveysThe Structure Of This BookGeneral Principles Of SurveyingErrorsRedundancyStiffnessAdjustmentPlanning And Record KeepingPrincipal Surveying ActivitiesEstablishing Control NetworksMappingSetting OutResectioningDeformation MonitoringAngle MeasurementThe Surveyor's CompassThe ClinometerThe Total StationMaking ObservationsChecks On Permanent AdjustmentsDistance MeasurementGeneralTape MeasurementsOptical Methods (Tachymetry)Electromagnetic Distance Measurement (EDM)Ultrasonic MethodsGNSSLevellingTheoryThe InstrumentTechniqueBookingPermanent Adjustmen

  10. Instrument specifications and geophysical records for airborne electromagnetic survey of parts of Iron, Baraga, and Dickson Counties, Michigan

    Science.gov (United States)

    Heran, William D.; Smith, Bruce D.

    1980-01-01

    The data presented herein is from an airborne electromagnetic INPUT* survey conducted by Geoterrex Limited of Canada for the U.S. Geological Survey. The survey area is located in the central part of the Upper Peninsula of Michigan, within parts of Iron, Baraga, and Dickinson Counties. The general area covered is between 46°00' and 46°30' latitude and 88°00' and 88°30' longitude (fig. 1).The INPUT survey was flown as part of a U.S. Geological Survey CUSMAP (Conterminous United States Mineral Appraisal Program) project focusing on the Iron River 2° quadrangle. The survey was flown in order to provide geophysical information which will aid in an integrated geological assessment of mineral potentials of this part of the Iron River 2° quadrangle. The flight line spacing was chosen to maximize the areal coverage without a loss of resolution of major lithologic and structural features.East-west flight lines were flown 400 feet above ground at 1/2 mile intervals. Aerial photos were used for navigation, and the flight path was recorded on continuous-strip film. A continuously recording total field ground magnetic station was used to monitor variations in the Earth's magnetic field. One north-south line was flown to provide a tie for the magnetic data, which was recorded simultaneously with the electromagnetic data by a sensor mounted in the tail of the aircraft. This report is one of two open-file reports. The map in the other report Heran and Smith (1980) shows locations of the fiducial points, the flight lines, preliminary locations of anomalies and conductive zones; all plotted on an air photomosaic. The latitude and longitude ticks marked on this map are only approximate due to distortion in air photos used to recover the flight line position. This map is preliminary and is not to be considered a final interpretation. The present report contains a description of the instrument specifications, a copy of the ground station magnetic data, and a record of the

  11. Market survey results for alternate sensor communications

    International Nuclear Information System (INIS)

    Rivas, R.R.; White, K.R.; Turnage, L.C.

    1996-02-01

    This document presents the results of a system analysis and market survey of commercially available alarm communication systems for potential use as an alternate sensor communication system. Only those systems that report alarm/sensor information to a central control panel were considered. The communication systems surveyed include wireless radio frequency (RF) systems, spread spectrum systems, fiber optic systems, twisted pair/copper wire, cellular systems, and other types of communication equipment. All systems are commercially available, and most information was obtained by telephone conversations with the manufacturer, personal interviews at security conferences, and countless reviews of the manufacturers' data sheets. Many systems were identified, but only those that met a minimum set of system requirements were included. Other systems that appeared to be applicable usually did not provide adequate data encryption or could not interface directly to the system. While such features could be incorporated using additional hardware, doing so would make the system more expensive and conflict with the idea of purchasing a single unit that meets the minimum set of requirements. Several systems greatly exceed the scope of this project and utilizing such systems would mean investing in more capacity than is really needed

  12. Results of nuclear security culture survey on personnel at nuclear power plants

    International Nuclear Information System (INIS)

    Yoo, Hosik; Lee, Jeong-Ho

    2015-01-01

    Highlights: • A new surveying questionnaire for evaluating the security awareness of personnel was developed. • The developed surveying tools consist of four categories and 44 questions in total. • The surveying tools developed in this study can be used in other countries. - Abstract: A survey to evaluate awareness of the nuclear security culture of personnel at nuclear facilities was developed. The survey was made up of a series of questionnaires that were divided into four categories, beliefs and attitude, operating systems, leadership behaviors and staff behaviors. Each category contained six to 16 questions. The category on beliefs and attitude was composed of questions that asked plant workers on how much consideration facility personnel give to issues of security when doing his/her work. The section pertaining to operating systems for nuclear security consisted of questions on guidance documents, information security, and education and training. The questions on leadership behaviors were separated into two parts, one for managers and another for staff. These include questions relating to communication between management and staff, surveillance work related to nuclear security and the sharing of information. The last category of questions concerned staff behaviors. It consisted of questions on knowledge, procedures and implementation related to nuclear security. A survey was conducted on 858 people who worked at nuclear power plants using the questionnaire that was developed in this study. The survey was performed between October 7 to 17, 2014. The survey results were collected and analyzed. A numerical value was given to each question, so that the results of the survey were represented as a score. The data revealed that awareness of the nuclear security culture increased with age. This increase stopped when staff members entered their 50s. It is believed that a person in his/her 50s has a greater degree of experience and passion for their work than

  13. Radiological survey results at 4400 Piehl Road, Ottawa Lake, Michigan

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1993-04-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 4400 Piehl Road in Ottawa Lake, Michigan. The survey was performed in September, 1992. The purpose of the survey was to determine if materials containing uranium from work performed under government contract at the former Baker Brothers facility in Toledo, Ohio had been transported off-site to this neighboring area. The radiological survey included surface gamma scans indoors and outdoors, alpha and beta scans inside the house and attached garage, beta-gamma scans of the hard surfaces outside, and the collection of soil, water, and dust samples for radionuclide analyses. Results of the survey demonstrated that the majority of the measurements on the property were within DOE guidelines. However, the presence of isolated spots of uranium contamination were found in two areas where materials were allegedly transported to the property from the former Baker Brothers site. Uranium uptake by persons on the property by ingestion is fairly unlikely, but inhalation is a possibility. Based on these findings, it is recommended that the residential property at 4400 Piehl Road in Ottawa Lake, Michigan be considered for inclusion under FUSRAP

  14. Ethical Considerations for Data Collection Using Surveys.

    Science.gov (United States)

    Hammer, Marilyn J

    2017-03-01

    Surveys are widely used instruments to collect research data. Although surveys may appear relatively benign and easily unlinked to participants, considerations for the ethical conduct of research with surveys are important. Maintaining scientific rigor is essential. This article explores ethical tenets in relation to informed consent and scientific consent when using surveys.

  15. Radiological survey results at 1 Shady Lane, Lodi, New Jersey (LJ095)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1995-07-01

    The US Department of Energy (DOE) conducted remedial action at the Stepan property in Maywood, New Jersey and several vicinity properties in Lodi, New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Maywood Interim Storage Site (MISS), adjacent to the former Maywood Chemical Works facility. The property at One Shady Lane, Lodi, New Jersey was not one of these vicinity properties but was surveyed by DOE at the request of the owner. At the request of DOE, a team from Oak Ridge National Laboratory conducted a radiological survey at this property. The purpose of the survey, conducted in November 1994, was to confirm whether remedial actions were to be performed on the property in order to be in compliance with the identified Guidelines. The radiological survey included surface gamma scans and gamma readings at 1 meter, and the collection of soil samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at One Shady Lane, Lodi, New Jersey, were comparable to background levels in the area, and well within the limits prescribed by DOE radiological guidelines. Based on the results of the radiological survey data, this property does not meet guidelines for inclusion under FUSRAP

  16. Application of microearthquake surveys in nuclear power plant siting

    International Nuclear Information System (INIS)

    1985-06-01

    Earthquakes of magnitude less than 3 are generally referred to as microearthquakes. After an overview of the use of microearthquake survey in decisions related to the siting of nuclear power plants, the main aspects of a microearthquake survey network are discussed. The use of microearthquake surveys in investigating problems related to near-field (floating) earthquakes is also discussed. The discussion is centered on the practical application of such a survey leading from objectives and limitations over to planning, instrumentation, operation, maintenance, processing of the data, and interpretation and reporting of the results. An appendix entitled Earthquake Magnitude gives useful background information for definitions of different types of magnitude and their calculation using the records from microearthquake surveys

  17. ICA Communication Audit Survey Instrument: 1977 Organizational Norms.

    Science.gov (United States)

    Goldhaber, Gerald M.; And Others

    Section one of this paper describes the history and development of the "communicaton audit," a system for assessing communication effectiveness in organizations, by the International Communication Association. Section two describes the 16 audits conducted so far and the overall demographic characteristics of the current survey data bank.…

  18. THE TIME DOMAIN SPECTROSCOPIC SURVEY: VARIABLE SELECTION AND ANTICIPATED RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Morganson, Eric; Green, Paul J. [Harvard Smithsonian Center for Astrophysics, 60 Garden St, Cambridge, MA 02138 (United States); Anderson, Scott F.; Ruan, John J. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Myers, Adam D. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Eracleous, Michael; Brandt, William Nielsen [Department of Astronomy and Astrophysics, 525 Davey Laboratory, The Pennsylvania State University, University Park, PA 16802 (United States); Kelly, Brandon [Department of Physics, Broida Hall, University of California, Santa Barbara, CA 93106-9530 (United States); Badenes, Carlos [Department of Physics and Astronomy and Pittsburgh Particle Physics, Astrophysics and Cosmology Center (PITT PACC), University of Pittsburgh, 3941 O’Hara St, Pittsburgh, PA 15260 (United States); Bañados, Eduardo [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanton, Michael R. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Bershady, Matthew A. [Department of Astronomy, University of Wisconsin, 475 N. Charter St., Madison, WI 53706 (United States); Borissova, Jura [Instituto de Física y Astronomía, Universidad de Valparaíso, Av. Gran Bretaña 1111, Playa Ancha, Casilla 5030, and Millennium Institute of Astrophysics (MAS), Santiago (Chile); Burgett, William S. [GMTO Corp, Suite 300, 251 S. Lake Ave, Pasadena, CA 91101 (United States); Chambers, Kenneth, E-mail: emorganson@cfa.harvard.edu [Institute for Astronomy, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); and others

    2015-06-20

    We present the selection algorithm and anticipated results for the Time Domain Spectroscopic Survey (TDSS). TDSS is an Sloan Digital Sky Survey (SDSS)-IV Extended Baryon Oscillation Spectroscopic Survey (eBOSS) subproject that will provide initial identification spectra of approximately 220,000 luminosity-variable objects (variable stars and active galactic nuclei across 7500 deg{sup 2} selected from a combination of SDSS and multi-epoch Pan-STARRS1 photometry. TDSS will be the largest spectroscopic survey to explicitly target variable objects, avoiding pre-selection on the basis of colors or detailed modeling of specific variability characteristics. Kernel Density Estimate analysis of our target population performed on SDSS Stripe 82 data suggests our target sample will be 95% pure (meaning 95% of objects we select have genuine luminosity variability of a few magnitudes or more). Our final spectroscopic sample will contain roughly 135,000 quasars and 85,000 stellar variables, approximately 4000 of which will be RR Lyrae stars which may be used as outer Milky Way probes. The variability-selected quasar population has a smoother redshift distribution than a color-selected sample, and variability measurements similar to those we develop here may be used to make more uniform quasar samples in large surveys. The stellar variable targets are distributed fairly uniformly across color space, indicating that TDSS will obtain spectra for a wide variety of stellar variables including pulsating variables, stars with significant chromospheric activity, cataclysmic variables, and eclipsing binaries. TDSS will serve as a pathfinder mission to identify and characterize the multitude of variable objects that will be detected photometrically in even larger variability surveys such as Large Synoptic Survey Telescope.

  19. SSL Adoption by Museums: Survey Results, Analysis, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, T. E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Druzik, J. R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Miller, N. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-11-01

    DOE Solid-State Lighting GATEWAY report that summarizes the results of a survey of the museum community regarding conversions to SSL in museums. Responses provided real-world insight into how LEDs are being incorporated into museums, and what successes and hurdles have been encountered in the process.

  20. Vibration instrumentation of the tubes of the Paluel 1 steam generator no.4. Results of tests

    International Nuclear Information System (INIS)

    Gay, N.; Campistron, R.; Launay, J.

    1985-06-01

    This report gives an overview of the instrumentation and of the measuring unit. Then the different tests carried out as also their exploitation are presented. The results are presented in the lasp part [fr

  1. The VLA Sky Survey (VLASS): Overview and First Results

    Science.gov (United States)

    Myers, Steven T.; VLASS Survey Team, Survey Science Group (SSG)

    2018-01-01

    VLASS team.In this presentation we describe the science goals, survey design, and technical implementation for the VLASS, and highlight results from the Pilot and the first epoch observations taken so far.

  2. Efficiency of lung ventilation for people performing wind instruments.

    Science.gov (United States)

    Brzęk, Anna; Famuła, Anna; Kowalczyk, Anna; Plinta, Ryszard

    Wind instruments musicians are particularly prone to excessive respiratory efforts. Prolonged wind instruments performing may lead to changes in respiratory tracts and thus to respiratory muscles overload. It may result in decreasing lung tissue pliability and, as a consequence, in emphysema. Aim of the research has been to describe basic spirometric parameters for wind players and causes of potential changes. Slow and forced spirometry with the use of Micro Lab Viasys (Micro Medical, Great Britain) was conducted on 31 wind musicians (group A). A survey concerning playing time and frequency, weight of instruments, and education on diaphragmatic breathing was conducted. The control group included 34 healthy persons at similar age (group B). The results were statistically described using Excel and Statistica programmes. The respiratory parameters were within the range of physiological norms and forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC) exceeded in both groups the values of 100%. Forced vital capacity and expiratory vital capacity (EVC) values were significantly lower in the group of musicians than in the control group (p wind instrument. Spirometric parameters relative to standards may prove a good respiratory capacity. Peak expiratory flow (PEF) and FEV1 may indicate that a proper technique of respiration during performance was acquired. The length of time when performing wind instrument may influence parameters of dynamic spirometry. Med Pr 2016;67(4):427-433. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. PAL-XFEL soft X-ray scientific instruments and X-ray optics: First commissioning results

    Science.gov (United States)

    Park, Sang Han; Kim, Minseok; Min, Changi-Ki; Eom, Intae; Nam, Inhyuk; Lee, Heung-Soo; Kang, Heung-Sik; Kim, Hyeong-Do; Jang, Ho Young; Kim, Seonghan; Hwang, Sun-min; Park, Gi-Soo; Park, Jaehun; Koo, Tae-Yeong; Kwon, Soonnam

    2018-05-01

    We report an overview of soft X-ray scientific instruments and X-ray optics at the free electron laser (FEL) of the Pohang Accelerator Laboratory, with selected first-commissioning results. The FEL exhibited a pulse energy of 200 μJ/pulse, a pulse width of power of 10 500 was achieved. The estimated total time resolution between optical laser and X-ray pulses was <270 fs. A resonant inelastic X-ray scattering spectrometer was set up; its commissioning results are also reported.

  4. Yoga in Australia: Results of a national survey

    Directory of Open Access Journals (Sweden)

    Stephen Penman

    2012-01-01

    Full Text Available Introduction: The therapeutic benefits of yoga and meditation are well documented, yet little is known about the practice of yoga in Australia or elsewhere, whether as a physical activity, a form of therapy, a spiritual path or a lifestyle. Materials and Methods: To investigate the practice of yoga in Australia, a national survey of yoga practitioners was conducted utilizing a comprehensive web-based questionnaire. Respondents were self-selecting to participate. A total of 3,892 respondents completed the survey. Sixty overseas respondents and 1265 yoga teachers (to be reported separately were excluded, leaving 2,567 yoga practitioner respondents. Results: The typical yoga survey respondent was a 41-year-old, tertiary educated, employed, health-conscious female (85% women. Asana (postures and vinyasa (sequences of postures represented 61% of the time spent practicing, with the other 39% devoted to the gentler practices of relaxation, pranayama (breathing techniques, meditation and instruction. Respondents commonly started practicing yoga for health and fitness but often continued practicing for stress management. One in five respondents practiced yoga for a specific health or medical reason which was seen to be improved by yoga practice. Of these, more people used yoga for stress management and anxiety than back, neck or shoulder problems, suggesting that mental health may be the primary health-related motivation for practicing yoga. Healthy lifestyle choices were seen to be more prevalent in respondents with more years of practice. Yoga-related injuries occurring under supervision in the previous 12 months were low at 2.4% of respondents. Conclusions: Yoga practice was seen to assist in the management of specific health issues and medical conditions. Regular yoga practice may also exert a healthy lifestyle effect including vegetarianism, non-smoking, reduced alcohol consumption, increased exercise and reduced stress with resulting cost benefits

  5. The relevance of surveying content in mining engineering education

    African Journals Online (AJOL)

    Tomi Oshokoya

    The paper will highlight the surveying content that is relevant to the mining engineering ... This article attempts to answer the question as to what ... mechanical and electrical engineering, surveying, marketing and financial .... an overview of what surveying is, its principles, surveying instrumentation and surveying.

  6. Assessment of instruments in facilitating investment in off-grid renewable energy projects

    International Nuclear Information System (INIS)

    Shi, Xunpeng; Liu, Xiying; Yao, Lixia

    2016-01-01

    Renewable off-grid solution plays a critical role in supporting rural electrification. However, off-grid Renewable Energy (OGRE) project financing faces significant challenges due to limited financing access, low affordability of consumers, high transactions costs and etc. Various supporting instruments have been implemented to facilitate OGRE investment. This study assesses the effectiveness of those instruments with a framework consists of three dimensions: feasibility, sustainability and replicability. The weights of each dimension in the framework and the scores of each instrument are assessed by expert surveys based on the Delphi method. It is suggested that all the three dimensions should be taken into consideration while assessing the instruments, among which feasibility and sustainability are considered as the most important dimensions in the assessment framework. Furthermore, the top-5 most effective instruments in facilitating OGRE investment are local engagement in operation and maintenance, loan guarantee, start-up grant, end user financing, and concessional finance. Developing countries that need to increase electrification, such as most of the ASEAN member states, could use these top scored instruments despite of their limited amount of public finance. - Highlights: •Assess the effectiveness of instruments for promoting financing for OGRE projects. •A three-dimension assessment framework: feasibility, sustainability, replicability. •Use online surveys and the Delphi method to collect experts’ assessment. •The most effective instruments: local engagement, loan guarantee, and start-up grant.

  7. Non-governmental organizations assisting victims of crime in Belgrade: Survey results

    Directory of Open Access Journals (Sweden)

    Milivojević Sanja K.

    2003-01-01

    Full Text Available This paper presents the results of survey regarding non-governmental organizations assisting victims of crime in Belgrade. The survey was completed at the end of 2002 for purposes of establishing a Victim Support Service in Serbia. In introduction authors give a short review of victim support services development in the World and the region, explaining the need for such service in Serbia, the subject and the aim of the article as well as the purpose of the survey. Second part of the paper contains the sample, methodology and the aim of the interview with NGO representatives. In the third section authors present the analysis of the survey data. Finally, in conclusion authors summarize the data and observed problems, suggestions for possible solution and directions of future development of services and organizations assisting victims of crime in Serbia.

  8. Instrumentation for medical diagnosis and research with radionuclides in the developing countries. Progress report, June 1, 1977--May 31, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, R.A.

    1978-07-01

    This project seeks to bring about a more effective use of nuclear instruments in medical applications of radionuclides in developing countries by facilitating selection of appropriate applications, by stimulating the design of instruments capable of performing these applications satisfactorily under the conditions prevailing, and by encouraging improved maintenance. A pilot cost-effectiveness analysis of nuclear medicine applications has been completed, suggesting two topics for further investigation and demonstrating that such analyses can yield useful insights. In the realm of instrument design, we have further developed our prototype well scintillation counter, provided three such instruments for tests in the field, and encouraged its production by others. In addition, we have examined design issues for liquid scintillation counters, radiorespirometry counting devices, whole-body counters, and electrical power supplies. We have completed a survey of maintenance in 8 countries in Southeast Asia and are analyzing the results. Preparations are underway for surveys in three further regions.

  9. Relationship between colorimetric (instrumental) evaluation and consumer-defined beef colour acceptability.

    Science.gov (United States)

    Holman, Benjamin W B; Mao, Yanwei; Coombs, Cassius E O; van de Ven, Remy J; Hopkins, David L

    2016-11-01

    The relationship between instrumental colorimetric values (L*, a*, b*, the ratio of reflectance at 630nm and 580nm) and consumer perception of acceptable beef colour was evaluated using a web-based survey and standardised photographs of beef m. longissimus lumborum with known colorimetrics. Only L* and b* were found to relate to average consumer opinions of beef colour acceptability. Respondent nationality was also identified as a source of variation in beef colour acceptability score. Although this is a preliminary study with the findings necessitating additional investigation, these results suggest L* and b* as candidates for developing instrumental thresholds for consumer beef colour expectations. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  10. High risk behaviour near OPG dams and power stations : results from two surveys

    Energy Technology Data Exchange (ETDEWEB)

    Giesbrecht, N.; Schmidt, R.; Ialomiteanu, A. [Centre for Addiction and Mental Health, Toronto, ON (Canada)

    2009-07-01

    High risk behaviour near dams is not uncommon. This presentation discussed the results from 2 surveys on high risk behaviour near dams and power stations operated by Ontario Power Generation (OPG). The main components of the project were presented, with particular reference to analyses of recent literature on high-risk behaviour; interviews with OPG managers and staff in 4 regions; main survey of respondents from 4 regions; follow-up interviews with high-risk respondents; interviews with community members and contacts from recreational associations; and recommendations. Specific questions and results were provided from each survey. From the first survey, the characteristics of respondents that used OPG sites for recreation were identified. One hundred high risk respondents completed a follow-up interview. The survey showed that although high-risk behaviour is not uncommon, the main reason people use the facilities are for recreation and relaxation, and not for thrill seeking purposes. Recommendations stemming from the surveys included the need for definition of boundaries and delivery of messages via children, recreational associations, and law enforcement personnel. tabs., figs.

  11. Instruments for radiation measurement in biosciences. Series 3. radioluminography. 1. Results of questionnaires to the scientists using radioluminographic techniques

    International Nuclear Information System (INIS)

    Kurihara, Norio; Nakajima, Eiichi; Takahashi, Sentaro

    1998-01-01

    Radioluminography (RLG) is a method to detect radioactivity with its photostimulated luminescence phenomenon. This paper describes major results of questionnaires to the scientists using RLG technique which was performed by the technical subcommittee for research instruments for isotope tracer of Life Science Section, Japan Radioisotope Association. The main purpose was to find the advantage and problems of RLG recognized by users. Questionnaires were sent to 271 users and 101 answers were obtained from pharmaceutical companies, universities and other public research facilities. RLG was found mainly used in gel electrophoresis in the molecular biology field, thin layer chromatography and quantitative whole body autoradiography. RLG technology itself of the instrument, imaging plate and standard usage was found to be in progress as well. Problems were those on the fundamental handling (e.g., ROI definition), on instruments, on quantitativeness, on different nuclides, on value for formal data and on radiation control. The major instrument manufacturers were Fuji Film Co., BioRad Co. and Molecular Dynamics Co. Results of the questionnaire will be published in more detailed form in future. (K.H.)

  12. Results of the PERI survey of SciDAC applications

    International Nuclear Information System (INIS)

    Supinski, Bronis R de; Hollingworth, Jeffrey K; Moore, Shirley; Worley, Patrick H

    2007-01-01

    The Performance Engineering Research Institute (PERI) project focuses on achieving superior performance for Scientific Discovery through Advanced Computing (SciDAC) applications on leadership class machines through cutting-edge research in performance modeling and automated performance tuning. This focus requires coordinated activities to engage SciDAC application teams. The initial application engagement activity was a survey of these teams to determine their performance goals, the criticality of those goals, current performance of their applications, application characteristics relevant to performance and their plans for future optimization. Using a web-based questionnaire, PERI researchers have worked with application developers to provide this information for over twenty-five applications. This paper describes the initial analysis of the application characteristics and performance goals, as well as current and future application engagement activities driven by these results. While the survey was conducted primarily to meet PERI needs, the results represent a snapshot of the state of SciDAC code development and may be of use to the DOE community at large. Overall, the results show that SciDAC application teams are engaged in significant new code development, which will require flexible performance optimization techniques that can improve performance as the applications evolve

  13. Results of evaluation of quality control measurement instrument of x-ray diagnostic equipment by non-invasive method

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alvin W.

    1996-01-01

    This work shows the results of the tests realized on Santa Rita Hospital (Porto Alegre), using a non invasive quality control measurement instrument, developed in this University for fast measurement of essential parameters of X-rays diagnostic equipment. In the tests we used a diagnostics Siemens X ray, model Heliofos 4E as our standard equipment. The linearity test of sensor probe and the exposure rate calibration was performed, with a Palmer Dosimeter. For the kVp and exposure time we used a RTI commercial instrument. (author)

  14. Results of quality control surveys of radioimmunological determinations of thyrotropin in newborns

    International Nuclear Information System (INIS)

    Roehle, G.; Kruse, R.; Voigt, U.; Torresani, T.

    1983-01-01

    Within the quality control scheme of the Deutsche Gesellschaft fuer Klinische Chemie, seven quality control surveys of thyrotropin (TSH) determinations in blood dried on filter paper have been carried out since 1980. Ninety-six screening laboratories from 12 European countries took part in these surveys. In a single survey each participant usually analysed four different samples; each of these consisted of three spots of dried blood spiked with defined amounts of thyrotropin. For the evaluations of the surveys the participants were asked to give information about their analytical results, and from these, their diagnostic classifications. The medians of the analytical results correlated well with the given thyrotropin concentrations, but the individual estimations from different laboratories varied greatly. Major discrepancies of classification were also apparent, both in the given thyrotropin concentrations and in the individual estimations. Two special collaborative studies with nine selected laboratories showed on the one hand that analysis of the largest possible part of the dried blood sample can help to optimize the precision of the results; on the other hand, considerable drawbacks related to the reagents and the methods were sometimes observed. (orig.) [de

  15. An intelligent instrument for measuring the dynamic parameters of groundwater

    International Nuclear Information System (INIS)

    Du Guoping

    2002-01-01

    An intelligent instrument was developed for measuring direction and velocity of the groundwater, permeability coefficient, hydraulic transmitting coefficient, static level, hydraulic gradient and flow direction of each layer. The instrument can be widely applied for detecting seepage of abutment and river bank, exploitation of groundwater, conservation of water and soil, water surging in mine, survey of groundwater resource and environment protection etc

  16. A Life in the Universe Survey

    Science.gov (United States)

    LoPresto, Michael C.; Hubble-Zdanowski, Jennifer

    2012-01-01

    The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…

  17. The effect of mode and context on survey results: Analysis of data from the Health Survey for England 2006 and the Boost Survey for London

    Directory of Open Access Journals (Sweden)

    Roth Marilyn A

    2010-09-01

    Full Text Available Abstract Background Health-related data at local level could be provided by supplementing national health surveys with local boosts. Self-completion surveys are less costly than interviews, enabling larger samples to be achieved for a given cost. However, even when the same questions are asked with the same wording, responses to survey questions may vary by mode of data collection. These measurement differences need to be investigated further. Methods The Health Survey for England in London ('Core' and a London Boost survey ('Boost' used identical sampling strategies but different modes of data collection. Some data were collected by face-to-face interview in the Core and by self-completion in the Boost; other data were collected by self-completion questionnaire in both, but the context differed. Results were compared by mode of data collection using two approaches. The first examined differences in results that remained after adjusting the samples for differences in response. The second compared results after using propensity score matching to reduce any differences in sample composition. Results There were no significant differences between the two samples for prevalence of some variables including long-term illness, limiting long-term illness, current rates of smoking, whether participants drank alcohol, and how often they usually drank. However, there were a number of differences, some quite large, between some key measures including: general health, GHQ12 score, portions of fruit and vegetables consumed, levels of physical activity, and, to a lesser extent, smoking consumption, the number of alcohol units reported consumed on the heaviest day of drinking in the last week and perceived social support (among women only. Conclusion Survey mode and context can both affect the responses given. The effect is largest for complex question modules but was also seen for identical self-completion questions. Some data collected by interview and self

  18. Bolivia 1998: results from the Demographic and Health Survey.

    Science.gov (United States)

    2000-09-01

    This document presents the results of the Bolivia Demographic and Health Survey (DHS), or Encuesta Nacional de Demografia y Salud 1998, conducted by the Instituto Nacional de Estadistica, La Paz, Bolivia, within the framework of the DHS Program of Macro International. Data were collected from 12,109 households and complete interviews were conducted with 11,187 women aged 15-49. A male survey was also conducted, which collected data from 3780 men aged 15-64. The information collected include the following: 1) general characteristics of the population, 2) fertility, 3) fertility preferences, 4) current contraceptive use, 5) contraception, 6) marital and contraceptive status, 7) postpartum variables, 8) infant mortality, 9) health: disease prevention and treatment, and 10) nutritional status: anthropometric measures.

  19. Policy Instruments to Improve Energy Performance of Existing Owner Occupied Dwellings

    Directory of Open Access Journals (Sweden)

    Lorraine Colette Murphy

    2016-11-01

    complete range of national instruments available at the time of the survey were studied to present a complete picture. A more detailed description of the methodologies adopted is presented below. Methodology An aim of research was to offer qualified accounts and a deeper analysis of how instruments for energy performance improvement in existing dwellings function. Research components focused on both individual instruments and combinations using a triangulation of methods and sources: expert interviews, a survey and literature review. The first step towards meeting the aim of research was to characterise and assess national instruments in the Netherlands. In the absence of an assessment framework for policy instruments in this domain one was created using elements of the theory based evaluation method and concepts from literature. All national energy performance instruments operating at the time that could influence energy performance improvement for space and water heating in existing dwellings were included in the evaluation. Data was obtained from face to face semi-structured interviews with 19 stakeholders involved in lobbying, designing, implementing and evaluating instruments. Interviewee data was complemented with secondary sources, including; evaluations of the national climate change programme, evaluations of individual instruments, cross country evaluations and European projects in which the Netherlands participated. An online survey of owner-occupiers covering the same instruments as the characterization and assessment of instruments described above was conducted to expand the investigation into instruments. More than 5,000 Dutch owner-occupiers participated in the survey. The survey consisted of 96 questions about energy saving measures adopted within the years preceding the survey. The focus lay on measures that involved significant investment to reduce energy consumed for space and water heating. The questionnaire consisted of multiple choice and open ended

  20. Quality of local authority occupational therapy services: developing an instrument to measure the user's perspective.

    NARCIS (Netherlands)

    Calnan, S.; Sixma, H.J.; Calnan, M.W.; Groenewegen, P.P.

    2000-01-01

    The aims of this paper are threefold: (1) to describe the development of an instrument measuring quality of care from the specific perspective of the users of local authority occupational therapy services; (2) to present the results from a survey of users' views about the quality of services offered

  1. Neighborhood Disadvantage, Residential Stability, and Perceptions of Instrumental Support among New Mothers

    Science.gov (United States)

    Turney, Kristin; Harknett, Kristen

    2010-01-01

    Using longitudinal data from the Fragile Families and Child Wellbeing survey (N = 4,211), this study examines neighborhood disadvantage and perceptions of instrumental support among mothers with young children. The authors find that (a) living in a disadvantaged neighborhood is associated with less instrumental support, particularly financial…

  2. Latest Results of the SETHI Survey at Arecibo

    Science.gov (United States)

    Korpela, E. J.; Demorest, P.; Heien, E.; Heiles, C.; Werthimer, D.

    2004-10-01

    SETH i is a survey of the distribution of galactic neutral hydrogen being performed comensally at the NAIC Arecibo Observatory. At the same time that observers use receivers in the Gregorian dome, SETHi is recording a 2.5MHz band centered at 1420 MHz from a flat feed on Carriage House 1. During normal astronomical observations, the SETH i feed scans across the sky at twice the sidereal rate. During 4 years of observations, we have accumulated over 15,000 hours of data covering most of the sky accessible to Arecibo. This survey has higher angular resolution than existing single dish surveys and higher sensitivity than existing or planned interferometric surveys.

  3. A method to automate the radiological survey process

    International Nuclear Information System (INIS)

    Berven, B.A.; Blair, M.S.

    1987-01-01

    This document describes the USRAD system, a hardware/software ranging and data transmission system, that provides real-time position data and combines it with other portable instrument measurements. Live display of position data and onsite data reduction, presentation, and formatting for reports and automatic transfer into databases are among the unusual attributes of USRADS. Approximately 25% of any survey-to-survey report process is dedicated to data recording and formatting, which is eliminated by USRADS. Cost savings are realized by the elimination of manual transcription of instrument readout in the field and clerical formatting of data in the office. Increased data reliability is realized by ensuring complete survey coverage of an area in the field, by elimination of mathematical errors in conversion of instrument readout to unit concentration, and by elimination of errors associated with transcribing data from the field into report format. The USRAD system can be adapted to measure other types of pollutants or physical/chemical/geological/biological conditions in which portable instrumentation exists. 2 refs., 2 figs

  4. FIRBACK Far Infrared Survey with ISO: Data Reduction, Analysis and First Results

    OpenAIRE

    Dole, Herve; Lagache, Guilaine; Puget, Jean-Loup; Gispert, Richard; Aussel, H.; Bouchet, F. R.; Ciliegi, C.; Clements, D. L.; Cesarsky, C.; Desert, F-X; Elbaz, D.; Franceschini, A.; Guiderdoni, B.; Harwit, M.; Laureijs, R.

    1999-01-01

    FIRBACK is one of the deepest cosmological surveys performed in the far infrared, using ISOPHOT. We describe this survey, its data reduction and analysis. We present the maps of fields at 175 microns. We point out some first results: source identifications with radio and mid infrared, and source counts at 175 microns. These two results suggest that half of the FIRBACK sources are probably at redshifts greater than 1. We also present briefly the large follow-up program.

  5. Radon in Irish schools: the results of a national survey

    International Nuclear Information System (INIS)

    Synnott, H; Hanley, O; Fenton, D; Colgan, P A

    2006-01-01

    This paper presents the results of a survey of radon concentrations in Irish primary and post-primary schools. The objective of this survey was to assess the distribution of radon in Irish schools and to identify those requiring remedial work to reduce radon exposure to children and staff. All primary and post-primary schools were invited to participate in the survey. Indoor radon concentrations were measured during the academic year using integrating passive alpha track-etch detectors with a measurement period from three to nine months. The survey was carried out on a phased basis from 1998 to 2004 and is one of the most comprehensive of its kind undertaken in Europe. Measurements were completed in 38 531 ground floor classrooms and offices in 3826 schools, representing over 95% of the approximate 4000 primary and post-primary schools in Ireland. Of these, 984 schools had radon concentrations greater than 200 Bq m -3 in 3028 rooms and 329 schools had radon concentrations in excess of 400 Bq m -3 in 800 rooms. The average radon concentration in schools was 93 Bq m -3 . This results in an annual average effective dose to an Irish child from exposure to radon of 0.3 mSv per year, assuming that the long-term radon concentration is equal to the radon concentration present during the working hours and that the annual average occupancy is 1000 h per year. A programme of remediation of schools with radon concentrations above 200 Bq m -3 has been put in place

  6. Safety culture in regulatory expert organization : analysis result of survey for KINS employees

    International Nuclear Information System (INIS)

    Choi, G. S.; Choi, Y. S.

    2003-01-01

    Much has been discussed on safety culture of operating organizations, however, little has been done on that of regulatory organization. Current issues and activities related to nuclear safety culture at IAEA, OECD/NEA, etc. were investigated and relevant literatures were reviewed. Elements essential for safety culture of regulatory organization were proposed and survey questionnaire for employees of regulatory expert organization, KINS, was developed based on the elements proposed. The survey result was presented and its implications were discussed. Based on the result, elements of safety culture in regulatory organization were proposed. The result of this survey can be used in developing safety culture model of regulatory organization, measurement method and also promotion of safety culture in regulatory organization

  7. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  8. A Practitioner's Instrument for Measuring Secondary Mathematics Teachers' Beliefs Surrounding Learner-Centered Classroom Practice.

    Science.gov (United States)

    Lischka, Alyson E; Garner, Mary

    In this paper we present the development and validation of a Mathematics Teaching Pedagogical and Discourse Beliefs Instrument (MTPDBI), a 20 item partial-credit survey designed and analyzed using Rasch measurement theory. Items on the MTPDBI address beliefs about the nature of mathematics, teaching and learning mathematics, and classroom discourse practices. A Rasch partial credit model (Masters, 1982) was estimated from the pilot study data. Results show that item separation reliability is .96 and person separation reliability is .71. Other analyses indicate the instrument is a viable measure of secondary teachers' beliefs about reform-oriented mathematics teaching and learning. This instrument is proposed as a useful measure of teacher beliefs for those working with pre-service and in-service teacher development.

  9. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer chemotherapy.

    Science.gov (United States)

    Lee, Clara N; Wetschler, Matthew H; Chang, Yuchiao; Belkora, Jeffrey K; Moy, Beverly; Partridge, Ann; Sepucha, Karen R

    2014-08-20

    Women diagnosed with early stage (I or II) breast cancer face a highly challenging decision - whether or not to undergo adjuvant chemotherapy. We developed a decision quality instrument for chemotherapy for early stage breast cancer and sought to evaluate its performance. Cross-sectional, mailed survey of recent breast cancer survivors, providers, and healthy controls and a retest survey of survivors. The decision quality instrument includes questions on knowledge and personal goals. It results in a knowledge score and concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, validity, and reliability of the survey instrument were examined. Responses were received from 352 patients, 89 providers and 35 healthy controls. The decision quality instrument was feasible to implement with few missing data. The knowledge scores had good retest reliability (intraclass correlation coefficient (ICC) =0.75). Knowledge scores discriminated between providers and patients (mean difference 31.1%, 95% CI 26.9, 35.3) and between patients and healthy controls (mean difference 11.2, 95% CI 5.4, 17.1). Most providers reported that the knowledge items covered essential content. Two of the five goal items had a ceiling effect, and one goal had low content validity. The goal items had moderate retest reliability (ICC's 0.57 to 0.78). In the multivariable model of treatment, none of the patient goals was associated with receipt of chemotherapy. Age and hormone receptor status were the only variables independently associated with chemotherapy. Most patients (77.6%) had treatment concordant with that predicted by the model. Patients who had concordant treatment had similar levels of confidence and regret as those who did not. The Decision Quality Instrument is a reliable and valid measure of patient knowledge about chemotherapy, but its ability to measure concordance with patient goals is

  10. Safety climate in Swiss hospital units: Swiss version of the Safety Climate Survey

    Science.gov (United States)

    Gehring, Katrin; Mascherek, Anna C.; Bezzola, Paula

    2015-01-01

    Abstract Rationale, aims and objectives Safety climate measurements are a broadly used element of improvement initiatives. In order to provide a sound and easy‐to‐administer instrument for the use in Swiss hospitals, we translated the Safety Climate Survey into German and French. Methods After translating the Safety Climate Survey into French and German, a cross‐sectional survey study was conducted with health care professionals (HCPs) in operating room (OR) teams and on OR‐related wards in 10 Swiss hospitals. Validity of the instrument was examined by means of Cronbach's alpha and missing rates of the single items. Item‐descriptive statistics group differences and percentage of ‘problematic responses’ (PPR) were calculated. Results 3153 HCPs completed the survey (response rate: 63.4%). 1308 individuals were excluded from the analyses because of a profession other than doctor or nurse or invalid answers (n = 1845; nurses = 1321, doctors = 523). Internal consistency of the translated Safety Climate Survey was good (Cronbach's alpha G erman = 0.86; Cronbach's alpha F rench = 0.84). Missing rates at item level were rather low (0.23–4.3%). We found significant group differences in safety climate values regarding profession, managerial function, work area and time spent in direct patient care. At item level, 14 out of 21 items showed a PPR higher than 10%. Conclusions Results indicate that the French and German translations of the Safety Climate Survey might be a useful measurement instrument for safety climate in Swiss hospital units. Analyses at item level allow for differentiating facets of safety climate into more positive and critical safety climate aspects. PMID:25656302

  11. Validation of the National Institutes of Health Patient-Reported Outcomes Measurement Information System Survey as a Quality-of-Life Instrument for Patients with Malignant Brain Tumors and Their Caregivers.

    Science.gov (United States)

    Romero, Melissa M; Flood, Lisa Sue; Gasiewicz, Nanci K; Rovin, Richard; Conklin, Samantha

    2015-12-01

    At present there is a lack of well-validated surveys used to measure quality of life in patients with malignant brain tumors and their caregivers. The main objective of this pilot study was to validate the National Institutes of Health Patient-Reported Outcomes Measurement Information System (NIH PROMIS) survey for use as a quality-of-life measure in this population. This article presents the rationale for using the NIH PROMIS instrument as a quality-of-life measure for patients with malignant brain tumors and their caregivers. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Education in Psychopathology in Europe: Results from a Survey in 32 Countries.

    Science.gov (United States)

    Fiorillo, Andrea; Sampogna, Gaia; Del Vecchio, Valeria; Luciano, Mario; Ambrosini, Alessandra; Stanghellini, Giovanni

    2016-04-01

    The aim of the present paper is to assess the current status of training on psychopathology in Europe and to identify the unmet needs of training on psychopathology. An online survey was carried out during the period July-December 2013. Forty-one representatives of early career psychiatrists of their national associations were invited to participate. Each respondent was asked to provide the collective feedback of the association rather than that of any of its individual officer or member. Thirty-two associations returned the questionnaire out of the 41 contacted (response rate, 78%). All respondents recognized psychopathology as a core component of training in psychiatry. According to respondents, the primary aims of psychopathology are (a) to assess psychiatric symptoms (47%), (b) to understand patients' abnormal experiences (33%), and (c) to make nosographical diagnosis (20%). A formal training course in psychopathology is available in 29 out of the 32 surveyed countries. In most countries, (a) there is not a defined number of hours dedicated to psychopathology, (b) teaching is mainly theoretical, and (c) a structured training on psychometric tools is missing. At the end of the training, about half of trainees is not satisfied with received training in psychopathology. According to European early career psychiatrists, there is the need to rethink training in psychopathology, which should be at the heart of training in psychiatry and the key element of psychiatric practice. Education in psychopathology is affected by several unmet needs, such as lack of appropriate training in the use of psychometric instruments, lack of supervision, and lack of practical skills.

  13. Radiometric survey in mammography: problems and challenges; Levantamento radiometrico em mamografia: problemas e desafios

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, M.V.T.; Navarro, V.C.C.; Garcia, I.F.M.; Ferreira, M.J.; Macedo, E.M., E-mail: navarro@ifba.edu.br [Instituto Federal da Bahia (LABPROSAUD/IFBA), Salvador, BA (Brazil). Laboratorio de Produtos para a Saude

    2015-07-01

    In addition to being mandatory, the radiometric survey is a necessity, especially in the Brazilian reality with the construction of smaller and smaller rooms. However, calibration conditions, the instrumentation and its use, can produce underestimated factors. Measures made at Labprosaud/IFBA, with five different instruments and the ISO N 25 radiation quality, show the possibility of the values presented in the radiometric surveys are underestimated by up to 10 times. The results indicate the need for meters to be calibrated in ISO N qualities, in mammography energy range, in integrated dose mode and exposure times shorter or equal to 1 s. (author)

  14. The HIFI spectral survey of AFGL 2591 (CHESS). II. Summary of the survey

    Science.gov (United States)

    Kaźmierczak-Barthel, M.; van der Tak, F. F. S.; Helmich, F. P.; Chavarría, L.; Wang, K.-S.; Ceccarelli, C.

    2014-07-01

    Aims: This paper presents the richness of submillimeter spectral features in the high-mass star forming region AFGL 2591. Methods: As part of the Chemical Herschel Survey of Star Forming Regions (CHESS) key programme, AFGL 2591 was observed by the Herschel (HIFI) instrument. The spectral survey covered a frequency range from 480 to 1240 GHz as well as single lines from 1267 to 1901 GHz (i.e. CO, HCl, NH3, OH, and [CII]). Rotational and population diagram methods were used to calculate column densities, excitation temperatures, and the emission extents of the observed molecules associated with AFGL 2591. The analysis was supplemented with several lines from ground-based JCMT spectra. Results: From the HIFI spectral survey analysis a total of 32 species were identified (including isotopologues). Although the lines are mostly quite weak (∫TmbdV ~ few K km s-1), 268 emission and 16 absorption lines were found (excluding blends). Molecular column densities range from 6 × 1011 to 1 × 1019 cm-2 and excitation temperatures from 19 to 175 K. Cold (e.g. HCN, H2S, and NH3 with temperatures below 70 K) and warm species (e.g. CH3OH, SO2) in the protostellar envelope can be distinguished. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.Appendix A is available in electronic form at http://www.aanda.org

  15. The THU-NAOC transient survey: the performance and results from the first year

    International Nuclear Information System (INIS)

    Zhang Tian-Meng; Zhou Xu; Nie Jun-Dan; Jiang Zhao-Ji; Ma Jun; Wang Ling-Zhi; Zhou Zhi-Min; Zou Hu; Wang Xiao-Feng; Chen Jun-Cheng; Zhou Li; Li Wen-Xiong; Liu Qing; Mo Jun; Zhang Kai-Cheng; Yao Xin-Yu; Zhao Xu-Lin; Huang Fang; Zhang Ju-Jia; Wu Chao

    2015-01-01

    The Tsinghua University-National Astronomical Observatories, Chinese Academy of Sciences (NAOC) Transient Survey is an automatic survey that conducts a systematic exploration of optical transients. This project utilizes a 60/90 cm Schmidt telescope at the Xinglong Station of NAOC. This survey repeatedly covers ∼ 1000 square degrees of the northern sky with a cadence of 3–4 d. With an exposure of 60 s, the survey reaches a limiting unfiltered magnitude of about 19.5 mag, which enables us to discover supernovae in their relatively young stages. We describe the overall performance of our survey during the first year and present some preliminary results. (research papers)

  16. Digital Education Governance: Data Visualization, Predictive Analytics, and "Real-Time" Policy Instruments

    Science.gov (United States)

    Williamson, Ben

    2016-01-01

    Educational institutions and governing practices are increasingly augmented with digital database technologies that function as new kinds of policy instruments. This article surveys and maps the landscape of digital policy instrumentation in education and provides two detailed case studies of new digital data systems. The Learning Curve is a…

  17. Rethinking Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    It is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as self-control, growth mindsets, and grit. Increasingly, such instruments are being used not only for basic research but also for supporting decisions regarding educational policy and accountability. The…

  18. Quality of Academic Advising at UNO: Results of Student and Faculty Surveys.

    Science.gov (United States)

    ESS Reports, 1988

    1988-01-01

    This report presents the results of a student/faculty survey on the academic advising process at the University of Nebraska at Omaha, and highlights issues in improving the advising process. The survey included 195 recent graduates, 269 existing students, and 207 faculty and professional advisors. The study found that 70.8% of students were…

  19. Daylighting practices of the architectural industry (baseline results of a national survey)

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1990-05-01

    A national survey of over 300 commercial design architects was conducted to develop baseline information on their knowledge, perceptions, and use of daylighting in commercial building designs. Pacific Northwest Laboratory conducted the survey for the US Department of Energy's (DOE) Office of Building and Community Systems (BCS). In the survey daylighting was defined as the intentional use of natural light as a partial substitute for artificially generated light. The results suggested that architects need to be educated about the true benefits of daylighting and the impacts it can have on a building's energy performance. Educational programs that will increase the architects' understanding and awareness of modern daylighting technologies and practices should be developed by utilities, stage agencies, and the federal government. If more architects can be made aware of the true effectiveness and positive attributes of daylighting systems and technologies, daylighting may be used in more commercial buildings. The results of the survey show that the more familiar architects feel they are with daylighting, the more they use daylighting. 3 refs., 19 tabs.

  20. Initial communication survey results for the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Beck, D.M.

    1991-03-01

    To support the public communication efforts of the Technical Steering Panel of the Hanford Environmental Dose Reconstruction (HEDR) Project, a public survey was conducted. The survey was intended to provide information about the public's knowledge and interest in the project and the best ways to communicate project results. Questions about the project were included as part of an omnibus survey conducted by Washington State University. The survey was conducted by phone to Washington State residents in the spring of 1990. This report gives the HEDR-related questions and summary data of responses. Questions associated with the HEDR Project were grouped into four categories: knowledge of the HEDR Project; interest in the project; preferred ways of receiving information about the project (including public information meetings, a newsletter mailed to homes, presentations to civic groups in the respondent's community, a computer bulletin board respondent could access with a modem, information displays at public buildings and shopping malls, and an information video sent to respondent); and level of concern over past exposure from Hanford operations. Questions abut whom state residents are most likely to trust about radiation issues were also part of the omnibus survey, and responses are included in this report

  1. Survey of instrumentation used for monitoring metals in water

    Energy Technology Data Exchange (ETDEWEB)

    Quinby-Hunt, M.S.

    1978-06-01

    A study was conducted of instrumentation used to determine metals in water. Several of the techniques most commonly used for analysis and routine determinations of metals in water are shown in Table 1. They are atomic absorption spectroscopy, both flame and flameless, atomic emission spectroscopy using conventional flame sources and inductively-coupled plasma sources, and ultraviolet-visible absorption techniques. Other less frequently employed methods are x-ray fluorescence analysis using both photon and charged particle excitation with energy-dispersive and wavelength-dispersive spectral analysis. Also electrochemical techniques and activation analysis are studied.

  2. Developing, testing, and implementing a survey of scientist mentoring teachers as part of an RET: The GABI RET mentor survey.

    Science.gov (United States)

    Davey, B.

    2017-12-01

    The impacts of mentoring in education have been well established. Mentors have a large impact on their mentees and have been show to affect mentee attitudes towards learning, interest in subjects, future success, and more. While mentoring has a well-documented impact on the mentees, mentoring also has an impact on the mentors themselves. However, little has been studied empirically about these impacts. When we looked for a validated instrument that measured the impact of mentoring on the scientists working with the teachers, we found many anecdotal reports but no instruments that meet our specific needs. To this end, we developed, tested, and implemented our own instrument for measuring the impacts of mentoring on our scientist mentors. Our instrument contained both quantitative and qualitative items designed to reveal the effects of mentoring in two areas: 1) cognitive domain (mentoring, teaching, understanding K-12) and 2) affective domain (professional, personal, participation). We first shared our survey with experts in survey development and mentoring, gathered their feedback, and incorporated their suggestions into our instrument. We then had a subsection of our mentors complete the survey and then complete it again three to four days later (test-retest). Our survey has a high correlation for the test-retest quantitative items (0.93) and a high correlation (0.90) between the three reviewers of the qualitative items. From our findings, we feel we have a validated instrument (face, content, and contruct validity) that answers our research questions reliably. Our contribution to the study of mentoring of science teachers reveals a broad range of impacts on the mentors themselves including an improved understanding of the challenges of classroom teaching, a recognition of the importance of scientists working with science teachers, an enhanced ability to communicate their research and findings, and an increased interest and excitement for their own work.

  3. National Survey on Access, Use and Promotion of Rational Use of Medicines (PNAUM: household survey component methods

    Directory of Open Access Journals (Sweden)

    Sotero Serrate Mengue

    Full Text Available ABSTRACT OBJECTIVE To describe methodological aspects of the household survey National Survey on Access, Use and Promotion of Rational Use of Medicines (PNAUM related to sampling design and implementation, the actual obtained sample, instruments and fieldwork. METHODS A cross-sectional, population-based study with probability sampling in three stages of the population living in households located in Brazilian urban areas. Fieldwork was carried out between September 2013 and February 2014. The data collection instrument included questions related to: information about households, residents and respondents; chronic diseases and medicines used; use of health services; acute diseases and events treated with drugs; use of contraceptives; use of pharmacy services; behaviors that may affect drug use; package inserts and packaging; lifestyle and health insurance. RESULTS In total, 41,433 interviews were carried out in 20,404 households and 576 urban clusters corresponding to 586 census tracts distributed in the five Brazilian regions, according to eight domains defined by age and gender. CONCLUSIONS The results of the survey may be used as a baseline for future studies aiming to assess the impact of government action on drug access and use. For local studies using a compatible method, PNAUM may serve as a reference point to evaluate variations in space and population. With a comprehensive evaluation of drug-related aspects, PNAUM is a major source of data for a variety of analyses to be carried out both at academic and government level.

  4. Results of the 2015 National Certified Pharmacy Technician Workforce Survey.

    Science.gov (United States)

    Desselle, Shane P; Holmes, Erin R

    2017-07-01

    The results of the 2015 National Certified Pharmacy Technician Workforce Survey are described. A survey was e-mailed to a randomized sample of 5,000 certified pharmacy technicians (CPhTs) throughout the United States, with response reminders employed. Survey items eliciting demographic and work characteristics and work life attitudes were generated from the literature and qualitative interviews. This study aimed to describe job satisfaction, sources of stress, profession and employer commitment, education and training, and reasons for entry into the profession among CPhTs and determine relationships between those variables and CPhTs' level of involvement in various work activities, with particular attention paid to differences in practice setting. Frequency statistics, correlation analysis, and means testing were used to meet study objectives and identify significant differences. A total of 516 CPhTs currently working as a pharmacy technician responded to the survey. The CPhTs reported high levels of involvement in more traditional activities but less involvement in those that involve greater cognitive load. Respondents reported moderate levels of job satisfaction and commitment and somewhat high levels of stress overall. Most CPhTs chose to be a pharmacy technician because they desired to enter a healthcare field and help people and were recruited. CPhTs derived benefit from all aspects of education and training evaluated and most from on-the-job training. Perceived value of education and training was associated with higher satisfaction and commitment and with lower stress. There were a number of differences in these work life attitudes across practice settings and by involvement in various job functions. The results of the survey indicated that job satisfaction and commitment were moderate and that stress levels were somewhat high among CPhTs. There were a number of differences in work life attitudes across practice settings and by involvement in various job

  5. OECD Skills Outlook 2013: First Results from the Survey of Adult Skills

    Science.gov (United States)

    OECD Publishing, 2013

    2013-01-01

    This first "OECD Skills Outlook" presents the initial results of the Survey of Adult Skills (PIAAC), which evaluates the skills of adults in 22 OECD member countries and two partner countries. The PIAAC survey was designed to provide insights into the availability of some key skills and how they are used at work and at home through the…

  6. Bridge Programs in Illinois: Results of the 2010 Illinois Bridge Status Survey

    Science.gov (United States)

    Taylor, J. L.; Harmon, T.

    2010-01-01

    This report provides a summary of major results of the Illinois Bridge Status Survey, administered online between April and June 2010. The purpose of the survey was to understand the extent to which bridge programs are being implemented in Illinois, as well as to build an online directory of bridge programs. Bridge programs are an emerging…

  7. On-line instrument for control of water and steam quality at energy production plants - a market survey

    International Nuclear Information System (INIS)

    Fahlgren, N.; Persson, F.

    1988-10-01

    Instruments for on-line measuring are today available for all water analyses that can be of intrerest in power stations. For some of the analyses instruments have been in operation for many years e.g. for determination of silica, sodium and oxygen. For other analyses no instruments or only a few have been in operation. Many instruments are developed under the last years. Operation experiences for many instruments are therefore limited. For mostly all instruments, also for instruments that have been in operation a long time, operation experiences from the same type of instruments differ from plant to plant. The reson is that most of the instruments need daily or weekly maintenance and that has not always been aquainted. The time for necessary maintenance is however not so long that it is deterrent. The time for necessary maintenance for an instrument is normally 1-2 hours a week. On-line measuring, improve supervision and reliability of service and are therefore to recommend in both big and small plants. In small plants it is very important to have a good supervision of pH-value, conductivity, harness and the content of oxygen in feed water. (authors)

  8. ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

    Science.gov (United States)

    1990-01-01

    In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its

  9. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  10. Deployment of Intelligent Transportation Systems: A Summary of the 2016 National Survey Results

    Science.gov (United States)

    2018-03-01

    This report presents summary results of the 2016 ITS Deployment Tracking survey, the most recent survey conducted through the ITS Deployment Tracking Project. The U.S. Department of Transportation and the ITS Joint Program Office have pursued a resea...

  11. The Development of Precise Engineering Surveying Technology

    Directory of Open Access Journals (Sweden)

    LI Guangyun

    2017-10-01

    Full Text Available With the construction of big science projects in China, the precise engineering surveying technology developed rapidly in the 21th century. Firstly, the paper summarized up the current development situation for the precise engineering surveying instrument and theory. Then the three typical cases of the precise engineering surveying practice such as accelerator alignment, industry measurement and high-speed railway surveying technology are focused.

  12. Analysis of the Herschel/Hexos Spectral Survey Toward Orion South: A Massive Protostellar Envelope with Strong External Irradiation

    NARCIS (Netherlands)

    Tahani, K.; Plume, R.; Bergin, E. A.; Tolls, V.; Phillips, T. G.; Caux, E.; Cabrit, S.; Goicoechea, J. R.; Goldsmith, P. F.; Johnstone, D.; Lis, D. C.; Pagani, L.; Menten, K. M.; Müller, H. S. P.; Ossenkopf-Okada, V.; Pearson, J. C.; van der Tak, F. F. S.

    2016-01-01

    We present results from a comprehensive submillimeter spectral survey toward the source Orion South, based on data obtained with the Heterodyne Instrument for the Far-Infrared instrument on board the Herschel Space Observatory, covering the frequency range of 480 to 1900 GHz. We detect 685 spectral

  13. Calibration results using highly aberrated images for aligning the JWST instruments to the telescope

    Science.gov (United States)

    Smith, Koby Z.; Acton, D. Scott; Gallagher, Ben B.; Knight, J. Scott; Dean, Bruce H.; Jurling, Alden S.; Zielinski, Thomas P.

    2016-07-01

    mostly of 3rd-order astigmatism and coma. This is because the elliptical tertiary mirror of the AOS is used off of its ideal foci locations without the compensating wavefront effects of the JWST primary and secondary mirrors. Therefore, the PSFs created are highly asymmetric with relatively complex structure and the centroid and encircled energy analyses traditionally used to locate images are not sufficient for ensuring the AOS to ISIM alignment. A novel approach combining phase retrieval and spatial metrology was developed to both locate the images with respect to the AOS and provide calibration information for eventual AOS to ISIM alignment verification. During final JWST OTE and ISIM (OTIS) testing, only a single thru-focus image will be collected by the instruments. Therefore, tools and processes were developed to perform single-image phase retrieval on these highly aberrated images such that any single image of the ASPA source can provide calibrated knowledge of the instruments' position relative to the AOS. This paper discusses the results of the methodology, hardware, and calibration performed to ensure that the AOS and ISIM are aligned within their respective tolerances at JWST OTIS testing.

  14. Association of Sleep Groups and Sleep Survey Results of High School Students

    Science.gov (United States)

    Anderson, Stephen A.; MacDonald, Lawrence; Frost, Frederica C.

    2006-01-01

    In January 2003 the High School Late Start Committee of the Northville Public Schools sent surveys to all families, faculty, and middle and high school students. The descriptive results of this survey can be found at www.northville.k12.mi.us/hr/late_start_committee_surveysummary.htm. This study focuses on the responses of the high school students,…

  15. Design and validation of portable optical instrument for crop diagnose

    Science.gov (United States)

    Sun, Gang; Zheng, Wengang; Huang, Wengjiang; Wan, Huawei; Liu, Liangyun

    2005-12-01

    In this paper, a portable diagnostic instrument was designed and tested, which can measure the normalized difference vegetation index (NDVI) and structure insensitive pigment index (SIPI) of crop canopy in field. The instrument have a valid survey area of 1 m*1 m when the height between instrument and the ground was fixed to 1.3 meter The crop growth condition can be assessed based on their NDVI and SIPI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. This paper also provided the method of calibration, the results showed that the average measurement error to SIPI value of instrument was 5.25% and the average measurement error to NDVI value in vegetation-covered region is 6.40%. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field.

  16. The Development of a Tactical-Level Full Range Leadership Measurement Instrument

    Science.gov (United States)

    2010-03-01

    full range leadership theory has become established as the predominant and most widely researched theory on leadership . The most commonly used survey...instrument to assess full range leadership theory is the Multifactor Leadership Questionnaire, originally developed by Bass in 1985. Although much...existing literature to develop a new full range leadership theory measurement instrument that effectively targets low- to mid-level supervisors, or

  17. Towards the development of an outcome instrument for spinal trauma: an international survey of spinal surgeons.

    Science.gov (United States)

    Oner, F Cumhur; Sadiqi, Said; Lehr, A Mechteld; Dvorak, Marcel F; Aarabi, Bizhan; Chapman, Jens R; Fehlings, Michael G; Kandziora, Frank; Rajasekaran, S; Vaccaro, Alexander R

    2015-01-15

    International web-based survey. To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. There is no universally accepted outcome instrument available that is specifically designed or validated for spinal trauma patients, contributing to controversies related to the optimal treatment and evaluation of many types of spinal injuries. Therefore, the AOSpine Knowledge Forum Trauma aims to develop such an instrument using the International Classification of Functioning, Disability, and Health (ICF) as its basis. Experts from the 5 AOSpine International world regions were asked to give their opinion on the relevance of a compilation of 143 ICF categories for spinal trauma patients on a 3-point scale: "not relevant," "probably relevant," or "definitely relevant." The responses were analyzed using frequency analysis. Possible differences in responses between the 5 world regions were analyzed with the Fisher exact test and descriptive statistics. Of the 895 invited AOSpine International members, 150 (16.8%) participated in this study. A total of 13 (9.1%) ICF categories were identified as definitely relevant by more than 80% of the participants. Most of these categories were related to the ICF component "activities and participation" (n = 8), followed by "body functions" (n = 4), and "body structures" (n = 1). Only some minor regional differences were observed in the pattern of answers. More than 80% of an international group of health care professionals experienced in the clinical care of adult spinal trauma patients indicated 13 of 143 ICF categories as definitely relevant to measure outcomes after spinal trauma. This study creates an evidence base to define a core set of ICF categories for outcome measurement in adult spinal trauma patients.

  18. A positioning and data logging system for surface geophysical surveys

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Blair, M.S.

    1988-01-01

    The Ultrasonic Ranging and Data System (USRADS) developed at ORNL is being adapted to work with two commercially available geophysical instruments: a magnetometer and an EM31 terrain conductivity meter. Geophysical surveys have proven an important preliminary step in investigating hazardous waste sites. Magnetometers and terrain conductivity meters are used to locate buried drums, trenches, conductive contaminant plumes and map regional changes in geology. About half the field time of a typical geophysical investigation is spent surveying the position of the grid points at which the measurements will be made. Additional time is lost and errors may be made recording instrument values in field notebooks and transcribing the data to a computer. Developed for gamma radiation surveys, the USRAD system keeps track of the surveyor's position automatically by triangulating on an ultrasonic transmitter carried in a backpack. The backpack also contains a radio transmitter that sends the instrument's reading coincident with the ultrasonic pulse. The surveyor's position and the instrument's reading are recorded by a portable computer which can plot the data to check the survey's progress. Electronic files are stored in a form compatible with AutoCAD to speed report writing. 7 refs., 3 figs

  19. The Influence of Student Experiences on Post-Graduation Surveys

    Science.gov (United States)

    Hirschberg, Joe; Lye, Jenny

    2016-01-01

    This study attempts to establish the extent to which in-class teaching quality instruments can be used to predict post-graduation survey results. It examines the responses for the Good Teaching Scale of the Course Experience Questionnaire administered to 10,433 students who completed their studies at a major Australian tertiary institution from…

  20. Report on the results of the safety culture survey conducted in PNRI

    International Nuclear Information System (INIS)

    Garcia, Corazon M.; Nohay, Carl M.; Badinas, Nelson P.; Melendez, Johnylen V.; Parami, Vangeline K.

    2001-01-01

    An initial safety culture survey was conducted in the Philippine Nuclear Research Institute (PNRI). Sixty six (66) questionnaires as given in A. Adams and A. Williamson's Measurement of Safety Culture in the Nuclear Industry, UNSW, July 1999 were distributed to the different units of PNRI. The number of sets of survey sheets distributed to the different units corresponded to the number of personnel in the unit based on the information obtained from them. Results were obtained from only 33 respondents. ANSTO has been requested to analyze the results of this survey. While waiting for the results from ANSTO, we attempted to proceed with this analysis in order to learn and practice applying the procedure based on the reference cited above.The respondents from the PNRI showed on the overall neutral views towards safety and their work. Although a minority showed positive responses to safety while a small minority showed negative responses. A remarkable result is that all respondents show strong concern over the welfare of the institute, indicating that there is still a good chance for safety culture to be developed positively among the employees given the proper strategies for motivation. (author)

  1. A New Automated Instrument Calibration Facility at the Savannah River Site

    International Nuclear Information System (INIS)

    Polz, E.; Rushton, R.O.; Wilkie, W.H.; Hancock, R.C.

    1998-01-01

    The Health Physics Instrument Calibration Facility at the Savannah River Site in Aiken, SC was expressly designed and built to calibrate portable radiation survey instruments. The facility incorporates recent advances in automation technology, building layout and construction, and computer software to improve the calibration process. Nine new calibration systems automate instrument calibration and data collection. The building is laid out so that instruments are moved from one area to another in a logical, efficient manner. New software and hardware integrate all functions such as shipping/receiving, work flow, calibration, testing, and report generation. Benefits include a streamlined and integrated program, improved efficiency, reduced errors, and better accuracy

  2. Development and Validation of a Novel Generic Health-related Quality of Life Instrument With 20 Items (HINT-20

    Directory of Open Access Journals (Sweden)

    Min-Woo Jo

    2017-01-01

    Full Text Available Objectives Few attempts have been made to develop a generic health-related quality of life (HRQoL instrument and to examine its validity and reliability in Korea. We aimed to do this in our present study. Methods After a literature review of existing generic HRQoL instruments, a focus group discussion, in-depth interviews, and expert consultations, we selected 30 tentative items for a new HRQoL measure. These items were evaluated by assessing their ceiling effects, difficulty, and redundancy in the first survey. To validate the HRQoL instrument that was developed, known-groups validity and convergent/discriminant validity were evaluated and its test-retest reliability was examined in the second survey. Results Of the 30 items originally assessed for the HRQoL instrument, four were excluded due to high ceiling effects and six were removed due to redundancy. We ultimately developed a HRQoL instrument with a reduced number of 20 items, known as the Health-related Quality of Life Instrument with 20 items (HINT-20, incorporating physical, mental, social, and positive health dimensions. The results of the HINT-20 for known-groups validity were poorer in women, the elderly, and those with a low income. For convergent/discriminant validity, the correlation coefficients of items (except vitality in the physical health dimension with the physical component summary of the Short Form 36 version 2 (SF-36v2 were generally higher than the correlations of those items with the mental component summary of the SF-36v2, and vice versa. Regarding test-retest reliability, the intraclass correlation coefficient of the total HINT-20 score was 0.813 (p<0.001. Conclusions A novel generic HRQoL instrument, the HINT-20, was developed for the Korean general population and showed acceptable validity and reliability.

  3. Victimisation surveys: What are they good for?

    Directory of Open Access Journals (Sweden)

    Aromaa Kauko

    2012-01-01

    Full Text Available The author analyzes the usefulness of victimization surveys. The paper is focused of surveys in which nationally representative population samples are surveyed for their personal victimisation experiences, and their attitudes and opinions of issues related to crime and crime control. The author points out the benefits of using victimization surveys, but also explains why most countries have failed to make systematic use of this instrument.

  4. Pilot information needs survey regarding climate relevant technologies

    International Nuclear Information System (INIS)

    Van Berkel, R.; Van Roekel, A.

    1997-02-01

    The objective of this pilot survey was to arrive at a preliminary understanding of the initial technology and technology information needs in non-Annex II countries in order to support international efforts to facilitate the transfer of technologies and know-how conducive to mitigating and adapting to climate change. The study encompassed two main components, i.e. the development of a survey instrument and the execution of a pilot survey among selected non-Annex II countries. The survey instrument addresses the present status of enabling activities; technology and technology information needs; and issues related to information supply and accessibility. The survey was distributed to national focal points in 20 non-Annex II countries and to at least 35 other stakeholders in five of these non-Annex II countries. A total of 27 completed questionnaires were received, covering 10 non-Annex II countries. 3 refs

  5. Pilot information needs survey regarding climate relevant technologies

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, R.; Van Roekel, A.

    1997-02-01

    The objective of this pilot survey was to arrive at a preliminary understanding of the initial technology and technology information needs in non-Annex II countries in order to support international efforts to facilitate the transfer of technologies and know-how conducive to mitigating and adapting to climate change. The study encompassed two main components, i.e. the development of a survey instrument and the execution of a pilot survey among selected non-Annex II countries. The survey instrument addresses the present status of enabling activities; technology and technology information needs; and issues related to information supply and accessibility. The survey was distributed to national focal points in 20 non-Annex II countries and to at least 35 other stakeholders in five of these non-Annex II countries. A total of 27 completed questionnaires were received, covering 10 non-Annex II countries. 3 refs.

  6. Preliminary Geological Survey on the Proposed Sites for the New Research Reactor

    International Nuclear Information System (INIS)

    Lim, In Cheol; Ha, J. J.; Oh, K. B.

    2010-12-01

    · Performing the preliminary geological survey on the proposed sites for the new research reactor through the technical service · Ordering a technical service from The Geological Society of Korea · Contents of the geological survey - Confirmation of active fault - Confirmation of a large-scale fracture zone or weak zone - Confirmation of inappropriate items related to the underground water - Confirmation of historical seismicity and instrumental earthquakes data · Synthesized analysis and holding a report meeting · Results of the geological survey - Confirmation of the geological characteristics of the sites and drawing the requirements for the precise geological survey in the future

  7. Corporate Entrepreneurship Assessment Instrument (CEAI): Refinement and Validation of a Survey Measure

    National Research Council Canada - National Science Library

    Cates, Michael S

    2007-01-01

    .... The measurement instrument known as the Corporate Entrepreneurship Assessment Index (CEAI) has been designed to tap the climate-related organizational factors that represent and potentially encourage corporate entrepreneurship...

  8. The Inner Magnetospheric Imager (IMI): Instrument heritage and orbit viewing analysis

    Science.gov (United States)

    Wilson, Gordon R.

    1992-12-01

    For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.

  9. Verification of radioactive contamination surveys for practical use in biological research centres

    International Nuclear Information System (INIS)

    Macias, M.T.; Requejo, C.; Ruiz, M.; Pina, R.

    2006-01-01

    Unsealed sources are commonly used in science research laboratories. Their manipulation may imply a radioactive contamination hazard. Therefore, adequate and sensitive survey meters must be available, and must have an effective and accurate response to intensity and type of radiation emitted by the used radionuclides to identify and quantify the possible contamination and then be able to avoid any associated or unwanted consequences that may arise. Periodic surveys are performed to show control, any time, any place radioactive contamination is suspected, and to ensure radioisotopes are being used safely. The immediate work areas must be often checked with portable survey monitors, including the entire lab and particularly bench tops, personnel protective equipment or solely designated equipment for isotope use (micro-fuges, water baths, incubators). These are carried out with portable survey instruments like Geiger-Muller tubes, proportional counters and scintillation detectors that provide direct or indirect measurements capabilities. The Radiation Safety Office (R.S.O.) as well as the radioactive compounds working laboratories at the Instituto de Inv. Biomedicas 'A. Sols' (Madrid-Spain) are provided with an adequate radiation measurement instrument. But, before a portable survey instrument is used, several quality checks should be made (batteries, calibration sticker), and the instrument response should be tested with a check source. This paper aims at determining, with a R.S.O. procedure, these surveys working parameters -detection efficiency, calibration factors and minimum detectable activities-, using reference checking sources ( 14 C, 36 Cl, and 90 Sr/ 90 Y) with known radioactivity covering the energy range of beta emitting isotopes used in biological research. No gamma portable monitors have been tested for the R.S.O. has no gamma checking sources. Therefore, 58 beta monitors were tested, obtaining t he efficiency values, the calibration factors (Bq cm-2 s

  10. Critical review of directional neutron survey meters

    Science.gov (United States)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument.

  11. Critical Review of Directional Neutron Survey Meters

    International Nuclear Information System (INIS)

    Balmer, M.J.I.; Gamage, K.A.A.; Taylor, G.C.

    2013-06-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. (authors)

  12. Status and needs for seismic instrumentation of structures along the Hayward fault

    Science.gov (United States)

    Kalkan, Erol; Çelebi, Mehmet

    2008-01-01

    The inventory of structures in heavily urbanized communities within the greater San Francisco (SF) Bay area that will experience strong ground motions from the rupture of the Hayward Fault includes a variety of types of recent and older structures built with a variety of materials and to different code standards. Those who remember the effects of the 1989 Loma Prieta earthquake on structures in the San Francisco Bay area also remember the collapse of one upper-deck segment of the Bay Bridge that halted transportation for approximately five weeks. In order to understand how these structures respond to earthquake motions and to improve building practices to resist these strong motions it is imperative that owners of these structures as well as governmental organizations acquire shaking response data from instrumented (or yet to be instrumented structures) during the forecast events. Within California, such data are acquired mainly by California Geological Survey and the United States Geological Survey. A small number of private owners contribute to this effort. The inventory of existing instrumented structures is much less than 0.1% of the total, and thus statistically it is not sufficient. For example, some of the existing important regular or lifeline structures are not instrumented(e.g. Bart Trans-Bay Tunnel, many segments of the Bart elevated structures in the proximity of the Hayward Fault, the yet to be completed eastern part of San Francisco Bay Bridge, Hetch-Hetchy pipeline system crossing the Hayward Fault)even though attempts and proposals have been developed to do so in the past. This paper presents a critical assessment of the status quo and the future needs for instrumentation of structures in the greater SF Bay area that includes the Hayward Fault. There are many new attempts and successes in instrumentation of structures in this region. Two successful examples are provided here, but more needs to be done. The paper does not present new research results

  13. a Circleless "2D/3D Total STATION": a Low Cost Instrument for Surveying, Recording Point Clouds, Documentation, Image Acquisition and Visualisation

    Science.gov (United States)

    Scherer, M.

    2013-07-01

    Hardware and software of the universally applicable instrument - referred to as a 2D/3D total station - are described here, as well as its practical use. At its core it consists of a 3D camera - often also called a ToF camera, a pmd camera or a RIM-camera - combined with a common industrial 2D camera. The cameras are rigidly coupled with their optical axes in parallel. A new type of instrument was created mounting this 2D/3D system on a tripod in a specific way. Because of it sharing certain characteristics with a total station and a tacheometer, respectively, the new device was called a 2D/3D total station. It may effectively replace a common total station or a laser scanner in some respects. After a brief overview of the prototype's features this paper then focuses on the methodological characteristics for practical application. Its usability as a universally applicable stand-alone instrument is demonstrated for surveying, recording RGB-coloured point clouds as well as delivering images for documentation and visualisation. Because of its limited range (10m without reflector and 150 m to reflector prisms) and low range accuracy (ca. 2 cm to 3 cm) compared to present-day total stations and laser scanners, the practical usage of the 2D/3D total station is currently limited to acquisition of accidents, forensic purpuses, speleology or facility management, as well as architectural recordings with low requirements regarding accuracy. However, the author is convinced that in the near future advancements in 3D camera technology will allow this type of comparatively low cost instrument to replace the total station as well as the laser scanner in an increasing number of areas.

  14. Dehumanization increases instrumental violence, but not moral violence

    Science.gov (United States)

    Rai, Tage S.; Valdesolo, Piercarlo; Graham, Jesse

    2017-01-01

    Across five experiments, we show that dehumanization—the act of perceiving victims as not completely human—increases instrumental, but not moral, violence. In attitude surveys, ascribing reduced capacities for cognitive, experiential, and emotional states to victims predicted support for practices where victims are harmed to achieve instrumental goals, including sweatshop labor, animal experimentation, and drone strikes that result in civilian casualties, but not practices where harm is perceived as morally righteous, including capital punishment, killing in war, and drone strikes that kill terrorists. In vignette experiments, using dehumanizing compared with humanizing language increased participants’ willingness to harm strangers for money, but not participants’ willingness to harm strangers for their immoral behavior. Participants also spontaneously dehumanized strangers when they imagined harming them for money, but not when they imagined harming them for their immoral behavior. Finally, participants humanized strangers who were low in humanity if they imagined harming them for immoral behavior, but not money, suggesting that morally motivated perpetrators may humanize victims to justify violence against them. Our findings indicate that dehumanization enables violence that perpetrators see as unethical, but instrumentally beneficial. In contrast, dehumanization does not contribute to moral violence because morally motivated perpetrators wish to harm complete human beings who are capable of deserving blame, experiencing suffering, and understanding its meaning. PMID:28739935

  15. Dehumanization increases instrumental violence, but not moral violence.

    Science.gov (United States)

    Rai, Tage S; Valdesolo, Piercarlo; Graham, Jesse

    2017-08-08

    Across five experiments, we show that dehumanization-the act of perceiving victims as not completely human-increases instrumental, but not moral, violence. In attitude surveys, ascribing reduced capacities for cognitive, experiential, and emotional states to victims predicted support for practices where victims are harmed to achieve instrumental goals, including sweatshop labor, animal experimentation, and drone strikes that result in civilian casualties, but not practices where harm is perceived as morally righteous, including capital punishment, killing in war, and drone strikes that kill terrorists. In vignette experiments, using dehumanizing compared with humanizing language increased participants' willingness to harm strangers for money, but not participants' willingness to harm strangers for their immoral behavior. Participants also spontaneously dehumanized strangers when they imagined harming them for money, but not when they imagined harming them for their immoral behavior. Finally, participants humanized strangers who were low in humanity if they imagined harming them for immoral behavior, but not money, suggesting that morally motivated perpetrators may humanize victims to justify violence against them. Our findings indicate that dehumanization enables violence that perpetrators see as unethical, but instrumentally beneficial. In contrast, dehumanization does not contribute to moral violence because morally motivated perpetrators wish to harm complete human beings who are capable of deserving blame, experiencing suffering, and understanding its meaning.

  16. Liquid scintillation spectrometer survey 155Eu liquid activity

    International Nuclear Information System (INIS)

    Zhang Zuhua

    2002-01-01

    In the countrywide contrasting survey of 155 Eu activity, 155 Eu liquid activity was determined for the first time through using liquid scintillation spectrometer survey 155 Eu β ray. In survey total uncertainty, determining activity accord with determining activity average value of all a wide variety of survey instrument entering into contrasting survey. But using liquid scintillation spectrometer survey, it is simple and save time, is beyond compare for other survey method. It indicate liquid scintillation spectrometer survey β-γ nuclide activity is effective as well

  17. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  18. Market Research Survey of Commercial Off-The-Shelf (COTS) Portable MS Systems for IAEA Safeguards Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Garret L.; Hager, George J.; Barinaga, Charles J.; Duckworth, Douglas C.

    2013-02-01

    This report summarizes the results for the market research survey of mass spectrometers that are deemed pertinent to International Atomic Energy Agency (IAEA) needs and strategic objectives. The focus of the report is on MS instruments that represent currently available (or soon to be) commercial off-the shelf (COTS) technology and weigh less than 400 pounds. A compilation of all available MS instruments (36 COTS and 2 R&D) is presented, along with pertinent information regarding each instrument.

  19. Trace Gas Retrievals from the GeoTASO Aircraft Instrument

    Science.gov (United States)

    Nowlan, C. R.; Liu, X.; Leitch, J. W.; Liu, C.; Gonzalez Abad, G.; Chance, K.; Cole, J.; Delker, T.; Good, W. S.; Murcray, F.; Ruppert, L.; Soo, D.; Loughner, C.; Follette-Cook, M. B.; Janz, S. J.; Kowalewski, M. G.; Pickering, K. E.; Zoogman, P.; Al-Saadi, J. A.

    2015-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is a passive remote sensing instrument capable of making 2-D measurements of trace gases and aerosols from aircraft. The instrument measures backscattered UV and visible radiation, allowing the retrieval of trace gas amounts below the aircraft at horizontal resolutions on the order of 250 m x 250 m. GeoTASO was originally developed under NASA's Instrument Incubator Program as a test-bed instrument for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey mission, and is now also part of risk reduction for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) and Geostationary Environment Monitoring Spectrometer (GEMS) geostationary satellite missions. We present spatially resolved observations of ozone, nitrogen dioxide, formaldehyde and sulfur dioxide over urban areas and power plants from flights during the DISCOVER-AQ field campaigns in Texas and Colorado, as well as comparisons with observations made by ground-based Pandora spectrometers, in situ monitoring instruments and other aircraft instruments deployed during these campaigns. These measurements at various times of day are providing a very useful data set for testing and improving TEMPO and GEMS retrieval algorithms, as well as demonstrating prototype validation strategies.

  20. Spectrometric aerial survey as a new tool for geological survey and mining prospecting

    International Nuclear Information System (INIS)

    Cambon, R.

    1997-01-01

    Airborne survey for radioactive minerals started around 1945. The limited sensitivity of the tools used, the difficulties found for the topographic and training effect corrections, made difficult the evaluation of the results. The technical progresses realized in the recent past years in electronic and computer sciences allowed to overcome these difficulties and gave to the method all its potentialities. With the aerial spectrometric survey, a new step was made, because this method can be used for other topics than radioactive prospection such as geological survey and mining prospection for metallic and industrial minerals. The spectrometric method is based on the possibility to measure photopeak energies (gamma radiation) emitted by radioactive minerals and discriminate between them those emitted by U238, TI 208 and K40 respectively daughter products of uranium, thorium and potassium. For airborne survey, one consider that measuring instruments will allow to pick-up 80% of the radioactive emission concerning the first 15 to 30 centimetres of ground (1 metre maximum). The use of this method for geological and mineral exploration is based on the assumption that different rock types or ore bearing rock types are composed of certain amounts of rock forming minerals which comprise specific quantities of radioactive elements such as potassium, uranium and thorium (cf: Gabelman 77). To be able to evaluate the results of the spectrometric survey it will be necessary to know roughly the behaviour of the different radioactive elements through a complete geological cycle. (author)

  1. Results from an International Survey

    OpenAIRE

    Kawase, Kazumi; Carpelan-Holmstrom, Monika; Kwong, Ava; Sanfey, Hilary

    2016-01-01

    Compared with male surgeons, women have less success advancing their careers and are underrepresented in leadership positions in surgery. The purpose of this study is to identify the qualifications necessary to become leaders in surgery and the career barriers faced by women surgeons in various cultural environments. A survey was performed with women surgeons in Japan, USA, Finland, and Hong Kong, China, to assess various barriers faced by women surgeons in the respective countries. To develo...

  2. Results of the radiological survey at Two Mile Creek, Tonawanda, New York (TNY002)

    International Nuclear Information System (INIS)

    Murray, M.E.; Rodriguez, R.E.; Uziel, M.S.

    1997-08-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at Two Mile Creek, Tonawanda, New York. The survey was performed in November 1991 and May 1996. The purpose of the survey was to determine if radioactive materials from work performed under government contract at the Linde Air Products Division of Union Carbide Corporation, Tonawanda, New York, had been transported into the creek. The survey included a surface gamma scan in accessible areas near the creek and the collection of soil, sediment, and core samples for radionuclide analyses. Survey results indicate that no significant material originating at the Linde plant is presently in the creek. Three of the 1991 soil sample locations on the creek bank and one near the lake contained slightly elevated concentrations of 238 U with radionuclide distributions similar to that found in materials resulting from former processing activities at the Linde site

  3. Survey sustainability Biomass. Appendix. Results of the international respondents

    Energy Technology Data Exchange (ETDEWEB)

    Bergsma, G.C.; Groot, M.I.

    2006-06-15

    As part of an array of strategies to combat climate change, biomass is being used increasingly as a substitute for fossil fuels. It is important that the sustainability benefits thus accruing to the Netherlands are not at the expense of sustainable development in producer countries. Against this background the 'Sustainable biomass imports' project group is developing a set of criteria for evaluating the sustainability of biomass projects. To assess support for such criteria, CE conducted an internet survey among the various stakeholders (NGOs, industry, government), drawing a total of 104 responses. This report presents all the results and conclusions of the survey, for each category of stakeholders and overall. Among the most striking conclusions are the following: The majority of respondents see a sustainability audit on biomass as feasible, provided the sustainability criteria are adequate for the purpose (68%); Almost all the respondents are of the opinion that such sustainability criteria should apply to all applications of biomass (90%); On the issue of whether these criteria should vary according to the producer region concerned, respondents were divided (50% for, 50% against); Many NGOs state there should be different sustainability criteria in force for different biomass flows (50%), in contrast to industry, which argues for a uniform set of criteria for all flows; Most respondents hold that any biomass criteria should apply to both subsidised and unsubsidised projects; At the same time, a sizable majority of respondents state that subsidisation of biomass projects should depend on the degree of sustainability (72%) and in particular on the CO2 emission cuts achieved, this being regarded as the single most important factor; When it comes to the issue of GMO, opinions differ markedly between NGOs and industry, with some 75% of NGOs wanting this aspect included, but only 10% of industry; Respondents also commented on a number of additional issues

  4. Advanced Technologies and Instrumentation at the National Science Foundation

    Science.gov (United States)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  5. Risk perception in the public: Results of a survey

    International Nuclear Information System (INIS)

    Bastide, S.; Brenot, J.

    1989-01-01

    At first, some approaches used to study risk perception are briefly reviewed. Then, results of a survey devoted to general public risk perception, are presented. Risky activities are ranked. Clusters of activities which are judged similar for danger, are given. The relations between perception of danger, trust in the safety organization and the characteristics of the interviewed people are emphasized. The nuclear and chemical sectors are shortly compared. (author)

  6. Seismic refraction profile, Kingdom of Saudi Arabia: field operations, instrumentation, and initial results

    Science.gov (United States)

    Blank, H. Richard; Healy, J.H.; Roller, John; Lamson, Ralph; Fisher, Fred; McClearn, Robert; Allen, Steve

    1979-01-01

    In February 1978 a seismic deep-refraction profile was recorded by the USGS along a 1000-km line across the Arabian Shield in western Saudi Arabia. The line begins in Paleozoic and Mesozoic cover rocks near Riyadh on the Arabian Platform, leads southwesterly across three major Precambrian tectonic provinces, traverses Cenozoic rocks of the coastal plain near Jizan (Tihamat Asir), and terminates at the outer edge of the Farasan Bank in the southern Red Sea. More than 500 surveyed recording sites were occupied, including 19 in the Farasan Islands. Six shot points were used--five on land, with charges placed mostly below water table in drill holes, and one at sea, with charges placed on the sea floor and fired from a ship. The total charge consumed was slightly in excess of 61 metric tons in 21 discrete firings. Seismic energy was recorded by means of a set of 100 newly developed portable seismic stations. Each station consists of a standard 2-Hz vertical geophone coupled to a self-contained analog recording instrument equipped with a magnetic-tape cassette. The stations were deployed in groups of 20 by five observer teams, each generally consisting of two scientist-technicians and a surveyor-guide. On the day prior to deployment, the instruments were calibrated and programmed for automatic operation by means of a specially designed device called a hand-held tester. At each of ten pre-selected recording time windows on a designated firing day, the instruments were programmed to turn on, stabilize, record internal calibration signals, record the seismic signals at three levels of amplification, and then deactivate. After the final window in the firing sequence, all instruments were retrieved and their data tapes removed for processing. A specially designed, field tape- dubbing system was utilized at shot point camps to organize and edit data recorded on the cassette tapes. The main functions of this system are to concatenate all data from each shot on any given day

  7. Immersion freezing by SnomaxTM particles: Comparison of results from different instruments

    Science.gov (United States)

    Wex, Heike; Stratmann, Frank; Rösch, Michael; Niedermeier, Dennis; Nilius, Björn; Möhler, Ottmar; Mitra, Subir K.; Koop, Thomas; Jantsch, Evelyn; Hiranuma, Naruki; Diehl, Karoline; Curtius, Joachim; Budke, Carsten; Boose, Yvonne; Augustin, Stefanie

    2014-05-01

    Within the DFG funded research unit INUIT (Ice Nucleation research UnIT, FOR 1525), an effort was made to compare results on immersion freezing from a suite of different instruments. Besides mineral dusts, SnomaxTM was picked as one of the substances that were examined by all participating groups. Here, the comparison of the results for SnomaxTM is presented. Every participating group used SnomaxTM from the same batch and, as far as possible, the same particle generation set-up. Instruments participating in the comparison were, in alphabetical order, an acoustic levitator (Diehl et al., 2009), AIDA (Connolly et al., 2009), BINARY (Budke et al., 2013), FINCH (Bundke et al., 2008), LACIS (Hartmann et al., 2011), PINC (Chou et al., 2011) and the Mainz vertical windtunnel (Diehl et al., 2011). Some of the instruments examined droplets directly produced from SnomaxTM suspensions, where the suspensions could have a wide range of concentrations. Other instruments used size segregated particles which were generated via atomization from a SnomaxTM suspension and subsequent drying, followed by size selection with a DMA (Differential Mobility Analyzer). These particles were then activated to droplets and cooled subsequently. For these, the number of ice nucleation active protein complexes present in the droplets depended on the original particle size (for details see e.g. Hartmann et al., 2013). Also, the different measurements spanned a range of different time scales. The shortest residence time of roughly 1 second was used for LACIS measurements, and the longest one was about 6 seconds used in the BINARY setup with a cooling rate of 1 K/min. All data were evaluated using two different approaches: 1) a time dependent approach following Classical Nucleation Theory which included the use of a contact angle distribution (see Niedermeier et al., 2014); 2) a singular approach using an active site density per mass (see Vali, 1971, Murray et al., 2012). Both approaches were found

  8. RESULTS OF SURGICAL TREATMENT OF INFANTILE AND JUVENILE SCOLIOSIS USING VARIOUS INSTRUMENTATION

    Directory of Open Access Journals (Sweden)

    M. V. Mikhailovsky

    2015-01-01

    Full Text Available Introduction. The analysis Results of surgical treatment of growing children with infantile and juvenile scoliosis (IS can the optimal method of treatment select. In young children with significant growth potential spinal fusion may not be the best option as it limits further longitudinal growth of the spine and may to the thoracic insufficiency syndrome result. To address this problem recently several techniques focused, their have advantages and drawbacks.Material and methods. Since 2008 year 127 patients (64 girls, 63 boys aged (4.5 ± 2.1 years were operated on. In group I 65 patients were operated on using VEPTR (Vertical Expandable Prosthetic Titanium Rib instrumentation, in group II 42 patients using various spinal instrumentation. 20 patients with congenital kyphosis were excluded. The average follow-up time was (5.6 ± 1.1 years.Results. In group I average value of the primary scoliotic curve before surgery was (74.7 ± 22.9, secondary curve (42.8 ± 16.0, thoracic kyphosis (46.3 ± 27.4, lumbar lordosis (54.6 ± 14. Average value of the primary scoliotic curve after surgery was reduced to (51 ± 20 (correction 31.7%, at followup to (56.5 ± 18.5, secondary curve (31.8 ± 12.8 (25.7%, at follow-up to (32.4 ± 18.4, thoracic kyphosis (36.8 ± 20.8 (20,5%, at follow-up to (41.8 ± 21.0, lumbar lordosis (45.4 ± 12.7 (16,9%, at follow-up to (48.2 ± 11.7 (p < 0.05. Space available for lung before surgery was (84.5 ± 8.7 %, after surgery was (94.8 ± 6.7%, at follow-up increased to (98.6 ± 5.4 % (p < 0.05. Complications included 11 implant dislocations and 1 infection. In group II average value of the primary scoliotic curve before surgery was (87.6 ± 6.6, secondary curve (47.8 ± 4.6, thoracic kyphosis (61.4 ± 10.4, lumbar lordosis (61.8 ± 4.9. Average value of the primary scoliotic curve after surgery was reduced to 50.6 ± 5.3 (correction 42.3%, at follow-up to (66.1 ± 6.3

  9. Results From the 2014 National Wilderness Manager Survey

    Science.gov (United States)

    Ramesh Ghimire; Ken Cordell; Alan Watson; Chad Dawson; Gary T. Green

    2015-01-01

    A national survey of managers was developed to support interagency wilderness strategic planning. The focus was on major challenges, perceived needs for science and training, and accomplishments of 1995 Strategic Plan objectives. The survey was administered to managers at the four federal agencies with wilderness management responsibilities: the Bureau of Land...

  10. Increased Science Instrumentation Funding Strengthens Mars Program

    Science.gov (United States)

    Graham, Lee D.; Graff, T. G.

    2012-01-01

    As the strategic knowledge gaps mature for the exploration of Mars, Mars sample return (MSR), and Phobos/Deimos missions, one approach that becomes more probable involves smaller science instrumentation and integrated science suites. Recent technological advances provide the foundation for a significant evolution of instrumentation; however, the funding support is currently too small to fully utilize these advances. We propose that an increase in funding for instrumentation development occur in the near-term so that these foundational technologies can be applied. These instruments would directly address the significant knowledge gaps for humans to Mars orbit, humans to the Martian surface, and humans to Phobos/ Deimos. They would also address the topics covered by the Decadal Survey and the Mars scientific goals, objectives, investigations and priorities as stated by the MEPAG. We argue that an increase of science instrumentation funding would be of great benefit to the Mars program as well as the potential for human exploration of the Mars system. If the total non-Earth-related planetary science instrumentation budget were increased 100% it would not add an appreciable amount to the overall NASA budget and would provide the real potential for future breakthroughs. If such an approach were implemented in the near-term, NASA would benefit greatly in terms of science knowledge of the Mars, Phobos/Deimos system, exploration risk mitigation, technology development, and public interest.

  11. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  12. Cavity Attenuated Phase Shift (CAPS) Method for Airborne Aerosol Light Extinction Measurement: Instrument Validation and First Results from Field Deployment

    Science.gov (United States)

    Petzold, A.; Perim de Faria, J.; Berg, M.; Bundke, U.; Freedman, A.

    2015-12-01

    Monitoring the direct impact of aerosol particles on climate requires the continuous measurement of aerosol optical parameters like the aerosol extinction coefficient on a regular basis. Remote sensing and ground-based networks are well in place (e.g., AERONET, ACTRIS), whereas the regular in situ measurement of vertical profiles of atmospheric aerosol optical properties remains still an important challenge in quantifying climate change. The European Research Infrastructure IAGOS (In-service Aircraft for a Global Observing System; www.iagos.org) responds to the increasing requests for long-term, routine in situ observational data by using commercial passenger aircraft as measurement platform. However, scientific instrumentation for the measurement of atmospheric constituents requires major modifications before being deployable aboard in-service passenger aircraft. Recently, a compact and robust family of optical instruments based on the cavity attenuated phase shift (CAPS) technique has become available for measuring aerosol light extinction. While this technique was successfully deployed for ground-based atmospheric measurements under various conditions, its suitability for operation aboard aircraft in the free and upper free troposphere still has to be demonstrated. In this work, the modifications of a CAPS PMex instrument for measuring aerosol light extinction on aircraft, the results from subsequent laboratory tests for evaluating the modified instrument prototype, and first results from a field deployment aboard a research aircraft will be covered. In laboratory studies, the instrument showed excellent agreement (deviation CAPS PMex instrument response within 10% deviation. During the field deployment, aerosol extinction coefficients and associated aerosol size distributions have been measured and will be presented as comparison studies between measured and calculated data.

  13. Results of instrumented posterolateral fusion in treatment of lumbar spondylolisthesis with and without segmental kyphosis: A retrospective investigation

    Directory of Open Access Journals (Sweden)

    Szu-Yuan Chen

    2015-06-01

    Full Text Available Background: Treatment by posterolateral fusion (PLF with pedicle-screw instrumentation can be unsuccessful in one-segment and low-grade lumbar spondylolisthesis. Segmental kyphosis, either rigid or dynamic, was hypothesized to be one of the factors interfering with the fusion results. Methods: From 2004 to 2005, 239 patients with single-segment and low-grade spondylolisthesis were recruited and divided into two groups: Group 1 consisting of 129 patients without segmental kyphosis and group 2 consisting of 110 patients with segmental kyphosis. All patients underwent instrumented PLF at the same medical institute, and the average follow-up period was 31 ± 19 months. We obtained plain radiographs of the lumbosacral spine with the anteroposterior view, the lateral view, and the dynamic flexion-extension views before the operation and during the follow-ups. The results of PLF in the two groups were then compared. Results: There was no significant difference in the demographic data of the two groups, except for gender distribution. The osseous fusion rates were 90.7% in group 1 and 68.2% in group 2 (p < 0.001. Conclusion: Instrumented PLF resulted in significantly higher osseous fusion rate in patients without segmental kyphosis than in the patients with segmental kyphosis. For the patients with sagittal imbalance, such as rigid or dynamic kyphosis, pedicle-screw fixation cannot ensure successful PLF. Interbody fusion by the posterior lumbar interbody fusion or transforaminal lumbar interbody fusion technique might help overcome this problem.

  14. Implementation Of Carlson Survey Software2009 In Survey Works And Comparison With CDS Software

    Directory of Open Access Journals (Sweden)

    Mohamed Faraj EL Megrahi

    2017-02-01

    Full Text Available The automation surveying is one of the most influential changes to surveying concept and profession has had to go through, this has taken effect in two major courses, hardware (instrumentation used in data collection and presentation, and the software (the applications used in data processing and manipulation. Automation is majorly computer based and just like all such systems is subject to improvement often; this is manifested in the new kinds of instrumentation models every few years such as total station and newer versions of software’s. The software that has the potential to completely affect survey automation is Carlson Surveying Software. This when coupled with total station as data processing and collection methods respectively; is capable of greatly improving productivity while reducing time and cost required in the long run. However, it is only natural for users to desire a competent software and be able to choose from what is available on the market based on guided research and credible information from previous researches. Such studies not only help in choice of software but are also handy when it comes to testing approaches and recommending improvements based on advantages and disadvantages to the manufacturers to help in advancement in the software industry for better and more comfortable use. The expected outcome of the research is a successful implementation of Carlson survey 2009 software in survey works and a comparison with other existing software like Civil Design Software (CDS was highlighted its advantages and disadvantages.

  15. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  16. Radiation protection commissioning of neutron beam instruments at the OPAL research reactor

    International Nuclear Information System (INIS)

    Parkes, Alison; Saratsopoulos, John; Deura, Michael; Kenny, Pat

    2008-01-01

    The neutron beam facilities at the 20 MW OPAL Research Reactor were commissioned in 2007 and 2008. The initial suite of eight neutron beam instruments on two thermal neutron guides, two cold neutron guides and one thermal beam port located at the reactor face, together with their associated shielding were progressively installed and commissioned according to their individual project plans. Radiation surveys were systematically conducted as reactor power was raised in a step-wise manner to 20 MW in order to validate instrument shielding design and performance. The performance of each neutron guide was assessed by neutron energy spectrum and flux measurements. The activation of beam line components, decay times assessments and access procedures for Bragg Institute beam instrument scientists were established. The multiple configurations for each instrument and the influence of operating more than one instrument or beamline simultaneously were also tested. Areas of interest were the shielding around the secondary shutters, guide shield and bunker shield interfaces and monochromator doors. The shielding performance, safety interlock checks, improvements, radiation exposures and related radiation protection challenges are discussed. This paper discusses the health physics experience of commissioning the OPAL Research Reactor neutron beam facilities and describes health physics results, actions taken and lessons learned during commissioning. (author)

  17. Moving beyond Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…

  18. Yoga in Australia: Results of a national survey.

    Science.gov (United States)

    Penman, Stephen; Cohen, Marc; Stevens, Philip; Jackson, Sue

    2012-07-01

    The therapeutic benefits of yoga and meditation are well documented, yet little is known about the practice of yoga in Australia or elsewhere, whether as a physical activity, a form of therapy, a spiritual path or a lifestyle. To investigate the practice of yoga in Australia, a national survey of yoga practitioners was conducted utilizing a comprehensive web-based questionnaire. Respondents were self-selecting to participate. A total of 3,892 respondents completed the survey. Sixty overseas respondents and 1265 yoga teachers (to be reported separately) were excluded, leaving 2,567 yoga practitioner respondents. The typical yoga survey respondent was a 41-year-old, tertiary educated, employed, health-conscious female (85% women). Asana (postures) and vinyasa (sequences of postures) represented 61% of the time spent practicing, with the other 39% devoted to the gentler practices of relaxation, pranayama (breathing techniques), meditation and instruction. Respondents commonly started practicing yoga for health and fitness but often continued practicing for stress management. One in five respondents practiced yoga for a specific health or medical reason which was seen to be improved by yoga practice. Of these, more people used yoga for stress management and anxiety than back, neck or shoulder problems, suggesting that mental health may be the primary health-related motivation for practicing yoga. Healthy lifestyle choices were seen to be more prevalent in respondents with more years of practice. Yoga-related injuries occurring under supervision in the previous 12 months were low at 2.4% of respondents. Yoga practice was seen to assist in the management of specific health issues and medical conditions. Regular yoga practice may also exert a healthy lifestyle effect including vegetarianism, non-smoking, reduced alcohol consumption, increased exercise and reduced stress with resulting cost benefits to the community.

  19. National Survey Results: Retention of Women in Collegiate Aviation

    Science.gov (United States)

    Turney, Mary Ann; Bishop, James C.; Karp, Merrill R.; Niemczyk, Mary; Sitler, Ruth L.; Green, Mavis F.

    2002-01-01

    Since the numbers of women pursuing technical careers in aviation continues to remain very low, a study on retention of women was undertaken by a team of university faculty from Embry Riddle Aeronautical University, Arizona State University, and Kent State University. The study was initiated to discover the factors that influence women once they have already selected an aviation career and to ascertain what could be done to support those women who have demonstrated a serious interest in an aviation career by enrolling in a collegiate aviation program. This paper reports preliminary results of data collected in the first and second years of the study. The data was collected from surveys of 390 college students (195 women and 195 men) majoring in aviation programs in nine colleges and universities, representing widely varied geographic areas and including both two- and four-year institutions. Results revealed significant areas of concern among women in pilot training. When queried about these concerns, differences were evident in the responses of the male and female groups. These differences were expected. However, a surprising finding was that women in early stages of pilot training responded differently from women in more experienced stages, These response differences did not occur among the men surveyed. The results, therefore, suggest that women in experienced stages of training may have gone through an adaptation process and reflect more male-like attitudes about a number of objects, including social issues, confidence, family, and career.

  20. Survey Result for the Safety Culture Attitude of HANARO in 2008

    International Nuclear Information System (INIS)

    Wu, Jong Sup; An, Seok Hwa

    2009-01-01

    One of the important aims of a nuclear management system is to foster a strong safety culture. The safety culture activities for HANARO have been implemented and the importance of safety management in nuclear activities has also been emphasized since its first operation. HANARO developed its own safety culture indicators by referring to the IAEA's documents for the purpose of the evaluation of the safety culture attitude. In June 2008 a survey on the safety culture was conducted based on the new safety culture indicators. The result of the survey shows that the safety culture activities contribute positively to its safe operation. But it is necessary to encourage some activities like training, resources and organizational culture. The survey was helpful to understand the general trends of the safety attitudes and to set the safety culture activities necessary for the improvement of its safe operation

  1. The UV Survey Mission Concept, CETUS

    Science.gov (United States)

    Heap, Sara; and the CETUS Team

    2018-01-01

    In March 2017, NASA selected CETUS for study of a Probe-class mission concept. W. Danchi is the CETUS PI, and S. Heap is the Science PI. CETUS is primarily a UV survey telescope to complement survey telescopes of the 2020’s including E-ROSITA, Subaru Hyper Suprime Cam and Prime-Focus Spectrograph, WFIRST, and the Square Kilometer Array. CETUS comprises a 1.5-m wide-field telescope and three science instruments: a wide-field (1045” on a side) far-UV and near-UV camera; a similarly wide-field near-UV multi-object spectrograph utilizing a next-generation micro-shutter array; and a single-object spectrograph with options of spectral region (far-UV or near-UV) and spectral resolving power (2,000 or 40,000). The survey instruments will operate simultaneously thereby producing wide-field images in the near-UV and far-UV and a spectrogram containing near-UV spectra of up to 100 sources free of spectral overlap and astronomical background. ln concert with other survey telescopes, CETUS will focus on understanding galaxy evolution at cosmic noon (z~1-2).

  2. A quantitative preliminary evaluation of nuclear medicine instruments in the Philippines

    International Nuclear Information System (INIS)

    Valdezco, E.M.; Caseria, E.S.; Lopez, L.B.; Pasion, I.S.; Linilitan, V.E.

    1986-01-01

    This paper is the result of a survey conducted on several nuclear medicine centers in Metro Manila including one in Baguio City to assess the performance of nuclear medicine instruments and the extent of quality procedures being carried out. It was revealed that prompt and competent service seems to be a major problem. Of the eleven sites visited, 4 have cameras only, 4 with cameras with computers, 3 with rectilinear scanners only and 1 with cameras + rectilinear scanners. (ELC) 8 figs

  3. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2014-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions and the associated errors for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is the key to determining their imprint on the transfer function from the observed to the actual sky a...

  4. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions and the associated errors for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is the key to determining their imprint on the transfer function from the observed to the actual sky a...

  5. An assessment of self-reported physical activity instruments in young people for population surveillance: Project ALPHA

    Directory of Open Access Journals (Sweden)

    Pearson Natalie

    2011-01-01

    Full Text Available Abstract Background The assessment of physical activity is an essential part of understanding patterns and influences of behaviour, designing interventions, and undertaking population surveillance and monitoring, but it is particularly problematic when using self-report instruments with young people. This study reviewed available self-report physical activity instruments developed for use with children and adolescents to assess their suitability and feasibility for use in population surveillance systems, particularly in Europe. Methods Systematic searches and review, supplemented by expert panel assessment. Results Papers (n = 437 were assessed as potentially relevant; 89 physical activity measures were identified with 20 activity-based measures receiving detailed assessment. Three received support from the majority of the expert group: Physical Activity Questionnaire for Children/Adolescents (PAQ-C/PAQ-A, Youth Risk Behaviour Surveillance Survey (YRBS, and the Teen Health Survey. Conclusions Population surveillance of youth physical activity is strongly recommended and those involved in developing and undertaking this task should consider the three identified shortlisted instruments and evaluate their appropriateness for application within their national context. Further development and testing of measures suitable for population surveillance with young people is required.

  6. The psychometric properties of a shortened corporate entrepreneurship assessment instrument

    Directory of Open Access Journals (Sweden)

    Renier Steyn

    2017-08-01

    Aim: The aim of this research was to evaluate the psychometric properties of a measure of entrepreneurial climate. Entrepreneurial climate was measured using a shortened version of the Hornsby, Kuratko and Zahra (2002 instrument, called the Corporate Entrepreneurship Assessment Instrument (CEAI. Making information on the psychometric properties of the instrument available directly relates to its utility. Setting: The setting was medium to large South African companies. A random sample of employees was drawn from 53 selected companies across South Africa, with 60 respondents per company (N = 3 180. Methods: A cross-sectional survey design was used. Several instruments were administered, including the shortened version of the CEAI. Cronbach’s alpha was used to test for reliability and several methods were used to test for validity. Correlation analysis was used to test for concurrent validity, convergent validity and divergent validity. Principle component factor analysis was used to test for factorial validity and a t-test to test for known-group validity. Results: The results showed that the reliability for the total score of the shortened version of the CEAI was acceptable at 0.758. The results also showed some evidence of concurrent validity, as well as homogeneity among the items. With regard to factorial validity, all items loaded in accordance with the subscales of the instrument. The measure was able to distinguish, as expected, between government organisations and private business entities, suggesting known-group validity. Convergent validity and divergent validity were also assessed. Interesting to note was that entrepreneurship climate correlates more with general employee attitude (e.g. employee engagement; R= 0.420, p < 0.001 and organisational commitment, R = 0.331, p < 0.001 than with self-reported innovation (R = 0.277, p < 0.001 and R = 0.267, p < 0.001. Contribution: This paper not only provided information on the reliability

  7. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  8. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  9. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  10. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  11. A blood-result turn-around time survey to improve congenital ...

    African Journals Online (AJOL)

    The results of a turn-around time study of blood specimens for syphilis serology in antenatal clinic attenders between 19 rural clinics and their base hospital, including a follow-up survey to assess the impact of interventions, are described. The objective of the study was to detennine how long blood samples took to get.

  12. Epistemology and expectations survey about experimental physics: Development and initial results

    Directory of Open Access Journals (Sweden)

    Benjamin M. Zwickl

    2014-06-01

    Full Text Available In response to national calls to better align physics laboratory courses with the way physicists engage in research, we have developed an epistemology and expectations survey to assess how students perceive the nature of physics experiments in the contexts of laboratory courses and the professional research laboratory. The Colorado Learning Attitudes about Science Survey for Experimental Physics (E-CLASS evaluates students’ epistemology at the beginning and end of a semester. Students respond to paired questions about how they personally perceive doing experiments in laboratory courses and how they perceive an experimental physicist might respond regarding their research. Also, at the end of the semester, the E-CLASS assesses a third dimension of laboratory instruction, students’ reflections on their course’s expectations for earning a good grade. By basing survey statements on widely embraced learning goals and common critiques of teaching labs, the E-CLASS serves as an assessment tool for lab courses across the undergraduate curriculum and as a tool for physics education research. We present the development, evidence of validation, and initial formative assessment results from a sample that includes 45 classes at 20 institutions. We also discuss feedback from instructors and reflect on the challenges of large-scale online administration and distribution of results.

  13. French parapetroleum industry: results of 1992 survey

    International Nuclear Information System (INIS)

    Valentin, E.; Trouve, O.

    1992-01-01

    The petroleum prospection and production industries have developed a parapetroleum sector that is considerable in size and has been going through profound changes over the past few years. Under the impetus of acquisitions and mergers, the supply has become heavily concentrated, and now reorganized around a growing demand for integrated services. Petroleum companies tend to farm out a growing portion of their business, and this sharing out of competence and sometimes of responsibilities is breeding new types of partnership arrangements between the petroleum and parapetroleum business. This paper gives the results of an survey led in 1991 on petroleum international economy and gives statistical informations on french parapetroleum industry (exploration-production investments, exploratory wells drilled, drilling equipment in action, offshore operations, turnover evolution, shortage of manpower). 14 figs., 5 tabs

  14. Defining Innovation in Neurosurgery: Results from an International Survey.

    Science.gov (United States)

    Zaki, Mark M; Cote, David J; Muskens, Ivo S; Smith, Timothy R; Broekman, Marike L

    2018-06-01

    Innovation is a part of the daily practice of neurosurgery. However, a clear definition of what constitutes innovation is lacking and opinions vary from continent to continent, from hospital to hospital, and from surgeon to surgeon. In this study, we distributed an online survey to neurosurgeons from multiple countries to investigate what neurosurgeons consider innovative, by gathering opinions on several hypothetical cases. The anonymous survey consisted of 52 questions and took approximately 10 minutes to complete. A total of 355 neurosurgeons across all continents excluding Antarctica completed the survey. Neurosurgeons achieved consensus (>75%) in considering specific cases to be innovative, including laser resection of meningioma, focused ultrasonography for tumor, oncolytic virus, deep brain stimulation for addiction, and photodynamic therapy for tumor. Although the new dura substitute case was not considered innovative, there was consensus among neurosurgeons indicating that institutional review board approval was still necessary to maintain ethical standards. Furthermore, although 90% of neurosurgeons considered an oncolytic virus for glioblastoma multiforme to be innovative, only 78% believed that institutional review board approval was necessary before treatment. Our results indicate that innovation is a heterogeneous concept among neurosurgeons that necessitates standardization to ensure appropriate patient safety without stifling progress. We discuss both the ethical drawbacks of not having a clear definition of innovation and the challenges in achieving a unified understanding of innovation in neurosurgery and offer suggestions for uniting the field. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Validity of instruments to assess students' travel and pedestrian safety

    Directory of Open Access Journals (Sweden)

    Baranowski Tom

    2010-05-01

    Full Text Available Abstract Background Safe Routes to School (SRTS programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Methods Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI and intraclass correlations (ICC across research assistant ratings. Results The SRTS travel survey had high test-retest reliability (κ = 0.97, n = 96, p Conclusions These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work.

  16. Risk perception and benefits perception. Survey results and discussion

    International Nuclear Information System (INIS)

    Touzet, R.; Remedi, J.; Baron, J.; Caspani, C.

    2000-01-01

    The fact that the risks deriving from different activities involving the same radiation exposure are seen very differently by a single population is a highly significant one. Exactly identical risks are considered oppositely, depending on the origin of radiation (whether produced by medical applications or by nuclear power plants, resulting from natural radiation or from artificial radiation). It appears as if there was good radiation and bad radiation..! One of the purposes of the paper is the discussion of causes. The acceptance of a given risk by a certain section of the population is closely related to the benefits that the group expects to receive-either consciously or unconsciously-from the activity producing the risk. Consequently, an analysis of the factors influencing the eventual rejection of a practice should explore not only fears, but also hopes...! On the basis of a risk-perception survey carried out in a population sector attending hospitals-including both patients and physicians-, a prior objective analysis of the results obtained was performed and, later on, the various statements by those surveyed were studied. The design of the survey allowed for a comparative assessment of the perception of different risks depending on the people's educational and social level. An epistemological study was made on the validity involved in the use of the data resulting from the survey, so as to reach different conclusions. The population's opinion about the capacity for response, the qualification and the mitigation means available to the State authorities in order to face an eventual radiological emergency plays a leading role in risk perception. In an analysis of the relevant factors involved in risk and benefits perception by the population (in the real world), attention must be paid to the existence of organized opinion groups representing the interest of a given sector. Of course, the population's confidence in the experts providing the information is a key

  17. The Electron Drift Instrument on Cluster: overview of first results

    Directory of Open Access Journals (Sweden)

    G. Paschmann

    Full Text Available EDI measures the drift velocity of artificially injected electron beams. From this drift velocity, the perpendicular electric field and the local magnetic field gradients can be deduced when employing different electron energies. The technique requires the injection of two electron beams at right angles to the magnetic field and the search for those directions within the plane that return the beams to their associated detectors after one or more gyrations. The drift velocity is then derived from the directions of the two beams and/or from the difference in their times-of-flight, measured via amplitude-modulation and coding of the emitted electron beams and correlation with the signal from the returning electrons. After careful adjustment of the control parameters, the beam recognition algorithms, and the onboard magnetometer calibrations during the commissioning phase, EDI is providing excellent data over a wide range of conditions. In this paper, we present first results in a variety of regions ranging from the polar cap, across the magnetopause, and well into the magnetosheath.

    Key words. Electron drift velocity (electric fields; plasma convection; instruments and techniques

  18. Preventing intentional food contamination: a survey to assess restaurant preparedness.

    Science.gov (United States)

    Xirasagar, Sudha; Kanwat, C P; Qu, Haiyan; Smith, Lillian U; Patterson, Nathaniel J; Shewchuk, Richard M

    2010-01-01

    In the age of preparedness, public health agencies are concerned with intentional acts of food contamination in restaurants, in addition to food safety. Food safety consists of applying standard norms of practice and infrastructure, which, if violated, cause food-borne illness. In contrast, food defense requires an institutionalized mindset of informed alertness to unusual variations from the norms, combined with preemptive practices best suited to each restaurant. Therefore, while food safety lends itself to regulation to ensure standard practices, food defense is best served by advisory guidelines for autonomous application, preserving the restaurant industry's core values of hospitality and customer service. To address this challenge, public health agencies need survey tools that can yield action-relevant data on the knowledge and practice gaps in food defense preparedness and on educational messages and support services to be developed for maximum impact potential. This article presents a mail survey instrument, developed using qualitative research to ensure content and face validity. Instrument development involved drafting the survey on the basis of expert consultations, validating its content by using focus groups (representing all restaurant categories and geographic regions), and ensuring face validity through cognitive interviews. The resulting survey remains sensitive to the hospitality industry while encompassing all vulnerable points.

  19. A Danish survey of spinal cord stimulation baseline data: First results from a national neuromodulation database

    DEFF Research Database (Denmark)

    Meier, Kaare; Scherer, Christian; Rosenlund, Christina

    A Danish survey of spinal cord stimulation baseline data: First results from a national neuromodulation database......A Danish survey of spinal cord stimulation baseline data: First results from a national neuromodulation database...

  20. Radon in workplaces: First results of an extensive survey and comparison with radon in homes

    International Nuclear Information System (INIS)

    Bucci, S.; Pratesi, G.; Viti, M. L.; Pantani, M.; Bochicchio, F.; Venoso, G.

    2011-01-01

    Extensive radon surveys have been carried out in many countries only in dwellings, whereas surveys in workplaces are rather sparse and generally restricted to specific workplaces/activities, e.g. schools, spas and caves. Moreover, radon-prone areas are generally defined on the basis of radon surveys in dwellings, while radon regulations use this concept to introduce specific requirements in workplaces in such areas. This approach does not take into account that work activities and workplace characteristics can significantly affect radon concentration. Therefore, an extensive survey on radon in different workplaces have been carried out in a large region of Italy (Tuscany), in order to evaluate radon distribution in workplaces over the whole territory and to identify activities and workplace characteristics affecting radon concentration. The results of this extensive survey are compared with the results of the survey carried out in dwellings in the same period. The workplaces monitored were randomly selected among the main work activities in the region, including both public and industrial buildings. The survey monitored over 3500 rooms in more than 1200 buildings for two consecutive periods of ∼6 months. Radon concentration was measured by means of passive nuclear track detectors. (authors)

  1. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  2. Satisfaction measurement instruments for healthcare service users: a systematic review

    OpenAIRE

    Almeida, Renato Santos de; Bourliataux-Lajoinie, Stephane; Martins, Mônica

    2015-01-01

    Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND...

  3. Survey Research: Methods, Issues and the Future

    Science.gov (United States)

    Brewer, Ernest W.; Torrisi-Steele, Geraldine; Wang, Victor C. X.

    2015-01-01

    Survey research is prevalent among many professional fields. Both cost effective and time efficient, this method of research is commonly used for the purposes of gaining insight into the attitudes, thoughts, and opinions of populations. Additionally, because there are several types of survey research designs and data collection instruments, the…

  4. Preliminary Results of the VLFE Quadrupole Instrumentation From The PARX Sounding Rocket

    Science.gov (United States)

    Reinleitner, L. A.; Holzworth, R. H.; Meadows, A. L.

    2003-12-01

    The NASA Pulsating Auroral Rocket eXperiment (PARX - March '97 from Poker Flat, AK) was equipped with 4 electric field probes oriented (X and Y) perpendicular to the ambient magnetic field, and one probe (along the Z axis) to obtain the parallel electric field. The rocket also included a three-axis VLF search coil magnetometer. The VLF measurements for both instruments were from 100 Hz - 8 KHz. Additionally, the electric field information was used onboard the rocket to obtain the "quadrupole" electric field, defined to be {(V1+V2) - (V3+V4)}/2d, which shows significant response only to short wavelength waves. This instrumentation clearly shows the long wavelength nature of features tentatively described as auroral hiss, and the shorter wavelength nature of the electrostatic and/or quasi-electrostatic waves.

  5. Nuclear instrumentation for uranium exploration

    International Nuclear Information System (INIS)

    Sarma, Ch. V.N.; Sarma, C.V.R.; Sreehari, R.

    1999-01-01

    Instrumentation required for uranium exploration may be broadly classified based on surface and sub-surface measurement of gamma-ray intensity. Surface measurement of gross and spectral gamma intensity are carried out by employing portable Geiger Mueller/scintillation counters and four-channel spectrometers. Measurement of thoron ( 220 Rn) and radon ( 222 Rn) in the soil gas is being carried out by closed circuit technique using radon measuring system. Radiometric mapping of trenches, pits and mine-faces are carried out using shielded probe with 2π source geometry, whereas logging sonde with instruments through the steel armoured cable are employed for point to 4π geometry. Spectral borehole logging system with built-in multi-channel analyser (MCA) has been developed for the uranium exploration programme for AMD. Note-book PC based high sensitivity air-borne gamma-ray spectrometric survey system has been designed, developed and test flown. (author)

  6. Using an Instrumented Drone to Sample Dust Devils

    Science.gov (United States)

    Jackson, Brian; Lorenz, Ralph; Davis, Karan; Lipple, Brock

    2017-10-01

    Dust devils are low-pressure, small (many to tens of meters) convective vortices powered by surface heating and rendered visible by lofted dust. Dust devils occur in arid climates on Earth, where they degrade air quality and pose a hazard to small aircraft. They also occur ubiquitously on Mars, where they may dominate the supply of atmospheric dust. Since dust contributes significantly to Mars’ atmospheric heat budget, dust devils probably play an important role in its climate. The dust-lifting capacity of a devil likely depends sensitively on its structure, particularly the wind and pressure profiles, but the exact dependencies are poorly constrained. Thus, the exact contribution to Mars’ atmosphere remains unresolved. Moreover, most previous studies of martian dust devils have relied on passive sampling of the profiles via meteorology packages on landed spacecraft, resulting in random encounter geometries which non-trivially skew the retrieved profiles. Analog studies of terrestrial devils have employed more active sampling (instrumented vehicles or manned aircraft) but have been limited to near-surface (few meters) or relatively high altitude (hundreds of meters) sampling. Unmanned aerial vehicles (UAVs) or drones, combined with miniature, digital instrumentation, promise a novel and uniquely powerful platform from which to sample dust devils via (relatively) controlled geometries at a wide variety of altitudes. In this presentation, we will describe a pilot study using an instrumented quadcopter on an active field site in southeastern Oregon, which (to our knowledge) has not previously been surveyed for dust devils. We will present preliminary results from the resulting encounters, including stereo image analysis and encounter footage collected onboard the drone.

  7. The Prospects of Musical Instruments For People with Physical Disabilities

    DEFF Research Database (Denmark)

    Larsen, Jeppe Veirum; Overholt, Daniel; Moeslund, Thomas B.

    2016-01-01

    Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions thro...... instruments, music-supported therapy, and recent trends in the area. The overview is extrapolated to look at where the research is headed, providing insights for potential future work.......Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions...... through therapeutic use. The field of musical instruments for people with physical disabilities, however, is still an emerging area of research. In this article, we look at the current state of developments, including a survey of custom designed instruments, augmentations / modifications of existing...

  8. The STAFF-DWP wave instrument on the DSP equatorial spacecraft: description and first results

    Directory of Open Access Journals (Sweden)

    N. Cornilleau-Wehrlin

    2005-11-01

    Full Text Available The STAFF-DWP wave instrument on board the equatorial spacecraft (TC1 of the Double Star Project consists of a combination of 2 instruments which are a heritage of the Cluster mission: the Spatio-Temporal Analysis of Field Fluctuations (STAFF experiment and the Digital Wave-Processing experiment (DWP. On DSP-TC1 STAFF consists of a three-axis search coil magnetometer, used to measure magnetic fluctuations at frequencies up to 4 kHz and a waveform unit, up to 10 Hz, plus snapshots up to 180 Hz. DWP provides several onboard analysis tools: a complex FFT to fully characterise electromagnetic waves in the frequency range 10 Hz-4 kHz, a particle correlator linked to the PEACE electron experiment, and compression of the STAFF waveform data. The complementary Cluster and TC1 orbits, together with the similarity of the instruments, permits new multi-point studies. The first results show the capabilities of the experiment, with examples in the different regions of the magnetosphere-solar wind system that have been encountered by DSP-TC1 at the beginning of its operational phase. An overview of the different kinds of electromagnetic waves observed on the dayside from perigee to apogee is given, including the different whistler mode waves (hiss, chorus, lion roars and broad-band ULF emissions. The polarisation and propagation characteristics of intense waves in the vicinity of a bow shock crossing are analysed using the dedicated PRASSADCO tool, giving results compatible with previous studies: the broad-band ULF waves consist of a superimposition of different wave modes, whereas the magnetosheath lion roars are right-handed and propagate close to the magnetic field. An example of a combined Cluster DSP-TC1 magnetopause crossing is given. This first case study shows that the ULF wave power intensity is higher at low latitude (DSP than at high latitude (Cluster. On the nightside in the tail, a first wave event comparison - in a rather quiet time interval

  9. An instrument to measure passenger satisfaction of a public transport system

    Directory of Open Access Journals (Sweden)

    Viviane Leite Dias de Mattos

    2017-03-01

    Full Text Available This study proposes an instrument, based on fuzzy logic, to measure the satisfaction with the public transport. It is based on previous studies, expert opinion and results of two surveys conducted among the data samples of the studied population: a university community. Qualitative techniques (questionaries and interviews were used for validating content, while the construct validation uses quantitative techniques (Factor Analysis and Reliability Analysis. An experiment is also performed to define some properties of fuzzy controllers: membership function and method of defuzzification. The final instrument consists of twenty items in four dimensions, namely: service, stops/terminals, vehicle and safety. It is considered valid and reliable by the present study. It can be used as a tool to understand the satisfaction of the passengers of public transport system investigated. It can also provide subsidies for managers to improve their work quality.

  10. The Southern HII Region Discovery Survey: Preliminary Results

    Science.gov (United States)

    Shea, Jeanine; Wenger, Trey; Balser, Dana S.; Anderson, Loren D.; Armentrout, William P.; Bania, Thomas M.; Dawson, Joanne; Miller Dickey, John; Jordan, Christopher; McClure-Griffiths, Naomi M.

    2017-01-01

    HII regions are some of the brightest sources at radio frequencies in the Milky Way and are the sites of massive O and B-type star formation. They have relatively short (Bank Telescope. Candidate HII regions were selected from mid-infrared emission coincident with radio continuum emission, and confirmed as HII regions by the detection of radio recombination lines. Here we discuss the Southern HII Region Discovery Survey (SHRDS), a continuation of the HRDS using the Australia Telescope Compact Array over the Galactic longitude range 230 to 360 degrees. We have reduced and analyzed a small sub-set of the SHRDS sources and discuss preliminary results, including kinematic distances and metallicities.

  11. Determinants of persistence in hypertensive patients treated with irbesartan: results of a postmarketing survey

    Directory of Open Access Journals (Sweden)

    Greminger Peter

    2005-06-01

    Full Text Available Abstract Background Persistence is a key factor for long-term blood pressure control, which is of high prognostic importance for patients at increased cardiovascular risk. Here we present the results of a post-marketing survey including 4769 hypertensive patients treated with irbesartan in 886 general practices in Switzerland. The goal of this survey was to evaluate the tolerance and the blood pressure lowering effect of irbesartan as well as the factors affecting persistence in a large unselected population. Methods Prospective observational survey conducted in general practices in all regions of Switzerland. Previously untreated and uncontrolled pre-treated patients were started with a daily dose of 150 mg irbesartan and followed up to 6 months. Results After an observation time slightly exceeding 4 months, the average reduction in systolic and diastolic blood pressure was 20 (95% confidence interval (CI -19.6 to -20.7 mmHg and 12 mmHg (95% CI -11.4 to -12.1 mmHg, respectively. At this time, 26% of patients had a blood pressure Conclusion The results of this survey confirm that irbesartan is effective, well tolerated and well accepted by patients, as indicated by the good persistence. This post-marketing survey also emphasizes the importance of the tolerability profile and of achieving an early control of blood pressure as positive predictors of persistence.

  12. Designing an Instrument to Measure the QoS of a Spanish Virtual Store

    Science.gov (United States)

    de Abajo, Beatriz Sainz; de La Torre Díez, Isabel; Salcines, Enrique García; Fernández, Javier Burón; Pernas, Francisco Díaz; Coronado, Miguel López; de Castro Lozano, Carlos

    This article describes the development of an instrument, in the form of a survey, which is distributed to users of a B2C website selling electronic books in order to ascertain their satisfaction. The opinions compiled from a pilot sample and the exploratory factor analysis carried out point to factors that best summarise the quality of the application analysed here. Analysis of the initial survey, with a total of 40 items, shaped the final instrument, encompassing 18 items divided into 6 dimensions, which measure the perceptions of users of the application in order to improve the contents of the website. Subsequently, a confirmatory factorial analysis is performed, ensuring the reliability of the study and which confirms that the structure of the instrument developed truly measures service quality in accordance with the requirements of the website in terms of offering a space that fulfils consumer expectations in the Information Society.

  13. Gamma radiometric survey of Jamaica

    International Nuclear Information System (INIS)

    Lalor, G.C.; Robotham, H.; Miller, J.M.; Simpson, P.R.

    1989-01-01

    The results of a total gamma radiometric survey of Jamaica, carried out with car-borne instrumentation, are presented and the data compared with the contents of potassium, thorium and uranium in rocks and in surface (soil, stream-sediment, pan concentrate and water) samples obtained at six sites selected to be representative of the principal rock types and surface environments of Jamaica. The work formed part of an orientation study for a regional geochemical survey of the CARICOM countries of the Caribbean. The initial results indicate that enhanced gamma activity is correlated with enrichment in uranium and thorium, but not potassium, in terra rossa soils and/or bauxite deposits in limestone. Elsewhere, gamma levels are increased on the Above Rocks Cretaceous basement Inlier, where they correlate generally with the presence of volcanogenic sediments and a granodiorite intrusion. The lowest radioactivity was recorded in the vicinity of ultrabasic rocks in the Blue Mountains Inlier. (author)

  14. The analysis of the survey results for the current 'business agent'

    International Nuclear Information System (INIS)

    Kim, I. H.; Shim, H. S.; Jeon, I. Y.; Kang, W. S.; Yun, K. H.; Na, S. H.; Park, T. J.; Kim, I. S.

    2004-01-01

    Our survey is conducted about the current systems in the 'Business Agents' regulations which prescribes running business such as the safe control of radiation on behalf of any permitted users. The radiation safety staffs who are engaged in the handling of radioisotope respond our quaternaries. They are as follows: 1. the radiation safety staffs' attitude to the need of 'Business Agent' regulations, 2. the satisfaction level of 'Business Agent' service, 3. the propriety of the manpower. The survey results are that the 68.4% of the respondents are in favor of the need of 'Business Agent' regulations and the 63.6% of the respondents expressed satisfactions for the service of 'Business Agent'. For the one manpower managing 'Business Agent', 32.3% of the respondents expressed as 'overburdened' and 37.5% as 'appropriate.' Our results give the feedback to develop the system of 'Business Agent' regulations as making feedback effect

  15. Development and use of an instrument to measure scientific inquiry and related factors

    Science.gov (United States)

    Dunbar, Terry Frank

    The use of the scientific inquiry method of teaching science was investigated in one district's elementary schools. The study generated data directly from Albuquerque Public Schools fourth- and fifth-grade teachers through a mail-out survey and through observation. Two forms of an inquiry evaluation research instrument (Elementary Science Inquiry Survey - ESIS) were created. The ESIS-A is a classroom observation tool. The ESIS-B is a survey questionnaire designed to collect information from teachers. The study was designed first to establish reliability and validity for both forms of the instrument. The study made use of multiple regression and exploratory factor analysis. Sources used to establish the instruments' reliability and validity included: (1) Input from an international panel (qualitative analysis of comments sent by raters and quantitative analysis of numerical ratings sent by raters); (2) Cronbach's alpha; (3) Results of factor analysis; (4) Survey respondents' comments (qualitative analysis); (5) Teacher observation data. Cronbach's alpha for the data set was .8955. Inquiry practices were reported to occur between twice per week and three times per week. Teachers' comments regarding inquiry were reported. The ESIS was used to collect inquiry self-report data and teacher background data. The teacher background data included teacher science knowledge and information about their standards awareness and implementation. The following teacher knowledge factors were positively correlated with inquiry use: semesters of college science, science workshops taken, conducted scientific research, and SIMSE (NSF institute) participation. The following standards awareness and implementation factors were positively correlated with inquiry use: familiarity with the National Science Education Standards, familiarity with New Mexico science standards, state or national standards as a curriculum selection factor, student interest as a curriculum selection factor, and "no

  16. Engineering surveying theory and examination problems for students

    CERN Document Server

    Schofield, W

    2013-01-01

    Engineering Surveying: Theory and Examination Problems for Students, Volume 1, Third Edition discusses topics concerning engineering surveying techniques and instrumentations. The book is comprised of eight chapters that cover several concerns in engineering survey. Chapter 1 discusses the basic concepts of surveying. Chapter 2 deals with simple and precise leveling, while Chapter 3 covers earthworks. The book also talks about the theodolite and its applications, and then discusses optical distance measurement. Curves, underground and hydrographic surveying, and aspects of dimensional control

  17. The creation and validation of an instrument to measure school STEM Culture

    Science.gov (United States)

    White, Christopher

    Although current research exists on school culture, there is a gap in the literature on specialized aspects of culture such as STEM Culture defined as the beliefs, values, practices, resources, and challenges in STEM fields (Science, Technology, Engineering and Mathematics) within a school. The objective of this study was to create a valid and reliable instrument, the STEM Culture Assessment Tool (STEM-CAT), that measures this cultural aspect based on a survey of stakeholder groups within the school community and use empirical data to support the use of this instrument to measure STEM Culture. Items were created and face validity was determined through a focus group and expert review before a pilot study was conducted to determine reliability of the items. Once items were determined reliable, the survey was given to eight high schools and results were correlated to the percentage of seniors who self-reported whether they intend to pursue STEM fields upon graduation. The results of this study indicate further need for research to determine how the STEM-CAT correlates to STEM culture due to some inconsistencies with the dependent variable in this study. Future research could be done correlating the results of the STEM-CAT with participation in Advanced Placement science and mathematics, SAT/ACT scores in science and mathematics or the number of students who actually pursue STEM fields rather than a prediction halfway through the 12th grade.

  18. The ART-XC Instrument on Board the SRG Mission

    Science.gov (United States)

    Pavlinksy, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovish, A.; hide

    2012-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in 2014 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes . a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules with seven corresponding cadmium-telluride focal plane detectors. Each will operate over the approximate energy range of 6- 30 keV, with an angular resolution of <1 ', a field of view of 30 ' and an energy resolution about 10% at 14 keV. The NASA Marshall Space Flight Center (MSFC) will fabricate some of the mirror modules, to complement others fabricated by VNIIEF in Russia.

  19. PEP surveying procedures and equipment

    International Nuclear Information System (INIS)

    Linker, F.

    1982-06-01

    The PEP Survey and Alignment System, which employs both laser-based and optical survey methods, is described. The laser is operated in conjunction with the Tektronix 4051 computer and surveying instruments such as ARM and SAM, system which is designed to automate data input, reduction, and production of alignment instructions. The laser system is used when surveying ring quadrupoles, main bend magnets, sextupoles, and is optional when surveying RF cavities and insertion quadrupoles. Optical methods usually require that data be manually entered into the computer for alignment, but in some cases, an element can be aligned using nominal values of fiducial locations without use of the computer. Optical surveying is used in the alignment of NIT and SIT, low field bend magnets, wigglers, RF cavities, and insertion quadrupoles

  20. The interface between child/adolescent and adult mental health services: results from a European 28-country survey.

    Science.gov (United States)

    Signorini, Giulia; Singh, Swaran P; Marsanic, Vlatka Boricevic; Dieleman, Gwen; Dodig-Ćurković, Katarina; Franic, Tomislav; Gerritsen, Suzanne E; Griffin, James; Maras, Athanasios; McNicholas, Fiona; O'Hara, Lesley; Purper-Ouakil, Diane; Paul, Moli; Russet, Frederick; Santosh, Paramala; Schulze, Ulrike; Street, Cathy; Tremmery, Sabine; Tuomainen, Helena; Verhulst, Frank; Warwick, Jane; de Girolamo, Giovanni

    2018-04-01

    Transition-related discontinuity of care is a major socioeconomic and societal challenge for the EU. The current service configuration, with distinct Child and Adolescent Mental Health (CAMHS) and Adult Mental Health Services (AMHS), is considered a weak link where the care pathway needs to be most robust. Our aim was to delineate transitional policies and care across Europe and to highlight current gaps in care provision at the service interface. An online mapping survey was conducted across all 28 European Countries using a bespoke instrument: The Standardized Assessment Tool for Mental Health Transition (SATMEHT). The survey was directed at expert(s) in each of the 28 EU countries. The response rate was 100%. Country experts commonly (12/28) reported that between 25 and 49% of CAMHS service users will need transitioning to AMHS. Estimates of the percentage of AMHS users aged under 30 years who had has previous contact with CAMHS were most commonly in the region 20-30% (33% on average).Written policies for managing the interface were available in only four countries and half (14/28) indicated that no transition support services were available. This is the first survey of CAMHS transitional policies and care carried out at a European level. Policymaking on transitional care clearly needs special attention and further elaboration. The Milestone Study on transition should provide much needed data on transition processes and outcomes that could form the basis for improving policy and practice in transitional care.

  1. Validation of the Care-Related Quality of Life Instrument in different study settings: findings from The Older Persons and Informal Caregivers Survey Minimum DataSet (TOPICS-MDS).

    Science.gov (United States)

    Lutomski, J E; van Exel, N J A; Kempen, G I J M; Moll van Charante, E P; den Elzen, W P J; Jansen, A P D; Krabbe, P F M; Steunenberg, B; Steyerberg, E W; Olde Rikkert, M G M; Melis, R J F

    2015-05-01

    Validity is a contextual aspect of a scale which may differ across sample populations and study protocols. The objective of our study was to validate the Care-Related Quality of Life Instrument (CarerQol) across two different study design features, sampling framework (general population vs. different care settings) and survey mode (interview vs. written questionnaire). Data were extracted from The Older Persons and Informal Caregivers Minimum DataSet (TOPICS-MDS, www.topics-mds.eu ), a pooled public-access data set with information on >3,000 informal caregivers throughout the Netherlands. Meta-correlations and linear mixed models between the CarerQol's seven dimensions (CarerQol-7D) and caregiver's level of happiness (CarerQol-VAS) and self-rated burden (SRB) were performed. The CarerQol-7D dimensions were correlated to the CarerQol-VAS and SRB in the pooled data set and the subgroups. The strength of correlations between CarerQol-7D dimensions and SRB was weaker among caregivers who were interviewed versus those who completed a written questionnaire. The directionality of associations between the CarerQol-VAS, SRB and the CarerQol-7D dimensions in the multivariate model supported the construct validity of the CarerQol in the pooled population. Significant interaction terms were observed in several dimensions of the CarerQol-7D across sampling frame and survey mode, suggesting meaningful differences in reporting levels. Although good scientific practice emphasises the importance of re-evaluating instrument properties in individual research studies, our findings support the validity and applicability of the CarerQol instrument in a variety of settings. Due to minor differential reporting, pooling CarerQol data collected using mixed administration modes should be interpreted with caution; for TOPICS-MDS, meta-analytic techniques may be warranted.

  2. The knowledge, efficacy, and practices instrument for oral health providers: a validity study with dental students.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cyndi W; Moore, Thomas E; Catalanotto, Frank A

    2013-08-01

    Valid and reliable instruments to measure and assess cultural competence for oral health care providers are scarce in the literature, and most published scales have been contested due to a lack of item analysis and internal estimates of reliability. The purposes of this study were, first, to develop a standardized instrument to measure dental students' knowledge of diversity, skills in culturally competent patient-centered communication, and use of culture-centered practices in patient care and, second, to provide preliminary validity support for this instrument. The initial instrument used in this study was a thirty-six-item Likert-scale survey entitled the Knowledge, Efficacy, and Practices Instrument for Oral Health Providers (KEPI-OHP). This instrument is an adaption of an initially thirty-three-item version of the Multicultural Awareness, Knowledge, and Skills Scale-Counselor Edition (MAKSS-CE), a scale that assesses factors related to social justice, cultural differences among clients, and cross-cultural client management. After the authors conducted cognitive and expert interviews, focus groups, pilot testing, and item analysis, their initial instrument was reduced to twenty-eight items. The KEPI-OHP was then distributed to 916 dental students (response rate=48.6 percent) across the United States to measure its reliability and assess its validity. Both exploratory and confirmatory factor analyses were conducted to test the scale's validity. The modification of the survey into a sensible instrument with a relatively clear factor structure using factor analysis resulted in twenty items. A scree test suggested three expressive factors, which were retained for rotation. Bentler's comparative fit and Bentler and Bonnett's non-normed indices were 0.95 and 0.92, respectively. A three-factor solution, including efficacy of assessment, knowledge of diversity, and culture-centered practice subscales, comprised of twenty-items was identified. The KEPI-OHP was found to

  3. Tesla VUPJT instruments for radiation monitoring of working environment and selected aplications

    International Nuclear Information System (INIS)

    Slezak, V.; Kula, J.; Novakova, O.; Jursova, L.; Severa, L.

    1986-01-01

    A survey is presented of the current state of development and production of instruments for ionizing radiation monitoring and detection, also listing possible applications in the national economy. (author)

  4. LAMOST spectral survey — An overview

    International Nuclear Information System (INIS)

    Zhao Gang; Zhao Yongheng; Chu Yaoquan; Deng Licai; Jing Yipeng

    2012-01-01

    LAMOST (Large sky Area Multi-Object fiber Spectroscopic Telescope) is a Chinese national scientific research facility operated by National Astronomical Observatories, Chinese Academy of Sciences (NAOC). After two years of commissioning beginning in 2009, the telescope, instruments, software systems and operations are nearly ready to begin the main science survey. Through a spectral survey of millions of objects in much of the northern sky, LAMOST will enable research in a number of contemporary cutting edge topics in astrophysics, such as discovery of the first generation stars in the Galaxy, pinning down the formation and evolution history of galaxies — especially the Milky Way and its central massive black hole, and looking for signatures of the distribution of dark matter and possible sub-structures in the Milky Way halo. To maximize the scientific potential of the facility, wide national participation and international collaboration have been emphasized. The survey has two major components: the LAMOST ExtraGAlactic Survey (LEGAS) and the LAMOST Experiment for Galactic Understanding and Exploration (LEGUE). Until LAMOST reaches its full capability, the LEGUE portion of the survey will use the available observing time, starting in 2012. An overview of the LAMOST project and the survey that will be carried out in the next five to six years is presented in this paper. The science plan for the whole LEGUE survey, instrumental specifications, site conditions, and the descriptions of the current on-going pilot survey, including its footprints and target selection algorithm, will be presented as separate papers in this volume.

  5. Development and pilot of an international survey: 'Radiation Therapists and Psychosocial Support'.

    Science.gov (United States)

    Elsner, Kelly L; Naehrig, Diana; Halkett, Georgia K B; Dhillon, Haryana M

    2018-06-07

    Up to one third of radiation therapy patients are reported to have unmet psychosocial needs. Radiation therapists (RTs) have daily contact with patients and can provide daily psychosocial support to reduce patient anxiety, fear and loneliness. However, RTs vary in their values, skills, training, knowledge and involvement in providing psychosocial support. The aims of this study were to: (1) develop an online survey instrument to explore RT values, skills, training and knowledge regarding patient anxiety and psychosocial support, and (2) pilot the instrument with RT professionals to assess content validity, functionality and length. An online cross-sectional survey, titled 'Radiation therapists and psychosocial support' was developed. Items included patient vignettes, embedded items from RT research, and the Professional Quality of Life Scale (ProQOL5). Four radiation oncology departments volunteered to pilot the survey; each nominated four RT staff to participate. Survey data were analysed descriptively and qualitative feedback grouped and coded to determine whether the survey needed to be refined. Thirteen of sixteen RTs completed the pilot survey and feedback form. Median time to completion was 35 mins, with 54% of respondents stating this was too long. Respondents reported content, questions and response options were relevant and appropriate. Feedback was used to: refine the survey instrument, minimise responder burden and drop out and improve functionality and quality of data collection. This pilot of the 'Radiation therapists and psychosocial support' survey instrument demonstrated content validity and usability. The main survey will be circulated to a representative sample of RTs for completion. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  6. The amazing vanishing Canadian dermatologist: results from the 2006 Canadian Dermatology Association member survey.

    Science.gov (United States)

    Chow, Eunice Y; Searles, Gordon E

    2010-01-01

    The 2006 Canadian Dermatology Association (CDA) member survey tracked the Canadian dermatology workforce. Information on use of nondermatologist extenders, impact of financial burden on practice style, and wait times was collected in the survey. To survey Canadian dermatologists for specialty-specific physician resource information including demographics, workload, and future career plans and compare it to results from the 2001 survey. In addition, to explore three other areas not covered in the previous survey: patient access to dermatologic care through wait times, the use of nondermatologist extenders, and potential impact of educational financial debt on practice styles. CDA members in 2006 were surveyed by mail. Follow-up mailings were done for nonresponders. Survey results were compared to those of the 2001 survey. Thirty-six percent (216 of 602) of Canadian dermatologists responded (70% in 2001). The national distribution was identical between surveys. The median age increased to 55 years; two-thirds of dermatologists are male. The median retirement age remained at 65 years. There was a shift from rural to urban practice locations; 78% practice in private offices. Three-fifths of dermatologists do mainly medical dermatology, a decrease between surveys. Pediatric dermatology decreased 10%, whereas surgical dermatology increased 52% between surveys. Fewer practitioners perform noninsured services, and half as many perform research or hospital consultations or teach medical students. Financial debt burden had no impact on selection of practice style. Median wait times for nonurgent consultations doubled from 5 to 10 weeks; follow-up visits increased from 4 to 5 weeks; noninsured consultations increased from 4 to 5 weeks. The national median wait time for a third available consultation appointment was 42 days (range 7-161 days). Seventeen percent of dermatologists reported using nondermatologist extenders. Training programs produce only 60% of new practitioners

  7. HEAO A-2 extragalactic results

    Science.gov (United States)

    Boldt, E. A.

    1979-01-01

    The all-sky surveys made with the A-2 instrument aboard HEAO-1 involved spectroscopy over a broad enough band width, with sufficient resolution, to obtain the basic spectral characteristics for two extreme aspects of the extragalactic X-ray sky. The overall spectrum (above 3 KeV) is remarkably well decribed by a thermal model. At the other extreme, the detailed broad-band observations of individual sources are restricted to objects within the present epoch. The objects include several individual active galaxies studied in detail for the first time as well as clusters of galaxies. Relating these results to the vast spatially unresolved hard X-ray flux measured with this instruments as well as the softer X-rays (at less than 3 keV) spatially resolved to high redshifts with the Einstein Observatory remains a challenge.

  8. Client Perceptions of Occupational Health and Safety Management System Assistance Provided by OSHA On-Site Consultation: Results of a Survey of Colorado Small Business Consultation Clients.

    Science.gov (United States)

    Autenrieth, Daniel A; Brazile, William J; Gilkey, David P; Reynolds, Stephen J; June, Cathy; Sandfort, Del

    2015-01-01

    The Occupational Safety and Health Administration (OSHA) On-Site Consultation Service provides assistance establishing occupational health and safety management systems (OHSMS) to small businesses. The Safety and Health Program Assessment Worksheet (Revised OSHA Form 33) is the instrument used by consultants to assess an organization's OHSMS and provide feedback on how to improve a system. A survey was developed to determine the usefulness of the Revised OSHA Form 33 from the perspective of Colorado OSHA consultation clients. One hundred and seven clients who had received consultation services within a six-year period responded to the survey. The vast majority of respondents indicated that the Revised OSHA Form 33 accurately reflected their OHSMS and that information provided on the Revised OSHA Form 33 was helpful for improving their systems. Specific outcomes reported by the respondents included increased safety awareness, reduced injuries, and improved morale. The results indicate that the OHSMS assistance provided by OSHA consultation is beneficial for clients and that the Revised OSHA Form 33 can be an effective tool for assessing and communicating OHSMS results to business management. Detailed comments and suggestions provided on the Revised OSHA Form 33 are helpful for clients to improve their OHSMS.

  9. Planck early results. V. The Low Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Poutanen, T.; Lähteenmäki, A.; León-Tavares, J.

    2011-01-01

    We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discuss the steps involved in reducing the data from telemetry packets to cleaned, calibrated, time-ordered data (TOD) and ...... statistical uncertainties on LFI and Planck products are also produced. Main beams are estimated down to the ≈ -10dB level using Jupiter transits, which are also used for geometrical calibration of the focal plane. © ESO, 2011....

  10. The role of instrumental, hedonic and symbolic attributes in the intention to adopt electric vehicles

    DEFF Research Database (Denmark)

    Schuitema, Geertje; Anable, Jillian; Skippon, Stephen

    2013-01-01

    The aim is to understand how private car drivers’ perception of vehicle attributes may affect their intention to adopt electric vehicles (EVs). Data are obtained from a national online survey of potential EV adopters in the UK. The results indicate that instrumental attributes are important largely...... to have positive perceptions of EV attributes. Perceptions of EV attributes are only very weakly associated with car-authority identity....

  11. FY 1999 report on the results of the research and development project for the photon-aided instrumentation and processing technologies. R and D of the photon-aided instrumentation and processing technologies; 1999 nendo photon keisoku kako gijutsu seika hokokusho. Photon keisoku kako gijutsu no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 1999 results of development of the photon-aided instrumentation and processing technologies. The photon technologies will be widely applicable to various industrial areas, e.g., medical, diagnostic, communication, transmission and chemical areas, in addition to instrumentation and processing, and the FY 1999 project is directed to the survey and analysis of the information, and prediction of their effects. The high-sensitivity light-receiving elements enlarged up to 5mm diameter (effective area) are developed, based on the technologies to grow the thin films using an MOVPE (metal-organic vapor-phase epitaxy) device and the results of development of the infrared ray-receiving InGaAs photodiode sensitive in a 2.5 to 2.7{mu}m wavelength range. The surface roughness of 0.4nmRMS is achieved by the bowl feed liquid polishing method, to develop the processing technologies for high-precision substrates for optical mirrors. The results are used to develop the prototype X-ray mirrors with surface accuracy of {lambda}/10 to {lambda}/20 and roughness of 0.3 to 0.5nmRMS. In the development of the technologies for the light sources which can sufficiently supply photons for exciting semiconductor lasers, the technologies are developed to efficiently converge the laser beams. Also developed are the apparatus which can converge the beams to a diameter of around 0.6mm, and the apparatus which uses optical fibers to evaluate the beam diameter. (NEDO)

  12. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    Science.gov (United States)

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  13. The S201 far-ultraviolet imaging survey - A summary of results and implications for future surveys

    Science.gov (United States)

    Carruthers, G. R.; Page, T.

    1984-01-01

    The results from all-sky surveys with the S201 FUV camera/spectrograph from the moon during the Apollo 16 mission are summarized with respect to implications for future UV all-sky surveys. The scans provided imagery of 10 fields, each 20 deg in diameter, in the wavelength ranges 1050-1600 A and 1250-1600 A. Best detection thresholds were obtained with 10 and 30 min exposures at 1400 A. Only 7 percent sky coverage was recorded, and then only down to 11th mag. A Mark II camera may be flown on the Shuttle on the Spartan 3 mission, as may be an all-reflector Schmidt telescope. An additional 20 percent of the sky will be mapped and microchannel intensification will increase the diffuse source sensitivity by two orders of magnitude. Several objects sighted with the S201 will be reviewed with the Mark II.

  14. Feedback to Managers, Volume II: A Review and Comparison of Sixteen Multi-Rater Feedback Instruments.

    Science.gov (United States)

    Van Velsor, Ellen; Leslie, Jean Brittain

    "Feedback to Managers" is a two-volume report. Volume 2 compares 16 of the better feedback instruments available. The following are the instruments: (1) ACUMEN Group Feedback; (2) BENCHMARKS; (3) the Campbell Leadership Index; (4) COMPASS: the Managerial Practices Survey; (5) the Executive Success Profile; (6) Leader Behavior Analysis…

  15. The Belgian Risk Perception Barometer Risk Perception Measuring Instruments Revisited

    International Nuclear Information System (INIS)

    Aeken, Koen van; Carle, Benny; Hardeman, Frank

    2006-01-01

    The recognition of the societal dimension of risk assessment has been at the cradle of the opinion research on risks. Since risk estimates are not fixed by experts anymore, but are considered to show variation across a diverse population, the people themselves must be asked how they experience the risks. Following the rise in popularity of risk assessment and the recognition of its 'human' dimension, the demand for public opinion surveys on risks has been increasing at a fast pace. Unfortunately, this high demand sees some negative consequences. First, surveys are frequently conducted by people lacking even a minimal knowledge of survey methodology. In this respect, we might think of a journal or a newspaper trying to impress their readers with the definitive public opinion poll about the latest issue in vogue. Second, time pressure causes experienced or trained researchers to lower themselves to 'quick and dirty' work. While methodologically flawed opinion research might not be something to worry about when appearing in the amusement press, concern is due if the results of a survey inspire policy development. Indeed, when public opinion research is conceived as an instrument to support rational, evidence based public policy, the strictest methodological standards should be applied, even if it is clear that scientific research will never substitute political reasoning. This contribution deals with the safeguarding and enhancing of the quality of large scale surveys focusing on risk perception and related issues. This attention is relevant, not only for the reason that methodological standards may be flawed due to the immense popularity of the opinion poll, but also because the results of opinion surveys may have far-reaching policy consequences

  16. The Belgian Risk Perception Barometer Risk Perception Measuring Instruments Revisited

    Energy Technology Data Exchange (ETDEWEB)

    Aeken, Koen van; Carle, Benny; Hardeman, Frank [SCK-CEN, Mol (Belgium). PISA

    2006-09-15

    The recognition of the societal dimension of risk assessment has been at the cradle of the opinion research on risks. Since risk estimates are not fixed by experts anymore, but are considered to show variation across a diverse population, the people themselves must be asked how they experience the risks. Following the rise in popularity of risk assessment and the recognition of its 'human' dimension, the demand for public opinion surveys on risks has been increasing at a fast pace. Unfortunately, this high demand sees some negative consequences. First, surveys are frequently conducted by people lacking even a minimal knowledge of survey methodology. In this respect, we might think of a journal or a newspaper trying to impress their readers with the definitive public opinion poll about the latest issue in vogue. Second, time pressure causes experienced or trained researchers to lower themselves to 'quick and dirty' work. While methodologically flawed opinion research might not be something to worry about when appearing in the amusement press, concern is due if the results of a survey inspire policy development. Indeed, when public opinion research is conceived as an instrument to support rational, evidence based public policy, the strictest methodological standards should be applied, even if it is clear that scientific research will never substitute political reasoning. This contribution deals with the safeguarding and enhancing of the quality of large scale surveys focusing on risk perception and related issues. This attention is relevant, not only for the reason that methodological standards may be flawed due to the immense popularity of the opinion poll, but also because the results of opinion surveys may have far-reaching policy consequences.

  17. Beverages consumption in Brazil: results from the first National Dietary Survey

    Science.gov (United States)

    Pereira, Rosangela A; Souza, Amanda M; Duffey, Kiyah J; Sichieri, Rosely; Popkin, Barry M

    2014-01-01

    Objective To provide an overview of beverage consumption patterns using the first nationally representative survey of dietary intake in Brazil. Design Beverage consumption data were obtained by 1-day food records in an individual dietary survey. Setting nationwide cross-sectional survey, 2008–09. Subjects nationally representative sample of individuals ≥10 years (n=34,003). Results Beverages contributed to 17.1% of total energy consumption. Caloric coffee beverages provided the greatest level of energy overall (464 kJ or 111 kcal/d). Individuals from 10 to 18 (243 kJ or 58 kcal/d) and from 19 to 39 years old (230 kJ or 55 kcal/d consumed higher proportion of energy from sugar sweetened soft drinks than individuals over this age (142 kJ or 34 kcal/d for those 40–59 and 79 kJ or 19 kcal/d for those >60 years old). Conclusions Overall, the contribution of beverages, particularly sugary beverages, to total energy consumption in Brazil represents an important public health challenge and is comparable with those from other countries. PMID:25158687

  18. THE FREQUENCY OF HOT JUPITERS IN THE GALAXY: RESULTS FROM THE SuperLupus SURVEY

    International Nuclear Information System (INIS)

    Bayliss, Daniel D. R.; Sackett, Penny D.

    2011-01-01

    We present the results of the SuperLupus Survey for transiting hot Jupiter planets, which monitored a single Galactic disk field spanning 0.66 deg 2 for 108 nights over three years. Ten candidates were detected: one is a transiting planet, two remain candidates, and seven have been subsequently identified as false positives. We construct a new image quality metric, S j , based on the behavior of 26,859 light curves, which allows us to discard poor images in an objective and quantitative manner. Furthermore, in some cases we are able to identify statistical false positives by analyzing temporal correlations between S j and transit signatures. We use Monte Carlo simulations to measure our detection efficiency by injecting artificial transits onto real light curves and applying identical selection criteria as used in our survey. We find at 90% confidence level that 0.10 +0.27 –0.08 % of dwarf stars host a hot Jupiter with a period of 1-10 days. Our results are consistent with other transit surveys, but appear consistently lower than the hot Jupiter frequencies reported from radial velocity surveys, a difference we attribute, at least in part, to the difference in stellar populations probed. In light of our determination of the frequency of hot Jupiters in Galactic field stars, previous null results for transiting planets in open cluster and globular cluster surveys no longer appear anomalously low.

  19. The DAFT/FADA Survey status and latest results

    Science.gov (United States)

    Guennou, L.

    2011-12-01

    We present here the latest results obtained from the American French collaboration called the Dark energy American French Team/French American DArk energy Team (DAFT/FADA). The goal of the DAFT/FADA collaboration is to carry out a weak lensing tomography survey of z = 0.4-0.9 rich clusters of galaxies. Unlike supernovae or other methods such as cluster of galaxy counts, weak lensing tomography is purely based on geometry and does not depend on knowledge of the physics of the objects used as distance indicators. In addition, the reason for analyzing observations in the direction of clusters is that the shear signal is enhanced by about 10 over the field. Our work will eventually contain results obtained on 91 rich clusters from the HST archive combined with ground based work to obtain photo-zs. This combination of photo-z and weak lensing tomography will enable us to constrain the equation of state of dark energy. We present here the latest results obtained so far in this study.

  20. Development of measurement apparatus for high resolution electrical surveys; Komitsudo denki tansa sokuteiki no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Moriuchi, H; Matsuda, Y; Shiokawa, Y [Sumiko Consultants Co. Ltd., Tokyo (Japan); Uchino, Y [Cosmic Co. Ltd., Tokyo (Japan)

    1996-05-01

    For the enforcement of the {rho}a-{rho}u survey method which is a type of high-density electrical survey, a multichannel resistivity measuring instrument has been developed. This instrument, in addition to the above, conducts resistivity tomography and various other kinds of high-density electrical survey. A potential produced by a low frequency rectangular current of 1Hz or lower outputted by the transmitter of this instrument is received and measured by the receiver connected to electrodes positioned at 100 or less locations. The receiver comprises a scanner that automatically switches from electrode to electrode, conditioner that processes signals, and controller. A transmitter of the standard design outputs a maximum voltage of 800V and maximum current of 2A, making a device suitable for probing 50 to several 100m-deep levels. The receiver is operated by a personal computer that the controller is provided with. The newly-developed apparatus succeeded in presenting high-precision images of the result of a {rho}a-{rho}u analysis for an apparent resistivity section and of the underground structure, verifying the high quality of the data collected by this apparatus. 10 refs., 5 figs., 1 tab.

  1. Current and Developing Conceptions of Use: Evaluation Use TIG Survey Results.

    Science.gov (United States)

    Preskill, Hallie; Caracelli, Valerie

    1997-01-01

    A survey was sent to members of the Evaluation Use Topical Interest Group (TIG) to determine their perceptions about and experiences with evaluation use. Responses from 282 members show agreement on the major purposes of evaluation and an increased use of performance-results oriented and formative evaluations. (SLD)

  2. Results of User Satisfaction Surveys for 18 buildings, 3rd Draft

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Heiselberg, Per

    This report is prepared to assemble and to summarise all user satisfaction surveys available for buildings from Building AdVent project. The report is organised so, that results for each building presented in a separate chapter. Moreover, the report is divided into six parts, these are, as follow...

  3. Double-theodolite measurement system used in the image calibration of space photographic instrument

    Institute of Scientific and Technical Information of China (English)

    LI Yan; QIAO Yan-feng; SU Wan-xin; LIU Ze-xun

    2005-01-01

    The purpose of characterizing the image of space photographic instrument is to gain the space included angles from three coordinate axes in the three-dimensional coordinate of the image and the directionality of the three axes of coordinate in the frame of axes of the instrument. The two reference frames will keep in the same direction finally by adjusting according to space angles. This problem was solved by a new high-precision measurement system composed of a double-theodolite and a set of communication system. In the survey system, two TDA5005 total stations from Leica Company will be selected as the double-theodolite and the interdependence of both coordinate systems can be achieved by moving the stations only at one time. Therefore, this measurement system provides a highly efficient and high-precision surveying method to the image calibration of the space photographic instrument. According to the experiment, its measuring accuracy can reach arc-second level.

  4. [Recovery Self Assessment: Translation and cultural adaption of a recovery oriented assessment instrument].

    Science.gov (United States)

    Zuaboni, Gianfranco; Degano Kieser, Luciana; Kozel, Bernd; Glavanovits, Katharina; Utschakowski, Jörg; Behrens, Johann

    2015-08-01

    The recovery approach is becoming increasingly important in mental health services and research. In English-speaking countries, its practical implementation as well as the scientific discussion is far more advanced. To support the approach, assessment instruments are required. A widespread and recognised tool is the Recovery Self Assessment Scale {RSA}. This includes four versions of a questionnaire, which cover the perspectives of users, providers, family members and management. In this article, the development of the instrument and the system atictranslation process are presented. Two independent research groups applied different translation. The Swiss research group {AGS} used the ISOPR principles, the German research group (AGN} the Guidelines of the European Social Survey Programme for survey translations TRAPD. The methods differ in the fact,that TRAPD uses focus groups. The results of both groups were combined by means of a consensus process. Within the translation and cultural adjustment of the RSA-D, the the oretical framework of the RSA as well as the transferability into the German speaking context has been ensured. Before the RSA-D c~n beused in practice and research, further studies towards psychometric testing should be conducted.

  5. The Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI: design, execution, and early results

    Directory of Open Access Journals (Sweden)

    A. J. M. Piters

    2012-02-01

    Full Text Available From June to July 2009 more than thirty different in-situ and remote sensing instruments from all over the world participated in the Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI. The campaign took place at KNMI's Cabauw Experimental Site for Atmospheric Research (CESAR in the Netherlands. Its main objectives were to determine the accuracy of state-of-the-art ground-based measurement techniques for the detection of atmospheric nitrogen dioxide (both in-situ and remote sensing, and to investigate their usability in satellite data validation. The expected outcomes are recommendations regarding the operation and calibration of such instruments, retrieval settings, and observation strategies for the use in ground-based networks for air quality monitoring and satellite data validation. Twenty-four optical spectrometers participated in the campaign, of which twenty-one had the capability to scan different elevation angles consecutively, the so-called Multi-axis DOAS systems, thereby collecting vertical profile information, in particular for nitrogen dioxide and aerosol. Various in-situ samplers and lidar instruments simultaneously characterized the variability of atmospheric trace gases and the physical properties of aerosol particles. A large data set of continuous measurements of these atmospheric constituents has been collected under various meteorological conditions and air pollution levels. Together with the permanent measurement capability at the CESAR site characterizing the meteorological state of the atmosphere, the CINDI campaign provided a comprehensive observational data set of atmospheric constituents in a highly polluted region of the world during summertime. First detailed comparisons performed with the CINDI data show that slant column measurements of NO2, O4 and HCHO with MAX-DOAS agree within 5 to 15%, vertical profiles of NO2 derived from several independent

  6. Radiological verification survey results at 14 Peck Ave., Pequannock, New Jersey (PJ001V)

    International Nuclear Information System (INIS)

    Rodriguez, R.E.; Johnson, C.A.

    1995-05-01

    The U.S. Department of Energy (DOE) conducted remedial action during 1993 at the Pompton Plains Railroad Spur and eight vicinity properties in the Wayne and Pequannock Townships in New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Wayne Interim Storage Site (WISS), formerly the W. R. Grace facility. The property at 14 Peck Ave., Pequannock, New Jersey is one of these vicinity properties. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey at this property. The purpose of the survey, conducted between September and December 1993, was to confirm the success of the remedial actions performed to remove any radioactive materials in excess of the identified guidelines. The verification survey included surface gamma scans and gamma readings at 1 meter, beta-gamma scans, and the collection of soil and debris samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at 14 Peck Ave. were within applicable DOE guidelines. Based on the results of the remedial action data and confirmed by the verification survey data, the portions of the site that had been remediated during this action successfully meet the DOE remedial action objectives

  7. Radiological verification survey results at 3 Peck Ave., Pequannock, New Jersey (PJ002V)

    International Nuclear Information System (INIS)

    Rodriguez, R.E.; Johnson, C.A.

    1995-05-01

    The US Department of Energy (DOE) conducted remedial action during 1993 at the Pompton Plains Railroad Spur and eight vicinity properties in the Wayne and Pequannock Townships in New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Wayne Interim Storage Site (WISS), formerly the W.R. Grace facility. The property at 3 Peck Ave., Pequannock, New Jersey is one of these vicinity properties. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey at this property. The purpose of the survey, conducted between September and December 1993, was to confirm the success of the remedial actions performed to remove any radioactive materials in excess of the identified guidelines. The verification survey included surface gamma scans and gamma readings at 1 meter, beta-gamma scans, and the collection of soil and debris samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at 3 Peck Ave. were within applicable DOE guidelines. Based on the results of the remedial action data and confirmed by the verification survey data, the portions of the site that had been remediated during this action successfully meet the DOE remedial action objectives

  8. Radiological verification survey results at 15 Peck Ave., Pequannock, New Jersey (PJ005V)

    International Nuclear Information System (INIS)

    Rodriguez, R.E.; Johnson, C.A.

    1995-05-01

    The US Department of Energy (DOE) conducted remedial action during 1993 at the Pompton Plains Railroad Spur and eight vicinity properties in the Wayne and Pequannock Townships in New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Wayne Interim Storage Site (WISS), formerly the W.R. Grace facility. The property at 15 Peck Ave., Pequannock, New Jersey is one of these vicinity properties. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey at this property. The purpose of the survey, conducted between September and December 1993, was to confirm the success of the remedial actions performed to remove any radioactive materials in excess of the identified guidelines. The verification survey included surface gamma scans and gamma readings at 1 meter, beta-gamma scans, and the collection of soil and debris samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at 15 Peck Ave. were within applicable DOE guidelines. Based on the results of the remedial action data and confirmed by the verification survey data, the portions of the site that had been remediated during this action successfully meet the DOE remedial action objectives

  9. Radiological verification survey results at 17 Peck Ave., Pequannock, New Jersey (PJ006V)

    International Nuclear Information System (INIS)

    Rodriguez, R.E.; Johnson, C.A.

    1995-05-01

    The US Department of Energy (DOE) conducted remedial action during 1993 at the Pompton Plains Railroad Spur and eight vicinity properties in the Wayne and Pequannock Townships in New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Wayne Interim Storage Site (WISS), formerly the W.R. Grace facility. The property at 17 Peck Ave., Pequannock, New Jersey is one of these vicinity properties. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey at this property. The purpose of the survey, conducted between September and December 1993, was to confirm the success of the remedial actions performed to remove any radioactive materials in excess of the identified guidelines. The verification survey included surface gamma scans and gamma readings at 1 meter, beta-gamma scans, and the collection of soil and debris samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at 17 Peck Ave. were within applicable DOE guidelines. Based on the results of the remedial action data and confirmed by the verification survey data, the portions of the site that had been remediated during this action successfully meet the DOE remedial action objectives

  10. Radiological verification survey results at 7 Peck Ave., Pequannock, New Jersey (PJ003V)

    International Nuclear Information System (INIS)

    Rodriguez, R.E.; Johnson, C.A.

    1995-05-01

    The US Department of Energy (DOE) conducted remedial action during 1993 at the Pompton Plains Railroad Spur and eight vicinity properties in the Wayne and Pequannock Townships in New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Wayne Interim Storage Site (WISS), formerly the W.R. Grace facility. The property at 7 Peck Ave., Pequannock, New Jersey is one of these vicinity properties. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey at this property. The purpose of the survey, conducted between September and December 1993, was to confirm the success of the remedial actions performed to remove any radioactive materials in excess of the identified guidelines. The verification survey included surface gamma scans and gamma readings at 1 meter, beta-gamma scans, and the collection of soil samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at 7 Peck Ave. were within applicable DOE guidelines. Based on the results of the remedial action data and confirmed by the verification survey data, the portions of the site that had been remediated during this action successfully meet the DOE remedial action objectives

  11. Radiological verification survey results as 13 Peck Ave., Pequannock, New Jersey (PJ004V)

    International Nuclear Information System (INIS)

    Rodriguez, R.E.; Johnson, C.A.

    1995-05-01

    The US Department of Energy (DOE) conducted remedial action during 1993 at the Pompton Plains Railroad Spur and eight vicinity properties in the Wayne and Pequannock Townships in New Jersey as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are in the vicinity of the DOE-owned Wayne Interim Storage Site (WISS), formerly the W.R. Grace facility. The property at 13 Peck Ave., Pequannock, New Jersey is one of these vicinity properties. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey at this property. The purpose of the survey, conducted between September and December 1993, was to confirm the success of the remedial actions performed to remove any radioactive materials in excess of the identified guidelines. The verification survey included surface gamma scans and gamma readings at 1 meter, beta-gamma scans, and the collection of soil and debris samples for radionuclide analysis. Results of the survey demonstrated that all radiological measurements on the property at 13 Peck Ave. were within applicable DOE guidelines. Based on the results of the remedial action data and confirmed by the verification survey data, the portions of the site that had been remediated during this action successfully meet the DOE remedial action objectives

  12. Uncertainty of Blood Alcohol Concentration (BAC Results as Related to Instrumental Conditions: Optimization and Robustness of BAC Analysis Headspace Parameters

    Directory of Open Access Journals (Sweden)

    Haleigh A. Boswell

    2015-12-01

    Full Text Available Analysis of blood alcohol concentration is a routine analysis performed in many forensic laboratories. This analysis commonly utilizes static headspace sampling, followed by gas chromatography combined with flame ionization detection (GC-FID. Studies have shown several “optimal” methods for instrumental operating conditions, which are intended to yield accurate and precise data. Given that different instruments, sampling methods, application specific columns and parameters are often utilized, it is much less common to find information on the robustness of these reported conditions. A major problem can arise when these “optimal” conditions may not also be robust, thus producing data with higher than desired uncertainty or potentially inaccurate results. The goal of this research was to incorporate the principles of quality by design (QBD in the adjustment and determination of BAC (blood alcohol concentration instrumental headspace parameters, thereby ensuring that minor instrumental variations, which occur as a matter of normal work, do not appreciably affect the final results of this analysis. This study discusses both the QBD principles as well as the results of the experiments, which allow for determination of more favorable instrumental headspace conditions. Additionally, method detection limits will also be reported in order to determine a reporting threshold and the degree of uncertainty at the common threshold value of 0.08 g/dL. Furthermore, the comparison of two internal standards, n-propanol and t-butanol, will be investigated. The study showed that an altered parameter of 85 °C headspace oven temperature and 15 psi headspace vial pressurization produces the lowest percent relative standard deviation of 1.3% when t-butanol is implemented as an internal standard, at least for one very common platform. The study also showed that an altered parameter of 100 °C headspace oven temperature and 15-psi headspace vial pressurization

  13. Radiotherapy for Graves' orbitopathy: results of a national survey

    International Nuclear Information System (INIS)

    Heyd, R.; Zamboglou, N.; Heinrich Seegenschmiedt, M.; Strassmann, G.; Micke, O.; Makoski, H.B.

    2003-01-01

    Background: Graves' orbitopathy (GO) is a widely accepted indication for radiation therapy (RT). In conjunction with the German Cooperative Group on Radiotherapy for Benign Diseases (GCG-BD), a national survey was conducted in order to assess whether or not there is a consensus on the indication for RT and various treatment factors which were studied. Material and Methods: A questionnaire was circulated to 190 RT institutions to obtain relevant data concerning the patients' workload, stage-dependent indication, and diagnostic procedures, which were considered to be necessary. Further questions addressed details on radiation technique and dose-fractionation schedules, the combined use of corticoids, and salvage RT after previous treatment failure following RT. Results: With a response rate of 152/190 (80%), the survey is nationally representative. Based on the case workload, an estimated annual number of 1,600 GO cases are treated in German radiotherapy departments. With an 88% consensus, stages II-V are the typical indications. 85% considered imaging studies necessary for indication and only 48% for laboratory tests. 76% of the institutions used total doses in the range of 15-20 Gy, and conventional fractionation was most common (57%). 82% used a face mask fixation and 67% CT-based treatment planning. Approximately 50% would prescribe salvage RT, and total doses in the range of 20-40 Gy were considered to be acceptable. Conclusions: The survey revealed a consensus concerning most of the factors studied. We recommend to review the patterns of care for RT of other entities of benign diseases and to implement a quality assurance program both on national and international levels. (orig.)

  14. Stigma in Canada: Results From a Rapid Response Survey

    Science.gov (United States)

    Stuart, Heather; Patten, Scott B; Koller, Michelle; Modgill, Geeta; Liinamaa, Tiina

    2014-01-01

    Objective: Our paper presents findings from the first population survey of stigma in Canada using a new measure of stigma. Empirical objectives are to provide a descriptive profile of Canadian’s expectations that people will devalue and discriminate against someone with depression, and to explore the relation between experiences of being stigmatized in the year prior to the survey among people having been treated for a mental illness with a selected number of sociodemographic and mental health–related variables. Method: Data were collected by Statistics Canada using a rapid response format on a representative sample of Canadians (n = 10 389) during May and June of 2010. Public expectations of stigma and personal experiences of stigma in the subgroup receiving treatment for a mental illness were measured. Results: Over one-half of the sample endorsed 1 or more of the devaluation discrimination items, indicating that they believed Canadians would stigmatize someone with depression. The item most frequently endorsed concerned employers not considering an application from someone who has had depression. Over one-third of people who had received treatment in the year prior to the survey reported discrimination in 1 or more life domains. Experiences of discrimination were strongly associated with perceptions that Canadians would devalue someone with depression, younger age (12 to 15 years), and self-reported poor general mental health. Conclusions: The Mental Health Experiences Module reflects an important partnership between 2 national organizations that will help Canada fulfill its monitoring obligations under the United Nations Convention on the Rights of Persons with Disabilities and provide a legacy to researchers and policy-makers who are interested in monitoring changes in stigma over time. PMID:25565699

  15. Restricted working hours in Austrian residency programs : Survey results.

    Science.gov (United States)

    Bergmeister, Konstantin D; Aman, Martin; Podesser, Bruno K

    2018-04-27

    New regulations for working hours of medical doctors have been implemented in Austria based on the European directive 2003/88/EG, limiting on-duty working hours to 48 h per week. Clinical work is, therefore, substantially reduced compared to previous decades, and little is known on physician and students' opinions on this matter. We illustrate survey results concerning on-job training, its difficulties, and implications for restricted working hours. We conducted an internal survey among M.D. and Ph.D. students and medical staff members at the Medical University of Vienna using the MedCampus system (CAMPUSOnline, Graz, Austria) and SPSS (V.21, IBM Corp, Armonk, NY, USA). Participants were 36.5% staff members and 63.5% students. Students rated continuous education of physicians high at 9.19 ± 1.76 and staff members at 8.90 ± 2.48 on a 1-10 (1 unimportant, 10 most important) scale. Students rated limited time resources, while staff considered financial resources as the greatest challenge for in-hospital education. Overall, 28.85% thought that restricted working hours can positively influence education, while 19.04% thought the opposite and 52.11% were undecided. Considering the limited available time and financial resources, education of tomorrow's medical doctors remains an important but difficult task. While participants of our survey rated education as very important despite its many challenges, the opinions towards limited working hours were not as clear. Given that over 50% are still undecided whether reduced work hours may also positively influence medical education, it clearly presents an opportunity to include the next generations of physicians in this undertaking.

  16. Development and evaluation of a new survey instrument to measure the quality of colorectal cancer screening decisions.

    Science.gov (United States)

    Sepucha, Karen R; Feibelmann, Sandra; Cosenza, Carol; Levin, Carrie A; Pignone, Michael

    2014-08-20

    Guidelines for colorectal cancer screening recommend that patients be informed about options and be able to select preferred method of screening; however, there are no existing measures available to assess whether this happens. Colorectal Cancer Screening Decision Quality Instrument (CRC-DQI) includes knowledge items and patients' goals and concerns. Items were generated through literature review and qualitative work with patients and providers. Hypotheses relating to the acceptability, feasibility, discriminant validity and retest reliability of the survey were examined using data from three studies: (1) 2X2 randomized study of participants recruited online, (2) cross-sectional sample of patients recruited in community health clinics, and (3) cross-sectional sample of providers recruited from American Medical Association Master file. 338 participants were recruited online, 94 participants were recruited from community health centers, and 115 physicians were recruited. The CRC-DQI was feasible and acceptable with low missing data and high response rates for both online and paper-based administrations. The knowledge score was able to discriminate between those who had seen a decision aid or not (84% vs. 64%, p quality decisions about colon cancer screening.

  17. Final Report - Independent Confirmatory Survey Summary and Results for the Hematite Decommissioning Project, Festus, Missouri

    International Nuclear Information System (INIS)

    Bailey, E.N.

    2009-01-01

    The objectives of the confirmatory surveys were to provide independent contractor field data reviews and to generate independent radiological data for use by the NRC in evaluating the adequacy and accuracy of the licensee's procedures and survey results.

  18. Bulletin Survey - Early Results

    CERN Multimedia

    2002-01-01

    There was a good response to our questionnaire on the Bulletin (around 450 so far). Many thanks to all of you - your views are invaluable to us. Pending publication of the full figures, which will give latecomers time to take part in the survey, here we give here answers some of your most frequent comments. Thank you for the many warm tributes and messages of encouragement we received. We also received criticisms about the way information is handled in the Bulletin and on its circulation. In today's issue we reply to these two points. Why is the Bulletin politically correct ? Many respondents reproach the Bulletin for a lack of objectivity and for being too politically correct to the point of being a propaganda organ. It is true that the Bulletin is not a newspaper, but rather a bulletin of communication (like SLAC's Beam Line). What is the difference ? A newspaper is objectively independent of the subjects it reports on, and when its reporters write stories they dig around for information from all parties...

  19. The Einstein/CFA stellar survey - Overview of the data and interpretation of results

    Science.gov (United States)

    Vaiana, G. S.

    1981-01-01

    Results are presented from an extensive survey of stellar X-ray emission, using the Einstein Observatory. Over 140 stars have been detected to date, throughout the H-R diagram, thus showing that soft X-ray emission is the norm rather than the exception for stars in general. This finding is strongly at odds with pre-Einstein expectations based on standard acoustic theories of coronal heating. Typical examples of stellar X-ray detections and an overview of the survey data are presented. In combination with recent results from solar X-ray observations, the new Einstein data argue for the general applicability of magnetic field-related coronal heating mechanisms.

  20. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards